Sample records for interlaboratory comparison program

  1. POTENTIAL RADIOACTIVE POLLUTANTS RESULTING FROM EXPANDED ENERGY PROGRAMS

    EPA Science Inventory

    An effective environmental monitoring program must have a quality assurance component to assure the production of valid data. Quality assurance has many components: calibration standards, standard reference materials, standard reference methods, interlaboratory comparison studies...

  2. Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES.

    PubMed

    Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika

    2005-12-01

    The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.

  3. External quality-assurance programs managed by the U.S. Geological Survey in support of the National Atmospheric Deposition Program/National Trends Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2005-01-01

    The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.

  4. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  5. External Quality Assurance Programs Managed by the U.S. Geological Survey in Support of the National Atmospheric Deposition Program/Mercury Deposition Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2007-01-01

    The U.S. Geological Survey (USGS) Branch of Quality Systems operates external quality assurance programs for the National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Beginning in 2004, three programs have been implemented: the system blank program, the interlaboratory comparison program, and the blind audit program. Each program was designed to measure error contributed by specific components in the data-collection process. The system blank program assesses contamination that may result from sampling equipment, field exposure, and routine handling and processing of the wet-deposition samples. The interlaboratory comparison program evaluates bias and precision of analytical results produced by the Mercury Analytical Laboratory (HAL) for the NADP/MDN, operated by Frontier GeoSciences, Inc. The HAL's performance is compared with the performance of five other laboratories. The blind audit program assesses bias and variability of MDN data produced by the HAL using solutions disguised as environmental samples to ascertain true laboratory performance. This report documents the implementation of quality assurance procedures for the NADP/MDN and the operating procedures for each of the external quality assurance programs conducted by the USGS. The USGS quality assurance information provides a measure of confidence to NADP/MDN data users that measurement variability is distinguished from environmental signals.

  6. Role and Evaluation of Interlaboratory Comparison Results in Laboratory Accreditation

    NASA Astrophysics Data System (ADS)

    Bode, P.

    2008-08-01

    Participation in interlaboratory comparisons provides laboratories an opportunity for independent assessment of their analytical performance, both in absolute way and in comparison with those by other techniques. However, such comparisons are hindered by differences in the way laboratories participate, e.g. at best measurement capability or under routine conditions. Neutron activation analysis laboratories, determining total mass fractions, often see themselves classified as `outliers' since the majority of other participants employ techniques with incomplete digestion methods. These considerations are discussed in relation to the way results from interlaboratory comparisons are evaluated by accreditation bodies following the requirements of Clause 5.9.1 of the ISO/IEC 17025:2005. The discussion and conclusions come largely forth from experiences in the author's own laboratory.

  7. Inter-Laboratory Comparison for Calibration of Relative Humidity Devices Among Accredited Laboratories in Malaysia

    NASA Astrophysics Data System (ADS)

    Hussain, F.; Khairuddin, S.; Othman, H.

    2017-01-01

    An inter-laboratory comparison in relative humidity measurements among accredited laboratories has been coordinated by the National Metrology Institute of Malaysia. It was carried out to determine the performance of the participating laboratories. The objective of the comparison was to acknowledge the participating laboratories competencies and to verify the level of accuracies declared in their scope of accreditation, in accordance with the MS ISO/IEC 17025 accreditation. The measurement parameter involved was relative humidity for the range of 30-90 %rh at a nominal temperature of 50°C. Eight accredited laboratories participated in the inter-laboratory comparison. Two units of artifacts have been circulated among the participants as the transfer standards.

  8. External quality assurance project report for the National Atmospheric Deposition Program’s National Trends Network and Mercury Deposition Network, 2015–16

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn

    2018-06-29

    The U.S. Geological Survey Precipitation Chemistry Quality Assurance project operated five distinct programs to provide external quality assurance monitoring for the National Atmospheric Deposition Program’s (NADP) National Trends Network and Mercury Deposition Network during 2015–16. The National Trends Network programs include (1) a field audit program to evaluate sample contamination and stability, (2) an interlaboratory comparison program to evaluate analytical laboratory performance, and (3) a colocated sampler program to evaluate bias and variability attributed to automated precipitation samplers. The Mercury Deposition Network programs include the (4) system blank program and (5) an interlaboratory comparison program. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends for chemical constituents in wet deposition.The field audit program results indicate increased sample contamination for calcium, magnesium, and potassium relative to 2010 levels, and slight fluctuation in sodium contamination. Nitrate contamination levels dropped slightly during 2014–16, and chloride contamination leveled off between 2007 and 2016. Sulfate contamination is similar to the 2000 level. Hydrogen ion contamination has steadily decreased since 2012. Losses of ammonium and nitrate resulting from potential sample instability were negligible.The NADP Central Analytical Laboratory produced interlaboratory comparison results with low bias and variability compared to other domestic and international laboratories that support atmospheric deposition monitoring. Significant absolute bias above the magnitudes of the detection limits was observed for nitrate and sulfate concentrations, but no analyte determinations exceeded the detection limits for blanks.Colocated sampler program results from dissimilar colocated collectors indicate that the retrofit of the National Trends Network with N-CON Systems Company, Inc. precipitation collectors could cause substantial shifts in NADP annual deposition (concentration multiplied by depth) values. Median weekly relative percent differences for analyte concentrations ranged from -4 to +76 percent for cations, from 5 to 6 percent for ammonium, from +14 to +25 percent for anions, and from -21 to +8 percent for hydrogen ion contamination. By comparison, weekly absolute concentration differences for paired identical N-CON Systems Company, Inc., collectors ranged from 4–22 percent for cations; 2–9 percent for anions; 4–5 percent for ammonium; and 13–14 percent for hydrogen ion contamination. The N-CON Systems Company, Inc. collector caught more precipitation than the Aerochem Metrics Model 301 collector (ACM) at the WA99/99WA sites, but it typically caught slightly less precipitation than the ACM at ND11/11ND, sites which receive more wind and snow than WA99/99WA.Paired, identical OTT Pluvio-2 and ETI Noah IV precipitation gages were operated at the same sites. Median absolute percent differences for daily measured precipitation depths ranged from 0 to 7 percent. Annual absolute differences ranged from 0.08 percent (ETI Noah IV precipitation gages) to 11 percent (OTT Pluvio-2 precipitation gages).The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicate that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations (1.098 nanograms per liter; ng/L). The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring. The laboratory’s performance results indicate a +1-ng/L shift in bias between 2015 (-0.4 ng/L) and 2016 (+0.5 ng/L).

  9. How consistent are we? Inter-laboratory comparison for male fathead minnows exposed to 17α-ethinylestradiol

    EPA Science Inventory

    Transcriptomic approaches are widely used to examine effects of aquatic contaminants in both laboratory and field studies. Fundamental questions remain however for defining the limits of the technology and how it may be used in environmental monitoring programs. Uncertainties exi...

  10. INTERLABORATORY COMPARISON STUDIES FOR CHARACTERIZATION OF ORGANIC COMPOUNDS IN PARTICULATE MATTER

    EPA Science Inventory

    A working group of investigators, who are characterizing and quantifying the organic compounds in particulate matter (PM) as part of the US EPA's PM 2.5 research program and related studies, was established three years ago to advance the quality and comparability of data on the...

  11. External quality-assurance results for the National Atmospheric Deposition Program and the National Trends Network during 1986

    USGS Publications Warehouse

    See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1988-01-01

    During 1986, the U.S. Geological Survey operated three programs to provide external quality-assurance monitoring of the National Atmospheric Deposition Program and National Trends Network. An intersite-comparison program was used to assess the accuracy of onsite pH and specific-conductance determinations at quarterly intervals. The blind-audit program was used to assess the effect of routine sample handling on the precision and bias of program and network wet-deposition data. Analytical results from four laboratories, which routinely analyze wet-deposition samples, were examined to determine if differences existed between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. An average of 78 and 89 percent of the site operators participating in the intersite-comparison met the network goals for pH and specific conductance. A comparison of analytical values versus actual values for samples submitted as part of the blind-audit program indicated that analytical values were slightly but significantly (a = 0.01) larger than actual values for pH, magnesium, sodium, and sulfate; analytical values for specific conductance were slightly less than actual values. The decreased precision in the analyses of blind-audit samples when compared to interlaboratory studies indicates that a large amount of uncertainty in network deposition data may be a result of routine field operations. The results of the interlaboratory comparison study indicated that the magnitude of the difference between laboratory analyses was small for all analytes. Analyses of deionized, distilled water blanks by participating laboratories indicated that the laboratories had difficulty measuring analyte concentrations near their reported detection limits. (USGS)

  12. INTERLABORATORY COMPARISON OF A REDUCED VOLUME MARINE SEDIMENT TOXICITY TEST METHOD USING AMPHIPOD AMPELISCA ABDITA

    EPA Science Inventory

    The U.S. Environmental Protection Agency has standardized methods for performing acute marine amphipod sediment toxicity tests. A test design reducing sediment volume from 200 to 50 ml and overlying water from 600 to 150 ml was recently proposed. An interlaboratory comparison wa...

  13. External quality-assurance results for the National Atmospheric Deposition Program / National Trends Network and Mercury Deposition Network, 2004

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Latysh, Natalie E.; Greene, Shannon M.

    2006-01-01

    The U.S. Geological Survey (USGS) used five programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) and two programs to provide external quality-assurance monitoring for the NADP/Mercury Deposition Network (NADP/MDN) during 2004. An intersite-comparison program was used to estimate accuracy and precision of field-measured pH and specific-conductance. The variability and bias of NADP/NTN data attributed to field exposure, sample handling and shipping, and laboratory chemical analysis were estimated using the sample-handling evaluation (SHE), field-audit, and interlaboratory-comparison programs. Overall variability of NADP/NTN data was estimated using a collocated-sampler program. Variability and bias of NADP/MDN data attributed to field exposure, sample handling and shipping, and laboratory chemical analysis were estimated using a system-blank program and an interlaboratory-comparison program. In two intersite-comparison studies, approximately 89 percent of NADP/NTN site operators met the pH measurement accuracy goals, and 94.7 to 97.1 percent of NADP/NTN site operators met the accuracy goals for specific conductance. Field chemistry measurements were discontinued by NADP at the end of 2004. As a result, the USGS intersite-comparison program also was discontinued at the end of 2004. Variability and bias in NADP/NTN data due to sample handling and shipping were estimated from paired-sample concentration differences and specific conductance differences obtained for the SHE program. Median absolute errors (MAEs) equal to less than 3 percent were indicated for all measured analytes except potassium and hydrogen ion. Positive bias was indicated for most of the measured analytes except for calcium, hydrogen ion and specific conductance. Negative bias for hydrogen ion and specific conductance indicated loss of hydrogen ion and decreased specific conductance from contact of the sample with the collector bucket. Field-audit results for 2004 indicate dissolved analyte loss in more than one-half of NADP/NTN wet-deposition samples for all analytes except chloride. Concentrations of contaminants also were estimated from field-audit data. On the basis of 2004 field-audit results, at least 25 percent of the 2004 NADP/NTN concentrations for sodium, potassium, and chloride were lower than the maximum sodium, potassium, and chloride contamination likely to be found in 90 percent of the samples with 90-percent confidence. Variability and bias in NADP/NTN data attributed to chemical analysis by the NADP Central Analytical Laboratory (CAL) were comparable to the variability and bias estimated for other laboratories participating in the interlaboratory-comparison program for all analytes. Variability in NADP/NTN ammonium data evident in 2002-03 was reduced substantially during 2004. Sulfate, hydrogen-ion, and specific conductance data reported by CAL during 2004 were positively biased. A significant (a = 0.05) bias was identified for CAL sodium, potassium, ammonium, and nitrate data, but the absolute values of the median differences for these analytes were less than the method detection limits. No detections were reported for CAL analyses of deionized-water samples, indicating that contamination was not a problem for CAL. Control charts show that CAL data were within statistical control during at least 90 percent of 2004. Most 2004 CAL interlaboratory-comparison results for synthetic wet-deposition solutions were within ?10 percent of the most probable values (MPVs) for solution concentrations except for chloride, nitrate, sulfate, and specific conductance results from one sample in November and one specific conductance result in December. Overall variability of NADP/NTN wet-deposition measurements was estimated during water year 2004 by the median absolute errors for weekly wet-deposition sample concentrations and precipitation measurements for tw

  14. INTERLABORATORY COMPARISON OF MASS SPECTROMETRIC METHODS FOR LEAD ISOTOPES AND TRACE ELEMENTS IN NIST SRM 1400 BONE ASH

    EPA Science Inventory

    The results of an interlaboratory comparison are reported for he lead isotope composition and for trace element concentrations in NIST SRM 1400 Bone Ash obtained using quadrupole and magnetic-sector inductively coupled plasma mass spectrometry (ICP-MS) and (for the Pb isotopes on...

  15. Sample Integrity Evaluation and EPA Method 325b Interlaboratory Comparison for Select Volatile Organic Compounds Collected Diffusively on Carbopack X Sorbent Tubes

    EPA Science Inventory

    Sample integrity evaluations and inter-laboratory comparisons were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A/B for monitoring benzene and additional selected volatile organic compounds (VOCs) usingpassive-diffusive Carbopack X tube sample...

  16. ORGANIC CHARACTERIZATION OF AIRBORNE PARTICLES: INTERLABORATORY COMPARISON STUDIES AND THE DEVELOPMENT OF STANDARDS AND REFERENCE MATERIALS

    EPA Science Inventory

    Investigators characterizing and quantifying the organic compounds in particulate matter (PM) have completed the second interlaboratory comparison study. The first study used a subset of SRM1649a sieved to <63um(API) as an unknown sample, an extract of API, and SRM1649a for u...

  17. External quality assurance project report for the National Atmospheric Deposition Program’s National Trends Network and Mercury Deposition Network, 2013–14

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn

    2016-07-05

    The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicated that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations. The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring.

  18. Making the Case for Objective Performance Metrics in Newborn Screening by Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Rinaldo, Piero; Zafari, Saba; Tortorelli, Silvia; Matern, Dietrich

    2006-01-01

    The expansion of newborn screening programs to include multiplex testing by tandem mass spectrometry requires understanding and close monitoring of performance metrics. This is not done consistently because of lack of defined targets, and interlaboratory comparison is almost nonexistent. Between July 2004 and April 2006 (N = 176,185 cases), the…

  19. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    EPA Science Inventory

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practica...

  20. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    EPA Science Inventory

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical...

  1. External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network during 1991

    USGS Publications Warehouse

    Nilles, M.A.; Gordon, J.D.; Schroder, L.J.; Paulin, C.E.

    1995-01-01

    The U.S. Geological Survey used four programs in 1991 to provide external quality assurance for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). An intersite-comparison program was used to evaluate onsite pH and specific-conductance determinations. The effects of routine sample handling, processing, and shipping of wet-deposition samples on analyte determinations and an estimated precision of analyte values and concentrations were evaluated in the blind-audit program. Differences between analytical results and an estimate of the analytical precision of four laboratories routinely measuring wet deposition were determined by an interlaboratory-comparison program. Overall precision estimates for the precipitation-monitoring system were determined for selected sites by a collocated-sampler program. Results of the intersite-comparison program indicated that 93 and 86 percent of the site operators met the NADP/NTN accuracy goal for pH determinations during the two intersite-comparison studies completed during 1991. The results also indicated that 96 and 97 percent of the site operators met the NADP/NTN accuracy goal for specific-conductance determinations during the two 1991 studies. The effects of routine sample handling, processing, and shipping, determined in the blind-audit program indicated significant positive bias (a=.O 1) for calcium, magnesium, sodium, potassium, chloride, nitrate, and sulfate. Significant negative bias (or=.01) was determined for hydrogen ion and specific conductance. Only ammonium determinations were not biased. A Kruskal-Wallis test indicated that there were no significant (*3t=.01) differences in analytical results from the four laboratories participating in the interlaboratory-comparison program. Results from the collocated-sampler program indicated the median relative error for cation concentration and deposition exceeded eight percent at most sites, whereas the median relative error for sample volume, sulfate, and nitrate concentration at all sites was less than four percent. The median relative error for hydrogen ion concentration and deposition ranged from 4.6 to 18.3 percent at the four sites and as indicated in previous years of the study, was inversely proportional to the acidity of the precipitation at a given site. Overall, collocated-sampling error typically was five times that of laboratory error estimates for most analytes.

  2. Toward the Standardization of Biochar Analysis: The COST Action TD1107 Interlaboratory Comparison.

    PubMed

    Bachmann, Hans Jörg; Bucheli, Thomas D; Dieguez-Alonso, Alba; Fabbri, Daniele; Knicker, Heike; Schmidt, Hans-Peter; Ulbricht, Axel; Becker, Roland; Buscaroli, Alessandro; Buerge, Diane; Cross, Andrew; Dickinson, Dane; Enders, Akio; Esteves, Valdemar I; Evangelou, Michael W H; Fellet, Guido; Friedrich, Kevin; Gasco Guerrero, Gabriel; Glaser, Bruno; Hanke, Ulrich M; Hanley, Kelly; Hilber, Isabel; Kalderis, Dimitrios; Leifeld, Jens; Masek, Ondrej; Mumme, Jan; Carmona, Marina Paneque; Calvelo Pereira, Roberto; Rees, Frederic; Rombolà, Alessandro G; de la Rosa, José Maria; Sakrabani, Ruben; Sohi, Saran; Soja, Gerhard; Valagussa, Massimo; Verheijen, Frank; Zehetner, Franz

    2016-01-20

    Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical-chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future.

  3. Interlaboratory comparison of chemical analysis of uranium mononitride

    NASA Technical Reports Server (NTRS)

    Merkle, E. J.; Davis, W. F.; Halloran, J. T.; Graab, J. W.

    1974-01-01

    Analytical methods were established in which the critical variables were controlled, with the result that acceptable interlaboratory agreement was demonstrated for the chemical analysis of uranium mononitride. This was accomplished by using equipment readily available to laboratories performing metallurgical analyses. Agreement among three laboratories was shown to be very good for uranium and nitrogen. Interlaboratory precision of + or - 0.04 percent was achieved for both of these elements. Oxygen was determined to + or - 15 parts per million (ppm) at the 170-ppm level. The carbon determination gave an interlaboratory precision of + or - 46 ppm at the 320-ppm level.

  4. Results of interlaboratory comparison of fission track ages for 1992 fission track workshop

    USGS Publications Warehouse

    Miller, D.S.; Crowley, K.D.; Dokka, R.K.; Galbraith, R.F.; Kowallis, B.J.; Naeser, C.W.

    1993-01-01

    Two apatites and one sphene were made available to the fission track research community for analysis prior to the 1992 Fission Track Workshop held in Philadelphia, U.S.A., 13-17 July. Eighteen laboratories throughout the world received aliquots of apatite and sphene. To date, analyses by 33 different scientists have been representing 15 different laboratories. With respect to the previous two interlaboratory comparisons, there is a noticeable improvement in the accuracy of the age results (Naeser and Cebula, 1978; Naeser et al., 1981; Miller et al., 1985;Miller et al.1990). Ninety-four percent of the analysis used the external detector method (EDM) combined with the zeta technique while the remaining individuals used the population method (POP). Track length measurements (requested for the first time in the interlaboratory comparison studies) were in relatively good agreement. ?? 1993.

  5. An interlaboratory comparison of sediment elutriate preparation and toxicity test methods

    EPA Science Inventory

    Elutriate bioassays are among numerous methods that exist for assessing the potential toxicity of sediments in aquatic systems. In this study, interlaboratory results were compared from 96-hour Ceriodaphnia dubia and Pimephales promelas static-renewal acute toxicity tests conduct...

  6. Harmonizing lipidomics: NIST interlaboratory comparison exercise for lipidomics using SRM 1950-Metabolites in Frozen Human Plasma.

    PubMed

    Bowden, John A; Heckert, Alan; Ulmer, Candice Z; Jones, Christina M; Koelmel, Jeremy P; Abdullah, Laila; Ahonen, Linda; Alnouti, Yazen; Armando, Aaron M; Asara, John M; Bamba, Takeshi; Barr, John R; Bergquist, Jonas; Borchers, Christoph H; Brandsma, Joost; Breitkopf, Susanne B; Cajka, Tomas; Cazenave-Gassiot, Amaury; Checa, Antonio; Cinel, Michelle A; Colas, Romain A; Cremers, Serge; Dennis, Edward A; Evans, James E; Fauland, Alexander; Fiehn, Oliver; Gardner, Michael S; Garrett, Timothy J; Gotlinger, Katherine H; Han, Jun; Huang, Yingying; Neo, Aveline Huipeng; Hyötyläinen, Tuulia; Izumi, Yoshihiro; Jiang, Hongfeng; Jiang, Houli; Jiang, Jiang; Kachman, Maureen; Kiyonami, Reiko; Klavins, Kristaps; Klose, Christian; Köfeler, Harald C; Kolmert, Johan; Koal, Therese; Koster, Grielof; Kuklenyik, Zsuzsanna; Kurland, Irwin J; Leadley, Michael; Lin, Karen; Maddipati, Krishna Rao; McDougall, Danielle; Meikle, Peter J; Mellett, Natalie A; Monnin, Cian; Moseley, M Arthur; Nandakumar, Renu; Oresic, Matej; Patterson, Rainey; Peake, David; Pierce, Jason S; Post, Martin; Postle, Anthony D; Pugh, Rebecca; Qiu, Yunping; Quehenberger, Oswald; Ramrup, Parsram; Rees, Jon; Rembiesa, Barbara; Reynaud, Denis; Roth, Mary R; Sales, Susanne; Schuhmann, Kai; Schwartzman, Michal Laniado; Serhan, Charles N; Shevchenko, Andrej; Somerville, Stephen E; St John-Williams, Lisa; Surma, Michal A; Takeda, Hiroaki; Thakare, Rhishikesh; Thompson, J Will; Torta, Federico; Triebl, Alexander; Trötzmüller, Martin; Ubhayasekera, S J Kumari; Vuckovic, Dajana; Weir, Jacquelyn M; Welti, Ruth; Wenk, Markus R; Wheelock, Craig E; Yao, Libin; Yuan, Min; Zhao, Xueqing Heather; Zhou, Senlin

    2017-12-01

    As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.

  7. Results of external quality-assurance program for the National Atmospheric Deposition Program and National Trends Network during 1985

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.

    1988-01-01

    External quality assurance monitoring of the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN) was performed by the U.S. Geological Survey during 1985. The monitoring consisted of three primary programs: (1) an intersite comparison program designed to assess the precision and accuracy of onsite pH and specific conductance measurements made by NADP and NTN site operators; (2) a blind audit sample program designed to assess the effect of routine field handling on the precision and bias of NADP and NTN wet deposition data; and (3) an interlaboratory comparison program designed to compare analytical data from the laboratory processing NADP and NTN samples with data produced by other laboratories routinely analyzing wet deposition samples and to provide estimates of individual laboratory precision. An average of 94% of the site operators participated in the four voluntary intersite comparisons during 1985. A larger percentage of participating site operators met the accuracy goal for specific conductance measurements (average, 87%) than for pH measurements (average, 67%). Overall precision was dependent on the actual specific conductance of the test solution and independent of the pH of the test solution. Data for the blind audit sample program indicated slight positive biases resulting from routine field handling for all analytes except specific conductance. These biases were not large enough to be significant for most data users. Data for the blind audit sample program also indicated that decreases in hydrogen ion concentration were accompanied by decreases in specific conductance. Precision estimates derived from the blind audit sample program indicate that the major source of uncertainty in wet deposition data is the routine field handling that each wet deposition sample receives. Results of the interlaboratory comparison program were similar to results of previous years ' evaluations, indicating that the participating laboratories produced comparable data when they analyzed identical wet deposition samples, and that the laboratory processing NADP and NTN samples achieved the best analyte precision of the participating laboratories. (Author 's abstract)

  8. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples.

    PubMed

    Kim, Sang-Bog; Roche, Jennifer

    2013-08-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  9. Inter-laboratory comparisons of hexenuronic acid measurements in kraft eucalyptus pulps using a UV-Vis spectroscopic method

    Treesearch

    J.Y. Zhu; H.F Zhou; Chai X.S.; Donna Johannes; Richard Pope; Cristina Valls; M. Blanca Roncero

    2014-01-01

    An inter-laboratory comparison of a UV-Vis spectroscopic method (TAPPI T 282 om-13 “Hexeneuronic acid content of chemical pulp”) for hexeneuronic acid measurements was conducted using three eucalyptus kraft pulps. The pulp samples were produced in a laboratory at kappa numbers of approximately 14, 20, and 35. The hexeneuronic acid contents of the three pulps were...

  10. THE DEVELOPMENT AND INTER-LABORATORY VERIFICATION OF LC-MS LIBRARIES FOR ORGANIC CHEMICALS OF ENVIRONMENTAL CONCERN

    EPA Science Inventory

    The development, verification, and comparison study between LC-MS libraries for two manufacturers’ instruments and a verified protocol are discussed. The LC-MS library protocol was verified through an inter-laboratory study that involved Federal, State, and private laboratories. ...

  11. Interlaboratory comparison program for nondestructive assay of prototype uranium reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trahey, N.M.; Smith, M.M.; Voeks, A.M.

    The US Department of Energy (DOE), New Brunswick Laboratory (NBS), designed and administered an interlaboratory comparison program based on the measurement of NBL-produced prototype uranium nondestructive assay (NDA) reference materials for scrap and waste. The objectives of the program were to evaluate the reliability of NDA techniques as applied to nuclear safeguards materials control and accountability needs and to investigate the feasibility of providing practical NDA scrap and waste reference materials for use throughout the nuclear safeguards community. Fourteen facilities representing seven DOE contractors, four US Nuclear Regulatory Commission (NRC) licensees, one EURATOM Laboratory, and NBL, participated in this program.more » Three stable, well-characterized uranium reference materials were developed and certified for this program. Synthetic calcined ash, cellulose fiber, and ion-exchange resin simulate selected uranium scrap and waste forms which are often encountered in fabrication and recovery operations. The synthetic calcined ash represents an intermediate density inorganic matrix while the cellulose fiber and ion-exchange resin are representative of low-density organic matrices. The materials, containing from 0 to 13% uranium enriched at 93% /sup 235/U, were sealed in specially selected containers. Nineteen prototype reference samples, plus three empty containers, one to accompany each set, was circulated to the participants between August 1979 and May 1984. Triplicate measurements for /sup 235/U on each of the 19 filled containers were required. In addition, participants could opt to perform modular configuration measurements using containers from Sets IIA and IIB to simulate non-homogeneously dispersed uranium in waste containers. All data were reported to NBL for evaluation.« less

  12. The determination of ethyl glucuronide in hair: Experiences from nine consecutive interlaboratory comparison rounds.

    PubMed

    Becker, R; Lô, I; Sporkert, F; Baumgartner, M

    2018-07-01

    The increasing request for hair ethyl glucuronide (HEtG) in alcohol consumption monitoring according to cut-off levels set by the Society of Hair Testing (SoHT) has triggered a proficiency testing program based on interlaboratory comparisons (ILC). Here, the outcome of nine consecutive ILC rounds organised by the SoHT on the determination of HEtG between 2011 and 2017 is summarised regarding interlaboratory reproducibility and the influence of procedural variants. Test samples prepared from cut hair (1mm) with authentic (in-vivo incorporated) and soaked (in-vitro incorporated) HEtG concentrations up to 80pg/mg were provided for 27-35 participating laboratories. Laboratory results were evaluated according to ISO 5725-5 and provided robust averages and relative reproducibility standard deviations typically between 20 and 35% in reasonable accordance with the prediction of the Horwitz model. Evaluation of results regarding the analytical techniques revealed no significant differences between gas and liquid chromatographic methods In contrast, a detailed evaluation of different sample preparations revealed significantly higher average values in case when pulverised hair is tested compared to cut hair. This observation was reinforced over the different ILC rounds and can be attributed to the increased acceptance and routine of hair pulverisation among laboratories. Further, the reproducibility standard deviations among laboratories performing pulverisation were on average in very good agreement with the prediction of the Horwitz model. Use of sonication showed no effect on the HEtG extraction yield. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Amino acid racemization dating of fossil bones, I. inter-laboratory comparison of racemization measurements

    USGS Publications Warehouse

    Bada, J.L.; Hoopes, E.; Darling, D.; Dungworth, G.; Kessels, H.J.; Kvenvolden, K.A.; Blunt, D.J.

    1979-01-01

    Enantiomeric measurements for aspartic acid, glutamic acid, and alanine in twenty-one different fossil bone samples have been carried out by three different laboratories using different analytical methods. These inter-laboratory comparisons demonstrate that D/L aspartic acid measurements are highly reproducible, whereas the enantiomeric measurements for the other amino acids show a wide variation between the three laboratories. At present, aspartic acid measurements are the most suitable for racemization dating of bone because of their superior analytical precision. ?? 1979.

  14. Interlaboratory comparison of measurements of acid-volatile sulfide and simultaneously extracted nickel in spiked sediments

    USGS Publications Warehouse

    Brumbaugh, William G.; Hammerschmidt, Chad R.; Zanella, Luciana; Rogevich, Emily; Salata, Gregory; Bolek, Radoslaw

    2011-01-01

    An interlaboratory comparison of acid-volatile sulfide (AVS) and simultaneously extracted nickel (SEM_Ni) measurements of sediments was conducted among five independent laboratories. Relative standard deviations for the seven test samples ranged from 5.6 to 71% (mean = 25%) for AVS and from 5.5 to 15% (mean = 10%) for SEM_Ni. These results are in stark contrast to a recently published study that indicated AVS and SEM analyses were highly variable among laboratories.

  15. Extra-analytical quality indicators and laboratory performances.

    PubMed

    Sciacovelli, Laura; Aita, Ada; Plebani, Mario

    2017-07-01

    In the last few years much progress has been made in raising the awareness of laboratory medicine professionals about the effectiveness of quality indicators (QIs) in monitoring, and improving upon, performances in the extra-analytical phases of the Total Testing Process (TTP). An effective system for management of QIs includes the implementation of an internal assessment system and participation in inter-laboratory comparison. A well-designed internal assessment system allows the identification of critical activities and their systematic monitoring. Active participation in inter-laboratory comparison provides information on the performance level of one laboratory with respect to that of other participating laboratories. In order to guarantee the use of appropriate QIs and facilitate their implementation, many laboratories have adopted the Model of Quality Indicators (MQI) proposed by Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of IFCC, since 2008, which is the result of international consensus and continuous experimentation, and updating to meet new, constantly emerging needs. Data from participating laboratories are collected monthly and reports describing the statistical results and evaluating laboratory data, utilizing the Six Sigma metric, issued regularly. Although the results demonstrate that the processes need to be improved upon, overall the comparison with data collected in 2014 shows a general stability of quality levels and that an improvement has been achieved over time for some activities. The continuous monitoring of QI data allows identification all possible improvements, thus highlighting the value of participation in the inter-laboratory program proposed by WG-LEPS. The active participation of numerous laboratories will guarantee an ever more significant State-of-the-Art, promote the reduction of errors and improve quality of the TTP, thus guaranteeing patient safety. Copyright © 2017. Published by Elsevier Inc.

  16. Interlaboratory comparison of real-time pcr protocols for quantification of general fecal indicator bacteria

    USGS Publications Warehouse

    Shanks, O.C.; Sivaganesan, M.; Peed, L.; Kelty, C.A.; Blackwood, A.D.; Greene, M.R.; Noble, R.T.; Bushon, R.N.; Stelzer, E.A.; Kinzelman, J.; Anan'Eva, T.; Sinigalliano, C.; Wanless, D.; Griffith, J.; Cao, Y.; Weisberg, S.; Harwood, V.J.; Staley, C.; Oshima, K.H.; Varma, M.; Haugland, R.A.

    2012-01-01

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol. ?? 2011 American Chemical Society.

  17. Results of a European interlaboratory comparison on CO2 sorption on activated carbon and coals

    NASA Astrophysics Data System (ADS)

    Gensterblum, Yves; Busch, Andreas; Krooss, Bernhard; de Weireld, Guy; Billemont, Pierre; van Hemert, Patrick; Wolf, Karl-Heinz

    2013-04-01

    For the assessment of CO2 storage in coal seams or enhanced coalbed methane production (ECBM), the sorption properties of natural coals are important parameters. Since more and more laboratories worldwide are concerned with measurements of gas sorption on coal it is indispensable to establish quality standards for such experiments. The first two interlaboratory studies on CO2 sorption on coal (Goodman et al. 2004, 2007) revealed a poor agreement of sorption isotherms among the participating laboratories, particularly in the high-pressure range. During the MOVECBM (http://www.movecbm.eu/) project funded by the European Commission (6th framework), an interlaboratory comparison of CO2 sorption on selected coals and activated carbon was initiated. Measurements were performed on dry samples at 45° C using the manometric and the gravimetric method. up to a final pressure of 15 MPa. The first set of high-pressure sorption measurements was performed on a Filtrasorb 400 activated carbon sample in order to minimise heterogeneity effects and to optimize the experimental procedures for the individual (manometric or gravimetric) methods (Gensterblum et al. 2009). Since comparability for the activated carbon was excellent, the measurements were continued using natural coals of various rank (anthracite, bituminous coal and lignite) to study the influence of heterogeneities and varying starting conditions on the CO2 sorption properties (Gensterblum et al. 2010). Compared to the poor reproducibility observed in previous interlaboratory studies (Goodman et al., 2004, 2007) this European study showed excellent agreement (<5 % deviation) among the participating laboratories with good repeatability. The sorption data and technical information on the different experimental setups have been used to investigate errors and potential pitfalls in the assessment of high-pressure CO2 sorption isotherms. References Gensterblum Y., P. van Hemert, P. Billemont, A. Busch, B.M. Krooss, G. de Weireld, D. Prinz , K.-H.A.A. Wolf, "European inter-laboratory comparison of high pressure CO2 sorption isotherms. II: natural coals" IJCG, 2010, 84, 115-124 Gensterblum Y., P. van Hemert, P. Billemont, A. Busch, D. Charriére, D. Li, B.M. Krooss, G. de Weireld, D. Prinz , K.-H.A.A. Wolf, "European inter-laboratory comparison of high pressure CO2 sorption isotherms. I: Activated carbon" Carbon 47 ( 2009 ) 2958 -2969 Goodman, A.L., Busch, A., Duffy, G., Fitzgerald, J.E., Gasem, K.A.M., Gensterblum, Y., Krooss, B.M., Levy, J., Ozdemir, E., Pan, Z., Robinson, Jr., R.L., Schroeder, K., Sudibandriyo, M., White, C. (2004). An Inter-laboratory Comparison of CO2 Isotherms Measured on Argonne Premium Coal Samples. Energy and Fuels 18, 1175-1182. Goodman, A.L., Busch, A., Day, S., Duffy, G.J., Fitzgerald, J.E., Gasem, K.A.M., Gensterblum, Y., Hartman, C., Krooss, B.M., Pan, Z., Pratt, T., Robinson, Jr., R.L., Romanov, V., Sakurovs, R., Schroeder, K., Sudibandriyo, M., White, C.M. (2007) "Inter-laboratory Comparison II: CO2 Isotherms Measured on Moisture-Equilibrated Argonne Premium Coals at 55oC and 15 MPa", International Journal of Coal Geology 72, 153-164.

  18. Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes

    NASA Astrophysics Data System (ADS)

    Oliver, Karen D.; Cousett, Tamira A.; Whitaker, Donald A.; Smith, Luther A.; Mukerjee, Shaibal; Stallings, Casson; Thoma, Eben D.; Alston, Lillian; Colon, Maribel; Wu, Tai; Henkle, Stacy

    2017-08-01

    A sample integrity evaluation and an interlaboratory comparison were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A and 325B for diffusively monitoring benzene and other selected volatile organic compounds (VOCs) using Carbopack X sorbent tubes. To evaluate sample integrity, VOC samples were refrigerated for up to 240 days and analyzed using thermal desorption/gas chromatography-mass spectrometry at the EPA Office of Research and Development laboratory in Research Triangle Park, NC, USA. For the interlaboratory comparison, three commercial analytical laboratories were asked to follow Method 325B when analyzing samples of VOCs that were collected in field and laboratory settings for EPA studies. Overall results indicate that the selected VOCs collected diffusively on sorbent tubes generally were stable for 6 months or longer when samples were refrigerated. This suggests the specified maximum 30-day storage time of VOCs collected diffusively on Carbopack X passive samplers and analyzed using Method 325B might be able to be relaxed. Interlaboratory comparison results were in agreement for the challenge samples collected diffusively in an exposure chamber in the laboratory, with most measurements within ±25% of the theoretical concentration. Statistically significant differences among laboratories for ambient challenge samples were small, less than 1 part per billion by volume (ppbv). Results from all laboratories exhibited good precision and generally agreed well with each other.

  19. Practical methodological guide for hydrometric inter-laboratory organisation

    NASA Astrophysics Data System (ADS)

    Besson, David; Bertrand, Xavier

    2015-04-01

    Discharge measurements performed by the French governmental hydrometer team feed a national database. This data is available for general river flows knowkedge, flood forecasting, low water survey, statistical calculations flow, control flow regulatory and many other uses. Regularly checking the measurements quality and better quantifying its accuracy is therefore an absolute need. The practice of inter-laboratory comparison in hydrometry particularly developed during the last decade. Indeed, discharge measurement can not easily be linked to a standard. Therefore, on-site measurement accuracy control is very difficult. Inter-laboratory comparison is thus a practical solution to this issue. However, it needs some regulations in order to ease its practice and legitimize its results. To do so, the French government hydrometrics teams produced a practical methodological guide for hydrometric inter-laboratory organisation in destination of hydrometers community in view of ensure the harmonization of inter-laboratory comparison practices for different materials (ADCP, current meter on wadind rod or gauging van, tracer dilution, surface speed) and flow range (flood, low water). Ensure the results formalization and banking. The realisation of this practice guide is grounded on the experience of the governmental teams & their partners (or fellows), following existing approaches (Doppler group especially). The guide is designated to validate compliance measures and identify outliers : Hardware, methodological, environmental, or human. Inter-laboratory comparison provides the means to verify the compliance of the instruments (devices + methods + operators) and provides methods to determine an experimental uncertainty of the tested measurement method which is valid only for the site and the measurement conditions but does not address the calibration or periodic monitoring of the few materials. After some conceptual definitions, the guide describes the different stages of an inter-comparison campaign: the campaing creation: targets, participants ( instruments type and number) and site preparation of test protocols and schedule; the campaign set-up (organization): invitation and pre-information of the participants, logistics, field preparation; the campaign conduct: participants reception and information, sequences of tests, results analysis and communication, balance sheet; post-campaign work: further analysis, dissemination and periodic verification of the instruments. This guide is associated with measurement instruments forms, reminding their limits and conditions for use, land forms, used to record all the necessary information during the inter-comparison campaign (site description and measurement conditions, equipment and its settings, and the set of measurements or intermediate calculations to the final results) as well as a calculation tool and banking measures and results.

  20. First Interlaboratory Comparison on Calibration of Temperature-Controlled Enclosures in Turkey

    NASA Astrophysics Data System (ADS)

    Uytun, A.; Kalemci, M.

    2017-11-01

    The number of accredited laboratories in the field of calibration of temperature-controlled enclosures has been increasing in Turkey. One of the main criteria demonstrating the competence of a calibration laboratory is successful participation in interlaboratory comparisons. Therefore, TUBITAK UME Temperature Laboratory organized the first interlaboratory comparison on "Calibration of Temperature-Controlled Enclosures" in Turkey as a pilot laboratory between January and November, 2013. Forty accredited laboratories which provide routine calibration services to the industry in this field participated in the comparison. The standards used during the comparison was a climatic chamber for the measurements at -40 {°}C, -20 {°}C, 40 {°}C and 100 {°}C and an oven for the measurements at 200 {°}C. The protocol of the comparison was prepared considering guide EURAMET cg-20 and BS EN/IEC standards 600068-3-5 and 600068-3-11. During the comparison measurements, each participant had the liberty to choose the most convenient calibration points in terms of their accreditation scope among the values mentioned above and carried out on-site measurements at UME. The details and the results of this comparison are given in the paper. Determination of the statistical consistency of the results with the uncertainties given by the participants can be assessed by the method of En value assessment for each laboratory. En values for all measurement results based on the results of pilot and participating laboratories were calculated.

  1. Interlaboratory and between-specimen comparisons of diagnostic tests for leptospirosis in sheep and cattle.

    PubMed

    Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie

    2014-11-01

    A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).

  2. LipidQC: Method Validation Tool for Visual Comparison to SRM 1950 Using NIST Interlaboratory Comparison Exercise Lipid Consensus Mean Estimate Values.

    PubMed

    Ulmer, Candice Z; Ragland, Jared M; Koelmel, Jeremy P; Heckert, Alan; Jones, Christina M; Garrett, Timothy J; Yost, Richard A; Bowden, John A

    2017-12-19

    As advances in analytical separation techniques, mass spectrometry instrumentation, and data processing platforms continue to spur growth in the lipidomics field, more structurally unique lipid species are detected and annotated. The lipidomics community is in need of benchmark reference values to assess the validity of various lipidomics workflows in providing accurate quantitative measurements across the diverse lipidome. LipidQC addresses the harmonization challenge in lipid quantitation by providing a semiautomated process, independent of analytical platform, for visual comparison of experimental results of National Institute of Standards and Technology Standard Reference Material (SRM) 1950, "Metabolites in Frozen Human Plasma", against benchmark consensus mean concentrations derived from the NIST Lipidomics Interlaboratory Comparison Exercise.

  3. Interlaboratory Analytical Comparison of Fatty Acid Concentrations in Serum or Plasma

    PubMed Central

    Schantz, Michele M.; Powers, Carissa D.; Schleicher, Rosemary L.; Betz, Joseph M.; Wise, Stephen A.

    2016-01-01

    The National Institute of Standards and Technology, in collaboration with the National Institutes of Health Office of Dietary Supplements and the Centers for Disease Control and Prevention, is conducting an accuracy-based program for improving the comparability of individual fatty acid measurements in serum and plasma. To date, two exercises of the Fatty Acid Quality Assurance Program (FAQAP) were conducted with 11 and 14 participants, respectively. The results from these two exercises indicate the need to improve the within-lab repeatability and between-lab reproducibility thus providing more confidence in the comparability of fatty acid measurements. PMID:27662814

  4. Transfer Standard Uncertainty Can Cause Inconclusive Inter-Laboratory Comparisons

    PubMed Central

    Wright, John; Toman, Blaza; Mickan, Bodo; Wübbeler, Gerd; Bodnar, Olha; Elster, Clemens

    2016-01-01

    Inter-laboratory comparisons use the best available transfer standards to check the participants’ uncertainty analyses, identify underestimated uncertainty claims or unknown measurement biases, and improve the global measurement system. For some measurands, instability of the transfer standard can lead to an inconclusive comparison result. If the transfer standard uncertainty is large relative to a participating laboratory’s uncertainty, the commonly used standardized degree of equivalence ≤ 1 criterion does not always correctly assess whether a participant is working within their uncertainty claims. We show comparison results that demonstrate this issue and propose several criteria for assessing a comparison result as passing, failing, or inconclusive. We investigate the behavior of the standardized degree of equivalence and alternative comparison measures for a range of values of the transfer standard uncertainty relative to the individual laboratory uncertainty values. The proposed alternative criteria successfully discerned between passing, failing, and inconclusive comparison results for the cases we examined. PMID:28090123

  5. A scoring metric for multivariate data for reproducibility analysis using chemometric methods

    PubMed Central

    Sheen, David A.; de Carvalho Rocha, Werickson Fortunato; Lippa, Katrice A.; Bearden, Daniel W.

    2017-01-01

    Process quality control and reproducibility in emerging measurement fields such as metabolomics is normally assured by interlaboratory comparison testing. As a part of this testing process, spectral features from a spectroscopic method such as nuclear magnetic resonance (NMR) spectroscopy are attributed to particular analytes within a mixture, and it is the metabolite concentrations that are returned for comparison between laboratories. However, data quality may also be assessed directly by using binned spectral data before the time-consuming identification and quantification. Use of the binned spectra has some advantages, including preserving information about trace constituents and enabling identification of process difficulties. In this paper, we demonstrate the use of binned NMR spectra to conduct a detailed interlaboratory comparison and composition analysis. Spectra of synthetic and biologically-obtained metabolite mixtures, taken from a previous interlaboratory study, are compared with cluster analysis using a variety of distance and entropy metrics. The individual measurements are then evaluated based on where they fall within their clusters, and a laboratory-level scoring metric is developed, which provides an assessment of each laboratory’s individual performance. PMID:28694553

  6. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  7. Inter-laboratory comparison study on measuring semi-volatile organic chemicals in standards and air samples.

    PubMed

    Su, Yushan; Hung, Hayley

    2010-11-01

    Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections <10% and with median differences of duplicate samples between 2.1 and 22%. Inter-laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences. 2010. Published by Elsevier Ltd. All rights reserved.

  8. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  9. Advanced emissions-speciation methodologies for the auto/oil air-quality improvement research program. 2. Aldehydes, ketones, and alcohols. SAE technical paper series

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swarin, S.J.; Loo, J.F.; Chladek, E.

    1992-01-01

    Analytical methods for determining individual aldehyde, ketone, and alcohol emissions from gasoline-, methanol-, and variable-fueled vehicles are described. These methods were used in the Auto/Oil Air Quality Improvement Research Program to provide emission data for comparison of individual reformulated fuels, individual vehicles, and for air modeling studies. The emission samples are collected in impingers which contain either 2,4-dinitrophenylhydrazine solution for the aldehydes and ketones or deionized water for the alcohols. Subsequent analyses by liquid chromatography for the aldehydes and ketones and gas chromatography for the alcohols utilized auto injectors and computerized data systems which permit high sample throughput with minimalmore » operator intervention. The quality control procedures developed and interlaboratory comparisons conducted as part of the program are also described. (Copyright (c) 1992 Society of Automotive Engineers, Inc.)« less

  10. First European interlaboratory comparison of tetracycline and age determination with red fox teeth following oral rabies vaccination programs.

    PubMed

    Robardet, Emmanuelle; Demerson, Jean-Michel; Andrieu, Sabrina; Cliquet, Florence

    2012-10-01

    The first European interlaboratory comparison of tetracycline and age determination with red fox (Vulpes vulpes) tooth samples was organized by the European Union Reference Laboratory for rabies. Performance and procedures implemented by member states were compared. These techniques are widely used to monitor bait uptake in European oral rabies vaccination campaigns. A panel of five red fox half-mandibles comprising one weak positive juvenile sample, two positive adult samples, one negative juvenile sample, and one negative adult sample were sent, along with a technical questionnaire, to 12 laboratories participating on a voluntary basis. The results of only three laboratories (25%) were 100% correct. False-negative results were more frequently seen in weak positive juvenile samples (58%) but were infrequent in positive adult samples (4%), probably due to differences in the ease of reading the two groups of teeth. Four laboratories (44%) had correct results for age determination on all samples. Ages were incorrectly identified in both adult and juvenile samples, with 11 and 17% of discordant results, respectively. Analysis of the technical questionnaires in parallel with test results suggested that all laboratories cutting mandible sections between the canine and first premolar obtained false results. All the laboratories using longitudinal rather than transverse sections and those not using a mounting medium also produced false results. Section thickness appeared to affect the results; no mistakes were found in laboratories using sections <150 μm thick. Factors having a potential impact on the success of laboratories were discussed, and recommendations proposed. Such interlaboratory trials underline the importance of using standardized procedures for biomarker detection in oral rabies vaccination campaigns. Several changes can be made to improve analysis quality and increase the comparability of bait uptake frequencies among member states.

  11. Interlaboratory comparability, bias, and precision for four laboratories measuring analytes in wet deposition, October 1983-December 1984

    USGS Publications Warehouse

    Brooks, Myron H.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1987-01-01

    Four laboratories involved in the routine analysis of wet-deposition samples participated in an interlaboratory comparison program managed by the U.S. Geological Survey. The four participants were: Illinois State Water Survey central analytical laboratory in Champaign, Illinois; U.S. Geological Survey national water-quality laboratories in Atlanta, Georgia, and Denver, Colorado; and Inland Waters Directorate national water-quality laboratory in Burlington, Ontario, Canada. Analyses of interlaboratory samples performed by the four laboratories from October 1983 through December 1984 were compared.Participating laboratories analyzed three types of interlaboratory samples--natural wet deposition, simulated wet deposition, and deionized water--for pH and specific conductance, and for dissolved calcium, magnesium, sodium, sodium, potassium, chloride, sulfate, nitrate, ammonium, and orthophosphate. Natural wet-deposition samples were aliquots of actual wet-deposition samples. Analyses of these samples by the four laboratories were compared using analysis of variance. Test results indicated that pH, calcium, nitrate, and ammonium results were not directly comparable among the four laboratories. Statistically significant differences between laboratory results probably only were meaningful for analyses of dissolved calcium. Simulated wet-deposition samples with known analyte concentrations were used to test each laboratory for analyte bias. Laboratory analyses of calcium, magnesium, sodium, potassium, chloride, sulfate, and nitrate were not significantly different from the known concentrations of these analytes when tested using analysis of variance. Deionized-water samples were used to test each laboratory for reporting of false positive values. The Illinois State Water Survey Laboratory reported the smallest percentage of false positive values for most analytes. Analyte precision was estimated for each laboratory from results of replicate measurements. In general, the Illinois State Water Survey laboratory achieved the greatest precision, whereas the U.S. Geological Survey laboratories achieved the least precision.

  12. Ultra-trace analysis of 41Ca in urine by accelerator mass spectrometry: an inter-laboratory comparison

    PubMed Central

    Jackson, George S.; Hillegonds, Darren J.; Muzikar, Paul; Goehring, Brent

    2013-01-01

    A 41Ca interlaboratory comparison between Lawrence Livermore National Laboratory (LLNL) and the Purdue Rare Isotope Laboratory (PRIME Lab) has been completed. Analysis of the ratios assayed by accelerator mass spectrometry (AMS) shows that there is no statistically significant difference in the ratios. Further, Bayesian analysis shows that the uncertainties reported by both facilities are correct with the possibility of a slight under-estimation by one laboratory. Finally, the chemistry procedures used by the two facilities to produce CaF2 for the cesium sputter ion source are robust and don't yield any significant differences in the final result. PMID:24179312

  13. Results of the first provisional technical secretariat interlaboratory comparison test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuff, J.R.; Hoffland, L.

    1995-06-01

    The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.

  14. Evaluation of cross-connected waveguides as transfer standards of transmission at high millimetre-wave frequencies

    NASA Astrophysics Data System (ADS)

    Ridler, Nick; Clarke, Roland; Huang, Hui; Zinal, Sherko

    2016-08-01

    At the present time, transfer and verification standards of transmission coefficient (or, equivalently, transmission loss) are not readily available at high millimetre-wave frequencies (i.e. at frequencies ranging typically from 100 GHz to 300 GHz). In recent years, cross-connected waveguide devices have been proposed to provide calculable standards of transmission loss at these frequencies. This paper investigates the viability of these cross-connected waveguides as transfer standards of transmission for inter-laboratory measurement comparison exercises. This relates to their potential use in activities such as international key comparison exercises and measurement audit programmes. A trial inter-laboratory comparison involving four laboratories using two cross-connected waveguides in the WR-05 waveguide size (covering frequencies from 140 GHz to 220 GHz) is described and includes an analysis of the measurement results obtained during the comparison exercise.

  15. Bias from two analytical laboratories involved in a long-term air monitoring program measuring organic pollutants in the Arctic: a quality assurance/quality control assessment.

    PubMed

    Su, Yushan; Hung, Hayley; Stern, Gary; Sverko, Ed; Lao, Randy; Barresi, Enzo; Rosenberg, Bruno; Fellin, Phil; Li, Henrik; Xiao, Hang

    2011-11-01

    Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.

  16. Interlaboratory comparison of fluorocarbons-11, -12, methylchloroform and nitrous oxide measurements

    NASA Technical Reports Server (NTRS)

    Rasmussen, R. A.; Khalil, M. A. K.

    1981-01-01

    Measurements conducted by 19 participating laboratories were considered in the reported interlaboratory comparison study. The results show that there is considerable disagreement among laboratories regarding the absolute concentrations of all four trace gases (CCl3F, CCl2F2, H3CCl3, N2O). The magnitude of this disagreement is discussed. Laboratories in Group II showed considerable disagreement among themselves. Their results were scattered within large intervals of concentration. Laboratories in Group I (using common standards) were in excellent (+ or - 5%) agreement among themselves. A systematic disagreement was noted between Groups I and II laboratories. Generally, the mean values of concentrations determined from the measurements of Group II laboratories were lower than the mean values reported by Group I laboratories.

  17. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian procedure; and the Linear Pool. These three procedures have been implemented and made widely accessible in a Web-based application (NIST Consensus Builder). We illustrate principles, statistical models, and data reduction procedures in four examples: (i) the measurement of the Newtonian constant of gravitation; (ii) the measurement of the half-lives of radioactive isotopes of caesium and strontium; (iii) the comparison of two alternative treatments for carotid artery stenosis; and (iv) a key comparison where the measurand was the calibration factor of a radio-frequency power sensor.

  18. Final report of EURAMET 1197: Supplementary bilateral comparison of hydraulic gauge pressure standards up to 50 MPa

    NASA Astrophysics Data System (ADS)

    Durgut, Yasin; Petrovski, Nenad; Kacarski, Vanco

    2012-01-01

    Interlaboratory comparisons are important for the laboratories to assess their own measurement capability. It is equally important for the accreditation bodies and assessors during the audit process of a laboratory to judge whether the laboratory is doing well. As per accreditation rules, it is mandatory for the testing and calibration laboratories to participate in such comparisons from time to time. In this report, results of the bilateral interlaboratory comparison in pressure area in hydraulic media up to 50 MPa gauge between UME (Turkey) and BOM (The FYR of Macedonia) are presented. The artefact used for the comparison was a digital pressure calibrator and its drift was taken into account in the calculation. Results show that all En values lie in acceptable limits. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    PubMed Central

    Lu, Z. Q. J.; Lowhorn, N. D.; Wong-Ng, W.; Zhang, W.; Thomas, E. L.; Otani, M.; Green, M. L.; Tran, T. N.; Caylor, C.; Dilley, N. R.; Downey, A.; Edwards, B.; Elsner, N.; Ghamaty, S.; Hogan, T.; Jie, Q.; Li, Q.; Martin, J.; Nolas, G.; Obara, H.; Sharp, J.; Venkatasubramanian, R.; Willigan, R.; Yang, J.; Tritt, T.

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations. PMID:27504212

  20. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--part 2: forensic inter-laboratory trial: bulk carbon and nitrogen stable isotopes in a range of chemical compounds (Australia and New Zealand).

    PubMed

    Benson, Sarah J; Lennard, Christopher J; Maynard, Philip; Hill, David M; Andrew, Anita S; Neal, Ken; Stuart-Williams, Hilary; Hope, Janet; Walker, G Stewart; Roux, Claude

    2010-01-01

    Comparability of data over time and between laboratories is a key issue for consideration in the development of global databases, and more broadly for quality assurance in general. One mechanism that can be utilized for evaluating traceability is an inter-laboratory trial. This paper addresses an inter-laboratory trial conducted across a number of Australian and New Zealand isotope ratio mass spectrometry (IRMS) laboratories. The main objective of this trial was to determine whether IRMS laboratories in these countries would record comparable values for the distributed samples. Four carbon containing and four nitrogen containing compounds were distributed to seven laboratories in Australia and one in New Zealand. The laboratories were requested to analyze the samples using their standard procedures. The data from each laboratory was evaluated collectively using International Standard ISO 13528 (Statistical methods for use in proficiency testing by inter-laboratory comparisons). "Warning signals" were raised against one participant in this trial. "Action signals" requiring corrective action were raised against four participants. These participants reviewed the data and possible sources for the discrepancies. This inter-laboratory trial was successful in providing an initial snapshot of the potential for traceability between the participating laboratories. The statistical methods described in this article could be used as a model for others needing to evaluate stable isotope results derived from multiple laboratories, e.g., inter-laboratory trials/proficiency testing. Ongoing trials will be conducted to improve traceability across the Australian and New Zealand IRMS community.

  1. Inter-laboratory comparisons of short-lived gamma-emitting radionuclides in nuclear reactor water.

    PubMed

    Klemola, S K

    2008-01-01

    Inter-laboratory comparisons of gamma-emitting nuclides in nuclear power plant coolant water have been carried out in Finland since 1994. The reactor water samples are taken and prepared by one of the two nuclear power plants and delivered to the participants. Since all the participants get their sample within just a few hours it has been possible to analyse and compare results of nuclides with half-lives shorter than 1h. The total number of short-lived nuclides is 26. All the main nuclides are regularly identified and the activities have been obtained with reasonable accuracy throughout the years. The overall deviation of the results has decreased in 13 years. The effects of true coincidence summing and discrepancies in nuclear data have been identified as potential sources of remaining discrepancies. All the participants have found this type of comparison very useful.

  2. Statistical analysis of an inter-laboratory comparison of small-scale safety and thermal testing of RDX

    DOE PAGES

    Brown, Geoffrey W.; Sandstrom, Mary M.; Preston, Daniel N.; ...

    2014-11-17

    In this study, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency test for small-scale safety and thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results from this test for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Class 5 Type II standard. The material was tested as a well-characterized standard several times during the proficiency test to assess differences among participants and the range of results that may arise for well-behaved explosive materials.

  3. Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevcik, R. S.; Hyman, D. A.; Basumallich, L.

    2013-01-01

    A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymaticmore » saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.« less

  4. Harmonization of urine albumin/creatinine ratio (ACR) results: a study based on an external quality assessment program in Polish laboratories.

    PubMed

    Ćwiklińska, Agnieszka; Dąbrowska, Hanna; Kowalski, Robert; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Fijałkowska, Aleksandra; Bednarczuk, Gabriela; Jankowski, Maciej

    2018-05-11

    The ratio of albumin to creatinine (ACR) is an important parameter used for detection of albuminuria in patients with early kidney damage. The aim of the study was to evaluate the harmonization of ACR results among Polish participants in an international external quality assessment (EQA) program, and to evaluate the impact of albumin and creatinine analytical performance on the harmonization of ACR results. We analyzed 182 results of albumin, 202 of creatinine, and 180 of ACR obtained from Polish laboratories in an EQA program organized by Labquality. The dispersion of the results in surveys and percentage differences between the results and target values were calculated. Moreover, differences between method groups were assessed. The inter-laboratory coefficient of variation (CV) for ACR was 36%. Only 74% of results of Polish laboratories were within the target limits; for 11% of the results, an incorrect albuminuria category would have been reported. The inter-laboratory CV for albumin was 20%, 2.6-fold higher than for creatinine. Significant differences between method groups for albumin determination have been observed, even when the same measurement technique was used. The greatest difference between two groups was 23%, 2.5-fold greater in comparison to creatinine. There is an insufficient harmonization of ACR values among Polish laboratories, caused mainly by urine albumin analytical performance. Given the important role of ACR in the classification, monitoring and treatment of kidney damage, the harmonization of albumin measurements is crucial and urgently needed.

  5. Interlaboratory Comparison of Magnetic Thin Film Measurements.

    PubMed

    da Silva, F C S; Wang, C M; Pappas, D P

    2003-01-01

    A potential low magnetic moment standard reference material (SRM) was studied in an interlaboratory comparison. The mean and the standard deviation of the saturation moment m s, the remanent moment m r, and the intrinsic coercivity H c of nine samples were extracted from hysteresis-loop measurements. Samples were measured by thirteen laboratories using inductive-field loopers, vibrating-sample magnetometers, alternating-gradient force magnetometers, and superconducting quantum-interference-device magnetometers. NiFe films on Si substrates had saturation moment measurements reproduced within 5 % variation among the laboratories. The results show that a good candidate for an SRM must have a highly square hysteresis loop (m r/m s > 90 %), H c ≈ 400 A·m(-1) (5 Oe), and m s ≈ 2 × 10(-7) A·m(2) (2 × 10(-4) emu).

  6. Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.

    PubMed

    Plappert-Helbig, Ulla; Guérard, Melanie

    2015-12-01

    To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.

  7. Underground Test Area Fiscal Year 2014 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krenzien, Susan

    2015-01-01

    This report is required by the Underground Test Area (UGTA) Quality Assurance Plan (QAP) and identifies the UGTA quality assurance (QA) activities from October 1, 2013, through September 30, 2014 (fiscal year [FY] 2014). All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); National Security Technologies, LLC (NSTec); Navarro-Intera, LLC (N-I); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2014. The activities included conducting oversight assessments for QAP compliance, identifying findings and completing corrective actions, evaluating laboratory performance,more » and publishing documents. UGTA Activity participants conducted 25 assessments on topics including safe operations, QAP compliance, activity planning, and sampling. These assessments are summarized in Section 2.0. Corrective actions tracked in FY 2014 are presented in Appendix A. Laboratory performance was evaluated based on three approaches: (1) established performance evaluation programs (PEPs), (2) interlaboratory comparisons, or (3) data review. The results of the laboratory performance evaluations, and interlaboratory comparison results are summarized in Section 4.0. The UGTA Activity published three public documents and a variety of other publications in FY 2014. The titles, dates, and main authors are identified in Section 5.0. The Contract Managers, Corrective Action Unit (CAU) Leads, Preemptive Review (PER) Committee members, and Topical Committee members are listed by name and organization in Section 6.0. Other activities that affected UGTA quality are discussed in Section 7.0. Section 8.0 provides the FY 2014 UGTA QA program conclusions, and Section 9.0 lists the references not identified in Section 5.0.« less

  8. Properties and chemical constituents in ground water from the middle Claiborne Aquifer, Gulf Coast regional aquifer systems, south-central United States

    USGS Publications Warehouse

    Pettijohn, Robert A.; Busby, John F.; Cervantes, Michael A.

    1993-01-01

    The U.S. Geological Survey used four programs in 1990 to provide external data quality assurance for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Results of the intersite- comparison program indicate that 80 and 74 percent of the site operators met the NADP/NTN goals for pH determination and 98 and 95 percent of the site operators met the NADP/NTN goals for specific- conductance determination during the two studies in 1990. The effects of routine sample handling, processing, and shipping determined in the blind-audit program indicated significant positive bias for calcium, magnesium, sodium, potassium, chloride, nitrate, and sulfate. Significant negative bias was determined for hydrogen ion and specific conductance. A Kruskal-Wallis test indicated that there were no significant (a=0.01) differences in analytical results from the three laboratories participating in the interlaboratory-comparison program. Results from the collocated-sampler study indicate the median relative error for potassium and ammonium concentration and deposition exceeded 15 percent at most sites while the median relative error for sulfate and nitrate at all sites was less than 6 percent for concentration and was less than 15 percent for deposition.

  9. Inter-laboratory comparison measurements of radiochemical laboratories in Slovakia.

    PubMed

    Meresová, J; Belanová, A; Vrsková, M

    2010-01-01

    The first inter-laboratory comparison organized by the radiochemistry laboratory of Water Research Institute (WRI) in Bratislava was carried out in 1993 and since then is it realized on an annual basis and about 10 radiochemical laboratories from all over Slovakia are participating. The gross alpha and gross beta activities, and the activity concentrations of (222)Rn, tritium, and (226)Ra, and U(nat) concentration in synthetic water samples are compared. The distributed samples are covering the concentration range prevailing in potable and surface waters and are prepared by dilution of certified reference materials. Over the course of the years 1993-2008, we observed the improvement in the quality of results for most of the laboratories. However, the success rate of the gross alpha determination activity is not improving as much as the other parameters. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. GaMin’11 – an international inter-laboratory comparison for geochemical CO₂ - saline fluid - mineral interaction experiments

    DOE PAGES

    Ostertag-Henning, C.; Risse, A.; Thomas, B.; ...

