Monitoring system and methods for a distributed and recoverable digital control system
NASA Technical Reports Server (NTRS)
Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)
2010-01-01
A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.
Quantitative PCR (QPCR) methods for beach monitoring by estimating abundance of Enterococcus spp. in recreational waters use internal, positive controls which address only the amplification of target DNA. In this study two internal, positive controls were developed to control for...
NASA Astrophysics Data System (ADS)
Chen, Wen; Tang, Ming
2017-04-01
The abnormal temperature rise is the precursor of the defective composite insulator in power transmission line. However no consolidated techniques or methodologies can on line monitor its internal temperature now. Thus a new method using embedding fiber Bragg grating (FBG) in fiber reinforced polymer (FRP) rod is adopted to monitor its internal temperature. To correctly demodulate the internal temperature of FRP rod from the Bragg wavelength shift of FBG, the conversion coefficient between them is deduced theoretically based on comprehensive investigation on the thermal stresses of the metal-composite joint, as well as its material and structural properties. Theoretical model shows that the conversion coefficients of FBG embedded in different positions will be different because of non-uniform thermal stress distribution, which is verified by an experiment. This work lays the theoretical foundation of monitoring the internal temperature of composite insulator with embedding FBG, which is of great importance to its health structural monitoring, especially early diagnosis.
Diesel emission reduction using internal exhaust gas recirculation
He, Xin [Denver, CO; Durrett, Russell P [Bloomfield Hills, MI
2012-01-24
A method for controlling combustion in a direct-injection diesel engine includes monitoring a crankshaft rotational position of a cylinder of the engine, monitoring an engine load, determining an intake stroke within the cylinder based upon the crankshaft rotational position, and when the engine load is less than a threshold engine load, opening an exhaust valve for the cylinder during a portion of the intake stroke.
Han, Yoonsun; Grogan-Kaylor, Andrew; Bares, Cristina; Ma, Julie; Castillo, Marcela; Delva, Jorge
2012-01-01
This study investigated the role of discrepancies between parent and youth reports of perceived parental monitoring in adolescent problem behaviors with a Chilean sample (N= 850). Higher levels of discordance concerning parental monitoring predicted greater levels of maladaptive youth behaviors. A positive association between parent-youth discordance and externalizing problems indicated that large adult-youth disagreement in parental monitoring may impose a great risk, despite protective efforts of parental monitoring. Although the direct relationship between parental monitoring and youth internalizing behaviors was not significant, parent-youth incongruence in monitoring was associated with greater levels of internalizing behaviors. Therefore, differing assessments of parental behaviors, as an indicator of less optimal family functioning, may provide important information about youth maladjustment and may potentially provide a beginning point for family-focused intervention. PMID:23097593
[Source monitoring: general presentation and review of literature in schizophrenia].
Ferchiou, A; Schürhoff, F; Bulzacka, E; Mahbouli, M; Leboyer, M; Szöke, A
2010-09-01
SOURCE MONITORING FRAMEWORK: Source monitoring refers to the ability to remember the origin of information. Three source monitoring processes can be distinguished: external source monitoring, internal or self-monitoring and reality monitoring (i.e. discrimination between internal and external sources of information). Source monitoring decisions are based on memory characteristics recorded such as perceptions, contextual information or emotional reactions and heuristic or more controlled judgement processes. Several studies suggested that specific structures in the prefrontal and the mediotemporal lobes are the main areas implicated in source monitoring. A typical source monitoring paradigm includes an items generation stage and a second stage of recognition of items (old versus new) and identification of their sources: external (usually the examiner) or internal (the subject). Several indices can be calculated based on the raw data such as the number of false alarms, attribution biases or discrimination indexes. To date, there is no standardized source monitoring task and differences in the type of items used (words, pictures), in the cognitive or emotional effort involved or in the delay between the two test stages, contribute to the heterogeneity of results. Factors such as age (either very young or very old) and emotions influence source monitoring performances. Influence of gender was not properly explored, whereas the role of IQ and selective attention is still debated. Source monitoring deficits are observed mainly in disorders affecting frontotemporal areas, such as frontal trauma, Alzheimer's disease or frontotemporal dementia. Source monitoring errors (e.g. external misattribution of self-generated information) are observed in schizophrenia and seem to correlate with positive symptomatology, in particular auditory hallucinations, thought intrusion and alien control symptoms. These results are of particular interest in clinical research because source monitoring is one of the rare cognitive tests showing a correlation with the positive dimension. Source monitoring deficits have been proposed as a potential explanation for the positive symptoms and some, but not all studies lent support to this hypothesis. Heterogeneity of studied samples, in particular different criteria to define hallucinating subjects (e.g. currently versus anytime during their lives), could explain the discordant results. Source monitoring impairments were observed in pharmacological models of psychosis, in first degree relatives of schizophrenic patients, and also in the general population associated with schizotypal dimensions. These results support a relationship between source monitoring deficits and some of the symptomatic dimensions of the schizophrenic spectrum but still await replication. Some studies found source monitoring deficits in other psychiatric conditions such as mania or obsessive-compulsive disorder. Thus, those studies suggest that source monitoring deficits may be not specific to schizophrenia. Source monitoring competencies are critical for good (i.e. adapted) everyday functioning. Source monitoring deficits have been suggested as a potential explanation for some (or all) positive psychotic symptoms. However, to date, methodological inconsistencies (especially with regard to test design and choice of subjects' samples) have precluded firm, definite conclusions. Copyright © 2010 L’Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.
Monitoring external and internal loads of brazilian soccer referees during official matches.
Costa, Eduardo C; Vieira, Caio M A; Moreira, Alexandre; Ugrinowitsch, Carlos; Castagna, Carlo; Aoki, Marcelo S
2013-01-01
This study aimed to assess the external and internal loads of Brazilian soccer referees during official matches. A total of 11 field referees (aged 36.2 ± 7.5 years) were monitored during 35 matches. The external (distance covered, mean and maximal speed) and internal load parameters (session ratings of perceived exertion [RPE] training load [TL], Edwards' TL, and time spent in different heart rate [HR] zones) were assessed in 3-4 matches per referee. External load parameters were measured using a wrist Global Positioning System (GPS) receiver. No differences in distance covered (5.219 ± 205 vs. 5.230 ± 237 m) and maximal speed (19.3 ± 1.0 vs. 19.4 ± 1.4 km·h(-1)) were observed between the halves of the matches (p > 0.05). However, the mean speed was higher in the first half of the matches (6.6 ± 0.4 vs. 6.4 ± 0.3 km·h(-1)) (p < 0.05) than in the second half. The mean HR during the matches was ~89% of HRmax. In ~95% of the matches, the referees demonstrated a HR ≥ 80% of HRmax. Nonetheless, the time spent at 90-100% of HRmax was higher in the first half (59.9 vs. 52.3%) (p < 0.05). Significant correlations between session RPE TL and distance covered at 90-100% of HRmax (r = 0.62) and session RPE TL and maximal speed (r = 0.54) (p < 0.05) were noted. Furthermore, there was a positive correlation between session RPE TL and Edwards' TL (r = 0.61) (p < 0.05). Brazilian soccer referees demonstrated high external and internal load demands during official matches. The portable GPS/HR monitors and session RPE method can provide relevant information regarding the magnitude of the physiological strain during official matches. Key PointsHigh external and internal loads were imposed on Brazilian soccer referees during official matches.There was a high positive correlation between a subjective marker of internal load (session RPE) and parameters of external load (distance covered between 90-100% of HRmax and maximal speed).There was a high positive correlation between session RPE method and Edwards' method.Session RPE seems to be a reliable marker of internal load.The portable GPS/HR monitors and the session RPE method can provide relevant information regarding the magnitude of external and internal loads of soccer referees during official matches.
Noninvasive valve monitor using alternating electromagnetic field
Eissenberg, David M.; Haynes, Howard D.; Casada, Donald A.
1993-01-01
One or more electrical coils are carefully located on the outside of a valve body. An alternating current passing through the coil(s) results in an alternating electromagnetic field being transmitted into the valve body and valve internals. The electromagnetic field varies in intensity and polarity in the valve. As the position of a valve internal part is changed, the electromagnetic field throughout the valve body and its internals is altered. A passive receiver coil carefully located on the outside of the valve body detects the intensity of the electromagnetic field at that location as an induced electrical voltage in the coil. With the change in position of the valve internal part, there is a corresponding change in the induced voltage as a result of the alteration in the alternating electromagnetic field at that location. Changes in the voltage provide an indication of the position and motion of valve internals.
Noninvasive valve monitor using alternating electromagnetic field
Eissenberg, D.M.; Haynes, H.D.; Casada, D.A.
1993-03-16
One or more electrical coils are carefully located on the outside of a valve body. An alternating current passing through the coil(s) results in an alternating electromagnetic field being transmitted into the valve body and valve internals. The electromagnetic field varies in intensity and polarity in the valve. As the position of a valve internal part is changed, the electromagnetic field throughout the valve body and its internals is altered. A passive receiver coil carefully located on the outside of the valve body detects the intensity of the electromagnetic field at that location as an induced electrical voltage in the coil. With the change in position of the valve internal part, there is a corresponding change in the induced voltage as a result of the alteration in the alternating electromagnetic field at that location. Changes in the voltage provide an indication of the position and motion of valve internals.
Roman, S; Gyawali, C P; Savarino, E; Yadlapati, R; Zerbib, F; Wu, J; Vela, M; Tutuian, R; Tatum, R; Sifrim, D; Keller, J; Fox, M; Pandolfino, J E; Bredenoord, A J
2017-10-01
An international group of experts evaluated and revised recommendations for ambulatory reflux monitoring for the diagnosis of gastro-esophageal reflux disease (GERD). Literature search was focused on indications and technical recommendations for GERD testing and phenotypes definitions. Statements were proposed and discussed during several structured meetings. Reflux testing should be performed after cessation of acid suppressive medication in patients with a low likelihood of GERD. In this setting, testing can be either catheter-based or wireless pH-monitoring or pH-impedance monitoring. In patients with a high probability of GERD (esophagitis grade C and D, histology proven Barrett's mucosa >1 cm, peptic stricture, previous positive pH monitoring) and persistent symptoms, pH-impedance monitoring should be performed on treatment. Recommendations are provided for data acquisition and analysis. Esophageal acid exposure is considered as pathological if acid exposure time (AET) is greater than 6% on pH testing. Number of reflux episodes and baseline impedance are exploratory metrics that may complement AET. Positive symptom reflux association is defined as symptom index (SI) >50% or symptom association probability (SAP) >95%. A positive symptom-reflux association in the absence of pathological AET defines hypersensitivity to reflux. The consensus group determined that grade C or D esophagitis, peptic stricture, histology proven Barrett's mucosa >1 cm, and esophageal acid exposure greater >6% are sufficient to define pathological GERD. Further testing should be considered when none of these criteria are fulfilled. © 2017 John Wiley & Sons Ltd.
Performance monitoring for brain-computer-interface actions.
Schurger, Aaron; Gale, Steven; Gozel, Olivia; Blanke, Olaf
2017-02-01
When presented with a difficult perceptual decision, human observers are able to make metacognitive judgements of subjective certainty. Such judgements can be made independently of and prior to any overt response to a sensory stimulus, presumably via internal monitoring. Retrospective judgements about one's own task performance, on the other hand, require first that the subject perform a task and thus could potentially be made based on motor processes, proprioceptive, and other sensory feedback rather than internal monitoring. With this dichotomy in mind, we set out to study performance monitoring using a brain-computer interface (BCI), with which subjects could voluntarily perform an action - moving a cursor on a computer screen - without any movement of the body, and thus without somatosensory feedback. Real-time visual feedback was available to subjects during training, but not during the experiment where the true final position of the cursor was only revealed after the subject had estimated where s/he thought it had ended up after 6s of BCI-based cursor control. During the first half of the experiment subjects based their assessments primarily on the prior probability of the end position of the cursor on previous trials. However, during the second half of the experiment subjects' judgements moved significantly closer to the true end position of the cursor, and away from the prior. This suggests that subjects can monitor task performance when the task is performed without overt movement of the body. Copyright © 2016 Elsevier Inc. All rights reserved.
Noninvasive valve monitor using constant magnetic and/or DC electromagnetic field
Casada, D.A.; Haynes, H.D.
1993-08-17
One or more sources of steady magnetic field are carefully located on the outside of a valve body. The constant magnetic field is transmitted into the valve body and valve internals. A magnetic field detector carefully located on the outside of the valve body detects the intensity of the magnetic field at its location. As the position of a valve internal part is changed, there is an alteration in the magnetic field in the valve, and a consequent change in the detected magnetic field. Changes in the detected signal provide an indication of the position and motion of the valve internals.
Noninvasive valve monitor using constant magnetic and/or DC electromagnetic field
Casada, Donald A.; Haynes, Howard D.
1993-01-01
One or more sources of steady magnetic field are carefully located on the outside of a valve body. The constant magnetic field is transmitted into the valve body and valve internals. A magnetic field detector carefully located on the outside of the valve body detects the intensity of the magnetic field at its location. As the position of a valve internal part is changed, there is an alteration in the magnetic field in the valve, and a consequent change in the detected magnetic field. Changes in the detected signal provide an indication of the position and motion of the valve internals.
NASA Astrophysics Data System (ADS)
Borncamp, David
2017-08-01
The stability of the CCD flat fields will be monitored using the calibration lamps. One set of observations for all the filters and another at a different epoch for a subset of filters will be taken during this cycle. High signal observations will be used to assess the stability of the pixel-to-pixel flat field structure and to monitor the position of the dust motes.
NASA Astrophysics Data System (ADS)
Borncamp, David
2016-10-01
The stability of the CCD flat fields will be monitored using the calibration lamps. One set of observations for all the filters and another at a different epoch for a subset of filters will be taken during this cycle. High signal observations will be used to assess the stability of the pixel-to-pixel flat field structure and to monitor the position of the dust motes.
Cycle 24 COS FUV Internal/External Wavelength Scale Monitor
NASA Astrophysics Data System (ADS)
Fischer, William J.
2018-02-01
We report on the monitoring of the COS FUV wavelength scale zero-points during Cycle 24 in program 14855. Select cenwaves were monitored for all FUV gratings at Lifetime Position 3. The target and cenwaves have remained the same since Cycle 21, with a change only to the target acquisition sequence. All measured offsets are within the error goals, although the G140L cenwaves show offsets at the short-wavelength end of segment A that are approaching the tolerance. This behavior will be closely monitored in subsequent iterations of the program.
Constrained optimization for position calibration of an NMR field camera.
Chang, Paul; Nassirpour, Sahar; Eschelbach, Martin; Scheffler, Klaus; Henning, Anke
2018-07-01
Knowledge of the positions of field probes in an NMR field camera is necessary for monitoring the B 0 field. The typical method of estimating these positions is by switching the gradients with known strengths and calculating the positions using the phases of the FIDs. We investigated improving the accuracy of estimating the probe positions and analyzed the effect of inaccurate estimations on field monitoring. The field probe positions were estimated by 1) assuming ideal gradient fields, 2) using measured gradient fields (including nonlinearities), and 3) using measured gradient fields with relative position constraints. The fields measured with the NMR field camera were compared to fields acquired using a dual-echo gradient recalled echo B 0 mapping sequence. Comparisons were done for shim fields from second- to fourth-order shim terms. The position estimation was the most accurate when relative position constraints were used in conjunction with measured (nonlinear) gradient fields. The effect of more accurate position estimates was seen when compared to fields measured using a B 0 mapping sequence (up to 10%-15% more accurate for some shim fields). The models acquired from the field camera are sensitive to noise due to the low number of spatial sample points. Position estimation of field probes in an NMR camera can be improved using relative position constraints and nonlinear gradient fields. Magn Reson Med 80:380-390, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Bares, Cristina B.; Andrade, Fernando; Delva, Jorge; Grogan-Kaylor, Andrew
2011-01-01
Considerable research in the U.S. has established that adolescent antisocial, aggressive, and attention problems have a negative influence on adolescents' ability to become productive members of society. However, although these behaviors appear in other cultures, little is known about the development of these problems among adolescents in countries other than the U.S.. This study contributes to our understanding of personality and parenting factors associated with adolescent problem behaviors using an international sample. Data are from a NIDA-funded study of 884 community-dwelling adolescents in Santiago, Chile (Mean age=14, SD=1.4, 48% females) of mid-to-low socioeconomic status. Results revealed that rule-breaking and aggressive behaviors were both associated with greater levels of adolescent drive but lower levels of parental monitoring and positive parenting by both parents. Adolescents who reported more attention problems were more likely to exhibit driven behavior, more behavioral inhibition, to report lower levels of parental monitoring, and positive parenting by mother and father. Results of interactions revealed that the influences of positive parenting and parental monitoring on adolescent aggressive behaviors varied as a function of the gender of the adolescent. Helping parents build on their parenting skills may result in important reductions in adolescent problem behaviors among U.S. and international adolescents. PMID:23100999
NASA Technical Reports Server (NTRS)
Kessel, C.; Wickens, C. D.
1978-01-01
The development of the internal model as it pertains to the detection of step changes in the order of control dynamics is investigated for two modes of participation: whether the subjects are actively controlling those dynamics or are monitoring an autopilot controlling them. A transfer of training design was used to evaluate the relative contribution of proprioception and visual information to the overall accuracy of the internal model. Sixteen subjects either tracked or monitored the system dynamics as a 2-dimensional pursuit display under single task conditions and concurrently with a sub-critical tracking task at two difficulty levels. Detection performance was faster and more accurate in the manual as opposed to the autopilot mode. The concurrent tracking task produced a decrement in detection performance for all conditions though this was more marked for the manual mode. The development of an internal model in the manual mode transferred positively to the automatic mode producing enhanced detection performance. There was no transfer from the internal model developed in the automatic mode to the manual mode.
A novel modality for intrapartum fetal heart rate monitoring.
Ashwal, Eran; Shinar, Shiri; Aviram, Amir; Orbach, Sharon; Yogev, Yariv; Hiersch, Liran
2017-11-02
Intrapartum fetal heart rate (FHR) monitoring is well recommended during labor to assess fetal wellbeing. Though commonly used, the external Doppler and fetal scalp electrode monitor have significant shortcomings. Lately, non-invasive technologies were developed as possible alternatives. The objective of this study is to compare the accuracy of FHR trace using novel Electronic Uterine Monitoring (EUM) to that of external Doppler and fetal scalp electrode monitor. A comparative study conducted in a single tertiary medical center. Intrapartum FHR trace was recorded simultaneously using three different methods: internal fetal scalp electrode, external Doppler, and EUM. The latter, a multichannel electromyogram (EMG) device acquires a uterine signal and maternal and fetal electrocardiograms. FHR traces obtained from all devices during the first and second stages of labor were analyzed. Positive percent of agreement (PPA) and accuracy (by measuring root means square error between observed and predicted values) of EUM and external Doppler were both compared to internal scalp electrode monitoring. A Bland-Altman agreement plot was used to compare the differences in FHR trace between all modalities. For momentary recordings of fetal heart rate <110 bpm or >160 bpm level of agreement, sensitivity, and specificity were also evaluated. Overall, 712,800 FHR momentary recordings were obtained from 33 parturients. Although both EUM and external Doppler highly correlated with internal scalp electrode monitoring (r 2 = 0.98, p < .001 for both methods), the accuracy of EUM was significantly higher than external Doppler (99.0% versus 96.6%, p < .001). In addition, for fetal heart rate <110 bpm or >160 bpm, the PPA, sensitivity, and specificity of EUM as compared with internal fetal scalp electrode, were significantly greater than those of external Doppler (p < .001). Intrapartum FHR using EUM is both valid and accurate, yielding higher correlations with internal scalp electrode monitoring than external Doppler. As such, it may provide a good framework for non-invasive evaluation of intrapartum FHR.
A metrology system for a high resolution cavity beam position monitor system
NASA Astrophysics Data System (ADS)
Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Hinton, Shantell; Honda, Yosuke; Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen
2013-11-01
International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved-ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.
Lew, S; Hämäläinen, M S; Okada, Y
2017-12-01
To evaluate whether a full-coverage fetal-maternal scanner can noninvasively monitor ongoing electrophysiological activity of maternal and fetal organs. A simulation study was carried out for a scanner with an array of magnetic field sensors placed all around the torso from the chest to the hip within a horizontal magnetic shielding enclosure. The magnetic fields from internal organs and an external noise source were computed for a pregnant woman with a 35-week old fetus. Signal processing methods were used to reject the external and internal interferences, to visualize uterine activity, and to detect activity of fetal heart and brain. External interference was reduced by a factor of 1000, sufficient for detecting signals from internal organs when combined with passive and active shielding. The scanner rejects internal interferences better than partial-coverage arrays. It can be used to estimate currents around the uterus. It clearly detects spontaneous activity from the fetal heart and brain without averaging and weaker evoked brain activity at all fetal head positions after averaging. The simulated device will be able to monitor the ongoing activity of the fetal and maternal organs. This type of scanner may become a novel tool in fetal medicine. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Cohen, Wayne R; Hayes-Gill, Barrie
2014-06-01
To evaluate the performance of external electronic fetal heart rate and uterine contraction monitoring according to maternal body mass index. Secondary analysis of prospective equivalence study. Three US urban teaching hospitals. Seventy-four parturients with a normal term pregnancy. The parent study assessed performance of two methods of external fetal heart rate monitoring (abdominal fetal electrocardiogram and Doppler ultrasound) and of uterine contraction monitoring (electrohystero-graphy and tocodynamometry) compared with internal monitoring with fetal scalp electrode and intrauterine pressure transducer. Reliability of external techniques was assessed by the success rate and positive percent agreement with internal methods. Bland-Altman analysis determined accuracy. We analyzed data from that study according to maternal body mass index. We assessed the relationship between body mass index and monitor performance with linear regression, using body mass index as the independent variable and measures of reliability and accuracy as dependent variables. There was no significant association between maternal body mass index and any measure of reliability or accuracy for abdominal fetal electrocardiogram. By contrast, the overall positive percent agreement for Doppler ultrasound declined (p = 0.042), and the root mean square error from the Bland-Altman analysis increased in the first stage (p = 0.029) with increasing body mass index. Uterine contraction recordings from electrohysterography and tocodynamometry showed no significant deterioration related to maternal body mass index. Accuracy and reliability of fetal heart rate monitoring using abdominal fetal electrocardiogram was unaffected by maternal obesity, whereas performance of ultrasound degraded directly with maternal size. Both electrohysterography and tocodynamometry were unperturbed by obesity. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.
Development of an S-band cavity Beam Position Monitor for ATF2
NASA Astrophysics Data System (ADS)
Heo, A.; Kim, E.-S.; Kim, H.; Son, D.; Honda, Y.; Tauchi, T.
2013-04-01
We have developed an S-band cavity Beam Position Monitor (BPM) in order to measure the position of an electron beam in the final focus area at ATF2, which is the test facility for the final focus design for the International Linear Collider (ILC). The lattice of the ILC Beam Delivery System (BDS) has been modified, requiring a larger physical aperture of 40 mm in the final focus area. The beam orbit measurement in this area is now covered with high resolution S-Band cavity BPMs. In this paper we summarize the design of the cavity BPM and the first experimental results. The calibration slopes were measured as 0.87 counts/μm in the x-coordinate direction and 1.16 counts/μm in the y-coordinate direction.
Characterization of the International Linear Collider damping ring optics
NASA Astrophysics Data System (ADS)
Shanks, J.; Rubin, D. L.; Sagan, D.
2014-10-01
A method is presented for characterizing the emittance dilution and dynamic aperture for an arbitrary closed lattice that includes guide field magnet errors, multipole errors and misalignments. This method, developed and tested at the Cornell Electron Storage Ring Test Accelerator (CesrTA), has been applied to the damping ring lattice for the International Linear Collider (ILC). The effectiveness of beam based emittance tuning is limited by beam position monitor (BPM) measurement errors, number of corrector magnets and their placement, and correction algorithm. The specifications for damping ring magnet alignment, multipole errors, number of BPMs, and precision in BPM measurements are shown to be consistent with the required emittances and dynamic aperture. The methodology is then used to determine the minimum number of position monitors that is required to achieve the emittance targets, and how that minimum depends on the location of the BPMs. Similarly, the maximum tolerable multipole errors are evaluated. Finally, the robustness of each BPM configuration with respect to random failures is explored.
International Collaboration in Space Weather Situational Awareness
NASA Astrophysics Data System (ADS)
Boteler, David; Trichtchenko, Larisa; Danskin, Donald
Space weather is a global phenomena so interntional collaboration is necessary to maintain awareness of potentially dangerous conditions. The Regional Warning Centres (RWCs) of the International Space Environment Service were set up during the International Geophysical Year to alert the scientific community to conditions requiring special measurements. The information sharing continues to this day with URSIGRAM messages exchanged between RWCs to help them produce space weather forecasts. Venturing into space, especially with manned missions, created a need to know about the space environment and particularly radiation dangers to man in space. Responding to this need led to the creation of a network of stations around the world to provide continuous monitoring of solar activity. Solar wind monitoring is now provided by the ACE satellite, operated by one country, but involving international collaborators to bring the information down in real time. Disturbances in the Earth's magnetic field are monitored by many magnetic observatories that are collaborating through INTERMAGNET to provide reliable data. Space weather produces effects on the ionosphere that can interfere with a variety of systems: the International GNSS Service provides information about effects on positioning systems, and the International Space Environment Service is providing information about iono-spheric absorption, particularly for trans-polar airline operations. The increasing availability of internet access, even at remote locations, is making it easier to obtain the raw information. The challenge now is how to integrate that information to provide effective international situational awareness of space weather.
Higham, Dean G; Pyne, David B; Anson, Judith M; Hopkins, Will G; Eddy, Anthony
2016-05-01
The specificity of contemporary training practices of international rugby sevens players is unknown. We quantified the positional group-specific activity profiles and physiological demands of on-field training activities and compared these with match demands. Twenty-two international matches and 63 rugby-specific training drills were monitored in 25 backs and 17 forwards from a national squad of male rugby sevens players over a 21-month period. Drills were classified into 3 categories: low-intensity skill refining (n = 23 drills, 560 observations), moderate- to high-intensity skill refining (n = 28 drills, 600 observations), and game simulation (n = 12 drills, 365 observations). Movement patterns (via Global Positioning System devices) and physiological load (via heart rate monitors) were recorded for all activities, and the differences between training and matches were quantified using magnitude-based inferential statistics. Distance covered in total and at ≥3.5 m·s, maximal velocity, and frequency of accelerations and decelerations were lower for forwards during competition compared with those for backs by a small but practically important magnitude. No clear positional group differences were observed for physiological load during matches. Training demands exceeded match demands only for frequency of decelerations of forwards during moderate- to high-intensity skill-refining drills and only by a small amount. Accelerations and distance covered at ≥6 m·s were closer to match values for forwards than for backs during all training activities, but training drills consistently fell below the demands of international competition. Coaches could therefore improve physical and physiological specificity by increasing the movement demands and intensity of training drills.
Environment Canada cuts threaten the future of science and international agreements
NASA Astrophysics Data System (ADS)
Thompson, Anne M.; Salawitch, Ross J.; Hoff, Raymond M.; Logan, Jennifer A.; Einaudi, Franco
2012-02-01
In August 2011, 300 Environment Canada scientists and staff working on environmental monitoring and protection learned that their jobs would be terminated, and an additional 400-plus Environment Canada employees received notice that their positions were targeted for elimination. These notices received widespread coverage in the Canadian media and international attention in Nature News. Environment Canada is a government agency responsible for meteorological services as well as environmental research. We are concerned that research and observations related to ozone depletion, tropospheric pollution, and atmospheric transport of toxic chemicals in the northern latitudes may be seriously imperiled by the budget cuts that led to these job terminations. Further, we raise the questions being asked by the international community, scientists, and policy makers alike: First, will Canada be able to meet its obligations to the monitoring and assessment studies that support the various international agreements inTable 1? Second, will Canada continue to be a leader in Arctic research.
Understanding Resilience in Educational Trajectories: Implications for Protective Possibilities
ERIC Educational Resources Information Center
Morrison, Gale M.; Brown, Megan; D'Incau, Barbara; O'Farrell, Stacy Larson; Furlong, Michael J.
2006-01-01
A growing body of literature on risk and resilience, school engagement, and positive psychology offers school psychologists new perspectives with which to consider students' progress through school. This literature emphasizes the importance of monitoring student internal and external assets. In this article, a framework is reviewed that highlights…
Fetal heart rate monitoring of short term variation (STV): a methodological observational study.
Wretler, Stina; Holzmann, Malin; Graner, Sophie; Lindqvist, Pelle; Falck, Susanne; Nordström, Lennart
2016-03-16
Cardiotocography (CTG) has high sensitivity, but less specificity in detection of fetal hypoxia. There is need for adjunctive methods easy to apply during labor. Low fetal heart rate short term variation (STV) is predictive for hypoxia during the antenatal period. The objectives of our study were to methodologically evaluate monitoring of STV during labor and to compare two different monitors (Sonicaid™ and EDAN™) for antenatal use. A prospective observational study at the obstetric department, Karolinska University hospital, Stockholm (between September 2011 and April 2015). In 100 women of ≥ 36 weeks gestation, STV values were calculated during active labor. In a subset of 20 women we compared STV values between internal and external signal acquisition. Additionally we compared antenatal monitoring with two different monitors in another 20 women. Median STV in 100 fetuses monitored with scalp electrode during labor (EDAN™) was 7.1 msec (range 1.3-25.9) with no difference between early (3-6 cm) and late (7-10 cm) labor (7.1 vs 6.8 msec; p = 0.80). STV calculated from scalp electrode signals were positively correlated with delta-STV (STV internal -external) (R = 0.70; p < 0.01). No significant differences were found between Sonicaid™ and EDAN™ in antenatal external monitoring of STV (median difference 0.9 msec, Spearman Rank Correlation Sonicaid vs delta-STV; R = 0.35; p = 0.14). Median intrapartum STV was 7.1 msec. Significant differences were found between internal and external signal acquisition, a finding that suggests further intrapartum studies to be analysed separately depending upon type of signal acquisition. Antenatal external monitoring with Sonicaid™ and EDAN™ indicates that the devices perform equally well in the identification of acidemic fetuses. Further studies are needed to assess the clinical value of intrapartum STV.
Rakow, Aaron; McKee, Laura; Coffelt, Nicole; Champion, Jennifer; Fear, Jessica; Compas, Bruce
2009-01-01
The purpose of this study was to examine the relation between parental guilt induction and child internalizing problems in families where a caregiver had experienced depression. A total of 107 families, including 146 children (age 9–15), participated. Child-reported parental guilt induction, as well as three more traditionally studied parenting behaviors (warmth/involvement, monitoring, and discipline), were assessed, as was parent-report of child internalizing problem behavior. Linear Mixed Models Analysis indicated parental guilt induction was positively related to child internalizing problems in the context of the remaining three parenting behaviors. Implications of the findings for prevention and intervention parenting programs are considered. PMID:20090863
Error-Related Psychophysiology and Negative Affect
ERIC Educational Resources Information Center
Hajcak, G.; McDonald, N.; Simons, R.F.
2004-01-01
The error-related negativity (ERN/Ne) and error positivity (Pe) have been associated with error detection and response monitoring. More recently, heart rate (HR) and skin conductance (SC) have also been shown to be sensitive to the internal detection of errors. An enhanced ERN has consistently been observed in anxious subjects and there is some…
Acoustic Measurement Of Periodic Motion Of Levitated Object
NASA Technical Reports Server (NTRS)
Watkins, John L.; Barmatz, Martin B.
1992-01-01
Some internal vibrations, oscillations in position, and rotations of acoustically levitated object measured by use of microphone already installed in typical levitation chamber for tuning chamber to resonance and monitoring operation. Levitating acoustic signal modulated by object motion of lower frequency. Amplitude modulation detected and analyzed spectrally to determine amplitudes and frequencies of motions.
Górecki, Kamil; Hägerhäll, Cecilia; Drakenberg, Torbjörn
2014-01-15
(23)Na nuclear magnetic resonance (NMR) has previously been used to monitor Na(+) translocation across membranes in gram-negative bacteria and in various other organelles and liposomes using a membrane-impermeable shift reagent to resolve the signals resulting from internal and external Na(+). In this work, the (23)Na NMR method was adapted for measurements of internal Na(+) concentration in the gram-positive bacterium Bacillus subtilis, with the aim of assessing the Na(+) translocation activity of the Mrp (multiple resistance and pH) antiporter complex, a member of the cation proton antiporter-3 (CPA-3) family. The sodium-sensitive growth phenotype observed in a B. subtilis strain with the gene encoding MrpA deleted could indeed be correlated to the inability of this strain to maintain a lower internal Na(+) concentration than an external one. Copyright © 2013 Elsevier Inc. All rights reserved.
Williams, J D; Lehman, R
1988-01-01
A technique is described in which "jingle bells" are sutured in three positions on the face at the points of maximum excursion of the facial musculature when stimulated by a Hilger nerve stimulator set at 2 mA. The procedure is used to monitor movement of the facial nerve while the surgeon dissects the nerve in the cerebellopontine angle and internal auditory canal.
NASA Astrophysics Data System (ADS)
Kim, K. T.; Kim, J. H.; Han, M. J.; Heo, Y. J.; Park, S. K.
2018-02-01
Imaging technology based on gamma-ray sources has been extensively used in non-destructive testing (NDT) to detect any possible internal defects in products without changing their shapes or functions. However, such technology has been subject to increasingly stricter regulations, and an international radiation-safety management system has been recently established. Consequently, radiation source location in NDT systems has become an essential process, given that it can prevent radiation accidents. In this study, we focused on developing a monitoring system that can detect, in real time, the position of a radioactive source in the source guide tube of a projector. We fabricated a lead iodide (PbI2) dosimeter based on the particle-in-binder method, which has a high production yield and facilitates thickness and shape adjustment. Using a gamma-ray source, we then tested the reproducibility, linearity of the dosimeter response, and the dosimeter's percentage interval distance (PID). It was found that the fabricated PbI2 dosimeter yields highly accurate, reproducible, and linear dose measurements. The PID analysis—conducted to investigate the possibility of developing a monitoring system based on the proposed dosimeter—indicated that the valid detection distance was approximately 11.3 cm. The results of this study are expected to contribute to the development of an easily usable radiation monitoring system capable of significantly reducing the risk of radiation accidents.
Shinto, K; Senée, F; Ayala, J-M; Bolzon, B; Chauvin, N; Gobin, R; Ichimiya, R; Ihara, A; Ikeda, Y; Kasugai, A; Kitano, T; Kondo, K; Marqueta, A; Okumura, Y; Takahashi, H; Valette, M
2016-02-01
Ion species ratio of high current positive hydrogen/deuterium ion beams extracted from an electron-cyclotron-resonance ion source for International Fusion Materials Irradiation Facility accelerator was measured by the Doppler shift Balmer-α line spectroscopy. The proton (H(+)) ratio at the middle of the low energy beam transport reached 80% at the hydrogen ion beam extraction of 100 keV/160 mA and the deuteron (D(+)) ratio reached 75% at the deuterium ion beam extraction of 100 keV/113 mA. It is found that the H(+) ratio measured by the spectroscopy gives lower than that derived from the phase-space diagram measured by an Allison scanner type emittance monitor. The H(+)/D(+) ratio estimated by the emittance monitor was more than 90% at those extraction currents.
Theoretical studies of floating-reference method for NIR blood glucose sensing
NASA Astrophysics Data System (ADS)
Shi, Zhenzhi; Yang, Yue; Zhao, Huijuan; Chen, Wenliang; Liu, Rong; Xu, Kexin
2011-03-01
Non-invasive blood glucose monitoring using NIR light has been suffered from the variety of optical background that is mainly caused by the change of human body, such as the change of temperature, water concentration, and so on. In order to eliminate these internal influence and external interference a so called floating-reference method has been proposed to provide an internal reference. From the analysis of the diffuse reflectance spectrum, a position has been found where diffuse reflection of light is not sensitive to the glucose concentrations. Our previous work has proved the existence of reference position using diffusion equation. However, since glucose monitoring generally use the NIR light in region of 1000-2000nm, diffusion equation is not valid because of the high absorption coefficient and small source-detector separations. In this paper, steady-state high-order approximate model is used to further investigate the existence of the floating reference position in semi-infinite medium. Based on the analysis of different optical parameters on the impact of spatially resolved reflectance of light, we find that the existence of the floating-reference position is the result of the interaction of optical parameters. Comparing to the results of Monte Carlo simulation, the applicable region of diffusion approximation and higher-order approximation for the calculation of floating-reference position is discussed at the wavelength of 1000nm-1800nm, using the intralipid solution of different concentrations. The results indicate that when the reduced albedo is greater than 0.93, diffusion approximation results are more close to simulation results, otherwise the high order approximation is more applicable.
Zhang, Di; Fu, Hui-Zhen; Ho, Yuh-Shan
2017-11-01
A bibliometric analysis based on the Science Citation Index Expanded from Web of Science was carried out to provide insights into research activities and trends of the environmental monitoring from 1993 to 2012. Study emphases covered publication outputs, language, categories, journals, countries/territories, institutions, words, and hot issues. The results indicated that the annual output of environmental monitoring publications increased steadily. The environmental sciences and analytical chemistry were the two most common categories. Environmental Monitoring and Assessment published the most articles. The USA and the UK ranked in the top two in terms of all five indicators. The U.S. Environmental Protection Agency took the leading position of the institutions in terms of publication output. The synthesized analysis by words in title, author keywords, and KeyWords Plus provided important clues for hot issues. Researchers paid more attention on water environment monitoring than other environmental factors. The contaminants including organic contaminants, heavy metal, and radiation were most common research focuses, and the organic contaminants and heavy metal of the degree of concern were gradually rising. Sensor and biosensor played an important role in the field of environmental monitoring devices. In addition to conventional device detection method, the remote sensing, GIS, and wireless sensor networks were the mainstream environmental monitoring methods. The international organization, social awareness, and the countries' positive and effective political and policies promoted the published articles.
NASA Astrophysics Data System (ADS)
Krauss, Andreas; Fast, Martin F.; Nill, Simeon; Oelfke, Uwe
2012-04-01
We have previously developed a tumour tracking system, which adapts the aperture of a Siemens 160 MLC to electromagnetically monitored target motion. In this study, we exploit the use of a novel linac-mounted kilovoltage x-ray imaging system for MLC tracking. The unique in-line geometry of the imaging system allows the detection of target motion perpendicular to the treatment beam (i.e. the directions usually featuring steep dose gradients). We utilized the imaging system either alone or in combination with an external surrogate monitoring system. We equipped a Siemens ARTISTE linac with two flat panel detectors, one directly underneath the linac head for motion monitoring and the other underneath the patient couch for geometric tracking accuracy assessments. A programmable phantom with an embedded metal marker reproduced three patient breathing traces. For MLC tracking based on x-ray imaging alone, marker position was detected at a frame rate of 7.1 Hz. For the combined external and internal motion monitoring system, a total of only 85 x-ray images were acquired prior to or in between the delivery of ten segments of an IMRT beam. External motion was monitored with a potentiometer. A correlation model between external and internal motion was established. The real-time component of the MLC tracking procedure then relied solely on the correlation model estimations of internal motion based on the external signal. Geometric tracking accuracies were 0.6 mm (1.1 mm) and 1.8 mm (1.6 mm) in directions perpendicular and parallel to the leaf travel direction for the x-ray-only (the combined external and internal) motion monitoring system in spite of a total system latency of ˜0.62 s (˜0.51 s). Dosimetric accuracy for a highly modulated IMRT beam-assessed through radiographic film dosimetry-improved substantially when tracking was applied, but depended strongly on the respective geometric tracking accuracy. In conclusion, we have for the first time integrated MLC tracking with x-ray imaging in the in-line geometry and demonstrated highly accurate respiratory motion tracking.
40 CFR 63.7741 - What are the installation, operation, and maintenance requirements for my monitors?
Code of Federal Regulations, 2013 CFR
2013-07-01
...; and (2) Install and maintain CPMS to measure and record the pH of the scrubber blowdown according to the requirements in paragraph (e)(2)(i) through (iv) of this section. (i) Locate the pH sensor in a position that provides a representative measurement of the pH and that minimizes or eliminates internal and...
NASA Astrophysics Data System (ADS)
Nadhira, Vebi; Kurniadi, Deddy; Juliastuti, E.; Sutiswan, Adeline
2014-03-01
The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The object was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nadhira, Vebi, E-mail: vebi@tf.itb.ac.id; Kurniadi, Deddy, E-mail: vebi@tf.itb.ac.id; Juliastuti, E., E-mail: vebi@tf.itb.ac.id
The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The objectmore » was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.« less
Paganin, Maddalena; Fabbri, Giulia; Conter, Valentino; Barisone, Elena; Polato, Katia; Cazzaniga, Giovanni; Giraldi, Eugenia; Fagioli, Franca; Aricò, Maurizio; Valsecchi, Maria Grazia; Basso, Giuseppe
2014-11-01
Acute lymphoblastic leukemia (ALL) is the most common pediatric cancer. Monitoring minimal residual disease (MRD) by using real-time quantitative polymerase chain reaction (RQ-PCR) provides information for patient stratification and individual risk-directed treatment. Cooperative studies have documented that measurement of blast clearance from the bone marrow during and after induction therapy identifies patient populations with different risk of relapse. We explored the possible contribution of measurements of MRD during the course of treatment. We used RQ-PCR to detect MRD in 110 unselected patients treated in Italy in the International Collaborative Treatment Protocol for Children and Adolescents With Acute Lymphoblastic Leukemia (AIEOP-BFM ALL 2000). The trial took place in AIEOP centers during postinduction chemotherapy. Results were categorized as negative, low positive (below the quantitative range [< 5 × 10(-4)]), or high positive (≥ 5 × 10(-4)). Patients with at least one low-positive or high-positive result were assigned to the corresponding subgroup. Patients who tested high positive, low positive, or negative had significantly different cumulative incidences of leukemia relapse: 83.3%, 34.8%, and 8.6%, respectively (P < .001). Two thirds of positive cases were identified within 4 months after induction-consolidation therapy, suggesting that this time frame may be most suitable for cost-effective MRD monitoring, particularly in patients who did not clear their disease at the end of consolidation. These findings provide further insights into the dynamic of MRD and the ongoing effort to define molecular relapse in childhood ALL. © 2014 by American Society of Clinical Oncology.
Mala, George; Spigt, Mark G; Gidding, Luc G; Blanco, Roman; Dinant, Geert-Jan
2015-10-01
To determine quality of diagnosis and monitoring of treatment response of patients with smear-negative pulmonary tuberculosis (TB) compared with smear-positive cases in Ethiopia. A retrospective analysis of medical records of newly diagnosed pulmonary TB cases that were registered for taking anti-TB medication and had completed treatment between 2010 and 2012. We evaluated the percentage of cases that were managed according to the International Standards of Tuberculosis Care (ISTC) and compared smear-negative with smear-positive cases. We analysed 1168 cases of which 742 (64%) were sputum smear-negative cases. Chest radiography examination at diagnosis and microbiological testing at the end of the intensive phase of treatment was performed in a smaller proportion than in smear-positive TB cases (70% vs. 79%, P value <0.001) and (70% vs. 95%, P value <0.001), respectively. Clinical actions recommended in the ISTC are of greatest importance in minimising pitfalls in care of smear-negative TB yet were performed less often in smear-negative than smear-positive TB cases. © The Author(s) 2015.
Ionospheric TEC Weather Map Over South America
NASA Astrophysics Data System (ADS)
Takahashi, H.; Wrasse, C. M.; Denardini, C. M.; Pádua, M. B.; de Paula, E. R.; Costa, S. M. A.; Otsuka, Y.; Shiokawa, K.; Monico, J. F. Galera; Ivo, A.; Sant'Anna, N.
2016-11-01
Ionospheric weather maps using the total electron content (TEC) monitored by ground-based Global Navigation Satellite Systems (GNSS) receivers over South American continent, TECMAP, have been operationally produced by Instituto Nacional de Pesquisas Espaciais's Space Weather Study and Monitoring Program (Estudo e Monitoramento Brasileiro de Clima Especial) since 2013. In order to cover the whole continent, four GNSS receiver networks, (Rede Brasileiro de Monitoramento Contínuo) RBMC/Brazilian Institute for Geography and Statistics, Low-latitude Ionospheric Sensor Network, International GNSS Service, and Red Argentina de Monitoreo Satelital Continuo, in total 140 sites, have been used. TECMAPs with a time resolution of 10 min are produced in 12 h time delay. Spatial resolution of the map is rather low, varying between 50 and 500 km depending on the density of the observation points. Large day-to-day variabilities of the equatorial ionization anomaly have been observed. Spatial gradient of TEC from the anomaly trough (total electron content unit, 1 TECU = 1016 el m-2 (TECU) <10) to the crest region (TECU > 80) causes a large ionospheric range delay in the GNSS positioning system. Ionospheric plasma bubbles, their seeding and development, could be monitored. This plasma density (spatial and temporal) variability causes not only the GNSS-based positioning error but also radio wave scintillations. Monitoring of these phenomena by TEC mapping becomes an important issue for space weather concern for high-technology positioning system and telecommunication.
Peak Running Intensity of International Rugby: Implications for Training Prescription.
Delaney, Jace A; Thornton, Heidi R; Pryor, John F; Stewart, Andrew M; Dascombe, Ben J; Duthie, Grant M
2017-09-01
To quantify the duration and position-specific peak running intensities of international rugby union for the prescription and monitoring of specific training methodologies. Global positioning systems (GPS) were used to assess the activity profile of 67 elite-level rugby union players from 2 nations across 33 international matches. A moving-average approach was used to identify the peak relative distance (m/min), average acceleration/deceleration (AveAcc; m/s 2 ), and average metabolic power (P met ) for a range of durations (1-10 min). Differences between positions and durations were described using a magnitude-based network. Peak running intensity increased as the length of the moving average decreased. There were likely small to moderate increases in relative distance and AveAcc for outside backs, halfbacks, and loose forwards compared with the tight 5 group across all moving-average durations (effect size [ES] = 0.27-1.00). P met demands were at least likely greater for outside backs and halfbacks than for the tight 5 (ES = 0.86-0.99). Halfbacks demonstrated the greatest relative distance and P met outputs but were similar to outside backs and loose forwards in AveAcc demands. The current study has presented a framework to describe the peak running intensities achieved during international rugby competition by position, which are considerably higher than previously reported whole-period averages. These data provide further knowledge of the peak activity profiles of international rugby competition, and this information can be used to assist coaches and practitioners in adequately preparing athletes for the most demanding periods of play.
Lewiecki, E Michael; Compston, Juliet E; Miller, Paul D; Adachi, Jonathan D; Adams, Judith E; Leslie, William D; Kanis, John A; Moayyeri, Alireza; Adler, Robert A; Hans, Didier B; Kendler, David L; Diez-Perez, Adolfo; Krieg, Marc-Antoine; Masri, Basel K; Lorenc, Roman R; Bauer, Douglas C; Blake, Glen M; Josse, Robert G; Clark, Patricia; Khan, Aliya A
2011-01-01
Tools to predict fracture risk are useful for selecting patients for pharmacological therapy in order to reduce fracture risk and redirect limited healthcare resources to those who are most likely to benefit. FRAX® is a World Health Organization fracture risk assessment algorithm for estimating the 10-year probability of hip fracture and major osteoporotic fracture. Effective application of FRAX® in clinical practice requires a thorough understanding of its limitations as well as its utility. For some patients, FRAX® may underestimate or overestimate fracture risk. In order to address some of the common issues encountered with the use of FRAX® for individual patients, the International Society for Clinical Densitometry (ISCD) and International Osteoporosis Foundation (IOF) assigned task forces to review the medical evidence and make recommendations for optimal use of FRAX® in clinical practice. Among the issues addressed were the use of bone mineral density (BMD) measurements at skeletal sites other than the femoral neck, the use of technologies other than dual-energy X-ray absorptiometry, the use of FRAX® without BMD input, the use of FRAX® to monitor treatment, and the addition of the rate of bone loss as a clinical risk factor for FRAX®. The evidence and recommendations were presented to a panel of experts at the Joint ISCD-IOF FRAX® Position Development Conference, resulting in the development of Joint ISCD-IOF Official Positions addressing FRAX®-related issues. Copyright © 2011 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Real-time beam monitoring in scanned proton therapy
NASA Astrophysics Data System (ADS)
Klimpki, G.; Eichin, M.; Bula, C.; Rechsteiner, U.; Psoroulas, S.; Weber, D. C.; Lomax, A.; Meer, D.
2018-05-01
When treating cancerous tissues with protons beams, many centers make use of a step-and-shoot irradiation technique, in which the beam is steered to discrete grid points in the tumor volume. For safety reasons, the irradiation is supervised by an independent monitoring system validating cyclically that the correct amount of protons has been delivered to the correct position in the patient. Whenever unacceptable inaccuracies are detected, the irradiation can be interrupted to reinforce a high degree of radiation protection. At the Paul Scherrer Institute, we plan to irradiate tumors continuously. By giving up the idea of discrete grid points, we aim to be faster and more flexible in the irradiation. But the increase in speed and dynamics necessitates a highly responsive monitoring system to guarantee the same level of patient safety as for conventional step-and-shoot irradiations. Hence, we developed and implemented real-time monitoring of the proton beam current and position. As such, we read out diagnostic devices with 100 kHz and compare their signals against safety tolerances in an FPGA. In this paper, we report on necessary software and firmware enhancements of our control system and test their functionality based on three exemplary error scenarios. We demonstrate successful implementation of real-time beam monitoring and, consequently, compliance with international patient safety regulations.
Cervical osteotomy in ankylosing spondylitis: evaluation of new developments.
Langeloo, Danielle D; Journee, Henricus L; Pavlov, Paul W; de Kleuver, Marinus
2006-04-01
Cervical osteotomy can be performed on patients with cervical kyphosis due to ankylosing spondylitis. This study reviews the role of two new developments in cervical osteotomy surgery: internal fixation and transcranial electrical stimulated motor evoked potential monitoring (TES-MEP). From 1999 to 2004, 16 patients underwent a C7-osteotomy with internal fixation. In 11 patients, cervical osteotomy was performed in a sitting position with halo-cast immobilization (group S), five patients underwent surgery in prone position with Mayfield clamp fixation (group P). In group P, longer fusion towards T4-T6 could be obtained that created a more stable fixation. Therefore, post-operative immobilization protocol of group P was simplified from halo-cast to cervical orthosis. Consolidation was obtained in all patients without loss of correction. Post-operative chin-brow to vertical angle measured 5 degrees (range 0-15). TES-MEP was successfully performed during all surgical procedures. In total, nine neurological events were registered. Additional surgical intervention resulted in recovery of amplitudes in six of nine events. In two patients spontaneous recovery took place. One patient showed no recovery of amplitudes despite surgical intervention and a partial C6 spinal cord lesion occurred. We conclude that C7 osteotomy with internal fixation has been shown to be a reliable and stable technique. When surgery is performed the in prone position, distal fixation can be optimally obtained allowing post-operative treatment by cervical orthosis instead of a halo-cast. TES-MEP monitoring has been shown to be a reliable neuromonitoring technique with high clinical relevancy during cervical osteotomy because it allows timely intervention before occurrence of permanent cord damage in a large proportion of the patients.
Method and apparatus for non-invasive monitoring of blood glucose
Thomas, Graham H.; Watson, Roger M.; Noell, J. Oakey
1992-06-09
A new and improved method and apparatus are provided for non-invasive monitoring of changes in blood glucose concentration in a tissue specimen and particularly in an individual. The method uses acoustic velocity measurements for monitoring the effect of glucose concentration upon the density and adiabatic compressibility of the serum. In a preferred embodiment, the acoustic velocity measurements are made through the earlobe of a subject by means of an acoustic probe or monitor which includes a transducer for transmitting and receiving ultrasonic energy pulses to and from the blood flowing in the subject's earlobe and a reflector for facilitating reflection of the acoustic pulses from the blood. The probe is designed in such a way that when properly affixed to an ear, the transducer is positioned flush against the anterior portion of an earlobe while the reflector is positioned flush against the interior portion of the earlobe. A microthermocouple is provided on the probe for monitoring the internal temperature of the blood being sampled. An electrical system, essentially comprising a frequency generator, a time intervalometer and an oscilloscope, is linked to the glucose monitoring probe. The electrical system analyzes selected ones of the pulses reflected from the blood sample in order to determine therefrom the acoustic velocity of the blood which, in turn, provides a representation of the blood glucose concentration levels at the time of the acoustic velocity measurements.
The Risks and Benefits of Internal Monitors in Laboring Patients
Harper, Lorie M.; Shanks, Anthony L.; Tuuli, Methodius G.; Roehl, Kimberly A.; Cahill, Alison G.
2013-01-01
Objective To estimate the impact of internal monitors (fetal scalp electrodes [FSE] and intrauterine pressure catheters [IUPC]) on maternal and neonatal outcomes. Study Design Retrospective cohort of all women admitted for labor 2004–2008. Women with internal monitors (FSE, IUPC, or both) were compared to women without internal monitors. Maternal outcomes were maternal fever and cesarean delivery (CD). Neonatal outcomes were a composite of 5-minute Apgar≤3, cord pH<7.1, cord base excess <-12, or admission to level 3 nursery. Logistic regression was performed to estimate the impact of internal monitors while adjusting for confounding variables, including time in labor. Results Of 6,445 subjects, 3,944 (61.2%) had internal monitors. Women with internal monitors were more likely to develop a fever than women without internal monitors (11.7% versus 4.5%, adjusted odds ratio (AOR) 2.0, 95% confidence interval (CI) 1.6-2.5). FSE alone was not associated with an increased risk of fever (AOR 1.5, 95% CI 1.0-2.1), but IUPC alone was (AOR 2.4, 95% CI 1.8-3.2). The risk of CD was higher in women with internal monitors (18.6% versus 9.7%, AOR 1.3, 95% CI 1.0-1.5). Risk of CD was lower in women with FSE alone (AOR 0.5, 95% CI 0.4-0.7) but higher in women with both an FSE and IUPC (AOR 1.6, 95% CI 1.4-2.0). Risk of the composite neonatal outcome was not higher in women with internal monitors (3.3% versus 3.6%, AOR 0.8, 95% CI 0.6-1.1). Conclusions Routine use of IUPC in laboring patient should be avoided due to increased risk of maternal fever. PMID:23562354
A data-driven approach of load monitoring on laminated composite plates using support vector machine
NASA Astrophysics Data System (ADS)
Gwon, Y. S.; Fekrmandi, H.
2018-03-01
In this study, the surface response to excitation method (SuRE) is investigated using a data-driven method for load monitoring on a laminated composite plate structure. The SuRE method is an emerging approach in ultrasonic wavebased structural health monitoring (SHM) field. In this method, a range of high-frequency, surface-guided waves are excited on the structure using piezoceramic elements. The waves propagate on the structure and interact with internal or surface damages. Initially, a baseline data of the intact structure is created by measuring the frequency transfer function between the excitation and sensing point. The integrity of structure is evaluated by monitoring changes in the frequency spectrums. The SuRE method has effectively been used for a variety of SHM applications including the detection of loose bolts, delamination in composite structures, internal corrosion in pipelines, and load and impact monitoring. Data obtained using the SuRE method was used for identifying the location of the applied load on a laminated composite plate using Support Vector Machine (SVM). A set of two piezoelectric elements were attached on the surface of the plate. A sweep excitation (150-250 kHz) generated surface-guided waves, and the transmitted waves were monitored at the sensory positions. The reference data set was measured simultaneously from the sensors. The plate was subjected to static loads while health monitoring data was being captured using the SuRE method. The confusion matrix indicated that the model classified correctly with up to 99.8% accuracy.
Code of Federal Regulations, 2014 CFR
2014-01-01
... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...
Code of Federal Regulations, 2012 CFR
2012-01-01
... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...
Code of Federal Regulations, 2011 CFR
2011-01-01
... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...
Code of Federal Regulations, 2013 CFR
2013-01-01
... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...
Code of Federal Regulations, 2010 CFR
2010-01-01
... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...
Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study.
Miguel-Cruz, Antonio; Rios-Rincón, Adriana; Haugan, Gregory L
2014-03-01
To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT) for the service providers (either in-house or outsourced) were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.
Monitoring of stability of ASG-EUPOS network coordinates
NASA Astrophysics Data System (ADS)
Figurski, M.; Szafranek, K.; Wrona, M.
2009-04-01
ASG-EUPOS (Active Geodetic Network - European Position Determination System) is the national system of precise satellite positioning in Poland, which increases a density of regional and global GNSS networks and is widely used by public administration, national institutions, entrepreneurs and citizens (especially surveyors). In near future ASG-EUPOS is to take role of main national network. Control of proper activity of stations and realization of ETRS'89 is a necessity. User of the system needs to be sure that observations quality and coordinates accuracy are high enough. Coordinates of IGS (International GNSS Service) and EPN (European Permanent Network) stations are precisely determined and any changes are monitored all the time. Observations are verified before they are archived in regional and global databases. The same applies to ASG-EUPOS. This paper concerns standardization of GNSS observations from different stations (uniform adjustment), examination of solutions correctness according to IGS and EPN standards and stability of solutions and sites activity
An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
Al-Halhouli, Ala'aldeen; Demming, Stefanie; Alahmad, Laila; LIobera, Andreu; Büttgenbach, Stephanus
2014-01-01
This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of 33 μL/h based on internal co-immobilization of glucose oxidase (GOX) and horseradish peroxidase (HRP) on the internal PDMS surface of the reactor chamber. For this design, two co-immobilization methods, the simple adsorption and the covalent binding (PEG) methods were tested. Experiments showed successful results when using the covalent binding (PEG) method, where glucose concentrations up to 5 mM with a coefficient of determination (R2) of 0.99 and a limit of detection of 0.26 mM are detectable. The second design is a modified version of the internally immobilized sensor, where a microbead chamber and a beads filling channel are integrated into the sensor. This modification enabled external co-immobilization of enzymes covalently onto functionalized silica microbeads and allows binding a huge amount of HRP and GOX enzymes on the microbeads surfaces which increases the interaction area between immobilized enzymes and the analyte. This has a positive effect on the amount and rate of chemical reactions taking place inside the chamber. The sensor was tested under continuous glucose flow conditions and was found to be able to detect glucose concentrations up to 10 mM with R2 of 0.98 and a limit of detection of 0.7 mM. Such results are very promising for the application in photonic LOC systems used for online analysis. PMID:25157552
Verbal monitoring in Parkinson’s disease: A comparison between internal and external monitoring
Mertens, Jolien; Mariën, Peter; Santens, Patrick; Pickut, Barbara A.; Hartsuiker, Robert J.
2017-01-01
Patients with Parkinson’s disease (PD) display a variety of impairments in motor and non-motor language processes; speech is decreased on motor aspects such as amplitude, prosody and speed and on linguistic aspects including grammar and fluency. Here we investigated whether verbal monitoring is impaired and what the relative contributions of the internal and external monitoring route are on verbal monitoring in patients with PD relative to controls. Furthermore, the data were used to investigate whether internal monitoring performance could be predicted by internal speech perception tasks, as perception based monitoring theories assume. Performance of 18 patients with Parkinson’s disease was measured on two cognitive performance tasks and a battery of 11 linguistic tasks, including tasks that measured performance on internal and external monitoring. Results were compared with those of 16 age-matched healthy controls. PD patients and controls generally performed similarly on the linguistic and monitoring measures. However, we observed qualitative differences in the effects of noise masking on monitoring and disfluencies and in the extent to which the linguistic tasks predicted monitoring behavior. We suggest that the patients differ from healthy subjects in their recruitment of monitoring channels. PMID:28832595
Worm, Esben S; Høyer, Morten; Hansen, Rune; Larsen, Lars P; Weber, Britta; Grau, Cai; Poulsen, Per R
2018-06-01
Intrafraction motion can compromise the treatment accuracy in liver stereotactic body radiation therapy (SBRT). Respiratory gating can improve treatment delivery; however, gating based on external motion surrogates is inaccurate. The present study reports the use of Calypso-based internal electromagnetic motion monitoring for gated liver SBRT. Fifteen patients were included in a study of 3-fraction respiratory gated liver SBRT guided by 3 implanted electromagnetic transponders. The planning target volume was created by a 5-mm axial and 7-mm (n = 12) or 10-mm (n = 3) craniocaudal expansion of the clinical target volume (CTV) and covered with 67% of the prescribed CTV mean dose. Treatment was gated to the end-exhale phase of the respiratory cycle with beam-on when the target deviated <3 mm (left-right/anteroposterior) and 4 mm (craniocaudal) from the planned position, according to the monitored (25-Hz) transponder centroid position. The couch was adjusted remotely if baseline drifts >1 to 2 mm occurred. Log files of transponder motion were used to determine the geometric error and reconstruct the delivered CTV dose in the actual gated treatments and in simulated nongated treatments. No severe side effects were observed in relation to transponder implantation. All 45 treatment fractions were successfully guided using the Calypso system. The mean number of couch corrections during each gated fraction was 2.8 (range 0-7). The mean duty cycle during gated treatment was 62.5% (range 29.1%-84.9%). Without gating, the mean 3-dimensional geometric error during a fraction would have been 5.4 mm (range 2.7-12.1). Gating reduced this error to 2.0 mm (range 1.2-3.0). The patient mean reduction in minimum dose to 95% of the CTV relative to the planned dose was 6.0 percentage points (range 0.7-22.0) without gating and 0.8 percentage point (range 0.2-2.0) with gating. Gating using internal motion monitoring was successfully applied for liver SBRT. It markedly improved the geometric and dosimetric accuracy compared with nongated standard treatment. Copyright © 2018 Elsevier Inc. All rights reserved.
Coyne, Katherine; Mandalia, Sundhiya; McCullough, Sonya; Catalan, Jose; Noestlinger, Christiana; Colebunders, Robert; Asboe, David
2010-02-01
Erectile dysfunction is common in HIV-positive men who have sex with men (MSM). A standardized scale is needed to assess erectile function in clinical practice and research studies. The International Index of Erectile Function (IIEF) is a widely accepted tool for assessing erectile function designed for heterosexual men. We modified the tool for MSM. We present an analysis of internal consistency of the questionnaire in an HIV-positive cohort. The adapted questionnaire included modified questions within each of the five domains of the IIEF: (i) erectile function, (ii) intercourse satisfaction, (iii) orgasmic function, (iv) sexual desire, and (v) overall satisfaction with sex. MSM at seven European HIV treatment centers completed the questionnaire. Responses were analyzed for internal consistency using standardized Cronbach's alpha values within each of the five domains. A factor analysis was performed to confirm the domain structure of the questionnaire. Data from 486 MSM were analyzed. The factor analysis supported the domain structure described. Questions about erectile function, orgasmic function, and sexual desire performed well, with Cronbach's alpha values of 0.82, 0.83, and 0.89, respectively. Questions concerning intercourse satisfaction were less consistent (Cronbach's alpha 0.55) because frequency of attempts at sexual intercourse did not correlate with other responses. Responses about satisfaction with sex with a regular partner diverged from satisfaction with overall sex life. Frequency of morning erections diverged from other aspects of erectile function, whereas erections with masturbation correlated better. Internal consistency was high overall. This tool is suitable for HIV-positive MSM and can be used in screening, research, and monitoring treatment response.
Llerena, Katiah; Wynn, Jonathan K; Hajcak, Greg; Green, Michael F; Horan, William P
2016-07-01
Accurately monitoring one's performance on daily life tasks, and integrating internal and external performance feedback are necessary for guiding productive behavior. Although internal feedback processing, as indexed by the error-related negativity (ERN), is consistently impaired in schizophrenia, initial findings suggest that external performance feedback processing, as indexed by the feedback negativity (FN), may actually be intact. The current study evaluated internal and external feedback processing task performance and test-retest reliability in schizophrenia. 92 schizophrenia outpatients and 63 healthy controls completed a flanker task (ERN) and a time estimation task (FN). Analyses examined the ΔERN and ΔFN defined as difference waves between correct/positive versus error/negative feedback conditions. A temporal principal component analysis was conducted to distinguish the ΔERN and ΔFN from overlapping neural responses. We also assessed test-retest reliability of ΔERN and ΔFN in patients over a 4-week interval. Patients showed reduced ΔERN accompanied by intact ΔFN. In patients, test-retest reliability for both ΔERN and ΔFN over a four-week period was fair to good. Individuals with schizophrenia show a pattern of impaired internal, but intact external, feedback processing. This pattern has implications for understanding the nature and neural correlates of impaired feedback processing in schizophrenia. Published by Elsevier B.V.
