Sample records for internal pressure evaluation

  1. Effect of Combined Loading Due to Bending and Internal Pressure on Pipe Flaw Evaluation Criteria

    NASA Astrophysics Data System (ADS)

    Miura, Naoki; Sakai, Shinsuke

    Considering a rule for the rationalization of maintenance of Light Water Reactor piping, reliable flaw evaluation criteria are essential for determining how a detected flaw will be detrimental to continuous plant operation. Ductile fracture is one of the dominant failure modes that must be considered for carbon steel piping and can be analyzed by elastic-plastic fracture mechanics. Some analytical efforts have provided various flaw evaluation criteria using load correction factors, such as the Z-factors in the JSME codes on fitness-for-service for nuclear power plants and the section XI of the ASME boiler and pressure vessel code. The present Z-factors were conventionally determined, taking conservativity and simplicity into account; however, the effect of internal pressure, which is an important factor under actual plant conditions, was not adequately considered. Recently, a J-estimation scheme, LBB.ENGC for the ductile fracture analysis of circumferentially through-wall-cracked pipes subjected to combined loading was developed for more accurate prediction under more realistic conditions. This method explicitly incorporates the contributions of both bending and tension due to internal pressure by means of a scheme that is compatible with an arbitrary combined-loading history. In this study, the effect of internal pressure on the flaw evaluation criteria was investigated using the new J-estimation scheme. The Z-factor obtained in this study was compared with the presently used Z-factors, and the predictability of the current flaw evaluation criteria was quantitatively evaluated in consideration of the internal pressure.

  2. Investigation of the design of a metal-lined fully wrapped composite vessel under high internal pressure

    NASA Astrophysics Data System (ADS)

    Kalaycıoğlu, Barış; Husnu Dirikolu, M.

    2010-09-01

    In this study, a Type III composite pressure vessel (ISO 11439:2000) loaded with high internal pressure is investigated in terms of the effect of the orientation of the element coordinate system while simulating the continuous variation of the fibre angle, the effect of symmetric and non-symmetric composite wall stacking sequences, and lastly, a stacking sequence evaluation for reducing the cylindrical section-end cap transition region stress concentration. The research was performed using an Ansys® model with 2.9 l volume, 6061 T6 aluminium liner/Kevlar® 49-Epoxy vessel material, and a service internal pressure loading of 22 MPa. The results show that symmetric stacking sequences give higher burst pressures by up to 15%. Stacking sequence evaluations provided a further 7% pressure-carrying capacity as well as reduced stress concentration in the transition region. Finally, the Type III vessel under consideration provides a 45% lighter construction as compared with an all metal (Type I) vessel.

  3. Cardiovascular simulator improvement: pressure versus volume loop assessment.

    PubMed

    Fonseca, Jeison; Andrade, Aron; Nicolosi, Denys E C; Biscegli, José F; Leme, Juliana; Legendre, Daniel; Bock, Eduardo; Lucchi, Julio Cesar

    2011-05-01

    This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Static internal pressure capacity of Hanford Single-Shell Waste Tanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Julyk, L.J.

    1994-07-19

    Underground single-shell waste storage tanks located at the Hanford Site in Richland, Washington, generate gaseous mixtures that could be ignited, challenging the structural integrity of the tanks. The structural capacity of the single-shell tanks to internal pressure is estimated through nonlinear finite-element structural analyses of the reinforced concrete tank. To determine their internal pressure capacity, designs for both the million-gallon and the half-million-gallon tank are evaluated on the basis of gross structural instability.

  5. Study on loading path optimization of internal high pressure forming process

    NASA Astrophysics Data System (ADS)

    Jiang, Shufeng; Zhu, Hengda; Gao, Fusheng

    2017-09-01

    In the process of internal high pressure forming, there is no formula to describe the process parameters and forming results. The article use numerical simulation to obtain several input parameters and corresponding output result, use the BP neural network to found their mapping relationship, and with weighted summing method make each evaluating parameters to set up a formula which can evaluate quality. Then put the training BP neural network into the particle swarm optimization, and take the evaluating formula of the quality as adapting formula of particle swarm optimization, finally do the optimization and research at the range of each parameters. The results show that the parameters obtained by the BP neural network algorithm and the particle swarm optimization algorithm can meet the practical requirements. The method can solve the optimization of the process parameters in the internal high pressure forming process.

  6. Personalized modeling for real-time pressure ulcer prevention in sitting posture.

    PubMed

    Luboz, Vincent; Bailet, Mathieu; Boichon Grivot, Christelle; Rochette, Michel; Diot, Bruno; Bucki, Marek; Payan, Yohan

    2018-02-01

    Ischial pressure ulcer is an important risk for every paraplegic person and a major public health issue. Pressure ulcers appear following excessive compression of buttock's soft tissues by bony structures, and particularly in ischial and sacral bones. Current prevention techniques are mainly based on daily skin inspection to spot red patches or injuries. Nevertheless, most pressure ulcers occur internally and are difficult to detect early. Estimating internal strains within soft tissues could help to evaluate the risk of pressure ulcer. A subject-specific biomechanical model could be used to assess internal strains from measured skin surface pressures. However, a realistic 3D non-linear Finite Element buttock model, with different layers of tissue materials for skin, fat and muscles, requires somewhere between minutes and hours to compute, therefore forbidding its use in a real-time daily prevention context. In this article, we propose to optimize these computations by using a reduced order modeling technique (ROM) based on proper orthogonal decompositions of the pressure and strain fields coupled with a machine learning method. ROM allows strains to be evaluated inside the model interactively (i.e. in less than a second) for any pressure field measured below the buttocks. In our case, with only 19 modes of variation of pressure patterns, an error divergence of one percent is observed compared to the full scale simulation for evaluating the strain field. This reduced model could therefore be the first step towards interactive pressure ulcer prevention in a daily set-up. Copyright © 2017 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  7. Stress and Sealing Performance Analysis of Containment Vessel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WU, TSU-TE

    2005-05-24

    This paper presents a numerical technique for analyzing the containment vessel subjected to the combined loading of closure-bolt torque and internal pressure. The detailed stress distributions in the O-rings generated by both the torque load and the internal pressure can be evaluated by using this method. Consequently, the sealing performance of the O-rings can be determined. The material of the O-rings can be represented by any available constitutive equation for hyperelastic material. In the numerical calculation of this paper, the form of the Mooney-Rivlin strain energy potential is used. The technique treats both the preloading process of bolt tightening andmore » the application of internal pressure as slow dynamic loads. Consequently, the problem can be evaluated using explicit numerical integration scheme.« less

  8. Evaluation of the Carefusion Alaris PC infusion pump for hyperbaric oxygen therapy conditions: Technical report.

    PubMed

    Smale, Andrew; Tsouras, Theo

    2017-01-01

    We present a standardized test methodology and results for our evaluation of the Carefusion Alaris PC infusion pump, comprising the model 8015 PC Unit and the model 8100 Large Volume Pump (LVP) module. The evaluation consisted of basic suitability testing, internal component inspection, surface temperature measurement of selected internal components, and critical performance testing (infusion rate accuracy and occlusion alarm pressure) during conditions of typical hyperbaric oxygen (HBO₂) treatment in our facility's class A multiplace chamber. We have found that the pumps pose no enhanced risk as an ignition source, and that the pumps operate within manufacturer's specifications for flow rate and occlusion alarms at all stages of HBO₂ treatments, up to 4.0 ATA and pressurization and depressurization rates up to 180 kPa/minute. The pumps do not require purging with air or nitrogen and can be used unmodified, subject to the following conditions: pumps are undamaged, clean, fully charged, and absent from alcohol cleaning residue; pumps are powered from the internal NiMH battery only; maximum pressure exposure 4.0 ATA; maximum pressurization and depressurization rate of 180 kPa/minute; LVP modules locked in place with retaining screws. Copyright© Undersea and Hyperbaric Medical Society.

  9. Capacity Loss Studies on High Capacity Li-ion Cells for the Orbiter Advanced Hydraulic Power System

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Irlbeck, Bradley W.

    2004-01-01

    Contents include the following: Introduction. Physical and electrochemical characteristics. Performance evaluation. Rate performance. Internal resistance. Performance at different temperatures. Safety evaluation. Overcharge. Overdischarge. External short. Simulated internal short. Heat-to-vent. Vibration. Drop rest. Vent and burst pressure.

  10. Space Shuttle Redesigned Solid Rocket Motor nozzle natural frequency variations with burn time

    NASA Technical Reports Server (NTRS)

    Lui, C. Y.; Mason, D. R.

    1991-01-01

    The effects of erosion and thermal degradation on the Space Shuttle Redesigned Solid Rocket Motor (RSRM) nozzle's structural dynamic characteristics were analytically evaluated. Also considered was stiffening of the structure due to internal pressurization. A detailed NASTRAN finite element model of the nozzle was developed and used to evaluate the influence of these effects at several discrete times during motor burn. Methods were developed for treating erosion and thermal degradation, and a procedure was developed to account for internal pressure stiffening using differential stiffness matrix techniques. Results were verified using static firing test accelerometer data. Fast Fourier Transform and Maximum Entropy Method techniques were applied to the data to generate waterfall plots which track modal frequencies with burn time. Results indicate that the lower frequency nozzle 'vectoring' modes are only slightly affected by erosion, thermal effects and internal pressurization. The higher frequency shell modes of the nozzle are, however, significantly reduced.

  11. High Stability Metal-Protein Interactions Evaluated by Microcalorimetry

    DTIC Science & Technology

    2016-04-29

    microprocessor -controlled internal vacuum pump runs for a 90 second period, then it evaluates the vacuum pressure attained, and if that value meets spec...and the other with the software. There is a place in the wash module program where the ITC’s microprocessor - controlled internal vacuum pump runs for

  12. Subatmospheric vapor pressures evaluated from internal-energy measurements

    NASA Astrophysics Data System (ADS)

    Duarte-Garza, H. A.; Magee, J. W.

    1997-01-01

    Vapor pressures were evaluated from measured internal-energy changes in the vapor+liquid two-phase region, Δ U (2). The method employed a thermodynamic relationship between the derivative quantity (ϖ U (2)/ϖ V) T and the vapor pressure ( p σ) and its temperature derivative (ϖ p/ϖ T)σ. This method was applied at temperatures between the triple point and the normal boiling point of three substances: 1,1,1,2-tetrafluoroethane (R134a), pentafluoroethane (R125), and difluoromethane (R32). Agreement with experimentally measured vapor pressures near the normal boiling point (101.325 kPa) was within the experimental uncertainty of approximately ±0.04 kPa (±0.04%). The method was applied to R134a to test the thermodynamic consistency of a published p-p-T equation of state with an equation for p σ for this substance. It was also applied to evaluate published p σ data which are in disagreement by more than their claimed uncertainty.

  13. Internal coating of air cooled gas turbine blades

    NASA Technical Reports Server (NTRS)

    Ahuja, P. L.

    1979-01-01

    Six coating systems were evaluated for internal coating of decent stage (DS) eutectic high pressure turbine blades. Sequential deposition of electroless Ni by the hydrazine process, slurry Cr, and slurry Al, followed by heat treatment provided the coating composition and thickness for internal coating of DS eutectic turbine blades. Both NiCr and NiCrAl coating compositions were evaluated for strain capability and ductile to brittle transition temperature.

  14. Simulation and evaluation of rupturable coated capsules by finite element method.

    PubMed

    Yang, Yan; Fang, Jie; Shen, Lian; Shan, Weiguang

    2017-03-15

    The objective of this study was to simulate and evaluate the burst behavior of rupturable coated capsules by finite element method (FEM). Film and coated capsules were prepared by dip-coating method and their dimensions were determined by stereomicroscope. Mechanical properties of the film were measured by tensile test and used as material properties of FEM models. Swelling pressure was determined by restrained expansion method and applied to the internal surface of FEM models. Water uptake of coated capsules was determined to study the formation of internal pressure. Burst test and in vitro dissolution was used to verify the FEM models, which were used to study and predict the coating burst behavior. Simulated results of coating burst behavior were well agreed with the experiment results. Swelling pressure, material properties and dimensions of coating had influence on the maximum stress. Burst pressure and critical L-HPC content were calculated for burst prediction and formulation optimization. FEM simulation was a feasible way to simulate and evaluate the burst behavior of coated capsules. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A study of the eigenvectors of low frequency vibrational modes in crystalline cytidine via high pressure Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Lee, Scott A.

    2014-03-01

    High-pressure Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the low-frequency vibrational modes of crystalline cytidine at 295 K by evaluating the logarithmic derivative of the vibrational frequency with respect to pressure: 1/ω dω/dP. Crystalline samples of molecular materials such as cytidine have vibrational modes that are localized within a molecular unit (``internal'' modes) as well as modes in which the molecular units vibrate against each other (``external'' modes). The value of the logarithmic derivative is a diagnostic probe of the nature of the eigenvector of the vibrational modes, making high pressure experiments a very useful probe for such studies. Internal stretching modes have low logarithmic derivatives while external as well as internal torsional and bending modes have higher logarithmic derivatives. All of the Raman modes below 200 cm-1 in cytidine are found to have high logarithmic derivatives, consistent with being either external modes or internal torsional or bending modes.

  16. Isochoric Burn, an Internally Consistent Method for the Reactant to Product Transformation in Reactive Flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reaugh, J E; Lee, E L

    2002-07-01

    Mixture rules for partially reacted explosives differ amongst various models. For instance, JWL++ uses a partial pressure addition to compute an average zonal pressure, Ignition and Growth requires pressure equilibration and thermal equilibration of temperature dependent JWL EOSs, CHEETAH In Line RF also assumes temperature and pressure equilibration. It has been suggested in the past that a more realistic equilibration scheme should comprise isentropic pressure equilibration of the separate reacted and unreacted phases. This turns out not to be a proper path for equilibration. Rather, we find that the only internally consistent method is the evaluation of the equilibrium pressuremore » that satisfies the particular conditions of reactant and product resulting from deflagration in a fixed volume.« less

  17. New laser soldering-based closures: a promising method in natural orifice transluminal endoscopic surgery.

    PubMed

    Bogni, Serge; Ortner, Maria-Anna; Vajtai, Istvan; Jost, Christian; Reinert, Michael; Dallemagne, Bernard; Frenz, Martin

    2012-07-01

    Complete closure of gastrotomy is the linchpin of safe natural orifice transgastric endoscopic surgery. To evaluate feasibility and efficacy of a new method of gastrotomy closure by using a sutureless laser tissue-soldering (LTS) technique in an ex vivo porcine stomach. In vitro experiment. Experimental laboratory. Histological analysis and internal and external liquid pressure with and without hydrochloric acid exposure were determined comparing gastrotomy closure with LTS and with hand-sewn surgical sutures. Comparison of LTS and hand-sewn surgical gastrotomy closure. The primary outcome parameter was the internal leak pressure. Secondary parameters were the difference between internal and external leak pressures, the impact of an acid environment on the device, histological changes, and feasibility of endoscopic placement. The internal liquid leak pressure after LTS was almost twice as high as after hand-sewn surgical closure (416 ± 53 mm Hg vs 229 ± 99 mm Hg; P = .01). The internal leak pressure (416 ± 53 mm Hg) after LTS was higher than the external leak pressure (154 ± 46 mm Hg; P < .0001). An acidic environment did not affect leak pressure after LTS. Endoscopic LTS closure was feasible in all experiments. Histopathology revealed only slight alterations beneath the soldering plug. In vitro experiments. Leak pressure after LTS closure of gastrotomy is higher than after hand-sewn surgical closure. LTS is a promising technique for closure of gastrotomies and iatrogenic perforations. Further experiments, in particular survival studies, are mandatory. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Stress analysis and evaluation of a rectangular pressure vessel

    NASA Astrophysics Data System (ADS)

    Rezvani, M. A.; Ziada, H. H.; Shurrab, M. S.

    1992-10-01

    This study addresses structural analysis and evaluation of an abnormal rectangular pressure vessel, designed to house equipment for drilling and collecting samples from Hanford radioactive waste storage tanks. It had to be qualified according to ASME boiler and pressure vessel code, section 8; however, it had the cover plate bolted along the long face, a configuration not addressed by the code. Finite element method was used to calculate stresses resulting from internal pressure; these stresses were then used to evaluate and qualify the vessel. Fatigue is not a concern; thus, it can be built according to section 8, division 1 instead of division 2. Stress analysis was checked against the code. A stayed plate was added to stiffen the long side of the vessel.

  19. Terahertz NDE of Stressed Composite Overwrapped Pressure Vessels - Initial Testing

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Seebo, Jeffrey P.; Anatasi, Robert F.

    2009-01-01

    Terahertz radiation nondestructive evaluation was applied to a set of Kevlar composite overwrapped pressure vessel bottles that had undergone a series of thermal and pressure tests to simulate stress rupture effects. The bottles in these nondestructive evaluation tests were bottles that had not ruptured but had survived various times at the elevated load and temperature levels. Some of the bottles showed evidence of minor composite failures. The terahertz radiation did detect visible surface flaws, but did not detect any internal chemical or material degradation of the thin overwraps.

  20. Subatmospheric vapor pressures for fluoromethane (R41), 1,1-difluoroethane (R152a), and 1,1,1-trifluoroethane (R143a) evaluated from internal-energy measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duarte-Garza, H.A.; Magee, J.W.

    1999-09-01

    Vapor pressures were evaluated from measured internal-energy changes {Delta}U{sup (2)} in the vapor + liquid two-phase region. The method employed a thermodynamic relationship between the derivative quantity ({partial_derivative}U{sup (2)}/{partial_derivative}V){sub T}, the vapor pressure p{sub {sigma}}, and its temperature derivative ({partial_derivative}p/{partial_derivative}T){sub {sigma}}. This method was applied at temperatures between the triple point and the normal boiling point of three substances: fluoromethane (R41), 1,1-difluoroethane (R152a), and 1,1,1-trifluoroethane (R143a). In the case of R41, vapor pressures up to 1 MPa were calculated to validate the technique at higher pressures. For R152a, the calculated vapor pressure at the triple-point temperature differed from a directmore » experimental measurement by less than the claimed uncertainty (5 Pa) of the measurement. The calculated vapor pressures for R41 helped to resolve discrepancies in several published vapor pressure sources. Agreement with experimentally measured vapor pressures for R152a and for R143a near the normal boiling point (101.325 kPa) was within the experimental uncertainty of approximately 0.04 kPa (0.04%) for the published measurements.« less

  1. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  2. The effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss. [acoustic propagation through aircraft fuselage

    NASA Technical Reports Server (NTRS)

    Koval, L. R.

    1975-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. These effects are incorporated into the classical equations for the TL of single panels, and the resulting double integral for field-incidence TL is numerically evaluated for a specific set of parameters.

  3. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    PubMed

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  4. Initial evaluation tests of General Electric Company 12.0 ampere hour nickel cadmium spacecraft cells with design variables

    NASA Technical Reports Server (NTRS)

    Harkness, J. D.

    1979-01-01

    All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.

  5. Evaluation and Development of Administrators. AAHE-ERIC/Higher Education Research Report No. 6, 1979.

    ERIC Educational Resources Information Center

    Nordvall, Robert C.

    Needs and methods for the evaluation and development of higher education administrators are reviewed in this monograph. Three major reasons for evaluation are cited: external and internal pressure, improvement of performance of individual administrators, and improvement of performance of the institution. Different approaches to evaluation are…

  6. Internal Thermal Control System Hose Heat Transfer Fluid Thermal Expansion Evaluation Test Report

    NASA Technical Reports Server (NTRS)

    Wieland, P. O.; Hawk, H. D.

    2001-01-01

    During assembly of the International Space Station, the Internal Thermal Control Systems in adjacent modules are connected by jumper hoses referred to as integrated hose assemblies (IHAs). A test of an IHA has been performed at the Marshall Space Flight Center to determine whether the pressure in an IHA filled with heat transfer fluid would exceed the maximum design pressure when subjected to elevated temperatures (up to 60 C (140 F)) that may be experienced during storage or transportation. The results of the test show that the pressure in the IHA remains below 227 kPa (33 psia) (well below the 689 kPa (100 psia) maximum design pressure) even at a temperature of 71 C (160 F), with no indication of leakage or damage to the hose. Therefore, based on the results of this test, the IHA can safely be filled with coolant prior to launch. The test and results are documented in this Technical Memorandum.

  7. The changes in resting anal pressure after performing full-thickness rectal advancement flaps.

    PubMed

    Balciscueta, Zutoia; Uribe, Natalia; Mínguez, Miguel; García-Granero, Eduardo

    2017-09-01

    Advancement flap is an accepted approach for treating complex fistula-in-ano.The purpose was to evaluate the changes in resting pressure along the anal canal after performing a full-thickness flap. Manometric review of patients who have undergone a full-thickness rectal advancement flap procedure for complex anal fistulas of cryptoglandular origin. Recurrence and continence were evaluated. Resting Anal Pressure was assessed along the anal canal by two measures: maximum resting pressure(MRP) and inferior resting pressure(IRP) at 0.5 cm from the anal verge. 119 patients were evaluated. Overall recurrence rate was5.9%. Anal continence was maintained intact in 76.5%. Manometric study showed a significant decrease in postoperative MRP(90.6 ± 31.9 to 45.2 ± 20 mmHg; p < 0.001), while IRP values did not differ significantly(28.2 ± 18.3 to 23.2 ± 13.5 mmHg; p = 0.1). Performing a full-thickness rectal flap causes a decrease of the MRP in the middle third of the anal canal, due to the inclusion of the internal sphincter in flap. It seems crucial to preserve the distal internal sphincter intact as it helps both to maintain the resting pressure in the lower third and avoid deformities of the anal margin. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. The Use of Superselective Arteriography in the Evaluation of the Influence of Intracapsular Hip Joint Pressure on the Blood Flow of the Femoral Head.

    PubMed

    Wu, Kai; Huang, Jianhua; Wang, Qiugen

    2016-01-01

    We aimed to analyze the intracapsular pressure of the hip joint following femoral neck fracture and its relationship to the position of the hip or to traction and (using superselective arteriography) to evaluate the blood supply to the femoral head and the influence of traction and hip position on the blood supply. Twenty-six cases of fresh Garden type I-III femoral neck fractures were enrolled. After being placed in the neutral position, in internal rotation or with traction of 3 and 5 kg, respectively, intracapsular manometric changes were measured. Eight cases underwent superselective arteriography of the medial circumflex femoral artery and its branches under the manometric changes of the hip joint capsule. Twenty-four to 48 h after the injury, the intracapsular pressure was significantly higher on the fractured side than on the normal side. The mean pressure was 28.41 ± 9.339 mm Hg in fully extended hips in the neutral position, 79.92 ± 12.80 mm Hg in internally rotated hips, 51.39 ± 15.41 mm Hg in hips with 3 kg of traction and 64.81 ± 13.56 mm Hg in hips with 5 kg of traction. The arteriographic findings revealed that traction and internal rotation reduced the perfusion of the femoral head at the medial circumflex femoral artery and its branches, and also negatively influenced venous reflux. Traction and internal rotation both caused the intracapsular pressure of the hip joint to rise considerably, which reduced the femoral head perfusion and impeded venous reflux. This could lead to avascular necrosis of the femoral head. © 2015 S. Karger AG, Basel.

  9. Closing the Learning Loop: A Review of Assignments in International Business Education

    ERIC Educational Resources Information Center

    Seno-Alday, Sandra; Budde-Sung, Amanda

    2016-01-01

    The continuing rapid globalization has significantly changed the nature of business and management, leading to increased pressure from a wide range of stakeholders to globalize business schools and to internationalize business curricula. This comes with a corresponding imperative to rigorously evaluate the impact of an international business…

  10. Catholic Social Teaching Should Permeate the Catholic Secondary School Curriculum: An Agenda for Reform

    ERIC Educational Resources Information Center

    Grace, Gerald

    2013-01-01

    International research shows that the curricula of Catholic secondary schools are increasingly becoming dominated by the pressures of conforming to the requirements of nation states. These requirements are generally expressed in economic and utilitarian terms and evaluated by criteria of measurable outputs. As a result of these pressures, Catholic…

  11. Psychometric properties of the Sociocultural Attitudes Towards Appearance Questionnaire-4 (SATAQ-4) in French women and men.

    PubMed

    Rodgers, Rachel F; Schaefer, Lauren M; Thompson, J Kevin; Girard, Marilou; Bertrand, Mélanie; Chabrol, Henri

    2016-06-01

    This study evaluated the psychometric properties of the Sociocultural Attitudes Towards Appearance Questionnaire-4 (SATAQ-4), a measure of internalization of societal appearance ideals, in French men and women. French college students completed a translation of the 22-item SATAQ-4 and measures of body image and eating concerns. Exploratory analyses among women (N=207) indicated a 20-item scale with the original five factors: Internalization: Thin/Low Body Fat, Internalization: Muscular/Athletic, Pressures: Family, Pressures: Media, Pressures: Peers. This structure was confirmed among a second sample of women (N=227). The SATAQ-4 scores revealed excellent reliability and convergent validity with body image and eating concern scores. A slightly modified factor structure emerged in men, with excellent reliability. Among men, the SATAQ-4 subscales were consistently associated with eating, and shape and weight concerns, although less consistently with general measures of body image. The French SATAQ-4 is a useful measure of internalization of appearance ideals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  13. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  14. GATEWAY Report Brief: SSL Evaluation: Philadelphia International Airport Apron Lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    Summary of report that documents a trial installation of LED apron lighting that replaced the existing high-pressure sodium luminaires at Philadelphia International Airport. Such high-mast applications remain challenging for LED technology, and the lessons learned from this project may help facility managers and LED product manufacturers better meet those challenges.

  15. Results for the Aboveground Configuration of the Boiling Water Reactor Dry Cask Simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durbin, Samuel G.; Lindgren, Eric Richard

    The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and also by increasing themore » internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of the current investigation was to produce data sets that can be used to test the validity of the assumptions associated with the calculations used to determine steady-state cladding temperatures in modern dry casks that utilize elevated helium pressure in the sealed canister in an aboveground configuration. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. The arrangement of ducting was used to mimic conditions for an aboveground storage configuration in a vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured for a wide range of decay power and helium cask pressures. Of particular interest was the evaluation of the effect of increased helium pressure on peak cladding temperatures (PCTs) for identical thermal loads. All steady state peak temperatures and induced flow rates increased with increasing assembly power. Peak cladding temperatures decreased with increasing internal helium pressure for a given assembly power, indicating increased internal convection. In addition, the location of the PCT moved from near the top of the assembly to ~1/3 the height of the assembly for the highest (8 bar absolute) to the lowest (0 bar absolute) pressure studied, respectively. This shift in PCT location is consistent with the varying contribution of convective heat transfer proportional with of internal helium pressure.« less

  16. A systematic approach to designing reliable VV optimization methodology: assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy.

    PubMed

    Kyriacou, Andreas; Li Kam Wa, Matthew E; Pabari, Punam A; Unsworth, Beth; Baruah, Resham; Willson, Keith; Peters, Nicholas S; Kanagaratnam, Prapa; Hughes, Alun D; Mayet, Jamil; Whinnett, Zachary I; Francis, Darrel P

    2013-08-10

    In atrial fibrillation (AF), VV optimization of biventricular pacemakers can be examined in isolation. We used this approach to evaluate internal validity of three VV optimization methods by three criteria. Twenty patients (16 men, age 75 ± 7) in AF were optimized, at two paced heart rates, by LVOT VTI (flow), non-invasive arterial pressure, and ECG (minimizing QRS duration). Each optimization method was evaluated for: singularity (unique peak of function), reproducibility of optimum, and biological plausibility of the distribution of optima. The reproducibility (standard deviation of the difference, SDD) of the optimal VV delay was 10 ms for pressure, versus 8 ms (p=ns) for QRS and 34 ms (p<0.01) for flow. Singularity of optimum was 85% for pressure, 63% for ECG and 45% for flow (Chi(2)=10.9, p<0.005). The distribution of pressure optima was biologically plausible, with 80% LV pre-excited (p=0.007). The distributions of ECG (55% LV pre-excitation) and flow (45% LV pre-excitation) optima were no different to random (p=ns). The pressure-derived optimal VV delay is unaffected by the paced rate: SDD between slow and fast heart rate is 9 ms, no different from the reproducibility SDD at both heart rates. Using non-invasive arterial pressure, VV delay optimization by parabolic fitting is achievable with good precision, satisfying all 3 criteria of internal validity. VV optimum is unaffected by heart rate. Neither QRS minimization nor LVOT VTI satisfy all validity criteria, and therefore seem weaker candidate modalities for VV optimization. AF, unlinking interventricular from atrioventricular delay, uniquely exposes resynchronization concepts to experimental scrutiny. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Assessment of common interventions and perceived barriers to pressure ulcer prevention in southwest Nigeria.

    PubMed

    Ilesanmi, Rose Ekama; Olabisi, Prisca

    2014-01-01

    We examined the interventions used by nurses to prevent pressure ulcers in 3 hospitals in south west Nigeria and perceived barriers to effective nursing pressure ulcer prevention interventions. One hundred ninety-three nurses were purposively selected from neurological, orthopedic, intensive care, and accident and emergency units of participating hospitals. Study sites were 3 teaching hospitals in south west Nigeria (Lagos State University Teaching Hospital, Lagos; University College Hospital, Ibadan; and Obafemi Awolowo Teaching Hospital Ile-Ife). Data were collected via a structured questionnaire designed for this study. It included 3 sections: demographic information, practices used for pressure ulcer prevention, and perceived barriers to prevention. Sections of the questionnaire that queried interventions and perceived barriers to pressure ulcer prevention were evaluated for face and content validity. Reliability was evaluated via internal consistency; the split half reliability was 0.82. Similar practices regarding pressure ulcer prevention were found across the 3 hospitals. The most commonly used intervention was patient repositioning every 2 hours; the least used intervention was completion of a validated pressure ulcer risk scale. Nurses described using interventions that have not proved effective for pressure ulcer prevention such as massaging bony prominences and application of talcum powder. Nurses identified 2 principal factors that act as barriers to successful prevention of pressure ulcers: inadequate manpower and inadequate supply of linens on the wards. Nurses use a combination of evidence-based interventions, along with interventions that have not proved effective for pressure ulcer prevention. We recommend development of national standards for pressure ulcer prevention in Nigeria that are based on current best evidence and consistent with current international guidelines.

  18. On the Health Risk of the Lumbar Spine due to Whole-Body VIBRATION—THEORETICAL Approach, Experimental Data and Evaluation of Whole-Body Vibration

    NASA Astrophysics Data System (ADS)

    Seidel, H.; Blüthner, R.; Hinz, B.; Schust, M.

    1998-08-01

    The guidance on the effects of vibration on health in standards for whole-body vibration (WBV) does not provide quantitative relationships between WBV and health risk. The paper aims at the elucidation of exposure-response relationships. An analysis of published data on the static and dynamic strength of vertebrae and bone, loaded with various frequencies under different conditions, provided the basis for a theoretical approach to evaluate repetitive loads on the lumbar spine (“internal loads”). The approach enabled the calculation of “equivalent”—with respect to cumulative fatigue failure—combinations of amplitudes and numbers of internal cyclic stress. In order to discover the relation between external peak accelerations at the seat and internal peak loads, biodynamic data of experiments (36 subjects, three somatotypes, two different postures—relaxed and bent forward; random WBV,aw, r.m.s. 1·4 ms-2, containing high transients) were used as input to a biomechanical model. Internal pressure changes were calculated using individual areas of vertebral endplates. The assessment of WBV was based on the quantitative relations between peak accelerations at the seat and pressures predicted for the disk L5/S1. For identical exposures clearly higher rates of pressure rise in the bent forward compared to the relaxed posture were predicted. The risk assessment for internal forces considered the combined internal static and dynamic loads, in relation to the predicted individual strength, and Miner's hypothesis. For exposure durations between 1 min and 8 h, energy equivalent vibration magnitudes (formula B.1, ISO 2631-1, 1997) and equivalent vibration magnitudes according to formula B.2 (time dependence over-energetic) were compared with equivalent combinations of upward peak accelerations and exposure durations according to predicted cumulative fatigue failures of lumbar vertebrae. Formula B.1 seems to underestimate the health risk caused by high magnitudes, formula B.2 is recommended for the evaluation of such conditions.

  19. Ultrasonic Nondestructive Evaluation of PRSEUS Pressure Cube Article in Support of Load Test to Failure

    NASA Technical Reports Server (NTRS)

    Johnston, Patrick H.

    2013-01-01

    The PRSEUS Pressure Cube Test was a joint development effort between the Boeing Company and NASA Langley Research Center, sponsored in part by the Environmentally Responsible Aviation Project and Boeing internal R&D. This Technical Memorandum presents the results of ultrasonic inspections in support of the PRSEUS Pressure Cube Test, and is a companion document with the NASA test report and a report on the acoustic emission measurements made during the test.

  20. Internal performance predictions for Langley scramjet engine module

    NASA Technical Reports Server (NTRS)

    Pinckney, S. Z.

    1978-01-01

    A one dimensional theoretical method for the prediction of the internal performance of a scramjet engine is presented. The effects of changes in vehicle forebody flow parameters and characteristics on predicted thrust for the scramjet engine were evaluated using this method, and results are presented. A theoretical evaluation of the effects of changes in the scramjet engine's internal parameters is also presented. Theoretical internal performance predictions, in terms thrust coefficient and specific impulse, are provided for the scramjet engine for free stream Mach numbers of 5, 6, and 7 free stream dynamic pressure of 23,940 N/sq m forebody surface angles of 4.6 deg to 14.6 deg, and fuel equivalence ratio of 1.0.

  1. Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding.

    PubMed

    Haraldsson, Henrik; Kefayati, Sarah; Ahn, Sinyeob; Dyverfeldt, Petter; Lantz, Jonas; Karlsson, Matts; Laub, Gerhard; Ebbers, Tino; Saloner, David

    2018-04-01

    To measure the Reynolds stress tensor using 4D flow MRI, and to evaluate its contribution to computed pressure maps. A method to assess both velocity and Reynolds stress using 4D flow MRI is presented and evaluated. The Reynolds stress is compared by cross-sectional integrals of the Reynolds stress invariants. Pressure maps are computed using the pressure Poisson equation-both including and neglecting the Reynolds stress. Good agreement is seen for Reynolds stress between computational fluid dynamics, simulated MRI, and MRI experiment. The Reynolds stress can significantly influence the computed pressure loss for simulated (eg, -0.52% vs -15.34% error; P < 0.001) and experimental (eg, 306 ± 11 vs 203 ± 6 Pa; P < 0.001) data. A 54% greater pressure loss is seen at the highest experimental flow rate when accounting for Reynolds stress (P < 0.001). 4D flow MRI with extended motion-encoding enables quantification of both the velocity and the Reynolds stress tensor. The additional information provided by this method improves the assessment of pressure gradients across a stenosis in the presence of turbulence. Unlike conventional methods, which are only valid if the flow is laminar, the proposed method is valid for both laminar and disturbed flow, a common presentation in diseased vessels. Magn Reson Med 79:1962-1971, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    PubMed

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  3. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  4. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  5. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  6. Evaluation of wind-induced internal pressure in low-rise buildings: A multi scale experimental and numerical approach

    NASA Astrophysics Data System (ADS)

    Tecle, Amanuel Sebhatu

    Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30--40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30--40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.

  7. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  8. 75 FR 28074 - Advisory Committee on Reactor Safeguards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-19

    ..., 2009, (74 FR 52829-52830). Wednesday, June 9, 2010, Conference Room T2-B1, Two White Flint North... Regulatory Guide (RG) 1.216, ``Containment Structural Integrity Evaluation for Internal Pressure Loadings... representatives of the NRC staff regarding draft final RG 1.216, ``Containment Structural Integrity Evaluation for...

  9. Validation of the YuWell YE690A upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Chen, Qi; Lei, Lei; Li, Yan; Wang, Ji-Guang

    2017-10-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor YuWell YE690A for blood pressure measurement according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese (12 women, 44.2 years of mean age) using a mercury sphygmomanometer (two observers) and the YE690A device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The YuWell YE690A device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 79/99, 96/99, and 97/99, respectively, for systolic blood pressure and 72/99, 95/99, and 98/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Thirty-one and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant for systolic and two participants for diastolic blood pressure had all the three device-observer comparisons greater than 5 mmHg. The YuWell blood pressure monitor YE690A has passed the requirements of the International Protocol revision 2010 and hence can be recommended for blood pressure measurement in adults.

  10. Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Bilo, Grzegorz; Zorzi, Cristina; Ochoa Munera, Juan E; Torlasco, Camilla; Giuli, Valentina; Parati, Gianfranco

    2015-10-01

    The present study aimed to evaluate the accuracy of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults (11 women, mean age 63.5±11.9 years) using a mercury sphygmomanometer (two observers) and the Somnotouch-NIBP device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the validation requirements were fulfilled. The Somnotouch-NIBP device fulfilled the requirements of the part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 75/99, 90/99, and 96/99, respectively, for systolic blood pressure and 90/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-seven and 31 participants had at least two of the three device-observers differences less than or equal to 5 mmHg for systolic and diastolic blood pressure, respectively. All three device-observer differences were greater than 5 mmHg in two participants for systolic and in one participant for diastolic blood pressure. The Somnotouch-NIBP noninvasive continuous blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure monitoring in adults, at least under conditions corresponding to those investigated in our study.