    2014-12-31

    Due to the strong interest in geochemical CO₂-fluid-rock interaction in the context of geological storage of CO₂ a growing number of research groups have used a variety of different experimental ways to identify important geochemical dissolution or precipitation reactions and – if possible – quantify the rates and extent of mineral or rock alteration. In this inter-laboratory comparison the gas-fluid-mineral reactions of three samples of rock-forming minerals have been investigated by 11 experimental labs. The reported results point to robust identification of the major processes in the experiments by most groups. The dissolution rates derived from the changes in compositionmore » of the aqueous phase are consistent overall, but the variation could be reduced by using similar corrections for changing parameters in the reaction cells over time. The comparison of experimental setups and procedures as well as of data corrections identified potential improvements for future gas-fluid-rock studies.« less

  11. Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR.

    PubMed

    Dobnik, David; Demšar, Tina; Huber, Ingrid; Gerdes, Lars; Broeders, Sylvia; Roosens, Nancy; Debode, Frederic; Berben, Gilbert; Žel, Jana

    2018-01-01

    Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection. Graphical abstract The output of three different PCR-based platforms was assessed in an inter-laboratory comparison.

  12. Inter-laboratory comparison of X-ray fluorescence analyses of eruptive products of El Chichón Volcano, Chiapas, Mexico

    USGS Publications Warehouse

    Tilling, Robert I.; Bornhorst, Theodore J.; Taggart, Joseph E.; Rose, William I.; McGee, James J.

    1987-01-01

    An inter-laboratory comparison has been made of X-ray fluorescence analyses of 10 samples of lava and pumices from El Chichón Volcano, Chiapas, Mexico. Some determinations of major-element constituents agree within analytical uncertainty, whereas others exchibit significant bias. Analyses carried out at the Michigan Technological University (MTU) laboratory are systematically lower in MgO (26–48%), Fetotal(5–18%), CaO (4–15%) and higher in K2O (0–15%) than analyses made at the U.S. Geological Survey (USGS) Denver laboratory. These differences are ascribed in part to a complex combination of calibration assumptionsand mineralogical and particle-size effects inherent in the use of pressed rock-powder pellets in the analytical procedure of the MTU laboratory. Other, but as yet unknown, differences in sample preparation and/or analytical technique may also be important; effects related to natural sample inhomogeneityare believed to be insignificant. The inter-laboratory differences in the analytical data complicated accurate assessment of whether El Chichón magmas have changed composition during the past 300 000 a. Knowledge of such change is needed for understanding petrogenetic history and for such related studies as evaluation of volcanic hazards.

  13. Interlaboratory tests for low-level radioactivity measurements in France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Despres, M.

    In the framework of French national metrological coordination, the Laboratoire de Metrologie des Rayonnements Ionisants (LMRI) organizes every year an interlaboratory test program. The participation in these programs is on a voluntary basis and the results are presented in a nameless way. These tests concern radioactivity, neutron and dosimetry measurements. In this paper, a review of interlaboratory tests for low-level radioactivity measurements proposed by LMRI is given from 1975 to 1986. Every year, three types of tests are proposed: activity tests, multigamma tests, radioanalysis tests. For the last ten years, the number of results has been respectively 90 for activitymore » tests, 570 for multigamma tests and 400 for radioanalysis tests. The user's interest has increased, while the quality of results has improved. The deviations from LMRI's reference values are less than 3% for a restricted number of laboratories, and range between 3 and 10% for the majority of the others. The most urgent tests are for mixtures of {sup 90}Sr and activation and fission products in various matrices such as milk, grass, cereals, and sediments. 16 refs., 3 figs., 3 tabs.« less

  14. Interlaboratory comparison of extraction efficiency of pesticides from surface and laboratory water using solid-phase extraction disks.

    PubMed

    Senseman, Scott A; Mueller, Thomas C; Riley, Melissa B; Wauchope, R Don; Clegg, Chris; Young, Roddy W; Southwick, Lloyd M; Moye, H Anson; Dumas, Jose A; Mersie, Wondi; Mattice, John D; Leidy, Ross B

    2003-06-18

    A continuation of an earlier interlaboratory comparison was conducted (1) to assess solid-phase extraction (SPE) using Empore disks to extract atrazine, bromacil, metolachlor, and chlorpyrifos from various water sources accompanied by different sample shipping and quantitative techniques and (2) to compare quantitative results of individual laboratories with results of one common laboratory. Three replicates of a composite surface water (SW) sample were fortified with the analytes along with three replicates of deionized water (DW). A nonfortified DW sample and a nonfortified SW sample were also extracted. All samples were extracted using Empore C(18) disks. After extraction, part of the samples were eluted and analyzed in-house. Duplicate samples were evaporated in a 2-mL vial, shipped dry to a central laboratory (SDC), redissolved, and analyzed. Overall, samples analyzed in-house had higher recoveries than SDC samples. Laboratory x analysis type and laboratory x water source interactions were significant for all four compounds. Seven laboratories participated in this interlaboratory comparison program. No differences in atrazine recoveries were observed from in-house samples analyzed by laboratories A, B, D, and G compared with the recovery of SDC samples. In-house atrazine recoveries from laboratories C and F were higher when compared with recovery from SDC samples. However, laboratory E had lower recoveries from in-house samples compared with SDC samples. For each laboratory, lower recoveries were observed for chlorpyrifos from the SDC samples compared with samples analyzed in-house. Bromacil recovery was <65% at two of the seven laboratories in the study. Bromacil recoveries for the remaining laboratories were >75%. Three laboratories showed no differences in metolachlor recovery; two laboratories had higher recoveries for samples analyzed in-house, and two other laboratories showed higher metolachlor recovery for SDC samples. Laboratory G had a higher recovery in SW for all four compounds compared with DW. Other laboratories that had significant differences in pesticide recovery between the two water sources showed higher recovery in DW than in the SW regardless of the compound. In comparison to earlier work, recovery of these compounds using SPE disks as a temporary storage matrix may be more effective than shipping dried samples in a vial. Problems with analytes such as chlorpyrifos are unavoidable, and it should not be assumed that an extraction procedure using SPE disks will be adequate for all compounds and transferrable across all chromatographic conditions.

  15. Interlaboratory Comparison Test as an Evaluation of Applicability of an Alternative Edible Oil Analysis by 1H NMR Spectroscopy.

    PubMed

    Zailer, Elina; Holzgrabe, Ulrike; Diehl, Bernd W K

    2017-11-01

    A proton (1H) NMR spectroscopic method was established for the quality assessment of vegetable oils. To date, several research studies have been published demonstrating the high potential of the NMR technique in lipid analysis. An interlaboratory comparison was organized with the following main objectives: (1) to evaluate an alternative analysis of edible oils by using 1H NMR spectroscopy; and (2) to determine the robustness and reproducibility of the method. Five different edible oil samples were analyzed by evaluating 15 signals (free fatty acids, peroxides, aldehydes, double bonds, and linoleic and linolenic acids) in each spectrum. A total of 21 NMR data sets were obtained from 17 international participant laboratories. The performance of each laboratory was assessed by their z-scores. The test was successfully passed by 90.5% of the participants. Results showed that NMR spectroscopy is a robust alternative method for edible oil analysis.

  16. (60)Co in cast steel matrix: A European interlaboratory comparison for the characterisation of new activity standards for calibration of gamma-ray spectrometers in metallurgy.

    PubMed

    Tzika, Faidra; Burda, Oleksiy; Hult, Mikael; Arnold, Dirk; Marroyo, Belén Caro; Dryák, Pavel; Fazio, Aldo; Ferreux, Laurent; García-Toraño, Eduardo; Javornik, Andrej; Klemola, Seppo; Luca, Aurelian; Moser, Hannah; Nečemer, Marijan; Peyrés, Virginia; Reis, Mario; Silva, Lidia; Šolc, Jaroslav; Svec, Anton; Tyminski, Zbigniew; Vodenik, Branko; Wätjen, Uwe

    2016-08-01

    Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Inter-laboratory comparison of multi-locus variable-number tandem repeat analysis (MLVA) for verocytotoxin-producing Escherichia coli O157 to facilitate data sharing.

    PubMed

    Holmes, A; Perry, N; Willshaw, G; Hanson, M; Allison, L

    2015-01-01

    Multi-locus variable number tandem repeat analysis (MLVA) is used in clinical and reference laboratories for subtyping verocytotoxin-producing Escherichia coli O157 (VTEC O157). However, as yet there is no common allelic or profile nomenclature to enable laboratories to easily compare data. In this study, we carried out an inter-laboratory comparison of an eight-loci MLVA scheme using a set of 67 isolates of VTEC O157. We found all but two isolates were identical in profile in the two laboratories, and repeat units were homogeneous in size but some were incomplete. A subset of the isolates (n = 17) were sequenced to determine the actual copy number of representative alleles, thereby enabling alleles to be named according to international consensus guidelines. This work has enabled us to realize the potential of MLVA as a portable, highly discriminatory and convenient subtyping method.

  18. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    PubMed Central

    2018-01-01

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (

  19. External quality-assurance results for the national atmospheric deposition program/national trends network, 2000-2001

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Latysh, Natalie E.; Gordon, John D.

    2004-01-01

    Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) from 2000 through 2001 (study period): the intersite-comparison program, the blind-audit program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program is designed to measure specific components of the total error inherent in NADP/NTN wet-deposition measurements. The intersite-comparison program assesses the variability and bias of pH and specific-conductance determinations made by NADP/NTN site operators with respect to accuracy goals. The accuracy goals are statistically based using the median of all of the measurements obtained for each of four intersite-comparison studies. The percentage of site operators responding on time that met the pH accuracy goals ranged from 84.2 to 90.5 percent. In these same four intersite-comparison studies, 88.9 to 99.0 percent of the site operators met the accuracy goals for specific conductance. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the chemistry of weekly precipitation samples. The blind-audit data for the study period indicate that sample handling introduced a small amount of sulfate contamination and slight changes to hydrogen-ion content of the precipitation samples. The magnitudes of the paired differences are not environmentally significant to NADP/NTN data users. The field-audit program (also known as the 'field-blank program') was designed to measure the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. The results indicate potential low-level contamination of NADP/NTN samples with calcium, ammonium, chloride, and nitrate. Less sodium contamination was detected by the field-audit data than in previous years. Statistical analysis of the paired differences shows that contaminant ions are entrained into the solutions from the field-exposed buckets, but the positive bias that results from the minor amount of contamination appears to affect the analytical results by less than 6 percent. An interlaboratory-comparison program is used to estimate the analytical variability and bias of participating laboratories, especially the NADP Central Analytical Laboratory (CAL). Statistical comparison of the analytical results of participating laboratories implies that analytical data from the various monitoring networks can be compared. Bias was identified in the CAL data for ammonium, chloride, nitrate, sulfate, hydrogen-ion, and specific-conductance measurements, but the absolute value of the bias was less than analytical minimum reporting limits for all constituents except ammonium and sulfate. Control charts show brief time periods when the CAL's analytical precision for sodium, ammonium, and chloride was not within the control limits. Data for the analysis of ultrapure deionized-water samples indicated that the laboratories are maintaining good control of laboratory contamination. Estimated analytical precision among the laboratories indicates that the magnitudes of chemical-analysis errors are not environmentally significant to NADP data users. Overall precision of the precipitation-monitoring system used by the NADP/NTN was estimated by evaluation of samples from collocated monitoring sites at CA99, CO08, and NH02. Precision defined by the median of the absolute percent difference (MAE) was estimated to be approximately 10 percent or less for calcium, magnesium, sodium, chloride, nitrate, sulfate, specific conductance, and sample volume. The MAE values for ammonium and hydrogen-ion concentrations were estimated to be less than 10 percent for CA99 and NH02 but nearly 20 percent for ammonium concentration and about 17 percent for hydrogen-ion concentration for CO08. As in past years, the variability in the collocated-site data for sam

  20. An interlaboratory comparison programme on radio frequency electromagnetic field measurements: the second round of the scheme.

    PubMed

    Nicolopoulou, E P; Ztoupis, I N; Karabetsos, E; Gonos, I F; Stathopulos, I A

    2015-04-01

    The second round of an interlaboratory comparison scheme on radio frequency electromagnetic field measurements has been conducted in order to evaluate the overall performance of laboratories that perform measurements in the vicinity of mobile phone base stations and broadcast antenna facilities. The participants recorded the electric field strength produced by two high frequency signal generators inside an anechoic chamber in three measurement scenarios with the antennas transmitting each time different signals at the FM, VHF, UHF and GSM frequency bands. In each measurement scenario, the participants also used their measurements in order to calculate the relative exposure ratios. The results were evaluated in each test level calculating performance statistics (z-scores and En numbers). Subsequently, possible sources of errors for each participating laboratory were discussed, and the overall evaluation of their performances was determined by using an aggregated performance statistic. A comparison between the two rounds proves the necessity of the scheme. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Comparison of bulk sediment and sediment elutriate toxicity testing methods

    EPA Science Inventory

    Elutriate bioassays are among numerous methods that exist for assessing the potential toxicity of sediments in aquatic systems. In this study, interlaboratory results were compared from 96-hour Ceriodaphnia dubia and Pimephales promelas static-renewal acute toxicity tests conduct...

  2. Performance Characteristics of Urinary Tract Cytology: Observations From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology.

    PubMed

    Barkan, Güliz A; Laucirica, Rodolfo; Auger, Manon; Khalbuss, Walid; Padmanabhan, Vijyalakshmi; Souers, Rhona; Moriarty, Ann T

    2015-08-01

    Urine cytology is used in the evaluation of hematuria or to follow patients with known urothelial neoplasia. To investigate the performance characteristics of urinary cytology challenges in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology. Participant responses from 2000 to 2010 were evaluated for the reference diagnoses of high-grade urothelial carcinoma (HGUC), squamous cell carcinoma, adenocarcinoma, and benign diagnoses (including polyomavirus infection and ileal loop urine). Responses were compared for differences in sample preparation (conventional, liquid based, and cytospin) and participant type (laboratory, pathologist, cytotechnologist). There were 96 093 responses (46 637 pathologists [48.5%], 29 976 cytotechnologists [31.2%], and 19 480 laboratories [20.3%]); 69 814 of 74 821 responses (93.3%) for the general category positive for malignancy and 18 698 of 21 272 responses (87.9%) for positive for malignancy were concordant. Of the malignant reference diagnoses, 83.3% (59 985 of 71 581), 43.9% (732 of 1667), and 49.1% (370 of 756) were correctly identified as HGUC, adenocarcinoma, and squamous cell carcinoma, respectively. However, 802 of 1669 adenocarcinoma challenges (48.1%) and 275 of 755 squamous cell carcinoma challenges (36.4%) were misdiagnosed as HGUC. For the benign cases, the most common diagnostic pitfall was overinterpretation of ileal loop urines (330 of 5291; 6.2%) and Polyomavirus challenges (220 of 3535; 6.2%) as HGUC. For the general diagnosis of positive for malignancy, cytotechnologists performed slightly better that pathologists (94.5% [23 553 of 24 924] versus 92.3% [36 210 of 39 230]), whereas the reverse occurred for the negative category (85.6% [6423 of 7503] versus 88.8% [10 427 of 11 742]). Although the participants performed well in accurately classifying cases as benign and malignant, there were difficulties with the correct identification of adenocarcinoma and squamous cell carcinoma cases and with overinterpretation of ileal loop and Polyomavirus challenges as HGUC.

  3. Interlaboratory Comparison of Quantitative PCR Test Results for Dehalococcoides

    EPA Science Inventory

    Quantitative PCR (qPCR) techniques have been widely used to measure Dehalococcoides (Dhc) DNA in the groundwater at field sites for several years. Interpretation of these data may be complicated when different laboratories using alternate methods conduct the analysis. An...

  4. Global Inter-Laboratory Fecal Source Identification Methods Comparison Study

    EPA Science Inventory

    Source tracking is key to identifying sources of fecal contamination for remediation as well as risk assessment. Previous intra- and inter-lab studies have investigated the performance of human and cow-associated source tracking markers, as well as library-dependent fecal source ...

  5. Report on the CCT Supplementary Comparison S1 of Infrared Spectral Normal Emittance/Emissivity

    PubMed Central

    Hanssen, Leonard; Wilthan, B.; Monte, Christian; Hollandt, Jörg; Hameury, Jacques; Filtz, Jean-Remy; Girard, Ferruccio; Battuello, Mauro; Ishii, Juntaro

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes’ infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. PMID:28239193

  6. The CD117 immunohistochemistry tissue microarray survey for quality assurance and interlaboratory comparison: a College of American Pathologists Cell Markers Committee Study.

    PubMed

    Dorfman, David M; Bui, Marilyn M; Tubbs, Raymond R; Hsi, Eric D; Fitzgibbons, Patrick L; Linden, Michael D; Rickert, Robert R; Roche, Patrick C

    2006-06-01

    We have developed tissue microarray-based surveys to allow laboratories to compare their performance in staining predictive immunohistochemical markers, including proto-oncogene CD117 (c-kit), which is characteristically expressed in gastrointestinal stromal tumors (GISTs). GISTs exhibit activating mutations in the c-kit proto-oncogene, which render them amenable to treatment with imatinib mesylate. Consequently, correct identification of c-Kit expression is important for the diagnosis and treatment of GISTs. To analyze CD117 immunohistochemical staining performance by a large number of clinical laboratories. A mechanical device was used to construct tissue microarrays consisting of 3 x 1-mm cores of 10 tumor samples, which can be used to generate hundreds of tissue sections from the arrayed cases, suitable for large-scale interlaboratory comparison of immunohistochemical staining. An initial survey of 63 laboratories and a second survey of 90 laboratories, performed in 2004 and 2005, exhibited >81% concordance for 7 of 10 cores, including all 4 GIST cases, which were immunoreactive for CD117 with >95% staining concordance. Three of the cores achieved less than 81% concordance of results, possibly due to the presence of foci of necrosis in one core and CD117-positive mast cells in 2 cores of CD117-negative neoplasms. There was good performance among a large number of laboratories performing CD117 immunohistochemical staining, with consistently higher concordance of results for CD117-positive GIST cases than for nonimmunoreactive cases. Tissue microarrays for CD117 and other predictive markers should be useful for interlaboratory comparisons, quality assurance, and education of participants regarding staining nuances such as the expression of CKIT by nonneoplastic mast cells.

  7. Particle size distributions by transmission electron microscopy: an interlaboratory comparison case study

    PubMed Central

    Rice, Stephen B; Chan, Christopher; Brown, Scott C; Eschbach, Peter; Han, Li; Ensor, David S; Stefaniak, Aleksandr B; Bonevich, John; Vladár, András E; Hight Walker, Angela R; Zheng, Jiwen; Starnes, Catherine; Stromberg, Arnold; Ye, Jia; Grulke, Eric A

    2015-01-01

    This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin–Rammler–Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition. PMID:26361398

  8. Inter-laboratory comparison of xenobiotic clearance rates determined using cryopreserved trout hepatocytes for improving bioaccumulation predictions

    EPA Science Inventory

    Hepatic biotransformation is an important determinant of chemical bioaccumulation in fish. Consequently, bioaccumulation models can be improved using estimates of chemical biotransformation rates. Cryopreserved trout hepatocytes have been used to measure the clearance rates of so...

  9. Inter-laboratory comparison of clearance rates of xenobiotics by cryopreserved trout hepatocytes for the prediction of bioaccumulation potential

    EPA Science Inventory

    Hepatic biotransformation is an important determinant of chemical bioaccumulation in fish. Consequently, improvements to bioaccumulation models can be made using estimates of chemical biotransformation rates. Cryopreserved trout hepatocytes have previously been used to measure ...

  10. INTERLABORATORY METHODS COMPARISON FOR THE TOTAL ORGANIC CARBON ANALYSIS OF AQUIFER MATERIALS

    EPA Science Inventory

    The total organic carbon (TOC) content of aquifer materials has been found to have significant effects on the movement of pollutants in the subsurface environment. Accurate quantification of TOC is therefore of great im- portance to research in groundwater contamination. However,...

  11. Interlaboratory comparison for the determination of the soluble fraction of metals in welding fume samples.

    PubMed

    Berlinger, Balazs; Harper, Martin

    2018-02-01

    There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.

  12. Key comparison CCPR-K1.a as an interlaboratory comparison of correlated color temperature

    NASA Astrophysics Data System (ADS)

    Kärhä, P.; Vaskuri, A.; Pulli, T.; Ikonen, E.

    2018-02-01

    We analyze the results of spectral irradiance key comparison CCPR-K1.a for correlated color temperature (CCT). For four participants out of 13, the uncertainties of CCT, calculated using traditional methods, not accounting for correlations, would be too small. The reason for the failure of traditional uncertainty calculation is spectral correlations, producing systematic deviations of the same sign over certain wavelength regions. The results highlight the importance of accounting for such correlations when calculating uncertainties of spectrally integrated quantities.

  13. Interlaboratory Reproducibility and Proficiency Testing within the Human Papillomavirus Cervical Cancer Screening Program in Catalonia, Spain

    PubMed Central

    Ibáñez, R.; Félez-Sánchez, M.; Godínez, J. M.; Guardià, C.; Caballero, E.; Juve, R.; Combalia, N.; Bellosillo, B.; Cuevas, D.; Moreno-Crespi, J.; Pons, L.; Autonell, J.; Gutierrez, C.; Ordi, J.; de Sanjosé, S.

    2014-01-01

    In Catalonia, a screening protocol for cervical cancer, including human papillomavirus (HPV) DNA testing using the Digene Hybrid Capture 2 (HC2) assay, was implemented in 2006. In order to monitor interlaboratory reproducibility, a proficiency testing (PT) survey of the HPV samples was launched in 2008. The aim of this study was to explore the repeatability of the HC2 assay's performance. Participating laboratories provided 20 samples annually, 5 randomly chosen samples from each of the following relative light unit (RLU) intervals: <0.5, 0.5 to 0.99, 1 to 9.99, and ≥10. Kappa statistics were used to determine the agreement levels between the original and the PT readings. The nature and origin of the discrepant results were calculated by bootstrapping. A total of 946 specimens were retested. The kappa values were 0.91 for positive/negative categorical classification and 0.79 for the four RLU intervals studied. Sample retesting yielded systematically lower RLU values than the original test (P < 0.005), independently of the time elapsed between the two determinations (median, 53 days), possibly due to freeze-thaw cycles. The probability for a sample to show clinically discrepant results upon retesting was a function of the RLU value; samples with RLU values in the 0.5 to 5 interval showed 10.80% probability to yield discrepant results (95% confidence interval [CI], 7.86 to 14.33) compared to 0.85% probability for samples outside this interval (95% CI, 0.17 to 1.69). Globally, the HC2 assay shows high interlaboratory concordance. We have identified differential confidence thresholds and suggested the guidelines for interlaboratory PT in the future, as analytical quality assessment of HPV DNA detection remains a central component of the screening program for cervical cancer prevention. PMID:24574284

  14. In vitro to in vivo extrapolation of hepatic metabolism in fish: An inter-laboratory comparison of in vitro methods - presentation

    EPA Science Inventory

    Chemical biotransformation represents the largest source of uncertainty in chemical bioaccumulation assessments. Model-based estimates of chemical bioconcentration in fish may be greatly improved by including biotransformation rates, as measured in vitro. Substrate depletion assa...

  15. Centrally Determined Standardization of Flow Cytometry Methods Reduces Interlaboratory Variation in a Prospective Multicenter Study.

    PubMed

    Westera, Liset; van Viegen, Tanja; Jeyarajah, Jenny; Azad, Azar; Bilsborough, Janine; van den Brink, Gijs R; Cremer, Jonathan; Danese, Silvio; D'Haens, Geert; Eckmann, Lars; Faubion, William; Filice, Melissa; Korf, Hannelie; McGovern, Dermot; Panes, Julian; Salas, Azucena; Sandborn, William J; Silverberg, Mark S; Smith, Michelle I; Vermeire, Severine; Vetrano, Stefania; Shackelton, Lisa M; Stitt, Larry; Jairath, Vipul; Levesque, Barrett G; Spencer, David M; Feagan, Brian G; Vande Casteele, Niels

    2017-11-02

    Flow cytometry (FC) aids in characterization of cellular and molecular factors involved in pathologic immune responses. Although FC has potential to facilitate early drug development in inflammatory bowel disease, interlaboratory variability limits its use in multicenter trials. Standardization of methods may address this limitation. We compared variability in FC-aided quantitation of T-cell responses across international laboratories using three analytical strategies. Peripheral blood mononuclear cells (PBMCs) were isolated from three healthy donors, stimulated with phorbol 12-myristate 13-acetate and ionomycin at a central laboratory, fixed, frozen, and shipped to seven international laboratories. Permeabilization and staining was performed in triplicate at each laboratory using a common protocol and centrally provided reagents. Gating was performed using local gating with a local strategy (LGLS), local gating with a central strategy (LGCS), and central gating (CG). Median cell percentages were calculated across triplicates and donors, and reported for each condition and strategy. The coefficient of variation (CV) was calculated across laboratories. Between-strategy comparisons were made using a two-way analysis of variance adjusting for donor. Mean interlaboratory CV ranged from 1.8 to 102.1% depending on cell population and gating strategy (LGLS, 4.4-102.1%; LGCS, 10.9-65.6%; CG, 1.8-20.9%). Mean interlaboratory CV differed significantly across strategies and was consistently lower with CG. Central gating was the only strategy with mean CVs consistently lower than 25%, which is a proposed standard for pharmacodynamic and exploratory biomarker assays.

  16. An inter-laboratory comparison study of the ANSI/BIFMA standard test method M7.1 for furniture

    EPA Science Inventory

    Five laboratories using five different test chambers participated in the study to quantify within- and between-laboratory variability in the measurement of emissions of volatile organic compounds (VOCs) from new commercial furniture test items following ANSI/BIFMA M7.1. Test item...

  17. Evaluation of Methods for Analysis of Lead in Air Particulates: An Intra-Laboratory and Inter-Laboratory Comparison

    EPA Science Inventory

    In 2008, the United States Environmental Protection Agency (USEPA) set a new National Ambient Air Quality Standard (NAAQS) for lead (Pb) in total suspended particulate matter (Pb-TSP) which called for significant decreases in the allowable limits. The Federal Reference Method (FR...

  18. Inter-laboratory Comparison of Real-time PCR Methods for Quantification of General Fecal Indicator Bacteria

    EPA Science Inventory

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized prot...

  19. Interlaboratory Comparison of Real-time PCR Protocols for Quantification of General Fecal Indicator Bacteria

    EPA Science Inventory

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized proto...

  20. In vitro to In vivo extrapolation of hepatic metabolism in fish: An inter-laboratory comparison of In vitro methods

    EPA Science Inventory

    Chemical biotransformation represents the single largest source of uncertainty in chemical bioaccumulation assessments for fish. In vitro methods employing isolated hepatocytes and liver subcellular fractions (S9) can be used to estimate whole-body rates of chemical metabolism, ...

  1. Interlaboratory Comparison of Methods Determining the Botanical Composition of Animal Feed.

    PubMed

    Braglia, Luca; Morello, Laura; Gavazzi, Floriana; Gianì, Silvia; Mastromauro, Francesco; Breviario, Diego; Cardoso, Hélia Guerra; Valadas, Vera; Campos, Maria Doroteia

    2018-01-01

    A consortium of European enterprises and research institutions has been engaged in the Feed-Code Project with the aim of addressing the requirements stated in European Union Regulation No. 767/2009, concerning market placement and use of feed of known and ascertained botanical composition. Accordingly, an interlaboratory trial was set up to compare the performance of different assays based either on optical microscope or DNA analysis for the qualitative and quantitative identification of the composition of compound animal feeds. A tubulin-based polymorphism method, on which the Feed-Code platform was developed, provided the most accurate results. The present study highlights the need for the performance of ring trials for the determination of the botanical composition of animal feeds and raises an alarm on the actual status of analytical inaccuracy.

  2. Tools to minimize interlaboratory variability in vitellogenin gene expression monitoring programs

    USGS Publications Warehouse

    Jastrow, Aaron; Gordon, Denise A.; Auger, Kasie M.; Punska, Elizabeth C.; Arcaro, Kathleen F.; Keteles, Kristen; Winkelman, Dana L.; Lattier, David; Biales, Adam; Lazorchak, James M.

    2017-01-01

    The egg yolk precursor protein vitellogenin is widely used as a biomarker of estrogen exposure in male fish. However, standardized methodology is lacking and little is known regarding the reproducibility of results among laboratories using different equipment, reagents, protocols, and data analysis programs. To address this data gap we tested the reproducibility across laboratories to evaluate vitellogenin gene (vtg) expression and assessed the value of using a freely available software data analysis program. Samples collected from studies of male fathead minnows (Pimephales promelas) exposed to 17α-ethinylestradiol (EE2) and minnows exposed to processed wastewater effluent were evaluated for vtg expression in 4 laboratories. Our results indicate reasonable consistency among laboratories if the free software for expression analysis LinRegPCR is used, with 3 of 4 laboratories detecting vtg in fish exposed to 5 ng/L EE2 (n = 5). All 4 laboratories detected significantly increased vtg levels in 15 male fish exposed to wastewater effluent compared with 15 male fish held in a control stream. Finally, we were able to determine that the source of high interlaboratory variability from complementary deoxyribonucleic acid (cDNA) to quantitative polymerase chain reaction (qPCR) analyses was the expression analysis software unique to each real-time qPCR machine. We successfully eliminated the interlaboratory variability by reanalyzing raw fluorescence data with independent freeware, which yielded cycle thresholds and polymerase chain reaction (PCR) efficiencies that calculated results independently of proprietary software. Our results suggest that laboratories engaged in monitoring programs should validate their PCR protocols and analyze their gene expression data following the guidelines established in the present study for all gene expression biomarkers. 

  3. Interlaboratory comparison of δ13C and δD measurements of atmospheric CH4 for combined use of data sets from different laboratories

    NASA Astrophysics Data System (ADS)

    Umezawa, Taku; Brenninkmeijer, Carl A. M.; Röckmann, Thomas; van der Veen, Carina; Tyler, Stanley C.; Fujita, Ryo; Morimoto, Shinji; Aoki, Shuji; Sowers, Todd; Schmitt, Jochen; Bock, Michael; Beck, Jonas; Fischer, Hubertus; Michel, Sylvia E.; Vaughn, Bruce H.; Miller, John B.; White, James W. C.; Brailsford, Gordon; Schaefer, Hinrich; Sperlich, Peter; Brand, Willi A.; Rothe, Michael; Blunier, Thomas; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.; Rice, Andrew L.; Bergamaschi, Peter; Veidt, Cordelia; Levin, Ingeborg

    2018-03-01

    We report results from a worldwide interlaboratory comparison of samples among laboratories that measure (or measured) stable carbon and hydrogen isotope ratios of atmospheric CH4 (δ13C-CH4 and δD-CH4). The offsets among the laboratories are larger than the measurement reproducibility of individual laboratories. To disentangle plausible measurement offsets, we evaluated and critically assessed a large number of intercomparison results, some of which have been documented previously in the literature. The results indicate significant offsets of δ13C-CH4 and δD-CH4 measurements among data sets reported from different laboratories; the differences among laboratories at modern atmospheric CH4 level spread over ranges of 0.5 ‰ for δ13C-CH4 and 13 ‰ for δD-CH4. The intercomparison results summarized in this study may be of help in future attempts to harmonize δ13C-CH4 and δD-CH4 data sets from different laboratories in order to jointly incorporate them into modelling studies. However, establishing a merged data set, which includes δ13C-CH4 and δD-CH4 data from multiple laboratories with desirable compatibility, is still challenging due to differences among laboratories in instrument settings, correction methods, traceability to reference materials and long-term data management. Further efforts are needed to identify causes of the interlaboratory measurement offsets and to decrease those to move towards the best use of available δ13C-CH4 and δD-CH4 data sets.

  4. 77 FR 29757 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-18

    ... Discharge Elimination System (NPDES) program, issue permits with conditions designed to ensure compliance... completion of a full inter-laboratory validation study designed to fully characterize the performance of...

  5. Centrally Determined Standardization of Flow Cytometry Methods Reduces Interlaboratory Variation in a Prospective Multicenter Study

    PubMed Central

    Westera, Liset; van Viegen, Tanja; Jeyarajah, Jenny; Azad, Azar; Bilsborough, Janine; van den Brink, Gijs R; Cremer, Jonathan; Danese, Silvio; D'Haens, Geert; Eckmann, Lars; Faubion, William; Filice, Melissa; Korf, Hannelie; McGovern, Dermot; Panes, Julian; Salas, Azucena; Sandborn, William J; Silverberg, Mark S; Smith, Michelle I; Vermeire, Severine; Vetrano, Stefania; Shackelton, Lisa M; Stitt, Larry; Jairath, Vipul; Levesque, Barrett G; Spencer, David M; Feagan, Brian G; Vande Casteele, Niels

    2017-01-01

    Objectives: Flow cytometry (FC) aids in characterization of cellular and molecular factors involved in pathologic immune responses. Although FC has potential to facilitate early drug development in inflammatory bowel disease, interlaboratory variability limits its use in multicenter trials. Standardization of methods may address this limitation. We compared variability in FC-aided quantitation of T-cell responses across international laboratories using three analytical strategies. Methods: Peripheral blood mononuclear cells (PBMCs) were isolated from three healthy donors, stimulated with phorbol 12-myristate 13-acetate and ionomycin at a central laboratory, fixed, frozen, and shipped to seven international laboratories. Permeabilization and staining was performed in triplicate at each laboratory using a common protocol and centrally provided reagents. Gating was performed using local gating with a local strategy (LGLS), local gating with a central strategy (LGCS), and central gating (CG). Median cell percentages were calculated across triplicates and donors, and reported for each condition and strategy. The coefficient of variation (CV) was calculated across laboratories. Between-strategy comparisons were made using a two-way analysis of variance adjusting for donor. Results: Mean interlaboratory CV ranged from 1.8 to 102.1% depending on cell population and gating strategy (LGLS, 4.4–102.1% LGCS, 10.9–65.6% CG, 1.8–20.9%). Mean interlaboratory CV differed significantly across strategies and was consistently lower with CG. Conclusions: Central gating was the only strategy with mean CVs consistently lower than 25%, which is a proposed standard for pharmacodynamic and exploratory biomarker assays. PMID:29095427

  6. Key Lessons from Performance of the U.S. EPA Endocrine Disruptor Screening Program (EDSP) Tier 1 Male and Female Pubertal Assays

    PubMed Central

    Stump, Donald G; O'Connor, John C; Lewis, Joseph M; Marty, M Sue

    2014-01-01

    The male and female pubertal assays, which are included in the U.S. Environmental Protection Agency's (EPA) Endocrine Disruptor Screening Program (EDSP) Tier 1 battery, can detect endocrine-active compounds operating by various modes of action. This article uses the collective experience of three laboratories to provide information on pubertal assay conduct, interlaboratory reproducibility, endpoint redundancy, and data interpretation. The various criteria used to select the maximum tolerated dose are described. A comparison of historical control data across laboratories confirmed reasonably good interlaboratory reproducibility. With a reliance on apical endpoints, interpretation of pubertal assay effects as specifically endocrine-mediated or secondary to other systemic effects can be problematic and mode of action may be difficult to discern. Across 21–23 data sets, relative liver weight, a nonspecific endocrine endpoint, was the most commonly affected endpoint in male and female assays. For endocrine endpoints, patterns of effects were generally seen; rarely was an endocrine-sensitive endpoint affected in isolation. In males, most frequently missed EPA-established performance criteria included mean weights for kidney and thyroid, and the coefficient of variation for age and body weight at preputial separation, seminal vesicle weight, and final body weight. In females, the frequently missed EPA-established performance criteria included mean adrenal weight and mean age at vaginal opening. To ensure specificity for endocrine effects, the pubertal assays should be interpreted using a weight-of-evidence approach as part of the entire EDSP battery. Based on the frequency with which certain performance criteria were missed, an EPA review of these criteria is warranted. PMID:24510766

  7. COMPARISON AND EVALUATION OF LABORATORY PERFORMANCE ON A METHOD FOR THE DETERMINATION OF PERCHLORATE IN FERTILIZERS

    EPA Science Inventory

    This report details the interlaboratory validation of a method for the determination of perchlorate in fertilizers. In this method (EPA/600/R-01/026), a solid sample of fertilizer is first ground. subsequently, the ground material is either leached with deionized water to dissolv...

  8. OVERVIEW OF AN INTERLABORATORY COLLABORATION ON EVALUATING THE EFFECTS OF MODEL HEPATOTOXICANTS ON HEPATIC GENE EXPRESSION

    EPA Science Inventory

    Evaluating the Effects of Methapyrilene and Clofibrate on Hepatic Gene Expression: A Collaboration Between Laboratories and a Comparison of Platform and Analytical Approaches

    Roger G. Ulrich1, John C. Rockett2, G. Gordon Gibson3 and Syril Pettit4

    1 Rosetta Inpharmat...

  9. CHARACTERIZATION OF FINE PARTICLE ASSOCIATED ORGANIC COMPOUNDS: INTERLABORATORY COMPARISON AND DEVELOPMENT OF STANDARD REFERENCE MATERIALS

    EPA Science Inventory

    Organic chemicals adsorbed to fine particulate matter (PM) in the ambient air account for a major component of the mass and include source tracers as well as toxic compounds that may contribute to adverse human health effects. The US EPA has established a PM 2.5 research progr...

  10. External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 1995-96

    USGS Publications Warehouse

    Gordon, John D.

    1999-01-01

    The U.S. Geological Survey operated four external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) in 1995 and 1996: the intersite-comparison program, the blind-audit program, the interlaboratory- comparison program, and the collocated-sampler program. The intersite-comparison program assessed the precision and bias of pH and specific-conductance determinations made by NADP/NTN site operators. The analytical bias introduced during routine handling, processing, and shipping of wet-deposition samples and precision of analyte values was estimated using a blind-audit program. An interlaboratory-comparison program was used to evaluate differences between analytical results and to estimate the analytical precision of five North American laboratories that routinely analyzed wet deposition. A collocated-sampler program estimated the precision of the overall precipitation collection and analysis system from initial sample collection through final storage of the data. Results of two intersite-comparison studies completed in 1995 indicated 94.6 and 94.4 percent of the onsite pH determinations met the NADP/NTN accuracy goals, whereas 97.2 and 98.3 percent of the specific-conductance determinations were within the established limits. The percentages of onsite determinations that met the accuracy goals in 1996 were slightly less for both pH and specific-conductance than in 1995. In 1996, 93.2 and 87.5 percent of onsite pH determinations met the accuracy goals, whereas the percentage of onsite specific-conductance measurements that met the goals was 93.9 and 94.9 percent.The blind audit program utilizes a paired sample design to evaluate the effects of routine sample handling, processing and shipping on the chemistry of weekly precipitation samples. The portion of the blind audit sample subject to all of the normal onsite handling and processing steps of a regular weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Throughout the report, the term positive bias in regard to blind-audit results indicates that the bucket portion had a higher concentration than the bottle portion. The paired t-test of 1995 blind-audit data indicated that routine sample handling, processing, and shipping introduced a very small positive bias (a=0.05) for hydrogen ion and specific conductance and a slight negative bias (a =0.05) for ammonium and sodium. In 1995, the median paired differences between the bucket and bottle portions ranged from -0.02 milligram per liter for both ammonium and nitrate to +0.002 milligram per liter for calcium. Although the paired t-test indicated a very small positive bias for hydrogen ion, the median paired difference between the bucket and bottle portions was 0.00 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was 0.200 microsiemens per centimeter in 1995. The paired t-test of blind-audit results in 1996 indicated statistically significant bias for 6 of the 10 analytes. Only chloride, nitrate, hydrogen ion, and specific conductance were not biased in 1996. However, the magnitude of the bias in 1996 was very small and only of limited importance from the viewpoint of an analytical chemist or data user. The median paired differences between the bucket and bottle portions ranged from -0.02 milligram per liter for both ammonium and chloride to +0.006 milligram per liter for calcium. For hydrogen ion, the median paired difference between the bucket and bottle portions was -0.357 microequivalent per liter; for specific conductance, the median paired difference between the bucket and bottle portions was 0.00 microsiemens per centimeter in 1996. Surface-chemistry effects due to different amounts of precipitation contacting the sample collection and shipping container surfac

  11. Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.

    PubMed

    Pestle, William J; Crowley, Brooke E; Weirauch, Matthew T

    2014-01-01

    Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values. To address the issues arising from inter-laboratory comparisons, we devise a novel measure we term the Minimum Meaningful Difference (MMD), and demonstrate its application.

  12. Quantifying Inter-Laboratory Variability in Stable Isotope Analysis of Ancient Skeletal Remains

    PubMed Central

    Pestle, William J.; Crowley, Brooke E.; Weirauch, Matthew T.

    2014-01-01

    Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values. To address the issues arising from inter-laboratory comparisons, we devise a novel measure we term the Minimum Meaningful Difference (MMD), and demonstrate its application. PMID:25061843

  13. Interlaboratory comparison of immunohistochemical testing for HER2: results of the 2004 and 2005 College of American Pathologists HER2 Immunohistochemistry Tissue Microarray Survey.

    PubMed

    Fitzgibbons, Patrick L; Murphy, Douglas A; Dorfman, David M; Roche, Patrick C; Tubbs, Raymond R

    2006-10-01

    Correct assessment of human epidermal growth factor receptor 2 (HER2) status is essential in managing patients with invasive breast carcinoma, but few data are available on the accuracy of laboratories performing HER2 testing by immunohistochemistry (IHC). To review the results of the 2004 and 2005 College of American Pathologists HER2 Immunohistochemistry Tissue Microarray Survey. The HER2 survey is designed for laboratories performing immunohistochemical staining and interpretation for HER2. The survey uses tissue microarrays, each consisting of ten 3-mm tissue cores obtained from different invasive breast carcinomas. All cases are also analyzed by fluorescence in situ hybridization. Participants receive 8 tissue microarrays (80 cases) with instructions to perform immunostaining for HER2 using the laboratory's standard procedures. The laboratory interprets the stained slides and returns results to the College of American Pathologists for analysis. In 2004 and 2005, a core was considered "graded" when at least 90% of laboratories agreed on the result--negative (0, 1+) versus positive (2+, 3+). This interlaboratory comparison survey included 102 laboratories in 2004 and 141 laboratories in 2005. Of the 160 cases in both surveys, 111 (69%) achieved 90% consensus (graded). All 43 graded cores scored as IHC-positive were fluorescence in situ hybridization-positive, whereas all but 3 of the 68 IHC-negative graded cores were fluorescence in situ hybridization-negative. Ninety-seven (95%) of 102 laboratories in 2004 and 129 (91%) of 141 laboratories in 2005 correctly scored at least 90% of the graded cores. Performance among laboratories performing HER2 IHC in this tissue microarray-based survey was excellent. Cores found to be IHC-positive or IHC-negative by participant consensus can be used as validated benchmarks for interlaboratory comparison, allowing laboratories to assess their performance and determine if improvements are needed.

  14. Evaluation of Brazilian Sugarcane Bagasse Characterization: An Interlaboratory Comparison Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sluiter, Justin B.; Chum, Helena; Gomes, Absai C.

    2016-05-01

    This paper describes a study of the variability of measured composition for a single bulk sugarcane bagasse conducted across eight laboratories using similar analytical methods, with the purpose of determining the expected variation for compositional analysis performed by different laboratories. The results show good agreement of measured composition within a single laboratory, but greater variability when results are compared among laboratories. These interlaboratory variabilities do not seem to be associated with a specific method or technique or any single piece of instrumentation. The summary censored statistics provide mean values and pooled standard deviations as follows: total extractives 6.7% (0.6%), wholemore » ash 1.5% (0.2%), glucan 42.3% (1.2%), xylan 22.3% (0.5%), total lignin 21.3% (0.4%), and total mass closure 99.4% (2.9%).« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindahl, P.C.

    A proposed American Society for Testing and Materials (ASTM) method for the determination of arsenic and selenium content in coal has been used and evaluated in the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) as part of an interlaboratory study. Coal is conducted with Eschka's mixture (MgO + Na/sub 2/CO/sub 3/), followed by determination of the aresnic and selenium content by hydride generation/atomic absorption spectrophotometry. The method was evaluated on a series of coals, including two National Bureau of Standards-Standards Reference Material (NBS-SRM) coals and twelve ASTM coal samples. Comparison of ACL/ANL arsenic and selenium data for themore » suite of coal analyzed showed excellent agreement with certified values for the NBS-SRM coals and with interlaboratory data from five other laboratories for the ASTM coals. 11 refs., 3 figs., 6 tabs.« less

  16. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Infrared spectral normal emittance/emissivity comparison

    NASA Astrophysics Data System (ADS)

    Hanssen, L.; Wilthan, B.; Filtz, J.-R.; Hameury, J.; Girard, F.; Battuello, M.; Ishii, J.; Hollandt, J.; Monte, C.

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Quality Assurance and Control Considerations in Environmental Measurements and Monitoring

    NASA Astrophysics Data System (ADS)

    Sedlet, Jacob

    1982-06-01

    Quality assurance and quality control have become accepted as essential parts of all environmental surveillance, measurements, and monitoring programs, both nuclear and non-nuclear. The same principles and details apply to each. It is primarily the final measurement technique that differs. As the desire and need to measure smaller amounts of pollutants with greater accuracy has increased, it has been recognized that quality assurance and control programs are cost-effective in achieving the expected results. Quality assurance (QA) consists of all the actions necessary to provide confidence in the results. Quality control (QC) is a part of QA, and consists of those actions and activities that permit the control of the individual steps in the environmental program. The distinction between the two terms is not always clearly defined, but a sharp division is not necessary. The essential principle of QA and QC is a commitment to high quality results. The essential components of a QA and QC program are a complete, written procedures manual for all parts of the environmental program, the use of standard or validated procedures, participation in applicable interlaboratory comparison or QA programs, replicate analysis and measurement, training of personnel, and a means of auditing or checking that the QA and QC programs are properly conducted. These components are discussed below in some detail.

  19. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    PubMed

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  20. Interlaboratory comparison of three microbial source tracking quantitative polymerase chain reaction (qPCR) assays from fecal-source and environmental samples

    USGS Publications Warehouse

    Stelzer, Erin A.; Strickler, Kriston M.; Schill, William B.

    2012-01-01

    During summer and early fall 2010, 15 river samples and 6 fecal-source samples were collected in West Virginia. These samples were analyzed by three laboratories for three microbial source tracking (MST) markers: AllBac, a general fecal indicator; BacHum, a human-associated fecal indicator; and BoBac, a ruminant-associated fecal indicator. MST markers were analyzed by means of the quantitative polymerase chain reaction (qPCR) method. The aim was to assess interlaboratory precision when the three laboratories used the same MST marker and shared deoxyribonucleic acid (DNA) extracts of the samples, but different equipment, reagents, and analyst experience levels. The term assay refers to both the markers and the procedure differences listed above. Interlaboratory precision was best for all three MST assays when using the geometric mean absolute relative percent difference (ARPD) and Friedman's statistical test as a measure of interlaboratory precision. Adjustment factors (one for each MST assay) were calculated using results from fecal-source samples analyzed by all three laboratories and applied retrospectively to sample concentrations to account for differences in qPCR results among labs using different standards and procedures. Following the application of adjustment factors to qPCR results, ARPDs were lower; however, statistically significant differences between labs were still observed for the BacHum and BoBac assays. This was a small study and two of the MST assays had 52 percent of samples with concentrations at or below the limit of accurate quantification; hence, more testing could be done to determine if the adjustment factors would work better if the majority of sample concentrations were above the quantification limit.

  1. Tools to minimize interlaboratory variability in vitellogenin gene expression monitoring programs

    EPA Science Inventory

    The egg yolk precursor protein vitellogenin is widely used as a biomarker of estrogen exposure in male fish. However, standardized methodology is lacking and little is known regarding the reproducibility of results among laboratories using different equipment, reagents, protocols...

  2. Automation of metabolic stability studies in microsomes, cytosol and plasma using a 215 Gilson liquid handler.

    PubMed

    Linget, J M; du Vignaud, P

    1999-05-01

    A 215 Gilson liquid handler was used to automate enzymatic incubations using microsomes, cytosol and plasma. The design of automated protocols are described. They were based on the use of 96 deep well plates and on HPLC-based methods for assaying the substrate. The assessment of those protocols was made with comparison between manual and automated incubations, reliability and reproducibility of automated incubations in microsomes and cytosol. Examples of the use of those programs in metabolic studies in drug research, i.e. metabolic screening in microsomes and plasma were shown. Even rapid processes (with disappearance half lives as low as 1 min) can be analysed. This work demonstrates how stability studies can be automated to save time, render experiments involving human biological media less hazardous and may be improve inter-laboratory reproducibility.

  3. Use of the rapid immersion test to evaluate the efficacy of admixtures to mitigate alkali-silica reactivity.

    DOT National Transportation Integrated Search

    1996-01-01

    The Federal Highway Administration (FHWA) is conducting an interlaboratory study to validate certain findings in the Strategic Highway Research Program (SHRP) C-343 report on alkali-silica reactivity. This paper reports the Virginia Transportation Re...

  4. [Inter-laboratory reproducibility of pulsed-field electrophoresis for the study of 12 types of Pseudomonas aeruginosa].

    PubMed

    Foissaud, V; Puyhardy, J M; Chapalain, J C; Salord, H; Depina, J J; Morillon, M; Nicolas, P; Perrier-Gros-Claude, J D

    1999-12-01

    The increasing hospital-to-hospital transmission of multiple drug-resistant bacteria is a major concern for bacteriology laboratories involved in nosocomial infection control. The interlaboratory reproducibility of pulsed-field gel electrophoresis (PFGE) for Pseudomonas aeruginosa typing was evaluated by asking four hospital laboratories (two in Lyon, one in Brest, and one in Marseille) to study 11 P. aeruginosa isolates, some of which were epidemiologically related, and the reference strain ATCC 27853. Two laboratories used the Genepath system, one the Chef DR II, system, and one the Chef Mapper system, Bio-Rad, restriction/Spe I. Profiles were read visually and by computerized comparison of restriction band molecular weights (Taxotron, software, PAD Grimont, Pasteur Institute, Paris, France). These two methods led to similar epidemiological conclusions. However, centralization of the data showed poor center-to-center reproducibility due to inadequate standardization of the procedure.

  5. Inter-laboratory variation in the chemical analysis of acidic forest soil reference samples from eastern North America

    Treesearch

    D.S. Ross; S.W. Bailey; R.D. Briggs; J. Curry; I.J. Fernandez; G. Fredriksen; C.L. Goodale; P.W. Hazlett; P.R. Heine; C.E. Johnson; J.T. Larson; G.B. Lawrence; R.K. Kolka; R. Ouimet; D. Pare; D. deB Richter; C.D. Schirmer; R.A. Warby

    2015-01-01

    Long-term forest soil monitoring and research often requires a comparison of laboratory data generated at different times and in different laboratories. Quantifying the uncertainty associated with these analyses is necessary to assess temporal changes in soil properties. Forest soil chemical properties, and methods to measure these properties, often differ from...

  6. Comparisons of interlaboratory swellometer testing of two water-repellent preservative formulations for millwork

    Treesearch

    Elmer L. Schmidt; Timothy P. Murphy; Charles N. Cheeks; Alan S. Ross; T. S. (Eugene) Chiu; R. Sam Williams

    2002-01-01

    Water-repellency of preservative formulations used in the millwork industry has long been evaluated by measurement of the dimensional changes in wood treated and then submerged in water according to guidelines published by the millwork industry. Perceptions that this swellometer test was highly variable led to a round-robin test of one solvent-borne and one waterborne...

  7. NanoRelease: Pilot interlaboratory comparison of a weathering protocol applied to resilient and labile polymers with and without embedded carbon nanotubes

    EPA Science Inventory

    A major use of multi-walled carbon nanotubes (MWCNTs) is as functional fillers embedded in a solid matrix, such as plastics or coatings. Weathering and abrasion of the solid matrix during use can lead to environmental releases of the MWCNTs. Here we focus on a protocol to identif...

  8. Measurement of dissolved organic matter fluorescense in aquatic environments: An interlaboratory comparison

    USGS Publications Warehouse

    Murphy, Kathleen R.; Butler, Kenna D.; Spencer, Robert G. M.; Stedmon, Colin A.; Boehme, Jennifer R.; Aiken, George R.

    2010-01-01

    The fluorescent properties of dissolved organic matter (DOM) are often studied in order to infer DOM characteristics in aquatic environments, including source, quantity, composition, and behavior. While a potentially powerful technique, a single widely implemented standard method for correcting and presenting fluorescence measurements is lacking, leading to difficulties when comparing data collected by different research groups. This paper reports on a large-scale interlaboratory comparison in which natural samples and well-characterized fluorophores were analyzed in 20 laboratories in the U.S., Europe, and Australia. Shortcomings were evident in several areas, including data quality-assurance, the accuracy of spectral correction factors used to correct EEMs, and the treatment of optically dense samples. Data corrected by participants according to individual laboratory procedures were more variable than when corrected under a standard protocol. Wavelength dependency in measurement precision and accuracy were observed within and between instruments, even in corrected data. In an effort to reduce future occurrences of similar problems, algorithms for correcting and calibrating EEMs are described in detail, and MATLAB scripts for implementing the study's protocol are provided. Combined with the recent expansion of spectral fluorescence standards, this approach will serve to increase the intercomparability of DOM fluorescence studies.

  9. Interlaboratory comparison measurements of aspheres

    NASA Astrophysics Data System (ADS)

    Schachtschneider, R.; Fortmeier, I.; Stavridis, M.; Asfour, J.; Berger, G.; Bergmann, R. B.; Beutler, A.; Blümel, T.; Klawitter, H.; Kubo, K.; Liebl, J.; Löffler, F.; Meeß, R.; Pruss, C.; Ramm, D.; Sandner, M.; Schneider, G.; Wendel, M.; Widdershoven, I.; Schulz, M.; Elster, C.

    2018-05-01

    The need for high-quality aspheres is rapidly growing, necessitating increased accuracy in their measurement. A reliable uncertainty assessment of asphere form measurement techniques is difficult due to their complexity. In order to explore the accuracy of current asphere form measurement techniques, an interlaboratory comparison was carried out in which four aspheres were measured by eight laboratories using tactile measurements, optical point measurements, and optical areal measurements. Altogether, 12 different devices were employed. The measurement results were analysed after subtracting the design topography and subsequently a best-fit sphere from the measurements. The surface reduced in this way was compared to a reference topography that was obtained by taking the pointwise median across the ensemble of reduced topographies on a 1000 × 1000 Cartesian grid. The deviations of the reduced topographies from the reference topography were analysed in terms of several characteristics including peak-to-valley and root-mean-square deviations. Root-mean-square deviations of the reduced topographies from the reference topographies were found to be on the order of some tens of nanometres up to 89 nm, with most of the deviations being smaller than 20 nm. Our results give an indication of the accuracy that can currently be expected in form measurements of aspheres.

  10. Evaluation of platelet adhesion and activation on polymers: Round-robin study to assess inter-center variability.

    PubMed

    Braune, S; Sperling, C; Maitz, M F; Steinseifer, U; Clauser, J; Hiebl, B; Krajewski, S; Wendel, H P; Jung, F

    2017-10-01

    The regulatory agencies provide recommendations rather than protocols or standard operation procedures for the hemocompatibility evaluation of novel materials e.g. for cardiovascular applications. Thus, there is a lack of specifications with regard to test setups and procedures. As a consequence, laboratories worldwide perform in vitro assays under substantially different test conditions, so that inter-laboratory and inter-study comparisons are impossible. Here, we report about a prospective, randomized and double-blind multicenter trial which demonstrates that standardization of in vitro test protocols allows a reproducible assessment of platelet adhesion and activation from fresh human platelet rich plasma as possible indicators of the thrombogenicity of cardiovascular implants. Standardization of the reported static in vitro setup resulted in a laboratory independent scoring of the following materials: poly(dimethyl siloxane) (PDMS), poly(ethylene terephthalate) (PET) and poly(tetrafluoro ethylene) (PTFE). The results of this in vitro study provide evidence that inter-laboratory and inter-study comparisons can be achieved for the evaluation of the adhesion and activation of platelets on blood-contacting biomaterials by stringent standardization of test protocols. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Canine and feline hematology reference values for the ADVIA 120 hematology system.

    PubMed

    Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J

    2004-01-01

    The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.

  12. Predictive performance and inter-laboratory reproducibility in assessing eye irritation potential of water- and oil-soluble mixtures using the Short Time Exposure test method.

    PubMed

    Abo, Takayuki; Hilberer, Allison; Behle-Wagner, Christine; Watanabe, Mika; Cameron, David; Kirst, Annette; Nukada, Yuko; Yuki, Takuo; Araki, Daisuke; Sakaguchi, Hitoshi; Itagaki, Hiroshi

    2018-04-01

    The Short Time Exposure (STE) test method is an alternative method for assessing eye irritation potential using Statens Seruminstitut Rabbit Cornea cells and has been adopted as test guideline 491 by the Organisation for Economic Co-operation and Development. Its good predictive performance in identifying the Globally Harmonized System (GHS) No Category (NC) or Irritant Category has been demonstrated in evaluations of water-soluble substances, oil-soluble substances, and water-soluble mixtures. However, the predictive performance for oil-soluble mixtures was not evaluated. Twenty-four oil-soluble mixtures were evaluated using the STE test method. The GHS NC or Irritant Category of 22 oil-soluble mixtures were consistent with that of a Reconstructed human Cornea-like Epithelium (RhCE) test method. Inter-laboratory reproducibility was then confirmed using 20 water- and oil-soluble mixtures blind-coded. The concordance in GHS NC or Irritant Category among four laboratories was 90%-100%. In conclusion, the concordance in comparison with the results of RhCE test method using 24 oil-soluble mixtures and inter-laboratory reproducibility using 20 water- and oil-soluble mixtures blind-coded were good, indicating that the STE test method is a suitable alternative for predicting the eye irritation potential of both substances and mixtures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Interlaboratory trial for measurement of vitamin D and 25(OH)D in foods and a dietary supplement using liquid chromatography-mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    Assessment of total vitamin D intake from foods and dietary supplements (DSs) may be incomplete if 25-hydroxyvitamin D [25(OH)D] intake is not included. However, 25(OH)D data for such intake assessments are lacking, no food or DS reference materials (RMs) are available, and comparison of laboratory...

  14. Elemental analysis of forensic glasses by inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Almirall, Jose R.; Duckworth, Douglas C.; Bayne, Charles K.; Morton, Sherman A.; Smith, David H.; Koons, Robert D.; Furton, Kenneth G.

    1999-02-01

    Flat glass is a common type of evidence collected from the scenes of crimes such as burglaries, vandalism, and hit-and- run accidents. The usefulness of such evidence lies in the ability to associate the glass from the scene (or a suspect) to the original source. Physical and chemical analysis of the glass can be used for discrimination between the possible sources of glass. If the sample is large enough, physical attributes such as fracture matches, density, color, and thickness can be employed for comparison between a recovered fragment(s) to the suspect source. More commonly, refractive index (RI) comparisons are employed. Due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses where approximately 6 - 9% of casework samples are not expected to be distinguished by RI alone even if they originated from different sources. Employing methods such as NAA, XRF, ICP-AES, and ICP-MS for the comparison of trace elemental compositions has been shown to be more discriminating than RI comparisons. The multielement capability and the sensitivity of ICP-AES and ICP-MS provide for excellent discrimination power. In this work, the sources of variability in ICP-MS of glass analysis are investigated to determine possible sources of variation. The sources of variation examined include errors due to sample preparation, instrument accuracy and precision, and interlaboratory reproducibility. Other sources of variation include inhomogeneity across a sheet of glass from the same source. Analysis of variance has been applied to our ICP-MS analysis of NIST standards and to the interlaboratory comparisons of float glass samples collected across a sheet in a production facility. The results of these experiments allows for a more accurate interpretation of forensic glass data and a better understanding of the discriminating power (absolute and practical) of ICP-MS.

  15. Use of allogeneic apheresis stem cell products as an interlaboratory proficiency challenge.

    PubMed

    Cooling, Laura; Roxbury, Kelly; Hoffmann, Sandra; DeBusscher, Joan; Kota, Usha; Goldstein, Steven; Davenport, Robertson

    2017-06-01

    AABB Standards requires that laboratories participate in a proficiency test (PT) program for critical analytes. Institutions can purchase commercial PT materials; however, PT can also be performed through interlaboratory exchange. We investigated the utility of allogeneic hematopoietic progenitor cell apheresis (HPC-A) products as an interlaboratory PT challenge for total nucleated cell count (TNC) and CD34 assessment. Three-year retrospective and comparative review of unrelated allogeneic HPC-A products received by the University of Michigan between January 2011 and December 2013. Internal TNC and CD34 count were compared to the external collecting facility by paired t test and linear regression. The absolute and percent difference between external and internal counts and 95% limits of agreeability (95% LA) were determined. Results were analyzed relative to donor center location (international, domestic), time zone (domestic), and calendar year. There was a strong correlation between internal and external TNC, regardless of donor center location or year. For CD34, there was a good correlation between centers (R = 0.88-0.91; slope = 0.95-0.98x) with a median difference of -1% (95% LA, -50%, +47%). This was considerably better than commercial PT challenges, which showed a persistent negative bias for absolute CD34 and CD3 counts. Allogeneic HPC-A products represent an interlaboratory PT exchange for all critical analytes, including TNC and CD34 count, cell viability, and sterility. Allogeneic HPC-A products, which are fresh and transported under validated conditions, are less subject to preanalytical variables that may impact commercial PT samples such as aliquoting and sample homogeneity, commercial additives, and sample stability during manufacturing and transport. © 2017 AABB.

  16. Experimental design of an interlaboratory study for trace metal analysis of liquid fluids. [for aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Greenbauer-Seng, L. A.

    1983-01-01

    The accurate determination of trace metals and fuels is an important requirement in much of the research into and development of alternative fuels for aerospace applications. Recognizing the detrimental effects of certain metals on fuel performance and fuel systems at the part per million and in some cases part per billion levels requires improved accuracy in determining these low concentration elements. Accurate analyses are also required to ensure interchangeability of analysis results between vendor, researcher, and end use for purposes of quality control. Previous interlaboratory studies have demonstrated the inability of different laboratories to agree on the results of metal analysis, particularly at low concentration levels, yet typically good precisions are reported within a laboratory. An interlaboratory study was designed to gain statistical information about the sources of variation in the reported concentrations. Five participant laboratories were used on a fee basis and were not informed of the purpose of the analyses. The effects of laboratory, analytical technique, concentration level, and ashing additive were studied in four fuel types for 20 elements of interest. The prescribed sample preparation schemes (variations of dry ashing) were used by all of the laboratories. The analytical data were statistically evaluated using a computer program for the analysis of variance technique.

  17. An Update to the EARTHTIME Argon Intercalibration Pipette System (APIS): Smoking from the Same Pipe

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Swisher, C. C., III; Hemming, S. R.; Renne, P. R.; Deino, A. L.; Hodges, K. V.; Van Soest, M. C.; Heizler, M. T.