Detecting GNSS spoofing attacks using INS coupling
NASA Astrophysics Data System (ADS)
Tanil, Cagatay
Vulnerability of Global Navigation Satellite Systems (GNSS) users to signal spoofing is a critical threat to positioning integrity, especially in aviation applications, where the consequences are potentially catastrophic. In response, this research describes and evaluates a new approach to directly detect spoofing using integrated Inertial Navigation Systems (INS) and fault detection concepts based on integrity monitoring. The monitors developed here can be implemented into positioning systems using INS/GNSS integration via 1) tightly-coupled, 2) loosely-coupled, and 3) uncoupled schemes. New evaluation methods enable the statistical computation of integrity risk resulting from a worst-case spoofing attack - without needing to simulate an unmanageably large number of individual aircraft approaches. Integrity risk is an absolute measure of safety and a well-established metric in aircraft navigation. A novel closed-form solution to the worst-case time sequence of GNSS signals is derived to maximize the integrity risk for each monitor and used in the covariance analyses. This methodology tests the performance of the monitors against the most sophisticated spoofers, capable of tracking the aircraft position - for example, by means of remote tracking or onboard sensing. Another contribution is a comprehensive closed-loop model that encapsulates the vehicle and compensator (estimator and controller) dynamics. A sensitivity analysis uses this model to quantify the leveraging impact of the vehicle's dynamic responses (e.g., to wind gusts, or to autopilot's acceleration commands) on the monitor's detection capability. The performance of the monitors is evaluated for two safety-critical terminal area navigation applications: 1) autonomous shipboard landing and 2) Boeing 747 (B747) landing assisted with Ground Based Augmentation Systems (GBAS). It is demonstrated that for both systems, the monitors are capable of meeting the most stringent precision approach and landing integrity requirements of the International Civil Aviation Organization (ICAO). The statistical evaluation methods developed here can be used as a baseline procedure in the Federal Aviation Administration's (FAA) certification of spoof-free navigation systems. The final contribution is an investigation of INS sensor quality on detection performance. This determines the minimum sensor requirements to perform standalone GNSS positioning in general en route applications with guaranteed spoofing detection integrity.
Design and Laboratory Testing of a Prototype Linear Temperature Sensor
1982-07-01
computer, critical quantities such as the line sensor’s voltage, vertical position and, occasionally, a point sensor were also monitored in real time on a...REUT.............. ........... * 30 5.1 Linearity - Comparison With Thoy............... 31 5.2 Response Time ...from some initial time t 0 is more relevant to the measurement of internal waves (since the second term in 0 the above equation is usually small
NASA Astrophysics Data System (ADS)
Bertholet, Jenny; Toftegaard, Jakob; Hansen, Rune; Worm, Esben S.; Wan, Hanlin; Parikh, Parag J.; Weber, Britta; Høyer, Morten; Poulsen, Per R.
2018-03-01
The purpose of this study was to develop, validate and clinically demonstrate fully automatic tumour motion monitoring on a conventional linear accelerator by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK). COSMIK combines auto-segmentation of implanted fiducial markers in cone-beam computed tomography (CBCT) projections and intra-treatment kV images with simultaneous streaming of an external motion signal. A pre-treatment CBCT is acquired with simultaneous recording of the motion of an external marker block on the abdomen. The 3-dimensional (3D) marker motion during the CBCT is estimated from the auto-segmented positions in the projections and used to optimize an external correlation model (ECM) of internal motion as a function of external motion. During treatment, the ECM estimates the internal motion from the external motion at 20 Hz. KV images are acquired every 3 s, auto-segmented, and used to update the ECM for baseline shifts between internal and external motion. The COSMIK method was validated using Calypso-recorded internal tumour motion with simultaneous camera-recorded external motion for 15 liver stereotactic body radiotherapy (SBRT) patients. The validation included phantom experiments and simulations hereof for 12 fractions and further simulations for 42 fractions. The simulations compared the accuracy of COSMIK with ECM-based monitoring without model updates and with model updates based on stereoscopic imaging as well as continuous kilovoltage intrafraction monitoring (KIM) at 10 Hz without an external signal. Clinical real-time tumour motion monitoring with COSMIK was performed offline for 14 liver SBRT patients (41 fractions) and online for one patient (two fractions). The mean 3D root-mean-square error for the four monitoring methods was 1.61 mm (COSMIK), 2.31 mm (ECM without updates), 1.49 mm (ECM with stereoscopic updates) and 0.75 mm (KIM). COSMIK is the first combined kV/optical real-time motion monitoring method used clinically online on a conventional accelerator. COSMIK gives less imaging dose than KIM and is in addition applicable when the kV imager cannot be deployed such as during non-coplanar fields.
Multiplexed detection of anthrax-related toxin genes.
Moser, Michael J; Christensen, Deanna R; Norwood, David; Prudent, James R
2006-02-01
Simultaneous analysis of three targets in three colors on any real-time polymerase chain reaction (PCR) instrument would increase the flexibility of real-time PCR. For the detection of Bacillus strains that can cause inhalation anthrax-related illness, this ability would be valuable because two plasmids confer virulence, and internal positive controls are needed to monitor the testing in cases lacking target-specific signals. Using a real-time PCR platform called MultiCode-RTx, multiple assays were developed that specifically monitor the presence of Bacillus anthracis-specific virulence plasmid-associated genes. In particular for use on LightCycler-1, two triplex RTx systems demonstrated high sensitivity with limits of detection nearing single-copy levels for both plasmids. Specificity was established using a combination of Ct values and correct amplicon melting temperatures. All reactions were further verified by detection of an internal positive control. For these two triplex RTx assays, the analytical detection limit was one to nine plasmid copy equivalents, 100% analytical specificity with a 95% confidence interval (CI) of 9%, and 100% analytical sensitivity with a CI of 2%. Although further testing using clinical or environmental samples will be required to assess diagnostic sensitivity and specificity, the RTx platform achieves similar results to those of probe-based real-time systems.
Zhao, Lihong; Li, Ruiying; Liu, Aihua; Zhao, Shuping
2015-07-01
The objective of this study was to build and apply a duplex real time quantitative reverse transcription-polymerase chain reaction (RT-PCR) for rubella virus. Firstly, a 60-bp-long armored RV RNA was constructed in the laboratory. Secondly, a duplex real time RT-PCR assay was established. Thirdly, the 60-bp-long armored RV RNA was used as an internal positive control (IPC) for the duplex real time RT-PCR. And finally the duplex real time RT-PCR assay was applied to detect RV RNA in clinical specimens. The in-house assay has a high amplification efficiency (0.99), a high analytical sensitivity (200 copies/mL), and a good reproducibility. The diagnostic specificity and sensitivity of the in-house assay were both 100%, due to the monitoring of the armored RV RNA IPC. Therefore, the in-house duplex real time quantitative RT-PCR assay is a specific, sensitive, reproducible and accurate assay for quantitation of RV RNA in clinical specimens. And noncompetitive armored RV RNA IPC can monitor RT-PCR inhibition and prevent false-negative and inaccurate results in the real time detection system. Copyright © 2015 Elsevier B.V. All rights reserved.
Chan, Alvin Y; Kharrat, Sohayla; Lundeen, Kelly; Mnatsakanyan, Lilit; Sazgar, Mona; Sen-Gupta, Indranil; Lin, Jack J; Hsu, Frank P K; Vadera, Sumeet
2017-06-01
Lowering the length of stay (LOS) is thought to potentially decrease hospital costs and is a metric commonly used to manage capacity. Patients with epilepsy undergoing intracranial electrode monitoring may have longer LOS because the time to seizure is difficult to predict or control. This study investigates the effect of economic implications of increased LOS in patients undergoing invasive electrode monitoring for epilepsy. We retrospectively collected and analyzed patient data for 76 patients who underwent invasive monitoring with either subdural grid (SDG) implantation or stereoelectroencephalography (SEEG) over 2 years at our institution. Data points collected included invasive electrode type, LOS, profit margin, contribution margins, insurance type, and complication rates. LOS correlated positively with both profit and contribution margins, meaning that as LOS increased, both the profit and contribution margins rose, and there was a low rate of complications in this patient group. This relationship was seen across a variety of insurance providers. These data suggest that LOS may not be the best metric to assess invasive monitoring patients (i.e., SEEG or SDG), and increased LOS does not necessarily equate with lower or negative institutional financial gain. Further research into LOS should focus on specific specialties, as each may differ in terms of financial implications. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.
Varley, Matthew C; Di Salvo, Valter; Modonutti, Mattia; Gregson, Warren; Mendez-Villanueva, Alberto
2018-03-01
This study investigated the effects of successive matches on match-running in elite under-23 soccer players during an international tournament. Match-running data was collected using a semi-automated multi-camera tracking system during an international under-23 tournament from all participating outfield players. Players who played 100% of all group stage matches were included (3 matches separated by 72 h, n = 44). Differences in match-running performance between matches were identified using a generalised linear mixed model. There were no clear effects for total, walking, jogging, running, high-speed running and sprinting distance between matches 1 and 3 (effect size (ES); -0.32 to 0.05). Positional analysis found that sprint distance was largely maintained from matches 1 to 3 across all positions. Attackers had a moderate decrease in total, jogging and running distance between matches 1 and 3 (ES; -0.72 to -0.66). Classifying players as increasers or decreasers in match-running revealed that match-running changes are susceptible to individual differences. Sprint performance appears to be maintained over successive matches regardless of playing position. However, reductions in other match-running categories vary between positions. Changes in match-running over successive matches affect individuals differently; thus, players should be monitored on an individual basis.
UTC Dissemination to the Real-Time User: The Role of USNO
NASA Technical Reports Server (NTRS)
Miranian, Mihran
1996-01-01
Coordinated Universal Time (UTC) is available worldwide via the Global Positioning System (GPS). The UTC disseminated by GPS is referenced to the US Naval Observatory Master Clock UTC(USNO) which is regularly steered and maintained as close as possible to UTC Bureau International des Poids et Mesures (BIPM), the international time scale. This paper will describe the role of the USNO in monitoring the time disseminated by the GPS and the steps involved to ensure its accuracy to the user. The paper will also discuss the other sources of UTC(USNO) and the process by which UTC(USNO) is steered to UTC(BIPM).
Movement Demands of Elite U20 International Rugby Union Players
Drawer, Scott; Eager, Robin; Taylor, Neil; Cook, Christian
2016-01-01
The purpose of this study was to quantify movement demands of elite international age grade (U20) rugby union players during competitive tournament match play. Forty elite professional players from an U20 international performance squad were monitored using 10Hz global positioning systems (GPS) during 15 international tournament matches during the 2014/15 and 2015/16 seasons. Data on distances, velocities, accelerations, decelerations, high metabolic load (HML) distance and efforts, and number of sprints were derived. Data files from players who played over 60 min (n = 161) were separated firstly into Forwards and Backs, and more specifically into six positional groups; FR—Front Row (prop & hooker), SR—Second Row, BR—Back Row (Flankers & No.8), HB—Half Backs (scrum half & outside half), MF—Midfield (centres), B3 –Back Three (wings & full back) for match analysis. Analysis revealed significant differences between forwards and backs positions. Backs scored higher on all variables measured with the exception of number of moderate accelerations, decelerations (no difference). The centres covered the greatest total distance with the front row covering the least (6.51 ± 0.71 vs 4.97 ± 0.75 km, p < 0.001). The front row also covered the least high speed running (HSR) distance compared to the back three (211.6 ± 112.7 vs 728.4 ± 150.2 m, p < 0.001) who covered the most HSR distance, affirming that backs cover greater distances but forwards have greater contact loads. These findings highlight for the first time differences in the movement characteristics of elite age grade rugby union players specific to positional roles. PMID:27055230
Movement Demands of Elite U20 International Rugby Union Players.
Cunningham, Daniel; Shearer, David A; Drawer, Scott; Eager, Robin; Taylor, Neil; Cook, Christian; Kilduff, Liam P
2016-01-01
The purpose of this study was to quantify movement demands of elite international age grade (U20) rugby union players during competitive tournament match play. Forty elite professional players from an U20 international performance squad were monitored using 10 Hz global positioning systems (GPS) during 15 international tournament matches during the 2014/15 and 2015/16 seasons. Data on distances, velocities, accelerations, decelerations, high metabolic load (HML) distance and efforts, and number of sprints were derived. Data files from players who played over 60 min (n = 161) were separated firstly into Forwards and Backs, and more specifically into six positional groups; FR--Front Row (prop & hooker), SR--Second Row, BR--Back Row (Flankers & No.8), HB--Half Backs (scrum half & outside half), MF--Midfield (centres), B3--Back Three (wings & full back) for match analysis. Analysis revealed significant differences between forwards and backs positions. Backs scored higher on all variables measured with the exception of number of moderate accelerations, decelerations (no difference). The centres covered the greatest total distance with the front row covering the least (6.51 ± 0.71 vs 4.97 ± 0.75 km, p < 0.001). The front row also covered the least high speed running (HSR) distance compared to the back three (211.6 ± 112.7 vs 728.4 ± 150.2 m, p < 0.001) who covered the most HSR distance, affirming that backs cover greater distances but forwards have greater contact loads. These findings highlight for the first time differences in the movement characteristics of elite age grade rugby union players specific to positional roles.
Vandenbulcke, F; Nouel, D; Vincent, J P; Mazella, J; Beaudet, A
2000-09-01
The neuropeptide neurotensin (NT) is known to be internalized in a receptor-mediated fashion into its target cells. To gain insight into the mechanisms underlying this process, we monitored in parallel the migration of the NT1 neurotensin receptor subtype and a fluorescent analog of NT (fluo-NT) in COS-7 cells transfected with a tagged NT1 construct. Fluo-NT internalization was prevented by hypertonic sucrose, potassium depletion and cytosol acidification, demonstrating that it proceeded via clathrin-coated pits. Within 0-30 minutes, fluo-NT accumulated together with its receptor in Acridine Orange-positive, acidic organelles. These organelles concentrated transferrin and immunostained positively for rab 5A, therefore they were early endosomes. After 30-45 minutes, the ligand and its receptor no longer colocalized. Fluo-NT was first found in rab 7-positive late endosomes and later in a nonacidic juxtanuclear compartment identified as the Trans-Golgi Network (TGN) by virtue of its staining for syntaxin 6. This juxtanuclear compartment also stained positively for rab 7 and for the TGN/pericentriolar recycling endosome marker rab 11, suggesting that the ligand could have been recruited to the TGN from either late or recycling endosomes. By that time, internalized receptors were detected in Lamp-1-immunoreactive lysosomes. These results demonstrate that neurotensin/NT1 receptor complexes follow a recycling cycle that is unique among the G protein-coupled receptors studied to date, and provide the first evidence for the targeting of a nonendogenous protein from endosomes to the TGN.
Necessity of Internal Monitoring for Nuclear Medicine Staff in a Large Specialized Chinese Hospital
Wang, Hong-Bo; Zhang, Qing-Zhao; Zhang, Zhen; Hou, Chang-Song; Li, Wen-Liang; Yang, Hui; Sun, Quan-Fu
2016-01-01
This work intends to quantify the risk of internal contaminations in the nuclear medicine staff of one hospital in Henan province, China. For this purpose, the criteria proposed by the International Atomic Energy Agency (IAEA) to determine whether it is necessary to conduct internal individual monitoring was applied to all of the 18 nuclear medicine staff members who handled radionuclides. The activity of different radionuclides used during a whole calendar year and the protection measures adopted were collected for each staff member, and the decision as to whether nuclear medicine staff in the hospital should be subjected to internal monitoring was made on the basis of the criteria proposed by IAEA. It is concluded that for all 18 members of the nuclear medicine staff in the hospital, internal monitoring is required. Internal exposure received by nuclear medicine staff should not be ignored, and it is necessary to implement internal monitoring for nuclear medicine staff routinely. PMID:27077874
Necessity of Internal Monitoring for Nuclear Medicine Staff in a Large Specialized Chinese Hospital.
Wang, Hong-Bo; Zhang, Qing-Zhao; Zhang, Zhen; Hou, Chang-Song; Li, Wen-Liang; Yang, Hui; Sun, Quan-Fu
2016-04-12
This work intends to quantify the risk of internal contaminations in the nuclear medicine staff of one hospital in Henan province, China. For this purpose, the criteria proposed by the International Atomic Energy Agency (IAEA) to determine whether it is necessary to conduct internal individual monitoring was applied to all of the 18 nuclear medicine staff members who handled radionuclides. The activity of different radionuclides used during a whole calendar year and the protection measures adopted were collected for each staff member, and the decision as to whether nuclear medicine staff in the hospital should be subjected to internal monitoring was made on the basis of the criteria proposed by IAEA. It is concluded that for all 18 members of the nuclear medicine staff in the hospital, internal monitoring is required. Internal exposure received by nuclear medicine staff should not be ignored, and it is necessary to implement internal monitoring for nuclear medicine staff routinely.
5 CFR 575.212 - Internal monitoring requirements and revocation or suspension of authority.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Internal monitoring requirements and... MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, RELOCATION, AND RETENTION INCENTIVES; SUPERVISORY DIFFERENTIALS; AND EXTENDED ASSIGNMENT INCENTIVES Relocation Incentives § 575.212 Internal monitoring...
5 CFR 575.312 - Internal monitoring requirements and revocation or suspension of authority.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Internal monitoring requirements and... MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, RELOCATION, AND RETENTION INCENTIVES; SUPERVISORY DIFFERENTIALS; AND EXTENDED ASSIGNMENT INCENTIVES Retention Incentives § 575.312 Internal monitoring...
Environmental, political, and economic determinants of water quality monitoring in Europe
NASA Astrophysics Data System (ADS)
Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna
2010-11-01
Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.
Diabetes Canada Position Statement for People with Types 1 and 2 Diabetes Who Fast During Ramadan.
Bajaj, Harpreet Singh; Abouhassan, Tyceer; Ahsan, Muhammad Rauf; Arnaout, Amel; Hassanein, Mohamed; Houlden, Robyn L; Khan, Tayyab; Khandwala, Hasnain; Verma, Subodh
2018-04-27
Fasting from dawn to dusk during Ramadan, including abstaining from water and food, is 1 of the pillars of Islam and is observed by the majority of Muslims. Most research concerning diabetes and fasting during Ramadan originates from Middle Eastern or South Asian countries; however, differences exist in hours of work and fasting, pharmacotherapy and blood glucose monitoring between these countries and Canada. An expert forum of 7 Canadian experts and 1 international expert collaborated to develop Canadian guidelines using the same evidence-based principles, with the exception of an independent methods review used for the Diabetes Canada clinical practice guidelines. Diabetes Canada scientific leadership and Canadian health-care providers performed independent external reviews. Religious leaders endorsed the position statement and provided letters of support. An informed patient participated in the position-statement development. Each recommendation was approved with 100% consensus of the expert forum. Recommendations for risk stratification, education, pharmacotherapy and blood glucose monitoring for adults with type 1 and type 2 diabetes who intend to fast during Ramadan have been developed. This is the first Canadian position statement on the topic of Ramadan fasting and diabetes. It was developed by an expert faculty and endorsed by Diabetes Canada, and provides guidance about pharmacotherapy and glucose monitoring for health-care providers so that they can assist Canadian Muslims living with diabetes to observe fasting during Ramadan safely. Copyright © 2018. Published by Elsevier Inc.
Donato, D B; Madden-Hallett, D M; Smith, G B; Gursansky, W
2017-06-01
Exposed cyanide-bearing solutions associated with gold and silver recovery processes in the mining industry pose a risk to wildlife that interact with these solutions. This has been documented with cyanide-bearing tailings storage facilities, however risks associated with heap leach facilities are poorly documented, monitored and audited. Gold and silver leaching heap leach facilities use cyanide, pH-stabilised, at concentrations deemed toxic to wildlife. Their design and management are known to result in exposed cyanide-bearing solutions that are accessible to and present a risk to wildlife. Monitoring of the presence of exposed solutions, wildlife interaction, interpretation of risks and associated wildlife deaths are poorly documented. This paper provides a list of critical monitoring criteria and attempts to predict wildlife guilds most at risk. Understanding the significance of risks to wildlife from exposed cyanide solutions is complex, involving seasonality, relative position of ponding, temporal nature of ponding, solution palatability, environmental conditions, in situ wildlife species inventory and provision of alternative drinking sources for wildlife. Although a number of heap leach operations are certified as complaint with the International Cyanide Management Code (Cyanide Code), these criteria are not considered by auditors nor has systematic monitoring regime data been published. Without systematic monitoring and further knowledge, wildlife deaths on heap leach facilities are likely to remain largely unrecorded. This has ramifications for those operations certified as compliance with the Cyanide Code. Copyright © 2017 Elsevier Inc. All rights reserved.
Coughlan, Garrett F; Green, Brian S; Pook, Paul T; Toolan, Eoin; O'Connor, Sean P
2011-08-01
Descriptive. To evaluate the physical demands of an international Rugby Union-level game using a global positioning system (GPS). Elite Rugby Union teams currently employ the latest technology to monitor and evaluate physical demands of training and games on their players. GPS data from 2 players, a back and a forward, were collected during an international Rugby Union game. Locomotion speed, total body load, and body load sustained in tackles and scrums were analyzed. Players completed an average distance of 6715 m and spent the major portion of the game standing or walking, interspersed with medium- and high-intensity running activities. The back performed a higher number of high-intensity sprints and reached a greater maximal speed. Body load data revealed that high levels of gravitational force are sustained in tackling and scrum tasks. The current study provides a detailed GPS analysis of the physical demands of international Rugby Union players. These data, when combined with game video footage, may assist sports medicine professionals in understanding the demands of the game and mechanism of injury, as well as improving injury rehabilitation.
50 CFR 300.37 - Radio monitoring.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 50 Wildlife and Fisheries 11 2013-10-01 2013-10-01 false Radio monitoring. 300.37 Section 300.37 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.37 Radio monitoring. The international distress frequency, 2.182 mHz...
50 CFR 300.37 - Radio monitoring.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 11 2012-10-01 2012-10-01 false Radio monitoring. 300.37 Section 300.37 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.37 Radio monitoring. The international distress frequency, 2.182 mHz...
50 CFR 300.37 - Radio monitoring.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Radio monitoring. 300.37 Section 300.37 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.37 Radio monitoring. The international distress frequency, 2.182 mHz...
50 CFR 300.37 - Radio monitoring.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 11 2014-10-01 2014-10-01 false Radio monitoring. 300.37 Section 300.37 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.37 Radio monitoring. The international distress frequency, 2.182 mHz...
50 CFR 300.37 - Radio monitoring.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Radio monitoring. 300.37 Section 300.37 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.37 Radio monitoring. The international distress frequency, 2.182 mHz...
49 CFR 192.477 - Internal corrosion control: Monitoring.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Internal corrosion control: Monitoring. 192.477... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.477 Internal corrosion control: Monitoring. If corrosive gas is being transported, coupons...
49 CFR 192.477 - Internal corrosion control: Monitoring.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Monitoring. 192.477... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.477 Internal corrosion control: Monitoring. If corrosive gas is being transported, coupons...
Evaluation of the WavTrac Expeditionary Mobility Matting System
2017-04-01
pavement applications. Designation D6951. West Conshohocken, PA: ASTM International. www.astm.org. Rushing, T. W., and J. F. Rowland. 2012. Comparison of...respective owners. The findings of this report are not to be construed as an official Department of the Army position unless so designated by other...The technical monitor was Jeb S. Tingle. The work was performed by the Airfields and Pavements Branch (APB) of the Engineering Systems and Materials
Monitoring Species of Concern Using Noninvasive Genetic Sampling and Capture-Recapture Methods
2016-06-01
contents be construed as reflecting the official policy or position of the Department of Defense. Reference herein to any specific commercial product...Reserve in Mexico, and is home to more than 400 plant species and over 300 wildlife species. Construction of a border fence along the international...pronghorn mortality, a semi- captive breeding pen was constructed to facilitate pronghorn recovery (Otte 2006). The one- square mile facility is double
Wireless powering and data telemetry for biomedical implants.
Young, Darrin J
2009-01-01
Wireless powering and data telemetry techniques for two biomedical implant studies based on (1) wireless in vivo EMG sensor for intelligent prosthetic control and (2) adaptively RF powered implantable bio-sensing microsystem for real-time genetically engineered mice monitoring are presented. Inductive-coupling-based RF powering and passive data telemetry is effective for wireless in vivo EMG sensing, where the internal and external RF coils are positioned with a small separation distance and fixed orientation. Adaptively controlled RF powering and active data transmission are critical for mobile implant application such as real-time physiological monitoring of untethered laboratory animals. Animal implant studies have been successfully completed to demonstrate the wireless and batteryless in vivo sensing capabilities.
Verbal Self-Monitoring in the Second Language
ERIC Educational Resources Information Center
Broos, Wouter P. J.; Duyck, Wouter; Hartsuiker, Robert J.
2016-01-01
Speakers monitor their own speech for errors. To do so, they may rely on perception of their own speech (external monitoring) but also on an internal speech representation (internal monitoring). While there are detailed accounts of monitoring in first language (L1) processing, it is not clear if and how monitoring is different in a second language…
Njelesani, Janet; Dacombe, Russell; Palmer, Tanith; Smith, Helen; Koudou, Benjamin; Bockarie, Moses; Bates, Imelda
2014-01-01
Background The lack of capacity in laboratory systems is a major barrier to achieving the aims of the London Declaration (2012) on neglected tropical diseases (NTDs). To counter this, capacity strengthening initiatives have been carried out in NTD laboratories worldwide. Many of these initiatives focus on individuals' skills or institutional processes and structures ignoring the crucial interactions between the laboratory and the wider national and international context. Furthermore, rigorous methods to assess these initiatives once they have been implemented are scarce. To address these gaps we developed a set of assessment and monitoring tools that can be used to determine the capacities required and achieved by laboratory systems at the individual, organizational, and national/international levels to support the control of NTDs. Methodology and principal findings We developed a set of qualitative and quantitative assessment and monitoring tools based on published evidence on optimal laboratory capacity. We implemented the tools with laboratory managers in Ghana, Malawi, Kenya, and Sri Lanka. Using the tools enabled us to identify strengths and gaps in the laboratory systems from the following perspectives: laboratory quality benchmarked against ISO 15189 standards, the potential for the laboratories to provide support to national and regional NTD control programmes, and the laboratory's position within relevant national and international networks and collaborations. Conclusion We have developed a set of mixed methods assessment and monitoring tools based on evidence derived from the components needed to strengthen the capacity of laboratory systems to control NTDs. Our tools help to systematically assess and monitor individual, organizational, and wider system level capacity of laboratory systems for NTD control and can be applied in different country contexts. PMID:24603407
The Brave New World of Real-time GPS for Hazards Mitigation
NASA Astrophysics Data System (ADS)
Melbourne, T. I.; Szeliga, W. M.; Santillan, V. M.; Scrivner, C. W.
2015-12-01
Over 600 continuously-operating, real-time telemetered GPS receivers operate throughout California, Oregon, Washington and Alaska. These receivers straddle active crustal faults, volcanoes and landslides, the magnitude-9 Cascadia and northeastern Alaskan subduction zones and their attendant tsunamigenic regions along the Pacific coast. Around the circum-Pacific, there are hundreds more and the number is growing steadily as real-time networks proliferate. Despite offering the potential for sub-cm positioning accuracy in real-time useful for a broad array of hazards mitigation, these GPS stations are only now being incorporated into routine seismic, tsunami, volcanic, land-slide, space-weather, or meterologic monitoring. We will discuss NASA's READI (Real-time Earthquake Analysis for DIsasters) initiative. This effort is focussed on developing all aspects of real-time GPS for hazards mitigation, from establishing international data-sharing agreements to improving basic positioning algorithms. READI's long-term goal is to expand real-time GPS monitoring throughout the circum-Pacific as overseas data become freely available, so that it may be adopted by NOAA, USGS and other operational agencies responsible for natural hazards monitoring. Currently ~100 stations are being jointly processed by CWU and Scripps Inst. of Oceanography for algorithm comparison and downstream merging purposes. The resultant solution streams include point-position estimates in a global reference frame every second with centimeter accuracy, ionospheric total electron content and tropospheric zenith water content. These solutions are freely available to third-party agencies over several streaming protocols to enable their incorporation and use in hazards monitoring. This number will ramp up to ~400 stations over the next year. We will also discuss technical efforts underway to develop a variety of downstream applications of the real-time position streams, including the ability to broadcast solutions to thousands of users in real time, earthquake finite-fault and tsunami excitation estimations, and several user interfaces, both stand-alone client and browser-based, that allow interaction with both real-time position streams and their derived products.
Study of nuclear medicine practices in Portugal from an internal dosimetry perspective.
Bento, J; Teles, P; Neves, M; Santos, A I; Cardoso, G; Barreto, A; Alves, F; Guerreiro, C; Rodrigues, A; Santos, J A M; Capelo, C; Parafita, R; Martins, B
2012-05-01
Nuclear medicine practices involve the handling of a wide range of pharmaceuticals labelled with different radionuclides, for diagnostic and therapeutic purposes. This work intends to evaluate the potential risks of internal contamination of nuclear medicine staff in several Portuguese nuclear medicine services and to conclude about the requirement of a routine internal monitoring. A methodology proposed by the International Atomic Energy Agency (IAEA), providing a set of criteria to determine the need, or not, for an internal monitoring programme, was applied. The evaluation of the risk of internal contaminations in a given set of working conditions is based on the type and amount of radionuclides being handled, as well as the safety conditions with which they are manipulated. The application of the IAEA criteria showed that 73.1% of all the workers included in this study should be integrated in a routine monitoring programme for internal contaminations; more specifically, 100% of workers performing radioimmunoassay techniques should be monitored. This study suggests that a routine monitoring programme for internal exposures should be implemented in Portugal for most nuclear medicine workers.
Competitor internal standards for quantitative detection of mycoplasma DNA.
Sidhu, M K; Rashidbaigi, A; Testa, D; Liao, M J
1995-05-01
Homologous internal controls were used as competitor DNA in the polymerase chain reaction for the quantitative detection of mycoplasma DNA. PCR primer sets were designed on the basis of the most conserved nucleotide sequences of the 16S rRNA gene of mycoplasma species. Amplification of this gene was examined in five different mycoplasma species: Mycoplasma orale, M. hyorhinus, M. synoviae, M. gallisepticum and M. pneumoniae. To evaluate the primers, a number of different cell lines were assayed for the detection of mycoplasma infections. All positive cell lines showed a distinct product on agarose gels while uninfected cells showed no DNA amplification. Neither bacterial nor eukaryotic DNA produced any cross-reaction with the primers used, thus confirming their specificity. Internal control DNA to be used for quantitation was constructed by modifying the sizes of the wild-type amplified products and cloning them in plasmid vectors. These controls used the same primer binding sites as the wild-type and the amplified products were differentiated by a size difference. The detection limits for all the mycoplasma species by competitive quantitative PCR were estimated to range from 4 to 60 genome copies per assay as determined by ethidium bromide-stained agarose gels. These internal standards also serve as positive controls in PCR-based detection of mycoplasma DNA, and therefore accidental contamination of test samples with wild-type positive controls can be eliminated. The quantitative PCR method developed will be useful in monitoring the progression and significance of mycoplasma in the disease process.
Peyraud, Armelle; Poumarat, François; Tardy, Florence; Manso-Silván, Lucía; Hamroev, Karomatullo; Tilloev, Tillo; Amirbekov, Mullojon; Tounkara, Karim; Bodjo, Charles; Wesonga, Hezron; Nkando, Isabel Gacheri; Jenberie, Shiferaw; Yami, Martha; Cardinale, Eric; Meenowa, Deodass; Jaumally, Mahmad Reshad; Yaqub, Tahir; Shabbir, Muhammad Zubair; Mukhtar, Nadia; Halimi, Mohibullah; Ziay, Ghulam Mohammad; Schauwers, Willy; Noori, Hafizullah; Rajabi, Ali Madad; Ostrowski, Stéphane; Thiaucourt, François
2014-02-24
Few serological tests are available for detecting antibodies against Mycoplasma capricolum subsp. capripneumoniae, the causal agent of contagious caprine pleuropneumonia (CCPP). The complement fixation test, the test prescribed for international trade purposes, uses a crude antigen that cross-reacts with all the other mycoplasma species of the "mycoides cluster" frequently infecting goat herds. The lack of a more specific test has been a real obstacle to the evaluation of the prevalence and economic impact of CCPP worldwide. A new competitive ELISA kit for CCPP, based on a previous blocking ELISA, was formatted at CIRAD and used to evaluate the prevalence of CCPP in some regions of Kenya, Ethiopia, Mauritius, Tajikistan and Pakistan in an international collaborative study. The strict specificity of the test was confirmed in CCPP-free goat herds exposed to other mycoplasma species of the "mycoides cluster". Prevalence studies were performed across the enzootic range of the disease in Africa and Asia. Seroprevalence was estimated at 14.6% in the Afar region of Ethiopia, whereas all the herds presented for CCPP vaccination in Kenya tested positive (individual seroprevalence varied from 6 to 90% within each herd). In Mauritius, where CCPP emerged in 2009, nine of 62 herds tested positive. In Central Asia, where the disease was confirmed only recently, no positive animals were detected in the Wakhan District of Afghanistan or across the border in neighboring areas of Tajikistan, whereas seroprevalence varied between 2.7% and 44.2% in the other districts investigated and in northern Pakistan. The test was also used to monitor seroconversion in vaccinated animals. This newly formatted CCPP cELISA kit has retained the high specificity of the original kit. It can therefore be used to evaluate the prevalence of CCPP in countries or regions without vaccination programs. It could also be used to monitor the efficacy of vaccination campaigns as high-quality vaccines induce high rates of seroconversion.
2014-01-01
Background Few serological tests are available for detecting antibodies against Mycoplasma capricolum subsp. capripneumoniae, the causal agent of contagious caprine pleuropneumonia (CCPP). The complement fixation test, the test prescribed for international trade purposes, uses a crude antigen that cross-reacts with all the other mycoplasma species of the “mycoides cluster” frequently infecting goat herds. The lack of a more specific test has been a real obstacle to the evaluation of the prevalence and economic impact of CCPP worldwide. A new competitive ELISA kit for CCPP, based on a previous blocking ELISA, was formatted at CIRAD and used to evaluate the prevalence of CCPP in some regions of Kenya, Ethiopia, Mauritius, Tajikistan and Pakistan in an international collaborative study. Results The strict specificity of the test was confirmed in CCPP-free goat herds exposed to other mycoplasma species of the “mycoides cluster”. Prevalence studies were performed across the enzootic range of the disease in Africa and Asia. Seroprevalence was estimated at 14.6% in the Afar region of Ethiopia, whereas all the herds presented for CCPP vaccination in Kenya tested positive (individual seroprevalence varied from 6 to 90% within each herd). In Mauritius, where CCPP emerged in 2009, nine of 62 herds tested positive. In Central Asia, where the disease was confirmed only recently, no positive animals were detected in the Wakhan District of Afghanistan or across the border in neighboring areas of Tajikistan, whereas seroprevalence varied between 2.7% and 44.2% in the other districts investigated and in northern Pakistan. The test was also used to monitor seroconversion in vaccinated animals. Conclusions This newly formatted CCPP cELISA kit has retained the high specificity of the original kit. It can therefore be used to evaluate the prevalence of CCPP in countries or regions without vaccination programs. It could also be used to monitor the efficacy of vaccination campaigns as high-quality vaccines induce high rates of seroconversion. PMID:24565080
Performance of a reentrant cavity beam position monitor
NASA Astrophysics Data System (ADS)
Simon, Claire; Luong, Michel; Chel, Stéphane; Napoly, Olivier; Novo, Jorge; Roudier, Dominique; Rouvière, Nelly; Baboi, Nicoleta; Mildner, Nils; Nölle, Dirk
2008-08-01
The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs). In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryomodule, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10μm and has the possibility to perform bunch to bunch measurements for the x-ray free electron laser (X-FEL) and the International Linear Collider (ILC). Its other features are a small size of the rf cavity, a large aperture (78 mm), and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH), at Deutsches Elektronen-Synchrotron (DESY) and demonstrated its operation at cryogenic temperature inside a cryomodule. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4μm over a dynamic range ±5mm in single bunch.
Dillon, Paul; Smith, Susan M; Gallagher, Paul; Cousins, Gráinne
2018-06-13
Community pharmacy is an ideal setting to monitor medication adherence, however, barriers to pharmacist-led interventions exist. Preparing future pharmacists for enhanced roles may overcome such barriers. Our objective was to identify medication monitoring attitudes and contextual factors that influence adherence monitoring by pharmacy interns to inform educational activities on medication adherence. An online factorial survey of all pharmacy interns (N = 123) in the Republic of Ireland, completing advanced community pharmacy experiential learning in May 2016 was undertaken to evaluate attitudes to medication monitoring and to identify respondent characteristics and contextual factors which influence adherence monitoring of older hypertensive adults during repeat dispensing. The medication monitoring attitude measure (MMAM) was used to evaluate interns' attitudes, and factorial vignette analysis was performed to identify factors influencing behavioural intention to offer adherence advice. There were 121 completed online surveys. Half of interns reported they felt uncomfortable and confrontational discussing adherence with patients. In factorial vignette analysis, higher medication monitoring attitudes resulted in higher likelihood to offer adherence advice; experiential-learning characteristics such as pharmacy ownership-type (nonchain store) and contextual factors including patients being treated for longer and time-pressures had a significant negative influence on pharmacy interns' likelihood to offer adherence advice. Medication monitoring attitudes and contextual factors influenced responses to offer adherence advice in hypothetical scenarios. Ensuring pharmacy students are educated on patterns of adherence and appropriate skills to address nonadherence, and engage in structured programmes to facilitate patient interactions during experiential learning, may improve medication monitoring attitudes and adherence monitoring. © 2018 Royal Pharmaceutical Society.
Schooley, Janine; Morales, Linda
2007-01-01
The "traditional" use of the Positive Deviance approach to behavior change involves studying children who thrive despite adversity, identifying uncommon model behaviors among Positive Deviant families, and then designing and implementing an intervention to replicate these behaviors among mothers of malnourished children. This article presents the results of a literature review designed to gather information on the role of the Positive Deviance/Hearth methodology in social and behavior change. Examples of how the methodology has been applied beyond infant and child malnutrition to address other health areas, such as improving pregnancy outcomes, are explored. An analysis of Positive Deviance programming being carried out by Project Concern International in Guatemala and Indonesia is conducted. The role of cultural context in the design and implementation of Positive Deviance/Hearth, as well as the role of Positive Deviance in affecting social and behavior change, require further exploration. The issues related to cultural context and the challenges for monitoring and evaluation of program outcomes are presented.
Space Environment Effects on Materials at Different Positions and Operational Periods of ISS
NASA Astrophysics Data System (ADS)
Kimoto, Yugo; Ichikawa, Shoichi; Miyazaki, Eiji; Matsumoto, Koji; Ishizawa, Junichiro; Shimamura, Hiroyuki; Yamanaka, Riyo; Suzuki, Mineo
2009-01-01
A space materials exposure experiment was condcuted on the exterior of the Russian Service Module (SM) of the International Space Station (ISS) using the Micro-Particles Capturer and Space Environment Exposure Device (MPAC&SEED) of the Japan Aerospace Exploration Agency (JAXA). Results reveal artificial environment effects such as sample contamination, attitude change effects on AO fluence, and shading effects of UV on ISS. The sample contamination was coming from ISS components. The particles attributed to micrometeoroids and/or debris captured by MPAC might originate from the ISS solar array. Another MPAC&SEED will be aboard the Exposure Facility of the Japanese Experiment Module, KIBO Exposure Facility (EF) on ISS. The JEM/MPAC&SEED is attached to the Space Environment Data Acquisition Equipment-Attached Payload (SEDA-AP) and is exposed to space. Actually, SEDA-AP is a payload on EF to be launched by Space Shuttle flight 2J/A. In fact, SEDA-AP has space environment monitors such as a high-energy particle monitor, atomic oxygen monitor, and plasma monitor to measure in-situ natural space environment data during JEM/MPAC&SEED exposure. Some exposure samples for JEM/MPAC&SEED are identical to SM/MPAC&SEED samples. Consequently, effects on identical materials at different positions and operation periods of ISS will be evaluated. This report summarizes results from space environment monitoring samples for atomic oxygen analysis on SM/MPAC&SEED, along with experimental plans for JEM/MPAC&SEED.
International GPS Service for Geodynamics
NASA Technical Reports Server (NTRS)
Zumberge, J. F. (Editor); Urban, M. P. (Editor); Liu, R. (Editor); Neilan, R. E. (Editor)
1996-01-01
This 1995 annual report of the IGS International GPS (Global Positioning System) Service for Geodynamics - describes the second operational year of the service. It provides the many IGS contributing agencies and the rapidly growing user community with essential information on current organizational and technical matters promoting the IGS standards and products (including organizational framework, data processing strategies, and statistics showing the remarkable expansion of the GPS monitoring network, the improvement of IGS performance, and product quality). It also introduces important practical concepts for network densification by integration of regional stations and the combination of station coordinate solutions. There are groups of articles describing general aspects of the IGS, the Associate Analysis Centers (AACs), Data Centers, and IGS stations.
NASA Astrophysics Data System (ADS)
Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-01-01
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r2. Only three of the ten patients showed correlation higher than r2 = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r2 = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.
Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-01-21
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r(2). Only three of the ten patients showed correlation higher than r(2) = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r(2) = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.
Clinical pharmacology in Russia-historical development and current state.
Zagorodnikova Goryachkina, Ksenia; Burbello, Aleksandra; Sychev, Dmitry; Frolov, Maxim; Kukes, Vladimir; Petrov, Vladimir
2015-02-01
Clinical pharmacology in Russia has long history and is currently active, but rather unrecognized internationally. It is governmentally approved as a teaching/scientific specialty since 1983 and as a medical specialty since 1997. Courses of clinical pharmacology are included in the undergraduate curricula in the 5th and/or 6th year of education at all medical schools in the Russian Federation. Postgraduate education includes initial specialization in internal medicine with further residency in clinical pharmacology. Governmental legislation recommends that every healthcare institution has either a department or a single position of clinical pharmacologist. Major routine duties include information about and monitoring of medication use, consultations in difficult clinical situations, pharmacogenetic counseling, therapeutic drug monitoring, pharmacovigilance, and participation in drug and therapeutics (formulary) committees. There are official experts in clinical pharmacology in Russia responsible for coordinating relevant legislative issues. The chief expert clinical pharmacologist represents the discipline directly at the Ministry of Health. Research in clinical pharmacology in Russia is extensive and variable, but only some of it is published internationally. Russia is a participant of international societies of clinical pharmacology and therapeutics and collaboration is actively ongoing. There are still certain problems related to the development of the discipline in Russia-some healthcare institutions do not see the need for clinical pharmacology. However, the number of clinical pharmacologists in Russia is increasing as well as their role in physicians' education, national healthcare, and research.
Martins, Filipa; Soares, Sandra C; Bem-Haja, Pedro; Roque, Carolina; Madeira, Nuno
2015-10-14
The aim of this study was to develop and validate a Portuguese version of The Subjective Experiences of Psychosis Scale (SEPS) for use in Portuguese-speaking populations in order to provide a self-report instrument to assess and monitor dimensions of psychotic experiences, translating patient's perspective and experience in terms of recovery from psychosis. The sample consisted of 30 participants with psychotic disorders who had recently experienced delusions or hallucinations. The SEPS was completed along with other observer-based assessments and self-report questionnaires, such as the Brief Psychiatric Rating Scale, the Insight and Treatment Attitudes Questionnaire and the Function Assessment Short Test. Two main factors representing the positive and negative components of each subscale were identified. We obtained good internal consistency and test-retest reliability for the positive and negative components of all subscales. The subscales of SEPS correlated with observer-based assessments and self-report questionnaires. The Portuguese version of the SEPS is a useful tool in the assessment and monitoring of psychotic symptoms.
Young, Andrew L.
2015-01-01
Internal derangements of the temporomandibular joint are conditions in which the articular disc has become displaced from its original position the condylar head. Relevant anatomic structures and their functional relationships are briefly discussed. The displacement of the disc can result in numerous presentations, with the most common being disc displacement with reduction (with or without intermittent locking), and disc displacement without reduction (with or without limited opening). These are described in this article according to the standardized Diagnostic Criteria for Temporomandibular Disorders, as well as the less common posterior disc displacement. Appropriate management usually ranges from patient education and monitoring to splints, physical therapy, and medications. In rare and select cases, surgery may be necessary. However, in for the majority of internal derangements, the prognosis is good, particularly with conservative care. PMID:26929478
Young, Andrew L
2015-01-01
Internal derangements of the temporomandibular joint are conditions in which the articular disc has become displaced from its original position the condylar head. Relevant anatomic structures and their functional relationships are briefly discussed. The displacement of the disc can result in numerous presentations, with the most common being disc displacement with reduction (with or without intermittent locking), and disc displacement without reduction (with or without limited opening). These are described in this article according to the standardized Diagnostic Criteria for Temporomandibular Disorders, as well as the less common posterior disc displacement. Appropriate management usually ranges from patient education and monitoring to splints, physical therapy, and medications. In rare and select cases, surgery may be necessary. However, in for the majority of internal derangements, the prognosis is good, particularly with conservative care.
Kochanska, Grazyna; Boldt, Lea J.; Kim, Sanghag; Yoon, Jeung Eun; Philibert, Robert A.
2014-01-01
We followed 100 community families from toddler age to preadolescence. Each mother- and father-child dyad was observed at 25, 38, 52, 67, and 80 months (10 hours per child) to assess positive and power-assertive parenting. At age 10 (N=82), we obtained parent- and child-reported outcome measures of children’s acceptance of parental socialization: cooperation with parental monitoring, negative attitude toward substance use, internalization of adult values, and callous-unemotional (CU) tendencies. Children who carried a short 5-HTTLPR allele and were highly anger prone, based on anger observed in laboratory from 25 to 80 months, were classified as high in biobehavioral risk. The remaining children were classified as low in biobehavioral risk. Biobehavioral risk moderated links between parenting history and outcomes. For low-risk children, parenting measures were unrelated to outcomes. For children high in biobehavioral risk, variations in positive parenting predicted cooperation with monitoring and negative attitude toward substance use, and variations in power-assertive parenting predicted internalization of adult values and CU tendencies. Suboptimal parenting combined with high biobehavioral risk resulted in the poorest outcomes. The effect for attitude toward substance use supported differential susceptibility: Children high in biobehavioral risk who received optimal parenting had a more adaptive outcome than their low-risk peers. The remaining effects were consistent with diathesis-stress. PMID:25154427
D'Havé, Helga; Scheirs, Jan; Mubiana, Valentine Kayawe; Verhagen, Ron; Blust, Ronny; De Coen, Wim
2006-08-01
The role of hair and spines of the European hedgehog as non-destructive monitoring tools of metal (Ag, Al, Cd, Co, Cr, Cu, Fe, Ni, Pb, Zn) and As pollution in terrestrial ecosystems was investigated. Our results showed that mean pollution levels of a random sample of hedgehogs in Flanders are low to moderate. Yet, individual hedgehogs may be at risk for metal toxicity. Tissue distribution analyses (hair, spines, liver, kidney, muscle and fat tissue) indicated that metals and As may reach considerable concentrations in external tissues, such as hair and spines. Positive relationships were observed between concentrations in hair and those in liver, kidney and muscle for Al, Co, Cr, Cu, and Pb (0.43 < r < 0.85). Spine concentrations were positively related to liver, kidney and muscle concentrations for Cd, Co, Cr, Cu and Pb (0.37 < r < 0.62). Hair Ag, As, Fe and Zn and spine Ag, Al, As and Fe were related to metal concentrations in one or two of the investigated internal tissues (0.31 < r < 0.45). The regression models presented here may be used to predict metal and As concentrations in internal tissues of hedgehogs when concentrations in hair or spines are available. The present study demonstrated the possibility of using hair and spines for non-destructive monitoring of metal and As pollution in hedgehogs.
Cardiovascular Assessment of Falls in Older People
Tan, Maw Pin; Kenny, Rose Anne
2006-01-01
Falls in older people can be caused by underlying cardiovascular disorders, either because of balance instability in persons with background gait and balance disorders, or because of amnesia for loss of consciousness during unwitnessed syncope. Pertinent investigations include a detailed history, 12-lead electrocardiography, lying and standing blood pressure, carotid sinus massage (CSM), head-up tilt, cardiac electrophysiological tests, and ambulatory blood pressure and heart rate monitoring, which includes external and internal cardiac monitoring. The presence of structural heart disease predicts an underlying cardiac cause. Conversely, the absence of either indicates that neurally mediated etiology is likely. CSM and tilt-table testing should be considered in patients with unexplained and recurrent falls. Holter monitoring over 24 hours has a low diagnostic yield. Early use of an implantable loop recorder may be more cost-effective. A dedicated investigation unit increases the likelihood of achieving positive diagnoses and significantly reduces hospital stay and health expenditure. PMID:18047258
Monitoring the health-related labelling of foods and non-alcoholic beverages in retail settings.
Rayner, M; Wood, A; Lawrence, M; Mhurchu, C N; Albert, J; Barquera, S; Friel, S; Hawkes, C; Kelly, B; Kumanyika, S; L'abbé, M; Lee, A; Lobstein, T; Ma, J; Macmullan, J; Mohan, S; Monteiro, C; Neal, B; Sacks, G; Sanders, D; Snowdon, W; Swinburn, B; Vandevijvere, S; Walker, C
2013-10-01
Food labelling on food packaging has the potential to have both positive and negative effects on diets. Monitoring different aspects of food labelling would help to identify priority policy options to help people make healthier food choices. A taxonomy of the elements of health-related food labelling is proposed. A systematic review of studies that assessed the nature and extent of health-related food labelling has been conducted to identify approaches to monitoring food labelling. A step-wise approach has been developed for independently assessing the nature and extent of health-related food labelling in different countries and over time. Procedures for sampling the food supply, and collecting and analysing data are proposed, as well as quantifiable measurement indicators and benchmarks for health-related food labelling. © 2013 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of the International Association for the Study of Obesity.
Lasič, Eva; Galland, Fabiana; Vardjan, Nina; Šribar, Jernej; Križaj, Igor; Leite, Marina Concli; Zorec, Robert; Stenovec, Matjaž
2016-10-01
Astrocytes, the most heterogeneous glial cells in the central nervous system, contribute to brain homeostasis, by regulating a myriad of functions, including the clearance of extracellular debris. When cells are damaged, cytoplasmic proteins may exit into the extracellular space. One such protein is S100B, which may exert toxic effects on neighboring cells unless it is removed from the extracellular space, but the mechanisms of this clearance are poorly understood. By using time-lapse confocal microscopy and fluorescently labeled S100B (S100B-Alexa 488 ) and fluorescent dextran (Dextran 546 ), a fluid phase uptake marker, we examined the uptake of fluorescently labeled S100B-Alexa 488 from extracellular space and monitored trafficking of vesicles that internalized S100B-Alexa 488 . Initially, S100B-Alexa 488 and Dextran 546 internalized with distinct rates into different endocytotic vesicles; S100B-Alexa 488 internalized into smaller vesicles than Dextran 546 . At a later stage, S100B-Alexa 488 -positive vesicles substantially co-localized with Dextran 546 -positive endolysosomes and with acidic LysoTracker-positive vesicles. Cell treatment with anti-receptor for advanced glycation end products (RAGE) antibody, which binds to RAGE, a 'scavenger receptor', partially inhibited uptake of S100B-Alexa 488 , but not of Dextran 546 . The dynamin inhibitor dynole 34-2 inhibited internalization of both fluorescent probes. Directional mobility of S100B-Alexa 488 -positive vesicles increased over time and was inhibited by ATP stimulation, an agent that increases cytosolic free calcium concentration ([Ca 2+ ] i ). We conclude that astrocytes exhibit RAGE- and dynamin-dependent vesicular mechanism to efficiently remove S100B from the extracellular space. If a similar process occurs in vivo, astroglia may mitigate the toxic effects of extracellular S100B by this process under pathophysiologic conditions. This study reveals the vesicular clearance mechanism of extracellular S100B in astrocytes. Initially, fluorescent S100B internalizes into smaller endocytotic vesicles than dextran molecules. At a later stage, both probes co-localize within endolysosomes. S100B internalization is both dynamin- and RAGE-dependent, whereas dextran internalization is dependent on dynamin. Vesicle internalization likely mitigates the toxic effects of extracellular S100B and other waste products. © 2016 International Society for Neurochemistry.
Lessons from UNSCOM and IAEA regarding remote monitoring and air sampling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dupree, S.A.
1996-01-01
In 1991, at the direction of the United Nations Security Council, UNSCOM and IAEA developed plans for On-going Monitoring and Verification (OMV) in Iraq. The plans were accepted by the Security Council and remote monitoring and atmospheric sampling equipment has been installed at selected sites in Iraq. The remote monitoring equipment consists of video cameras and sensors positioned to observe equipment or activities at sites that could be used to support the development or manufacture of weapons of mass destruction, or long-range missiles. The atmospheric sampling equipment provides unattended collection of chemical samples from sites that could be used tomore » support the development or manufacture of chemical weapon agents. To support OMV in Iraq, UNSCOM has established the Baghdad Monitoring and Verification Centre. Imagery from the remote monitoring cameras can be accessed in near-real time from the Centre through RIF communication links with the monitored sites. The OMV program in Iraq has implications for international cooperative monitoring in both global and regional contexts. However, monitoring systems such as those used in Iraq are not sufficient, in and of themselves, to guarantee the absence of prohibited activities. Such systems cannot replace on-site inspections by competent, trained inspectors. However, monitoring similar to that used in Iraq can contribute to openness and confidence building, to the development of mutual trust, and to the improvement of regional stability.« less
A Review of Player Monitoring Approaches in Basketball: Current Trends and Future Directions.
Fox, Jordan L; Scanlan, Aaron T; Stanton, Robert
2017-07-01
Fox, JL, Scanlan, AT, and Stanton, R. A review of player monitoring approaches in basketball: current trends and future directions. J Strength Cond Res 31(7): 2021-2029, 2017-Effective monitoring of players in team sports such as basketball requires an understanding of the external demands and internal responses, as they relate to training phases and competition. Monitoring of external demands and internal responses allows coaching staff to determine the dose-response associated with the imposed training load (TL), and subsequently, if players are adequately prepared for competition. This review discusses measures reported in the literature for monitoring the external demands and internal responses of basketball players during training and competition. The external demands of training and competition were primarily monitored using time-motion analysis, with limited use of microtechnology being reported. Internal responses during training were typically measured using hematological markers, heart rate, various TL models, and perceptual responses such as rating of perceived exertion (RPE). Heart rate was the most commonly reported indicator of internal responses during competition with limited reporting of hematological markers or RPE. These findings show a large discrepancy between the reporting of external and internal measures and training and competition demands. Microsensors, however, may be a practical and convenient method of player monitoring in basketball to overcome the limitations associated with current approaches while allowing for external demands and internal responses to be recorded simultaneously. The triaxial accelerometers of microsensors seem well suited for basketball and warrant validation to definitively determine their place in the monitoring of basketball players. Coaching staff should make use of this technology by tracking individual player responses across the annual plan and using real-time monitoring to minimize factors such as fatigue and injury risk.
Takahashi, Hakuo; Yoshika, Masamichi; Yokoi, Toyohiko
2013-01-01
Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E). A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010. The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines. All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines.
Affective modulation of external misattribution bias in source monitoring in schizophrenia.
Costafreda, S G; Brébion, G; Allen, P; McGuire, P K; Fu, C H Y
2008-06-01
Schizophrenic patients tend to attribute internal events to external agents, a bias that may be linked to positive symptoms. We investigated the effect of emotional valence on the cognitive bias. Male schizophrenic subjects (n=30) and an experimenter alternatively produced neutral and negative words. The subject then decided whether he or the experimenter had generated the item. External misattributions were more common than self-misattributions, and the bias was greater for patients with active hallucinations and delusions relative to patients in remission. Actively psychotic patients but not patients in remission were more likely to generate external misattributions with negative relative to neutral words. Affective modulation of the externalizing cognitive bias in source monitoring is evident in patients with hallucinations and delusions.
ERIC Educational Resources Information Center
Huettig, Falk; Hartsuiker, Robert J.
2010-01-01
Theories of verbal self-monitoring generally assume an internal (pre-articulatory) monitoring channel, but there is debate about whether this channel relies on speech perception or on production-internal mechanisms. Perception-based theories predict that listening to one's own inner speech has similar behavioural consequences as listening to…
Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti
2014-09-01
To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.
Strategic Plan for the Spanish Academy of Dermatology and Venerology (AEDV): FuturAEDV 2013-2017.
Ribera Pibernat, M; Moreno Jiménez, J C; Valcuende Cavero, F; Soto de Delás, J; Vázquez Veiga, H; Lázaro Ochaíta, P; Giménez Arnau, A
2014-09-01
The Spanish Academy of Dermatology and Venereology (AEDV) has decided that a Strategic Plan is needed to help the association adapt to new circumstances and anticipate future developments. 1) To position the AEDV as a medical association that can exert an influence in everything related to dermatology. 2) To contribute to the development of the specialty, strengthening the prestige and reputation of dermatology and dermatologists. 3) To establish a model for operating and strategic thinking that can be handed on to successive Boards of Directors and will enable the Academy to identify future challenges. The approach used to develop the Strategic Plan was as follows: analysis of trends in the health care system; assessment of the current situation of AEDV and of dermatology in general through an internal analysis based on surveys and interviews with academics; analysis of strengths, weaknesses, opportunities, and threats; preparation of a mission statement; and identification, development, and implementation of a strategy map prioritizing strategic lines of action. The strategy map set out 16 general goals grouped into 4 main topics (achieving the vision, internal and external customers, internal processes, and innovation) and detailed in an action plan with 19 initiatives, each with specific actions. The plan will be monitored by the Strategic Plan Monitoring Committee, which is made up of the members of the Standing Committee and the chairs of the 9 Technical Committees responsible for implementing the initiatives. The Functional Plan should guide the management of AEDV until 2017, and its implementation will enable the association to contribute to the development and prestige of the specialty and position itself as a reference in terms of its functional model. Copyright © 2014 Elsevier España, S.L.U. y AEDV. All rights reserved.
Das, Amaresh; Spackman, Erica; Senne, Dennis; Pedersen, Jan; Suarez, David L.
2006-01-01
We developed an internal positive control (IPC) RNA to help ensure the accuracy of the detection of avian influenza virus (AIV) RNA by reverse transcription (RT)-PCR and real-time RT-PCR (RRT-PCR). The IPC was designed to have the same binding sites for the forward and reverse primers of the AIV matrix gene as the target amplicon, but it had a unique internal sequence used for the probe site. The amplification of the viral RNA and the IPC by RRT-PCR were monitored with two different fluorescent probes in a multiplex format, one specific for the AIV matrix gene and the other for the IPC. The RRT-PCR test was further simplified with the use of lyophilized bead reagents for the detection of AIV RNA. The RRT-PCR with the bead reagents was more sensitive than the conventional wet reagents for the detection of AIV RNA. The IPC-based RRT-PCR detected inhibitors in blood, kidney, lungs, spleen, intestine, and cloacal swabs, but not allantoic fluid, serum, or tracheal swabs The accuracy of RRT-PCR test results with the lyophilized beads was tested on cloacal and tracheal swabs from experimental birds inoculated with AIV and compared with virus isolation (VI) on embryonating chicken eggs. There was 97 to 100% agreement of the RRT-PCR test results with VI for tracheal swabs and 81% agreement with VI for cloacal swabs, indicating a high level of accuracy of the RRT-PCR assay. The same IPC in the form of armored RNA was also used to monitor the extraction of viral RNA and subsequent detection by RRT-PCR. PMID:16954228
Du, Guofeng; Zhang, Juan; Zhang, Jicheng; Song, Gangbing
2017-08-22
The filling of thin-walled steel tubes with quartz sand can help to prevent the premature buckling of the steel tube at a low cost. During an impact, the internal stress of the quartz sand-filled steel tube column is subjected to not only axial force but also lateral confining force, resulting in complicated internal stress. A suitable sensor for monitoring the internal stress of such a structure under an impact is important for structural health monitoring. In this paper, piezoceramic Smart Aggregates (SAs) are embedded into a quartz Sand-Filled Steel Tube Column (SFSTC) to monitor the internal structural stress during impacts. The piezoceramic smart aggregates are first calibrated by an impact hammer. Tests are conducted to study the feasibility of monitoring the internal stress of a structure. The results reflect that the calibration value of the piezoceramic smart aggregate sensitivity test is in good agreement with the theoretical value, and the output voltage value of the piezoceramic smart aggregate has a good linear relationship with external forces. Impact tests are conducted on the sand-filled steel tube with embedded piezoceramic smart aggregates. By analyzing the output signal of the piezoceramic smart aggregates, the internal stress state of the structure can be obtained. Experimental results demonstrated that, under the action of impact loads, the piezoceramic smart aggregates monitor the compressive stress at different locations in the steel tube, which verifies the feasibility of using piezoceramic smart aggregate to monitor the internal stress of a structure.
Prospects for Interdisciplinary Science Aboard the International Space Station
NASA Technical Reports Server (NTRS)
Robinson, Julie A.
2011-01-01
The assembly of the International Space Station was completed in early 2011, and is now embarking on its first year of the coming decade of use as a laboratory. Two key types of physical science research are enabled by ISS: studies of processes that are normally masked by gravity, and instruments that take advantage of its position as a powerful platform in orbit. The absence of buoyancy-driven convection enables experiments in diverse areas such as fluids near the critical point, Marangoni convection, combustion, and coarsening of metal alloys. The positioning of such a powerful platform in orbit with robotic transfer and instrument support also provides a unique alternative platform for astronomy and physics instruments. Some of the operating or planned instruments related to fundamental physics on the International Space Station include MAXI (Monitoring all-sky X-ray Instrument for ISS), the Alpha Magnetic Spectrometer, CALET (Calorimetric Electron Telescope), and ACES (Atomic Clock Experiment in Space). The presentation will conclude with an overview of pathways for funding different types of experiments from NASA funding to the ISS National Laboratory, and highlights of the streamlining of services to help scientists implement their experiments on ISS.
Optimization of EGFR high positive cell isolation procedure by design of experiments methodology.
Levi, Ofer; Tal, Baruch; Hileli, Sagi; Shapira, Assaf; Benhar, Itai; Grabov, Pavel; Eliaz, Noam
2015-01-01
Circulating tumor cells (CTCs) in blood circulation may play a role in monitoring and even in early detection of metastasis patients. Due to the limited presence of CTCs in blood circulation, viable CTCs isolation technology must supply a very high recovery rate. Here, we implement design of experiments (DOE) methodology in order to optimize the Bio-Ferrography (BF) immunomagnetic isolation (IMI) procedure for the EGFR high positive CTCs application. All consequent DOE phases such as screening design, optimization experiments and validation experiments were used. A significant recovery rate of more than 95% was achieved while isolating 100 EGFR high positive CTCs from 1 mL human whole blood. The recovery achievement in this research positions BF technology as one of the most efficient IMI technologies, which is ready to be challenged with patients' blood samples. © 2015 International Clinical Cytometry Society.
Measurement of axial injection displacement with trim coil current unbalance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Covo, Michel Kireeff, E-mail: mkireeffcovo@lbl.gov
The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.
Application of the SCADA system in wastewater treatment plants.
Dieu, B
2001-01-01
The implementation of the SCADA system has a positive impact on the operations, maintenance, process improvement and savings for the City of Houston's Wastewater Operations branch. This paper will discuss the system's evolvement, the external/internal architecture, and the human-machine-interface graphical design. Finally, it will demonstrate the system's successes in monitoring the City's sewage and sludge collection/distribution systems, wet-weather facilities and wastewater treatment plants, complying with the USEPA requirements on the discharge, and effectively reducing the operations and maintenance costs.