  11. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bill Bruce; Nancy Porter; George Ritter

    2005-07-20

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, undermore » congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. In lieu of a field installation on an abandoned pipeline, a preliminary nondestructive testing protocol is being developed to determine the success or failure of the fiber-reinforced liner pipeline repairs. Optimization and validation activities for carbon-fiber repair methods are ongoing.« less

  12. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-12-31

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, undermore » congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. The first round of optimization and validation activities for carbon-fiber repairs are complete. Development of a comprehensive test plan for this process is recommended for use in the field trial portion of this program.« less

  13. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-08-17

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, undermore » congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. Development of a comprehensive test plan for this process is recommended for use in the field trial portion of this program.« less

  14. Towards international consensus on patient harm: perspectives on pressure injury policy.

    PubMed

    Jackson, Debra; Hutchinson, Marie; Barnason, Susan; Li, William; Mannix, Judy; Neville, Stephen; Piper, Donella; Power, Tamara; Smith, Graeme D; Usher, Kim

    2016-10-01

    To analyse influential policies that inform practice related to pressure injury management in Australia, England, Hong Kong, New Zealand, Scotland and the United States of America. Pressure injuries are associated with significant harm to patients, and carry economic consequences for the health sector. Internationally, preventing and managing pressure injuries is a key nursing activity and quality indicator. Comparative review and synthesis of pressure injury policies that inform practice. The predominant focus of policy is on patient risk assessment, compliance with documentation and pressure relief. Financial penalty for institutions is emerging as a strategy where pressure injuries occur. Comparisons of prevalence rates are hampered by the lack of consensus on data collection and reporting. To date there has been little evaluation of policy implementation and implemented policy strategies, associated guidelines remain founded upon expert opinion and low-level evidence. The pressure injury policy agenda has fostered a discourse of attention to incidents, compliance and penalty (sanctions). Prevention and intervention strategies are informed by technical and biomedical interpretations of patient risk and harm, with little attention given to the nature or design of nursing work. Considerable challenges remain if this policy agenda is successfully to eliminate pressure injury as a source of patient harm. © 2016 John Wiley & Sons Ltd.

  15. Analytical Investigation of Elastic Thin-Walled Cylinder and Truncated Cone Shell Intersection Under Internal Pressure.

    PubMed

    Zamani, J; Soltani, B; Aghaei, M

    2014-10-01

    An elastic solution of cylinder-truncated cone shell intersection under internal pressure is presented. The edge solution theory that has been used in this study takes bending moments and shearing forces into account in the thin-walled shell of revolution element. The general solution of the cone equations is based on power series method. The effect of cone apex angle on the stress distribution in conical and cylindrical parts of structure is investigated. In addition, the effect of the intersection and boundary locations on the circumferential and longitudinal stresses is evaluated and it is shown that how quantitatively they are essential.

  16. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT).

    PubMed

    Topouchian, Jirar A; El Assaad, Mohamed A; Orobinskaia, Ludmila V; El Feghali, Ramzi N; Asmar, Roland G

    2006-06-01

    Two electronic devices for self-measurement of blood pressure - a brachial monitor, the Omron M6, and a wrist monitor, the Omron R7 - were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. The International Validation Protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood pressure measurements) making a total number of 33 participants (99 pairs of blood pressure measurements) on whom the final validation is performed. The same methodology recommended by the European Society of Hypertension protocol was applied for both studies. In each study and for each participant, four blood pressure measurements were taken simultaneously by two trained observers using mercury sphygmomanometers alternately with three measurements taken by the tested device. The difference between the blood pressure value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. The 99 pairs of blood pressure differences were classified into three categories (

  17. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.

    PubMed

    Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco

    2007-06-01

    There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never <35 within 5 mmHg and never <40 within 10 and 15 mmHg. The test device also passed phase 2 of the validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.

  18. 49 CFR 195.106 - Internal design pressure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Internal design pressure. 195.106 Section 195.106... PIPELINE Design Requirements § 195.106 Internal design pressure. (a) Internal design pressure for the pipe in a pipeline is determined in accordance with the following formula: P=(2St/D)×E×F P=Internal design...

  19. 49 CFR 195.106 - Internal design pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal design pressure. 195.106 Section 195.106... PIPELINE Design Requirements § 195.106 Internal design pressure. (a) Internal design pressure for the pipe in a pipeline is determined in accordance with the following formula: P=(2St/D)×E×F P=Internal design...

  20. High Pressure Electrolyzer System Evaluation

    NASA Technical Reports Server (NTRS)

    Prokopius, Kevin; Coloza, Anthony

    2010-01-01

    This report documents the continuing efforts to evaluate the operational state of a high pressure PEM based electrolyzer located at the NASA Glenn Research Center. This electrolyzer is a prototype system built by General Electric and refurbished by Hamilton Standard (now named Hamilton Sunstrand). It is capable of producing hydrogen and oxygen at an output pressure of 3000 psi. The electrolyzer has been in storage for a number of years. Evaluation and testing was performed to determine the state of the electrolyzer and provide an estimate of the cost for refurbishment. Pressure testing was performed using nitrogen gas through the oxygen ports to ascertain the status of the internal membranes and seals. It was determined that the integrity of the electrolyzer stack was good as there were no appreciable leaks in the membranes or seals within the stack. In addition to the integrity testing, an itemized list and part cost estimate was produced for the components of the electrolyzer system. An evaluation of the system s present state and an estimate of the cost to bring it back to operational status was also produced.

  1. Development and validity of a new model for assessing pressure redistribution properties of support surfaces.

    PubMed

    Matsuo, Junko; Sugama, Junko; Sanada, Hiromi; Okuwa, Mayumi; Nakatani, Toshio; Konya, Chizuko; Sakamoto, Jirou

    2011-05-01

    Pressure ulcers are a common problem, especially in older patients. In Japan, most institutionalized older people are malnourished and show extreme bony prominence (EBP). EBP is a significant factor in the development of pressure ulcers due to increased interface pressure concentrated at the skin surface over the EBP. The use of support surfaces is recommended for the prophylaxis of pressure ulcers. However, the present equivocal criteria for evaluating the pressure redistribution of support surfaces are inadequate. Since pressure redistribution is influenced by physique and posture, evaluations using human subjects are limited. For this reason, models that can substitute for humans are necessary. We developed a new EBP model based on the anthropometric measurements, including pelvic inclination, of 100 bedridden elderly people. A comparison between the pressure distribution charts of our model and bedridden elderly subjects demonstrated that maximum contact pressure values, buttock contact pressure values, and bone prominence rates corresponded closely. This indicates that the model provides a good approximation of the features of elderly people with EBP. We subsequently examined the validity of the model through quantitative assessment of pressure redistribution functions consisting of immersion, envelopment, and contact area change. The model was able to detect differences in the hardness of urethane foam, differences in the internal pressure of an air mattress, and sequential changes during the pressure switching mode. These results demonstrate the validity of our new buttock model in evaluating pressure redistribution for a variety of surfaces. Copyright © 2010 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  2. Full-scale hot cell test of an acoustic sensor dedicated to measurement of the internal gas pressure and composition of a LWR nuclear fuel rod

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrandis, J. Y.; Rosenkrantz, E.; Leveque, G.

    2011-07-01

    A full-scale hot cell test of the internal gas pressure and composition measurement by an acoustic sensor was carried on successfully between 2008 and 2010 on irradiated fuel rods in the LECA-STAR facility at Cadarache Centre. The acoustic sensor has been specially designed in order to provide a nondestructive technique to easily carry out the measurement of the internal gas pressure and gas composition of a LWR nuclear fuel rod. This sensor has been achieved in 2007 and is now covered by an international patent. The first positive result, concerning the device behaviour, is that the sensor-operating characteristics have notmore » been altered by a two-year exposure in the hot cell ambient. We performed the gas characterisation contained in irradiated fuel rods. The acoustic method accuracy is now {+-}5 bars on the pressure measurement result and {+-}0.3% on the evaluated gas composition. The results of the acoustic method were compared to puncture results. Another significant conclusion is that the efficiency of the acoustic method is not altered by the irradiation time, and possible modification of the cladding properties. These results make it possible to demonstrate the feasibility of the technique on irradiated fuel rods. The transducer and the associated methodology are now operational. (authors)« less

  3. Progressive Fracture of Fiber Composite Thin Shell Structures Under Internal Pressure and Axial Loads

    NASA Technical Reports Server (NTRS)

    Gotsis, Pascal K.; Chamis, Christos C.; Minnetyan, Levon

    1996-01-01

    Graphite/epoxy composite thin shell structures were simulated to investigate damage and fracture progression due to internal pressure and axial loading. Defective and defect-free structures (thin cylinders) were examined. The three different laminates examined had fiber orientations of (90/0/+/-0)(sub s), where 0 is 45, 60, and 75 deg. CODSTRAN, an integrated computer code that scales up constituent level properties to the structural level and accounts for all possible failure modes, was used to simulate composite degradation under loading. Damage initiation, growth, accumulation, and propagation to fracture were included in the simulation. Burst pressures for defective and defect-free shells were compared to evaluate damage tolerance. The results showed that damage initiation began with matrix failure whereas damage and/or fracture progression occurred as a result of additional matrix failure and fiber fracture. In both thin cylinder cases examined (defective and defect-free), the optimum layup configuration was (90/0/+/-60)(sub s) because it had the best damage tolerance with respect to the burst pressure.

  4. Getting evidence-based pressure ulcer prevention into practice: a multi-faceted unit-tailored intervention in a hospital setting.

    PubMed

    Sving, Eva; Högman, Marieann; Mamhidir, Anna-Greta; Gunningberg, Lena

    2016-10-01

    The aim of the study was to evaluate whether a multi-faceted, unit-tailored intervention using evidenced-based pressure ulcer prevention affects (i) the performance of pressure ulcer prevention, (ii) the prevalence of pressure ulcers and (iii) knowledge and attitudes concerning pressure ulcer prevention among registered and assistant nurses. A quasi-experimental, clustered pre- and post-test design was used. Five units at a hospital setting were included. The intervention was based on the PARIHS framework and included a multi-professional team, training and repeated quality measurements. An established methodology was used to evaluate the prevalence and prevention of pressure ulcers. Nurses' knowledge and attitudes were evaluated using a validated questionnaire. A total of 506 patients were included, of whom 105 patients had a risk to develop pressure ulcer. More patients were provided pressure ulcer prevention care (P = 0·001) and more prevention care was given to each patient (P = 0·021) after the intervention. Corresponding results were shown in the group of patients assessed as being at risk for developing pressure ulcers. Nurses' knowledge about pressure ulcer prevention increased (P < 0·001). Positive attitudes towards pressure ulcer prevention remained high between pre- and post-test surveys. This multi-faceted unit-tailored intervention affected pressure ulcer prevention. Facilitation and repeated quality measurement together with constructed feedback of results seemed to be the most important factor for pressure ulcer prevention. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. 75 FR 25303 - Advisory Committee on Reactor Safeguards (ACRS) Meeting of the ACRS Subcommittee on Regulatory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... (previously DG-1203) ``Containment Structural Integrity Evaluation for Internal Pressure Loadings Above Design... the time allotted to present oral statements can be obtained from the website cited above or by...

  6. Team science for science communication.

    PubMed

    Wong-Parodi, Gabrielle; Strauss, Benjamin H

    2014-09-16

    Natural scientists from Climate Central and social scientists from Carnegie Mellon University collaborated to develop science communications aimed at presenting personalized coastal flood risk information to the public. We encountered four main challenges: agreeing on goals; balancing complexity and simplicity; relying on data, not intuition; and negotiating external pressures. Each challenge demanded its own approach. We navigated agreement on goals through intensive internal communication early on in the project. We balanced complexity and simplicity through evaluation of communication materials for user understanding and scientific content. Early user test results that overturned some of our intuitions strengthened our commitment to testing communication elements whenever possible. Finally, we did our best to negotiate external pressures through regular internal communication and willingness to compromise.

  7. Probabilistic analysis of structures involving random stress-strain behavior

    NASA Technical Reports Server (NTRS)

    Millwater, H. R.; Thacker, B. H.; Harren, S. V.

    1991-01-01

    The present methodology for analysis of structures with random stress strain behavior characterizes the uniaxial stress-strain curve in terms of (1) elastic modulus, (2) engineering stress at initial yield, (3) initial plastic-hardening slope, (4) engineering stress at point of ultimate load, and (5) engineering strain at point of ultimate load. The methodology is incorporated into the Numerical Evaluation of Stochastic Structures Under Stress code for probabilistic structural analysis. The illustrative problem of a thick cylinder under internal pressure, where both the internal pressure and the stress-strain curve are random, is addressed by means of the code. The response value is the cumulative distribution function of the equivalent plastic strain at the inner radius.

  8. Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 6.0 ampere hour nickel-cadmium spacecraft cells with auxiliary electrodes for the atmospheric Explorer satellite C and D. [quality control testing

    NASA Technical Reports Server (NTRS)

    Harkness, J. D.

    1974-01-01

    The capacity of the cells ranged from 6.6 to 7.6 ampere hours during the three capacity tests. No voltage requirements or limits were exceeded during any portion of the test. All cells recovered to a voltage in excess of 1.193 volts during the 24-hour open-circuit portion of the internal short test. All the cells reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test. The average ampere/hours in and voltages at this pressure were 9.1 and 1.513, respectively. All cells exhibited pressure decay in the range of 1 to 5 psia during the last 30 minutes of the 1-hour open circuit stand. Average capacity out was 7.2 ampere/hours.

  9. Validation of the Andon KD595 for clinical use and self-measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye

    2016-04-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Andon KD595 for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using the standard mercury sphygmomanometer and the Andon KD595 device. Ninety-nine pairs of comparisons were obtained from 33 participants for analysis. The KD595 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10, and 15 mmHg was 72/99, 93/99, and 96/99, respectively, for SBP and 72/99, 96/99, and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. A total of 28 and 25 participants had at least two of the three device-observer differences within 5 mmHg (required≥24) for SBP and DBP, respectively. The number of participants without device-observer difference within 5 mmHg was two for SBP and two for DBP (required≤3). The Andon upper arm blood pressure monitor KD595 has passed the International Protocol requirements and it can be recommended for clinical use and self-measurement in adults.

  10. Summary of Activities for Health Monitoring of Composite Overwrapped Pressure Vessels

    NASA Technical Reports Server (NTRS)

    Russell, Rick

    2012-01-01

    This new start project (FY12-14) will design and demonstrate the ability of nondestructive evaluation sensors for the measurement of stresses on the inner diameter of a Composite Overwrapped Pressure Vessel overwrap. Results will be correlated with other nondestructive evaluation technologies such as Acoustic Emission. The project will build upon a proof of concept study performed at KSC which demonstrated the ability of Magnetic Stress Gages to measure stresses at internal overwraps and upon current acoustic emission research being performed at WSTF; The gages will be produced utilizing Maundering Winding Magnetometer and/or Maundering Winding Magnetometer-array eddy current technology. The proof-of-concept study demonstrated a correlation between the sensor response and pressure or strain. The study also demonstrated the ability of Maundering Winding Magnetometer technology to monitor the stresses in a Composite Overwrapped Pressure Vessel at different orientations and depths. The ultimate goal is to utilize this technology for the health monitoring of Composite Overwrapped Pressure Vessels for all future flight programs.

  11. Effectiveness of Sealed Double-Ring Infiltrometers{trademark} and effects of changes in atmospheric pressure on hydraulic conductivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMullin, S.R.

    The Savannah River Site is currently evaluating some 40 hazardous and radioactive-waste sites for remediation. Among the remedial alternatives considered is closure using a kaolin clay cap. The hydraulic conductivity suggested by the US Environmental Protection Agency is 1.0 {times} 10{sup {minus}7} cm/sec. One instrument to measure this value is the Sealed Double-Ring Infiltrometer{trademark} (SDRI). Six SDRI were recently installed on a kaolin test cap. Test results demonstrated uniform performance of these instruments. However, the test data showed as much as an order of magnitude of variation over time. This variation is attributed to both internal structural heterogeneity and variablemore » external boundary conditions. The internal heterogeneity is caused by construction variability within a specified range of moisture and density. The external influences considered are temperature and barometric pressure. Temperature was discharged as a source of heterogeneity because of a lack of correlation with test data and a negligible impact from the range of variability. However, a direct correlation was found between changes in barometric pressure and hydraulic conductivity. This correlation is most pronounced when pressure changes occur over a short period of time. Additionally, this correlation is related to a single soil layer. When the wetting front passes into a more porous foundation layer, the correlation with pressure changes disappears. Conclusions are that the SDRI performs adequately, with good repeatability of results. The duration of test is critical to assure a statistically valid data set. Data spikes resulting from pressure changes should be identified, and professional judgment used to determine the representative hydraulic conductivity. Further evaluation is recommended to determine the impact of pressure change on the actual hydraulic conductivity.« less

  12. Influence of everyday bolus consistencies in different body positions on high-resolution esophageal pressure topography (HREPT) parameters.

    PubMed

    Hasan, Y; Go, J; Hashmi, S M; Valestin, J; Schey, R

    2015-04-01

    The standard protocol for esophageal manometry involves placing the patient in the supine position with head turned to left (supine head left [SHL]) while evaluating liquid bolus swallows. Routinely, semisolid or solid boluses are not evaluated. Currently, the daily American diet includes up to 40% solid or semisolid texture. Thus far, the data on the effect of different bolus on high-resolution esophageal pressure topography (HREPT) parameters are scarce. This study aims to evaluate the effect of every day bolus consistencies in different body positions on HREPT variables. HREPT was performed on healthy volunteers with a modified protocol including liquid swallows in the SHL position followed by applesauce (semisolid), cracker (solid), and marshmallow (soft solid) in three different positions (SHL, sitting, and standing). A total of 38 healthy adult subjects (22 males and 16 females, median age = 27, and mean body mass index = 25) were evaluated. The resting upper esophageal sphincter pressure was significantly different while subjects swallowed crackers, applesauce, and marshmallows in most positions compared with liquid SHL (P < 0.05). The lower esophageal sphincter, contractile front velocity, and distal contractile integral pressures did not differ in all different consistencies compared with SHL. The integrated relaxation period was significantly higher with solid bolus compared with liquid bolus only in SHL position. The intrabolus pressure was significantly different with solid and soft solid boluses in all postures compared to liquid SHL. The American diet consistency affects upper esophageal sphincter pressure and partially integrated relaxation period and intrabolus pressure in various positions. Semisolid bolus swallows do not cause substantial pressure changes and are safe for evaluation and maintaining adequate caloric intake in patients with dysphagia who cannot tolerate solids. © 2014 International Society for Diseases of the Esophagus.

  13. Pressure ulcers: development and psychometric evaluation of the attitude towards pressure ulcer prevention instrument (APuP).

    PubMed

    Beeckman, D; Defloor, T; Demarré, L; Van Hecke, A; Vanderwee, K

    2010-11-01

    Pressure ulcers continue to be a significant problem in hospitals, nursing homes and community care settings. Pressure ulcer incidence is widely accepted as an indicator for the quality of care. Negative attitudes towards pressure ulcer prevention may result in suboptimal preventive care. A reliable and valid instrument to assess attitudes towards pressure ulcer prevention is lacking. Development and psychometric evaluation of the Attitude towards Pressure ulcer Prevention instrument (APuP). Prospective psychometric instrument validation study. A literature review was performed to design the instrument. Content validity was evaluated by nine European pressure ulcer experts and five experts in psychometric instrument validation in a double Delphi procedure. A convenience sample of 258 nurses and 291 nursing students from Belgium and The Netherlands participated in order to evaluate construct validity and stability reliability of the instrument. The data were collected between February and May 2008. A factor analysis indicated the construct of a 13 item instrument in a five factor solution: (1) attitude towards personal competency to prevent pressure ulcers (three items); (2) attitude towards the priority of pressure ulcer prevention (three items); (3) attitude towards the impact of pressure ulcers (three items); (4) attitude towards personal responsibility in pressure ulcer prevention (two items); and (5) attitude towards confidence in the effectiveness of prevention (two items). This five factor solution accounted for 61.4% of the variance in responses related to attitudes towards pressure ulcer prevention. All items demonstrated factor loadings over 0.60. The instrument produced similar results during stability testing [ICC=0.88 (95% CI=0.84-0.91, P<0.001)]. For the total instrument, the internal consistency (Cronbachs alpha) was 0.79. The APuP is a psychometrically sound instrument that can be used to effectively assess attitudes towards pressure ulcer prevention in patient care, education, and research. In further research, the association between attitude, knowledge and clinical performance should be explored. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. Equations for the determination of humidity from dewpoint and psychrometric data

    NASA Technical Reports Server (NTRS)

    Parish, O. O.; Putnam, T. W.

    1977-01-01

    A general expression based on the Claperon-Clausius differential equation that relates saturation vapor pressure, absolute temperature, and the latent heat of transformation was derived that expresses saturation vapor pressure as a function of absolute temperature. This expression was then used to derive general expressions for vapor pressure, absolute humidity, and relative humidity as functions of either dewpoint and ambient temperature or psychrometric parameters. Constants for all general expressions were then evaluated to give specific expressions in both the international system of units and U.S. customary units for temperatures above and below freezing.

  15. Noise transmission and reduction in turboprop aircraft

    NASA Astrophysics Data System (ADS)

    MacMartin, Douglas G.; Basso, Gordon L.; Leigh, Barry

    1994-09-01

    There is considerable interest in reducing the cabin noise environment in turboprop aircraft. Various approaches have been considered at deHaviland Inc., including passive tuned-vibration absorbers, speaker-based noise cancellation, and structural vibration control of the fuselage. These approaches will be discussed briefly. In addition to controlling the noise, a method of predicting the internal noise is required both to evaluate potential noise reduction approaches, and to validate analytical design models. Instead of costly flight tests, or carrying out a ground simulation of the propeller pressure field, a much simpler reciprocal technique can be used. A capacitive scanner is used to measure the fuselage vibration response on a deHaviland Dash-8 fuselage, due to an internal noise source. The approach is validated by comparing this reciprocal noise transmission measurement with the direct measurement. The fuselage noise transmission information is then combined with computer predictions of the propeller pressure field data to predict the internal noise at two points.

  16. Biomarkers Prognostic for Elevated Intracranial Pressure

    DTIC Science & Technology

    2016-03-01

    hematoma and active extravasation , for which she was taken emergently to interventional radiology for embolization of the bilateral internal iliac...approach to injuries was carried out. She was sent to IR for evaluation of her grade 3 liver laceration with active punctate extravasation and later

  17. The effect of ignition location on explosion venting of hydrogen-air mixtures

    NASA Astrophysics Data System (ADS)

    Cao, Y.; Guo, J.; Hu, K.; Xie, L.; Li, B.

    2017-07-01

    The effect of ignition location and vent burst pressure on the internal pressure-time history and external flame propagation was investigated for vented explosions of hydrogen-air mixtures in a small cylindrical vessel. A high-speed camera was used to record videos of the external flame while pressure transducers were used to record pressure-time histories. It was found that central ignition always leads to the maximum internal peak overpressure, and front ignition resulted in the lowest value of internal peak overpressure. The internal peak overpressures are increased corresponding to the increase in the vent burst pressure in the cases of central and rear ignition. Because of the effect of acoustic oscillations, the phenomenon of oscillations is observed in the internal pressure profile for the case of front ignition. The pressure oscillations for the cases of rear and central ignition are triggered by external explosions. The behavior of flames outside the chamber is significantly associated with the internal pressure of the chamber so that the velocity of the jet flame is closely related to the internal overpressure peak.

  18. Unmanned Evaluation of Mares Abyss 22 Navy Open Circuit Scuba Regulator for Cold Water Diving

    DTIC Science & Technology

    2011-05-05

    regulator is shown above the water. Note the blue mouthpiece adaptor, white oral static pressure pick-up ring , and gray routing block attached for...e.g., an inflation whip or a second-stage octopus ), submersible pressure gage, or gas-integrated computer were connected to the first stage. As...adaptor (shown in blue ) inward into the second-stage assembly, Figure 9 indicates typical 9 internal second-stage icing experienced during Phase

  19. Conformable pressure vessel for high pressure gas storage

    DOEpatents

    Simmons, Kevin L.; Johnson, Kenneth I.; Lavender, Curt A.; Newhouse, Norman L.; Yeggy, Brian C.

    2016-01-12

    A non-cylindrical pressure vessel storage tank is disclosed. The storage tank includes an internal structure. The internal structure is coupled to at least one wall of the storage tank. The internal structure shapes and internally supports the storage tank. The pressure vessel storage tank has a conformability of about 0.8 to about 1.0. The internal structure can be, but is not limited to, a Schwarz-P structure, an egg-crate shaped structure, or carbon fiber ligament structure.

  20. Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Takahashi, Hakuo; Yoshika, Masamichi; Yokoi, Toyohiko

    2013-01-01

    Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E). A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010. The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines. All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines.

  1. Static-stress analysis of dual-axis safety vessel

    NASA Astrophysics Data System (ADS)

    Bultman, D. H.

    1992-11-01

    An 8 ft diameter safety vessel, made of HSLA-100 steel, is evaluated to determine its ability to contain the quasi-static residual pressure from a high explosive (HE) blast. The safety vessel is designed for use with the Dual-Axis Radiographic Hydrotest (DARHT) facility being developed at Los Alamos National Laboratory. A smaller confinement vessel fits inside the safety vessel and contains the actual explosion, and the safety vessel functions as a second layer of containment in the unlikely case of a confinement vessel leak. The safety vessel is analyzed as a pressure vessel based on the ASME Boiler and Pressure Vessel Code, Section 8, Division 1, and the Welding Research Council Bulletin, WRC107. Combined stresses that result from internal pressure and external loads on nozzles are calculated and compared to the allowable stresses for HSLA-100 steel. Results confirm that the shell and nozzle components are adequately designed for a static pressure of 830 psi, plus the maximum expected external loads. Shell stresses at the 'shell to nozzle' interface, produced from external loads on the nozzles, were less than 700 psi. The maximum combined stress resulting from the internal pressure plus external loads was 17,384 psi, which is significantly less than the allowable stress of 42,375 psi for HSLA-100 steel.

  2. Static-stress analysis of dual-axis confinement vessel

    NASA Astrophysics Data System (ADS)

    Bultman, D. H.

    1992-11-01

    This study evaluates the static-pressure containment capability of a 6-ft-diameter, spherical vessel, made of HSLA-100 steel, to be used for high-explosive (HE) containment. The confinement vessel is designed for use with the Dual-Axis Radiographic Hydrotest Facility (DARHT) being developed at Los Alamos National Laboratory. Two sets of openings in the vessel are covered with x-ray transparent covers to allow radiographic imaging of an explosion as it occurs inside the vessel. The confinement vessel is analyzed as a pressure vessel based on the ASME Boiler and Pressure Vessel Code, Section 8, Division 1, and the Welding Research Council Bulletin, WRC-107. Combined stresses resulting from internal pressure and external loads on nozzles are calculated and compared with the allowable stresses for HSLA-100 steel. Results confirm that the shell and nozzles of the confinement vessel are adequately designed to safely contain the maximum residual pressure of 1675 psi that would result from an HE charge of 24.2 kg detonated in a vacuum. Shell stresses at the shell-to-nozzle interface, produced from external loads on the nozzles, were less than 400 psi. The maximum combined stress resulting from the internal pressure plus external loads was 16,070 psi, which is less than half the allowable stress of 42,375 psi for HSLA-100 steel.

  3. Validation of the Pangao PG-800B5 for clinical use and self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Chen, Wan; Zeng, Zhaolin; Li, Lizhi; Wan, Xiaofen; Wan, Yi

    2014-10-01

    This study aimed to validate the Pangao PG-800B5 upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. A total of 33 participants, 16 men and 17 women, were included in the device evaluation. The protocol requirements were followed precisely. The mean age of the participants was 56.4±21.0 years (range 22-84 years). The mean systolic blood pressure was 143.6±25.5 mmHg (range 98-188 mmHg), the mean diastolic blood pressure was 85.7±17.2 mmHg (range 49-125 mmHg), and the mean arm circumference was 26.1±2.2 cm (range 23-32 cm). On average, the device overestimated the systolic blood pressure by 0.9±4.2 mmHg and diastolic blood pressure by 0.7±4.5 mmHg. The device passed all requirements, fulfilling the standards of the protocol. Therefore, the Pangao PG-800B5 upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population.

  4. Analysis of an Aircraft Honeycomb Sandwich Panel with Circular Face Sheet/Core Disbond Subjected to Ground-Air Pressurization

    NASA Technical Reports Server (NTRS)

    Rinker, Martin; Krueger, Ronald; Ratcliffe, James

    2013-01-01

    The ground-air pressurization of lightweight honeycomb sandwich structures caused by alternating pressure differences between the enclosed air within the honeycomb core and the ambient environment is a well-known and controllable loading condition of aerospace structures. However, initial face sheet/core disbonds intensify the face sheet peeling effect of the internal pressure load significantly and can decrease the reliability of the sandwich structure drastically. Within this paper, a numerical parameter study was carried out to investigate the criticality of initial disbonds in honeycomb sandwich structures under ground-air pressurization. A fracture mechanics approach was used to evaluate the loading at the disbond front. In this case, the strain energy release rate was computed via the Virtual Crack Closure Technique. Special attention was paid to the pressure-deformation coupling which can decrease the pressure load within the disbonded sandwich section significantly when the structure is highly deformed.

  5. Anorectal motility abnormalities in children with encopresis and chronic constipation.

    PubMed

    Raghunath, Neeraj; Glassman, Mark S; Halata, Michael S; Berezin, Stuart H; Stewart, Julian M; Medow, Marvin S

    2011-02-01

    To evaluate the response to rectal distension in children with chronic constipation and children with chronic constipation and encopresis. We studied 27 children, aged 3 to 16 years, with chronic constipation; 12 had encopresis. Anorectal motility was measured with a solid state catheter. When the catheter was located in the internal sphincter, the balloon was inflated to 60 mL with air. There were no differences in age, sex distribution, and duration of constipation in the two groups. Comparing groups, anorectal manometry showed no differences in the resting sphincter pressure, recovery pressure, the lowest relaxation pressure, and percent relaxation. However, time to maximum relaxation, time to recovery to baseline pressure, and duration of relaxation were significantly higher in patients with constipation and encopresis, compared with patients who had constipation alone. There may be an imbalance in neuromuscular control of defecation in constipated patients with encopresis that results in incontinence as a consequence of the increased time to recovery and duration of relaxation of the internal anal sphincter. Copyright © 2011 Mosby, Inc. All rights reserved.

  6. Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Tian, Huiyong; Zeng, Sijian; Zhong, Xiaoyan; Gong, Wei; Liu, Wenjun

    2015-10-01

    Transtek blood pressure monitor TMB-1491 is an automatic upper arm device designed for self/home measurement in adult populations. This study aimed to evaluate its accuracy according to the European Society of Hypertension International Protocol revision 2010. The protocol requirements were followed precisely with the recruitment of 33 adult individuals on whom same-left-arm sequential systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements were obtained in this study (three pairs for each of the 33 participants). The device produced 74, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 85, 97, and 99 for DBP, respectively. The mean±SD device-observer difference was -0.6±4.4 mmHg for SBP and -0.6±3.4 mmHg for DBP. The number of participants with two or three device-observer difference within 5 mmHg was 24 for SBP and 29 for DBP. In addition, none of the participants had a device-observer difference within 5 mmHg for SBP, and three of the participants had the same for DBP. Transtek TMB-1491 has passed all phases of European Society of Hypertension International Protocol revision 2010 and can be recommended for self/home measurement in adult populations.

  7. Relationship Among Anal Sphincter Injury, Patulous Anal Canal, and Anal Pressures in Patients with Anorectal Disorders

    PubMed Central

    Prichard, David; Harvey, Doris M.; Fletcher, Joel G.; Zinsmeister, Alan R.; Bharucha, Adil E.

    2015-01-01

    Background & Aims The anal sphincters and puborectalis are routinely imaged with an endoanal magnetic resonance imaging (MRI) coil, which does not assess co-aptation of the anal canal at rest. Using a MRI torso coil, we identified a patulous anal canal in some patients with anorectal disorders. We aimed to evaluate the relationship between anal sphincter and puborectalis injury, a patulous anal canal, and anal pressures. Methods We performed a retrospective analysis of data from 119 patients who underwent MRI and manometry analysis of anal anatomy and pressures, respectively, from February 2011 through March 2013 at the Mayo Clinic. Anal pressures were determined by high-resolution manometry, anal sphincter and puborectalis injury was determined by endoanal MRI, and anal canal integrity was determined by torso MRI. Associations between manometric and anatomical parameters were evaluated with univariate and multivariate analyses. Results Fecal incontinence (55 patients, 46%) and constipation (36 patients. 30%) were the main indications for testing; 49 patients (41%) had a patulous anal canal, which was associated with injury to more than 1 muscle (all P≤.001) and internal sphincter (P<.01), but not puborectalis (P=.09) or external sphincter (P=.06) injury. Internal (P<.01) and external sphincter injury (P=.02) and a patulous canal (P<.001), but not puborectalis injury, predicted anal resting pressure. A patulous anal canal was the only significant predictor (P<.01) of the anal squeeze pressure increment. Conclusions Patients with anorectal disorders commonly have a patulous anal canal, associated with more severe anal injury, anal resting pressure, and squeeze pressure increment. It is therefore important to identify patulous anal canal because it appears to be a marker of not only anal sphincter injury but disturbances beyond sphincter injury, such as damage to the anal cushions or anal denervation. PMID:25869638

  8. High pressure extraction of phenolic compounds from citrus peels†

    NASA Astrophysics Data System (ADS)

    Casquete, R.; Castro, S. M.; Villalobos, M. C.; Serradilla, M. J.; Queirós, R. P.; Saraiva, J. A.; Córdoba, M. G.; Teixeira, P.

    2014-10-01

    This study evaluated the effect of high pressure processing on the recovery of high added value compounds from citrus peels. Overall, the total phenolic content in orange peel was significantly (P < .05) higher than that in lemon peel, except when pressure treated at 500 MPa. However, lemon peel demonstrated more antioxidant activity than orange peel. Pressure-treated samples (300 MPa, 10 min; 500 MPa, 3 min) demonstrated higher phenolic content and antioxidant activity comparatively to the control samples. For more severe treatments (500 MPa, 10 min), the phenolic content and antioxidant activity decreased in both lemon and orange peels. This paper was presented at the 8th International Conference on High Pressure Bioscience & Biotechnology (HPBB 2014), in Nantes (France), 15-18 July 2014.

  9. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol.

    PubMed

    Altunkan, Sekip; Ilman, Nevzat; Altunkan, Erkan

    2007-04-01

    A variety of automatic blood measurement devices with diverse features have been introduced to the medical markets recently. Among these devices, models that measure at the wrist have become increasingly popular in self measurements. The objective of this study was to evaluate the accuracy of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure devices against the mercury sphygmomanometer in adults according to the International Protocol criteria. Fifty-four patients over 30 years of age were studied and classified based on the International Protocol range. Blood pressure measurements at the wrist with the Samsung SBM-100A and Microlife BP 3BU1-5 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 participants with randomly distributed arm circumferences were selected for both of the validation studies. During each validation study, 99 measurements were obtained for comparison from 33 participants. The first phase was performed on 15 participants and if the device passed this phase, 18 more participants were selected. Mean discrepancies and standard deviations of the device-sphygmomanometer were 0.9+/-9.2 and -2.7+/-9.3 mmHg for systolic blood pressure and -1.4+/-8.0 mmHg and 1.4+/-5.7 for diastolic blood pressure in the Samsung and Microlife study groups, respectively. The Samsung SBM-100A passed Phase 1 in 15 participants. Despite the fact that Microlife BP 3BU1-5 passed Phase 1 for diastolic pressure, it failed according to the systolic pressure criteria. Eighteen patients were added and Phase 2 was continued, in which Samsung SBM-100A failed to meet the criteria of Phases 2.1 and 2.2 for adults in systolic and diastolic blood pressure. It was found that the Microlife BP 3BU1-5 does not meet the criteria of either of Phases 2.1 and 2.2 for systolic blood pressure and Phase 2.2 for diastolic blood pressure. In this study, Samsung SBM-100A and Microlife blood pressure 3BU1-5 wrist blood pressure monitoring devices were found to be incompetent to meet the criteria of the International Protocol and it has not been possible to suggest any one of them for clinical use in adults.