    2015-12-01

    Background: An initial 40Ar/39Ar inter-calibration experiment, using two of the most commonly used 40Ar/39Ar mineral standards, Fish Canyon (FC, ~28.2 Ma) and Alder Creek (AC, ~1.2 Ma) sanidines, revealed significant inter-laboratory inconsistencies. The reported ages for the AC sanidines range from 1.173 to 1.200 Ma (FC 28.02) (±~2%), ~4 times greater than the reported precisions. These experiments have motivated the 40Ar/39Ar community to reevaluate procedures and subsequent informal lab intercalibrations experiments are in better agreement, but discrepancies remain that need to be addressed. Experiment: In an effort to isolate the causes of these inconsistencies, an Argon Intercalibration Pipette System (APIS) was designed and constructed. The APIS system consists of three gas canisters; one containing atmospheric Ar and the other two canisters contain 40Ar/39Ar ratios that represent FC and AC. The volumes of the pipettes, bulbs and manifold are determined to within 0.4% and both systems were initially filled to the same pressure with Ar standard gases. Each canister has 4x10-10 moles of 40Ar, is equipped with a 0.1, 0.2 and 0.4 cc pipettes and can deliver increments from 0.1-0.7 cc. APIS-1 was designated as the traveling unit that is brought to participating labs, APIS-2 is the reserve/master standard. Early Results and Impressions: APIS-1 has been to four labs (Rutgers, LDEO, New Mexico Tech, and BGC) and is heading to ASU. Early APIS experimental data indicate that the inter-laboratory 40Ar/39Ar age results can meet or exceed the EARTHTIME goal of ±1‰ precision. The inter-laboratory comparisons are ongoing, and will include additional laboratories of opportunity. Lastly, the development of additional mineral standards that "fill in" the age gaps between the existing mineral standards would significantly improve attempting to achieve interlaboratory agreement at the ±1‰ level

  18. Argon Intercalibration Pipette System (APIS): Smoking from the Same Pipe

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Swisher, C. C., III; Hemming, S. R.; Renne, P. R.; Deino, A. L.; Hodges, K. V.; Van Soest, M. C.; Heizler, M. T.

    2014-12-01

    40Ar/39Ar age inter-calibration experiments, conducted as part of the US NSF sponsored EARTHTIME initiative, (http://www.earth-time.org), using two of the most commonly used 40Ar/39Ar mineral standards, Fish Canyon (FC, ~28.2 Ma) and Alder Creek (AC, ~1.2 Ma) sanidines, have revealed significant inter-laboratory inconsistencies. The reported ages for the AC sanidines range from 1.173 to 1.200 Ma (FC 28.02) (±~2%), ~4 times greater than the reported precision. These experiments have caused the 40Ar/39Ar community to scrutinize procedures and several informal lab intercalibrations have been conducted among different labs. This exercise is leading to better agreement, but discrepancies remain that need to be addressed. In an effort to isolate the cause(s) of these inconsistencies, two Argon Inter-calibration Pipette System (APIS) were designed and constructed. Each consists of three gas canisters; one contains atmospheric Ar, while the other two contain artificial gas mixtures with 40Ar/39Ar ratios similar to those of FC and AC. Each canister has 4x10-10 moles of 40Ar, is equipped with 0.1, 0.2 and 0.4 cc pipettes, and can deliver gas volumes from 0.1-0.7 cc. All volumes were determined manometrically to 0.4% or better and then filled to uniform pressure with Ar standard gases. This experimental design eliminates sample heterogeneity, leaving only interlaboratory variations in gas purification, data reduction, and isotopic measurement as potential sources of interlaboratory calibration discrepancies. APIS-1 was designated as a traveling unit that is brought to participating labs. APIS-2 is the reserve/master standard. Currently, APIS-1 is in its early stages in the voyage and has been to three labs (Rutgers, LDEO, and New Mexico Tech) as of this writing. The interlaboratory comparisons are ongoing, and will include ASU, BGC, Univ. of Wisconsin, and Oregon State University, plus additional laboratories of opportunity. A progress report will be presented at AGU.

  19. Receptor binding assay for paralytic shellfish poisoning toxins: optimization and interlaboratory comparison.

    PubMed

    Ruberu, Shryamalie R; Liu, Yun-Gang; Wong, Carolyn T; Perera, S Kusum; Langlois, Gregg W; Doucette, Gregory J; Powell, Christine L

    2003-01-01

    A receptor binding assay (RBA) for detection of paralytic shellfish poisoning (PSP) toxins was formatted for use in a high throughput detection system using microplate scintillation counting. The RBA technology was transferred from the National Ocean Service, which uses a Wallac TriLux 1450 MicroBeta microplate scintillation counter, to the California Department of Health Services, which uses a Packard TopCount scintillation counter. Due to differences in the detector arrangement between these 2 counters, markedly different counting efficiencies were exhibited, requiring optimization of the RBA protocol for the TopCount instrument. Precision, accuracy, and sensitivity [limit of detection = 0.2 microg saxitoxin (STX) equiv/100 g shellfish tissue] of the modified protocol were equivalent to those of the original protocol. The RBA robustness and adaptability were demonstrated by an interlaboratory study, in which STX concentrations in shellfish generated by the TopCount were consistent with MicroBeta-derived values. Comparison of STX reference standards obtained from the U.S. Food and Drug Administration and the National Research Council, Canada, showed no observable differences. This study confirms the RBA's value as a rapid, high throughput screen prior to testing by the conventional mouse bioassay (MBA) and its suitability for providing an early warning of increasing PSP toxicity when toxin levels are below the MBA limit of detection.

  20. An interlaboratory comparison of sizing and counting of subvisible particles mimicking protein aggregates.

    PubMed

    Ripple, Dean C; Montgomery, Christopher B; Hu, Zhishang

    2015-02-01

    Accurate counting and sizing of protein particles has been limited by discrepancies of counts obtained by different methods. To understand the bias and repeatability of techniques in common use in the biopharmaceutical community, the National Institute of Standards and Technology has conducted an interlaboratory comparison for sizing and counting subvisible particles from 1 to 25 μm. Twenty-three laboratories from industry, government, and academic institutions participated. The circulated samples consisted of a polydisperse suspension of abraded ethylene tetrafluoroethylene particles, which closely mimic the optical contrast and morphology of protein particles. For restricted data sets, agreement between data sets was reasonably good: relative standard deviations (RSDs) of approximately 25% for light obscuration counts with lower diameter limits from 1 to 5 μm, and approximately 30% for flow imaging with specified manufacturer and instrument setting. RSDs of the reported counts for unrestricted data sets were approximately 50% for both light obscuration and flow imaging. Differences between instrument manufacturers were not statistically significant for light obscuration but were significant for flow imaging. We also report a method for accounting for differences in the reported diameter for flow imaging and electrical sensing zone techniques; the method worked well for diameters greater than 15 μm. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  1. An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological

    PubMed Central

    Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA

    2016-01-01

    Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121

  2. An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: Observations, problems, solutions and lessons learned.

    PubMed

    Seed, Thomas M; Xiao, Shiyun; Manley, Nancy; Nikolich-Zugich, Janko; Pugh, Jason; Van den Brink, Marcel; Hirabayashi, Yoko; Yasutomo, Koji; Iwama, Atsushi; Koyasu, Shigeo; Shterev, Ivo; Sempowski, Gregory; Macchiarini, Francesca; Nakachi, Kei; Kunugi, Keith C; Hammer, Clifford G; Dewerd, Lawrence A

    2016-01-01

    An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.

  3. Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension

    NASA Astrophysics Data System (ADS)

    Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.

    2011-12-01

    The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.

  4. Certification by the Karl Fischer method of the water content in SRM 2890, Water Saturated 1-Octanol, and the analysis of associated interlaboratory bias in the measurement process.

    PubMed

    Margolis, S A; Levenson, M

    2000-05-01

    The calibration of Karl Fischer instruments and reagents and the compensation for instrumental bias are essential to the accurate measurement of trace levels of water in organic and inorganic chemicals. A stable, nonhygroscopic standard, Water Saturated Octanol, which is compatible with the Karl Fischer reagents, has been prepared. This material, Standard Reference Material (SRM) 2890, is homogeneous and is certified to contain 39.24 +/- 0.85 mg water/mL (expanded uncertainty) of solution (47.3 +/- 1.0 mg water/g solution, expanded uncertainty) at 21.5 degrees C. The solubility of water in -octanol has been shown to be nearly constant between 10 degrees C and 30 degrees C (i.e., within 1% of the value at 21.5 degrees C). The results of an interlaboratory comparison exercise illustrate the utility of SRM 2890 in assessing the accuracy and bias of Karl Fischer instruments and measurements.

  5. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species

    USGS Publications Warehouse

    Raimondo, Sandy; Lilavois, Crystal R.; Lee, Larisa; Augspurger, Tom; Wang, Ning; Ingersoll, Christopher G.; Bauer, Candice R.; Hammer, Edward J.; Barron, Mace G.

    2016-01-01

    We developed a toxicity database for unionid mussels to examine the extent of intra- and inter-laboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the two life stages; and the variation in sensitivity among commonly tested mussels (Lampsilis siliquoidea, Utterbackia imbecillis, Villosa iris), commonly tested cladocerans (Daphnia magna, Ceriodaphnia dubia) and fish (Oncorhynchus mykiss, Pimephales promelas, Lepomis macrochirus). The results of these analyses indicate intra-laboratory variability for median effect concentrations (EC50) averaged about 2 fold for both life stages, while inter-laboratory variability averaged 3.6 fold for juvenile mussels and 6.3 fold for glochidia. The EC50s for juveniles and glochidia were within a factor of 2 of each other for 50% of paired records across chemicals, with juveniles more sensitive than glochidia by more than 2 fold for 33% of the comparisons made between life stages. There was a high concurrence of the sensitivity of commonly tested L. siliquoidea, U. imbecillis, and V. iris to that of other mussels. However, this concurrence decreases as the taxonomic distance of the commonly tested cladocerans and fish to mussels increases. The compiled mussel database and determination of data variability will advance risk assessments by including more robust species sensitivity distributions, interspecies correlation estimates, and availability of taxon-specific empirically derived application factors for risk assessment.

  6. Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

    PubMed Central

    Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.

    2009-01-01

    Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range. PMID:19933777

  7. NanoRelease: Pilot interlaboratory comparison of a ...

    EPA Pesticide Factsheets

    A major use of multi-walled carbon nanotubes (MWCNTs) is as functional fillers embedded in a solid matrix, such as plastics or coatings. Weathering and abrasion of the solid matrix during use can lead to environmental releases of the MWCNTs. Here we focus on a protocol to identify and quantify the primary release induced by weathering, and assess reproducibility, transferability, and sensitivity towards different materials and uses. We prepared 132 specimens of two polymer-MWCNT composites containing the same grade of MWCNTs used in earlier OECD hazard assessments but without UV stabilizer. We report on a pilot inter-laboratory comparison (ILC) with four labs (two US and two EU) aging by UV and rain, then shipping for analysis. Two labs (one US and one EU) conducted the release sampling and analysis by Transmission Electron Microscopy (TEM), Inductively Coupled Plasma- Mass Spectrometry (ICP-MS), Ultraviolet–Visible Spectroscopy (UV–Vis), Analytical Ultracentrifugation (AUC), and Asymmetric Flow Field Flow Fractionation (AF4). We compare results between aging labs, between analysis labs and between materials. Surprisingly, we found quantitative agreement between analysis labs for TEM, ICP-MS, UV–Vis; low variation between aging labs by all methods; and consistent rankings of release between TEM, ICP-MS, UV–Vis, AUC. Significant disagreement was related primarily to differences in aging, but even these cases remained within a factor of two. Published in t

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Wade C.

    Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 andmore » S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.« less

  9. Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study

    NASA Astrophysics Data System (ADS)

    Motzkus, C.; Macé, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A.; Dirscherl, K.; Hodoroaba, V.-D.; Popov, I.; Popov, O.; Kuselman, I.; Takahata, K.; Ehara, K.; Ausset, P.; Maillé, M.; Michielsen, N.; Bondiguel, S.; Gensdarmes, F.; Morawska, L.; Johnson, G. R.; Faghihi, E. M.; Kim, C. S.; Kim, Y. H.; Chu, M. C.; Guardado, J. A.; Salas, A.; Capannelli, G.; Costa, C.; Bostrom, T.; Jämting, Å. K.; Lawn, M. A.; Adlem, L.; Vaslin-Reimann, S.

    2013-10-01

    Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—"Properties of Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 "Techniques for characterizing size distribution of airborne nanoparticles". Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2-46.6 nm and 80.2-89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.

  10. External quality assurance in nongynecologic cytology: The Australasian experience.

    PubMed

    Shield, Paul W; Frost, Felicity; Finnimore, Jo L; Wright, R Gordon; Cummings, Margaret C

    2017-05-01

    The Royal College of Pathologists of Australasia Cytopathology Quality Assurance Program has operated an external quality assurance program in nongynecologic cytopathology since 1993. Glass slide preparations of a wide range of nongynecologic cases were circulated to approximately 200 cytopathology laboratories in 16 countries. General nongynecologic cytology cases were manufactured from residual specimens after routine diagnosis. Fine-needle aspiration (FNA) cases were made by sampling fresh tissue and making direct specimens. The majority of cases consisted of both air-dried and fixed preparations. Results returned to laboratories included illustrated case discussions highlighting diagnostic features, key differential diagnoses, and useful adjunctive tests. The current study reviewed >22,000 results for 123 nongynecologic cases. Cases found to cause the most diagnostic difficulties included serous effusion cases with metastatic carcinoma in a dispersed pattern, well-differentiated carcinoma, and cellular reactive cases; urine specimens with sparse malignant cells; reactive pneumocytes in a bronchoalveolar lavage; breast FNA cases with papillary lesions; gestational specimens; and fibroadenoma. FNA specimens from the lung and thyroid, particularly papillary thyroid carcinoma, generally were well reported. The use of multiple preparations of the same specimen has allowed interlaboratory comparison, and the quality assurance program has played an educational role as well as informing the laboratory accreditation process. Cancer Cytopathol 2017;125:349-361. © 2017 American Cancer Society. © 2017 American Cancer Society.

  11. Development and validation of an OECD reproductive toxicity test guideline with the pond snail Lymnaea stagnalis (Mollusca, Gastropoda).

    PubMed

    Ducrot, Virginie; Askem, Clare; Azam, Didier; Brettschneider, Denise; Brown, Rebecca; Charles, Sandrine; Coke, Maïra; Collinet, Marc; Delignette-Muller, Marie-Laure; Forfait-Dubuc, Carole; Holbech, Henrik; Hutchinson, Thomas; Jach, Arne; Kinnberg, Karin L; Lacoste, Cédric; Le Page, Gareth; Matthiessen, Peter; Oehlmann, Jörg; Rice, Lynsey; Roberts, Edward; Ruppert, Katharina; Davis, Jessica Elphinstone; Veauvy, Clemence; Weltje, Lennart; Wortham, Ruth; Lagadic, Laurent

    2014-12-01

    The OECD test guideline development program has been extended in 2011 to establish a partial life-cycle protocol for assessing the reproductive toxicity of chemicals to several mollusk species, including the great pond snail Lymnaea stagnalis. In this paper, we summarize the standard draft protocol for a reproduction test with this species, and present inter-comparison results obtained in a 56-day prevalidation ring-test using this protocol. Seven European laboratories performed semi-static tests with cultured snails of the strain Renilys® exposed to nominal concentrations of cadmium chloride (from 53 to 608μgCdL(-1)). Cd concentrations in test solutions were analytically determined to confirm accuracy in the metal exposure concentrations in all laboratories. Physico-chemical and biological validity criteria (namely dissolved oxygen content >60% ASV, water temperature 20±1°C, control snail survival >80% and control snail fecundity >8 egg-masses per snail over the test period) were met in all laboratories which consistently demonstrated the reproductive toxicity of Cd in snails using the proposed draft protocol. Effect concentrations for fecundity after 56days were reproducible between laboratories (68

  12. Validation of Dissolution Testing with Biorelevant Media: An OrBiTo Study.

    PubMed

    Mann, James; Dressman, Jennifer; Rosenblatt, Karin; Ashworth, Lee; Muenster, Uwe; Frank, Kerstin; Hutchins, Paul; Williams, James; Klumpp, Lukas; Wielockx, Kristina; Berben, Philippe; Augustijns, Patrick; Holm, Rene; Hofmann, Michael; Patel, Sanjaykumar; Beato, Stefania; Ojala, Krista; Tomaszewska, Irena; Bruel, Jean-Luc; Butler, James

    2017-12-04

    Dissolution testing with biorelevant media has become widespread in the pharmaceutical industry as a means of better understanding how drugs and formulations behave in the gastrointestinal tract. Until now, however, there have been few attempts to gauge the reproducibility of results obtained with these methods. The aim of this study was to determine the interlaboratory reproducibility of biorelevant dissolution testing, using the paddle apparatus (USP 2). Thirteen industrial and three academic laboratories participated in this study. All laboratories were provided with standard protocols for running the tests: dissolution in FaSSGF to simulate release in the stomach, dissolution in a single intestinal medium, FaSSIF, to simulate release in the small intestine, and a "transfer" (two-stage) protocol to simulate the concentration profile when conditions are changed from the gastric to the intestinal environment. The test products chosen were commercially available ibuprofen tablets and zafirlukast tablets. The biorelevant dissolution tests showed a high degree of reproducibility among the participating laboratories, even though several different batches of the commercially available medium preparation powder were used. Likewise, results were almost identicalbetween the commercial biorelevant media and those produced in-house. Comparing results to previous ring studies, including those performed with USP calibrator tablets or commercially available pharmaceutical products in a single medium, the results for the biorelevant studies were highly reproducible on an interlaboratory basis. Interlaboratory reproducibility with the two-stage test was also acceptable, although the variability was somewhat greater than with the single medium tests. Biorelevant dissolution testing is highly reproducible among laboratories and can be relied upon for cross-laboratory comparisons.

  13. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    PubMed

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  14. Comparison of Different Matrices as Potential Quality Control Samples for Neurochemical Dementia Diagnostics.

    PubMed

    Lelental, Natalia; Brandner, Sebastian; Kofanova, Olga; Blennow, Kaj; Zetterberg, Henrik; Andreasson, Ulf; Engelborghs, Sebastiaan; Mroczko, Barbara; Gabryelewicz, Tomasz; Teunissen, Charlotte; Mollenhauer, Brit; Parnetti, Lucilla; Chiasserini, Davide; Molinuevo, Jose Luis; Perret-Liaudet, Armand; Verbeek, Marcel M; Andreasen, Niels; Brosseron, Frederic; Bahl, Justyna M C; Herukka, Sanna-Kaisa; Hausner, Lucrezia; Frölich, Lutz; Labonte, Anne; Poirier, Judes; Miller, Anne-Marie; Zilka, Norbert; Kovacech, Branislav; Urbani, Andrea; Suardi, Silvia; Oliveira, Catarina; Baldeiras, Ines; Dubois, Bruno; Rot, Uros; Lehmann, Sylvain; Skinningsrud, Anders; Betsou, Fay; Wiltfang, Jens; Gkatzima, Olymbia; Winblad, Bengt; Buchfelder, Michael; Kornhuber, Johannes; Lewczuk, Piotr

    2016-03-01

    Assay-vendor independent quality control (QC) samples for neurochemical dementia diagnostics (NDD) biomarkers are so far commercially unavailable. This requires that NDD laboratories prepare their own QC samples, for example by pooling leftover cerebrospinal fluid (CSF) samples. To prepare and test alternative matrices for QC samples that could facilitate intra- and inter-laboratory QC of the NDD biomarkers. Three matrices were validated in this study: (A) human pooled CSF, (B) Aβ peptides spiked into human prediluted plasma, and (C) Aβ peptides spiked into solution of bovine serum albumin in phosphate-buffered saline. All matrices were tested also after supplementation with an antibacterial agent (sodium azide). We analyzed short- and long-term stability of the biomarkers with ELISA and chemiluminescence (Fujirebio Europe, MSD, IBL International), and performed an inter-laboratory variability study. NDD biomarkers turned out to be stable in almost all samples stored at the tested conditions for up to 14 days as well as in samples stored deep-frozen (at - 80°C) for up to one year. Sodium azide did not influence biomarker stability. Inter-center variability of the samples sent at room temperature (pooled CSF, freeze-dried CSF, and four artificial matrices) was comparable to the results obtained on deep-frozen samples in other large-scale projects. Our results suggest that it is possible to replace self-made, CSF-based QC samples with large-scale volumes of QC materials prepared with artificial peptides and matrices. This would greatly facilitate intra- and inter-laboratory QC schedules for NDD measurements.

  15. Comparison of Fixed Point Realisations between Inmetro and PTB

    NASA Astrophysics Data System (ADS)

    Santiago, J. F. N.; Petkovic, S. G.; Teixeira, R. N.; Noatsch, U.; Thiele-Krivoj, B.

    2003-09-01

    An interlaboratory comparison in the temperature range between -190 °C and 420 °C was organised between the National Institute of Quality, Normalisation and Industrial Quality (Inmetro), Brazil, and the Physikalisch Technische Bundesanstalt (PTB), Germany. This comparison followed the same protocol as the EUROMET project 552 comparison and was carried out in the years 2001-2002. A standard platinum resistance thermometer (SPRT) of 25 Ω was calibrated at the temperature fixed points of Ar, Hg, the triple point of water (TWP), Ga, In, Sn and Zn, with at least three realisations of each fixed point at both institutes. The uncertainty evaluation is given by Inmetro and some differences in the calibration procedures or in the measuring instruments used are described. The agreement between the results of laboratories was not in all cases within the combined uncertainties. Results of other comparisons are presented, which give additional information on the equivalence of the realised temperature scales.

  16. The Case for Laboratory Developed Procedures

    PubMed Central

    Sabatini, Linda M.; Tsongalis, Gregory J.; Caliendo, Angela M.; Olsen, Randall J.; Ashwood, Edward R.; Bale, Sherri; Benirschke, Robert; Carlow, Dean; Funke, Birgit H.; Grody, Wayne W.; Hayden, Randall T.; Hegde, Madhuri; Lyon, Elaine; Pessin, Melissa; Press, Richard D.; Thomson, Richard B.

    2017-01-01

    An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories. PMID:28815200

  17. An interlaboratory study to test instrument performance of hydrogen dual-inlet isotope-ratio mass spectrometers

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, T.B.

    2001-01-01

    An interlaboratory comparison of forty isotope-ratio mass spectrometers of different ages from several vendors has been performed to test 2H/1H performance with hydrogen gases of three different isotopic compositions. The isotope-ratio results (unsufficiently corrected for H3+ contribution to the m/z = 3 collector, uncorrected for valve leakage in the change-over valves, etc.) expressed relative to one of these three gases covered a wide range of values: -630??? to -790??? for the second gas and -368??? to -462??? for the third gas. After normalizing the isotopic abundances of these test gases (linearly adjusting the ?? values so that the gases with the lowest and highest 2H content were identical for all laboratories), the standard deviation of the 40 measurements of the intermediate gas was a remarkably low 0.85???. It is concluded that the use of scaling factors is mandatory for providing accurate internationally comparable isotope-abundance values. Linear scaling for the isotope-ratio scales of gaseous hydrogen mass spectrometers is completely adequate. ?? Springer-Verlag 2001.

  18. Automating U-Pb IDTIMS data reduction and reporting: Cyberinfrastructure meets geochronology

    NASA Astrophysics Data System (ADS)

    Bowring, J. F.; McLean, N.; Walker, J. D.; Ash, J. M.

    2009-12-01

    We demonstrate the efficacy of an interdisciplinary effort between software engineers and geochemists to produce working cyberinfrastructure for geochronology. This collaboration between CIRDLES, EARTHTIME and EarthChem has produced the software programs Tripoli and U-Pb_Redux as the cyber-backbone for the ID-TIMS community. This initiative incorporates shared isotopic tracers, data-reduction algorithms and the archiving and retrieval of data and results. The resulting system facilitates detailed inter-laboratory comparison and a new generation of cooperative science. The resolving power of geochronological data in the earth sciences is dependent on the precision and accuracy of many isotopic measurements and corrections. Recent advances in U-Pb geochronology have reinvigorated its application to problems such as precise timescale calibration, processes of crustal evolution, and early solar system dynamics. This project provides a heretofore missing common data reduction protocol, thus promoting the interpretation of precise geochronology and enabling inter-laboratory comparison. U-Pb_Redux is an open-source software program that provides end-to-end support for the analysis of uranium-lead geochronological data. The system reduces raw mass spectrometer data to U-Pb dates, allows users to interpret ages from these data, and then provides for the seamless federation of the results, coming from many labs, into a community web-accessible database using standard and open techniques. This EarthChem GeoChron database depends also on keyed references to the SESAR sample database. U-Pb_Redux currently provides interactive concordia and weighted mean plots and uncertainty contribution visualizations; it produces publication-quality concordia and weighted mean plots and customizable data tables. This initiative has achieved the goal of standardizing the data elements of a complete reduction and analysis of uranium-lead data, which are expressed using extensible markup language schema definition (XSD) artifacts. U-Pb_Redux leverages the freeware program Tripoli, which imports raw mass spectrometer data files and supports interactive review and archiving of isotopic data. Tripoli facilitates the visualization of temporal trends and scatter during measurement, statistically rigorous filtering of data and supports oxide and fractionation corrections. The Cyber Infrastructure Research and Development Lab for the Earth Sciences (CIRDLES) collaboratively integrates domain-specific software engineering with the efforts EARTHTIME and Earthchem. The EARTHTIME initiative pursues consensus-based approaches to geochemical data reduction, and the EarthChem initiative pursues the creation of data repositories for all geochemical data. CIRDLES develops software and systems for geochronology. This collaboration benefits the earth sciences by enabling geochemists to focus on their specialties using robust software that produces reliable results. This collaboration benefits software engineering by providing research opportunities to improve process methodologies used in the design and implementation of domain-specific solutions.

  19. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE PAGES

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.; ...

    2015-07-30

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  20. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  1. Interlaboratory Collaborations in the Undergraduate Setting

    ERIC Educational Resources Information Center

    Megehee, Elise G.; Hyslop, Alison G.; Rosso, Richard J.

    2005-01-01

    A novel approach to cross-disciplinary and group learning, known as interlaboratory collaborations, was developed. The method mimics an industrial or research setting, fosters teamwork, and emphasizes the importance of good communication skills in the sciences.

  2. A multilaboratory peer assessment quality assurance program-based evaluation of anticardiolipin antibody, and beta2-glycoprotein I antibody testing.

    PubMed

    Favaloro, Emmanuel J; Wong, Richard C W; Silvestrini, Roger; McEvoy, Robert; Jovanovich, Susan; Roberts-Thomson, Peter

    2005-02-01

    We evaluated the performance of anticardiolipin (aCL) and beta2-glycoprotein I (beta2-GPI) antibody assays through a large external quality assurance program. Data from the 2002 cycle of the Royal College of Pathologists of Australasia Quality Assurance Program (RCPA QAP) were analyzed for variation in reported numerical values and semiquantitative results or interpretations according to method type or group and in conjunction with available clinical data. High interlaboratory variation in numerical results and notable method-based variation, combined with a general lack of consensus in semiquantitative reporting, continues to be observed. Numerical results from cross-laboratory testing of 12 serum samples (for immunoglobulin G [IgG]-aCL, IgM-aCL, and IgG-beta2-GPI) yielded interlaboratory coefficients of variation (CVs) that were higher than 50% in six of 12 (50%) specimens for IgG-aCL, and 12 of 12 (100%) specimens for IgM-aCL and IgG-beta2-GPI. Semiquantitative reporting also varied considerably, with total (100%) consensus occurring in only four of 36 (11%) occasions. General consensus (where > 90% of participating laboratories agreed that a given serum sample gave a result of either negative or positive) was only obtained on 13 of 36 (36%) occasions. Variation in results between different method types or groups were also present, resulting in potential biasing of the RCPA QAP-defined target results by the large number of laboratories using the dominant aCL assays. Finally, laboratory findings frequently did not agree with the available clinical information. In conclusion, in a large proportion of specimens from the 2002 RCPA QAP cycle, laboratories could not agree on whether a serum sample tested was aCL-positive or aCL-negative, or beta2-GPI-positive or beta2-GPI-negative. Despite prior attempts to improve the standardization of testing and reporting practices, laboratory testing for aCL and anti-beta2-GPI still demonstrates significant interlaboratory and intermethod variation, which needs to be taken into account for the clinical interpretation of test results, especially those from different laboratories.

  3. First Worldwide Proficiency Study on Variable-Number Tandem-Repeat Typing of Mycobacterium tuberculosis Complex Strains

    PubMed Central

    de Beer, Jessica L.; Kremer, Kristin; Ködmön, Csaba; Supply, Philip

    2012-01-01

    Although variable-number tandem-repeat (VNTR) typing has gained recognition as the new standard for the DNA fingerprinting of Mycobacterium tuberculosis complex (MTBC) isolates, external quality control programs have not yet been developed. Therefore, we organized the first multicenter proficiency study on 24-locus VNTR typing. Sets of 30 DNAs of MTBC strains, including 10 duplicate DNA samples, were distributed among 37 participating laboratories in 30 different countries worldwide. Twenty-four laboratories used an in-house-adapted method with fragment sizing by gel electrophoresis or an automated DNA analyzer, nine laboratories used a commercially available kit, and four laboratories used other methods. The intra- and interlaboratory reproducibilities of VNTR typing varied from 0% to 100%, with averages of 72% and 60%, respectively. Twenty of the 37 laboratories failed to amplify particular VNTR loci; if these missing results were ignored, the number of laboratories with 100% interlaboratory reproducibility increased from 1 to 5. The average interlaboratory reproducibility of VNTR typing using a commercial kit was better (88%) than that of in-house-adapted methods using a DNA analyzer (70%) or gel electrophoresis (50%). Eleven laboratories using in-house-adapted manual typing or automated typing scored inter- and intralaboratory reproducibilities of 80% or higher, which suggests that these approaches can be used in a reliable way. In conclusion, this first multicenter study has documented the worldwide quality of VNTR typing of MTBC strains and highlights the importance of international quality control to improve genotyping in the future. PMID:22170917

  4. Lupus anticoagulants: first French interlaboratory Etalonorme survey.

    PubMed

    Roussi, J; Roisin, J P; Goguel, A

    1996-06-01

    In 1994, the, French National Quality Control Group for Hematology, Etalonorme, conducted a large-scale interlaboratory survey concerning the detection of lupus anticoagulants (LA) involving all the 4,500 French laboratories. Each laboratory received the same batch of a lyophilized citrated plasma (94B3) prepared from a patient with LA that had been confirmed by all the techniques used in the intralaboratory study. In the interlaboratory survey, the screening test was activated partial thromboplastin time (APTT); mean APTT calculated from the results reported by 4,029 labs was prolonged (clotting ratio = 1.44) with a large dispersion (coefficients of variation = 18.8%). APTT of the mixture 94B3 + normal plasma were performed by 2,698 laboratories. No correction of APTT was obtained (R = 1.36, Rosner index = 24) with a wide variation between reagents (17 < Rosner index < 39). Only 15% of the participants performed confirmatory tests; dilute tissue thromboplastin inhibition test (TTI) performed by 509 laboratories gave 75% positive results. Tests with an increased amount of phospholipids (Staclot LA and Staclot PNP from Diagnostica Stago), used by 116 and 72 laboratories, gave 88% and 61% positive results, respectively. A total of 1,862 laboratories made the diagnosis of LA. The majority of those who failed in diagnosing LA used an APTT reagent largely used in France, containing kaolin. This survey allowed Etalonorme to inform French biologists and draft an educational program for the biologic detection of LA and the identification of its mechanism of action.

  5. Evaluating diagnostic tests for bovine tuberculosis in the southern part of Germany: A latent class analysis

    PubMed Central

    Knubben-Schweizer, Gabriela; Döpfer, Dörte; Groll, Andreas; Hafner-Marx, Angela; Hörmansdorfer, Stefan; Sauter-Louis, Carola; Straubinger, Reinhard K.; Zimmermann, Pia; Hartnack, Sonja

    2017-01-01

    Germany has been officially free of bovine tuberculosis since 1996. However, in the last years there has been an increase of bovine tuberculosis cases, particularly in the southern part of Germany, in the Allgäu region. As a consequence a one-time tuberculosis surveillance program was revisited with different premortal and postmortal tests. The aim of this paper was to estimate diagnostic sensitivities and specificities of the different tests used within this surveillance program. In the absence of a perfect test with 100% sensitivity and 100% specificity, thus in the absence of a gold standard, a Bayesian latent class approach with two different datasets was performed. The first dataset included 389 animals, tested with single intra-dermal comparative cervical tuberculin (SICCT) test, PCR and pathology; the second dataset contained 175 animals, tested with single intra-dermal cervical tuberculin (SICT) test, Bovigam® assay, pathology and culture. Two-way conditional dependencies were considered within the models. Additionally, inter-laboratory agreement (five officially approved laboratories) of the Bovigam® assay was assessed with Cohen's kappa test (21 blood samples). The results are given in posterior means and 95% credibility intervals. The specificities of the SICT test, SICCT test, PCR and pathology ranged between 75.8% [68.8–82.2%] and 99.0% [96.8–100%]. The Bovigam® assay stood out with a very low specificity (6.9% [3.6–11.1%]), though it had the highest sensitivity (95.7% [91.3–99.2%]). The sensitivities of the SICCT test, PCR, SICT test, pathology and culture varied from 57.8% [48.0–67.6%] to 88.9% [65.5–99.7%]. The prevalences were 19.8% [14.6–26.5%] (three-test dataset) and 7.7% [4.2–12.3%] (four-test dataset). Among all pairwise comparisons the highest agreement was 0.62 [0.15–1]). In conclusion, the specificity of the Bovigam® assay and the inter-laboratory agreement were lower than expected. PMID:28640908

  6. An interlaboratory comparison study on the measurement of elements in PM10

    NASA Astrophysics Data System (ADS)

    Yatkin, Sinan; Belis, Claudio A.; Gerboles, Michel; Calzolai, Giulia; Lucarelli, Franco; Cavalli, Fabrizia; Trzepla, Krystyna

    2016-01-01

    An inter-laboratory comparison study was conducted to measure elemental loadings on PM10 samples, collected in Ispra, a regional background/rural site in Italy, using three different XRF (X-ray Fluorescence) methods, namely Epsilon 5 by linear calibration, Quant'X by the standardless analysis, and PIXE (Particle Induced X-ray Emission) with linear calibration. A subset of samples was also analyzed by ICP-MS (Inductively Coupled Plasma-Mass Spectrometry). Several metrics including method detection limits (MDLs), precision, bias from a NIST standard reference material (SRM 2783) quoted values, relative absolute difference, orthogonal regression and the ratio of the absolute difference between the methods to claimed uncertainty were used to compare the laboratories. The MDLs were found to be comparable for many elements. Precision estimates were less than 10% for the majority of the elements. Absolute biases from SRM 2783 remained less than 20% for the majority of certified elements. The regression results of PM10 samples showed that the three XRF laboratories measured very similar mass loadings for S, K, Ti, Mn, Fe, Cu, Br, Sr and Pb with slopes within 20% of unity. The ICP-MS results confirmed the agreement and discrepancies between XRF laboratories for Al, K, Ca, Ti, V, Cu, Sr and Pb. The ICP-MS results are inconsistent with the XRF laboratories for Fe and Zn. The absolute differences between the XRF laboratories generally remained within their claimed uncertainties, showing a pattern generally consistent with the orthogonal regression results.

  7. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. AN INTERLABORATORY STUDY OF PERFLUORINATED ALKYL COMPOUND LEVELS IN HUMAN PLASMA

    EPA Science Inventory

    The present study was designed to investigate intra- and interlaboratory variability in results from six laboratories experienced in the analysis of perfluorinated alkyl compounds in blood matrices and that use stringent procedures to control and assure accuracy and precision. Ea...

  9. An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance Program.

    PubMed

    Bedner, Mary; Lippa, Katrice A; Tai, Susan S-C

    2013-11-15

    The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. © 2013.

  10. Interlaboratory Validation of the Leaching Environmental Assessment Framework (LEAF) Method 1313 and Method 1316

    EPA Science Inventory

    This document summarizes the results of an interlaboratory study conducted to generate precision estimates for two parallel batch leaching methods which are part of the Leaching Environmental Assessment Framework (LEAF). These methods are: (1) Method 1313: Liquid-Solid Partition...

  11. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  12. Comparison of δ18O measurements in nitrate by different combustion techniques

    USGS Publications Warehouse

    Revesz, Kinga; Böhlke, John Karl

    2002-01-01

    Three different KNO3 salts with δ18O values ranging from about −31 to +54‰ relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with δ18O values in the midpoint of the δ18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25‰). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the δ18O scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with δ18O values far from that of atmospheric O2, to improve interlaboratory comparability.

  13. External quality-assurance project report for the National Atmospheric Deposition Program/National Trends Network and Mercury Deposition Network, 2009-2010

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn; Rhodes, Mark F.; Chesney, Tanya A.

    2014-01-01

    The U.S. Geological Survey operated six distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program/National Trends Network (NTN) and Mercury Deposition Network (MDN) during 2009–2010. The field-audit program assessed the effects of onsite exposure, sample handling, and shipping on the chemistry of NTN samples; a system-blank program assessed the same effects for MDN. Two interlaboratory-comparison programs assessed the bias and variability of the chemical analysis data from the Central Analytical Laboratory (CAL) and Mercury (Hg) Analytical Laboratory (HAL). The blind-audit program was also implemented for the MDN to evaluate analytical bias in total Hg concentration data produced by the HAL. The co-located-sampler program was used to identify and quantify potential shifts in NADP data resulting from replacement of original network instrumentation with new electronic recording rain gages (E-gages) and precipitation collectors that use optical sensors. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends of chemical constituents in wet deposition across the United States. Results also suggest that retrofit of the NADP networks with the new precipitation collectors could cause –8 to +14 percent shifts in NADP annual precipitation-weighted mean concentrations and total deposition values for ammonium, nitrate, sulfate, and hydrogen ion, and larger shifts (+13 to +74 percent) for calcium, magnesium, sodium, potassium, and chloride. The prototype N-CON Systems bucket collector is more efficient in the catch of precipitation in winter than Aerochem Metrics Model 301 collector, especially for light snowfall.

  14. U.S. Geological Survey external quality-assurance project report for the National Atmospheric Deposition Program / National Trends Network and Mercury Deposition Network, 2011-2012

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn

    2014-01-01

    The U.S. Geological Survey operated six distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program (NADP) / National Trends Network (NTN) and Mercury Deposition Network (MDN) during 2011–2012. The field-audit program assessed the effects of onsite exposure, sample handling, and shipping on the chemistry of NTN samples; a system-blank program assessed the same effects for MDN. Two interlaboratory-comparison programs assessed the bias and variability of the chemical analysis data from the Central Analytical Laboratory and Mercury Analytical Laboratory (HAL). A blind-audit program was implemented for the MDN during 2011 to evaluate analytical bias in HAL total mercury concentration data. The co-located–sampler program was used to identify and quantify potential shifts in NADP data resulting from the replacement of original network instrumentation with new electronic recording rain gages and precipitation collectors that use optical precipitation sensors. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends of chemical constituents in wet deposition across the United States. Co-located rain gage results indicate -3.7 to +6.5 percent bias in NADP precipitation-depth measurements. Co-located collector results suggest that the retrofit of the NADP networks with the new precipitation collectors could cause +10 to +36 percent shifts in NADP annual deposition values for ammonium, nitrate, and sulfate; -7.5 to +41 percent shifts for hydrogen-ion deposition; and larger shifts (-51 to +52 percent) for calcium, magnesium, sodium, potassium, and chloride. The prototype N-CON Systems bucket collector typically catches more precipitation than the NADP-approved Aerochem Metrics Model 301 collector.

  15. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse.

    PubMed

    Martínez-Granados, Luis; Serrano, María; González-Utor, Antonio; Ortíz, Nereyda; Badajoz, Vicente; Olaya, Enrique; Prados, Nicolás; Boada, Montse; Castilla, Jose A

    2017-01-01

    The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost-perfect inter-laboratory agreement among conventional morphological assessment (CMA), EmbryoScope™ and Primo Vision™, except for false divisions, vacuoles and asymmetry (users of all methods) and multinucleation (users of Primo Vision™), where the degree of agreement was lower. The inter-laboratory agreement on embryo classification according to the ASEBIR criteria was moderate-substantial (Gwet 0.41-0.80) for the laboratories using CMA and EmbryoScope™, and fair-moderate (Gwet 0.21-0.60) for those using Primo Vision™. The inter-laboratory agreement for clinical decision was moderate (Gwet 0.41-0.60) on day 5 for CMA users and almost perfect (Gwet 0.81-1) for time-lapse users. In conclusion, time-lapse technology does not improve inter-laboratory agreement on embryo classification or the analysis of each morphological variable. Moreover, depending on the time-lapse platform used, inter-laboratory agreement may be lower than that obtained by CMA. However, inter-laboratory agreement on clinical decisions is improved with the use of time lapse, regardless of the platform used.

  16. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse

    PubMed Central

    Serrano, María; González-Utor, Antonio; Ortíz, Nereyda; Badajoz, Vicente; Olaya, Enrique; Prados, Nicolás; Boada, Montse; Castilla, Jose A.

    2017-01-01

    The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost-perfect inter-laboratory agreement among conventional morphological assessment (CMA), EmbryoScope™ and Primo Vision™, except for false divisions, vacuoles and asymmetry (users of all methods) and multinucleation (users of Primo Vision™), where the degree of agreement was lower. The inter-laboratory agreement on embryo classification according to the ASEBIR criteria was moderate-substantial (Gwet 0.41–0.80) for the laboratories using CMA and EmbryoScope™, and fair-moderate (Gwet 0.21–0.60) for those using Primo Vision™. The inter-laboratory agreement for clinical decision was moderate (Gwet 0.41–0.60) on day 5 for CMA users and almost perfect (Gwet 0.81–1) for time-lapse users. In conclusion, time-lapse technology does not improve inter-laboratory agreement on embryo classification or the analysis of each morphological variable. Moreover, depending on the time-lapse platform used, inter-laboratory agreement may be lower than that obtained by CMA. However, inter-laboratory agreement on clinical decisions is improved with the use of time lapse, regardless of the platform used. PMID:28841654

  17. Standardization of reflectance measurements in dispersed organic matter: results of an exercise to improve interlaboratory agreement

    USGS Publications Warehouse

    Hackley, Paul C.; Araujo, Carla Viviane; Borrego, Angeles G.; Bouzinos, Antonis; Cardott, Brian; Cook, Alan C.; Eble, Cortland; Flores, Deolinda; Gentzis, Thomas; Gonçalves, Paula Alexandra; Filho, João Graciano Mendonça; Hámor-Vidó, Mária; Jelonek, Iwona; Kommeren, Kees; Knowles, Wayne; Kus, Jolanta; Mastalerz, Maria; Menezes, Taíssa Rêgo; Newman, Jane; Pawlewicz, Mark; Pickel, Walter; Potter, Judith; Ranasinghe, Paddy; Read, Harold; Reyes, Julito; Rodriguez, Genaro De La Rosa; de Souza, Igor Viegas Alves Fernandes; Suarez-Ruiz, Isabel; Sýkorová, Ivana; Valentine, Brett J.

    2015-01-01

    Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the D7708 measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (0.31-1.53% Ro), from organic-lean to organic-rich (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability limits (maximum difference between valid repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility limits (maximum difference between valid results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility limits degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping the other components. Discussion among participants suggested this problem could not be easily corrected via kerogen concentration or solvent extraction and is related to operator training and background. No statistical difference in mean reflectance was identified between participants reporting bitumen reflectance vs. vitrinite reflectance vs. a mixture of bitumen and vitrinite reflectance values, suggesting empirical conversion schemes should be treated with caution. Analysis of reproducibility limits obtained during this exercise in comparison to reproducibility limits from historical interlaboratory exercises suggests use of a common methodology (D7708) improves interlaboratory precision. Future work will investigate opportunities to improve reproducibility in high maturity, organic-lean shale varieties.

  18. External quality assessment programs in the context of ISO 15189 accreditation.

    PubMed

    Sciacovelli, Laura; Secchiero, Sandra; Padoan, Andrea; Plebani, Mario

    2018-05-23

    Effective management of clinical laboratories participating in external quality assessment schemes (EQAS) is of fundamental importance in ensuring reliable analytical results. The International Standard ISO 15189:2012 requires participation in interlaboratory comparison [e.g. external quality assessment (EQA)] for all tests provided by an individual laboratory. If EQAS is not commercially available, alternative approaches should be identified, although clinical laboratories may find it challenging to choose the EQAS that comply with the international standards and approved guidelines. Great competence is therefore required, as well as knowledge of the characteristics and key elements affecting the reliability of an EQAS, and the analytical quality specifications stated in approved documents. Another skill of fundamental importance is the ability to identify an alternative approach when the available EQAS are inadequate or missing. Yet the choice of the right EQA program alone does not guarantee its effectiveness. In fact, the fundamental steps of analysis of the information provided in EQA reports and the ability to identify improvement actions to be undertaken call for the involvement of all laboratory staff playing a role in the specific activity. The aim of this paper was to describe the critical aspects that EQA providers and laboratory professionals should control in order to guarantee effective EQAS management and compliance with ISO 15189 accreditation requirements.

  19. Pilot Inter-Laboratory Studies for Evaluating Weathering-Induced Release of Carbon Nanotubes from Solid Matrices

    EPA Science Inventory

    Nanomaterials are increasingly being used in polymer composites to enhance the properties of these materials. Here we present results of a pilot inter-laboratory study to simulate the effects of weathering on the potential release of multiwalled carbon nanotubes (MWCNT) from thei...

  20. Interlaboratory Validation of the Leaching Environmental Assessment Framework (LEAF) Method 1314 and Method 1315

    EPA Science Inventory

    This report summarizes the results of an interlaboratory study conducted to generate precision estimates for two leaching methods under review by the U.S. EPA’s OSWER for inclusion into the EPA’s SW-846: Method 1314: Liquid-Solid Partitioning as a Function of Liquid...

  1. The International Interlaboratory Quality Control Program for Measurement of Antiretroviral Drugs in Plasma: a global proficiency testing program.

    PubMed

    Burger, David; Teulen, Marga; Eerland, Jaco; Harteveld, Anneke; Aarnoutse, Rob; Touw, Daan

    2011-04-01

    The International Interlaboratory Quality Control Program for Measurement of Antiretroviral Drugs in Plasma was initiated in 1999 by Radboud University Nijmegen Medical Center, The Netherlands, and continued later on in collaboration with the Dutch Association for Quality Assessment in Therapeutic Drug Monitoring and Clinical Toxicology (www.kkgt.nl). The aim of this analysis was to evaluate the first 10 years of the Program and to determine variables associated with reporting of less accurate results. Two rounds are organized annually in which blind samples are shipped to participants containing a low, medium, or high concentration of each antiretroviral drug. Any reported result that deviates more than 20% from the spiked concentration is defined as inaccurate. By the end of 2009, the number of laboratories participating in the Program had increased to 56; 44 (79%) are located in Europe. A total of 12,798 test results was available for analysis, of which 2104 (16.4%) were reported as inaccurate. Performance was best for samples containing nevirapine (mean of inadequate scores per round: 11.1%) and lopinavir (11.9%) and worst for indinavir (18.7%), atazanavir (18.9%), saquinavir (19.6%), and nelfinavir (21.3%). High and medium concentrations were less frequently reported as inaccurate than low concentrations: 13.5%, 13.0%, and 22.4%, respectively. Although the overall performance of the laboratories varied per year, a trend was visible for improvement over time with 19.9% of the results being inaccurate in 2002 (n = 20 laboratories) to 15.7% in 2009 (n = 56 laboratories). The Program provides a proficiency testing program in which laboratories are alerted to potential analytical errors while performing therapeutic drug monitoring in HIV-infected patients. Laboratories should put more effort in adequately analyzing concentrations of antiretroviral drugs with low minimum effective concentrations.

  2. The breaking load method - Results and statistical modification from the ASTM interlaboratory test program

    NASA Technical Reports Server (NTRS)

    Colvin, E. L.; Emptage, M. R.

    1992-01-01

    The breaking load test provides quantitative stress corrosion cracking data by determining the residual strength of tension specimens that have been exposed to corrosive environments. Eight laboratories have participated in a cooperative test program under the auspices of ASTM Committee G-1 to evaluate the new test method. All eight laboratories were able to distinguish between three tempers of aluminum alloy 7075. The statistical analysis procedures that were used in the test program do not work well in all situations. An alternative procedure using Box-Cox transformations shows a great deal of promise. An ASTM standard method has been drafted which incorporates the Box-Cox procedure.

  3. Quality assurance and quality control for thermal/optical analysis of aerosol samples for organic and elemental carbon.

    PubMed

    Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K

    2011-12-01

    Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.

  4. Quality-assurance results for field pH and specific-conductance measurements, and for laboratory analysis, National Atmospheric Deposition Program and National Trends Network; January 1980-September 1984

    USGS Publications Warehouse

    Schroder, L.J.; Brooks, M.H.; Malo, B.A.; Willoughby, T.C.

    1986-01-01

    Five intersite comparison studies for the field determination of pH and specific conductance, using simulated-precipitation samples, were conducted by the U.S.G.S. for the National Atmospheric Deposition Program and National Trends Network. These comparisons were performed to estimate the precision of pH and specific conductance determinations made by sampling-site operators. Simulated-precipitation samples were prepared from nitric acid and deionized water. The estimated standard deviation for site-operator determination of pH was 0.25 for pH values ranging from 3.79 to 4.64; the estimated standard deviation for specific conductance was 4.6 microsiemens/cm at 25 C for specific-conductance values ranging from 10.4 to 59.0 microsiemens/cm at 25 C. Performance-audit samples with known analyte concentrations were prepared by the U.S.G.S.and distributed to the National Atmospheric Deposition Program 's Central Analytical Laboratory. The differences between the National Atmospheric Deposition Program and national Trends Network-reported analyte concentrations and known analyte concentrations were calculated, and the bias and precision were determined. For 1983, concentrations of calcium, magnesium, sodium, and chloride were biased at the 99% confidence limit; concentrations of potassium and sulfate were unbiased at the 99% confidence limit. Four analytical laboratories routinely analyzing precipitation were evaluated in their analysis of identical natural- and simulated precipitation samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple-range test on data produced by these laboratories, from the analysis of identical simulated-precipitation samples. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Interlaboratory comparability results may be used to normalize natural-precipitation chemistry data obtained from two or more of these laboratories. (Author 's abstract)

  5. INTERLABORATORY STUDY OF A THERMOSPRAY-LIQUID CHROMATOGRAPHIC/MASS SPECTROMETRIC METHOD FOR SELECTED N-METHYL CARBAMATES, N-METHYL CARBAMOYLOXIMES, AND SUBSTITUTED UREA PESTICIDES

    EPA Science Inventory

    A thermospray-liquid chromatographic/mass spectrometric (TS-LC/MS) method was evaluated in an interlaboratory study for determining 3 N-methyl carbamates (bendiocarb, carbaryl, and carbofuran), 3-N-methyl carbamoyloximes (aldicarb, methomyl, and oxamyl), 2 substituted urea pestic...

  6. Precision of the upgraded cottonscan instrument for measuring the average fiber linear density (fineness) of cotton lint samples

    USDA-ARS?s Scientific Manuscript database

    An inter-laboratory trial was conducted to validate the operation of the CottonscanTM technology as useful technique for determining the average fiber linear density of cotton. A significant inter-laboratory trial was completed and confirmed that the technology is quite acceptable. For fibers fin...

  7. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species

    EPA Science Inventory

    The authors developed a toxicity database for unionid mussels to examine the extent of intra- and interlaboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the 2 life stages; and the variation in se...

  8. Determination of total dietary fiber in selected foods containing resistant maltodextrin by a simplified enzymatic-gravimetric method and liquid chromatography: interlaboratory study in China.

    PubMed

    Fu, Boqiang; Wang, Jing; Roturier, Jean Michel; Tang, Zhiyu; Li, Huan; Wei, Guangyan

    2008-01-01

    An interlaboratory study was conducted in China to validate the modified AOAC Official Method 2001.03 for the determination of total dietary fiber (TDF) in foods containing resistant maltodextrin (RMD), which will be adopted as the National Standard Method of China. The kind of buffer solution, the volume of filtrate evaporation, the volume of eluent for desalting and residual solution after evaporation, etc. were modified, which had been proved to have acceptable accuracy and precision in the routine assay. TDF contents in 3 representative foods and 2 kinds of RMD ingredient (i.e., NUTRIOSE 06 and NUTRIOSE 10) were measured using the modified method in 6 eligible laboratories representing commercial, industrial, and governmental laboratories in China. The results of the interlaboratory study indicated that the intralaboratory repeatability, interlaboratory reproducibility, and precision of the modified method are adequate for reliable analysis of TDF in food containing RMD, as well as resistant dextrin. Compared to AOAC Official Method 2001.03, the modified method is time- and cost-saving.

  9. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species - SETAC Abstract

    EPA Science Inventory

    We developed a toxicity database for unionid mussels to examine the extent of intra- and inter-laboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the two life stages; and the variation in sensitiv...

  10. Establishment and validation of analytical reference panels for the standardization of quantitative BCR-ABL1 measurements on the international scale.

    PubMed

    White, Helen E; Hedges, John; Bendit, Israel; Branford, Susan; Colomer, Dolors; Hochhaus, Andreas; Hughes, Timothy; Kamel-Reid, Suzanne; Kim, Dong-Wook; Modur, Vijay; Müller, Martin C; Pagnano, Katia B; Pane, Fabrizio; Radich, Jerry; Cross, Nicholas C P; Labourier, Emmanuel

    2013-06-01

    Current guidelines for managing Philadelphia-positive chronic myeloid leukemia include monitoring the expression of the BCR-ABL1 (breakpoint cluster region/c-abl oncogene 1, non-receptor tyrosine kinase) fusion gene by quantitative reverse-transcription PCR (RT-qPCR). Our goal was to establish and validate reference panels to mitigate the interlaboratory imprecision of quantitative BCR-ABL1 measurements and to facilitate global standardization on the international scale (IS). Four-level secondary reference panels were manufactured under controlled and validated processes with synthetic Armored RNA Quant molecules (Asuragen) calibrated to reference standards from the WHO and the NIST. Performance was evaluated in IS reference laboratories and with non-IS-standardized RT-qPCR methods. For most methods, percent ratios for BCR-ABL1 e13a2 and e14a2 relative to ABL1 or BCR were robust at 4 different levels and linear over 3 logarithms, from 10% to 0.01% on the IS. The intraassay and interassay imprecision was <2-fold overall. Performance was stable across 3 consecutive lots, in multiple laboratories, and over a period of 18 months to date. International field trials demonstrated the commutability of the reagents and their accurate alignment to the IS within the intra- and interlaboratory imprecision of IS-standardized methods. The synthetic calibrator panels are robust, reproducibly manufactured, analytically calibrated to the WHO primary standards, and compatible with most BCR-ABL1 RT-qPCR assay designs. The broad availability of secondary reference reagents will further facilitate interlaboratory comparative studies and independent quality assessment programs, which are of paramount importance for worldwide standardization of BCR-ABL1 monitoring results and the optimization of current and new therapeutic approaches for chronic myeloid leukemia. © 2013 American Association for Clinical Chemistry.

  11. Re-collection of Fish Canyon Tuff for fission-track standardization

    USGS Publications Warehouse

    Naeser, C.W.; Cebula, G.T.

    1984-01-01

    The PURPOSE of this note is to announce the availability of apatite and zircon from a third collection of the Oligocene Fish Canyon Tuff (FC-3). Apatite and zircon separated from the Fish Canyon Tuff have prove to be a useful standard for fission-track dating, both for interlaboratory comparisons and for checking procedures within a laboratory. In May 1981, about 540 kg of Fish Canyon Tuff were collected for mineral separation. Approximately 7. 5 g of apatite, 6. 5 g of zircon, and 89 g of sphene were recovered from this collection. This new material is now ready for distribution.

  12. An Assessment of 25-Hydroxyvitamin D Measurements in Comparability Studies Conducted by the Vitamin D Metabolites Quality Assurance Program

    PubMed Central

    Bedner, Mary; Lippa, Katrice A.; Tai, Susan S.-C.

    2013-01-01

    Background The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. Methods Study samples were comprised of human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. Results For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3), the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Conclusions Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. PMID:23978484

  13. An inter-laboratory comparison study on transfer, persistence and recovery of DNA from cable ties.

    PubMed

    Steensma, Kristy; Ansell, Ricky; Clarisse, Lindy; Connolly, Edward; Kloosterman, Ate D; McKenna, Louise G; van Oorschot, Roland A H; Szkuta, Bianca; Kokshoorn, Bas

    2017-11-01

    To address questions on the activity that led to the deposition of biological traces in a particular case, general information on the probabilities of transfer, persistence and recovery of cellular material in relevant scenarios is necessary. These figures may be derived from experimental data described in forensic literature when conditions relevant to the case were included. The experimental methodology regarding sampling, DNA extraction, DNA typing and profile interpretation that were used to generate these published data may differ from those applied in the case and thus the applicability of the literature data may be questioned. To assess the level of variability that different laboratories obtain when similar exhibits are analysed, we performed an inter-laboratory study between four partner laboratories. Five sets of 20 cable ties bound by different volunteers were distributed to the participating laboratories and sampled and processed according to the in-house protocols. Differences were found for the amount of retrieved DNA, as well as for the reportability and composition of the DNA profiles. These differences also resulted in different probabilities of transfer, persistence and recovery for each laboratory. Nevertheless, when applied to a case example, these differences resulted in similar assignments of weight of evidence given activity-level propositions. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Inter-laboratory quality control for hormone-dependent gene expression in human breast tumors using real-time reverse transcription-polymerase chain reaction.

    PubMed

    de Cremoux, P; Bieche, I; Tran-Perennou, C; Vignaud, S; Boudou, E; Asselain, B; Lidereau, R; Magdelénat, H; Becette, V; Sigal-Zafrani, B; Spyratos, F

    2004-09-01

    Quantitative reverse transcription-polymerase chain reaction (RT-PCR) used to detect minor changes in specific mRNA concentrations may be associated with poor reproducibility. Stringent quality control is therefore essential at each step of the protocol, including the PCR procedure. We performed inter-laboratory quality control of quantitative PCR between two independent laboratories, using in-house RT-PCR assays on a series of hormone-related target genes in a retrospective consecutive series of 79 breast tumors. Total RNA was reverse transcribed in a single center. Calibration curves were performed for five target genes (estrogen receptor (ER)alpha, ERbeta, progesterone receptor (PR), CYP19 (aromatase) and Ki 67) and for two reference genes (human acidic ribosomal phosphoprotein PO (RPLPO) and TATA box-binding protein (TBP)). Amplification efficiencies of the calibrator were determined for each run and used to calculate mRNA expression. Correlation coefficients were evaluated for each target and each reference gene. A good correlation was observed for all target and reference genes in both centers using their own protocols and kits (P < 0.0001). The correlation coefficients ranged from 0.90 to 0.98 for the various target genes in the two centers. A good correlation was observed between the level of expression of the ERalpha and the PR transcripts (P < 0.001). A weak inverse correlation was observed in both centers between ERalpha and ERbeta levels, but only when TBP was the reference gene. No other correlation was observed with other parameters. Real-time PCR assays allow convenient quantification of target mRNA transcripts and quantification of target-derived nucleic acids in clinical specimens. This study addresses the importance of inter-laboratory quality controls for the use of a panel of real-time PCR assays devoted to clinical samples and protocols and to ensure their appropriate accuracy. This can also facilitate exchanges and multicenter comparison of data.

  15. Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

    PubMed

    Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J

    2003-08-22

    Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

  16. Second NBL measurement evaluation program meeting: A summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spaletto, M.I.; Clapper, M.; Tolbert, M.E.M.

    New Brunswick Laboratory (NBL), the US government`s nuclear materials measurements and reference materials laboratory, administers interlaboratory measurement evaluation programs to evaluate the quality and adequacy of safeguards measurements. The NBL Measurement Evaluation Program covers several types of safeguards analytical measurements. The Safeguards Measurement Evaluation (SME) program distributes test materials destructive measurements of uranium for both elemental concentration and isotopic abundances, and of plutonium for isotopic abundances. The Calorimetry Exchange (CalEx) Program tests the quality of nondestructive measurements of plutonium isotopic abundances by gamma spectroscopy and plutonium concentration by calorimetry. In May 1997, more than 30 representatives from the Department ofmore » Energy (DOE), its contractor laboratories, and Nuclear Regulatory Commission licensees met at NBL in Argonne, Illinois, for the annual meeting of the Measurement Evaluation Program. The summary which follows details key points that were discussed or presented at the meeting.« less

  17. Measuring the uncertainties of discharge measurements: interlaboratory experiments in hydrometry

    NASA Astrophysics Data System (ADS)

    Le Coz, Jérôme; Blanquart, Bertrand; Pobanz, Karine; Dramais, Guillaume; Pierrefeu, Gilles; Hauet, Alexandre; Despax, Aurélien

    2015-04-01

    Quantifying the uncertainty of streamflow data is key for hydrological sciences. The conventional uncertainty analysis based on error propagation techniques is restricted by the absence of traceable discharge standards and by the weight of difficult-to-predict errors related to the operator, procedure and measurement environment. Field interlaboratory experiments recently emerged as an efficient, standardized method to 'measure' the uncertainties of a given streamgauging technique in given measurement conditions. Both uncertainty approaches are compatible and should be developed jointly in the field of hydrometry. In the recent years, several interlaboratory experiments have been reported by different hydrological services. They involved different streamgauging techniques, including acoustic profilers (ADCP), current-meters and handheld radars (SVR). Uncertainty analysis was not always their primary goal: most often, testing the proficiency and homogeneity of instruments, makes and models, procedures and operators was the original motivation. When interlaboratory experiments are processed for uncertainty analysis, once outliers have been discarded all participants are assumed to be equally skilled and to apply the same streamgauging technique in equivalent conditions. A universal requirement is that all participants simultaneously measure the same discharge, which shall be kept constant within negligible variations. To our best knowledge, we were the first to apply the interlaboratory method for computing the uncertainties of streamgauging techniques, according to the authoritative international documents (ISO standards). Several specific issues arise due to the measurements conditions in outdoor canals and rivers. The main limitation is that the best available river discharge references are usually too uncertain to quantify the bias of the streamgauging technique, i.e. the systematic errors that are common to all participants in the experiment. A reference or a sensitivity analysis to the fixed parameters of the streamgauging technique remain very useful for estimating the uncertainty related to the (non quantified) bias correction. In the absence of a reference, the uncertainty estimate is referenced to the average of all discharge measurements in the interlaboratory experiment, ignoring the technique bias. Simple equations can be used to assess the uncertainty of the uncertainty results, as a function of the number of participants and of repeated measurements. The interlaboratory method was applied to several interlaboratory experiments on ADCPs and currentmeters mounted on wading rods, in streams of different sizes and aspects, with 10 to 30 instruments, typically. The uncertainty results were consistent with the usual expert judgment and highly depended on the measurement environment. Approximately, the expanded uncertainties (within the 95% probability interval) were ±5% to ±10% for ADCPs in good or poor conditions, and ±10% to ±15% for currentmeters in shallow creeks. Due to the specific limitations related to a slow measurement process and to small, natural streams, uncertainty results for currentmeters were more uncertain than for ADCPs, for which the site-specific errors were significantly evidenced. The proposed method can be applied to a wide range of interlaboratory experiments conducted in contrasted environments for different streamgauging techniques, in a standardized way. Ideally, an international open database would enhance the investigation of hydrological data uncertainties, according to the characteristics of the measurement conditions and procedures. Such a dataset could be used for implementing and validating uncertainty propagation methods in hydrometry.