Cronk, Ryan; Slaymaker, Tom; Bartram, Jamie
2015-11-01
Inadequate drinking water, sanitation, and hygiene (WaSH) in non-household settings, such as schools, health care facilities, and workplaces impacts the health, education, welfare, and productivity of populations, particularly in low and middle-income countries. There is limited knowledge on the status of WaSH in such settings. To address this gap, we reviewed international standards, international and national actors, and monitoring initiatives; developed the first typology of non-household settings; and assessed the viability of monitoring. Based on setting characteristics, non-household settings include six types: schools, health care facilities, workplaces, temporary use settings, mass gatherings, and dislocated populations. To-date national governments and international actors have focused monitoring of non-household settings on schools and health care facilities with comparatively little attention given to other settings such as workplaces and markets. Nationally representative facility surveys and national management information systems are the primary monitoring mechanisms. Data suggest that WaSH coverage is generally poor and often lower than in corresponding household settings. Definitions, indicators, and data sources are underdeveloped and not always comparable between countries. While not all countries monitor non-household settings, examples are available from countries on most continents suggesting that systematic monitoring is achievable. Monitoring WaSH in schools and health care facilities is most viable. Monitoring WaSH in other non-household settings would be viable with: technical support from local and national actors in addition to international organizations such as WHO and UNICEF; national prioritization through policy and financing; and including WaSH indicators into monitoring initiatives to improve cost-effectiveness. International consultations on targets and indicators for global monitoring of WaSH post-2015 identified non-household settings as a priority. National and international monitoring systems will be important to better understand status, trends, to identify priorities and target resources accordingly, and to improve accountability for progressive improvements in WaSH in non-household settings. Copyright © 2015 Elsevier GmbH. All rights reserved.
CCSDS - Advancing Spaceflight Technology for International Collaboration
NASA Technical Reports Server (NTRS)
Kearney, Mike; Kiely, Aaron; Yeh, Penshu; Gerner, Jean-Luc; Calzolari, Gian-Paolo; Gifford, Kevin; Merri, Mario; Weiss, Howard
2010-01-01
The Consultative Committee for Space Data Systems (CCSDS) has been developing data and communications standards since 1982, with the objective of providing interoperability for enabling international collaboration for spaceflight missions. As data and communications technology has advanced, CCSDS has progressed to capitalize on existing products when available and suitable for spaceflight, and to develop innovative new approaches when available products fail. The current scope of the CCSDS architecture spans the end-to-end data architecture of a spaceflight mission, with ongoing efforts to develop and standardize cutting-edge technology. This manuscript describes the overall architecture, the position of CCSDS in the standards and international mission community, and some CCSDS processes. It then highlights in detail several of the most interesting and critical technical areas in work right now, and how they support collaborative missions. Special topics include: Delay/Disruption Tolerant Networking (DTN), Asynchronous Message Service (AMS), Multispectral/Hyperspectral Data Compression (MHDC), Coding and Synchronization, Onboard Wireless, Spacecraft Monitor and Control, Navigation, Security, and Time Synchronization/Correlation. Broad international participation in development of CCSDS standards is encouraged.
Conference report. Women's perspectives: keeping a close watch.
Datta, B
1994-01-01
Most individuals in the women's movement are happy with the accomplishments of the 1994 International Conference on Population and Development (ICPD). Activists were able to introduce feminist discourse into world governments and have a term like "gender equality" used as freely as "mother's milk." Some women, however, critique that the conference will do little to empower women in any real sense. Whatever the long-term effects, it is clear that women and women's groups were required to put aside their confrontational politics and adopt a more organized, collaborative approach. The Women's Caucus at Cairo created Women Watching ICPD, a group to monitor if governments, donors, and service providers follow through with the commitments they made at the conference. Six nongovernmental organizations (NGO) from the North and South have already agreed to participate in the task force. The group promises to ensure an end to coercion and to make certain that positive recommendations are implemented. It will watch budgets, allocation processes, and decision makers, and try to ensure that NGOs monitoring international financial institutions make gender efforts central to their efforts.
Zhong, D; Zhou, Y; Li, Y; Wang, Y; Zhou, W; Cheng, Q; Chen, L; Zhao, J; Li, X; Yan, X
2014-07-01
It is well accepted that recurrent laryngeal nerve paralysis is a severe complication of esophagectomy or lymphadenectomy performed adjacent to the recurrent laryngeal nerves. Herein, determination of the effectiveness of implementing continuous recurrent laryngeal nerve monitoring to reduce the incidence of recurrent laryngeal nerve paralysis after esophagectomy was sought. A total of 115 patients diagnosed with esophageal cancer were enrolled in the thoracic section of the Tangdu Hospital of the Fourth Military Medical University from April 2008 to April 2009. Clinical parameters of patients, the morbidity, and the mortality following esophageal resection were recorded and compared. After the surgery, a 2-year follow up was completed. It was found that recurrent laryngeal nerve paralysis and postoperative pneumonia were more frequently diagnosed in the patients that did not receive continuous recurrent laryngeal nerve monitoring (6/61 vs. 0/54). Furthermore, positive mediastinal lymph nodes (P = 0.015), total mediastinal lymph nodes (P < 0.001), positive total lymph nodes (P = 0.027), and total lymph nodes (P < 0.001) were more often surgically removed in the patients with continuous recurrent laryngeal nerve monitoring. These patients also had a higher 2-year survival rate (P = 0.038) after surgery. It was concluded that continuous intraoperative recurrent laryngeal nerve monitoring is technically safe and effectively identifies the recurrent laryngeal nerves. This may be a helpful method for decreasing the incidence of recurrent laryngeal nerve paralysis and postoperative pneumonia, and for improving the efficiency of lymphadenectomy. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Near real-time PPP-based monitoring of the ionosphere using dual-frequency GPS/BDS/Galileo data
NASA Astrophysics Data System (ADS)
Liu, Zhinmin; Li, Yangyang; Li, Fei; Guo, Jinyun
2018-03-01
Ionosphere delay is very important to GNSS observations, since it is one of the main error sources which have to be mitigated even eliminated in order to determine reliable and precise positions. The ionosphere is a dispersive medium to radio signal, so the value of the group delay or phase advance of GNSS radio signal depends on the signal frequency. Ground-based GNSS stations have been used for ionosphere monitoring and modeling for a long time. In this paper we will introduce a novel approach suitable for single-receiver operation based on the precise point positioning (PPP) technique. One of the main characteristic is that only carrier-phase observations are used to avoid particular effects of pseudorange observations. The technique consists of introducing ionosphere ambiguity parameters obtained from PPP filter into the geometry-free combination of observations to estimate ionospheric delays. Observational data from stations that are capable of tracking the GPS/BDS/GALILEO from the International GNSS Service (IGS) Multi-GNSS Experiments (MGEX) network are processed. For the purpose of performance validation, ionospheric delays series derived from the novel approach are compared with the global ionospheric map (GIM) from Ionospheric Associate Analysis Centers (IAACs). The results are encouraging and offer potential solutions to the near real-time ionosphere monitoring.
A Web-based geographic information system for monitoring animal welfare during long journeys.
Ippoliti, Carla; Di Pasquale, Adriano; Fiore, Gianluca; Savini, Lara; Conte, Annamaria; Di Gianvito, Federica; Di Francesco, Cesare
2007-01-01
Animal welfare protection during long journeys is mandatory according to European Union regulations designed to ensure that animals are transported in accordance with animal welfare requirements and to provide control bodies with a regulatory tool to react promptly in cases of non-compliance and to ensure a safe network between products, animals and farms. Regulation 1/2005/EC foresees recourse to a system of traceability within European Union member states. The Joint Research Centre of the European Commission (JRC) has developed a prototype system fulfilling the requirements of the Regulation which is able to monitor compliance with animal welfare requirements during transportation, register electronic identification of transported animals and store data in a central database shared with the other member states through a Web-based application. Test equipment has recently been installed on a vehicle that records data on vehicle position (geographic coordinates, date/time) and animal welfare conditions (measurements of internal temperature of the vehicle, etc.). The information is recorded at fixed intervals and transmitted to the central database. The authors describe the Web-based geographic information system, through which authorised users can visualise instantly the real-time position of the vehicle, monitor the sensor-recorded data and follow the time-space path of the truck during journeys.
Hinckley, Christopher A; Alaynick, William A; Gallarda, Benjamin W; Hayashi, Marito; Hilde, Kathryn L; Driscoll, Shawn P; Dekker, Joseph D; Tucker, Haley O; Sharpee, Tatyana O; Pfaff, Samuel L
2015-09-02
The coordination of multi-muscle movements originates in the circuitry that regulates the firing patterns of spinal motorneurons. Sensory neurons rely on the musculotopic organization of motorneurons to establish orderly connections, prompting us to examine whether the intraspinal circuitry that coordinates motor activity likewise uses cell position as an internal wiring reference. We generated a motorneuron-specific GCaMP6f mouse line and employed two-photon imaging to monitor the activity of lumbar motorneurons. We show that the central pattern generator neural network coordinately drives rhythmic columnar-specific motorneuron bursts at distinct phases of the locomotor cycle. Using multiple genetic strategies to perturb the subtype identity and orderly position of motorneurons, we found that neurons retained their rhythmic activity-but cell position was decoupled from the normal phasing pattern underlying flexion and extension. These findings suggest a hierarchical basis of motor circuit formation that relies on increasingly stringent matching of neuronal identity and position. Copyright © 2015 Elsevier Inc. All rights reserved.
Mitchell, John A; Pumpa, Kate L; Pyne, David B
2017-03-01
Mitchell, JA, Pumpa, KL, and Pyne, DB. Responses of lowerbody power and match running demands after long-haul travel in international rugby sevens players. J Strength Cond Res 31(3): 686-695, 2017-This study determined the effect of long-haul (>5 hours) travel on lower-body power and match running demands in international rugby sevens players. Lower-body power was assessed in 22 male international rugby sevens players (age 21.7 ± 2.7 years, mass 89.0 ± 6.7 kg, stature 180.5 ± 6.2 cm; mean ± SD) monitored over 17 rugby sevens tournaments. A countermovement jump was used to monitor lower-body power (peak and mean power) over repeated three week travel and competition periods (pretravel, posttravel, and posttournament). Small decreases were evident in peak power after both short and long-haul travel (-4.0%, ±3.2%; mean, ±90% confidence limits) with further reductions in peak and mean power posttournament (-4.5%, ±2.3% and -3.8%, ±1.5%) culminating in a moderate decrease in peak power overall (-7.4%, ±4.0%). A subset of 12 players (completing a minimum of 8 tournaments) had the effects of match running demands assessed with lower-body power. In this subset, long-haul travel elicited a large decrease in lower-body peak (-9.4%, ±3.5%) and mean power (-5.6%, ±2.9%) over the monitoring period, with a small decrease (-4.3%, ±3.0% and -2.2%, ±1.7%) posttravel and moderate decrease (-5.4%, ±2.5% and -3.5%, ±1.9%) posttournament, respectively. Match running demands were monitored through global positioning system. In long-haul tournaments, the 12 players covered ∼13%, ±13% greater total distance (meter) and ∼11%, ±10% higher average game meters >5 m·s when compared with short-haul (<5 hours) travel. Effective pretravel and posttravel player management strategies are indicated to reduce neuromuscular fatigue and running load demands in rugby sevens tournaments after long-haul travel.
Source monitoring in Korsakoff's syndrome: "Did I touch the toothbrush or did I imagine doing so?"
El Haj, Mohamad; Nandrino, Jean Louis; Coello, Yann; Miller, Ralph; Antoine, Pascal
2017-06-01
There is a body of research suggesting compromised ability to distinguish between different external sources of information (i.e., external monitoring) in Korsakoff's syndrome. Here we replicate and extend this literature by assessing the ability of patients with Korsakoff's syndrome to distinguish between different external sources of information (i.e., external monitoring), between internal and external sources of information (i.e., reality monitoring), and between different internal sources of information (i.e., internal monitoring). On the external monitoring assessment, patients with Korsakoff's syndrome and controls watched the experimenter place objects (e.g., a toothbrush) in either a black or white box; afterward, they were asked to remember where the objects had been placed. On the reality monitoring assessment, participants had to either place objects or watch the experimenter place objects in a black box; afterward, they were asked to remember whether the objects had been placed in the box by themselves or by the experimenter. On the internal monitoring assessment, participants had to either place objects or imagine themselves placing objects in a black box; afterward, they were asked to remember whether they had previously placed the objects in the box or imagined doing so. Analyses demonstrated lower external and internal monitoring in patients with Korsakoff's syndrome than in controls, but no significant difference was observed between the two populations on the reality monitoring condition. Our data provide preliminary evidence that the ability to recognize oneself as the author of one's own actions may be relatively preserved in Korsakoff's syndrome. Copyright © 2017 Elsevier Ltd. All rights reserved.
50 CFR 300.45 - Vessel Monitoring System.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Vessel Monitoring System. 300.45 Section 300.45 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.45 Vessel Monitoring System. (a) Applicability. Holders of...
50 CFR 300.45 - Vessel Monitoring System.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Vessel Monitoring System. 300.45 Section 300.45 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.45 Vessel Monitoring System. (a) Applicability. Holders of...
Moshki, M; Ashtarian, H
2010-01-01
Background: Health locus of control (HLC) has been associated with a variety of ailments and health outcomes and designed to predict behaviors and cognitive processes relevant to mental and physical health. This study investigated the relationships between perceived health locus of control, self-esteem, and mental health status among Iranian students. Methods: In this analytical study the subjects were recruited from students in Gonabad University of Medical Sciences, Iran, who studied in the first year (N=154). Students completed the questionnaires for assessing demographic, perceived health locus of control, self - esteem and psychological well- being data. Results: The statistical analysis revealed a negative relationship between perceived Internal HLC and self-esteem with psychological well-being. The positive correlation of the perceived Chance HLC with psychological well-being was statistically significant (r= 0.21, P< 0.01) and the positive correlation of the perceived Internal HLC with self-esteem was statistically significant (r= 0.25, P< 0.01). A significantly direct relationship between low perceived Internal HLC, self–esteem and psychological problems was found among these students. Conclusion: The findings will be addressed in relation to their implications for effective mental health education based on health locus of control especially internal and powerful others beliefs associated with self-esteem for students. This will require additional monitoring and uninterrupted trying in order to be effective. PMID:23113040
Goldner, Jonathan S; Quimby, Dakari; Richards, Maryse H; Zakaryan, Arie; Miller, Steve; Dickson, Daniel; Chilson, Jessica
2016-01-01
Parental monitoring and warmth have traditionally been studied in the context of White, middle-class families. This article explores optimal levels of these parenting behaviors in preventing adolescent psychopathology in impoverished, urban high-crime areas while accounting for child perceptions of neighborhood danger. In this study, data were collected longitudinally at 2 time points 1 year apart from a sample of 254 African American young adolescents (T1: M age = 12.6 years, 41% male) and their parents. Parental monitoring and warmth, child perception of neighborhood danger, and child internalizing and externalizing behaviors were measured using questionnaires. Child internalizing behaviors were also measured using a time sampling technique capturing in vivo accounts of daily distress. Findings indicated associations between parental monitoring and children's externalizing behaviors along with linear and quadratic associations between parental monitoring and internalizing behaviors. Monitoring and warmth were differentially related to symptoms depending on neighborhood danger level. When children perceived less danger, more monitoring related to less externalizing. When children perceived more danger, more warmth related to less internalizing. In addition, adolescents' perceptions of neighborhood danger emerged as equally strong as monitoring and warmth in predicting symptoms. This study underscores the influence of carefully considering parenting approaches and which techniques optimally prevent adolescents' externalizing, as well as prevent internalizing difficulties. It also highlights how context affects mental health, specifically how perceptions of danger negatively influence adolescents' psychopathology, emphasizing the importance of initiatives to reduce violence in communities.
NASA Astrophysics Data System (ADS)
Baillargeon, Jacques Guy
Though well-documented among numerous cohorts of male workers, little is known about how the healthy worker effect (HWE) and the internal HWE is expressed among cohorts of female workers. This investigation examines characteristics of the HWE and the internal HWE in a cohort of 12,668 female nuclear workers. The HWE, which was estimated by assessing SMRs for all causes of death combined, was found to be modified by race, occupational class and length of follow-up. Smaller variations in the HWE were observed for age at hire, occupational class, length of employment, monitored status, and interruption of monitoring. Examination of SMRs for all cancers combined revealed that the HWE was modified by race, occupational class, monitored status, interruption of monitoring, and length of follow-up. Smaller variations were observed for age at hire and length of employment. Investigators often try to circumvent the HWE by employing internal comparisons; that is, by directly comparing the mortality of subgroups within a defined occupational cohort with one another. However, internal comparisons are not necessarily free from certain biases related to the HWE. If employees are selected on the basis of health into subgroups which serve as the basis for internal comparisons, then a form of internal comparison bias, called the internal healthy worker effect (Stewart et al, 1991; Wilkinson, 1992) may occur. In this investigation, the expression of the internal HWE was examined by estimating the extent to which survival time was modified by the variables under study. Using the Cox PH model, time to death from all causes was found to be modified by occupational class and length of employment but not by race, age at hire, monitored status, or interruption of monitoring. Time to death from all cancers was found to be modified by race and interruption of monitoring but not by age at hire, occupational class, length of employment, or monitored status. These results are important because they may provide leads for other investigators to determine whether the exposure-disease relationships are confounded by characteristics of the employed female populations under study.
Internal fetal monitoring (image)
Internal fetal monitoring involves placing a electrode directly on the fetal scalp through the cervix. This test is performed to evaluate fetal heart rate and variability between beats, especially ...
Construction and Operation of an Internal Coil Device, RT-1, with a High-Temperature Superconductor
NASA Astrophysics Data System (ADS)
Ogawa, Yuichi; Yoshida, Zensho; Morikawa, Junji; Saito, Haruhiko; Watanabe, Sho; Yano, Yoshihisa; Mizumaki, Shoichi; Tosaka, Taizo
An internal coil device called Ring Trap-1 (RT-1) has been constructed to explore an innovative concept for a high-beta plasma based on a new relaxation theory. A high-temperature superconductor (HTS) Bi-2223 tape is employed for the internal coil of RT-1. The coil is cooled to 20 K with helium gas supplied by G-M refrigerators, and charged to a magnetomotive force of 250 kA using an external power supply. For these cooling and charging methods, we have developed several innovative techniques such as a demountable transfer tube system, persistent current switch, detachable electrode, and others. In addition, we have paid much attention to the deterioration of the HTS tape during the fabrication of the internal coil. As a result, we have demonstrated that the decay of the persistent current of the internal coil is ˜1% during 8 h. The internal coil is lifted with a levitation coil located at the upper region of the vacuum vessel. The coil position monitored with laser sensors is feedback controlled through the regulation of the levitation coil current. Stable levitation for a few hours has been demonstrated for various plasma experiments.
Rock Burst Monitoring by Integrated Microseismic and Electromagnetic Radiation Methods
NASA Astrophysics Data System (ADS)
Li, Xuelong; Wang, Enyuan; Li, Zhonghui; Liu, Zhentang; Song, Dazhao; Qiu, Liming
2016-11-01
For this study, microseismic (MS) and electromagnetic radiation (EMR) monitoring systems were installed in a coal mine to monitor rock bursts. The MS system monitors coal or rock mass ruptures in the whole mine, whereas the EMR equipment monitors the coal or rock stress in a small area. By analysing the MS energy, number of MS events, and EMR intensity with respect to rock bursts, it has been shown that the energy and number of MS events present a "quiet period" 1-3 days before the rock burst. The data also show that the EMR intensity reaches a peak before the rock burst and this EMR intensity peak generally corresponds to the MS "quiet period". There is a positive correlation between stress and EMR intensity. Buckling failure of coal or rock depends on the rheological properties and occurs after the peak stress in the high-stress concentration areas in deep mines. The MS "quiet period" before the rock burst is caused by the heterogeneity of the coal and rock structures, the transfer of high stress into internal areas, locked patches, and self-organized criticality near the stress peak. This study increases our understanding of coal and rock instability in deep mines. Combining MS and EMR to monitor rock burst could improve prediction accuracy.
An embedded stress sensor for concrete SHM based on amorphous ferromagnetic microwires.
Olivera, Jesús; González, Margarita; Fuente, José Vicente; Varga, Rastislav; Zhukov, Arkady; Anaya, José Javier
2014-10-24
A new smart concrete aggregate design as a candidate for applications in structural health monitoring (SHM) of critical elements in civil infrastructure is proposed. The cement-based stress/strain sensor was developed by utilizing the stress/strain sensing properties of a magnetic microwire embedded in cement-based composite (MMCC). This is a contact-less type sensor that measures variations of magnetic properties resulting from stress variations. Sensors made of these materials can be designed to satisfy the specific demand for an economic way to monitor concrete infrastructure health. For this purpose, we embedded a thin magnetic microwire in the core of a cement-based cylinder, which was inserted into the concrete specimen under study as an extra aggregate. The experimental results show that the embedded MMCC sensor is capable of measuring internal compressive stress around the range of 1-30 MPa. Two stress sensing properties of the embedded sensor under uniaxial compression were studied: the peak amplitude and peak position of magnetic switching field. The sensitivity values for the amplitude and position within the measured range were 5 mV/MPa and 2.5 µs/MPa, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mark Schanfein
Nuclear material safeguards specialists and instrument developers at US Department of Energy (USDOE) National Laboratories in the United States, sponsored by the National Nuclear Security Administration (NNSA) Office of NA-24, have been developing devices to monitor shipments of UF6 cylinders and other radioactive materials , . Tracking devices are being developed that are capable of monitoring shipments of valuable radioactive materials in real time, using the Global Positioning System (GPS). We envision that such devices will be extremely useful, if not essential, for monitoring the shipment of these important cargoes of nuclear material, including highly-enriched uranium (HEU), mixed plutonium/uranium oxidemore » (MOX), spent nuclear fuel, and, potentially, other large radioactive sources. To ensure nuclear material security and safeguards, it is extremely important to track these materials because they contain so-called “direct-use material” which is material that if diverted and processed could potentially be used to develop clandestine nuclear weapons . Large sources could be used for a dirty bomb also known as a radioactive dispersal device (RDD). For that matter, any interdiction by an adversary regardless of intent demands a rapid response. To make the fullest use of such tracking devices, we propose a National Tracking Center. This paper describes what the attributes of such a center would be and how it could ultimately be the prototype for an International Tracking Center, possibly to be based in Vienna, at the International Atomic Energy Agency (IAEA).« less
Gender equality observations and actions by the European Research Council
NASA Astrophysics Data System (ADS)
Rydin, Claudia Alves de Jesus; Farina Busto, Luis; Penny, Martin
2016-04-01
Women have historically been underrepresented in science. Much positive progress in attracting women to research careers has been achieved in recent years; however, the most influential and high profile positions in most countries are still predominantly occupied by men. The European Research Council (ERC), Europe's premiere funding agency for frontier research, views gender equality as an important challenge. The ERC monitors closely gender figures on every call and has taken actions to tackle gender imbalances and potential unconscious biases. The ERC talk is focused on efforts made to understand and ensure equal treatment of all candidates, with particular focus on gender balance and with specific attention to geosciences. Data and statistics collected from ERC's internationally recognised funding schemes are presented.
ERIC Educational Resources Information Center
Rockefeller Foundation, New York, NY.
The proceedings of a conference on international environmental monitoring is presented, along with a commentary, reports from activity groups, and appended tabular information. Major objectives of the 25 participants from international organizations, national governments, and research institutions were to review accomplishments in global and…
Tiernan, Kristine; Foster, Sharon L; Cunningham, Phillippe B; Brennan, Patricia; Whitmore, Elizabeth
2015-03-01
This study examined individual and family characteristics that predicted early positive change in the context of Multisystemic Therapy (MST). Families (n = 185; 65% male; average youth age 15 years) receiving MST in community settings completed assessments at the outset of treatment and 6-12 weeks into treatment. Early positive changes in youth antisocial behavior were assessed using the caregiver report on the Child Behavior Checklist Externalizing Behaviors subscale and youth report on the Self-Report Delinquency Scale. Overall, families showed significant positive changes by 6-12 weeks into treatment; these early changes were maintained into midtreatment 6-12 weeks later. Families who exhibited clinically significant gains early in treatment were more likely to terminate treatment successfully compared with those who did not show these gains. Low youth internalizing behaviors and absence of youth drug use predicted early positive changes in MST. High levels of parental monitoring and low levels of affiliation with deviant peers (mechanisms known to be associated with MST success) were also associated with early positive change. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Comprehensive seismic monitoring of the Cascadia megathrust with real-time GPS
NASA Astrophysics Data System (ADS)
Melbourne, T. I.; Szeliga, W. M.; Santillan, V. M.; Scrivner, C. W.; Webb, F.
2013-12-01
We have developed a comprehensive real-time GPS-based seismic monitoring system for the Cascadia subduction zone based on 1- and 5-second point position estimates computed within the ITRF08 reference frame. A Kalman filter stream editor that uses a geometry-free combination of phase and range observables to speed convergence while also producing independent estimation of carrier phase biases and ionosphere delay pre-cleans raw satellite measurements. These are then analyzed with GIPSY-OASIS using satellite clock and orbit corrections streamed continuously from the International GNSS Service (IGS) and the German Aerospace Center (DLR). The resulting RMS position scatter is less than 3 cm, and typical latencies are under 2 seconds. Currently 31 coastal Washington, Oregon, and northern California stations from the combined PANGA and PBO networks are analyzed. We are now ramping up to include all of the remaining 400+ stations currently operating throughout the Cascadia subduction zone, all of which are high-rate and telemetered in real-time to CWU. These receivers span the M9 megathrust, M7 crustal faults beneath population centers, several active Cascades volcanoes, and a host of other hazard sources. To use the point position streams for seismic monitoring, we have developed an inter-process client communication package that captures, buffers and re-broadcasts real-time positions and covariances to a variety of seismic estimation routines running on distributed hardware. An aggregator ingests, re-streams and can rebroadcast up to 24 hours of point-positions and resultant seismic estimates derived from the point positions to application clients distributed across web. A suite of seismic monitoring applications has also been written, which includes position time series analysis, instantaneous displacement vectors, and peak ground displacement contouring and mapping. We have also implemented a continuous estimation of finite-fault slip along the Cascadia megathrust using a NIF-type approach. This currently operates on the terrestrial GPS data streams, but could readily be expanded to use real-time offshore geodetic measurements as well. The continuous slip distributions are used in turn to compute tsunami excitation and, when convolved with pre-computed, hydrodynamic Green functions calculated using the COMCOT tsunami modeling software, run-up estimates for the entire Cascadia coastal margin. Finally, a suite of data visualization tools has been written to allow interaction with the real-time position streams and seismic estimates based on them, including time series plotting, instantaneous offset vectors, peak ground deformation contouring, finite-fault inversions, and tsunami run-up. This suite is currently bundled within a single client written in JAVA, called ';GPS Cockpit,' which is available for download.
Stauffer, Fritz; Haber, Heinrich; Rieger, Armin; Mutschlechner, Robert; Hasenberger, Petra; Tevere, Vincent J.; Young, Karen K. Y.
1998-01-01
An easy-to-handle Mycobacterium-specific PCR assay for detection of the presence of a wide range of mycobacterial species in clinical samples was evaluated. The performance of the genus probe was compared with the performance of probes specific for Mycobacterium tuberculosis and Mycobacterium avium and with that of standard culture. In addition, the utility of an internal control in monitoring amplification inhibitors was studied. Of 545 respiratory and 325 nonrespiratory specimens (a total of 870 specimens), 58 (6.7%) showed the presence of amplification inhibitors, as determined by a negative result for the internal control. Of these 58 specimens, 31 (53%) were stool specimens; other material, even citrate blood after lysis of erythrocytes, did not pose a problem with regard to inhibition of PCR amplification. Eighty-one of the remaining 812 specimens had a positive Mycobacterium culture result. Of these culture-positive specimens, 58 (71.6%) showed a positive result with the Mycobacterium genus-specific probe. Seventy-two samples had a positive result with the Mycobacterium-specific probe but a negative culture result. Of these 72 samples, 26 samples were regarded as true positive, either because the M. tuberculosis- or M. avium-specific probe was also positive at the same time or because other specimens from the same patient taken at the same time were culture positive. The sensitivity of the Mycobacterium-specific probe was 78.5% and the specificity was 93.5%. This study showed that pretesting of clinical specimens for mycobacteria to the genus level with a Mycobacterium-specific probe offers the routine clinical laboratory the possibility of detecting tuberculous and nontuberculous mycobacteria with one test. Furthermore, specimens testing positive with the genus-specific probe can be immediately identified with species-specific probes. PMID:9508282
Radiological assessment for bauxite mining and alumina refining.
O'Connor, Brian H; Donoghue, A Michael; Manning, Timothy J H; Chesson, Barry J
2013-01-01
Two international benchmarks assess whether the mining and processing of ores containing Naturally Occurring Radioactive Material (NORM) require management under radiological regulations set by local jurisdictions. First, the 1 Bq/g benchmark for radionuclide head of chain activity concentration determines whether materials may be excluded from radiological regulation. Second, processes may be exempted from radiological regulation where occupational above-background exposures for members of the workforce do not exceed 1 mSv/year. This is also the upper-limit of exposure prescribed for members of the public. Alcoa of Australia Limited (Alcoa) has undertaken radiological evaluations of the mining and processing of bauxite from the Darling Range of Western Australia since the 1980s. Short-term monitoring projects have demonstrated that above-background exposures for workers do not exceed 1 mSv/year. A whole-of-year evaluation of above-background, occupational radiological doses for bauxite mining, alumina refining and residue operations was conducted during 2008/2009 as part of the Alcoa NORM Quality Assurance System (NQAS). The NQAS has been guided by publications from the International Commission on Radiological Protection (ICRP), the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). The NQAS has been developed specifically in response to implementation of the Australian National Directory on Radiation Protection (NDRP). Positional monitoring was undertaken to increase the accuracy of natural background levels required for correction of occupational exposures. This is important in view of the small increments in exposure that occur in bauxite mining, alumina refining and residue operations relative to natural background. Positional monitoring was also undertaken to assess the potential for exposure in operating locations. Personal monitoring was undertaken to characterise exposures in Similar Exposure Groups (SEGs). The monitoring was undertaken over 12 months, to provide annual average assessments of above-background doses, thereby reducing temporal variations, especially for radon exposures. The monitoring program concentrated on gamma and radon exposures, rather than gross alpha exposures, as past studies have shown that gross alpha exposures from inhalable dust for most of the workforce are small in comparison to combined gamma and radon exposures. The natural background determinations were consistent with data in the literature for localities near Alcoa's mining, refining and residue operations in Western Australia, and also with UNSCEAR global data. Within the mining operations, there was further consistency between the above-background dose estimates and the local geochemistry, with slight elevation of dose levels in mining pits. Conservative estimates of above-background levels for the workforce have been made using an assumption of 100% occupancy (1920 hours per year) for the SEGs considered. Total incremental composite doses for individuals were clearly less than 1.0 mSv/year when gamma, radon progeny and gross alpha exposures were considered. This is despite the activity concentration of some materials being slightly higher than the benchmark of 1 Bq/g. The results are consistent with previous monitoring and demonstrate compliance with the 1 mSv/year exemption level within mining, refining and residue operations. These results will be of value to bauxite mines and alumina refineries elsewhere in the world.
Monitoring internal organ motion with continuous wave radar in CT.
Pfanner, Florian; Maier, Joscha; Allmendinger, Thomas; Flohr, Thomas; Kachelrieß, Marc
2013-09-01
To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT. The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements. Concerning the measurements of the test persons, there is a very good correlation (ρ = 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements. A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.
Ansermot, Nicolas; Brawand-Amey, Marlyse; Kottelat, Astrid; Eap, Chin B
2013-05-31
A sensitive and selective ultra-high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was developed for the fast quantification of ten psychotropic drugs and metabolites in human plasma for the needs of our laboratory (amisulpride, asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, norquetiapine, olanzapine, paliperidone, quetiapine and risperidone). Stable isotope-labeled internal standards were used for all analytes, to compensate for the global method variability, including extraction and ionization variations. Sample preparation was performed by generic protein precipitation with acetonitrile. Chromatographic separation was achieved in less than 3.0min on an Acquity UPLC BEH Shield RP18 column (2.1mm×50mm; 1.7μm), using a gradient elution of 10mM ammonium formate buffer pH 3.0 and acetonitrile at a flow rate of 0.4ml/min. The compounds were quantified on a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The method was fully validated according to the latest recommendations of international guidelines. Eight point calibration curves were used to cover a large concentration range 0.5-200ng/ml for asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, olanzapine, paliperidone and risperidone, and 1-1500ng/ml for amisulpride, norquetiapine and quetiapine. Good quantitative performances were achieved in terms of trueness (93.1-111.2%), repeatability (1.3-8.6%) and intermediate precision (1.8-11.5%). Internal standard-normalized matrix effects ranged between 95 and 105%, with a variability never exceeding 6%. The accuracy profiles (total error) were included in the acceptance limits of ±30% for biological samples. This method is therefore suitable for both therapeutic drug monitoring and pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Peter E. Koestner; Karen A. Koestner; Daniel G. Neary
2012-01-01
The Sierra Ancha International Cooperative Program on Assessment and Monitoring of Air Pollution Effects on Forests study site or (SAEF-ICP II) is part of an international network of cooperative forest monitoring sites spread throughout Europe and the United States. The United Nations Economic Commission for Europe established the ICP II network in 1985 to monitor long...
Ibrahim, George M; Cadotte, David W; Bernstein, Mark
2015-01-01
An estimated two billion people worldwide lack adequate access to surgical care. To address this humanitarian emergency, an increasing number of international surgical partnerships are emerging between developed and low- and middle-income countries (LMICs). At present, there are no clear indicators that may be used to assess the effectiveness of such initiatives. We conducted an international qualitative study of 31 surgeons from developed and LMICs involved in international partnerships across a variety of subspecialties. Thematic analysis and grounded theory were applied in order to develop a practical framework that may be applied to monitor and evaluate global surgical initiatives. Several themes emerged from the study: (i) there is a large unmet need to establish and maintain prospective databases in LMICs to inform the monitoring and evaluation of international surgical partnerships; (ii) assessment of initiatives must occur longitudinally over the span of several years; (ii) the domains of assessment are contextual and encompass cultural, institutional and regional factors; and (iv) evaluation strategies should explore broader impact within the community and country. Based on thematic analysis within the domains of inputs, outputs and outcomes, a framework for the monitoring and evaluation of international surgical initiatives, the Framework for the Assessment of InteRNational Surgical Success (FAIRNeSS) is proposed. In response to the increasing number of surgical partnerships between developed and LMICs, we propose a framework to monitor and evaluate international surgical initiatives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montes-Rodríguez, María de los Ángeles, E-mail: angy24538@yahoo.com; Mitsoura, Eleni; Hernández-Bojórquez, Mariana
2014-11-07
Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as themore » isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.« less
Proceedings of the international workshop on monitoring forest degradation in Southeast Asia
Leif A. Mortenson; James J. Halperin; Patricia N. Manley; Rich L. Turner
2013-01-01
The international workshop on monitoring forest degradation in Southeast Asia provided a forum for discussion of the technical, social and political challenges and successes that have occurred during recent work in sub-national forest degradation monitoring. The 2012 workshop, held in Bangkok, Thailand, followed recent US Forest Service/LEAF (USAID's Lowering...
Monitoring of the Atmosphere on the International Space Station with the Air Quality Monitor
NASA Technical Reports Server (NTRS)
Wallace William T.; Limero, Thomas F.; Loh, Leslie J.; Mudgett, Paul D.; Gazda, Daniel B.
2017-01-01
During the early years of human spaceflight, short duration missions allowed for monitoring of the spacecraft environment to be performed via archival sampling, in which samples were returned to Earth for analysis. With the construction of the International Space Station (ISS) and the accompanying extended mission durations, the need for enhanced, real-time monitors became apparent. The Volatile Organic Analyzer (VOA) operated on ISS for 7 years, where it assessed trace volatile organic compounds in the cabin air. The large and fixed-position VOA was eventually replaced with the smaller Air Quality Monitor (AQM). Since March 2013, the atmosphere of the U.S. Operating Segment (USOS) has been monitored in near real-time by a pair of AQMs. These devices consist of a gas chromatograph (GC) coupled with a differential mobility spectrometer (DMS) and currently target detection list of 22 compounds. These targets are of importance to both crew health and the Environmental Control and Life Support Systems (ECLSS) on ISS. Data is collected autonomously every 73 hours, though the units can be controlled remotely from mission control to collect data more frequently during contingency or troubleshooting operations. Due to a nominal three-year lifetime on-orbit, the initial units were replaced in February 2016. This paper will focus on the preparation and use of the AQMs over the past several years. A description of the technical aspects of the AQM will be followed by lessons learned from the deployment and operation of the first set of AQMs. These lessons were used to improve the already-excellent performance of the instruments prior to deployment of the replacement units. Data trending over the past several years of operation on ISS will also be discussed, including data obtained during a survey of the USOS modules. Finally, a description of AQM use for contingency and investigative studies will be presented.
NASA Astrophysics Data System (ADS)
Detsis, Emmanouil; Brodsky, Yuval; Knudtson, Peter; Cuba, Manuel; Fuqua, Heidi; Szalai, Bianca
2012-11-01
Space assets have a unique opportunity to play a more active role in global resource management. There is a clear need to develop resource management tools in a global framework. Illegal, Unregulated and Unreported (IUU) fishing is placing pressure on the health and size of fishing stocks around the world. Earth observation systems can provide fishery management organizations with cost effective monitoring of large swaths of ocean. Project Catch is a fisheries management project based upon the complimentary, but independent Catch-VMS and Catch-GIS systems. Catch-VMS is a Vessel Monitoring System with increased fidelity over existing offerings. Catch-GIS is a Geographical Information System that combines VMS information with existing Earth Observation data and other data sources to identify Illegal, Unregulated and Unreported (IUU) fishing. Project Catch was undertaken by 19 Masters students from the 2010 class of the International Space University. In this paper, the space-based system architecture of Project Catch is presented and analyzed. The rationale for the creation of the system, as well as the engineering trade-off studies in its creation, are discussed. The Catch-VMS proposal was envisaged in order to address two specific problems: (1) the expansion of illegal fishing to high-latitude regions where existing satellite systems coverage is an issue and (2) the lack of coverage in remote oceanic regions due to reliance on coastal-based monitoring. Catch-VMS utilizes ship-borne transponders and hosted-payload receivers on a Global Navigation Satellite System in order to monitor the position and activity of compliant fishing vessels. Coverage is global and continuous with multiple satellites in view providing positional verification through multilateration techniques. The second part of the paper briefly describes the Catch-GIS system and investigates its cost of implementation.
Internal cycle modeling and environmental assessment of multiple cycle consumer products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsiliyannis, C.A., E-mail: anion@otenet.gr
2012-01-15
Highlights: Black-Right-Pointing-Pointer Dynamic flow models are presented for remanufactured, reused or recycled products. Black-Right-Pointing-Pointer Early loss and stochastic return are included for fast and slow cycling products. Black-Right-Pointing-Pointer The reuse-to-input flow ratio (Internal Cycle Factor, ICF) is determined. Black-Right-Pointing-Pointer The cycle rate, which is increasing with the ICF, monitors eco-performance. Black-Right-Pointing-Pointer Early internal cycle losses diminish the ICF, the cycle rate and performance. - Abstract: Dynamic annual flow models incorporating consumer discard and usage loss and featuring deterministic and stochastic end-of-cycle (EOC) return by the consumer are developed for reused or remanufactured products (multiple cycle products, MCPs), including fast andmore » slow cycling, short and long-lived products. It is shown that internal flows (reuse and overall consumption) increase proportionally to the dimensionless internal cycle factor (ICF) which is related to environmental impact reduction factors. The combined reuse/recycle (or cycle) rate is shown capable for shortcut, albeit effective, monitoring of environmental performance in terms of waste production, virgin material extraction and manufacturing impacts of all MCPs, a task, which physical variables (lifetime, cycling frequency, mean or total number of return trips) and conventional rates, via which environmental policy has been officially implemented (e.g. recycling rate) cannot accomplish. The cycle rate is shown to be an increasing (hyperbolic) function of ICF. The impact of the stochastic EOC return characteristics on total reuse and consumption flows, as well as on eco-performance, is assessed: symmetric EOC return has a small, positive effect on performance compared to deterministic, while early shifted EOC return is more beneficial. In order to be efficient, environmental policy should set higher minimum reuse targets for higher trippage MCPs. The results may serve for monitoring, flow accounting and comparative eco-assessment of MCPs. They may be useful in identifying reachable and efficient reuse/recycle targets for consumer products and in planning return via appropriate labelling and digital coding for enhancing environmental performance, while satisfying consumer demand.« less
Lung cancer mortality among workers at a nuclear materials fabrication plant.
Richardson, David B; Wing, Steve
2006-02-01
The Oak Ridge, Tennessee Y-12 plant has operated as a nuclear materials fabrication plant since the 1940s. Given the work environment, and prior findings that lung cancer mortality was elevated among white male Y-12 workers relative to US white males, we investigated whether lung cancer mortality was associated with occupational radiation exposures. A cohort of 3,864 workers hired between 1947 and 1974 who had been monitored for internal radiation exposure was identified. Vital status was ascertained through 1990. Over the study period 111 lung cancer deaths were observed. Cumulative external radiation dose under a 5-year lag assumption was positively associated with lung cancer mortality (0.54% increase in lung cancer mortality per 10 mSv, se=0.16, likelihood ratio test (LRT)=5.84, 1 degree of freedom [df]); cumulative internal radiation dose exhibited a highly-imprecise negative association with lung cancer mortality. The positive association between external radiation dose and lung cancer mortality was primarily due to exposure occurring in the period 5-14 years after exposure (0.97% increase in lung cancer mortality rate per 10 mSv, se=0.28, LRT=6.35, 1 df). The association between external radiation dose and lung cancer mortality was negative for exposures occurring at ages<35 years and positive for exposures occurring at ages 35-50 and 50+years. There is evidence of a positive association between cumulative external radiation dose and lung cancer mortality in this population. However, a causal interpretation of this association is constrained by the uncertainties in external and internal radiation dose estimates, the lack of information about exposures to other lung carcinogens, and the limited statistical power of the study. Copyright (c) 2005 Wiley-Liss, Inc.
Resident Perceptions of the Impact of Work Hour Limitations
Beck, David C.; Stewart, Anita L.; Garbutt, Jane M.
2007-01-01
BACKGROUND Mandatory work hour limitations for residents began in July 2003. There has been little evaluation of the impact of the new limitations on Internal Medicine residency training. OBJECTIVE To assess Internal Medicine residents’ perceptions of the impact of work hour limitations on clinical experiences, patient care, resident education, and well-being, and their compliance with the limitations. DESIGN AND PARTICIPANTS Cross-sectional survey administered to Internal Medicine residents at 1 large U.S. teaching hospital. MEASUREMENTS Resident perceptions using 5-point Likert scales, and self-reported compliance. Exploratory factor analysis was used to identify underlying domains and develop scales. RESULTS The survey response rate was 85%. Five domains were identified by factor analysis: 1) clinical experience, 2) patient care and safety, 3) communication, 4) satisfaction with training, and 5) work–rest balance. Residents perceived work hour limitations to have a negative impact on clinical experience (mean scale score 1.84, 1 = negative, 5 = positive), patient care and safety (2.64), and communication domains (1.98). Effects on satisfaction (3.12) and work–rest balance domains (2.95) were more positive. Senior residents perceived more negative effects of work hour limitations than interns. Compliance was difficult; 94% interns and 70% residents reported violating work hour limits. Patient care and teaching duties were the main reasons for work hour violations. CONCLUSIONS This study suggests that the current work hour limitations may be having unintended negative consequences on residency training. Ongoing monitoring to evaluate the impact of program changes as a result of work hour regulation is crucial to improving residency training. PMID:17468888
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-11
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-765] In the Matter of Certain Display Devices, Including Digital Televisions and Monitors II; Notice of Investigation AGENCY: U.S. International Trade... that a complaint was filed with the U.S. International Trade Commission on February 9, 2011, under...
Chou, Wen-Cheng; Shiao, Tsu-Hui; Shiao, Guang-Ming; Luo, Chin-Shan
2017-01-01
Overnight polysomnography (PSG) is currently the standard diagnostic procedure for obstructive sleep apnea (OSA). It has been known that monitoring of head position in sleep is crucial not only for the diagnosis (positional sleep apnea) but also for the management of OSA (positional therapy). However, there are no sensor systems available clinically to hook up with PSG for accurate head position monitoring. In this paper, an accelerometer-based sensing system for accurate head position monitoring is developed and realized. The core CORDIC- (COordinate Rotation DIgital Computer-) based tilting sensing algorithm is realized in the system to quickly and accurately convert accelerometer raw data into the desired head position tilting angles. The system can hook up with PSG devices for diagnosis to have head position information integrated with other PSG-monitored signals. It has been applied in an IRB test in Taipei Veterans General Hospital and has been proved that it can meet the medical needs of accurate head position monitoring for PSG diagnosis. PMID:29065608
Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor
2009-10-01
A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.
Steven C. Latta; C. John Ralph; Geoffrey R. Geupel
2005-01-01
Many international, regional, and local partner organizations have agreed in the need to establish long-term bird monitoring and research programs in the Americas. However, the challenge of developing national or international monitoring programs is difficult often because of the lack of qualified biologists or other resources in key regions. More fundamentally,...
Servat, A; Cliquet, F
2006-09-01
To prevent any introduction of rabies, many rabies-free countries have adopted a scheme requiring the rabies vaccination of pets associated with a serological test. FAVN test and RFFIT are the current OIE prescribed techniques to perform this assay. A qualitative indirect ELISA (Serelisa) test has been recently described as a screening test to monitor the effectiveness of rabies vaccination of pets. A lack of sensitivity requires ELISA negative samples to be retested using an OIE confirmatory test. This raised the question whether this new test could be reasonably proposed as an alternative tool in the context of international trades of pets. The Community Reference Institute of Nancy organized a short trial to answer this question. In this study, 16 laboratories tested a panel of their own samples with FAVN test/RFFIT and the Serelisa. The comparison of results revealed that the performance of the Serelisa is highly heterogeneous. A lack of sensitivity was detected in 50% of participants, when 25% of laboratories obtained a significant rate of false positive results. This last point questions the pertinence of using the Serelisa in the context of international trades by preventing any movements of insufficiently or non-protected animals.
Goldstein, R M; Engelhardt, H; Kamb, B; Frolich, R M
1993-12-03
Satellite radar interferometry (SRI) provides a sensitive means of monitoring the flow velocities and grounding-line positions of ice streams, which are indicators of response of the ice sheets to climatic change or internal instability. The detection limit is about 1.5 millimeters for vertical motions and about 4 millimeters for horizontal motions in the radar beam direction. The grounding line, detected by tidal motions where the ice goes afloat, can be mapped at a resolution of approximately 0.5 kilometer. The SRI velocities and grounding line of the Rutford Ice Stream, Antarctica, agree fairly well with earlier ground-based data. The combined use of SRI and other satellite methods is expected to provide data that will enhance the understanding of ice stream mechanics and help make possible the prediction of ice sheet behavior.
Post-Impact Fatigue Damage Monitoring Using Fiber Bragg Grating Sensors
Shin, Chow-Shing; Liaw, Shien-Kuei; Yang, Shi-Wei
2014-01-01
It has been shown that impact damage to composite materials can be revealed by embedded Fiber Bragg Gratings (FBG) as a broadening and splitting of the latter's characteristic narrow peak reflected spectrum. The current work further subjected the impact damaged composite to cyclic loading and found that the FBG spectrum gradually submerged into a rise of background intensity as internal damages progressed. By skipping the impact, directing the impact to positions away from the FBG and examining the extracted fibers, we concluded that the above change is not a result of deterioration/damage of the sensor. It is caused solely by the damages initiated in the composite by the impact and aggravated by fatigue loading. Evolution of the grating spectrum may therefore be used to monitor qualitatively the development of the incurred damages. PMID:24594609
Kurt Riitters; Christine Estreguil
2007-01-01
Presentations from the symposium "International Research to Monitor Sustainable Forest Spatial Patterns," which was organized as part of the International Union of Forest Research Organizations (IUFRO) World Congress in August 2005, are summarized in this report. The overall theme of the World Congress was "Forests in the Balance: Linking Tradition and...
Krause, David A; Dueffert, Lucas G; Postma, Jaclyn L; Vogler, Eric T; Walsh, Amy J; Hollman, John H
External rotation (ER) strengthening of the shoulder is an integral component of rehabilitative and preventative programs for overhead athletes. A variety of shoulder ER strengthening exercises are reported, including those intended to integrate the core musculature. The purpose of this study was to examine ER torque and electromyographic (EMG) activation of shoulder and trunk muscles while performing resisted isometric shoulder ER in 3 positions (standing, side lying, and side plank). Significantly greater force and shoulder muscle activation would be generated while side lying given the inherent stability of the position, and greater trunk muscle activation would be generated in the less stable plank position. Quasi-experimental repeated-measures study. Level 5. A convenience sample of 25 healthy overhead recreational athletes (9 men, 16 women) participated in this study. EMG electrodes were placed on the infraspinatus, posterior deltoid, middle trapezius, multifidi, internal obliques, and external obliques. EMG signals were normalized to a maximal isometric contraction. Participants performed resisted isometric ER in standing, side-lying, and side plank positions. Results were analyzed using a repeated-measures analysis of variance with post hoc Bonferroni corrections (α = 0.05). There was no significant difference in ER torque between positions (α = 0.05). A significant difference in EMG activity of shoulder and trunk musculature between positions was found in 7 of the 8 muscles monitored. Significantly greater EMG activity in the infraspinatus, middle trapezius, and the nondominant external and internal obliques was found in the side plank position as compared with standing and side lying. While there was no difference in ER torque between the 3 exercise positions, EMG activity of the shoulder and trunk muscles was dependent on body position. If a clinician is seeking to integrate trunk muscle activation while performing shoulder ER strengthening, the side plank position is preferred as compared with standing or side lying.
Gauvin, Hanna S; De Baene, Wouter; Brass, Marcel; Hartsuiker, Robert J
2016-02-01
To minimize the number of errors in speech, and thereby facilitate communication, speech is monitored before articulation. It is, however, unclear at which level during speech production monitoring takes place, and what mechanisms are used to detect and correct errors. The present study investigated whether internal verbal monitoring takes place through the speech perception system, as proposed by perception-based theories of speech monitoring, or whether mechanisms independent of perception are applied, as proposed by production-based theories of speech monitoring. With the use of fMRI during a tongue twister task we observed that error detection in internal speech during noise-masked overt speech production and error detection in speech perception both recruit the same neural network, which includes pre-supplementary motor area (pre-SMA), dorsal anterior cingulate cortex (dACC), anterior insula (AI), and inferior frontal gyrus (IFG). Although production and perception recruit similar areas, as proposed by perception-based accounts, we did not find activation in superior temporal areas (which are typically associated with speech perception) during internal speech monitoring in speech production as hypothesized by these accounts. On the contrary, results are highly compatible with a domain general approach to speech monitoring, by which internal speech monitoring takes place through detection of conflict between response options, which is subsequently resolved by a domain general executive center (e.g., the ACC). Copyright © 2015 Elsevier Inc. All rights reserved.
International Collaboration and Academic Exchange of the CHAIN Project in this Three Years (Period)
NASA Astrophysics Data System (ADS)
Ueno, Satoru; Shibata, Kazunari; Morita, Satoshi; Kimura, Goichi; Asai, Ayumi; Kitai, Reizaburo; Ichimoto, Kiyoshi; Nagata, Shin'ichi; Ishii, Takako; Nakatani, Yoshikazu; Masashi, Yamaguchi; et al.
2014-02-01
We will introduce contents of international collaboration and academic exchange of the CHAIN project in recent three years (ISWI period). After April of 2010, we have not obtained any enough budget for new instruments. Therefore, we have not been able to install new Flare Monitoring Telescopes (FMT) in new countries, such as Algeria. On the other hand, however, we have continued international academic exchange through scientific and educational collaboration with mainly Peru, such as data-analysis training, holding scientific workshops etc. Additionally, in this year, King Saudi University of Saudi Arabia and CRAAG of Algeria have planned to build a new FMT in their university by their own budget. Therefore, we have started some collaboration in the field of technical advices of instruments and scientific themes etc. Moreover, Pakistan Space and Upper Atmosphere Research Commission (SUPARCO) also offered us participation in the CHAIN-project. We would like to continue to consider the possibility of academic collaboration with such new positive developing nations, too.
Cho, Byungchul; Poulsen, Per; Ruan, Dan; Sawant, Amit; Keall, Paul J
2012-11-21
The goal of this work was to experimentally quantify the geometric accuracy of a novel real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring for clinically realistic arc and static field treatment delivery and target motion conditions. A general method for real-time target localization using kV imaging and respiratory monitoring was developed. Each dimension of internal target motion T(x, y, z; t) was estimated from the external respiratory signal R(t) through the correlation between R(t(i)) and the projected marker positions p(x(p), y(p); t(i)) on kV images by a state-augmented linear model: T(x, y, z; t) = aR(t) + bR(t - τ) + c. The model parameters, a, b, c, were determined by minimizing the squared fitting error ∑‖p(x(p), y(p); t(i)) - P(θ(i)) · (aR(t(i)) + bR(t(i) - τ) + c)‖(2) with the projection operator P(θ(i)). The model parameters were first initialized based on acquired kV arc images prior to MV beam delivery. This method was implemented on a trilogy linear accelerator consisting of an OBI x-ray imager (operating at 1 Hz) and real-time position monitoring (RPM) system (30 Hz). Arc and static field plans were delivered to a moving phantom programmed with measured lung tumour motion from ten patients. During delivery, the localization method determined the target position and the beam was adjusted in real time via dynamic multileaf collimator (DMLC) adaptation. The beam-target alignment error was quantified by segmenting the beam aperture and a phantom-embedded fiducial marker on MV images and analysing their relative position. With the localization method, the root-mean-squared errors of the ten lung tumour traces ranged from 0.7-1.3 mm and 0.8-1.4 mm during the single arc and five-field static beam delivery, respectively. Without the localization method, these errors ranged from 3.1-7.3 mm. In summary, a general method for real-time target localization using kV imaging and respiratory monitoring has been experimentally investigated for arc and static field delivery. The average beam-target error was 1 mm.
NASA Astrophysics Data System (ADS)
Cho, Byungchul; Poulsen, Per; Ruan, Dan; Sawant, Amit; Keall, Paul J.
2012-11-01
The goal of this work was to experimentally quantify the geometric accuracy of a novel real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring for clinically realistic arc and static field treatment delivery and target motion conditions. A general method for real-time target localization using kV imaging and respiratory monitoring was developed. Each dimension of internal target motion T(x, y, z; t) was estimated from the external respiratory signal R(t) through the correlation between R(ti) and the projected marker positions p(xp, yp; ti) on kV images by a state-augmented linear model: T(x, y, z; t) = aR(t) + bR(t - τ) + c. The model parameters, a, b, c, were determined by minimizing the squared fitting error ∑‖p(xp, yp; ti) - P(θi) · (aR(ti) + bR(ti - τ) + c)‖2 with the projection operator P(θi). The model parameters were first initialized based on acquired kV arc images prior to MV beam delivery. This method was implemented on a trilogy linear accelerator consisting of an OBI x-ray imager (operating at 1 Hz) and real-time position monitoring (RPM) system (30 Hz). Arc and static field plans were delivered to a moving phantom programmed with measured lung tumour motion from ten patients. During delivery, the localization method determined the target position and the beam was adjusted in real time via dynamic multileaf collimator (DMLC) adaptation. The beam-target alignment error was quantified by segmenting the beam aperture and a phantom-embedded fiducial marker on MV images and analysing their relative position. With the localization method, the root-mean-squared errors of the ten lung tumour traces ranged from 0.7-1.3 mm and 0.8-1.4 mm during the single arc and five-field static beam delivery, respectively. Without the localization method, these errors ranged from 3.1-7.3 mm. In summary, a general method for real-time target localization using kV imaging and respiratory monitoring has been experimentally investigated for arc and static field delivery. The average beam-target error was 1 mm.
EDITORIAL: Sensors and sensing systems
NASA Astrophysics Data System (ADS)
Dewhurst, Richard; Tian, Gui Yun
2008-02-01
Sensors are very important for measurement science and technology. They serve as a vital component in new measurement techniques and instrumentation systems. Key qualities of a good sensor system are high resolution, high reliability, low cost, appropriate output for a given input (good sensitivity), rapid response time, small random error in results, and small systematic error. Linearity is also useful, but with the advent of lookup tables and software, it is not as important as it used to be. In the last several years, considerable effort around the world has been devoted to a wide range of sensors from nanoscale sensors to sensor networks. Collectively, these vast and multidisciplinary efforts are developing important technological roadmaps to futuristic sensors with new modalities, significantly enhanced effectiveness and integrated functionality (data processing, computation, decision making and communications). When properly organized, they will have important relevance to life science and security applications, e.g. the sensing and monitoring of chemical, biological, radiological and explosive threats. A special feature in this issue takes a snapshot of some recent developments that were first presented at an international conference, the 2007 IEEE International Conference on Networking, Sensing and Control (ICNSC). The conference discussed recent developments, from which a few papers have since been brought together in this special feature. Gas sensing for environmental monitoring remains a topical subject, and two papers deal with this issue. One is concerned with the exploitation of nanostructured Au-doped cobalt oxyhydroxide-based carbon monoxide sensors for fire detection at its earlier stages (Zhuiykov and Dowling), whilst another examines the role of oxygen in high temperature hydrogen sulfide detection using MISiC sensors (Weng et al). Again for environmental monitoring, another paper deals with accurate sound source localization in a reverberant environment using multiple acoustic sensors (Atmoko et al). Not only is gaseous monitoring important, there are particular difficulties when it comes to the continuous monitoring of solids by non-destructive evaluation techniques. Examples of potential solutions for specialist applications are sensors for the detection and measurement of thin dielectric layers using reflection of frequency-scanned millimetre electromagnetic waves (Bowring et al), and an electrostatic sensor for velocity measurements of pneumatically conveyed solid particles (Xu et al). For potential medical applications, position measurement of internal organs is an on-going challenge. Tracking of internal organ motion with a six degree-of-freedom MEMS sensor is discussed by Bandala and Joyce. We hope that these papers provide an insight into exciting developments that continue to take place in the field of sensors and control.
The Use of Remote Sensing Satellites for Verification in International Law
NASA Astrophysics Data System (ADS)
Hettling, J. K.
The contribution is a very sensitive topic which is currently about to gain significance and importance in the international community. It implies questions of international law as well as the contemplation of new developments and decisions in international politics. The paper will begin with the meaning and current status of verification in international law as well as the legal basis of satellite remote sensing in international treaties and resolutions. For the verification part, this implies giving a definition of verification and naming its fields of application and the different means of verification. For the remote sensing part, it involves the identification of relevant provisions in the Outer Space Treaty and the United Nations General Assembly Principles on Remote Sensing. Furthermore it shall be looked at practical examples: in how far have remote sensing satellites been used to verify international obligations? Are there treaties which would considerably profit from the use of remote sensing satellites? In this respect, there are various examples which can be contemplated, such as the ABM Treaty (even though out of force now), the SALT and START Agreements, the Chemical Weapons Convention and the Conventional Test Ban Treaty. It will be mentioned also that NGOs have started to verify international conventions, e.g. Landmine Monitor is verifying the Mine-Ban Convention. Apart from verifying arms control and disarmament treaties, satellites can also strengthen the negotiation of peace agreements (such as the Dayton Peace Talks) and the prevention of international conflicts from arising. Verification has played an increasingly prominent role in high-profile UN operations. Verification and monitoring can be applied to the whole range of elements that constitute a peace implementation process, ranging from the military aspects through electoral monitoring and human rights monitoring, from negotiating an accord to finally monitoring it. Last but not least the problem of enforcing international obligations needs to be addressed, especially the dependence of international law on the will of political leaders and their respective national interests.
Global Monitoring of Water Supply and Sanitation: History, Methods and Future Challenges
Bartram, Jamie; Brocklehurst, Clarissa; Fisher, Michael B.; Luyendijk, Rolf; Hossain, Rifat; Wardlaw, Tessa; Gordon, Bruce
2014-01-01
International monitoring of drinking water and sanitation shapes awareness of countries’ needs and informs policy, implementation and research efforts to extend and improve services. The Millennium Development Goals established global targets for drinking water and sanitation access; progress towards these targets, facilitated by international monitoring, has contributed to reducing the global disease burden and increasing quality of life. The experiences of the MDG period generated important lessons about the strengths and limitations of current approaches to defining and monitoring access to drinking water and sanitation. The methods by which the Joint Monitoring Programme (JMP) of WHO and UNICEF tracks access and progress are based on analysis of data from household surveys and linear regression modelling of these results over time. These methods provide nationally-representative and internationally-comparable insights into the drinking water and sanitation facilities used by populations worldwide, but also have substantial limitations: current methods do not address water quality, equity of access, or extra-household services. Improved statistical methods are needed to better model temporal trends. This article describes and critically reviews JMP methods in detail for the first time. It also explores the impact of, and future directions for, international monitoring of drinking water and sanitation. PMID:25116635
System and method for engine combustion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sczomak, David P.; Gallon, Robert J.; Solomon, Arun S.
A combustion system for use with one or more cylinder bores of an internal combustion engine includes at least one cylinder head defining first and second intake ports in fluid communication with the one or more cylinder bores. A flap is adjustably connected to the at least one cylinder head. The flap includes a first flap portion cooperating with the first intake port extending from an arm and a second flap portion cooperating with the second intake port extending from the arm and disposed adjacent the first flap portion. A controller in electrical communication with an actuator monitors the conditionmore » of the engine and actuates the flap to position the first and second flap portions between first and second positions to create a first combustion condition and a second combustion condition.« less
Holmes, Avram J; Pizzagalli, Diego A
2007-02-01
Emerging evidence suggests that depression is associated with executive dysfunction, particularly after committing errors or receiving negative performance feedback. To test this hypothesis, 57 participants performed two executive tasks known to elicit errors (the Simon and Stroop Tasks) during positive or negative performance feedback. Participants with elevated depressive symptoms (Beck Depression Inventory scores >or= 13) were characterized by impaired posterror and postconflict performance adjustments, especially during emotionally negative task-related feedback. Additionally, for both tasks, depressive symptoms were inversely related to postconflict reaction time adjustments following negative, but not positive, feedback. These findings suggest that subclinical depression is associated with impairments in behavioral adjustments after internal (perceived failure) and external feedback about deficient task performance. (c) 2007 APA, all rights reserved.
Uribe, Alberto A; Mendel, Ehud; Peters, Zoe A; Shneker, Bassel F; Abdel-Rasoul, Mahmoud; Bergese, Sergio D
2017-10-01
To determine the comparison of its clinical utility and safety profile for visual evoked potential (VEP) monitoring during prone spine surgeries under total intravenous anesthesia (TIVA) versus balanced general anesthesia using the SightSaver™ visual stimulator. The protocol was designed asa pilot, single center, prospective, randomized, and double-arm study. Subjects were randomized to receive either TIVA or balanced general anesthesia. Following induction and intubation, 8 electrodes were placed subcutaneously to collect VEP recordings. The SightSaver™ visual stimulator was placed on the subject's scalp before prone positioning. VEP waveforms were recorded every 30min and assessed by a neurophysiologist throughout the length of surgery. A total of 19 subjects were evaluated and VEP waveforms were successfully collected. TIVA group showed higher amplitude and lower latency than balanced anesthesia. Our data suggested that TIVA is associated with higher VEP amplitude and shorter latencies than balanced general anesthesia; therefore, TIVA could be the most efficient anesthesia regimen for VEP monitoring. The findings help to better understand the effect of different anesthesia regimens on intra-operative VEP monitoring. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Meier, Benjamin Mason; De Milliano, Marlous; Chakrabarti, Averi; Kim, Yuna
2017-11-04
Employing novel coding methods to evaluate human rights monitoring, this article examines the influence of United Nations (UN) treaty bodies on national implementation of the human right to health. The advancement of the right to health in the UN human rights system has shifted over the past 20 years from the development of norms under international law to the implementation of those norms through national policy. Facilitating accountability for this rights-based policy implementation under the right to health, the UN Committee on Economic, Social and Cultural Rights (CESCR) monitors state implementation by reviewing periodic reports from state parties, engaging in formal sessions of 'constructive dialogue' with state representatives, and issuing concluding observations for state response. These concluding observations recognise the positive steps taken by states and highlight the principal areas of CESCR concern, providing recommendations for implementing human rights and detailing issues to be addressed in the next state report. Through analytic coding of the normative indicators of the right to health in both state reports and concluding observations, this article provides an empirical basis to understand the policy effects of the CESCR monitoring process on state implementation of the right to health.
Hanford Internal Dosimetry Project manual. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.
1994-07-01
This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, andmore » guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program.« less
A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study.