  10. Validity and reliability of the Turkish version of the pressure ulcer prevention knowledge assessment instrument.

    PubMed

    Tulek, Zeliha; Polat, Cansu; Ozkan, Ilknur; Theofanidis, Dimitris; Togrol, Rifat Erdem

    2016-11-01

    Sound knowledge of pressure ulcers is important to enable good prevention. There are limited instruments assessing pressure ulcer knowledge. The Pressure Ulcer Prevention Knowledge Assessment Instrument is among the scales of which psychometric properties have been studied rigorously and reflects the latest evidence. This study aimed to evaluate the validity and reliability of the Turkish version of the Pressure Ulcer Prevention Knowledge Assessment Instrument (PUPKAI-T), an instrument that assesses knowledge of pressure ulcer prevention by using multiple-choice questions. Linguistic validity was verified through front-to-back translation. Psychometric properties of the instrument were studied on a sample of 150 nurses working in a tertiary hospital in Istanbul, Turkey. The content validity index of the translated instrument was 0.94, intra-class correlation coefficients were between 0.37 and 0.80, item difficulty indices were between 0.21 and 0.88, discrimination indices were 0.20-0.78, and the Kuder Richardson for the internal consistency was 0.803. The PUPKAI-T was found to be a valid and reliable tool to evaluate nurses' knowledge on pressure ulcer prevention. The PUPKAI-T may be a useful tool for determining educational needs of nurses on pressure ulcer prevention. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  11. Relationships amongst body dissatisfaction, internalisation of the media body ideal and perceived pressure from media in adolescent girls and boys.

    PubMed

    Knauss, Christine; Paxton, Susan J; Alsaker, Françoise D

    2007-12-01

    Sociocultural factors that underpin gender differences in body dissatisfaction have not frequently been explored. We examined the relative contribution of internalization of media body ideals and perceived pressure to achieve this ideal in explaining body dissatisfaction in adolescent boys and girls. A sample of 819 boys and 791 girls completed measures of internalization of body ideals, perceived pressure, body mass index (BMI) and body dissatisfaction. As expected, girls showed higher body dissatisfaction, internalization and pressure than boys. Internalization, pressure and BMI contributed to the prediction of body dissatisfaction in boys and in girls although these variables explained less variance in body dissatisfaction in boys. In addition, for girls the strongest predictor of body dissatisfaction was internalization, whilst for boys the strongest predictor was pressure. Differences in extent of internalization and pressure may contribute to higher body dissatisfaction in girls than boys. These sociocultural factors may affect girls and boys differently.

  12. Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere hour nickel cadmium spacecraft cells for the tracking data relay satellite system

    NASA Technical Reports Server (NTRS)

    Hall, S. W.

    1980-01-01

    Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.

  13. Demonstration of Hazardous Hypervelocity Test Capability

    NASA Technical Reports Server (NTRS)

    Rodriquez, Karen M.

    1991-01-01

    NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) participated in a joint test program with NASA JSC Hypervelocity Impact Research Laboratory (HIRL) to determine if JSC was capable of performing hypervelocity impact tests on hazardous targets. Seven pressurized vessels were evaluated under hypervelocity impact conditions. The vessels were tested with various combinations of liquids and gasses at various pressures. Results from the evaluation showed that vessels containing 100-percent pressurized gas sustained more severe damage and had a higher potential for damaging nearby equipment, than vessels containing 75-percent liquid, 25-percent inert pressurized gas. Two water-filled test vessels, one of which was placed behind an aluminum shield, failed by bulging and splitting open at the impact point; pressure was relieved without the vessel fragmenting or sustaining internal damage. An additional water-filled test vessel, placed a greater distance behind an aluminum shield, sustained damage that resembled a shotgun blast, but did not bulge or split open; again, pressure was relieved without the vessel fragmenting. Two test vessels containing volatile liquids (nitro methane and hydrazine) also failed by bulging and splitting open; neither liquid detonated under hypervelocity test conditions. A test vessel containing nitrogen gas failed by relieving pressure through a circular entry hole; multiple small penetrations opposite the point of entry provided high velocity target debris to surrounding objects. A high-pressure oxygen test vessel fragmented upon impact; the ensuing fire and high velocity fragments caused secondary damage to surrounding objects. The results from the evaluation of the pressurized vessels indicated that JSC is capable of performing hypervelocity impact tests on hazardous targets.

  14. Insulation systems for liquid methane fuel tanks for supersonic cruise aircraft

    NASA Technical Reports Server (NTRS)

    Brady, H. F.; Delduca, D.

    1972-01-01

    Two insulation systems for tanks containing liquid methane in supersonic cruise-type aircraft were designed and tested after an extensive materials investigation. One system is an external insulation and the other is an internal wet-type insulation system. Tank volume was maximized by making the tank shape approach a rectangular parallelopiped. One tank was designed to use the external insulation and the other tank to use the internal insulation. Performance of the external insulation system was evaluated on a full-scale tank under the temperature environment of -320 F to 700 F and ambient pressures of ground-level atmospheric to 1 psia. Problems with installing the internal insulation on the test tank prevented full-scale evaluation of performance; however, small-scale testing verified thermal conductivity, temperature capability, and installed density.

  15. Parametric study of orthopedic insole of valgus foot on partial foot amputation.

    PubMed

    Guo, Jun-Chao; Wang, Li-Zhen; Chen, Wei; Du, Cheng-Fei; Mo, Zhong-Jun; Fan, Yu-Bo

    2016-01-01

    Orthopedic insole was important for partial foot amputation (PFA) to achieve foot balance and avoid foot deformity. The inapposite insole orthosis was thought to be one of the risk factors of reamputation for foot valgus patient, but biomechanical effects of internal tissues on valgus foot had not been clearly addressed. In this study, plantar pressure on heel and metatarsal regions of PFA was measured using F-Scan. The three-dimensional finite element (FE) model of partial foot evaluated different medial wedge angles (MWAs) (0.0°-10.0°) of orthopedic insole on valgus foot. The effect of orthopedic insole on the internal bone stress, the medial ligament tension of ankle, plantar fascia tension, and plantar pressure was investigated. Plantar pressure on medial heel region was about 2.5 times higher than that of lateral region based on the F-Scan measurements. FE-predicted results showed that the tension of medial ankle ligaments was the lowest, and the plantar pressure was redistributed around the heel, the first metatarsal, and the lateral longitudinal arch regions when MWA of orthopedic insole ranged from 7.5° to 8.0°. The plantar fascias maintained about 3.5% of the total load bearing on foot. However, the internal stresses from foot bones increased. The simulation in this study would provide the suggestion of guiding optimal design of orthopedic insole and therapeutic planning to pedorthist.

  16. Biomechanical evaluation of heel elevation on load transfer — experimental measurement and finite element analysis

    NASA Astrophysics Data System (ADS)

    Luximon, Yan; Luximon, Ameersing; Yu, Jia; Zhang, Ming

    2012-02-01

    In spite of ill-effects of high heel shoes, they are widely used for women. Hence, it is essential to understand the load transfer biomechanics in order to design better fit and comfortable shoes. In this study, both experimental measurement and finite element analysis were used to evaluate the biomechanical effects of heel height on foot load transfer. A controlled experiment was conducted using custom-designed platforms. Under different weight-bearing conditions, peak plantar pressure, contact area and center of pressure were analyzed. A three-dimensional finite element foot model was used to simulate the high-heel support and to predict the internal stress distributions and deformations for different heel heights. Results from both experiment and model indicated that heel elevations had significant effects on all variables. When heel elevation increased, the center of pressure shifted from the midfoot region to the forefoot region, the contact area was reduced by 26% from 0 to 10.2 cm heel and the internal stress of foot bones increased. Prediction results also showed that the strain and total tension force of plantar fascia was minimum at 5.1 cm heel condition. This study helps to better understand the biomechanical behavior of foot, and to provide better suggestions for design parameters of high heeled shoes.

  17. Time-dependent response of filamentary composite spherical pressure vessels

    NASA Technical Reports Server (NTRS)

    Dozier, J. D.

    1983-01-01

    A filamentary composite spherical pressure vessel is modeled as a pseudoisotropic (or transversely isotropic) composite shell, with the effects of the liner and fill tubes omitted. Equations of elasticity, macromechanical and micromechanical formulations, and laminate properties are derived for the application of an internally pressured spherical composite vessel. Viscoelastic properties for the composite matrix are used to characterize time-dependent behavior. Using the maximum strain theory of failure, burst pressure and critical strain equations are formulated, solved in the Laplace domain with an associated elastic solution, and inverted back into the time domain using the method of collocation. Viscoelastic properties of HBFR-55 resin are experimentally determined and a Kevlar/HBFR-55 system is evaluated with a FORTRAN program. The computed reduction in burst pressure with respect to time indicates that the analysis employed may be used to predict the time-dependent response of a filamentary composite spherical pressure vessel.

  18. Flammability and sensitivity of materials in oxygen-enriched atmospheres; Proceedings of the Fourth International Symposium, Las Cruces, NM, Apr. 11-13, 1989. Volume 4

    NASA Technical Reports Server (NTRS)

    Stoltzfus, Joel M. (Editor); Benz, Frank J. (Editor); Stradling, Jack S. (Editor)

    1989-01-01

    The present volume discusses the ignition of nonmetallic materials by the impact of high-pressure oxygen, the promoted combustion of nine structural metals in high-pressure gaseous oxygen, the oxygen sensitivity/compatibility ranking of several materials by different test methods, the ignition behavior of silicon greases in oxygen atmospheres, fire spread rates along cylindrical metal rods in high-pressure oxygen, and the design of an ignition-resistant, high pressure/temperature oxygen valve. Also discussed are the promoted ignition of oxygen regulators, the ignition of PTFE-lined flexible hoses by rapid pressurization with oxygen, evolving nonswelling elastomers for high-pressure oxygen environments, the evaluation of systems for oxygen service through the use of the quantitative fault-tree analysis, and oxygen-enriched fires during surgery of the head and neck.

  19. 40-in. OMS Kevlar(Registered Trademark) COPV S/N 007 Stress Rupture Test NDE

    NASA Technical Reports Server (NTRS)

    Saulsberry, Regor; Greene, Nate; Forth, Scott; Leifeste, Mark; Gallus, Tim; Yoder, Tommy; Keddy, Chris; Mandaras, Eric; Wincheski, Buzz; Williams, Philip; hide

    2010-01-01

    The presentation examines pretest nondestructive evaluation (NDE), including external/internal visual inspection, raman spectroscopy, laser shearography, and laser profilometry; real-time NDE including eddy current, acoustic emission (AE), and real-time portable raman spectroscopy; and AE application to carbon/epoxy composite overwrapped pressure vessels.

  20. Instrument for evaluation of sedentary lifestyle in patients with high blood pressure.

    PubMed

    Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; de Araujo, Thelma Leite; Guedes, Nirla Gomes; Martins, Larissa Castelo Guedes; Teixeira, Iane Ximenes

    2015-01-01

    this article describes the diagnostic accuracy of the International Physical Activity Questionnaire to identify the nursing diagnosis of sedentary lifestyle. a diagnostic accuracy study was developed with 240 individuals with established high blood pressure. The analysis of diagnostic accuracy was based on measures of sensitivity, specificity, predictive values, likelihood ratios, efficiency, diagnostic odds ratio, Youden index, and area under the receiver-operating characteristic curve. statistical differences between genders were observed for activities of moderate intensity and for total physical activity. Age was negatively correlated with activities of moderate intensity and total physical activity. the analysis of area under the receiver-operating characteristic curve for moderate intensity activities, walking, and total physical activity showed that the International Physical Activity Questionnaire present moderate capacity to correctly classify individuals with and without sedentary lifestyle.

  1. Central Heat Plant Modernization: FY98 Update and Recommendations.

    DTIC Science & Technology

    1999-12-01

    Boiler and Pressure Vessel Code suggests an inspection frequency of 12 months for...28 April 1997). ASME International, Boiler and Pressure Vessel Code (ASME International, New York, NY, 1995). Bloomquist, R.G., J.D. Nimmons, and K...Services (HQDA, 28 April 1997). ASME International, Boiler and Pressure Vessel Code (ASME International, New York, NY, 1995). Bloomquist, R.G.,

  2. Hyperion 5113/A Infrasound Sensor Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Bion John

    2015-09-01

    Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/A manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, and dynamic range. The 5113/A infrasound sensor is a new revision of the 5000 series intended to meet the infrasound application requirements for use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

  3. Magnetic Resonance Imaging With Cochlear Implant Magnet in Place: Safety and Imaging Quality.

    PubMed

    Carlson, Matthew L; Neff, Brian A; Link, Michael J; Lane, John I; Watson, Robert E; McGee, Kiaran P; Bernstein, Matt A; Driscoll, Colin L W

    2015-07-01

    To evaluate the safety and image quality of 1.5-T MRI in patients with cochlear implants and retained internal magnets. Retrospective case series from 2012 to 2014. Single tertiary academic referral center. All cochlear implant recipients undergoing 1.5-T MRI without internal magnet removal. MRI after tight headwrap application. Patient tolerance, complications, and characteristics of imaging artifact. Nineteen ears underwent a total of 34 MRI scans. Two patients did not tolerate imaging with the headwrap in place and required magnet removal before rescanning. One subject experienced two separate episodes of polarity reversal in the same device from physical realignment (i.e., flipping) of the internal magnet requiring surgical repositioning. Three patients were discovered to have canting of the internal magnet after imaging. In all three cases, the magnet could be reseated by applying gentle firm pressure to the scalp until the magnet "popped" back into place. These patients continue to use their device without difficulty and have not required surgical replacement. In patients receiving head MRI, the ipsilateral internal auditory canal and cerebellopontine angle could be visualized without difficulty in 94% of cases. There were no episodes of cochlear implant device failure or soft tissue complications. Under controlled conditions, 1.5-T MRI can be successfully performed in most patients without the need for cochlear implant magnet removal. In nearly all cases, imaging artifact does not impede evaluation of the ipsilateral skull base. Patients should be counseled regarding the risk of internal magnet movement that may occur in up to 15% of cases, even with tight headwrap application. If internal magnet polarity reversal occurs, a trial of reversing the external magnet can be considered. If canting or mild displacement of the internal magnet occurs, an attempt at reseating can be made by applying gentle firm pressure to the scalp over the internal magnet. If conservative measures fail, the magnet should be surgically repositioned to minimize interruption of device use and to prevent scalp complications.

  4. Influence of inward pressure of the transducer on lateral abdominal muscle thickness during ultrasound imaging.

    PubMed

    Ishida, Hiroshi; Watanabe, Sususmu

    2012-09-01

    Controlled laboratory study, technical note. The purpose of this study was to quantify changes in the thickness of the transversus abdominis, internal oblique, and external oblique muscles induced by different inward pressures of the transducer during ultrasound imaging (USI). USI of the lateral abdominal muscles is increasingly used in managing musculoskeletal dysfunction. However, to the best of our knowledge, no study has evaluated the influence of different inward pressures of the transducer on the lateral abdominal muscle thickness during USI. Thirty healthy male volunteers participated in this study. The thickness of the transversus abdominis, internal oblique, and external oblique muscles was measured with USI by the same rater in 4 conditions of inward pressures of 0.5, 1.0, 2.0, and 4.0 N. Intraclass correlation coefficients (ICC1,1), with 95% confidence intervals, were calculated, and a repeated-measures analysis of variance was used to assess the influence of inward pressure on the thickness of the lateral abdominal muscles. The thickness of the transversus abdominis, internal oblique, and external oblique muscles was significantly different among the 4 conditions (P<.038). The mean difference between the 0.5-N and 4.0-N conditions was greater than the minimal detectable change of the 0.5-N condition in the lateral abdominal muscles. The difference in magnitude produced by the forces under different conditions was meaningful. When using a technique that involves a handheld transducer, the examiner should attempt to maintain consistent inward pressure of the transducer during USI to quantify the thickness of lateral abdominal muscles. J Orthop Sports Phys Ther 2012;42(9):815-818, Epub 19 April 2012. doi:10.2519/jospt.2012.4064.

  5. Product layer development during sulfation and sulfidation of uncalcined limestone particles at elevated pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zevenhoven, C.A.P.; Yrjas, K.P.; Hupa, M.M.

    1998-07-01

    Fluidized bed combustion or gasification allows for in-bed sulfur capture with a calcium-based sorbent such as limestone or dolomite. Sorbent particle size, porosity, internal surface, and their variation during conversion have great influence on the conversion of the sorbent. The uptake of SO{sub 2} and H{sub 2}S by five physically different limestones is discussed, for typical pressurized fluidized bed combustor or gasifier conditions: 850/950 C, 15/20 bar. Tests were done in a pressurized thermogravimetric apparatus (P-TGA), the size of the limestone particles was 250--300 {micro}m. It is stressed that the limestones remain uncalcined. A changing internal structure (CIS) model ismore » presented in which reaction kinetics and product layer diffusion are related to the intraparticle surface of reaction, instead of the outer particle surface as in unreacted shrinking core (USC)-type models. The random pore model was used for describing the changing internal pore and reaction surfaces. Rate parameters were extracted for all five limestones using the CIS model and a USC model with variable effective diffusivity. Differences in the sulfur capture performance of the limestones were evaluated. Plots of the CaSO{sub 4} or CaS product layer thickness as a function of conversion are given, and the relative importance of limestone porosity and internal surface is discussed.« less

  6. A study of the eigenvectors of the vibrational modes in crystalline cytidine via high-pressure Raman spectroscopy.

    PubMed

    Lee, Scott A; Pinnick, David A; Anderson, A

    2015-01-01

    Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the vibrational modes of crystalline cytidine at 295 K and high pressures by evaluating the logarithmic derivative of the vibrational frequency ω with respect to pressure P: [Formula: see text]. Crystalline samples of molecular materials have strong intramolecular bonds and weak intermolecular bonds. This hierarchy of bonding strengths causes the vibrational optical modes localized within a molecular unit ("internal" modes) to be relatively high in frequency while the modes in which the molecular units vibrate against each other ("external" modes) have relatively low frequencies. The value of the logarithmic derivative is a useful diagnostic probe of the nature of the eigenvector of the vibrational modes because stretching modes (which are predominantly internal to the molecule) have low logarithmic derivatives while external modes have higher logarithmic derivatives. In crystalline cytidine, the modes at 85.8, 101.4, and 110.6 cm(-1) are external in which the molecules of the unit cell vibrate against each other in either translational or librational motions (or some linear combination thereof). All of the modes above 320 cm(-1) are predominantly internal stretching modes. The remaining modes below 320 cm(-1) include external modes and internal modes, mostly involving either torsional or bending motions of groups of atoms within a molecule.

  7. Migration and geographic variations in blood pressure in Britain.

    PubMed Central

    Elford, J; Phillips, A; Thomson, A G; Shaper, A G

    1990-01-01

    OBJECTIVE--To evaluate the relative contributions of factors acting at different stages in life to regional differences in adult blood pressure. DESIGN--Prospective cohort study (British regional heart study). SETTING--One general practice in each of 24 towns in Britain. SUBJECTS--7735 Men aged 40-59 years when screened in 1978-80 whose geographic zone of birth and zone of examination were classified as south of England, midlands and Wales, north of England, and Scotland. Non-migrants (n = 3144) were born in the town where they were examined; internal migrants (n = 4147) were born in Great Britain but not in the town where they were examined; and international migrants (n = 422) were born outside Great Britain. MAIN OUTCOME MEASURES--Systolic and diastolic blood pressures and height. RESULTS--Regardless of where they were born, men living in the south of England had lower mean blood pressures than men living in Scotland (142.5/80.1 v 148.1/85.2 mm Hg). The effects of the place of birth and place of examination on adult blood pressure were examined in a multiple regression model. For internal migrants the modelled increase in mean systolic blood pressure across adjacent zones of examination was 2.1 mm Hg (95% confidence interval 1.3 to 2.9); for adjacent zones of birth the corresponding increase was 0.1 mm Hg (-0.7 to 0.7). The place of examination seemed to be a far more important determinant of mean adult blood pressure than the place of birth. Height is an accepted marker of genetic and early life influences. Regional differences in height were therefore analysed to test whether the multiple regression model could correctly distinguish between the influence of place of birth and place of examination. As expected, men born in Scotland were shorter on average than men born in the south of England irrespective of where they lived in Britain (172.6 cm v 175.1 cm for internal migrants). CONCLUSION--Regional variations in blood pressure were strongly influenced by where the men had lived for most of their adult lives rather than by where they were born and brought up. Among middle aged men, factors acting in adult life seemed to be more important determinants of regional differences in blood pressure than those acting early in life such as genetic inheritance, intrauterine environment, and childhood experience. PMID:2106957

  8. Minimally invasive sinus augmentation using ultrasonic piezoelectric vibration and hydraulic pressure: a multicenter retrospective study.

    PubMed

    Kim, Ji-Min; Sohn, Dong-Seok; Heo, Jeong-Uk; Park, Jun-Sub; Jung, Heui-Seung; Moon, Jee-Won; Lee, Ju-Hyoung; Park, In-Sook

    2012-12-01

    The purpose of this study was to evaluate the success rate of implants and vertical bone gain of edentulous posterior maxilla using ultrasonic piezoelectric vibration and hydraulic pressure, namely the hydrodynamic piezoelectric internal sinus elevation (HPISE) technique through a crestal approach. A total of 250 maxillary sinuses were augmented using HPISE and 353 implants (averaging 11.8 mm in length and 4.5 mm in diameter), with 12 different systems, were placed simultaneously with or without additional bone grafting. Plain radiograms and cone beam computed tomograms were taken in all patients to evaluate sinus augmentation. Membrane perforation was recorded at 10 of the 353 implant sites. The perforation rate was 2.83%. The total success rate of implantation was 97.2% after an average of 69.3 weeks of loading. The crestally approached sinus augmentation using ultrasonic piezoelectric vibration and hydraulic pressure is an additional method of maxillary sinus augmentation.

  9. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    PubMed

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  10. The evaluation model of the enterprise energy efficiency based on DPSR.

    PubMed

    Wei, Jin-Yu; Zhao, Xiao-Yu; Sun, Xue-Shan

    2017-05-08

    The reasonable evaluation of the enterprise energy efficiency is an important work in order to reduce the energy consumption. In this paper, an effective energy efficiency evaluation index system is proposed based on DPSR (Driving forces-Pressure-State-Response) with the consideration of the actual situation of enterprises. This index system which covers multi-dimensional indexes of the enterprise energy efficiency can reveal the complete causal chain which includes the "driver forces" and "pressure" of the enterprise energy efficiency "state" caused by the internal and external environment, and the ultimate enterprise energy-saving "response" measures. Furthermore, the ANP (Analytic Network Process) and cloud model are used to calculate the weight of each index and evaluate the energy efficiency level. The analysis of BL Company verifies the feasibility of this index system and also provides an effective way to improve the energy efficiency at last.

  11. Hypertensive crisis. Clinical presentation, comorbidities, and target organ involvement.

    PubMed

    Al-Bannay, Rashed; Husain, Aysha A

    2010-08-01

    To evaluate the clinical presentation and comorbidities of hypertensive crisis in our own population. In this cohort based study, we investigate the clinical presentation and comorbidities of hypertensive crisis by evaluating the data collected between January and April 2009. We included 154 patients admitted with systolic and diastolic blood pressure of >179 mm Hg and >119 mm Hg (based on the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure criteria) in the Department of Internal Medicine, Salmaniya Medical Complex, Kingdom of Bahrain. In the study population, 64.3% had hypertensive urgency (blood pressure elevation without end organ damage) and 35.7% had hypertensive emergency (blood pressure elevation with end organ damage). The mean age group was 45-65 years (56% of the study population) and more men were affected than women (100:54). Shortness of breath and neurological deficits had a strong statistical association with hypertensive emergency, and headache and blurring of vision had the same tendency toward hypertensive urgency. Diabetes mellitus was an independent risk factor for hypertensive crisis. Most of the studied patients were known hypertensive. Diabetes mellitus is powerful predictor for hypertensive crisis. Dyspnea and neurological deficits have significant statistical correlation with hypertensive emergencies.

  12. Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

    PubMed

    Bhaskaran, Eswaran; Azhagarasan, N S; Miglani, Saket; Ilango, T; Krishna, G Phani; Gajapathi, B

    2013-09-01

    Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.

  13. Perceived social pressures and the internalization of the mesomorphic ideal: The role of drive for muscularity and autonomy in physically active men.

    PubMed

    Edwards, Christian; Tod, David; Molnar, Gyozo; Markland, David

    2016-03-01

    We examined if there were both direct and indirect relationships (via the drive for muscularity) between the perceived pressure to be muscular and internalization of the mesomorphic ideal, and if autonomy moderates these relationships in physically active men. A sample of 330 men, who were undergraduate students studying sport, completed the Behavioral Regulation in Exercise Questionnaire-2, the Mesomorphic Ideal Internalization subscale of the revised male version Sociocultural Attitudes Toward Appearance Questionnaire, the Perceived Sociocultural Pressure Scale-Modified, and the Drive for Muscularity Scale Attitudes subscale. Perceived pressure predicted internalization directly, and indirectly through the drive for muscularity. The direct relationship between pressure and internalization was weaker under higher levels of autonomy. The indirect path, via drive for muscularity, was stronger under higher levels of autonomy. These results provide insights into why men vary in the degree to which they internalize pressure to develop a mesomorphic ideal, supporting further examination of autonomy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    PubMed

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  15. Validation of the Omron HEM-7201 upper arm blood pressure monitor, for self-measurement in a high-altitude environment, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Cho, K; Tian, M; Lan, Y; Zhao, X; Yan, L L

    2013-08-01

    Few studies have been conducted on blood pressure monitors and their use at high altitude. This study is the first to evaluate the accuracy of an automatic blood pressure monitor in a high-altitude environment following a standard validation protocol. The Omron HEM-7201 upper arm blood pressure monitor was tested for accuracy in Lhasa, Tibet, China (3650 m above sea level) according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2). Thirty-three participants received 9-10 sequential blood pressure measurements alternating between a mercury sphygmomanometer and the device. The mean device-observer measurement difference was 1.0±5.9 mm Hg for systolic blood pressure (SBP) and -3.1±4.6 mm Hg for diastolic blood pressure (DBP). Of the 99 measurement pairs analyzed, 72, 90 and 97 device readings were within 5, 10 and 15 mm Hg, respectively, of the observer measurements for SBP, and 68, 92 and 99 readings for DBP. The number of participants with at least two out of three measurements within 5 mm Hg was 27 for SBP and 25 for DBP. Three participants had no measurements within 5 mm Hg for either SBP or DBP. As a result, the Omron HEM-7201 passes the ESH-IP2 validation criteria and can therefore be recommended for use in adults in this setting.

  16. Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Chen, Can; Shang, Fujun; Wang, Jiepin; Chen, Jianghong; Ji, Na; Wan, Yi

    2012-12-01

    This study aimed to evaluate the performance of the iHealth BP3 upper-arm blood pressure monitor, which is designed for clinic use and self-measurement of blood pressure using Apple touch devices as an interface. The European Society of Hypertension International Protocol (ESH-IP) revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. Ninty-nine couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The 33 participants, age 47.1±12.3 years (age range 27-69 years) and arm circumference 30.0±4.4 cm, had a mean systolic blood pressure (SBP) of 143.9±27.4 mmHg and a mean diastolic blood pressure (DBP) of 90.1±18.3 mmHg. The device passed all of the requirements fulfilling the standards of the protocol, and the mean±SD device-observer difference was 2.8±4.2 mmHg for SBP and -0.4±3.5 mmHg for DBP. According to the results of the validation study on the basis of the ESH-IP revision 2010, the iHealth BP3 can be recommended for clinic use and self-measurement in an adult population. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  17. Blood pressure, excess weight and level of physical activity in students of a public university.

    PubMed

    Martins, Maria do Carmo de Carvalho e; Ricarte, Irapuá Ferreira; Rocha, Cláudio Henrique Lima; Maia, Rodrigo Batista; Silva, Vitor Brito da; Veras, André Bastos; Filho, Manoel Dias de Souza

    2010-08-01

    High blood pressure, excess weight and sedentary lifestyle are important risk factors for cardiovascular diseases, and they are closely associated. To evaluate the nutritional status, level of physical activity and blood pressure levels of students of Universidade Federal do Piauí, Teresina, Brazil. Cross-sectional study with a sample of 605 students (46.1% males and 53.9% females), with a mean age of 21.7 ± 3.7 years. The nutritional status was classified according to body mass index (BMI), and central adiposity according to waist circumference (WC). The level of physical activity was evaluated using the short version of the International Physical Activity Questionnaire (IPAQ). Elevated blood pressure was defined as systolic blood pressure > 140 mmHg and/or diastolic blood pressure ≥ 90 mmHg. The prevalence of elevated blood pressure was 9.7%, and was higher among men. Excess weight (BMI > 25 kg/m(2)) was found in 18.2% of the students, with overweight and obesity rates of 15.2% and 3%, respectively. Abdominal obesity was found in 2.4% of the students regardless of gender, and sedentary lifestyle in 52%. The mean blood pressure increased with increasing BMI and WC. No association was found between the levels of physical activity and blood pressure. An association of increased body weight and waist circumference with higher blood pressure levels was observed among the participants. Instruments for an early assessment of the cardiovascular risk and preventive advice should be established for these young individuals.

  18. Elevation of internal auditory canal pressure by vestibular schwannomas.

    PubMed

    Badie, B; Pyle, G M; Nguyen, P H; Hadar, E J

    2001-09-01

    The exact mechanism of hearing loss, the most common presenting symptom in patients with vestibular schwannomas, remains unclear. To test whether increased pressure in the internal auditory canal from tumor growth is responsible for this clinical finding, the intracanalicular pressure in patients harboring these tumors was measured. Prospective study. Tertiary referral hospital. Fifteen consecutive patients undergoing a retrosigmoid approach for resection of vestibular schwannomas were included in the study. The intracanalicular pressure in every patient was measured by introducing a pressure microsensor into the internal auditory canal. The pressure readings, which were performed before tumor resection, were then correlated with tumor size and respective preoperative hearing status. Placement of the pressure monitor into the internal auditory canal revealed a biphasic waveform in every patient. Whereas the mean intracanalicular pressure was 20 mm Hg, there was significant variability among patients (range, 1-45 mm Hg). The intracanalicular pressure directly correlated with the amount of tumor in the internal auditory canal (r > 0.63, p < 0.012) but not with the total tumor size (r 0.075). Furthermore, eight patients with class A preoperative hearing (American Academy of Otolaryngology-Head and Neck Surgery classification) had lower intracanalicular pressures than did five patients with class B hearing (16 +/- 5 vs. 28 +/- 4). Although this observation suggested an inverse correlation between the intracanalicular pressure and hearing function, the difference between the two groups was not statistically significant (p = 0.14). Pressure on the cochlear nerve as a result of tumor growth in the internal auditory canal may be responsible for hearing loss in patients with vestibular schwannomas. Modification of surgical techniques to address the elevated intracanalicular pressure may be beneficial in improving hearing preservation in these patients.

  19. Effects of turn region treatments on pressure loss through sharp 180-degree bends

    NASA Astrophysics Data System (ADS)

    Plevich, C. W.; Metzger, D. E.

    An experimental study was conducted to evaluate the effect of geometric turn region inserts on pressure losses for flow through sharp 180-degree channel turns typical of internal cooling passages in gas turbine engine airfoils. The experiments were conducted in a rectangular cross-sectioned channel with 90-degree transverse rib roughening in both inlet and outlet legs, starting with completely smooth turn regions and progressing through various modifications including corner fillets, radial ribs, and turning vanes. The results show that modifications to the turn region geometry, particularly the inclusion of a single semi-circular turning vane, significantly reduce the pressure losses associated with coolant flows through sharp 180-degree turns and therefore can result in increased coolant flow for a given coolant supply pressure.

  20. Measurement of lower leg compression in vivo: recommendations for the performance of measurements of interface pressure and stiffness: consensus statement.

    PubMed

    Partsch, Hugo; Clark, Michael; Bassez, Sophie; Benigni, Jean-Patrick; Becker, Francis; Blazek, Vladimir; Caprini, Joseph; Cornu-Thénard, André; Hafner, Jürg; Flour, Mieke; Jünger, Michael; Moffatt, Christine; Neumann, Martino

    2006-02-01

    Interface pressure and stiffness characterizing the elastic properties of the material are the parameters determining the dosage of compression treatment and should therefore be measured in future clinical trials. To provide some recommendations regarding the use of suitable methods for this indication. This article was formulated based on the results of an international consensus meeting between a group of medical experts and representatives from the industry held in January 2005 in Vienna, Austria. Proposals are made concerning methods for measuring the interface pressure and for assessing the stiffness of a compression device in an individual patient. In vivo measurement of interface pressure is encouraged when clinical and experimental outcomes of compression treatment are to be evaluated.

  1. Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension.

    PubMed

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Ibanez, Isabel; Khabouth, Jose; Khawaja, Salwa; Beaino, Layale; Asmar, Roland

    2011-01-01

    Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP) at the brachial level, while the Omron R2 measures BP at the wrist level. The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010-2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely. All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and -1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and -0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and -1.1 ± 4.8 and -0.9 ± 4.3 mmHg using the Omron R2. Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.

  2. The intensity of knock in an internal combustion engine: An experimental and modeling study

    NASA Astrophysics Data System (ADS)

    Cowart, J. S.; Haghooie, M.; Newman, C. E.; Davis, G. C.; Pitz, W. J.; Westbrook, C. K.

    1992-09-01

    Experimental data have been obtained that characterize knock occurrence times and knock intensities in a spark ignition engine operating on indolene and 91 primary reference fuel, as spark timing and inlet temperature were varied. Individual, in-cylinder pressure histories measured under knocking conditions were conditioned and averaged to obtain representative pressure traces. These averaged pressure histories were used as input to a reduced and detailed chemical kinetic model. The time derivative of CO concentration and temperature were correlated with the measured knock intensity and percent cycles knocking. The goal was to evaluate the potential of using homogeneous, chemical kinetic models as predictive tools for knock intensity.

  3. A Critical Evaluation of the Thermophysical Properties of Mercury

    NASA Astrophysics Data System (ADS)

    Holman, G. J. F.; ten Seldam, C. A.

    1994-09-01

    For the use of a mercury column for precise pressure measurements—such as the pressurized 30 meter mercury-in-steel column used at the Van der Waals-Zeeman Laboratory for the calibration of piston gauges up to nearly 300 MPa—it is highly important to have accurate knowledge of such properties of mercury as density, isobaric secant and tangent volume thermal expansion coefficients, and isothermal secant and tangent compressibilities as functions of temperature and pressure. In this paper we present a critical assessment of the available information on these properties. Recommended values are given for the properties mentioned and, in addition, for properties derived from theses such as entropy, enthalpy, internal energy, and the specific heat capacities.

  4. Marketing therapeutic recreation services.

    PubMed

    Thorn, B E

    1984-01-01

    The use of marketing strategies can enhance the delivery of therapeutic recreation services. This article discusses how agencies can adapt marketing techniques and use them to identify potential markets, improve image, evaluate external pressures, and maximize internal strengths. Four variables that can be controlled and manipulated in a proposed marketing plan are product, price, place and promotion.

  5. Damage Control Resuscitation Supplemented with Vasopressin in a Severe Polytrauma Model with Traumatic Brain Injury and Uncontrolled Internal Hemorrhage.

    PubMed

    Dickson, J Michael; Wang, Xu; St John, Alexander E; Lim, Esther B; Stern, Susan A; White, Nathan J

    2018-03-14

    Traumatic brain injury (TBI) and hemorrhagic shock (HS) are the leading causes of traumatic death worldwide and particularly on the battlefield. They are especially challenging when present simultaneously (polytrauma), and clear blood pressure end points during fluid resuscitation are not well described for this situation. The goal of this study is to evaluate for any benefit of increasing blood pressure using a vasopressor on brain blood flow during initial fluid resuscitation in a swine polytrauma model. We used a swine polytrauma model with simultaneous TBI, femur fracture, and HS with uncontrolled noncompressible internal bleeding from an aortic tear injury. Five animals were assigned to each of three experimental groups (hydroxyethyl starch only [HES], HES + 0.4 U/kg vasopressin, and no fluid resuscitation [No Fluids]). Fluids were given as two 10 mL/kg boluses according to tactical field care guidelines. Primary outcomes were mean arterial blood pressure (MAP) and brain blood flow at 60 min. Secondary outcomes were blood flows in the heart, intestine, and kidney; arterial blood lactate level; and survival at 6 hr. Organ blood flow was measured using injection of colored microspheres. Five animals were tested in each of the three groups. There was a statistically significant increase in MAP with vasopressin compared with other experimental groups, but no significant increase in brain blood flow during the first 60 min of resuscitation. The vasopressin group also exhibited greater total internal hemorrhage volume and rate. There was no difference in survival at 6 hours. In this experimental swine polytrauma model, increasing blood pressure with vasopressin did not improve brain perfusion, likely due to increased internal hemorrhage. Effective hemostasis should remain the top priority for field treatment of the polytrauma casualty with TBI.