  18. Interlaboratory comparison of mineral constituents in a sample from the Herrin (No. 6) coal bed from Illinois

    USGS Publications Warehouse

    Finkelman, Robert B.; Fiene, F.L.; Miller, R.N.; Simon, F.O.

    1984-01-01

    Approximately 20 kg of the Herrin (No. 6) coal was collected from a strip mine in St. Clair County, Ill. A 10-kg portion was ground to -60 mesh, homogenized, and riffled into 128 splits of 70-80 g each. Homogeneity of these splits was confirmed by moisture, ash, and sulfur analyses of six randomly selected splits. Results of these analyses were within the ASTM (American Society for Testing and Materials) guidelines for interlaboratory precision. Splits of the Herrin (No. 6) coal were then transmitted to more than 30 laboratories for analysis. Low-temperature plasma oxidation was used to isolate inorganic matter for quantitative chemical and mineralogical analysis. Despite a wide variation in ashing conditions, only minor variations in ash yields were obtained; these variations were attributed to differences in operating temperature and moisture content. Mineralogical analyses of low-temperature ash (LTA) concentrates prepared by five different laboratories indicated variations within the limits of analytical error. The mean values, in weight percent, for the major minerals are as follows: calcite, 9; quartz, 20; pyrite, 23; kaolinite, 14; and illite+mixed-layer clays, 31. Normative mineralogical calculations and Fourier transform infrared analysis (FTIR) yielded results similar to those obtained from X-ray diffraction (XRD). Choosing appropriate mineral standards was found to be critical for the proper use of analytical techniques such as XRD and FTIR. Good interlaboratory agreement was obtained for most major, minor, and trace elements despite differences in analytical procedures and in the type of sample analyzed (coal, high-temperature ash, or LTA). Discrepancies between analyses for zinc, strontium, manganese, and iron may be attributed to sampling inhomogeneity problems. Mossbauer spectroscopy showed that approximately 44 percent of the pyritic sulfur was lost through weathering in the first year after preparation of the interlaboratory sample. Szomolnokite and possibly coquimbite and jarosite were also identified. Scanning electron microscopy studies indicated ubiquitous pyrite framboids and, less commonly, euhedral crystals, skeletal grains, irregularly shaped particles, and vein fillings. Minor accessory minerals such as rare-earth phosphates and possibly silicates, zircon, barium sulfate, titanium oxide, and sphalerite were also found. The textural evidence indicates that the minerals in the banded material are detrital whereas the minerals occurring as vein and pore fillings are authigenic. Magnetic measurements indicate that coal crushed in a steel pulverizer is contaminated by small quantities of abrasion fragments from the crusher, which seriously affect the measured magnetic properties of the coal.

  19. Compositional analysis of biomass reference materials: Results from an interlaboratory study

    DOE PAGES

    Templeton, David W.; Wolfrum, Edward J.; Yen, James H.; ...

    2015-10-29

    Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached andmore » an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original characterization, were quantified here.« less

  20. Interlaboratory study of the ion source memory effect in 36Cl accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Arnold, Maurice; Aumaître, Georges; Bourlès, Didier; Buchriegler, Josef; Golser, Robin; Keddadouche, Karim; Martschini, Martin; Merchel, Silke; Rugel, Georg; Steier, Peter

    2014-06-01

    Understanding and minimization of contaminations in the ion source due to cross-contamination and long-term memory effect is one of the key issues for accurate accelerator mass spectrometry (AMS) measurements of volatile elements. The focus of this work is on the investigation of the long-term memory effect for the volatile element chlorine, and the minimization of this effect in the ion source of the Dresden accelerator mass spectrometry facility (DREAMS). For this purpose, one of the two original HVE ion sources at the DREAMS facility was modified, allowing the use of larger sample holders having individual target apertures. Additionally, a more open geometry was used to improve the vacuum level. To evaluate this improvement in comparison to other up-to-date ion sources, an interlaboratory comparison had been initiated. The long-term memory effect of the four Cs sputter ion sources at DREAMS (two sources: original and modified), ASTER (Accélérateur pour les Sciences de la Terre, Environnement, Risques) and VERA (Vienna Environmental Research Accelerator) had been investigated by measuring samples of natural 35Cl/37Cl-ratio and samples highly-enriched in 35Cl (35Cl/37Cl ∼ 999). Besides investigating and comparing the individual levels of long-term memory, recovery time constants could be calculated. The tests show that all four sources suffer from long-term memory, but the modified DREAMS ion source showed the lowest level of contamination. The recovery times of the four ion sources were widely spread between 61 and 1390 s, where the modified DREAMS ion source with values between 156 and 262 s showed the fastest recovery in 80% of the measurements.

  1. Agreement in assessment of infliximab and adalimumab levels in rheumatoid arthritis: interlaboratory and interassay comparison.

    PubMed

    Valor, Lara; Hernández-Flórez, Diana; de la Torre, Inmaculada; Llinares, Francisca; Rosas, José; Yagüe, Jordi; Garrido, Jesús; Naredo, Esperanza

    2015-01-01

    Infliximab (IFX) and adalimumab (ADL) drug levels and anti-drug antibodies (ADA) are assessed using a variety of techniques, therefore, results cannot accurately be compared for clinical purposes. The aim of this study was to test two infliximab (IFX) and adalimumab (ADL) ELISA versions, for drug levels and ADA, to see whether they yield similar results. ELISA versions [Promonitor® IFX R1 and R2 (V.1), Promonitor® IFX and Anti-IFX (V.2); Promonitor® ADL R1 and R2 (V.1), Promonitor® ADL and Anti-ADL (V.2) kits (Progenika Biopharma, Spain)] were used to measure drug levels and ADA in IFX (n=24) and ADL (n=24) rheumatoid arthritis-treated patients in three independent laboratories. Quantitative and qualitative agreements were evaluated using intraclass correlation coefficients (ICC), and Cohen's Kappa (κ) respectively. The Bland-Altman plots assessed differences between V.1 and V.2. Interlaboratory agreement (ICC/κ) with V.1 was poor for IFX (0.66/0.62) and ADL (0.69/0.52) drug levels; meanwhile, high agreement was found with V.2 for IFX (0.98/0.95) and ADL (0.094/1.00). Comparison between V.1 and V.2 in each laboratory resulted in systematically higher values in V.2 than in V.1 and poor agreement (ICC/κ ranges) for IFX (0.12-0.7/ 0.19-0.42) and ADL (0.69-0.89 /0.50-0.73). Qualitative measurements result in better agreement, as evidenced in our study. Greater agreement in V.2 compared with V.1 for IFX and ADL levels could be due to a better tune up. Further studies are required to standardise methods to establish therapeutic reference ranges.

  2. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    PubMed

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  3. U.S. Geological Survey external quality-assurance project report to the National Atmospheric Deposition Program / National Trends Network and Mercury Deposition Network, 2007-08

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Latysh, Natalie E.; Chesney, Tanya A.

    2010-01-01

    The U.S. Geological Survey (USGS) used six distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program / National Trends Network (NTN) and Mercury Deposition Network (MDN) during 2007-08. The field-audit program assessed the effects of onsite exposure, sample handling, and shipping on the chemistry of NTN samples, and a system-blank program assessed the same effects for MDN. Two interlaboratory-comparison programs assessed the bias and variability of the chemical analysis data from the Central Analytical Laboratory (CAL), Mercury (Hg) Analytical Laboratory (HAL), and 12 other participating laboratories. A blind-audit program was also implemented for the MDN to evaluate analytical bias in HAL total Hg concentration data. A co-located-sampler program was used to identify and quantify potential shifts in NADP data resulting from replacement of original network instrumentation with new electronic recording rain gages (E-gages) and prototype precipitation collectors. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends of chemical constituents in wet deposition across the U.S. NADP data-quality objectives continued to be achieved during 2007-08. Results also indicate that retrofit of the NADP networks with the new E-gages is not likely to create step-function type shifts in NADP precipitation-depth records, except for sites where annual precipitation depth is dominated by snow because the E-gages tend to catch more snow than the original NADP rain gages. Evaluation of prototype precipitation collectors revealed no difference in sample volumes and analyte concentrations between the original NADP collectors and modified, deep-bucket collectors, but the Yankee Environmental Systems, Inc. (YES) collector obtained samples of significantly higher volumes and analyte concentrations than the standard NADP collector.

  4. Evaluation of Cardiac Toxicity Biomarkers in Rats from Different Laboratories

    PubMed Central

    Kim, Kyuri; Chini, Naseem; Fairchild, David G.; Engle, Steven K.; Reagan, William J.; Summers, Sandra D.; Mirsalis, Jon C.

    2016-01-01

    There is a great need for improved diagnostic and prognostic accuracy of potential cardiac toxicity in drug development. This study reports the evaluation of several commercially available biomarker kits by three institutions (SRI, Eli Lilly and Pfizer) for the discrimination between myocardial degeneration/necrosis and cardiac hypertrophy as well as the assessment of the inter-laboratory and inter-platform variation in results. Serum concentrations of natriuretic peptides (NT-proANP, NT-proBNP), cardiac and skeletal troponins (cTnI, cTnT, sTnI), myosin light chain 3 (Myl3) and fatty acid binding protein 3 (FABP3) were assessed in rats treated with minoxidil and isoproterenol. Minoxidil caused increased heart-to-body weight ratios and prominent elevations in NT-proANP and NT-proBNP concentrations detected at 24 hr postdose without elevation in troponins, Myl3 or FABP3 and with no abnormal histopathological findings. Isoproterenol caused ventricular leukocyte infiltration, myocyte fibrosis and necrosis with increased concentrations of the natriuretic peptides, cardiac troponins and Myl3. These results reinforce the advantages of a multi-marker strategy in elucidating the underlying cause of cardiac insult and detecting myocardial tissue damage at 24 hr post-treatment. The inter-laboratory and inter-platform comparison analyses also showed that the data obtained from different laboratories and platforms are highly correlated and reproducible, making these biomarkers widely applicable in preclinical studies. PMID:27638646

  5. Interlaboratory comparability, bias, and precision for four laboratories measuring constituents in precipitation, November 1982-August 1983

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Malo, B.A.

    1985-01-01

    Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)

  6. Interlaboratory evaluation of a standardized inductively coupled plasma mass spectrometry method for the determination of trace beryllium in air filter samples.

    PubMed

    Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L

    2009-12-01

    A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0.5, and 10 microg Be/filter, respectively. Overall recoveries were 93.2%, 102%, and 80.6% for the low, medium, and high beryllium loadings, respectively. Expanded uncertainty estimates for interlaboratory analysis of low, medium, and high beryllium loadings, calculated in accordance with ASTM D7440, were 18.8%, 19.8%, and 24.4%, respectively. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method, ASTM D7439.

  7. Trilateral interlaboratory with SSL (WLEDi) luminaire

    NASA Astrophysics Data System (ADS)

    Burini Junior, E. C.; Santos, E. R.; Assaf, L. O.

    2018-03-01

    The IEE/USP laboratory and two others, all belonging to RBLE (Brazilian Network of Test Laboratories) participated in a trilateral comparison performed from measurement independently of participants interaction. The results from electric and photometric measurements carried out on samples of Solid State Lighting - SSL, Inorganic White Light Emitting Diode (WLEDi) luminaires by three accredited laboratories were considered in order to point out mutual deviations and to verify the confidence in a bilateral comparison. The first analysis revealed a maximum deviation of 4.2 % between the luminous intensity attributed by one laboratory and the arithmetic mean value from three laboratories. The largest standard uncertainty value of 1.9 % was estimated for Total Harmonic Distortion of electric current THDi and the lowest value, 0.4 %, to the luminous flux. The extreme deviation for one parameter results was 7.2 % at maximum luminous intensity and the lowest was 1.7 % for luminous flux.

  8. Interlaboratory evaluation of trace element determination in workplace air filter samples by inductively coupled plasma mass spectrometry†‡

    PubMed Central

    Shulman, Stanley A.; Brisson, Michael J.; Howe, Alan M.

    2015-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter−1, with three different filter loadings denoted “Low”, “Medium” and “High”. Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter−1. Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study. PMID:22038017

  9. An interlaboratory study of TEX86 and BIT analysis of sediments, extracts, and standard mixtures

    NASA Astrophysics Data System (ADS)

    Schouten, Stefan; Hopmans, Ellen C.; Rosell-Melé, Antoni; Pearson, Ann; Adam, Pierre; Bauersachs, Thorsten; Bard, Edouard; Bernasconi, Stefano M.; Bianchi, Thomas S.; Brocks, Jochen J.; Carlson, Laura Truxal; Castañeda, Isla S.; Derenne, Sylvie; Selver, Ayça. Doǧrul; Dutta, Koushik; Eglinton, Timothy; Fosse, Celine; Galy, Valier; Grice, Kliti; Hinrichs, Kai-Uwe; Huang, Yongsong; Huguet, Arnaud; Huguet, Carme; Hurley, Sarah; Ingalls, Anitra; Jia, Guodong; Keely, Brendan; Knappy, Chris; Kondo, Miyuki; Krishnan, Srinath; Lincoln, Sara; Lipp, Julius; Mangelsdorf, Kai; Martínez-García, Alfredo; Ménot, Guillemette; Mets, Anchelique; Mollenhauer, Gesine; Ohkouchi, Naohiko; Ossebaar, Jort; Pagani, Mark; Pancost, Richard D.; Pearson, Emma J.; Peterse, Francien; Reichart, Gert-Jan; Schaeffer, Philippe; Schmitt, Gaby; Schwark, Lorenz; Shah, Sunita R.; Smith, Richard W.; Smittenberg, Rienk H.; Summons, Roger E.; Takano, Yoshinori; Talbot, Helen M.; Taylor, Kyle W. R.; Tarozo, Rafael; Uchida, Masao; van Dongen, Bart E.; Van Mooy, Benjamin A. S.; Wang, Jinxiang; Warren, Courtney; Weijers, Johan W. H.; Werne, Josef P.; Woltering, Martijn; Xie, Shucheng; Yamamoto, Masanobu; Yang, Huan; Zhang, Chuanlun L.; Zhang, Yige; Zhao, Meixun; Damsté, Jaap S. Sinninghe

    2013-12-01

    Two commonly used proxies based on the distribution of glycerol dialkyl glycerol tetraethers (GDGTs) are the TEX86 (TetraEther indeX of 86 carbon atoms) paleothermometer for sea surface temperature reconstructions and the BIT (Branched Isoprenoid Tetraether) index for reconstructing soil organic matter input to the ocean. An initial round-robin study of two sediment extracts, in which 15 laboratories participated, showed relatively consistent TEX86 values (reproducibility ±3-4°C when translated to temperature) but a large spread in BIT measurements (reproducibility ±0.41 on a scale of 0-1). Here we report results of a second round-robin study with 35 laboratories in which three sediments, one sediment extract, and two mixtures of pure, isolated GDGTs were analyzed. The results for TEX86 and BIT index showed improvement compared to the previous round-robin study. The reproducibility, indicating interlaboratory variation, of TEX86 values ranged from 1.3 to 3.0°C when translated to temperature. These results are similar to those of other temperature proxies used in paleoceanography. Comparison of the results obtained from one of the three sediments showed that TEX86 and BIT indices are not significantly affected by interlaboratory differences in sediment extraction techniques. BIT values of the sediments and extracts were at the extremes of the index with values close to 0 or 1, and showed good reproducibility (ranging from 0.013 to 0.042). However, the measured BIT values for the two GDGT mixtures, with known molar ratios of crenarchaeol and branched GDGTs, had intermediate BIT values and showed poor reproducibility and a large overestimation of the "true" (i.e., molar-based) BIT index. The latter is likely due to, among other factors, the higher mass spectrometric response of branched GDGTs compared to crenarchaeol, which also varies among mass spectrometers. Correction for this different mass spectrometric response showed a considerable improvement in the reproducibility of BIT index measurements among laboratories, as well as a substantially improved estimation of molar-based BIT values. This suggests that standard mixtures should be used in order to obtain consistent, and molar-based, BIT values.

  10. Validation of a quantitative cerebrospinal fluid alpha-synuclein assay in a European-wide interlaboratory study.

    PubMed

    Kruse, Niels; Persson, Staffan; Alcolea, Daniel; Bahl, Justyna M C; Baldeiras, Ines; Capello, Elisabetta; Chiasserini, Davide; Bocchio Chiavetto, Luisella; Emersic, Andreja; Engelborghs, Sebastiaan; Eren, Erden; Fladby, Tormod; Frisoni, Giovanni; García-Ayllón, María-Salud; Genc, Sermin; Gkatzima, Olymbia; Heegaard, Niels H H; Janeiro, André M; Kováčech, Branislav; Kuiperij, H Bea; Leitão, Maria J; Lleó, Alberto; Martins, Madalena; Matos, Mafalda; Mollergard, Hanne M; Nobili, Flavio; Öhrfelt, Annika; Parnetti, Lucilla; de Oliveira, Catarina Resende; Rot, Uros; Sáez-Valero, Javier; Struyfs, Hanne; Tanassi, Julia T; Taylor, Peggy; Tsolaki, Magda; Vanmechelen, Eugeen; Verbeek, Marcel M; Zilka, Norbert; Blennow, Kaj; Zetterberg, Henrik; Mollenhauer, Brit

    2015-09-01

    Decreased levels of alpha-synuclein (aSyn) in cerebrospinal fluid (CSF) in Parkinson's disease and related synucleinopathies have been reported, however, not consistently in all cross-sectional studies. To test the performance of one recently released human-specific enzyme-linked immunosorbent assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program - Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings. Recommendations for further validation experiments and improvement of the interlaboratory results obtained are given. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Accuracy of trace element determinations in alternate fuels

    NASA Technical Reports Server (NTRS)

    Greenbauer-Seng, L. A.

    1980-01-01

    A review of the techniques used at Lewis Research Center (LeRC) in trace metals analysis is presented, including the results of Atomic Absorption Spectrometry and DC Arc Emission Spectrometry of blank levels and recovery experiments for several metals. The design of an Interlaboratory Study conducted by LeRC is presented. Several factors were investigated, including: laboratory, analytical technique, fuel type, concentration, and ashing additive. Conclusions drawn from the statistical analysis will help direct research efforts toward those areas most responsible for the poor interlaboratory analytical results.

  12. Intercomparison of analytical methods for arsenic speciation in human urine.

    PubMed

    Crecelius, E; Yager, J

    1997-06-01

    An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l.

  13. Interlaboratory comparison of test results for detection of Lyme disease by 516 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Proficiency Testing Program.

    PubMed Central

    Bakken, L L; Callister, S M; Wand, P J; Schell, R F

    1997-01-01

    In 1991, we reported that 55% of laboratories participating in the Wisconsin Proficiency Testing Program could not accurately identify serum samples from Lyme disease patients containing antibody against Borrelia burgdorferi. The purpose of this study was to determine whether the accuracy of Lyme disease test results reported by approximately 500 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Lyme Disease Survey had improved. From 1992 through 1994, 50 serum samples were sent to participants of the survey. Each laboratory received 28 serum samples from individuals with Lyme disease according to the case definition of the Centers for Disease Control and Prevention and 22 serum samples from healthy individuals. Unfortunately, the serodiagnosis of Lyme disease by participants had not improved. The specificity of the Lyme disease assays steadily decreased from approximately 95% to approximately 81% during the 3-year period of the survey. False-positive test results approached 55% with some of the serum samples from healthy donors. A serum sample containing antibody against Treponema pallidum was reported as positive by 70% of the participants. In addition, the sensitivity fluctuated between 93 and 75%, depending upon the conjugate used by the laboratories. These results suggest that stronger criteria must be applied for approving and continuing to approve commercially available kits for the serodiagnosis of Lyme disease. PMID:9041384

  14. Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.

    An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less

  15. Determination of the moisture content of instant noodles: interlaboratory study.

    PubMed

    Hakoda, Akiko; Kasama, Hirotaka; Sakaida, Kenichi; Suzuki, Tadanao; Yasui, Akemi

    2006-01-01

    Determination of the moisture content of instant noodles, currently under discussion by the Codex Alimentarius Commission (CAC) requires 2 methods: one for fried noodles and the other for nonfried noodles. The method to determine the moisture content of fried noodles by drying at 105 degrees C for 2 h used in the Japanese Agricultural Standard (JAS) system of Japan can be applied to this purpose. In the present study, the JAS method for fried noodles was modified to be suitable for nonfried noodles by extending the drying time to 4 h. An interlaboratory study was conducted to evaluate interlaboratory performance statistics for these 2 methods. Ten participating laboratories each analyzed 5 test materials of fried and nonfried noodles as blind duplicates. After removal of outliers statistically, the repeatability (RSDr) and the reproducibility (RSD(R)) of these methods were 1.6-2.6 and 3.9-4.8% for fried noodles, and 0.3-1.5 and 1.3-2.9% for nonfried noodles, respectively.

  16. Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes

    DOE PAGES

    Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.; ...

    2018-04-19

    An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less

  17. Intra- and interlaboratory variability in acute toxicity tests with glochidia and juveniles of freshwater mussels (Unionidae)

    USGS Publications Warehouse

    Wang, N.; Augspurger, T.; Barnhart, M.C.; Bidwell, Joseph R.; Cope, W.G.; Dwyer, F.J.; Geis, S.; Greer, I.E.; Ingersoll, C.G.; Kane, C.M.; May, T.W.; Neves, R.J.; Newton, T.J.; Roberts, A.D.; Whites, D.W.

    2007-01-01

    The present study evaluated the performance and variability in acute toxicity tests with glochidia and newly transformed juvenile mussels using the standard methods outlined in American Society for Testing and Materials (ASTM). Multiple 48-h toxicity tests with glochidia and 96-h tests with juvenile mussels were conducted within a single laboratory and among five laboratories. All tests met the test acceptability requirements (e.g., ???90% control survival). Intralaboratory tests were conducted over two consecutive mussel-spawning seasons with mucket (Actinonaias ligamentina) or fatmucket (Lampsilis siliquoidea) using copper, ammonia, or chlorine as a toxicant. For the glochidia of both species, the variability of intralaboratory median effective concentrations (EC50s) for the three toxicants, expressed as the coefficient of variation (CV), ranged from 14 to 27% in 24-h exposures and from 13 to 36% in 48-h exposures. The intralaboratory CV of copper EC50s for juvenile fatmucket was 24% in 48-h exposures and 13% in 96-h exposures. Interlaboratory tests were conducted with fatmucket glochidia and juveniles by five laboratories using copper as a toxicant. The interlaboratory CV of copper EC50s for glochidia was 13% in 24-h exposures and 24% in 48-h exposures, and the interlaboratory CV for juveniles was 22% in 48-h exposures and 42% in 96-h exposures. The high completion success and the overall low variability in test results indicate that the test methods have acceptable precision and can be performed routinely. ?? 2007 SETAC.

  18. On the equivalence of generalized least-squares approaches to the evaluation of measurement comparisons

    NASA Astrophysics Data System (ADS)

    Koo, A.; Clare, J. F.

    2012-06-01

    Analysis of CIPM international comparisons is increasingly being carried out using a model-based approach that leads naturally to a generalized least-squares (GLS) solution. While this method offers the advantages of being easier to audit and having general applicability to any form of comparison protocol, there is a lack of consensus over aspects of its implementation. Two significant results are presented that show the equivalence of three differing approaches discussed by or applied in comparisons run by Consultative Committees of the CIPM. Both results depend on a mathematical condition equivalent to the requirement that any two artefacts in the comparison are linked through a sequence of measurements of overlapping pairs of artefacts. The first result is that a GLS estimator excluding all sources of error common to all measurements of a participant is equal to the GLS estimator incorporating all sources of error, including those associated with any bias in the standards or procedures of the measuring laboratory. The second result identifies the component of uncertainty in the estimate of bias that arises from possible systematic effects in the participants' measurement standards and procedures. The expression so obtained is a generalization of an expression previously published for a one-artefact comparison with no inter-participant correlations, to one for a comparison comprising any number of repeat measurements of multiple artefacts and allowing for inter-laboratory correlations.

  19. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in April 2001

    USGS Publications Warehouse

    Woodworth, M.T.; Connor, B.F.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  20. Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

    NASA Technical Reports Server (NTRS)

    Lisagor, W. B.

    1984-01-01

    Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

  1. Testing by artificial intelligence: computational alternatives to the determination of mutagenicity.

    PubMed

    Klopman, G; Rosenkranz, H S

    1992-08-01

    In order to develop methods for evaluating the predictive performance of computer-driven structure-activity methods (SAR) as well as to determine the limits of predictivity, we investigated the behavior of two Salmonella mutagenicity data bases: (a) a subset from the Genetox Program and (b) one from the U.S. National Toxicology Program (NTP). For molecules common to the two data bases, the experimental concordance was 76% when "marginals" were included and 81% when they were excluded. Three SAR methods were evaluated: CASE, MULTICASE and CASE/Graph Indices (CASE/GI). The programs "learned" the Genetox data base and used it to predict NTP molecules that were not present in the Genetox compilation. The concordances were 72, 80 and 47% respectively. Obviously, the MULTICASE version is superior and approaches the 85% interlaboratory variability observed for the Salmonella mutagenicity assays when the latter was carried out under carefully controlled conditions.

  2. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2002

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  3. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2001

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  4. Results of the U.S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2000

    USGS Publications Warehouse

    Farrar, Jerry W.; Copen, Ashley M.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  5. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 1999

    USGS Publications Warehouse

    Farrar, T.W.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  6. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in March 2003

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  7. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 2000

    USGS Publications Warehouse

    Connor, B.F.; Currier, J.P.; Woodworth, M.T.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  8. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    NASA Astrophysics Data System (ADS)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and Geoanalytical Research, 2004. 28(3): p. 411-416.

  9. Determination of 238u/235u, 236u/238u and uranium concentration in urine using sf-icp-ms and mc-icp-ms: an interlaboratory comparison.

    PubMed

    Parrish, Randall R; Thirlwall, Matthew F; Pickford, Chris; Horstwood, Matthew; Gerdes, Axel; Anderson, James; Coggon, David

    2006-02-01

    Accidental exposure to depleted or enriched uranium may occur in a variety of circumstances. There is a need to quantify such exposure, with the possibility that the testing may post-date exposure by months or years. Therefore, it is important to develop a very sensitive test to measure precisely the isotopic composition of uranium in urine at low levels of concentration. The results of an interlaboratory comparison using sector field (SF)-inductively coupled plasma-mass spectrometry (ICP-MS) and multiple collector (MC)-ICP-MS for the measurement of uranium concentration and U/U and U/U isotopic ratios of human urine samples are presented. Three urine samples were verified to contain uranium at 1-5 ng L and shown to have natural uranium isotopic composition. Portions of these urine batches were doped with depleted uranium (DU) containing small quantities of U, and the solutions were split into 100 mL and 400 mL aliquots that were subsequently measured blind by three laboratories. All methods investigated were able to measure accurately U/U with precisions of approximately 0.5% to approximately 4%, but only selected MC-ICP-MS methods were capable of consistently analyzing U/U to reasonable precision at the approximately 20 fg L level of U abundance. Isotope dilution using a U tracer demonstrates the ability to measure concentrations to better than +/-4% with the MC-ICP-MS method, though sample heterogeneity in urine samples was shown to be problematic in some cases. MC-ICP-MS outperformed SF-ICP-MS methods, as was expected. The MC-ICP-MS methodology described is capable of measuring to approximately 1% precision the U/U of any sample of human urine over the entire range of uranium abundance down to <1 ng L, and detecting very small amounts of DU contained therein.

  10. Summary findings of the fourth international radiocarbon intercomparison (FIRI)(1998-2001)

    NASA Astrophysics Data System (ADS)

    Boaretto, Elisabetta; Bryant, Charlotte; Carmi, Israel; Cook, Gordon; Gulliksen, Steinar; Harkness, Doug; Heinemeier, Jan; McClure, John; McGee, Edward; Naysmith, Philip; Possnert, Goran; Scott, Marian; van der Plicht, Hans; van Strydonck, Mark

    2002-10-01

    Interlaboratory comparisons have been widely used in applied radiocarbon science. These are an important part of ongoing quality assurance (QA) programmes, which are vital to the appropriate interpretation of the evidence provided by the 14C record in Quaternary applications (including climate change and environmental reconstruction). International comparisons of laboratory performance are an essential component of the quality assurance process in radiocarbon dating. If the user community is to have confidence in radiocarbon results, it needs to be assured that laboratories world wide are producing measurements that are reliable and in accordance with good practice. The findings from the most recent (completed in 2001) and extensive (more than 90 participating laboratories) radiocarbon intercomparison (FIRI) are reported here. This study was designed (i) to assess comparability, or otherwise, of the results from different laboratories and (ii) to quantify the extent and possible causes of any interlaboratory variation. The results demonstrate that there are no significant differences amongst the main measurement techniques (gas proportional counting, liquid scintillation counting and accelerator mass spectrometry (AMS)) but there is evidence of small laboratory offsets relative to known age samples for some laboratories. There is also evidence in some cases of underestimation of measurement precision. Approximately 10% of all results were classified as extreme (outliers) and these results were generated by 14% of the laboratories. Overall, the evidence supports the fact that radiocarbon laboratories are generally accurate and precise but that, notwithstanding internal QA procedures, some problems still occur, which can best be detected by participation in independent intercomparisons such as FIRI, where the results allow individual laboratories to assess their performance and to take remedial measures where necessary. The results from FIRI are significant in that they show a broad measure of agreement between measurements made in different laboratories on a wide range of materials and they also demonstrate no statistically significant difference between measurements made by radiometric or AMS techniques.

  11. Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS.

    PubMed

    Belsey, Natalie A; Cant, David J H; Minelli, Caterina; Araujo, Joyce R; Bock, Bernd; Brüner, Philipp; Castner, David G; Ceccone, Giacomo; Counsell, Jonathan D P; Dietrich, Paul M; Engelhard, Mark H; Fearn, Sarah; Galhardo, Carlos E; Kalbe, Henryk; Won Kim, Jeong; Lartundo-Rojas, Luis; Luftman, Henry S; Nunney, Tim S; Pseiner, Johannes; Smith, Emily F; Spampinato, Valentina; Sturm, Jacobus M; Thomas, Andrew G; Treacy, Jon P W; Veith, Lothar; Wagstaffe, Michael; Wang, Hai; Wang, Meiling; Wang, Yung-Chen; Werner, Wolfgang; Yang, Li; Shard, Alexander G

    2016-10-27

    We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) inter-laboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and; particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage or sample preparation resulted in a variability in thickness of 53 %. The calculation method chosen by XPS participants contributed a variability of 67 %. However, variability of 12 % was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors, since this contributed a variability of 33 %. The results from the LEIS participants were more consistent, with variability of less than 10 % in thickness and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.

  12. Algorithms and software for U-Pb geochronology by LA-ICPMS

    NASA Astrophysics Data System (ADS)

    McLean, Noah M.; Bowring, James F.; Gehrels, George

    2016-07-01

    The past 15 years have produced numerous innovations in geochronology, including experimental methods, instrumentation, and software that are revolutionizing the acquisition and application of geochronological data. For example, exciting advances are being driven by Laser-Ablation ICP Mass Spectrometry (LA-ICPMS), which allows for rapid determination of U-Th-Pb ages with 10s of micrometer-scale spatial resolution. This method has become the most commonly applied tool for dating zircons, constraining a host of geological problems. The LA-ICPMS community is now faced with archiving these data with associated analytical results and, more importantly, ensuring that data meet the highest standards for precision and accuracy and that interlaboratory biases are minimized. However, there is little consensus with regard to analytical strategies and data reduction protocols for LA-ICPMS geochronology. The result is systematic interlaboratory bias and both underestimation and overestimation of uncertainties on calculated dates that, in turn, decrease the value of data in repositories such as EarthChem, which archives data and analytical results from participating laboratories. We present free open-source software that implements new algorithms for evaluating and resolving many of these discrepancies. This solution is the result of a collaborative effort to extend the U-Pb_Redux software for the ID-TIMS community to the LA-ICPMS community. Now named ET_Redux, our new software automates the analytical and scientific workflows of data acquisition, statistical filtering, data analysis and interpretation, publication, community-based archiving, and the compilation and comparison of data from different laboratories to support collaborative science.

  13. Evaluation of Cardiac Toxicity Biomarkers in Rats from Different Laboratories.

    PubMed

    Kim, Kyuri; Chini, Naseem; Fairchild, David G; Engle, Steven K; Reagan, William J; Summers, Sandra D; Mirsalis, Jon C

    2016-12-01

    There is a great need for improved diagnostic and prognostic accuracy of potential cardiac toxicity in drug development. This study reports the evaluation of several commercially available biomarker kits by 3 institutions (SRI, Eli Lilly, and Pfizer) for the discrimination between myocardial degeneration/necrosis and cardiac hypertrophy as well as the assessment of the interlaboratory and interplatform variation in results. Serum concentrations of natriuretic peptides (N-terminal pro-atrial natriuretic peptide [NT-proANP] and N-terminal pro-brain natriuretic peptide [NT-proBNP]), cardiac and skeletal troponins (cTnI, cTnT, and sTnI), myosin light chain 3 (Myl3), and fatty acid binding protein 3 (FABP3) were assessed in rats treated with minoxidil (MNX) and isoproterenol (ISO). MNX caused increased heart-to-body weight ratios and prominent elevations in NT-proANP and NT-proBNP concentrations detected at 24-hr postdose without elevation in troponins, Myl3, or FABP3 and with no abnormal histopathological findings. ISO caused ventricular leukocyte infiltration, myocyte fibrosis, and necrosis with increased concentrations of the natriuretic peptides, cardiac troponins, and Myl3. These results reinforce the advantages of a multimarker strategy in elucidating the underlying cause of cardiac insult and detecting myocardial tissue damage at 24-hr posttreatment. The interlaboratory and interplatform comparison analyses also showed that the data obtained from different laboratories and platforms are highly correlated and reproducible, making these biomarkers widely applicable in preclinical studies.

  14. Interlaboratory studies and initiatives developing standards for proteomics

    PubMed Central

    Ivanov, Alexander R.; Colangelo, Christopher M.; Dufresne, Craig P.; Friedman, David B.; Lilley, Kathryn S.; Mechtler, Karl; Phinney, Brett S.; Rose, Kristie L.; Rudnick, Paul A.; Searle, Brian C.; Shaffer, Scott A.; Weintraub, Susan T.

    2013-01-01

    Proteomics is a rapidly transforming interdisciplinary field of research that embraces a diverse set of analytical approaches to tackle problems in fundamental and applied biology. This view-point article highlights the benefits of interlaboratory studies and standardization initiatives to enable investigators to address many of the challenges found in proteomics research. Among these initiatives, we discuss our efforts on a comprehensive performance standard for characterizing PTMs by MS that was recently developed by the Association of Biomolecular Resource Facilities (ABRF) Proteomics Standards Research Group (sPRG). PMID:23319436

  15. Role of the National Institute of Standards and Technology (NIST) in Support of the Vitamin D Initiative of the National Institutes of Health, Office of Dietary Supplements.

    PubMed

    Wise, Stephen A; Tai, Susan S-C; Burdette, Carolyn Q; Camara, Johanna E; Bedner, Mary; Lippa, Katrice A; Nelson, Michael A; Nalin, Federica; Phinney, Karen W; Sander, Lane C; Betz, Joseph M; Sempos, Christopher T; Coates, Paul M

    2017-09-01

    Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.

  16. NIST System for Measuring the Directivity Index of Hearing Aids under Simulated Real-Ear Conditions.

    PubMed

    Wagner, Randall P

    2013-01-01

    The directivity index is a parameter that is commonly used to characterize the performance of directional hearing aids, and is determined from the measured directional response. Since this response is different for a hearing aid worn on a person as compared to when it is in a free field, directivity index measurements of hearing aids are usually done under simulated real-ear conditions. Details are provided regarding the NIST system for measuring the hearing aid directivity index under these conditions and how this system is used to implement a standardized procedure for performing such measurements. This procedure involves a sampling method that utilizes sound source locations distributed in a semi-aligned zone array on an imaginary spherical surface surrounding a standardized acoustical test manikin. The capabilities of the system were demonstrated over the frequency range of one-third-octave bands with center frequencies from 200 Hz to 8000 Hz through NIST participation in an interlaboratory comparison. This comparison was conducted between eight different laboratories of members of Working Group S3/WG48, Hearing Aids, established by Accredited Standards Committee S3, Bioacoustics, which is administered by the Acoustical Society of America and accredited by the American National Standards Institute. Directivity measurements were made for a total of six programmed memories in two different hearing aids and for the unaided manikin with the manikin right pinna accompanying the aids. Omnidirectional, cardioid, and bidirectional response patterns were measured. Results are presented comparing the NIST data with the reference values calculated from the data reported by all participating laboratories.

  17. NIST System for Measuring the Directivity Index of Hearing Aids under Simulated Real-Ear Conditions

    PubMed Central

    Wagner, Randall P

    2013-01-01

    The directivity index is a parameter that is commonly used to characterize the performance of directional hearing aids, and is determined from the measured directional response. Since this response is different for a hearing aid worn on a person as compared to when it is in a free field, directivity index measurements of hearing aids are usually done under simulated real-ear conditions. Details are provided regarding the NIST system for measuring the hearing aid directivity index under these conditions and how this system is used to implement a standardized procedure for performing such measurements. This procedure involves a sampling method that utilizes sound source locations distributed in a semi-aligned zone array on an imaginary spherical surface surrounding a standardized acoustical test manikin. The capabilities of the system were demonstrated over the frequency range of one-third-octave bands with center frequencies from 200 Hz to 8000 Hz through NIST participation in an interlaboratory comparison. This comparison was conducted between eight different laboratories of members of Working Group S3/WG48, Hearing Aids, established by Accredited Standards Committee S3, Bioacoustics, which is administered by the Acoustical Society of America and accredited by the American National Standards Institute. Directivity measurements were made for a total of six programmed memories in two different hearing aids and for the unaided manikin with the manikin right pinna accompanying the aids. Omnidirectional, cardioid, and bidirectional response patterns were measured. Results are presented comparing the NIST data with the reference values calculated from the data reported by all participating laboratories. PMID:26401425

  18. Interlaboratory Evaluation of in Vitro Cytotoxicity and Inflammatory Responses to Engineered Nanomaterials: The NIEHS Nano GO Consortium

    PubMed Central

    Xia, Tian; Hamilton, Raymond F.; Bonner, James C.; Crandall, Edward D.; Elder, Alison; Fazlollahi, Farnoosh; Girtsman, Teri A.; Kim, Kwang; Mitra, Somenath; Ntim, Susana A.; Orr, Galya; Tagmount, Mani; Taylor, Alexia J.; Telesca, Donatello; Tolic, Ana; Vulpe, Christopher D.; Walker, Andrea J.; Wang, Xiang; Witzmann, Frank A.; Wu, Nianqiang; Xie, Yumei; Zink, Jeffery I.; Nel, Andre

    2013-01-01

    Background: Differences in interlaboratory research protocols contribute to the conflicting data in the literature regarding engineered nanomaterial (ENM) bioactivity. Objectives: Grantees of a National Institute of Health Sciences (NIEHS)-funded consortium program performed two phases of in vitro testing with selected ENMs in an effort to identify and minimize sources of variability. Methods: Consortium program participants (CPPs) conducted ENM bioactivity evaluations on zinc oxide (ZnO), three forms of titanium dioxide (TiO2), and three forms of multiwalled carbon nanotubes (MWCNTs). In addition, CPPs performed bioassays using three mammalian cell lines (BEAS-2B, RLE-6TN, and THP-1) selected in order to cover two different species (rat and human), two different lung epithelial cells (alveolar type II and bronchial epithelial cells), and two different cell types (epithelial cells and macrophages). CPPs also measured cytotoxicity in all cell types while measuring inflammasome activation [interleukin-1β (IL-1β) release] using only THP-1 cells. Results: The overall in vitro toxicity profiles of ENM were as follows: ZnO was cytotoxic to all cell types at ≥ 50 μg/mL, but did not induce IL-1β. TiO2 was not cytotoxic except for the nanobelt form, which was cytotoxic and induced significant IL-1β production in THP-1 cells. MWCNTs did not produce cytotoxicity, but stimulated lower levels of IL-1β production in THP-1 cells, with the original MWCNT producing the most IL-1β. Conclusions: The results provide justification for the inclusion of mechanism-linked bioactivity assays along with traditional cytotoxicity assays for in vitro screening. In addition, the results suggest that conducting studies with multiple relevant cell types to avoid false-negative outcomes is critical for accurate evaluation of ENM bioactivity. PMID:23649538

  19. [Statistical approach to evaluate the occurrence of out-of acceptable ranges and accuracy for antimicrobial susceptibility tests in inter-laboratory quality control program].

    PubMed

    Ueno, Tamio; Matuda, Junichi; Yamane, Nobuhisa

    2013-03-01

    To evaluate the occurrence of out-of acceptable ranges and accuracy of antimicrobial susceptibility tests, we applied a new statistical tool to the Inter-Laboratory Quality Control Program established by the Kyushu Quality Control Research Group. First, we defined acceptable ranges of minimum inhibitory concentration (MIC) for broth microdilution tests and inhibitory zone diameter for disk diffusion tests on the basis of Clinical and Laboratory Standards Institute (CLSI) M100-S21. In the analysis, more than two out-of acceptable range results in the 20 tests were considered as not allowable according to the CLSI document. Of the 90 participating laboratories, 46 (51%) experienced one or more occurrences of out-of acceptable range results. Then, a binomial test was applied to each participating laboratory. The results indicated that the occurrences of out-of acceptable range results in the 11 laboratories were significantly higher when compared to the CLSI recommendation (allowable rate < or = 0.05). The standard deviation indices(SDI) were calculated by using reported results, mean and standard deviation values for the respective antimicrobial agents tested. In the evaluation of accuracy, mean value from each laboratory was statistically compared with zero using a Student's t-test. The results revealed that 5 of the 11 above laboratories reported erroneous test results that systematically drifted to the side of resistance. In conclusion, our statistical approach has enabled us to detect significantly higher occurrences and source of interpretive errors in antimicrobial susceptibility tests; therefore, this approach can provide us with additional information that can improve the accuracy of the test results in clinical microbiology laboratories.

  20. External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 1997-99

    USGS Publications Warehouse

    Gordon, John D.; Latysh, Natalie E.; Lindholm, Sandy J.

    2003-01-01

    Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/ National Trends Network (NADP/NTN) during 1997 through 1999: the intersite-comparison program, the blind-audit program, the field- audit program, the interlaboratory-comparison program, and the collocated-sampler program. The intersite-comparison program assesses the accuracy of pH and specific-conductance determinations made by NADP/NTN site operators. In two 1997 intersite-comparison studies, 83.7 and 85.8 percent of the pH determinations met the NADP/NTN accuracy goals, whereas 97.3 and 92.4 percent of the specific-conductance determinations met the NADP/NTN accuracy goals. The percentage of pH and specific-conductance determinations that met the accuracy goals in 1998 were, for the most part, higher than in 1997. In two 1998 studies, 90.9 and 90.3 percent of the pH determinations met the accuracy goals compared to 94.7 and 96.0 percent of the specific- conductance measurements meeting the accuracy goals. In one 1999 intersite-comparison study, 89.5 percent and 99.4 percent of pH and specific- conductance determinations, respectively, met the NADP/NTN accuracy goals. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the analytical bias and precision of weekly precipitation samples. A portion of the blind-audit sample subject to the normal onsite handling and processing of a weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Positive bias in regard to blind-audit results indicates that the bucket portion has a higher concentration than the bottle portion. The paired t-test for the 1997 through 1999 blind- audit data indicates that routine sample handling, processing, and shipping introduced a positive bias (a=0.05) for calcium and chloride and a negative bias (cz=0.05) for hydrogen ion. During 1997 through 1999, the median paired differences between the bucket and bottle portions ranged from 0.00 milligram per liter for nitrate and ammonium to +0.010 milligram per liter for both chloride and sulfate. The median paired difference between the bucket and bottle portions for hydrogen ion was -1.086 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was -0.200 microsiemen per centimeter during 1997 through 1999. Surface-chemistry effects due to variable amounts of precipitation contacting prewashed sample-collection and shipping-container surfaces were studied in the blind-audit program by using three different sample volumes. The sample- collection and shipping containers used for the blind-audit study were obtained from the site operator's supply and could have been used for precipitation samples. Results of a Kruskal-Wallis analysis of variance test of the relation between paired blind-audit sample differences in units of concentration and sample volume were statistically significant for magnesium, chloride, sulfate, and hydrogen ion during 1997 through 1999. Before 1994, at least 5 of the 10 analytes displayed a statistically significant difference between paired blind-audit differences in units of concentration and sample volume, supporting the premise that chemical reactions between the 13-liter bucket shipping container (primarily the butadiene o-ring lid of the shipping container) and the sample, which resulted in an increasing loss of hydrogen ion with increasing volume, have been eliminated by the new l-liter bottle sample- shipping protocol. The field-audit program measures the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. In the field-audit program, the site operator is instructed to process and submit a quality- control sample following a standard 7-day, Tuesday-to-Tuesday sampling period with no

  1. Using an interlaboratory study to revise methods for conducting 10-d to 42-d water or sediment toxicity tests with Hyalella azteca

    USGS Publications Warehouse

    Ivey, Chris D.; Ingersoll, Christopher G.; Brumbaugh, William G.; Hammer, Edward J.; Mount, David R.; Hockett, J. Russell; Norberg-King, Teresa J.; Soucek, Dave; Taylor, Lisa

    2016-01-01

    Studies have been conducted to refine US Environmental Protection Agency, ASTM International, and Environment Canada standard methods for conducting 42-d reproduction tests with Hyalella azteca in water or in sediment. Modifications to the H. azteca method include better-defined ionic composition requirements for exposure water (i.e., >15 mg/L of chloride and >0.02 mg/L of bromide) and improved survival, growth, and reproduction with alternate diets provided as increased rations over time in water-only or whole-sediment toxicity tests. A total of 24 laboratories volunteered to participate in the present interlaboratory study evaluating the performance of H. azteca in 42-d studies in control sand or control sediment using the refined methods. Improved growth and reproduction of H. azteca was observed with 2 alternate diets of 1) ramped diatoms (Thalassiosira weissflogii) + ramped Tetramin or 2) yeast–cerophyll–trout chow (YCT) + ramped Tetramin, especially when compared with results from the traditional diet of 1.8 mg YCT/d. Laboratories were able to meet proposed test acceptability criteria and in most cases had lower variation in growth or reproduction compared with previous interlaboratory studies using the traditional YCT diet. Laboratory success in conducting 42-d H. azteca exposures benefited from adherence to several key requirements of the detailed testing, culturing, and handling methods. Results from the present interlaboratory study are being used to help revise standard methods for conducting 10-d to 42-d water or sediment toxicity exposures with H. azteca.

  2. Note: CO₂-mineral dissolution experiments using a rocking autoclave and a novel titanium reaction cell.

    PubMed

    Purser, Gemma; Rochelle, Christopher A; Wallis, Humphrey C; Rosenqvist, Jörgen; Kilpatrick, Andrew D; Yardley, Bruce W D

    2014-08-01

    A novel titanium reaction cell has been constructed for the study of water-rock-CO2 reactions. The reaction cell has been used within a direct-sampling rocking autoclave and offers certain advantages over traditional "flexible gold/titanium cell" approaches. The main advantage is robustness, as flexible cells are prone to rupture on depressurisation during gas-rich experiments. The reaction cell was tested in experiments during an inter-laboratory comparison study, in which mineral kinetic data were determined. The cell performed well during experiments up to 130 °C and 300 bars pressure. The data obtained were similar to those of other laboratories participating in the study, and also to previously published data.

  3. Intercomparison of analytical methods for arsenic speciation in human urine.

    PubMed Central

    Crecelius, E; Yager, J

    1997-01-01

    An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l. PMID:9288500

  4. Analysis of 161Tb by radiochemical separation and liquid scintillation counting

    DOE PAGES

    Jiang, J.; Davies, A.; Arrigo, L.; ...

    2015-12-05

    The determination of 161Tb activity is problematic due to its very low fission yield, short half-life, and the complication of its gamma spectrum. At AWE, radiochemically purified 161Tb solution was measured on a PerkinElmer 1220 Quantulus TM Liquid Scintillation Spectrometer. Since there was no 161Tb certified standard solution available commercially, the counting efficiency was determined by the CIEMAT/NIST Efficiency Tracing method. The method was validated during a recent inter-laboratory comparison exercise involving the analysis of a uranium sample irradiated with thermal neutrons. Lastly, the measured 161Tb result was in excellent agreement with the result using gamma spectrometry and the resultmore » obtained by Pacific Northwest National Laboratory.« less

  5. Comparison of two real-time RT-PCR assays for differentiation of C-strain vaccinated from classical swine fever infected pigs and wild boars.

    PubMed

    Widén, F; Everett, H; Blome, S; Fernandez Pinero, J; Uttenthal, A; Cortey, M; von Rosen, T; Tignon, M; Liu, L

    2014-10-01

    Classical swine fever is one of the most important infectious diseases for the pig industry worldwide due to its economic impact. Vaccination is an effective means to control disease, however within the EU its regular use is banned owing to the inability to differentiate infected and vaccinated animals, the so called DIVA principle. This inability complicates monitoring of disease and stops international trade thereby limiting use of the vaccine in many regions. The C-strain vaccine is safe to use and gives good protection. It is licensed for emergency vaccination in the EU in event of an outbreak. Two genetic assays that can distinguish between wild type virus and C-strain vaccines have recently been developed. Here the results from a comparison of these two real-time RT-PCR assays in an interlaboratory exercise are presented. Both assays showed similar performance. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Interlaboratory ring trial to evaluate CFT proficiency of European laboratories for diagnosis of glanders in equids.

    PubMed

    Laroucau, K; Colaneri, C; Jaÿ, M; Corde, Y; Drapeau, A; Durand, B; Zientara, S; Beck, C

    2016-06-18

    To evaluate the routine complement fixation test (CFT) used to detect Burkholderia mallei antibodies in equine sera, an interlaboratory proficiency test was held with 24 European laboratories, including 22 National Reference Laboratories for glanders. The panels sent to participants were composed of sera with or without B mallei antibodies. This study confirmed the reliability of CFT and highlighted its intralaboratory reproducibility. However, the sensitivity of glanders serodiagnosis and laboratory proficiency may be improved by standardising critical reagents, including antigens, and by developing a standard B mallei serum. British Veterinary Association.

  7. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828

  8. Implementation of a national reference laboratory for Buruli ulcer disease in Togo.

    PubMed

    Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.

  9. Manganese recycling in the United States in 1998

    USGS Publications Warehouse

    Jones, Thomas S.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  10. A Follow-Up of the Multicenter Collaborative Study on HIV-1 Drug Resistance and Tropism Testing Using 454 Ultra Deep Pyrosequencing

    PubMed Central

    St. John, Elizabeth P.; Simen, Birgitte B.; Turenchalk, Gregory S.; Braverman, Michael S.; Abbate, Isabella; Aerssens, Jeroen; Bouchez, Olivier; Gabriel, Christian; Izopet, Jacques; Meixenberger, Karolin; Di Giallonardo, Francesca; Schlapbach, Ralph; Paredes, Roger; Sakwa, James; Schmitz-Agheguian, Gudrun G.; Thielen, Alexander; Victor, Martin

    2016-01-01

    Background Ultra deep sequencing is of increasing use not only in research but also in diagnostics. For implementation of ultra deep sequencing assays in clinical laboratories for routine diagnostics, intra- and inter-laboratory testing are of the utmost importance. Methods A multicenter study was conducted to validate an updated assay design for 454 Life Sciences’ GS FLX Titanium system targeting protease/reverse transcriptase (RTP) and env (V3) regions to identify HIV-1 drug-resistance mutations and determine co-receptor use with high sensitivity. The study included 30 HIV-1 subtype B and 6 subtype non-B samples with viral titers (VT) of 3,940–447,400 copies/mL, two dilution series (52,129–1,340 and 25,130–734 copies/mL), and triplicate samples. Amplicons spanning PR codons 10–99, RT codons 1–251 and the entire V3 region were generated using barcoded primers. Analysis was performed using the GS Amplicon Variant Analyzer and geno2pheno for tropism. For comparison, population sequencing was performed using the ViroSeq HIV-1 genotyping system. Results The median sequencing depth across the 11 sites was 1,829 reads per position for RTP (IQR 592–3,488) and 2,410 for V3 (IQR 786–3,695). 10 preselected drug resistant variants were measured across sites and showed high inter-laboratory correlation across all sites with data (P<0.001). The triplicate samples of a plasmid mixture confirmed the high inter-laboratory consistency (mean% ± stdev: 4.6 ±0.5, 4.8 ±0.4, 4.9 ±0.3) and revealed good intra-laboratory consistency (mean% range ± stdev range: 4.2–5.2 ± 0.04–0.65). In the two dilutions series, no variants >20% were missed, variants 2–10% were detected at most sites (even at low VT), and variants 1–2% were detected by some sites. All mutations detected by population sequencing were also detected by UDS. Conclusions This assay design results in an accurate and reproducible approach to analyze HIV-1 mutant spectra, even at variant frequencies well below those routinely detectable by population sequencing. PMID:26756901

  11. United Nations Environment Programme Capacity Building Pilot Project--training and interlaboratory study on persistent organic pollutant analysis under the Stockholm Convention.

    PubMed

    de Boer, J; Leslie, H; van Leeuwen, S P J; Wegener, J-W; van Bavel, B; Lindström, G; Lahoutifard, N; Fiedler, H

    2008-06-09

    Within the framework of a United Nations Environment Programme (UNEP) Capacity Building Project for training of laboratory staff in developing countries on persistent organic pollutant (POP) analysis, an interlaboratory study was organised following an initial evaluation of the performance of laboratories (reality check) and a series of training sessions. The target compounds were polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP). Seven laboratories from five countries (Ecuador, Uruguay, Kenya, Moldova, and Fiji) participated. Most of the laboratories had no experience in determining PCBs. Although chromatograms improved considerably after the training and installation of new gas chromatographic (GC) columns at participating laboratories, the level of performance in the interlaboratory study was essentially on par with the moderate performance level achieved by European POP laboratories in the 1980s. Only some individual results were within +/-20% of the target values. The relative standard deviations (R.S.D.s) in POP concentrations determined by laboratories in a sediment sample were >200% in a number of cases. The results for a certified herring sample were better with at least some R.S.D. values below 50% and most below 100%. Clean up was as one of the main sources of error. After inspection it was ascertained that training of laboratory staff and investments in simple consumables such as glassware and GC columns would help to improve the quality of the analysis more than major investments in expensive instrumentation. Creating an effective network of POP laboratories at different continents together with a series of interlaboratory studies and workshops is suggested to improve the measurements of POPs in these countries.

  12. Evaluation of Gentian cystatin C reagent on Abbott Ci8200 and calculation of glomerular filtration rate expressed in mL/min/1.73 m(2) from the cystatin C values in mg/L.

    PubMed

    Flodin, M; Jonsson, A-S; Hansson, L-O; Danielsson, L-A; Larsson, A

    2007-01-01

    Estimation of the glomerular filtration rate (GFR) is essential when evaluating patients with kidney disease and treating patients with drugs eliminated from the circulation by the kidneys. Cystatin C has been shown in several studies to be superior to creatinine in the estimation of GFR. At our hospitals, there is an increasing demand for cystatin C and at present we perform approximately 1500 cystatin C analyses a month. We thus need the assay available 24 h/day and to have it on our routine chemistry instrument to minimize handling time per test and time to reported test results. We have evaluated a new cystatin C immunoassay from Gentian (Gentian, Moss, Norway) on Architect ci8200 (Abbott Laboratories, Abbott Park, Ill., USA). A prerequisite at our hospital is that cystatin C results are reported as a calculated GFR in mL/min/1.73 m(2), so we also made a comparison with iohexol clearance. The Gentian cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, Ill., USA) and good inter-laboratory concordance. The assay has very low total imprecision, good linearity and strong correlation with iohexol clearance (R (2) = 0.956). The equation for the correlation curve is: y = 79.901x(-1.4389). There was low inter-laboratory variation between the three laboratories involved in the cystatin C evaluation, and thus all three laboratories can use the same equation for calculating the estimated GFR.

  13. Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belsey, Natalie A.; Cant, David J. H.; Minelli, Caterina

    We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) inter-laboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and; particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage or sample preparation resulted in a variability in thickness of 53 %. The calculation methodmore » chosen by XPS participants contributed a variability of 67 %. However, variability of 12 % was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors, since this contributed a variability of 33 %. The results from the LEIS participants were more consistent, with variability of less than 10 % in thickness and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.« less

  14. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    NASA Astrophysics Data System (ADS)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  15. Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans - joint RENEB and EURADOS inter-laboratory comparisons.

    PubMed

    Ainsbury, Elizabeth; Badie, Christophe; Barnard, Stephen; Manning, Grainne; Moquet, Jayne; Abend, Michael; Antunes, Ana Catarina; Barrios, Lleonard; Bassinet, Celine; Beinke, Christina; Bortolin, Emanuela; Bossin, Lily; Bricknell, Clare; Brzoska, Kamil; Buraczewska, Iwona; Castaño, Carlos Huertas; Čemusová, Zina; Christiansson, Maria; Cordero, Santiago Mateos; Cosler, Guillaume; Monaca, Sara Della; Desangles, François; Discher, Michael; Dominguez, Inmaculada; Doucha-Senf, Sven; Eakins, Jon; Fattibene, Paola; Filippi, Silvia; Frenzel, Monika; Georgieva, Dimka; Gregoire, Eric; Guogyte, Kamile; Hadjidekova, Valeria; Hadjiiska, Ljubomira; Hristova, Rositsa; Karakosta, Maria; Kis, Enikő; Kriehuber, Ralf; Lee, Jungil; Lloyd, David; Lumniczky, Katalin; Lyng, Fiona; Macaeva, Ellina; Majewski, Matthaeus; Vanda Martins, S; McKeever, Stephen W S; Meade, Aidan; Medipally, Dinesh; Meschini, Roberta; M'kacher, Radhia; Gil, Octávia Monteiro; Montero, Alegria; Moreno, Mercedes; Noditi, Mihaela; Oestreicher, Ursula; Oskamp, Dominik; Palitti, Fabrizio; Palma, Valentina; Pantelias, Gabriel; Pateux, Jerome; Patrono, Clarice; Pepe, Gaetano; Port, Matthias; Prieto, María Jesús; Quattrini, Maria Cristina; Quintens, Roel; Ricoul, Michelle; Roy, Laurence; Sabatier, Laure; Sebastià, Natividad; Sholom, Sergey; Sommer, Sylwester; Staynova, Albena; Strunz, Sonja; Terzoudi, Georgia; Testa, Antonella; Trompier, Francois; Valente, Marco; Hoey, Olivier Van; Veronese, Ivan; Wojcik, Andrzej; Woda, Clemens

    2017-01-01

    RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.

  16. Inter-laboratory calibration of new silver orthophosphate comparison materials for the stable oxygen isotope analysis of phosphates.

    PubMed

    Halas, Stanislaw; Skrzypek, Grzegorz; Meier-Augenstein, Wolfram; Pelc, Andrzej; Kemp, Helen F

    2011-03-15

    Stable oxygen isotope compositions (δ(18)O values) of two commercial and one synthesized silver orthophosphate reagents have been determined on the VSMOW scale. The analyses were carried out in three different laboratories: lab (1) applying off-line oxygen extraction in the form of CO(2) which was analyzed on a dual inlet and triple collector isotope ratio mass spectrometer, while labs (2) and (3) employed an isotope ratio mass spectrometer coupled to a high-temperature conversion/elemental analyzer (TC/EA) where Ag(3)PO(4) samples were analyzed as CO in continuous flow mode. The δ(18)O values for the proposed new comparison materials were linked to the generally accepted δ(18)O values for Vennemann's TU-1 and TU-2 standards as well as for Ag(3)PO(4) extracted from NBS120c. The weighted average δ(18)O(VSMOW) values for the new comparison materials UMCS-1, UMCS-2 and AGPO-SCRI were determined to be + 32.60 (± 0.12), + 19.40 (± 0.12) and + 14.58 (± 0.13)‰, respectively. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Inter-lab proteomics: data mining in collaborative projects on the basis of the HUPO brain proteome project's pilot studies.

    PubMed

    Hamacher, Michael; Gröttrup, Bernd; Eisenacher, Martin; Marcus, Katrin; Park, Young Mok; Meyer, Helmut E; Kwon, Kyung-Hoon; Stephan, Christian

    2011-01-01

    Several projects were initiated by the Human Proteome Organisation (HUPO) focusing on the proteome analysis of distinct human organs. The initiative dedicated to the brain, its development and correlated diseases is the HUPO Brain Proteome Project (HUPO BPP). An objective data submission, storage, and reprocessing strategy have been established with the help of the results gained in a pilot study phase and within subsequent studies. The bioinformatic relevance of the data is drawn from the inter-laboratory comparisons as well as from the recalculation of all data sets submitted by the different groups. In the following, results of the single groups as well as the centralised reprocessing effort are summarised, demonstrating the added-value of this concerted work.

  18. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 2)].

    PubMed

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Yamada, Kyohei; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.

  19. Results of an interlaboratory method performance study for the size determination and quantification of silver nanoparticles in chicken meat by single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS).

    PubMed

    Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J

    2017-08-01

    Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.

  20. Qualitative PCR method for Roundup Ready soybean: interlaboratory study.

    PubMed

    Kodama, Takashi; Kasahara, Masaki; Minegishi, Yasutaka; Futo, Satoshi; Sawada, Chihiro; Watai, Masatoshi; Akiyama, Hiroshi; Teshima, Reiko; Kurosawa, Yasunori; Furui, Satoshi; Hino, Akihiro; Kitta, Kazumi

    2011-01-01

    Quantitative and qualitative methods based on PCR have been developed for genetically modified organisms (GMO). Interlaboratory studies were previously conducted for GMO quantitative methods; in this study, an interlaboratory study was conducted for a qualitative method for a GM soybean, Roundup Ready soy (RR soy), with primer pairs designed for the quantitative method of RR soy studied previously. Fourteen laboratories in Japan participated. Each participant extracted DNA from 1.0 g each of the soy samples containing 0, 0.05, and 0.10% of RR soy, and performed PCR with primer pairs for an internal control gene (Le1) and RR soy followed by agarose gel electrophoresis. The PCR product amplified in this PCR system for Le1 was detected from all samples. The sensitivity, specificity, and false-negative and false-positive rates of the method were obtained from the results of RR soy detection. False-negative rates at the level of 0.05 and 0.10% of the RR soy samples were 6.0 and 2.3%, respectively, revealing that the LOD of the method was somewhat below 0.10%. The current study demonstrated that the qualitative method would be practical for monitoring the labeling system of GM soy in kernel lots.

  1. Toward Improvements in Inter-laboratory Calibration of Argon Isotope Measurements

    NASA Astrophysics Data System (ADS)

    Hemming, S. R.; Deino, A. L.; Heizler, M. T.; Hodges, K. V.; McIntosh, W. C.; Renne, P. R.; Swisher, C. C., III; Turrin, B. D.; Van Soest, M. C.