Schoot, Tessa S; Weenk, Mariska; van de Belt, Tom H; Engelen, Lucien J L P G; van Goor, Harry; Bredie, Sebastian J H
2016-05-05
Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP self-measurement. The objective of our study was to evaluate the performance of the first release of the Checkme Health Monitor (Viatom Technology), a cuffless BP monitor, in a real-life setting. Furthermore, we wanted to investigate whether the posture of the volunteer and the position of the device relative to the heart level would influence its outcomes. Study volunteers fell into 3 BP ranges: high (>160 mmHg), normal (130-160 mmHg), and low (<130 mmHg). All requirements for test environment, observer qualification, volunteer recruitment, and BP measurements were met according to the European Society of Hypertension International Protocol (ESH-IP) for the validation of BP measurement devices. After calibrating the Checkme device, we measured systolic BP with Checkme and a validated, oscillometric reference BP monitor (RM). Measurements were performed in randomized order both in supine and in sitting position, and with Checkme at and above heart level. We recruited 52 volunteers, of whom we excluded 15 (12 due to calibration failure with Checkme, 3 due to a variety of reasons). The remaining 37 volunteers were divided into low (n=14), medium (n=13), and high (n=10) BP ranges. There were 18 men and 19 women, with a mean age of 54.1 (SD 14.5) years, and mean recruitment systolic BP of 141.7 (SD 24.7) mmHg. BP results obtained by RM and Checkme correlated well. In the supine position, the difference between the RM and Checkme was >5 mmHg in 17 of 37 volunteers (46%), of whom 9 of 37 (24%) had a difference >10 mmHg and 5 of 37 (14%) had a difference >15 mmHg. BP obtained with Checkme correlated well with RM BP, particularly in the position (supine) in which the device was calibrated. These preliminary results are promising for conducting further research on cuffless BP measurement in the clinical and outpatient settings.
Using Telescopic Observations to Mentor High School Students in STEM
NASA Astrophysics Data System (ADS)
McLin, Kevin M.; Cominsky, Lynn R.
2011-03-01
Over the past two summers (2009/2010) the NASA E/PO Group at Sonoma State University has sponsored local high school students in a summer science internship program at the University. The students, chosen from Sonoma County high schools in a competitive selection process, work in various STEM fields throughout the School of Science and Technology at SSU. The two interns sponsored by the E/PO Group each summer use GORT, the NASA/Fermi-sponsored robotic observatory operated by the Group, to monitor active galaxies. They are mentored in their projects by E/PO Group personnel and by SSU undergraduates who have experience with the telescope. The students learn about the sky, telescopes and the active galaxies they observe. They also learn how to make telescopic observations and how to reduce the CCD images obtained. Interns also participate in weekly meetings with other interns working on different projects around campus. At the end of the summer all the interns present their research results at a symposium held on campus.The symposium is attended by the interns themselves, their parents and sponsoring high school science teachers, and university faculty and administrators.The program has had a positive impact on how our interns view science, as reported by themselves, and specifically on their view of astronomy, in the first year of the program.
Life satisfaction and maladaptive behaviors in early adolescents.
Lyons, Michael D; Otis, Kristin L; Huebner, E Scott; Hills, Kimberly J
2014-12-01
This study explored the directionality of the relations between global life satisfaction (LS) and internalizing and externalizing behaviors using a sample of regular education students who were initially enrolled in Grade 7 (n = 470). Self-report measures of internalizing and externalizing behaviors and LS were administered on 2 occasions, 6 months apart, to students from a Southeastern U.S. middle school. Short-term longitudinal analyses revealed that neither externalizing behaviors nor internalizing behaviors at Time 1 predicted LS at Time 2. However, LS at Time 1 predicted externalizing behaviors at Time 2. LS at Time 1 also predicted internalizing behaviors at Time 2, but the results were moderated by student gender. At higher levels of LS, boys reported lower levels of internalizing behaviors at Time 2. The overall results suggested that lower levels of LS are an antecedent of increased maladaptive behaviors among early adolescents. Alternatively, higher levels of LS may be a protective factor against subsequent externalizing behaviors among boys and girls and internalizing behaviors among boys. Furthermore, the results provide further support for the discriminant validity of positive and negative measures of mental health and suggest that LS measures may provide useful information for comprehensive adolescent health screening and monitoring systems. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Physical Demands of Women's Rugby Sevens Matches: Female Athletes in Motion (FAiM) Study.
Vescovi, J D; Goodale, T
2015-11-01
This cross-sectional study characterized the locomotor, heart rate and metabolic power characteristics of women's rugby sevens matches. 4 Canadian teams were monitored during the USA Rugby Sevens event using global positioning system technology with players classified as International (n=16) or Developmental (n=13). Dependent variables were compared between these 2 groups using an ANOVA with duration played as a covariate. International players covered greater distances (1 468±88 m) than Developmental (1 252±135 m); mostly from more high-intensity (224±55 m vs. 131±44 m) and sprint distances (128±67 m vs. 57±44 m). International players also had more distance in high (264±36 m vs. 210±54 m), elevated (118±17 m vs. 76±20 m) and maximal (69±17 m vs. 30 ± 15 m) metabolic power categories. Time in various heart rate zones was similar between standards; however peak (187±6 bpm vs. 194±5 bpm) and mean (172±7 bpm vs. 180±9 bpm) heart rate values were lower for International players. International players had greater fitness scores (YoYo IRT1-1 160±191 m vs. 781±129 m) and maximal sprint speed (27.3±0.7 vs. 26.0±1.5 km·h(-1)). The current findings highlight developmental gaps in match demands between standards and show that field-based fitness tests discriminate among levels of play. The external and internal loads should be used by sport organizations to assist in forming appropriate training plans and utilize the performance tests to help monitor player development. © Georg Thieme Verlag KG Stuttgart · New York.
ERIC Educational Resources Information Center
Colombani, Olivier; Langelier, Ophelie; Martwong, Ekkachai; Castignolles, Patrice
2011-01-01
The use of an internal standard is a conventional and convenient way to monitor the conversion of one or several monomers during a controlled radical polymerization. However, the validity of this technique relies on an accurate determination of the initial monomer-to-internal standard ratio, A[subscript 0], because all subsequent calculations of…
Code of Federal Regulations, 2010 CFR
2010-07-01
... I am an owner or operator of an emergency stationary SI internal combustion engine? 60.4237 Section... Internal Combustion Engines Other Requirements for Owners and Operators § 60.4237 What are the monitoring requirements if I am an owner or operator of an emergency stationary SI internal combustion engine? (a...
Code of Federal Regulations, 2012 CFR
2012-07-01
... I am an owner or operator of an emergency stationary SI internal combustion engine? 60.4237 Section... Internal Combustion Engines Other Requirements for Owners and Operators § 60.4237 What are the monitoring requirements if I am an owner or operator of an emergency stationary SI internal combustion engine? (a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... I am an owner or operator of an emergency stationary SI internal combustion engine? 60.4237 Section... Internal Combustion Engines Other Requirements for Owners and Operators § 60.4237 What are the monitoring requirements if I am an owner or operator of an emergency stationary SI internal combustion engine? (a...
Code of Federal Regulations, 2014 CFR
2014-07-01
... I am an owner or operator of an emergency stationary SI internal combustion engine? 60.4237 Section... Internal Combustion Engines Other Requirements for Owners and Operators § 60.4237 What are the monitoring requirements if I am an owner or operator of an emergency stationary SI internal combustion engine? (a...
Code of Federal Regulations, 2011 CFR
2011-07-01
... I am an owner or operator of an emergency stationary SI internal combustion engine? 60.4237 Section... Internal Combustion Engines Other Requirements for Owners and Operators § 60.4237 What are the monitoring requirements if I am an owner or operator of an emergency stationary SI internal combustion engine? (a...
NASA Astrophysics Data System (ADS)
Stuffler, Timo; Graue, Roland; Bird, Antony J.; Dean, Antony; Staubert, Rüdiger
2018-04-01
This paper, "PIMACS (Polarimeter and improved modular anti-coincidence system): an effective instrument concept for x-, gamma-ray monitoring, and polarimetry measurements on the International Space Station," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.
Balloon-borne air traffic management (ATM) as a precursor to space-based ATM
NASA Astrophysics Data System (ADS)
Brodsky, Yuval; Rieber, Richard; Nordheim, Tom
2012-01-01
The International Space University—Balloon Air traffic control Technology Experiment (I-BATE ) has flown on board two stratospheric balloons and has tracked nearby aircraft by receiving their Automatic Dependent Surveillance-Broadcast (ADS-B) transmissions. Air traffic worldwide is facing increasing congestion. It is predicted that daily European flight volumes will more than double by 2030 compared to 2009 volumes. ADS-B is an air traffic management system being used to mitigate air traffic congestion. Each aircraft is equipped with both a GPS receiver and an ADS-B transponder. The transponder transmits an equipped aircraft's unique identifier, position, heading, and velocity once per second. The ADS-B transmissions can then be received by ground stations for use in traditional air traffic management. Airspace not monitored by these ground stations or other traditional means remains uncontrolled and poorly monitored. A constellation of space-based ADS-B receivers could close these gaps and provide global air traffic monitoring. By flying an ADS-B receiver on a stratospheric balloon, I-BATE has served as a precursor to a constellation of ADS-B-equipped Earth-orbiting satellites. From the ˜30 km balloon altitude, I-BATE tracked aircraft ranging up to 850 km. The experiment has served as a proof of concept for space-based air traffic management and supports a technology readiness level 6 of space-based ADS-B reception. I-BATE: International Space University—Balloon Air traffic control Technology Experiment.
NASA Technical Reports Server (NTRS)
James, John T.; Zalesak, Selina M.
2011-01-01
The primary reason for monitoring air quality aboard the International Space Station (ISS) is to determine whether air pollutants have collectively reached a concentration where the crew could experience adverse health effects. These effects could be near-real-time (e.g. headache, respiratory irritation) or occur late in the mission or even years later (e.g. cancer, liver toxicity). Secondary purposes for monitoring include discovery that a potentially harmful compound has leaked into the atmosphere or that air revitalization system performance has diminished. Typical ISS atmospheric trace pollutants consist of alcohols, aldehydes, aromatic compounds, halo-carbons, siloxanes, and silanols. Rarely, sulfur-containing compounds and alkanes are found at trace levels. Spacecraft Maximum Allowable Concentrations (SMACs) have been set in cooperation with a subcommittee of the National Research Council Committee on Toxicology. For each compound and time of exposure, the limiting adverse effect(s) has been identified. By factoring the analytical data from the Air Quality Monitor (AQM), which is in use as a prototype instrument aboard the ISS, through the array of compounds and SMACs, the risk of 16 specific adverse effects can be estimated. Within each adverse-effect group, we have used an additive model proportioned to each applicable 180-day SMAC to estimate risk. In the recent past this conversion has been performed using archival data, which can be delayed for months after an air sample is taken because it must be returned to earth for analysis. But with the AQM gathering in situ data each week, NASA is in a position to follow toxic-effect groups and correlate these with any reported crew symptoms. The AQM data are supplemented with data from real-time CO2 instruments aboard the ISS and from archival measurements of formaldehyde, which the AQM cannot detect.
500 MHz narrowband beam position monitor electronics for electron synchrotrons
NASA Astrophysics Data System (ADS)
Mohos, I.; Dietrich, J.
1998-12-01
Narrowband beam position monitor electronics were developed in the Forschungszentrum Jülich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network.
Progress on the CWU READI Analysis Center
NASA Astrophysics Data System (ADS)
Melbourne, T. I.; Szeliga, W. M.; Santillan, V. M.; Scrivner, C.
2015-12-01
Real-time GPS position streams are desirable for a variety of seismic monitoring and hazard mitigation applications. We report on progress in our development of a comprehensive real-time GPS-based seismic monitoring system for the Cascadia subduction zone. This system is based on 1 Hz point position estimates computed in the ITRF08 reference frame. Convergence from phase and range observables to point position estimates is accelerated using a Kalman filter based, on-line stream editor that produces independent estimations of carrier phase integer biases and other parameters. Positions are then estimated using a short-arc approach and algorithms from JPL's GIPSY-OASIS software with satellite clock and orbit products from the International GNSS Service (IGS). The resulting positions show typical RMS scatter of 2.5 cm in the horizontal and 5 cm in the vertical with latencies below 2 seconds. To facilitate the use of these point position streams for applications such as seismic monitoring, we broadcast real-time positions and covariances using custom-built aggregation-distribution software based on RabbitMQ messaging platform. This software is capable of buffering 24-hour streams for hundreds of stations and providing them through a REST-ful web interface. To demonstrate the power of this approach, we have developed a Java-based front-end that provides a real-time visual display of time-series, displacement vector fields, and map-view, contoured, peak ground displacement. This Java-based front-end is available for download through the PANGA website. We are currently analyzing 80 PBO and PANGA stations along the Cascadia margin and gearing up to process all 400+ real-time stations that are operating in the Pacific Northwest, many of which are currently telemetered in real-time to CWU. These will serve as milestones towards our over-arching goal of extending our processing to include all of the available real-time streams from the Pacific rim. In addition, we have developed a Kalman filter to combine CWU real-time PPP solutions with those from Scripps Institute of Oceanography's PPP-AR real-time solutions as well as real-time solutions from the USGS. These combined products should improve the robustness and reliability of real-time point-position streams in the near future.
Cordella, Roberto; Acerbi, Francesco; Broggi, Morgan; Vailati, Davide; Nazzi, Vittoria; Schiariti, Marco; Tringali, Giovanni; Ferroli, Paolo; Franzini, Angelo; Broggi, Giovanni
2013-06-01
To evaluate the role of intraoperative neurophysiological monitoring in image-guided mini-invasive neurosurgery. Twenty-one patients were operated under general anaesthesia with the aid of multimodal intraoperative neurophysiological monitoring to remove supratentorials tumors closely related to the cortico-spinal tract. Pre-operative assessment included fMRI scans and tractography that were uploaded into the intraoperative neuro-navigation system. Monitoring consisted in simultaneously recording EEG, electrocorticography, transcranial and direct motor evoked potentials (tMEP and dMEP), somatosensory evoked potentials and subcortical stimulation during the whole procedures. The recording of all the electrophysiological signals was possible in all procedures. SSEP guided the positioning of the strip electrode over the motor cortex (N20 phase inversion) that was used to evoke dMEP and monitor the lower limb motor responses; subcortical stimulation to unveil the spatial relationship between the tumors and motor fibers. Four patients had transient worsening of the symptoms, but only two had a long-term worsening, although not severe, of the pre-op clinical status. Intraoperative neurophysiology has a great value in mini-invasive neurosurgery, especially because the motor cortex is not exposed, consequently it cannot be directly mapped. This report describes a valuable scheme making use of as many electrophysiological signals as possible to constantly monitor the motor functions. A useful method to monitor motor functions in mini-invasive neurosurgery was described. Copyright © 2012 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Source Monitoring in Alzheimer's Disease
ERIC Educational Resources Information Center
El Haj, Mohamad; Fasotti, Luciano; Allain, Philippe
2012-01-01
Source monitoring is the process of making judgments about the origin of memories. There are three categories of source monitoring: reality monitoring (discrimination between self- versus other-generated sources), external monitoring (discrimination between several external sources), and internal monitoring (discrimination between two types of…
Eisler, Diane L.; McNabb, Alan; Jorgensen, Danielle R.; Isaac-Renton, Judith L.
2004-01-01
We report on the use of West Nile virus Armored RNA as an internal positive control (IPC) for the extraction and reverse transcription-PCR (RT-PCR) of RNA extracted from field-collected mosquitoes and on a multiplex real-time Taqman RT-PCR to simultaneously detect the 3′ noncoding region of West Nile virus and the West Nile virus NS5-2 region comprising the IPC. Mosquito pools from the province of British Columbia, Canada (n = 635), were tested in duplicate and found to be negative for West Nile virus and positive for the IPC. Known West Nile virus-positive supernatants from mosquito pools from the provinces of Alberta and Manitoba were tested in duplicate and found to be positive for both regions of the West Nile virus genome. The mean cycle threshold (Ct) value for the IPC in batch extraction controls ± 2 standard deviations was found to be 36.43 ± 1.78 cycles. IPCs of 98.4% (624) of West Nile virus-negative pools fell within this range, indicating the reproducibility of RNA extraction and RT-PCR for pools varying in mosquito genus and number. A comparison of mosquito pool genera revealed no significant genus effect on the Ct value of the IPC. The incorporation of West Nile virus Armored RNA as an IPC allows monitoring of RNA extraction and RT-PCR and detection of false-negative results due to failures in these processes or to PCR inhibition, respectively. PMID:14766868
Nomura, Shuhei; Tsubokura, Masaharu; Ozaki, Akihiko; Murakami, Michio; Hodgson, Susan; Blangiardo, Marta; Nishikawa, Yoshitaka; Morita, Tomohiro; Oikawa, Tomoyoshi
2017-04-09
Following Japan's 2011 Fukushima nuclear incident, we assessed voluntary-based monitoring behavior in Minamisoma City-located 10-40 km from the Fukushima nuclear plant-to inform future monitoring strategies. The monitoring in Minamisoma included occasional free of charge internal-radiation-exposure measurements. Out of around 70,000 individuals residing in the city before the incident, a total of 45,788 residents (female: 52.1%) aged ≥21 were evaluated. The monitoring prevalence in 2011-2012 was only 30.2%, and this decreased to 17.9% in 2013-2014. Regression analyses were performed to estimate factors associated with the monitoring prevalence and participation behavior. The results show that, in comparison with the age cohort of 21-30 years, the cohort of 71-80 and ≥81 years demonstrated significantly lower monitoring prevalence; female residents had higher monitoring prevalence than male residents; those who were living in evacuation zones at the time of the incident had higher monitoring prevalence than those who lived outside any of the evacuation zones; for those living outside Fukushima and neighboring Prefectures post-incident monitoring prevalence decreased significantly in 2013-2014. Our findings inform the discussion on the concepts of radiation risk perception and accessibility to monitoring and societal decision-making regarding the maintenance of the monitoring program with low monitoring prevalence. We also stress the possibility that the monitoring can work both to check that internal contamination levels are within acceptable limits, and as a risk communication tool, alleviating individuals' concern and anxiety over radiation contamination.
Manoiloff, Laura; Segui, Juan; Hallé, Pierre
2016-01-01
In this research, we combine a cross-form word-picture visual masked priming procedure with an internal phoneme monitoring task to examine repetition priming effects. In this paradigm, participants have to respond to pictures whose names begin with a prespecified target phoneme. This task unambiguously requires retrieving the word-form of the target picture's name and implicitly orients participants' attention towards a phonological level of representation. The experiments were conducted within Spanish, whose highly transparent orthography presumably promotes fast and automatic phonological recoding of subliminal, masked visual word primes. Experiments 1 and 2 show that repetition primes speed up internal phoneme monitoring in the target, compared to primes beginning with a different phoneme from the target, or sharing only their first phoneme with the target. This suggests that repetition primes preactivate the phonological code of the entire target picture's name, hereby speeding up internal monitoring, which is necessarily based on such a code. To further qualify the nature of the phonological code underlying internal phoneme monitoring, a concurrent articulation task was used in Experiment 3. This task did not affect the repetition priming effect. We propose that internal phoneme monitoring is based on an abstract phonological code, prior to its translation into articulation.
Form Overrides Meaning When Bilinguals Monitor for Errors
Ivanova, Iva; Ferreira, Victor S.; Gollan, Tamar H.
2016-01-01
Bilinguals rarely produce unintended language switches, which may in part be because switches are detected and corrected by an internal monitor. But are language switches easier or harder to detect than within-language semantic errors? To approximate internal monitoring, bilinguals listened (Experiment 1) or read aloud (Experiment 2) stories, and detected language switches (translation equivalents or semantically unrelated to expected words) and within-language errors (semantically related or unrelated to expected words). Bilinguals detected semantically related within-language errors most slowly and least accurately, language switches more quickly and accurately than within-language errors, and (in Experiment 2), translation equivalents as quickly and accurately as unrelated language switches. These results suggest that internal monitoring of form (which can detect mismatches in language membership) completes earlier than, and is independent of, monitoring of meaning. However, analysis of reading times prior to error detection revealed meaning violations to be more disruptive for processing than language violations. PMID:28649169
GEOGLAM Crop Monitor Assessment Tool: Developing Monthly Crop Condition Assessments
NASA Astrophysics Data System (ADS)
McGaughey, K.; Becker Reshef, I.; Barker, B.; Humber, M. L.; Nordling, J.; Justice, C. O.; Deshayes, M.
2014-12-01
The Group on Earth Observations (GEO) developed the Global Agricultural Monitoring initiative (GEOGLAM) to improve existing agricultural information through a network of international partnerships, data sharing, and operational research. This presentation will discuss the Crop Monitor component of GEOGLAM, which provides the Agricultural Market Information System (AMIS) with an international, multi-source, and transparent consensus assessment of crop growing conditions, status, and agro-climatic conditions likely to impact global production. This activity covers the four primary crop types (wheat, maize, rice, and soybean) within the main agricultural producing regions of the AMIS countries. These assessments have been produced operationally since September 2013 and are published in the AMIS Market Monitor Bulletin. The Crop Monitor reports provide cartographic and textual summaries of crop conditions as of the 28th of each month, according to crop type. This presentation will focus on the building of international networks, data collection, and data dissemination.
Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin
2016-09-01
Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).
An Embedded Stress Sensor for Concrete SHM Based on Amorphous Ferromagnetic Microwires
Olivera, Jesús; González, Margarita; Fuente, José Vicente; Varga, Rastislav; Zhukov, Arkady; Anaya, José Javier
2014-01-01
A new smart concrete aggregate design as a candidate for applications in structural health monitoring (SHM) of critical elements in civil infrastructure is proposed. The cement-based stress/strain sensor was developed by utilizing the stress/strain sensing properties of a magnetic microwire embedded in cement-based composite (MMCC). This is a contact-less type sensor that measures variations of magnetic properties resulting from stress variations. Sensors made of these materials can be designed to satisfy the specific demand for an economic way to monitor concrete infrastructure health. For this purpose, we embedded a thin magnetic microwire in the core of a cement-based cylinder, which was inserted into the concrete specimen under study as an extra aggregate. The experimental results show that the embedded MMCC sensor is capable of measuring internal compressive stress around the range of 1–30 MPa. Two stress sensing properties of the embedded sensor under uniaxial compression were studied: the peak amplitude and peak position of magnetic switching field. The sensitivity values for the amplitude and position within the measured range were 5 mV/MPa and 2.5 μs/MPa, respectively. PMID:25347582
[Schistosomiasis monitoring and its cost in population in Danyang City, 2010-2014].
Zhu, Tao; Jiang, Tao; Shi, Yu-kun; Wang, Juan
2015-12-01
To explore the monitoring method of the infection source of schistosomiasis in the population of the schistosomiasis transmission-interrupted area with Oncomelania hupensis snails. The changes of schistosomiasis among the population were investigated by using the active and passive monitoring methods in Danyang City from 2010 to 2014, and the cost-effectiveness of the two monitoring methods was evaluated. Totally 49,277 persons were detected for schistosomiasis by dipstick dye immunoassay (DDIA) from 2010 to 2014 and 608 cases were positive, and the positive rate was 1.23%. There were no positive persons by etiology detections. The positive rates of active and passive monitoring methods were 1.61% and 1.13%, respectively and there was a significant difference between them (χ² = 15.982, P < 0.05). The average cost per positive case of the active monitoring was higher than that of the passive monitoring without considering the costs of the mobilization and labor. In the schistosomiasis transmission-interrupted area with snails, the active and passive monitoring methods need to be combined in the future.
Wang, J S; Li, J R
2018-04-07
Objective: The consistency and characteristics of 24-hour multichannel intraluminal impedance(MII)-pH monitoring and Dx-pH monitoring in the diagnosis of laryngopharyngeal reflux were investigated. Methods: Fifty-two patients with laryngopharyngeal reflux related symptoms or disease between March and October 2017 were included in this study.All patients were evaluated with 24-hour MII-pH monitoring and Dx-pH monitoring at the same time, recording each patient's number of positive laryngopharyngeal reflux events, time of acid clearance and Ryan index.The data was analysed with Mann-Whitney U test and consistency check. Results: Among all 52 patients, 16 patients(30.7%) had a positive MII-pH monitoring result and 14 patients(26.9%) had a positive Dx-pH monitoring results.The consistency of both technique for measurement of laryngopharyngeal reflux was general(κ=0.626). With MII-pH monitoring for reference, the sensitivity and specificity of 24-hour pH monitoring were 68.8% and 91.7%.A total of 62 positive reflux events(pH<4) were measured with MII-pH monitoring, and 50 positive reflux events(upright pH<5.5 or supine pH<5.0)were detected by Dx-pH monitoring.There were 44 positive reflux events detected by both techniques, the mean time of acid clearance was 22.8[13.5; 42.6] s. Correspondingly, 18 reflux events were measured by MII-pH monitoring without positive results of Dx-pH monitoring, the mean time of acid clearance was 5.2[3.5; 6.5] s. There was significant difference in the time of acid clearance between two groups( U =858.5, P <0.05). Conclusions: Dx-pH monitoring can accurately measure the change of pH value in airway, but exists the possibility of misdiagnosis especially when the time of acid clearance in laryngopharynx is short. MII-pH and Dx-pH monitoring can be complementary technique in the diagnosis of laryngopharyngeal reflux.
The effect of observing session duration on OPUS-RS results
NASA Astrophysics Data System (ADS)
Dincer Dogru, A.; Ugur Sanli, D.; Hayal, Adem G.; Berber, Mustafa
2016-04-01
Online GPS positioning software has now a widespread interest among practitioners and researchers. Researchers rescently use online software to monitor natural hazards such as landslides. The fact that this software usually employs continuously operating GPS stations of the International GNSS Service (IGS) as reference stations in the processing, the community of world-wide users is growing day by day. In the monitoring of landslides, rapid static mode of a GPS surveying is usually preferred because it is possible to have wider field coverage with only a few minutes of data and low cost ground markers. Results comparable to static positioning can be obtained with careful network design and processing strategies. Some online software such as OPUS-RS developed by the National Geodetic Survey (NGS) of the USA provides rapid static positioning engine that processes GPS data from sessions of only a few minutes. 15-minute is the recommended/standard observing session duration for OPUS-RS processing. In this study, using the CORS data operating in the US, we carried out some tests in which the observing session duration is changed from 8 through 118 minutes, and observed the accuracy change on the OPUS-RS solutions. Then we compared the results with the accuracy levels given for 15-min solutions by the NGS. We determined that there is the effect of changing observing session duration on the obtained results, and we report them in this study.
Gunningberg, Lena; Carli, Cheryl
2016-10-01
The aim of this study was to (i) describe registered nurses' and assistant nurses' repositioning skills with regard to their existing attitudes to and theoretical knowledge of pressure ulcer (PU) prevention, and (ii) evaluate if the continuous bedside pressure mapping (CBPM) system provides staff with a pedagogic tool to optimise repositioning. A quantitative study was performed using a descriptive, comparative design. Registered nurses (n = 19) and assistant nurses (n = 33) worked in pairs, and were instructed to place two volunteers (aged over 70 years) in the best pressure-reducing position (lateral and supine), first without viewing the CBPM monitor and then again after feedback. In total, 240 positionings were conducted. The results show that for the same person with the same available pressure-reducing equipment, the peak pressure varied considerably between nursing pairs. Reducing pressure in the lateral position appeared to be the most challenging. Peak pressures were significantly reduced, based on visual feedback from the CBPM monitor. The number of preventive interventions also increased, as well as patients' comfort. For the nurses as a group, the knowledge score was 59·7% and the attitude score was 88·8%. Real-time visual feedback of pressure points appears to provide another dimension to complement decision making with respect to PU prevention. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Detecting Seismic Events Using a Supervised Hidden Markov Model
NASA Astrophysics Data System (ADS)
Burks, L.; Forrest, R.; Ray, J.; Young, C.
2017-12-01
We explore the use of supervised hidden Markov models (HMMs) to detect seismic events in streaming seismogram data. Current methods for seismic event detection include simple triggering algorithms, such as STA/LTA and the Z-statistic, which can lead to large numbers of false positives that must be investigated by an analyst. The hypothesis of this study is that more advanced detection methods, such as HMMs, may decreases false positives while maintaining accuracy similar to current methods. We train a binary HMM classifier using 2 weeks of 3-component waveform data from the International Monitoring System (IMS) that was carefully reviewed by an expert analyst to pick all seismic events. Using an ensemble of simple and discrete features, such as the triggering of STA/LTA, the HMM predicts the time at which transition occurs from noise to signal. Compared to the STA/LTA detection algorithm, the HMM detects more true events, but the false positive rate remains unacceptably high. Future work to potentially decrease the false positive rate may include using continuous features, a Gaussian HMM, and multi-class HMMs to distinguish between types of seismic waves (e.g., P-waves and S-waves). Acknowledgement: Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.SAND No: SAND2017-8154 A
Using Telescopic Observations to Mentor High School Students in STEM
NASA Astrophysics Data System (ADS)
McLin, K. M.; Cominsky, L. R.
2011-09-01
Over the past two summers (2009 and 2010) the NASA EPO Group at Sonoma State University (SSU) has sponsored local high school students in a summer science internship program at the University. The students, chosen from Sonoma County high schools in a competitive selection process, work in various science, technology, engineering, and mathematics (STEM) fields throughout the School of Science and Technology at SSU. The two interns sponsored by the EPO Group each summer monitor active galaxies using GORT, the NASA/Fermi-sponsored optical robotic telescope operated by the Group. They are mentored in their projects by EPO Group personnel and by SSU undergraduates who have experience with the telescope. The students learn about the sky, telescopes and the active galaxies they observe. They also learn how to make telescopic observations and how to reduce the CCD images obtained. Interns also participate in weekly meetings with other interns working on different projects around campus. At the end of the summer all the interns present their research results at a symposium held on campus.The symposium is attended by the interns themselves, their parents, their high school science teachers, and university faculty and administrators.The program has had a positive impact on how our interns view science, and specifically on their view of astronomy, as reported by the interns themselves in the first two years of the program.
The characteristics of medical retraction notices.
Snodgrass, G L; Pfeifer, M P
1992-01-01
During the past twenty years, more than ninety retraction notices have been published in biomedical journals. These retractions constitute a unique body of literature that biomedical researchers, bibliographers, and librarians must monitor to reduce scientific use of retracted, invalid papers. An analysis of medical retraction notices shows that very few are prominent in style, format, or placement, in spite of authoritative publication standards formulated by the International Council of Medical Journal Editors. Although researchers are ultimately responsible for the validity of the information they cite in their own publications, biomedical librarians are in a unique position to educate their patrons regarding retracted papers. PMID:1422502
Monitoring internal organ motion with continuous wave radar in CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfanner, Florian; Maier, Joscha; Allmendinger, Thomas
Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods:more » The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... I am an owner or operator of a stationary CI internal combustion engine? 60.4209 Section 60.4209... Combustion Engines Other Requirements for Owners and Operators § 60.4209 What are the monitoring requirements if I am an owner or operator of a stationary CI internal combustion engine? If you are an owner or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... I am an owner or operator of a stationary CI internal combustion engine? 60.4209 Section 60.4209... Combustion Engines Other Requirements for Owners and Operators § 60.4209 What are the monitoring requirements if I am an owner or operator of a stationary CI internal combustion engine? If you are an owner or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... I am an owner or operator of a stationary CI internal combustion engine? 60.4209 Section 60.4209... Combustion Engines Other Requirements for Owners and Operators § 60.4209 What are the monitoring requirements if I am an owner or operator of a stationary CI internal combustion engine? If you are an owner or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... I am an owner or operator of a stationary CI internal combustion engine? 60.4209 Section 60.4209... Combustion Engines Other Requirements for Owners and Operators § 60.4209 What are the monitoring requirements if I am an owner or operator of a stationary CI internal combustion engine? If you are an owner or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... I am an owner or operator of a stationary CI internal combustion engine? 60.4209 Section 60.4209... Combustion Engines Other Requirements for Owners and Operators § 60.4209 What are the monitoring requirements if I am an owner or operator of a stationary CI internal combustion engine? If you are an owner or...
Millman, Alexander J; Chamany, Shadi; Guthartz, Seth; Thihalolipavan, Sayone; Porter, Michael; Schroeder, Andrew; Vora, Neil M; Varma, Jay K; Starr, David
2016-01-29
The Ebola virus disease (Ebola) outbreak in West Africa has claimed approximately 11,300 lives (1), and the magnitude and course of the epidemic prompted many nonaffected countries to prepare for Ebola cases imported from affected countries. In October 2014, CDC and the Department of Homeland Security (DHS) implemented enhanced entry risk assessment and management at five U.S. airports: John F. Kennedy (JFK) International Airport in New York City (NYC), O'Hare International Airport in Chicago, Newark Liberty International Airport in New Jersey, Hartsfield-Jackson International Airport in Atlanta, and Dulles International Airport in Virginia (2). Enhanced entry risk assessment began at JFK on October 11, 2014, and at the remaining airports on October 16 (3). On October 21, DHS exercised its authority to direct all travelers flying into the United States from an Ebola-affected country to arrive at one of the five participating airports. At the time, the Ebola-affected countries included Guinea, Liberia, Mali, and Sierra Leone. On October 27, CDC issued updated guidance for monitoring persons with potential Ebola virus exposure (4), including recommending daily monitoring of such persons to ascertain the presence of fever or symptoms for a period of 21 days (the maximum incubation period of Ebola virus) after the last potential exposure; this was termed "active monitoring." CDC also recommended "direct active monitoring" of persons with a higher risk for Ebola virus exposure, including health care workers who had provided direct patient care in Ebola-affected countries. Direct active monitoring required direct observation of the person being monitored by the local health authority at least once daily (5). This report describes the operational structure of the NYC Department of Health and Mental Hygiene's (DOHMH) active monitoring program during its first 6 months (October 2014-April 2015) of operation. Data collected on persons who required direct active monitoring are not included in this report.
New generation of space capabilities resulting from US/RF cooperative efforts
NASA Astrophysics Data System (ADS)
Humpherys, Thomas; Misnik, Victor; Sinelshchikov, Valery; Stair, A. T., Jr.; Khatulev, Valery; Carpenter, Jack; Watson, John; Chvanov, Dmitry; Privalsky, Victor
2006-09-01
Previous successful international cooperative efforts offer a wealth of experience in dealing with highly sensitive issues, but cooperative remote sensing for monitoring and understanding the global environmental is in the national interest of all countries. Cooperation between international partners is paramount, particularly with the Russian Federation, due to its technological maturity and strategic political and geographical position in the world. Based on experience gained over a decade of collaborative space research efforts, continued cooperation provides an achievable goal as well as understanding the fabric of our coexistence. Past cooperative space research efforts demonstrate the ability of the US and Russian Federation to develop a framework for cooperation, working together on a complex, state-of-the-art joint satellite program. These efforts consisted of teams of scientists and engineers who overcame numerous cultural, linguistic, engineering approaches and different political environments. Among these major achievements are: (1) field measurement activities with US satellites MSTI and MSX and the Russian RESURS-1 satellite, as well as the joint experimental use of the US FISTA aircraft; (2) successful joint Science, Conceptual and Preliminary Design Reviews; (3) joint publications of scientific research technical papers, (4) Russian investment in development, demonstration and operation of the Monitor-E spacecraft (Yacht satellite bus), (5) successful demonstration of the conversion of the SS-19 into a satellite launch system, and (6) negotiation of contractual and technical assistant agreements. This paper discusses a new generation of science and space capabilities available to the Remote Sensing community. Specific topics include: joint requirements definition process and work allocation for hardware and responsibility for software development; the function, description and status of Russian contributions in providing space component prototypes and test articles; summary of planned experimental measurements and simulations; results of the ROKOT launch system; performance of the Monitor-E spacecraft; prototype joint mission operations control center; and a Handbook for Success in satellite collaborative efforts based upon a decade of lessons learned.
Anderson, Janet S.; LeMaster, David M.; Hernández, Griselda
2006-01-01
Hydrogen exchange measurements on Zn(II)-, Ga(III)-, and Ge(IV)-substituted Pyrococcus furiosus rubredoxin demonstrate that the log ratio of the base-catalyzed rate constants (Δ log kex) varies inversely with the distance out to at least 12 Å from the metal. This pattern is consistent with the variation of the amide nitrogen pK values with the metal charge-dependent changes in the electrostatic potential. Fifteen monitored amides lie within this range, providing an opportunity to assess the strength of electrostatic interactions simultaneously at numerous positions within the structure. Poisson-Boltzmann calculations predict an optimal effective internal dielectric constant of 6. The largest deviations between the experimentally estimated and the predicted ΔpK values appear to result from the conformationally mobile charged side chains of Lys-7 and Glu-48 and from differential shielding of the peptide units arising from their orientation relative to the metal site. PMID:17012322
[Research barometer: how is research activity monitored and how is it compared?].
Djurhuus, Jens Chr
2003-01-20
Recent analyses place Danish health science with the highest scientific impact per investment and the greatest share of most-cited papers globally. Several fields have international top score impact implying that they achieve more frequent citing than the average (Matthew effect). This appears paradoxical in view of the drastic reductions in Danish research budgets through the last 20 years--and the concomitant switch from long-term government grants to short-term external/private funding implying that continuity is replaced by demands for prompt results. Danish health research has thus proved remarkably robust under the steady downward tendency, but it is doubtful how far it will withstand current policy without irreversible damage. The methodologies applied in assessment of the excellence of research become increasingly sophisticated. They are still not completely reliable. At present they are primarily retrospective. It is imperative that future instruments monitor the actual research position.
Prgomet, Mirela; Cardona-Morrell, Magnolia; Nicholson, Margaret; Lake, Rebecca; Long, Janet; Westbrook, Johanna; Braithwaite, Jeffrey; Hillman, Ken
2016-09-01
Early detection of patient deterioration and prevention of adverse events are key challenges to patient safety. This study investigated clinical staff perceptions of current monitoring practices and the planned introduction of continuous monitoring devices on general wards. Multi-method study comprising structured surveys, in-depth interviews and device trial with log book feedback. Two general wards in a large urban teaching hospital in Sydney, Australia. Respiratory and neurosurgery nursing staff and two doctors. Nurses were confident about their abilities to identify patients at risk of deterioration, using a combination of vital signs and visual assessment. There were concerns about the accuracy of current vital signs monitoring equipment and frequency of intermittent observation. Both the nurses and the doctors were enthusiastic about the prospect of continuous monitoring and perceived it would allow earlier identification of patient deterioration; provide reassurance to patients; and support interdisciplinary communication. There were also reservations about continuous monitoring, including potential decrease in bedside nurse-patient interactions; increase in inappropriate escalations of patient care; and discomfort to patients. While continuous monitoring devices were seen as a potentially positive tool to support the identification of patient deterioration, drawbacks, such as the potential for reduced patient contact, revealed key areas that will require close surveillance following the implementation of devices. Training and improved interdisciplinary communication were identified as key requisites for successful implementation. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
UPLC-MS/MS method for therapeutic drug monitoring of 10 antibiotics used in intensive care units.
El-Najjar, Nahed; Hösl, Julian; Holzmann, Thomas; Jantsch, Jonathan; Gessner, André
2018-03-01
A large variation in the levels of different ß-lactams and other antibiotics used in critically ill patients has been documented. The aim of this study is to establish and validate a fast, ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous analysis of ten antibiotics (Meropenem, Cefepime, Ceftazidime, Piperacillin, Benzylpenicillin, Ampicillin, Flucloxacillin, Linezolid, and Sulfamethoxazole/Trimethoprim) in human plasma according to European Medicines Agency (EMA) guidelines. Protein precipitation with ice-cold methanol containing 9 isotopically labeled internal standards was used for sample clean up. Antibiotics were detected, following a 4-minute gradient separation, in multiple reactions monitoring (MRM) using API 4000 instrument equipped with electrospray source operating in positive ion mode. The lower limit of quantification was 0.1 mg/L for Meropenem, Ceftazidime, Piperacillin, Ampicillin, Flucloxacillin, and Sulfamethoxazole; 0.05 mg/L for Cefepime, Benzylpenicillin, and Trimethoprim; and 0.02 mg/L for Linezolid. The method proved to be precise and accurate and applicable for therapeutic drug monitoring and other pharmacokinetic studies. Copyright © 2017 John Wiley & Sons, Ltd.
International AGN Watch: Continuous Monitoring of NGC 4151
NASA Technical Reports Server (NTRS)
Crenshaw, D. M.
1995-01-01
The nucleus of NGC 4151 was observed continuously with the International Ultraviolet Explorer (IUE) for 9.3 days, yielding a pair of LWP and SWP spectra every 70 minutes, and during four-hour periods for 4 days prior to and 5 days after the continuous monitoring period. The sampling frequency of the observations is an order of magnitude higher than that of any previous UV monitoring campaign on a Seyfert galaxy.
Botto, Lorenzo D.; Robert-Gnansia, Elisabeth; Siffel, Csaba; Harris, John; Borman, Barry; Mastroiacovo, Pierpaolo
2006-01-01
The International Clearing-house for Birth Defects Surveillance and Research, formerly known as International Clearinghouse of Birth Defects Monitoring Systems, consists of 40 registries worldwide that collaborate in monitoring 40 types of birth defects. Clearinghouse activities include the sharing and joint monitoring of birth defect data, epidemiologic and public health research, and capacity building, with the goal of reducing disease and promoting healthy birth outcomes through primary prevention. We discuss 3 of these activities: the collaborative assessment of the potential teratogenicity of first-trimester use of medications (the MADRE project), an example of the intersection of surveillance and research; the international databases of people with orofacial clefts, an example of the evolution from surveillance to outcome research; and the study of genetic polymorphisms, an example of collaboration in public health genetics. PMID:16571708
Which blood oxygen can sensitively indicate shock severity?
NASA Astrophysics Data System (ADS)
Pan, Boan; Li, Kai; Gao, Yuan; Ruan, Zhengshang; Li, Ting
2016-03-01
Clinical shock-monitoring mainly depends on measuring oxygen saturations from SVC blood samples invasively. The golden standard indicator is the central internal jugular vein oxygenation (SjvO2). Using near-infrared spectroscopy (NIRS) also can monitor shock in some papers published, but there is no discussion about which oxygen saturation (cerebral venous oxygen saturation, ScvO2; tissue oxygen saturation of internal jugular area; tissue oxygen saturation of extremities areas) can monitor shock patient more sensitively and accurately. The purpose of this paper is to examine which one is most effective. In order to discuss the problem, we continuously detected 56 critical patients who may be into shock state using NIRS oximeter at prefrontal, internal jugular vein area and forearm, and chose 24 patients who were into shock and then out of shock from the 56 critical patients. Combined with the patients' condition, the pulse oxygen saturation is most sensitively to monitoring shock than the others, and the internal jugular vein area oxygen saturation is most effective.
Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I
2016-09-01
The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats Monitor
NASA Astrophysics Data System (ADS)
Bajaj, Varun
2016-10-01
The UVIS detector has a population of pixels that exhibit anomalous QE variations between anneals, characterized by a sensitivity loss that is greater in the blue than in the red. This population is randomly distributed, with evidence of clustering behavior in the UV, and is seemingly unique for each anneal cycle. This program, a continuation of cycle 23 program 14389, will aim to constrain the maximum low-sensitivity population existing before an anneal in both the UV and Visible filters. To monitor the UV behavior, internal flats with the D2 lamp will be taken through F225W and F336W. To monitor the behavior in the Visible filters, internal flats with the tungsten lamp will be taken a week before the anneal, when the population of anomalous pixels is the greatest. Internal flats with the Tungsten lamp will be taken to monitor the population in the visible filters, with data taken the week before the anneal to sample the maximum population of anomalous pixels.
Nomura, Shuhei; Tsubokura, Masaharu; Ozaki, Akihiko; Murakami, Michio; Hodgson, Susan; Blangiardo, Marta; Nishikawa, Yoshitaka; Morita, Tomohiro; Oikawa, Tomoyoshi
2017-01-01
Following Japan’s 2011 Fukushima nuclear incident, we assessed voluntary-based monitoring behavior in Minamisoma City—located 10–40 km from the Fukushima nuclear plant—to inform future monitoring strategies. The monitoring in Minamisoma included occasional free of charge internal-radiation-exposure measurements. Out of around 70,000 individuals residing in the city before the incident, a total of 45,788 residents (female: 52.1%) aged ≥21 were evaluated. The monitoring prevalence in 2011–2012 was only 30.2%, and this decreased to 17.9% in 2013–2014. Regression analyses were performed to estimate factors associated with the monitoring prevalence and participation behavior. The results show that, in comparison with the age cohort of 21–30 years, the cohort of 71–80 and ≥81 years demonstrated significantly lower monitoring prevalence; female residents had higher monitoring prevalence than male residents; those who were living in evacuation zones at the time of the incident had higher monitoring prevalence than those who lived outside any of the evacuation zones; for those living outside Fukushima and neighboring Prefectures post-incident monitoring prevalence decreased significantly in 2013–2014. Our findings inform the discussion on the concepts of radiation risk perception and accessibility to monitoring and societal decision-making regarding the maintenance of the monitoring program with low monitoring prevalence. We also stress the possibility that the monitoring can work both to check that internal contamination levels are within acceptable limits, and as a risk communication tool, alleviating individuals’ concern and anxiety over radiation contamination. PMID:28397769
Progress in using real-time GPS for seismic monitoring of the Cascadia megathrust
NASA Astrophysics Data System (ADS)
Szeliga, W. M.; Melbourne, T. I.; Santillan, V. M.; Scrivner, C.; Webb, F.
2014-12-01
We report on progress in our development of a comprehensive real-time GPS-based seismic monitoring system for the Cascadia subduction zone. This system is based on 1 Hz point position estimates computed in the ITRF08 reference frame. Convergence from phase and range observables to point position estimates is accelerated using a Kalman filter based, on-line stream editor. Positions are estimated using a short-arc approach and algorithms from JPL's GIPSY-OASIS software with satellite clock and orbit products from the International GNSS Service (IGS). The resulting positions show typical RMS scatter of 2.5 cm in the horizontal and 5 cm in the vertical with latencies below 2 seconds. To facilitate the use of these point position streams for applications such as seismic monitoring, we broadcast real-time positions and covariances using custom-built streaming software. This software is capable of buffering 24-hour streams for hundreds of stations and providing them through a REST-ful web interface. To demonstrate the power of this approach, we have developed a Java-based front-end that provides a real-time visual display of time-series, vector displacement, and contoured peak ground displacement. We have also implemented continuous estimation of finite fault slip along the Cascadia megathrust using an NIF approach. The resulting continuous slip distributions are combined with pre-computed tsunami Green's functions to generate real-time tsunami run-up estimates for the entire Cascadia coastal margin. This Java-based front-end is available for download through the PANGA website. We currently analyze 80 PBO and PANGA stations along the Cascadia margin and are gearing up to process all 400+ real-time stations operating in the Pacific Northwest, many of which are currently telemetered in real-time to CWU. These will serve as milestones towards our over-arching goal of extending our processing to include all of the available real-time streams from the Pacific rim. In addition, we are developing methodologies to combine our real-time solutions with those from Scripps Institute of Oceanography's PPP-AR real-time solutions as well as real-time solutions from the USGS. These combined products should improve the robustness and reliability of real-time point-position streams in the near future.
NASA Astrophysics Data System (ADS)
Lerner-Lam, A.
2007-05-01
Outside of the research community and mission agencies, global geophysical monitoring rarely receives sustained attention except in the aftermath of a humanitarian disaster. The recovery and rebuilding period focuses attention and resources for a short time on regional needs for geophysical observation, often at the national or sub-national level. This can result in the rapid deployment of national monitoring networks, but may overlook the longer-term benefits of integration with global networks. Even in the case of multinational disasters, such as the Indian Ocean tsunami, it has proved difficult to promote the integration of national solutions with global monitoring, research and operations infrastructure. More importantly, continuing operations at the national or sub-national scale are difficult to sustain once the resources associated with recovery and rebuilding are depleted. Except for some notable examples, the vast infrastructure associated with global geophysical monitoring is not utilized constructively to promote the integration of national networks with international efforts. This represents a missed opportunity not only for monitoring, but for developing the international research and educational collaborations necessary for technological transfer and capacity building. The recent confluence of highly visible disasters, global multi-hazard risk assessments, evaluations of the relationships between natural disasters and socio-economic development, and shifts in development agency policies, provides an opportunity to link global geophysical monitoring initiatives to central issues in international development. Natural hazard risk reduction has not been the first priority of international development agendas for understandable, mainly humanitarian reasons. However, it is now recognized that the so-called risk premium associated with making development projects more risk conscious or risk resilient is relatively small relative to potential losses. Thus there is an attitudinal shift emerging whereby disaster risk management can be "mainstreamed" into the sustainable development programs in many countries. Consequently, it is incumbent to demonstrate that multi-scale geophysical monitoring, comprising integration of global networks with national and sub-national operations, is a foundational component of sustainable development infrastructure. This suggests even greater emphasis on developing dynamic and adaptive multi- hazard risk assessments, encompassing valid estimates of social and physical vulnerabilities; designing multi- scale network integration strategies that consider risk as well as hazard; providing operational and flexible templates for developing national networks in a global context; emphasizing the backbone characteristics of global geophysical monitoring to nations seeking to develop their own monitoring capacity; promoting sustained international research, education and training collaborations coinciding with the development of monitoring capacity; and continuing to promote the free and open exchange of data as a necessary component of sustained intellectual interest in monitoring. A combination of these strategies may counteract the decay of interest in regional geophysical monitoring after a disaster.
Permutation Entropy Applied to Movement Behaviors of Drosophila Melanogaster
NASA Astrophysics Data System (ADS)
Liu, Yuedan; Chon, Tae-Soo; Baek, Hunki; Do, Younghae; Choi, Jin Hee; Chung, Yun Doo
Movement of different strains in Drosophila melanogaster was continuously observed by using computer interfacing techniques and was analyzed by permutation entropy (PE) after exposure to toxic chemicals, toluene (0.1 mg/m3) and formaldehyde (0.01 mg/m3). The PE values based on one-dimensional time series position (vertical) data were variable according to internal constraint (i.e. strains) and accordingly increased in response to external constraint (i.e. chemicals) by reflecting diversity in movement patterns from both normal and intoxicated states. Cross-correlation function revealed temporal associations between the PE values and between the component movement patterns in different chemicals and strains through the period of intoxication. The entropy based on the order of position data could be a useful means for complexity measure in behavioral changes and for monitoring the impact of stressors in environment.
Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Holubova, Michaela; Kantor, Krystof; Kolek, Antonin; Grambal, Aleš; Slepecky, Milos
2018-01-01
Patients who have schizophrenia are more prone to suicidal behavior than the general population. This study aimed to find connections between suicidality and self-stigma, hope, and personality traits in patients with schizophrenia. Forty-eight stabilized outpatients with schizophrenia attended this cross-sectional study. Patients were diagnosed by the Mini International Neuropsychiatric Interview (MINI) using the ICD-10 research diagnostic criteria. The assessments included Positive and Negative Syndrome Scale, objective and subjective Clinical Global Impression, Liebowitz Social Anxiety Scale, Beck Depression Inventory-second edition, Internalized Stigma of Mental Illness, the Temperament and Character Inventory, and Adult Dispositional Hope Scale. The individual rate of suicidality (suicidal index from MINI) strongly positively correlated with self-stigma, level of depression, social anxiety, and harm-avoidance, and negatively correlated with hope, self-directedness, and stigma resistance. Individuals with additional symptoms of depression, social anxiety, trait-like anxiety, and self-stigma should be carefully monitored for suicidal ideation. On the opposite side, patients with sufficient hope, self-esteem, and goal-directed attitudes are less likely to have suicidal thoughts and may potentially be role models in group rehabilitation programs, motivating more distressed colleagues and showing them ways to cope.
Chesnut, Randall M; Bleck, Thomas P; Citerio, Giuseppe; Classen, Jan; Cooper, D James; Coplin, William M; Diringer, Michael N; Grände, Per-Olof; Hemphill, J Claude; Hutchinson, Peter J; Le Roux, Peter; Mayer, Stephan A; Menon, David K; Myburgh, John A; Okonkwo, David O; Robertson, Claudia S; Sahuquillo, Juan; Stocchetti, Nino; Sung, Gene; Temkin, Nancy; Vespa, Paul M; Videtta, Walter; Yonas, Howard
2015-11-15
Widely-varying published and presented analyses of the Benchmark Evidence From South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial of intracranial pressure (ICP) monitoring have suggested denying trial generalizability, questioning the need for ICP monitoring in severe traumatic brain injury (sTBI), re-assessing current clinical approaches to monitored ICP, and initiating a general ICP-monitoring moratorium. In response to this dissonance, 23 clinically-active, international opinion leaders in acute-care sTBI management met to draft a consensus statement to interpret this study. A Delphi method-based approach employed iterative pre-meeting polling to codify the group's general opinions, followed by an in-person meeting wherein individual statements were refined. Statements required an agreement threshold of more than 70% by blinded voting for approval. Seven precisely-worded statements resulted, with agreement levels of 83% to 100%. These statements, which should be read in toto to properly reflect the group's consensus positions, conclude that the BEST TRIP trial: 1) studied protocols, not ICP-monitoring per se; 2) applies only to those protocols and specific study groups and should not be generalized to other treatment approaches or patient groups; 3) strongly calls for further research on ICP interpretation and use; 4) should be applied cautiously to regions with much different treatment milieu; 5) did not investigate the utility of treating monitored ICP in the specific patient group with established intracranial hypertension; 6) should not change the practice of those currently monitoring ICP; and 7) provided a protocol, used in non-monitored study patients, that should be considered when treating without ICP monitoring. Consideration of these statements can clarify study interpretation.
Swanney, Maureen P; O'Dea, Christopher A; Ingram, Emily R; Rodwell, Leanne T; Borg, Brigitte M
2017-10-01
Spirometry training courses are provided by health services and training organizations to enable widespread use of spirometry testing for patient care or for monitoring health. The primary outcome of spirometry training courses should be to enable participants to perform spirometry to international best practice, including testing of subjects, quality assurance and interpretation of results. Where valid results are not achieved or quality assurance programmes identify errors in devices, participants need to be able to adequately manage these issues in accordance with best practice. It is important that potential participants are confident in the integrity of the course they attend and that the course meets their expectations in terms of training. This position statement lists the content that the Australian and New Zealand Society of Respiratory Science (ANZSRS) has identified as required in a spirometry training course to adequately meet the primary outcomes mentioned above. The content requirements outlined in this position statement are based on the current international spirometry standards set out by the American Thoracic Society and European Respiratory Society. Furthermore, recommendations around course delivery for theoretical and practical elements of spirometry testing and post-course assessment are outlined in this statement. © 2017 The Authors. Respirology published by John Wiley & Sons Australia, Ltd on behalf of Asian Pacific Society of Respirology.
NASA Technical Reports Server (NTRS)
Lin, Paul P.; Jules, Kenol
2002-01-01
An intelligent system for monitoring the microgravity environment quality on-board the International Space Station is presented. The monitoring system uses a new approach combining Kohonen's self-organizing feature map, learning vector quantization, and back propagation neural network to recognize and classify the known and unknown patterns. Finally, fuzzy logic is used to assess the level of confidence associated with each vibrating source activation detected by the system.
Henrichs, K
2011-03-01
Besides ongoing developments in the dosimetry of incorporated radionuclides, there are various efforts to improve the monitoring of workers for potential or real intakes of radionuclides. The disillusioning experience with numerous intercomparison projects identified substantial differences between national regulations, concepts, applied programmes and methods, and dose assessment procedures. Measured activities were not directly comparable because of significant differences between measuring frequencies and methods, but also results of case studies for dose assessments revealed differences of orders of magnitude. Besides the general common interest in reliable monitoring results, at least the cross-border activities of workers (e.g. nuclear power plant services) require consistent approaches and comparable results. The International Standardization Organization therefore initiated projects to standardise programmes for the monitoring of workers, the requirements for measuring laboratories and the processes for the quantitative evaluation of monitoring results in terms of internal assessed doses. The strength of the concepts applied by the international working group consists in a unified approach defining the requirements, databases and processes. This paper is intended to give a short introduction into the standardization project followed by a more detailed description of the dose assessment standard, which will be published in the very near future.
49 CFR 192.477 - Internal corrosion control: Monitoring.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Internal corrosion control: Monitoring. 192.477 Section 192.477 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELIN...
49 CFR 192.477 - Internal corrosion control: Monitoring.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Internal corrosion control: Monitoring. 192.477 Section 192.477 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELIN...
49 CFR 192.477 - Internal corrosion control: Monitoring.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Internal corrosion control: Monitoring. 192.477 Section 192.477 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELIN...
Doukakis, Phaedra; Pikitch, Ellen K; Rothschild, Anna; DeSalle, Rob; Amato, George; Kolokotronis, Sergios-Orestis
2012-01-01
The international wildlife trade is a key threat to biodiversity. Temporal genetic marketplace monitoring can determine if wildlife trade regulation efforts such as the Convention on International Trade in Endangered Species (CITES) are succeeding. Protected under CITES effective 1997, sturgeons and paddlefishes, the producers of black caviar, are flagship CITES species. We test whether CITES has limited the amount of fraudulent black caviar reaching the marketplace. Using mitochondrial DNA-based methods, we compare mislabeling in caviar and meat purchased in the New York City area pre and post CITES listing. Our recent sampling of this market reveals a decrease in mislabeled caviar (2006-2008; 10%; n = 90) compared to pre-CITES implementation (1995-1996; 19%; n = 95). Mislabeled caviar was found only in online purchase (n = 49 online/41 retail). Stricter controls on importing and exporting as per CITES policies may be having a positive conservation effect by limiting the amount of fraudulent caviar reaching the marketplace. Sturgeons and paddlefishes remain a conservation priority, however, due to continued overfishing and habitat degradation. Other marine and aquatic species stand to benefit from the international trade regulation that can result from CITES listing.
Santos, M V; Sansinena, M; Zaritzky, N; Chirife, J
2013-01-01
The subject of present work was to predict internal temperature gradients developed during freezing of bovine sperm diluted in extender, packaged in 0.5 ml French plastic straws and suspended in static liquid nitrogen vapor at -100 degree C. For this purpose, a mathematical heat transfer model previously developed to predict freezing times (phase change was considered) of semen/extender packaged in straw was extended to predict internal temperature gradients during the cooling/freezing process. Results showed maximum temperature differences between the centre and the periphery of semen/extender "liquid" column was 1.5 degree C for an external heat transfer coefficient, h = 15 W per (m(2) K), and only 0.5 degree C for h = 5 W per (m(2) K). It is concluded that if a thermocouple wire were inserted in a 0.5 ml plastic straw to monitor the freezing process in nitrogen vapor, its radial position would have little importance since expected internal gradients may be safely neglected. This finding facilitates the interpretation of freezing rates in 0.5 ml plastic straws immersed in nitrogen vapor over liquid nitrogen, a widely used method for cryopreservation of bovine spermatozoa.
Weidling, Patrick; Jaschinski, Wolfgang
2015-01-01
When presbyopic employees are wearing general-purpose progressive lenses, they have clear vision only with a lower gaze inclination to the computer monitor, given the head assumes a comfortable inclination. Therefore, in the present intervention field study the monitor position was lowered, also with the aim to reduce musculoskeletal symptoms. A comparison group comprised users of lenses that do not restrict the field of clear vision. The lower monitor positions led the participants to lower their head inclination, which was linearly associated with a significant reduction in musculoskeletal symptoms. However, for progressive lenses a lower head inclination means a lower zone of clear vision, so that clear vision of the complete monitor was not achieved, rather the monitor should have been placed even lower. The procedures of this study may be useful for optimising the individual monitor position depending on the comfortable head and gaze inclination and the vertical zone of clear vision of progressive lenses. For users of general-purpose progressive lenses, it is suggested that low monitor positions allow for clear vision at the monitor and for a physiologically favourable head inclination. Employees may improve their workplace using a flyer providing ergonomic-optometric information.
A demonstration of centimeter-level monitoring of polar motion with the Global Positioning System
NASA Technical Reports Server (NTRS)
Lindqwister, U. J.; Freedman, A. P.; Blewitt, G.
1992-01-01
Daily estimates of the Earth's pole position were obtained with the Global Positioning System (GPS) by using measurements obtained during the GPS IERS (International Earth Rotation Service) and Geodynamics (GIG'91) experiment from 22 Jan. to 13 Feb. 1991. Data from a globally distributed network consisting of 21 Rogue GPS receivers were chosen for the analysis. A comparison of the GPS polar motion series with nine 24-hour very long baseline interferometry (VLBI) estimates yielded agreement in the day-to-day pole position of about 1.5 cm for both X and Y polar motion. A similar comparison of GPS and satellite laser ranging (SLR) data showed agreement to about 1.0 cm. These preliminary results indicate that polar motion can be determined by GPS independent of, and at a level comparable to, that which is obtained from either VLBI or SLR. Furthermore, GPS can provide these data with a daily frequency that neither alternative technique can readily achieve. Thus, GPS promises to be a powerful tool for determining high-frequency platform parameter variation, essential for the ultraprecise spacecraft-tracking requirements of the coming years.
Externalizing Behaviors of Ukrainian Children: The Role of Parenting
Burlaka, Viktor
2016-01-01
The purpose of this study was to assess the association of positive and negative parenting with child externalizing problems. Quantitative data were collected during face-to-face interviews with 320 parents of children 9–16 years of age (50% males) in 11 communities in Eastern, Southern and Central Ukraine. The study estimated the relationship between parenting practices and child externalizing behaviors, such as aggression, delinquency and attention problems. Results revealed that positive parenting, child monitoring, and avoidance of corporal punishment were associated with fewer child externalizing symptoms. Results also indicated that child male gender and single parenting had significant and positive association with child externalizing behaviors. This study extends international psychosocial knowledge on children and families. These findings can be used to design programs and foster dialogues about the role of family and social environments in the development of externalizing disorder among researchers, representatives of governmental and non-governmental organizations and mass media that work with child abuse prevention in Ukraine. PMID:26907365
Externalizing behaviors of Ukrainian children: The role of parenting.
Burlaka, Viktor
2016-04-01
The purpose of this study was to assess the association of positive and negative parenting with child externalizing problems. Quantitative data were collected during face-to-face interviews with 320 parents of children 9-16 years of age (50% males) in 11 communities in Eastern, Southern, and Central Ukraine. The study estimated the relationship between parenting practices and child externalizing behaviors such as aggression, delinquency, and attention problems. Results revealed that positive parenting, child monitoring, and avoidance of corporal punishment were associated with fewer child externalizing symptoms. Results also indicated that child male gender and single parenting had significant and positive association with child externalizing behaviors. This study extends international psychosocial knowledge on children and families. These findings can be used to design programs and foster dialogs about the role of family and social environments in the development of externalizing disorder among researchers, representatives of governmental and nongovernmental organizations, and mass media that work with child abuse prevention in Ukraine. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Zhenglin; Wang, Yuan; Sun, Yangyang; Zhang, Qinghua; You, Zewei; Huang, Xiaodi
2017-01-01
The precision of the encapsulated fiber optic sensor embedded into a host suffers from the influences of encapsulating materials. Furthermore, an interface transfer effect of strain sensing exists. This study uses an embedded basalt fiber-encapsulated fiber Bragg grating (FBG) sensor as the research object to derive an expression in a multilayer interface strain transfer coefficient by considering the mechanical properties of the host material. The direct impact of the host material on the strain transfer at an embedded multipoint continuous FBG (i.e., multiple gratings written on a single optical fiber) monitoring strain sensor, which was self-developed and encapsulated with basalt fiber, is studied to present the strain transfer coefficients corresponding to the positions of various gratings. The strain transfer coefficients of the sensor are analyzed based on the experiments designed for this study. The error of the experimental results is ˜2 μɛ when the strain is at 60 μɛ and below. Moreover, the measured curves almost completely coincide with the theoretical curves. The changes in the internal strain field inside the embedded structure of the basalt fiber-encapsulated FBG strain sensor could be easily monitored. Hence, important references are provided to measure the internal stress strain of the sensor.
Use of radar detectors to track attendance of albatrosses at fishing vessels
Filippi, D.P.; Collet, J.; Waugh, S.M.; Patrick, S.C.