  6. Excessive glenohumeral horizontal abduction as occurs during the late cocking phase of the throwing motion can be critical for internal impingement.

    PubMed

    Mihata, Teruhisa; McGarry, Michelle H; Kinoshita, Mitsuo; Lee, Thay Q

    2010-02-01

    The objective of this study was to determine the effects of increased horizontal abduction with maximum external rotation, as occurs during the late cocking phase of throwing motion, on shoulder internal impingement. An increase in glenohumeral horizontal abduction will cause overlap of the rotator cuff insertion with respect to the glenoid and increase pressure between the supraspinatus and infraspinatus tendon insertions on the greater tuberosity and the glenoid. Controlled laboratory study. Eight cadaveric shoulders were tested with a custom shoulder testing system with the specimens in 60 degrees of glenohumeral abduction and maximum external rotation. The amount of internal impingement was evaluated by assessing the location of the supraspinatus and infraspinatus articular insertions on the greater tuberosity relative to the glenoid using a MicroScribe 3DLX. Pressure in the posterior-superior quadrant of the glenoid was measured using Fuji prescale film. Data were obtained with the humerus in the scapular plane and 15 degrees , 30 degrees , and 45 degrees of horizontal abduction from the scapular plane. At 30 degrees and 45 degrees of horizontal abduction, the articular margin of the supraspinatus and infraspinatus tendons was anterior to the posterior edge of the glenoid and less than 2 mm from the glenoid rim in the lateral direction; the contact pressure was also greater than that found in the scapular plane and 15 degrees of horizontal abduction. Conclusion Horizontal abduction beyond the coronal plane increased the amount of overlap and contact pressure between the supraspinatus and infraspinatus tendons and glenoid. Excessive glenohumeral horizontal abduction beyond the coronal plane may cause internal impingement, which may lead to rotator cuff tears and superior labral anterior to posterior (SLAP) lesions.

  7. Negative pressures and spallation in water drops subjected to nanosecond shock waves

    DOE PAGES

    Stan, Claudiu A.; Willmott, Philip R.; Stone, Howard A.; ...

    2016-05-16

    Most experimental studies of cavitation in liquid water at negative pressures reported cavitation at tensions significantly smaller than those expected for homogeneous nucleation, suggesting that achievable tensions are limited by heterogeneous cavitation. We generated tension pulses with nanosecond rise times in water by reflecting cylindrical shock waves, produced by X-ray laser pulses, at the internal surface of drops of water. Depending on the X-ray pulse energy, a range of cavitation phenomena occurred, including the rupture and detachment, or spallation, of thin liquid layers at the surface of the drop. When spallation occurred, we evaluated that negative pressures below –100 MPamore » were reached in the drops. As a result, we model the negative pressures from shock reflection experiments using a nucleation-and-growth model that explains how rapid decompression could outrun heterogeneous cavitation in water, and enable the study of stretched water close to homogeneous cavitation pressures.« less

  8. Bounding the Risk of Crew Loss Following Orbital Debris Penetration of the International Space Station at Assembly Stages 1J and 1E

    NASA Technical Reports Server (NTRS)

    Evans, S.; Lewis, H.; Williamsen, J.; Evans, H.; Bohl, W.; Parker, Nelson (Technical Monitor)

    2002-01-01

    Orbital debris impacts on the International Space Station occur frequently. To date, none of the impacting particles has been sufficiently large to penetrate manned pressurized volumes. We used the Manned Spacecraft Crew Survivability code to evaluate the risk to crew of penetrations of pressurized modules at two assembly stages: after Flight lJ, when the pressurized elements of Kibo, the Japanese Experiment Module, are present, and after Flight lE, when the European Columbus Module is present. Our code is a Monte Carlo simulation of impacts on the Station that considers several potential event types that could lead to crew loss. Among the statistics tabulated by the program is the probability of death of one or more crew members, expressed as the risk factor, R. This risk factor is dependent on details of crew operations during both ordinary circumstances and decompression emergencies, as well as on details of internal module configurations. We conducted trade studies considering these procedure and configuration details to determine the bounds on R at the 1J and 1E stages in the assembly sequence. Here we compare the R-factor bounds, and procedures and configurations that reduce R at these stages.

  9. Finite Element Modeling of the NASA Langley Aluminum Testbed Cylinder

    NASA Technical Reports Server (NTRS)

    Grosveld, Ferdinand W.; Pritchard, Joselyn I.; Buehrle, Ralph D.; Pappa, Richard S.

    2002-01-01

    The NASA Langley Aluminum Testbed Cylinder (ATC) was designed to serve as a universal structure for evaluating structural acoustic codes, modeling techniques and optimization methods used in the prediction of aircraft interior noise. Finite element models were developed for the components of the ATC based on the geometric, structural and material properties of the physical test structure. Numerically predicted modal frequencies for the longitudinal stringer, ring frame and dome component models, and six assembled ATC configurations were compared with experimental modal survey data. The finite element models were updated and refined, using physical parameters, to increase correlation with the measured modal data. Excellent agreement, within an average 1.5% to 2.9%, was obtained between the predicted and measured modal frequencies of the stringer, frame and dome components. The predictions for the modal frequencies of the assembled component Configurations I through V were within an average 2.9% and 9.1%. Finite element modal analyses were performed for comparison with 3 psi and 6 psi internal pressurization conditions in Configuration VI. The modal frequencies were predicted by applying differential stiffness to the elements with pressure loading and creating reduced matrices for beam elements with offsets inside external superelements. The average disagreement between the measured and predicted differences for the 0 psi and 6 psi internal pressure conditions was less than 0.5%. Comparably good agreement was obtained for the differences between the 0 psi and 3 psi measured and predicted internal pressure conditions.

  10. Evaluation of a new geriatric foot versus the Solid Ankle Cushion Heel foot for low-activity amputees.

    PubMed

    Bonnet, Xavier; Adde, Jean N; Blanchard, François; Gedouin-Toquet, Annick; Eveno, Dominique

    2015-04-01

    It is always a challenge to rehabilitate geriatric amputees to perform self-care skills at home with limited ambulation. A new geriatric foot (with a lower effective foot length) has been specifically designed to reduce residual limb stress and to ease the step completion. The aim of this study is to evaluate the benefit of a new geriatric foot versus a Solid Ankle Cushion Heel foot for low-activity persons with transtibial amputation. Crossover study. A total of 12 patients were included in this study. 2-min walking test, Quebec User Evaluation of Satisfaction with Assistive Technology 2.0 questionnaire and pressure socket measurements. The geriatric foot allows for greater patient satisfaction. The maximal pressure was significantly lower in the proximal anterior stump area. No statistical differences were obtained from the 2-min walking test. A geriatric foot designed with a low effective foot length improves the satisfaction and reduces proximal anterior socket pressures for poor-performing persons with transtibial amputation. The development and evaluation of feet specifically designed for geriatric persons with transtibial amputation could improve their specific requirements and satisfaction. © The International Society for Prosthetics and Orthotics 2014.

  11. Space shuttle solid rocket booster water entry cavity collapse loads

    NASA Technical Reports Server (NTRS)

    Keefe, R. T.; Rawls, E. A.; Kross, D. A.

    1982-01-01

    Solid rocket booster cavity collapse flight measurements included external pressures on the motor case and aft skirt, internal motor case pressures, accelerometers located in the forward skirt, mid-body area, and aft skirt, as well as strain gages located on the skin of the motor case. This flight data yielded applied pressure longitudinal and circumferential distributions which compare well with model test predictions. The internal motor case ullage pressure, which is below atmospheric due to the rapid cooling of the hot internal gas, was more severe (lower) than anticipated due to the ullage gas being hotter than predicted. The structural dynamic response characteristics were as expected. Structural ring and wall damage are detailed and are considered to be attributable to the direct application of cavity collapse pressure combined with the structurally destabilizing, low internal motor case pressure.

  12. Effects of press sizes on internal steam pressure during particleboard hot-pressing process

    Treesearch

    Zhiyong Cai; Michael Birkeland; James M. Wescott; Jane O' Dell; Jerrold E. Winandy

    2009-01-01

    Internal steam pressure produced during the hot-pressing cycle in particleboard production is critical to the newly developed bond strength that will determine the overall performance of particleboard. The difference between the accumulation of internal steam pressure for small panels made in the laboratory and that of large commercial-sized panels makes it difficult...

  13. Hydrogen environment embrittlement

    NASA Technical Reports Server (NTRS)

    Gray, H. R.

    1972-01-01

    Hydrogen embrittlement is classified into three types: internal reversible hydrogen embrittlement, hydrogen reaction embrittlement, and hydrogen environment embrittlement. Characteristics of and materials embrittled by these types of hydrogen embrittlement are discussed. Hydrogen environment embrittlement is reviewed in detail. Factors involved in standardizing test methods for detecting the occurrence of and evaluating the severity of hydrogen environment embrittlement are considered. The effect of test technique, hydrogen pressure, purity, strain rate, stress concentration factor, and test temperature are discussed. Additional research is required to determine whether hydrogen environment embrittlement and internal reversible hydrogen embrittlement are similar or distinct types of embrittlement.

  14. Flow Control Device Evaluation for an Internal Flow with an Adverse Pressure Gradient

    NASA Technical Reports Server (NTRS)

    Jenkins, Luther N.; Gorton, Susan Althoff; Anders, Scott G.

    2002-01-01

    The effectiveness of several active and passive devices to control flow in an adverse pressure gradient with secondary flows present was evaluated in the 15 Inch Low Speed Tunnel at NASA Langley Research Center. In this study, passive micro vortex generators, micro bumps, and piezoelectric synthetic jets were evaluated for their flow control characteristics using surface static pressures, flow visualization, and 3D Stereo Digital Particle Image Velocimetry. Data also were acquired for synthetic jet actuators in a zero flow environment. It was found that the micro vortex generator is very effective in controlling the flow environment for an adverse pressure gradient, even in the presence of secondary vortical flow. The mechanism by which the control is effected is a re-energization of the boundary layer through flow mixing. The piezoelectric synthetic jet actuators must have sufficient velocity output to produce strong longitudinal vortices if they are to be effective for flow control. The output of these devices in a laboratory or zero flow environment will be different than the output in a flow environment. In this investigation, the output was higher in the flow environment, but the stroke cycle in the flow did not indicate a positive inflow into the synthetic jet.

  15. Anal endosonography and manometry: comparison in patients with defecation problems.

    PubMed

    Schäfer, R; Heyer, T; Gantke, B; Schäfer, A; Frieling, T; Häussinger, D; Enck, P

    1997-03-01

    Correlations between anal sphincter function as assessed by anorectal manometry and anal sphincter anatomy measured by endoluminal ultrasound have been reported in the literature both for patients and for healthy individuals but have not been confirmed by other authors. For a larger series of patients (152 consecutive patients, mean age 54.1 +/- 15.5 years; female:male ratio, 111:41) with anorectal dysfunctions such as incontinence (n = 92), constipation (n = 37), and other symptoms (n = 23), diagnostic work-up included conventional multilumen anorectal manometry to evaluate internal sphincter pressure at rest, maximum external sphincter squeeze pressure during contraction, and endoanal sonography to determine anal sphincter integrity and to measure dorsal, left lateral, and right lateral diameter of the internal anal sphincter (IAS) and external anal sphincter (EAS) muscles. Maximum squeeze pressure was significantly correlated to muscle thickness of the EAS (P = 0.001). No association was found between resting pressure and IAS diameter. Women had significantly lower resting and squeeze pressures than men (P = 0.008 and P = 0.003, respectively), but age-related changes of function were only found for resting pressure. Endosonographic values of IAS and EAS did not differ between genders but were significantly correlated with age (P = 0.008 and P = 0.02, respectively). Because all correlations were rather weak, they only can explain a small portion of data variance. Anal manometry and anal ultrasound, therefore, are of complementary value and are both indicated in adequate clinical problems.

  16. The computational modeling of supercritical carbon dioxide flow in solid wood material

    NASA Astrophysics Data System (ADS)

    Gething, Brad Allen

    The use of supercritical carbon dioxide (SC CO2) as a solvent to deliver chemicals to porous media has shown promise in various industries. Recently, efforts by the wood treating industry have been made to use SC CO 2 as a replacement to more traditional methods of chemical preservative delivery. Previous studies have shown that the SC CO2 pressure treatment process is capable of impregnating solid wood materials with chemical preservatives, but concentration gradients of preservative often develop during treatment. Widespread application of the treatment process is unlikely unless the treatment inconsistencies can be improved for greater overall treating homogeneity. The development of a computational flow model to accurately predict the internal pressure of CO2 during treatment is integral to a more consistent treatment process. While similar models that attempt to describe the flow process have been proposed by Ward (1989) and Sahle-Demessie (1994), neither have been evaluated for accuracy. The present study was an evaluation of those models. More specifically, the present study evaluated the performance of a computational flow model, which was based on the viscous flow of compressible CO2 as a single phase through a porous medium at the macroscopic scale. Flow model performance was evaluated through comparisons between predicted pressures that corresponded to internal pressure development measured with inserted sensor probes during treatment of specimens. Pressure measurements were applied through a technique developed by Schneider (2000), which utilizes epoxy-sealed stainless steel tubes that are inserted into the wood as pressure probes. Two different wood species were investigated as treating specimens, Douglas-fir and shortleaf pine. Evaluations of the computational flow model revealed that it is sensitive to input parameters that relate to both processing conditions and material properties, particularly treating temperature and wood permeability, respectively. This sensitivity requires that the input parameters, principally permeability, be relatively accurate to evaluate the appropriateness of the phenomenological relationships of the computational flow model. Providing this stipulation, it was observed that below the region of transition from CO2 gas to supercritical fluid, the computational flow model has the potential to predict flow accurately. However, above the transition region, the model does not fully account for the physics of the flow process, resulting in prediction inaccuracy. One potential cause for the loss of prediction accuracy in the supercritical region was attributed to a dynamic change in permeability that is likely caused by an interaction between the flowing SC CO2 and the wood material. Furthermore, a hysteresis was observed between the pressurization and depressurization stages of treatment, which cannot be explained by the current flow model. If greater accuracy in the computational flow model is desired, a more complex approach to the model is necessary, which would include non-constant input parameters of temperature and permeability. Furthermore, the implications of a multi-scale methodology for the flow model were explored from a qualitative standpoint.

  17. Blood pressure normalization post-jugular venous balloon angioplasty.

    PubMed

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the association between blood pressure deviation and internal jugular veins narrowing, and whether blood pressure normalization affects Patient's clinical outcomes. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-housemore » air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  19. Correlation between auditory function and internal auditory canal pressure in patients with vestibular schwannomas.

    PubMed

    Lapsiwala, Samir B; Pyle, G Mark; Kaemmerle, Ann W; Sasse, Frank J; Badie, Behnam

    2002-05-01

    Hearing loss is the most common presenting symptom in patients who harbor a vestibular schwannoma (VS). Although mechanical injury to the cochlear nerve and vascular compromise of the auditory apparatus have been proposed, the exact mechanism of this hearing loss remains unclear. To test whether pressure on the cochlear nerve from tumor growth in the internal auditory canal (IAC) is responsible for this clinical finding, the authors prospectively evaluated intracanalicular pressure (ICaP) in patients with VS and correlated this with preoperative brainstem response. In 40 consecutive patients undergoing a retrosigmoid-transmeatal approach for tumor excision, ICaP was measured by inserting a pressure microsensor into the IAC before any tumor manipulation. Pressure recordings were correlated with tumor size and preoperative auditory evoked potential (AEP) recordings. The ICaP, which varied widely among patients (range 0-45 mm Hg), was significantly elevated in most patients (median 16 mm Hg). Although these pressure measurements directly correlated to the extension of tumor into the IAC (p = 0.001), they did not correlate to total tumor size (p = 0.2). In 20 patients in whom baseline AEP recordings were available, the ICaP directly correlated to wave V latency (p = 0.0001), suggesting that pressure from tumor growth in the IAC may be responsible for hearing loss in these patients. Tumor growth into the IAC results in elevation of ICaP and may play a role in hearing loss in patients with VS. The relevance of these findings to the surgical treatment of these tumors is discussed.

  20. Development of a Pressure Box to Evaluate Reusable-Launch-Vehicle Cryogenic-Tank Panels

    NASA Technical Reports Server (NTRS)

    Ambur, Damodar R.; Sikora, Joseph; Maguire, James F.; Winn, Peter M.

    1996-01-01

    A cryogenic pressure-box test machine has been designed and is being developed to test full-scale reusable-launch-vehicle cryogenic-tank panels. This machine is equipped with an internal pressurization system, a cryogenic cooling system, and a heating system to simulate the mechanical and thermal loading conditions that are representative of a reusable-launch-vehicle mission profile. The cryogenic cooling system uses liquid helium and liquid nitrogen to simulate liquid hydrogen and liquid oxygen tank internal temperatures. A quartz lamp heating system is used for heating the external surface of the test panels to simulate cryogenic-tank external surface temperatures during re-entry of the launch vehicle. The pressurization system uses gaseous helium and is designed to be controlled independently of the cooling system. The tensile loads in the axial direction of the test panel are simulated by means of hydraulic actuators and a load control system. The hoop loads in the test panel are reacted by load-calibrated turnbuckles attached to the skin and frame elements of the test panel. The load distribution in the skin and frames can be adjusted to correspond to the tank structure by using these turnbuckles. The seal between the test panel and the cryogenic pressure box is made from a reinforced Teflon material which can withstand pressures greater than 52 psig at cryogenic temperatures. Analytical results and tests on prototype test components indicate that most of the cryogenic-tank loading conditions that occur in flight can be simulated in the cryogenic pressure-box test machine.

  1. The Effect of Internal Pressure on the Buckling Stress of Thin-Walled Circular Cylinders Under Torsion

    NASA Technical Reports Server (NTRS)

    Crate, Harold; Batdorf, S B; Baab, George W

    1944-01-01

    The results of a series of tests to determine the effect of internal pressure on the buckling load of a thin cylinder under an applied torque indicated that internal pressure raises the shear buckling stress. The experimental results were analyzed with the aid of previously developed theory and a simple interaction formula was derived. (author)

  2. Distribution of internal pressure around bony prominences: implications to deep tissue injury and effectiveness of intermittent electrical stimulation.

    PubMed

    Solis, Leandro R; Liggins, Adrian; Uwiera, Richard R E; Poppe, Niek; Pehowich, Enid; Seres, Peter; Thompson, Richard B; Mushahwar, Vivian K

    2012-08-01

    The overall goal of this project is to develop interventions for the prevention of deep tissue injury (DTI), a form of pressure ulcers that originates in deep tissue around bony prominences. The present study focused on: (1) obtaining detailed measures of the distribution of pressure experienced by tissue around the ischial tuberosities, and (2) investigating the effectiveness of intermittent electrical stimulation (IES), a novel strategy for the prevention of DTI, in alleviating pressure in regions at risk of breakdown due to sustained loading. The experiments were conducted in adult pigs. Five animals had intact spinal cords and healthy muscles and one had a spinal cord injury that led to substantial muscle atrophy at the time of the experiment. A force-controlled servomotor was used to load the region of the buttocks to levels corresponding to 25%, 50% or 75% of each animal's body weight. A pressure transducer embedded in a catheter was advanced into the tissue to measure pressure along a three dimensional grid around the ischial tuberosity of one hind leg. For all levels of external loading in intact animals, average peak internal pressure was 2.01 ± 0.08 times larger than the maximal interfacial pressure measured at the level of the skin. In the animal with spinal cord injury, similar absolute values of internal pressure as that in intact animals were recorded, but the substantial muscle atrophy produced larger maximal interfacial pressures. Average peak internal pressure in this animal was 1.43 ± 0.055 times larger than the maximal interfacial pressure. Peak internal pressure was localized within a ±2 cm region medio-laterally and dorso-ventrally from the bone in intact animals and ±1 cm in the animal with spinal cord injury. IES significantly redistributed internal pressure, shifting the peak values away from the bone in spinally intact and injured animals. These findings provide critical information regarding the relationship between internal and interfacial pressure around the ischial tuberosities during loading levels equivalent to those experienced while sitting. The information could guide future computer models investigating the etiology of DTI, as well as inform the design and prescription of seating cushions for people with reduced mobility. The findings also suggest that IES may be an effective strategy for the prevention of DTI.

  3. Wind Tunnel Results from a Nozzle Afterbody Test of a 0.2-Scale Fighter Aircraft in the Mach Number Regime of 0.6 to 1.5. Volume 1. Test Technique Evaluation

    DTIC Science & Technology

    1979-04-01

    edge up. The influence of the aircraft on the static pressure reading from the pitot boom was determined with a scaled version of the pltot probe...stabilization before advancing to the next port. Jet exhaust simulation flow was monitored by internal duct pressure and temperature rakes . Standard...Mach numbers 0.6 and 1.2, Figs. 24 and 25. 13 AE DC-TR-79-10 At supersonic speeds, changes in the afterbody and nozzle axial loads (Fig. 22b) are

  4. Internal Flow and Burning Characteristics of 16-inch Ram Jet Operating in a Free Jet at Mach Numbers of 1.35 and 1.73

    NASA Technical Reports Server (NTRS)

    Perchonok, Eugene; Farley, John M

    1951-01-01

    The effects of mass-flow ratio on the additive drag and normal-shock position of a single oblique-shock diffuser are presented. Also evaluated is the variation with operating condition of the velocity distribution at the combustion-chamber inlet. A comparison with connected-pipe data is included. Burner performance with a corrugated gutter-grid flame holder is discussed. It is shown that the total-pressure drop across the combustion chamber can be predicted with reasonable accuracy from the computed flame holder and combustion momentum pressure losses.

  5. Fluid dynamic modeling of junctions in internal combustion engine inlet and exhaust systems

    NASA Astrophysics Data System (ADS)

    Chalet, David; Chesse, Pascal

    2010-10-01

    The modeling of inlet and exhaust systems of internal combustion engine is very important in order to evaluate the engine performance. This paper presents new pressure losses models which can be included in a one dimensional engine simulation code. In a first part, a CFD analysis is made in order to show the importance of the density in the modeling approach. Then, the CFD code is used, as a numerical test bench, for the pressure losses models development. These coefficients depend on the geometrical characteristics of the junction and an experimental validation is made with the use of a shock tube test bench. All the models are then included in the engine simulation code of the laboratory. The numerical calculation of unsteady compressible flow, in each pipe of the inlet and exhaust systems, is made and the calculated engine torque is compared with experimental measurements.

  6. Multi-Scaled Modeling the Mechanical Properties of Tubular Composites Reinforced with Innovated 3D Weft Knitted Spacer Fabrics

    NASA Astrophysics Data System (ADS)

    Omrani, Elahe; Hasani, Hossein; Dibajian, Sayed Houssain

    2018-02-01

    Textile composites of 3D integrated spacer configurations have been recently focused by several researchers all over the world. In the present study, newly-designed tubular composites reinforced with 3D spacer weft knitted fabrics were considered and the effects of their structural parameters on some applicable mechanical properties were investigated. For this purpose, two different samples of 3D spacer weft knitted textile types in tubular form were produced on an electronic flat knitting machine, using glass/nylon hybrid yarns. Thermoset tubular-shaped composite parts were manufactured via vacuum infusion molding process using epoxy resin. The mechanical properties of the produced knitted composites in term of external static and internal hydrostatic pressures were evaluated. Resistance of the produced composites against the external static and internal hydrostatic pressures was numerically simulated using multi-scale modeling method. The finding revealed that there is acceptable correlation between experimental and theoretical results.

  7. Performance evaluation of a second-generation elastic loop mobility system

    NASA Technical Reports Server (NTRS)

    Melzer, K. J.; Swanson, G. D.

    1974-01-01

    Tests were conducted to evaluate the mobility performance of a second-generation Elastic Loop Mobility System (ELMS II). Performance on level test lanes and slopes of lunar soil simulant (LSS) and obstacle-surmounting and crevasse-crossing capabilities were investigated. In addition, internal losses and contact pressure distributions were evaluated. To evaluate the soft-soil performance, two basic soil conditions were tested: loose (LSS1) and dense (LSS5). These conditions embrace the spectrum of soil strengths tested during recent studies for NASA related to the mobility performance of the LRV. Data indicated that for the tested range of the various performance parameters, performance was independent of unit load (contact pressure) and ELMS II drum angular velocity, but was influenced by soil strength and ELMS pitch mode. Power requirements were smaller at a given system output for dense soil than for loose soil. The total system output in terms of pull developed or slope-climbing capability was larger for the ELMS II operating in restrained-pitch mode than in free-pitch mode.

  8. Evaluation of the internal and external responsiveness of the Pressure Ulcer Scale for Healing (PUSH) tool for assessing acute and chronic wounds.

    PubMed

    Choi, Edmond P H; Chin, Weng Yee; Wan, Eric Y F; Lam, Cindy L K

    2016-05-01

    To examine the internal and external responsiveness of the Pressure Ulcer Scale for Healing (PUSH) tool for assessing the healing progress in acute and chronic wounds. It is important to establish the responsiveness of instruments used in conducting wound care assessments to ensure that they are able to capture changes in wound healing accurately over time. Prospective longitudinal observational study. The key study instrument was the PUSH tool. Internal responsiveness was assessed using paired t-testing and effect size statistics. External responsiveness was assessed using multiple linear regression. All new patients with at least one eligible acute or chronic wound, enrolled in the Nurse and Allied Health Clinic-Wound Care programme between 1 December 2012 - 31 March 2013 were included for analysis (N = 541). Overall, the PUSH tool was able to detect statistically significant changes in wound healing between baseline and discharge. The effect size statistics were large. The internal responsiveness of the PUSH tool was confirmed in patients with a variety of different wound types including venous ulcers, pressure ulcers, neuropathic ulcers, burns and scalds, skin tears, surgical wounds and traumatic wounds. After controlling for age, gender and wound type, subjects in the 'wound improved but not healed' group had a smaller change in PUSH scores than those in the 'wound healed' group. Subjects in the 'wound static or worsened' group had the smallest change in PUSH scores. The external responsiveness was confirmed. The internal and external responsiveness of the PUSH tool confirmed that it can be used to track the healing progress of both acute and chronic wounds. © 2016 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.

  9. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

    PubMed

    Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin

    2018-03-01

    The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

  10. Internal combustion engine for natural gas compressor operation

    DOEpatents

    Hagen, Christopher L.; Babbitt, Guy; Turner, Christopher; Echter, Nick; Weyer-Geigel, Kristina

    2016-04-19

    This application concerns systems and methods for compressing natural gas with an internal combustion engine. In a representative embodiment, a system for compressing a gas comprises a reciprocating internal combustion engine including at least one piston-cylinder assembly comprising a piston configured to travel in a cylinder and to compress gas in the cylinder in multiple compression stages. The system can further comprise a first pressure tank in fluid communication with the piston-cylinder assembly to receive compressed gas from the piston-cylinder assembly until the first pressure tank reaches a predetermined pressure, and a second pressure tank in fluid communication with the piston-cylinder assembly and the first pressure tank. The second pressure tank can be configured to receive compressed gas from the piston-cylinder assembly until the second pressure tank reaches a predetermined pressure. When the first and second pressure tanks have reached the predetermined pressures, the first pressure tank can be configured to supply gas to the piston-cylinder assembly, and the piston can be configured to compress the gas supplied by the first pressure tank such that the compressed gas flows into the second pressure tank.

  11. Air Leakage and Air Transfer Between Garage and Living Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, Armin

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.« less

  12. Internal combustion engine cylinder-to-cylinder balancing with balanced air-fuel ratios

    DOEpatents

    Harris, Ralph E.; Bourn, Gary D.; Smalley, Anthony J.

    2006-01-03

    A method of balancing combustion among cylinders of an internal combustion engine. For each cylinder, a normalized peak firing pressure is calculated as the ratio of its peak firing pressure to its combustion pressure. Each cylinder's normalized peak firing pressure is compared to a target value for normalized peak firing pressure. The fuel flow is adjusted to any cylinder whose normalized peak firing pressure is not substantially equal to the target value.

  13. International certification in developing countries: the role of internal and external institutional pressure.

    PubMed

    Fikru, Mahelet G

    2014-11-01

    This paper examines the different internal and external institutional factors that affect the decision of businesses in developing countries to adopt international certification (IC). Past studies focus on pressure from international laws, the role of multinationals, and businesses mimicking practices of their counterparts in developed countries. This paper finds that, in addition to these external factors, internal factors may have a significant role. Even though environmental regulation is weak in developing countries, governments do not ignore industrial pollution and casualties. They respond by increasing bureaucratic regulations for businesses and this can affect the decision to adopt IC. Furthermore, internal pressure may come from workers' unions that push for a safe and healthy working environment. Published by Elsevier Ltd.

  14. Investigation of Composite Structures

    NASA Technical Reports Server (NTRS)

    Hyer, Michael W.

    2000-01-01

    This final report consists of a compilation of four separate written documents, three dealing with the response and failure of elliptical composite cylinders to an internal pressure load, and the fourth dealing with the influence of manufacturing imperfections in curved composite panels. The three focused on elliptical cylinders consist of the following: 1 - A paper entitled "Progressive Failure Analysis of Internally Pressurized Elliptical Composite Cylinders," 2 - A paper entitled "Influence of Geometric Nonlinearities on the Response and Failure of Internally Pressurized Elliptical Composite Cylinders," and 3 - A report entitled "Response and Failure of Internally Pressurized Elliptical Composite Cyclinders." The document which deals with the influence of manufacturing imperfections is a paper entitled "Manufacturing Distortions of Curved Composite Panels."

  15. Determination of combustion parameters using engine crankshaft speed

    NASA Astrophysics Data System (ADS)

    Taglialatela, F.; Lavorgna, M.; Mancaruso, E.; Vaglieco, B. M.

    2013-07-01

    Electronic engine controls based on real time diagnosis of combustion process can significantly help in complying with the stricter and stricter regulations on pollutants emissions and fuel consumption. The most important parameter for the evaluation of combustion quality in internal combustion engines is the in-cylinder pressure, but its direct measurement is very expensive and involves an intrusive approach to the cylinder. Previous researches demonstrated the direct relationship existing between in-cylinder pressure and engine crankshaft speed and several authors tried to reconstruct the pressure cycle on the basis of the engine speed signal. In this paper we propose the use of a Multi-Layer Perceptron neural network to model the relationship between the engine crankshaft speed and some parameters derived from the in-cylinder pressure cycle. This allows to have a non-intrusive estimation of cylinder pressure and a real time evaluation of combustion quality. The structure of the model and the training procedure is outlined in the paper. A possible combustion controller using the information extracted from the crankshaft speed information is also proposed. The application of the neural network model is demonstrated on a single-cylinder spark ignition engine tested in a wide range of speeds and loads. Results confirm that a good estimation of some combustion pressure parameters can be obtained by means of a suitable processing of crankshaft speed signal.

  16. Bounding the risk of crew loss following orbital debris penetration of the International Space Station at assembly stages 1J and 1E.

    PubMed

    Evans, S; Lewis, H; Williamsen, J; Evans, H; Bohl, W

    2004-01-01

    Orbital debris impacts on the International Space Station occur frequently. To date, none of the impacting particles has been large enough to penetrate manned pressurized volumes. We used the Manned Spacecraft Crew Survivability code to evaluate the risk to crew of penetrations of pressurized modules at two assembly stages: after Flight 1J, when the pressurized elements of Kibo, the Japanese Experiment Module, are present, and after Flight 1E, when the European Columbus Module is present. Our code is a Monte-Carlo simulation of impacts on the Station that considers several potential event types that could lead to crew loss. Among the statistics tabulated by the program is the probability of death of one or more crew members in the event of a penetration, expressed as the risk factor, R. This risk factor is dependent on details of crew operations during both ordinary circumstances and decompression emergencies, as well as on details of internal module configurations. We conducted trade studies considering these procedure and configuration details to determine the bounds on R at the 1J and 1E stages in the assembly sequence. Here we compare the R-factor bounds, and procedures could that reduce R at these stages. Published by Elsevier Ltd on behalf of COSPAR.

  17. Bounding the risk of crew loss following orbital debris penetration of the International Space Station at assembly stages 1J and 1E

    NASA Technical Reports Server (NTRS)

    Evans, S.; Lewis, H.; Williamsen, J.; Evans, H.; Bohl, W.

    2004-01-01

    Orbital debris impacts on the International Space Station occur frequently. To date, none of the impacting particles has been large enough to penetrate manned pressurized volumes. We used the Manned Spacecraft Crew Survivability code to evaluate the risk to crew of penetrations of pressurized modules at two assembly stages: after Flight 1J, when the pressurized elements of Kibo, the Japanese Experiment Module, are present, and after Flight 1E, when the European Columbus Module is present. Our code is a Monte-Carlo simulation of impacts on the Station that considers several potential event types that could lead to crew loss. Among the statistics tabulated by the program is the probability of death of one or more crew members in the event of a penetration, expressed as the risk factor, R. This risk factor is dependent on details of crew operations during both ordinary circumstances and decompression emergencies, as well as on details of internal module configurations. We conducted trade studies considering these procedure and configuration details to determine the bounds on R at the 1J and 1E stages in the assembly sequence. Here we compare the R-factor bounds, and procedures could that reduce R at these stages. Published by Elsevier Ltd on behalf of COSPAR.

  18. Validation of the Andon KD5031 for clinical use and self-measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye

    2016-10-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor Andon KD5031 for home BP monitoring according to the European Society of Hypertension International Protocol revision 2010. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using the standard mercury sphygmomanometer and the Andon KD5031 device. Ninety-nine pairs of comparisons were obtained from 33 participants for analysis. The KD5031 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10, and 15 mmHg was 66/99, 93/99, and 98/99, respectively, for SBP and 72/99, 94/99, and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. Twenty-six participants for both SBP and DBP had at least two of the three device-observer differences within 5 mmHg (required ≥24). The number of participants without a device-observer difference within 5 mmHg was one for SBP and three for DBP (required ≤3). The Andon upper arm BP monitor KD5031 has passed the International Protocol requirements, and it can be recommended for clinical use and self-measurement in adults.

  19. MB3a Infrasound Sensor Evaluation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Bion J.; McDowell, Kyle D.

    2014-11-01

    Sandia National Laboratories has tested and evaluated a new infrasound sensor, the MB3a, manufactured by Seismo Wave. These infrasound sensors measure pressure output by a methodology developed by researchers at the French Alternative Energies and Atomic Energy Commission (CEA) and the technology was recently licensed to Seismo Wave for production and sales. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, dynamic range, seismic sensitivity, and self- calibration ability. The MB3a infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stan, Claudiu A.; Willmott, Philip R.; Stone, Howard A.

    Most experimental studies of cavitation in liquid water at negative pressures reported cavitation at tensions significantly smaller than those expected for homogeneous nucleation, suggesting that achievable tensions are limited by heterogeneous cavitation. We generated tension pulses with nanosecond rise times in water by reflecting cylindrical shock waves, produced by X-ray laser pulses, at the internal surface of drops of water. Depending on the X-ray pulse energy, a range of cavitation phenomena occurred, including the rupture and detachment, or spallation, of thin liquid layers at the surface of the drop. When spallation occurred, we evaluated that negative pressures below –100 MPamore » were reached in the drops. As a result, we model the negative pressures from shock reflection experiments using a nucleation-and-growth model that explains how rapid decompression could outrun heterogeneous cavitation in water, and enable the study of stretched water close to homogeneous cavitation pressures.« less

  1. Hybrid Feedforward-Feedback Noise Control Using Virtual Sensors

    NASA Technical Reports Server (NTRS)

    Bean, Jacob; Fuller, Chris; Schiller, Noah

    2016-01-01

    Several approaches to active noise control using virtual sensors are evaluated for eventual use in an active headrest. Specifically, adaptive feedforward, feedback, and hybrid control structures are compared. Each controller incorporates the traditional filtered-x least mean squares algorithm. The feedback controller is arranged in an internal model configuration to draw comparisons with standard feedforward control theory results. Simulation and experimental results are presented that illustrate each controllers ability to minimize the pressure at both physical and virtual microphone locations. The remote microphone technique is used to obtain pressure estimates at the virtual locations. It is shown that a hybrid controller offers performance benefits over the traditional feedforward and feedback controllers. Stability issues associated with feedback and hybrid controllers are also addressed. Experimental results show that 15-20 dB reduction in broadband disturbances can be achieved by minimizing the measured pressure, whereas 10-15 dB reduction is obtained when minimizing the estimated pressure at a virtual location.