    2015-12-01

    It is important to continue to develop strategies to improve our ability to compare results between laboratories chronometers. The U-Pb community has significantly reduced inter-laboratory biases with the application of a community tracer solution and the distribution of synthetic zircon solutions. Inevitably sample selection and processing and even biases in interpretations will still lead to some disagreements in the assignment of ages. Accordingly natural samples that are shared will be important for achievement of the highest levels of agreement. Analogous improvements in quality and inter-laboratory agreement of analytical aspects of Ar-Ar can be achieved through development of synthetic age standards in gas canisters with multiple pipettes to deliver various controlled amounts of argon to the mass spectrometer. A preliminary proof-of concept comes from the inter-laboratory calibration experiment for the 40Ar/39Ar community. This portable Argon Pipette Intercalibration System (APIS) consists of three 2.7 L canisters each equipped with three pipettes of 0.1, 0.2 and 0.4 cc volumes. The currently traveling APIS has the three canisters filled with air and 40Ar*/39Ar of 1.73 and canister 2 has a 40Ar*/39Ar of 40.98 (~ Alder Creek and Fish Canyon in the same irradiation). With these pipettes it is possible to combine them to provide 0.1, 0.2, 0.3 (0.1+0.2), 0.4, 0.5 (0.1+0.4), 0.6 (0.2+0.4), and 0.7 (0.1+0.2+0.4) cc. The configuration allows a simple test for inter-laboratory biases and for volume/pressure dependent mass fractionation on the measured ratios for a gas with a single argon isotope composition. Although not yet tested, it is also possible to mix gas from any one of the three canisters in proportions of these increments, allowing even more tightly controlled calibration of measurements. We suggest that ultimately each EARTHTIME lab should be equipped with such a system permanently, with a community plan for a traveling system to periodically repeat the inter-calibration tests. The composition(s) of such systems may not be the same for each lab, depending on the requirements of equipment and main age ranges targeted. But with a relatively small number of end member compositions it should be possible to greatly improve the calibration capability of the community.

  2. Report on the U.S. Geological Survey's Evaluation Program Standard Reference Samples Distributed in October 1995: T-137 (Trace Constituents), M-136 (Major Constituents), N-47 (Nutrient Constituents), N-48 (Nutrient Constituents), P-25 (Low Ionic Strength Constituents), and Hg-21 (Mercury)

    USGS Publications Warehouse

    Farrar, Jerry W.; Long, H. Keith

    1996-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  3. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1994; T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), and Hg-18 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  4. Report of the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1993; T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents, N-38 (nutrients), N-39 (nutrients), P-20 (low ionic strength, and Hg-16 (mercury)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1993-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  5. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples distributed in March 1999

    USGS Publications Warehouse

    Farrar, Jerry W.; Chleboun, Kimberly M.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  6. Molecular typing of Legionella pneumophila from air-conditioning cooling waters using mip gene, SBT, and FAFLP methods.

    PubMed

    Gong, Xiangli; Li, Juntao; Zhang, Ying; Hou, Shuiping; Qu, Pinghua; Yang, Zhicong; Chen, Shouyi

    2017-08-01

    Legionella spp. are important waterborne pathogens. Molecular typing has become an important method for outbreaks investigations and source tracking of Legionnaires. In a survey program conducted by the Guangzhou Center for Disease Control and Prevention, multiple serotypes Legionella pneumophila (L. pneumophila) were isolated from waters in air-conditioning cooling towers in urban Guangzhou region, China between 2008 and 2011. Three genotyping methods, mip (macrophage infectivity potentiator) genotyping, SBT (sequence-based typing), and FAFLP (fluorescent amplified fragment length polymorphism analysis) were used to type these waterborne L. pneumophila isolates. The three methods were capable of typing all the 134 isolates and a reference strain of L. pneumophila (ATCC33153), with discriminatory indices of 0.7034, 0.9218, and 0.9376, for the mip, SBT, and FAFLP methods respectively. Among the 9 serotypes of the 134 isolates, 10, 50, and 34 molecular types were detected by the mip, SBT, and FAFLP methods respectively. The mip genotyping and SBT typing are more feasible for inter-laboratory results sharing and comparison of different types of L. pneumophila. The SBT and FAFLP typing methods were rapid with higher discriminatory abilities. Combinations of two or more of the typing methods enables more accurate typing of Legionella isolates for outbreak investigations and source tracking of Legionnaires. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. An interlaboratory comparison of measurements from filament-stretching rheometers using common test fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anna, Shelley L.; McKinley, Gareth H.; Nguyen, Duc A.

    2001-01-01

    Following development of a filament-stretching extensional rheometer at Monash University, similar rheometers have been designed and built in other laboratories. To help validate the basic technique, a collaborative program was undertaken to compare results from several instruments. First, three test fluids prepared at the University of California at Berkeley were characterized in steady and transient shear flows there and at the Massachusetts Institute of Technology (M.I.T.), and then tested in extensional rheometers at M.I.T., Monash and the University of Toronto. Each fluid is a constant-viscosity solution of narrow-molecular-weight-distribution polystyrene dissolved in oligomeric polystyrene. The solute molecular weights are 2.0, 6.5,more » and 20 million g/mol, and the polymer concentration in each fluid is 0.05 wt.%. From linear viscoelastic measurements, the Zimm relaxation times of the fluids are found to be 3.7, 31, and 150 s, respectively. The scaling of relaxation times with molecular weight indicates better-than-theta solvent quality, a finding consistent with independent intrinsic viscometry measurements of equilibrium coil size. Each fluid was tested in the three filament stretching rheometers at similar Deborah numbers. Despite variations in instrument design and the general difficulty of the technique, transient Trouton ratios measured in the three instruments are shown to agree quantitatively.« less

  8. ORNL superconducting technology program for electric power systems

    NASA Astrophysics Data System (ADS)

    Hawsey, R. A.

    1994-04-01

    The Oak Ridge National Laboratory (ORNL) Superconducting Technology Program is conducted as part of a national effort by the US Department of Energy's Office of Energy Efficiency and Renewable Energy to develop the technology base needed by US industry for commercial development of electric power applications of high-temperature superconductivity. The two major elements of this program are conductor development and applications development. This document describes the major research and development activities for this program together with related accomplishments. The technical progress reported was summarized from information prepared for the FY 1993 Annual Program Review held July 28--29, 1993. This ORNL program is highly leveraged by the staff and other resources of US industry and universities. In fact, nearly three-fourths of the ORNL effort is devoted to industrial competitiveness projects with private companies. Interlaboratory teams are also in place on a number of industry-driven projects. Patent disclosures, working group meetings, staff exchanges, and joint publications and presentations ensure that there is technology transfer to US industry. Working together, the collaborative teams are making rapid progress in solving the scientific and technical issues necessary for the commercialization of long lengths of practical high-temperature superconductor wire and wire products.

  9. ORNL superconducting technology program for electric energy systems

    NASA Astrophysics Data System (ADS)

    Hawsey, R. A.

    1993-02-01

    The Oak Ridge National Laboratory (ORNL) Superconducting Technology Program is conducted as part of a national effort by the US Department of Energy's (DOE's) Office of Conservation and Renewable Energy to develop the technology base needed by US industry for commercial development of electric power applications of high-temperature superconductivity. The two major elements of this program are wire development and systems development. This document describes the major research and development activities for this program together with related accomplishments. The technical progress reported was summarized from information prepared for the FY-92 Peer Review of Projects, which was conducted by DOE's Office of Program Analysis, Office of Energy Research. This ORNL program is highly leveraged by the staff and other resources of US industry and universities. Interlaboratory teams are also in place on a number of industry-driven projects. Patent disclosures, working group meetings, staff exchanges, and joint publications and presentations ensure that there is technology transfer to US industry. Working together, the collaborative teams are making tremendous progress in solving the scientific and technical issues necessary for the commercialization of long lengths of practical high-temperature superconductor wire and wire products.

  10. Current activities in standardization of high-temperature, low-cycle-fatigue testing techniques in the United States

    NASA Technical Reports Server (NTRS)

    Verrilli, Michael J.; Ellis, J. Rodney; Swindeman, Robert W.

    1990-01-01

    The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.

  11. Destructive analysis capabilities for plutonium and uranium characterization at Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tandon, Lav; Kuhn, Kevin J; Drake, Lawrence R

    Los Alamos National Laboratory's (LANL) Actinide Analytical Chemistry (AAC) group has been in existence since the Manhattan Project. It maintains a complete set of analytical capabilities for performing complete characterization (elemental assay, isotopic, metallic and non metallic trace impurities) of uranium and plutonium samples in different forms. For a majority of the customers there are strong quality assurance (QA) and quality control (QC) objectives including highest accuracy and precision with well defined uncertainties associated with the analytical results. Los Alamos participates in various international and national programs such as the Plutonium Metal Exchange Program, New Brunswick Laboratory's (NBL' s) Safeguardsmore » Measurement Evaluation Program (SME) and several other inter-laboratory round robin exercises to monitor and evaluate the data quality generated by AAC. These programs also provide independent verification of analytical measurement capabilities, and allow any technical problems with analytical measurements to be identified and corrected. This presentation will focus on key analytical capabilities for destructive analysis in AAC and also comparative data between LANL and peer groups for Pu assay and isotopic analysis.« less

  12. Optimisation of an analytical method and results from the inter-laboratory comparison of the migration of regulated substances from food packaging into the new mandatory European Union simulant for dry foodstuffs.

    PubMed

    Jakubowska, Natalia; Beldì, Giorgia; Peychès Bach, Aurélie; Simoneau, Catherine

    2014-01-01

    This paper presents the outcome of the development, optimisation and validation at European Union level of an analytical method for using poly(2,6-diphenyl phenylene oxide--PPPO), which is stipulated in Regulation (EU) No. 10/2011, as food simulant E for testing specific migration from plastics into dry foodstuffs. Two methods for fortifying respectively PPPO and a low-density polyethylene (LDPE) film with surrogate substances that are relevant to food contact were developed. A protocol for cleaning the PPPO and an efficient analytical method were developed for the quantification of butylhydroxytoluene (BHT), benzophenone (BP), diisobutylphthalate (DiBP), bis(2-ethylhexyl) adipate (DEHA) and 1,2-cyclohexanedicarboxylic acid, diisononyl ester (DINCH) from PPPO. A protocol for a migration test from plastics using small migration cells was also developed. The method was validated by an inter-laboratory comparison (ILC) with 16 national reference laboratories for food contact materials in the European Union. This allowed for the first time data to be obtained on the precision and laboratory performance of both migration and quantification. The results showed that the validation ILC was successful even when taking into account the complexity of the exercise. The results showed that the method performance was 7-9% repeatability standard deviation (rSD) for most substances (regardless of concentration), with 12% rSD for the high level of BHT and for DiBP at very low levels. The reproducibility standard deviation results for the 16 European Union laboratories were in the range of 20-30% for the quantification from PPPO (for the three levels of concentrations of the five substances) and 15-40% from migration experiments from the fortified plastic at 60°C for 10 days and subsequent quantification. Considering the lack of data previously available in the literature, this work has demonstrated that the validation of a method is possible both for migration from a film and for quantification into a corresponding simulant for specific migration.

  13. Comparative tests of bench equipment for fuel control system testing of gas-turbine engine

    NASA Astrophysics Data System (ADS)

    Shendaleva, E. V.

    2018-04-01

    The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.

  14. EC comparison on the determination of 226Ra, 228Ra, 234U and 238U in water among European monitoring laboratories.

    PubMed

    Wätjen, U; Benedik, L; Spasova, Y; Vasile, M; Altzitzoglou, T; Beyermann, M

    2010-01-01

    In anticipation of new European requirements for monitoring radioactivity concentration in drinking water, IRMM organized an interlaboratory comparison on the determination of low levels of activity concentrations (about 10-100 mBq L(-1)) of the naturally occurring radionuclides (226)Ra, (228)Ra, (234)U and (238)U in three commercially available mineral waters. Using two or three different methods with traceability to the International System of Reference (SIR), the reference values of the water samples were determined prior to the proficiency test within combined standard uncertainties of the order of 3%-10%. An overview of radiochemical separation and measurement methods used by the 45 participating laboratories are given. The results of the participants are evaluated versus the reference values. Several of the participants' results deviate by more than a factor of two from the reference values, in particular for the radium isotopes. Such erroneous analysis results may lead to a crucial omission of remedial actions on drinking water supplies or to economic loss by an unjustified action. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. AN INTERLABORATORY COMPARISON ON THE DETERMINATION OF 241Am, 244Cm AND 252Cf IN URINE.

    PubMed

    Gerstmann, Udo C; Taubner, Kerstin; Hartmann, Martina

    2016-09-01

    An intercomparison exercise on the determination of (241)Am, (244)Cm and (252)Cf in urine was performed. Since it was designed with regard to emergency preparedness, the detection limit for each nuclide was set to 0.1 Bq per 24-h urine sample. Most of the participating laboratories were established bioassay laboratories. However, some laboratories that routinely determine (241)Am only in environmental samples were also invited in order to explore their potential for emergency bioassay analysis. Another aspect of the intercomparison was to investigate the performance of all laboratories concerning the chemical yields of the (243)Am tracer in comparison with (244)Cm and (252)Cf. In summary, both types of laboratories showed good results. There was a negative bias for the results of (244)Cm and (252)Cf, which can be explained by slightly different radiochemical behaviours of americium, curium and californium and which is in agreement with results reported in the literature. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Inter-laboratory variation in the chemical analysis of acidic forest soil reference samples from eastern North America

    USGS Publications Warehouse

    Ross, Donald S.; Bailiey, Scott W; Briggs, Russell D; Curry, Johanna; Fernandez, Ivan J.; Fredriksen, Guinevere; Goodale, Christine L.; Hazlett, Paul W.; Heine, Paul R; Johnson, Chris E.; Larson, John T; Lawrence, Gregory B.; Kolka, Randy K; Ouimet, Rock; Pare, D; Richter, Daniel D.; Shirmer, Charles D; Warby, Richard A.F.

    2015-01-01

    Long-term forest soil monitoring and research often requires a comparison of laboratory data generated at different times and in different laboratories. Quantifying the uncertainty associated with these analyses is necessary to assess temporal changes in soil properties. Forest soil chemical properties, and methods to measure these properties, often differ from agronomic and horticultural soils. Soil proficiency programs do not generally include forest soil samples that are highly acidic, high in extractable Al, low in extractable Ca and often high in carbon. To determine the uncertainty associated with specific analytical methods for forest soils, we collected and distributed samples from two soil horizons (Oa and Bs) to 15 laboratories in the eastern United States and Canada. Soil properties measured included total organic carbon and nitrogen, pH and exchangeable cations. Overall, results were consistent despite some differences in methodology. We calculated the median absolute deviation (MAD) for each measurement and considered the acceptable range to be the median 6 2.5 3 MAD. Variability among laboratories was usually as low as the typical variability within a laboratory. A few areas of concern include a lack of consistency in the measurement and expression of results on a dry weight basis, relatively high variability in the C/N ratio in the Bs horizon, challenges associated with determining exchangeable cations at concentrations near the lower reporting range of some laboratories and the operationally defined nature of aluminum extractability. Recommendations include a continuation of reference forest soil exchange programs to quantify the uncertainty associated with these analyses in conjunction with ongoing efforts to review and standardize laboratory methods.

  17. Interlaboratory Evaluation of in Vitro Cytotoxicity and Inflammatory Responses to Engineered Nanomaterials: The NIEHS Nano GO Consortium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Tian; Hamilton, Raymond F.; Bonner, James C.

    2013-06-01

    Background: Differences in interlaboratory research protocols contribute to the conflicting data in the literature regarding engineered nanomaterial (ENM) bioactivity. Objectives: Grantees of a National Institute of Health Sciences (NIEHS)-funded consortium program performed two phases of in vitro testing with selected ENMs in an effort to identify and minimize sources of variability. Methods: Consortium program participants (CPPs) conducted ENM bioactivity evaluations on zinc oxide (ZnO), three forms of titanium dioxide (TiO2), and three forms of multiwalled carbon nanotubes (MWCNTs). In addition, CPPs performed bioassays using three mammalian cell lines (BEAS-2B, RLE-6TN, and THP-1) selected in order to cover two different speciesmore » (rat and human), two different lung epithelial cells (alveolar type II and bronchial epithelial cells), and two different cell types (epithelial cells and macrophages). CPPs also measured cytotoxicity in all cell types while measuring inflammasome activation [interleukin-1β (IL-1β) release] using only THP-1 cells. Results: The overall in vitro toxicity profiles of ENM were as follows: ZnO was cytotoxic to all cell types at ≥ 50 μ g/mL, but did not induce IL-1β. TiO2 was not cytotoxic except for the nanobelt form, which was cytotoxic and induced significant IL-1β production in THP-1 cells. MWCNTs did not produce cytotoxicity, but stimulated lower levels of IL-1β production in THP-1 cells, with the original MWCNT producing the most IL-1β. Conclusions: The results provide justification for the inclusion of mechanism-linked bioactivity assays along with traditional cytotoxicity assays for in vitro screening. In addition, the results suggest that conducting studies with multiple relevant cell types to avoid false-negative outcomes is critical for accurate evaluation of ENM bioactivity.« less

  18. Comparison of Hepatic 2D Sandwich Cultures and 3D Spheroids for Long-term Toxicity Applications: A Multicenter Study

    PubMed Central

    Bell, Catherine C; Dankers, Anita C A; Sison-Young, Rowena; Jenkins, Roz; Rowe, Cliff; Goldring, Chris E; Park, Kevin; Regan, Sophie L; Walker, Tracy; Schofield, Chris; Baze, Audrey; Foster, Alison J; Williams, Dominic P; van de Ven, Amy W M; Jacobs, Frank; van Houdt, Jos; Lähteenmäki, Tuula; Snoeys, Jan; Juhila, Satu; Richert, Lysiane; Ingelman-Sundberg, Magnus

    2018-01-01

    Abstract Primary human hepatocytes (PHHs) are commonly used for in vitro studies of drug-induced liver injury. However, when cultured as 2D monolayers, PHH lose crucial hepatic functions within hours. This dedifferentiation can be ameliorated when PHHs are cultured in sandwich configuration (2Dsw), particularly when cultures are regularly re-overlaid with extracellular matrix, or as 3D spheroids. In this study, the 6 participating laboratories evaluated the robustness of these 2 model systems made from cryopreserved PHH from the same donors considering both inter-donor and inter-laboratory variability and compared their suitability for use in repeated-dose toxicity studies using 5 different hepatotoxins with different toxicity mechanisms. We found that expression levels of proteins involved in drug absorption, distribution, metabolism, and excretion, as well as catalytic activities of 5 different CYPs, were significantly higher in 3D spheroid cultures, potentially affecting the exposure of the cells to drugs and their metabolites. Furthermore, global proteomic analyses revealed that PHH in 3D spheroid configuration were temporally stable whereas proteomes from the same donors in 2Dsw cultures showed substantial alterations in protein expression patterns over the 14 days in culture. Overall, spheroid cultures were more sensitive to the hepatotoxic compounds investigated, particularly upon long-term exposures, across testing sites with little inter-laboratory or inter-donor variability. The data presented here suggest that repeated-dosing regimens improve the predictivity of in vitro toxicity assays, and that PHH spheroids provide a sensitive and robust system for long-term mechanistic studies of drug-induced hepatotoxicity, whereas the 2Dsw system has a more dedifferentiated phenotype and lower sensitivity to detect hepatotoxicity. PMID:29329425

  19. cSRM 2035: a rare-earth oxide glass for the wavelength calibration of near-infrared dispersive and Fourier transform spectrometers

    NASA Astrophysics Data System (ADS)

    Choquette, Steven J.; Travis, John C.; Duewer, David L.

    1998-10-01

    The National Institute of Standards and Technology is developing an optical filter standard for calibration of the wavelength axis of near infrared (NIR) transmission spectrometers. A design goal for the initial candidate Standard Reference Material (cSRM) filter was to provide absorbance peaks evenly covering the spectral region between 800 nm to 1600 mm (12,000 cm-1 to 6,500 cm-1). The reproducibility of the peak location, for batch-certified filters, was to be better than 0.02 nm (approximately 0.1 cm-1). Glasses with 1 to 3 mole % Yb2O3, Sm2O3, and Nd2O3, incorporated into a commercial lanthanum oxide glass were evaluated for this proposed optical standard. An initial batch of cSRM 2035 filters was prepared based on studies of glasses made and evaluated in our laboratory. An interlaboratory comparison study was initiated in February 1997 to evaluate the utility of these filters for the chemical, pharmaceutical, instrumentation, and regulatory communities. Information concerning peak-picking algorithms, wavelength coverage, geometry preferences, and other parameters was solicited from the users. Based upon input from the participants of this interlaboratory study, we are making several changes to make SRM 2035 more useful to our customers. Two of these changes are: (1) incorporating Ho2O3 into the glass to introduce an absorbance peak at approximately 2000 nm (approximately 5000 cm-1) and (2) providing users with a standard center of gravity (COG) peak-picking algorithm to locate the absorbance peaks of the SRM filter precisely. Recent results have demonstrated that the COG method provides a 10 fold improvement in the precision of locating peaks compared with traditional peak-picking methods.

  20. Interlaboratory Study on Differential Analysis of Protein Glycosylation by Mass Spectrometry: The ABRF Glycoprotein Research Multi-Institutional Study 2012*

    PubMed Central

    Leymarie, Nancy; Griffin, Paula J.; Jonscher, Karen; Kolarich, Daniel; Orlando, Ron; McComb, Mark; Zaia, Joseph; Aguilan, Jennifer; Alley, William R.; Altmann, Friederich; Ball, Lauren E.; Basumallick, Lipika; Bazemore-Walker, Carthene R.; Behnken, Henning; Blank, Michael A.; Brown, Kristy J.; Bunz, Svenja-Catharina; Cairo, Christopher W.; Cipollo, John F.; Daneshfar, Rambod; Desaire, Heather; Drake, Richard R.; Go, Eden P.; Goldman, Radoslav; Gruber, Clemens; Halim, Adnan; Hathout, Yetrib; Hensbergen, Paul J.; Horn, David M.; Hurum, Deanna; Jabs, Wolfgang; Larson, Göran; Ly, Mellisa; Mann, Benjamin F.; Marx, Kristina; Mechref, Yehia; Meyer, Bernd; Möginger, Uwe; Neusüβ, Christian; Nilsson, Jonas; Novotny, Milos V.; Nyalwidhe, Julius O.; Packer, Nicolle H.; Pompach, Petr; Reiz, Bela; Resemann, Anja; Rohrer, Jeffrey S.; Ruthenbeck, Alexandra; Sanda, Miloslav; Schulz, Jan Mirco; Schweiger-Hufnagel, Ulrike; Sihlbom, Carina; Song, Ehwang; Staples, Gregory O.; Suckau, Detlev; Tang, Haixu; Thaysen-Andersen, Morten; Viner, Rosa I.; An, Yanming; Valmu, Leena; Wada, Yoshinao; Watson, Megan; Windwarder, Markus; Whittal, Randy; Wuhrer, Manfred; Zhu, Yiying; Zou, Chunxia

    2013-01-01

    One of the principal goals of glycoprotein research is to correlate glycan structure and function. Such correlation is necessary in order for one to understand the mechanisms whereby glycoprotein structure elaborates the functions of myriad proteins. The accurate comparison of glycoforms and quantification of glycosites are essential steps in this direction. Mass spectrometry has emerged as a powerful analytical technique in the field of glycoprotein characterization. Its sensitivity, high dynamic range, and mass accuracy provide both quantitative and sequence/structural information. As part of the 2012 ABRF Glycoprotein Research Group study, we explored the use of mass spectrometry and ancillary methodologies to characterize the glycoforms of two sources of human prostate specific antigen (PSA). PSA is used as a tumor marker for prostate cancer, with increasing blood levels used to distinguish between normal and cancer states. The glycans on PSA are believed to be biantennary N-linked, and it has been observed that prostate cancer tissues and cell lines contain more antennae than their benign counterparts. Thus, the ability to quantify differences in glycosylation associated with cancer has the potential to positively impact the use of PSA as a biomarker. We studied standard peptide-based proteomics/glycomics methodologies, including LC-MS/MS for peptide/glycopeptide sequencing and label-free approaches for differential quantification. We performed an interlaboratory study to determine the ability of different laboratories to correctly characterize the differences between glycoforms from two different sources using mass spectrometry methods. We used clustering analysis and ancillary statistical data treatment on the data sets submitted by participating laboratories to obtain a consensus of the glycoforms and abundances. The results demonstrate the relative strengths and weaknesses of top-down glycoproteomics, bottom-up glycoproteomics, and glycomics methods. PMID:23764502

  1. High resolution ID-ICP-MS certification of an estuary water reference material (LGC 6016) and analysis of matrix induced polyatomic interferences.

    PubMed

    Evans, P; Fairman, B

    2001-10-01

    Reliable trace metal analysis of environmental samples is dependent upon the availability of high accuracy, matrix reference standards. Here, we present Cd, Cu, Ni, Pb and Zn isotope dilution determination for an estuary water certified reference material (LGC 6016). This work highlights the need for high-accuracy techniques in the development of trace element CRMs rather than conventional inter-laboratory trials. Certification of the estuary water LGC6016 was initially determined from a consensus mean from 14 laboratories but this was found to be unsatisfactory due to the large discrepancies in the reported concentrations. The material was re-analysed using isotope dilution ICP-MS techniques. Pb and Cd were determined using a conventional quadrupole ICP-MS (Elan 5000). Cu, Zn and Ni were determined using a magnetic sector ICP-MS (Finnigan Element), which allowed significant polyatomic interferences to be overcome. Using the magnetic sector instrument, precise mass calibration to within 0.02 amu permitted identification of the interferences. Most interferences derived from the sample matrix. For example, the high Na content causes interferences on 63Cu, due to the formation of 40Ar23Na and 23Na2 16O1H, which in a conventional quadrupole instrument would relate to an erroneous increase in signal intensity by up to 20%. For each analyte a combined uncertainty calculation was performed following the Eurachem/GTAC and ISO guideline. For each element a combined uncertainty of 2-3% was found, which represents a 10-fold improvement compared to certification by inter-laboratory comparison. Analysis of the combined uncertainty budget indicates that the majority of systematic uncertainty derives from the instrumental isotope ratio measurements.

  2. Human and methodological sources of variability in the measurement of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine.

    PubMed

    Barregard, Lars; Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J; Weimann, Allan; Poulsen, Henrik E; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J; Santella, Regina M; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen; Cooke, Marcus S

    2013-06-20

    Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.

  3. Application of a Novel DCPD Adjustment Method for the J-R Curve Characterization: A study based on ORNL and ASTM Interlaboratory Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiang; Sokolov, Mikhail A; Nanstad, Randy K

    Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especiallymore » in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.« less

  4. International interlaboratory study comparing single organism 16S rRNA gene sequencing data: Beyond consensus sequence comparisons

    PubMed Central

    Olson, Nathan D.; Lund, Steven P.; Zook, Justin M.; Rojas-Cornejo, Fabiola; Beck, Brian; Foy, Carole; Huggett, Jim; Whale, Alexandra S.; Sui, Zhiwei; Baoutina, Anna; Dobeson, Michael; Partis, Lina; Morrow, Jayne B.

    2015-01-01

    This study presents the results from an interlaboratory sequencing study for which we developed a novel high-resolution method for comparing data from different sequencing platforms for a multi-copy, paralogous gene. The combination of PCR amplification and 16S ribosomal RNA gene (16S rRNA) sequencing has revolutionized bacteriology by enabling rapid identification, frequently without the need for culture. To assess variability between laboratories in sequencing 16S rRNA, six laboratories sequenced the gene encoding the 16S rRNA from Escherichia coli O157:H7 strain EDL933 and Listeria monocytogenes serovar 4b strain NCTC11994. Participants performed sequencing methods and protocols available in their laboratories: Sanger sequencing, Roche 454 pyrosequencing®, or Ion Torrent PGM®. The sequencing data were evaluated on three levels: (1) identity of biologically conserved position, (2) ratio of 16S rRNA gene copies featuring identified variants, and (3) the collection of variant combinations in a set of 16S rRNA gene copies. The same set of biologically conserved positions was identified for each sequencing method. Analytical methods using Bayesian and maximum likelihood statistics were developed to estimate variant copy ratios, which describe the ratio of nucleotides at each identified biologically variable position, as well as the likely set of variant combinations present in 16S rRNA gene copies. Our results indicate that estimated variant copy ratios at biologically variable positions were only reproducible for high throughput sequencing methods. Furthermore, the likely variant combination set was only reproducible with increased sequencing depth and longer read lengths. We also demonstrate novel methods for evaluating variable positions when comparing multi-copy gene sequence data from multiple laboratories generated using multiple sequencing technologies. PMID:27077030

  5. Detection of EGFR Variants in Plasma: A Multilaboratory Comparison of the cobas EGFR Mutation Test v2 in Europe.

    PubMed

    Keppens, Cleo; Palma, John F; Das, Partha M; Scudder, Sidney; Wen, Wei; Normanno, Nicola; Van Krieken, J Han; Sacco, Alessandra; Fenizia, Francesca; de Castro, David Gonzalez; Hönigschnabl, Selma; Kern, Izidor; Lopez-Rios, Fernando; Lozano, Maria D; Marchetti, Antonio; Halfon, Philippe; Schuuring, Ed; Setinek, Ulrike; Sorensen, Boe; Taniere, Phillipe; Tiemann, Markus; Vosmikova, Hana; Dequeker, Elisabeth M C

    2018-04-25

    Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small-cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of the cobas EGFR Mutation Test v2 to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild-type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per mL. The circulating tumor DNA was extracted by the cobas cfDNA Sample Preparation kit, followed by duplicate analysis with the EGFRv2 kit (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. Specificities were all 98.8% to 100.0%. Coefficients of variation indicated good intra and interlaboratory repeatability and reproducibility, but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the pre-defined copy number and the observed semiquantitative index values which reflects the samples' plasma mutation load. This study demonstrates an overall robust performance of the EGFRv2 kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  6. Development and inter-laboratory assessment of droplet digital PCR assays for multiplex quantification of 15 genetically modified soybean lines.

    PubMed

    Košir, Alexandra Bogožalec; Spilsberg, Bjørn; Holst-Jensen, Arne; Žel, Jana; Dobnik, David

    2017-08-17

    Quantification of genetically modified organisms (GMOs) in food and feed products is often required for their labelling or for tolerance thresholds. Standard-curve-based simplex quantitative polymerase chain reaction (qPCR) is the prevailing technology, which is often combined with screening analysis. With the rapidly growing number of GMOs on the world market, qPCR analysis becomes laborious and expensive. Innovative cost-effective approaches are therefore urgently needed. Here, we report the development and inter-laboratory assessment of multiplex assays to quantify GMO soybean using droplet digital PCR (ddPCR). The assays were developed to facilitate testing of foods and feed for compliance with current GMO regulations in the European Union (EU). Within the EU, the threshold for labelling is 0.9% for authorised GMOs per ingredient. Furthermore, the EU has set a technical zero tolerance limit of 0.1% for certain unauthorised GMOs. The novel multiplex ddPCR assays developed target 11 GMO soybean lines that are currently authorised, and four that are tolerated, pending authorisation in the EU. Potential significant improvements in cost efficiency are demonstrated. Performance was assessed for the critical parameters, including limits of detection and quantification, and trueness, repeatability, and robustness. Inter-laboratory performance was also determined on a number of proficiency programme and real-life samples.

  7. An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun

    Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less

  8. New reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.

    1993-01-01

    Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.

  9. Extension of the validation of AOAC Official Method 2005.06 for dc-GTX2,3: interlaboratory study.

    PubMed

    Ben-Gigirey, Begoña; Rodríguez-Velasco, María L; Gago-Martínez, Ana

    2012-01-01

    AOAC Official Method(SM) 2005.06 for the determination of saxitoxin (STX)-group toxins in shellfish by LC with fluorescence detection with precolumn oxidation was previously validated and adopted First Action following a collaborative study. However, the method was not validated for all key STX-group toxins, and procedures to quantify some of them were not provided. With more STX-group toxin standards commercially available and modifications to procedures, it was possible to overcome some of these difficulties. The European Union Reference Laboratory for Marine Biotoxins conducted an interlaboratory exercise to extend AOAC Official Method 2005.06 validation for dc-GTX2,3 and to compile precision data for several STX-group toxins. This paper reports the study design and the results obtained. The performance characteristics for dc-GTX2,3 (intralaboratory and interlaboratory precision, recovery, and theoretical quantification limit) were evaluated. The mean recoveries obtained for dc-GTX2,3 were, in general, low (53.1-58.6%). The RSD for reproducibility (RSD(r)%) for dc-GTX2,3 in all samples ranged from 28.2 to 45.7%, and HorRat values ranged from 1.5 to 2.8. The article also describes a hydrolysis protocol to convert GTX6 to NEO, which has been proven to be useful for the quantification of GTX6 while the GTX6 standard is not available. The performance of the participant laboratories in the application of this method was compared with that obtained from the original collaborative study of the method. Intralaboratory and interlaboratory precision data for several STX-group toxins, including dc-NEO and GTX6, are reported here. This study can be useful for those laboratories determining STX-group toxins to fully implement AOAC Official Method 2005.06 for official paralytic shellfish poisoning control. However the overall quantitative performance obtained with the method was poor for certain toxins.

  10. An examination of the hexokinase method for serum glucose assay using external quality assessment data.

    PubMed

    Westwood, A; Bullock, D G; Whitehead, T P

    1986-01-01

    Hexokinase methods for serum glucose assay appeared to give slightly but consistently higher inter-laboratory coefficients of variation than all methods combined in the UK External Quality Assessment Scheme; their performance over a two-year period was therefore compared with that for three groups of glucose oxidase methods. This assessment showed no intrinsic inferiority in the hexokinase method. The greater variation may be due to the more heterogeneous group of instruments, particularly discrete analysers, on which the method is used. The Beckman Glucose Analyzer and Astra group (using a glucose oxidase method) showed the least inter-laboratory variability but also the lowest mean value. No comment is offered on the absolute accuracy of any of the methods.

  11. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples: T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents) and Hg-27 (Mercury) distributed in September 1998

    USGS Publications Warehouse

    Farrar, Jerry W.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples -- T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents), and Hg- 27 (mercury) -- which were distributed in September 1998 to 162 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  12. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1993 : T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for eight standard reference samples--T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)--that were distributed in October 1993 to 158 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 145 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the eight reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the eight standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  13. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1994 : T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength) and Hg-19 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1995-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 7 standard reference samples--T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength), and Hg-19 (mercury). The samples were distributed in October 1994 to 131 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 121 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  14. Development and Interlaboratory Study of a Liquid Chromatography Tandem Mass Spectrometric Methodfor the Determination of Multiple Mycotoxins inCereals Using Stable Isotope Dilution.

    PubMed

    Ye, Jin; Wu, Yu; Guo, Qilei; Lu, Meiling; Wang, Songshan; Xin, Yuanyuan; Xie, Gang; Zhang, Yan; Mariappan, Meena; Wang, Songxue

    2018-05-01

    An efficient, rapid, accurate, and cost-effective method based on stable isotope dilution and LC tandem MS was developed for the determination of multimycotoxins in cereals. The samples were extracted using acetonitrile-water-acetic acid (70 + 29 + 1, v/v/v), followed by dilution and centrifugation without any further cleanup. The mycotoxins were separated on a C18 column. Interference due to matrix effects was efficiently compensated for with [13C]-labeled stable isotope internal standards. The method demonstrated excellent linear relations, with regression coefficients above 0.999. Spiked recoveries at three different concentrations ranged from 80.9 to 115.9%, and RSDs were below 14% for all mycotoxins. The trueness of the method was also verified by participating in two proficiency tests, and satisfactory z-scores (|z| < 1.1) were obtained. In addition, an international interlaboratory study was organized to evaluate the methods. Eight laboratories characterized recovery, repeatability, and reproducibility studies in wheat, maize, and barley. The interlaboratory results were analyzed according to ISO 5725-2. Cochran and Grubbs tests were used to remove outliers. The mean recoveries of all 16 mycotoxins ranged from 87 to 111%. Repeatability, reproducibility, and Horwitz ratio values were 3.5-16.2, 5.4-33.6, and 0.16-1.65%, respectively. The results demonstrate that the method is reliable to determine multimycotoxins in cereals.

  15. Recent Advances in Targeted and Untargeted Metabolomics by NMR and MS/NMR Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingol, Kerem

    Metabolomics has made significant progress in multiple fronts in the last 18 months. This minireview aimed to give an overview of these advancements in the light of their contribution to targeted and untargeted metabolomics. New computational approaches have emerged to overcome manual absolute quantitation step of metabolites in 1D 1H NMR spectra. This provides more consistency between inter-laboratory comparisons. Integration of 2D NMR metabolomics databases under a unified web server allowed very accurate identification of the metabolites that have been catalogued in these databases. For the remaining uncatalogued and unknown metabolites, new cheminformatics approaches have been developed by combining NMRmore » and mass spectrometry. These hybrid NMR/MS approaches accelerated the identification of unknowns in untargeted studies, and now they are allowing to profile ever larger number of metabolites in application studies.« less

  16. System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

    NASA Technical Reports Server (NTRS)

    Kim, Hyun-Jung; Skuza, Jonathan R.; Park, Yeonjoon; King, Glen C.; Choi, Sang H.; Nagavalli, Anita

    2012-01-01

    The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

  17. Levels of exposure from drinking water.

    PubMed

    van Dijk-Looijaard, A M; van Genderen, J

    2000-01-01

    The relative exposure from drinking water is generally small, although there is a lack of information on total daily intake of individual organic micropollutants. There are, however, a few exceptions. Materials used in domestic distribution systems (lead, copper and plastics) may cause a deterioration of the water quality, especially in stagnant water. The relative exposure to the related compounds may increase considerably. Monitoring data from the tap (with defined sampling techniques) are needed. Also, disinfection/oxidation by-products (bromate, trihalomethanes) can be present in drinking water in considerable amounts and the relative exposure from drinking water may even approach 100%. Especially for volatile organic micropollutants, exposure routes from drinking water other than ingestion must be taken into account (inhalation, percutaneous uptake). When there is a need for detection of substances at very low levels it is important that the measurements are reliable. International interlaboratory comparisons for organic micropollutants are lacking at the moment.

  18. Enabling reliability assessments of pre-commercial perovskite photovoltaics with lessons learned from industrial standards

    NASA Astrophysics Data System (ADS)

    Snaith, Henry J.; Hacke, Peter

    2018-06-01

    Photovoltaic modules are expected to operate in the field for more than 25 years, so reliability assessment is critical for the commercialization of new photovoltaic technologies. In early development stages, understanding and addressing the device degradation mechanisms are the priorities. However, any technology targeting large-scale deployment must eventually pass industry-standard qualification tests and undergo reliability testing to validate the module lifetime. In this Perspective, we review the methodologies used to assess the reliability of established photovoltaics technologies and to develop standardized qualification tests. We present the stress factors and stress levels for degradation mechanisms currently identified in pre-commercial perovskite devices, along with engineering concepts for mitigation of those degradation modes. Recommendations for complete and transparent reporting of stability tests are given, to facilitate future inter-laboratory comparisons and to further the understanding of field-relevant degradation mechanisms, which will benefit the development of accelerated stress tests.

  19. Authentication of Closely Related Fish and Derived Fish Products Using Tandem Mass Spectrometry and Spectral Library Matching.

    PubMed

    Nessen, Merel A; van der Zwaan, Dennis J; Grevers, Sander; Dalebout, Hans; Staats, Martijn; Kok, Esther; Palmblad, Magnus

    2016-05-11

    Proteomics methodology has seen increased application in food authentication, including tandem mass spectrometry of targeted species-specific peptides in raw, processed, or mixed food products. We have previously described an alternative principle that uses untargeted data acquisition and spectral library matching, essentially spectral counting, to compare and identify samples without the need for genomic sequence information in food species populations. Here, we present an interlaboratory comparison demonstrating how a method based on this principle performs in a realistic context. We also increasingly challenge the method by using data from different types of mass spectrometers, by trying to distinguish closely related and commercially important flatfish, and by analyzing heavily contaminated samples. The method was found to be robust in different laboratories, and 94-97% of the analyzed samples were correctly identified, including all processed and contaminated samples.

  20. Distribution and sources of polyfluoroalkyl substances (PFAS) in the River Rhine watershed.

    PubMed

    Möller, Axel; Ahrens, Lutz; Surm, Renate; Westerveld, Joke; van der Wielen, Frans; Ebinghaus, Ralf; de Voogt, Pim

    2010-10-01

    The concentration profile of 40 polyfluoroalkyl substances (PFAS) in surface water along the River Rhine watershed from the Lake Constance to the North Sea was investigated. The aim of the study was to investigate the influence of point as well as diffuse sources, to estimate fluxes of PFAS into the North Sea and to identify replacement compounds of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). In addition, an interlaboratory comparison of the method performance was conducted. The PFAS pattern was dominated by perfluorobutane sulfonate (PFBS) and perfluorobutanoic acid (PFBA) with concentrations up to 181 ng/L and 335 ng/L, respectively, which originated from industrial point sources. Fluxes of SigmaPFAS were estimated to be approximately 6 tonnes/year which is much higher than previous estimations. Both, the River Rhine and the River Scheldt, seem to act as important sources of PFAS into the North Sea. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  1. [Study of continuous quality improvement for clinical laboratory processes via the platform of Hospital Group].

    PubMed

    Song, Wenqi; Shen, Ying; Peng, Xiaoxia; Tian, Jian; Wang, Hui; Xu, Lili; Nie, Xiaolu; Ni, Xin

    2015-05-26

    The program of continuous quality improvement in clinical laboratory processes for complete blood count (CBC) was launched via the platform of Beijing Children's Hospital Group in order to improve the quality of pediatric clinical laboratories. Fifteen children's hospitals of Beijing Children's Hospital group were investigated using the method of Chinese adapted continuous quality improvement with PDCA (Plan-Do-Check-Action). The questionnaire survey and inter-laboratory comparison was conducted to find the existing problems, to analyze reasons, to set forth quality targets and to put them into practice. Then, targeted training was conducted to 15 children's hospitals and the second questionnaire survey, self examinations by the clinical laboratories was performed. At the same time, the Group's online internal quality control platform was established. Overall effects of the program were evaluated so that lay a foundation for the next stage of PDCA. Both quality of control system documents and CBC internal quality control scheme for all of clinical laboratories were improved through this program. In addition, standardization of performance verification was also improved, especially with the comparable verification rate of precision and internal laboratory results up to 100%. In terms of instrument calibration and mandatory diagnostic rates, only three out of the 15 hospitals (20%) failed to pass muster in 2014 from 46.67% (seven out of the 15 hospitals) in 2013. The abnormal data of intraday precision variance coefficients of the five CBC indicator parameters (WBC, RBC, Hb, Plt and Hct) of all the 15 laboratories accounted for 1.2% (2/165) in 2014, a marked decrease from 9.6% (14/145) in 2013. While the number of the hospitals using only one horizontal quality control object for daily quality control has dropped to three from five. The 15 hospitals organized a total of 263 times of training in 2014 from 101 times in 2013, up 160%. The quality improvement program for the clinical laboratories launched via the Hospital Group platform can promote the joint development of the pediatric clinical laboratory discipline of all the member hospitals with remarkable improvement results, and the experience is recommendable for further rollout.

  2. Interlaboratory quality control of total HIV-1 DNA load measurement for multicenter reservoir studies.

    PubMed

    Gantner, Pierre; Mélard, Adeline; Damond, Florence; Delaugerre, Constance; Dina, Julia; Gueudin, Marie; Maillard, Anne; Sauné, Karine; Rodallec, Audrey; Tuaillon, Edouard; Plantier, Jean-Christophe; Rouzioux, Christine; Avettand-Fenoel, Véronique

    2017-11-01

    Viral reservoirs represent an important barrier to HIV cure. Accurate markers of HIV reservoirs are needed to develop multicenter studies. The aim of this multicenter quality control (QC) was to evaluate the inter-laboratory reproducibility of total HIV-1-DNA quantification. Ten laboratories of the ANRS-AC11 working group participated by quantifying HIV-DNA with a real-time qPCR assay (Biocentric) in four samples (QCMD). Good reproducibility was found between laboratories (standard deviation ≤ 0.2 log 10 copies/10 6 PBMC) for the three positive QC that were correctly classified by each laboratory (QC1

  3. External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 2002-03

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Latysh, Natalie E.; Burke, Kevin P.

    2005-01-01

    Six external quality-assurance programs were operated by the U.S. Geological Survey (USGS) External Quality-Assurance (QA) Project for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) from 2002 through 2003. Each program measured specific components of the overall error inherent in NADP/NTN wet-deposition measurements. The intersite-comparison program assessed the variability and bias of pH and specific conductance determinations made by NADP/NTN site operators twice per year with respect to accuracy goals. The percentage of site operators that met the pH accuracy goals decreased from 92.0 percent in spring 2002 to 86.3 percent in spring 2003. In these same four intersite-comparison studies, the percentage of site operators that met the accuracy goals for specific conductance ranged from 94.4 to 97.5 percent. The blind-audit program and the sample-handling evaluation (SHE) program evaluated the effects of routine sample handling, processing, and shipping on the chemistry of weekly NADP/NTN samples. The blind-audit program data indicated that the variability introduced by sample handling might be environmentally significant to data users for sodium, potassium, chloride, and hydrogen ion concentrations during 2002. In 2003, the blind-audit program was modified and replaced by the SHE program. The SHE program was designed to control the effects of laboratory-analysis variability. The 2003 SHE data had less overall variability than the 2002 blind-audit data. The SHE data indicated that sample handling buffers the pH of the precipitation samples and, in turn, results in slightly lower conductivity. Otherwise, the SHE data provided error estimates that were not environmentally significant to data users. The field-audit program was designed to evaluate the effects of onsite exposure, sample handling, and shipping on the chemistry of NADP/NTN precipitation samples. Field-audit results indicated that exposure of NADP/NTN wet-deposition samples to onsite conditions tended to neutralize the acidity of the samples by less than 1.0 microequivalent per liter. Onsite exposure of the sampling bucket appeared to slightly increase the concentration of most of the analytes but not to an extent that was environmentally significant to NADP data users. An interlaboratory-comparison program was used to estimate the analytical variability and bias of the NADP Central Analytical Laboratory (CAL) during 2002-03. Bias was identified in the CAL data for calcium, magnesium, sodium, potassium, ammonium, chloride, nitrate, sulfate, hydrogen ion, and specific conductance, but the absolute value of the bias was less than analytical minimum detection limits for all constituents except magnesium, nitrate, sulfate, and specific conductance. Control charts showed that CAL results were within statistical control approximately 90 percent of the time. Data for the analysis of ultrapure deionized-water samples indicated that CAL did not have problems with laboratory contamination. During 2002-03, the overall variability of data from the NADP/NTN precipitation-monitoring system was estimated using data from three collocated monitoring sites. Measurement differences of constituent concentration and deposition for paired samples from the collocated samplers were evaluated to compute error terms. The medians of the absolute percentage errors (MAEs) for the paired samples generally were larger for cations (approximately 8 to 50 percent) than for anions (approximately 3 to 33 percent). MAEs were approximately 16 to 30 percent for hydrogen-ion concentration, less than 10 percent for specific conductance, less than 5 percent for sample volume, and less than 8 percent for precipitation depth. The variability attributed to each component of the sample-collection and analysis processes, as estimated by USGS quality-assurance programs, varied among analytes. Laboratory analysis variability accounted for approximately 2 percent of the

  4. Multicenter comparison of levels of antibody to the Neisseria meningitidis group A capsular polysaccharide measured by using an enzyme-linked immunosorbent assay.

    PubMed Central

    Carlone, G M; Frasch, C E; Siber, G R; Quataert, S; Gheesling, L L; Turner, S H; Plikaytis, B D; Helsel, L O; DeWitt, W E; Bibb, W F

    1992-01-01

    There is no standard immunoassay for evaluating immune responses to meningococcal vaccines. We developed an enzyme-linked immunosorbent assay to measure total levels of antibody to Neisseria meningitidis group A capsular polysaccharide. Five laboratories measured the antibody levels in six paired pre- and postvaccination serum samples by using the enzyme-linked immunosorbent assay. Methylated human serum albumin was used to bind native group A polysaccharide to microtiter plate surfaces. The between-laboratory coefficients of variation for pre- and postvaccination sera had ranges of 31 to 91 and 17 to 31, respectively. The mean laboratory coefficients of variation for pre- and postvaccination sera, respectively, were 17 and 11 (Molecular Biology Laboratory, Centers for Disease Control), 12 and 15 (Immunodiagnostic Methods Laboratory, Centers for Disease Control), 22 and 19 (Dana-Farber Cancer Institute), 38 and 38 (Bacterial Polysaccharide Laboratory, U.S. Food and Drug Administration), and 11 and 10 (Praxis Biologics, Inc.). Standardization of this enzyme-linked immunosorbent assay should allow interlaboratory comparison of meningococcal vaccine immunogenicity, thus providing a laboratory-based assessment tool for evaluating meningococcal vaccines. PMID:1734048

  5. Creation of 0.10-cm-1 resolution quantitative infrared spectral libraries for gas samples

    NASA Astrophysics Data System (ADS)

    Sharpe, Steven W.; Sams, Robert L.; Johnson, Timothy J.; Chu, Pamela M.; Rhoderick, George C.; Guenther, Franklin R.

    2002-02-01

    The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are independently creating quantitative, approximately 0.10 cm-1 resolution, infrared spectral libraries of vapor phase compounds. The NIST library will consist of approximately 100 vapor phase spectra of volatile hazardous air pollutants (HAPs) and suspected greenhouse gases. The PNNL library will consist of approximately 400 vapor phase spectra associated with DOE's remediation mission. A critical part of creating and validating any quantitative work involves independent verification based on inter-laboratory comparisons. The two laboratories use significantly different sample preparation and handling techniques. NIST uses gravimetric dilution and a continuous flowing sample while PNNL uses partial pressure dilution and a static sample. Agreement is generally found to be within the statistical uncertainties of the Beer's law fit and less than 3 percent of the total integrated band areas for the 4 chemicals used in this comparison. There does appear to be a small systematic difference between the PNNL and NIST data, however. Possible sources of the systematic difference will be discussed as well as technical details concerning the sample preparation and the procedures for overcoming instrumental artifacts.

  6. Use of the Cultex® Radial Flow System as an in vitro exposure method to assess acute pulmonary toxicity of fine dusts and nanoparticles with special focus on the intra- and inter-laboratory reproducibility.

    PubMed

    Steinritz, Dirk; Möhle, Niklas; Pohl, Christine; Papritz, Mirko; Stenger, Bernhard; Schmidt, Annette; Kirkpatrick, Charles James; Thiermann, Horst; Vogel, Richard; Hoffmann, Sebastian; Aufderheide, Michaela

    2013-12-05

    Exposure of the respiratory tract to airborne particles (including metal-dusts and nano-particles) is considered as a serious health hazard. For a wide range of substances basic knowledge about the toxic properties and the underlying pathomechanisms is lacking or even completely missing. Legislation demands the toxicological characterization of all chemicals placed on the market until 2018 (REACH). As toxicological in vivo data are rare with regard to acute lung toxicity or exhibit distinct limitations (e.g. inter-species differences) and legislation claims the reduction of animal experiments in general ("3R" principle), profound in vitro models have to be established and characterized to meet these requirements. In this paper we characterize a recently introduced advanced in vitro exposure system (Cultex® RFS) showing a great similarity to the physiological in vivo exposure situation for the assessment of acute pulmonary toxicity of airborne materials. Using the Cultex® RFS, human lung epithelial cells (A549 cells) were exposed to different concentrations of airborne metal dusts (nano- and microscale particles) at the air-liquid-interface (ALI). Cell viability (WST-1 assay) as a parameter of toxicity was assessed 24h after exposure with special focus on the intra- and inter-laboratory (three independent laboratories) reproducibility. Our results show the general applicability of the Cultex® RFS with regard to the requirements of the ECVAM (European Centre for the Validation of Alternative Methods) principles on test validity underlining its robustness and stability. Intra- and inter-laboratory reproducibility can be considered as sufficient if predefined quality criteria are respected. Special attention must be paid to the pure air controls that turned out to be a critical parameter for a rational interpretation of the results. Our results are encouraging and future work is planned to improve the inter-laboratory reproducibility, to consolidate the results so far and to develop a valid prediction model. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples.

    PubMed

    van der Heeft, E; Dijkman, E; Baumann, R A; Hogendoorn, E A

    2000-05-19

    The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods the data agreed very well with the true values of the samples.

  8. An interlaboratory comparison of bone lead measurements via K-shell X-ray fluorescence spectrometry: validation against inductively coupled plasma mass spectrometry

    PubMed Central

    Bellis, David J.; Todd, Andrew C.

    2012-01-01

    109Cd-based K-shell X-ray fluorescence spectrometry (hereafter, for brevity, XRF) is used, often in epidemiological studies, to perform non-invasive, in vivo measurements of lead in bone. We conducted the first interlaboratory study of XRF via the circulation of nine goat tibiæ in which the mean lead value ranged from 4.0 µg g−1 to 55.3 µg g−1 bone mineral. The test tibiæ were subsequently analyzed via nitric acid digestion followed by lead determination by inductively coupled plasma mass spectrometry (ICP-MS) – along with certified reference materials for bone lead – thus providing measurement traceability to SI units. Analysis of dried bone for lead via nitric acid digestion and ICP-MS yields mass fraction data in units of µg g−1 dry weight. The mean bone lead value based on ICP-MS analysis ranged from 1.8 µg g−1 to 35.8 µg g−1 dry weight. For comparison purposes, XRF-measured Pb values (µg g−1 bone mineral) were converted into the ICP-MS-measured units (µg g−1dry weight bone) by multiplying the former by the average ash fraction from the nine tibiæ. Eight of the XRF systems did not yield a significant bias for any of the nine tibiæ; one system was biased for one of the tibiæ; two systems were biased for two tibiæ; one system was biased for four tibiæ; two systems (813-1 and 804-2) were biased for five tibiæ and one system (801-1) was biased for six of the nine tibiæ. Average bias for the systems (under those particular operating conditions) that were biased for the majority of samples ranged from −2.6 µg g−1 (−15.7%) to 5.1 µg g−1 (30.7%) dry weight bone. All participants now have the ICP-MS data, allowing any corrective actions deemed necessary to be implemented. The ICP-MS data, however, indicated that the lead mass fraction varied considerably with the sampling location within the tibiæ, to the extent of exceeding XRF variability for the higher lead values. Material heterogeneity is an unavoidable reality of measuring lead in bone. PMID:22468015

  9. Isochron burial dating of the Haslau terrace of the Danube (Vienna Basin) and interlaboratory comparison of sample preparation in Vienna and Budapest

    NASA Astrophysics Data System (ADS)

    Ruszkiczay-Rüdiger, Zsófia; Neuhuber, Stephanie; Decker, Kurt; Braucher, Régis; Fiebig, Marcus; Braun, Mihály; Lachner, Johannes; Aster Team

    2017-04-01

    In the Vienna Basin, terraces to the South of the Danube form a staircase with altitudes ranging between 25 and 130 m above current water level. The terrace system has been strongly dissected by faults related to the sinistral movement of the Vienna Basin Transform Fault System [1, 2]. Although each fault block displays a slightly different succession of terraces, fault-related vertical displacements south of the Danube have not yet been quantified. To better understand the Quaternary terrace sequence and its displacement along a fault segment south of the Danube, the isochron burial dating method [3] based on the 26Al and 10Be cosmogenic nuclide pair has been used on a terrace at Haslau an der Donau (˜40 m above river level). This terrace is locally the lowest of a staircase of a total of 6 different levels. Based on geomorphological mapping, its age was considered to be Middle Pleistocene [4]. The sample set consisted of several quartzite cobbles taken from two sedimentary units (5.5 m and 11.8 m depth) separated by an erosional hiatus of unknown duration. Six cobbles were selected for inter-laboratory comparison and processed at both the Cosmogenic Nuclide Sample Preparation Laboratory at Vienna and at Budapest [5]. AMS measurements were performed at the French national facility ASTER (CEREGE, Aix-en-Provence) and at the Vienna Environmental Research Accelerator (VERA). Initially, the obtained results show that the 10Be and 26Al concentrations calculated from the subsamples processed independently using different extraction schemes at both laboratories overlap within error for all subsamples but one, whose 26Al concentrations were significantly different. The low 26Al concentration measured in one Budapest sample probably resulted from Al having been trapped within the insoluble residues observed after evaporation to dryness. A modification of the sample processing allows overcoming this difficulty while treating for the following sample set. The results demonstrate that the laboratory background is safe for in-situ produced cosmogenic 10Be and 26Al extraction at both Vienna and Budapest laboratories and that the different geochemical digestion and purification schemes applied by the two laboratories for the extraction of 10Be and 26Al lead to similar results. A preliminary (not corrected) isochron burial age of ˜2.4 Ma was calculated for the higher sedimentary unit of the Haslau terrace on the basis of the slope of the isochron. This age is significantly older than the Middle Pleistocene age previously estimated. Further age determinations are nevertheless necessary to decide whether this preliminary age is accurate or not. Thanks to OTKA PD83610, OMAA 90öu17; LP2012-27/2012. INSU/CNRS, the ANR through the program "EQUIPEX Investissement d'Avenir" and IRD. References: [1] Decker et al., 2005. QSR 24, 307-322. [2] Salcher et al., 2012. Tectonics 31, 1-20. [3] Balco and Rovey, 2008. AJS 908, 1083-1114 [4] Fuchs and Grill, 1984. Geologische Karte von Wien und Umgebung (1:200.000) [5] http://www.geochem.hu/kozmogen/Lab_en.html

  10. High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air

    NASA Astrophysics Data System (ADS)

    Rella, C. W.; Chen, H.; Andrews, A. E.; Filges, A.; Gerbig, C.; Hatakka, J.; Karion, A.; Miles, N. L.; Richardson, S. J.; Steinbacher, M.; Sweeney, C.; Wastine, B.; Zellweger, C.

    2012-08-01

    Traditional techniques for measuring the mole fractions of greenhouse gas in the well-mixed atmosphere have required extremely dry sample gas streams (dew point < -25 °C) to achieve the inter-laboratory compatibility goals set forth by the Global Atmospheric Watch program of the World Meteorological Organization (WMO/GAW) for carbon dioxide (±0.1 ppm) and methane (±2 ppb). Drying the sample gas to low levels of water vapor can be expensive, time-consuming, and/or problematic, especially at remote sites where access is difficult. Recent advances in optical measurement techniques, in particular Cavity Ring Down Spectroscopy (CRDS), have led to the development of highly stable and precise greenhouse gas analyzers capable of highly accurate measurements of carbon dioxide, methane, and water vapor. Unlike many older technologies, which can suffer from significant uncorrected interference from water vapor, these instruments permit for the first time accurate and precise greenhouse gas measurements that can meet the WMO/GAW inter-laboratory compatibility goals without drying the sample gas. In this paper, we present laboratory methodology for empirically deriving the water vapor correction factors, and we summarize a series of in-situ validation experiments comparing the measurements in humid gas streams to well-characterized dry-gas measurements. By using the manufacturer-supplied correction factors, the dry-mole fraction measurements have been demonstrated to be well within the GAW compatibility goals up to at least 1% water vapor. By determining the correction factors for individual instruments once at the start of life, this range can be extended to at least 2% over the life of the instrument, and if the correction factors are determined periodically over time, the evidence suggests that this range can be extended above 4%.

  11. An Ibero-American inter-laboratory trial to evaluate serological tests for the detection of anti-Neospora caninum antibodies in cattle.

    PubMed

    Campero, Lucía M; Moreno-Gonzalo, Javier; Venturini, María C; Moré, Gastón; Dellarupe, Andrea; Rambeaud, Magdalena; Echaide, Ignacio E; Valentini, Beatriz; Campero, Carlos M; Moore, Dadín P; Cano, Dora B; Fort, Marcelo; Mota, Rinaldo A; Serrano-Martínez, Marcos E; Cruz-Vázquez, Carlos; Ortega-Mora, Luis M; Álvarez-García, Gema

    2018-01-01

    We carried out an inter-laboratory trial to compare the serological tests commonly used for the detection of specific Neospora caninum antibodies in cattle in Ibero-American countries. A total of eight laboratories participated from the following countries: Argentina (n = 4), Brazil (n = 1), Peru (n = 1), Mexico (n = 1), and Spain (n = 1). A blind panel of well-characterized cattle sera (n = 143) and sera representative of the target population (n = 351) was tested by seven in-house indirect fluorescent antibody tests (IFATs 1-7) and three enzyme-linked immunosorbent assays (ELISAs 1-3; two in-house and one commercial). Diagnostic performance of the serological tests was calculated and compared according to the following criteria: (1) the "Pre-test information," which uses previous epidemiological and serological data; (2) the "Majority of tests," which classifies a serum as positive or negative according to the results obtained by most tests evaluated. Unexpectedly, six tests showed either sensitivity (Se) or specificity (Sp) values lower than 90%. In contrast, the best tests in terms of Se, Sp, and area under the ROC curve (AUC) values were IFAT 1 and optimized ELISA 1 and ELISA 2. We evaluated a high number of IFATs, which are the most widely used tests in Ibero-America. The significant discordances observed among the tests regardless of the criteria employed hinder control programs and urge the use of a common test or with similar performances to either the optimized IFAT 1 and ELISAs 1 and 2.

  12. [The pilot program in Mexican clinical laboratories. I. The characterization of structure and productivity].

    PubMed

    de Gortari, E; Herrera, M; Loría, A; Terrés, A; González-Salayandia, M A; Hernández, M A

    1994-01-01

    To validate a questionnaire which evaluates the structure of clinical laboratories and to obtain information on its productivity. A group of 18 laboratories belonging to hospitals of second (N = 15) and third (N = 3) levels of health care. Fifteen participants belong to the public sector and three are first rate private institutions. They are located in the metropolitan area of Mexico City comprising the Federal District (N = 12) and the State of Mexico (N = 6). The questionnaire has 12 items which received a 0, 1/2 or 1 score. The maximum possible score for a perfect laboratory as well as for any question is 100. The questionnaire was filled during a visit to the participating hospitals by auditors of the agency of the Ministry of Health in charge of licensing laboratories at a national level. Information covering six months of work was obtained to calculate productivity using number of tests per worker per month. The global score of the 18 participants was 49. The private ones had the highest scores (79 to 96) which was to be expected as they were selected for their high technical and human resources. The five State laboratories had a score above the global mean, but only one of the Federal ones was in this situation. A high interlaboratory variability was observed, i.e. productivity in the highest rated was nine times larger than in the lowest rated. This finding suggests the presence of interlaboratory differences in the criteria used in the collection of productivity information. This short questionnaire can be used as a first approximation to identify structure deficiencies of the Mexican clinical laboratories.

  13. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 1)].

    PubMed

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Tonooka, Hiroyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.

  14. A 7-d toxicity test for marine pollutants using the Pacific mysid Mysidopsis intii. 2: Protocol evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harmon, V.L.; Langdon, C.J.