2017-01-01
Abstract Despite international waters covering over 60% of the world's oceans, understanding of how fisheries in these regions shape ecosystem processes is surprisingly poor. Seabirds forage at fishing vessels, which has potentially deleterious effects for their population, but the extent of overlap and behavior in relation to ships is poorly known. Using novel biologging devices, which detect radar emissions and record the position of boats and seabirds, we measured the true extent of the overlap between seabirds and fishing vessels and generated estimates of the intensity of fishing and distribution of vessels in international waters. During breeding, wandering albatrosses (Diomedea exulans) from the Crozet Islands patrolled an area of over 10 million km2 at distances up to 2500 km from the colony. Up to 79.5% of loggers attached to birds detected vessels. The extent of overlap between albatrosses and fisheries has widespread implications for bycatch risk in seabirds and reveals the areas of intense fishing throughout the ocean. We suggest that seabirds equipped with radar detectors are excellent monitors of the presence of vessels in the Southern Ocean and offer a new way to monitor the presence of illegal fisheries and to better understand the impact of fisheries on seabirds. PMID:28598528
Use of radar detectors to track attendance of albatrosses at fishing vessels.
Weimerskirch, H; Filippi, D P; Collet, J; Waugh, S M; Patrick, S C
2018-02-01
Despite international waters covering over 60% of the world's oceans, understanding of how fisheries in these regions shape ecosystem processes is surprisingly poor. Seabirds forage at fishing vessels, which has potentially deleterious effects for their population, but the extent of overlap and behavior in relation to ships is poorly known. Using novel biologging devices, which detect radar emissions and record the position of boats and seabirds, we measured the true extent of the overlap between seabirds and fishing vessels and generated estimates of the intensity of fishing and distribution of vessels in international waters. During breeding, wandering albatrosses (Diomedea exulans) from the Crozet Islands patrolled an area of over 10 million km 2 at distances up to 2500 km from the colony. Up to 79.5% of loggers attached to birds detected vessels. The extent of overlap between albatrosses and fisheries has widespread implications for bycatch risk in seabirds and reveals the areas of intense fishing throughout the ocean. We suggest that seabirds equipped with radar detectors are excellent monitors of the presence of vessels in the Southern Ocean and offer a new way to monitor the presence of illegal fisheries and to better understand the impact of fisheries on seabirds. © 2017 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.
Dubey, Sunil Kumar; Saha, R N; Jangala, Hemanth; Pasha, S
2013-12-01
A new ultra-performance liquid chromatography-electrospray ionization mass spectrometry (UPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its metabolite O-desmethylvenlafaxine (ODV) in rat plasma has been developed and validated using Venlafaxine d6 as the internal standard. The compounds and internal standard were extracted from plasma by solid phase extraction. The UPLC separation of the analytes was performed on ACQUITY UPLC ® BEH Shield RP18 (1.7 µm, 100 mm×2.1 mm) column, using isocratic elution with mobile phase constituted of water (containing 2 mM ammonium acetate): acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. All of the analytes were eluted within 1.5 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer, operating in multiple reaction monitoring (MRM) and positive ion mode. The precursor to product ion transitions monitored for VEN, ODV and Venlafaxine d6 were m / z 278.3→121.08, 264.2→107.1 and 284.4→121.0, respectively. The developed and validated method was used for the pharmacokinetic study of VEN in rats.
Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet
2016-06-01
We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the inclusion of nursing-related standard operating procedures in certification/accreditation standards. © 2016 International Council of Nurses.
Trajectories of inner and outer heliospheric spacecraft: Predicted through 1999
NASA Technical Reports Server (NTRS)
Parthasarathy, R.; King, Joseph H.
1991-01-01
Information is presented in tabular and graphical form on the trajectories of the international fleet of spacecraft that will be probing the far reaches of the heliosphere during the 1990s. In particular, the following spacecraft are addressed: Pioneer 10 and 11, Pioneer Venus Orbiter (PVO), Voyager 1 and 2, Galileo, Ulysses, Suisei, Sakigake, Giotto, International Cometary Explorer (ICE), and Interplanetary Monitoring Platform 8 (IMP 8). Yearly resolution listing of position information in inertial space are given for Pioneer and Voyager spacecraft from the times of their launches in the 1970s. One series of plots shows the radial distances, latitudes, and longitudes of the Pioneers and Voyagers. The solar ecliptic inertial coordinate system is used. In this system, the Z axis is normal to the ecliptic plane and the X axis is towards the first point of Aries (from Sun to Earth on the vernal equinox).
The Significance of Forest Monitoring Programmes: the Finnish Perspective
NASA Astrophysics Data System (ADS)
Merila, P.; Derome, J.; Lindgren, M.
2007-12-01
Finland has been participating in the ICP Forests programme (the International Co-operative Programme on the Assessment and Monitoring of Air Pollution Effects on Forests) based on international agreements on the long- range transportation of air pollutants (LRTAP) and other associated monitoring programmes (e.g. Forest Focus, ICP Integrated Monitoring, ICP Vegetation) since 1985. The knowledge gained during the years has greatly increased our understanding of the overall condition of our forests and the factors affecting forest condition, the processes underlying forest ecosystem functioning, and the potential threats to our forests posed by human activities, both at home and abroad. The success of the monitoring activities in Finland is largely based on the experience gained during the early 1980's with our own national acidification project and, during the late 1980's and early 1990"s, in a number of regional monitoring projects. Finland's membership of the European Union (entry in 1996) has enabled us to further develop the infrastructure and coverage of both our extensive and intensive level networks. This broadening of our ecological understanding and development of international collaboration are now providing us with an invaluable basis for addressing the new monitoring challenges (biodiversity, climate change). The results gained in our monitoring activities clearly demonstrate the value of long-term monitoring programmes. The main results have been regularly reported both at the European (e.g. http://www.icp- forests.org/Reports.htm) and national level (e.g. http://www.metla.fi/julkaisut/workingpapers/2007/mwp045- en.htm). However, the datasets have not been intensively explored and exploited, and few of the important methodological and ecological findings have been published in peer-reviewed scientific journals. This has, understandably, not been the first priority of the international monitoring programmes. A number of the intensive forest monitoring plots in Finland have recently been included in LTER platforms, thus potentially increasing scientific collaboration between researchers across different governmental institutes and education bodies.
Conceptual frameworks for monitoring of high-altitude Andean ecosystems
David E. Busch; Xavier Silva
2006-01-01
The Ecuadorian government and its partner organizations in the international conservation community share an interest in developing monitoring programs for Andean protected areas to help support management for recreation, education, and ecological sustainability. To accomplish this goal, the U.S. Agency for International Development and the Department of the Interior...
ERIC Educational Resources Information Center
Noponen, Helzi
1997-01-01
An internal learning system (ILS), created for a development organization operating savings/credit programs with poor women, is used for data collection, monitoring, and evaluation. The ILS is participatory, pictorial, decentralized, and flexible; it documents socioeconomic impact and supports action planning. (SK)
Historical Radiological Event Monitoring
During and after radiological events EPA's RadNet monitors the environment for radiation. EPA monitored environmental radiation levels during and after Chernobyl, Fukushima and other international and domestic radiological incidents.
Jennings, I; Luddington, R J; Baglin, T
1991-01-01
The Ciba Corning Biotrack 512 coagulation monitor requires a minimal degree of technical expertise to operate, and is already in use for near-patient testing. This study evaluated the monitor for possible use in decentralised control of oral anticoagulant treatment. The monitor compared well with Manchester Reagent, suggesting that it could be used in areas where this thromboplastin is used for centralised control. The inability of the monitor to allow for locally determined geometric mean normal prothrombin times in the calculation of the International Normalised Ratio (INR), and possibly the high International Sensitivity Index (ISI) of the thromboplastin used with the monitor, resulted in poor comparability with some other thromboplastins, particularly Thrombotest. These problems need to be addressed if the monitor is to be used for decentralised anticoagulant control. PMID:1752987
Swaine, Bonnie; Dassa, Clément; Koné, Anna; Dutil, Élisabeth; Demers, Louise; Trempe, Claire
2017-01-01
Purpose To determine the factorial validity, internal consistency, criterion-related and concurrent validity of the Perception of Quality of Rehabilitation Services - Montreal (PQRS-Montreal) questionnaire for persons receiving traumatic brain injury (TBI) rehabilitation services. Design Cross-sectional study. Setting Seventeen facilities providing acute care and intensive inpatient and outpatient TBI adult rehabilitation. Participants Five-hundred thirty adults (GCS = 3-15; mean age = 41.5 ± 16.9 years) who received rehabilitation were administered the questionnaire during an interview near time of discharge. Subjects responded to the 61 PQRS-Montreal items (five-point scale of agreement) and to the Client Satisfaction Question (CSQ8). Results Exploratory and confirmatory factor analyses identified three potential subscales (one- and two-factor solutions) explaining 26.1-41% of the variance (ecological approach, quality of team, service organization). The subscales' internal structures were interpretable and their internal consistency varied from 0.51 to 0.90 (Cronbach's α). Rehabilitation phase significantly and positively impacted factor scores and all factor scores were significantly and moderately correlated with CSQ8 scores. Conclusions The PQRS-Montreal possesses adequate psychometric properties supporting its use as a valid tool to measure patients' perception of the quality of TBI rehabilitation services. This tool could help guide the development and monitoring of TBI rehabilitation service delivery. Implications for Rehabilitation The importance of measuring and monitoring quality of care is increasingly important in rehabilitation. Using the experiences and perceptions of care of service users is a valid way of assessing the quality of rehabilitation services. The PQRS-Montreal has adequate psychometric properties supporting its use as a valid tool to measure patients' perception of the quality of TBI rehabilitation services. This tool could help guide the development and monitoring of TBI rehabilitation service delivery.
Rapid culture-independent microbial analysis aboard the International Space Station (ISS).
Maule, Jake; Wainwright, Norm; Steele, Andrew; Monaco, Lisa; Morris, Heather; Gunter, Daniel; Damon, Michael; Wells, Mark
2009-10-01
A new culture-independent system for microbial monitoring, called the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was operated aboard the International Space Station (ISS). LOCAD-PTS was launched to the ISS aboard Space Shuttle STS-116 on December 9, 2006, and has since been used by ISS crews to monitor endotoxin on cabin surfaces. Quantitative analysis was performed within 15 minutes, and sample return to Earth was not required. Endotoxin (a marker of Gram-negative bacteria) was distributed throughout the ISS, despite previous indications that mostbacteria on ISS surfaces were Gram-positive [corrected].Endotoxin was detected at 24 out of 42 surface areas tested and at every surface site where colony-forming units (cfu) were observed, even at levels of 4-120 bacterial cfu per 100 cm(2), which is below NASA in-flight requirements (<10,000 bacterial cfu per 100 cm(2)). Absent to low levels of endotoxin (<0.24 to 1.0 EU per 100 cm(2); defined in endotoxin units, or EU) were found on 31 surface areas, including on most panels in Node 1 and the US Lab. High to moderate levels (1.01 to 14.7 EU per 100 cm(2)) were found on 11 surface areas, including at exercise, hygiene, sleeping, and dining facilities. Endotoxin was absent from airlock surfaces, except the Extravehicular Hatch Handle (>3.78 EU per 100 cm(2)). Based upon data collected from the ISS so far, new culture-independent requirements (defined in EU) are suggested, which are verifiable in flight with LOCAD-PTS yet high enough to avoid false alarms. The suggested requirements are intended to supplement current ISS requirements (defined in cfu) and would serve a dual purpose of safeguarding crew health (internal spacecraft surfaces <20 EU per 100 cm(2)) and monitoring forward contamination during Constellation missions (surfaces periodically exposed to the external environment, including the airlock and space suits, <0.24 EU per 100 cm(2)).
Poulsen, Per Rugaard; Worm, Esben Schjødt; Hansen, Rune; Larsen, Lars Peter; Grau, Cai; Høyer, Morten
2015-01-01
Intrafraction motion may compromise the target dose in stereotactic body radiation therapy (SBRT) of tumors in the liver. Respiratory gating can improve the treatment delivery, but gating based on an external surrogate signal may be inaccurate. This is the first paper reporting on respiratory gating based on internal electromagnetic monitoring during liver SBRT. Two patients with solitary liver metastases were treated with respiratory-gated SBRT guided by three implanted electromagnetic transponders. The treatment was delivered in end-exhale with beam-on when the centroid of the three transponders deviated less than 3 mm [left-right (LR) and anterior-posterior (AP) directions] and 4mm [cranio-caudal (CC)] from the planned position. For each treatment fraction, log files were used to determine the transponder motion during beam-on in the actual gated treatments and in simulated treatments without gating. The motion was used to reconstruct the dose to the clinical target volume (CTV) with and without gating. The reduction in D95 (minimum dose to 95% of the CTV) relative to the plan was calculated for both treatment courses. With gating the maximum course mean (standard deviation) geometrical error in any direction was 1.2 mm (1.8 mm). Without gating the course mean error would mainly increase for Patient 1 [to -2.8 mm (1.6 mm) (LR), 7.1 mm (5.8 mm) (CC), -2.6 mm (2.8mm) (AP)] due to a large systematic cranial baseline drift at each fraction. The errors without gating increased only slightly for Patient 2. The reduction in CTV D95 was 0.5% (gating) and 12.1% (non-gating) for Patient 1 and 0.3% (gating) and 1.7% (non-gating) for Patient 2. The mean duty cycle was 55%. Respiratory gating based on internal electromagnetic motion monitoring was performed for two liver SBRT patients. The gating added robustness to the dose delivery and ensured a high CTV dose even in the presence of large intrafraction motion.
Rapid Culture-Independent Microbial Analysis Aboard the International Space Station (ISS)
NASA Astrophysics Data System (ADS)
Maule, Jake; Wainwright, Norm; Steele, Andrew; Monaco, Lisa; Morris, Heather; Gunter, Daniel; Damon, Michael; Wells, Mark
2009-10-01
A new culture-independent system for microbial monitoring, called the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was operated aboard the International Space Station (ISS). LOCAD-PTS was launched to the ISS aboard Space Shuttle STS-116 on December 9, 2006, and has since been used by ISS crews to monitor endotoxin on cabin surfaces. Quantitative analysis was performed within 15 minutes, and sample return to Earth was not required. Endotoxin (a marker of Gram-negative bacteria and fungi) was distributed throughout the ISS, despite previous indications that most bacteria on ISS surfaces were Gram-positive. Endotoxin was detected at 24 out of 42 surface areas tested and at every surface site where colony-forming units (cfu) were observed, even at levels of 4-120 bacterial cfu per 100 cm2, which is below NASA in-flight requirements (<10,000 bacterial cfu per 100 cm2). Absent to low levels of endotoxin (<0.24 to 1.0 EU per 100 cm2; defined in endotoxin units, or EU) were found on 31 surface areas, including on most panels in Node 1 and the US Lab. High to moderate levels (1.01 to 14.7 EU per 100 cm2) were found on 11 surface areas, including at exercise, hygiene, sleeping, and dining facilities. Endotoxin was absent from airlock surfaces, except the Extravehicular Hatch Handle (>3.78 EU per 100 cm2). Based upon data collected from the ISS so far, new culture-independent requirements (defined in EU) are suggested, which are verifiable in flight with LOCAD-PTS yet high enough to avoid false alarms. The suggested requirements are intended to supplement current ISS requirements (defined in cfu) and would serve a dual purpose of safeguarding crew health (internal spacecraft surfaces <20 EU per 100 cm2) and monitoring forward contamination during Constellation missions (surfaces periodically exposed to the external environment, including the airlock and space suits, <0.24 EU per 100 cm2).
The American Society of Neurophysiological Monitoring position statements project.
Morledge, David E; Stecker, Mark
2006-02-01
The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents.
Wang, Manjie; Saudino, Kimberly J.
2015-01-01
Despite evidence for the associations of positive affect to prosocial behaviors and internalizing problems, relatively little is known about the underlying etiology. The sample comprised over 300 twin pairs at age 3. Positive affect, prosocial behaviors, and internalizing problems were assessed using the Toddler Behavior Assessment Questionnaire (Goldsmith, 1996), the Revised Rutter Parent Scale for Preschool Children (Hogg et al., 1997), and the Child Behavior Checklist for ages 1.5–5 (Achenbach, 1991), respectively. Positive affect correlated positively with prosocial behaviors, and negatively with internalizing problems. Prosocial behaviors were negatively associated with internalizing problems. The relations of positive affect to prosocial behaviors and internalizing problems were due to environmental effects (shared and non-shared). In contrast, the link between prosocial behaviors and internalizing problems was entirely explained by genetic effects. The current study has moved beyond prior emphasis on negative affect and elucidated the less understood etiology underlying the associations between positive affect, prosocial behaviors, and internalizing problems. This study could guide the development of programs for promoting prosocial behaviors and alleviating internalizing problems in children. PMID:25914668
Wang, Manjie; Saudino, Kimberly J
2015-01-01
Despite evidence for the associations of positive affect to prosocial behaviors and internalizing problems, relatively little is known about the underlying etiology. The sample comprised over 300 twin pairs at age 3. Positive affect, prosocial behaviors, and internalizing problems were assessed using the Toddler Behavior Assessment Questionnaire (Goldsmith, 1996), the Revised Rutter Parent Scale for Preschool Children (Hogg et al., 1997), and the Child Behavior Checklist for ages 1.5-5 (Achenbach, 1991), respectively. Positive affect correlated positively with prosocial behaviors, and negatively with internalizing problems. Prosocial behaviors were negatively associated with internalizing problems. The relations of positive affect to prosocial behaviors and internalizing problems were due to environmental effects (shared and non-shared). In contrast, the link between prosocial behaviors and internalizing problems was entirely explained by genetic effects. The current study has moved beyond prior emphasis on negative affect and elucidated the less understood etiology underlying the associations between positive affect, prosocial behaviors, and internalizing problems. This study could guide the development of programs for promoting prosocial behaviors and alleviating internalizing problems in children.
Performance of a Nanometer Resolution BPM System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walston, S.; Chung, C.; Fitsos, P.
2007-04-24
International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Acceleratormore » Test Facility (ATF) for testing with its ultra-low emittance beam. The three BPMs are rigidly mounted inside an alignment frame on variable-length struts which allow movement in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a calibration algorithm which is immune to beam jitter. To date, we have been able to demonstrate a resolution of approximately 20 nm over a dynamic range of +/- 20 microns. We report on the progress of these ongoing tests.« less
Development of Cloud-Based UAV Monitoring and Management System
Itkin, Mason; Kim, Mihui; Park, Younghee
2016-01-01
Unmanned aerial vehicles (UAVs) are an emerging technology with the potential to revolutionize commercial industries and the public domain outside of the military. UAVs would be able to speed up rescue and recovery operations from natural disasters and can be used for autonomous delivery systems (e.g., Amazon Prime Air). An increase in the number of active UAV systems in dense urban areas is attributed to an influx of UAV hobbyists and commercial multi-UAV systems. As airspace for UAV flight becomes more limited, it is important to monitor and manage many UAV systems using modern collision avoidance techniques. In this paper, we propose a cloud-based web application that provides real-time flight monitoring and management for UAVs. For each connected UAV, detailed UAV sensor readings from the accelerometer, GPS sensor, ultrasonic sensor and visual position cameras are provided along with status reports from the smaller internal components of UAVs (i.e., motor and battery). The dynamic map overlay visualizes active flight paths and current UAV locations, allowing the user to monitor all aircrafts easily. Our system detects and prevents potential collisions by automatically adjusting UAV flight paths and then alerting users to the change. We develop our proposed system and demonstrate its feasibility and performances through simulation. PMID:27854267
Development of Cloud-Based UAV Monitoring and Management System.
Itkin, Mason; Kim, Mihui; Park, Younghee
2016-11-15
Unmanned aerial vehicles (UAVs) are an emerging technology with the potential to revolutionize commercial industries and the public domain outside of the military. UAVs would be able to speed up rescue and recovery operations from natural disasters and can be used for autonomous delivery systems (e.g., Amazon Prime Air). An increase in the number of active UAV systems in dense urban areas is attributed to an influx of UAV hobbyists and commercial multi-UAV systems. As airspace for UAV flight becomes more limited, it is important to monitor and manage many UAV systems using modern collision avoidance techniques. In this paper, we propose a cloud-based web application that provides real-time flight monitoring and management for UAVs. For each connected UAV, detailed UAV sensor readings from the accelerometer, GPS sensor, ultrasonic sensor and visual position cameras are provided along with status reports from the smaller internal components of UAVs (i.e., motor and battery). The dynamic map overlay visualizes active flight paths and current UAV locations, allowing the user to monitor all aircrafts easily. Our system detects and prevents potential collisions by automatically adjusting UAV flight paths and then alerting users to the change. We develop our proposed system and demonstrate its feasibility and performances through simulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.
2016-02-29
This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within themore » exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).« less
Breath acetone to monitor life style interventions in field conditions: an exploratory study.
Samudrala, Devasena; Lammers, Gerwen; Mandon, Julien; Blanchet, Lionel; Schreuder, Tim H A; Hopman, Maria T; Harren, Frans J M; Tappy, Luc; Cristescu, Simona M
2014-04-01
To assess whether breath acetone concentration can be used to monitor the effects of a prolonged physical activity on whole body lipolysis and hepatic ketogenesis in field conditions. Twenty-three non-diabetic, 11 type 1 diabetic, and 17 type 2 diabetic subjects provided breath and blood samples for this study. Samples were collected during the International Four Days Marches, in the Netherlands. For each participant, breath acetone concentration was measured using proton transfer reaction ion trap mass spectrometry, before and after a 30-50 km walk on four consecutive days. Blood non-esterified free fatty acid (NEFA), beta-hydroxybutyrate (BOHB), and glucose concentrations were measured after walking. Breath acetone concentration was significantly higher after than before walking, and was positively correlated with blood NEFA and BOHB concentrations. The effect of walking on breath acetone concentration was repeatedly observed on all four consecutive days. Breath acetone concentrations were higher in type 1 diabetic subjects and lower in type 2 diabetic subjects than in control subjects. Breath acetone can be used to monitor hepatic ketogenesis during walking under field conditions. It may, therefore, provide real-time information on fat burning, which may be of use for monitoring the lifestyle interventions. Copyright © 2014 The Obesity Society.
Development of structural health monitoring techniques using dynamics testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, G.H. III
Today`s society depends upon many structures (such as aircraft, bridges, wind turbines, offshore platforms, buildings, and nuclear weapons) which are nearing the end of their design lifetime. Since these structures cannot be economically replaced, techniques for structural health monitoring must be developed and implemented. Modal and structural dynamics measurements hold promise for the global non-destructive inspection of a variety of structures since surface measurements of a vibrating structure can provide information about the health of the internal members without costly (or impossible) dismantling of the structure. In order to develop structural health monitoring for application to operational structures, developments inmore » four areas have been undertaken within this project: operational evaluation, diagnostic measurements, information condensation, and damage identification. The developments in each of these four aspects of structural health monitoring have been exercised on a broad range of experimental data. This experimental data has been extracted from structures from several application areas which include aging aircraft, wind energy, aging bridges, offshore structures, structural supports, and mechanical parts. As a result of these advances, Sandia National Laboratories is in a position to perform further advanced development, operational implementation, and technical consulting for a broad class of the nation`s aging infrastructure problems.« less
THE DESIGN OF PERFORMANCE MONITORING SYSTEMS IN HEALTHCARE ORGANIZATIONS: A STAKEHOLDER PERSPECTIVE.
Rouhana, Rima E; Van Caillie, Didier
2016-01-01
Monitoring hospitals performance is evolving over time in search of more efficiency by integrating additional levels of care, reducing costs and keeping staff up-to-date. To fulfill these three potentially divergent aspects and to monitor performance, healthcare administrators are using dissimilar management control tools. To explain why, we suggest to go beyond traditional contingent factors to assess the role of the different stakeholders that are at the heart of any healthcare organization. We rely first on seminal studies to appraise the role of the main healthcare players and their influence on some organizational attributes. We then consider the managerial awareness and the perception of a suitable management system to promote a strategy-focused organization. Our methodology is based on a qualitative approach of twenty-two case studies, led in two heterogeneous environments (Belgium and Lebanon), comparing the managerial choice of a management system within three different healthcare organizational structures. Our findings allow us to illustrate, for each healthcare player, his positioning within the healthcare systems. Thus, we define how his role, perception and responsiveness manipulate the organization's internal climate and shape the design of the performance monitoring systems. In particular, we highlight the managerial role and influence on the choice of an adequate management system.
Monitoring distances travelled by horses using GPS tracking collars.
Hampson, B A; Morton, J M; Mills, P C; Trotter, M G; Lamb, D W; Pollitt, C C
2010-05-01
The aims of this work were to (1) develop a low-cost equine movement tracking collar based on readily available components, (2) conduct preliminary studies assessing the effects of both paddock size and internal fence design on the movements of domestic horses, with and without foals at foot, and (3) describe distances moved by mares and their foals. Additional monitoring of free-ranging feral horses was conducted to allow preliminary comparisons with the movement of confined domestic horses. A lightweight global positioning system (GPS) data logger modified from a personal/vehicle tracker and mounted on a collar was used to monitor the movement of domestic horses in a range of paddock sizes and internal fence designs for 6.5-day periods. In the paddocks used (0.8-16 ha), groups of domestic horses exhibited a logarithmic response in mean daily distance travelled as a function of increasing paddock size, tending asymptotically towards approximately 7.5 km/day. The distance moved by newborn foals was similar to their dams, with total distance travelled also dependent on paddock size. Without altering available paddock area, paddock design, with the exception of a spiral design, did not significantly affect mean daily distance travelled. Feral horses (17.9 km/day) travelled substantially greater mean daily distances than domestic horses (7.2 km/day in 16-ha paddock), even when allowing for larger paddock size. Horses kept in stables or small yards and paddocks are quite sedentary in comparison with their feral relatives. For a given paddock area, most designs did not significantly affect mean daily distance travelled.
Wojnicz, Aneta; Gil García, Ana Isabel; Román-Martínez, Manuel; Ochoa-Mazarro, Dolores; Abad-Santos, Francisco; Ruiz-Nuño, Ana
2015-06-01
Omeprazole (OME) is a proton pump inhibitor with a 58% bioavailability after a single oral dose. It is subject to marked interindividual variations and significant drug-drug interactions. The authors developed a simple and rapid method based on liquid chromatography in tandem with mass spectrometry with solid phase extraction and isotope-labeled internal standard to monitor plasma levels of OME in pharmacokinetics and drug-drug interaction studies. OME and its internal standard (OME-D3) were eluted with a Zorbax Extend C-18 rapid resolution column (4.6 × 50 mm, 3.5 μm) at 25°C, under isocratic conditions through a mobile phase consisting of 1 mM ammonium acetate, pH 8.5 (55%), and acetonitrile (45%). The flow rate was 0.8 mL/min, and the chromatogram run time was 1.2 minutes. OME was detected and quantified by liquid chromatography in tandem with mass spectrometry with positive electrospray ionization, which operates in multiple-reaction monitoring mode. The method was linear in the range of 1.5-2000 ng/mL for OME. The validation assays for accuracy and precision, matrix effect, extraction recovery, and stability of the samples for OME did not deviate more than 20% for the lower limit of quantification and no more than 15% for other quality controls. These findings are consistent with the requirements of regulatory agencies. The method enables rapid quantification of OME concentrations and can be used in pharmacokinetic and drug-drug interaction studies.
Numerical Simulation and Mechanical Design for TPS Electron Beam Position Monitors
NASA Astrophysics Data System (ADS)
Hsueh, H. P.; Kuan, C. K.; Ueng, T. S.; Hsiung, G. Y.; Chen, J. R.
2007-01-01
Comprehensive study on the mechanical design and numerical simulation for the high resolution electron beam position monitors are key steps to build the newly proposed 3rd generation synchrotron radiation research facility, Taiwan Photon Source (TPS). With more advanced electromagnetic simulation tool like MAFIA tailored specifically for particle accelerator, the design for the high resolution electron beam position monitors can be tested in such environment before they are experimentally tested. The design goal of our high resolution electron beam position monitors is to get the best resolution through sensitivity and signal optimization. The definitions and differences between resolution and sensitivity of electron beam position monitors will be explained. The design consideration is also explained. Prototype deign has been carried out and the related simulations were also carried out with MAFIA. The results are presented here. Sensitivity as high as 200 in x direction has been achieved in x direction at 500 MHz.
Liebl, David; Difato, Francesco; Horníková, Lenka; Mannová, Petra; Štokrová, Jitka; Forstová, Jitka
2006-01-01
Mouse polyomavirus (PyV) virions enter cells by internalization into smooth monopinocytic vesicles, which fuse under the cell membrane with larger endosomes. Caveolin-1 was detected on monopinocytic vesicles carrying PyV particles in mouse fibroblasts and epithelial cells (33). Here, we show that PyV can be efficiently internalized by Jurkat cells, which do not express caveolin-1 and lack caveolae, and that overexpression of a caveolin-1 dominant-negative mutant in mouse epithelial cells does not prevent their productive infection. Strong colocalization of VP1 with early endosome antigen 1 (EEA1) and of EEA1 with caveolin-1 in mouse fibroblasts and epithelial cells suggests that the monopinocytic vesicles carrying the virus (and vesicles containing caveolin-1) fuse with EEA1-positive early endosomes. In contrast to SV40, PyV infection is dependent on the acidic pH of endosomes. Bafilomycin A1 abolished PyV infection, and an increase in endosomal pH by NH4Cl markedly reduced its efficiency when drugs were applied during virion transport towards the cell nucleus. The block of acidification resulted in the retention of a fraction of virions in early endosomes. To monitor further trafficking of PyV, we used fluorescent resonance energy transfer (FRET) to determine mutual localization of PyV VP1 with transferrin and Rab11 GTPase at a 2- to 10-nm resolution. Positive FRET between PyV VP1 and transferrin cargo and between PyV VP1 and Rab11 suggests that during later times postinfection (1.5 to 3 h), the virus meets up with transferrin in the Rab11-positive recycling endosome. These results point to a convergence of the virus and the cargo internalized by different pathways in common transitional compartments. PMID:16611921
Technical basis for internal dosimetry at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.
1991-07-01
The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ({sup 58}Co, {sup 60}Co, {sup 54}Mn, and {sup 59}Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78more » refs., 35 figs., 115 tabs.« less
Technical basis for internal dosimetry at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.
1989-04-01
The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products (/sup 58/Co, /sup 60/Co, /sup 54/Mn, and /sup 59/Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64more » refs., 42 figs., 118 tabs.« less
Swinburn, B; Sacks, G; Vandevijvere, S; Kumanyika, S; Lobstein, T; Neal, B; Barquera, S; Friel, S; Hawkes, C; Kelly, B; L'abbé, M; Lee, A; Ma, J; Macmullan, J; Mohan, S; Monteiro, C; Rayner, M; Sanders, D; Snowdon, W; Walker, C
2013-10-01
Non-communicable diseases (NCDs) dominate disease burdens globally and poor nutrition increasingly contributes to this global burden. Comprehensive monitoring of food environments, and evaluation of the impact of public and private sector policies on food environments is needed to strengthen accountability systems to reduce NCDs. The International Network for Food and Obesity/NCDs Research, Monitoring and Action Support (INFORMAS) is a global network of public-interest organizations and researchers that aims to monitor, benchmark and support public and private sector actions to create healthy food environments and reduce obesity, NCDs and their related inequalities. The INFORMAS framework includes two 'process' modules, that monitor the policies and actions of the public and private sectors, seven 'impact' modules that monitor the key characteristics of food environments and three 'outcome' modules that monitor dietary quality, risk factors and NCD morbidity and mortality. Monitoring frameworks and indicators have been developed for 10 modules to provide consistency, but allowing for stepwise approaches ('minimal', 'expanded', 'optimal') to data collection and analysis. INFORMAS data will enable benchmarking of food environments between countries, and monitoring of progress over time within countries. Through monitoring and benchmarking, INFORMAS will strengthen the accountability systems needed to help reduce the burden of obesity, NCDs and their related inequalities. © 2013 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of the International Association for the Study of Obesity.
Aglago, Elom Kouassivi; Landais, Edwige; Nicolas, Geneviève; Margetts, Barrie; Leclercq, Catherine; Allemand, Pauline; Aderibigbe, Olaide; Agueh, Victoire Damienne; Amuna, Paul; Annor, George Amponsah; El Ati, Jalila; Coates, Jennifer; Colaiezzi, Brooke; Compaore, Ella; Delisle, Hélène; Faber, Mieke; Fungo, Robert; Gouado, Inocent; El Hamdouchi, Asmaa; Hounkpatin, Waliou Amoussa; Konan, Amoin Georgette; Labzizi, Saloua; Ledo, James; Mahachi, Carol; Maruapula, Segametsi Ditshebo; Mathe, Nonsikelelo; Mbabazi, Muniirah; Mirembe, Mandy Wilja; Mizéhoun-Adissoda, Carmelle; Nzi, Clement Diby; Pisa, Pedro Terrence; El Rhazi, Karima; Zotor, Francis; Slimani, Nadia
2017-06-19
Collection of reliable and comparable individual food consumption data is of primary importance to better understand, control and monitor malnutrition and its related comorbidities in low- and middle-income countries (LMICs), including in Africa. The lack of standardised dietary tools and their related research support infrastructure remains a major obstacle to implement concerted and region-specific research and action plans worldwide. Citing the magnitude and importance of this challenge, the International Agency for Research on Cancer (IARC/WHO) launched the "Global Nutrition Surveillance initiative" to pilot test the use of a standardized 24-h dietary recall research tool (GloboDiet), validated in Europe, in other regions. In this regard, the development of the GloboDiet-Africa can be optimised by better understanding of the local specific methodological needs, barriers and opportunities. The study aimed to evaluate the standardized 24-h dietary recall research tool (GloboDiet) as a possible common methodology for research and surveillance across Africa. A consultative panel of African and international experts in dietary assessment participated in six e-workshop sessions. They completed an in-depth e-questionnaire to evaluate the GloboDiet dietary methodology before and after participating in the e-workshop. The 29 experts expressed their satisfaction on the potential of the software to address local specific needs when evaluating the main structure of the software, the stepwise approach for data collection and standardisation concept. Nevertheless, additional information to better describe local foods and recipes, as well as particular culinary patterns (e.g. mortar pounding), were proposed. Furthermore, food quantification in shared-plates and -bowls eating situations and interviewing of populations with low literacy skills, especially in rural settings, were acknowledged as requiring further specific considerations and appropriate solutions. An overall positive evaluation of the GloboDiet methodology by both African and international experts, supports the flexibility and potential applicability of this tool in diverse African settings and sets a positive platform for improved dietary monitoring and surveillance. Following this evaluation, prerequisite for future implementation and/or adaptation of GloboDiet in Africa, rigorous and robust capacity building as well as knowledge transfer will be required to roadmap a stepwise approach to implement this methodology across pilot African countries/regions.
Prone position craniotomy in pregnancy without fetal heart rate monitoring.
Jacob, Jean; Alexander, Ashish; Philip, Shoba; Thomas, Anoop
2016-09-01
A pregnant patient in second trimester scheduled for posterior fossa craniotomy in prone position is a challenge for the anesthesiologist. Things to consider are physiological changes during pregnancy, non-obstetric surgery in pregnant patients, neuroanesthetic principles, effects of prone positioning, and need for fetal heart rate (FHR) monitoring. We have described the anesthetic management of this case and discussed intra-operative FHR monitoring including controversies about its role, indications, and various options available as per fetal gestational age. In our case we attempted intermittent intra-operative FHR monitoring to optimize maternal positioning and fetal oxygenation even though the fetus was pre-viable. However the attempt was abandoned due to practical difficulties with prone positioning. Patient made good neurological recovery following the procedure and delivered a healthy term baby 4 months later. Decisions regarding fetal monitoring should be individualized based on viability of the fetus and feasibility of emergency cesarean delivery. Good communication between a multidisciplinary team involving neurosurgeon, anesthesiologist, obstetrician, and neonatologist is important for a successful outcome for mother and fetus. We conclude that prone position neurosurgery can safely be carried out in a pregnant patient with pre-viable fetus without FHR monitoring. Copyright © 2016 Elsevier Inc. All rights reserved.
10 CFR 60.143 - Monitoring and testing waste packages.
Code of Federal Regulations, 2010 CFR
2010-01-01
... package monitoring program shall include laboratory experiments which focus on the internal condition of... the laboratory experiments. (d) The waste package monitoring program shall continue as long as...
10 CFR 60.143 - Monitoring and testing waste packages.
Code of Federal Regulations, 2011 CFR
2011-01-01
... package monitoring program shall include laboratory experiments which focus on the internal condition of... the laboratory experiments. (d) The waste package monitoring program shall continue as long as...
10 CFR 60.143 - Monitoring and testing waste packages.
Code of Federal Regulations, 2012 CFR
2012-01-01
... package monitoring program shall include laboratory experiments which focus on the internal condition of... the laboratory experiments. (d) The waste package monitoring program shall continue as long as...
10 CFR 60.143 - Monitoring and testing waste packages.
Code of Federal Regulations, 2013 CFR
2013-01-01
... package monitoring program shall include laboratory experiments which focus on the internal condition of... the laboratory experiments. (d) The waste package monitoring program shall continue as long as...
10 CFR 60.143 - Monitoring and testing waste packages.
Code of Federal Regulations, 2014 CFR
2014-01-01
... package monitoring program shall include laboratory experiments which focus on the internal condition of... the laboratory experiments. (d) The waste package monitoring program shall continue as long as...
The Program for Regional and International Shorebird Monitoring (PRISM)
Jonathan Bart; Brad Andres; Stephen Brown; Garry Donaldson; Brian Harrington; Vicky Johnston; Stephanie Jones; Guy Morrison; Susan Skagen
2005-01-01
This report describes the “Program for Regional and International Shorebird Monitoring” (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird...
Valek, Rebecca M; Greenwald, Beverly J; Lewis, Carolyn C
2015-04-01
The authors discuss the psychological factors associated with weight loss maintenance and the use of Pender's health promotion model as a guide for the construction of clinical interventions to address these factors. The psychological factors include internal drive for weight maintenance, ongoing self-monitoring, long-term flexibility, positive mood and emotions, appropriate goals, and management of external stimuli. Nurse practitioners can help combat obesity trends through caring for patients in a holistic manner. Periodic psychological needs-assessments for patients who desire to maintain weight loss may further promote long-term success in weight management. © The Author(s) 2015.
Internal cycle modeling and environmental assessment of multiple cycle consumer products.
Tsiliyannis, C A
2012-01-01
Dynamic annual flow models incorporating consumer discard and usage loss and featuring deterministic and stochastic end-of-cycle (EOC) return by the consumer are developed for reused or remanufactured products (multiple cycle products, MCPs), including fast and slow cycling, short and long-lived products. It is shown that internal flows (reuse and overall consumption) increase proportionally to the dimensionless internal cycle factor (ICF) which is related to environmental impact reduction factors. The combined reuse/recycle (or cycle) rate is shown capable for shortcut, albeit effective, monitoring of environmental performance in terms of waste production, virgin material extraction and manufacturing impacts of all MCPs, a task, which physical variables (lifetime, cycling frequency, mean or total number of return trips) and conventional rates, via which environmental policy has been officially implemented (e.g. recycling rate) cannot accomplish. The cycle rate is shown to be an increasing (hyperbolic) function of ICF. The impact of the stochastic EOC return characteristics on total reuse and consumption flows, as well as on eco-performance, is assessed: symmetric EOC return has a small, positive effect on performance compared to deterministic, while early shifted EOC return is more beneficial. In order to be efficient, environmental policy should set higher minimum reuse targets for higher trippage MCPs. The results may serve for monitoring, flow accounting and comparative eco-assessment of MCPs. They may be useful in identifying reachable and efficient reuse/recycle targets for consumer products and in planning return via appropriate labelling and digital coding for enhancing environmental performance, while satisfying consumer demand. Copyright © 2011 Elsevier Ltd. All rights reserved.
10 CFR 835.703 - Other monitoring records.
Code of Federal Regulations, 2010 CFR
2010-01-01
....1102(d); (b) Results of monitoring used to determine individual occupational dose from external and internal sources; (c) Results of monitoring for the release and control of material and equipment as...
HASEGAWA, Mitsuhiro; NOURI, Mohsen; FUJISAWA, Hironori; HAYASHI, Yutaka; INAMASU, Joji; HIROSE, Yuichi; YAMASHITA, Junkoh
2015-01-01
There are many reports on position-related complications in neurosurgical literature but so far, continuous quantification of the patient’s position during the surgery has not been reported. This study aims to explore the utility of a new surgical table system and its software in displaying the patient’s body positions during surgery on real-time basis. More than 200 neurosurgical cases were monitored for their positions intra-operatively. The position was digitally recorded and could be seen by all the members in the operating team. It also displayed the three-dimensional relationship between the head and the heart positions. No position-related complications were observed during the study. The system was able to serve as an excellent indicator for monitoring the patient’s position. The recordings were analyzed and even used to reproduce or improve the position in the subsequent operations. The novel technique of monitoring the position of the head and the heart of the patients and the operating table planes are considered to be useful during delicate neurosurgical procedures thereby, preventing inadvertent procedural errors. This can be used to quantify various surgical positions in the future and define safety measures accordingly. PMID:25797776
Hasegawa, Mitsuhiro; Nouri, Mohsen; Fujisawa, Hironori; Hayashi, Yutaka; Inamasu, Joji; Hirose, Yuichi; Yamashita, Junkoh
2015-01-01
There are many reports on position-related complications in neurosurgical literature but so far, continuous quantification of the patient's position during the surgery has not been reported. This study aims to explore the utility of a new surgical table system and its software in displaying the patient's body positions during surgery on real-time basis. More than 200 neurosurgical cases were monitored for their positions intra-operatively. The position was digitally recorded and could be seen by all the members in the operating team. It also displayed the three-dimensional relationship between the head and the heart positions. No position-related complications were observed during the study. The system was able to serve as an excellent indicator for monitoring the patient's position. The recordings were analyzed and even used to reproduce or improve the position in the subsequent operations. The novel technique of monitoring the position of the head and the heart of the patients and the operating table planes are considered to be useful during delicate neurosurgical procedures thereby, preventing inadvertent procedural errors. This can be used to quantify various surgical positions in the future and define safety measures accordingly.
A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study
Schoot, Tessa S; Weenk, Mariska; van de Belt, Tom H; Engelen, Lucien JLPG; van Goor, Harry
2016-01-01
Background Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP self-measurement. Objective The objective of our study was to evaluate the performance of the first release of the Checkme Health Monitor (Viatom Technology), a cuffless BP monitor, in a real-life setting. Furthermore, we wanted to investigate whether the posture of the volunteer and the position of the device relative to the heart level would influence its outcomes. Methods Study volunteers fell into 3 BP ranges: high (>160 mmHg), normal (130–160 mmHg), and low (<130 mmHg). All requirements for test environment, observer qualification, volunteer recruitment, and BP measurements were met according to the European Society of Hypertension International Protocol (ESH-IP) for the validation of BP measurement devices. After calibrating the Checkme device, we measured systolic BP with Checkme and a validated, oscillometric reference BP monitor (RM). Measurements were performed in randomized order both in supine and in sitting position, and with Checkme at and above heart level. Results We recruited 52 volunteers, of whom we excluded 15 (12 due to calibration failure with Checkme, 3 due to a variety of reasons). The remaining 37 volunteers were divided into low (n=14), medium (n=13), and high (n=10) BP ranges. There were 18 men and 19 women, with a mean age of 54.1 (SD 14.5) years, and mean recruitment systolic BP of 141.7 (SD 24.7) mmHg. BP results obtained by RM and Checkme correlated well. In the supine position, the difference between the RM and Checkme was >5 mmHg in 17 of 37 volunteers (46%), of whom 9 of 37 (24%) had a difference >10 mmHg and 5 of 37 (14%) had a difference >15 mmHg. Conclusions BP obtained with Checkme correlated well with RM BP, particularly in the position (supine) in which the device was calibrated. These preliminary results are promising for conducting further research on cuffless BP measurement in the clinical and outpatient settings. PMID:27150527
Global Positioning System (GPS) civil signal monitoring (CSM) trade study report
DOT National Transportation Integrated Search
2014-03-07
This GPS Civil Signal Monitoring (CSM) Trade Study has been performed at the direction of DOT/FAA Navigation Programs as the agency of reference for consolidating civil monitoring requirements on the Global Positioning System (GPS). The objective of ...
Improvement of Gaofen-3 Absolute Positioning Accuracy Based on Cross-Calibration
Deng, Mingjun; Li, Jiansong
2017-01-01
The Chinese Gaofen-3 (GF-3) mission was launched in August 2016, equipped with a full polarimetric synthetic aperture radar (SAR) sensor in the C-band, with a resolution of up to 1 m. The absolute positioning accuracy of GF-3 is of great importance, and in-orbit geometric calibration is a key technology for improving absolute positioning accuracy. Conventional geometric calibration is used to accurately calibrate the geometric calibration parameters of the image (internal delay and azimuth shifts) using high-precision ground control data, which are highly dependent on the control data of the calibration field, but it remains costly and labor-intensive to monitor changes in GF-3’s geometric calibration parameters. Based on the positioning consistency constraint of the conjugate points, this study presents a geometric cross-calibration method for the rapid and accurate calibration of GF-3. The proposed method can accurately calibrate geometric calibration parameters without using corner reflectors and high-precision digital elevation models, thus improving absolute positioning accuracy of the GF-3 image. GF-3 images from multiple regions were collected to verify the absolute positioning accuracy after cross-calibration. The results show that this method can achieve a calibration accuracy as high as that achieved by the conventional field calibration method. PMID:29240675
NASA Astrophysics Data System (ADS)
Ulukavak, Mustafa; Yalcinkaya, Mualla
2016-04-01
The Global Positioning System (GPS) is used as an important tool for ionosphere monitoring and obtaining the Total Electron Content (TEC). GPS satellites, positioned in the Earth's orbit, are used as sensors to investigate the space weather conditions. In this study, solar and geomagnetic activity variations were investigated between the dates 1 March-30 June 2015 for the mid-latitude region. GPS-TEC variations were calculated for each selected International GNSS Service (IGS) station in Europe. GNSS data was obtained from Crustal Dynamics Data and Information System (CDDIS) archive. Solar and geomagnetic activity indices (Kp, F10.7 ve Dst) were obtained from the Oceanic and Atmospheric Administration (NOAA), the Canadian Space Weather Forecast Centre (CSWFC) and Data Analysis Center for geomagnetism and Space Magnetism Graduate School of Science, Kyoto University (WDC) archives. GPS-TEC variations were determined for the quiet periods of the solar and geomagnetic activities. GPS-TEC changes were then compared with respect to the quiet periods of the solar and geomagnetic activities. Global Ionosphere Maps (GIM) IONEX files, obtained from the IGS analysis center, was used to check the robustness of the GPS-TEC variations. The investigations revealed that it is possible to use the GPS-TEC data for monitoring the ionospheric disturbances.
Foot Modeling and Smart Plantar Pressure Reconstruction from Three Sensors
Ghaida, Hussein Abou; Mottet, Serge; Goujon, Jean-Marc
2014-01-01
In order to monitor pressure under feet, this study presents a biomechanical model of the human foot. The main elements of the foot that induce the plantar pressure distribution are described. Then the link between the forces applied at the ankle and the distribution of the plantar pressure is established. Assumptions are made by defining the concepts of a 3D internal foot shape, which can be extracted from the plantar pressure measurements, and a uniform elastic medium, which describes the soft tissues behaviour. In a second part, we show that just 3 discrete pressure sensors per foot are enough to generate real time plantar pressure cartographies in the standing position or during walking. Finally, the generated cartographies are compared with pressure cartographies issued from the F-SCAN system. The results show 0.01 daN (2% of full scale) average error, in the standing position. PMID:25400713
Foot modeling and smart plantar pressure reconstruction from three sensors.
Ghaida, Hussein Abou; Mottet, Serge; Goujon, Jean-Marc
2014-01-01
In order to monitor pressure under feet, this study presents a biomechanical model of the human foot. The main elements of the foot that induce the plantar pressure distribution are described. Then the link between the forces applied at the ankle and the distribution of the plantar pressure is established. Assumptions are made by defining the concepts of a 3D internal foot shape, which can be extracted from the plantar pressure measurements, and a uniform elastic medium, which describes the soft tissues behaviour. In a second part, we show that just 3 discrete pressure sensors per foot are enough to generate real time plantar pressure cartographies in the standing position or during walking. Finally, the generated cartographies are compared with pressure cartographies issued from the F-SCAN system. The results show 0.01 daN (2% of full scale) average error, in the standing position.
Kayser, Georgia L; Moriarty, Patrick; Fonseca, Catarina; Bartram, Jamie
2013-10-11
Monitoring of water services informs policy and planning for national governments and the international community. Currently, the international monitoring system measures the type of drinking water source that households use. There have been calls for improved monitoring systems over several decades, some advocating use of multiple indicators. We review the literature on water service indicators and frameworks with a view to informing debate on their relevance to national and international monitoring. We describe the evidence concerning the relevance of each identified indicator to public health, economic development and human rights. We analyze the benefits and challenges of using these indicators separately and combined in an index as tools for planning, monitoring, and evaluating water services. We find substantial evidence on the importance of each commonly recommended indicator--service type, safety, quantity, accessibility, reliability or continuity of service, equity, and affordability. Several frameworks have been proposed that give structure to the relationships among individual indicators and some combine multiple indicator scores into a single index but few have been rigorously tested. More research is needed to understand if employing a composite metric of indicators is advantageous and how each indicator might be scored and scaled.
Kayser, Georgia L.; Moriarty, Patrick; Fonseca, Catarina; Bartram, Jamie
2013-01-01
Monitoring of water services informs policy and planning for national governments and the international community. Currently, the international monitoring system measures the type of drinking water source that households use. There have been calls for improved monitoring systems over several decades, some advocating use of multiple indicators. We review the literature on water service indicators and frameworks with a view to informing debate on their relevance to national and international monitoring. We describe the evidence concerning the relevance of each identified indicator to public health, economic development and human rights. We analyze the benefits and challenges of using these indicators separately and combined in an index as tools for planning, monitoring, and evaluating water services. We find substantial evidence on the importance of each commonly recommended indicator—service type, safety, quantity, accessibility, reliability or continuity of service, equity, and affordability. Several frameworks have been proposed that give structure to the relationships among individual indicators and some combine multiple indicator scores into a single index but few have been rigorously tested. More research is needed to understand if employing a composite metric of indicators is advantageous and how each indicator might be scored and scaled. PMID:24157507
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goke, Sarah Hayes; Elliott, Nathan Ryan
The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program.more » The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.« less
Advances in volcano monitoring and risk reduction in Latin America
NASA Astrophysics Data System (ADS)
McCausland, W. A.; White, R. A.; Lockhart, A. B.; Marso, J. N.; Assitance Program, V. D.; Volcano Observatories, L. A.
2014-12-01
We describe results of cooperative work that advanced volcanic monitoring and risk reduction. The USGS-USAID Volcano Disaster Assistance Program (VDAP) was initiated in 1986 after disastrous lahars during the 1985 eruption of Nevado del Ruiz dramatizedthe need to advance international capabilities in volcanic monitoring, eruption forecasting and hazard communication. For the past 28 years, VDAP has worked with our partners to improve observatories, strengthen monitoring networks, and train observatory personnel. We highlight a few of the many accomplishments by Latin American volcano observatories. Advances in monitoring, assessment and communication, and lessons learned from the lahars of the 1985 Nevado del Ruiz eruption and the 1994 Paez earthquake enabled the Servicio Geológico Colombiano to issue timely, life-saving warnings for 3 large syn-eruptive lahars at Nevado del Huila in 2007 and 2008. In Chile, the 2008 eruption of Chaitén prompted SERNAGEOMIN to complete a national volcanic vulnerability assessment that led to a major increase in volcano monitoring. Throughout Latin America improved seismic networks now telemeter data to observatories where the decades-long background rates and types of seismicity have been characterized at over 50 volcanoes. Standardization of the Earthworm data acquisition system has enabled data sharing across international boundaries, of paramount importance during both regional tectonic earthquakes and during volcanic crises when vulnerabilities cross international borders. Sharing of seismic forecasting methods led to the formation of the international organization of Latin American Volcano Seismologists (LAVAS). LAVAS courses and other VDAP training sessions have led to international sharing of methods to forecast eruptions through recognition of precursors and to reduce vulnerabilities from all volcano hazards (flows, falls, surges, gas) through hazard assessment, mapping and modeling. Satellite remote sensing data-sharing facilitatescross-border identification and warnings of ash plumes for aviation. Overall, long-term strategies of data collection and experience-sharing have helped Latin American observatories improve their monitoring and create informed communities cognizant of vulnerabilities inherent in living near volcanoes.
NASA Astrophysics Data System (ADS)
Beecken, J.; Mellqvist, J.; Salo, K.; Ekholm, J.; Jalkanen, J.-P.
2014-07-01
A dedicated system for airborne ship emission measurements of SO2, NOx and particles has been developed and used from several small aircraft. The system has been adapted for fast response measurements at 1 Hz, and the use of several of the instruments is unique. The uncertainty of the given data is about 20% for SO2 and 24% for NOx emission factors. The mean values with one standard deviation for multiple measurements of 158 ships measured from the air on the Baltic and North Sea during 2011 and 2012 show emission factors of 18.8 ± 6.5 g kg-1 fuel , 66.6 ± 23.4 g kg-1 fuel and 1.8 ± 1.3 1016 particles kg-1 fuel for SO2, NOx and particle number, respectively. The particle size distributions were measured for particle diameters between 15 and 560 nm. The mean sizes of the particles are between 45 and 54 nm dependent on the distance to the source, and the number size distribution is monomodal. Concerning the sulfur fuel content, around 85% of the monitored ships comply with the International Maritime Organization (IMO) limits. The reduction of the sulfur emission control area (SECA) limit from 1.5 to 1% in 2010 appears to have contributed to reduction of sulfur emissions that were measured in earlier studies from 2007 to 2009. The presented method can be implemented for regular ship compliance monitoring.
Migration monitoring in shorebirds and landbirds: commonalities and differences
Susan K. Skagen; Jonathan Bart
2005-01-01
Several aspects of a developing program to monitor shorebirds in the western hemisphere are pertinent to migration monitoring of landbirds. Goals of the Program for Regional and International Shorebird Monitoring (PRISM) include estimating population size and population trends of 74 species, sub-species and distinct populations of North American shorebirds, monitoring...
Real-Time PCR with an Internal Control for Detection of All Known Human Adenovirus Serotypes▿
Damen, Marjolein; Minnaar, René; Glasius, Patricia; van der Ham, Alwin; Koen, Gerrit; Wertheim, Pauline; Beld, Marcel
2008-01-01
The “gold standard” for the diagnosis of adenovirus (AV) infection is virus culture, which is rather time-consuming. Especially for immunocompromised patients, in whom severe infections with AV have been described, rapid diagnosis is important. Therefore, an internally controlled AV real-time PCR assay detecting all known human AV serotypes was developed. Primers were chosen from the hexon region, which is the most conserved region, and in order to cover all known serotypes, degenerate primers were used. The internal control (IC) DNA contained the same primer binding sites as the AV DNA control but had a shuffled probe region compared to the conserved 24-nucleotide consensus AV hexon probe region (the target). The IC DNA was added to the clinical sample in order to monitor extraction and PCR efficiency. The sensitivity and the linearity of the AV PCR were determined. For testing the specificity of this PCR assay for human AVs, a selection of 51 AV prototype strains and 66 patient samples positive for other DNA viruses were tested. Moreover, a comparison of the AV PCR method described herein with culture and antigen (Ag) detection was performed with a selection of 151 clinical samples. All 51 AV serotypes were detected in the selection of AV prototype strains. Concordant results from culture or Ag detection and PCR were found for 139 (92.1%) of 151 samples. In 12 cases (7.9%), PCR was positive while the culture was negative. In conclusion, a sensitive, internally controlled nonnested AV real-time PCR assay which is able to detect all known AV serotypes with higher sensitivity than a culture or Ag detection method was developed. PMID:18923006
Adhesion of CdTe quantum dots on model membranes and internalization into RBL-2H3 cells.
Zhang, Mengmeng; Wei, Xiaoran; Ding, Lei; Hu, Jingtian; Jiang, Wei
2017-06-01
Quantum dots (QDs) have attracted broad attention due to their special optical properties and promising prospect in medical and biological applications. However, the process of QDs on cell membrane is worth further investigations because such process may lead to harmful effects on organisms and also important for QD application. In this study, adhesion of amino- and carboxyl-coated CdTe QDs (A-QDs and C-QDs) on cell membrane and the subsequent internalization are studied using a series of endocytosis-free model membranes, including giant and small unilamellar vesicles, supported lipid bilayers and giant plasma membrane vesicles (GPMVs). The adhered QD amounts on model membranes are quantified by a quartz crystal microbalance. The CdTe QD adhesion on model membranes is governed by electrostatic forces. Positively charged A-QDs adhere on GPMV surface and passively penetrate the plasma membrane via endocytosis-free mechanism, but negatively charged C-QDs cannot. Rat basophilic leukemia (RBL-2H3) cells are exposed to CdTe QDs to monitor the QD internalization process. Both A- and C-QDs are internalized by RBL-2H3 cells mainly via endocytosis. CdTe QDs do not accumulate on the plasma membrane of living cells due to the fast endocytosis and the weakened electrostatic attraction in biological medium, resulting in low chance of passive penetration. The suspended cells after trypsin digestion take more QDs than the adherent cells. A-QDs cause lower cell viability than C-QDs, probably because the approach of positively charged QDs to cells is favored and the smaller aggregates of A-QDs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Relph, Nicola; Herrington, Lee
2016-12-01
Following an ACL injury, reconstruction (ACL-R) and rehabilitation, athletes may return to play with a proprioceptive deficit. However, literature is lacking to support this hypothesis in elite athletic groups who have returned to international levels of performance. It is possible the potentially heightened proprioceptive ability evidenced in athletes may negate a deficit following injury. The purpose of this study was to consider the effects of ACL injury, reconstruction and rehabilitation on knee joint position sense (JPS) on a group of elite athletes who had returned to international performance. Using a cross-sectional design ten elite athletes with ACL-R and ten controls were evaluated. JPS was tested into knee extension and flexion using absolute error scores. Average data with 95% confidence intervals between the reconstructed, contralateral and uninjured control knees were analyzed using t-tests and effect sizes. The reconstructed knee of the injured group demonstrated significantly greater angle of error scores when compared to the contralateral and uninjured control into knee flexion (p=0.0001, r=0.98) and knee extension (p=0.0001, r=0.91). There were no significant differences between the contralateral uninjured knee of the injured group and the uninjured control group. Elite athletes who have had an ACL injury, reconstruction, rehabilitation and returned to international play demonstrate lower JPS ability compared to control groups. It is unclear if this deficiency affects long-term performance or secondary injury and re-injury problems. In the future physical therapists should monitor athletes longitudinally when they return to play. Copyright © 2016 Elsevier B.V. All rights reserved.
Choi, Edmond P H; Wong, Carlos K H; Wan, Eric Y F; Tsu, James H L; Chin, W Y; Kung, Kenny; Yiu, M K
2016-09-01
To examine the responsiveness of Functional Assessment of Cancer Therapy-Prostate (FACT-P) and Short Form-12 Health Survey version 2 (SF-12 v2) in prostate cancer patients because there is a lack of evidence to support their responsiveness in this patient population. One hundred sixty-eight subjects with prostate cancer were surveyed at baseline and at 6 months using the SF-12 v2 and FACT-P version 4. Internal responsiveness was assessed using paired t test and generalized estimating equation. External responsiveness was evaluated using receiver operating characteristic curve analysis. The internal responsiveness of the FACT-P and SF-12 v2 to detect positive change was satisfactory. The FACT-P and SF-12 v2 could not detect negative change. The FACT-P and the SF-12 v2 performed the best in distinguishing between improved general health and worsened general health. The FACT-P performed better in distinguishing between unchanged general health and worsened general health. The SF-12 v2 performed better in distinguishing between unchanged general health and improved general health. Positive change detected by these measures should be interpreted with caution as they might be too responsive to detect "noise," which is not clinically significant. The ability of the FACT-P and the SF-12 v2 to detect negative change was disappointing. The internal and external responsiveness of the social well-being of the FACT-P cannot be supported, suggesting that it is not suitable to longitudinally monitor the social component of HRQOL in prostate cancer patients. The study suggested that generic and disease-specific measures should be used together to complement each other.
USDA-ARS?s Scientific Manuscript database
Internal temperatures of honey bee hives kept at different sites in North Dakota were monitored before and during winter to evaluate the effects of treatment, in the form of exposure to commercial pollination, and location on colony health. In October, hives exposed to commercial pollination durin...
Yip, Hon Ming; Li, John C. S.; Cui, Xin; Gao, Qiannan; Leung, Chi Chiu
2014-01-01
As microfluidics has been applied extensively in many cell and biochemical applications, monitoring the related processes is an important requirement. In this work, we design and fabricate a high-throughput microfluidic device which contains 32 microchambers to perform automated parallel microfluidic operations and monitoring on an automated stage of a microscope. Images are captured at multiple spots on the device during the operations for monitoring samples in microchambers in parallel; yet the device positions may vary at different time points throughout operations as the device moves back and forth on a motorized microscopic stage. Here, we report an image-based positioning strategy to realign the chamber position before every recording of microscopic image. We fabricate alignment marks at defined locations next to the chambers in the microfluidic device as reference positions. We also develop image processing algorithms to recognize the chamber positions in real-time, followed by realigning the chambers to their preset positions in the captured images. We perform experiments to validate and characterize the device functionality and the automated realignment operation. Together, this microfluidic realignment strategy can be a platform technology to achieve precise positioning of multiple chambers for general microfluidic applications requiring long-term parallel monitoring of cell and biochemical activities. PMID:25133248
Home monitoring and decision support for international liver transplant children.
Song, Bianying; Schulze, Mareike; Goldschmidt, Imeke; Haux, Reinhold; Baumann, Ulrich; Marschollek, Michael
2013-01-01
Complications may occur after a liver transplantation, therefore proper monitoring and care in the post-operation phase plays a very important role. Sometimes, monitoring and care for patients from abroad is difficult due to a variety of reasons, e.g., different care facilities. The objective of our research for this paper is to design, implement and evaluate a home monitoring and decision support infrastructure for international children who underwent liver transplant operation. A point-of-care device and the PedsQL questionnaire were used in patients' home environment for measuring the blood parameters and assessing quality of life. By using a tablet PC and a specially developed software, the measured results were able to be transmitted to the health care providers via internet. So far, the developed infrastructure has been evaluated with four international patients/families transferring 38 records of blood test. The evaluation showed that the home monitoring and decision support infrastructure is technically feasible and is able to give timely alarm in case of abnormal situation as well as may increase parent's feeling of safety for their children.
Monitoring and Reporting Tools of the International Data Centre and International Monitoring System
NASA Astrophysics Data System (ADS)
Lastowka, L.; Anichenko, A.; Galindo, M.; Villagran Herrera, M.; Mori, S.; Malakhova, M.; Daly, T.; Otsuka, R.; Stangel, H.
2007-05-01
The Comprehensive Test-Ban Treaty (CTBT) which prohibits all nuclear explosions was opened for signature in 1996. Since then, the Preparatory Commission for the CTBT Organization has been working towards the establishment of a global verification regime to monitor compliance with the ban on nuclear testing. The International Monitoring System (IMS) comprises facilities for seismic, hydroacoustic, infrasound and radionuclide monitoring, and the means of communication. This system is supported by the International Data Centre (IDC), which provides objective products and services necessary for effective global monitoring. Upon completion of the IMS, 321 stations will be contributing to both near real-time and reviewed data products. Currently there are 194 facilities in IDC operations. This number is expected to increase by about 40% over the next few years, necessitating methods and tools to effectively handle the expansion. The requirements of high data availability as well as operational transparency are fundamental principals of IMS network operations, therefore, a suite of tools for monitoring and reporting have been developed. These include applications for monitoring Global Communication Infrastructure (GCI) links, detecting outages in continuous and segmented data, monitoring the status of data processing and forwarding to member states, and for systematic electronic communication and problem ticketing. The operation of the IMS network requires the help of local specialists whose cooperation is in some cases ensured by contracts or other agreements. The PTS (Provisional Technical Secretariat) strives to make the monitoring of the IMS as standardized and efficient as possible, and has therefore created the Operations Centre in which the use of most the tools are centralized. Recently the tasks of operations across all technologies, including the GCI, have been centralized within a single section of the organization. To harmonize the operations, an ongoing State of Health monitoring project will provide an integrated view of network, station and GCI performance and will provide system metrics. Comprehensive procedures will be developed to utilize this tool. However, as the IMS network expands, easier access to more information will cause additional challenges, mainly with human resources, to analyze and manage these metrics.