  2. Investigating Premature Ignition of Thruster Pressure Cartridges by Mechanical Impact of Internal Components

    NASA Technical Reports Server (NTRS)

    Woods, Stephen S.; Saulsberry, Regor

    2010-01-01

    Pyrotechnic thruster pressure cartridges (TPCs) are used for aeroshell separation on a new NASA crew launch vehicle. The premature ignition concern was hypothesized based on the potential range of motion of the subassemblies, projected worst case accelerations, and the internal geometry that could subject propellant grains to mechanical impact sufficiently high for ignition. This possibility was investigated by fabricating a high-fidelity model of the suspected contact geometry, placing a representative amount of propellant in it, and impacting the propellant with a range of forces equivalent to and greater than the maximum possible during launch. Testing demonstrated that the likelihood of ignition is less than 1 in 1,000,000. The test apparatus, methodology, and results are described in this paper. Nondestructive evaluation ( NDE) during TPC acceptance testing indicated that internal assemblies moved during shock and vibration testing due to an internal bond anomaly. This caused concerns that the launch environment might produce the same movement and release propellant grains that might be prematurely ignited through impact or through electrostatic discharge (ESD) as grains vibrated against internal surfaces. Since a new lot could not be fabricated in time, a determination had to be made as to whether the lot was acceptable to fly. This paper discusses the analysis and impact testing used to address the potential impact issue and a separate paper addresses the ESD issue.

  3. [Implementation of the National Expert Standard Prophylaxis of Pressure Ulcers in nurse practise - a cost-benefit analysis].

    PubMed

    Wolke, R; Hennings, D; Scheu, P

    2007-06-01

    By developing evidence-based, national Expert Standards, agreed-upon by an association of nursing professionals, the German Care Science participates in the international discussion. Up to now, five National Expert Standards on relevant care-related topics have been developed and have been widely implemented in Care Practice. However, sufficient evaluations of these Expert Standards are still required, especially from an economic perspective. The following paper addresses this topic by performing a cost-benefit analysis for the National Expert Standard Prophylaxis of Pressure Ulcers. The authors demonstrate which costs are caused by the implementation of this National Expert Standard for a residential care agency providing services. The benefit of the implementation of the Expert Standard is then being compared to its cost for a period of three years. The evaluation concludes that, in consideration of opportunity costs, the introduction of the National Expert Standard Prophylaxis of Pressure Ulcers appears economically viable for the residential care agency only if the rate of pressure ulcers in the reference agency can be lowered at least by 26.48%. In this case, when exclusively considering direct benefits and direct costs, a positive impact of the implementation will be achieved.

  4. Posttest analysis of international standard problem 10 using RELAP4/MOD7. [PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, M.; Davis, C.B.; Peterson, A.C. Jr.

    RELAP4/MOD7, a best estimate computer code for the calculation of thermal and hydraulic phenomena in a nuclear reactor or related system, is the latest version in the RELAP4 code development series. This paper evaluates the capability of RELAP4/MOD7 to calculate refill/reflood phenomena. This evaluation uses the data of International Standard Problem 10, which is based on West Germany's KWU PKL refill/reflood experiment K9A. The PKL test facility represents a typical West German four-loop, 1300 MW pressurized water reactor (PWR) in reduced scale while maintaining prototypical volume-to-power ratio. The PKL facility was designed to specifically simulate the refill/reflood phase of amore » hypothetical loss-of-coolant accident (LOCA).« less

  5. Air Leakage and Air Transfer Between Garage and Living Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  6. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  7. Lack of validation of the Dixtal (DX 2020) upper arm blood pressure monitor, in oscillometric mode, for clinical use in an intensive care unit, according to the European Society of Hypertension-International Protocol revision 2010.

    PubMed

    Gothardo, Ana C L O; Savioli, Amanda F; Santos, Dayanna S; Lamas, José L T

    2013-08-01

    The aim of the study was to evaluate the accuracy of the oscillometric blood pressure section in the DX 2020 Dixtal multiparametric monitor in adults according to the European Society of Hypertension-International Protocol as revised in 2010 (ESH-IP 2010). The blood pressure was sequentially verified in 33 individuals admitted to an adult ICU (18 men, mean age 44 years) with a mercury column sphygmomanometer (two observers) and the DX 2020 test device (one supervisor). Ninety-nine pairs of differences were obtained. Data analysis followed the ESH-IP 2010 requirements. In the first requirement, the DX 2020 device failed in the validation study in the 5, 10, and 15 mmHg ranges. From the 99 pairs of differences, only 43/73, 69/87, and 81/96 were obtained for systolic blood pressure and 29/65, 56/81, and 71/93 were obtained for diastolic blood pressure. In the second requirement, at least 24 individuals should have, from their comparisons, two under 0-5 mmHg ranges, which was observed only with 16 individuals in the systolic and nine in the diastolic range. Moreover, at maximum, only three readings could have differences of more than 5 mmHg, and this was observed in 10 individuals in the systolic range and 17 individuals in the diastolic range. The DX 2020 automatic multiparametric monitor for blood pressure measurement has not been recommended for clinical use according to the ESH-IP 2010. It is important to highlight that this work refers only to a blood pressure measurement module and that the same conclusion cannot be drawn for its other functions.

  8. Potential for hypobaric storage as a phytosanitary treatment: mortality of Rhagoletis pomonella (Diptera: Tephritidae) in apples and effects on fruit quality.

    PubMed

    Hulasare, Rajshekhar; Payton, Mark E; Hallman, Guy J; Phillips, Thomas W

    2013-06-01

    The efficacy of low-oxygen atmospheres using low pressure, referred to as hypobaric conditions, to kill egg and third-instar Rhagoletis pomonella (Walsh) in apples was investigated. Infested apples were exposed to 3.33 and 6.67 kPa in glass jars at 25 and 30 degrees C for times ranging from 3 to 120 h. Probit analyses and lethal dose ratio tests were performed to determine differences in lethal time values. Eggs were more tolerant of low pressure compared with third-instar R. pomonella. Mortality of eggs and larvae increased with increase in time of exposure to low pressure and temperature. Lower pressures increased percent mortality of eggs, but these values were not significantly different at the pressures tested in this investigation. The LT99 for R. pomonella eggs at 3.33 kPa was 105.98 and 51.46 h, respectively, at 25 and 30 degrees C, which was a significant effect of the higher temperature on egg mortality. Investigation into consumer acceptance of low-pressure-treated apples was done with 'Red Delicious' and 'Golden Delicious'. Apples exposed to 3.33 kPa at 25 and 30 degrees C for 3 and 5 d were stored at 1 degrees C for 2 wk and presented to a sensory panel for evaluation. The panelists rated treated apples with untreated controls for external and internal appearance and taste. Golden Delicious apples were unaffected for all three sensory factors across both temperatures and exposure times. Although taste was unaffected for Red Delicious, the internal and external appearances deteriorated. Use of low pressure for disinfestation and preservation of apples is a potential nonchemical alternative to chemical fumigants such as methyl bromide and phosphine.

  9. Sociocultural pressures, thin-ideal internalization, self-objectification, and body dissatisfaction: could feminist beliefs be a moderating factor?

    PubMed

    Myers, Taryn A; Crowther, Janis H

    2007-09-01

    Theory and research suggest that sociocultural pressures, thin-ideal internalization, and self-objectification are associated with body dissatisfaction, while feminist beliefs may serve a protective function. This research examined thin-ideal internalization and self-objectification as mediators and feminist beliefs as a moderator in the relationship between sociocultural pressures to meet the thin-ideal and body dissatisfaction. Female undergraduate volunteers (N=195) completed self-report measures assessing sociocultural influences, feminist beliefs, thin-ideal internalization, self-objectification, and body dissatisfaction. Multisample structural equation modeling showed that feminist beliefs moderate the relationship between media awareness and thin-ideal internalization, but not the relationship between social influence and thin-ideal internalization. Research and clinical implications of these findings are discussed.

  10. Microclimate and development of pressure ulcers and superficial skin changes.

    PubMed

    Yusuf, Saldy; Okuwa, Mayumi; Shigeta, Yoshie; Dai, Misako; Iuchi, Terumi; Rahman, Sulaiman; Usman, Awaluddin; Kasim, Sukmawati; Sugama, Junko; Nakatani, Toshio; Sanada, Hiromi

    2015-02-01

    This study aims to evaluate the microclimate and development of pressure ulcers and superficial skin changes. A prospective cohort study was conducted in an acute care ward in Indonesia. Risk factors for pressure ulcers and superficial skin changes were identified based on the Bergstrom Braden conceptual model. Microclimate data were collected every 3 days for 15 days while the development of pressure ulcers and superficial skin changes was observed every day. Pressure ulcers and superficial skin changes were developed in 20 of the 71 participants. Total mean difference in skin temperature was higher for patients with pressure ulcers and superficial skin changes (0·9 ± 0·6°C) compared with controls (0·6 ± 0·8°C) (P = 0·071). Binary logistic regression predictor values for pressure ulcers and superficial skin changes were 0·111 for type of sheet and 0·347 for Braden Scale results. In conclusion, difference in skin temperature seems to be a predictor for pressure ulcer development and superficial skin changes, while synthetic fibre sheets are able to maintain a beneficial microclimate. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  11. APOL1 genetic variants are not associated with longitudinal blood pressure in young black adults.

    PubMed

    Chen, Teresa K; Estrella, Michelle M; Vittinghoff, Eric; Lin, Feng; Gutierrez, Orlando M; Kramer, Holly; Lewis, Cora E; Kopp, Jeffrey B; Allen, Norrina B; Winkler, Cheryl A; Bibbins-Domingo, Kirsten B; Peralta, Carmen A

    2017-10-01

    Whether APOL1 polymorphisms contribute to the excess risk of hypertension among blacks is unknown. To assess this we evaluated whether self-reported race and, in blacks, APOL1 risk variants (high-risk [2 risk alleles] versus low-risk [0-1 risk allele]) were associated with longitudinal blood pressure. Blood pressure trajectories were determined using linear mixed-effects (slope) and latent class models (5 distinct groups) during 25 years of follow-up in the Coronary Artery Risk Development in Young Adults Study. Associations of race and APOL1 genotypes with blood pressure change, separately, using linear mixed-effects and multinomial logistic regression models, adjusting for demographic, socioeconomic, and traditional hypertension risk factors, anti-hypertensive medication use, and kidney function were evaluated. Among 1700 whites and 1330 blacks (13% APOL1 high-risk, mean age 25 years; 46% male) mean mid-, ([systolic + diastolic blood pressure]/2), systolic, and diastolic blood pressures were 89, 110, and 69 mm Hg, respectively. One percent of participants used anti-hypertensive medications at baseline. Compared to whites, blacks, regardless of APOL1 genotype, had significantly greater increases in mid-blood pressure and were more likely to experience significantly increasing mid-blood pressure trajectories with adjusted relative risk ratios of 5.21 and 7.27 for moderate-increasing and elevated-increasing versus low-stable blood pressure, respectively. Among blacks, longitudinal mid-blood pressure changes and mid-blood pressure trajectory classification were similar by APOL1 risk status. Modeling systolic and diastolic blood pressure as outcomes yielded similar findings. From young adulthood to mid-life, blacks have greater blood pressure increases versus whites that are not fully explained by traditional risk factors. Thus APOL1 variants are not associated with longitudinal blood pressure in blacks. Copyright © 2017 International Society of Nephrology. All rights reserved.

  12. Evaluation of manual resuscitators used in ICUs in Brazil*

    PubMed Central

    Ortiz, Tatiana de Arruda; Forti, Germano; Volpe, Márcia Souza; Beraldo, Marcelo do Amaral; Amato, Marcelo Britto Passos; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2013-01-01

    OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and expiratory resistance of the patient valve; functioning of the pressure-limiting valve; and tidal volume (VT) generated when the one-handed and two-handed techniques were used. The tests were performed and analyzed in accordance with the American Society for Testing and Materials (ASTM) F920-93 criteria. RESULTS: Expiratory resistance was greater than 6 cmH2O . L−1 . s−1 in only one MR. The pressure-limiting valve, a feature of five of the MRs, opened at low pressures (< 17 cmH2O), and the maximal pressure was 32.0-55.9 cmH2O. Mean VT varied greatly among the MRs tested. The mean VT values generated with the one-handed technique were lower than the 600 mL recommended by the ASTM. In the situations studied, mean VT was generally lower from the Brazilian-made MRs that had a pressure-limiting valve. CONCLUSIONS: The resistances imposed by the patient valve met the ASTM criteria in all but one of the MRs tested. The pressure-limiting valves of the Brazilian-made MRs usually opened at low pressures, providing lower VT values in the situations studied, especially when the one-handed technique was used, suggesting that both hands should be used and that the pressure-limiting valve should be closed whenever possible. PMID:24310633

  13. Evaluation of proficiency in using different inhaler devices among intern doctors.

    PubMed

    Kshatriya, Ravish M; Khara, Nimit V; Paliwal, Rajiv P; Patel, Satish N

    2016-01-01

    Doctors may have deficiencies in the ability to use different inhalers, which in turn, can result in improper technique by the patients and poorly controlled asthma and chronic obstructive pulmonary disease (COPD). To evaluate intern doctors' proficiency in using various inhaler devices. Seventy interns were evaluated for their proficiency in using pressurized metered dose inhaler (pMDI), pMDI with spacer, rotahaler, turbuhaler, and nebulizer. A structured assessment sheet was scored for identification and preparation of device, administration, coordination, and skill of explanation on a scale of 0-5. Common errors such as failure to shake pMDI before use, inability to identify the empty device, inadequate breath holding, and failure to advise gargles after use were recorded. pMDI and pMDI with spacer were identified correctly by 89% and 79% of interns. Over 90% could identify rotahaler and nebulizer whereas only 9% could identify turbuhaler. 79% and 60% could prepare pMDI and pMDI with spacer appropriately. Nebulizer preparation was performed correctly by 79% and almost all interns could not prepare turbuhaler. Only one intern administered turbuhaler correctly. About half of the participants knew the correct co-ordination for pMDI and pMDI with spacer. Two interns showed proper co-ordination in using turbuhaler. None could provide correct explanation for turbuhaler usage; whereas 76% and 70% did it for nebulizer and rotahaler, respectively. Only 43% of interns remembered to shake pMDI before use. Proficiency in using different inhaler devices amongst interns is poor. It is essential to provide adequate training for inhaler devices usage to medical graduates for proper management of asthma and COPD patients by those future primary care physicians and specialists.

  14. Parental pressure and support toward Asian Americans' self-efficacy, outcome expectations, and interests in stereotypical occupations: Living up to parental expectations and internalized stereotyping as mediators.

    PubMed

    Shen, Frances C; Liao, Kelly Yu-Hsin; Abraham, W Todd; Weng, Chih-Yuan

    2014-04-01

    This study examined whether living up to parental expectations and internalized stereotyping (i.e., internalizing Asian American stereotypes) mediated the impact of parental pressure and support on occupational outcomes (i.e., self-efficacy, outcome expectations, and interests in stereotypical occupations) among 229 Asian American students from universities nationwide. Results indicated that living up to parental expectations and internalized stereotyping partially mediated the associations between parental pressure and these 3 occupational outcomes. In addition, living up to parental expectations fully mediated the associations between parental support and the 3 occupational outcomes, but internalized stereotyping did not. The results demonstrated the differential role of parental pressure and parental support as well as the mediating role of living up to parental expectations and internalized stereotyping in Asian Americans' occupational outcomes. Future research directions and clinical implications are discussed. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  15. Physical Training, Hemodynamic Parameters and Arterial Stiffness: Friends or Foes of the Hypertensive Patient?

    PubMed

    Iurciuc, Stela; Avram, Claudiu; Turi, Vladiana; Militaru, Anda; Avram, Adina; Cimpean, Anca Maria; Iurciuc, Mircea

    2016-01-01

    To evaluate the impact of physical training on central hemodynamic parameters and elasticity of large arteries in hypertensive patients. A total of 129 hypertensive patients were divided into two groups: group A followed lifestyle changes and physical training; and group B acted as a control group; seven parameters were recorded: Pulse wave velocity (PWVao), systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP), central aortic systolic blood pressure (SBPao), aortic diastolic blood pressure (DBPao), and central aortic pulse pressure (PPao). The difference between values at 4 months and baseline (Δ) were as follows: ΔPWVao was -1.02 m/s (p<0.001) versus 0.17 m/s (p=0.035), ΔSBPao was -9.6 mmHg (p=0.009) versus 1.6 mmHg (p=0.064), and ΔPPao was -6.8 mmHg (p<0.001) versus 3.2 mmHg, (p=0.029) in group A versus B, respectively. Exercise training improves SBP, PP, SBPao, PPao and may delay arterial ageing. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  16. 49 CFR 178.604 - Leakproofness test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... packaging must be restrained under water while an internal air pressure is applied; the method of restraint... accordance with appendix B of this part. (e) Pressure applied. An internal air pressure (gauge) must be applied to the packaging as indicated for the following packing groups: (1) Packing Group I: Not less than...

  17. 49 CFR 178.604 - Leakproofness test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... packaging must be restrained under water while an internal air pressure is applied; the method of restraint... accordance with appendix B of this part. (e) Pressure applied. An internal air pressure (gauge) must be applied to the packaging as indicated for the following packing groups: (1) Packing Group I: Not less than...

  18. 49 CFR 178.604 - Leakproofness test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... packaging must be restrained under water while an internal air pressure is applied; the method of restraint... accordance with appendix B of this part. (e) Pressure applied. An internal air pressure (gauge) must be applied to the packaging as indicated for the following packing groups: (1) Packing Group I: Not less than...

  19. Recommended Practices for Measurement of Gas Path Pressures and Temperatures for Performance Assessment of Aircraft Turbine Engines and Components (Les Methodes Recommandees pour la Mesure de la Pression et de la Temperature de la Veine Gazeuse en Vue de l’Evaluation des Performances des Turbines Aeronautiques et de leurs Composants

    DTIC Science & Technology

    1990-06-01

    reduction software , prior to converting all remaining test which requires internal compensation. T he r sidual effect is pressures to engineering units...Reduction Conversion of Millivolts to Engineering Units. Carrying out numerical integrations to obtain area and mass weighted averages for various...Performance Assessment of Aircraft Turbine Engines and Components (Les MWthodes Recommande’es pour la Mesure de la Pression et de ]a Temperature de la

  20. Effectiveness of Protected Areas in the Pan-Tropics and International Aid for Conservation

    NASA Astrophysics Data System (ADS)

    Kim, D. H.

    2015-12-01

    Protected areas are crucial for tropical forest conservation efforts. Estimation of the effectiveness of protected areas is thus important for evaluating the efficacy of forest conservation policies and priorities. However, comprehensive evaluation of the long-term effects of Protected Areas and international aid is lacking. However, with the recent availability of long-term, large-scale forest cover change data at 30-m resolution, it has become possible to address some of the issues surrounding the effectiveness of protected areas. To evaluate the effectiveness of Protected Areas in the pan-tropics and international aid for conservation, we use the 30m resolution data along with econometrics 1) to estimate avoided deforestation by PAs in the tropics during the 2000s, 2) estimate effects of international aid on avoided deforestation by PAs and 3) analyze the relationships between the socio-economic variables and increases in deforestation, avoided deforestation by PAs and effects of international aid. Our results show that protected areas avoided 83,500 ± 21,200 km2 of deforestation during the 2000s. Brazil showed the highest estimates of effects of international aid on the avoided deforestation of 22 m2/USD, which is about 50 times higher compared to Indonesia (0.5 m2/USD). The regression analysis between avoided deforestation, effects of international aid and socio-economic factors demonstrates that PAs have been relatively more effective in the countries where the deforestation pressures were increasing and that governance and forest change monitoring capacity may be important factors enhancing the efficacy of international aid. Our study presents the first pan-tropical analysis of the long-term evaluation of the effectiveness of protected areas, international aid and their regulating factors using spatially explicit fine resolution data. Our findings allow us to pinpoint where conservation initiatives and resource management are effectively practiced and to discover the link with socio-economic factors and their significance and underlying implications for the effectiveness of PAs.

  1. Rates, amounts, and determinants of ambulatory blood pressure monitoring claim reimbursements among Medicare beneficiaries.

    PubMed

    Kent, Shia T; Shimbo, Daichi; Huang, Lei; Diaz, Keith M; Viera, Anthony J; Kilgore, Meredith; Oparil, Suzanne; Muntner, Paul

    2014-12-01

    Ambulatory blood pressure monitoring (ABPM) can be used to identify white coat hypertension and guide hypertensive treatment. We determined the percentage of ABPM claims submitted between 2007 and 2010 that were reimbursed. Among 1970 Medicare beneficiaries with submitted claims, ABPM was reimbursed for 93.8% of claims that had an International Classification of Diseases, Ninth Revision, diagnosis code of 796.2 ("elevated blood pressure reading without diagnosis of hypertension") versus 28.5% of claims without this code. Among claims without an International Classification of Diseases, Ninth Revision, diagnosis code of 796.2 listed, those for the component (eg, recording, scanning analysis, physician review, reporting) versus full ABPM procedures and performed by institutional versus non-institutional providers were each more than two times as likely to be successfully reimbursed. Of the claims reimbursed, the median payment was $52.01 (25th-75th percentiles, $32.95-$64.98). In conclusion, educating providers on the ABPM claims reimbursement process and evaluation of Medicare reimbursement may increase the appropriate use of ABPM and improve patient care. Copyright © 2014 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  2. Composite laminated shells under internal pressure

    NASA Technical Reports Server (NTRS)

    Yuan, F. G.

    1992-01-01

    A theoretical study is conducted of the response of filament-wound composite shells under internal pressure; a system of sixth-order ordinary differential equations is obtained by means of the cylindrically anisotropic elasticity field equations and Lekhnitskii's (1963) stress functions. The general expressions for the stresses and displacements in the laminated composite shells under internal pressure are discussed. Attention is given to the influence of the degree of material anisotropy and fiber orientation on the axial and induced twisting deformation.

  3. 77 FR 16270 - Updated Aging Management Criteria for Reactor Vessel Internal Components of Pressurized Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0070] Updated Aging Management Criteria for Reactor Vessel Internal Components of Pressurized Water Reactors AGENCY: Nuclear Regulatory Commission. ACTION: Draft..., ``Updated Aging Management Criteria for PWR Reactor Vessel Internal Components.'' This draft LR-ISG revises...

  4. 77 FR 23513 - Updated Aging Management Criteria for Reactor Vessel Internal Components of Pressurized Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-19

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0070] Updated Aging Management Criteria for Reactor Vessel Internal Components of Pressurized Water Reactors AGENCY: Nuclear Regulatory Commission. ACTION: Draft...-ISG), LR-ISG-2011-04, ``Updated Aging Management Criteria for PWR Reactor Vessel Internal Components...

  5. 'It's a cultural expectation...' The pressure on medical trainees to work independently in clinical practice.

    PubMed

    Kennedy, Tara J T; Regehr, Glenn; Baker, G Ross; Lingard, Lorelei A

    2009-07-01

    Medical trainees demonstrate a reluctance to ask for help unless they believe it is absolutely necessary, a situation which could impact on the safety of patients. This study aimed to develop a theoretical exploration of the pressure on medical trainees to be independent and to generate theory-based approaches to the implications for patient safety of this pressure towards independent working. In Phase 1, 88 teaching team members from internal and emergency medicine were observed during clinical activities (216 hours), and 65 participants completed brief interviews. In Phase 2, 36 in-depth interviews were conducted using video vignettes. Data collection and analysis employed grounded theory methodology. Participants conceived that the pressure towards independence in clinical work originated in trainees' desire to lay claim to the identity of a doctor (as a member of a group of autonomous high achievers), and in organisational issues such as heavy workloads and constant evaluations. The identity and organisational issues related to the pressure towards independence were explored through the lenses of established theories from education and psychology. Consideration of Lave and Wenger's situated learning theory suggests that giving attention to the 'independent doctor' ideal, through measures such as involving trainees when their supervisors ask for help, could impact the safety of teaching team practice. Amalberti et al.'s migration model explains how pressures to maximise productivity and individual gain may cause teaching teams to migrate beyond the boundaries of safe practice and suggests that managing triggers (such as workload and high-stakes evaluations) for violations of safe practice might improve safety. Implementation and evaluation of these theory-based approaches to the safety of teaching team practice would contribute to a better understanding of the links between trainee independence and patient safety.

  6. iss042e236075

    NASA Image and Video Library

    2015-02-10

    ISS042E236075 (02/10/2015) --- Astronauts in space must exercise regularly to keep muscles from deteriorating. The busy schedule aboard the International Space Station has these regular periods worked in as NASA astronaut Terry Virts shows in this Tweet he sent out on Feb. 10, 2015 with the comment: "Periodic Fitness Evaluation- riding the bike with a heart rate monitor, EKG, and blood pressure machine hooked up".

  7. Vacuum boilers developed heating surfaces technic and economic efficiency evaluation

    NASA Astrophysics Data System (ADS)

    Slobodina, E. N.; Mikhailov, A. G.; Semenov, B. A.

    2018-01-01

    The vacuum boilers as manufacturing proto types application analysis was carried out, the possible directions for the heating surfaces development are identified with a view to improving the energy efficiency. Economic characteristics to evaluate the vacuum boilers application efficiency (Net Discounted Income (NDI), Internal Rate of Return (IRR), Profitability Index (PI) and Payback Period) are represented. The given type boilers application technic and economic efficiency criteria were established. NDI changing curves depending on the finning coefficient and operating pressure were obtained as a result of the conducted calculation studies.

  8. Effects of Pleurotomy on Respiratory Sequelae after Internal Mammary Artery Harvesting

    PubMed Central

    Iyem, Hikmet; Islamoglu, Fatih; Yagdi, Tahir; Sargin, Murat; Berber, Ozbek; Hamulu, Ahmet; Buket, Suat; Durmaz, Isa

    2006-01-01

    The preservation of pleural integrity during mammary artery harvesting may decrease atelectasis and pleural effusion during the postoperative period. We designed this retrospective study to evaluate the effects on postoperative pulmonary function of pleural integrity versus opened pleura, in patients who receive a left internal mammary artery graft. The study group consisted of 1,141 patients who underwent elective coronary artery bypass grafting. The patients were retrospectively evaluated and divided into 2 groups: those who underwent internal mammary artery harvesting with opened pleura (n=873) or with pleural integrity (n=268). To monitor pleural effusion and atelectasis, chest radiography was performed routinely 1 day before operation and on the 2nd, 5th, and 7th postoperative days. The preoperative, after extubation, and 1st postoperative day values of partial oxygen pressure (PaO2), partial carbon dioxide pressure (PaCO2), and oxygen (O2) saturation were recorded for comparison, as was the hematocrit. The mean age of the patients was 57.4 ± 8.81 years. There were no significant differences between the groups in mean values of PaO2, PaCO2, O2 saturation, and hematocrit after extubation or on the 1st postoperative day. Atelectasis on the 5th and 7th postoperative days, pleural effusion on the 2nd, 5th, and 7th days, and postoperative bleeding were significantly less in the group with preserved pleural integrity. We showed that preservation of pleural integrity during internal mammary artery harvesting decreases postoperative bleeding, pleural effusion, and atelectasis. We conclude that preservation of pleural integrity, when possible, can decrease these postoperative complications of coronary artery bypass grafting. PMID:16878610

  9. Creep-Rupture Behavior and Recrystallization in HR6W and Haynes Alloy 230 Cold-Bent Boiler Tubing for Ultrasupercritical (USC) Steam Boiler Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shingledecker, John P

    2007-01-01

    Creep-rupture experiments were conducted on HR6W and Haynes 230, candidate Ultrasupercritical (USC) alloys, tubes to evaluate the effects of cold-work and recrystallization during high-temperature service. These creep tests were performed by internally pressurizing cold-bent boiler tubes at 775 C for times up to 8000 hours. The bends were fabricated with cold-work levels beyond the current ASME Boiler and Pressure Vessel (ASME B&PV) Code Section I limits for austenitic stainless steels. Destructive metallographic evaluation of the crept tube bends was used to determine the effects of cold-work and the degree of recrystallization. The metallographic analysis combined with an evaluation of themore » creep and rupture data suggest that solid-solution strengthened nickel-based alloys can be fabricated for high-temperature service at USC conditions utilizing levels of cold-work higher than the current allowed levels for austenitic stainless steels.« less

  10. Influence of Internal DNA Pressure on Stability and Infectivity of Phage λ

    PubMed Central

    Bauer, D. W.; Evilevitch, A.

    2016-01-01

    Viruses must remain infectious while in harsh extracellular environments. An important aspect of viral particle stability for double-stranded DNA viruses is the energetically unfavorable state of the tightly confined DNA chain within the virus capsid creating pressures of tens of atmospheres. Here we study the influence of internal genome pressure on the thermal stability of viral particles. Using differential scanning calorimetry (DSC) to monitor genome loss upon heating, we find that internal pressure destabilizes the virion, resulting in a smaller activation energy barrier to trigger DNA release. These experiments are complemented by plaque assay and electron microscopy measurements to determine the influence of intra-capsid DNA pressure on the rates of viral infectivity loss. At higher temperatures (65 – 75 °C), failure to retain the packaged genome is the dominant mechanism of viral inactivation. Conversely, at lower temperatures (40 – 55 ºC), a separate inactivation mechanism dominates, which results in non-infectious particles that still retain their packaged DNA. Most significantly, both mechanisms of infectivity loss are directly influenced by internal DNA pressure, with higher pressure resulting in a more rapid rate of inactivation at all temperatures. PMID:26254570

  11. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.

    PubMed

    Portnoy, S; Yarnitzky, G; Yizhar, Z; Kristal, A; Oppenheim, U; Siev-Ner, I; Gefen, A

    2007-01-01

    Fitting of a prosthetic socket is a critical stage in the process of rehabilitation of a trans-tibial amputation (TTA) patient, since a misfit may cause pressure ulcers or a deep tissue injury (DTI: necrosis of the muscle flap under intact skin) in the residual limb. To date, prosthetic fitting typically depends on the subjective skills of the prosthetist, and is not supported by biomedical instrumentation that allows evaluation of the quality of fitting. Specifically, no technology is presently available to provide real-time continuous information on the internal distribution of mechanical stresses in the residual limb during fitting of the prosthesis, or while using it and this severely limits patient evaluations. In this study, a simplified yet clinically oriented patient-specific finite element (FE) model of the residual limb was developed for real-time stress analysis. For this purpose we employed a custom-made FE code that continuously calculates internal stresses in the residual limb, based on boundary conditions acquired in real-time from force sensors, located at the limb-prosthesis interface. Validation of the modeling system was accomplished by means of a synthetic phantom of the residual limb, which allowed simultaneous measurements of interface pressures and internal stresses. Human studies were conducted subsequently in five TTA patients. The dimensions of bones and soft tissues were obtained from X-rays of the residual limb of each patient. An indentation test was performed in order to obtain the effective elastic modulus of the soft tissues of the residual limb. Seven force sensors were placed between the residual limb and the prosthetic liner, and subjects walked on a treadmill during analysis. Generally, stresses under the shinbones were approximately threefold higher than stresses at the soft tissues behind the bones. Usage of a thigh corset decreased the stresses in the residual limb during gait by approximately 80%. Also, the stresses calculated during the trial of a subject who complained about pain and discomfort were the highest, confirming that his socket was not adequately fitted. We conclude that real-time patient-specific FE analysis of internal stresses in deep soft tissues of the residual limb in TTA patients is feasible. This method is promising for improving the fitting of prostheses in the clinical setting and for protecting the residual limb from pressure ulcers and DTI.

  12. A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.

    PubMed

    Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J

    2017-10-01

    The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Trial of validation of two devices for self-measurement of blood pressure according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C.

    PubMed

    Cotte, Uwe V; Faltenbacher, Verena H; von Willich, Werner; Bogner, Johannes R

    2008-02-01

    Two devices for self-measurement of blood pressure, one at the upper arm (Citizen CH-432B) and one at the wrist (Citizen CH-656C), were evaluated according to the International Protocol of the European Society of Hypertension. The International Protocol is divided into two phases: the first phase is performed on 15 selected participants with five participants in three different blood pressure ranges. If the devices passed this phase, 18 additional participants selected on the basis of the same criteria as in phase 1 were included. Two skilled observers performed the following blood pressure measurements: five measurements were performed with the mercury standard alternating with four measurements with each of the test devices per participant. The first measurement result from each device instrument was not included in the analysis. The difference between the blood pressure value given by the devices and that obtained by the two observers (mean of the two observers) was calculated for each pair of measurements and classified into three categories (within 5, 10 and 15 mmHg). The results were compared to the pass criteria established by the European Society of Hypertension. Afterwards the number of measurement differences falling within 5 mmHg was determined for every person. At least 22 of the 33 participants should have two of their three comparisons within 5 mmHg and there should be a maximum of three participants without a measurement difference within the 5 mmHg range. Both tested devices passed the first phase of the validation process by exceeding the required number of comparisons falling within the 5, 10 and 15 mmHg error zones. Even the second phase confirmed the validation criteria with average differences between the device and the mercury sphygmomanometer of 0.7+/-4.4 and -3.6+/-4.0 mmHg for systolic blood pressure and diastolic blood pressure, respectively, for the Citizen CH-432B device and -0.7+/-6.0 and -1.2+/-4.5 mmHg for the Citizen CH-656C device. Phase 2 contains furthermore an individual analysis of the 33 participants, the requirements of which were also fulfilled by both devices. The Citizen CH-432B and the Citizen CH-656C devices pass the validation recommendations of the International Protocol. They can be recommended for clinical use.

  14. Evaluation of Series T22 Wet Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2017-01-01

    Several types of advanced wet tantalum capacitors, and series T22 in particular, are designed without internal Teflon sealing that is used for military grade, CLR style capacitors. This raises concerns regarding hermeticity of the single seal parts and their capability to withstand high internal gas pressures that might develop during operation in space. To address these issues, T22 series capacitors rated to 50 V and 125 V were subjected to highly accelerated life testing (HALT) at 125 C and rated voltage and step stress random vibration testing (RVT). To simulate conditions of storage or operation under increased internal gas pressure, the parts were stored at temperature of 150 C for 2500 hr (HTS150). Electrical characteristics of the parts were measured through the storage testing and the hermeticity leak rate was tested before and after HTS150. To assess thermo-mechanical robustness of the part, capacitors were manually soldered onto printed wired boards (PWB) and stressed by 1000 temperature cycles between -55 C and +125 C. The effect of temperature cycling was assessed by additional HALT at different temperatures. Results show that T22 series capacitors have robust design and can satisfy requirements for space applications.

  15. Score reliability and factor similarity of the Sociocultural Attitudes Towards Appearance Questionnaire-3 (SATAQ-3) among four ethnic groups

    PubMed Central

    2013-01-01

    Background This study evaluated the score reliability and equivalence of factor structure of the Sociocultural Attitudes towards Appearance Questionnaire-3 (SATAQ-3) [1] in a sample of female college students from the four largest ethnic groups in the USA. Methods Participants were 1245 women who self-identified as European American/White (n = 543), African American/Black (n = 137), Asian American (n = 317), or Latina/Hispanic (n = 248). All completed the SATAQ-3 and a demographic questionnaire. To test the factor similarity and score reliability across groups, we used exploratory factor analysis and calculated Cronbach’s alphas (respectively). Results Score reliability was high for all groups. Tests of factor equivalence suggested that the four pre-established factors of the SATAQ-3 (i.e., knowledge, perceived pressure, thin-ideal internalization, athletic-ideal internalization) were similar for women of all ethnic groups. Only two items (20 and 27) did not consistently load on the previously identified scale across all four groups. When scored, African Americans reported significantly less perceived pressure and internalization than all other groups. Conclusions Results support the use of the SATAQ-3 in female college students of these four ethnicities. PMID:24999395

  16. Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo

    2014-02-01

    The objective of this study was to determine the accuracy of the A&D BP UA-651 device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Device evaluation was carried out in 33 patients. The mean age of the patients was 48.3±15.5 years, the mean systolic BP was 138.3±24.9 mmHg (range 90-180), the mean diastolic BP was 88.3±13.8 mmHg (range 60-108), and the mean arm circumference was 28.6±3.4 cm (range 23-36). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device underestimated the systolic BP by 0.4±4.4 mmHg and diastolic BP by 1.3±3.5 mmHg. The device-observer discrepancies were unrelated to patients' clinical characteristics. These data show that the A&D BP UA-651 device fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  17. Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population.

    PubMed

    Grover-Páez, Fernando; Cardona-Muñoz, Ernesto G; Cardona-Müller, David; Guzmán-Saldívar, Víctor H; Rodríguez-De la Cerda, Mariana; Jiménez-Cázarez, Mayra B; Totsuka-Sutto, Sylvia E; Alanis-Sánchez, Guillermo A; Ramos-Becerra, Carlos G

    2017-12-01

    The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.

  18. Estimation of turgor pressure through comparison between single plant cell and pressurized shell mechanics

    NASA Astrophysics Data System (ADS)

    Durand-Smet, P.; Gauquelin, E.; Chastrette, N.; Boudaoud, A.; Asnacios, A.

    2017-10-01

    While plant growth is well known to rely on turgor pressure, it is challenging to quantify the contribution of turgor pressure to plant cell rheology. Here we used a custom-made micro-rheometer to quantify the viscoelastic behavior of isolated plant cells while varying their internal turgor pressure. To get insight into how plant cells adapt their internal pressure to the osmolarity of their medium, we compared the mechanical behavior of single plant cells to that of a simple, passive, pressurized shell: a soccer ball. While both systems exhibited the same qualitative behavior, a simple mechanical model allowed us to quantify turgor pressure regulation at the single cell scale.