    1996-10-01

    The sensitivity of the Pacific coast mysid Mysidopsis intii to pollutants was compared in 7-d toxicity tests with that of the Gulf coast mysid M. bahia and the Pacific coast mysid Holmesimysis costata. Survival and growth responses of M. intii to zinc (maximum acceptable toxicant concentration [MATC] survival and growth, 152 {micro}g/L) were as sensitive as survival of both M. bahia (MATC survival, 152 {micro}g/L) and H. costata (MATC survival, 152 {micro}g/L). In contrast, the 7-d test for M. intii was less sensitive (MATC growth and survival, 4.99 mg/L) than the test for H. costata (MATC survival, 1.99 mg/L) whenmore » sodium dodecyl sulfate (SDS) was used as the toxicant. Interlaboratory evaluation of the 7-d test for M. intii exposed to SDS indicated that the test was reliable. The mean test results for the group of participating laboratories were not significantly different from those of a group of three in-house tests, indicating that shipping and handling did not affect mysid sensitivity to SDS. Mysid growth was not as sensitive to SDS as survival in the interlaboratory tests. Although there were significant differences in median lethal concentration (LC50) values among participating laboratories, coefficients of variation of LC50 and MATC survival values among laboratories were 10.3 and 37%, respectively. These coefficients were comparable to those reported for interlaboratory tests with H. costata.« less

  15. Absolute Isotopic Abundance Ratios and the Accuracy of Δ47 Measurements

    NASA Astrophysics Data System (ADS)

    Daeron, M.; Blamart, D.; Peral, M.; Affek, H. P.

    2016-12-01

    Conversion from raw IRMS data to clumped isotope anomalies in CO2 (Δ47) relies on four external parameters: the (13C/12C) ratio of VPDB, the (17O/16O) and (18O/16O) ratios of VSMOW (or VPDB-CO2), and the slope of the triple oxygen isotope line (λ). Here we investigate the influence that these isotopic parameters exert on measured Δ47 values, using real-world data corresponding to 7 months of measurements; simulations based on randomly generated data; precise comparisons between water-equilibrated CO2 samples and between carbonate standards believed to share quasi-identical Δ47 values; reprocessing of two carbonate calibration data sets with different slopes of Δ47 versus T. Using different sets of isotopic parameters generally produces systematic offsets as large as 0.04 ‰ in final Δ47 values. What's more, even using a single set of isotopic parameters can produce intra- and inter-laboratory discrepancies in final Δ47 values, if some of these parameters are inaccurate. Depending on the isotopic compositions of the standards used for conversion to "absolute" values, these errors should correlate strongly with either δ13C or δ18O, or more weakly with both. Based on measurements of samples expected to display identical Δ47 values, such as 25°C water-equilibrated CO2 with different carbon and oxygen isotope compositions, or high-temperature standards ETH-1 and ETH-2, we conclude that the isotopic parameters used so far in most clumped isotope studies produces large, systematic errors controlled by the relative bulk isotopic compositions of samples and standards, which should be one of the key factors responsible for current inter-laboratory discrepancies. By contrast, the isotopic parameters of Brand et al. [2010] appear to yield accurate Δ47 values regardless of bulk isotopic composition. References:Brand, Assonov and Coplen [2010] http://dx.doi.org/10.1351/PAC-REP-09-01-05

  16. Improved accuracy in high-temperature conversion elemental analyzer δ18O measurements of nitrogen-rich organics.

    PubMed

    Hunsinger, Glendon B; Stern, Libby A

    2012-03-15

    The use of high-temperature conversion (HTC) reduction systems interfaced with isotope ratio mass spectrometers for δ(18)O measurements of nitrogen-containing organic materials is complicated by isobaric interference from (14)N(16)O(+). This ion is produced in the ion source when N(2) reacts with trace oxygen shifting the m/z 30 baseline prior to elution of CO. We compared adaptations to a typical HTC system (TC/EA) to determine the best method to measure the δ(18)O values of nitrogen-rich organic substrates including: (1) 0.6 and 1.5 m 5 Å molecular sieve GC columns; (2) reduction of N(2) peak via He dilution; and (3) diversion of N(2) to waste via an automated four-port valve. These methods were applied to caffeine (IAEA-600), glycine, 4-nitroacetanilide, pentaerythritol tetranitrate (PETN) and cyclotrimethylene trinitramine (RDX), as well as pure and sodium azide-doped benzoic acid (IAEA-601) and sucrose (IAEA-CH6). The efficiency of N(2) production in the HTC interface was highly variable among these compounds. Both the longer column and the dilutor improved, but did not eliminate, the adverse effects of nitrogen. The diversion of N(2) adequately addressed the nitrogen-induced problems as indicated by: (1) consistent m/z 30 background offset between reference and sample CO for both N-free and N-rich materials; (2) production of the highest δ(18)O values; and (3) high correlation between the increase in the δ(18)O values relative to the GC-only measurements and the N(2) peak area. Additional validation would require N-rich oxygen isotope standards for inter-laboratory comparisons. Further, more stringent methodology may improve the poor inter-laboratory δ(18)O reproducibility of IAEA-600. Published in 2012 by John Wiley & Sons, Ltd.

  17. Inter-laboratory validation of an inexpensive streamlined method to measure inorganic arsenic in rice grain.

    PubMed

    Chaney, Rufus L; Green, Carrie E; Lehotay, Steven J

    2018-05-04

    With the establishment by CODEX of a 200 ng/g limit of inorganic arsenic (iAs) in polished rice grain, more analyses of iAs will be necessary to ensure compliance in regulatory and trade applications, to assess quality control in commercial rice production, and to conduct research involving iAs in rice crops. Although analytical methods using high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) have been demonstrated for full speciation of As, this expensive and time-consuming approach is excessive when regulations are based only on iAs. We report a streamlined sample preparation and analysis of iAs in powdered rice based on heated extraction with 0.28 M HNO 3 followed by hydride generation (HG) under control of acidity and other simple conditions. Analysis of iAs is then conducted using flow-injection HG and inexpensive ICP-atomic emission spectroscopy (AES) or other detection means. A key innovation compared with previous methods was to increase the acidity of the reagent solution with 4 M HCl (prior to reduction of As 5+ to As 3+ ), which minimized interferences from dimethylarsinic acid. An inter-laboratory method validation was conducted among 12 laboratories worldwide in the analysis of six shared blind duplicates and a NIST Standard Reference Material involving different types of rice and iAs levels. Also, four laboratories used the standard HPLC-ICP-MS method to analyze the samples. The results between the methods were not significantly different, and the Horwitz ratio averaged 0.52 for the new method, which meets official method validation criteria. Thus, the simpler, more versatile, and less expensive method may be used by laboratories for several purposes to accurately determine iAs in rice grain. Graphical abstract Comparison of iAs results from new and FDA methods.

  18. Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine

    PubMed Central

    Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J.; Weimann, Allan; Poulsen, Henrik E.; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D.; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B.; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T.; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J.; Santella, Regina M.; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen

    2013-01-01

    Abstract Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (rp 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391. PMID:23198723

  19. Performance Metrics for Liquid Chromatography-Tandem Mass Spectrometry Systems in Proteomics Analyses*

    PubMed Central

    Rudnick, Paul A.; Clauser, Karl R.; Kilpatrick, Lisa E.; Tchekhovskoi, Dmitrii V.; Neta, Pedatsur; Blonder, Nikša; Billheimer, Dean D.; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Ham, Amy-Joan L.; Jaffe, Jacob D.; Kinsinger, Christopher R.; Mesri, Mehdi; Neubert, Thomas A.; Schilling, Birgit; Tabb, David L.; Tegeler, Tony J.; Vega-Montoto, Lorenzo; Variyath, Asokan Mulayath; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Paulovich, Amanda G.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Tempst, Paul; Liebler, Daniel C.; Stein, Stephen E.

    2010-01-01

    A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications. PMID:19837981

  20. Determination of the acid value of instant noodles: interlaboratory study.

    PubMed

    Hakoda, Akiko; Sakaida, Kenichi; Suzuki, Tadanao; Yasui, Akemi

    2006-01-01

    An interlaboratory study was performed to evaluate the method for determining the acid value of instant noodles, based on the Japanese Agricultural Standard (JAS), with extraction of lipid using petroleum ether at a volume of 100 mL to the test portion of 25 g. Thirteen laboratories participated and analyzed 5 test samples as blind duplicates. Statistical treatment revealed that the repeatability (RSDr) of acid value was <6.5%, and the reproducibility (RSDR) of acid value was <9.6%. The HorRat values (RSDR/predicted RSDR) were 1.2-1.8, where the RSDR and the predicted RSDR were obtained in terms of free fatty acids in the noodles per unit weight, using the equation [acid value = percent free fatty acids (as oleic) x 1.99] and the extracted lipid contents. This method was shown to have acceptable precision by the present study.

  1. Interlaboratory study for nickel alloy 625 made by laser powder bed fusion to quantify mechanical property variability.

    PubMed

    Brown, Christopher U; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan

    2016-08-01

    Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser-powder-bed-fusion additive manufacturing machines. The tensile specimens were heat treated and tensile tests conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to 4 times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure.

  2. Bayesian Local Contamination Models for Multivariate Outliers

    PubMed Central

    Page, Garritt L.; Dunson, David B.

    2013-01-01

    In studies where data are generated from multiple locations or sources it is common for there to exist observations that are quite unlike the majority. Motivated by the application of establishing a reference value in an inter-laboratory setting when outlying labs are present, we propose a local contamination model that is able to accommodate unusual multivariate realizations in a flexible way. The proposed method models the process level of a hierarchical model using a mixture with a parametric component and a possibly nonparametric contamination. Much of the flexibility in the methodology is achieved by allowing varying random subsets of the elements in the lab-specific mean vectors to be allocated to the contamination component. Computational methods are developed and the methodology is compared to three other possible approaches using a simulation study. We apply the proposed method to a NIST/NOAA sponsored inter-laboratory study which motivated the methodological development. PMID:24363465

  3. Variances and uncertainties of the sample laboratory-to-laboratory variance (S(L)2) and standard deviation (S(L)) associated with an interlaboratory study.

    PubMed

    McClure, Foster D; Lee, Jung K

    2012-01-01

    The validation process for an analytical method usually employs an interlaboratory study conducted as a balanced completely randomized model involving a specified number of randomly chosen laboratories, each analyzing a specified number of randomly allocated replicates. For such studies, formulas to obtain approximate unbiased estimates of the variance and uncertainty of the sample laboratory-to-laboratory (lab-to-lab) STD (S(L)) have been developed primarily to account for the uncertainty of S(L) when there is a need to develop an uncertainty budget that includes the uncertainty of S(L). For the sake of completeness on this topic, formulas to estimate the variance and uncertainty of the sample lab-to-lab variance (S(L)2) were also developed. In some cases, it was necessary to derive the formulas based on an approximate distribution for S(L)2.

  4. Interlaboratory study for nickel alloy 625 made by laser powder bed fusion to quantify mechanical property variability

    PubMed Central

    Brown, Christopher U.; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan

    2017-01-01

    Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser-powder-bed-fusion additive manufacturing machines. The tensile specimens were heat treated and tensile tests conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to 4 times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure. PMID:28243032

  5. Quality assurance in RT-PCR-based BCR/ABL diagnostics--results of an interlaboratory test and a standardization approach.

    PubMed

    Burmeister, T; Maurer, J; Aivado, M; Elmaagacli, A H; Grünebach, F; Held, K R; Hess, G; Hochhaus, A; Höppner, W; Lentes, K U; Lübbert, M; Schäfer, K L; Schafhausen, P; Schmidt, C A; Schüler, F; Seeger, K; Seelig, R; Thiede, C; Viehmann, S; Weber, C; Wilhelm, S; Christmann, A; Clement, J H; Ebener, U; Enczmann, J; Leo, R; Schleuning, M; Schoch, R; Thiel, E

    2000-10-01

    Here we describe the results of an interlaboratory test for RT-PCR-based BCR/ABL analysis. The test was organized in two parts. The number of participating laboratories in the first and second part was 27 and 20, respectively. In the first part samples containing various concentrations of plasmids with the ela2, b2a2 or b3a2 BCR/ABL transcripts were analyzed by PCR. In the second part of the test, cell samples containing various concentrations of BCR/ABL-positive cells were analyzed by RT-PCR. Overall PCR sensitivity was sufficient in approximately 90% of the tests, but a significant number of false positive results were obtained. There were significant differences in sensitivity in the cell-based analysis between the various participants. The results are discussed, and proposals are made regarding the choice of primers, controls, conditions for RNA extraction and reverse transcription.

  6. Interlaboratory Study for Nickel Alloy 625 Made by Laser Powder Bed Fusion to Quantify Mechanical Property Variability

    NASA Astrophysics Data System (ADS)

    Brown, Christopher U.; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan

    2016-08-01

    Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser powder bed fusion-additive manufacturing machines. The tensile specimens were heat treated and tensile tests were conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to four times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure.

  7. Preparation and provisional certification of NBL Spectrographic Impurity Standards, CRM 123 (1-7) and 124 (1-7)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santoliquido, P.M.

    This report describes the design, production, and provisional certification of two new certified reference materials (CRMs): CRM No. 123 (1-7), U/sub 3/O/sub 8/ containing 18 trace elements, and CRM No. 124 (1-7), U/sub 3/O/sub 8/ containing 24 trace elements. The elements to be included and concentrations to be used were decided on the basis of information gathered from users of a previous CRM of this type, CRM No. 98 (1-7). The new CRMs were prepared by the addition of trace elements to high purity U/sub 3/O/sub 8/. Provisional certification was accomplished by an interlaboratory program in which four different laboratoriesmore » analyzed the materials by carrier distillation dc arc emission spectrography.« less

  8. Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum.

    PubMed

    Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H

    2012-01-01

    Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.

  9. External quality assessment program for detection of glucose-6-phosphate dehydrogenase deficiency in the Guangxi region.

    PubMed

    Tang, Juan; Zhou, Xiangyang; Liu, Xiaochun; Ning, Leping; Zhou, Weiya; He, Yi

    2017-09-01

    The aim of this study is to improve the quality of testing for glucose-6-phosphate dehydrogenase (G6PD) deficiency through evaluation and analysis of the laboratory tests for G6PD activity. External quality assessment (EQA) was carried out twice per year with five samples each from 2014 to 2016. Samples were used for quantitative and qualitative assays. Quantitative results were collected, qualitative results were determined with reference values, and information about methods, reagents and instruments from participating laboratories within the required time. Laboratory performance scores, coefficient of variation (CV), and the rates of false negative and positive results were calculated. As a result, a total of 2,834 cases of negative quality control (QC) samples and 2,451 cases of positive QC samples were assessed, where the rates of false negative and false positive results were 1.31% (37/2,834) and 1.34% (33/2,451), respectively. Quantitative results indicated an increasing trend in testing quality, which were consistent with conclusions based on the comparison of EQA full-score and acceptable ratio in six assessments. The 2nd assay in 2016 had the best full-score ratio of 68.9% (135/196) and best acceptable ratio of 84.2% (165/196). There was a decreasing trend in the average CV of six reagents produced in China, and the range of average CV increased to 14.6-23.6% in 2016. The average CV of low level and high level samples was 22.5% and 15.3%, respectively, demonstrating that samples with low G6PD activity have greater interlaboratory CV values. In conclusion, laboratories improved their testing quality and provided better diagnostic service for G6PD deficiency in areas with high incidence after participation in the EQA program in the Guangxi region.

  10. Multicenter Evaluation of Epidemiological Typing of Methicillin-Resistant Staphylococcus aureus Strains by Repetitive-Element PCR Analysis

    PubMed Central

    Deplano, Ariane; Schuermans, Annette; Van Eldere, Johan; Witte, Wolfgang; Meugnier, Hèléne; Etienne, Jerome; Grundmann, Hajo; Jonas, Daniel; Noordhoek, Gerda T.; Dijkstra, Jolanda; van Belkum, Alex; van Leeuwen, Willem; Tassios, Panayotis T.; Legakis, Nicholas J.; van der Zee, Anneke; Bergmans, Anneke; Blanc, Dominique S.; Tenover, Fred C.; Cookson, Barry C.; O'Neil, Gael; Struelens, Marc J.

    2000-01-01

    Rapid and efficient epidemiologic typing systems would be useful to monitor transmission of methicillin-resistant Staphylococcus aureus (MRSA) at both local and interregional levels. To evaluate the intralaboratory performance and interlaboratory reproducibility of three recently developed repeat-element PCR (rep-PCR) methods for the typing of MRSA, 50 MRSA strains characterized by pulsed-field gel electrophoresis (PFGE) (SmaI) analysis and epidemiological data were blindly typed by inter-IS256, 16S-23S ribosomal DNA (rDNA), and MP3 PCR in 12 laboratories in eight countries using standard reagents and protocols. Performance of typing was defined by reproducibility (R), discriminatory power (D), and agreement with PFGE analysis. Interlaboratory reproducibility of pattern and type classification was assessed visually and using gel analysis software. Each typing method showed a different performance level in each center. In the center performing best with each method, inter-IS256 PCR typing achieved R = 100% and D = 100%; 16S-23S rDNA PCR, R = 100% and D = 82%; and MP3 PCR, R = 80% and D = 83%. Concordance between rep-PCR type and PFGE type ranged by center: 70 to 90% for inter-IS256 PCR, 44 to 57% for 16S-23S rDNA PCR, and 53 to 54% for MP3 PCR analysis. In conclusion, the performance of inter-IS256 PCR typing was similar to that of PFGE analysis in some but not all centers, whereas other rep-PCR protocols showed lower discrimination and intralaboratory reproducibility. None of these assays, however, was sufficiently reproducible for interlaboratory exchange of data. PMID:11015358

  11. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    NASA Technical Reports Server (NTRS)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  12. Urinary biomarkers of smokers’ exposure to tobacco smoke constituents in tobacco products assessment: a fit for purpose approach

    PubMed Central

    Gregg, Evan O.; Minet, Emmanuel

    2013-01-01

    There are established guidelines for bioanalytical assay validation and qualification of biomarkers. In this review, they were applied to a panel of urinary biomarkers of tobacco smoke exposure as part of a “fit for purpose” approach to the assessment of smoke constituents exposure in groups of tobacco product smokers. Clinical studies have allowed the identification of a group of tobacco exposure biomarkers demonstrating a good doseresponse relationship whilst others such as dihydroxybutyl mercapturic acid and 2-carboxy-1-methylethylmercapturic acid – did not reproducibly discriminate smokers and non-smokers. Furthermore, there are currently no agreed common reference standards to measure absolute concentrations and few inter-laboratory trials have been performed to establish consensus values for interim standards. Thus, we also discuss in this review additional requirements for the generation of robust data on urinary biomarkers, including toxicant metabolism and disposition, method validation and qualification for use in tobacco products comparison studies. PMID:23902266

  13. Two New Reference Materials Based on Tobacco Leaves: Certification for over a Dozen of Toxic and Essential Elements

    PubMed Central

    Samczyński, Zbigniew; Dybczyński, Rajmund S.; Polkowska-Motrenko, Halina; Chajduk, Ewelina; Pyszynska, Marta; Danko, Bożena; Czerska, Elżbieta; Kulisa, Krzysztof; Doner, Katarzyna; Kalbarczyk, Paweł

    2012-01-01

    The preparation, certification, and characterization of two new biological certified reference materials for inorganic trace analysis have been presented. They are based on two different varieties of tobacco leaves, namely, Oriental Basma Tobacco Leaves (INCT-OBTL-5), grown in Greece, and Polish Virginia Tobacco Leaves (INCT-PVTL-6), grown in Poland. Certification of the materials was based on the statistical evaluation of results obtained in a worldwide interlaboratory comparison, in which 87 laboratories from 18 countries participated, providing 2568 laboratory averages on nearly 80 elements. It was possible to establish the certified values of concentration for many elements in the new materials, that is, 37 in INCT-OBTL-5 and 36 in INCT-PVTL-6, including several toxic ones like As, Cd, Hg, Pb, and so forth. The share and the role of instrumental analytical techniques used in the process of certification of the new CRMs are discussed. PMID:22536124

  14. Determination of methylmercury in marine biota samples with advanced mercury analyzer: method validation.

    PubMed

    Azemard, Sabine; Vassileva, Emilia

    2015-06-01

    In this paper, we present a simple, fast and cost-effective method for determination of methyl mercury (MeHg) in marine samples. All important parameters influencing the sample preparation process were investigated and optimized. Full validation of the method was performed in accordance to the ISO-17025 (ISO/IEC, 2005) and Eurachem guidelines. Blanks, selectivity, working range (0.09-3.0ng), recovery (92-108%), intermediate precision (1.7-4.5%), traceability, limit of detection (0.009ng), limit of quantification (0.045ng) and expanded uncertainty (15%, k=2) were assessed. Estimation of the uncertainty contribution of each parameter and the demonstration of traceability of measurement results was provided as well. Furthermore, the selectivity of the method was studied by analyzing the same sample extracts by advanced mercury analyzer (AMA) and gas chromatography-atomic fluorescence spectrometry (GC-AFS). Additional validation of the proposed procedure was effectuated by participation in the IAEA-461 worldwide inter-laboratory comparison exercises. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. The discriminatory power of ribotyping as automatable technique for differentiation of bacteria.

    PubMed

    Schumann, Peter; Pukall, Rüdiger

    2013-09-01

    Since the introduction of ribonucleic acid gene restriction patterns as taxonomic tools in 1986, ribotyping has become an established method for systematics, epidemiological, ecological and population studies of microorganisms. In the last 25 years, several modifications have improved the convenience, reproducibility and turn-around time of this technique. The technological development culminated in the automation of ribotyping which allowed for high-throughput applications e.g. in the quality control of food production, pharmaceutical industry and culture collections. The capability of the fully automated RiboPrinter(®) System for the differentiation of bacteria below the species level is compared with the discriminatory power of traditional ribotyping, of molecular fingerprint techniques like PFGE, MLST and MLVA as well as of MALDI-TOF mass spectrometry. While automated RiboPrinting is advantageous with respect to standardization, ease and speed, PCR ribotyping has proved being a highly discriminatory, flexible, robust and cost-efficient routine technique which makes inter-laboratory comparison and build of ribotype databases possible, too. Copyright © 2013 Elsevier GmbH. All rights reserved.

  16. A comparison of the MeltPro® HPV Test with the Cobas® HPV Test for detecting and genotyping 14 high-risk human papillomavirus types.

    PubMed

    Tang, Zhiteng; Xu, Ye; Song, Najie; Zou, Dongqing; Liao, Yiqun; Li, Qingge; Pan, Chao

    2018-03-01

    The clinical performance of the newly developed MeltPro ® HPV Test, based on multicolor melting curve analysis, was evaluated and compared with the commercially available Cobas ® HPV Test for detection of HPV and genotyping of HPV-16 and HPV-18. A total of 1647 cervical samples were analyzed with both tests. The agreement values were 96.2% for HPV detection, 99.6% for HPV-16 identification, and 99.7% for HPV-18 identification. All genotyping results from MeltPro ® HPV Test showed that HPV-52, HPV-58, and HPV-16 were the most common types in this study. Intra-laboratory reproducibility studies showed 97.8% agreement while inter-laboratory reproducibility studies showed 96.9% agreement for the MeltPro ® HPV Test. The MeltPro ® HPV Test and Cobas ® HPV Test are highly correlative and are useful for monitoring HPV infection.

  17. Measurements of gamma (γ)-emitting radionuclides with a high-purity germanium detector: the methods and reliability of our environmental assessments on the Fukushima 1 Nuclear Power Plant accident.

    PubMed

    Mimura, Tetsuro; Mimura, Mari; Komiyama, Chiyo; Miyamoto, Masaaki; Kitamura, Akira

    2014-01-01

    The severe accident of Fukushima 1 Nuclear Power Plant due to the Tohoku Region Pacific Coast Earthquake in 11 March 2011 caused wide contamination and pollution by radionuclides in Fukushima and surrounding prefectures. In the current JPR symposium, a group of plant scientists attempted to examine the impact of the radioactive contamination on wild and cultivated plants. Measurements of gamma (γ) radiation from radionuclides in "Fukushima samples", which we called and collected from natural and agricultural areas in Fukushima prefecture were mostly done with a high-purity Ge detector in the Graduate School of Maritime Sciences, Kobe University. In this technical note, we describe the methods of sample preparation and measurements of radioactivity of the samples and discuss the reliability of our data in regards to the International Atomic Energy Agency (IAEA) Interlaboratory comparisons and proficiency test (IAEA proficiency test).

  18. Evaluation of Calibration Laboratories Performance

    NASA Astrophysics Data System (ADS)

    Filipe, Eduarda

    2011-12-01

    One of the main goals of interlaboratory comparisons (ILCs) is the evaluation of the laboratories performance for the routine calibrations they perform for the clients. In the frame of Accreditation of Laboratories, the national accreditation boards (NABs) in collaboration with the national metrology institutes (NMIs) organize the ILCs needed to comply with the requirements of the international accreditation organizations. In order that an ILC is a reliable tool for a laboratory to validate its best measurement capability (BMC), it is needed that the NMI (reference laboratory) provides a better traveling standard—in terms of accuracy class or uncertainty—than the laboratories BMCs. Although this is the general situation, there are cases where the NABs ask the NMIs to evaluate the performance of the accredited laboratories when calibrating industrial measuring instruments. The aim of this article is to discuss the existing approaches for the evaluation of ILCs and propose a basis for the validation of the laboratories measurement capabilities. An example is drafted with the evaluation of the results of mercury-in-glass thermometers ILC with 12 participant laboratories.

  19. Quality control assurance of strontium-90 in foodstuffs by LSC.

    PubMed

    Lopes, I; Mourato, A; Abrantes, J; Carvalhal, G; Madruga, M J; Reis, M

    2014-11-01

    A method based on the separation of Sr-90 by extraction chromatography and beta determination by Liquid Scintillation Counting (LSC) technique was used for strontium analysis in food samples. The methodology consisted in prior sample treatment (drying and incineration) followed by radiochemical separation of Sr-90 by extraction chromatography, using the Sr-resin. The chemical yield was determined by gravimetric method, adding stable strontium to the matrix. Beta activity (Sr-90/Y-90) was determined using a low background liquid scintillation spectrometer (Tri-Carb 3170 TR/SL, Packard). The accuracy and the precision of the method, was performed previously through recovery trials with Sr-90 spiked samples, using the same type of matrices (milk, complete meals, meat and vegetables). A reference material (IAEA_321) was now used to measure the accuracy of the procedure. Participation in interlaboratory comparison exercises was also performed in order to establish an external control on the measurements and to ensure the adequacy of the method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. NIST Efforts to Quality-Assure Gunpowder Measurements

    NASA Technical Reports Server (NTRS)

    MacCrehan, William A.; Reardon, Michelle R.

    2000-01-01

    In the past few years, the National Institute for Standards and Technology (NIST) has been promoting the idea of quantitatively determining the additives in smokeless gunpowder using micellar capillary electrophoresis as a means of investigating the criminal use of hand guns and pipe bombs. As a part of this effort, we have evaluated both supercritical fluid and ultrasonic solvent extractions for the quantitative recovery of nitroglycerin (NG), diphenylamine (DPA), N-nitrosodiphenylamine (NnDPA), and ethyl centralite (EC) from gunpowder. Recoveries were evaluated by repeat extraction and matrix spiking experiments. The final extraction protocol provides greater than 95 percent recoveries. To help other researches validate their own analytical method for additive determinations, NIST is exploring the development of a standard reference material, Additives in Smokeless Gunpowder. The evaluated method is being applied to two double-base (NG-containing) powders, one stabilized with diphenylamine and the other with ethyl centralite. As part of this reference material development effort, we are conducting an interlaboratory comparison exercise among the forensic and military gunpowder measurement community.

  1. Total arsenic, lead, cadmium, copper, and zinc in some salt rivers in the northern Andes of Antofagasta, Chile.

    PubMed

    Queirolo, F; Stegen, S; Mondaca, J; Cortés, R; Rojas, R; Contreras, C; Munoz, L; Schwuger, M J; Ostapczuk, P

    2000-06-08

    The pre-Andes water in the region of Antofagasta is the main drinking and irrigation water source for approximately 3000 Atacameña (indigenous) people. The concentration for soluble elements (filtration in field through a 0.45-microm filter) was: Cd < 0.1 ng/ml; Pb < 0.5 ng/ml; and Zn and Cu between 1 and 10 ng/ml. In particulate material the concentrations were: for Cd < 0.1 ng/ml; for Pb < 0.3 ng/ml; and for Zn and Cu less than 1 ng/ml. The total content of these elements is far below the international recommendations (WHO) and the national standards (N. Ch. 1333 mod. 1987 and 409-1 of 1984). On the other hand, in some rivers a very high arsenic concentration was found (up to 3000 ng/ml) which exceed more than 50 times the national standard. In order to verify the analytical results, inter-laboratory and comparison with different determination methods have been done.

  2. Extrapolating Accelerated UV Weathering Data: Perspective From PVQAT Task Group 5 (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.; Annigoni, E.; Ballion, A.

    2015-02-01

    Taskgroup 5 (TG5) is concerned with a accelerated aging standard incorporating factors including ultraviolet radiation, temperature, and moisture. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for the TG5 interlaboratory study being directed out of the USA. Qualitative preliminary data from the experiment is presented. To date, the encapsulation transmittance experiment has: replicated behaviors of fielded materials (including specimen location- and formulation additive-specific discoloration); demonstrated coupling between UV aging and temperature; demonstrated that degradation in EVA results frommore » UV- aging; and obtained good qualitative comparison between Xe and UVA-340 sources for EVA. To date, the encapsulation adhesion experiment (using the compressive shear test to quantify strength of attachment) has demonstrated that attachment strength can decrease drastically (>50%) with age; however, early results suggest significant factor (UV, T, RH) dependence. Much remains to be learned about adhesion.« less

  3. Performance evaluation of elemental analysis/isotope ratio mass spectrometry methods for the determination of the D/H ratio in tetramethylurea and other compounds--results of a laboratory inter-comparison.

    PubMed

    Bréas, Olivier; Thomas, Freddy; Zeleny, Reinhard; Calderone, Giovanni; Jamin, Eric; Guillou, Claude

    2007-01-01

    Tetramethylurea (TMU) with a certified D/H ratio is the internal standard for Site-specific Natural Isotope Fractionation measured by Nuclear Magnetic Resonance (SNIF-NMR) analysis of wine ethanol for detection of possible adulterations (Commission Regulation 2676/90). A new batch of a TMU certified reference material (CRM) is currently being prepared. Whereas SNIF-NMR has been employed up to now, Elemental Analysis/Isotope Ratio Mass Spectrometry ((2)H-EA-IRMS) was envisaged as the method of choice for value assignment of the new CRM, as more precise (better repeatable) data might be obtained, resulting in lower uncertainty of the certified value. In order to evaluate the accuracy and intra- and inter-laboratory reproducibility of (2)H-EA-IRMS methods, a laboratory inter-comparison was carried out by analysing TMU and other organic compounds, as well as some waters. The results revealed that experienced laboratories are capable of generating robust and well comparable data, which highlights the emerging potential of IRMS in food authenticity testing. However, a systematic bias between IRMS and SNIF-NMR reference data was observed for TMU; this lack of data consistency rules out the (2)H-IRMS technique for the characterisation measurement of the new TMU CRM.

  4. Validation of a simple, manual urinary iodine method for estimating the prevalence of iodine-deficiency disorders, and interlaboratory comparison with other methods.

    PubMed

    May, S L; May, W A; Bourdoux, P P; Pino, S; Sullivan, K M; Maberly, G F

    1997-05-01

    The measurement of urinary iodine in population-based surveys provides a biological indicator of the severity of iodine-deficiency disorders. We describe the steps performed to validate a simple, inexpensive, manual urinary iodine acid digestion method, and compare the results using this method with those of other urinary iodine methods. Initially, basic performance characteristics were evaluated: the average recovery of added iodine was 100.4 +/- 8.7% (mean +/- SD), within-assay precision (CV) over the assay range 0-0.95 mumol/L (0-12 micrograms/dL) was < 6%, between-assay precision over the same range was < 12%, and assay sensitivity was 0.05 mumol/L (0.6 microgram/dL). There were no apparent effects on the method by thiocyanate, a known interfering substance. In a comparison with five other methods performed in four different laboratories, samples were collected to test the method performance over a wide range of urinary iodine values (0.04-3.7 mumol/L, or 0.5-47 micrograms/dL). There was a high correlation between all methods and the interpretation of the results was consistent. We conclude that the simple, manual acid digestion method is suitable for urinary iodine analysis.

  5. Differentiating gold nanorod samples using particle size and shape distributions from transmission electron microscope images

    NASA Astrophysics Data System (ADS)

    Grulke, Eric A.; Wu, Xiaochun; Ji, Yinglu; Buhr, Egbert; Yamamoto, Kazuhiro; Song, Nam Woong; Stefaniak, Aleksandr B.; Schwegler-Berry, Diane; Burchett, Woodrow W.; Lambert, Joshua; Stromberg, Arnold J.

    2018-04-01

    Size and shape distributions of gold nanorod samples are critical to their physico-chemical properties, especially their longitudinal surface plasmon resonance. This interlaboratory comparison study developed methods for measuring and evaluating size and shape distributions for gold nanorod samples using transmission electron microscopy (TEM) images. The objective was to determine whether two different samples, which had different performance attributes in their application, were different with respect to their size and/or shape descriptor distributions. Touching particles in the captured images were identified using a ruggedness shape descriptor. Nanorods could be distinguished from nanocubes using an elongational shape descriptor. A non-parametric statistical test showed that cumulative distributions of an elongational shape descriptor, that is, the aspect ratio, were statistically different between the two samples for all laboratories. While the scale parameters of size and shape distributions were similar for both samples, the width parameters of size and shape distributions were statistically different. This protocol fulfills an important need for a standardized approach to measure gold nanorod size and shape distributions for applications in which quantitative measurements and comparisons are important. Furthermore, the validated protocol workflow can be automated, thus providing consistent and rapid measurements of nanorod size and shape distributions for researchers, regulatory agencies, and industry.

  6. A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    PubMed

    Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao

    2017-08-28

    Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.

  7. Instrumental and statistical methods for the comparison of class evidence

    NASA Astrophysics Data System (ADS)

    Liszewski, Elisa Anne

    Trace evidence is a major field within forensic science. Association of trace evidence samples can be problematic due to sample heterogeneity and a lack of quantitative criteria for comparing spectra or chromatograms. The aim of this study is to evaluate different types of instrumentation for their ability to discriminate among samples of various types of trace evidence. Chemometric analysis, including techniques such as Agglomerative Hierarchical Clustering, Principal Components Analysis, and Discriminant Analysis, was employed to evaluate instrumental data. First, automotive clear coats were analyzed by using microspectrophotometry to collect UV absorption data. In total, 71 samples were analyzed with classification accuracy of 91.61%. An external validation was performed, resulting in a prediction accuracy of 81.11%. Next, fiber dyes were analyzed using UV-Visible microspectrophotometry. While several physical characteristics of cotton fiber can be identified and compared, fiber color is considered to be an excellent source of variation, and thus was examined in this study. Twelve dyes were employed, some being visually indistinguishable. Several different analyses and comparisons were done, including an inter-laboratory comparison and external validations. Lastly, common plastic samples and other polymers were analyzed using pyrolysis-gas chromatography/mass spectrometry, and their pyrolysis products were then analyzed using multivariate statistics. The classification accuracy varied dependent upon the number of classes chosen, but the plastics were grouped based on composition. The polymers were used as an external validation and misclassifications occurred with chlorinated samples all being placed into the category containing PVC.

  8. Evaluation of analytical performance based on partial order methodology.

    PubMed

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY

    EPA Science Inventory

    Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...

  10. Interlaboratory Variability of Slip Coefficient Testing for Bridge Coatings

    DOT National Transportation Integrated Search

    2014-12-01

    All steel bridge systems need some type of a corrosion protection scheme to ensure a serviceable life. The most common approach is to use a multilayered paint system with a zinc-rich primer. In addition to corrosion performance, other factors need to...

  11. Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

    NASA Technical Reports Server (NTRS)

    Obrien, T. Kevin; Martin, Roderick H.

    1992-01-01

    The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

  12. Web based tools for visualizing imaging data and development of XNATView, a zero footprint image viewer

    PubMed Central

    Gutman, David A.; Dunn, William D.; Cobb, Jake; Stoner, Richard M.; Kalpathy-Cramer, Jayashree; Erickson, Bradley

    2014-01-01

    Advances in web technologies now allow direct visualization of imaging data sets without necessitating the download of large file sets or the installation of software. This allows centralization of file storage and facilitates image review and analysis. XNATView is a light framework recently developed in our lab to visualize DICOM images stored in The Extensible Neuroimaging Archive Toolkit (XNAT). It consists of a PyXNAT-based framework to wrap around the REST application programming interface (API) and query the data in XNAT. XNATView was developed to simplify quality assurance, help organize imaging data, and facilitate data sharing for intra- and inter-laboratory collaborations. Its zero-footprint design allows the user to connect to XNAT from a web browser, navigate through projects, experiments, and subjects, and view DICOM images with accompanying metadata all within a single viewing instance. PMID:24904399

  13. An interlaboratory comparison of nanosilver characterisation and hazard identification: Harmonising techniques for high quality data.

    PubMed

    Jemec, Anita; Kahru, Anne; Potthoff, Annegret; Drobne, Damjana; Heinlaan, Margit; Böhme, Steffi; Geppert, Mark; Novak, Sara; Schirmer, Kristin; Rekulapally, Rohit; Singh, Shashi; Aruoja, Villem; Sihtmäe, Mariliis; Juganson, Katre; Käkinen, Aleksandr; Kühnel, Dana

    2016-02-01

    Within the FP7 EU project NanoValid a consortium of six partners jointly investigated the hazard of silver nanoparticles (AgNPs) paying special attention to methodical aspects that are important for providing high-quality ecotoxicity data. Laboratories were supplied with the same original stock dispersion of AgNPs. All partners applied a harmonised procedure for storage and preparation of toxicity test suspensions. Altogether ten different toxicity assays with a range of environmentally relevant test species from different trophic levels were conducted in parallel to AgNP characterisation in the respective test media. The paper presents a comprehensive dataset of toxicity values and AgNP characteristics like hydrodynamic sizes of AgNP agglomerates and the share (%) of Ag(+)-species (the concentration of Ag(+)-species in relation to the total measured concentration of Ag). The studied AgNP preparation (20.4±6.8 nm primary size, mean total Ag concentration 41.14 mg/L, 46-68% of soluble Ag(+)-species in stock, 123.8±12.2 nm mean z-average value in dH2O) showed extreme toxicity to crustaceans Daphnia magna, algae Pseudokirchneriella subcapitata and zebrafish Danio rerio embryos (EC50<0.01 mg total Ag/L), was very toxic in the in vitro assay with rainbow trout Oncorhynchus mykiss gut cells (EC50: 0.01-1 mg total Ag/L); toxic to bacteria Vibrio fischeri, protozoa Tetrahymena thermophila (EC50: 1-10 mg total Ag/L) and harmful to marine crustaceans Artemia franciscana (EC50: 10-100 mg total Ag/L). Along with AgNPs, also the toxicity of AgNO3 was analyzed. The toxicity data revealed the same hazard ranking for AgNPs and AgNO3 (i.e. the EC50 values were in the same order of magnitude) proving the importance of soluble Ag(+)-species analysis for predicting the hazard of AgNPs. The study clearly points to the need for harmonised procedures for the characterisation of NMs. Harmonised procedures should consider: (i) measuring the AgNP properties like hydrodynamic size and metal ions species in each toxicity test medium at a range of concentrations, and (ii) including soluble metal salt control both in toxicity testing as well as in Ag(+)-species measurements. The present study is among the first nanomaterial interlaboratory comparison studies with the aim to improve the hazard identification testing protocols. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. A conversion of CO2-ECBM related lab observations to reservoir requirements

    NASA Astrophysics Data System (ADS)

    Gensterblum, Yves; Merkel, Alexej; Busch, Andreas; Krooß, Bernhard

    2013-04-01

    To predict a CBM production profile either during primary or secondary production, aspects like coal permeability and porosity, density, ash and moisture content, initial gas-in-place (GIP) (from canister desorption tests), gas sorption capacity from laboratory isotherms (to obtain gas saturations and desorption pressure), gas diffusivities, coal volumetrics (thickness and areal extent) need to be understood as a minimum requirement. When dealing with CO2-ECBM selective adsorption, counter diffusion in the coal matrix, or coal shrinkage and swelling (from CH4 desorption and CO2 adsorption, respectively) and the influence of moisture need to be investigated in addition to the parameters above. During CO2-ECBM processes, the areal distribution of the CO2 injected is accomplished by flow through the cleat network. When CO2 is entering the coal matrix by a combined sorption/diffusion process it will adsorb to the coal inner surface and at the same time replace part of the CH4. This replacement occurs either by a reduction in the CH4 partial pressure or by a higher selective sorption of CO2 over CH4. Because of a concentration gradient between CH4 in the matrix compared to the cleat system, CH4 diffuses from the coal matrix into the cleat system where, by pressure drawdown towards a production well, it can be produced. In this context this presentation summarizes gas (CO2, CH4) and water sorption on coal and specifically addresses the following topics: • CH4 and CO2 sorption capacity as a function depth and rank • CO2 and CH4 sorption on natural coals and its dependence on coal specific parameters like coal rank, maceral composition or ash content (Busch and Gensterblum, 2011). • Water sorption on coal, its dependence on coal properties such as rank and coal chemistry and gas sorption in the presence of water (Busch and Gensterblum, 2011). • Uncertainties in reservoir characterisation (Gensterblum et al., 2010; Gensterblum et al., 2009) • Sorption uptake kinetic as a function of surface coverage and the influence of moisture on the kinetic Busch, A. and Gensterblum, Y., 2011. CBM and CO2-ECBM related sorption processes in coal: A review. International Journal of Coal Geology, 87: 49-71. Gensterblum, Y. et al., 2010. European inter-laboratory comparison of high pressure CO2 sorption isotherms II: Natural coals. International Journal of Coal Geology, 84(2): 115-124. Gensterblum, Y. et al., 2009. European inter-laboratory comparison of high pressure CO2 sorption isotherms. I: Activated carbon. Carbon, 47(13): 2958-2969.

  15. An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU 2-2001 procedure for assessment of image quality

    NASA Astrophysics Data System (ADS)

    Bergmann, Helmar; Dobrozemsky, Georg; Minear, Gregory; Nicoletti, Rudolf; Samal, Martin

    2005-05-01

    An inter-laboratory comparison study was conducted to assess the image quality of PET scanners in Austria. The survey included both dedicated PET scanners (D-PET, n = 8) and coincidence cameras (GC-PET, n = 7). Measurement of image quality was based on the NEMA (National Electrical Manufacturers Association) NU 2-2001 protocol and the IEC (International Electrotechnical Commission) body phantom. The latter contains six fillable spheres ranging in diameter from 37 mm down to 10 mm and a 'lung' insert. The two largest lesions L1-2 simulate cold lesions, the four smaller ones (L3-6) are filled with 18F and activity concentration ratios relative to background of 8:1 and 4:1, respectively. Acquisition and reconstruction in the study employed the participating institutes' standard oncological processing protocol. Calculation of contrast of the spheres was performed with a fully automated procedure. Contrast quality indices (CQIs) reflecting global performance were obtained by summing individual contrast values. Other image quality parameters calculated according to the NEMA protocol were background variability and relative error for correction of attenuation and scatter. Contrast values obtained were 61 ± 16 and 37 ± 14 for L1 (per cent contrast ± SD for D-PET and GC-PET, respectively), 57 ± 16 and 29 ± 16 for L2, 46 ± 10 and 26 ± 6.3 for L3, 37 ± 10 and 15 ± 4.3 for L4, 26 ± 11.5 and 6.1 ± 2.5 for L5, 14 ± 7.1 and 2.6 ± 2.6 for L6, with D-PET systems consistently being superior to GC-PET systems. CQIs permitted ranking of the scanners, also demonstrating a clear distinction between D-PET and GC-PET systems. Background variability was largest for GC-PET systems; the relative error of attenuation and scatter correction was significantly correlated with image quality for D-PET systems only. The study demonstrated considerable differences in image quality not only between GC-PET and D-PET systems but also between individual D-PET systems with possible consequences for clinical interpretation of images and measurement of quantitative indices such as the standardized uptake value. The study provided valuable feedback to the participants as well as baseline data for improving interchangeability of PET images and of quantitative indices between different laboratories.

  16. Interlaboratory variability in the quantification of new generation antiepileptic drugs based on external quality assessment data.

    PubMed

    Williams, John; Bialer, Meir; Johannessen, Svein I; Krämer, Günther; Levy, René; Mattson, Richard H; Perucca, Emilio; Patsalos, Philip N; Wilson, John F

    2003-01-01

    To assess interlaboratory variability in the determination of serum levels of new antiepileptic drugs (AEDs). Lyophilised serum samples containing clinically relevant concentrations of felbamate (FBM), gabapentin (GBP), lamotrigine (LTG), the monohydroxy derivative of oxcarbazepine (OCBZ; MHD), tiagabine (TGB), topiramate (TPM), and vigabatrin (VGB) were distributed monthly among 70 laboratories participating in the international Heathcontrol External Quality Assessment Scheme (EQAS). Assay results returned over a 15-month period were evaluated for precision and accuracy. The most frequently measured compound was LTG (65), followed by MHD (39), GBP (19), TPM (18), VGB (15), FBM (16), and TGB (8). High-performance liquid chromatography was the most commonly used assay technique for all drugs except for TPM, for which two thirds of laboratories used a commercial immunoassay. For all assay methods combined, precision was <11% for MHD, FBM, TPM, and LTG, close to 15% for GBP and VGB, and as high as 54% for TGB (p < 0.001). Mean accuracy values were <10% for all drugs other than TGB, for which measured values were on average 13.9% higher than spiked values, with a high variability around the mean (45%). No differences in precision and accuracy were found between methods, except for TPM, for which gas chromatography showed poorer accuracy compared with immunoassay and gas chromatography-mass spectrometry. With the notable exception of TGB, interlaboratory variability in the determination of new AEDs was comparable to that reported with older-generation agents. Poor assay performance is related more to individual operators than to the intrinsic characteristics of the method applied. Participation in an EQAS scheme is recommended to ensure adequate control of assay variability in therapeutic drug monitoring.

  17. Intact cell mass spectrometry (ICMS) used to type methicillin-resistant Staphylococcus aureus: media effects and inter-laboratory reproducibility.

    PubMed

    Walker, J; Fox, A J; Edwards-Jones, V; Gordon, D B

    2002-02-01

    Intact cell mass spectrometry (ICMS) rapidly analyses the surface composition of microorganisms providing rapid, discriminatory fingerprints for identification and subtyping of important nosocomial pathogens such as methicillin resistant Staphylocccus aureus (MRSA). In this study, ICMS using matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI TOF/MS) was assessed for the identification and subtyping of MRSA. An intra- and inter-laboratory reproducibility study was carried out and the effects of culture media (an important source of variation for ICMS) were also studied. Several media used for the cultural identification of MRSA were examined using a panel of well-characterised staphylococcal isolates (n=26). Six MRSA isolates were analysed over a 1-month period for intra-laboratory reproducibility on the same instrument and three different culture media. Spectra were consistent for each isolate between the four experiments on the same culture medium. Individual isolates produced different spectral profiles on different culture media. Spectra from organisms grown on Columbia blood agar contained more peaks (approximately 120) compared to Columbia agar (approximately 50) and methicillin mannitol salt agar (approximately 25). All 26 staphylococcal isolates were subjected to an inter-laboratory study on two MALDI instruments. For each isolate, the overall spectral profile was the same for each of the two instruments but the baseline threshold values was adjusted due to instrument differences in detector sensitivities. Differences between certain regions of the spectra reproducibly identified isolates belonging to the two major MRSA strains (EMRSA phage group 15 and 16). These results demonstrate ICMS with appropriate media selection is a rapid and reproducible technique for identification and discrimination of MRSA.

  18. Interlaboratory Evaluation of a Multiplexed High Information Content In Vitro Genotoxicity Assay

    PubMed Central

    Bryce, Steven M.; Bernacki, Derek T.; Bemis, Jeffrey C.; Spellman, Richard A.; Engel, Maria E.; Schuler, Maik; Lorge, Elisabeth; Heikkinen, Pekka T.; Hemmann, Ulrike; Thybaud, Véronique; Wilde, Sabrina; Queisser, Nina; Sutter, Andreas; Zeller, Andreas; Guérard, Melanie; Kirkland, David; Dertinger, Stephen D.

    2017-01-01

    We previously described a multiplexed in vitro genotoxicity assay based on flow cytometric analysis of detergent-liberated nuclei that are simultaneously stained with propidium iodide and labeled with fluorescent antibodies against p53, γH2AX, and phospho-histone H3. Inclusion of a known number of microspheres provides absolute nuclei counts. The work described herein was undertaken to evaluate the interlaboratory transferability of this assay, commercially known as MultiFlow™ DNA Damage Kit— p53, γH2AX, Phospho-histone H3. For these experiments seven laboratories studied reference chemicals from a group of 84 representing clastogens, aneugens, and non-genotoxicants. TK6 cells were exposed to chemicals in 96-well plates over a range of concentrations for 24 hrs. At 4 and 24 hrs cell aliquots were added to the MultiFlow reagent mix and following a brief incubation period flow cytometric analysis occurred, in most cases directly from a 96-well plate via a robotic walk-away data acquisition system. Multiplexed response data were evaluated using two analysis approaches, one based on global evaluation factors (i.e., cutoff values derived from all inter-laboratory data), and a second based on multinomial logistic regression that considers multiple biomarkers simultaneously. Both data analysis strategies were devised to categorize chemicals as predominately exhibiting a clastogenic, aneugenic, or non-genotoxic mode of action (MoA). Based on the aggregate 231 experiments that were performed, assay sensitivity, specificity, and concordance in relation to a priori MoA grouping were ≥ 92%. These results are encouraging as they suggest that two distinct data analysis strategies can rapidly and reliably predict new chemicals’ predominant genotoxic MoA based on data from an efficient and transferable multiplexed in vitro assay. PMID:28370322

  19. Quality of pathology reporting is crucial for cancer care and registration: a baseline assessment for breast cancers diagnosed in Belgium in 2008.

    PubMed

    De Schutter, H; Van Damme, N; Colpaert, C; Galant, C; Lambein, K; Cornelis, A; Neven, P; Van Eycken, E

    2015-04-01

    Given the crucial role of pathology reporting in the management of breast cancers, we aimed to investigate the quality and variability of breast cancer pathology reporting in Belgium. Detailed information on non-molecular and molecular parameters was retrieved from the pathology protocols available at the Belgian Cancer Registry for 10,007 breast cancers diagnosed in Belgium in 2008. Substantial underreporting was shown for several clinically relevant non-molecular parameters, such as lymphovascular invasion. High-volume laboratories performed only slightly better than others, and analyses at the individual laboratory level showed clear inter-laboratory variability in reporting for all volume categories. Information on ER/PR and HER2 IHC was mentioned in respectively 91.7% and 90.8% of evaluative cases. HER2 ISH data were available for 78.5% of the cases judged to be 2+ for HER2 IHC. For cases with different specimens analysed, discordance between these specimens was highest for HER2, followed by PR. For HER2, results obtained from different laboratories were even less concordant. In addition, inter-laboratory differences were noted in the used ER/PR scoring systems, the proportion of ER-/PR+ cases, and the relation between histological grade and ER/PR positivity. Data on Ki67 were only available for 43.8% of the investigated cases, and showed inconsistent use of cut-off values. Breast pathology reporting in Belgium in 2008 was suboptimal and showed considerable inter-laboratory variability. Synoptic reporting has been proposed as a facilitator towards increased reporting quality and harmonization, but the lack of aligned informatics remains a major hurdle in its concrete implementation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Interlaboratory evaluation of Hyalella azteca and Chironomus tentans short-term and long-term sediment toxicity tests

    USGS Publications Warehouse

    Norberg-King, T. J.; Sibley, P.K.; Burton, G.A.; Ingersoll, C.G.; Kemble, N.E.; Ireland, S.; Mount, D.R.; Rowland, C.D.

    2006-01-01

    Methods for assessing the long-term toxicity of sediments to Hyalella azteca and Chironomus tentans can significantly enhance the capacity to assess sublethal effects of contaminated sediments through multiple endpoints. Sublethal tests allow us to begin to understand the relationship between short-term and long-term effects for toxic sediments. We present an interlaboratory evaluation with long-term and 10-d tests using control and contaminated sediments in which we assess whether proposed and existing performance criteria (test acceptability criteria [TAC]) could be achieved. Laboratories became familiar with newly developed, long-term protocols by testing two control sediments in phase 1. In phase 2, the 10-d and long-term tests were examined with several sediments. Laboratories met the TACs, but results varied depending on the test organism, test duration, and endpoints. For the long-term tests in phase 1, 66 to 100% of the laboratories consistently met the TACs for survival, growth, or reproduction using H. azteca, and 70 to 100% of the laboratories met the TACs for survival and growth, emergence, reproduction, and hatchability using C. tentans. In phase 2, fewer laboratories participated in long-term tests: 71 to 88% of the laboratories met the TAC for H. azteca, whereas 50 to 67% met the TAC for C. tentans. In the 10-d tests with H. azteca, and C. tentans, 82 and 88% of the laboratories met the TAC for survival, respectively, and 80% met the TAC for C. tentans growth. For the 10-d and long-term tests, laboratories predicted similar toxicity. Overall, the interlaboratory evaluation showed good precision of the methods, appropriate endpoints were incorporated into the test protocols, and tests effectively predicted the toxicity of sediments.

  1. Proficiency testing program for the determination of total arsenic, cadmium, and lead in seawater shrimp.

    PubMed

    Kong, Mei-Fung; Chan, Serena; Wong, Yiu-Chung

    2008-01-01

    The proficiency testing (PT) program for 97 worldwide laboratories for determining total arsenic, cadmium, and lead in seawater shrimp under the auspices of the Asia-Pacific Laboratory Accreditation Cooperation (APLAC) is discussed. The program is one of the APLAC PT series whose primary purposes are to establish mutual agreement on the equivalence of the operation of APLAC member laboratories and to take corrective actions if testing deficiencies are identified. Pooled data for Cd and Pb were normally distributed with interlaboratory variations of 21.9 and 34.8%, respectively. The corresponding consensus mean values estimated by robust statistics were in good agreement with those obtained in the homogeneity tests. However, a bimodal distribution was observed from the determination of total As, in which 14 out of 74 participants reported much smaller values (0.482-6.4 mg/kg) as compared with the mean values of 60.9 mg/kg in the homogeneity test. The use of consensus mean is known to have significant deviation from the true value in bi- or multimodal distribution. Therefore, the mode value, a better estimate of central tendency, was chosen to assess participants' performance for total As. Estimates of the overall uncertainty from participants varied in this program, and some were recommended to acquire more comprehensive exposure toward important criteria as stipulated in ISO/IEC 17025.

  2. Development and initial evaluation of a reconstituted water formulation that better represents natural waters(poster)

    EPA Science Inventory

    The use of reconstituted waters is deeply entrenched in many standardized aquatic toxicity testing protocols The primary appeal of reconstituted waters is inter-laboratory comparability, such that experiments performed in different laboratories can be conducted in (nominally) id...

  3. Development and Initial Evaluation of a Reconstituted Water Formulation that Better Represents Natural Waters

    EPA Science Inventory

    The use of reconstituted waters is deeply entrenched in many standardized aquatic toxicity testing protocols. The primary appeal of reconstituted waters is inter-laboratory comparability, such that experiments performed in different laboratories can be conducted in (nominally) id...

  4. Collaborative analysis of wheat endosperm compressive material properties

    USDA-ARS?s Scientific Manuscript database

    The objective measurement of cereal endosperm texture, for wheat (Triticum L.) in particular, is relevant to the milling, processing and utilization of grain. The objective of this study was to evaluate the inter-laboratory results of compression failure testing of wheat endosperm specimens of defi...

  5. 9 CFR 439.51 - Probation of accreditation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ACCREDITATION OF NON-FEDERAL CHEMISTRY LABORATORIES § 439.51 Probation of accreditation. Upon a determination by the Administrator, a laboratory will be placed on probation for the following reasons: (a) If the laboratory fails to complete more than one interlaboratory accreditation maintenance check sample analysis as...

  6. An Experimental Introduction to Interlaboratory Exercises in Analytical Chemistry

    ERIC Educational Resources Information Center

    Puignou, L.; Llaurado, M.

    2005-01-01

    An experimental exercise on analytical proficiency studies in collaborative trials is proposed. This practical provides students in advanced undergraduate courses in chemistry, pharmacy, and biochemistry, with the opportunity to improve their quality assurance skills. It involves an environmental analysis, determining the concentration of a…

  7. Fish species identification using PCR-RFLP analysis and lab-on-a-chip capillary electrophoresis: application to detect white fish species in food products and an interlaboratory study.

    PubMed

    Dooley, John J; Sage, Helen D; Clarke, Marie-Anne L; Brown, Helen M; Garrett, Stephen D

    2005-05-04

    Identification of 10 white fish species associated with U.K. food products was achieved using PCR-RFLP of the mitochondrial cytochrome b gene. Use of lab-on-a-chip capillary electrophoresis for end-point analysis enabled accurate sizing of DNA fragments and identification of fish species at a level of 5% (w/w) in a fish admixture. One restriction enzyme, DdeI, allowed discrimination of eight species. When combined with NlaIII and HaeIII, specific profiles for all 10 species were generated. The method was applied to a range of products and subjected to an interlaboratory study carried out by five U.K. food control laboratories. One hundred percent correct identification of single species samples and six of nine admixture samples was achieved by all laboratories. The results indicated that fish species identification could be carried out using a database of PCR-RFLP profiles without the need for reference materials.

  8. Liquid chromatographic determination of histamine in fish, sauerkraut, and wine: interlaboratory study.

    PubMed

    Beljaars, P R; Van Dijk, R; Jonker, K M; Schout, L J

    1998-01-01

    An interlaboratory study of the liquid chromatographic (LC) determination of histamine in fish, sauerkraut, and wine was conducted. Diminuted and homogenized samples were suspended in water followed by clarification of extracts with perchloric acid, filtration, and dilution with water. After LC separation on a reversed-phase C18 column with phosphate buffer (pH 3.0)--acetonitrile (875 + 125, v/v) as mobile phase, histamine was measured fluorometrically (excitation, 340 nm; emission, 455 nm) in samples and standards after postcolumn derivatization with o-phthaldialdehyde (OPA). Fourteen samples (including 6 blind duplicates and 1 split level) containing histamine at about 10-400 mg/kg or mg/L were analyzed singly according to the proposed procedure by 11 laboratories. Results from one participant were excluded from statistical analysis. For all samples analyzed, repeatability relative standard deviations varied from 2.1 to 5.6%, and reproducibility relative standard deviations ranged from 2.2 to 7.1%. Averaged recoveries of histamine for this concentration range varied from 94 to 100%.

  9. Determination of Minor and Trace Metals in Aluminum and Aluminum Alloys by ICP-AES; Evaluation of the Uncertainty and Limit of Quantitation from Interlaboratory Testing.

    PubMed

    Uemoto, Michihisa; Makino, Masanori; Ota, Yuji; Sakaguchi, Hiromi; Shimizu, Yukari; Sato, Kazuhiro

    2018-01-01

    Minor and trace metals in aluminum and aluminum alloys have been determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) as an interlaboratory testing toward standardization. The trueness of the measured data was successfully investigated to improve the analytical protocols, using certified reference materials of aluminum. Their precision could also be evaluated, feasible to estimate the uncertainties separately. The accuracy (trueness and precision) of the data were finally in good agreement with the certified values and assigned uncertainties. Repeated measurements of aluminum solutions with different concentrations of the analytes revealed the relative standard deviations of the measurements with concentrations, thus enabling their limits of quantitation. They differed separately and also showed slightly higher values with an aluminum matrix than those without one. In addition, the upper limit of the detectable concentration of silicon with simple acid digestion was estimated to be 0.03 % in the mass fraction.

  10. Increased frequencies of aberrant sperm as indicators of mutagenic damage in mice.

    PubMed

    Soares, E R; Sheridan, W; Haseman, J K; Segall, M

    1979-02-01

    We have tested the effects of TEM in 3 strains of mice using the sperm morphology assay. In addition, we have made an attempt to evaluate this test system with respect to experimental design, statistical problems and possible interlaboratory differences. Treatment with TEM results in significant increases in the percent of abnormally shaped sperm. These increases are readily detectable in sperm treated as spermatocytes and spermatogonial stages. Our data indicate possible problems associated with inter-laboratory variation in slide analysis. We have found that despite the introduction of such sources of variation, our data were consistent with respect to the effects of TEM. Another area of concern in the sperm morphology test is the presence of "outlier" animals. In our study, such animals comprised 4% of the total number of animals considered. Statistical analysis of the slides from these animals have shown that this problem can be dealt with and that when recognized as such, "outliers" do not effect the outcome of the sperm morphology assay.

  11. Forensic interlaboratory evaluation of the ForFLUID kit for vaginal fluids identification.

    PubMed

    Giampaoli, Saverio; Alessandrini, Federica; Berti, Andrea; Ripani, Luigi; Choi, Ajin; Crab, Roselien; De Vittori, Elisabetta; Egyed, Balazs; Haas, Cordula; Lee, Hwan Young; Korabecná, Marie; Noel, Fabrice; Podini, Daniele; Tagliabracci, Adriano; Valentini, Alessio; Romano Spica, Vincenzo

    2014-01-01

    Identification of vaginal fluids is an important step in the process of sexual assaults confirmation. Advances in both microbiology and molecular biology defined technical approaches allowing the discrimination of body fluids. These protocols are based on the identification of specific bacterial communities by microfloraDNA (mfDNA) amplification. A multiplex real time-PCR assay (ForFLUID kit) has been developed for identifying biological fluids and for discrimination among vaginal, oral and fecal samples. In order to test its efficacy and reliability of the assay in the identification of vaginal fluids, an interlaboratory evaluation has been performed on homogeneous vaginal swabs. All the involved laboratories were able to correctly recognize all the vaginal swabs, and no false positives were identified when the assay was applied on non-vaginal samples. The assay represents an useful molecular tool that can be easily adopted by forensic geneticists involved in vaginal fluid identification. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  12. Transferability and inter-laboratory variability assessment of the in vitro bovine oocyte fertilization test.

    PubMed

    Tessaro, Irene; Modina, Silvia C; Crotti, Gabriella; Franciosi, Federica; Colleoni, Silvia; Lodde, Valentina; Galli, Cesare; Lazzari, Giovanna; Luciano, Alberto M

    2015-01-01

    The dramatic increase in the number of animals required for reproductive toxicity testing imposes the validation of alternative methods to reduce the use of laboratory animals. As we previously demonstrated for in vitro maturation test of bovine oocytes, the present study describes the transferability assessment and the inter-laboratory variability of an in vitro test able to identify chemical effects during the process of bovine oocyte fertilization. Eight chemicals with well-known toxic properties (benzo[a]pyrene, busulfan, cadmium chloride, cycloheximide, diethylstilbestrol, ketoconazole, methylacetoacetate, mifepristone/RU-486) were tested in two well-trained laboratories. The statistical analysis demonstrated no differences in the EC50 values for each chemical in within (inter-runs) and in between-laboratory variability of the proposed test. We therefore conclude that the bovine in vitro fertilization test could advance toward the validation process as alternative in vitro method and become part of an integrated testing strategy in order to predict chemical hazards on mammalian fertility. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates, Phase II Results

    NASA Technical Reports Server (NTRS)

    Allen, P. A.; Wells, D. N.