Bailey, Timothy S; Klaff, Leslie J; Wallace, Jane F; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A
2016-07-01
As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects' self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (-0.64% to -2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. © 2016 Diabetes Technology Society.
Cold chain monitoring during cold transportation of human corneas for transplantation.
Net, M; Trias, E; Navarro, A; Ruiz, A; Diaz, P; Fontenla, J R; Manyalich, M
2003-08-01
As recommended by international standards the cornea should be maintained in a specific temperature range (2 degrees -8 degrees C) to guarantee its viability. However, there is no standard packaging method to maintain these conditions during transport. Our packaging system is similar to those used by the main eye banks in Spain and elsewhere in Europe. The objective is to monitor the cold chain in the current packaging method to validate the maintenance of temperature within the adequate range for a minimum 24-hour period. The effects of the following variables were studied: number and freezing temperature of the cold packs; air volume in the packaging system; position of the cornea in the packaging system; and the wall section of the container. Exterior temperature was maintained constant at 20 degrees to 24 degrees C. The cold chain was monitored using a device that measures temperature continuously and for which a histogram of temperature variation can be downloaded to a computer for further analysis. When the cold packs were frozen to -40 degrees C or the number of cold packs increased to four, the temperature decreased quickly to 0 degrees C and the transport period was not prolonged. The main objective was to improve isolation by reducing inner air volume, and maintaining the position of the cornea in the container. The currently used cold packaging systems (not frozen, 4 degrees C) do not maintain the temperature within the accepted range for the required distribution period. The improved system maintains the cornea at between 2 degrees C and 6 degrees C for a minimum of 24 hours.
Hadar, Eran; Biron-Shental, Tal; Gavish, Oz; Raban, Oded; Yogev, Yariv
2015-08-01
We aimed to evaluate the performance of a non-invasive EMG electrical uterine monitor (EUM) versus tocodynamometry (TOCO) by comparing both to internal uterine pressure catheter (IUPC). Prospective observational trial. Uterine activity was recorded continuously and simultaneously, in women during active term labor, with TOCO, EUM and IUPC. Uterine activity tracings were analyzed by three blinded physicians. Overall, 385 tracings from 43 women were analyzed. A similar rate of interpretable tracings between physicians was demonstrated for EUM (87%; 95% CI 80.9-92.7%) and IUPC (94.8%; 95% CI 83.4-96.3%), with a significantly lower rate for TOCO (67.5%; 95% CI 59.4-76.8%, p < 0.001). There is a significant difference in the contraction frequency for EUM versus IUPC (0.77 ± 2.3) compared to TOCO versus IUPC (-3.34 ± 4.97). There is a high variability between the timing of TOCO contractions as compared to IUPC (4.74 ± 10.03 seconds), while a gap of 8.46 ± 4.24 seconds was detected for EUM. The sensitivity, positive predictive value and false positive rate for individual contraction identification by TOCO and EUM are 54.0%, 84.4%, 15.6% and 94.2%, 87.6%, 12.4%, respectively. EUM is efficient as IUPC for uterine activity assessment and both techniques are superior in comparison to external tocodynamometry. Our results support the use of non-invasive EMG technology to monitor uterine activity.
Kuzay, Tuncer M.; Shu, Deming
1995-01-01
A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.
Experimental investigation of leak detection using mobile distributed monitoring system
NASA Astrophysics Data System (ADS)
Chen, Jiang; Zheng, Junli; Xiong, Feng; Ge, Qi; Yan, Qixiang; Cheng, Fei
2018-01-01
The leak detection of rockfill dams is currently hindered by spatial and temporal randomness and wide monitoring range. The spatial resolution of fiber Bragg grating (FBG) temperature sensing technology is related to the distance between measuring points. As a result, the number of measuring points should be increased to ensure that the precise location of the leak is detected. However, this leads to a higher monitoring cost. Consequently, it is difficult to promote and apply this technology to effectively monitor rockfill dam leakage. In this paper, a practical mobile distributed monitoring system with dual-tubes is used by combining the FBG sensing system and hydrothermal cycling system. This dual-tube structure is composed of an outer polyethylene of raised temperature resistance heating pipe, an inner polytetrafluoroethylene tube, and a FBG sensor string, among which, the FBG sensor string can be dragged freely in the internal tube to change the position of the measuring points and improve the spatial resolution. In order to test the effectiveness of the system, the large-scale model test of concentrated leakage in 13 working conditions is carried out by identifying the location, quantity, and leakage rate of leakage passage. Based on Newton’s law of cooling, the leakage state is identified using the seepage identification index ζ v that was confirmed according to the cooling curve. Results suggested that the monitoring system shows high sensitivity and can improve the spatial resolution with limited measuring points, and thus better locate the leakage area. In addition, the seepage identification index ζ v correlated well with the leakage rate qualitatively.
19 CFR 360.104 - Steel import monitoring.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Steel import monitoring. 360.104 Section 360.104 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE STEEL IMPORT MONITORING AND ANALYSIS SYSTEM § 360.104 Steel import monitoring. (a) Throughout the duration of the licensing requirement...
19 CFR 360.104 - Steel import monitoring.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Steel import monitoring. 360.104 Section 360.104 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE STEEL IMPORT MONITORING AND ANALYSIS SYSTEM § 360.104 Steel import monitoring. (a) Throughout the duration of the licensing requirement...
19 CFR 360.104 - Steel import monitoring.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Steel import monitoring. 360.104 Section 360.104 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE STEEL IMPORT MONITORING AND ANALYSIS SYSTEM § 360.104 Steel import monitoring. (a) Throughout the duration of the licensing requirement...
19 CFR 360.104 - Steel import monitoring.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Steel import monitoring. 360.104 Section 360.104 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE STEEL IMPORT MONITORING AND ANALYSIS SYSTEM § 360.104 Steel import monitoring. (a) Throughout the duration of the licensing requirement...
19 CFR 360.104 - Steel import monitoring.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Steel import monitoring. 360.104 Section 360.104 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE STEEL IMPORT MONITORING AND ANALYSIS SYSTEM § 360.104 Steel import monitoring. (a) Throughout the duration of the licensing requirement...
Nuclear Explosion Monitoring History and Research and Development
NASA Astrophysics Data System (ADS)
Hawkins, W. L.; Zucca, J. J.
2008-12-01
Within a year after the nuclear detonations over Hiroshima and Nagasaki the Baruch Plan was presented to the newly formed United Nations Atomic Energy Commission (June 14, 1946) to establish nuclear disarmament and international control over all nuclear activities. These controls would allow only the peaceful use of atomic energy. The plan was rejected through a Security Council veto primarily because of the resistance to unlimited inspections. Since that time there have been many multilateral, and bilateral agreements, and unilateral declarations to limit or eliminate nuclear detonations. Almost all of theses agreements (i.e. treaties) call for some type of monitoring. We will review a timeline showing the history of nuclear testing and the more important treaties. We will also describe testing operations, containment, phenomenology, and observations. The Comprehensive Nuclear Test Ban Treaty (CTBT) which has been signed by 179 countries (ratified by 144) established the International Monitoring System global verification regime which employs seismic, infrasound, hydroacoustic and radionuclide monitoring techniques. The CTBT also includes on-site inspection to clarify whether a nuclear explosion has been carried out in violation of the Treaty. The US Department of Energy (DOE) through its National Nuclear Security Agency's Ground-Based Nuclear Explosion Monitoring R&D Program supports research by US National Laboratories, and universities and industry internationally to detect, locate, and identify nuclear detonations. This research program builds on the broad base of monitoring expertise developed over several decades. Annually the DOE and the US Department of Defense jointly solicit monitoring research proposals. Areas of research include: seismic regional characterization and wave propagation, seismic event detection and location, seismic identification and source characterization, hydroacoustic monitoring, radionuclide monitoring, infrasound monitoring, and data processing and analysis. Reports from the selected research projects are published in the proceedings of the annual Monitoring Research Review conference.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Designated contract market and swap execution facility position limits and accountability rules. (a) Spot... rules and procedures for monitoring and enforcing spot-month position limits set at levels no greater... monitoring and enforcing spot-month position limits set at levels no greater than 25 percent of estimated...
Code of Federal Regulations, 2013 CFR
2013-04-01
... Designated contract market and swap execution facility position limits and accountability rules. (a) Spot... rules and procedures for monitoring and enforcing spot-month position limits set at levels no greater... monitoring and enforcing spot-month position limits set at levels no greater than 25 percent of estimated...
Comparison of the Wake-up Test and Combined TES-MEP and CSEP Monitoring in Spinal Surgery.
Chen, Bailing; Chen, Yuguang; Yang, Junlin; Xie, Denghui; Su, Haihua; Li, Fobao; Wan, Yong; Peng, Xinsheng; Zheng, Zhaomin
2015-11-01
A retrospective clinical analysis. The aim of this study was to compare the effectiveness of the wake-up test with that of combined monitoring of transcranial electrical stimulation motor evoked potentials (TES-MEP) and cortical somatosensory evoked potentials (CSEP) in spinal surgery. TES-MEP/CSEP combined monitoring is being increasingly recognized as the ideal approach to detect spinal neurophysiological compromise during spinal surgery; however, as a result the merit of the wake-up test is now in doubt. TES-MEP/CSEP combined monitoring was performed simultaneously in 426 patients who underwent spinal surgery at our department, and wake-up tests were conducted on 23 patients because of positive neurophysiological monitoring results with uncertain causes or persistent positive monitoring findings after all potential causes had been resolved. Preoperative and postoperative neurological examinations were performed as the gold standard to detect irreversible spinal function compromise. All data were collected to compare the efficiency of TES-MEP/CSEP combined monitoring with that of the wake-up test. Positive results of TES-MEP/CSEP combined monitoring were recorded in 64 cases. Among them, the positive monitoring findings agreed with the results of the neurological examination in 51 cases, and the monitoring results did not match that of neurological examination in 13 cases. No false-negative result was observed. The sensitivity of TES-MEP/CSEP monitoring was 100%, the specificity was 96.5%, and the Youden index was 0.965. Wake-up tests were conducted in 23 cases. In 8 patients the positive monitoring findings completely matched the postoperative neurological examination results. In contrast, in the other 15 cases with negative neurophysiological monitoring results, only 9 patients retained intact neurological function and 6 patients suffered compromised neurological function. The sensitivity of the wake-up test was 57.1%, the specificity was 100%, and the Youden index was 0.571. Combined TES-MEP and CSEP monitoring, with its high sensitivity and specificity, is an effective method for monitoring spinal function during surgery and should be the preferred choice. The wake-up test is a useful complementary method for monitoring because of its high specificity.
Ogasawara, Kuniaki; Inoue, Takashi; Kobayashi, Masakazu; Endo, Hidehoko; Yoshida, Kenji; Fukuda, Takeshi; Terasaki, Kazunori; Ogawa, Akira
2005-02-01
Cerebral hyperperfusion syndrome is a rare but serious complication of carotid endarterectomy (CEA). The aim of the present study was to determine whether intraoperative blood flow velocity (BFV) monitoring in the middle cerebral artery (MCA) by using transcranial Doppler ultrasonography (TCD) could be used as a reliable technique to detect cerebral hyperperfusion following CEA by comparing findings with those of brain single photon emission CT (SPECT). Intraoperative BFV monitoring was attempted in 67 patients undergoing CEA for treatment of ipsilateral internal carotid artery (ICA) stenosis (> or =70%). Cerebral blood flow (CBF) was also assessed using SPECT, which was performed before and immediately after CEA. Intraoperative BFV monitoring was achieved in 60 patients. Of the 60 patients, post-CEA hyperperfusion (CBF increase > or =100%, compared with preoperative values) was observed in six patients. The sensitivity, specificity, and positive predictive value of the BFV increases immediately after declamping of the ICA for detecting post-CEA hyperperfusion was 100%, 94% and 67%, respectively, with a cut-off point 2.0-fold that of preclamping BFV. The sensitivity and specificity of the BFV increases at the end of the procedure for detecting post-CEA hyperperfusion were 100% for both parameters, with cut-off points of 2.0- to 2.2-fold BFV of preclamping value. Hyperperfusion syndrome developed in two patients with post-CEA hyperperfusion, but intracerebral hemorrhage did not occur. In one of these two patients, BFV monitoring was not possible because of failure to obtain an adequate bone window. Intraoperative MCA BFV monitoring by using TCD is a less reliable method to detect cerebral hyperperfusion following CEA than postoperative MCA BFV monitoring, provided adequate monitoring can be achieved.
Christian, Kira A.; Ijaz, Kashef; Dowell, Scott F.; Chow, Catherine C.; Chitale, Rohit A.; Bresee, Joseph S.; Mintz, Eric; Pallansch, Mark A.; Wassilak, Steven; McCray, Eugene; Arthur, Ray R.
2013-01-01
Disease outbreaks of international public health importance continue to occur regularly; detecting and tracking significant new public health threats in countries that cannot or might not report such events to the global health community is a challenge. The Centers for Disease Control and Prevention’s (CDC) Global Disease Detection (GDD) Operations Center, established in early 2007, monitors infectious and non-infectious public health events to identify new or unexplained global public health threats and better position CDC to respond, if public health assistance is requested or required. At any one time, the GDD Operations Center actively monitors approximately 30–40 such public health threats; here we provide our perspective on five of the top global infectious disease threats that we were watching in 2012: (1) avian influenza A (H5N1), (2) cholera, (3) wild poliovirus, (4) enterovirus-71, and (5) extensively drug-resistant tuberculosis. PMID:23827387
Monitoring of patients treated with lithium for bipolar disorder: an international survey.
Nederlof, M; Heerdink, E R; Egberts, A C G; Wilting, I; Stoker, L J; Hoekstra, R; Kupka, R W
2018-04-14
Adequate monitoring of patients using lithium is needed for optimal dosing and for early identification of patients with (potential) ADEs. The objective was to internationally assess how health care professionals monitor patients treated with lithium for bipolar disorder. Using networks of various professional organizations, an anonymous online survey was conducted among health care professionals prescribing lithium. Target lithium serum levels and frequency of monitoring was assessed together with monitoring of physical and laboratory parameters. Reasons to and not to monitor and use of guidelines and institutional protocols, and local monitoring systems were investigated. The survey was completed by 117 health care professionals incorporating responses from twenty-four countries. All prescribers reported to monitor lithium serum levels on a regular basis, with varying target ranges. Almost all (> 97%) monitored thyroid and renal function before start and during maintenance treatment. Reported monitoring of other laboratory and physical parameters was variable. The majority of respondents (74%) used guidelines or institutional protocols for monitoring. In general, the prescriber was responsible for monitoring, had to request every monitoring parameter separately and only a minority of patients was automatically invited. Lithium serum levels, renal and thyroid function were monitored by (almost) all physicians. However, there was considerable variation in other monitoring parameters. Our results help to understand why prescribers of lithium monitor patients and what their main reasons are not to monitor patients using lithium.
Doukakis, Phaedra; Pikitch, Ellen K.; Rothschild, Anna; DeSalle, Rob; Amato, George; Kolokotronis, Sergios-Orestis
2012-01-01
Background The international wildlife trade is a key threat to biodiversity. Temporal genetic marketplace monitoring can determine if wildlife trade regulation efforts such as the Convention on International Trade in Endangered Species (CITES) are succeeding. Protected under CITES effective 1997, sturgeons and paddlefishes, the producers of black caviar, are flagship CITES species. Methodology/Principal Findings We test whether CITES has limited the amount of fraudulent black caviar reaching the marketplace. Using mitochondrial DNA-based methods, we compare mislabeling in caviar and meat purchased in the New York City area pre and post CITES listing. Our recent sampling of this market reveals a decrease in mislabeled caviar (2006–2008; 10%; n = 90) compared to pre-CITES implementation (1995–1996; 19%; n = 95). Mislabeled caviar was found only in online purchase (n = 49 online/41 retail). Conclusions/Significance Stricter controls on importing and exporting as per CITES policies may be having a positive conservation effect by limiting the amount of fraudulent caviar reaching the marketplace. Sturgeons and paddlefishes remain a conservation priority, however, due to continued overfishing and habitat degradation. Other marine and aquatic species stand to benefit from the international trade regulation that can result from CITES listing. PMID:22848410
Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Holubova, Michaela; Kantor, Krystof; Kolek, Antonin; Grambal, Aleš; Slepecky, Milos
2018-01-01
Background and aim Patients who have schizophrenia are more prone to suicidal behavior than the general population. This study aimed to find connections between suicidality and self-stigma, hope, and personality traits in patients with schizophrenia. Methods Forty-eight stabilized outpatients with schizophrenia attended this cross-sectional study. Patients were diagnosed by the Mini International Neuropsychiatric Interview (MINI) using the ICD-10 research diagnostic criteria. The assessments included Positive and Negative Syndrome Scale, objective and subjective Clinical Global Impression, Liebowitz Social Anxiety Scale, Beck Depression Inventory-second edition, Internalized Stigma of Mental Illness, the Temperament and Character Inventory, and Adult Dispositional Hope Scale. Results The individual rate of suicidality (suicidal index from MINI) strongly positively correlated with self-stigma, level of depression, social anxiety, and harm-avoidance, and negatively correlated with hope, self-directedness, and stigma resistance. Conclusion Individuals with additional symptoms of depression, social anxiety, trait-like anxiety, and self-stigma should be carefully monitored for suicidal ideation. On the opposite side, patients with sufficient hope, self-esteem, and goal-directed attitudes are less likely to have suicidal thoughts and may potentially be role models in group rehabilitation programs, motivating more distressed colleagues and showing them ways to cope. PMID:29910618
Preparation of regional shorebird monitoring plans
Jonathan Bart; Ann Manning; Susan Thomas; Catherine Wightman
2005-01-01
Shorebird monitoring programs in Canada and the United States are being developed under the auspices of PRISM, the Program for Regional and International Shorebird Monitoring. PRISM provides a single blueprint for implementing the monitoring proposals in the shorebird conservation plans prepared recently in Canada and the United States. It includes four segments:...
NASA Astrophysics Data System (ADS)
Jézéquel, Tangi; Silvestre, Virginie; Dinis, Katy; Giraudeau, Patrick; Akoka, Serge
2018-04-01
Isotope ratio monitoring by 13C NMR spectrometry (irm-13C NMR) provides the complete 13C intramolecular position-specific composition at natural abundance. It represents a powerful tool to track the (bio)chemical pathway which has led to the synthesis of targeted molecules, since it allows Position-specific Isotope Analysis (PSIA). Due to the very small composition range (which represents the range of variation of the isotopic composition of a given nuclei) of 13C natural abundance values (50‰), irm-13C NMR requires a 1‰ accuracy and thus highly quantitative analysis by 13C NMR. Until now, the conventional strategy to determine the position-specific abundance xi relies on the combination of irm-MS (isotopic ratio monitoring Mass Spectrometry) and 13C quantitative NMR. However this approach presents a serious drawback since it relies on two different techniques and requires to measure separately the signal of all the carbons of the analyzed compound, which is not always possible. To circumvent this constraint, we recently proposed a new methodology to perform 13C isotopic analysis using an internal reference method and relying on NMR only. The method combines a highly quantitative 1H NMR pulse sequence (named DWET) with a 13C isotopic NMR measurement. However, the recently published DWET sequence is unsuited for samples with short T1, which forms a serious limitation for irm-13C NMR experiments where a relaxing agent is added. In this context, we suggest two variants of the DWET called Multi-WET and Profiled-WET, developed and optimized to reach the same accuracy of 1‰ with a better immunity towards T1 variations. Their performance is evaluated on the determination of the 13C isotopic profile of vanillin. Both pulse sequences show a 1‰ accuracy with an increased robustness to pulse miscalibrations compared to the initial DWET method. This constitutes a major advance in the context of irm-13C NMR since it is now possible to perform isotopic analysis with high relaxing agent concentrations, leading to a strong reduction of the overall experiment time.
Aguas, Patricia C; Fitzhenry, Matthew J; Giannikopoulos, Georgina; Varelis, Peter
2006-08-01
An accurate and precise method for the quantification of acrylamide using stable isotope dilution liquid chromatography-tandem mass spectrometry was developed and used to measure acrylamide in coffee and cocoa samples. The sample preparation involved extraction of the analyte and its internal standard, 13C3-acrylamide, into water and subsequent defatting of the aqueous extract with dichloromethane. An aliquot of the resulting aqueous extract was then azeotropically dried under reduced pressure and subsequently purified using an aminopropyl-bonded silica cartridge. The purified extracts were then chromatographed on a 5-microm 2.1 x 150 mm Hypercarb column, the effluent of which was monitored for the analyte and its internal standard using positive-ion APCI-selected reaction monitoring. The intra-laboratory reproducibility of the method, expressed as a relative coefficient of variation (%, n=5), was determined at four levels of concentration (12.3, 42.3, 139.3 and 464.8 microg kg(-1)) and was found to vary between 0.6-2.5%. The accuracy of the method was assessed using a reference sample of coffee. The average result obtained using our method differed from the assigned value of the reference material by less than 1%. An analysis of a cocoa sample revealed that the method is capable of precisely estimating acrylamide in challenging matrices down to a level of at least 12.3 microg kg(-1).
International Global Crop Condition Assessments in the framework of GEOGLAM
NASA Astrophysics Data System (ADS)
Becker-Reshef, I.; Justice, C. O.; Vermote, E.; Whitcraft, A. K.; Claverie, M.
2013-12-01
The Group on Earth Observations (partnership of governments and international organizations) developed the Global Agricultural Monitoring (GEOGLAM) initiative in response to the growing calls for improved agricultural information. The goal of GEOGLAM is to strengthen the international community's capacity to produce and disseminate relevant, timely and accurate forecasts of agricultural production at national, regional and global scales through the use of Earth observations. This initiative is designed to build on existing agricultural monitoring initiatives at national, regional and global levels and to enhance and strengthen them through international networking, operationally focused research, and data/method sharing. GEOGLAM was adopted by the G20 as part of the action plan on food price volatility and agriculture and is being implemented through building on the extensive GEO Agricultural Community of Practice (CoP) that was initiated in 2007 and includes key national and international agencies, organizations, and universities involved in agricultural monitoring. One of the early GEOGLAM activities is to provide harmonized global crop outlooks that offer timely qualitative consensus information on crop status and prospects. This activity is being developed in response to a request from the G-20 Agricultural Market Information System (AMIS) and is implemented within the global monitoring systems component of GEOGLAM. The goal is to develop a transparent, international, multi-source, consensus assessment of crop growing conditions, status, and agro-climatic conditions, likely to impact global production. These assessments are focused on the four primary crop types (corn, wheat, soy and rice) within the main agricultural producing regions of the world. The GEOGLAM approach is to bring together international experts from global, regional and national monitoring systems that can share and discuss information from a variety of independent complementary sources in order to reach a convergence of evidence based assessment. Information types include earth observations (EO) data and products, agro-meteorological data, crop models and field reports. To date, representatives from close to 20 different agencies have participated in these outlook assessments, which are submitted to AMIS on a monthly basis as well as shared with the international community. This talk will discuss the process, operational R&D, and progress towards developing these harmonized global crop assessments.
International Radiation Monitoring and Information System (IRMIS)
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Sanjoy; Baciu, Florian; Stowisek, Jan; Saluja, Gurdeep; Kenny, Patrick; Albinet, Franck
2017-09-01
This article describes the International Radiation Monitoring Information System (IRMIS) which was developed by the International Atomic Energy Agency (IAEA) with the goal to provide Competent Authorities, the IAEA and other international organizations with a client server based web application to share and visualize large quantities of radiation monitoring data. The data maps the areas of potential impact that can assist countries to take appropriate protective actions in an emergency. Ever since the Chernobyl nuclear power plant accident in April of 19861 European Community (EC) has worked towards collecting routine environmental radiological monitoring data from national networked monitoring systems. European Radiological Data Exchange Platform (EURDEP) was created in 19952 to that end - to provide radiation monitoring data from most European countries reported in nearly real-time. During the response operations for the Fukushima Dai-ichi nuclear power plant accident (March 2011) the IAEA Incident and Emergency Centre (IEC) managed, harmonized and shared the large amount of data that was being generated from different organizations. This task underscored the need for a system which allows sharing large volumes of radiation monitoring data in an emergency. In 2014 EURDEP started the submission of the European radiological data to the International Radiation Monitoring Information System (IRMIS) as a European Regional HUB for IRMIS. IRMIS supports the implementation of the Convention on Early Notification of a Nuclear Accident by providing a web application for the reporting, sharing, visualizing and analysing of large quantities of environmental radiation monitoring data during nuclear or radiological emergencies. IRMIS is not an early warning system that automatically reports when there are significant deviations in radiation levels or when values are detected above certain levels. However, the configuration of the visualization features offered by IRMIS may help Member States to determine where elevated gamma dose rate measurements during a radiological or nuclear emergency indicate that actions to protect the public are necessary. The data can be used to assist emergency responders determine where and when to take necessary actions to protect the public. This new web online tool supports the IAEA's Unified System for Information Exchange in Incidents and Emergencies (USIE)3, an online tool where competent authorities can access information about all emergency situations, ranging from a lost radioactive source to a full-scale nuclear emergency.
Data analysis of photon beam position at PLS-II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, J.; Shin, S., E-mail: tlssh@postech.ac.kr; Huang, Jung-Yun
In the third generation light source, photon beam position stability is critical issue on user experiment. Generally photon beam position monitors have been developed for the detection of the real photon beam position and the position is controlled by feedback system in order to keep the reference photon beam position. In the PLS-II, photon beam position stability for front end of particular beam line, in which photon beam position monitor is installed, has been obtained less than rms 1μm for user service period. Nevertheless, detail analysis for photon beam position data in order to demonstrate the performance of photon beammore » position monitor is necessary, since it can be suffers from various unknown noises. (for instance, a back ground contamination due to upstream or downstream dipole radiation, undulator gap dependence, etc.) In this paper, we will describe the start to end study for photon beam position stability and the Singular Value Decomposition (SVD) analysis to demonstrate the reliability on photon beam position data.« less
Analysis and control of the photon beam position at PLS-II
Ko, J.; Kim, I.-Y.; Kim, C.; Kim, D.-T.; Huang, J.-Y.; Shin, S.
2016-01-01
At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r.m.s. was achieved for a user service period in the beamline, where the photon beam position monitor is installed. Nevertheless, a detailed analysis of the photon beam position data was necessary in order to ensure the performance of the photon beam position monitor, since it can suffer from various unknown types of noise, such as background contamination due to upstream or downstream dipole radiation, and undulator gap dependence. This paper reports the results of a start-to-end study of the photon beam position stability and a singular value decomposition analysis to confirm the reliability of the photon beam position data. PMID:26917132
NASA Astrophysics Data System (ADS)
Green, David N.
2015-04-01
The spatial coherence structure of 30 infrasound array detections, with source-to-receiver ranges of 25-6500 km, has been measured within the 0.25-1 Hz passband. The data were recorded at International Monitoring System (IMS) microbarograph arrays with apertures of between 1 and 4 km. Such array detections are of interest for Comprehensive Nuclear-Test-Ban Treaty monitoring. The majority of array detections (e.g. 80 per cent of recordings in the third-octave passband centred on 0.63 Hz) exhibit spatial coherence loss anisotropy that is consistent with previous lower frequency atmospheric acoustic studies; coherence loss is more rapid perpendicular to the acoustic propagation direction than parallel to it. The thirty array detections display significant interdetection variation in the magnitude of spatial coherence loss. The measurements can be explained by the simultaneous arrival of wave fronts at the recording array with angular beamwidths of between 0.4 and 7° and velocity bandwidths of between 2 and 40 m s-1. There is a statistically significant positive correlation between source-to-receiver range and the magnitude of coherence loss. Acoustic multipathing generated by interactions with fine-scale wind and temperature gradients along stratospheric propagation paths is qualitatively consistent with the observations. In addition, the study indicates that to isolate coherence loss generated by propagation effects, analysis of signals exhibiting high signal-to-noise ratios (SNR) is required (SNR2 > 11 in this study). The rapid temporal variations in infrasonic noise observed in recordings at IMS arrays indicates that correcting measured coherence values for the effect of noise, using pre-signal estimates of noise power, is ineffective.
Free-living monitoring of Parkinson's disease: Lessons from the field.
Del Din, Silvia; Godfrey, Alan; Mazzà, Claudia; Lord, Sue; Rochester, Lynn
2016-09-01
Wearable technology comprises miniaturized sensors (eg, accelerometers) worn on the body and/or paired with mobile devices (eg, smart phones) allowing continuous patient monitoring in unsupervised, habitual environments (termed free-living). Wearable technologies are revolutionizing approaches to health care as a result of their utility, accessibility, and affordability. They are positioned to transform Parkinson's disease (PD) management through the provision of individualized, comprehensive, and representative data. This is particularly relevant in PD where symptoms are often triggered by task and free-living environmental challenges that cannot be replicated with sufficient veracity elsewhere. This review concerns use of wearable technology in free-living environments for people with PD. It outlines the potential advantages of wearable technologies and evidence for these to accurately detect and measure clinically relevant features including motor symptoms, falls risk, freezing of gait, gait, functional mobility, and physical activity. Technological limitations and challenges are highlighted, and advances concerning broader aspects are discussed. Recommendations to overcome key challenges are made. To date there is no fully validated system to monitor clinical features or activities in free-living environments. Robust accuracy and validity metrics for some features have been reported, and wearable technology may be used in these cases with a degree of confidence. Utility and acceptability appears reasonable, although testing has largely been informal. Key recommendations include adopting a multidisciplinary approach for standardizing definitions, protocols, and outcomes. Robust validation of developed algorithms and sensor-based metrics is required along with testing of utility. These advances are required before widespread clinical adoption of wearable technology can be realized. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
Isert, Mecki; Miesbach, Wolfgang; Schüttfort, Gundolf; Weil, Yvonne; Tirneci, Vanessa; Kasper, Alexander; Weber, Adele; Lindhoff-Last, Edelgard; Herrmann, Eva; Linnemann, Birgit
2015-08-01
Because of the possible interference of antiphospholipid antibodies (APL) with the phospholipid component of thromboplastin reagents, concerns have been raised about the validity of international normalized ratio (INR) testing to monitor anticoagulant therapy with vitamin K antagonists in patients with antiphospholipid syndrome (APS). To investigate the reliability of the INR, we determined the INR using various prothrombin time (PT) assays and compared the results with those of a chromogenic factor X (CFX) assay. The study cohort consisted of 40 APS patients and 100 APL-negative patients who were on anticoagulant therapy for reasons other than APS. The agreement (i.e. the percentage of patients with a difference ≤0.5 INR units) between the PT-derived INR and CFX-derived INR equivalents was only moderate in both patient groups. The best agreement with CFX-derived INR equivalents was observed for the Thromborel S reagent in APS patients (69.1 %) and for Neoplastin Plus in APL-negative patients (72.0 %). Regarding the results for the point-of-care system CoaguChek XS, an agreement between the INR and the CFX-derived INR equivalent was less frequently observed in the APS patients (55.6 vs. 67.8 %; p = 0.050). When considering all 3058 pairs of INR tests within the international sensitivity index (ISI)-calibrated range of 1.5 to 4.5 s, we did not observe a higher variability of INR values in either the APS patient group or the subgroup of APS patients positive for lupus coagulants compared with the APL-negative controls. In conclusion, monitoring vitamin K antagonists (VKA) therapy with laboratory INR measurements seems to be suitable for the majority of APS patients.
Beyond Kargil: The technology of peace in India-Pakistan border relations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tahir-Kheli, S.; Biringer, K.L.
2000-01-12
The potential for cooperation between India and Pakistan is substantial. Topics as widely varying as national security, the environment and trade hold the potential for improved bilateral relations. This paper looks at a few areas in which monitoring technology could contribute to enhancing cooperative border agreements between the two nations. The goal of the paper is not to provide prescriptive solutions to regional problems, but to expand the number of options being considered for improving Indian-Pakistan relations. Many of the impediments to bilateral progress are a result of a history of conflict and mistrust. By utilizing technical monitoring and inspections,more » each side can begin to replace suspicion and doubt with knowledge and information useful in making informed political, economic and military decisions. At the same time, technical monitoring and inspections can build confidence through common interactions. India and Pakistan have pledged to resolve their disputes, including Kashmir, through dialogue. Implementation of that pledge is influenced by a number of factors, including changes in the political systems and the fortunes of the leadership. Events of the past year and a half have severely tested these two governments' ability to move forward along a constructive and positive path. Testing of new missile systems both preceded and followed testing of nuclear weapons in May 1998. Both countries disregarded subsequent international displeasure as they proceeded to openly declare their respective nuclear capability. Their brief engagement with each other in February 1999 and movement toward a rapprochement diluted international condemnation of their nuclear activity. Within a recent period of nine months however, progress in the dialogue has been stalled first by the Pakistani move in Kashmir in May 1999, then by the Indian election in the summer of 1999 and most recently by the military coup in Pakistan.« less
Speckle-correlation monitoring of the microhemodynamics of internal organs
NASA Astrophysics Data System (ADS)
Zimnyakov, D. A.; Khmara, M. B.; Vilensky, M. A.; Kozlov, V. V.; Sadovoĭ, A. V.; Gorfinkel, I. V.; Zdrajevsky, R. A.; Isaeva, A. A.
2009-12-01
The results of preliminary experimental studies of the possibility of monitoring blood microcirculation in surface layers of internal organs of laboratory animals in the course of laparotomy using full-field speckle correlometry are presented. The transmission of laser radiation to the probed part of the organ and the delivery of scattered speckle-modulated radiation to the detector (a CMOS camera) are performed using a fiberoptic endoscopic system. In the course of experiments, the microhemodynamics of the intestine, liver, spleen, kidneys, and pancreas in rat in a normal state and under induced ischemia and peritonitis, as well as under the action of drugs with clearly pronounced vasodilative effects (lidocaine, papaverine), is studied. The problems and prospects of speckle-correlation monitoring of the microhemodynamics of internal organs under laboratory and clinical conditions are discussed.
NASA Astrophysics Data System (ADS)
Chu, J. B.; Conrad-Saydah, A.; Cohen, S.; Tom, R.; Robins-Moloney, M.; Masters, D.; Mason, K.; Alfaro, F.
2003-12-01
Student interns from the California Academy of Sciences' Careers in Sciences program monitored the Pacific mole crab (Emerita analoga), or sand crabs, in collaboration with the Farallones Marine Sanctuary Association. These small crustaceans live in the swash zone of the sandy beach habitat. Sand crabs are important in the food web, and therefore their status can help indicate the health of the larger environment. The interns helped the Gulf of the Farallones National Marine Sanctuary by monitoring the abundance and distribution of sand crabs at Ocean Beach in San Francisco, California. Students set up transects perpendicular to the shoreline, collected 10 samples along the transect, measured the carapace length, determined the sex of each crab, and checked for the presence of eggs. Students monitored June through September, 2003. Trends examined included differences in the gender ratio, size frequency, and distribution along the beach. Students also compared their data to other student data taken from other sites in San Francisco and Marin counties during 2001-2003 from the online database at http://www.sandcrabs.org. Using comparisons, interns were able to better understand the processes and significance of studying marine species. Implementation of the project was invaluable in aiding the interns in their understanding of the natural sciences and the role of monitoring habitats in environmental health.
NASA Astrophysics Data System (ADS)
Ganguli, Anurag; Saha, Bhaskar; Raghavan, Ajay; Kiesel, Peter; Arakaki, Kyle; Schuh, Andreas; Schwartz, Julian; Hegyi, Alex; Sommer, Lars Wilko; Lochbaum, Alexander; Sahu, Saroj; Alamgir, Mohamed
2017-02-01
A key challenge hindering the mass adoption of Lithium-ion and other next-gen chemistries in advanced battery applications such as hybrid/electric vehicles (xEVs) has been management of their functional performance for more effective battery utilization and control over their life. Contemporary battery management systems (BMS) reliant on monitoring external parameters such as voltage and current to ensure safe battery operation with the required performance usually result in overdesign and inefficient use of capacity. More informative embedded sensors are desirable for internal cell state monitoring, which could provide accurate state-of-charge (SOC) and state-of-health (SOH) estimates and early failure indicators. Here we present a promising new embedded sensing option developed by our team for cell monitoring, fiber-optic (FO) sensors. High-performance large-format pouch cells with embedded FO sensors were fabricated. This second part of the paper focuses on the internal signals obtained from these FO sensors. The details of the method to isolate intercalation strain and temperature signals are discussed. Data collected under various xEV operational conditions are presented. An algorithm employing dynamic time warping and Kalman filtering was used to estimate state-of-charge with high accuracy from these internal FO signals. Their utility for high-accuracy, predictive state-of-health estimation is also explored.
Kumanyika, S
2013-10-01
This supplement presents the foundational elements for INFORMAS (International Network for Food and Obesity/non-communicable diseases Research, Monitoring and Action Support). As explained in the overview article by Swinburn and colleagues, INFORMAS has a compelling rationale and has set forth clear objectives, outcomes, principles and frameworks for monitoring and benchmarking key aspects of food environments and the policies and actions that influence the healthiness of food environments. This summary highlights the proposed monitoring approaches for the 10 interrelated INFORMAS modules: public and private sector policies and actions; key aspects of food environments (food composition, labelling, promotion, provision, retail, prices, and trade and investment) and population outcomes (diet quality). This ambitious effort should be feasible when approached in a step-wise manner, taking into account existing monitoring efforts, data sources, country contexts and capacity, and when adequately resourced. After protocol development and pilot testing of the modules, INFORMAS aims to be a sustainable, low-cost monitoring framework. Future directions relate to institutionalization, implementation and, ultimately, to leveraging INFORMAS data in ways that will bring key drivers of food environments into alignment with public health goals. © 2013 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of the International Association for the Study of Obesity.
Levels-of-processing effect on internal source monitoring in schizophrenia
RAGLAND, J. DANIEL; McCARTHY, ERIN; BILKER, WARREN B.; RENSINGER, COLLEEN M. B; VALDEZ, JEFFREY; KOHLER, CHRISTIAN; GUR, RAQUEL E.; GUR, RUBEN C.
2015-01-01
Background Recognition can be normalized in schizophrenia by providing patients with semantic organizational strategies through a levels-of-processing (LOP) framework. However, patients may rely primarily on familiarity effects, making recognition less sensitive than source monitoring to the strength of the episodic memory trace. The current study investigates whether providing semantic organizational strategies can also normalize patients’ internal source-monitoring performance. Method Sixteen clinically stable medicated patients with schizophrenia and 15 demographically matched healthy controls were asked to identify the source of remembered words following an LOP-encoding paradigm in which they alternated between processing words on a ‘shallow’ perceptual versus a ‘deep’ semantic level. A multinomial analysis provided orthogonal measures of item recognition and source discrimination, and bootstrapping generated variance to allow for parametric analyses. LOP and group effects were tested by contrasting recognition and source-monitoring parameters for words that had been encoded during deep versus shallow processing conditions. Results As in a previous study there were no group differences in LOP effects on recognition performance, with patients and controls benefiting equally from deep versus shallow processing. Although there were no group differences in internal source monitoring, only controls had significantly better performance for words processed during the deep encoding condition. Patient performance did not correlate with clinical symptoms or medication dose. Conclusions Providing a deep processing semantic encoding strategy significantly improved patients’ recognition performance only. The lack of a significant LOP effect on internal source monitoring in patients may reffect subtle problems in the relational binding of semantic information that are independent of strategic memory processes. PMID:16608558
ACS Internal CTE Monitor and Short Darks
NASA Astrophysics Data System (ADS)
Ogaz, Sara
2013-10-01
This is a continuation of Program 13156 and is to be executed once a cycle for internal CTE and short darks, respectively.INTERNAL CTE MONITOR:The charge transfer efficiency {CTE} of the ACS CCD detectors will decline as damage due to on-orbit radiation exposure accumulates. This degradation will be monitored once a cycle to determine the useful lifetime of the CCDs. All the data for this program is acquired using internal targets {lamps} only, so all of the exposures should be taken during Earth occultation time {but not during SAA passages}. This program emulates the ACS pre-flight ground calibration and post-launch SMOV testing {program 8948}, so that results from each epoch can be directly compared. Extended Pixel Edge Response {EPER} data will be obtained over a range of signal levels for the Wide Field Channel {WFC}. The signal levels are 125, 500, 1620, 5000, 10000, and 60000 electrons at gain 2.Since Cycle 18, this monitoring program was reduced {compared to 11881} considering that there is also an external CTE monitoring program.SHORT DARKS:To improve the pixel-based CTE model at signals below 10 DN, short dark frames are needed to obtain a statistically useful sample of clean, warm pixel trails. This program obtains a set of dark frames for each of the following exposure times: 66 s {60 s for some subarrays} and 339 s. These short darks and the 1040 s darks obtained from the CCD Daily Monitor will sample warm and hot pixels over logarithmically increasing brightness. Subarray short darks were added in Cycle 19 to study CTE tails in different subarray readout modes.
Levels-of-processing effect on internal source monitoring in schizophrenia.
Ragland, J Daniel; McCarthy, Erin; Bilker, Warren B; Brensinger, Colleen M; Valdez, Jeffrey; Kohler, Christian; Gur, Raquel E; Gur, Ruben C
2006-05-01
Recognition can be normalized in schizophrenia by providing patients with semantic organizational strategies through a levels-of-processing (LOP) framework. However, patients may rely primarily on familiarity effects, making recognition less sensitive than source monitoring to the strength of the episodic memory trace. The current study investigates whether providing semantic organizational strategies can also normalize patients' internal source-monitoring performance. Sixteen clinically stable medicated patients with schizophrenia and 15 demographically matched healthy controls were asked to identify the source of remembered words following an LOP-encoding paradigm in which they alternated between processing words on a 'shallow' perceptual versus a 'deep' semantic level. A multinomial analysis provided orthogonal measures of item recognition and source discrimination, and bootstrapping generated variance to allow for parametric analyses. LOP and group effects were tested by contrasting recognition and source-monitoring parameters for words that had been encoded during deep versus shallow processing conditions. As in a previous study there were no group differences in LOP effects on recognition performance, with patients and controls benefiting equally from deep versus shallow processing. Although there were no group differences in internal source monitoring, only controls had significantly better performance for words processed during the deep encoding condition. Patient performance did not correlate with clinical symptoms or medication dose. Providing a deep processing semantic encoding strategy significantly improved patients' recognition performance only. The lack of a significant LOP effect on internal source monitoring in patients may reflect subtle problems in the relational binding of semantic information that are independent of strategic memory processes.
Chantler, Tracey; Cheah, Phaik Yeong; Miiro, George; Hantrakum, Viriya; Nanvubya, Annet; Ayuo, Elizabeth; Kivaya, Esther; Kidola, Jeremiah; Kaleebu, Pontiano; Parker, Michael; Njuguna, Patricia; Ashley, Elizabeth; Guerin, Philippe J; Lang, Trudie
2014-01-01
Objectives To evaluate and determine the value of monitoring models developed by the Mahidol Oxford Tropical Research Unit and the East African Consortium for Clinical Research, consider how this can be measured and explore monitors’ and investigators’ experiences of and views about the nature, purpose and practice of monitoring. Research design A case study approach was used within the context of participatory action research because one of the aims was to guide and improve practice. 34 interviews, five focus groups and observations of monitoring practice were conducted. Setting and participants Fieldwork occurred in the places where the monitoring models are coordinated and applied in Thailand, Cambodia, Uganda and Kenya. Participants included those coordinating the monitoring schemes, monitors, senior investigators and research staff. Analysis Transcribed textual data from field notes, interviews and focus groups was imported into a qualitative data software program (NVIVO V. 10) and analysed inductively and thematically by a qualitative researcher. The initial coding framework was reviewed internally and two main categories emerged from the subsequent interrogation of the data. Results The categories that were identified related to the conceptual framing and nature of monitoring, and the practice of monitoring, including relational factors. Particular emphasis was given to the value of a scientific and cooperative style of monitoring as a means of enhancing data quality, trust and transparency. In terms of practice the primary purpose of monitoring was defined as improving the conduct of health research and increasing the capacity of researchers and trial sites. Conclusions The models studied utilise internal and network wide expertise to improve the ethics and quality of clinical research. They demonstrate how monitoring can be a scientific and constructive exercise rather than a threatening process. The value of cooperative relations needs to be given more emphasis in monitoring activities, which seek to ensure that research protects human rights and produces reliable data. PMID:24534257
Kantsevoy, Sergey V; Bitner, Marianne
2013-10-01
Internal hemorrhoids often present with bleeding, prolapse, and other symptoms. Currently used nonsurgical treatment modalities have limited effectiveness and usually require several treatment sessions. To evaluate effectiveness and safety of a novel endoscopic device for nonsurgical treatment of internal hemorrhoids. Retrospective study. Single center. This study involved 23 patients with actively bleeding internal hemorrhoids. The HET Bipolar System is a modified anoscope, with a treatment window, light source, and tissue temperature monitor. The device is inserted into the rectum under direct observation. The tissue carrying superior hemorrhoidal branches and the apex of the internal hemorrhoid is positioned inside the treatment window, clamped with incorporated tissue forceps, and treated with bipolar energy to ligate hemorrhoidal feeding vessels. Rate of hemorrhoidal bleeding after the treatment. The mean age of the patients was 64.3 ± 9.9 years (range 44-79 years). Eleven patients (47.8%) had grade I hemorrhoids and 12 patients (52.2%) had grade II hemorrhoids. In 18 patients (78.3%), treatment with the HET System was performed with the patient under conscious sedation. Five patients (21.7%) were treated without sedation. All patients tolerated treatment without complaints. The average follow-up period was 11.2 ± 4.7 months. No bleeding or prolapse occurred after the procedure in any of the treated patients. Retrospective study. The newly developed HET System is easy to use, safe, and highly effective in eliminating bleeding in grade I and II internal hemorrhoids and prolapse in grade II internal hemorrhoids. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Rapid deployable global sensing hazard alert system
Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M
2015-04-28
A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.
Non-linear motions in reprocessed GPS station position time series
NASA Astrophysics Data System (ADS)
Rudenko, Sergei; Gendt, Gerd
2010-05-01
Global Positioning System (GPS) data of about 400 globally distributed stations obtained at time span from 1998 till 2007 were reprocessed using GFZ Potsdam EPOS (Earth Parameter and Orbit System) software within International GNSS Service (IGS) Tide Gauge Benchmark Monitoring (TIGA) Pilot Project and IGS Data Reprocessing Campaign with the purpose to determine weekly precise coordinates of GPS stations located at or near tide gauges. Vertical motions of these stations are used to correct the vertical motions of tide gauges for local motions and to tie tide gauge measurements to the geocentric reference frame. Other estimated parameters include daily values of the Earth rotation parameters and their rates, as well as satellite antenna offsets. The solution GT1 derived is based on using absolute phase center variation model, ITRF2005 as a priori reference frame, and other new models. The solution contributed also to ITRF2008. The time series of station positions are analyzed to identify non-linear motions caused by different effects. The paper presents the time series of GPS station coordinates and investigates apparent non-linear motions and their influence on GPS station height rates.
Schaunig, Caroline; Kopera, Daisy
2017-05-01
The use of special silk textiles (Dermasilk) has shown positive effects on chronic inflammatory diseases like lichen sclerosus et atrophicus, atopic dermatitis, diabetic ulcerations, and vulvovaginal candidiasis. Wearing T-shirts of this particular fabric could be useful in the management of patients with acne vulgaris on the back and trunk. Dermasilk T-shirts were given to 14 patients with acne vulgaris papulopustulosa on the back. The patients wore these shirts every night for 6 weeks, and their acne lesions were monitored. Dermasilk represents a polymerisate of fibroin, a silk protein, and antimicrobial AEM5772/5, an unsoluble colorless, odorless ammonium with antifungal and antibacterial ability. Photographic documentation before and after 6 weeks showed a clinically significant reduction in acne lesions on the back without any concomitant treatment or change in lifestyle and living conditions. The use of Dermasilk textiles in other subacute-chronic inflammatory skin diseases has shown positive effects. This is the first report on their safe and effective use in the management of acne vulgaris papulopustulosa corporis. © 2017 The International Society of Dermatology.
van Det, M J; Meijerink, W J H J; Hoff, C; Totté, E R; Pierie, J P E N
2009-06-01
With minimally invasive surgery (MIS), a man-machine environment was brought into the operating room, which created mental and physical challenges for the operating team. The science of ergonomics analyzes these challenges and formulates guidelines for creating a work environment that is safe and comfortable for its operators while effectiveness and efficiency of the process are maintained. This review aimed to formulate the ergonomic challenges related to monitor positioning in MIS. Background and guidelines are formulated for optimal ergonomic monitor positioning within the possibilities of the modern MIS suite, using multiple monitors suspended from the ceiling. All evidence-based experimental ergonomic studies conducted in the fields of laparoscopic surgery and applied ergonomics for other professions working with a display were identified by PubMed searches and selected for quality and applicability. Data from ergonomic studies were evaluated in terms of effectiveness and efficiency as well as comfort and safety aspects. Recommendations for individual monitor positioning are formulated to create a personal balance between these two ergonomic aspects. Misalignment in the eye-hand-target axis because of limited freedom in monitor positioning is recognized as an important ergonomic drawback during MIS. Realignment of the eye-hand-target axis improves personal values of comfort and safety as well as procedural values of effectiveness and efficiency. Monitor position is an important ergonomic factor during MIS. In the horizontal plain, the monitor should be straight in front of each person and aligned with the forearm-instrument motor axis to avoid axial rotation of the spine. In the sagittal plain, the monitor should be positioned lower than eye level to avoid neck extension.
Functional seating for school-age children with cerebral palsy: an evidence-based tutorial.
Costigan, F Aileen; Light, Janice
2011-04-01
This tutorial is designed to teach speech-language pathologists (SLPs) best practices to support functional seating of children with cerebral palsy (CP) in the classroom and in school-based therapy sessions. This tutorial teaches SLPs to (a) recognize the positive effects of seating intervention, (b) identify the characteristics of functional seating that may produce these positive effects, and (c) realize their role in supporting functional seating for school-age children with CP. The research reporting positive effects of seating intervention for school-age children with CP is presented according to the International Classification of Functioning, Disability and Health (World Health Organization, 2001). Recommended guidelines for functional seating for school-age children with CP are gleaned from the research evidence. The specific role of the SLP in providing functional seating for children with CP is then discussed. Seating intervention may produce positive body structure and function, activities, and participation effects for school-age children with CP when appropriate equipment is provided for weight bearing, the pelvis is positioned for stability and mobility, and the body is properly aligned. SLPs can support functional seating for school-age children with CP by communicating with professionals with seating expertise and by invoking and monitoring recommended guidelines for children with basic and complex seating needs, respectively.
NASA Astrophysics Data System (ADS)
Eason, Thomas J.; Bond, Leonard J.; Lozev, Mark G.
2015-03-01
Crude oil is becoming more corrosive with higher sulfur concentration, chloride concentration, and acidity. The increasing presence of naphthenic acids in oils with various environmental conditions at temperatures between 150°C and 400°C can lead to different internal degradation morphologies in refineries that are uniform, non-uniform, or localized pitting. Improved corrosion measurement technology is needed to better quantify the integrity risk associated with refining crude oils of higher acid concentration. This paper first reports a consolidated review of corrosion inspection technology to establish the foundation for structural health monitoring of localized internal corrosion in high temperature piping. An approach under investigation is to employ flexible ultrasonic thin-film piezoelectric transducer arrays fabricated by the sol-gel manufacturing process for monitoring localized internal corrosion at temperatures up to 400°C. A statistical analysis of sol-gel transducer measurement accuracy using various time of flight thickness calculation algorithms on a flat calibration block is demonstrated.
The emergence of clinical resistance to tigecycline.
Sun, Yan; Cai, Yun; Liu, Xu; Bai, Nan; Liang, Beibei; Wang, Rui
2013-02-01
Tigecycline (TIG) exhibits broad-spectrum activity against many Gram-positive and Gram-negative pathogens. However, clinical resistance has emerged recently and has been detected following treatment with TIG. This observation suggests that long-term monotherapy may carry a high risk for TIG resistance. TIG resistance is observed most frequently in Acinetobacter baumannii and Enterobacteriaceae, especially in multidrug-resistant strains. Resistance-nodulation-cell division (RND)-type transporters and other efflux pumps may be factors for decreased sensitivity to TIG. Therefore, TIG should be cautiously used in the clinic, and efflux-mediated resistance should be closely monitored in order to prolong the lifespan of this useful antibiotic. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Integrity monitoring of vehicle positioning in urban environment using RTK-GNSS, IMU and speedometer
NASA Astrophysics Data System (ADS)
El-Mowafy, Ahmed; Kubo, Nobuaki
2017-05-01
Continuous and trustworthy positioning is a critical capability for advanced driver assistance systems (ADAS). To achieve continuous positioning, methods such as global navigation satellite systems real-time kinematic (RTK), Doppler-based positioning, and positioning using low-cost inertial measurement unit (IMU) with car speedometer data are combined in this study. To ensure reliable positioning, the system should have integrity monitoring above a certain level, such as 99%. Achieving this level when combining different types of measurements that have different characteristics and different types of errors is a challenge. In this study, a novel integrity monitoring approach is presented for the proposed integrated system. A threat model of the measurements of the system components is discussed, which includes both the nominal performance and possible fault modes. A new protection level is presented to bound the maximum directional position error. The proposed approach was evaluated through a kinematic test in an urban area in Japan with a focus on horizontal positioning. Test results show that by integrating RTK, Doppler with IMU/speedometer, 100% positioning availability was achieved. The integrity monitoring availability was assessed and found to meet the target value where the position errors were bounded by the protection level, which was also less than an alert level, indicating the effectiveness of the proposed approach.
White, Helen E; Hedges, John; Bendit, Israel; Branford, Susan; Colomer, Dolors; Hochhaus, Andreas; Hughes, Timothy; Kamel-Reid, Suzanne; Kim, Dong-Wook; Modur, Vijay; Müller, Martin C; Pagnano, Katia B; Pane, Fabrizio; Radich, Jerry; Cross, Nicholas C P; Labourier, Emmanuel
2013-06-01
Current guidelines for managing Philadelphia-positive chronic myeloid leukemia include monitoring the expression of the BCR-ABL1 (breakpoint cluster region/c-abl oncogene 1, non-receptor tyrosine kinase) fusion gene by quantitative reverse-transcription PCR (RT-qPCR). Our goal was to establish and validate reference panels to mitigate the interlaboratory imprecision of quantitative BCR-ABL1 measurements and to facilitate global standardization on the international scale (IS). Four-level secondary reference panels were manufactured under controlled and validated processes with synthetic Armored RNA Quant molecules (Asuragen) calibrated to reference standards from the WHO and the NIST. Performance was evaluated in IS reference laboratories and with non-IS-standardized RT-qPCR methods. For most methods, percent ratios for BCR-ABL1 e13a2 and e14a2 relative to ABL1 or BCR were robust at 4 different levels and linear over 3 logarithms, from 10% to 0.01% on the IS. The intraassay and interassay imprecision was <2-fold overall. Performance was stable across 3 consecutive lots, in multiple laboratories, and over a period of 18 months to date. International field trials demonstrated the commutability of the reagents and their accurate alignment to the IS within the intra- and interlaboratory imprecision of IS-standardized methods. The synthetic calibrator panels are robust, reproducibly manufactured, analytically calibrated to the WHO primary standards, and compatible with most BCR-ABL1 RT-qPCR assay designs. The broad availability of secondary reference reagents will further facilitate interlaboratory comparative studies and independent quality assessment programs, which are of paramount importance for worldwide standardization of BCR-ABL1 monitoring results and the optimization of current and new therapeutic approaches for chronic myeloid leukemia. © 2013 American Association for Clinical Chemistry.
NASA Astrophysics Data System (ADS)
Laban, Shaban; El-Desouky, Ali
2010-05-01
The heterogeneity of the distributed processing systems, monitored data and resources is an obvious challenge in monitoring the data of International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban Treaty organization (CTBTO). Processing engineers, analysts, operators and other interested parties seek for intelligent tools and software that hide the underlying complexity of the systems, allowing them to manage the operation and monitoring the systems at a higher level, focusing on what the expected behavior and results should be instead of how to specifically achieve it. Also, it is needed to share common understanding of the structure of organization information, data, and products among staff, software agents, and policy making organs. Additionally, introducing new monitoring object or system should not complicate the overall system and should be feasible. An ontologybased approach is presented in this paper aiming to support monitoring real-time data processing and supervising the various system resources, focusing on integrating and sharing same knowledge and status information of the system among different environments. The results of a prototype framework is presented and analyzed.
Adam J. Gaylord; Dana M. Sanchez
2014-01-01
Direct behavioral observations of multiple free-ranging animals over long periods of time and large geographic areas is prohibitively difficult. However, recent improvements in technology, such as Global Positioning System (GPS) collars equipped with motion-sensitive activity monitors, create the potential to remotely monitor animal behavior. Accelerometer-equipped...
The Environmental Technology Verification report discusses the technology and performance of a gaseous-emissions monitoring system for large, natural-gas-fired internal combustion engines. The device tested is the Parametric Emissions Monitoring System (PEMS) manufactured by ANR ...
Establishment of the New Ecuadorian Solar Physics Phenomena Division
NASA Astrophysics Data System (ADS)
Lopez, E. D.
2014-02-01
Crucial physical phenomena occur in the equatorial atmosphere and ionosphere, which are currently understudied and poorly understood. Thus, scientific campaigns for monitoring the equatorial region are required in order to provide the necessary data for the physical models. Ecuador is located in strategic geographical position where these studies can be performed, providing quality data for the scientific community working in understanding the nature of these physical systems. The Quito Astronomical Observatory of National Polytechnic School is moving in this direction by promoting research in space sciences for the study of the equatorial zone. With the participation and the valuable collaboration of international initiatives such us AWESOME, MAGDAS, SAVNET and CALLISTO, the Quito Observatory is establishing a new space physics division on the basis of the International Space Weather Initiative. In this contribution, the above initiative is presented by inviting leaders of other scientific projects to deploy its instruments and to work with us providing the necessary support to the creation of this new strategic research center
Obaidat, Mohammad M; Massadeh, Adnan M; Al-Athamneh, Ahmad M; Jaradat, Qasem M
2015-04-01
This study determined the levels of As, Cu, Pb, and Cd in fish from Red Sea, Arabian Sea, and Indian Ocean by graphite furnace atomic absorption spectrophotometry. Metal levels were compared with international standards. The levels among fish types and origin, the relationship among metals, and the correlation between the levels and fish size were statistically tested. Fish type and origin significantly affected the levels. None of the fish contained As, Cu, and Pb above the FAO and EU codes. However, Cd exceeded the Jordanian, FAO, and EC codes from the three origins. As and Cd positively correlated with each other in Arabian Sea fish. As and Pb correlated negatively, but Cu and Cd did not correlate with fish size. This study indicates that Cd is common in fish from the three origins regardless the fish size. This warrants continuous monitoring for heavy metals, especially Cd, in internationally traded fish.
International conference on the role of the polar regions in global change: Proceedings. Volume 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weller, G.; Wilson, C.L.; Severin, B.A.B.
1991-12-01
The International Conference on the Role of the Polar Regions in Global Change took place on the campus of the University of Alaska Fairbanks on June 11--15, 1990. The goal of the conference was to define and summarize the state of knowledge on the role of the polar regions in global change, and to identify gaps in knowledge. To this purpose experts in a wide variety of relevant disciplines were invited to present papers and hold panel discussions. While there are numerous conferences on global change, this conference dealt specifically with the polar regions which occupy key positions in themore » global system. These two volumes of conference proceedings include papers on (1) detection and monitoring of change; (2) climate variability and climate forcing; (3) ocean, sea ice, and atmosphere interactions and processes; and (4) effects on biota and biological feedbacks; (5) ice sheet, glacier and permafrost responses and feedbacks, (6) paleoenvironmental studies; and, (7) aerosol and trace gases.« less
Kuzay, T.M.; Shu, D.
1995-02-07
A photon beam position monitor is disclosed for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade ''shadowing''. Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation. 18 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pettersson, N; Murphy, J; Simpson, D
Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT,more » simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing signal has been observed to be about 1 mm in four pancreas SBRT patients, leading to small dose distribution impact. Pettersson and Cervino are funded by a Varian Medical Systems grant.« less
The Relationship Between Attachment Styles, Self-Monitoring and Cybercrime in Social Network Users.
Yaghoobi, Abolghasem; Mohammadzade, Serwa; Chegini, Ali Asghar; Yarmohammadi Vasel, Mosaeib; Zoghi Paidar, Mohammad Reza
2016-09-01
The anonymity in the cyberspace environment, as well as the rapid advent of and improvements to online activities has increased cybercrime. The aim of this paper was to survey the relationship between attachment styles, self-monitoring and cybercrime in social network users. The Collins and Read Adult Attachment Scale, and the Snyder self-monitoring and cybercrime scales were sent to 500 social network users. Of these, 203 users (103 men and 100 women) filled out the questionnaires. The results showed that women achieved higher scores in self-monitoring and the anxious attachment style, and men achieved higher scores in cybercrime and the anxious attachment style. There was a negative correlation between self-monitoring and cybercrime, and the anxious attachment style had a positive correlation with cybercrime and a negative correlation with self-monitoring. The secure attachment style had a positive correlation with self-monitoring and a negative correlation with cybercrime. The dependent attachment style had a positive correlation with self-monitoring and a negative correlation with cybercrime. All correlations were significant. Attachment styles have significant relationships with both self-monitoring and cybercrime. Self-monitoring and attachment styles are significant predictors of cybercrimes.
The Relationship Between Attachment Styles, Self-Monitoring and Cybercrime in Social Network Users
Yaghoobi, Abolghasem; Mohammadzade, Serwa; Chegini, Ali Asghar; Yarmohammadi Vasel, Mosaeib; Zoghi Paidar, Mohammad Reza
2016-01-01
Background The anonymity in the cyberspace environment, as well as the rapid advent of and improvements to online activities has increased cybercrime. Objectives The aim of this paper was to survey the relationship between attachment styles, self-monitoring and cybercrime in social network users. Patients and Methods The Collins and Read Adult Attachment Scale, and the Snyder self-monitoring and cybercrime scales were sent to 500 social network users. Of these, 203 users (103 men and 100 women) filled out the questionnaires. Results The results showed that women achieved higher scores in self-monitoring and the anxious attachment style, and men achieved higher scores in cybercrime and the anxious attachment style. There was a negative correlation between self-monitoring and cybercrime, and the anxious attachment style had a positive correlation with cybercrime and a negative correlation with self-monitoring. The secure attachment style had a positive correlation with self-monitoring and a negative correlation with cybercrime. The dependent attachment style had a positive correlation with self-monitoring and a negative correlation with cybercrime. All correlations were significant. Conclusions Attachment styles have significant relationships with both self-monitoring and cybercrime. Self-monitoring and attachment styles are significant predictors of cybercrimes. PMID:27818964
Carr, Robert; Fanti, Stefano; Paez, Diana; Cerci, Juliano; Györke, Tamás; Redondo, Francisca; Morris, Tim P; Meneghetti, Claudio; Auewarakul, Chirayu; Nair, Reena; Gorospe, Charity; Chung, June-Key; Kuzu, Isinsu; Celli, Monica; Gujral, Sumeet; Padua, Rose Ann; Dondi, Maurizio
2014-12-01
The International Atomic Energy Agency sponsored a large, multinational, prospective study to further define PET for risk stratification of diffuse large B-cell lymphoma and to test the hypothesis that international biological diversity or diversity of healthcare systems may influence the kinetics of treatment response as assessed by interim PET (I-PET). Cancer centers in Brazil, Chile, Hungary, India, Italy, the Philippines, South Korea, and Thailand followed a common protocol based on treatment with R-CHOP (cyclophosphamide, hydroxyadriamycin, vincristine, prednisolone with rituximab), with I-PET after 2-3 cycles of chemotherapy and at the end of chemotherapy scored visually. Two-year survivals for all 327 patients (median follow-up, 35 mo) were 79% (95% confidence interval [CI], 74%-83%) for event-free survival (EFS) and 86% (95% CI, 81%-89%) for overall survival (OS). Two hundred ten patients (64%) were I-PET-negative, and 117 (36%) were I-PET-positive. Two-year EFS was 90% (95% CI, 85%-93%) for I-PET-negative and 58% (95% CI, 48%-66%) for I-PET-positive, with a hazard ratio of 5.31 (95% CI, 3.29-8.56). Two-year OS was 93% (95% CI, 88%-96%) for I-PET-negative and 72% (95% CI, 63%-80%) for I-PET-positive, with a hazard ratio of 3.86 (95% CI, 2.12-7.03). On sequential monitoring, 192 of 312 (62%) patients had complete response at both I-PET and end-of-chemotherapy PET, with an EFS of 97% (95% CI, 92%-98%); 110 of these with favorable clinical indicators had an EFS of 98% (95% CI, 92%-100%). In contrast, the 107 I-PET-positive cases segregated into 2 groups: 58 (54%) achieved PET-negative complete remission at the end of chemotherapy (EFS, 86%; 95% CI, 73%-93%); 46% remained PET-positive (EFS, 35%; 95% CI, 22%-48%). Heterogeneity analysis found no significant difference between countries for outcomes stratified by I-PET. This large international cohort delivers 3 novel findings: treatment response assessed by I-PET is comparable across disparate healthcare systems, secondly a negative I-PET findings together with good clinical status identifies a group with an EFS of 98%, and thirdly a single I-PET scan does not differentiate chemoresistant lymphoma from complete response and cannot be used to guide risk-adapted therapy. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
NASA Astrophysics Data System (ADS)
Aishlin, P. S.; Selker, J. S.