  19. Investigating Premature Ignition of Thruster Pressure Cartridges by Vibration-Induced Electrostatic Discharge

    NASA Technical Reports Server (NTRS)

    Woods, Stephen S.; Saulsberry, Regor

    2010-01-01

    Pyrotechnic thruster pressure cartridges (TPCs) are used for aeroshell separation on a new NASA crew launch vehicle. Nondestructive evaluation (NDE) during TPC acceptance testing indicated that internal assemblies moved during shock and vibration testing due to an internal bond anomaly. This caused concerns that the launch environment might produce the same movement and release propellant grains that might be prematurely ignited through impact or through electrostatic discharge (ESD) as grains vibrated against internal surfaces. Since a new lot could not be fabricated in time, a determination had to be made as to whether the lot was acceptable to fly. This paper discusses the ESD evaluation and a separate paper addresses the impact problem. A challenge to straight forward assessment existed due to the unavailability of triboelectric data characterizing the static charging characteristics of the propellants within the TPC. The approach examined the physical limitations for charge buildup within the TPC system geometry and evaluated it for discharge under simulated vibrations used to qualify components for launch. A facsimile TPC was fabricated using SS 301 for the case and surrogate worst case materials for the propellants based on triboelectric data. System discharge behavior was evaluated by applying high voltage to the point of discharge in air and by placing worst case charge accumulations within the facsimile TPC and forcing discharge. The facsimile TPC contained simulated propellant grains and lycopodium, a well characterized indicator for static discharge in dust explosions, and was subjected to accelerations equivalent to the maximum accelerations possible during launch. The magnitude of charge generated within the facsimile TPC system was demonstrated to lie in a range of 100 to 10,000 times smaller than the spark energies measured to ignite propellant grains in industry standard discharge tests. The test apparatus, methodology, and results are described in this paper.

  20. Secondary Prevention of Cardiovascular Disease in Patients With Type 2 Diabetes Mellitus: International Insights From the TECOS Trial (Trial Evaluating Cardiovascular Outcomes With Sitagliptin).

    PubMed

    Pagidipati, Neha J; Navar, Ann Marie; Pieper, Karen S; Green, Jennifer B; Bethel, M Angelyn; Armstrong, Paul W; Josse, Robert G; McGuire, Darren K; Lokhnygina, Yuliya; Cornel, Jan H; Halvorsen, Sigrun; Strandberg, Timo E; Delibasi, Tuncay; Holman, Rury R; Peterson, Eric D

    2017-09-26

    Intensive risk factor modification significantly improves outcomes for patients with diabetes mellitus and cardiovascular disease. However, the degree to which secondary prevention treatment goals are achieved in international clinical practice is unknown. Attainment of 5 secondary prevention parameters-aspirin use, lipid control (low-density lipoprotein cholesterol <70 mg/dL or statin therapy), blood pressure control (<140 mm Hg systolic, <90 mm Hg diastolic), angiotensin-converting enzyme inhibitor or angiotensin receptor blocker use, and nonsmoking status-was evaluated among 13 616 patients from 38 countries with diabetes mellitus and known cardiovascular disease at entry into TECOS (Trial Evaluating Cardiovascular Outcomes With Sitagliptin). Logistic regression was used to evaluate the association between individual and regional factors and secondary prevention achievement at baseline. Cox proportional hazards regression analysis was used to determine the association between baseline secondary prevention achievement and cardiovascular death, myocardial infarction, or stroke. Overall, 29.9% of patients with diabetes mellitus and cardiovascular disease achieved all 5 secondary prevention parameters at baseline, although 71.8% achieved at least 4 parameters. North America had the highest proportion (41.2%), whereas Western Europe, Eastern Europe, and Latin America had proportions of ≈25%. Individually, blood pressure control (57.9%) had the lowest overall attainment, whereas nonsmoking status had the highest (89%). Over a median 3.0 years of follow-up, a higher baseline secondary prevention score was associated with improved outcomes in a step-wise graded relationship (adjusted hazard ratio, 0.60; 95% confidence interval, 0.47-0.77 for those patients achieving all 5 measures versus those achieving ≤2). In an international trial population, significant opportunities exist to improve the quality of cardiovascular secondary prevention care among patients with diabetes mellitus and cardiovascular disease, which in turn could lead to reduced risk of downstream cardiovascular events. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00790205. © 2017 American Heart Association, Inc.

  1. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  2. Reduced pressure for fewer pressure ulcers: can real-time feedback of interface pressure optimise repositioning in bed?

    PubMed

    Gunningberg, Lena; Carli, Cheryl

    2016-10-01

    The aim of this study was to (i) describe registered nurses' and assistant nurses' repositioning skills with regard to their existing attitudes to and theoretical knowledge of pressure ulcer (PU) prevention, and (ii) evaluate if the continuous bedside pressure mapping (CBPM) system provides staff with a pedagogic tool to optimise repositioning. A quantitative study was performed using a descriptive, comparative design. Registered nurses (n = 19) and assistant nurses (n = 33) worked in pairs, and were instructed to place two volunteers (aged over 70 years) in the best pressure-reducing position (lateral and supine), first without viewing the CBPM monitor and then again after feedback. In total, 240 positionings were conducted. The results show that for the same person with the same available pressure-reducing equipment, the peak pressure varied considerably between nursing pairs. Reducing pressure in the lateral position appeared to be the most challenging. Peak pressures were significantly reduced, based on visual feedback from the CBPM monitor. The number of preventive interventions also increased, as well as patients' comfort. For the nurses as a group, the knowledge score was 59·7% and the attitude score was 88·8%. Real-time visual feedback of pressure points appears to provide another dimension to complement decision making with respect to PU prevention. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  3. A Wireless Pressure Sensor Integrated with a Biodegradable Polymer Stent for Biomedical Applications

    PubMed Central

    Park, Jongsung; Kim, Ji-Kwan; Patil, Swati J.; Park, Jun-Kyu; Park, SuA; Lee, Dong-Weon

    2016-01-01

    This paper describes the fabrication and characterization of a wireless pressure sensor for smart stent applications. The micromachined pressure sensor has an area of 3.13 × 3.16 mm2 and is fabricated with a photosensitive SU-8 polymer. The wireless pressure sensor comprises a resonant circuit and can be used without the use of an internal power source. The capacitance variations caused by changes in the intravascular pressure shift the resonance frequency of the sensor. This change can be detected using an external antenna, thus enabling the measurement of the pressure changes inside a tube with a simple external circuit. The wireless pressure sensor is capable of measuring pressure from 0 mmHg to 230 mmHg, with a sensitivity of 0.043 MHz/mmHg. The biocompatibility of the pressure sensor was evaluated using cardiac cells isolated from neonatal rat ventricular myocytes. After inserting a metal stent integrated with the pressure sensor into a cardiovascular vessel of an animal, medical systems such as X-ray were employed to consistently monitor the condition of the blood vessel. No abnormality was found in the animal blood vessel for approximately one month. Furthermore, a biodegradable polymer (polycaprolactone) stent was fabricated with a 3D printer. The polymer stent exhibits better sensitivity degradation of the pressure sensor compared to the metal stent. PMID:27271619

  4. A Wireless Pressure Sensor Integrated with a Biodegradable Polymer Stent for Biomedical Applications.

    PubMed

    Park, Jongsung; Kim, Ji-Kwan; Patil, Swati J; Park, Jun-Kyu; Park, SuA; Lee, Dong-Weon

    2016-06-02

    This paper describes the fabrication and characterization of a wireless pressure sensor for smart stent applications. The micromachined pressure sensor has an area of 3.13 × 3.16 mm² and is fabricated with a photosensitive SU-8 polymer. The wireless pressure sensor comprises a resonant circuit and can be used without the use of an internal power source. The capacitance variations caused by changes in the intravascular pressure shift the resonance frequency of the sensor. This change can be detected using an external antenna, thus enabling the measurement of the pressure changes inside a tube with a simple external circuit. The wireless pressure sensor is capable of measuring pressure from 0 mmHg to 230 mmHg, with a sensitivity of 0.043 MHz/mmHg. The biocompatibility of the pressure sensor was evaluated using cardiac cells isolated from neonatal rat ventricular myocytes. After inserting a metal stent integrated with the pressure sensor into a cardiovascular vessel of an animal, medical systems such as X-ray were employed to consistently monitor the condition of the blood vessel. No abnormality was found in the animal blood vessel for approximately one month. Furthermore, a biodegradable polymer (polycaprolactone) stent was fabricated with a 3D printer. The polymer stent exhibits better sensitivity degradation of the pressure sensor compared to the metal stent.

  5. SOP: physical examination and laboratory testing for men with erectile dysfunction.

    PubMed

    Ghanem, Hussein M; Salonia, Andrea; Martin-Morales, Antonio

    2013-01-01

    Physical examination and laboratory evaluation of men with erectile dysfunction (ED) are opportunities to identify potentially life-threatening etiologies and comorbid conditions. To review genital anatomy, identify any physical abnormalities, assess for comorbid conditions, and reveal significant risk factors for ED. Expert opinion was based on evidence-based medical literature and consensus discussions between members of this International Society for Sexual Medicine (ISSM) standards committee. For men with ED, a general examination including blood pressure and pulse measurements and a focused genital exam are advised. Fasting blood sugar, serum total testosterone, prolactin levels, and a lipid profile may reveal significant comorbid conditions. Though physical examination and laboratory evaluation of most men with ED may not reveal the exact diagnosis, these opportunities to identify critical comorbid conditions should not be missed. © 2012 International Society for Sexual Medicine.

  6. Liquid hydrogen turbopump rapid start program. [thermal preconditioning using coatings

    NASA Technical Reports Server (NTRS)

    Wong, G. S.

    1973-01-01

    This program was to analyze, test, and evaluate methods of achieving rapid-start of a liquid hydrogen feed system (inlet duct and turbopump) using a minimum of thermal preconditioning time and propellant. The program was divided into four tasks. Task 1 includes analytical studies of the testing conducted in the other three tasks. Task 2 describes the results from laboratory testing of coating samples and the successful adherence of a KX-635 coating to the internal surfaces of the feed system tested in Task 4. Task 3 presents results of testing an uncoated feed system. Tank pressure was varied to determine the effect of flowrate on preconditioning. The discharge volume and the discharge pressure which initiates opening of the discharge valve were varied to determine the effect on deadhead (no through-flow) start transients. Task 4 describes results of testing a similar, internally coated feed system and illustrates the savings in preconditioning time and propellant resulting from the coatings.

  7. Probabilistic analysis of a materially nonlinear structure

    NASA Technical Reports Server (NTRS)

    Millwater, H. R.; Wu, Y.-T.; Fossum, A. F.

    1990-01-01

    A probabilistic finite element program is used to perform probabilistic analysis of a materially nonlinear structure. The program used in this study is NESSUS (Numerical Evaluation of Stochastic Structure Under Stress), under development at Southwest Research Institute. The cumulative distribution function (CDF) of the radial stress of a thick-walled cylinder under internal pressure is computed and compared with the analytical solution. In addition, sensitivity factors showing the relative importance of the input random variables are calculated. Significant plasticity is present in this problem and has a pronounced effect on the probabilistic results. The random input variables are the material yield stress and internal pressure with Weibull and normal distributions, respectively. The results verify the ability of NESSUS to compute the CDF and sensitivity factors of a materially nonlinear structure. In addition, the ability of the Advanced Mean Value (AMV) procedure to assess the probabilistic behavior of structures which exhibit a highly nonlinear response is shown. Thus, the AMV procedure can be applied with confidence to other structures which exhibit nonlinear behavior.

  8. Hypertonic/Hyperoncotic Resuscitation from Shock: Reduced Volume Requirement and Lower Intracranial Pressure

    DTIC Science & Technology

    1989-10-01

    in Dogs with Hemorrhagic Shock and an Intracranial Mass. Seventh International Symposium on Intracranial Pressure and Brain Injury , Ann Arbor, Michigan...with Hemorrhagic Shock and an Intracranial Mass. Seventh International Symposium on Intracranial Pressure and Brain Injury . Intracranial Pressure VII...and MCI US groups. Discussion: Following this severe insult a iETTiFMT3-a clinical head injury combined wit6i hemorrha Ic shock, a cobntnc/h rcctc

  9. Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats.

    PubMed

    Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki

    2016-03-01

    Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.

  10. Validation of the Beneware model ABP-021 ambulatory blood pressure monitor according to the revised 2010 European Society of hypertension international protocol.

    PubMed

    Pereira, Telmo; Guimarães, João

    2018-06-11

    This study aimed to evaluate the accuracy of the Beneware model ABP-021 oscillometric blood pressure monitor in the general population according to the European Society of Hypertension International Protocol (ESH-IP). The accuracy of the device was assessed in relation to various clinical variables, including age, sex, BMI, and arm circumference. Thirty-three individuals (18 men and 15 women), with a mean age of 36±14 years (age range: 20-68 years), were studied according to the recommendations of the ESH-IP. Sequential same-arm blood pressure measurements were performed, alternating between a mercury standard and the automatic device. The differences among the test-control measurements were assessed and divided into categorization zones of 5, 10, and 15 mmHg discrepancy. The device complied with the quality requirements of the ESH-IP. The device-observer disagreement was -1.2±4.7 mmHg for systolic blood pressure (SBP) and -1.7±4.3 mmHg for diastolic blood pressure (DBP). The device produced 77, 93, and 98 measurements, respectively, within the 5, 10, and 15 mmHg discrepancy limits for SBP. For DBP, 80, 97, and 99 measurements were observed within the 5, 10, and 15 mmHg discrepancy limits. The number of participants with two or three of the device-observer differences within 5 mmHg was 26 for SBP and 29 for DBP, whereas there were only two participants with no device-observer differences within 5 mmHg for DBP. These data show that the Beneware model ABP-021 monitor meets the requirements of the ESH-IP, in static conditions, indicating its suitability for measuring blood pressure in the general adult population.

  11. On the importance of 3D, geometrically accurate, and subject-specific finite element analysis for evaluation of in-vivo soft tissue loads.

    PubMed

    Moerman, Kevin M; van Vijven, Marc; Solis, Leandro R; van Haaften, Eline E; Loenen, Arjan C Y; Mushahwar, Vivian K; Oomens, Cees W J

    2017-04-01

    Pressure ulcers are a type of local soft tissue injury due to sustained mechanical loading and remain a common issue in patient care. People with spinal cord injury (SCI) are especially at risk of pressure ulcers due to impaired mobility and sensory perception. The development of load improving support structures relies on realistic tissue load evaluation e.g. using finite element analysis (FEA). FEA requires realistic subject-specific mechanical properties and geometries. This study focuses on the effect of geometry. MRI is used for the creation of geometrically accurate models of the human buttock for three able-bodied volunteers and three volunteers with SCI. The effect of geometry on observed internal tissue deformations for each subject is studied by comparing FEA findings for equivalent loading conditions. The large variations found between subjects confirms the importance of subject-specific FEA.

  12. The Role of Internalized Stereotyping, Parental Pressure, and Parental Support on Asian Americans' Choice of College Major

    ERIC Educational Resources Information Center

    Shen, Frances C.

    2015-01-01

    The author explored the relationship between internalized stereotyping, parental pressure, and parental support on major choices among 315 Asian American undergraduate and graduate students. Results indicated that parental support, but not parental pressure, toward certain majors was associated with more stereotypical major choices. In addition,…

  13. Development of a Novel Translational Model of Vibration Injury to the Spine to Study Acute Injury in Vivo

    DTIC Science & Technology

    2011-10-01

    internal pressure data were collected at 500 Hz. In addition, for the ST1 tests only, positional data were collected using the Optotrak at 200 Hz...Internal pressure was measured during experiments using a rectal pressure probe. Optotrak position data were measured during ST1 using markers on

  14. Hemodialysis-related headache.

    PubMed

    Sav, Murat Yusuf; Sav, Tansu; Senocak, Elif; Sav, Nadide Melike

    2014-10-01

    Headache is one of the most frequently encountered neurological symptoms during hemodialysis. According to International Classification of Headache criteria dialysis-related headache was defined as the headache occurring during hemodialysis with no specific characteristic. It resolves spontaneously within 72 hours after the hemodialysis session ends. There are few studies in the literature investigating the clinical features of dialysis headache. The pathophysiology of hemodialysis-related headache is not known, but various triggering factors have been identified, including changes in blood pressure, serum sodium and magnesium levels during hemodialysis sessions, caffeine deprivation and stress. The aim of this article is to evaluate and analyze features of headache in patients undergoing hemodialysis. © 2014 International Society for Hemodialysis.

  15. A Human Factors Evaluation of a Methodology for Pressurized Crew Module Acceptability for Zero-Gravity Ingress of Spacecraft

    NASA Technical Reports Server (NTRS)

    Sanchez, Merri J.

    2000-01-01

    This project aimed to develop a methodology for evaluating performance and acceptability characteristics of the pressurized crew module volume suitability for zero-gravity (g) ingress of a spacecraft and to evaluate the operational acceptability of the NASA crew return vehicle (CRV) for zero-g ingress of astronaut crew, volume for crew tasks, and general crew module and seat layout. No standard or methodology has been established for evaluating volume acceptability in human spaceflight vehicles. Volume affects astronauts'ability to ingress and egress the vehicle, and to maneuver in and perform critical operational tasks inside the vehicle. Much research has been conducted on aircraft ingress, egress, and rescue in order to establish military and civil aircraft standards. However, due to the extremely limited number of human-rated spacecraft, this topic has been un-addressed. The NASA CRV was used for this study. The prototype vehicle can return a 7-member crew from the International Space Station in an emergency. The vehicle's internal arrangement must be designed to facilitate rapid zero-g ingress, zero-g maneuverability, ease of one-g egress and rescue, and ease of operational tasks in multiple acceleration environments. A full-scale crew module mockup was built and outfitted with representative adjustable seats, crew equipment, and a volumetrically equivalent hatch. Human factors testing was conducted in three acceleration environments using ground-based facilities and the KC-135 aircraft. Performance and acceptability measurements were collected. Data analysis was conducted using analysis of variance and nonparametric techniques.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rempe, Joy; Farmer, Mitchell; Corradini, Michael

    The Three Mile Island Unit 2 (TMI-2) accident, which occurred on March 28, 1979, led industry and regulators to enhance strategies to protect against severe accidents in commercial nuclear power plants. Investigations in the years after the accident concluded that at least 45% of the core had melted and that nearly 19 tonnes of the core material had relocated to the lower head. Postaccident examinations indicate that about half of that material formed a solid layer near the lower head and above it was a layer of fragmented rubble. As discussed in this paper, numerous insights related to pressurized watermore » reactor accident progression were gained from postaccident evaluations of debris, reactor pressure vessel (RPV) specimens, and nozzles taken from the RPV. In addition, information gleaned from TMI-2 specimen evaluations and available data from plant instrumentation were used to improve severe accident simulation models that form the technical basis for reactor safety evaluations. Finally, the TMI-2 accident led the nuclear community to dedicate considerable effort toward understanding severe accident phenomenology as well as the potential for containment failure. Because available data suggest that significant amounts of fuel heated to temperatures near melting, the events at Fukushima Daiichi Units 1, 2, and 3 offer an unexpected opportunity to gain similar understanding about boiling water reactor accident progression. To increase the international benefit from such an endeavor, we recommend that an international effort be initiated to (a) prioritize data needs; (b) identify techniques, samples, and sample evaluations needed to address each information need; and (c) help finance acquisition of the required data and conduct of the analyses.« less

  17. Evaluation of a High Pressure Proportional Counter for the Detection of Radioactive Noble Gases

    DTIC Science & Technology

    1987-01-01

    Multiplication Curves Compared to Reconstructed Literature Curves .. .. ............ .81 6.4 Resolution .... . .. ......................... .... 90 v Figure...with 57 ~/57 energy resolution to 12% fwhm for Co photopeaks (-122 keV),sing argon fill gas at fifty atmospheres. Subsequent effects 0f a contami- nant...internal gas proportional counters for measuring low-level environmental radionuclides, resolutions to 27% fwhm and intrinsic efficiencies to 3 75

  18. Costing nursing education programs. It's as easy as 1-2-3.

    PubMed

    Fisher, M L; Hume, R; Emerick, R

    1998-01-01

    Staff development departments are pressured to reveal the costs of their educational programs and to compete with outside vendors for programming. The process of implementing a spreadsheet template for costing out staff development programs is described. The template is easy to use and supports "what if" analysis. This model allows educators to evaluate cost implications of curricular decisions and to better negotiate with internal and external customers.

  19. Evaluation of a Composite Sandwich Fuselage Side Panel with Damage and Subjected to Internal Pressure

    NASA Technical Reports Server (NTRS)

    Rouse, Marshall; Ambur, Damodar R.; Bodine, Jerry; Dopker, Bernhard

    1997-01-01

    The results from an experimental and analytical study of a composite sandwich fuselage side panel for a transport aircraft are presented. The panel has two window cutouts and three frames, and has been evaluated with internal pressure loads that generate biaxial tension loading conditions. Design limit load and design ultimate load tests have been performed on the graphite-epoxy sandwich panel with the middle frame removed to demonstrate the suitability of this two-frame design for supporting the prescribed biaxial loading conditions with twice the initial frame spacing of 20 inches. The two-frame panel was damaged by cutting a notch that originates at the edge of a cutout and extends in the panel hoop direction through the window-belt area. This panel with a notch was tested in a combined-load condition to demonstrate the structural damage tolerance at the design limit load condition. The two panel configurations successfully satisfied all design load requirements in the experimental part of the study, and the three-frame and two-frame panel responses are fully explained by the analysis results. The results of this study suggest that there is potential for using sandwich structural concepts with greater than the usual 20-in.-wide frame spacing to further reduce aircraft fuselage structural weight.

  20. Evaluation of SHM system produced by additive manufacturing via acoustic emission and other NDT methods.

    PubMed

    Strantza, Maria; Aggelis, Dimitrios G; de Baere, Dieter; Guillaume, Patrick; van Hemelrijck, Danny

    2015-10-21

    During the last decades, structural health monitoring (SHM) systems are used in order to detect damage in structures. We have developed a novel structural health monitoring approach, the so-called "effective structural health monitoring" (eSHM) system. The current SHM system is incorporated into a metallic structure by means of additive manufacturing (AM) and has the possibility to advance life safety and reduce direct operative costs. It operates based on a network of capillaries that are integrated into an AM structure. The internal pressure of the capillaries is continuously monitored by a pressure sensor. When a crack nucleates and reaches the capillary, the internal pressure changes signifying the existence of the flaw. The main objective of this paper is to evaluate the crack detection capacity of the eSHM system and crack location accuracy by means of various non-destructive testing (NDT) techniques. During this study, detailed acoustic emission (AE) analysis was applied in AM materials for the first time in order to investigate if phenomena like the Kaiser effect and waveform parameters used in conventional metals can offer valuable insight into the damage accumulation of the AM structure as well. Liquid penetrant inspection, eddy current and radiography were also used in order to confirm the fatigue damage and indicate the damage location on un-notched four-point bending AM metallic specimens with an integrated eSHM system. It is shown that the eSHM system in combination with NDT can provide correct information on the damage condition of additive manufactured metals.

  1. Evaluation of SHM System Produced by Additive Manufacturing via Acoustic Emission and Other NDT Methods

    PubMed Central

    Strantza, Maria; Aggelis, Dimitrios G.; de Baere, Dieter; Guillaume, Patrick; van Hemelrijck, Danny

    2015-01-01

    During the last decades, structural health monitoring (SHM) systems are used in order to detect damage in structures. We have developed a novel structural health monitoring approach, the so-called “effective structural health monitoring” (eSHM) system. The current SHM system is incorporated into a metallic structure by means of additive manufacturing (AM) and has the possibility to advance life safety and reduce direct operative costs. It operates based on a network of capillaries that are integrated into an AM structure. The internal pressure of the capillaries is continuously monitored by a pressure sensor. When a crack nucleates and reaches the capillary, the internal pressure changes signifying the existence of the flaw. The main objective of this paper is to evaluate the crack detection capacity of the eSHM system and crack location accuracy by means of various non-destructive testing (NDT) techniques. During this study, detailed acoustic emission (AE) analysis was applied in AM materials for the first time in order to investigate if phenomena like the Kaiser effect and waveform parameters used in conventional metals can offer valuable insight into the damage accumulation of the AM structure as well. Liquid penetrant inspection, eddy current and radiography were also used in order to confirm the fatigue damage and indicate the damage location on un-notched four-point bending AM metallic specimens with an integrated eSHM system. It is shown that the eSHM system in combination with NDT can provide correct information on the damage condition of additive manufactured metals. PMID:26506349

  2. Nonlinear Response of Thin Cylindrical Shells with Longitudinal Cracks and Subjected to Internal Pressure and Axial compression Loads

    NASA Technical Reports Server (NTRS)

    Starnes, James H.; Rose, Cheryl A.

    1998-01-01

    The results of an analytical study of the nonlinear response of a thin unstiffened aluminum cylindrical shell with a longitudinal crack are presented. The shell is analyzed with a nonlinear shell analysis code that maintains the shell in a nonlinear equilibrium state while the crack is grown. The analysis accurately accounts for global and local structural response phenomena. Results are presented for internal pressure, axial compression, and combined internal pressure and axial compression loads. The effects of varying crack length on the nonlinear response of the shell subjected to internal pressure are described. The effects of varying crack length on the prebuckling, buckling and postbuckling responses of the shell subjected to axial compression, and subjected to combined internal pressure and axial compression are also described. The results indicate that the nonlinear interaction between the in-plane stress resultants and the out-of-plane displacements near a crack can significantly affect the structural response of the shell. The results also indicate that crack growth instabilities and shell buckling instabilities can both affect the response of the shell as the crack length is increased.

  3. Impact of environmental hazards on internal soiling within concentrator photovoltaic (CPV) modules

    NASA Astrophysics Data System (ADS)

    Ellis, Sara

    2014-09-01

    Environmental conditions have a significant impact on internal soiling of a CPV system, which affects overall system performance and efficiency. The International Electrotechnical Commission (IEC) 62108, Section 10, standard includes accelerated testing such as temperature cycling, damp heat, and humidity freeze to assess a CPV module's ability to withstand environmental hazards that can compromise the typical 25-year lifetime. This paper discusses the IEC 60529 ingress protection (IP) test protocols and how they can be used to evaluate the performance of CPV modules to block water and particulate contaminants. Studies with GORE® Protective Vents installed in a CPV module and subjected to environmental hazard testing have shown increased reliability of the module over the lifetime of the system by protecting the seals from pressure differentials and keeping out contaminants.

  4. Determination of surface tension from the measurement of internal pressure of mini soap bubbles

    NASA Astrophysics Data System (ADS)

    Behroozi, F.; Behroozi, P. S.

    2011-11-01

    We review the elementary theory that gives the internal pressure of a soap bubble in terms of its radius and surface tension. The theory is generalized to relate the pressure difference across any element of a soap film to its local curvature. This result is used to introduce the concept of the mean curvature of a surface element and is applied to a double soap bubble to obtain the relation between the three radii that characterize its geometry. We also describe a simple setup, suitable for the undergraduate laboratory, to produce mini bubbles and to obtain the surface tension of the soap solution by measuring the radius and internal pressure of the bubbles.

  5. Effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco.

    PubMed

    Makan, Abdelhadi; Assobhei, Omar; Mountadar, Mohammed

    2013-01-03

    This study aimed to evaluate the effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco in terms of internal temperature, produced gases quantity, organic matter conversion rate, and the quality of the final composts.For this purpose, in-vessel bioreactor was designed and used to evaluate both appropriate initial air pressure and appropriate initial moisture content for the composting process. Moreover, 5 experiments were carried out within initial moisture content of 55%, 65%, 70%, 75% and 85%. The initial air pressure and the initial moisture content of the mixture showed a significant effect on the aerobic composting. The experimental results demonstrated that for composting organic waste, relatively high moisture contents are better at achieving higher temperatures and retaining them for longer times.This study suggested that an initial moisture content of around 75%, under 0.6 bar, can be considered as being suitable for efficient composting of organic fraction of municipal solid waste. These last conditions, allowed maximum value of temperature and final composting product with good physicochemical properties as well as higher organic matter degradation and higher gas production. Moreover, final compost obtained showed good maturity levels and can be used for agricultural applications.

  6. Effect of temperature and O-ring gland finish on sealing ability of Viton V747-75

    NASA Technical Reports Server (NTRS)

    Lach, Cynthia L.

    1993-01-01

    As a part of the redesign project of the Space Shuttle solid rocket motor (SRM) following the Challenger accident, the field joint was redesigned to minimize the relative joint motion caused by internal motor pressurization during ignition. The O-ring seals and glands for the field joint were designed both to accommodate structural deflections and to promote pressure-assisted sealing. Tests were conducted in various face seal fixtures to evaluate the ability of Viton V747-75 O-rings to seal for a range of temperatures and surface finishes of the redesigned O-ring gland. The effect of surface finish on the sealing performance and wear characteristics of the O-rings was evaluated during simulated launch conditions that included low-frequency vibrations, gap openings, and rapid pressurizations. The effect of contamination on the sealing performance was also investigated. The O-rings sealed throughout the 75 deg F leak check test and for the seal tests from 50 deg F to 120 deg F for the range of surface finishes investigated. Although abrasions were found in the O-rings from pressurization against the rougher finishes, these abrasions were not detrimental to sealing. Below 50 deg F, Viton V747-75 O-rings were insufficiently resilient to track the test gap opening.

  7. Outdoor dynamic subject-specific evaluation of internal stresses in the residual limb: hydraulic energy-stored prosthetic foot compared to conventional energy-stored prosthetic feet.

    PubMed

    Portnoy, Sigal; Kristal, Anat; Gefen, Amit; Siev-Ner, Itzhak

    2012-01-01

    The prosthetic foot plays an important role in propelling, breaking, balancing and supporting body loads while the amputee ambulates on different grounds. It is therefore important to quantify the effect of the prosthetic foot mechanism on biomechanical parameters, in order to prevent pressure ulcers and deep tissue injury. Our aim was to monitor the internal stresses in the residuum of transtibial amputation (TTA) prosthetic-users ambulating on different terrains, which the amputees encounter during their daily activities, i.e. paved floor, grass, ascending and descending stairs and slope. We specifically aimed to compare between the internal stresses in the TTA residuum of amputees ambulating with a novel hydraulic prosthetic foot compared to conventional energy storage and return (ESR) prosthetic feet. Monitoring of internal stresses was accomplished using a portable subject-specific real-time internal stress monitor. We found significant decrease (p<0.01) in peak internal stresses and in the loading rate of the amputated limb, while walking with the hydraulic foot, compared to walking with ESR feet. The loading rate calculated while ambulating with the hydraulic foot was at least three times lower than the loading rate calculated while ambulating with the ESR foot. Although the average decrease in internal stresses was ≈ 2-fold larger when replacing single-toe ESR feet with the hydraulic foot than when replacing split-toed ESR feet with the hydraulic foot, the differences were statistically insignificant. Our findings suggest that using a hydraulic prosthetic foot may protect the distal tibial end of the TTA residuum from high stresses, therefore preventing pressure-related injury and pain. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Internal short circuit and accelerated rate calorimetry tests of lithium-ion cells: Considerations for methane-air intrinsic safety and explosion proof/flameproof protection methods.

    PubMed

    Dubaniewicz, Thomas H; DuCarme, Joseph P

    2016-09-01

    Researchers with the National Institute for Occupational Safety and Health (NIOSH) studied the potential for lithium-ion cell thermal runaway from an internal short circuit in equipment for use in underground coal mines. In this third phase of the study, researchers compared plastic wedge crush-induced internal short circuit tests of selected lithium-ion cells within methane (CH 4 )-air mixtures with accelerated rate calorimetry tests of similar cells. Plastic wedge crush test results with metal oxide lithium-ion cells extracted from intrinsically safe evaluated equipment were mixed, with one cell model igniting the chamber atmosphere while another cell model did not. The two cells models exhibited different internal short circuit behaviors. A lithium iron phosphate (LiFePO 4 ) cell model was tolerant to crush-induced internal short circuits within CH 4 -air, tested under manufacturer recommended charging conditions. Accelerating rate calorimetry tests with similar cells within a nitrogen purged 353-mL chamber produced ignitions that exceeded explosion proof and flameproof enclosure minimum internal pressure design criteria. Ignition pressures within a 20-L chamber with 6.5% CH 4 -air were relatively low, with much larger head space volume and less adiabatic test conditions. The literature indicates that sizeable lithium thionyl chloride (LiSOCl 2 ) primary (non rechargeable) cell ignitions can be especially violent and toxic. Because ignition of an explosive atmosphere is expected within explosion proof or flameproof enclosures, there is a need to consider the potential for an internal explosive atmosphere ignition in combination with a lithium or lithium-ion battery thermal runaway process, and the resulting effects on the enclosure.

  9. Response of Ceratitis capitata, Bactrocera dorsalis, and Bactrocera cucurbitae (Diptera: Tephritidae) to metabolic stress disinfection and disinfestation treatment.

    PubMed

    Arévalo-Galarza, Lourdes; Follett, Peter A

    2011-02-01

    Metabolic stress disinfection and disinfestation (MSDD) is a postharvest treatment designed to control pathogens and arthropod pests on commodities that combines short cycles of low pressure/vacuum and high CO2 with ethanol vapor. Experiments were conducted to evaluate the effect of MSDD treatment on various life stages of Ceratitis capitata (Wiedemann), Mediterranean fruit fly; Bactrocera dorsalis Hendel, oriental fruit fly; and Bactrocera cucurbitae Coquillett, melon fly, in petri dishes and in papaya, Carica papaya L., fruit. In some experiments, the ethanol vapor phase was withheld to separate the effects of the physical (low pressure/ambient pressure cycles) and chemical (ethanol vapor plus low pressure) phases of treatment. In the experiments with tephritid fruit fly larvae and adults in petri dishes, mortality was generally high when insects were exposed to ethanol and low when ethanol was withheld during MSDD treatment, suggesting that ethanol vapor is highly lethal but that fruit flies are quite tolerant of short periods of low pressure treatment alone. When papaya fruit infested with fruit fly eggs or larvae were treated by MSDD, they produced fewer pupae than untreated control fruit, but a substantial number of individuals developed nonetheless. This suggests that internally feeding insects in fruit may be partially protected from the toxic effects of the ethanol because the vapor does not easily penetrate the fruit pericarp and pulp. MSDD treatment using the atmospheric conditions tested has limited potential as a disinfestation treatment for internal-feeding quarantine pests such as fruit flies infesting perishable commodities.

  10. Use of Pressure Sensitive Paint for Diagnostics in Turbomachinery Flows With Shocks

    NASA Technical Reports Server (NTRS)

    Lepicovsky, Jan; Bencic, Timothy J.

    2001-01-01

    The technology of pressure sensitive paint (PSP) is well established in external aerodynamics. In internal flows in narrow channels and in turbomachinery cascades, however, there are still unresolved problems. In particular, the internal flows with complex shock structures inside highly curved channels present a challenge. It is not always easy and straightforward to distinguish between true signals and "ghost" images due to multiple internal reflections in narrow channels. To address some of the problems, investigations were first carried out in a narrow supersonic channel of Mach number 2.5. A single wedge or a combination of two wedges were used to generate a complex shock wave structure in the flow. The experience gained in a small supersonic channel was used for surface pressure measurements on the stator vane of a supersonic throughflow fan. The experimental results for several fan operating conditions are shown in a concise form, including performance map points, midspan static tap pressure distributions, and vane suction side pressure fields. Finally, the PSP technique was used in the NASA transonic flutter cascade to compliment flow visualization data and to acquire backwall pressure fields to assess the cascade flow periodicity. A summary of shortcomings of the pressure sensitive paint technology for internal flow application and lessons learned are presented in the conclusion of the paper.

  11. Internal to external jugular vein bypass allowing for simultaneous bilateral radical neck dissection.

    PubMed

    Mourad, Moustafa; Saman, Masoud; Ducic, Yadranko

    2015-11-01

    The goal of the study was to determine the role of internal jugular vein (IJV) to external jugular vein (EJV) bypass grafting in the setting of bilateral radical neck dissection with IJV sacrifice. The study group consisted of eight patients who underwent bilateral radical neck dissection with IJV sacrifice. Demographic and oncologic parameters were defined for each patient, including age, gender, and pathology. Patients were monitored and evaluated for potential effects of increased intracranial pressure (ICP). Doppler ultrasonic evaluation was performed to assess patency of the site of anastamoses. In all, six patients underwent unilateral bypass grafting, whereas two patients underwent bilateral bypass grafts. Average age at time of surgery was 68.2 (range 56-71). Postoperatively, no sequelae of increased ICP were noted. Follow-up ultrasonic evaluation revealed patent vessels in all patients. We presently report on the use of EJV-to-IJV bypass grafting for all patients undergoing bilateral radical neck dissection for extensive neck disease. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Anatomical and functional characteristics of carotid sinus stimulation in humans

    NASA Technical Reports Server (NTRS)

    Querry, R. G.; Smith, S. A.; Stromstad, M.; Ide, K.; Secher, N. H.; Raven, P. B.