    2017-01-01

    The second phase of an analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted under the auspices of ASTM Interlaboratory Study 732. The interlaboratory study (ILS) had 10 participants with a broad range of expertise and experience, and experimental results from a surface crack tension test in 4142 steel plate loaded well into the elastic-plastic regime provided the basis for the study. The participants were asked to evaluate a surface crack tension test according to the version of the surface crack initiation toughness testing standard published at the time of the ILS, E2899-13. Data were provided to each participant that represent the fundamental information that would be provided by a mechanical test laboratory prior to evaluating the test result. Overall, the participant’s test analysis results were in good agreement and constructive feedback was received that has resulted in an improved published version of the standard E2899-15.

  14. Measurement of IgE antibodies using liquid allergens--an inter-method and inter-laboratory quality assessment.

    PubMed

    Aberer, Werner; Kränke, Birger

    2002-11-30

    The determination of IgE antibodies is important for the in vitro diagnosis of allergic diseases. However, not all systems currently available in the market fulfill essential quality criteria, e.g. regarding characteristics such as sensitivity and specificity, and the data do not always reflect true clinical relevance in the required fashion. Recent innovations may reduce the workload for the technician, and thus help save time and money. More importantly, they might reduce potential sources of error. Two allergy systems, the well established Pharmacia CAP system that uses the allergens conventionally in a solid phase and the ALLERgen system that employs liquid allergens, were compared with regard to quality criteria and practicability. Defined serum pools were checked for within-run and between-days imprecision of IgE antibody detection in two independent laboratories. Serum specimens from allergic patients and controls were tested in parallel using both methods for total and antigen-specific IgE antibody detection under standardized conditions. In addition, one laboratory working exclusively with the ALLERgen system participated in the Austrian inter-laboratory quality assessment program. The two systems were comparable in terms of sensitivity and specificity, and also showed good correlation. Within-run evaluations were excellent for total IgE and antigen-specific IgE, and the between-days imprecision was satisfactory. Coefficients of variation were within an acceptable range for the different groups of allergens. In the external quality control program the data obtained with the ALLERgen system showed good concordance with other systems in use; up to 94% of the results were identical when considering clinically relevant sensitizations. Regarding practicability, both systems were most satisfactory for the operator. The ALLERgen system offered a certain advantage in terms of automated operation, which resulted in shorter fixed and variable phases of personnel time. Both the Pharmacia CAP system and the ALLERgen system belong to an advanced generation of allergy test systems and are easy to handle. The reproducibility of results is good with both methods, and the imprecision data fall within an acceptable range. Thus, the ALLERgen system is a reliable in vitro system for evaluating specific and total IgE in serum, providing data equivalent to those obtained with the CAP system.

  15. Determination of total cadmium, lead, arsenic, mercury and inorganic arsenic in mushrooms: outcome of IMEP-116 and IMEP-39

    PubMed Central

    Cordeiro, F.; Llorente-Mirandes, T.; López-Sánchez, J.F.; Rubio, R.; Sánchez Agullo, A.; Raber, G.; Scharf, H.; Vélez, D.; Devesa, V.; Fiamegos, Y.; Emteborg, H.; Seghers, J.; Robouch, P.; de la Calle, M.B.

    2015-01-01

    The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (X ref). The standard uncertainties associated to the assigned values (u ref) were calculated by combining the uncertainty of the characterisation (u char) with a contribution for homogeneity (u bb) and for stability (u st), whilst u char was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σ p, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39. PMID:25365736

  16. Implementation of the Bethesda System for Reporting Thyroid Cytopathology: observations from the 2011 thyroid supplemental questionnaire of the College of American Pathologists.

    PubMed

    Auger, Manon; Nayar, Ritu; Khalbuss, Walid E; Barkan, Güliz A; Benedict, Cynthia C; Tambouret, Rosemary; Schwartz, Mary R; Howell, Lydia P; Souers, Rhona J; Hartley, David A; Thomas, Nicole; Moriarty, Ann T

    2013-11-01

    Although information about the Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) has been widely disseminated since its inception in 2007, the extent of its implementation and impact on daily practice has not been formally evaluated. To assess the extent of uptake of TBSRTC across pathology laboratories and to evaluate its impact on daily practice by collating participant responses to the 2011 supplemental thyroid questionnaire of the College of American Pathologists. A questionnaire was designed to gather information about various aspects of TBSRTC and mailed in June 2011 to 2063 laboratories participating in the College of American Pathologists cytopathology interlaboratory comparison program. The participating laboratories' answers were collated and summarized. Seven hundred and seventy-seven laboratories (37.6%) returned the survey. Although 60.9% (n = 451) and 17.1% (n = 127) of laboratories reported using TBSRTC or planning to use it in the near future, respectively, 22% (n = 163) had no plans to implement TBSRTC. Of the latter, 32% (n = 70) stated that they were unaware of this classification system. The majority (78.3%, n = 343) of the laboratories used TBSRTC as published in the Thyroid Bethesda System atlas, whereas 21.7% (n = 95) used it with minor modifications. Most reported that the use of TBSRTC had caused either no change (n = 67, 15.2%) or only minor changes (n = 353, 80.2%) in the terminology and diagnostic criteria previously used in their laboratories. According to the collected data, TBSRTC is generally well implemented in pathology laboratories. However, because approximately a third of those not using this terminology are not aware of it, additional educational efforts regarding TBSRTC are warranted.

  17. Determination of total cadmium, lead, arsenic, mercury and inorganic arsenic in mushrooms: outcome of IMEP-116 and IMEP-39.

    PubMed

    Cordeiro, F; Llorente-Mirandes, T; López-Sánchez, J F; Rubio, R; Sánchez Agullo, A; Raber, G; Scharf, H; Vélez, D; Devesa, V; Fiamegos, Y; Emteborg, H; Seghers, J; Robouch, P; de la Calle, M B

    2015-01-01

    The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39.

  18. Results of an inter-laboratory study of glass formulation for the immobilization of excess plutonium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peeler, D.K.

    1999-12-08

    The primary focus of the current study is to determine allowable loadings of feed streams containing different ratios of plutonium, uranium, and minor components into the LaBS glass and to evaluate thermal stability with respect to the DWPF pour.

  19. Development of micro-electrode array based tests for neurotoxicity: assessment of interlaboratory reproducibility with neuroactive chemicals

    EPA Science Inventory

    Neuronal assemblies within the Central Nervous System (CNS) produce spontaneous or stimulus-evoked electrophysiological activity that can be monitored and quantified in terms of action potential patterns. Such patterns provide a sensitive endpoint to detect effects of chemicals, ...

  20. CAPILLARY GAS CHROMATOGRAPHY-ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF PENTYLATED ORGANOTIN COMPOUNDS: INTERLABORATORY STUDY

    EPA Science Inventory

    A capillary gas chromatography-atomic emission detection (GC-AED) method was developed for the U. S. Environmental Protection Agency's Environmental Monitoring Systems Laboratory in Las Vegas, NV, for determination of selected organotin compounds. Here we report on an interlabora...

  1. Intra- and inter-laboratory reliability of a cryopreserved trout hepatocyte assay for the prediction of chemical bioaccumulation potential

    EPA Science Inventory

    Cryopreserved trout hepatocytes provide a convenient in vitro system for measuring the intrinsic clearance of xenobiotics. Measured clearance rates can then be extrapolated to the whole animal as a means of improving modeled bioaccumulation predictions. To date, however, the in...

  2. Evaluation of the repeatability and reproducibility of a suite of qPCR based microbial source tracking methods

    EPA Science Inventory

    Many PCR-based methods for microbial source tracking (MST) have been developed and validated within individual research laboratories. Inter-laboratory validation of these methods, however, has been minimal, and the effects of protocol standardization regimes have not been thor...

  3. THE DETERMINATION OF TOTAL ORGANIC HALIDE IN WATER: AN INTERLABORATORY COMPARATIVE STUDY OF TWO METHODS

    EPA Science Inventory

    Total organic halide (TOX) analyzers are commonly used to measure the amount of dissolved halogenated organic byproducts in disinfected waters. Because of the lack of information on the identity of disinfection byproducts, rigorous testing of the dissolved organic halide (DOX) pr...

  4. An interlaboratory study measuring sex steroids with RIAs and/or ELISAs: Are we comparing apples to oranges?

    EPA Science Inventory

    Endocrine-disrupting chemicals (EDCs) are exogenous substances released into the environment that can lead to adverse reproductive effects in fish by a number of mechanisms including altering circulating levels of estradiol (E2), testosterone (T) and 11-ketotestosterone (11KT). ...

  5. INTERLABORATORY STUDY OF THE COLD VAPOR TECHNIQUE FOR TOTAL MERCURY IN WATER

    EPA Science Inventory

    The American Society for Testing and Materials (ASTM) and the U.S. Environmental Protection Agency (EPA) conducted a joint study of the cold vapor technique for total mercury in water, before formal acceptance of the method by each organization. The method employs an acid-permang...

  6. AN INTERLABORATORY STUDY ON THE USE OF STEROID HORMONES IN EVALUATING ENDOCRINE DISRUPTION

    EPA Science Inventory

    In recent years, there has been an increased use of the measurement of sex steroid hormone levels in the blood of animals exposed to chemicals as an indicator of reproductive impairment or an alteration in endocrine function. Although levels of hormones are often compared among a...

  7. INTERLABORATORY STUDY ON THE USE OF STEROID HORMONES IN EXAMINING ENDOCRINE DISRUPTION.

    EPA Science Inventory

    In recent years, there has been an increased use of the measurement of sex steroid hormone levels in the blood of animals exposed to chemicals as an indicator of reproductive impairment or an alteration in endocrine function. Although levels of hormones are often compared among ...

  8. AN INTERLABORATORY STUDY ON THE USE OF STERIOD HORMONES IN EXAMINING ENDOCRINE DISRUPTION.

    EPA Science Inventory

    In recent years, there has been an increased use of the measurement of sex steroid hormone levels in the blood of animals exposed to chemicals as an indicator of reproductive impairment or an alteration in endocrine function. Although levels of hormones are often compared among a...

  9. Touryan Elected Chairman

    Science.gov Websites

    Touryan Elected Chairman of Proliferation Prevention Advisory Board For information contact: e:mail ) National Renewable Energy Laboratory (NREL) was elected chairman of the Inter-Laboratory Advisory Board for opportunities and a means of rapid commercialization of defense technologies. It creates a win-win situation for

  10. INTERLABORATORY VALIDATION OF USEPA METHOD 1680: FECAL COLIFORMS IN BIOSOLIDS BY MULTIPLE-TUBE FERMENTATION PROCEDURES

    EPA Science Inventory

    In the US, the use and disposal of biosolids (including domestic septage) are regulated under 40 CFR Part 503. Subpart D of this regulation protects public health and the environment through requirements designed to reduce the potential for contact with pathogens in biosolids app...

  11. INTERLABORATORY VALIDATION OF USEPA METHOD 1680: FECAL COLIFORMS IN BIOSOLIDS BY MULTIPLE-TUBE FERMENTATION PROCEDURES

    EPA Science Inventory

    In the United States, the use and disposal of biosolids (including domestic septage) are regulated under 40 CFR Part 503. Subpart D of this regulation protects public health and the environment through requirements designed to reduce the potential for contact with pathogens in bi...

  12. Producing standard damaged DNA samples by heating: pitfalls and suggestions.

    PubMed

    Fattorini, Paolo; Marrubini, Giorgio; Bonin, Serena; Bertoglio, Barbara; Grignani, Pierangela; Recchia, Elisa; Pitacco, Paola; Procopio, Francesca; Cantoni, Carolina; Pajnič, Irena Zupanič; Sorçaburu-Cigliero, Solange; Previderè, Carlo

    2018-05-15

    Heat-mediated hydrolysis of DNA is a simple and inexpensive method for producing damaged samples in vitro. Despite heat-mediated DNA hydrolysis is being widely used in forensic and clinical validation procedures, the lack of standardized procedures makes it impossible to compare the intra and inter-laboratory outcomes of the damaging treatments. In this work, a systematic approach to heat induced DNA hydrolysis was performed at 70 °C for 0-18 h to test the role both of the hydrolysis buffer and of the experimental conditions. Specifically, a trial DNA sample, resuspended in three different media (ultrapure water, 0.1% DEPC-water and, respectively, TE) was treated both in Eppendorf tubes ("Protocol P") and in Eppendorf tubes provided with screwcaps ("Protocol S"). The results of these comparative tests were assessed by normalization of the qPCR results. DEPC-water increased the degradation of the samples up to about 100 times when compared to the ultrapure water. Conversely, the TE protected the DNA from degradation whose level was about 1700 times lower than in samples treated in ultrapure water. Even the employment of the "Protocol S" affected the level of degradation, by consistently increasing it (up to about 180 times in DEPC-water). Thus, this comparative approach showed that even seemingly apparently trivial and often underestimated parameters modify the degradation level up to 2-3 orders of magnitude. The chemical-physical reasons of these findings are discussed together with the role of potential factors such as enhanced reactivity of CO 2 , ROS, NO x and pressure, which are likely to be involved. Since the intra and inter-laboratory comparison of the outcomes of the hydrolytic procedure is the first step toward its standardization, the normalization of the qPCR data by the UV/qPCR ratio seems to be the simplest and most reliable way to allow this. Finally, the supplying (provided with the commercial qPCR kits) of a DNA sample whose degree of degradation is well documented could be helpful in ISO/IEC 17025 validation procedures and in proficiency testing. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Data processing of qualitative results from an interlaboratory comparison for the detection of “Flavescence dorée” phytoplasma: How the use of statistics can improve the reliability of the method validation process in plant pathology

    PubMed Central

    Renaudin, Isabelle; Poliakoff, Françoise

    2017-01-01

    A working group established in the framework of the EUPHRESCO European collaborative project aimed to compare and validate diagnostic protocols for the detection of “Flavescence dorée” (FD) phytoplasma in grapevines. Seven molecular protocols were compared in an interlaboratory test performance study where each laboratory had to analyze the same panel of samples consisting of DNA extracts prepared by the organizing laboratory. The tested molecular methods consisted of universal and group-specific real-time and end-point nested PCR tests. Different statistical approaches were applied to this collaborative study. Firstly, there was the standard statistical approach consisting in analyzing samples which are known to be positive and samples which are known to be negative and reporting the proportion of false-positive and false-negative results to respectively calculate diagnostic specificity and sensitivity. This approach was supplemented by the calculation of repeatability and reproducibility for qualitative methods based on the notions of accordance and concordance. Other new approaches were also implemented, based, on the one hand, on the probability of detection model, and, on the other hand, on Bayes’ theorem. These various statistical approaches are complementary and give consistent results. Their combination, and in particular, the introduction of new statistical approaches give overall information on the performance and limitations of the different methods, and are particularly useful for selecting the most appropriate detection scheme with regards to the prevalence of the pathogen. Three real-time PCR protocols (methods M4, M5 and M6 respectively developed by Hren (2007), Pelletier (2009) and under patent oligonucleotides) achieved the highest levels of performance for FD phytoplasma detection. This paper also addresses the issue of indeterminate results and the identification of outlier results. The statistical tools presented in this paper and their combination can be applied to many other studies concerning plant pathogens and other disciplines that use qualitative detection methods. PMID:28384335

  14. Data processing of qualitative results from an interlaboratory comparison for the detection of "Flavescence dorée" phytoplasma: How the use of statistics can improve the reliability of the method validation process in plant pathology.

    PubMed

    Chabirand, Aude; Loiseau, Marianne; Renaudin, Isabelle; Poliakoff, Françoise

    2017-01-01

    A working group established in the framework of the EUPHRESCO European collaborative project aimed to compare and validate diagnostic protocols for the detection of "Flavescence dorée" (FD) phytoplasma in grapevines. Seven molecular protocols were compared in an interlaboratory test performance study where each laboratory had to analyze the same panel of samples consisting of DNA extracts prepared by the organizing laboratory. The tested molecular methods consisted of universal and group-specific real-time and end-point nested PCR tests. Different statistical approaches were applied to this collaborative study. Firstly, there was the standard statistical approach consisting in analyzing samples which are known to be positive and samples which are known to be negative and reporting the proportion of false-positive and false-negative results to respectively calculate diagnostic specificity and sensitivity. This approach was supplemented by the calculation of repeatability and reproducibility for qualitative methods based on the notions of accordance and concordance. Other new approaches were also implemented, based, on the one hand, on the probability of detection model, and, on the other hand, on Bayes' theorem. These various statistical approaches are complementary and give consistent results. Their combination, and in particular, the introduction of new statistical approaches give overall information on the performance and limitations of the different methods, and are particularly useful for selecting the most appropriate detection scheme with regards to the prevalence of the pathogen. Three real-time PCR protocols (methods M4, M5 and M6 respectively developed by Hren (2007), Pelletier (2009) and under patent oligonucleotides) achieved the highest levels of performance for FD phytoplasma detection. This paper also addresses the issue of indeterminate results and the identification of outlier results. The statistical tools presented in this paper and their combination can be applied to many other studies concerning plant pathogens and other disciplines that use qualitative detection methods.

  15. Interlaboratory Comparison of Sample Preparation Methods, Database Expansions, and Cutoff Values for Identification of Yeasts by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using a Yeast Test Panel

    PubMed Central

    Vlek, Anneloes; Kolecka, Anna; Khayhan, Kantarawee; Theelen, Bart; Groenewald, Marizeth; Boel, Edwin

    2014-01-01

    An interlaboratory study using matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) to determine the identification of clinically important yeasts (n = 35) was performed at 11 clinical centers, one company, and one reference center using the Bruker Daltonics MALDI Biotyper system. The optimal cutoff for the MALDI-TOF MS score was investigated using receiver operating characteristic (ROC) curve analyses. The percentages of correct identifications were compared for different sample preparation methods and different databases. Logistic regression analysis was performed to analyze the association between the number of spectra in the database and the percentage of strains that were correctly identified. A total of 5,460 MALDI-TOF MS results were obtained. Using all results, the area under the ROC curve was 0.95 (95% confidence interval [CI], 0.94 to 0.96). With a sensitivity of 0.84 and a specificity of 0.97, a cutoff value of 1.7 was considered optimal. The overall percentage of correct identifications (formic acid-ethanol extraction method, score ≥ 1.7) was 61.5% when the commercial Bruker Daltonics database (BDAL) was used, and it increased to 86.8% by using an extended BDAL supplemented with a Centraalbureau voor Schimmelcultures (CBS)-KNAW Fungal Biodiversity Centre in-house database (BDAL+CBS in-house). A greater number of main spectra (MSP) in the database was associated with a higher percentage of correct identifications (odds ratio [OR], 1.10; 95% CI, 1.05 to 1.15; P < 0.01). The results from the direct transfer method ranged from 0% to 82.9% correct identifications, with the results of the top four centers ranging from 71.4% to 82.9% correct identifications. This study supports the use of a cutoff value of 1.7 for the identification of yeasts using MALDI-TOF MS. The inclusion of enough isolates of the same species in the database can enhance the proportion of correctly identified strains. Further optimization of the preparation methods, especially of the direct transfer method, may contribute to improved diagnosis of yeast-related infections. PMID:24920782

  16. Community-based Approaches to Improving Accuracy, Precision, and Reproducibility in U-Pb and U-Th Geochronology

    NASA Astrophysics Data System (ADS)

    McLean, N. M.; Condon, D. J.; Bowring, S. A.; Schoene, B.; Dutton, A.; Rubin, K. H.

    2015-12-01

    The last two decades have seen a grassroots effort by the international geochronology community to "calibrate Earth history through teamwork and cooperation," both as part of the EARTHTIME initiative and though several daughter projects with similar goals. Its mission originally challenged laboratories "to produce temporal constraints with uncertainties approaching 0.1% of the radioisotopic ages," but EARTHTIME has since exceeded its charge in many ways. Both the U-Pb and Ar-Ar chronometers first considered for high-precision timescale calibration now regularly produce dates at the sub-per mil level thanks to instrumentation, laboratory, and software advances. At the same time new isotope systems, including U-Th dating of carbonates, have developed comparable precision. But the larger, inter-related scientific challenges envisioned at EARTHTIME's inception remain - for instance, precisely calibrating the global geologic timescale, estimating rates of change around major climatic perturbations, and understanding evolutionary rates through time - and increasingly require that data from multiple geochronometers be combined. To solve these problems, the next two decades of uranium-daughter geochronology will require further advances in accuracy, precision, and reproducibility. The U-Th system has much in common with U-Pb, in that both parent and daughter isotopes are solids that can easily be weighed and dissolved in acid, and have well-characterized reference materials certified for isotopic composition and/or purity. For U-Pb, improving lab-to-lab reproducibility has entailed dissolving precisely weighed U and Pb metals of known purity and isotopic composition together to make gravimetric solutions, then using these to calibrate widely distributed tracers composed of artificial U and Pb isotopes. To mimic laboratory measurements, naturally occurring U and Pb isotopes were also mixed in proportions to mimic samples of three different ages, to be run as internal standards and as measures of inter-laboratory reproducibility. The U-Th community is undertaking many of the same protocols, and has recently created publicly available gravimetric solutions, and large volumes of three age solutions for widespread distribution and inter-laboratory comparison.

  17. A Recombinant Positive Control for Serology Diagnostic Tests Supporting Elimination of Onchocerca volvulus.

    PubMed

    Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J

    2016-01-01

    Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive control will benefit inter-laboratory validation of ELISA assays and serve as quality control (QC) reagents for Ov16 RDTs at different points of the supply chain from manufacturer to field use.

  18. Challenges in the size analysis of a silica nanoparticle mixture as candidate certified reference material

    NASA Astrophysics Data System (ADS)

    Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; De Temmerman, Pieter-Jan; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik

    2016-06-01

    A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.

  19. A Method for Identification and Analysis of Non-Overlapping Myeloid Immunophenotypes in Humans

    PubMed Central

    Gustafson, Michael P.; Lin, Yi; Maas, Mary L.; Van Keulen, Virginia P.; Johnston, Patrick B.; Peikert, Tobias; Gastineau, Dennis A.; Dietz, Allan B.

    2015-01-01

    The development of flow cytometric biomarkers in human studies and clinical trials has been slowed by inconsistent sample processing, use of cell surface markers, and reporting of immunophenotypes. Additionally, the function(s) of distinct cell types as biomarkers cannot be accurately defined without the proper identification of homogeneous populations. As such, we developed a method for the identification and analysis of human leukocyte populations by the use of eight 10-color flow cytometric protocols in combination with novel software analyses. This method utilizes un-manipulated biological sample preparation that allows for the direct quantitation of leukocytes and non-overlapping immunophenotypes. We specifically designed myeloid protocols that enable us to define distinct phenotypes that include mature monocytes, granulocytes, circulating dendritic cells, immature myeloid cells, and myeloid derived suppressor cells (MDSCs). We also identified CD123 as an additional distinguishing marker for the phenotypic characterization of immature LIN-CD33+HLA-DR- MDSCs. Our approach permits the comprehensive analysis of all peripheral blood leukocytes and yields data that is highly amenable for standardization across inter-laboratory comparisons for human studies. PMID:25799053

  20. QCloud: A cloud-based quality control system for mass spectrometry-based proteomics laboratories

    PubMed Central

    Chiva, Cristina; Olivella, Roger; Borràs, Eva; Espadas, Guadalupe; Pastor, Olga; Solé, Amanda

    2018-01-01

    The increasing number of biomedical and translational applications in mass spectrometry-based proteomics poses new analytical challenges and raises the need for automated quality control systems. Despite previous efforts to set standard file formats, data processing workflows and key evaluation parameters for quality control, automated quality control systems are not yet widespread among proteomics laboratories, which limits the acquisition of high-quality results, inter-laboratory comparisons and the assessment of variability of instrumental platforms. Here we present QCloud, a cloud-based system to support proteomics laboratories in daily quality assessment using a user-friendly interface, easy setup, automated data processing and archiving, and unbiased instrument evaluation. QCloud supports the most common targeted and untargeted proteomics workflows, it accepts data formats from different vendors and it enables the annotation of acquired data and reporting incidences. A complete version of the QCloud system has successfully been developed and it is now open to the proteomics community (http://qcloud.crg.eu). QCloud system is an open source project, publicly available under a Creative Commons License Attribution-ShareAlike 4.0. PMID:29324744

  1. Development, Validation, and Interlaboratory Evaluation of a Quantitative Multiplexing Method To Assess Levels of Ten Endogenous Allergens in Soybean Seed and Its Application to Field Trials Spanning Three Growing Seasons.

    PubMed

    Hill, Ryan C; Oman, Trent J; Wang, Xiujuan; Shan, Guomin; Schafer, Barry; Herman, Rod A; Tobias, Rowel; Shippar, Jeff; Malayappan, Bhaskar; Sheng, Li; Xu, Austin; Bradshaw, Jason

    2017-07-12

    As part of the regulatory approval process in Europe, comparison of endogenous soybean allergen levels between genetically engineered (GE) and non-GE plants has been requested. A quantitative multiplex analytical method using tandem mass spectrometry was developed and validated to measure 10 potential soybean allergens from soybean seed. The analytical method was implemented at six laboratories to demonstrate the robustness of the method and further applied to three soybean field studies across multiple growing seasons (including 21 non-GE soybean varieties) to assess the natural variation of allergen levels. The results show environmental factors contribute more than genetic factors to the large variation in allergen abundance (2- to 50-fold between environmental replicates) as well as a large contribution of Gly m 5 and Gly m 6 to the total allergen profile, calling into question the scientific rational for measurement of endogenous allergen levels between GE and non-GE varieties in the safety assessment.

  2. Screening protocol for Torulopsis (Candida) glabrata.

    PubMed Central

    Land, G; Burke, J; Shelby, C; Rhodes, J; Collett, J; Bennett, I; Johnson, J

    1996-01-01

    A screening test has been developed for the presumptive identification of Torulopsis (Candida) glabrata from other common clinical isolates of yeast-like fungi. An interlaboratory comparison of a protocol consisting of morphology on cornmeal Tween 80 agar and trehalose fermentation at 42 degrees C was successful in differentiating T. glabrata from other taxa that are frequent or possible clinical isolates. The screening results for 517 clinical yeast isolates, 241 of which were T. glabrata, were compared with their final identification via commercial systems (API20C Yeast Identification System [bioMERIEUX, Hazelwood, Mo.] and Rapid Yeast Identification Panel [Dade Microscan, Sacramento, Calif.]). The trehalose screening test has a sensitivity and a specificity of 97.8 and 95.8%, respectively, and a positive predictive value of 97.4% and a negative predictive value of 96.5%. Overall, the trehalose screen had an efficiency rating of 93.9% for ruling in or out T. glabrata. Since T. glabrata represents a substantial part of the workload in a clinical laboratory, a significant reduction in direct and indirect costs should be realized. PMID:8862605

  3. Polyfluorinated substances in abiotic standard reference ...

    EPA Pesticide Factsheets

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781. Journal article published in Analytical and Bioanalytical Chemistry

  4. Polyfluorinated substances in abiotic standard reference materials.

    PubMed

    Reiner, Jessica L; Blaine, Andrea C; Higgins, Christopher P; Huset, Carin; Jenkins, Thomas M; Kwadijk, Christiaan J A F; Lange, Cleston C; Muir, Derek C G; Reagen, William K; Rich, Courtney; Small, Jeff M; Strynar, Mark J; Washington, John W; Yoo, Hoon; Keller, Jennifer M

    2015-04-01

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781.

  5. Comparison of serum copper determination by colorimetric and atomic absorption spectrometric methods in seven different laboratories. The S.F.B.C. (Société Française de Biologie Clinique) Trace Element Group.

    PubMed

    Arnaud, J; Chappuis, P; Zawislak, R; Houot, O; Jaudon, M C; Bienvenu, F; Bureau, F

    1993-02-01

    An interlaboratory collaborative trial was conducted on the determination of serum copper using two different methods, based on colorimetry (test combination Copper, Boehringer Mannheim, Mannheim, Germany) and flame atomic absorption spectrometry (FAAS). The general performance of the colorimetric method was below that of FAAS, except for sensitivity and linear range, as assessed by detection limit (0.44 versus 1.32 mumol/L) and upper limit of linearity (150 versus 50 mumol/L). The range of the between-run CVs and the recovery of standard additions were, respectively, 2.3-11.9% and 92-127% for the colorimetric method and 1.1-6.0% and 93-101% for the FAAS method. Interferences were minimal with both methods. The two techniques correlated satisfactorily (the correlation coefficients ranged from 0.945-0.970 among laboratories) but the colorimetric assay exhibited slightly higher results than the FAAS method. Each method was transferable among laboratories.

  6. Comparison of segmentation algorithms for fluorescence microscopy images of cells.

    PubMed

    Dima, Alden A; Elliott, John T; Filliben, James J; Halter, Michael; Peskin, Adele; Bernal, Javier; Kociolek, Marcin; Brady, Mary C; Tang, Hai C; Plant, Anne L

    2011-07-01

    The analysis of fluorescence microscopy of cells often requires the determination of cell edges. This is typically done using segmentation techniques that separate the cell objects in an image from the surrounding background. This study compares segmentation results from nine different segmentation techniques applied to two different cell lines and five different sets of imaging conditions. Significant variability in the results of segmentation was observed that was due solely to differences in imaging conditions or applications of different algorithms. We quantified and compared the results with a novel bivariate similarity index metric that evaluates the degree of underestimating or overestimating a cell object. The results show that commonly used threshold-based segmentation techniques are less accurate than k-means clustering with multiple clusters. Segmentation accuracy varies with imaging conditions that determine the sharpness of cell edges and with geometric features of a cell. Based on this observation, we propose a method that quantifies cell edge character to provide an estimate of how accurately an algorithm will perform. The results of this study will assist the development of criteria for evaluating interlaboratory comparability. Published 2011 Wiley-Liss, Inc.

  7. Typing Clostridium difficile strains based on tandem repeat sequences

    PubMed Central

    2009-01-01

    Background Genotyping of epidemic Clostridium difficile strains is necessary to track their emergence and spread. Portability of genotyping data is desirable to facilitate inter-laboratory comparisons and epidemiological studies. Results This report presents results from a systematic screen for variation in repetitive DNA in the genome of C. difficile. We describe two tandem repeat loci, designated 'TR6' and 'TR10', which display extensive sequence variation that may be useful for sequence-based strain typing. Based on an investigation of 154 C. difficile isolates comprising 75 ribotypes, tandem repeat sequencing demonstrated excellent concordance with widely used PCR ribotyping and equal discriminatory power. Moreover, tandem repeat sequences enabled the reconstruction of the isolates' largely clonal population structure and evolutionary history. Conclusion We conclude that sequence analysis of the two repetitive loci introduced here may be highly useful for routine typing of C. difficile. Tandem repeat sequence typing resolves phylogenetic diversity to a level equivalent to PCR ribotypes. DNA sequences may be stored in databases accessible over the internet, obviating the need for the exchange of reference strains. PMID:19133124

  8. Chapter 23: International Standard reagents for harmonization of HPV serology and DNA assays--an update.

    PubMed

    Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M

    2006-08-31

    International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.

  9. Rheology measurements of a biomass slurry : an inter-laboratory study

    Treesearch

    Jonathan J. Stickel; Jeffrey S. Knutsen; Matthew W. Liberatore; Wing Luu; Douglas W. Bousfield; Daniel J. Klingenberg; Tim Scott; Thatcher W. Root; Max R. Ehrhardt; Thomas O. Monz

    2009-01-01

    The conversion of biomass, specifically lignocellulosic biomass, into fuels and chemicals has recently gained national attention as an alternative to the use of fossil fuels. Increasing the concentration of the biomass solids during biochemical conversion has a large potential to reduce production costs. These concentrated biomass slurries have highly viscous, non-...

  10. More rapid edgewise crush test methods

    Treesearch

    Thomas J. Urbanik; Arthur H. Catlin; Davide R. Friedman; Richard C. Lund

    1993-01-01

    The use of paraffin wax to reinforce the loading edges of corrugated fiberboard edge-crush specimens requires that the specimens be reconditioned after waxing. The traditional practice employing a 24-h reconditioning period is a conservative approach based on the moisture response rate of corrugated containers. An interlaboratory study was conducted to determine the...

  11. Performance of the Cottonscan Instrument for Measuring the Average Fiber Linear Density (Fineness) of Cotton Lint Samples

    USDA-ARS?s Scientific Manuscript database

    This paper explores the CottonscanTM instrument, a new technology designed for routine measurement of the average linear density (fineness) of cotton fiber. A major international inter-laboratory trial of the CottonscanTM system is presented. This expands the range of cottons and laboratories fro...

  12. Interlaboratory testing of 42-d Hyalella azteca survival, growth and reproduction method with sediment and water-only exposures

    EPA Science Inventory

    Over the past four years, USEPA-Duluth, USGS-Columbia, the Illinois Natural History Survey, and Environment Canada have conducted studies to refine the USEPA/ASTM International methods for conducting 10- to 42-d water or sediment toxicity exposures with Hyalella azteca. In advanc...

  13. POSSIBLE APPROACHES FOR THE ESTABLISHMENT OF INTERLABORATORY COMPARABILITY IN THE DETERMINATION OF POLYCHLORINATED BIPHENYLS IN HUMAN SERUM

    EPA Science Inventory

    The Massachusetts Department of Public Health, with the assistance of the centers for Disease Control, conducted a study to determine the prevalence of elevated levels (>30ppb) of polychlorinated biphenyls (PCBs) in serum taken from residents of the greater New Bedford area in Ma...

  14. Interlaboratory validation of quantitative duplex real-time PCR method for screening analysis of genetically modified maize.

    PubMed

    Takabatake, Reona; Koiwa, Tomohiro; Kasahara, Masaki; Takashima, Kaori; Futo, Satoshi; Minegishi, Yasutaka; Akiyama, Hiroshi; Teshima, Reiko; Oguchi, Taichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2011-01-01

    To reduce the cost and time required to routinely perform the genetically modified organism (GMO) test, we developed a duplex quantitative real-time PCR method for a screening analysis simultaneously targeting an event-specific segment for GA21 and Cauliflower Mosaic Virus 35S promoter (P35S) segment [Oguchi et al., J. Food Hyg. Soc. Japan, 50, 117-125 (2009)]. To confirm the validity of the method, an interlaboratory collaborative study was conducted. In the collaborative study, conversion factors (Cfs), which are required to calculate the GMO amount (%), were first determined for two real-time PCR instruments, the ABI PRISM 7900HT and the ABI PRISM 7500. A blind test was then conducted. The limit of quantitation for both GA21 and P35S was estimated to be 0.5% or less. The trueness and precision were evaluated as the bias and reproducibility of the relative standard deviation (RSD(R)). The determined bias and RSD(R) were each less than 25%. We believe the developed method would be useful for the practical screening analysis of GM maize.

  15. Technical aspects and inter-laboratory variability in native peptide profiling: the CE-MS experience.

    PubMed

    Mischak, Harald; Vlahou, Antonia; Ioannidis, John P A

    2013-04-01

    Mass spectrometry platforms have attracted a lot of interest in the last 2 decades as profiling tools for native peptides and proteins with clinical potential. However, limitations associated with reproducibility and analytical robustness, especially pronounced with the initial SELDI systems, hindered the application of such platforms in biomarker qualification and clinical implementation. The scope of this article is to give a short overview on data available on performance and on analytical robustness of the different platforms for peptide profiling. Using the CE-MS platform as a paradigm, data on analytical performance are described including reproducibility (short-term and intermediate repeatability), stability, interference, quantification capabilities (limits of detection), and inter-laboratory variability. We discuss these issues by using as an example our experience with the development of a 273-peptide marker for chronic kidney disease. Finally, we discuss pros and cons and means for improvement and emphasize the need to test in terms of comparative clinical performance and impact, different platforms that pass reasonably well analytical validation tests. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PVmore » installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.« less

  17. Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David; Annigoni, Eleonora; Ballion, Amal

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PVmore » installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.« less

  18. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    Reduced strength of attachment of the encapsulant resulting from outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installationsmore » was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.« less

  19. Validation of standard method EN ISO 11290-part 2 for the enumeration of Listeria monocytogenes in food.

    PubMed

    Rollier, Patricia; Lombard, Bertrand; Guillier, Laurent; François, Danièle; Romero, Karol; Pierru, Sylvie; Bouhier, Laurence; Gnanou Besse, Nathalie

    2018-05-01

    The reference method for the detection and enumeration of L. monocytogenes in food (Standards EN ISO 11290-1&2) have been validated by inter-laboratory studies in the frame of the Mandate M381 from European Commission to CEN. In this paper, the inter-laboratory studies led in 2013 on 5 matrices (cold-smoked salmon, milk powdered infant food formula, vegetables, environment, and cheese) to validate Standard EN ISO 11290-2 are reported. According to the results obtained, the method of the revised Standard EN ISO 11290-2 can be considered as a good method for the enumeration of L. monocytogenes in foods and food processing environment, in particular for the matrices included in the study. Values of repeatability and reproducibility standard deviations can be considered satisfactory for this type of method with a confirmation stage, since most of them were below 0.3 log 10 , also at low levels, close to the regulatory limit of 100 CFU/g. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Validation of a two-generational reproduction test in Daphnia magna: An interlaboratory exercise.

    PubMed

    Barata, Carlos; Campos, Bruno; Rivetti, Claudia; LeBlanc, Gerald A; Eytcheson, Stephanie; McKnight, Stephanie; Tobor-Kaplon, Marysia; de Vries Buitenweg, Selinda; Choi, Suhyon; Choi, Jinhee; Sarapultseva, Elena I; Coutellec, Marie-Agnès; Coke, Maïra; Pandard, Pascal; Chaumot, Arnaud; Quéau, Hervé; Delorme, Nicolas; Geffard, Olivier; Martínez-Jerónimo, Fernando; Watanabe, Haruna; Tatarazako, Norihisa; Lopes, Isabel; Pestana, João L T; Soares, Amadeu M V M; Pereira, Cecilia Manuela; De Schamphelaere, Karel

    2017-02-01

    Effects observed within one generation disregard potential detrimental effects that may appear across generations. Previously we have developed a two generation Daphnia magna reproduction test using the OECD TG 211 protocol with a few amendments, including initiating the second generation with third brood neonates produced from first generation individuals. Here we showed the results of an inter-laboratory calibration exercise among 12 partners that aimed to test the robustness and consistency of a two generation Daphnia magna reproduction test. Pyperonyl butoxide (PBO) was used as a test compound. Following experiments, PBO residues were determined by TQD-LC/MS/MS. Chemical analysis denoted minor deviations of measured PBO concentrations in freshly prepared and old test solutions and between real and nominal concentrations in all labs. Other test conditions (water, food, D. magna clone, type of test vessel) varied across partners as allowed in the OECD test guidelines. Cumulative fecundity and intrinsic population growth rates (r) were used to estimate "No observed effect concentrations "NOEC using the solvent control as the control treatment. EC 10 and EC- 50 values were obtained regression analyses. Eleven of the twelve labs succeeded in meeting the OECD criteria of producing >60 offspring per female in control treatments during 21days in each of the two consecutive generations. Analysis of variance partitioning of cumulative fecundity indicated a relatively good performance of most labs with most of the variance accounted for by PBO (56.4%) and PBO by interlaboratory interactions (20.2%), with multigenerational effects within and across PBO concentrations explaining about 6% of the variance. EC 50 values for reproduction and population growth rates were on average 16.6 and 20.8% lower among second generation individuals, respectively. In summary these results suggest that the proposed assay is reproducible but cumulative toxicity in the second generation cannot reliably be detected with this assay. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Interlaboratory validation of the modified murine local lymph node assay based on adenosine triphosphate measurement.

    PubMed

    Omori, Takashi; Idehara, Kenji; Kojima, Hajime; Sozu, Takashi; Arima, Kazunori; Goto, Hirohiko; Hanada, Tomohiko; Ikarashi, Yoshiaki; Inoda, Taketo; Kanazawa, Yukiko; Kosaka, Tadashi; Maki, Eiji; Morimoto, Takashi; Shinoda, Shinsuke; Shinoda, Naoki; Takeyoshi, Masahiro; Tanaka, Masashi; Uratani, Mamoru; Usami, Masahito; Yamanaka, Atsushi; Yoneda, Tomofumi; Yoshimura, Isao; Yuasa, Atsuko

    2008-01-01

    The murine local lymph node assay (LLNA) is a well-established alternative to the guinea pig maximization test (GPMT) or Buehler test (BT) for the assessment of the skin sensitizing ability of drugs and chemicals. Daicel Chemical Industries Ltd. has developed a modified LLNA based on the adenosine triphosphate (ATP) content (LLNA-DA). We conducted 2 interlaboratory validation studies to evaluate the reliability and relevance of LLNA-DA. The experiment involved 17 laboratories, wherein 14 chemicals were examined under blinded conditions. In the first study, 3 chemicals were examined in 10 laboratories and the remaining 9 were examined in 3 laboratories. In the second study, 1 chemical was examined in 7 laboratories and the remaining 4 chemicals were examined in 4 laboratories. The data were expressed as the ATP content for each chemical-treated group, and the stimulation index (SI) for each chemical-treated group was determined as the increase in the ATP content relative to the concurrent vehicle control group. An SI of 3 was set as the cut-off value for exhibiting skin sensitization activity. The results of the first study obtained in the experiments conducted for the 3 chemicals that were examined in all the 10 laboratories and for 5 of the remaining 9 chemicals were sufficiently consistent with small variations in their SI values. The sensitivity, specificity, and accuracy of LLNA-DA against those of GPMT/BT were 7/8 (87.5%), 3/3 (100%), and 10/11 (90.9%), respectively. In the second study, all the 5 chemicals studied demonstrated acceptably small interlaboratory variations. In the first study, a large variation was observed for 2 chemicals; in the second study, this variation was small. It was attributed to the application of dimethylsulfoxide as the solvent for the metallic salts. In conclusion, these 2 studies provide good evidence for the reliability of the LLNA-DA.

  2. Acid-Soluble Internal Capsules for Closed-Face Cassette Elemental Sampling and Analysis of Workplace Air

    PubMed Central

    Harper, Martin; Ashley, Kevin

    2013-01-01

    Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, interlaboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements. PMID:23548078

  3. Trueness and precision of the real-time RT-PCR method for quantifying the chronic bee paralysis virus genome in bee homogenates evaluated by a comparative inter-laboratory study.

    PubMed

    Schurr, Frank; Cougoule, Nicolas; Rivière, Marie-Pierre; Ribière-Chabert, Magali; Achour, Hamid; Ádám, Dán; Castillo, Carlos; de Graaf, Dirk C; Forsgren, Eva; Granato, Anna; Heinikainen, Sirpa; Jurovčíková, Júlia; Kryger, Per; Manson, Christine; Ménard, Marie-Françoise; Perennes, Stéphane; Schäfer, Marc O; Ibañez, Elena San Miguel; Silva, João; Gajger, Ivana Tlak; Tomkies, Victoria; Toplak, Ivan; Viry, Alain; Zdańska, Dagmara; Dubois, Eric

    2017-10-01

    The Chronic bee paralysis virus (CBPV) is the aetiological agent of chronic bee paralysis, a contagious disease associated with nervous disorders in adult honeybees leading to massive mortalities in front of the hives. Some of the clinical signs frequently reported, such as trembling, may be confused with intoxication syndromes. Therefore, laboratory diagnosis using real-time PCR to quantify CBPV loads is used to confirm disease. Clinical signs of chronic paralysis are usually associated with viral loads higher than 10 8 copies of CBPV genome copies per bee (8 log 10 CBPV/bee). This threshold is used by the European Union Reference Laboratory for Bee Health to diagnose the disease. In 2015, the accuracy of measurements of three CBPV loads (5, 8 and 9 log 10 CBPV/bee) was assessed through an inter-laboratory study. Twenty-one participants, including 16 European National Reference Laboratories, received 13 homogenates of CBPV-infected bees adjusted to the three loads. Participants were requested to use the method usually employed for routine diagnosis. The quantitative results (n=270) were analysed according to international standards NF ISO 13528 (2015) and NF ISO 5725-2 (1994). The standard deviations of measurement reproducibility (S R ) were 0.83, 1.06 and 1.16 at viral loads 5, 8 and 9 log 10 CBPV/bee, respectively. The inter-laboratory confidence of viral quantification (+/- 1.96S R ) at the diagnostic threshold (8 log 10 CBPV/bee) was+/- 2.08 log 10 CBPV/bee. These results highlight the need to take into account the confidence of measurements in epidemiological studies using results from different laboratories. Considering this confidence, viral loads over 6 log 10 CBPV/bee may be considered to indicate probable cases of chronic paralysis. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  5. Comet assay in reconstructed 3D human epidermal skin models--investigation of intra- and inter-laboratory reproducibility with coded chemicals.

    PubMed

    Reus, Astrid A; Reisinger, Kerstin; Downs, Thomas R; Carr, Gregory J; Zeller, Andreas; Corvi, Raffaella; Krul, Cyrille A M; Pfuhler, Stefan

    2013-11-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure.

  6. Inter-laboratory exercise on antibiotic drugs analysis in aqueous samples.

    PubMed

    Roig, B; Brogat, M; Mompelat, S; Leveque, J; Cadiere, A; Thomas, O

    2012-08-30

    An inter-laboratory exercise was organized under the PHARMAS EU project, by the Advanced School of Public Health (EHESP), in order to evaluate the performances of analytical methods for the measurement of antibiotics in waters (surface and tap). This is the first time such an exercise on antibiotics has been organized in Europe, using different kinds of analytical methods and devices. In this exercise thirteen laboratories from five countries (Canada, France, Italy, the Netherlands and Portugal) participated, and a total number of 78 samples were distributed. During the exercise, 2 testing samples (3 bottles of each) prepared from tap water and river water, respectively, spiked with antibiotics, were sent to participants and analyzed over a period of one month. A final number of 77 (98.7%) testing samples were considered. Depending on substances studied by each participant, 305 values in duplicate were collected, with the results for each sample being expressed as the target concentration. A statistical study was initiated using 611 results. The mean value, standard deviation, coefficient of variation, standard uncertainty of the mean, median, the minimum and maximum values of each series as well as the 95% confidence interval were obtained from each participant laboratory. In this exercise, 36 results (6% of accounted values) were outliers according to the distribution over the median (box plot). The outlier results were excluded. In order to establish the stability of testing samples in the course of the exercise, differences between variances obtained for every type of sample at different intervals were evaluated. The results showed no representative variations and it can be considered that all samples were stable during the exercise. The goals of this inter-laboratory study were to assess results variability when analysis is conducted by different laboratories, to evaluate the influence of different matrix samples, and to determine the rate at which participating laboratories successfully completed the tests initiated. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Comet assay in reconstructed 3D human epidermal skin models—investigation of intra- and inter-laboratory reproducibility with coded chemicals

    PubMed Central

    Pfuhler, Stefan

    2013-01-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure. PMID:24150594

  8. Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise.

    PubMed

    Bolognesi, Claudia; Knasmueller, Siegfried; Nersesyan, Armen; Roggieri, Paola; Ceppi, Marcello; Bruzzone, Marco; Blaszczyk, Ewa; Mielzynska-Svach, Danuta; Milic, Mirta; Bonassi, Stefano; Benedetti, Danieli; Da Silva, Juliana; Toledo, Raphael; Salvadori, Daisy Maria Fávero; Groot de Restrepo, Helena; Filipic, Metka; Hercog, Klara; Aktas, Ayça; Burgaz, Sema; Kundi, Michael; Grummt, Tamara; Thomas, Philip; Hor, Maryam; Escudero-Fung, Maria; Holland, Nina; Fenech, Michael

    2017-03-01

    The buccal micronucleus cytome (BMNcyt) assay in uncultured exfoliated epithelial cells from oral mucosa is widely applied in biomonitoring human exposures to genotoxic agents and is also proposed as a suitable test for prescreening and follow-up of precancerous oral lesions. The main limitation of the assay is the large variability observed in the baseline values of micronuclei (MNi) and other nuclear anomalies mainly related to different scoring criteria. The aim of this international collaborative study, involving laboratories with different level of experience, was to evaluate the inter- and intra-laboratory variations in the BMNcyt parameters, using recently implemented guidelines, in scoring cells from the same pooled samples obtained from healthy subjects (control group) and from cancer patients undergoing radiotherapy (treated group). The results indicate that all laboratories correctly discriminated samples from the two groups by a significant increase of micronucleus (MN) and nuclear bud (NBUD) frequencies and differentiated binucleated (BN) cells, associated with the exposure to ionizing radiation. The experience of the laboratories was shown to play an important role in the identification of the different cell types and nuclear anomalies. MN frequency in differentiated mononucleated (MONO) and BN cells showed the greatest consistency among the laboratories and low variability was also detected in the frequencies of MONO and BN cells. A larger variability was observed in classifying the different cell types, indicating the subjectivity in the interpretation of some of the scoring criteria while reproducibility of the results between scoring sessions was very good. An inter-laboratory calibration exercise is strongly recommended before starting studies with BMNcyt assay involving multiple research centers. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Total Mercury in Surface and Deep Waters in the Western and Eastern Mediterranean Sea

    NASA Astrophysics Data System (ADS)

    Varde', M.; Cofone, F.; Servidio, A.; Rosselli, A.; Hedgecock, I. M.; Ammoscato, I.; Mannarino, V.; Sprovieri, F.; Gensini, M.; Pirrone, N.

    2014-12-01

    In the framework of the Italian National Research Council (CNR) Med-Oceanor measurement program and as part of the Global Mercury Observation System (GMOS) objectives, we performed two cruise campaigns with the CNR's Research Vessel (RV) Urania, in the western and eastern Mediterranean Basin, in the summers of 2012 and 2013. Total Mercury (THg) concentration in seawater was systematically measured at different depths from the sea bottom to the surface. A total of 155 surface and deep seawater samples at 25 selected stations were collected during the cruise campaigns using a stainless-steel rosette system on which 24 Niskin bottles (10L) were mounted. Continuous monitoring of temperature, conductivity, salinity and oxygen with depth were obtained by CTD measurements. All fluorinated containers were cleaned prior to use following GMOS SOPs. The chemical reagents used were suitable for ultra-trace Hg analysis. After sampling, samples were preserved by adding HCl solution to the sample bottles, which were refrigerated during transportation and analyzed within four weeks of the end of the oceanographic campaign. Sea water samples were analyzed in the laboratory following the US-EPA 1631 method revision E (US-EPA, 2002). To assess the critical issues related to mercury (Hg) contamination and to prevent leakage of Hg through volatilization we used all necessary precautions for sampling, sample stabilization, preservation and subsequent analysis in the laboratory. Quality assurance and quality control were performed using transport blanks, laboratory blanks and use of seawater certified reference materials. The accuracy of the analytical procedures for the determination of THg in sea water was corroborated by participation in a global inter-laboratory comparison study for THg in natural waters. THg concentrations in surface and deep waters found in the Mediterranean basin during the last two cruise campaigns Med-Oceanor as well as the THg measurements in sea water collected in the other programs and oceanographic campaigns will help to further our understanding of Hg marine distribution and its impact on the biogeochemical cycle of Hg in the open ocean.

  10. A conversion of CO2-ECBM related lab observations to reservoir requirements

    NASA Astrophysics Data System (ADS)

    Gensterblum, Y.; Merkel, A.; Busch, A.; Krooss, B. M.

    2012-04-01

    To predict a CBM production profile either during primary or secondary production, aspects like coal permeability and porosity, density, ash and moisture content, initial gas-in-place (GIP) (from canister desorption tests), gas sorption capacity from laboratory isotherms (to obtain gas saturations and desorption pressure), gas diffusivities, coal volumetrics (thickness and areal extent) need to be understood as a minimum requirement. When dealing with CO2-ECBM selective adsorption, counter diffusion in the coal matrix, or coal shrinkage and swelling (from CH4 desorption and CO2 adsorption, respectively) and the influence of moisture need to be investigated in addition to the parameters above. During CO2-ECBM processes, the areal distribution of the CO2 injected is accomplished by flow through the cleat network. When CO2 is entering the coal matrix by a combined sorption/diffusion process it will adsorb to the coal inner surface and at the same time replace part of the CH4. This replacement occurs either by a reduction in the CH4 partial pressure or by a higher selective sorption of CO2 over CH4. Because of a concentration gradient between CH4 in the matrix compared to the cleat system, CH4 diffuses from the coal matrix into the cleat system where, by pressure drawdown towards a production well, it can be produced. In this context this presentation summarizes gas (CO2, CH4) and water sorption on coal and specifically addresses the following topics: • CH4 and CO2 sorption capacity as a function depth and rank • CO2 and CH4 sorption on natural coals and its dependence on coal specific parameters like coal rank, maceral composition or ash content (Busch and Gensterblum, 2011). • Water sorption on coal, its dependence on coal properties such as rank and coal chemistry and gas sorption in the presence of water (Busch and Gensterblum, 2011). • N2, CH4, CO2 displacement experiments and the volumetric response of the coal on the present gas type (sorbing or inert) in the pore system • Uncertainties in reservoir characterisation (Gensterblum et al., 2010; Gensterblum et al., 2009) • Sorption uptake kinetic as a function of surface coverage and the influence of moisture on the kinetic Busch, A. and Gensterblum, Y., 2011. CBM and CO2-ECBM related sorption processes in coal: A review. International Journal of Coal Geology, 87: 49-71. Gensterblum, Y. et al., 2010. European inter-laboratory comparison of high pressure CO2 sorption isotherms II: Natural coals. International Journal of Coal Geology, 84(2): 115-124. Gensterblum, Y. et al., 2009. European inter-laboratory comparison of high pressure CO2 sorption isotherms. I: Activated carbon. Carbon, 47(13): 2958-2969.

  11. Saccadic Reaction Times in Infants and Adults: Spatiotemporal Factors, Gender, and Interlaboratory Variation

    ERIC Educational Resources Information Center

    Kenward, Ben; Koch, Felix-Sebastian; Forssman, Ida; Brehm, Julia; Tidemann, Linda; Sundqvist, Annette; Marciszkom, Carin; Hermansen, Tone Kristine; Heimann, Mikael; Gredebäck, Gustaf

    2017-01-01

    Saccade latency is widely used across infant psychology to investigate infants' understanding of events. Interpreting particular latency values requires knowledge of standard saccadic RTs, but there is no consensus as to typical values. This study provides standard estimates of infants' (n = 194, ages 9 to 15 months) saccadic RTs under a range of…

  12. An inter-laboratory study on the variability in measured concentrations of 17Beta-estradiol, testosterone and 11-ketotestosterone in white sucker: implications and recommendations

    EPA Science Inventory

    Endocrine-disrupting chemicals (EDCs) are exogenous substances that can lead to impacts on the reproduction of fish sometimes by altering circulating concentrations of 17â-estradiol (E2), testosterone (T) and 11-ketotestosterone (11-KT). Common methods to measure steroids in pla...

  13. 40 CFR Appendix D to Part 136 - Precision and Recovery Statements for Methods for Measuring Metals

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Accuracy Section with the following: Precision and Accuracy An interlaboratory study on metal analyses by... details are found in “USEPA Method Study 7, Analyses for Trace Methods in water by Atomic Absorption... study on metal analyses by this method was conducted by the Quality Assurance Branch (QAB) of the...

  14. Evaluation of nutrient quality-assurance data for Alexanders and Mount Rock Spring basins, Cumberland County, Pennsylvania

    USGS Publications Warehouse

    Witt, E. C.; Hippe, D.J.; Giovannitti, R.M.

    1992-01-01

    A total of 304 nutrient samples were collected from May 1990 through September 1991 to determine concentrations and loads of nutrients in water discharged from two spring basins in Cumberland County, Pa. Fifty-four percent of these nutrient samples were for the evaluation of (1) laboratory consistency, (2) container and preservative cleanliness, (3) maintenance of analyte representativeness as affected by three different preservation methods, and (4) comparison of analyte results with the "Most Probable Value" for Standard Reference Water Samples. Results of 37 duplicate analyses indicate that the Pennsylvania Department of Environmental Resources, Bureau of Laboratories (principal laboratory) remained within its ±10 percent goal for all but one analyte. Results of the blank analysis show that the sampling containers did not compromise the water quality. However, mercuric-chloride-preservation blanks apparently contained measurable ammonium in four of five samples and ammonium plus organic nitrogen in two of five samples. Interlaboratory results indicate substantial differences in the determination of nitrate and ammonium plus organic nitrogen between the principal laboratory and the U.S. Geological Survey National Water-Quality Laboratory. In comparison with the U.S. Environmental Protection Agency Quality-Control Samples, the principal laboratory was sufficiently accurate in its determination of nutrient anafytes. Analysis of replicate samples indicated that sulfuric-acid preservative best maintained the representativeness of the anafytes nitrate and ammonium plus organic nitrogen, whereas, mercuric chloride best maintained the representativeness of orthophosphate. Comparison of nutrient analyte determinations with the Most Probable Value for each preservation method shows that two of five analytes with no chemical preservative compare well, three of five with mercuric-chloride preservative compare well, and three of five with sulfuricacid preservative compare well.

  15. Interlaboratory validation of an improved U.S. Food and Drug Administration method for detection of Cyclospora cayetanensis in produce using TaqMan real-time PCR

    USDA-ARS?s Scientific Manuscript database

    A collaborative validation study was performed to evaluate the performance of a new U.S. Food and Drug Administration method developed for detection of the protozoan parasite, Cyclospora cayetanensis, on cilantro and raspberries. The method includes a sample preparation step in which oocysts are re...

  16. Interlaboratory calibration of atmospheric nitrous oxide measurements

    NASA Technical Reports Server (NTRS)

    Rasmussen, R. A.; Pierotti, D.

    1978-01-01

    Samples representative of Northern Hemispheric conditions in mid-1976 were analyzed by 11 laboratories to resolve the question of the absolute tropospheric concentration of nitrous oxide. The laboratories all employed electron capture-gas chromatography for the analysis. After exclusion of one anomalously low determination, the calibration results showed a mean concentration of 323.5 + or - 8.7 ppb v/v nitrous oxide.

  17. Inter-laboratory validation of an inexpensive streamlined method to measure inorganic arsenic in rice grain

    USDA-ARS?s Scientific Manuscript database

    With the establishment by CODEX of a 200 ng/g limit of inorganic arsenic (iAs) in polished rice grain, more analyses of iAs will be necessary to ensure compliance in regulatory and trade applications, to assess quality control in commercial rice production, and to conduct research involving iAs in r...

  18. INTERLABORATORY EVALUATION OF MI AGAR AND THE US ENVIRONMENTAL PROTECTION AGENCY-APPROVED MEMBRANE FILTER METHOD FOR THE RECOVERY OF TOTAL COLIFORMS AND ESCHERICHIA COLI FROM DRINKING WATER

    EPA Science Inventory

    A new membrane filter (MF) medium, MI agar, recently validated for use in recovering chlorine-damaged total coloiforms (TC) and Escherichia coli from drinking water, was compared to the US Environmental Protection Agency (EPA)-approved MF method(mEndo agar and nutrient agar suppl...

  19. Development and Interlaboratory Validation of a Simple Screening Method for Genetically Modified Maize Using a ΔΔC(q)-Based Multiplex Real-Time PCR Assay.

    PubMed

    Noguchi, Akio; Nakamura, Kosuke; Sakata, Kozue; Sato-Fukuda, Nozomi; Ishigaki, Takumi; Mano, Junichi; Takabatake, Reona; Kitta, Kazumi; Teshima, Reiko; Kondo, Kazunari; Nishimaki-Mogami, Tomoko

    2016-04-19

    A number of genetically modified (GM) maize events have been developed and approved worldwide for commercial cultivation. A screening method is needed to monitor GM maize approved for commercialization in countries that mandate the labeling of foods containing a specified threshold level of GM crops. In Japan, a screening method has been implemented to monitor approved GM maize since 2001. However, the screening method currently used in Japan is time-consuming and requires generation of a calibration curve and experimental conversion factor (C(f)) value. We developed a simple screening method that avoids the need for a calibration curve and C(f) value. In this method, ΔC(q) values between the target sequences and the endogenous gene are calculated using multiplex real-time PCR, and the ΔΔC(q) value between the analytical and control samples is used as the criterion for determining analytical samples in which the GM organism content is below the threshold level for labeling of GM crops. An interlaboratory study indicated that the method is applicable independently with at least two models of PCR instruments used in this study.

  20. Progress in Quantitative Viral Load Testing: Variability and Impact of the WHO Quantitative International Standards

    PubMed Central

    Sun, Y.; Tang, L.; Procop, G. W.; Hillyard, D. R.; Young, S. A.; Caliendo, A. M.

    2016-01-01

    ABSTRACT It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log10 copies/ml and the overall range for a given sample up to 5.66 log10 copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses. PMID:27852673

  1. The Development of a Novel, Validated, Rapid and Simple Method for the Detection of Sarcocystis fayeri in Horse Meat in the Sanitary Control Setting.

    PubMed

    Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro

    2016-01-01

    Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.

  2. Examination of a size-change test for photovoltaic encapsulation materials

    NASA Astrophysics Data System (ADS)

    Miller, David C.; Gu, Xiaohong; Ji, Liang; Kelly, George; Nickel, Nichole; Norum, Paul; Shioda, Tsuyoshi; Tamizhmani, Govindasamy; Wohlgemuth, John H.

    2012-10-01

    We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International Electrotechnical Commission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sand substrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/-5°C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). The test procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/-5% between laboratories.

  3. Tendency for interlaboratory precision in the GMO analysis method based on real-time PCR.

    PubMed

    Kodama, Takashi; Kurosawa, Yasunori; Kitta, Kazumi; Naito, Shigehiro

    2010-01-01

    The Horwitz curve estimates interlaboratory precision as a function only of concentration, and is frequently used as a method performance criterion in food analysis with chemical methods. The quantitative biochemical methods based on real-time PCR require an analogous criterion to progressively promote method validation. We analyzed the tendency of precision using a simplex real-time PCR technique in 53 collaborative studies of seven genetically modified (GM) crops. Reproducibility standard deviation (SR) and repeatability standard deviation (Sr) of the genetically modified organism (GMO) amount (%) was more or less independent of GM crops (i.e., maize, soybean, cotton, oilseed rape, potato, sugar beet, and rice) and evaluation procedure steps. Some studies evaluated whole steps consisting of DNA extraction and PCR quantitation, whereas others focused only on the PCR quantitation step by using DNA extraction solutions. Therefore, SR and Sr for GMO amount (%) are functions only of concentration similar to the Horwitz curve. We proposed S(R) = 0.1971C 0.8685 and S(r) = 0.1478C 0.8424, where C is the GMO amount (%). We also proposed a method performance index in GMO quantitative methods that is analogous to the Horwitz Ratio.

  4. Bulletin of the Division of Electrical Engineering, 1987-1988, volume 3, number 2

    NASA Astrophysics Data System (ADS)

    1988-05-01

    A report is provided on the activities of the Division of Electrical Engineering of the National Research Council of Canada. The Division engages in the development of standards and test procedures, and undertakes applied research in support of Canadian industry, government departments, and universities. Technology transfer and collaborative research continue to grow in importance as focuses of Division activities. The Division is comprised of three sections: the Laboratory for Biomedical Engineering, the Laboratory for Electromagnetic and Power Engineering, and the Laboratory for Intelligent Systems. An agreement has been reached to commercially exploit the realtime multiprocessor operating system Harmony. The dielectrics group has made contract research agreements with industry from both Canada and the United States. The possibility of employing a new advanced laser vision camera, which can be mounted on a robot arm in a variety of industrial applications is being explored. Potential short-term spinoffs related to intelligent wheelchairs are being sought as part of the new interlaboratory program which has as its long-term objective the development of a mobile robot for health care applications. A program in applied artificial intelligence has been established. Initiatives in collaboration with outside groups include proposals for major institutes in areas ranging from police and security research to rehabilitation research, programs to enhance Canadian industrial competence working with the Canadian Manufacturers' Association and other government departments, and approaches to the utilization of existing facilities which will make them more valuable without significant financial expenditures.