2015-12-01
Climate change understanding and impacts vary by community, yet the global nature of climate change requires international collaboration to address education, monitoring, adaptation and mitigation needs. We propose that effective climate change monitoring and education can be accomplished via student-led local and international community partnerships. By empowering students as community leaders in climate-environmental monitoring and education, as well as exploration of adaptation/mitigation needs, well-informed communities and young leadership are developed to support climate change science moving forward. Piloted 2013-2015, the SLICEIT1 program partnered with TAHMO2 to connect student leaders in North America, Europe and Africa. At the international level, schools in the U.S.A and Netherlands were partnered with schools in Ghana, Kenya, and Uganda for science and cultural exchange. Each school was equipped with a climate or other environmental sensing system, real-time data publication and curricula for both formal and informal science, technology, engineering and math education and skill development. African counterparts in TAHMO's School-2-School program collect critically important data for enhanced on-the-ground monitoring of weather conditions in data-scarce regions of Africa. In Idaho, student designed, constructed and installed weather stations provide real time data for classroom and community use. Student-designed formal educational activities are disseminated to project partners, increasing hands-on technology education and peer-based learning. At the local level, schools are partnered with a local agency, research institute, nonprofit organization, industry and/or community partner that supplies a climate science expert mentor to SLICEIT program leaders and teachers. Mentor engagement is facilitated and secured by program components that directly benefit the mentor's organization and local community via climate/environment monitoring, student workforce skill development, community education, and/or adaptation/mitigation activities. Students are motivated by advanced real-world skill development, leadership opportunity, internship, community service and opportunity for international peer communication.
Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang
2017-12-01
The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.
Shukla, K; Shahane, S; D’Souza, W
2017-01-01
Background: Considering a huge working population in health sector faced with stressful work life, limited autonomy in work and declining work contentment calls for an overemphasis on evaluating and monitoring their satisfaction associated with work-related quality of life (WRQoL). This study evaluates WRQoL of hospital employees and validates the bilingual (English and Marathi) version of WRQoL scale. Methods: The study was conducted during March–April’2014 on employees of a corporate hospital of Pune, India after ethical approval and informed consent from employees. The bilingual WRQoL scale has been tested for reliability and validity, and WRQoL scores have been reported. Results: A total of 132 hospital employees (mean age 31 [±8] years, 55% males) who participated in the study reported overall moderate WRQoL scores. The scale showed high internal consistency (Cronbach's alpha = 0.82, P < 0.0001) and moderate to high validity. WRQoL did not significantly vary across marital status, family size, and gender. “Stress at work” score of WRQoL increased with age of employees. Higher work experience, employment at higher positions and those working in clinical and diagnostic departments reported a higher WRQoL. Conclusion: WRQoL scale is a reliable and valid instrument. Better WRQoL in employees placed in higher organizational positions indicates a need for focused measures to enhance WRQoL of employees in lower hierarchical levels, especially in control at work and home life interface domains. WRQoL needs regular monitoring for employees in lower positions and aging employees. PMID:27779152
Thappali, Satheeshmanikandan R. S.; Varanasi, Kanthikiran; Veeraraghavan, Sridhar; Arla, Rambabu; Chennupati, Sandhya; Rajamanickam, Madheswaran; Vakkalanka, Swaroop; Khagga, Mukkanti
2012-01-01
A new method for the simultaneous determination of celecoxib, erlotinib, and its active metabolite desmethyl-erlotinib (OSI-420) in rat plasma, by liquid chromatography/tandem mass spectrometry with positive/negative ion-switching electrospray ionization mode, was developed and validated. Protein precipitation with methanol was selected as the method for preparing the samples. The analytes were separated on a reverse-phase C18 column (50mm×4.6mm i.d., 3μ) using methanol: 2 mM ammonium acetate buffer, and pH 4.0 as the mobile phase at a flow rate 0.8 mL/min. Sitagliptin and Efervirenz were used as the internal standards for quantification. The determination was carried out on a Theremo Finnigan Quantam ultra triple-quadrupole mass spectrometer, operated in selected reaction monitoring (SRM) mode using the following transitions monitored simultaneously: positive m/z 394.5→278.1 for erlotinib, m/z 380.3→278.1 for desmethyl erlotinib (OSI-420), and negative m/z −380.1→ −316.3 for celecoxib. The limits of quantification (LOQs) were 1.5 ng/mL for Celecoxib, erlotinib, and OSI-420. Within- and between-day accuracy and precision of the validated method were within the acceptable limits of < 15% at all concentrations. The quantitation method was successfully applied for the simultaneous estimation of celecoxib, erlotinib, and desmethyl erlotinib in a pharmacokinetic study in Wistar rats. PMID:23008811
Lima, Viviane Dias; Andia, Irene; Kabakyenga, Jerome; Mbabazi, Pamela; Emenyonu, Nneka; Patterson, Thomas L.; Hogg, Robert S.; Bangsberg, David R.
2013-01-01
The objective of this study was to develop a reliable HAART optimism scale among HIV-positive women in Uganda and to test the scale’s validity against measures of fertility intentions, sexual activity, and unprotected sexual intercourse. We used cross-sectional survey data of 540 women (18–50 years) attending Mbarara University’s HIV clinic in Uganda. Women were asked how much they agreed or disagreed with 23 statements about HAART. Data were subjected to a principal components and factor analyses. Subsequently, we tested the association between the scale and fertility intentions and sexual behaviour using Wilcoxon rank sum test. Factor analysis yielded three factors, one of which was an eight-item HAART optimism scale with moderately high internal consistency (α = 0.70). Women who reported that they intended to have (more) children had significantly higher HAART optimism scores (median = 13.5 [IQR: 12–16]) than women who did not intend to have (more) children (median = 10.5 [IQR: 8–12]; P <0.0001). Similarly, women who were sexually active and who reported practicing unprotected sexual intercourse had significantly higher HAART optimism scores than women who were sexually abstinent or who practiced protected sexual intercourse. Our reliable and valid scale, termed the Women’s HAART Optimism Monitoring and EvaluatioN scale (WHOMEN’s scale), may be valuable to broader studies investigating the role of HAART optimism on reproductive intentions and sexual behaviours of HIV-positive women in high HIV prevalence settings. PMID:19387819
Popkirov, Stoyan; Jungilligens, Johannes; Grönheit, Wenke; Wellmer, Jörg
2017-08-01
Psychogenic nonepileptic seizures (PNES) can remain undiagnosed for many years, leading to unnecessary medication and delayed treatment. A recent report by the International League Against Epilepsy Nonepileptic Seizures Task Force recommends a staged approach to the diagnosis of PNES (LaFrance, et al., 2013). We aimed to investigate its practical utility, and to apply the proposed classification to evaluate the role of long-term video-EEG monitoring (VEEG) and suggestive seizure induction (SSI) in PNES workup. Using electronic medical records, 122 inpatients (mean age 36.0±12.9years; 68% women) who received the diagnosis of PNES at our epilepsy center during a 4.3-year time period were included. There was an 82.8% agreement between diagnostic certainty documented at discharge and that assigned retroactively using the Task Force recommendations. In a minority of cases, having used the Task Force criteria could have encouraged the clinicians to give more certain diagnoses, exemplifying the Task Force report's utility. Both VEEG and SSI were effective at supporting high level diagnostic certainty. Interestingly, about one in four patients (26.2%) had a non-diagnostic ("negative") VEEG but a positive SSI. On average, this subgroup did not have significantly shorter mean VEEG recording times than VEEG-positive patients. However, VEEG-negative/SSI-positive patients had a significantly lower habitual seizure frequency than their counterparts. This finding emphasizes the utility of SSI in ascertaining the diagnosis of PNES in patients who do not have a spontaneous habitual event during VEEG due to, for example, low seizure frequency. Copyright © 2017 Elsevier Inc. All rights reserved.
Damschroder, Laura J; Goodrich, David E; Kim, Hyungjin Myra; Holleman, Robert; Gillon, Leah; Kirsh, Susan; Richardson, Caroline R; Lutes, Lesley D
2016-09-01
Practical and valid instruments are needed to assess fidelity of coaching for weight loss. The purpose of this study was to develop and validate the ASPIRE Coaching Fidelity Checklist (ACFC). Classical test theory guided ACFC development. Principal component analyses were used to determine item groupings. Psychometric properties, internal consistency, and inter-rater reliability were evaluated for each subscale. Criterion validity was tested by predicting weight loss as a function of coaching fidelity. The final 19-item ACFC consists of two domains (session process and session structure) and five subscales (sets goals and monitor progress, assess and personalize self-regulatory content, manages the session, creates a supportive and empathetic climate, and stays on track). Four of five subscales showed high internal consistency (Cronbach alphas > 0.70) for group-based coaching; only two of five subscales had high internal reliability for phone-based coaching. All five sub-scales were positively and significantly associated with weight loss for group- but not for phone-based coaching. The ACFC is a reliable and valid instrument that can be used to assess fidelity and guide skill-building for weight management interventionists.
Seitz, J.C.; Pasteris, J.D.; Chou, I.-Ming
1996-01-01
Raman spectral parameters were determined for the v1 band of CH4 and the v1 and 2v2 bands (Fermi diad) of CO2 in pure CO2 and CO2-CH4 mixtures at pressures up to 700 bars and room temperature. Peak position, area, height, and width were investigated as functions of pressure and composition. The peak positions of the CH4 and CO2 bands shift to lower relative wavenumbers as fluid pressure is increased. The peak position of the lower-wavenumber member of the Fermi diad for CO2 is sensitive to fluid composition, whereas the peak positions of the CH4 band and the upper Fermi diad member for CO2 are relatively insensitive in the CO2-CH4 system. The magnitude of the shifts in each of the three peak positions (as a function of pressure) is sufficient to be useful as a monitor of fluid pressure. The relative molar proportions in a CO2-CH4 mixture may be determined from the peak areas: the ratio of the peak areas of the CH4 band and the CO2 upper Fermi diad member is very sensitive to composition, whereas above about 100 bars, it is insensitive to pressure. Likewise, the peak height ratio is very sensitive to composition but also to fluid pressure. The individual peak widths of CO2 and CH4, as well as the ratios of the widths of the CH4 peak to the CO2 peaks are a sensitive function of pressure and, to a lesser extent, composition. Thus, upon determination of fluid composition, the peak width ratios may be used as a monitor of fluid pressure. The application of these spectral parameters to a suite of natural CO2-CH4 inclusions has yielded internally-consistent, quantitative determinations of the fluid composition and density.
Lo Presti, D; Massaroni, C; Saccomandi, P; Caponero, M A; Formica, D; Schena, E
2017-07-01
The interest on wearable textiles to monitor vital signs is growing in the research field and clinical scenario related to the increasing demands of long-term monitoring. Despite several smart textile-based solutions have been proposed for assessing the respiratory status, only a limited number of devices allow the respiratory monitoring in a harsh environment or in different positions of the human body. In this paper, we investigated the performances of a smart textile for respiratory rate monitoring characterized by 12 fiber optic sensors (i.e., fiber Bragg grating) placed on specific landmarks for compartmental analysis of the chest wall movements during quiet breathing. We focused on the analysis of the influence of sensor position on both peak-to-peak amplitude of sensors output and accuracy of respiratory rate measurements. This analysis was performed on two participants, who wore the textile in two positions (i.e., standing and supine). Bland-Altman analysis on respiratory rate showed promising results (better than 0.3 breaths per minute). Referring to the peak-to-peak output amplitude, the abdomen compartment showed the highest excursions in both the enrolled participants and positions. Our findings open up new approaches to design and develop smart textile for respiratory rate monitoring.
Ngo, Carine; Laé, Marick; Ratour, Julia; Hamel, Frédérique; Taris, Corinne; Caly, Martial; Le Cunff, Annie; Reyal, Fabien; Kirova, Youlia; Pierga, Jean-Yves; Vincent-Salomon, Anne
The implementation of an internal quality control is mandatory to guarantee the accuracy of HER2 status in invasive breast cancers. To evaluate the impact of our quality control assurance on HER2 status results in invasive breast carcinomas from 2008 to 2014. HER2 status was determined by immunohistochemistry as the first-line indication, completed by fluorescence in situ hybridization (FISH) for scores 2+ by immunohistochemistry. Internal quality control of HER2 status relied on the standardization of pre-analytical phases, the use of external controls with a known number of HER2 gene copies determined by FISH and continued monitoring of concordance between immunohistochemistry and FISH. The proportion of HER2-positive cases corresponding to scores 3+ by immunohistochemistry and 2+ amplified by FISH varied from 10.6% to 13.8% (median of 11.3%). The proportion of scores 2+ amplified by FISH varied from 13.3% to 32.7% during period of study. The rate of concordance between FISH and immunohistochemistry for score 0/1+ and 3+ cases were≥97%. Eight among 12 discordant cases were false positive resulting from errors in interpretation of immunohistochemistry (score 2+ instead of 3+). Calibration of immunohistochemistry on FISH for HER2 status contributes to limit variability of immunohistochemistry results due to technical issues or interpretation. The implementation of an external control of score 3+ on each slide enables accurate interpretation of score 2+ and 3+ by immunohistochemistry. Copyright © 2017 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.
Sun, Xian; Yu, Ri-Qing; Zhang, Mei; Zhang, Xiyang; Chen, Xi; Xiao, Yousheng; Ding, Yulong; Wu, Yuping
2017-12-15
Trace element accumulation in the epidermis of cetaceans has been less studied. This study explored the feasibility of using epidermis as a surrogate tissue to evaluate internal contaminant burdens in Indo-Pacific humpback dolphin (Sousa chinensis). Eleven trace elements were analyzed in the epidermis, muscle and liver tissues from 46 individuals of dolphins stranded along the Pearl River Estuary (PRE) coast between 2007 and 2013. Trace elemental concentrations varied among the three tissues, generally with the highest concentrations found in liver tissues and lowest in the epidermis (except Zn, As, and Pb). Zn concentration in the epidermis was the highest among all tissues, indicating that Zn could be an important element for the epidermis physiology. High concentrations of Hg and Cr in liver were likely due to an excessive intake by dolphins which consumed high Hg and Cr contaminated fishes in the PRE. Hg concentrations in epidermis and muscle tissues were significantly higher in the females than in males. Concentrations of V and Pb in liver, Se and Cd in both muscle and liver, and As and Hg in all tissue samples showed significantly positive relationships with body length. Hepatic Cu concentrations were significantly negatively correlated with the body length. Hg and As concentrations in epidermis showed significantly positive correlations with those in liver tissues. Thus this study proposed that epidermis could be used as a non-invasive monitoring tissue to evaluate Hg and As bioaccumulation in internal tissues of Indo-Pacific humpback dolphins populations. Copyright © 2017 Elsevier B.V. All rights reserved.
Kulaga, Zbigniew; Litwin, Mieczysław; Tkaczyk, Marcin; Rózdzyńska, Agnieszka; Barwicka, Katarzyna; Grajda, Aneta; Swiader, Anna; Gurzkowska, Beata; Napieralska, Ewelina; Pan, Huiqi
2010-03-04
The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used.
2010-01-01
Background The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Methods Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Results Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. Conclusions In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used. PMID:20199693
Alexandre, Dellal; da Silva, Cristiano Diniz; Hill-Haas, Stephen; Wong, Del P; Natali, Antonio J; De Lima, Jorge R P; Bara Filho, Mauricio G B; Marins, Joao J C B; Garcia, Emerson Silami; Karim, Chamari
2012-10-01
The identification of physiological loads imposed by soccer training or match play reveals essential information, which may help improve training and recovery strategies. Until today, the use of heart rate (HR) monitoring is not standardized in soccer. Thus, the aim of this review was to analyze, determine and compare the exercise intensity (EI) monitored by HR in professional, youth, and recreational soccer players during matches and training sessions using a meta-analysis. Heart rate is one of the most common physiological variables used to determine exercise internal training load. The mean EI recorded during competitive matches was described as 70-80% of VO2max or 80-90% of maximal heart rate (HRmax), independent of the playing level. With respect to HR training zones, approximately 65% of the total match duration is spent at intensity of 70-90% HRmax and rarely below 65% HRmax. However, although HRmax is mostly employed in the literature, monitoring EI should be expressed in relation to reserve heart rate, as it was described as a more reliable indicator of HR, allowing interindividual comparisons. The HR response according to the playing position indicates that midfielders are characterized by the highest EI, followed by forwards and fullbacks. Moreover, in the second half of the match, the EI is lower than that observed during the first half; this reduction could be correlated with the level of the player's physical conditioning. Consequently, coaches may favor the use of interval training or small-sided training games because these are shown to improve both aerobic capacity and the ability to repeat high-intensity actions. Small-sided games allow reaching similar HR responses to those found during interval training and match play but with greater heterogeneity values. Future investigations should include a larger sample of players with special reference to playing position and the expression of EI in percentage of the reserve heart rate, analyzing the possible intergender differences in HR response.
INTERNATIONAL SOURCE WATER TOXICITY MONITORING CONSORTIUM
Many researchers in the field of time-relevant, on-line toxicity monitors for source water protection believe that some mechanism to guide and prioritize research in this emerging field would be beneficial. On-line toxicity monitors are tools designed to screen water quality and ...
Wf/pc Cycle 2 Calibration: Rapid Internal Monitor - Part 2
NASA Astrophysics Data System (ADS)
MacKenty, John
1991-07-01
This test is to take repeated internal flats to test for contamination buildup on the optical surfaces or the reappearance of QEH. Part 1: INTFLATS in F555W are obtained every 4 days in both WFC and PC to check for measles or daisies and to monitor scattered light. Part 2: Sequential INTFLATS in F439W with PC are obtained every 7 days to check for QEH.
Wf/pc Cycle 1 Calibration: Rapid Internal Monitor
NASA Astrophysics Data System (ADS)
MacKenty, John
1990-12-01
This test is to take repeated internal flats to test for contamination buildup on the optical surfaces or the reappearance of QEH. Part 1: INTFLATS in F555W are obtained every 4 days in both WFC and PC to check for measles or daisies and to monitor scattered light. Part 2: Sequential INTFLATS in F439W with PC are obtained every 7 days to check for QEH.
Wf/pc Cycle 3 Calibration: Rapid Internal Monitor
NASA Astrophysics Data System (ADS)
MacKenty, John
1992-06-01
This test is to take repeated internal flats to test for contamination buildup on the optical surfaces or the reappearance of QEH. Part 1: INTFLATS in F555W are obtained every 4 days in both WFC and PC to check for measles or daisies and to monitor scattered light. Part 2: Sequential INTFLATS in F439W with PC are obtained every 7 days to check for QEH.
Wf/pc Cycle 2 Calibration: Rapid Internal Monitor
NASA Astrophysics Data System (ADS)
MacKenty, John
1991-07-01
This test is to take repeated internal flats to test for contamination buildup on the optical surfaces or the reappearance of QEH. Part 1: INTFLATS in F555W are obtained every 4 days in both WFC and PC to check for measles or daisies and to monitor scattered light. Part 2: Sequential INTFLATS in F439W with PC are obtained every 7 days to check for QEH.
Wf/pc Cycle 3 Calibration: Rapid Internal Monitor - Part 2
NASA Astrophysics Data System (ADS)
MacKenty, John
1992-06-01
This test is to take repeated internal flats to test for contamination buildup on the optical surfaces or the reappearance of QEH. Part 1: INTFLATS in F555W are obtained every 4 days in both WFC and PC to check for measles or daisies and to monitor scattered light. Part 2: Sequential INTFLATS in F439W with PC are obtained every 7 days to check for QEH.
Experimentally derived resistivity for dielectric samples from the CRRES internal discharge monitor
NASA Technical Reports Server (NTRS)
Green, Nelson W.; Frederickson, A. Robb; Dennison, J. R.
2005-01-01
Resistivity values were experimentally determined using charge storage methods for six samples remaining from the construction of the Internal Discharge Monitor (IDM) flown on the Combined Release and Radiation Effects Satellite (CRRES). Three tests were performed over a period of four to five weeks each in a vacuum of -5x10^-6 torr with an average temperature of -25 (deg)C to simulate a space environment.
Fink, Günther; Levenson, Rachel; Tembo, Sarah; Rockers, Peter C
2017-10-01
Background: Despite the continued high prevalence of faltering growth, height monitoring remains limited in many low- and middle-income countries. Objective: The objective of this study was to test whether providing parents with information on their child's height can improve children's height and developmental outcomes. Design: Villages in Chipata District, Zambia ( n = 127), were randomly assigned with equal probability to 1 of 3 groups: home-based growth monitoring (HBGM), community-based growth monitoring including nutritional supplementation for children with stunted growth (CBGM+NS), and control. Primary study outcomes were individual height-for-age z score (HAZ) and overall child development assessed with the International Fetal and Newborn Growth Consortium for the 21st Century Neurodevelopment Assessment tool. Secondary outcomes were weight-for-age z score (WAZ), protein consumption, breastfeeding, and general dietary diversity. Results: We enrolled a total of 547 children with a median age of 13 mo at baseline. Estimated mean difference (β) in HAZ was 0.127 (95% CI: -0.107, 0.361) for HBGM and -0.152 (95% CI: -0.341, 0.036) for CBGM+NS. HBGM had no impact on child development [β: -0.017 (95% CI: -0.133, 0.098)]; CBGM+NS reduced overall child development scores by -0.118 SD (95% CI: -0.230, -0.006 SD). Both interventions had larger positive effects among children with stunted growth at baseline, with estimated interaction effects of 0.503 (95% CI: 0.160, 0.846) and 0.582 (95% CI: 0.134, 1.030) for CBGM+NS and HBGM, respectively. HBGM increased mean WAZ [β = 0.183 (95% CI: 0.037, 0.328)]. Both interventions improved parental reports of children's protein intake. Conclusions: The results from this trial suggest that growth monitoring has a limited effect on children's height and development, despite improvements in self-reported feeding practices. HBGM had modest positive effects on children with stunted growth. Given its relatively low cost, this intervention may be a cost-effective tool for increasing parental efforts toward reducing children's physical growth deficits. This trial was registered at clinicaltrials.gov as NCT02242539.
A mobile phone based alarm system for supervising vital parameters in free moving rats.
Kellermann, Kristine; Kreuzer, Matthias; Omerovich, Adem; Hoetzinger, Franziska; Kochs, Eberhard F; Jungwirth, Bettina
2012-02-23
Study protocols involving experimental animals often require the monitoring of different parameters not only in anesthetized, but also in free moving animals. Most animal research involves small rodents, in which continuously monitoring parameters such as temperature and heart rate is very stressful for the awake animals or simply not possible. Aim of the underlying study was to monitor heart rate, temperature and activity and to assess inflammation in the heart, lungs, liver and kidney in the early postoperative phase after experimental cardiopulmonary bypass involving 45 min of deep hypothermic circulatory arrest in rats. Besides continuous monitoring of heart rate, temperature and behavioural activity, the main focus was on avoiding uncontrolled death of an animal in the early postoperative phase in order to harvest relevant organs before autolysis would render them unsuitable for the assessment of inflammation. We therefore set up a telemetry-based system (Data Science International, DSI™) that continuously monitored the rat's temperature, heart rate and activity in their cages. The data collection using telemetry was combined with an analysis software (Microsoft excel™), a webmail application (GMX) and a text message-service. Whenever an animal's heart rate dropped below the pre-defined threshold of 150 beats per minute (bpm), a notification in the form of a text message was automatically sent to the experimenter's mobile phone. With a positive predictive value of 93.1% and a negative predictive value of 90.5%, the designed surveillance and alarm system proved a reliable and inexpensive tool to avoid uncontrolled death in order to minimize suffering and harvest relevant organs before autolysis would set in. This combination of a telemetry-based system and software tools provided us with a reliable notification system of imminent death. The system's high positive predictive value helped to avoid uncontrolled death and facilitated timely organ harvesting. Additionally we were able to markedly reduce the drop out rate of experimental animals, and therefore the total number of animals used in our study. This system can be easily adapted to different study designs and prove a helpful tool to relieve stress and more importantly help to reduce animal numbers.
NASA Astrophysics Data System (ADS)
Muller, C.; Moreau, D., Sr.; Pandey, P. K.; Crosby, N. B.
2014-12-01
The Belgian User Support and Operations Centre (B.USOC) is an operational centre managing technological and scientific payloads on the International Space Station (ISS). B.USOC is the Facility Responsible Centre (FRC) for the European Space Agency's (ESA) Atmosphere-Space Interactions Monitor (ASIM) payload and also manages the Scientific Mission Centre of the Centre National d'Etudes Spatiales (CNES) PICARD satellite that monitors solar activity, among various other space missions. In this respect, B.USOC is ideally positioned to manage possible synergies between ASIM, the satellite TARANIS (Tool for the Analysis of RAdiation from lightNIng and Sprites), other space missions and ground-based networks. The ASIM mission (Neubert, 2009) consists of a package of two nadir instruments: one for the visible spectrum and another for X-ray and gamma-ray frequencies. In the normal operating mode "trigger mode" both instruments continuously measure, but, do not record data below certain thresholds. Another mode is a "timed mode", where, during a certain time the observations are recorded even in the absence of triggers. The "timed mode" demands a lot of flexibility from both scientific teams and B.USOC, as, ASIM's main targets of investigation (sprites and elves) are related to intense thunderstorms and thus, require reliable meteorological forecasts in the entire range of ISS latitudes. Moreover, ASIM is sensitive to a large number of phenomena of which most have a direct relationship with solar activity and therefore would probably need support from the ESA SSA (Space Situational Awareness) Space Weather Coordination Centre (SSCC) that shares the same campus with B.USOC. Local cooperation between the two centres, together with other space payloads such as TARANIS and ground-based networks will greatly optimize ASIM payload operations as well as scientific return. Neubert, T., and the ASIM Team, ASIM - an Instrument Suite for the International Space Station, Corte Workshop 2008, Coupling of Thunderstorms and Lightning Discharges to Near-Earth, Corsica, 2008, edited by N. B. Crosby et al, American Institute of Physics, 978-0-7354-0657-5/09/, 2009.
Diffuse near-infrared reflectance spectroscopy during heatstroke in a mouse model: pilot study.
Abookasis, David; Zafrir, Elad; Nesher, Elimelech; Pinhasov, Albert; Sternklar, Shmuel; Mathews, Marlon S
2012-10-01
Heatstroke, a form of hyperthermia, is a life-threatening condition characterized by an elevated core body temperature that rises above 40°C (104°F) and central nervous system dysfunction that results in delirium, convulsions, or coma. Without emergency treatment, the victim lapses into a coma and death soon follows. The study presented was conducted with a diffuse reflectance spectroscopy (DRS) setup to assess the effects of brain dysfunction that occurred during heatstroke in mice model (n=6). It was hypothesized that DRS can be utilized in small animal studies to monitor change in internal brain tissue temperature during heatstroke injury since it induces a sequence of pathologic changes that change the tissue composition and structure. Heatstroke was induced by exposure of the mice body under general anesthesia, to a high ambient temperature. A type of DRS in which the brain tissue was illuminated through the intact scalp with a broadband light source and diffuse reflected spectra was employed, taking in the spectral region between 650 and 1000 nm and acquired at an angle of 90 deg at a position on the scalp ∼12 mm from the illumination site. The temperature at the onset of the experiment was ∼34°C (rectal temperature) with increasing intervals of 1°C until mouse death. The increase in temperature caused optical scattering signal changes consistent with a structural alteration of brain tissue, ultimately resulting in death. We have found that the peak absorbance intensity and its second derivative at specific wavelengths correlate well with temperature with an exponential dependence. Based on these findings, in order to estimate the influence of temperature on the internal brain tissue a reflectance-temperature index was established and was seen to correlate as well with measured temperature. Overall, results indicate variations in neural tissue properties during heatstroke and the feasibility to monitor and assess internal temperature variations using DRS. Although several approaches have described the rise in temperature and its impact on tissue, to the best of our knowledge no information is available describing the ability to monitor temperature during heatstroke with DRS. The motivation of this study was to successfully describe this ability.
Prairie Monitoring Protocol Development: North Coast and Cascades Network
McCoy, Allen; Dalby, Craig
2009-01-01
The purpose of the project was to conduct research that will guide development of a standard approach to monitoring several components of prairies within the North Coast and Cascades Network (NCCN) parks. Prairies are an important element of the natural environment at many parks, including San Juan Island National Historical Park (NHP) and Ebey's Landing National Historical Reserve (NHR). Forests have been encroaching on these prairies for many years, and so monitoring of the prairies is an important resource issue. This project specifically focused on San Juan Island NHP. Prairies at Ebey's Landing NHR will be monitored in the future, but that park was not mapped as part of this prototype project. In the interest of efficiency, the Network decided to investigate two main issues before launching a full protocol development effort: (1) the imagery requirements for monitoring prairie components, and (2) the effectiveness of software to assist in extracting features from the imagery. Several components of prairie monitoring were initially identified as being easily tracked using aerial imagery. These components included prairie/forest edge, broad prairie composition (for example, shrubs, scattered trees), and internal exclusions (for example, shrubs, bare ground). In addition, we believed that it might be possible to distinguish different grasses in the prairies if the imagery were of high enough resolution. Although the areas in question at San Juan Island NHP are small enough that mapping on the ground with GPS (Global Positioning System) would be feasible, other applications could benefit from aerial image acquisition on a regular, recurring basis and thereby make the investment in aerial imagery worthwhile. The additional expense of orthorectifying the imagery also was determined to be cost-effective.
Microbiological monitoring of marine recreational waters in southern California.
Schiff, K C; Weisberg, S B; Dorsey, J H
2001-01-01
An inventory was conducted to assess the number, type, spatial distribution, and costs of microbiological monitoring programs in southern California marine waters from Point Conception to the US/Mexico International Border. The location of each sampling site was determined using global positioning system (GPS), and estimates of geographic coverage were determined using geographic information system (GIS) techniques. Twenty-one programs conducted 87,007 tests annually at 576 sites in the study area. The largest number of sites was sampled in Orange County, whereas the largest number of analyses was performed in Los Angeles County because monitoring programs in this area focused on daily monitoring. Fifteen of the 21 programs were managed by National Pollutant Discharge Elimination System (NPDES) permitted sewage effluent dischargers who sampled both offshore and shoreline waters and typically tested for three indicator bacteria (total coliform, fecal coliform, and enterococcus). Their combined efforts comprised 82% of all of the microbiological indicator analyses conducted on an annual basis. Five of the remaining monitoring organizations were public health agencies, which typically focus their efforts on testing only total coliforms. Laboratory methodology also varied considerably, with NPDES permittees predominantly utilizing membrane filtration while public health agencies generally used multiple tube fermentation or premanufactured test kits. Nearly three quarters of all the effort expended in southern California occurred along the shoreline as opposed to offshore locations. Two thirds of this shoreline effort was focused on high-use sandy beaches and in proximity to perennial fresh-water outlets (storm drains and creeks). Most sampling occurred at a set of fixed sites that were revisited frequently, but only represented about 7% of the total shoreline. We estimated that roughly $3 million is spent annually on monitoring bathing water quality in southern California, exceeding that spent in any other part of the country.
A Ten-year Assessment of Anabolic Steroid Misuse among Competitive Athletes in Puerto Rico
Acevedo, P; Jorge, JC; Cruz-Sánchez, A; Amy, E; Barreto-Estrada, JL
2012-01-01
Objective Little is known about anabolic androgenic steroids (AAS) misuse in the Caribbean region in spite of increased popularity among athletes and adolescents. The present study examines the usage of AAS among competitive athletes in Puerto Rico. Methods Doping test results of competitive athletes obtained by random sampling out of competition during the 2000–2009 period were analysed. Doping tests were executed by the Centre for Sports, Health and Exercise Sciences (Albergue Olímpico, Salinas, Puerto Rico). A total of 550 athletes were monitored during 2000–2009. Information was collected with regard to competitive sport, gender and AAS compounds whenever a positive test result was encountered. Results From the total sample of monitored cases during the past decade, 5.4% showed adverse analytical findings. Anabolic androgenic steroids misuse was detected among male (62%) and female (38%) athletes. Weightlifting showed the greatest percentage of positive AAS doping test results (70% of total cases) and stanozolol was the most commonly misused exogenous androgen (60% of abused AAS whether alone or as part of a cocktail). Testosterone was the most common endogenous misused steroid (10% of misused compounds). Conclusion In Puerto Rico, AAS misuse was detected across competitive sports for both genders. Although AAS misuse among Puerto Rican athletes shares some features that are consistent with the international sports community, it is imperative to address AAS misuse in the Caribbean region. PMID:22519228
A review on bridge dynamic displacement monitoring using global positioning system and accelerometer
NASA Astrophysics Data System (ADS)
Yunus, Mohd Zulkifli Mohd; Ibrahim, Nuremira; Ahmad, Fatimah Shafinaz
2018-02-01
This paper reviews previous research on bridge dynamic displacement monitoring using Global Positioning System (GPS) and an accelerometer for Structural Health Monitoring (SHM) of bridge. These include the review of the advantages and disadvantages of the measurement as well as the methodology of the measurements used in the recent research study. This review could provide a preliminary decision overview for students or researchers before initiating a research related to the bridge dynamic displacement monitoring.
When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors.
O'Connell, Sandra; ÓLaighin, Gearóid; Quinlan, Leo R
2017-01-01
Physical activity is an essential aspect of a healthy lifestyle for both physical and mental health states. As step count is one of the most utilized measures for quantifying physical activity it is important that activity-monitoring devices be both sensitive and specific in recording actual steps taken and disregard non-stepping body movements. The objective of this study was to assess the specificity of five activity monitors during a variety of prescribed non-stepping activities. Participants wore five activity monitors simultaneously for a variety of prescribed activities including deskwork, taking an elevator, taking a bus journey, automobile driving, washing and drying dishes; functional reaching task; indoor cycling; outdoor cycling; and indoor rowing. Each task was carried out for either a specific duration of time or over a specific distance. Activity monitors tested were the ActivPAL micro™, NL-2000™ pedometer, Withings Smart Activity Monitor Tracker (Pulse O2)™, Fitbit One™ and Jawbone UP™. Participants were video-recorded while carrying out the prescribed activities and the false positive step count registered on each activity monitor was obtained and compared to the video. All activity monitors registered a significant number of false positive steps per minute during one or more of the prescribed activities. The Withings™ activity performed best, registering a significant number of false positive steps per minute during the outdoor cycling activity only (P = 0.025). The Jawbone™ registered a significant number of false positive steps during the functional reaching task and while washing and drying dishes, which involved arm and hand movement (P < 0.01 for both). The ActivPAL™ registered a significant number of false positive steps during the cycling exercises (P < 0.001 for both). As a number of false positive steps were registered on the activity monitors during the non-stepping activities, the authors conclude that non-stepping physical activities can result in the false detection of steps. This can negatively affect the quantification of physical activity with regard to step count as an output. The Withings™ activity monitor performed best with regard to specificity during the activities of daily living tested.
Quigley, Martin M; Mate, Timothy P; Sylvester, John E
2009-01-01
To evaluate the accuracy, utility, and cost effectiveness of a new electromagnetic patient positioning and continuous, real-time monitoring system, which uses permanently implanted resonant transponders in the target (Calypso 4D Localization System and Beacon transponders, Seattle, WA) to continuously monitor tumor location and movement during external beam radiation therapy of the prostate. This clinical trial studied 43 patients at 5 sites. All patients were implanted with 3 transponders each. In 41 patients, the system was used for initial alignment at each therapy session. Thirty-five patients had continuous monitoring during their radiation treatment. Over 1,000 alignment comparisons were made to a commercially available kV X-ray positioning system (BrainLAB ExacTrac, Munich, Germany). Using decision analysis and Markov processes, the outcomes of patients were simulated over a 5-year period and measured in terms of costs from a payer's perspective and quality-adjusted life years (QALYs). All patients had satisfactory transponder implantations for monitoring purposes. In over 75% of the treatment sessions, the correction to conventional positioning (laser and tattoos) directed by an electromagnetic patient positioning and monitoring system was greater than 5 mm. Ninety-seven percent (34/35) of the patients who underwent continuous monitoring had target motion that exceeded preset limits at some point during the course of their radiation therapy. Exceeding preset thresholds resulted in user intervention at least once during the therapy in 80% of the patients (28/35). Compared with localization using ultrasound, electronic portal imaging devices (EPID), or computed tomography (CT), localization with the electromagnetic patient positioning and monitoring system yielded superior gains in QALYs at comparable costs. Most patients positioned with conventional tattoos and lasers for prostate radiation therapy were found by use of the electromagnetic patient positioning and monitoring system to have alignment errors exceeding 5 mm. Almost all patients undergoing external beam radiation of the prostate have been shown to have target organ movement exceeding 3 mm during radiation therapy delivery. The ability of the electromagnetic technology to monitor tumor target location during the same time as radiation therapy is being delivered allows clinicians to provide real time adaptive radiation therapy for prostate cancer. This permits clinicians to intervene when the prostate moves outside the radiation isocenter, which should decrease adverse events and improve patient outcomes. Additionally, a cost-utility analysis has demonstrated that the electromagnetic patient positioning and monitoring system offers patient outcome benefits at a cost that falls well within the payer's customary willingness to pay (WTP) threshold of $50,000 per QALY.
Positive Aspects of International Student Transitions: A Qualitative Inquiry
ERIC Educational Resources Information Center
Moores, Lisa; Popadiuk, Natalee
2011-01-01
Despite the considerable growth of the international student population, positive aspects of their experience have received little attention. The current study combines a Critical Incident Technique methodology and a positive psychology lens to explore the cross-cultural transition of seven international students, focusing on facilitative factors,…
High Resolution BPM Upgrade for the ATF Damping Ring at KEK
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eddy, N.; Briegel, C.; Fellenz, B.
2011-08-17
A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital down-conversion techniques, digital signal processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented. The next generation of linear colliders require ultra-low vertical emittance of <2 pm-rad. The damping ring at the KEK Accelerator Test Facilitymore » (ATF) is designed to demonstrate this mission critical goal. A high resolution beam position monitor (BPM) system for the damping ring is one of the key tools for realizing this goal. The BPM system needs to provide two distnict measurements. First, a very high resolution ({approx}100-200nm) closed-orbit measurement which is averaged over many turns and realized with narrowband filter techniques - 'narrowband mode'. This is needed to monitor and steer the beam along an optimum orbit and to facilitate beam-based alignment to minimize non-linear field effects. Second, is the ability to make turn by turn (TBT) measurements to support optics studies and corrections necessary to achieve the design performance. As the TBT measurement necessitates a wider bandwidth, it is often referred to as 'wideband mode'. The BPM upgrade was initiated as a KEK/SLAC/FNAL collaboration in the frame of the Global Design Initiative of the International Linear Collider. The project was realized and completed using Japan-US funds with Fermilab as the core partner.« less
Internal dosimetry technical basis manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-12-20
The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophicalmore » discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.« less
NASA Astrophysics Data System (ADS)
Becker-Reshef, I.; Justice, C. O.
2012-12-01
Earth observation data, owing to their synoptic, timely and repetitive coverage, have long been recognized as an indispensible tool for agricultural monitoring at local to global scales. Research and development over the past several decades in the field of agricultural remote sensing has led to considerable capacity for crop monitoring within the current operational monitoring systems. These systems are relied upon nationally and internationally to provide crop outlooks and production forecasts as the growing season progresses. This talk will discuss the legacy and current state of operational agricultural monitoring using earth observations. In the US, the National Aeronautics and Space Administration (NASA) and the US Department of Agriculture (USDA) have been collaborating to monitor global agriculture from space since the 1970s. In 1974, the USDA, NASA and National Oceanic and Atmospheric Administration (NOAA) initiated the Large Area Crop Inventory Experiment (LACIE) which demonstrated that earth observations could provide vital information on crop production, with unprecedented accuracy and timeliness, prior to harvest. This experiment spurred many agencies and researchers around the world to further develop and evaluate remote sensing technologies for timely, large area, crop monitoring. The USDA and NASA continue to closely collaborate. More recently they jointly initiated the Global Agricultural Monitoring Project (GLAM) to enhance the agricultural monitoring and the crop-production estimation capabilities of the USDA Foreign Agricultural Service by using the new generation of NASA satellite observations including from MODIS and the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments. Internationally, in response to the growing calls for improved agricultural information, the Group on Earth Observations (partnership of governments and international organizations) developed the Global Agricultural Monitoring (GEOGLAM) initiative which was adopted by the G20 as part of the action plan on food price volatility and agriculture. The goal of GEOGLAM is to enhance agricultural production estimates through leveraging advances in the research domain and in satellite technologies, and integrating these into the existing operational monitoring systems.
Bergallo, M; Costa, C; Tarallo, S; Daniele, R; Merlino, C; Segoloni, G P; Negro Ponzi, A; Cavallo, R
2006-06-01
The human cytomegalovirus (HCMV) is an important pathogen in immunocompromised patients, such as transplant recipients. The use of sensitive and rapid diagnostic assays can have a great impact on antiviral prophylaxis and therapy monitoring and diagnosing active disease. Quantification of HCMV DNA may additionally have prognostic value and guide routine management. The aim of this study was to develop a reliable internally-controlled quantitative-competitive PCR (QC-PCR) for the detection and quantification of HCMV DNA viral load in peripheral blood and compare it with other methods: the HCMV pp65 antigenaemia assay in leukocyte fraction, the HCMV viraemia, both routinely employed in our laboratory, and the nucleic acid sequence-based amplification (NASBA) for detection of HCMV pp67-mRNA. Quantitative-competitive PCR is a procedure for nucleic acid quantification based on co-amplification of competitive templates, the target DNA and a competitor functioning as internal standard. In particular, a standard curve is generated by amplifying 10(2) to 10(5) copies of target pCMV-435 plasmid with 10(4) copies of competitor pCMV-C plasmid. Clinical samples derived from 40 kidney transplant patients were tested by spiking 10(4) copies of pCMV-C into the PCR mix as internal control, and comparing results with the standard curve. Of the 40 patients studied, 39 (97.5%) were positive for HCMV DNA by QC-PCR. While the correlation between the number of pp65-positive cells and the number of HCMV DNA genome copies/mL and the former and the pp67mRNA-positivity were statistically significant, there was no significant correlation between HCMV DNA viral load assayed by QC-PCR and HCMV viraemia. The QC-PCR assay could detect from 10(2) to over 10(7) copies of HCMV DNA with a range of linearity between 10(2) and 10(5) genomes.
Sesli, Faik Ahmet; Karsli, Fevzi; Colkesen, Ismail; Akyol, Nihat
2009-06-01
Coastline mapping and coastline change detection are critical issues for safe navigation, coastal resource management, coastal environmental protection, and sustainable coastal development and planning. Changes in the shape of coastline may fundamentally affect the environment of the coastal zone. This may be caused by natural processes and/or human activities. Over the past 30 years, the coastal sites in Turkey have been under an intensive restraint associated with a population press due to the internal and external touristic demand. In addition, urbanization on the filled up areas, settlements, and the highways constructed to overcome the traffic problems and the other applications in the coastal region clearly confirm an intensive restraint. Aerial photos with medium spatial resolution and high resolution satellite imagery are ideal data sources for mapping coastal land use and monitoring their changes for a large area. This study introduces an efficient method to monitor coastline and coastal land use changes using time series aerial photos (1973 and 2002) and satellite imagery (2005) covering the same geographical area. Results show the effectiveness of the use of digital photogrammetry and remote sensing data on monitoring large area of coastal land use status. This study also showed that over 161 ha areas were filled up in the research area and along the coastal land 12.2 ha of coastal erosion is determined for the period of 1973 to 2005. Consequently, monitoring of coastal land use is thus necessary for coastal area planning in order to protecting the coastal areas from climate changes and other coastal processes.
Ambient lighting: setting international standards for the viewing of softcopy chest images
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Ryan, John; Evanoff, Micheal G.; Keeling, Aoife; Chakraborty, Dev; Manning, David; Brennan, Patrick C.
2007-03-01
Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and <10 Lux. All monitors were calibrated to DICOM part 14 GSDF. Sixty radiologists were presented with 30 chest images, 15 images having simulated nodular lesions of varying subtlety and size. Lesions were positioned in accordance with typical clinical presentation and were validated radiologically. Each image was presented for 30 seconds and viewers were asked to identify and score any visualized lesion from 1-4 to indicate confidence level of detection. At the end of the session, sensitivity and specificity were calculated. Analysis of the data suggests that visualization of chest lesions is affected by inappropriate lighting with chest radiologists demonstrating greater ambient lighting dependency. JAFROC analyses are currently being performed.
Review article: practical current issues in perioperative patient safety.
Eichhorn, John H
2013-02-01
This brief review provides an overview and, importantly, a context perspective of relevant current practical issues in perioperative patient safety. The dramatic improvement in anesthesia patient safety over the last 30 years was not initiated by electronic monitors but, rather, largely by a set of behaviours known as "safety monitoring" that were then made decidedly more effective by extending the human senses through electronic monitoring, for example, capnography and pulse oximetry. In the highly developed world, this current success is threatened by complacency and production pressure. In some areas of the developing/underdeveloped world, the challenge is implementing the components of anesthesia practice that will bring safety improvements to parallel the overall current success, for instance, applying the World Federation of Societies of Anaesthesiologists (WFSA) "International Standards for A Safe Practice of Anaesthesia". Generally, expanding the current success in safety involves many practical issues. System issues involve research, effective reporting mechanisms and analysis/broadcasting of results, perioperative communication (including "speaking up to power"), and checklists. Monitoring issues involve enforcing existing published monitoring standards and also recognizing the risk of danger to the patient from hypoventilation during procedural sedation and from postoperative intravenous pain medications. Issues of clinical care include medication errors in the operating room, cerebral hypoperfusion (especially in the head-up position), dangers of airway management, postoperative residual weakness from muscle relaxants, operating room fires, and risks specific in obstetric anesthesia. Recognition of the issues outlined here and empowerment of all anesthesia professionals, from the most senior professors and administrators to the newest practitioners, should help maintain, solidify, and expand the improvements in anesthesia and perioperative patient safety.
PPP Sliding Window Algorithm and Its Application in Deformation Monitoring.
Song, Weiwei; Zhang, Rui; Yao, Yibin; Liu, Yanyan; Hu, Yuming
2016-05-31
Compared with the double-difference relative positioning method, the precise point positioning (PPP) algorithm can avoid the selection of a static reference station and directly measure the three-dimensional position changes at the observation site and exhibit superiority in a variety of deformation monitoring applications. However, because of the influence of various observing errors, the accuracy of PPP is generally at the cm-dm level, which cannot meet the requirements needed for high precision deformation monitoring. For most of the monitoring applications, the observation stations maintain stationary, which can be provided as a priori constraint information. In this paper, a new PPP algorithm based on a sliding window was proposed to improve the positioning accuracy. Firstly, data from IGS tracking station was processed using both traditional and new PPP algorithm; the results showed that the new algorithm can effectively improve positioning accuracy, especially for the elevation direction. Then, an earthquake simulation platform was used to simulate an earthquake event; the results illustrated that the new algorithm can effectively detect the vibrations change of a reference station during an earthquake. At last, the observed Wenchuan earthquake experimental results showed that the new algorithm was feasible to monitor the real earthquakes and provide early-warning alerts.
ERIC Educational Resources Information Center
Tarc, Paul; Mishra Tarc, Aparna
2015-01-01
The elite international school is a rich site for sociological inquiry in global times. In this paper, we conceptualize the international school as a transnational space of agonist social class-making given the dynamic positioning of the complement of international school actors. We position international schoolteachers in the middle of these…
Allen, Lilian A
2018-02-12
The purpose of this study was to explore the experiences of internationally educated nurses in management positions in United States health care organisations to understand the obstacles and support these individuals' experience when pursuing and working in managerial roles. Although internationally educated nurses are an integral part of the US health care industry, few work in managerial roles. Little is known about the experiences of internationally educated nurses who do obtain management positions. In this qualitative, phenomenological study, seven internationally educated nurses who were managers in Chicago, Illinois, responded to open-ended interview questions. Supervisors contributed to the participants' acceptance of management positions. The participants experienced challenges such as cultural differences, language, and communication. Despite these challenges, the participants had positive working relationships with staff and supervisors. Further, the participants had opportunities for education and professional growth. Internationally educated nurses benefit from participating in organisational committees. They face challenges related to work responsibilities, cultural differences and communication but can succeed in management roles through developing strategies to overcome the challenges and through receiving support from staff, colleagues and supervisors. More internationally educated nurses may obtain managerial positions if supervisors provide encouragement and support. © 2018 John Wiley & Sons Ltd.
Global positioning system (GPS) civil monitoring performance specification.
DOT National Transportation Integrated Search
2009-04-30
This Civil Monitoring Performance Specification (CMPS) is published and maintained at : the direction of the Program Manager for Civil Applications, Global Positioning Systems : Wing (GPSW). The purpose of this document is to provide a comprehensive ...
Patel, Bella; Rai, Lena; Buck, Georgina; Richards, Sue M; Mortuza, Yeasmin; Mitchell, Wayne; Gerrard, Gareth; Moorman, Anthony V; Duke, Veronique; Hoffbrand, A Victor; Fielding, Adele K; Goldstone, Anthony H; Foroni, Letizia
2010-01-01
The predictive value of molecular minimal residual disease (MRD) monitoring using polymerase chain reaction amplification of clone-specific immunoglobulin or T-cell Receptor rearrangements was analysed in 161 patients with non T-lineage Philadelphia-negative acute lymphoblastic leukaemia (ALL) participating in the UK arm of the international ALL trial UKALL XII/Eastern Cooperative Oncology Group (ECOG) 2993. MRD positivity (> or =10(-4)) in patients treated with chemotherapy alone was associated with significantly shorter relapse-free survival (RFS) at several time-points during the first year of therapy. MRD status best discriminated outcome after phase 2 induction, when the relative risk of relapse was 8.95 (2.85-28.09)-fold higher in MRD-positive (> or =10(-4)) patients and the 5-year RFS 15% [95% confidence interval (CI) 0-40%] compared to 71% (56-85%) in MRD-negative (<10(-4)) patients (P = 0.0002) When MRD was detected prior to autologous stem cell transplantation (SCT), a significantly higher rate of treatment failure was observed [5-year RFS 25% (CI 0-55%) vs. 77% (95% CI 54-100%) in MRD-negative/<10(-4), P = 0.01] whereas in recipients of allogeneic-SCT in first complete remission, MRD positivity pre-transplant did not adversely affect outcome. These data provide a rationale for introducing MRD-based risk stratification in future studies for the delineation of those at significant risk of treatment failure in whom intensification of therapy should be evaluated.
Employing moderate resolution sensors in human rights and international humanitarian law monitoring
NASA Astrophysics Data System (ADS)
Marx, Andrew J.
Organizations concerned with human rights are increasingly using remote sensing as a tool to improve their detection of human rights and international humanitarian law violations. However, as these organizations have transitioned to human rights monitoring campaigns conducted over large regions and extended periods of time, current methods of using fine- resolution sensors and manpower-intensive analyses have become cost- prohibitive. To support the continued growth of remote sensing in human rights and international humanitarian law monitoring campaigns, this study researches how moderate resolution land observatories can provide complementary data to operational human rights monitoring efforts. This study demonstrates the capacity of moderate resolutions to provide data to monitoring efforts by developing an approach that uses Landsat Enhanced Thematic Mapper Plus (ETM+) as part of a system for the detection of village destruction in Darfur, Sudan. Village destruction is an indicator of a human rights or international humanitarian law violations in Darfur during the 2004 study period. This analysis approach capitalizes on Landsat's historical archive and systematic observations by constructing a historic spectral baseline for each village in the study area that supports automated detection of a potentially destroyed village with each new overpass of the sensor. Using Landsat's near-infrared band, the approach demonstrates high levels of accuracy when compared with a U.S. government database documenting destroyed villages. This approach is then applied to the Darfur conflict from 2002 to 2008, providing new data on when and where villages were destroyed in this widespread and long-lasting conflict. This application to the duration of a real-world conflict illustrates the abilities and shortcomings of moderate resolution sensors in human rights monitoring efforts. This study demonstrates that moderate resolution satellites have the capacity to contribute complementary data to operational human rights monitoring efforts. While this study validates this capacity for the burning of villages in arid environments, this approach can be generalized to detect other human rights violations if an observable signal that represents the violation is identified.
Microbial monitoring of spacecraft and associated environments
NASA Technical Reports Server (NTRS)
La Duc, M. T.; Kern, R.; Venkateswaran, K.
2004-01-01
Rapid microbial monitoring technologies are invaluable in assessing contamination of spacecraft and associated environments. Universal and widespread elements of microbial structure and chemistry are logical targets for assessing microbial burden. Several biomarkers such as ATP, LPS, and DNA (ribosomal or spore-specific), were targeted to quantify either total bioburden or specific types of microbial contamination. The findings of these assays were compared with conventional, culture-dependent methods. This review evaluates the applicability and efficacy of some of these methods in monitoring the microbial burden of spacecraft and associated environments. Samples were collected from the surfaces of spacecraft, from surfaces of assembly facilities, and from drinking water reservoirs aboard the International Space Station (ISS). Culture-dependent techniques found species of Bacillus to be dominant on these surfaces. In contrast, rapid, culture-independent techniques revealed the presence of many Gram-positive and Gram-negative microorganisms, as well as actinomycetes and fungi. These included both cultivable and noncultivable microbes, findings further confirmed by DNA-based microbial detection techniques. Although the ISS drinking water was devoid of cultivable microbes, molecular-based techniques retrieved DNA sequences of numerous opportunistic pathogens. Each of the methods tested in this study has its advantages, and by coupling two or more of these techniques even more reliable information as to microbial burden is rapidly obtained. Copyright 2004 Springer-Verlag.
Bailey, Timothy S.; Klaff, Leslie J.; Wallace, Jane F.; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A.
2016-01-01
Background: As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Methods: Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects’ self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. Results: In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (−0.64% to −2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. Conclusions: These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. PMID:26902794
The Effectiveness of Contrasting Protected Areas in Preventing Deforestation in Madre de Dios, Peru
NASA Astrophysics Data System (ADS)
Vuohelainen, Anni Johanna; Coad, Lauren; Marthews, Toby R.; Malhi, Yadvinder; Killeen, Timothy J.
2012-10-01
Accurate monitoring of the effectiveness of protected areas (PAs) in decreasing deforestation is increasingly important given the vital role of forest protection in climate change mitigation. Recent studies on PA effectiveness have used remote-sensing imagery to compare deforestation rates within PAs to surrounding areas. However, remote-sensing data used in isolation provides limited information on the factors contributing to effectiveness. We used landscape-modelling techniques to estimate the effectiveness of ten PAs in Madre de Dios, Peru. Factors influencing PA effectiveness were investigated using in situ key-informant interviews. Although all of the PAs studied had positive effectiveness scores, those with the highest scores were ecotourism and conservation concessions, where monitoring and surveillance activities and good relations with surrounding communities were reported as possible factors in decreasing deforestation rates. Native community areas had the lowest scores, with deforestation mainly driven by internal resource use and population growth. Weak local governance and immigration were identified as underlying factors decreasing the effectiveness of protection, whereas good relations with surrounding communities and monitoring activity increased effectiveness. The results highlight the need to combine remote sensing with in situ information on PA management because identification of drivers and deterrents of deforestation is vital for improving the effectiveness of protection.
The effectiveness of contrasting protected areas in preventing deforestation in Madre de Dios, Peru.
Vuohelainen, Anni Johanna; Coad, Lauren; Marthews, Toby R; Malhi, Yadvinder; Killeen, Timothy J
2012-10-01
Accurate monitoring of the effectiveness of protected areas (PAs) in decreasing deforestation is increasingly important given the vital role of forest protection in climate change mitigation. Recent studies on PA effectiveness have used remote-sensing imagery to compare deforestation rates within PAs to surrounding areas. However, remote-sensing data used in isolation provides limited information on the factors contributing to effectiveness. We used landscape-modelling techniques to estimate the effectiveness of ten PAs in Madre de Dios, Peru. Factors influencing PA effectiveness were investigated using in situ key-informant interviews. Although all of the PAs studied had positive effectiveness scores, those with the highest scores were ecotourism and conservation concessions, where monitoring and surveillance activities and good relations with surrounding communities were reported as possible factors in decreasing deforestation rates. Native community areas had the lowest scores, with deforestation mainly driven by internal resource use and population growth. Weak local governance and immigration were identified as underlying factors decreasing the effectiveness of protection, whereas good relations with surrounding communities and monitoring activity increased effectiveness. The results highlight the need to combine remote sensing with in situ information on PA management because identification of drivers and deterrents of deforestation is vital for improving the effectiveness of protection.
Speckle-correlation monitoring of the internal micro-vascular flow
NASA Astrophysics Data System (ADS)
Zimnyakov, D. A.; Khmara, M. B.; Vilensky, M. A.; Kozlov, V. V.; Gorfinkel, I. V.; Zdrajevsky, R. A.
2009-10-01
The results of experimental study of possibility to monitor the micro-vascular blood flow in superficial tissues of various organs with the use of endoscope-based full-field speckle correlometer are presented. The blood microcirculation monitoring was carried out in the course of the laparotomy of abdominal cavity of laboratory animals (rats). Transfer of laser light to the area of interest and scattered radiation from the probed zone to the detector (CMOS camera) was carried out via fiber-optic bundles of endoscopic system. Microscopic hemodynamics was analyzed for small intestine, liver, spleen, kidney, and pancreas under different conditions (normal state, provocated peritonitis and ischemia, administration of vasodilative agents such as papaverine, lidocaine). The prospects and problems of internal monitoring of microvascular flow in laboratory and clinical conditions are discussed.
Hanford internal dosimetry program manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.
1989-10-01
This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs.
NASA Technical Reports Server (NTRS)
Hilbert, Kent; Anderson, Daniel; Lewis, David
2007-01-01
Data collected via the International GPM Program could be used to provide a solution for the NOAA Estuarine Reserves Division s System-wide Monitoring Program by augmenting in situ rainfall measurements with data acquired via future satellite-acquired precipitation data. This Candidate Solution is in alignment with the Coastal Management National Application and will benefit society by assisting in estuary preservation.
WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats Monitor
NASA Astrophysics Data System (ADS)
Mckay, Myles
2017-08-01
The UVIS detector has a population of pixels that exhibit anomalous QE variations between anneals, characterized by a sensitivity loss that is greater in the shorter wavelengths(blue) than in the longer wavelengths(red). This population is distributed randomly, with evidence of grouping behavior in the UV, and is seemingly different for each anneal cycle. This program, a continuation of cycle 24 program 14546, will aim to constrain the maximum low-sensitivity population existing before an anneal in both the UV and Visible filters. To monitor the UV behavior, internal flats with the Deuterium D2 lamp will be taken through the filters, F225W and F336W. To monitor the behavior in the Visible filters, internal flats with the tungsten lamp will be taken through F814W and F438W a week before the anneal, when the population of anomalous pixels is the greatest.
Space-based radar for the United Nations's international satellite monitoring agency
NASA Astrophysics Data System (ADS)
Cantafio, L. J.
1984-12-01
A session of the United Nations General Assembly was held in May and June 1978 with the objective to discuss questions related to disarmament. It was decided to consider the establishment of an international Satellite Monitoring Agency (ISMA). The arising questions were studied, and two reports were prepared concerning such a monitoring agency. One report contained preliminary conclusions on the technical, legal, and financial implications of establishing an ISMA, while the second report contained an in-depth study. It was found that from a technical point of view the project appeared possible and feasible, and that there were no provisions in the international law prohibiting the proposed activities. The present investigation has been conducted under the assumption that an ISMA will be estabished. Attention is given to the requirements for the ISMA, the space-based radar design, radar system tradeoff data, critical technologies, and system weight, cost and schedule.
Cunningham, Daniel J; Shearer, David A; Carter, Neil; Drawer, Scott; Pollard, Ben; Bennett, Mark; Eager, Robin; Cook, Christian J; Farrell, John; Russell, Mark; Kilduff, Liam P
2018-01-01
The assessment of competitive movement demands in team sports has traditionally relied upon global positioning system (GPS) analyses presented as fixed-time epochs (e.g., 5-40 min). More recently, presenting game data as a rolling average has become prevalent due to concerns over a loss of sampling resolution associated with the windowing of data over fixed periods. Accordingly, this study compared rolling average (ROLL) and fixed-time (FIXED) epochs for quantifying the peak movement demands of international rugby union match-play as a function of playing position. Elite players from three different squads (n = 119) were monitored using 10 Hz GPS during 36 matches played in the 2014-2017 seasons. Players categorised broadly as forwards and backs, and then by positional sub-group (FR: front row, SR: second row, BR: back row, HB: half back, MF: midfield, B3: back three) were monitored during match-play for peak values of high-speed running (>5 m·s-1; HSR) and relative distance covered (m·min-1) over 60-300 s using two types of sample-epoch (ROLL, FIXED). Irrespective of the method used, as the epoch length increased, values for the intensity of running actions decreased (e.g., For the backs using the ROLL method, distance covered decreased from 177.4 ± 20.6 m·min-1 in the 60 s epoch to 107.5 ± 13.3 m·min-1 for the 300 s epoch). For the team as a whole, and irrespective of position, estimates of fixed effects indicated significant between-method differences across all time-points for both relative distance covered and HSR. Movement demands were underestimated consistently by FIXED versus ROLL with differences being most pronounced using 60 s epochs (95% CI HSR: -6.05 to -4.70 m·min-1, 95% CI distance: -18.45 to -16.43 m·min-1). For all HSR time epochs except one, all backs groups increased more (p < 0.01) from FIXED to ROLL than the forward groups. Linear mixed modelling of ROLL data highlighted that for HSR (except 60 s epoch), SR was the only group not significantly different to FR. For relative distance covered all other position groups were greater than the FR (p < 0.05). The FIXED method underestimated both relative distance (~11%) and HSR values (up to ~20%) compared to the ROLL method. These differences were exaggerated for the HSR variable in the backs position who covered the greatest HSR distance; highlighting important consideration for those implementing the FIXED method of analysis. The data provides coaches with a worst-case scenario reference on the running demands required for periods of 60-300 s in length. This information offers novel insight into game demands and can be used to inform the design of training games to increase specificity of preparation for the most demanding phases of matches.
How maternal malnutrition affects linear growth and development in the offspring.
Papathakis, Peggy C; Singh, Lauren N; Manary, Mark J
2016-11-05
Maternal malnutrition is common in the developing world and has detrimental effects on both the mother and infant. Pre-pregnancy nutritional status and weight gain during pregnancy are positively related to fetal growth and development. Internationally, there is no agreement on the method of diagnosis or treatment of moderate or severe malnutrition during pregnancy. Establishing clear guidelines for diagnosis and treatment will be essential in elevating the problem. Possible anthropometric measurements used to detect and monitor maternal malnutrition include pre-pregnancy BMI, weight gain, and mid upper arm circumference. Food supplements have the potential to increase gestational weight gain and energy intake which are positively associated with fetal growth and development. Overall more studies are needed to conclude the impact of food/nutrient supplements on infant growth in undernourished pregnant women in developing countries. Currently, a study underway may provide much needed documentation of the benefits of treating malnutrition in pregnancy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Differential dynamic microscopy of bidisperse colloidal suspensions.