    2001-01-01

    Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

  13. ADDITIONAL STRESS AND FRACTURE MECHANICS ANALYSES OF PRESSURIZED WATER REACTOR PRESSURE VESSEL NOZZLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walter, Matthew; Yin, Shengjun; Stevens, Gary

    2012-01-01

    In past years, the authors have undertaken various studies of nozzles in both boiling water reactors (BWRs) and pressurized water reactors (PWRs) located in the reactor pressure vessel (RPV) adjacent to the core beltline region. Those studies described stress and fracture mechanics analyses performed to assess various RPV nozzle geometries, which were selected based on their proximity to the core beltline region, i.e., those nozzle configurations that are located close enough to the core region such that they may receive sufficient fluence prior to end-of-life (EOL) to require evaluation of embrittlement as part of the RPV analyses associated with pressure-temperaturemore » (P-T) limits. In this paper, additional stress and fracture analyses are summarized that were performed for additional PWR nozzles with the following objectives: To expand the population of PWR nozzle configurations evaluated, which was limited in the previous work to just two nozzles (one inlet and one outlet nozzle). To model and understand differences in stress results obtained for an internal pressure load case using a two-dimensional (2-D) axi-symmetric finite element model (FEM) vs. a three-dimensional (3-D) FEM for these PWR nozzles. In particular, the ovalization (stress concentration) effect of two intersecting cylinders, which is typical of RPV nozzle configurations, was investigated. To investigate the applicability of previously recommended linear elastic fracture mechanics (LEFM) hand solutions for calculating the Mode I stress intensity factor for a postulated nozzle corner crack for pressure loading for these PWR nozzles. These analyses were performed to further expand earlier work completed to support potential revision and refinement of Title 10 to the U.S. Code of Federal Regulations (CFR), Part 50, Appendix G, Fracture Toughness Requirements, and are intended to supplement similar evaluation of nozzles presented at the 2008, 2009, and 2011 Pressure Vessels and Piping (PVP) Conferences. This work is also relevant to the ongoing efforts of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code, Section XI, Working Group on Operating Plant Criteria (WGOPC) efforts to incorporate nozzle fracture mechanics solutions into a revision to ASME B&PV Code, Section XI, Nonmandatory Appendix G.« less

  14. Opto-mechanical analysis of nonlinear elastomer membrane deformation under hydraulic pressure for variable-focus liquid-filled microlenses.

    PubMed

    Choi, Seung Tae; Son, Byeong Soo; Seo, Gye Won; Park, Si-Young; Lee, Kyung-Sick

    2014-03-10

    Nonlinear large deformation of a transparent elastomer membrane under hydraulic pressure was analyzed to investigate its optical performance for a variable-focus liquid-filled membrane microlens. In most membrane microlenses, actuators control the hydraulic pressure of optical fluid so that the elastomer membrane together with the internal optical fluid changes its shape, which alters the light path of the microlens to adapt its optical power. A fluid-structure interaction simulation was performed to estimate the transient behavior of the microlens under the operation of electroactive polymer actuators, demonstrating that the viscosity of the optical fluid successfully stabilizes the fluctuations within a fairly short period of time during dynamic operations. Axisymmetric nonlinear plate theory was used to calculate the deformation profile of the membrane under hydrostatic pressure, with which optical characteristics of the membrane microlens were estimated. The effects of gravitation and viscoelastic behavior of the elastomer membrane on the optical performance of the membrane microlens were also evaluated with finite element analysis.

  15. 75 FR 16655 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 700 Series Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... pressure (HP-IP) turbine internal and external oil vent tubes for coking and carbon buildup, and cleaning... borescope inspections of the HP-IP turbine internal and external oil vent tubes for coking and carbon...-intermediate pressure (HP-IP) turbine internal oil vent tubes, external oil vent tubes, and bearing chamber...

  16. Evaluation of fingerprint deformation using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Gutierrez da Costa, Henrique S.; Maxey, Jessica R.; Silva, Luciano; Ellerbee, Audrey K.

    2014-02-01

    Biometric identification systems have important applications to privacy and security. The most widely used of these, print identification, is based on imaging patterns present in the fingers, hands and feet that are formed by the ridges, valleys and pores of the skin. Most modern print sensors acquire images of the finger when pressed against a sensor surface. Unfortunately, this pressure may result in deformations, characterized by changes in the sizes and relative distances of the print patterns, and such changes have been shown to negatively affect the performance of fingerprint identification algorithms. Optical coherence tomography (OCT) is a novel imaging technique that is capable of imaging the subsurface of biological tissue. Hence, OCT may be used to obtain images of subdermal skin structures from which one can extract an internal fingerprint. The internal fingerprint is very similar in structure to the commonly used external fingerprint and is of increasing interest in investigations of identify fraud. We proposed and tested metrics based on measurements calculated from external and internal fingerprints to evaluate the amount of deformation of the skin. Such metrics were used to test hypotheses about the differences of deformation between the internal and external images, variations with the type of finger and location inside the fingerprint.

  17. A Seafloor Test of the A-0-A Approach to Calibrating Pressure Sensors for Vertical Geodesy

    NASA Astrophysics Data System (ADS)

    Wilcock, W. S. D.; Manalang, D.; Harrington, M.; Cram, G.; Tilley, J.; Burnett, J.; Martin, D.; Paros, J. M.

    2017-12-01

    Seafloor geodetic observations are critical for understanding the locking and slip of the megathrust in Cascadia and other subduction zones. Differences of bottom pressure time series have been used successfully in several subduction zones to detect slow-slip earthquakes centered offshore. Pressure sensor drift rates are much greater than the long-term rates of strain build-up and thus, in-situ calibration is required to measure secular strain. One approach to calibration is to use a dead-weight tester, a laboratory apparatus that produces an accurate reference pressure, to calibrate a pressure sensor deployed on the seafloor by periodically switching between the external pressure and the deadweight tester (Cook et al, this session). The A-0-A method replaces the dead weight tester by using the internal pressure of the instrument housing as the reference pressure. We report on the first non-proprietary ocean test of this approach on the MARS cabled observatory at a depth of 900 m depth in Monterey Bay. We use the Paroscientific Seismic + Oceanic Sensors module that is designed for combined geodetic, oceanographic and seismic observations. The module comprises a three-component broadband accelerometer, two pressure sensors that for this deployment measure ocean pressures, A, up to 2000 psia (14 MPa), and a barometer to measure the internal housing reference pressure, 0. A valve periodically switches between external and internal pressures for 5 minute calibrations. The seafloor test started in mid-June and the results of 30 calibrations collected over the first 6 weeks of operation are very encouraging. After correcting for variations in the internal temperature of the housing, the offset of the pressure sensors from the barometer reading as a function of time, can be fit with a straight line for each sensor with a rms misfit of 0.1 hPa (1 mm of water). The slopes of these lines (-4 cm/yr and -0.4 cm/yr) vary by an order of magnitude but the difference in the span (external minus internal pressure) of the two sensors is constant to 0.05 hPa. We will present the results for the first 6 months of A-0-A calibrations for vertical geodesy and also discuss the performance of the pressure sensors and accelerometer for monitoring seismic activity, tilt and ocean infragravity waves.

  18. Radioisotopic cardiac pacemaker report on safety tests: crush, internal pressure, cremation; Stimulateur cardiaque radioisotopique. Essais de securite (ecrasement, pression interne, incineration) (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrard, C.; Milet, C.

    1973-03-15

    Following the results presented at the Second International Symposium on Power from Radioisotopes [Madrid, 29th May-1st June 1973] the present report describes the various tests: crush and internal pressures resistance of the radioisotopic sources as well as cremation at 1300 deg C (3370 deg F) performed on the sources, the thermoelectric batteries and the whole cardiac pacemaker.

  19. Quantification of surface tension and internal pressure generated by single mitotic cells

    NASA Astrophysics Data System (ADS)

    Fischer-Friedrich, Elisabeth; Hyman, Anthony A.; Jülicher, Frank; Müller, Daniel J.; Helenius, Jonne

    2014-08-01

    During mitosis, adherent cells round up, by increasing the tension of the contractile actomyosin cortex while increasing the internal hydrostatic pressure. In the simple scenario of a liquid cell interior, the surface tension is related to the local curvature and the hydrostatic pressure difference by Laplace's law. However, verification of this scenario for cells requires accurate measurements of cell shape. Here, we use wedged micro-cantilevers to uniaxially confine single cells and determine confinement forces while concurrently determining cell shape using confocal microscopy. We fit experimentally measured confined cell shapes to shapes obeying Laplace's law with uniform surface tension and find quantitative agreement. Geometrical parameters derived from fitting the cell shape, and the measured force were used to calculate hydrostatic pressure excess and surface tension of cells. We find that HeLa cells increase their internal hydrostatic pressure excess and surface tension from ~ 40 Pa and 0.2 mNm-1 during interphase to ~ 400 Pa and 1.6 mNm-1 during metaphase. The method introduced provides a means to determine internal pressure excess and surface tension of rounded cells accurately and with minimal cellular perturbation, and should be applicable to characterize the mechanical properties of various cellular systems.

  20. Reactor pressure vessel head vents and methods of using the same

    DOEpatents

    Gels, John L; Keck, David J; Deaver, Gerald A

    2014-10-28

    Internal head vents are usable in nuclear reactors and include piping inside of the reactor pressure vessel with a vent in the reactor upper head. Piping extends downward from the upper head and passes outside of the reactor to permit the gas to escape or be forcibly vented outside of the reactor without external piping on the upper head. The piping may include upper and lowers section that removably mate where the upper head joins to the reactor pressure vessel. The removable mating may include a compressible bellows and corresponding funnel. The piping is fabricated of nuclear-reactor-safe materials, including carbon steel, stainless steel, and/or a Ni--Cr--Fe alloy. Methods install an internal head vent in a nuclear reactor by securing piping to an internal surface of an upper head of the nuclear reactor and/or securing piping to an internal surface of a reactor pressure vessel.

  1. Predicting Large-scale Effects During Cookoff of Plastic-Bonded Explosives (PBX 9501 PBX 9502 and LX-14)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hobbs, Michael L.; Kaneshige, Michael J.; Erikson, William W.

    In this study, we have made reasonable cookoff predictions of large-scale explosive systems by using pressure-dependent kinetics determined from small-scale experiments. Scale-up is determined by properly accounting for pressure generated from gaseous decomposition products and the volume that these reactive gases occupy, e.g. trapped within the explosive, the system, or vented. The pressure effect on the decomposition rates has been determined for different explosives by using both vented and sealed experiments at low densities. Low-density explosives are usually permeable to decomposition gases and can be used in both vented and sealed configurations to determine pressure-dependent reaction rates. In contrast, explosivesmore » that are near the theoretical maximum density (TMD) are not as permeable to decomposition gases, and pressure-dependent kinetics are difficult to determine. Ignition in explosives at high densities can be predicted by using pressure-dependent rates determined from the low-density experiments as long as gas volume changes associated with bulk thermal expansion are also considered. In the current work, cookoff of the plastic-bonded explosives PBX 9501 and PBX 9502 is reviewed and new experimental work on LX-14 is presented. Reactive gases are formed inside these heated explosives causing large internal pressures. The pressure is released differently for each of these explosives. For PBX 9501, permeability is increased and internal pressure is relieved as the nitroplasticizer melts and decomposes. Internal pressure in PBX 9502 is relieved as the material is damaged by cracks and spalling. For LX-14, internal pressure is not relieved until the explosive thermally ignites. The current paper is an extension of work presented at the 26th ICDERS symposium [1].« less

  2. Internalization of Appearance Ideals Mediates the Relationship between Appearance-Related Pressures from Peers and Emotional Eating among Adolescent Boys and Girls

    PubMed Central

    Thompson, Katherine A.; Kelly, Nichole R.; Schvey, Natasha A.; Brady, Sheila M.; Courville, Amber B.; Tanofsky-Kraff, Marian; Yanovski, Susan Z.; Yanovski, Jack A.; Shomaker, Lauren B.

    2016-01-01

    Appearance-related pressures have been associated with binge eating in previous studies. Yet, it is unclear if these pressures are associated with emotional eating or if specific sources of pressure are differentially associated with emotional eating. We studied the associations between multiple sources of appearance-related pressures, including pressure to be thin and pressure to increase muscularity, and emotional eating in 300 adolescents (Mage = 15.3, SD = 1.4, 60% female). Controlling for age, race, puberty, body mass index (BMI) z-score, and sex, both pressure to be thin and pressure to be more muscular from same-sex peers were positively associated with emotional eating in response to feeling angry/frustrated and unsettled (ps<.05). Pressure from same-sex peers to be more muscular also was associated with eating when depressed (p<.05), and muscularity pressure from opposite-sex peers related to eating in response to anger/frustration (p<.05). All associations were fully mediated by internalization of appearance ideals according to Western cultural standards (ps<.001). Associations of pressures from mothers and fathers with emotional eating were non-significant. Results considering sex as a moderator of the associations between appearance-related pressures and emotional eating were non-significant. Findings illustrate that both pressure to be thin and muscular from peers are related to more frequent emotional eating among both boys and girls, and these associations are explained through internalization of appearance-related ideals. PMID:28038437

  3. Effects of internal structure on equilibrium of field-reversed configuration plasma sustained by rotating magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yambe, Kiyoyuki; Inomoto, Michiaki; Okada, Shigefumi

    The effects of an internal structure on the equilibrium of a field-reversed configuration (FRC) plasma sustained by rotating magnetic field is investigated by using detailed electrostatic probe measurements in the FRC Injection Experiment apparatus [S. Okada, et al., Nucl. Fusion. 45, 1094 (2005)]. An internal structure installed axially on the geometrical axis, which simulates Ohmic transformer or external toroidal field coils on the FRC device, brings about substantial changes in plasma density profile. The internal structure generates steep density-gradients not only on the inner side but on the outer side of the torus. The radial electric field is observed tomore » sustain the ion thermal pressure-gradient in the FRC without the internal structure; however, the radial electric field is not sufficient to sustain the increased ion thermal pressure-gradient in the FRC with the internal structure. Spontaneously driven azimuthal ion flow will be accountable for the imbalance of the radial pressure which is modified by the internal structure.« less

  4. Leakage Currents and Gas Generation in Advanced Wet Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2015-01-01

    Currently, military grade, established reliability wet tantalum capacitors are among the most reliable parts used for space applications. This has been achieved over the years by extensive testing and improvements in design and materials. However, a rapid insertion of new types of advanced, high volumetric efficiency capacitors in space systems without proper testing and analysis of degradation mechanisms might increase risks of failures. The specifics of leakage currents in wet electrolytic capacitors is that the conduction process is associated with electrolysis of electrolyte and gas generation resulting in building up of internal gas pressure in the parts. The risk associated with excessive leakage currents and increased pressure is greater for high value advanced wet tantalum capacitors, but it has not been properly evaluated yet. In this work, in Part I, leakages currents in various types of tantalum capacitors have been analyzed in a wide range of voltages, temperatures, and time under bias. Gas generation and the level of internal pressure have been calculated in Part II for different case sizes and different hermeticity leak rates to assess maximal allowable leakage currents. Effects related to electrolyte penetration to the glass seal area have been studied and the possibility of failures analyzed in Part III. Recommendations for screening and qualification to reduce risks of failures have been suggested.

  5. Space Vehicle Valve System

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  6. Modeling attitude towards drug treament: the role of internal motivation, external pressure, and dramatic relief.

    PubMed

    Conner, Bradley T; Longshore, Douglas; Anglin, M Douglas

    2009-04-01

    Motivation for change has historically been viewed as the crucial element affecting responsiveness to drug treatment. Various external pressures, such as legal coercion, may engender motivation in an individual previously resistant to change. Dramatic relief may be the change process that is most salient as individuals internalize such external pressures. Results of structural equation modeling on data from 465 drug users (58.9% male; 21.3% Black, 34.2% Hispanic/Latino, and 35.1% White) entering drug treatment indicated that internal motivation and external pressure significantly and positively predicted dramatic relief and that dramatic relief significantly predicted attitudes towards drug treatment: chi (2) = 142.20, df = 100, p < 0.01; Robust Comparative Fit Index = 0.97, Root Mean Squared Error of Approximation = 0.03. These results indicate that when external pressure and internal motivation are high, dramatic relief is also likely to be high. When dramatic relief is high, attitudes towards drug treatment are likely to be positive. The findings indicate that interventions to get individuals into drug treatment should include processes that promote Dramatic Relief. Implications for addictions health services are discussed.

  7. Cylinder pressure reconstruction based on complex radial basis function networks from vibration and speed signals

    NASA Astrophysics Data System (ADS)

    Johnsson, Roger

    2006-11-01

    Methods to measure and monitor the cylinder pressure in internal combustion engines can contribute to reduced fuel consumption, noise and exhaust emissions. As direct measurements of the cylinder pressure are expensive and not suitable for measurements in vehicles on the road indirect methods which measure cylinder pressure have great potential value. In this paper, a non-linear model based on complex radial basis function (RBF) networks is proposed for the reconstruction of in-cylinder pressure pulse waveforms. Input to the network is the Fourier transforms of both engine structure vibration and crankshaft speed fluctuation. The primary reason for the use of Fourier transforms is that different frequency regions of the signals are used for the reconstruction process. This approach also makes it easier to reduce the amount of information that is used as input to the RBF network. The complex RBF network was applied to measurements from a 6-cylinder ethanol powered diesel engine over a wide range of running conditions. Prediction accuracy was validated by comparing a number of parameters between the measured and predicted cylinder pressure waveform such as maximum pressure, maximum rate of pressure rise and indicated mean effective pressure. The performance of the network was also evaluated for a number of untrained running conditions that differ both in speed and load from the trained ones. The results for the validation set were comparable to the trained conditions.

  8. Phase transition induced strain in ZnO under high pressure

    DOE PAGES

    Yan, Xiaozhi; Dong, Haini; Li, Yanchun; ...

    2016-05-13

    Under high pressure, the phase transition mechanism and mechanical property of material are supposed to be largely associated with the transformation induced elastic strain. However, the experimental evidences for such strain are scanty. The elastic and plastic properties of ZnO, a leading material for applications in chemical sensor, catalyst, and optical thin coatings, were determined using in situ high pressure synchrotron axial and radial x-ray diffraction. The abnormal elastic behaviors of selected lattice planes of ZnO during phase transition revealed the existence of internal elastic strain, which arise from the lattice misfit between wurtzite and rocksalt phase. Furthermore, the strengthmore » decrease of ZnO during phase transition under non-hydrostatic pressure was observed and could be attributed to such internal elastic strain, unveiling the relationship between pressure induced internal strain and mechanical property of material. Ultimately, these findings are of fundamental importance to understanding the mechanism of phase transition and the properties of materials under pressure.« less

  9. Cooperation, logistics critical to well control operation in Irian Jaya jungle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gebhardt, F.; Leturno, R.

    1996-04-15

    Solving a well control problem in remote Irian Jaya, Indonesia, required fast regional and international transportation of both people and equipment. Initial information indicated that the well was experiencing an underground flow with a constant surface pressure because of a shallow hole in the 9 5/8-in. casing. The surface pressure made pipe movement inadvisable until proper pressure control equipment was in place. Several factors contributed to the overall success of this well control project. Atlantic Richfield Indonesia Inc.`s commitment to blowout contingency planning and well control team made it possible to institute a predetermined organizational structure. This organization structure providedmore » a means to gather and evaluate data quickly. Thus, crucial decisions could be made without delay, and proper personnel and equipment were mobilized. This paper reviews the step-by-step process used in this effort.« less

  10. Indicator system provides complete data of engine cylinder pressure variation

    NASA Technical Reports Server (NTRS)

    Mc Jones, R. W.; Morgan, N. E.

    1966-01-01

    Varying reference pressure used together with a balanced pressure pickup /a diaphragm switch/ to switch the electric output of the pressure transducer in a reference pressure line obtains precise engine cylinder pressure data from a high speed internal combustion engine.

  11. Getting evidence-based pressure ulcer prevention into practice: a process evaluation of a multifaceted intervention in a hospital setting.

    PubMed

    Sving, Eva; Fredriksson, Lennart; Gunningberg, Lena; Mamhidir, Anna-Greta

    2017-10-01

    To describe registered nurses', assistant nurses' and first-line managers' experiences and perceptions of a multifaceted hospital setting intervention focused on implementing evidence-based pressure ulcer prevention. Pressure ulcer prevention is deficient. Different models exist to support implementation of evidence-based care. Little is known about implementation processes. A descriptive qualitative approach. Five focus-group nurse interviews and five individual first-line manager interviews were conducted at five Swedish hospital units. Qualitative content analysis was used. The findings support that the intervention and the implementation process changed the understanding and way of working with pressure ulcer prevention: from treating to preventing. This became possible as 'Changed understanding enables changed actions - through one's own performance and reflection on pressure ulcer prevention'. Having a common outlook on pressure ulcer prevention, easy access to pressure-reducing equipment, and external and internal facilitator support were described as important factors for changed practices. Bedside support, feedback and discussions on current results increased the awareness of needed improvements. The multifaceted intervention approach and the participants' positive attitudes seemed to be crucial for changing understanding and working more preventatively. The strategies used and the skills of the facilitators need to be tailored to the problems surrounding the context. Feedback discussions among the staff regarding the results of the care provided also appear to be vital. It is crucial that dedicated facilitators are involved to promote the implementation process. A preventative mindset should be strived for. Creating an implementation plan with an outcome and a process evaluation should be emphasised. It is important to give the staff regular feedback on the quality of care and on those occasions allocate time for discussion and reflection. © 2016 John Wiley & Sons Ltd.

  12. Damage Control Plan for International Space Station Recharge Tank Assembly Composite Overwrapped Pressure Vessel

    NASA Technical Reports Server (NTRS)

    Cook, Anthony J.

    2011-01-01

    As NASA has retired the Space Shuttle Program, a new method of transporting compressed gaseous nitrogen and oxygen needed to be created for delivery of these crucial life support resources to the International Space Station (ISS). One of the methods selected by NASA includes the use of highly pressurized, unprotected Recharge Tank Assemblies (RTAs) utilizing Composite Overwrapped Pressure Vessels (COPVs). A COPV consists of a thin liner wrapped with a fiber composite and resin or epoxy. It is typically lighter weight than an all metal pressure vessel of similar volume and therefore provides a higher-efficiency means for gas storage. However COPVs are known to be susceptible to damage resulting from handling, tool drop impacts, or impacts from other objects. As a result, a comprehensive Damage Control Plan has been established to mitigate damage to the RTA COPV throughout its life cycle. The DCP is intended to evaluate and mitigate defined threats during manufacturing, shipping and handling, test, assembly level integration, shipment while pressurized, launch vehicle integration and mission operations by defining credible threats and methods for preventing potential damage while still maintaining the primary goal of resupplying ISS gas resources. A comprehensive threat assessment is performed to identify all threats posed to the COPV during the different phases of its lifecycle. The threat assessment is then used as the basis for creating a series of general inspection, surveillance and reporting requirements which apply across all phases of the COPV's life, targeted requirements only applicable to specific work phases and a series of training courses for both ground personnel and crew aboard the ISS. A particularly important area of emphasis deals with creating DCP requirements for a highly pressurized, large and unprotected RTA COPV for use during Inter Vehicular Activities (IVA) operations in the micro gravity environment while supplying pressurized gas to the ISS for crew life support.

  13. Inertial motion capture system for biomechanical analysis in pressure suits

    NASA Astrophysics Data System (ADS)

    Di Capua, Massimiliano

    A non-invasive system has been developed at the University of Maryland Space System Laboratory with the goal of providing a new capability for quantifying the motion of the human inside a space suit. Based on an array of six microprocessors and eighteen microelectromechanical (MEMS) inertial measurement units (IMUs), the Body Pose Measurement System (BPMS) allows the monitoring of the kinematics of the suit occupant in an unobtrusive, self-contained, lightweight and compact fashion, without requiring any external equipment such as those necessary with modern optical motion capture systems. BPMS measures and stores the accelerations, angular rates and magnetic fields acting upon each IMU, which are mounted on the head, torso, and each segment of each limb. In order to convert the raw data into a more useful form, such as a set of body segment angles quantifying pose and motion, a series of geometrical models and a non-linear complimentary filter were implemented. The first portion of this works focuses on assessing system performance, which was measured by comparing the BPMS filtered data against rigid body angles measured through an external VICON optical motion capture system. This type of system is the industry standard, and is used here for independent measurement of body pose angles. By comparing the two sets of data, performance metrics such as BPMS system operational conditions, accuracy, and drift were evaluated and correlated against VICON data. After the system and models were verified and their capabilities and limitations assessed, a series of pressure suit evaluations were conducted. Three different pressure suits were used to identify the relationship between usable range of motion and internal suit pressure. In addition to addressing range of motion, a series of exploration tasks were also performed, recorded, and analysed in order to identify different motion patterns and trajectories as suit pressure is increased and overall suit mobility is reduced. The focus of these evaluations was to quantify the reduction in mobility when operating in any of the evaluated pressure suits. This data should be of value in defining new low cost alternatives for pressure suit performance verification and evaluation. This work demonstrates that the BPMS technology is a viable alternative or companion to optical motion capture; while BPMS is the first motion capture system that has been designed specifically to measure the kinematics of a human in a pressure suit, its capabilities are not constrained to just being a measurement tool. The last section of the manuscript is devoted to future possible uses for the system, with a specific focus on pressure suit applications such in the use of BPMS as a master control interface for robot teleoperation, as well as an input interface for future robotically augmented pressure suits.

  14. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. AA1921-167 (Third Review)] Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: February 16, 2010. FOR FURTHER INFORMATION CONTACT: Edward...

  15. Numerical investigations on pressurized AL-composite vessel response to hypervelocity impacts: Comparison between experimental works and a numerical code

    NASA Astrophysics Data System (ADS)

    Mespoulet, Jérôme; Plassard, Fabien; Hereil, Pierre-Louis

    2015-09-01

    Response of pressurized composite-Al vessels to hypervelocity impact of aluminum spheres have been numerically investigated to evaluate the influence of initial pressure on the vulnerability of these vessels. Investigated tanks are carbon-fiber overwrapped prestressed Al vessels. Explored internal air pressure ranges from 1 bar to 300 bar and impact velocity are around 4400 m/s. Data obtained from experiments (Xray radiographies, particle velocity measurement and post-mortem vessels) have been compared to numerical results given from LS-DYNA ALE-Lagrange-SPH full coupling models. Simulations exhibit an under estimation in term of debris cloud evolution and shock wave propagation in pressurized air but main modes of damage/rupture on the vessels given by simulations are coherent with post-mortem recovered vessels from experiments. First results of this numerical work are promising and further simulation investigations with additional experimental data will be done to increase the reliability of the simulation model. The final aim of this crossed work is to numerically explore a wide range of impact conditions (impact angle, projectile weight, impact velocity, initial pressure) that cannot be explore experimentally. Those whole results will define a rule of thumbs for the definition of a vulnerability analytical model for a given pressurized vessel.

  16. Treatment strategy according to findings on pressure-flow study for women with decreased urinary flow rate.

    PubMed

    Tanaka, Yoshinori; Masumori, Naoya; Tsukamoto, Taiji; Furuya, Seiji; Furuya, Ryoji; Ogura, Hiroshi

    2009-01-01

    In women who reported a weak urinary stream, the efficacy of treatment chosen according to the urodynamic findings on pressure-flow study was prospectively evaluated. Twelve female patients with maximum flow rates of 10 mL/sec or lower were analyzed in the present study. At baseline, all underwent pressure-flow study to determine the degree of bladder outlet obstruction (BOO) and status of detrusor contractility on Schäfer's diagram. Distigmine bromide, 10 mg/d, was given to the patients with detrusor underactivity (DUA) defined as weak/very weak contractility, whereas urethral dilatation was performed using a metal sound for those with BOO (linear passive urethral resistance relation 2-6). Treatment efficacy was evaluated using the International Prostate Symptom Score (IPSS), uroflowmetry, and measurement of postvoid residual urine volume. Some patients underwent pressure-flow study after treatment. Urethral dilatation was performed for six patients with BOO, while distigmine bromide was given to the remaining six showing DUA without BOO. IPSS, QOL index, and the urinary flow rate were significantly improved in both groups after treatment. All four of the patients with BOO and one of the three with DUA but no BOO who underwent pressure-flow study after treatment showed decreased degrees of BOO and increased detrusor contractility, respectively. Both BOO and DUA cause a decreased urinary flow rate in women. In the short-term, urethral dilatation and distigmine bromide are efficacious for female patients with BOO and those with DUA, respectively.

  17. A Field Evaluation of an External and Neutrally Buoyant Acoustic Transmitter for Juvenile Salmon: Implications for Estimating Hydroturbine Passage Survival

    PubMed Central

    Brown, Richard S.; Deng, Z. Daniel; Cook, Katrina V.; Pflugrath, Brett D.; Li, Xinya; Fu, Tao; Martinez, Jayson J.; Li, Huidong; Trumbo, Bradly A.; Ahmann, Martin L.; Seaburg, Adam G.

    2013-01-01

    Turbine-passed fish are exposed to rapid decreases in pressure which can cause barotrauma. The presence of an implanted telemetry tag increases the likelihood of injury or death from exposure to pressure changes, thus potentially biasing studies evaluating survival of turbine-passed fish. Therefore, a neutrally buoyant externally attached tag was developed to eliminate this bias in turbine passage studies. This new tag was designed not to add excess mass in water or take up space in the coelom, having an effective tag burden of zero with the goal of reducing pressure related biases to turbine survival studies. To determine if this new tag affects fish performance or susceptibility to predation, it was evaluated in the field relative to internally implanted acoustic transmitters (JSATS; Juvenile Salmon Acoustic Telemetry System) used widely for survival studies of juvenile salmonids. Survival and travel time through the study reach was compared between fish with either tag type in an area of high predation in the Snake and Columbia rivers, Washington. An additional group of fish affixed with neutrally-buoyant dummy external tags were implanted with passive integrated transponder (PIT) tags and recovered further downstream to assess external tag retention and injury. There were no significant differences in survival to the first detection site, 12 river kilometers (rkm) downstream of release. Travel times were also similar between groups. Conversely, externally-tagged fish had reduced survival (or elevated tag loss) to the second detection site, 65 rkm downstream. In addition, the retention study revealed that tag loss was first observed in fish recaptured approximately 9 days after release. Results suggest that this new tag may be viable for short term (<8 days) single-dam turbine-passage studies and under these situations, may alleviate the turbine passage-related bias encountered when using internal tags, however further research is needed to confirm this. PMID:24204947

  18. A field evaluation of an external and neutrally buoyant acoustic transmitter for juvenile salmon: implications for estimating hydroturbine passage survival.

    PubMed

    Brown, Richard S; Deng, Z Daniel; Cook, Katrina V; Pflugrath, Brett D; Li, Xinya; Fu, Tao; Martinez, Jayson J; Li, Huidong; Trumbo, Bradly A; Ahmann, Martin L; Seaburg, Adam G

    2013-01-01

    Turbine-passed fish are exposed to rapid decreases in pressure which can cause barotrauma. The presence of an implanted telemetry tag increases the likelihood of injury or death from exposure to pressure changes, thus potentially biasing studies evaluating survival of turbine-passed fish. Therefore, a neutrally buoyant externally attached tag was developed to eliminate this bias in turbine passage studies. This new tag was designed not to add excess mass in water or take up space in the coelom, having an effective tag burden of zero with the goal of reducing pressure related biases to turbine survival studies. To determine if this new tag affects fish performance or susceptibility to predation, it was evaluated in the field relative to internally implanted acoustic transmitters (JSATS; Juvenile Salmon Acoustic Telemetry System) used widely for survival studies of juvenile salmonids. Survival and travel time through the study reach was compared between fish with either tag type in an area of high predation in the Snake and Columbia rivers, Washington. An additional group of fish affixed with neutrally-buoyant dummy external tags were implanted with passive integrated transponder (PIT) tags and recovered further downstream to assess external tag retention and injury. There were no significant differences in survival to the first detection site, 12 river kilometers (rkm) downstream of release. Travel times were also similar between groups. Conversely, externally-tagged fish had reduced survival (or elevated tag loss) to the second detection site, 65 rkm downstream. In addition, the retention study revealed that tag loss was first observed in fish recaptured approximately 9 days after release. Results suggest that this new tag may be viable for short term (<8 days) single-dam turbine-passage studies and under these situations, may alleviate the turbine passage-related bias encountered when using internal tags, however further research is needed to confirm this.

  19. Exploration of COTS Ultrasonic NDE Methods for ISS MMOD Impact Analysis

    NASA Technical Reports Server (NTRS)

    Violette, Daniel P.; Koshti, Ajay; Stanley, David

    2012-01-01

    The high orbital speed of the International Space Station (ISS) has created a concern about Micro-Meteorite and Orbital Debris (MMOD). The possibility exists that such an impact could cause significant damage to the ISS pressure wall, and possibly lead to a pressure leak. This paper explores the potential of using commercial off-the-shelf (COTS) Ultrasonic Non-Destructive Evaluation (NDE) techniques in order to inspect and analyze MMOD impact damage if such an event would happen to occur. Different types of intra vehicular activity (IVA) Ultrasonic NDE equipment were evaluated, including the Olympus Omniscan MX and the General Electric Phasor XS. The equipment was tested by inspecting various aluminum standards and impact damage test plates in order to determine technological limitations of the equipment as well as the ease of use and availability of features. This study allowed for the design of scanning procedures in order to evaluate the extent of damage caused by an MMOD impact. Lastly, comparisons were drawn between the different pieces of COTS software and a recommendation is made based on each device s capability.

  20. Environmental, political, and economic determinants of water quality monitoring in Europe

    NASA Astrophysics Data System (ADS)

    Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna

    2010-11-01

    Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.

  1. Fiber optic sensor technology - An opportunity for smart aerospace structures

    NASA Technical Reports Server (NTRS)

    Heyman, J. S.; Rogowski, R. S.; Claus, R. O.

    1988-01-01

    Fiber optic sensors provide the opportunity for fabricating materials with internal sensors which can serve as lifetime health monitors, analogous to a central nervous system. The embedded fiber optic sensors can be interrogated by various techniques to measure internal strain, temperature, pressure, acoustic waves and other parameters indicative of structural integrity. Experiments have been conducted with composite samples with embedded sensors to measure strain using optical time domain reflectometry, modal interference and an optical phase locked loop. Fiber optic sensors have been developed to detect acoustic emission and impact damage and have been demonstrated for cure monitoring. These sensors have the potential for lifetime monitoring of structural properties, providing real time nondestructive evaluation.

  2. Validation of the A&D UM-201 device for office blood pressure measurement according to the European Society of Hypertension International Protocol Revision 2010.

    PubMed

    Fania, Claudio; Albertini, Federica; Palatini, Paolo

    2017-08-01

    The aim of this study was to determine the accuracy of the A&D UM-201 device coupled to several cuffs for different arm sizes for office blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Evaluation was carried out in 33 individuals. The mean age of the individuals was 59.3±13.2 years, systolic BP was 145.4±20.6 mmHg (range: 109-186 mmHg), diastolic BP was 87.3±18.0 mmHg (range: 50-124 mmHg), and arm circumference was 30.4±4.2 cm (range: 23-39 cm). The protocol requirements were followed precisely. The UM-201 monitor passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated systolic BP by 3.0±2.1 mmHg and diastolic BP by 2.6±2.0 mmHg. These data show that the A&D UM-201 device coupled to several cuffs for different ranges of arm circumference fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  3. Validation of the A&D BP UB-542 wrist device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Saladini, Francesca; Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo

    2013-08-01

    The objective of this study was to determine the accuracy of the A&D BP UB-542 wrist device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension (ESH). Device evaluation was carried out in 33 patients. The mean age was 50.9±10.1 years, the mean systolic BP was 141.6±22.8 mmHg (range 92 : 189), the mean diastolic BP was 89.2±11.4 mmHg (range 62 : 120), the mean arm circumference was 28.8±3.2 cm (range 23-35), and the mean wrist circumference was 17.1±1.4 cm (range 14-19.5). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated the systolic BP by 1.8±7.2 mmHg and diastolic BP by 1.6±5.7 mmHg. These data show that the A&D BP UB-542 wrist device met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  4. Part 1 - Experimental study of the pressure fluctuations on propeller turbine runner blades during steady-state operation

    NASA Astrophysics Data System (ADS)

    Houde, S.; Fraser, R.; Ciocan, G. D.; Deschênes, C.