  5. Simultaneous analysis of cerebrospinal fluid biomarkers using microsphere-based xMAP multiplex technology for early detection of Alzheimer's disease.

    PubMed

    Kang, Ju-Hee; Vanderstichele, Hugo; Trojanowski, John Q; Shaw, Leslie M

    2012-04-01

    The xMAP-Luminex multiplex platform for measurement of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers using Innogenetics AlzBio3 immunoassay reagents that are for research use only has been shown to be an effective tool for early detection of an AD-like biomarker signature based on concentrations of CSF Aβ(1-42), t-tau and p-tau(181). Among the several advantages of the xMAP-Luminex platform for AD CSF biomarkers are: a wide dynamic range of ready-to-use calibrators, time savings for the simultaneous analyses of three biomarkers in one analytical run, reduction of human error, potential of reduced cost of reagents, and a modest reduction of sample volume as compared to conventional enzyme-linked immunosorbant assay (ELISA) methodology. Recent clinical studies support the use of CSF Aβ(1-42), t-tau and p-tau(181) measurement using the xMAP-Luminex platform for the early detection of AD pathology in cognitively normal individuals, and for prediction of progression to AD dementia in subjects with mild cognitive impairment (MCI). Studies that have shown the prediction of risk for progression to AD dementia by MCI patients provide the basis for the use of CSF Aβ(1-42), t-tau and p-tau(181) testing to assign risk for progression in patients enrolled in therapeutic trials. Furthermore emerging study data suggest that these pathologic changes occur in cognitively normal subjects 20 or more years before the onset of clinically detectable memory changes thus providing an objective measurement for use in the assessment of treatment effects in primary treatment trials. However, numerous previous ELISA and Luminex-based multiplex studies reported a wide range of absolute values of CSF Aβ(1-42), t-tau and p-tau(181) indicative of substantial inter-laboratory variability as well as varying degrees of intra-laboratory imprecision. In order to address these issues a recent inter-laboratory investigation that included a common set of CSF pool aliquots from controls as well as AD patients over a range of normal and pathological Aβ(1-42), t-tau and p-tau(181) values as well as agreed-on standard operating procedures (SOPs) assessed the reproducibility of the multiplex methodology and Innogenetics AlzBio3 immunoassay reagents. This study showed within-center precision values of 5% to a little more than 10% and good inter-laboratory %CV values (10-20%). There are several likely factors influencing the variability of CSF Aβ(1-42), t-tau and p-tau(181) measurements. In this review, we describe the pre-analytical, analytical and post-analytical sources of variability including sources inherent to kits, and describe procedures to decrease the variability. A CSF AD biomarker Quality Control program has been established and funded by the Alzheimer Association, and global efforts are underway to further define optimal pre-analytical SOPs and best practices for the methodologies available or in development including plans for production of a standard reference material that could provide for a common standard against which manufacturers of immunoassay kits would assign calibration standard values. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.

    PubMed

    Carter, J F; Fry, B

    2013-03-01

    The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.

  7. Progress in the analysis and interpretation of N2O isotopes: Potential and future challenges

    NASA Astrophysics Data System (ADS)

    Mohn, Joachim; Tuzson, Béla; Zellweger, Christoph; Harris, Eliza; Ibraim, Erkan; Yu, Longfei; Emmenegger, Lukas

    2017-04-01

    In recent years, research on nitrous oxide (N2O) stable isotopes has significantly advanced, addressing an increasing number of research questions in biogeochemical and atmospheric sciences [1]. An important milestone was the development of quantum cascade laser based spectroscopic devices [2], which are inherently specific for structural isomers (15N14N16O vs. 14N15N16O) and capable to collect real-time data with high temporal resolution, complementary to the well-established isotope-ratio mass-spectrometry (IRMS) method. In combination with automated preconcentration, optical isotope ratio spectroscopy (OIRS) has been applied to disentangle source processes in suburban, rural and pristine environments [e.g. 3, 4]. Within the European Metrology Research Programme (EMRP) ENV52 project "Metrology for high-impact greenhouse gases (HIGHGAS)", the quality of N2O stable isotope analysis by OIRS, the comparability between laboratories, and the traceability to the international isotope ratio scales have been addressed. An inter-laboratory comparison between eleven IRMS and OIRS laboratories, organised within HIGHGAS, indicated limited comparability for 15N site preference, i.e. the difference between 15N abundance in central (N*NO) and end (*NNO) position [5]. In addition, the accuracy of the NH4NO3 decomposition reaction, which provides the link between 15N site preference and the international 15N/14N scale, was found to be limited by non-quantitative NH4NO3 decomposition in combination with substantially different isotope enrichment factors for both nitrogen atoms [6]. Results of the HIGHGAS project indicate that the following research tasks have to be completed to foster research on N2O isotopes: 1) develop improved techniques to link the 15N and 18O abundance and the 15N site preference in N2O to the international stable isotope ratio scales; 2) provide N2O reference materials, pure and diluted in an air matrix, to improve inter-laboratory compatibility. These tasks will be addressed in the upcoming European Metrology Programme for Innovation and Research (EMPIR) project "Metrology for Stable Isotope Reference Standards (SIRS)" starting in June 2017. Acknowledgement Part of this work has been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] S. Toyoda et al., Isotopocule analysis of biologically produced nitrous oxide in various environments, Mass Spectrom. Rev., Doi 10.1002/mas.21459 (2015). [2] J. Mohn et al., Site selective real-time measurements of atmospheric N2O isotopomers by laser spectroscopy, Atmos. Meas. Tech. 5(7), 1601-1609 (2012). [3] B. Wolf et al., First on-line isotopic characterization of N2O above intensively managed grassland, Biogeosci. 12, 2517-2531, (2015). [4] E. Harris et al., Tracking nitrous oxide emission processes at a suburban site with semi-continuous, in-situ measurements of isotopic composition, J. Geophys. Res. Atmos., accepted (2016). [5] J. Mohn et al., Interlaboratory assessment of nitrous oxide isotopomer analysis by isotope ratio mass spectrometry and laser spectroscopy: current status and perspectives, Rapid Commun. Mass Spectrom. 28, 1995-2007 (2014). [6] J. Mohn et al. Reassessment of the NH4NO3 thermal decomposition technique for calibration of the N2O isotopic composition, Rapid Commun. Mass Spectrom. 30, 2487-2496 (2016).

  8. ISOS-3 Inter-Laboratory Collaboration Focused on the Stability of a Variety of Organic Photovoltaic Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanenbaum, D. M.; Hermenau, M.; Voroshazi, E.

    2012-02-07

    Seven distinct sets (n {>=} 12) of state of the art organic photovoltaic devices were prepared by leading research laboratories in a collaboration planned at the Third International Summit on Organic Photovoltaic Stability (ISOS-3). All devices were shipped to RISO DTU and characterized simultaneously up to 1830 h in accordance with established ISOS-3 protocols under three distinct illumination conditions: accelerated full sun simulation; low level indoor fluorescent lighting; and dark storage with daily measurement under full sun simulation. Three nominally identical devices were used in each experiment both to provide an assessment of the homogeneity of the samples and tomore » distribute samples for a variety of post soaking analytical measurements at six distinct laboratories enabling comparison at various stages in the degradation of the devices. Over 100 devices with more than 300 cells were used in the study. We present here design and fabrication details for the seven device sets, benefits and challenges associated with the unprecedented size of the collaboration, characterization protocols, and results both on individual device stability and uniformity of device sets, in the three illumination conditions.« less

  9. Accuracy investigation of phthalate metabolite standards.

    PubMed

    Langlois, Éric; Leblanc, Alain; Simard, Yves; Thellen, Claude

    2012-05-01

    Phthalates are ubiquitous compounds whose metabolites are usually determined in urine for biomonitoring studies. Following suspect and unexplained results from our laboratory in an external quality-assessment scheme, we investigated the accuracy of all phthalate metabolite standards in our possession by comparing them with those of several suppliers. Our findings suggest that commercial phthalate metabolite certified solutions are not always accurate and that lot-to-lot discrepancies significantly affect the accuracy of the results obtained with several of these standards. These observations indicate that the reliability of the results obtained from different lots of standards is not equal, which reduces the possibility of intra-laboratory and inter-laboratory comparisons of results. However, agreements of accuracy have been observed for a majority of neat standards obtained from different suppliers, which indicates that a solution to this issue is available. Data accuracy of phthalate metabolites should be of concern for laboratories performing phthalate metabolite analysis because of the standards used. The results of our investigation are presented from the perspective that laboratories performing phthalate metabolite analysis can obtain accurate and comparable results in the future. Our findings will contribute to improving the quality of future phthalate metabolite analyses and will affect the interpretation of past results.

  10. Trace-element composition of Chicxulub crater melt rock, K/T tektites and Yucatan basement

    NASA Technical Reports Server (NTRS)

    Hildebrand, A. R.; Gregoire, D. C.; Attrep, M., Jr.; Claeys, P.; Thompson, C. M.; Boynton, W. V.

    1993-01-01

    The Cretaceous/Tertiary (K/T) boundary Chicxulub impact is the best preserved large impact in the geologic record. The Chicxulub crater has been buried with no apparent erosion of its intracrater deposits, and its ejecta blanket is known and is well preserved at hundreds of localities globally. Although most of the molten material ejected from the crater has been largely altered, a few localities still preserve tektite glass. Availability of intra- and extracrater impact products as well as plausible matches to the targeted rocks allows the comparison of compositions of the different classes of impact products to those of the impacted lithologies. Determination of trace-element compositions of the K/T tektites, Chicxulub melt rock, and the targeted Yucatan silicate basement and carbonate/evaporite lithologies have been made using instrumental neutron activation analysis (INAA) and inductively coupled plasma mass spectrometry (ICP-MS). Some sample splits were studied with both techniques to ensure that inter-laboratory variation was not significant or could be corrected. The concentration of a few major and minor elements was also checked against microprobe results. Radiochemical neutron activation analysis (RNAA) was used to determine Ir abundances in some samples.

  11. RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA).

    PubMed

    Oestreicher, Ursula; Samaga, Daniel; Ainsbury, Elizabeth; Antunes, Ana Catarina; Baeyens, Ans; Barrios, Leonardo; Beinke, Christina; Beukes, Philip; Blakely, William F; Cucu, Alexandra; De Amicis, Andrea; Depuydt, Julie; De Sanctis, Stefania; Di Giorgio, Marina; Dobos, Katalin; Dominguez, Inmaculada; Duy, Pham Ngoc; Espinoza, Marco E; Flegal, Farrah N; Figel, Markus; Garcia, Omar; Monteiro Gil, Octávia; Gregoire, Eric; Guerrero-Carbajal, C; Güçlü, İnci; Hadjidekova, Valeria; Hande, Prakash; Kulka, Ulrike; Lemon, Jennifer; Lindholm, Carita; Lista, Florigio; Lumniczky, Katalin; Martinez-Lopez, Wilner; Maznyk, Nataliya; Meschini, Roberta; M'kacher, Radia; Montoro, Alegria; Moquet, Jayne; Moreno, Mercedes; Noditi, Mihaela; Pajic, Jelena; Radl, Analía; Ricoul, Michelle; Romm, Horst; Roy, Laurence; Sabatier, Laure; Sebastià, Natividad; Slabbert, Jacobus; Sommer, Sylwester; Stuck Oliveira, Monica; Subramanian, Uma; Suto, Yumiko; Que, Tran; Testa, Antonella; Terzoudi, Georgia; Vral, Anne; Wilkins, Ruth; Yanti, LusiYanti; Zafiropoulos, Demetre; Wojcik, Andrzej

    2017-01-01

    Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.

  12. Not Normal: the uncertainties of scientific measurements

    NASA Astrophysics Data System (ADS)

    Bailey, David C.

    2017-01-01

    Judging the significance and reproducibility of quantitative research requires a good understanding of relevant uncertainties, but it is often unclear how well these have been evaluated and what they imply. Reported scientific uncertainties were studied by analysing 41 000 measurements of 3200 quantities from medicine, nuclear and particle physics, and interlaboratory comparisons ranging from chemistry to toxicology. Outliers are common, with 5σ disagreements up to five orders of magnitude more frequent than naively expected. Uncertainty-normalized differences between multiple measurements of the same quantity are consistent with heavy-tailed Student's t-distributions that are often almost Cauchy, far from a Gaussian Normal bell curve. Medical research uncertainties are generally as well evaluated as those in physics, but physics uncertainty improves more rapidly, making feasible simple significance criteria such as the 5σ discovery convention in particle physics. Contributions to measurement uncertainty from mistakes and unknown problems are not completely unpredictable. Such errors appear to have power-law distributions consistent with how designed complex systems fail, and how unknown systematic errors are constrained by researchers. This better understanding may help improve analysis and meta-analysis of data, and help scientists and the public have more realistic expectations of what scientific results imply.

  13. Level 1 environmental assessment performance evaluation. Final report jun 77-oct 78

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estes, E.D.; Smith, F.; Wagoner, D.E.

    1979-02-01

    The report gives results of a two-phased evaluation of Level 1 environmental assessment procedures. Results from Phase I, a field evaluation of the Source Assessment Sampling System (SASS), showed that the SASS train performed well within the desired factor of 3 Level 1 accuracy limit. Three sample runs were made with two SASS trains sampling simultaneously and from approximately the same sampling point in a horizontal duct. A Method-5 train was used to estimate the 'true' particulate loading. The sampling systems were upstream of the control devices to ensure collection of sufficient material for comparison of total particulate, particle sizemore » distribution, organic classes, and trace elements. Phase II consisted of providing each of three organizations with three types of control samples to challenge the spectrum of Level 1 analytical procedures: an artificial sample in methylene chloride, an artificial sample on a flyash matrix, and a real sample composed of the combined XAD-2 resin extracts from all Phase I runs. Phase II results showed that when the Level 1 analytical procedures are carefully applied, data of acceptable accuracy is obtained. Estimates of intralaboratory and interlaboratory precision are made.« less

  14. Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

    PubMed

    Trompier, François; Burbidge, Christopher; Bassinet, Céline; Baumann, Marion; Bortolin, Emanuela; De Angelis, Cinzia; Eakins, Jonathan; Della Monaca, Sara; Fattibene, Paola; Quattrini, Maria Cristina; Tanner, Rick; Wieser, Albrecht; Woda, Clemens

    2017-01-01

    In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Resonance (EPR) dosimetry techniques. OSL is applied to electronic components and EPR to touch-screen glass from mobile phones. To implement these new approaches, several blind tests and inter-laboratory comparisons (ILC) were organized for each assay. OSL systems have shown good performances. EPR systems also show good performance in controlled conditions, but ILC have also demonstrated that post-irradiation exposure to sunlight increases the complexity of the EPR signal analysis. Physically-based dosimetry techniques present high capacity, new possibilities for accident dosimetry, especially in the case of large-scale events. Some of the techniques applied can be considered as operational (e.g. OSL on Surface Mounting Devices [SMD]) and provide a large increase of measurement capacity for existing networks. Other techniques and devices currently undergoing validation or development in Europe could lead to considerable increases in the capacity of the RENEB accident dosimetry network.

  15. Quantitation of fumonisin B1 and B2 in feed using FMOC pre-column derivatization with HPLC and fluorescence detection.

    PubMed

    Smith, Lori L; Francis, Kyle A; Johnson, Joseph T; Gaskill, Cynthia L

    2017-11-01

    Pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was determined to be effective for quantitation of fumonisins B 1 and B 2 in feed. Liquid-solid extraction, clean-up using immunoaffinity solid phase extraction chromatography, and FMOC-derivatization preceded analysis by reverse phase HPLC with fluorescence. Instrument response was unchanged in the presence of matrix, indicating no need to use matrix-matched calibrants. Furthermore, high method recoveries indicated calibrants do not need to undergo clean-up to account for analyte loss. Established method features include linear instrument response from 0.04-2.5µg/mL and stable derivatized calibrants over 7days. Fortified cornmeal method recoveries from 0.1-30.0μg/g were determined for FB 1 (75.1%-109%) and FB 2 (96.0%-115.2%). Inter-assay precision ranged from 1.0%-16.7%. Method accuracy was further confirmed using certified reference material. Inter-laboratory comparison with naturally-contaminated field corn demonstrated equivalent results with conventional derivatization. These results indicate FMOC derivatization is a suitable alternative for fumonisins B 1 and B 2 quantitation in corn-based feeds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Towards a standardization of biomethane potential tests.

    PubMed

    Holliger, Christof; Alves, Madalena; Andrade, Diana; Angelidaki, Irini; Astals, Sergi; Baier, Urs; Bougrier, Claire; Buffière, Pierre; Carballa, Marta; de Wilde, Vinnie; Ebertseder, Florian; Fernández, Belén; Ficara, Elena; Fotidis, Ioannis; Frigon, Jean-Claude; de Laclos, Hélène Fruteau; Ghasimi, Dara S M; Hack, Gabrielle; Hartel, Mathias; Heerenklage, Joern; Horvath, Ilona Sarvari; Jenicek, Pavel; Koch, Konrad; Krautwald, Judith; Lizasoain, Javier; Liu, Jing; Mosberger, Lona; Nistor, Mihaela; Oechsner, Hans; Oliveira, João Vítor; Paterson, Mark; Pauss, André; Pommier, Sébastien; Porqueddu, Isabella; Raposo, Francisco; Ribeiro, Thierry; Rüsch Pfund, Florian; Strömberg, Sten; Torrijos, Michel; van Eekert, Miriam; van Lier, Jules; Wedwitschka, Harald; Wierinck, Isabella

    2016-12-01

    Production of biogas from different organic materials is a most interesting source of renewable energy. The biomethane potential (BMP) of these materials has to be determined to get insight in design parameters for anaerobic digesters. Although several norms and guidelines for BMP tests exist, inter-laboratory tests regularly show high variability of BMPs for the same substrate. A workshop was held in June 2015, in Leysin, Switzerland, with over 40 attendees from 30 laboratories around the world, to agree on common solutions to the conundrum of inconsistent BMP test results. This paper presents the consensus of the intense roundtable discussions and cross-comparison of methodologies used in respective laboratories. Compulsory elements for the validation of BMP results were defined. They include the minimal number of replicates, the request to carry out blank and positive control assays, a criterion for the test duration, details on BMP calculation, and last but not least criteria for rejection of the BMP tests. Finally, recommendations on items that strongly influence the outcome of BMP tests such as inoculum characteristics, substrate preparation, test setup, and data analysis are presented to increase the probability of obtaining validated and reproducible results.

  17. Isotope ratio measurements of pg-size plutonium samples using TIMS in combination with "multiple ion counting" and filament carburization

    NASA Astrophysics Data System (ADS)

    Jakopic, Rozle; Richter, Stephan; Kühn, Heinz; Benedik, Ljudmila; Pihlar, Boris; Aregbe, Yetunde

    2009-01-01

    A sample preparation procedure for isotopic measurements using thermal ionization mass spectrometry (TIMS) was developed which employs the technique of carburization of rhenium filaments. Carburized filaments were prepared in a special vacuum chamber in which the filaments were exposed to benzene vapour as a carbon supply and carburized electrothermally. To find the optimal conditions for the carburization and isotopic measurements using TIMS, the influence of various parameters such as benzene pressure, carburization current and the exposure time were tested. As a result, carburization of the filaments improved the overall efficiency by one order of magnitude. Additionally, a new "multi-dynamic" measurement technique was developed for Pu isotope ratio measurements using a "multiple ion counting" (MIC) system. This technique was combined with filament carburization and applied to the NBL-137 isotopic standard and samples of the NUSIMEP 5 inter-laboratory comparison campaign, which included certified plutonium materials at the ppt-level. The multi-dynamic measurement technique for plutonium, in combination with filament carburization, has been shown to significantly improve the precision and accuracy for isotopic analysis of environmental samples with low-levels of plutonium.

  18. Not Normal: the uncertainties of scientific measurements

    PubMed Central

    2017-01-01

    Judging the significance and reproducibility of quantitative research requires a good understanding of relevant uncertainties, but it is often unclear how well these have been evaluated and what they imply. Reported scientific uncertainties were studied by analysing 41 000 measurements of 3200 quantities from medicine, nuclear and particle physics, and interlaboratory comparisons ranging from chemistry to toxicology. Outliers are common, with 5σ disagreements up to five orders of magnitude more frequent than naively expected. Uncertainty-normalized differences between multiple measurements of the same quantity are consistent with heavy-tailed Student’s t-distributions that are often almost Cauchy, far from a Gaussian Normal bell curve. Medical research uncertainties are generally as well evaluated as those in physics, but physics uncertainty improves more rapidly, making feasible simple significance criteria such as the 5σ discovery convention in particle physics. Contributions to measurement uncertainty from mistakes and unknown problems are not completely unpredictable. Such errors appear to have power-law distributions consistent with how designed complex systems fail, and how unknown systematic errors are constrained by researchers. This better understanding may help improve analysis and meta-analysis of data, and help scientists and the public have more realistic expectations of what scientific results imply. PMID:28280557

  19. Application of self-organizing feature maps to analyze the relationships between ignitable liquids and selected mass spectral ions.

    PubMed

    Frisch-Daiello, Jessica L; Williams, Mary R; Waddell, Erin E; Sigman, Michael E

    2014-03-01

    The unsupervised artificial neural networks method of self-organizing feature maps (SOFMs) is applied to spectral data of ignitable liquids to visualize the grouping of similar ignitable liquids with respect to their American Society for Testing and Materials (ASTM) class designations and to determine the ions associated with each group. The spectral data consists of extracted ion spectra (EIS), defined as the time-averaged mass spectrum across the chromatographic profile for select ions, where the selected ions are a subset of ions from Table 2 of the ASTM standard E1618-11. Utilization of the EIS allows for inter-laboratory comparisons without the concern of retention time shifts. The trained SOFM demonstrates clustering of the ignitable liquid samples according to designated ASTM classes. The EIS of select samples designated as miscellaneous or oxygenated as well as ignitable liquid residues from fire debris samples are projected onto the SOFM. The results indicate the similarities and differences between the variables of the newly projected data compared to those of the data used to train the SOFM. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Results of interlaboratory comparison of fission-track age standards: Fission-track workshop-1984

    USGS Publications Warehouse

    Miller, D.S.; Duddy, I.R.; Green, P.F.; Hurford, A.J.; Naeser, C.W.

    1985-01-01

    Five samples were made available as standards for the 1984 Fission Track Workshop held in the summer of 1984 (Rensselaer Polytechnic Institute, Troy, New York). Two zircons, two apatites and a sphene were distributed prior to the meeting to 40 different laboratories. To date, 24 different analysts have reported results. The isotopic ages of the standards ranged from 16.8 to 98.7 Myr. Only the statement that the age of each sample was less than 200 Myr was provided with the set of standards distributed. Consequently, each laboratory was required to use their laboratory's accepted treatment (irradiation level, etching conditions, counting conditions, etc.) for these samples. The results show that some workers have serious problems in achieving accurate age determinations. This emphasizes the need to calibrate experimental techniques and counting procedures against age standards before unknown ages are determined. Any fission-track age determination published or submitted for publication can only be considered reliable if it is supported by evidence of consistent determinations on age standards. Only this can provide the scientific community with the background to build up confidence concerning the validity of the fission-track method. ?? 1985.

  1. Quality-assurance data for routine water quality analyses by the U. S. Geological Survey laboratory in Troy, New York; July 1993 through June 1995

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2001-01-01

    A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data

  2. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    USGS Publications Warehouse

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  3. AACCI Approved Methods Technical Committee Report: Collaborative study on a method for determining the water holding capacity of pulse flours and their protein materials (AACCI Method 56-37.01)

    USDA-ARS?s Scientific Manuscript database

    A method for determining water holding capacity (WHC) of pulse flours and protein materials has been developed and subjected to an interlaboratory study. Eleven participants analyzed twelve blind duplicates of six different samples in a collaborative study to evaluate the repeatability and reproduci...

  4. Interlaboratory discrepancy of antigenuria results in 2 patients with AIDS and histoplasmosis.

    PubMed

    McKinsey, David S; McKinsey, Joel P; Northcutt, Noelle; Sarria, Juan C

    2009-01-01

    Histoplasma polysaccharide antigen testing is used routinely to diagnose histoplasmosis. At least 3 antigen tests are commercially available. Controversy exists about the relative accuracy of these tests. We report 2 patients with AIDS and culture-confirmed Histoplasma capsulatum meningitis from whom discrepant Histoplasma polysaccharide antigen results were obtained from different laboratories and discuss the potential clinical implications of these results.

  5. Designing Successful Proteomics Experiments.

    PubMed

    Ruderman, Daniel

    2017-01-01

    Because proteomics experiments are so complex they can readily fail, and do so without clear cause. Using standard experimental design techniques and incorporating quality control can greatly increase the chances of success. This chapter introduces the relevant concepts and provides examples specific to proteomic workflows. Applying these notions to design successful proteomics experiments is straightforward. It can help identify failure causes and greatly increase the likelihood of inter-laboratory reproducibility.

  6. Within-Subject Interlaboratory Variability of QuantiFERON-TB Gold In-Tube Tests

    DTIC Science & Technology

    2012-09-06

    QuantiFERONH-TB Gold In-Tube test (QFT-GIT) is a viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection...viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection. However, within-subject variability may limit test...release assays (IGRAs) are designed to detect both latent Mycobacterium tuberculosis infection (LTBI) and infections manifesting as active

  7. Use of HOMA-IR to diagnose non-alcoholic fatty liver disease: a population-based and inter-laboratory study.

    PubMed

    Isokuortti, Elina; Zhou, You; Peltonen, Markku; Bugianesi, Elisabetta; Clement, Karine; Bonnefont-Rousselot, Dominique; Lacorte, Jean-Marc; Gastaldelli, Amalia; Schuppan, Detlef; Schattenberg, Jörn M; Hakkarainen, Antti; Lundbom, Nina; Jousilahti, Pekka; Männistö, Satu; Keinänen-Kiukaanniemi, Sirkka; Saltevo, Juha; Anstee, Quentin M; Yki-Järvinen, Hannele

    2017-10-01

    Recent European guidelines for non-alcoholic fatty liver disease (NAFLD) call for reference values for HOMA-IR. In this study, we aimed to determine: (1) the upper limit of normal HOMA-IR in two population-based cohorts; (2) the HOMA-IR corresponding to NAFLD; (3) the effect of sex and PNPLA3 genotype at rs738409 on HOMA-IR; and (4) inter-laboratory variations in HOMA-IR. We identified healthy individuals in two population-based cohorts (FINRISK 2007 [n = 5024] and the Programme for Prevention of Type 2 Diabetes in Finland [FIN-D2D; n = 2849]) to define the upper 95th percentile of HOMA-IR. Non-obese individuals with normal fasting glucose levels, no excessive alcohol use, no known diseases and no use of any drugs were considered healthy. The optimal HOMA-IR cut-off for NAFLD (liver fat ≥5.56%, based on the Dallas Heart Study) was determined in 368 non-diabetic individuals (35% with NAFLD), whose liver fat was measured using proton magnetic resonance spectroscopy ( 1 H-MRS). Samples from ten individuals were simultaneously analysed for HOMA-IR in seven European laboratories. The upper 95th percentiles of HOMA-IR were 1.9 and 2.0 in healthy individuals in the FINRISK (n = 1167) and FIN-D2D (n = 459) cohorts. Sex or PNPLA3 genotype did not influence these values. The optimal HOMA-IR cut-off for NAFLD was 1.9 (sensitivity 87%, specificity 79%). A HOMA-IR of 2.0 corresponded to normal liver fat (<5.56% on 1 H-MRS) in linear regression analysis. The 2.0 HOMA-IR measured in Helsinki corresponded to 1.3, 1.6, 1.8, 1.8, 2.0 and 2.1 in six other laboratories. The inter-laboratory CV% of HOMA-IR was 25% due to inter-assay variation in insulin (25%) rather than glucose (5%) measurements. The upper limit of HOMA-IR in population-based cohorts closely corresponds to that of normal liver fat. Standardisation of insulin assays would be the first step towards definition of normal values for HOMA-IR.

  8. 1993-94-95 Kara sea field experiments and analysis. 1995 progress report to onr Arctic Nuclear Waste Assessment Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, G.W.; August, R.A.; King, S.E.

    1996-01-14

    This progress report covers field work and laboratory analysis efforts for quantifying the environmental threat of radioactive waste released in the Arctic seas adjacent to the former Soviet Union and for studying the various transport mechanisms by which this radioactivity could effect populations of the U.S. and other countries bordering the Arctic. We obtained water, sediment, biological samples and oceanographic data from several cruises to the Kara Sea and adjacent waters and conducted detailed laboratory analyses of the samples for radionuclides and physical biological properties. In addition, we obtained water and sediment samples and conducted on site low level radionuclidemore » analysis on the Angara, Yenisey River system which drains a major part of the Siberian industrial heartland and empties into the Kara Sea. We report on radionuclide concentrations, on radionuclide transport and scrubbing by sediments, on adsorption by suspended particles, on transport by surface and benthic boundary layer currents, on the effects of benthic and demersal organisms, on studies of long term monitoring in the Arctic, and on an interlaboratory calibration for radionuclide analysis.« less

  9. Multicentric Comparative Analytical Performance Study for Molecular Detection of Low Amounts of Toxoplasma gondii from Simulated Specimens▿ †

    PubMed Central

    Sterkers, Yvon; Varlet-Marie, Emmanuelle; Cassaing, Sophie; Brenier-Pinchart, Marie-Pierre; Brun, Sophie; Dalle, Frédéric; Delhaes, Laurence; Filisetti, Denis; Pelloux, Hervé; Yera, Hélène; Bastien, Patrick

    2010-01-01

    Although screening for maternal toxoplasmic seroconversion during pregnancy is based on immunodiagnostic assays, the diagnosis of clinically relevant toxoplasmosis greatly relies upon molecular methods. A problem is that this molecular diagnosis is subject to variation of performances, mainly due to a large diversity of PCR methods and primers and the lack of standardization. The present multicentric prospective study, involving eight laboratories proficient in the molecular prenatal diagnosis of toxoplasmosis, was a first step toward the harmonization of this diagnosis among university hospitals in France. Its aim was to compare the analytical performances of different PCR protocols used for Toxoplasma detection. Each center extracted the same concentrated Toxoplasma gondii suspension and tested serial dilutions of the DNA using its own assays. Differences in analytical sensitivities were observed between assays, particularly at low parasite concentrations (≤2 T. gondii genomes per reaction tube), with “performance scores” differing by a 20-fold factor among laboratories. Our data stress the fact that differences do exist in the performances of molecular assays in spite of expertise in the matter; we propose that laboratories work toward a detection threshold defined for a best sensitivity of this diagnosis. Moreover, on the one hand, intralaboratory comparisons confirmed previous studies showing that rep529 is a more adequate DNA target for this diagnosis than the widely used B1 gene. But, on the other hand, interlaboratory comparisons showed differences that appear independent of the target, primers, or technology and that hence rely essentially on proficiency and care in the optimization of PCR conditions. PMID:20610670

  10. An inter-laboratory comparison of PNH clone detection by high-sensitivity flow cytometry in a Russian cohort.

    PubMed

    Sipol, Alexandra A; Babenko, Elena V; Borisov, Vyacheslav I; Naumova, Elena V; Boyakova, Elena V; Yakunin, Dimitry I; Glazanova, Tatyana V; Chubukina, Zhanna V; Pronkina, Natalya V; Popov, Alexander M; Saveliev, Leonid I; Lugovskaya, Svetlana A; Lisukov, Igor A; Kulagin, Alexander D; Illingworth, Andrea J

    2015-01-01

    Paroxysmal nocturnal hemoglobinuria (PNH) is an acquired clonal stem cell disorder characterized by partial or absolute deficiency of glycophosphatidyl-inositol (GPI) anchor-linked surface proteins on blood cells. A lack of precise diagnostic standards for flow cytometry has hampered useful comparisons of data between laboratories. We report data from the first study evaluating the reproducibility of high-sensitivity flow cytometry for PNH in Russia. PNH clone sizes were determined at diagnosis in PNH patients at a central laboratory and compared with follow-up measurements in six laboratories across the country. Analyses in each laboratory were performed according to recommendations from the International Clinical Cytometry Society (ICCS) and the more recent 'practical guidelines'. Follow-up measurements were compared with each other and with the values determined at diagnosis. PNH clone size measurements were determined in seven diagnosed PNH patients (five females, two males: mean age 37 years); five had a history of aplastic anemia and three (one with and two without aplastic anemia) had severe hemolytic PNH and elevated plasma lactate dehydrogenase. PNH clone sizes at diagnosis were low in patients with less severe clinical symptoms (0.41-9.7% of granulocytes) and high in patients with severe symptoms (58-99%). There were only minimal differences in the follow-up clone size measurement for each patient between the six laboratories, particularly in those with high values at diagnosis. The ICCS-recommended high-sensitivity flow cytometry protocol was effective for detecting major and minor PNH clones in Russian PNH patients, and showed high reproducibility between laboratories.

  11. Comparison of solvent/derivatization agent systems for determination of extractable toluene diisocyanate from flexible polyurethane foam.

    PubMed

    Vangronsveld, Erik; Berckmans, Steven; Spence, Mark

    2013-06-01

    Flexible polyurethane foam (FPF) is produced from the reaction of toluene diisocyanate (TDI) and polyols. Limited and conflicting results exist in the literature concerning the presence of unreacted TDI remaining in FPF as determined by various solvent extraction and analysis techniques. This study reports investigations into the effect of several solvent/derivatization agent combinations on extractable TDI results and suggests a preferred method. The suggested preferred method employs a syringe-based multiple extraction of foam samples with a toluene solution of 1-(2-methoxyphenyl)-piperazine. Extracts are analyzed by liquid chromatography using an ion trap mass spectrometry detection technique. Detection limits of the method are ~10ng TDI g(-1) foam (10 ppb, w/w) for each TDI isomer (i.e. 2,4-TDI and 2,6-TDI). The method was evaluated by a three-laboratory interlaboratory comparison using two representative foam samples. The total extractable TDI results found by the three labs for the two foams were in good agreement (relative standard deviation of the mean of 30-40%). The method has utility as a basis for comparing FPFs, but the interpretation of extractable TDI results using any solvent as the true value for 'free' or 'unreacted' TDI in the foam is problematic, as demonstrated by the difference in the extracted TDI results from the different extraction systems studied. Further, a consideration of polyurethane foam chemistry raises the possibility that extractable TDI may result from decomposition of parts of the foam structure (e.g. dimers, biurets, and allophanates) by the extraction system.

  12. Electrophoretic mobilities of cultured human embryonic kidney cells in various buffers

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Data on the electrophoretic mobility distributions of cells in the new D-1 buffer and the interlaboratory standardization of urokinase assay methods are presented. A table of cell strains and recent data on cell dispersal methods are also included. It was decided that glycerol in A-1 electrophoretic mobility data on cultured human embryonic kidney cells subjected to electrophoresis in this buffer. The buffer composition is presented.

  13. Interlaboratory study of DNA extraction from multiple ground samples, multiplex real-time PCR, and multiplex qualitative PCR for individual kernel detection system of genetically modified maize.

    PubMed

    Akiyama, Hiroshi; Sakata, Kozue; Makiyma, Daiki; Nakamura, Kosuke; Teshima, Reiko; Nakashima, Akie; Ogawa, Asako; Yamagishi, Toru; Futo, Satoshi; Oguchi, Taichi; Mano, Junichi; Kitta, Kazumi

    2011-01-01

    In many countries, the labeling of grains, feed, and foodstuff is mandatory if the genetically modified (GM) organism content exceeds a certain level of approved GM varieties. We previously developed an individual kernel detection system consisting of grinding individual kernels, DNA extraction from the individually ground kernels, GM detection using multiplex real-time PCR, and GM event detection using multiplex qualitative PCR to analyze the precise commingling level and varieties of GM maize in real sample grains. We performed the interlaboratory study of the DNA extraction with multiple ground samples, multiplex real-time PCR detection, and multiplex qualitative PCR detection to evaluate its applicability, practicality, and ruggedness for the individual kernel detection system of GM maize. DNA extraction with multiple ground samples, multiplex real-time PCR, and multiplex qualitative PCR were evaluated by five laboratories in Japan, and all results from these laboratories were consistent with the expected results in terms of the commingling level and event analysis. Thus, the DNA extraction with multiple ground samples, multiplex real-time PCR, and multiplex qualitative PCR for the individual kernel detection system is applicable and practicable in a laboratory to regulate the commingling level of GM maize grain for GM samples, including stacked GM maize.

  14. A Reference Method for Measuring Emissions of SVOCs in ...

    EPA Pesticide Factsheets

    Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenges associated with SVOC analysis and the lack of validation procedures. Thus there is an urgent need for a reliable and accurate chamber test method to verify the performance of these measurements. A reference method employing a specially-designed chamber and experimental protocol has been developed and is undergoing extensive evaluation. A pilot interlaboratory study (ILS) has been conducted with five laboratories performing chamber tests under identical conditions. Results showed inter-laboratory variations at 25% for SVOC emission rates, with greater agreement observed between intra-laboratory measurements for most of the participating laboratories. The measured concentration profiles also compared reasonably well to the mechanistic model, demonstrating the feasibility of the proposed reference method to independently assess laboratory performance and validate SVOC emission tests. There is an urgent need for improved understanding of the measurement uncertainties associated with SVOC emissions testing. The creation of specially-designed chambers and well-characterized materials serves as a critical prerequisite for improving the procedure used to measure SVOCs emitted from indoor

  15. Inter-laboratory study to characterize the detection of serum antibodies against porcine epidemic diarrhoea virus.

    PubMed

    Strandbygaard, Bertel; Lavazza, Antonio; Lelli, Davide; Blanchard, Yannick; Grasland, Béatrice; Poder, Sophie Le; Rose, Nicolas; Steinbach, Falko; van der Poel, Wim H M; Widén, Frederik; Belsham, Graham J; Bøtner, Anette

    2016-12-25

    Porcine epidemic diarrhea virus (PEDV) has caused extensive economic losses to pig producers in many countries. It was recently introduced, for the first time, into North America and outbreaks have occurred again in multiple countries within Europe as well. To assess the properties of various diagnostic assays for the detection of PEDV infection, multiple panels of porcine sera have been shared and tested for the presence of antibodies against PEDV in an inter-laboratory ring trial. Different laboratories have used a variety of "in house" ELISAs and also one commercial assay. The sensitivity and specificity of each assay has been estimated using a Bayesian analysis applied to the ring trial results obtained with the different assays in the absence of a gold standard. Although different characteristics were found, it can be concluded that each of the assays used can detect infection of pigs at a herd level by either the early European strains of PEDV or the recently circulating strains (INDEL and non-INDEL). However, not all the assays seem suitable for demonstrating freedom from disease in a country. The results from individual animals, especially when the infection has occurred within an experimental situation, show more variation. Copyright © 2016. Published by Elsevier B.V.

  16. Commutability of NIST SRM 1955 Homocysteine and Folate in Frozen Human Serum with selected total homocysteine immunoassays and enzymatic assays.

    PubMed

    Nelson, Bryant C; Pfeiffer, Christine M; Zhang, Ming; Duewer, David L; Sharpless, Katherine E; Lippa, Katrice A

    2008-09-01

    The National Institute of Standards and Technology (NIST) has recently developed Standard Reference Material (SRM) 1955 Homocysteine and Folate in Frozen Human Serum with certified values for total homocysteine (tHcy) and 5-methyl-tetrahydrofolic acid. NIST has performed an international, interlaboratory assessment of SRM 1955 commutability; results are reported for tHcy only. Total Hcy was measured in 20 patient sera and in 3 levels of SRM 1955 using 14 immunoassays and/or enzymatic assays. Liquid chromatography/tandem mass spectrometry was utilized as the reference assay. An "errors-in-variables" statistical model was utilized to assess the commutability of SRM 1955. Normalized residuals ranged from -2.65 to 2.19 for SRM 1955. The median interlaboratory/interassay imprecision (CV) was approximately 4% for patient specimens and ranged from approximately 3% to approximately 7% for SRM 1955. The median intra-assay imprecision ranged from approximately 1% to approximately 13%. Orthogonal residuals, as a descriptor of assay accuracy, ranged from 0.29 to 7.71 and from 0.20 to 2.22 for patient specimens and SRM 1955 samples, respectively. The current study suggests that SRM 1955 is commutable with the investigated tHcy assays; however, a broader specimen set needs to be evaluated to completely substantiate this conclusion.

  17. Inter-laboratory verification of European pharmacopoeia monograph on derivative spectrophotometry method and its application for chitosan hydrochloride.

    PubMed

    Marković, Bojan; Ignjatović, Janko; Vujadinović, Mirjana; Savić, Vedrana; Vladimirov, Sote; Karljiković-Rajić, Katarina

    2015-01-01

    Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Applicability of the DPPH assay for evaluating the antioxidant capacity of food additives - inter-laboratory evaluation study -.

    PubMed

    Shimamura, Tomoko; Sumikura, Yoshihiro; Yamazaki, Takeshi; Tada, Atsuko; Kashiwagi, Takehiro; Ishikawa, Hiroya; Matsui, Toshiro; Sugimoto, Naoki; Akiyama, Hiroshi; Ukeda, Hiroyuki

    2014-01-01

    An inter-laboratory evaluation study was conducted in order to evaluate the antioxidant capacity of food additives by using a 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. Four antioxidants used as existing food additives (i.e., tea extract, grape seed extract, enju extract, and d-α-tocopherol) and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) were used as analytical samples, and 14 laboratories participated in this study. The repeatability relative standard deviation (RSD(r)) of the IC50 of Trolox, four antioxidants, and the Trolox equivalent antioxidant capacity (TEAC) were 1.8-2.2%, 2.2-2.9%, and 2.1-2.5%, respectively. Thus, the proposed DPPH assay showed good performance within the same laboratory. The reproducibility relative standard deviation (RSD(R)) of IC50 of Trolox, four antioxidants, and TEAC were 4.0-7.9%, 6.0-11%, and 3.7-9.3%, respectively. The RSD(R)/RSD(r) values of TEAC were lower than, or nearly equal to, those of IC50 of the four antioxidants, suggesting that the use of TEAC was effective for reducing the variance among the laboratories. These results showed that the proposed DPPH assay could be used as a standard method to evaluate the antioxidant capacity of food additives.

  19. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Toward a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Hacke, Peter L.; Kempe, Michael D.

    2015-06-14

    Reduced optical transmittance of encapsulation resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of installations in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding thatmore » will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xe, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests. Index Terms -- reliability, durability, thermal activation.« less

  20. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    2015-08-12

    Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding thatmore » will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.« less

  1. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    2015-06-14

    Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding thatmore » will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.« less

  2. Construction of measurement uncertainty profiles for quantitative analysis of genetically modified organisms based on interlaboratory validation data.

    PubMed

    Macarthur, Roy; Feinberg, Max; Bertheau, Yves

    2010-01-01

    A method is presented for estimating the size of uncertainty associated with the measurement of products derived from genetically modified organisms (GMOs). The method is based on the uncertainty profile, which is an extension, for the estimation of uncertainty, of a recent graphical statistical tool called an accuracy profile that was developed for the validation of quantitative analytical methods. The application of uncertainty profiles as an aid to decision making and assessment of fitness for purpose is also presented. Results of the measurement of the quantity of GMOs in flour by PCR-based methods collected through a number of interlaboratory studies followed the log-normal distribution. Uncertainty profiles built using the results generally give an expected range for measurement results of 50-200% of reference concentrations for materials that contain at least 1% GMO. This range is consistent with European Network of GM Laboratories and the European Union (EU) Community Reference Laboratory validation criteria and can be used as a fitness for purpose criterion for measurement methods. The effect on the enforcement of EU labeling regulations is that, in general, an individual analytical result needs to be < 0.45% to demonstrate compliance, and > 1.8% to demonstrate noncompliance with a labeling threshold of 0.9%.

  3. ENZYME-LINKED IMMUNOSORBENT ASSAY FOR SCREENING DIOXIN SOIL CONTAMINATION BY UNCONTROLLED COMBUSTION DURING INFORMAL RECYCLING IN SLUMS

    PubMed Central

    Trindade, Mirta; Nording, Malin; Nichkova, Mikaela; Spinnel, Erik; Haglund, Peter; Last, Michael S.; Gee, Shirley; Hammock, Bruce; Last, Jerold A.; González-Sapienza, Gualberto; Brena, Beatriz M.

    2010-01-01

    Uncontrolled combustion due to garbage recycling is a widespread activity among slum dwellers in distressed economy countries and has been indicated as a major source of dioxin contamination. However, because of the high cost and complexity of gas chromatography/high-resolution mass spectrometry (GC-HRMS) analysis, the magnitude of the problem remains largely unknown. The present study describes a first approach toward the use of a dioxin antibody-based enzyme-linked immunosorbent assay (ELISA) as the basis for a sustainable, simple, and low-cost monitoring program to assess the toxicological impact of uncontrolled combustion in slums. A panel of 16 samples was analyzed by GC-HRMS and ELISA on split extracts. Close to 20% of the analyzed samples showed dioxin concentrations up to almost twice the guidance level for residential soil in several countries, pointing out the need for performing a large-scale monitoring program. Despite the potential for variations in dioxin congener distribution due to the mixed nature of the incinerated material, there was a good correlation between the toxic equivalents as determined by GC-HRMS and ELISA. Furthermore, an interlaboratory ELISA validation showed that the capacity to perform the dioxin ELISA was successfully transferred between laboratories. It was concluded that the ELISA method performed very well as a screening tool to prioritize samples for instrumental analysis, which allows cutting down costs significantly. PMID:18522475

  4. Differences in results of analyses of concurrent and split stream-water samples collected and analyzed by the US Geological Survey and the Illinois Environmental Protection Agency, 1985-91

    USGS Publications Warehouse

    Melching, C.S.; Coupe, R.H.

    1995-01-01

    During water years 1985-91, the U.S. Geological Survey (USGS) and the Illinois Environmental Protection Agency (IEPA) cooperated in the collection and analysis of concurrent and split stream-water samples from selected sites in Illinois. Concurrent samples were collected independently by field personnel from each agency at the same time and sent to the IEPA laboratory, whereas the split samples were collected by USGS field personnel and divided into aliquots that were sent to each agency's laboratory for analysis. The water-quality data from these programs were examined by means of the Wilcoxon signed ranks test to identify statistically significant differences between results of the USGS and IEPA analyses. The data sets for constituents and properties identified by the Wilcoxon test as having significant differences were further examined by use of the paired t-test, mean relative percentage difference, and scattergrams to determine if the differences were important. Of the 63 constituents and properties in the concurrent-sample analysis, differences in only 2 (pH and ammonia) were statistically significant and large enough to concern water-quality engineers and planners. Of the 27 constituents and properties in the split-sample analysis, differences in 9 (turbidity, dissolved potassium, ammonia, total phosphorus, dissolved aluminum, dissolved barium, dissolved iron, dissolved manganese, and dissolved nickel) were statistically significant and large enough to con- cern water-quality engineers and planners. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between paris of split samples were compared to the precision of the laboratory method used and the interlaboratory precision of measuring a given concentration or property. Consideration of method precision indicated that differences between concurrent samples were insignificant for all concentrations and properties except pH, and that differences between split samples were significant for all concentrations and properties. Consideration of interlaboratory precision indicated that the differences between the split samples were not unusually large. The results for the split samples illustrate the difficulty in obtaining comparable and accurate water-quality data.

  5. Microarray labeling extension values: laboratory signatures for Affymetrix GeneChips

    PubMed Central

    Lee, Yun-Shien; Chen, Chun-Houh; Tsai, Chi-Neu; Tsai, Chia-Lung; Chao, Angel; Wang, Tzu-Hao

    2009-01-01

    Interlaboratory comparison of microarray data, even when using the same platform, imposes several challenges to scientists. RNA quality, RNA labeling efficiency, hybridization procedures and data-mining tools can all contribute variations in each laboratory. In Affymetrix GeneChips, about 11–20 different 25-mer oligonucleotides are used to measure the level of each transcript. Here, we report that ‘labeling extension values (LEVs)’, which are correlation coefficients between probe intensities and probe positions, are highly correlated with the gene expression levels (GEVs) on eukayotic Affymetrix microarray data. By analyzing LEVs and GEVs in the publicly available 2414 cel files of 20 Affymetrix microarray types covering 13 species, we found that correlations between LEVs and GEVs only exist in eukaryotic RNAs, but not in prokaryotic ones. Surprisingly, Affymetrix results of the same specimens that were analyzed in different laboratories could be clearly differentiated only by LEVs, leading to the identification of ‘laboratory signatures’. In the examined dataset, GSE10797, filtering out high-LEV genes did not compromise the discovery of biological processes that are constructed by differentially expressed genes. In conclusion, LEVs provide a new filtering parameter for microarray analysis of gene expression and it may improve the inter- and intralaboratory comparability of Affymetrix GeneChips data. PMID:19295132

  6. LC-MSMS assays of urinary cortisol, a comparison between four in-house assays.

    PubMed

    Brossaud, Julie; Leban, Monique; Corcuff, Jean-Benoit; Boux de Casson, Florence; Leloupp, Anne-Gaëlle; Masson, Damien; Moal, Valérie; Bach-Ngohou, Kalyane

    2018-06-27

    Twenty-four hour urinary free cortisol (UFC) determination can be used for screening and follow-up of Cushing syndrome (CS). As immunoassay methods lack specificity for UFC measurement, the use of high-performance liquid chromatography coupled to mass spectrometer (LC-MSMS) is recommended. The aim of our study was to compare UFC results using four LC-MSMS methods performed in four independent laboratories in order to evaluate interlaboratory agreement. Frozen aliquots of 24-h urine samples (78 healthy volunteers and 20 patients with CS) were sent to four different laboratories for analysis. Following liquid-liquid or solid-liquid extraction, UFC were determined using four different LC-MSMS assay. UFC intra- and interassays variation coefficients were lower than 10% for each centre. External quality control results were not significantly different. UFC normal ranges (established from healthy volunteers) were 17-126, 15-134, 12-118 and 27-157 nmol/day, respectively. Classification of UFC from healthy volunteers and patients with CS using a 95th percentile threshold was similar. However, for extreme UFC values (<50 or >270 nmol/day), negative or positive bias was noted. Even for highly specific methods such as LC-MSMS, variations of results can be found depending on analytical process. Validation of LC-MSMS methods including determination of the reference range is essential.

  7. Determination of perfluorinated alkyl acid concentrations in biological standard reference materials.

    PubMed

    Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M

    2012-11-01

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.

  8. Inter-laboratory comparison of elemental analysis and gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS). Part I: delta13C measurements of selected compounds for the development of an isotopic Grob-test.

    PubMed

    Serra, F; Janeiro, A; Calderone, G; Rojas, J M Moreno; Rhodes, C; Gonthier, L A; Martin, F; Lees, M; Mosandl, A; Sewenig, S; Hener, U; Henriques, B; Ramalho, L; Reniero, F; Teixeira, A J; Guillou, C

    2007-03-01

    This study was directed towards investigating suitable compounds to be used as stable isotope reference materials for gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) calibration. Several compounds were selected from those used in the 'Grob-test' mixture. Oxygen- and nitrogen-containing substances were added to these compounds to allow the mixture to be used as a possible multi-isotopic calibration tool for 2H/1H, 13C/12C, 15N/14N and 18O/16O ratio determinations. In this paper we present the results of delta13C measurements performed by the consortium of the five laboratories taking part in this inter-calibration exercise. All the compounds were individually assessed for homogeneity, short-term stability and long-term stability by means of EA-IRMS, as required by the bureau communitaire de reference (BCR) Guide for Production of Certified Reference Materials. The results were compared then with the GC-C-IRMS measurements using both polar and non-polar columns, and the final mixture of selected compounds underwent a further certification exercise assessing limits of accuracy and reproducibility under specified GC-C-IRMS conditions. Copyright 2007 John Wiley & Sons, Ltd.

  9. Evaluation of uncertainty in the adjustment of fundamental constants

    NASA Astrophysics Data System (ADS)

    Bodnar, Olha; Elster, Clemens; Fischer, Joachim; Possolo, Antonio; Toman, Blaza

    2016-02-01

    Combining multiple measurement results for the same quantity is an important task in metrology and in many other areas. Examples include the determination of fundamental constants, the calculation of reference values in interlaboratory comparisons, or the meta-analysis of clinical studies. However, neither the GUM nor its supplements give any guidance for this task. Various approaches are applied such as weighted least-squares in conjunction with the Birge ratio or random effects models. While the former approach, which is based on a location-scale model, is particularly popular in metrology, the latter represents a standard tool used in statistics for meta-analysis. We investigate the reliability and robustness of the location-scale model and the random effects model with particular focus on resulting coverage or credible intervals. The interval estimates are obtained by adopting a Bayesian point of view in conjunction with a non-informative prior that is determined by a currently favored principle for selecting non-informative priors. Both approaches are compared by applying them to simulated data as well as to data for the Planck constant and the Newtonian constant of gravitation. Our results suggest that the proposed Bayesian inference based on the random effects model is more reliable and less sensitive to model misspecifications than the approach based on the location-scale model.

  10. Assessment of relative accuracy in the determination of organic matter concentrations in aquatic systems

    USGS Publications Warehouse

    Aiken, G.; Kaplan, L.A.; Weishaar, J.

    2002-01-01

    Accurate determinations of total (TOC), dissolved (DOC) and particulate (POC) organic carbon concentrations are critical for understanding the geochemical, environmental, and ecological roles of aquatic organic matter. Of particular significance for the drinking water industry, TOC measurements are the basis for compliance with US EPA regulations. The results of an interlaboratory comparison designed to identify problems associated with the determination of organic matter concentrations in drinking water supplies are presented. The study involved 31 laboratories and a variety of commercially available analytical instruments. All participating laboratories performed well on samples of potassium hydrogen phthalate (KHP), a compound commonly used as a standard in carbon analysis. However, problems associated with the oxidation of difficult to oxidize compounds, such as dodecylbenzene sulfonic acid and caffeine, were noted. Humic substances posed fewer problems for analysts. Particulate organic matter (POM) in the form of polystyrene beads, freeze-dried bacteria and pulverized leaf material were the most difficult for all analysts, with a wide range of performances reported. The POM results indicate that the methods surveyed in this study are inappropriate for the accurate determination of POC and TOC concentration. Finally, several analysts had difficulty in efficiently separating inorganic carbon from KHP solutions, thereby biasing DOC results.

  11. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    PubMed

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  12. On the use of IRMS in forensic science: proposals for a methodological approach.

    PubMed

    Gentile, Natacha; Besson, Luc; Pazos, Diego; Delémont, Olivier; Esseiva, Pierre

    2011-10-10

    The flourishing number of publications on the use of isotope ratio mass spectrometry (IRMS) in forensic science denotes the enthusiasm and the attraction generated by this technology. IRMS has demonstrated its potential to distinguish chemically identical compounds coming from different sources. Despite the numerous applications of IRMS to a wide range of forensic materials, its implementation in a forensic framework is less straightforward than it appears. In addition, each laboratory has developed its own strategy of analysis on calibration, sequence design, standards utilisation and data treatment without a clear consensus. Through the experience acquired from research undertaken in different forensic fields, we propose a methodological framework of the whole process using IRMS methods. We emphasize the importance of considering isotopic results as part of a whole approach, when applying this technology to a particular forensic issue. The process is divided into six different steps, which should be considered for a thoughtful and relevant application. The dissection of this process into fundamental steps, further detailed, enables a better understanding of the essential, though not exhaustive, factors that have to be considered in order to obtain results of quality and sufficiently robust to proceed to retrospective analyses or interlaboratory comparisons. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. A review of isotopic composition as an indicator of the natural and anthropogenic behavior of mercury

    USGS Publications Warehouse

    Ridley, W.I.; Stetson, S.J.

    2006-01-01

    There are seven stable isotopes of Hg that can be fractionated as a result of inorganic and organic interactions. Important inorganic reactions involve speciation changes resulting from variations in environmental redox conditions, and phase changes resulting from variations in temperature and/or atmospheric pressure. Important organic reactions include methylation and demethylation, reactions that are bacterially mediated, and complexing with organic anions in soils. The measurement of Hg isotopes by multi-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS) is now sufficiently precise and sensitive that it is potentially possible to develop the systematics of Hg isotopic fractionation. This provides an opportunity to evaluate the utility of Hg isotopes in identifying source processes, transport mechanisms, and sinks. New values are provided for, 201Hg/198Hg, 200Hg/198Hg, 199Hg/198Hg for three standard materials (IRMM-AE639, SRM 1641c, SRM 3133) that can be used to make inter-laboratory data comparisons, and these values are tabulated with published isotopic information. Overall, the isotopic data for these standards agree to approximately 0.2???. The paper reviews Hg isotope studies that deal with hydrothermal ore deposits, sediments, coal and organic complexing. ?? 2006 Elsevier Ltd. All rights reserved.

  14. Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates: Phase I Results

    NASA Technical Reports Server (NTRS)

    Wells, D. N.; Allen, P. A.

    2012-01-01

    An analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted with 15 participants. Experimental results from a surface crack tension test in 2219-T8 aluminum plate provided the basis for the inter-laboratory study (ILS). The study proceeded in a blind fashion given that the analysis methodology was not specified to the participants, and key experimental results were withheld. This approach allowed the ILS to serve as a current measure of the state of the art for elastic-plastic fracture mechanics analysis. The analytical results and the associated methodologies were collected for comparison, and sources of variability were studied and isolated. The results of the study revealed that the J-integral analysis methodology using the domain integral method is robust, providing reliable J-integral values without being overly sensitive to modeling details. General modeling choices such as analysis code, model size (mesh density), crack tip meshing, or boundary conditions, were not found to be sources of significant variability. For analyses controlled only by far-field boundary conditions, the greatest source of variability in the J-integral assessment is introduced through the constitutive model. This variability can be substantially reduced by using crack mouth opening displacements to anchor the assessment. Conclusions provide recommendations for analysis standardization.

  15. Retention of aroma compounds: an interlaboratory study on the effect of the composition of food matrices on thermodynamic parameters in comparison with water.

    PubMed

    Kopjar, Mirela; Andriot, Isabelle; Saint-Eve, Anne; Souchon, Isabelle; Guichard, Elisabeth

    2010-06-01

    Partition coefficients give an indication of the retention of aroma compounds by the food matrix. Data in the literature are obtained by various methods, under various conditions and expressed in various units, and it is thus difficult to compare the results. The aim of the present study was first to obtain gas/water and gas/matrix partition coefficients of selected aroma compounds, at different temperatures, in order to calculate thermodynamic parameters and second to compare the retention of these aroma compounds in different food matrices. Yogurts containing lipids and proteins induced a higher retention of aroma compounds than model gel matrices. The observed effects strongly depend on hydrophobicity of aroma compounds showing a retention for ethyl hexanoate and a salting out effect for ethyl acetate. A small but noticeable decrease in enthalpy of affinity is observed for ethyl butyrate and ethyl hexanoate between water and food matrices, suggesting that the energy needed for the volatilization is lower in matrices than in water. The composition and complexity of a food matrix influence gas/matrix partition coefficients or aroma compounds in function of their hydrophobicity and to a lower extent enthalpy of vaporization. Copyright (c) 2010 Society of Chemical Industry.

  16. Interlaboratory comparison of autoradiographic DNA profiling measurements: precision and concordance.

    PubMed

    Duewer, D L; Lalonde, S A; Aubin, R A; Fourney, R M; Reeder, D J

    1998-05-01

    Knowledge of the expected uncertainty in restriction fragment length polymorphism (RFLP) measurements is required for confident exchange of such data among different laboratories. The total measurement uncertainty among all Technical Working Group for DNA Analysis Methods laboratories has previously been characterized and found to be acceptably small. Casework cell line control measurements provided by six Royal Canadian Mounted Police (RCMP) and 30 U.S. commercial, local, state, and Federal forensic laboratories enable quantitative determination of the within-laboratory precision and among-laboratory concordance components of measurement uncertainty typical of both sets of laboratories. Measurement precision is the same in the two countries for DNA fragments of size 1000 base pairs (bp) to 10,000 bp. However, the measurement concordance among the RCMP laboratories is clearly superior to that within the U.S. forensic community. This result is attributable to the use of a single analytical protocol in all RCMP laboratories. Concordance among U.S. laboratories cannot be improved through simple mathematical adjustments. Community-wide efforts focused on improved concordance may be the most efficient mechanism for further reduction of among-laboratory RFLP measurement uncertainty, should the resources required to fully evaluate potential cross-jurisdictional matches become burdensome as the number of RFLP profiles on record increases.

  17. [Analysis of the results of the SEIMC External Quality Control Program for HIV-1 and HCV viral loads. Year 2008].

    PubMed

    Mira, Nieves Orta; Serrano, María del Remedio Guna; Martínez, José Carlos Latorre; Ovies, María Rosario; Pérez, José L; Cardona, Concepción Gimeno

    2010-01-01

    Human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2008 SEIMC External Quality Control Program for HIV-1 and HCV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from 3 different viremic patients, in the range of 2-5 log(10) copies/mL; two of these standards were identical aiming to determine repeatability. The specificity was complete for all commercial methods, and no false positive results were reported by the participants. A significant proportion of the laboratories (24% on average) obtained values out of the accepted range (mean +/- 0.2 log(10) copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the limits (D < 0.5 log(10) copias/mL). The HCV program consisted of two standards with different viral load contents. Most of the participants (88,7%) obtained results within the accepted range (mean +/- 1.96 SD log(10) UI/mL). Post-analytical errors due to mistranscription of the results were detected for HCV, but not for the HIV-1 program. Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. 2010 Elsevier España S.L. All rights reserved.

  18. Improved Quantification of Plasma Catecholamines by the Radioenzymic Kit Method.

    DTIC Science & Technology

    1982-11-01

    Diagnostics under the tradename CAT -A-KIT. In the Up- john procedure (2) each "unknown" and control specimen is analyzed with and without addition of an...the purpose of this report includes the follow- ing: (a) to recount difficulties we initially encountered in the prescribed use of CAT -A-KITs for...with each CAT -A-KIT, (c) to describe our departure from the prescribed procedure, (d) to validate that departure through intermethod/ interlaboratory

  19. PSU/WES Interlaboratory Comparative Methodology Study of an Experimental Cementitious Repository Seal Material. Report 2. Final Results.

    DTIC Science & Technology

    1982-03-01

    meter 25 11.0 Microstructure by SEM 11.1 Introduction In order to correlate observed physical and mechanical properties in cured grout samples, a...studied at the two laboratories has proper physical properties , phase composi- tions, and microstructures for the materials used and ages covered...Scanning Electron Microscope Resolution Test Specimen ( Al -W) D. B. Ballard Research Material 100 SEM Resolution Test Specimen (AI-W)., is an alloy of

  20. A Review of Positive Ion Sensitivities for the SIMS Analysis of CMT

    DTIC Science & Technology

    1991-05-01

    microprobe. Inter-laboratory exercises organised by NRL using standardised glasses and steels’ s showed considerable agreement usually within a factor...would be sufficient oxygen to convert all the remaining matrix atoms to oxides, TeO2 and CdO. Any general theory of the lonisation of sputtered particles...Eggert equation which works well for many other matrices, such as metals, glasses and ceramics. Despite decades of basic studies there is still no

Top