Safari, Mohammad S; Poling-Skutvik, Ryan; Vekilov, Peter G; Conrad, Jacinta C
2017-01-01
Research tasks in microgravity include monitoring the dynamics of constituents of varying size and mobility in processes such as aggregation, phase separation, or self-assembly. We use differential dynamic microscopy, a method readily implemented with equipment available on the International Space Station, to simultaneously resolve the dynamics of particles of radius 50 nm and 1 μm in bidisperse aqueous suspensions. Whereas traditional dynamic light scattering fails to detect a signal from the larger particles at low concentrations, differential dynamic microscopy exhibits enhanced sensitivity in these conditions by accessing smaller wavevectors where scattering from the large particles is stronger. Interference patterns due to scattering from the large particles induce non-monotonic decay of the amplitude of the dynamic correlation function with the wavevector. We show that the position of the resulting minimum contains information on the vertical position of the particles. Together with the simple instrumental requirements, the enhanced sensitivity of differential dynamic microscopy makes it an appealing alternative to dynamic light scattering to characterize samples with complex dynamics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cruz J.; Patterson, J.; Pepper, S.
2012-07-15
The U.S. Support Program (USSP) to International Atomic Energy Agency (IAEA) Safeguards established a program of one-year paid internships for students and recent graduates. The program was in effect from 2002 until 2006 with a total of forty-one U.S. citizens and permanent residents placed in the IAEA. The USSP created a Junior Professional Officer (JPO) Program in 2005 that replaced the internship program at the IAEA. The JPO program creates opportunities for U.S. college graduates to become IAEA employees for a period of one to two years to help increase the effectiveness and efficiency of safeguards. The twenty three formermore » and current JPOs work in varying fields such as software development, information collection and analysis, non-destructive analysis systems, and unattended monitoring systems. This paper will look at the impacts of the USSP internship and JPO program on the interns and JPOs, the U.S. government, and the IAEA. Academic backgrounds, past involvement in nuclear fields, program assessment, and post-program positions were recorded and analyzed through two studies using questionnaires sent to former interns and former and current JPOs. This paper will discuss the effects of the programs on the careers of the interns and JPOs, present the evaluations of the internship and JPO Programs, and report the recommendations for changes.« less
Globalization of public health law and ethics.
Sohn, Myongsei
2012-09-01
The Constitution of the World Health Organization (1946) states that the "enjoyment of the highest attainable standard of health is one of the fundamental rights of every human being without distinction of race, religion, political belief, economic or social position." The international legal framework for this right was laid by the Universal Declaration of Human Rights (1948) and reaffirmed in the International Covenant on Economic, Social, and Cultural Rights (1966) and the Declaration of Alma-Ata (1978). In recent years, the framework has been developed on 10 key elements: national and international human rights, laws, norms, and standards; resource constraints and progressive realization; obligations of immediate effect; freedoms and entitlements; available, accessible, acceptable, and good quality; respect, protect, and fulfill; non-discrimination, equality, and vulnerability; active and informed participation; international assistance and cooperation; and monitoring and accountability. Whereas public health law plays an essential role in the protection and promotion of the right to health, the emergence of SARS (2003) highlighted the urgent need to reform national public health laws and international obligations relating to public health in order to meet the new realities of a globalized world, leading to the WHO Framework Convention on Tobacco Control (2003) and the revision of the WHO International Health Regulations (2005). The Asian Institute for Bioethics and Health Law, in conjunction with the Republic of Korea's Ministry of Health and Welfare and the WHO International Digest of Health Legislation, conducted a comparative legal analysis of national public health laws in various countries through a project entitled Domestic Profiles of Public/Population Health Legislation (2006), which underscored the importance of recognizing the political and social contexts of distinct legal cultures, including Western, Asian, Islamic, and African.
Taylor, K D; Raymond, H Fisher; Truong, H-H M; Ick, T; Le, B; Rive, J; McFarland, W
2011-10-01
We measured the prevalence of international travel, the demographic and risk profile of international travellers and risk and preventive behaviours of travellers among HIV-negative and HIV-positive men who have sex with men (MSM), based in San Francisco, CA, USA, through the addition of questions to the local implementation of the National HIV Behavioral Surveillance survey in 2008. Of 270 MSM participating in the survey, slightly more than one-quarter (26.3%) had travelled internationally in the last year. Those with a history of international travel were more likely to be foreign born, of a higher socioeconomic status and HIV uninfected. Of eight HIV-positive MSM who travelled internationally (11.3% of HIV-positive MSM), all were on antiretroviral therapy and only three recalled being vaccinated for hepatitis A and B. Human papillomavirus infection was also higher among international travellers. Travel health services must be improved to address special needs of this population of international travellers.
Code of Federal Regulations, 2014 CFR
2014-04-01
.... (a) Spot-month limits. (1) For all Referenced Contracts executed pursuant to their rules, swap..., establish rules and procedures for monitoring and enforcing spot-month position limits set at levels no... monitoring and enforcing spot-month position limits set at levels no greater than 25 percent of estimated...
The First International Biosphere Reserve Congress.
ERIC Educational Resources Information Center
Laird, John
1984-01-01
Presents objectives (and related activities) of a plan designed for international collaboration in conserving key natural areas (biosphere reserves) of the globe. The plan (focusing on such areas as management, conservation, research, monitoring, and environmental education/training) was formulated during the First International Biosphere Reserve…
NASA Technical Reports Server (NTRS)
Fishman, Julianna L.; Mudgett, Paul D.; Packham, Nigel J.; Schultz, John R.; Straub, John E., II
2005-01-01
On August 9, 2003, NASA, with the cooperative support of the Vehicle Office of the International Space Station Program, the Advanced Human Support Technology Program, and the Johnson Space Center Habitability and Environmental Factors Office released a Request for Information, or RFI, to identify next-generation environmental monitoring systems that have demonstrated ability or the potential to meet defined requirements for monitoring air and water quality onboard the International Space Station. This report summarizes the review and analysis of the proposed solutions submitted to meet the water quality monitoring requirements. Proposals were to improve upon the functionality of the existing Space Station Total Organic Carbon Analyzer (TOCA) and monitor additional contaminants in water samples. The TOCA is responsible for in-flight measurement of total organic carbon, total inorganic carbon, total carbon, pH, and conductivity in the Space Station potable water supplies. The current TOCA requires hazardous reagents to accomplish the carbon analyses. NASA is using the request for information process to investigate new technologies that may improve upon existing capabilities, as well as reduce or eliminate the need for hazardous reagents. Ideally, a replacement for the TOCA would be deployed in conjunction with the delivery of the Node 3 water recovery system currently scheduled for November 2007.
A study of interferences in ozone UV and chemiluminescence monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudgens, E.E.; Kleindienst, T.E.; McElroy, F.F.
A study was conducted to examine interferences and other measurement anomalies in chemiluminescence and ultraviolet ozone monitors. Previous results had show that there was a positive deviation in the chemiluminescence monitors and no direct interference with ultraviolet monitors due to the presence of water at non-condensing concentrations. The present study continues this effort, examining both potential positive and negative effects of moisture and other interferences on these monitors. Aromatic compounds and their oxidation products could potentially show a positive interference with ultraviolet monitors, and test measurements were made with aromatics such as toluene, benzaldehyde, and nitrotoluene to determine their possiblemore » retention in the ozone scrubber and their absorption in the cell as a function of the humidity. A detailed examination of the scrubbers used in ultraviolet ozone monitors has also been undertaken. Ozone scrubbers that have shown anomalous behavior in the field have been studied in various reduced-efficacy modes under controlled laboratory conditions. Longer term tests of unused scrubbers for possible ozone breakthrough under exposure to various simulated field conditions were initiated.« less
Soil quality monitoring: Examples of existing protocols
Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese
2010-01-01
Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference,or in support of...
Soil quality monitoring: examples of existing protocols
Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese
2010-01-01
Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference, or in support of...
Temperate non-breeding surveys - a key to shorebird conservation
Sue Thomas
2005-01-01
Completion of the United States and Canadian shorebird conservation plans recently identified and prioritized shorebird monitoring, management, and conservation needs in the Western Hemisphere. We present an emerging approach to monitor shorebird use of temperate non-breeding areas under the Program for Regional and International Shorebird Monitoring (PRISM). This...
Development and Progression of a Model: Prospective Research Compliance Monitoring
ERIC Educational Resources Information Center
Fedor, Carol; Ferrazzano Yaussy, Cristina; Cola, Philip A.
2008-01-01
Recent trends in Human Research Protection Programs (HRPPs) have contributed to the rising emphasis on prospective monitoring of clinical research and education programs. Therefore, internal efforts and resources to monitor investigator compliance and site performance have become an important focus in the conduct of clinical research. Once the…
Genetic monitoring as a promising tool for conservation and management
Michael K. Schwartz; Gordon Luikart; Robin S. Waples
2007-01-01
In response to ever-increasing anthropogenic changes to natural ecosystems, regional, national and international organizations have established guidelines for monitoring biological diversity. Most monitoring programs, however, do not take full advantage of the potential afforded by molecular genetic markers, which can provide information relevant to both ecological and...
Hansen, Andreas Wolff; Dahl-Petersen, Inger; Helge, Jørn Wulff; Brage, Søren; Grønbæk, Morten; Flensborg-Madsen, Trine
2014-03-01
The International Physical Activity Questionnaire (IPAQ) is commonly used in surveys, but reliability and validity has not been established in the Danish population. Among participants in the Danish Health Examination survey 2007-2008, 142 healthy participants (45% men) wore a unit that combined accelerometry and heart rate monitoring (Acc+HR) for 7 consecutive days and then completed the IPAQ. Background data were obtained from the survey. Physical activity energy expenditure (PAEE) and time in moderate, vigorous, and sedentary intensity levels were derived from the IPAQ and compared with estimates from Acc+HR using Spearman's correlation coefficients and Bland-Altman plots. Repeatability of the IPAQ was also assessed. PAEE from the 2 methods was significantly positively correlated (0.29 and 0.49; P = 0.02 and P < 0.001; for women and men, respectively). Men significantly overestimated PAEE by IPAQ (56.2 vs 45.3 kJ/kg/day, IPAQ: Acc+HR, P < .01), while the difference was nonsignificant for women (40.8 vs 44.4 kJ/kg/day). Bland-Altman plots showed that the IPAQ overestimated PAEE, moderate, and vigorous activity without systematic error. Reliability of the IPAQ was moderate to high for all domains and intensities (total PAEE intraclass correlation coefficient = 0.58). This Danish Internet-based version of the long IPAQ had modest validity and reliability when assessing PAEE at population level.
Lab-on-a-Chip: From Astrobiology to the International Space Station
NASA Technical Reports Server (NTRS)
Maule, Jake; Wainwright, Nor; Steele, Andrew; Gunter, Dan; Monaco, Lisa A.; Wells, Mark E.; Morris, Heather C.; Boudreaux, Mark E.
2008-01-01
The continual and long-term habitation of enclosed environments, such as Antarctic stations, nuclear submarines and space stations, raises unique engineering, medical and operational challenges. There is no easy way out and no easy way to get supplies in. This situation elevates the importance of monitoring technology that can rapidly detect events within the habitat that affect crew safety such as fire, release of toxic chemicals and hazardous microorganisms. Traditional methods to monitor microorganisms on the International Space Station (ISS) have consisted of culturing samples for 3-5 days and eventual sample return to Earth. To augment these culture methods with new, rapid molecular techniques, we developed the Lab-on-a-Chip Application Development - Portable Test System (LOCAD-PTS). The system consists of a hand-held spectrophotometer, a series of interchangeable cartridges and a surface sampling/dilution kit that enables crew to collect samples and detect a range of biological molecules, all within 15 minutes. LOCAD-PTS was launched to the ISS aboard Space Shuttle Discovery in December 2006, where it was operated for the first time during March-May 2007. The surfaces of five separate sites in the US Lab and Node 1 of ISS were analyzed for endotoxin, using cartridges that employ the Limulus Amebocyte Lysate (LAL) assay; results of these tests will be presented. LOCAD-PTS will remain permanently onboard ISS with new cartridges scheduled for launch in February and October of 2008 for the detection of fungi (Beta-glucan) and Gram-positive bacteria (lipoteichoic acid), respectively.
Regional ionospheric TEC data assimilation and now-casting service
NASA Astrophysics Data System (ADS)
Aa, E.; Liu, S.; Wengeng, H.
2017-12-01
Ionospheric data assimilation is a now-casting technique to incorporate irregular ionospheric measurements into certain background model, which is an effective and efficient way to overcome the limitation of the unbalanced data distribution and to improve the accuracy of the model, so that the model and the data can be optimally combined with each other to produce a more reliable and reasonable system specification. In this study, a regional total electron content (TEC) now-casting system over China and adjacent areas (70E-140E and 15N-55N) is developed on the basis of data assimilation technique. The International Reference Ionosphere (IRI) is used here as background model, and the GNSS data are derived from both the Space Environment Monitoring Network of Chinese Academy of Sciences (SEMnet) and International GNSS Service (IGS) data. A Three-dimensional variation algorithm (3DVAR) combined with Gauss-Markov Kalman filter technique is used to implement the data assimilation. The regional gridded TEC maps and the position errors of single-frequency GPS receivers can be generated and publicized online (http://sepc.ac.cn/TEC_chn.php) in quasi-real time, which is updated for every 15 min. It is one of the ionospheric now-casting systems in China based on data assimilation algorithm, which can be used not only for real-time monitoring of ionosphere environment over China and adjacent areas, but also in providing accurate and effective specification of regional ionospheric TEC and error correction for satellite navigation, radar imaging, shortwave communication, and other relevant applications.
Moncrieff, J
1994-03-18
A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.
Rabinowitz, Jill A.; Drabick, Deborah A.G.; Reynolds, Maureen D.; Clark, Duncan B.; Olino, Thomas M.
2016-01-01
Temperamental flexibility and lower positive parenting are associated with internalizing and externalizing problems; however, youth varying in flexibility may be differentially affected by positive parenting in the prediction of symptoms. We examined whether children's flexibility moderated prospective relations between maternal and paternal positive parenting and youth internalizing and externalizing symptoms during adolescence. Participants (N =775, 71% male) and their caregivers completed measures when youth were 10-12 and 12-14 years old. Father positive parenting interacted with child flexibility to predict father-reported internalizing and externalizing problems. Consistent with the diathesis-stress model, children lower in flexibility experienced greater symptoms than children higher in flexibility in lower positive parenting contexts. Among children lower in flexibility, lower paternal positive parenting was associated with greater internalizing and externalizing symptoms compared to higher paternal positive parenting. However, among youth higher in flexibility, symptom levels were similar regardless of whether youth experienced lower or higher paternal positive parenting. PMID:26834305
Hip rotation range of motion in sitting and prone positions in healthy Japanese adults
Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi
2015-01-01
[Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186
Time-lapse monitoring of TLR2 ligand internalization with newly developed fluorescent probes.
Arai, Yohei; Yokoyama, Kouhei; Kawahara, Yuki; Feng, Qi; Ohta, Ippei; Shimoyama, Atsushi; Inuki, Shinsuke; Fukase, Koichi; Kabayama, Kazuya; Fujimoto, Yukari
2018-05-23
As a mammalian toll-like receptor family member protein, TLR2 recognizes lipoproteins from bacteria and modulates the immune response by inducing the expression of various cytokines. We have developed fluorescence-labeled TLR2 ligands with either hydrophilic or hydrophobic fluorescence groups. The labeled ligands maintained the inflammatory IL-6 induction activity and enabled us to observe the internalization and colocalization of the TLR2 ligands using live-cell imaging. The time-lapse monitoring in the live-cell imaging of the fluorescence-labeled TLR2 ligand showed that TLR2/CD14 expression in the host cells enhanced the internalization of TLR2 ligand molecules.
Clinical Monitoring of Smooth Surface Enamel Lesions Using CP-OCT During Nonsurgical Intervention
Chan, Kenneth H.; Tom, Henry; Lee, Robert C.; Kang, Hobin; Simon, Jacob C.; Staninec, Michal; Darling, Cynthia L.; Pelzner, Roger B.; Fried, Daniel
2017-01-01
Introduction Studies have shown that cross-polarization optical coherence tomography (CP-OCT) can be used to image the internal structure of carious lesions in vivo. The objective of this study was to show that CP-OCT can be used to monitor changes in the internal structure of early active carious lesions on smooth surfaces during non-surgical intervention with fluoride. Methods Lesions on the smooth surfaces of teeth were imaged using CP-OCT on 17 test subjects. Lesion structural changes were monitored during fluoride varnish application at 6-week intervals for 30 weeks. The lesion depth (Ld), integrated reflectivity (ΔR), and surface zone thickness (Sz) were monitored. Results A distinct transparent surface zone that may be indicative of lesion arrestment was visible in CP-OCT images on 62/63 lesions before application of fluoride varnish. The lesion depth and internal structure were resolved for all the lesions. The overall change in the mean values for Ld, ΔR, and Sz for all the lesions was minimal and was not significant during the study (P > 0.05). Only 5/63 lesions manifested a significant increase in Sz during intervention. Conclusion Even though it appears that most of the lesions manifested little change with fluoride varnish application in the 30 weeks of the study, CP-OCT was able to measure the depth and internal structure of all the lesions including the thickness of the important transparent surface zone located at the surface of the lesions, indicating that CP-OCT is ideally suited for monitoring lesion severity in vivo. PMID:26955902
Movement Demands of Elite Under-20s and Senior International Rugby Union Players
Drawer, Scott; Pollard, Ben; Eager, Robin; Taylor, Neil; Cook, Christian J.
2016-01-01
This study compared the movement demands of elite international Under-20 age grade (U20s) and senior international rugby union players during competitive tournament match play. Forty elite professional players from an U20 and 27 elite professional senior players from international performance squads were monitored using 10Hz global positioning systems (GPS) during 15 (U20s) and 8 (senior) international tournament matches during the 2014 and 2015 seasons. Data on distances, velocities, accelerations, decelerations, high metabolic load (HML) distance and efforts, and number of sprints were derived. Data files from players who played over 60 min (n = 258) were separated firstly into Forwards and Backs, and more specifically into six positional groups; FR–Front Row (prop & hooker), SR–Second Row, BR–Back Row (Flankers & No.8), HB–Half Backs (scrum half & outside half), MF–Midfield (centres), B3 –Back Three (wings & full back) for match analysis. Linear mixed models revealed significant differences between U20 and senior teams in both the forwards and backs. In the forwards the seniors covered greater HML distance (736.4 ± 280.3 vs 701.3 ± 198.7m, p = 0.01) and severe decelerations (2.38 ± 2.2 vs 2.28 ± 1.65, p = 0.05) compared to the U20s, but performed less relative HSR (3.1 ± 1.6 vs 3.2 ± 1.5, p < 0.01), moderate (19.4 ± 10.5 vs 23.6 ± 10.5, p = 0.01) and high accelerations (2.2 ± 1.9 vs 4.3 ± 2.7, p < 0.01) and sprint•min-1 (0.11 ± 0.06 vs 0.11 ± 0.05, p < 0.01). Senior backs covered a greater relative distance (73.3 ± 8.1 vs 69.1 ± 7.6 m•min-1, p < 0.01), greater High Metabolic Load (HML) distance (1138.0 ± 233.5 vs 1060.4 ± 218.1m, p < 0.01), HML efforts (112.7 ± 22.2 vs 98.8 ± 21.7, p < 0.01) and heavy decelerations (9.9 ± 4.3 vs 9.5 ± 4.4, p = 0.04) than the U20s backs. However, the U20s backs performed more relative HSR (7.3 ± 2.1 vs 7.2 ± 2.1, p <0.01) and sprint•min-1 (0.26 ± 0.07 vs 0.25 ± 0.07, p < 0.01). Further investigation highlighted differences between the 6 positional groups of the teams. The positional groups that differed the most on the variables measured were the FR and MF groups, with the U20s FR having higher outputs on HSR, moderate & high accelerations, moderate, high & severe decelerations, HML distance, HML efforts, and sprints•min-1. For the MF group the senior players produced greater values for relative distance covered, HSR, moderate decelerations, HML distance and sprint•min-1. The BR position group was most similar with the only differences seen on heavy accelerations (U20s higher) and moderate decelerations (seniors higher). Findings demonstrate that U20s internationals appear to be an adequate ‘stepping stone’ for preparing players for movement characteristics found senior International rugby, however, the current study highlight for the first time that certain positional groups may require more time to be able to match the movement demands required at a higher playing level than others. Conditioning staff must also bear in mind that the U20s players whilst maintaining or improving match movement capabilities may require to gain substantial mass in some positions to match their senior counterparts. PMID:27824865
Movement Demands of Elite Under-20s and Senior International Rugby Union Players.
Cunningham, Daniel J; Shearer, David A; Drawer, Scott; Pollard, Ben; Eager, Robin; Taylor, Neil; Cook, Christian J; Kilduff, Liam P
2016-01-01
This study compared the movement demands of elite international Under-20 age grade (U20s) and senior international rugby union players during competitive tournament match play. Forty elite professional players from an U20 and 27 elite professional senior players from international performance squads were monitored using 10Hz global positioning systems (GPS) during 15 (U20s) and 8 (senior) international tournament matches during the 2014 and 2015 seasons. Data on distances, velocities, accelerations, decelerations, high metabolic load (HML) distance and efforts, and number of sprints were derived. Data files from players who played over 60 min (n = 258) were separated firstly into Forwards and Backs, and more specifically into six positional groups; FR-Front Row (prop & hooker), SR-Second Row, BR-Back Row (Flankers & No.8), HB-Half Backs (scrum half & outside half), MF-Midfield (centres), B3 -Back Three (wings & full back) for match analysis. Linear mixed models revealed significant differences between U20 and senior teams in both the forwards and backs. In the forwards the seniors covered greater HML distance (736.4 ± 280.3 vs 701.3 ± 198.7m, p = 0.01) and severe decelerations (2.38 ± 2.2 vs 2.28 ± 1.65, p = 0.05) compared to the U20s, but performed less relative HSR (3.1 ± 1.6 vs 3.2 ± 1.5, p < 0.01), moderate (19.4 ± 10.5 vs 23.6 ± 10.5, p = 0.01) and high accelerations (2.2 ± 1.9 vs 4.3 ± 2.7, p < 0.01) and sprint•min-1 (0.11 ± 0.06 vs 0.11 ± 0.05, p < 0.01). Senior backs covered a greater relative distance (73.3 ± 8.1 vs 69.1 ± 7.6 m•min-1, p < 0.01), greater High Metabolic Load (HML) distance (1138.0 ± 233.5 vs 1060.4 ± 218.1m, p < 0.01), HML efforts (112.7 ± 22.2 vs 98.8 ± 21.7, p < 0.01) and heavy decelerations (9.9 ± 4.3 vs 9.5 ± 4.4, p = 0.04) than the U20s backs. However, the U20s backs performed more relative HSR (7.3 ± 2.1 vs 7.2 ± 2.1, p <0.01) and sprint•min-1 (0.26 ± 0.07 vs 0.25 ± 0.07, p < 0.01). Further investigation highlighted differences between the 6 positional groups of the teams. The positional groups that differed the most on the variables measured were the FR and MF groups, with the U20s FR having higher outputs on HSR, moderate & high accelerations, moderate, high & severe decelerations, HML distance, HML efforts, and sprints•min-1. For the MF group the senior players produced greater values for relative distance covered, HSR, moderate decelerations, HML distance and sprint•min-1. The BR position group was most similar with the only differences seen on heavy accelerations (U20s higher) and moderate decelerations (seniors higher). Findings demonstrate that U20s internationals appear to be an adequate 'stepping stone' for preparing players for movement characteristics found senior International rugby, however, the current study highlight for the first time that certain positional groups may require more time to be able to match the movement demands required at a higher playing level than others. Conditioning staff must also bear in mind that the U20s players whilst maintaining or improving match movement capabilities may require to gain substantial mass in some positions to match their senior counterparts.
Fanchini, Maurizio; Impellizzeri, Franco M; Silbernagel, Karin Grävare; Combi, Franco; Benazzo, Franco; Bizzini, Mario
2018-01-01
To describe the Return to competition after Achilles Tendon rupture (ATR) in an elite soccer player. Case report. Return to sport (RTS) of a professional soccer player who suffered an ATR during a match. The RTS phase started 15 weeks after surgery and specific on-field activities were gradually introduced. Criteria used to monitor the transition through the different phases were strength and endurance of the calf muscle and ability to sustain specific on-field training loads (TL) monitored with Global Positioning System and heart-rate system. TLs were weekly compared to pre-injury values to evaluate recovery and to prescribe future sessions. A 39-year-old (height 178 cm, weight 75 kg) elite soccer defender player, playing in Italian Serie-A league. Days of absence were lower compared to a cohort presented in UEFA study (119 versus 161 ± 65 days, respectively). External-TL and Internal-TL were organized to gradually increase during RTS and resulted in higher values prior to return to competition compared to pre-injury values. Concentric plantar flexion peak torque increased till 9th months after surgery. Monitoring of the field activities allowed comparison with pre-injury values and provided a useful and functional criteria to pass return to team activity and competition. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kalra, Amit; Roessner, Cameron; Jupp, Jennifer; Williamson, Tyler; Tellier, Raymond; Chaudhry, Ahsan; Khan, Faisal; Taparia, Minakshi; Jimenez-Zepeda, Victor H; Stewart, Douglas A; Daly, Andrew; Storek, Jan
2018-05-01
Post-transplant lymphoproliferative disorder (PTLD) is a potentially fatal complication of allogeneic hematopoietic cell transplantation (HCT). Epstein-Barr virus (EBV) reactivation (detectable DNAemia) predisposes to the development of PTLD. We retrospectively studied 306 patients monitored for EBV DNAemia after Thymoglobulin-conditioned HCT to determine the utility of the monitoring in the management of PTLD. DNAemia was monitored weekly for ≥12 weeks post-transplantation. Reactivation was detected in 82% of patients. PTLD occurred in 14% of the total patients (17% of patients with reactivation). PTLD was treated with rituximab only when and if the diagnosis was established. This allowed us to evaluate potential DNAemia thresholds for pre-emptive therapy. We suggest 100,000-500,000 IU per mL whole blood as this would result in unnecessary rituximab administration to only 4-20% of patients and near zero mortality due to PTLD. After starting rituximab (for diagnosed PTLD), sustained regression of PTLD occurred in 25/25 (100%) patients in whom DNAemia became undetectable. PTLD progressed or relapsed in 12/17 (71%) patients in whom DNAemia was persistently detectable. In conclusion, for pre-emptive therapy of PTLD, we suggest threshold DNAemia of 100,000-500,000 IU/mL. Persistently detectable DNAemia after PTLD treatment with rituximab appears to have 71% positive predictive value and 100% negative predictive value for PTLD progression/relapse. Copyright © 2018 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Stephenson, S. R.; Babiker, M.; Sandven, S.; Muckenhuber, S.; Korosov, A.; Bobylev, L.; Vesman, A.; Mushta, A.; Demchev, D.; Volkov, V.; Smirnov, K.; Hamre, T.
2015-12-01
Sea ice monitoring and forecasting systems are important tools for minimizing accident risk and environmental impacts of Arctic maritime operations. Satellite data such as synthetic aperture radar (SAR), combined with atmosphere-ice-ocean forecasting models, navigation models and automatic identification system (AIS) transponder data from ships are essential components of such systems. Here we present first results from the SONARC project (project term: 2015-2017), an international multidisciplinary effort to develop novel and complementary ice monitoring and forecasting systems for vessels and offshore platforms in the Arctic. Automated classification methods (Zakhvatkina et al., 2012) are applied to Sentinel-1 dual-polarization SAR images from the Barents and Kara Sea region to identify ice types (e.g. multi-year ice, level first-year ice, deformed first-year ice, new/young ice, open water) and ridges. Short-term (1-3 days) ice drift forecasts are computed from SAR images using feature tracking and pattern tracking methods (Berg & Eriksson, 2014). Ice classification and drift forecast products are combined with ship positions based on AIS data from a selected period of 3-4 weeks to determine optimal vessel speed and routing in ice. Results illustrate the potential of high-resolution SAR data for near-real-time monitoring and forecasting of Arctic ice conditions. Over the next 3 years, SONARC findings will contribute new knowledge about sea ice in the Arctic while promoting safe and cost-effective shipping, domain awareness, resource management, and environmental protection.
NASA Astrophysics Data System (ADS)
Zemke, Kornelia; Liebscher, Axel; Möller, Fabian
2017-04-01
One of the key requirements for safe CO2 storage operation is to ensure wellbore integrity. The CO2 triggered acid in-well environment may lead to pitting and/or surface corrosion and eventually to fatigue of well casings and cementation by this giving raise to wellbore leakage. Corrosion effects are conventionally monitored by measurement of inner casing surface, internal diameter and wall thickness. Caliper logging provides inner surface and internal diameter data while ultrasonic tools measure both the internal diameter and casing thickness as well as the bonding between casing and cement. However, both tools can only monitor and characterize the most inner casing and ultrasonic tools in addition can only be applied in fluid filled wells. At the Ketzin CO2 storage test site, Germany, about 67 kt of CO2 were injected between June 2008 and August 2013 and an interdisciplinary monitoring concept was developed with focus on the storage complex, the overburden, the surface and the wellbores. Four deep wells penetrate the reservoir and their integrity has been monitored by a combination of video inspection, pulsed neutron gamma logging PNG and magnetic imaging defectoscopy MID. MID is an advanced logging method for non-destructive testing and has the great advantages that it can be operated in gas filled boreholes and that it provides information also for outer casings. The MID tool generates electromagnetic pulsed transient eddy currents and records the response of the surrounding media. The distribution and strength of the eddy-currents is then converted into averaged, depth-resolved thicknesses of the individual casings. Run in time-lapse mode, MID provides a measure to detect changes in casing thickness and therefore hints to corrosion. At Ketzin, the four deep wells haven been monitored by repeat MID logging on a roughly annual basis in cooperation with VNG Gasspeicher GmbH (VGS) and GAZPROMENERGODIAGNOSTIKA, applying their in-house MID tool. The MID based depth-resolved casing thickness data clearly image the thickness of at least the two innermost casings and the depth positions of the pipe-connectors and of all downhole installations in perfect agreement with depth data from the drilling reports. Also the transition from steel casing to glass fiber reinforced casing in well Ktzi 203 is well resolved. The MID derived casing thicknesses are within the production specifications and also confirm to the API standards. Comparison between the different time-lapse data sets provides no hints to time dependent changes in casing thickness or to any other signs of corrosion. These results agree with the video inspection of the wells and the investigation of in-situ samples of pulled casing material recovered during abandoned of well Ktzi 202. The Ketzin time-lapse MID data set provides unique field experience on applicability of MID monitoring and longevity of wellbore steel casing under real CO2 storage environment. It thereby substantially improves our knowledge on CCS safety assessment due to the key role of well integrity during the entire storage lifecycle.
Do prospective workday appraisals influence end-of-workday affect and self-monitored performance?
Grawitch, Matthew J; Granda, Stephanie E; Barber, Larissa K
2008-10-01
The current study uses self-regulation as the basis for a model that examines the influence of three types of workday appraisals (resource, task, and response). At the beginning of their workday, a total of 170 faculty, graduate students, and staff of a university completed appraisal ratings of their anticipated workday tasks, resources, and responses. At the end of the workday, they completed assessments of positive and negative affect and self-monitored performance. Results suggested that resource appraisals of control and skills were predictive of task appraisals of difficulty, threat, and ambiguity. Task appraisals were then predictive of both response appraisals, in terms of anticipated support and effort, and self-monitored performance at the end of the day. Anticipated effort and self-monitored performance were both positively related to positive affect at the end of the day. Anticipated support and self-monitored performance were both negatively related to negative affect at the end of the day, while threat task appraisals were positively related to negative affect. Implications of the results for workplace interventions are discussed.
Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T
2001-09-01
Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.
2011-04-25
CAPE CANAVERAL, Fla. - In the Vehicle Assembly Building (VAB) at NASA's Kennedy Space Center in Florida, workers monitor the progress of external fuel tank, ET-138, for space shuttle Atlantis' STS-135 mission, as it is positioned between the twin solid rocket boosters on the mobile launcher platform in high bay-1. Shuttle Atlantis' move, or "rollover," from Orbiter Processing Facility-1 to the VAB is targeted for May 10. Once there it will be mated with the external tank and boosters. Atlantis and its crew of four will deliver the Raffaello multipurpose logistics module packed with supplies and spare parts to the International Space Station. STS-135 is targeted to launch June 28, and will be the last spaceflight for the Space Shuttle Program. Photo credit: NASA/Jack Pfaller
Strong RFI observed in protected 21 cm band at Zurich observatory, Switzerland
NASA Astrophysics Data System (ADS)
Monstein, C.
2014-03-01
While testing a new antenna control software tool, the telescope was moved to the most western azimuth position pointing to our own building. While de-accelerating the telescope, the spectrometer showed strong broadband radio frequency interference (RFI) and two single-frequency carriers around 1412 and 1425 MHz, both of which are in the internationally protected band. After lengthy analysis it was found out, that the Webcam AXIS2000 was the source for both the broadband and single-frequency interference. Switching off the Webcam solved the problem immediately. So, for future observations of 21 cm radiation, all nearby electronics has to be switched off. Not only the Webcam but also all unused PCs, printers, networks, monitors etc.
Luyckx, Koen; Tildesley, Elizabeth A; Soenens, Bart; Andrews, Judy A; Hampson, Sarah E; Peterson, Missy; Duriez, Bart
2011-01-01
This study investigated how parenting accounted for interindividual differences in developmental trajectories of different child behaviors across childhood and adolescence. In a cohort sequential community sample of 1,049 children, latent class growth analysis was applied to three parent-reported dimensions (monitoring, positive parenting, inconsistent discipline) across 12 annual assessments (ages 6-18). Four longitudinal parenting styles (authoritative, authoritarian, indulgent, uninvolved) were differentiated on the basis of levels and rates of change in the constituent parenting dimensions. Multigroup analyses demonstrated that these parenting styles were differentially related to changes in parent- and child-reported measures of children's alcohol and cigarette use, antisocial behavior, and internalizing symptoms, with the authoritative parenting class being related to the most optimal long-term development.
Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jianchao; Ding, Yonghua, E-mail: yhding@mail.hust.edu.cn; Zhang, Xiaoqing
2014-11-15
A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma coremore » and boundary.« less
Cavity BPM system tests for the ILC energy spectrometer
NASA Astrophysics Data System (ADS)
Slater, M.; Adolphsen, C.; Arnold, R.; Boogert, S.; Boorman, G.; Gournaris, F.; Hildreth, M.; Hlaing, C.; Jackson, F.; Khainovski, O.; Kolomensky, Yu. G.; Lyapin, A.; Maiheu, B.; McCormick, D.; Miller, D. J.; Orimoto, T. J.; Szalata, Z.; Thomson, M.; Ward, D.; Wing, M.; Woods, M.
2008-07-01
The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10-4 or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 h for a 1 m long BPM triplet. We find micron-level stability over 1 h for 3 BPM stations distributed over a 30 m long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.
NASA Astrophysics Data System (ADS)
Sun, Dong; Meng, Xiangjun; Ren, Tianming; Fawcett, John Paul; Wang, Hualu; Gu, Jingkai
2018-04-01
Sensitivity is generally an issue in bioassays of prostaglandins and their synthetic analogs due to their extremely low concentration in vivo. To improve the ionization efficiency of limaprost, an oral prostaglandin E1 (PGE1) synthetic analog, we investigated a charge reversal derivatization strategy in electrospray ionization mass spectrometry (ESI-MS). We established that the cholamine derivative exhibits much greater signal intensity in the positive-ion mode compared with limaprost in the negative ion mode. Collision-induced dissociation (CID) involved exclusive neutral mass loss and positive charge migration to form stable cationic product ions with the positive charge on the limaprost residue rather than on the modifying group. This has the effect of maintaining the efficiency and specificity of multiple reaction monitoring (MRM) and avoiding cross talk. CID fragmentation patterns of other limaprost derivatives allowed us to relate the dissociation tendency of different neutral leaving groups to an internal energy distribution scale based on the survival yield method. Knowledge of the energy involved in the production of stabilized positive ions will potentially assist the selection of suitable derivatization reagents for the analysis of a wide variety of lipid acids. [Figure not available: see fulltext.
Effects of four different positive airway pressures on right internal jugular vein catheterisation.
Zhou, Qinghe; Xiao, Wangpin; An, Erdan; Zhou, Hongmei; Yan, Min
2012-05-01
The right internal jugular vein (RIJV) is often used for central venous catheterisation in patients undergoing major surgery. The efficacy of this route correlates with the diameter of the vein which can be influenced by airway pressure. To investigate four positive airway pressures (PAPs) in mechanically ventilated patients and to determine the most suitable of these for RIJV catheterisation. Prospective, randomised, controlled study. Two Chinese medical centres. Two hundred and forty patients scheduled for gastrointestinal tract surgery under general anaesthesia (male-to-female ratio, 135 : 105; American Society of Anesthesiologists' physical status class, I-III; age range, 19-81 years); patients were excluded from the study if they had a history of haematological disease, external neck injury, RIJV catheterisation, severe cardiovascular disease, RIJV thrombosis, injection-site infection, pneumothorax and pulmonary bulla. They were randomised into four groups of 60, each to undergo RIJV catheterisation at a PAP of 0 (1 cmH2O = 0.098 kPa, group A); 15 (group B); 20 (group C); and 25 cmH2O (group D). Primary outcomes were central venous pressure (CVP) and RIJV cross-sectional area which were measured before and during PAP; the number of catheterisations completed in 30 s; the number of first pass punctures; heart rate and mean arterial pressure which were monitored continuously; and the incidence of complications which included local haematoma, pneumothorax and internal carotid artery (ICA) puncture. Two patients were excluded following ICA puncture, leaving 238 for analysis. In groups C and D, the CVP and the cross-sectional area of RIJV were significantly larger; the number completing catheterisation within 30 s and the number of first pass punctures increased significantly and was comparable between these two groups. Compared with groups A and B, the incidences of hypotension and bradycardia were significantly increased in groups C and D. The incidence of local haematoma was significantly increased in group D compared with other groups. RIJV catheterisation was completed successfully in all but two patients in group A. A PAP of 20 cmH2O seems most suitable for successful RIJV catheterisation in mechanically ventilated patients. It is associated with an increase in cross-sectional RIJV area and CVP, which facilitate cannulation, and results in fewer puncture-related complications. However, meticulous haemodynamic monitoring is needed to avoid hypotension and bradycardia.
NASA Astrophysics Data System (ADS)
Wang, Jin; Xu, Fan; Lu, GuoDong
2017-09-01
More complex problems of simultaneous position and internal force control occur with cooperative manipulator systems than that of a single one. In the presence of unwanted parametric and modelling uncertainties as well as external disturbances, a decentralised position synchronised force control scheme is proposed. With a feedforward neural network estimating engine, a precise model of the system dynamics is not required. Unlike conventional cooperative or synchronised controllers, virtual position and virtual synchronisation errors are introduced for internal force tracking control and task space position synchronisation. Meanwhile joint space synchronisation and force measurement are unnecessary. Together with simulation studies and analysis, the position and the internal force errors are shown to asymptotically converge to zero. Moreover, the controller exhibits different characteristics with selected synchronisation factors. Under certain settings, it can deal with temporary cooperation by an intelligent retreat mechanism, where less internal force would occur and rigid collision can be avoided. Using a Lyapunov stability approach, the controller is proven to be robust in face of the aforementioned uncertainties.
Acoustic measurements of soil-pipeflow and internal erosion
USDA-ARS?s Scientific Manuscript database
Internal erosion of soil pipes can lead to embankment failures, landslides, and gully erosion. Therefore, non-intrusive methods are needed to detect and monitor soil pipeflow and the resulting internal erosion. This paper presents a laboratory study using both active and passive acoustic techniques ...
Acoustic measurements of soil pipeflow and internal erosion
USDA-ARS?s Scientific Manuscript database
Internal erosion of soil pipes can lead to embankment failures, landslides, and gully erosion therefore non-intrusive methods are needed to detect and monitor soil pipeflow and the resulting internal erosion. This paper presents a laboratory study using both active and passive acoustic techniques to...
Skripochka and Kaleri watch monitor
2011-03-04
ISS026-E-031766 (4 March 2011) --- Russian cosmonauts Oleg Skripochka (foreground) and Alexander Kaleri, both Expedition 26 flight engineers, watch a computer monitor in the Zvezda Service Module of the International Space Station.
Du, Guofeng; Li, Zhao; Song, Gangbing
2018-05-23
Impact loads can have major adverse effects on the safety of civil engineering structures, such as concrete-filled steel tubular (CFST) columns. The study of mechanical behavior and stress analysis of CFST columns under impact loads is very important to ensure their safety against such loads. At present, the internal stress monitoring of the concrete cores CFST columns under impact loads is still a very challenging subject. In this paper, a PVDF (Polyvinylidene Fluoride) piezoelectric smart sensor was developed and successfully applied to the monitoring of the internal stress of the concrete core of a CFST column under impact loads. The smart sensor consists of a PVDF piezoelectric film sandwiched between two thin steel plates through epoxy. The protection not only prevents the PVDF film from impact damages but also ensures insulation and waterproofing. The smart sensors were embedded into the circular concrete-filled steel tube specimen during concrete pouring. The specimen was tested against impact loads, and testing data were collected. The time history of the stress obtained from the PVDF smart sensor revealed the evolution of core concrete internal stress under impact loads when compared with the impact force⁻time curve of the hammer. Nonlinear finite element simulations of the impact process were also carried out. The results of FEM simulations had good agreement with the test results. The results showed that the proposed PVDF piezoelectric smart sensors can effectively monitor the internal stress of concrete-filled steel tubular columns under impact loads.
NASA Technical Reports Server (NTRS)
Oubre, Cherie; Khodadad, Christina; Castro, Victoria; Ott, Mark; Pollack, Lawrence; Roman, Monsi
2017-01-01
The RAZOR EX (Registered Trademark) PCR unit was initially developed by the DoD as part of an SBIR project to detect and identify biothreats during field deployment. The system was evaluated by NASA as a commercial technology for future microbial monitoring requirements and has been successfully demonstrated in microgravity on-board the International Space Station.
Zhu, Y Q; Long, Q; Xiao, Q F; Zhang, M; Wei, Y L; Jiang, H; Tang, B
2018-03-13
Objective: To investigate the association of blood pressure variability and sleep stability in essential hypertensive patients with sleep disorder by cardiopulmonary coupling. Methods: Performed according to strict inclusion and exclusion criteria, 88 new cases of essential hypertension who came from the international department and the cardiology department of china-japan friendship hospital were enrolled. Sleep stability and 24 h ambulatory blood pressure data were collected by the portable sleep monitor based on cardiopulmonary coupling technique and 24 h ambulatory blood pressure monitor. Analysis the correlation of blood pressure variability and sleep stability. Results: In the nighttime, systolic blood pressure standard deviation, systolic blood pressure variation coefficient, the ratio of the systolic blood pressure minimum to the maximum, diastolic blood pressure standard deviation, diastolic blood pressure variation coefficient were positively correlated with unstable sleep duration ( r =0.185, 0.24, 0.237, 0.43, 0.276, P <0.05). Conclusions: Blood pressure variability is associated with sleep stability, especially at night, the longer the unstable sleep duration, the greater the variability in night blood pressure.
Weraneck, Klaus; Heilmeier, Florian; Lindner, Markus; Graf, Moritz; Jakobi, Martin; Volk, Wolfram; Roths, Johannes; Koch, Alexander W
2016-11-04
In recent years, the observation of the behaviour of components during the production process and over their life cycle is of increasing importance. Structural health monitoring, for example of carbon composites, is state-of-the-art research. The usage of Fibre Bragg Gratings (FBGs) in this field is of major advantage. Another possible area of application is in foundries. The internal state of melts during the solidification process is of particular interest. By using embedded FBGs, temperature and stress can be monitored during the process. In this work, FBGs were embedded in aluminium alloys in order to observe the occurring strain. Two different FBG positions were chosen in the mould in order to compare its dependence. It was shown that FBGs can withstand the solidification process, although a compression in the range of one percent was measured, which is in agreement with the literature value. Furthermore, different lengths of the gratings were applied, and it was shown that shorter gratings result in more accurate measurements. The obtained results prove that FBGs are applicable as sensors for temperatures up to 740 °C.
Lee, Heon-Woo; Seo, Ji-Hyung; Choi, Seung-Ki; Lee, Kyung-Tae
2007-01-30
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5>166.1 for itopride and m/z 342.3>111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2=0.9999) over the studied range (0.5-1000 ng mL(-1)) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.
Deborah Page-Dumroese; Daniel Neary; Carl Trettin
2010-01-01
This workshop was developed to determine the state-of-the-science for soil monitoring on National Forests and Rangelands. We asked international experts in the field of soil monitoring, soil monitoring indicators, and basic forest soil properties to describe the limits of our knowledge and the ongoing studies that are providing new information. This workshop and the...
Disposable biomedical electrode
NASA Technical Reports Server (NTRS)
Frost, J. D., Jr.; Hillman, C. E., Jr.
1977-01-01
Reusable recording cap equipped with compressible snap-on bioelectronic electrodes is worn by patient to allow remote monitoring of electroencephalogram and electro-oculogram waveforms. Electrodes can be attached to inside surface of stretch-textile cap at twelve monitoring positions and at one or two ground positions.
Formaldehyde Concentration Dynamics of the International Space Station Cabin Atmosphere
NASA Technical Reports Server (NTRS)
Perry, J. L.
2005-01-01
Formaldehyde presents a significant challenge to maintaining cabin air quality on board crewed spacecraft. Generation sources include offgassing from a variety of non-metallic materials as well as human metabolism. Because generation sources are pervasive and human health can be affected by continual exposure to low concentrations, toxicology and air quality control engineering experts jointly identified formaldehyde as a key compound to be monitored as part the International Space Station's (ISS) environmental health monitoring and maintenance program. Data acquired from in-flight air quality monitoring methods are the basis for assessing the cabin environment's suitability for long-term habitation and monitoring the performance of passive and active controls that are in place to minimize crew exposure. Formaldehyde concentration trends and dynamics served in the ISS cabin atmosphere are reviewed implications to present and future flight operations discussed.
222Rn+220Rn monitoring by alpha spectrometry.
Buompane, R; Roca, V; Sabbarese, C; Pugliese, M; Quarto, M; Mattone, C
2014-07-01
Controlled 222Rn+220Rn mixed atmospheres have been realised introducing calibrated sources in a stainless steel chamber. An electrostatic alpha monitor internal to the chamber has been used for an accurate discrimination of alpha peaks due to the products of the two isotopes. In the chamber, different specific activities are achieved in order to test the response of the internal reference instrument and to evaluate the possible interferences due to contemporary presence of both radon isotopes. Results show that: (i) the atmospheres are very stable, (ii) the monitor is adequate for their control because the various alpha lines are well evaluated and (iii) using Tyvek® filter, the efficiency of monitor is stable and constant vs. activity. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
de Bortoli, N; Martinucci, I; Savarino, E; Franchi, R; Bertani, L; Russo, S; Ceccarelli, L; Costa, F; Bellini, M; Blandizzi, C; Savarino, V; Marchi, S
2016-01-01
Multichannel impedance pH monitoring has shown that weakly acidic refluxes are able to generate heartburn. However, data on the role of different pH values, ranging between 4 and 7, in the generation of them are lacking. The aim of this study was to evaluate whether different pH values of weakly acidic refluxes play a differential role in provoking reflux symptoms in endoscopy-negative patients with physiological esophageal acid exposure time and positive symptom index and symptom association probability for weakly acidic refluxes. One hundred and forty-three consecutive patients with gastroesophageal reflux disease, nonresponders to proton pump inhibitors (PPIs), were allowed a washout from PPIs before undergoing: upper endoscopy, esophageal manometry, and multichannel impedance pH monitoring. In patients with both symptom index and symptom association probability positive for weakly acidic reflux, each weakly acidic reflux was evaluated considering exact pH value, extension, physical characteristics, and correlation with heartburn. Forty-five patients with normal acid exposure time and positive symptom association probability for weakly acidic reflux were identified. The number of refluxes not heartburn related was higher than those heartburn related. In all distal and proximal liquid refluxes, as well as in distal mixed refluxes, the mean pH value of reflux events associated with heartburn was significantly lower than that not associated. This condition was not confirmed for proximal mixed refluxes. Overall, a low pH of weakly acidic reflux represents a determinant factor in provoking heartburn. This observation contributes to better understand the pathophysiology of symptoms generated by weakly acidic refluxes, paving the way toward the search for different therapeutic approaches to this peculiar condition of esophageal hypersensitivity. © 2014 International Society for Diseases of the Esophagus.
Ni, Yang; Zhou, Ying; Xu, Mingzhen; He, Xiaomeng; Li, Huqun; Haseeb, Satter; Chen, Hui; Li, Weiyong
2015-03-25
A new method for simultaneous determination of phentermine and topiramate by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching modes was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. Analyses were performed on a liquid chromatography system employing a Kromasil 60-5CN column (2.1 mm × 100 mm, 5 μm) and an isocratic elution with mixed solution of acetonitrile-20mM ammonium formate containing 0.3% formic acid (40:60, v/v), at a flow rate of 0.35 mL/min. Doxazosin mesylate and pioglitazone were used as the internal standard (IS) respectively for quantification. The determination was carried out on an API 4000 triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 150.0/91.0 for phentermine, m/z 452.1/344.3 for doxazosin, and negative m/z 338.3/77.9 for topiramate, m/z 355.0/41.9 for pioglitazone. The method was validated to be linear over the concentration range of 1-800 ng mL(-1) for phentermine, 1-1000 ng mL(-1) for topiramate. Within- and between-day accuracy and precision of the validated method at three different concentration levels were within the acceptable limits of <15% at all concentrations. Blood samples were collected into heparinized tubes before and after administration. The simple and robust LC/MS/MS method was successfully applied for the simultaneous determination of phentermine and topiramate in a pharmacokinetic study in healthy male Chinese volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.
Predictors of Self-Efficacy and Self-Rated Health for Older Male Inmates
Steffensmeier, Darrell; Kassab, Cathy
2010-01-01
Aims To examine: (1) the relationships between self-efficacy for health management and (a) health-promoting behaviors, (b) health-monitoring behaviors, and (c) self-rated health status in older male prisoners; and (2) the variations in self-rated health status and self-efficacy for health management by inmate characteristics of older men in prison. Background The graying of the inmate population around the globe can be attributed to increases in punitive crime control practices, life expectancy; and the aging baby boom generation. Older inmates are typically not a healthy group. Therefore, the needs of burgeoning numbers of older, sicker inmates are issues of international significance. Methods A descriptive, correlational, survey was conducted from late 2007 to mid-2008 with Bandura’s self-efficacy model as the guiding framework. Results/Findings Participants were 131 male inmates, age 50 and older. A significant positive relationship was found between self-efficacy for health management and the indexes measuring health-promoting behaviors (r=0.550; P<0.001), health-monitoring behaviors (r=0.323; P=0.001), and the single item rating for self-rated health (τb=0.411; P<0.001). There was a tendency for education to be positively related to self-rated health, but not self-efficacy (τb =0.140; P=0.054 and τb=0.105; P=0.122, respectively). Years of incarceration was not significantly related to self-rated health or self-efficacy. Conclusion These research findings support Bandura’s self-efficacy theoretical work and its applicability to health-related research in prisons. Nurses are front line health care providers in prison, who are in a key position to implement interventions that promote greater inmate self-efficacy for healthy behaviors and chronic disease management. PMID:21198807
75 FR 23247 - International Whaling Commission; 62nd Annual Meeting; Nominations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-03
... representing the positions of non-governmental organizations. Generally, only one non-governmental position is... representing the positions of non-governmental organizations. Generally, only one non-governmental position is... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration RIN 0648-XV73 International...
A beam position monitor for the diagnostic line in MEBT2 of J-PARC linac
NASA Astrophysics Data System (ADS)
Miura, A.; Tamura, J.; Kawane, Y.
2017-07-01
In the linac of the Japan Proton Accelerator Research Complex (J-PARC), the neutral hydrogen (H0) beam from the negative hydrogen ion (H-) beam is one of key issues in mitigating beam losses. To diagnose H0 particles, we installed a set of beam-bump magnets to generate a chicane orbit of the H- beam. The beam position monitors (BPMs) in the beam line are used for orbit correction to maintain the beam displacement within 2.0 mm from the duct center. To measure the beam displacement under different drive currents of the beam-bump magnets, a new wide-range BPM was designed and manufactured to evaluate the horizontal beam position by using a correction function to compensate for non-linearity. We also employed the beam profile monitor (WSM: wire scanner monitor) to measure the H- beam profile, which helped us to compare the beam position measurements. In this paper, the design and the performance of the wide-range BPM are described. In addition, we present a comparison of the beam position measured by the BPM and the WSM.
Brüllmann, Gregor; Fritsch, Karsten; Thurnheer, Robert; Bloch, Konrad E
2010-01-01
Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor feedback. Five healthy subjects and 12 patients with lung disease were monitored by portable RIP with sensors incorporated within a body garment. Unrestrained individuals were studied during 40-60 min while supine, sitting and upright/walking. Position was changed repeatedly every 5-10 min. Initial qualitative diagnostic calibration followed by volume scaling in absolute units during 20 breaths in different positions by flow meter provided position-specific volume-motion coefficients for RIP. These were applied during subsequent monitoring in corresponding positions according to feedback from 4 accelerometers placed at the chest and thigh. Accuracy of RIP was evaluated by face mask pneumotachography. Position sensor feedback allowed accurate adjustment of RIP calibration during repeated position changes in subjects and patients as reflected in a minor mean difference (bias) in breath-by-breath tidal volumes estimated by RIP and flow meter of 0.02 liters (not significant) and limits of agreement (+/-2 SD) of +/-19% (2,917 comparisons). An average of 10 breaths improved precision of RIP (limits of agreement +/-14%). RIP calibration incorporating position sensor feedback greatly enhances the application of RIP as a valuable, unobtrusive tool to investigate respiratory physiology and ventilatory limitation in unrestrained healthy subjects and patients with lung disease during everyday activities including position changes. Copyright 2009 S. Karger AG, Basel.
Pink Card: Tax Issues Affecting International Students, Faculty, and Staff.
ERIC Educational Resources Information Center
Somers, Patricia; And Others
1993-01-01
The Internal Revenue Service and Immigration and Naturalization Service have increased monitoring of tax withholding for international scholars. Higher education institutions and scholars alike will benefit from a thorough understanding of tax treaties, nonresident alien status, income taxation, and social security tax obligations and periodic…
77 FR 12981 - Establishment of the Interagency Trade Enforcement Center
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-05
... through strengthened and coordinated enforcement of U.S. trade rights under international trade agreements... monitoring and enforcement of U.S. rights under international trade agreements, and enforcement of domestic... our international trade agreements and under domestic trade laws. Sec. 2. Establishment. (a) There is...
Advancing internal erosion monitoring using seismic methods in field and laboratory studies
NASA Astrophysics Data System (ADS)
Parekh, Minal L.
This dissertation presents research involving laboratory and field investigation of passive and active methods for monitoring and assessing earthen embankment infrastructure such as dams and levees. Internal erosion occurs as soil particles in an earthen structure migrate to an exit point under seepage forces. This process is a primary failure mode for dams and levees. Current dam and levee monitoring practices are not able to identify early stages of internal erosion, and often the result is loss of structure utility and costly repairs. This research contributes to innovations for detection and monitoring by studying internal erosion and monitoring through field experiments, laboratory experiments, and social and political framing. The field research in this dissertation included two studies (2009 and 2012) of a full-scale earthen embankment at the IJkdijk in the Netherlands. In both of these tests, internal erosion occurred as evidenced by seepage followed by sand traces and boils, and in 2009, eventual failure. With the benefit of arrays of closely spaced piezometers, pore pressure trends indicated internal erosion near the initiation time. Temporally and spatially dense pore water pressure measurements detected two pore water pressure transitions characteristic to the development of internal erosion, even in piezometers located away from the backward erosion activity. At the first transition, the backward erosion caused anomalous pressure decrease in piezometers, even under constant or increasing upstream water level. At the second transition, measurements stabilized as backward erosion extended further upstream of the piezometers, as shown in the 2009 test. The transitions provide an indication of the temporal development and the spatial extent of backward erosion. The 2012 IJkdijk test also included passive acoustic emissions (AE) monitoring. This study analyzed AE activity over the course of the 7-day test using a grid of geophones installed on the embankment surface. Analysis of root mean squared amplitude and AE threshold counts indicated activity focused at the toe in locations matching the sand boils. This analysis also compared the various detection methods employed at the 2012 test to discuss a timeline of detection related to observable behaviors of the structure. The second area of research included designing and fabricating an instrumented laboratory apparatus for investigating active seismic wave propagation through soil samples. This dissertation includes a description of the rigid wall permeameter, instrumentation, control, and acquisitions systems along with descriptions of the custom-fabricated seismic sensors. A series of experiments (saturated sand, saturated sand with a known static anomaly placed near the center of the sample, and saturated sand with a diminishing anomaly near the center of the sample) indicated that shear wave velocity changes reflected changes in the state of stress of the soil. The mean effective stress was influenced by the applied vertical axial load, the frictional interaction between the soil and permeameter wall, and the degree of preloading. The frictional resistance was sizeable at the sidewall of the permeameter and decreased the mean effective stress with depth. This study also included flow tests to monitor changes in shear wave velocities as the internal erosion process started and developed. Shear wave velocity decreased at voids or lower density zones in the sample and increased as arching redistributes loads, though the two conditions compete. Finally, the social and political contexts surrounding nondestructive inspection were considered. An analogous approach utilized by the aerospace industry was introduced: a case study comparing the path toward adopting nondestructive tools as standard practices in monitoring aircraft safety. Additional lessons for dam and levee safety management were discussed from a Science, Technology, Engineering, and Policy (STEP) perspective.
EGNOS Monitoring Prepared in Space Research Centre P.A.S. for SPMS Project
NASA Astrophysics Data System (ADS)
Swiatek, Anna; Jaworski, Leszek; Tomasik, Lukasz
2017-12-01
The European Geostationary Overlay Service (EGNOS) augments Global Positioning System (GPS) by providing correction data and integrity information for improving positioning over Europe. EGNOS Service Performance Monitoring Support (SPMS) project has assumed establishment, maintenance and implementation of an EGNOS performance monitoring network. The paper presents preliminary results of analyses prepared in Space Research Centre, Polish Academy of Sciences (Warsaw), as one of partners in SPMS project.
Stepping-Motion Motor-Control Subsystem For Testing Bearings
NASA Technical Reports Server (NTRS)
Powers, Charles E.
1992-01-01
Control subsystem closed-loop angular-position-control system causing motor and bearing under test to undergo any of variety of continuous or stepping motions. Also used to test bearing-and-motor assemblies, motors, angular-position sensors including rotating shafts, and like. Monitoring subsystem gathers data used to evaluate performance of bearing or other article under test. Monitoring subsystem described in article, "Monitoring Subsystem For Testing Bearings" (GSC-13432).
Fayad, Hadi; Pan, Tinsu; Clément, Jean-François; Visvikis, Dimitris
2011-01-01
Purpose Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signals over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the entire patient external surface in real time. The main objective of this study was to assess the motion correlation between such an external patient surface and internal anatomical landmarks motion. Methods Four dimensional Computed Tomography (4D CT) volumes for ten patients were used in this study. Anatomical landmarks were manually selected in the thoracic region across the 4D CT datasets by two experts. The landmarks included normal structures as well as the tumour location. In addition, a distance map representing the entire external patient surface, which corresponds to surfaces acquired by a Time of Flight (ToF) camera or similar devices, was created by segmenting the skin of all 4D CT volumes using a thresholding algorithm. Finally, the correlation between the internal landmarks and external surface motion was evaluated for different regions (placement and size) throughout a patient’s surface. Results Significant variability was observed in the motion of the different parts of the external patient surface. The larger motion magnitude was consistently measured in the central regions of the abdominal and the thoracic areas for the different patient datasets considered. The highest correlation coefficients were observed between the motion of these external surface areas and internal landmarks such as the diaphragm and mediastinum structures as well as the tumour location landmarks (0.8 ± 0.18 and 0.72 ± 0.12 for the abdominal and the thoracic regions respectively). Worse correlation was observed when one considered landmarks not significantly influenced by respiratory motion such as the apex and the sternum. Discussion and conclusions There were large differences in the motion correlation observed considering different regions of interest placed over a patients’ external surface and internal anatomical landmarks. The positioning of current devices used for respiratory motion synchronization may reduce such correlation by averaging the motion over correlated and poorly correlated external regions. The potential of capturing in real-time the motion of the complete external patient surface as well as choosing the area of the surface that correlates best with the internal motion should allow reducing such variability and associated errors in both respiratory motion synchronization and subsequent motion modeling processes. PMID:21815390
Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.
Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther
2017-07-01
Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.
Neural mechanisms of mood-induced modulation of reality monitoring in schizophrenia
Subramaniam, Karuna; Ranasinghe, Kamalini G.; Mathalon, Daniel; Nagarajan, Srikantan; Vinogradov, Sophia
2017-01-01
Reality monitoring is the ability to accurately distinguish the source of self-generated information from externally-presented information. Although people with schizophrenia (SZ) show impaired reality monitoring, nothing is known about how mood state influences this higher-order cognitive process. Accordingly, we induced positive, neutral and negative mood states to test how different mood states modulate subsequent reality monitoring performance. Our findings indicate that mood affected reality monitoring performance in HC and SZ participants in both similar and dissociable ways. Only a positive mood facilitated task performance in Healthy Control (HC) subjects, whereas a negative mood facilitated task performance in SZ subjects. Yet, when both HC and SZ participants were in a positive mood, they recruited medial prefrontal cortex (mPFC) to bias better subsequent self-generated item identification, despite the fact that mPFC signal was reduced in SZ participants. Additionally, in SZ subjects, negative mood states also modulated left and right dorsal mPFC signal to bias better externally-presented item identification. Together our findings reveal that although the mPFC is hypoactive in SZ participants, mPFC signal plays a functional role in mood–cognition interactions during both positive and negative mood states to facilitate subsequent reality monitoring decision-making. PMID:28162778
Teacher Quality, Appraisal and Development: The Flaws in the IQMS
ERIC Educational Resources Information Center
De Clerq, Francine
2008-01-01
This article addresses the issue of how to monitor and develop the quality of teaching in schools by identifying the international lessons of teacher appraisal, monitoring and support systems and by interrogating the recently introduced South African Integrated Quality Management System (IQMS). The aim is to show why teacher monitoring and…
Is There a Lexical Bias Effect in Comprehension Monitoring?
ERIC Educational Resources Information Center
Severens, Els; Hartsuiker, Robert J.
2009-01-01
Event-related potentials were used to investigate if there is a lexical bias effect in comprehension monitoring. The lexical bias effect in language production (the tendency of phonological errors to result in existing words rather than nonwords) has been attributed to an internal self-monitoring system, which uses the comprehension system, and…
Sample size allocation for food item radiation monitoring and safety inspection.
Seto, Mayumi; Uriu, Koichiro
2015-03-01
The objective of this study is to identify a procedure for determining sample size allocation for food radiation inspections of more than one food item to minimize the potential risk to consumers of internal radiation exposure. We consider a simplified case of food radiation monitoring and safety inspection in which a risk manager is required to monitor two food items, milk and spinach, in a contaminated area. Three protocols for food radiation monitoring with different sample size allocations were assessed by simulating random sampling and inspections of milk and spinach in a conceptual monitoring site. Distributions of (131)I and radiocesium concentrations were determined in reference to (131)I and radiocesium concentrations detected in Fukushima prefecture, Japan, for March and April 2011. The results of the simulations suggested that a protocol that allocates sample size to milk and spinach based on the estimation of (131)I and radiocesium concentrations using the apparent decay rate constants sequentially calculated from past monitoring data can most effectively minimize the potential risks of internal radiation exposure. © 2014 Society for Risk Analysis.
Fiber optic sensor technology - An opportunity for smart aerospace structures
NASA Technical Reports Server (NTRS)
Heyman, J. S.; Rogowski, R. S.; Claus, R. O.
1988-01-01
Fiber optic sensors provide the opportunity for fabricating materials with internal sensors which can serve as lifetime health monitors, analogous to a central nervous system. The embedded fiber optic sensors can be interrogated by various techniques to measure internal strain, temperature, pressure, acoustic waves and other parameters indicative of structural integrity. Experiments have been conducted with composite samples with embedded sensors to measure strain using optical time domain reflectometry, modal interference and an optical phase locked loop. Fiber optic sensors have been developed to detect acoustic emission and impact damage and have been demonstrated for cure monitoring. These sensors have the potential for lifetime monitoring of structural properties, providing real time nondestructive evaluation.