    2012-11-01

    A good evaluation of the unsteady pressure field on hydraulic turbine blades is critical in evaluating the turbine lifespan and its maintenance schedule. Low-head turbines such as Kaplan and Propeller, using a relatively low number of blades supported only at the hub, may also undergo significant deflections at the blade tips which will lead to higher amplitude vibration compared to Francis turbines. Furthermore, the precise evaluation of the unsteady pressure distribution on low-head turbines is still a challenge for computational fluid dynamics (CFD). Within the framework of an international research consortium on low-head turbines, a research project was instigated at the Hydraulic Machines Laboratory in Laval University (LAMH) to perform experimental measurements of the unsteady pressure field on propeller turbine model runner blades. The main objective of the project was to measure the pressure fluctuations on a wide band of frequencies, both in a blade-to-blade channel and on the pressure and suction side of the same blade, to provide validation data for CFD computations. To do so, a 32 channels telemetric data transmission system was used to extract the signal of 31 pressure transducers and two strain gages from the rotating part at an acquisition frequency of 5 KHz. The miniature piezoelectric pressure transducers were placed on two adjacent runner blades according to an estimated pressure distribution coming from flow simulations. Two suction sides and one pressure side were instrumented. The strain gages were mounted in full-bridge on both pressure and suction sides to measure the blade span wise deflection. In order to provide boundary conditions for flow simulations, the test bench conditions during the measurements were acquired. The measurements were made in different operating conditions ranging from part load, where a cavitating vortex occurs, to full load under different heads. The results enabled the identification and the quantification of the major known sources of pressure fluctuation as well as some unexpected ones. The paper first presents the experimental methodology discussing relevant topics such as telemetric system setup, transducers calibration and errors analysis. The main results are then presented to illustrate the relative amplitude of the main source of pressure fluctuations under different operating conditions. The discussion and conclusion addresses the important observations stemming from the data analysis and illustrates that most of the results can be correlated with the known behavior of hydraulic turbines while some require further investigation.

  5. Plate Deformation Behavior of Polymer Matrix Composite-Ti Honeycomb-Metal Sandwiches for Pressurized Propulsion Component Applications

    NASA Technical Reports Server (NTRS)

    Bertelsen, William D.; Shin, E. eugene; Thesken, John C.; Sutter, James K.; Martin, Rich

    2004-01-01

    THe objectives are: 1. To experimentally validate bi-axial plate flexural performance of PMC-Ti H/C-A286 sandwich panels for the internally pressurized RBCC combustion chamber support structure. 2. To explore ASTM 2-D plate flexure test (D 6416) to simulate the internal pressure loading and to correlate the results with analytical and FE modeling based on 2-D flexure properties.

  6. Prediction of induced vibrations for a passenger - car ferry

    NASA Astrophysics Data System (ADS)

    Crudu, L.; Neculet, O.; Marcu, O.

    2016-08-01

    In order to evaluate the ship hull global vibrations, propeller excitation must be properly considered being mandatory to know enough accurate the magnitude of the induced hull pressure impulses. During the preliminary design stages, the pressures induced on the aft part of the ship by the operating propeller can be evaluated based on the guidelines given by the international standards or by the provisions of the Classification Societies. These approximate formulas are taking into account the wake field which, unfortunately, can be only estimated unless experimental towing tank tests are carried out. Another possibility is the numerical evaluation with different Computational Fluid Dynamics (CFD) codes. However, CFD methods are not always easy to be used requiring an accurate description of the hull forms in the aft part of the ship. The present research underlines these aspects during the preliminary prediction of propeller induced vibrations for a double-ended passenger-car ferry propelled by two azimuth fixed pitch thrusters placed at both ends of the ship. The evaluation of the global forced vibration is performed considering the 3D global Finite Element (FE) model, with NX Nastran for Windows. Based on the presented results, the paper provides reliable information to be used during the preliminary design stages.

  7. Use of pressure-sensitive paint for diagnostics in turbomachinery flows with shocks

    NASA Astrophysics Data System (ADS)

    Lepicovsky, J.; Bencic, T. J.

    2002-07-01

    The technology of pressure-sensitive paint (PSP) is well established in external aerodynamics. In internal flows in narrow channels and in turbomachinery cascades, however, there are still unresolved problems. In particular, the internal flows with complex shock structures inside highly curved channels present a challenge. It is not always easy and straightforward to distinguish between true signals and 'ghost' images due to multiple internal reflections in narrow channels. To address some of the problems, investigations were first carried out in a narrow supersonic channel of Mach number 2.5. A single wedge or a combination of two wedges was used to generate a complex shock wave structure in the flow. The experience gained in a small supersonic channel was used for surface pressure measurements on the stator vane of a supersonic throughflow fan. The experimental results for several fan operating conditions are shown in a concise form, including performance map test points, midspan static tap pressure distributions, and vane suction side pressure fields. Finally, the PSP technique was used in the NASA transonic flutter cascade to compliment flow visualization data and to acquire backwall pressure fields to assess the cascade flow periodicity. Lessons learned from this investigation and shortcomings of the PSP technology for internal flow application are presented in the conclusion of the paper.

  8. Internalization of appearance ideals mediates the relationship between appearance-related pressures from peers and emotional eating among adolescent boys and girls.

    PubMed

    Thompson, Katherine A; Kelly, Nichole R; Schvey, Natasha A; Brady, Sheila M; Courville, Amber B; Tanofsky-Kraff, Marian; Yanovski, Susan Z; Yanovski, Jack A; Shomaker, Lauren B

    2017-01-01

    Appearance-related pressures have been associated with binge eating in previous studies. Yet, it is unclear if these pressures are associated with emotional eating or if specific sources of pressure are differentially associated with emotional eating. We studied the associations between multiple sources of appearance-related pressures, including pressure to be thin and pressure to increase muscularity, and emotional eating in 300 adolescents (M age =15.3, SD=1.4, 60% female). Controlling for age, race, puberty, body mass index (BMI) z-score, and sex, both pressure to be thin and pressure to be more muscular from same-sex peers were positively associated with emotional eating in response to feeling angry/frustrated and unsettled (ps<0.05). Pressure from same-sex peers to be more muscular also was associated with eating when depressed (p<0.05), and muscularity pressure from opposite-sex peers related to eating in response to anger/frustration (p<0.05). All associations were fully mediated by internalization of appearance ideals according to Western cultural standards (ps<0.001). Associations of pressures from mothers and fathers with emotional eating were non-significant. Results considering sex as a moderator of the associations between appearance-related pressures and emotional eating were non-significant. Findings illustrate that both pressure to be thin and muscular from peers are related to more frequent emotional eating among both boys and girls, and these associations are explained through internalization of appearance-related ideals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The long-term effects of arteriovenous fistula creation on the development of pulmonary hypertension in hemodialysis patients.

    PubMed

    Unal, Aydin; Tasdemir, Kutay; Oymak, Sema; Duran, Mustafa; Kocyigit, Ismail; Oguz, Fatih; Tokgoz, Bulent; Sipahioglu, Murat Hayri; Utas, Cengiz; Oymak, Oktay

    2010-10-01

    The aim of this prospective study was to evaluate long-term effects of arteriovenous fistula (AVF) on the development of pulmonary arterial hypertension (PAH) and the relationship between blood flow rate of AVF and pulmonary artery pressure (PAP) in the patients with end-stage renal disease (ESRD). This prospective study was performed in 20 patients with ESRD. Before an AVF was surgically created for hemodialysis, the patients were evaluated by echocardiography. Then, an AVF was surgically created in all patients. After mean 23.50 ± 2.25 months, the second evaluation was performed by echocardiography. Also, the blood flow rate of AVF was measured at the second echocardiographic evaluation. Pulmonary arterial hypertension was defined as a systolic PAP above 35 mmHg at rest. Mean age of 20 patients with ESRD was 55.05 ± 13.64 years; 11 of 20 patients were males. Pulmonary arterial hypertension was detected in 6 (30%) patients before AVF creation and in 4 (20%) patients after AVF creation. Systolic PAP value was meaningfully lower after AVF creation than before AVF creation (29.95 ± 10.26 mmHg vs. 35.35 ± 7.86 mmHg, respectively, P: 0.047). However, there was no significant difference between 2 time periods in terms of presence of PAH (P>0.05). Pulmonary artery pressure did not correlate with blood flow rate of AVF and duration after AVF creation (P>0.05). In hemodialysis patients, a surgically created AVF has no significant effect on the development of PAH within a long-term period. Similarly, blood flow rate of AVF also did not affect remarkably systolic PAP within the long-term period. © 2010 The Authors. Hemodialysis International © 2010 International Society for Hemodialysis.

  10. Development and validation of the sociocultural attitudes towards appearance questionnaire-4-revised (SATAQ-4R).

    PubMed

    Schaefer, Lauren M; Harriger, Jennifer A; Heinberg, Leslie J; Soderberg, Taylor; Kevin Thompson, J

    2017-02-01

    The Sociocultural Attitudes Toward Appearance Questionnaire-4 (SATAQ-4) is a measure of internalization of appearance ideals (i.e., personal acceptance of societal ideals) and appearance pressures (i.e., pressures to achieve the societal ideal). The current study sought to address limitations of the scale in order to increase precision in the measurement of muscular ideal internalization, include an assessment of one's desire for attractiveness, and broaden the measurement of appearance-related pressures. The factor structure, reliability and construct validity of the SATAQ-4-Revised were examined among college women (N = 1,114) in Study 1, adolescent girls (N = 275) in Study 2, and college men (N = 290) in Study 3. Factor analysis among college women indicated a 7-factor 31-item scale, labeled the SATAQ-4R-Female: (1) Internalization: Thin/Low Body Fat, (2) Internalization: Muscular, (3) Internalization: General Attractiveness, (4) Pressures: Family, (5) Pressures: Media, (6) Pressures: Peers, and (7) Pressures: Significant Others. SATAQ-4R-Female subscales demonstrated good reliability and construct validity among college women. Examination of the SATAQ-4R-Female among adolescent girls suggested a six-factor scale in which peer and significant others items comprised a single subscale. The scale demonstrated good reliability and construct validity in adolescent girls. Examination of the SATAQ-4R among men produced a 28-item scale with seven factors paralleling the factors identified among college women. This scale, labeled the SATAQ-4R-Male, demonstrated good reliability and construct validity. Results support the reliability and validity of SATAQ-4R-Female in college women and adolescent girls, and the SATAQ-4R-Male in college men. © 2016 Wiley Periodicals, Inc.(Int J Eat Disord 2017; 50:104-117). © 2016 Wiley Periodicals, Inc.

  11. [Classifying Mexican adolescents' high blood pressure, associated factors and importance].

    PubMed

    Salcedo-Rocha, Ana L; de Alba, Javier E García; Contreras-Marmolejo, Margarita

    2010-08-01

    Determining characteristics regarding risk and high blood pressure (HBP) frequency in a group of 12 to 16 year-old students from the city of León, Mexico, according to two types of classification: the 7th Joint National Committee (JNC-7) and 4th report of the working group for diagnosis, evaluation and treatment of HBP in children and adolescents. This was an observational, descriptive cross-sectional study of 458 male students. HBP was determined according to international standards after parents and students' informed consent had been obtained and they answered a questionnaire for recording clinical-epidemiological data. Blood pressure levels were classified as being normal, pre-HBP and hyper-HBP in accordance with the guidelines issued by the 7th National Joint Committee for detecting, evaluating and treating HBP (JNC-7) and the 4th report of the working group for diagnosis, evaluation and treatment of HBP in children and adolescents. 61.3 % and 68.7 % were found to have normal blood pressure, 34.9 % and 20.7 % were pre-HBP and 3.7 % and 10.4 % hyper-HBP according to JNC-7 and 4th report guidelines, respectively, whilst 71 % and 66 % had a family background of diabetes and HBP, 22 % were overweight and obese and 24 % had a background of alcohol consumption. It is suggested that 4th report guidelines should be adopted in clinical practice whilst JNC-7 guidelines should be used for epidemiological studies. Accepting the pre-HBP concept and its early detection for preventing HBP will facilitate effective health promotion regarding changes in lifestyle.

  12. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  13. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  14. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  15. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  16. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  17. A molecular dynamics study on the role of attractive and repulsive forces in internal energy, internal pressure and structure of dense fluids

    NASA Astrophysics Data System (ADS)

    Goharshadi, Elaheh K.; Morsali, Ali; Mansoori, G. Ali

    2007-01-01

    Isotherms of experimental data of internal pressure of dense fluids versus molar volume, Vm are shown to have each a maximum point at a Vmax below the critical molar volume. In this study, we investigated the role of attractive and repulsive intermolecular energies on this behavior using a molecular dynamics simulation technique. In the simulation, we choose the Lennard-Jones (LJ) intermolecular potential energy function. The LJ potential is known to be an effective potential representing a statistical average of the true pair and many-body interactions in simple molecular systems. The LJ potential function is divided into attractive and repulsive parts. MD calculations have produced internal energy, potential energy, transitional kinetic energy, and radial distribution function (RDF) for argon at 180 K and 450 K using LJ potential, LJ repulsive, and LJ attractive parts. It is shown that the LJ potential function is well capable of predicting the inflection point in the internal energy-molar volume curve as well as maximum point in the internal pressure-molar volume curve. It is also shown that at molar volumes higher than Vmax, the attractive forces have strong influence on determination of internal energy and internal pressure. At volumes lower than Vmax, neither repulsive nor attractive forces are dominating. Also, the coincidence between RDFs resulting from LJ potential and repulsive parts of LJ potential improves as molar volume approaches Vmax from high molar volumes. The coincidence becomes complete at Vmax ⩾ V.

  18. Structural Benchmark Tests of Composite Combustion Chamber Support Completed

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Thesken, John C.; Shin, E. Eugene; Sutter, James K.

    2005-01-01

    A series of mechanical load tests was completed on several novel design concepts for extremely lightweight combustion chamber support structures at the NASA Glenn Research Center (http://www.nasa.gov/glenn/). The tests included compliance evaluation, preliminary proof loadings, high-strain cyclic testing, and finally residual strength testing of each design (see the photograph on the left). Loads were applied with single rollers (see the photograph on the right) or pressure plates (not shown) located midspan on each side to minimize the influence of contact stresses on corner deformation measurements. Where rollers alone were used, a more severe structural loading was produced than the corresponding equal-force pressure loading: the maximum transverse shear force existed over the entire length of each side, and the corner bending moments were greater than for a distributed (pressure) loading. Failure modes initiating at the corner only provided a qualitative indication of the performance limitations since the stress state was not identical to internal pressure. Configurations were tested at both room and elevated temperatures. Experimental results were used to evaluate analytical prediction tools and finite-element methodologies for future work, and they were essential to provide insight into the deformation at the corners. The tests also were used to assess fabrication and bonding details for the complicated structures. They will be used to further optimize the design of the support structures for weight performance and the efficacy of corner reinforcement.

  19. Effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco

    PubMed Central

    2013-01-01

    This study aimed to evaluate the effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco in terms of internal temperature, produced gases quantity, organic matter conversion rate, and the quality of the final composts. For this purpose, in-vessel bioreactor was designed and used to evaluate both appropriate initial air pressure and appropriate initial moisture content for the composting process. Moreover, 5 experiments were carried out within initial moisture content of 55%, 65%, 70%, 75% and 85%. The initial air pressure and the initial moisture content of the mixture showed a significant effect on the aerobic composting. The experimental results demonstrated that for composting organic waste, relatively high moisture contents are better at achieving higher temperatures and retaining them for longer times. This study suggested that an initial moisture content of around 75%, under 0.6 bar, can be considered as being suitable for efficient composting of organic fraction of municipal solid waste. These last conditions, allowed maximum value of temperature and final composting product with good physicochemical properties as well as higher organic matter degradation and higher gas production. Moreover, final compost obtained showed good maturity levels and can be used for agricultural applications. PMID:23369502

  20. An Evaluation of Liquid and Two-Phase Cooling Techniques for Use in Electrical Machinery.

    DTIC Science & Technology

    1984-12-01

    equations (3.5) & (3.6) k Thermal conductivity L Condenser length m Mass flow rate b Nu Nusselt number P Pressure Pr Prandtl number Q Heat-transfer rate...IRI finned condenser (with axially-straight or helical fins), or 4. use an internally-grooved condenser . Marto [17] presents a detailed discussion of...the appropriate models for the first two cases. For example, for rotating truncated-cone condensers , Ballback [28] performed a Nusselt -type analysis

  1. Radioisotope Stirling Engine Powered Airship for Low Altitude Operation on Venus

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.

    2012-01-01

    The feasibility of a Stirling engine powered airship for the near surface exploration of Venus was evaluated. The heat source for the Stirling engine was limited to 10 general purpose heat source (GPHS) blocks. The baseline airship utilized hydrogen as the lifting gas and the electronics and payload were enclosed in a cooled insulated pressure vessel to maintain the internal temperature at 320 K and 1 Bar pressure. The propulsion system consisted of an electric motor driving a propeller. An analysis was set up to size the airship that could operate near the Venus surface based on the available thermal power. The atmospheric conditions on Venus were modeled and used in the analysis. The analysis was an iterative process between sizing the airship to carry a specified payload and the power required to operate the electronics, payload and cooling system as well as provide power to the propulsion system to overcome the drag on the airship. A baseline configuration was determined that could meet the power requirements and operate near the Venus surface. From this baseline design additional trades were made to see how other factors affected the design such as the internal temperature of the payload chamber and the flight altitude. In addition other lifting methods were evaluated such as an evacuated chamber, heated atmospheric gas and augmented heated lifting gas. However none of these methods proved viable.

  2. Male bladder outlet obstruction: Time to re-evaluate the definition and reconsider our diagnostic pathway? ICI-RS 2015.

    PubMed

    Rademakers, Kevin; Drake, Marcus J; Gammie, Andrew; Djurhuus, Jens C; Rosier, Peter F W M; Abrams, Paul; Harding, Christopher

    2017-04-01

    The diagnosis of bladder outlet obstruction (BOO) in the male is dependent on measurements of pressure and flow made during urodynamic studies. The procedure of urodynamics and the indices used to delineate BOO are well standardized largely as a result of the work of the International Continence Society. The clinical utility of the diagnosis of BOO is however, less well defined and there are several shortcomings and gaps in the currently available medical literature. Consequently the International Consultation on Incontinence Research Society (ICI-RS) held a think tank session in 2015 entitled "Male bladder outlet obstruction: Time to re-evaluate the definition and reconsider our diagnostic pathway?" This manuscript details the discussions that took place within that think tank setting out the pros and cons of the current definition of BOO and exploring alternative clinical tests (alone or in combination) which may be useful in the future investigation of male patients with lower urinary tract symptoms. The think tank panel concluded that pressure-flow studies remain the diagnostic gold-standard for BOO although there is still a lack of high quality evidence. Newer, less invasive, investigations have shown promise in terms of diagnostic accuracy for BOO but similar criticisms can be levelled against these tests. Therefore, the think tank suggests further research with regard to these alternative indicators to determine their clinical utility. © 2017 Wiley Periodicals, Inc.

  3. Intradetrusor onabotulinumtoxinA injections for refractory neurogenic detrusor overactivity incontinence: do we need urodynamic investigation for outcome assessment?

    PubMed

    Koschorke, Miriam; Leitner, Lorenz; Sadri, Helen; Knüpfer, Stephanie C; Mehnert, Ulrich; Kessler, Thomas M

    2017-12-01

    To evaluate if urinary continence in patients with refractory neurogenic detrusor overactivity (NDO) incontinence after intradetrusor onabotulinumtoxinA injections is sufficient for appropriate outcome assessment or if urodynamic investigation (UDI) is needed. A consecutive series of 148 patients undergoing intradetrusor onabotulinumtoxinA injections for refractory NDO incontinence were prospectively evaluated. Patients underwent UDI before and at 6 weeks after onabotulinumtoxinA injections. The primary outcome was the prevalence of maximum storage detrusor pressure (Pdet max storage) of >40 cmH 2 O in continent patients at 6 weeks after treatment. The secondary outcomes were treatment effects on other clinical and video-urodynamic variables. At 6 weeks after intradetrusor onabotulinumtoxinA injections, 98 of the 148 patients (66%) with NDO incontinence were continent. Of these patients, 18 (18%, confidence interval 12-27%) had a Pdet max storage of >40 cmH 2 O. Gender, underlying neurological disorder, and high Pdet max storage before treatment appear to increase the risk of poor urodynamic outcomes. Urinary continence is not sufficient for outcome assessment after intradetrusor onabotulinumtoxinA injections, as high intravesical pressures threatening the upper urinary tract may be missed in a relevant proportion of continent patients. Therefore, we strongly recommend UDI as a routine part of the follow-up. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  4. Modeling internal ballistics of gas combustion guns.

    PubMed

    Schorge, Volker; Grossjohann, Rico; Schönekess, Holger C; Herbst, Jörg; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2016-05-01

    Potato guns are popular homemade guns which work on the principle of gas combustion. They are usually constructed for recreational rather than criminal purposes. Yet some serious injuries and fatalities due to these guns are reported. As information on the internal ballistics of homemade gas combustion-powered guns is scarce, it is the aim of this work to provide an experimental model of the internal ballistics of these devices and to investigate their basic physical parameters. A gas combustion gun was constructed with a steel tube as the main component. Gas/air mixtures of acetylene, hydrogen, and ethylene were used as propellants for discharging a 46-mm caliber test projectile. Gas pressure in the combustion chamber was captured with a piezoelectric pressure sensor. Projectile velocity was measured with a ballistic speed measurement system. The maximum gas pressure, the maximum rate of pressure rise, the time parameters of the pressure curve, and the velocity and path of the projectile through the barrel as a function of time were determined according to the pressure-time curve. The maximum gas pressure was measured to be between 1.4 bar (ethylene) and 4.5 bar (acetylene). The highest maximum rate of pressure rise was determined for hydrogen at (dp/dt)max = 607 bar/s. The muzzle energy was calculated to be between 67 J (ethylene) and 204 J (acetylene). To conclude, this work provides basic information on the internal ballistics of homemade gas combustion guns. The risk of injury to the operator or bystanders is high, because accidental explosions of the gun due to the high-pressure rise during combustion of the gas/air mixture may occur.

  5. Structural Stability of a Stiffened Aluminum Fuselage Panel Subjected to Combined Mechanical and Internal Pressure Loads

    NASA Technical Reports Server (NTRS)

    Rouse, Marshall; Young, Richard D.; Gehrki, Ralph R.

    2003-01-01

    Results from an experimental and analytical study of a curved stiffened aluminum panel subjected to combined mechanical and internal pressure loads are presented. The panel loading conditions were simulated using a D-box test fixture. Analytical buckling load results calculated from a finite element analysis are presented and compared to experimental results. Buckling results presented indicate that the buckling load of the fuselage panel is significantly influenced by internal pressure loading. The experimental results suggest that the stress distribution is uniform in the panel prior to buckling. Nonlinear finite element analysis results correlates well with experimental results up to buckling.

  6. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    PubMed

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  7. FOREWORD: CCM Second International Seminar: Pressure Metrology from 1 kPa to 1 GPa

    NASA Astrophysics Data System (ADS)

    Molinar, G. F.

    1994-01-01

    The Comité Consultatif pour la Masse et les Grandeurs Apparentées (CCM), through its High Pressure and Medium Pressure Working Groups, organized this Second International Seminar on Pressure Metrology from 1 kPa to 1 GPa, which was held at the Laboratoire National d'Essais (LNE), Paris, France, from 2 to 4 June 1993. The scope of the seminar was to review the state of the art of pressure measurements in the 1 kPa to I GPa pressure range and to present innovative contributions by standards laboratories, universities and industry. The seminar was organized in six sessions: liquid-column manometers; piston gauge pressure standards; properties of liquids and gases relevant to pressure metrology; pressure transducers and transfer standards; pressure standard comparison (methods and results); dynamic pressure measurements. Each session opened with the presentation of a review paper on major requirements in that field and, at the end of the seminar, a general discussion was organized on the actual limits of accuracy of static and dynamic pressure measurements in fluid media, and the fundamental problems in pressure metrology between 1 kPa and 1 GPa. The seminar was attended by sixty scientists from twenty-four countries, all working in the field of pressure measurements. Forty-nine papers were presented. The participation of scientists from so many countries indicates the importance of pressure metrology from the scientific and industrial points of view. Most papers were presented by scientists from national standards laboratories, with eight papers from universities and four from industry. Eleven papers reported the results of cooperative work involving metrological institutions dealing with high pressure, generally national standards laboratories, an indication that scientific links are already well established at this level. Links are also strengthening between industry and standards laboratories. Although industrial participation at the seminar was relatively small, it was at a high level. This special issue of Metrologia brings together all the seminar papers accepted for publication after a careful review process controlled directly by the organizing committee of the seminar and the Metrologia editor. I feel that we have succeeded reasonably well. The papers published here focus on important achievements in pressure measurements and the main problems which the scientific community is working to resolve in the future. Various achievements are reported, ranging from a general improvement in accuracy to new devices and techniques. I would like to thank all those who helped with this seminar. First, the members of the organizing committee: Chairman of the CCM Medium Pressure Work ing Group, P Stuart, (NPL, UK); J Bonhoure (BIPM); V Borovkov (VNIIFTRI, Russia); C Ehrlich (NIST, USA); J Jager (PTB, Germany); J C Legras (LNE); Chairman of the CCM Low Pressure Working Group, C Tilford (NIST, USA); S Yamamoto (NRLM, Japan); R Wirniewski (WUT, Poland); not forgetting the institutions that allowed them to spend considerable time on the preparation and organization of the seminar. I extend my thanks to V E Bean (NIST, USA), A Ooiwa (NRLM, Japan), and A J Rostocki (WUT, Poland), who joined the organizing committee as guest editors and helped to see the papers presented at the seminar through the review process and into print. Many thanks are also due to A Bryden, Director of the Laboratoire National d'Essais, and to J C Legras of the LNE Pressure Laboratory, for hosting the seminar and for taking care of all practical problems. A special thanks to T J Quinn, Director of the Bureau International des Poids et Mesures, for his continuous support and encouragement in the preparation of the seminar. Grateful thanks to Desgranges et Huot, France, for their hospitality in Paris; and to D-H Instruments Co., USA, and Ruska Co., USA, which sponsored the seminar through their fmancial support for the publication of these Proceedings. A special mention must be made of D Blackburn, Metrologia editor, his assistant C Lawrence, and the administrative staff of the BIPM, for their valuable contribution. Last but not least, thanks to all participants who, through their work, have given us the opportunity to present the state of the art in pressure measurements and to evaluate future requirements. This experience will surely be repeated. Such international contacts inspire the dream of a better world where science and technology are at the service of humanity.

  8. Modeling Attitude towards Drug Treament: The Role of Internal Motivation, External Pressure, and Dramatic Relief

    PubMed Central

    Longshore, Douglas; Anglin, M. Douglas

    2009-01-01

    Motivation for change has historically been viewed as the crucial element affecting responsiveness to drug treatment. Various external pressures, such as legal coercion, may engender motivation in an individual previously resistant to change. Dramatic relief may be the change process that is most salient as individuals internalize such external pressures. Results of structural equation modeling on data from 465 drug users (58.9% male; 21.3% Black, 34.2% Hispanic/Latino, and 35.1% White) entering drug treatment indicated that internal motivation and external pressure significantly and positively predicted dramatic relief and that dramatic relief significantly predicted attitudes towards drug treatment: χ2=142.20, df=100, p<0.01; Robust Comparative Fit Index=0.97, Root Mean Squared Error of Approximation=0.03. These results indicate that when external pressure and internal motivation are high, dramatic relief is also likely to be high. When dramatic relief is high, attitudes towards drug treatment are likely to be positive. The findings indicate that interventions to get individuals into drug treatment should include processes that promote Dramatic Relief. Implications for addictions health services are discussed. PMID:18535908

  9. 49 CFR 195.132 - Design and construction of aboveground breakout tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.132 Design and... to withstand the internal pressure produced by the hazardous liquid to be stored therein and any...) and with internal vapor space pressures that are approximately atmospheric must be designed and...

  10. 49 CFR 195.132 - Design and construction of aboveground breakout tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.132 Design and... to withstand the internal pressure produced by the hazardous liquid to be stored therein and any...) and with internal vapor space pressures that are approximately atmospheric must be designed and...

  11. 49 CFR 195.132 - Design and construction of aboveground breakout tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.132 Design and... to withstand the internal pressure produced by the hazardous liquid to be stored therein and any...) and with internal vapor space pressures that are approximately atmospheric must be designed and...

  12. 49 CFR 195.132 - Design and construction of aboveground breakout tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.132 Design and... to withstand the internal pressure produced by the hazardous liquid to be stored therein and any...) and with internal vapor space pressures that are approximately atmospheric must be designed and...

  13. 49 CFR 195.132 - Design and construction of aboveground breakout tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.132 Design and... to withstand the internal pressure produced by the hazardous liquid to be stored therein and any...) and with internal vapor space pressures that are approximately atmospheric must be designed and...

  14. High-pressure protein crystallography of hen egg-white lysozyme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Hiroyuki; Nagae, Takayuki; Watanabe, Nobuhisa, E-mail: nobuhisa@nagoya-u.jp

    The crystal structure of hen egg-white lysozyme (HEWL) was analyzed under pressures of up to 950 MPa. The high pressure modified the conformation of the molecule and induced a novel phase transition in the tetragonal crystal of HEWL. Crystal structures of hen egg-white lysozyme (HEWL) determined under pressures ranging from ambient pressure to 950 MPa are presented. From 0.1 to 710 MPa, the molecular and internal cavity volumes are monotonically compressed. However, from 710 to 890 MPa the internal cavity volume remains almost constant. Moreover, as the pressure increases to 950 MPa, the tetragonal crystal of HEWL undergoes a phasemore » transition from P4{sub 3}2{sub 1}2 to P4{sub 3}. Under high pressure, the crystal structure of the enzyme undergoes several local and global changes accompanied by changes in hydration structure. For example, water molecules penetrate into an internal cavity neighbouring the active site and induce an alternate conformation of one of the catalytic residues, Glu35. These phenomena have not been detected by conventional X-ray crystal structure analysis and might play an important role in the catalytic activity of HEWL.« less

  15. Unified Static and Dynamic Recrystallization Model for the Minerals of Earth's Mantle Using Internal State Variable Model

    NASA Astrophysics Data System (ADS)

    Cho, H. E.; Horstemeyer, M. F.; Baumgardner, J. R.

    2017-12-01

    In this study, we present an internal state variable (ISV) constitutive model developed to model static and dynamic recrystallization and grain size progression in a unified manner. This method accurately captures temperature, pressure and strain rate effect on the recrystallization and grain size. Because this ISV approach treats dislocation density, volume fraction of recrystallization and grain size as internal variables, this model can simultaneously track their history during the deformation with unprecedented realism. Based on this deformation history, this method can capture realistic mechanical properties such as stress-strain behavior in the relationship of microstructure-mechanical property. Also, both the transient grain size during the deformation and the steady-state grain size of dynamic recrystallization can be predicted from the history variable of recrystallization volume fraction. Furthermore, because this model has a capability to simultaneously handle plasticity and creep behaviors (unified creep-plasticity), the mechanisms (static recovery (or diffusion creep), dynamic recovery (or dislocation creep) and hardening) related to dislocation dynamics can also be captured. To model these comprehensive mechanical behaviors, the mathematical formulation of this model includes elasticity to evaluate yield stress, work hardening in treating plasticity, creep, as well as the unified recrystallization and grain size progression. Because pressure sensitivity is especially important for the mantle minerals, we developed a yield function combining Drucker-Prager shear failure and von Mises yield surfaces to model the pressure dependent yield stress, while using pressure dependent work hardening and creep terms. Using these formulations, we calibrated against experimental data of the minerals acquired from the literature. Additionally, we also calibrated experimental data for metals to show the general applicability of our model. Understanding of realistic mantle dynamics can only be acquired once the various deformation regimes and mechanisms are comprehensively modeled. The results of this study demonstrate that this ISV model is a good modeling candidate to help reveal the realistic dynamics of the Earth's mantle.

  16. Essential ocean variables for global sustained observations of biodiversity and ecosystem changes.

    PubMed

    Miloslavich, Patricia; Bax, Nicholas J; Simmons, Samantha E; Klein, Eduardo; Appeltans, Ward; Aburto-Oropeza, Octavio; Andersen Garcia, Melissa; Batten, Sonia D; Benedetti-Cecchi, Lisandro; Checkley, David M; Chiba, Sanae; Duffy, J Emmett; Dunn, Daniel C; Fischer, Albert; Gunn, John; Kudela, Raphael; Marsac, Francis; Muller-Karger, Frank E; Obura, David; Shin, Yunne-Jai

    2018-04-05

    Sustained observations of marine biodiversity and ecosystems focused on specific conservation and management problems are needed around the world to effectively mitigate or manage changes resulting from anthropogenic pressures. These observations, while complex and expensive, are required by the international scientific, governance and policy communities to provide baselines against which the effects of human pressures and climate change may be measured and reported, and resources allocated to implement solutions. To identify biological and ecological essential ocean variables (EOVs) for implementation within a global ocean observing system that is relevant for science, informs society, and technologically feasible, we used a driver-pressure-state-impact-response (DPSIR) model. We (1) examined relevant international agreements to identify societal drivers and pressures on marine resources and ecosystems, (2) evaluated the temporal and spatial scales of variables measured by 100+ observing programs, and (3) analysed the impact and scalability of these variables and how they contribute to address societal and scientific issues. EOVs were related to the status of ecosystem components (phytoplankton and zooplankton biomass and diversity, and abundance and distribution of fish, marine turtles, birds and mammals), and to the extent and health of ecosystems (cover and composition of hard coral, seagrass, mangrove and macroalgal canopy). Benthic invertebrate abundance and distribution and microbe diversity and biomass were identified as emerging EOVs to be developed based on emerging requirements and new technologies. The temporal scale at which any shifts in biological systems will be detected will vary across the EOVs, the properties being monitored and the length of the existing time-series. Global implementation to deliver useful products will require collaboration of the scientific and policy sectors and a significant commitment to improve human and infrastructure capacity across the globe, including the development of new, more automated observing technologies, and encouraging the application of international standards and best practices. © 2018 The Authors. Global Change Biology Published by John Wiley & Sons Ltd.

  17. Thermodynamic properties of isomeric pentanols under elevated pressures determined by the acoustic method

    NASA Astrophysics Data System (ADS)

    Dzida, M.

    2008-02-01

    Three isomeric pentanols were studied: pentan-1-ol, 2-methyl-1-buta- nol, and 2-methyl-2-butanol. Isobaric heat capacities and internal pressure at pressures up to 100 MPa and temperatures ranging from 293 K to 318 K were determined by the acoustic method. In calculations the measured speeds of sound as function of temperature and pressure together with densities as function of temperature under atmospheric pressure and the literature isobaric heat capacities for the atmospheric pressure were used. To this end, the method, based on the suggestion of Davis and Gordon [1] was applied. The results obtained show that the effect of pressure on and the values of isobaric heat capacity and internal presure of 2-methyl-2-butanol is higher than that of pentan-1-ol, 2-methyl-1-butanol over the whole pressure range. That facilitates telling 2-methyl-2-butanol from pentan-1-ol and 2-methyl-1-butanol.

  18. Investigation of space shuttle vehicle 140C configuration orbiter (model 16-0) wheel well pressure loads in the Rockwell International 7.75 x 11 foot wind tunnel (OA143)

    NASA Technical Reports Server (NTRS)

    Mennell, R. C.

    1975-01-01

    Experimental aerodynamic investigations were conducted on a sting mounted .0405-scale representation of the 140C outer mold line space shuttle orbiter configuration in the Rockwell International 7.75 x 11.00 foot low speed wind tunnel. The primary test objectives were to define the orbiter wheel well pressure loading and its effects on landing gear thermal insulation and to investigate the pressure environment experienced by both the horizontal flight nose probe and air vent door probes. Steady state and dynamic pressure values were recorded in the orbiter nose gear well, left main landing gear well, horizontal flight nose probe, and both left and right air vent door probe. All steady state pressure levels were measured by Statham differential pressure transducers while dynamic pressure levels were recorded by Kulite high frequency response pressure sensors.

  19. Simply actuated closure for a pressure vessel - Design for use to trap deep-sea animals

    NASA Technical Reports Server (NTRS)

    Yayanos, A. A.

    1977-01-01

    A pressure vessel is described that can be closed by a single translational motion within 1 sec. The vessel is a key component of a trap for small marine animals and operates automatically on the sea floor. As the vessel descends to the sea floor, it is subjected both internally and externally to the high pressures of the deep sea. The mechanism for closing the pressure vessel on the sea floor is activated by the timed release of the ballast which was used to sink the trap. As it rises to the sea surface, the internal pressure of the vessel remains near the value present on the sea floor. The pressure vessel has been used in simulated ocean deployments and in the deep ocean (9500 m) with a 75%-85% retention of the deep-sea pressure. Nearly 100% retention of pressure can be achieved by using an accumulator filled with a gas.

  20. Review of Full-Scale Docking Seal Testing Capabilities

    NASA Technical Reports Server (NTRS)

    Dunlap, Patrick H., Jr.; Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.; Steinetz, Bruce M.

    2008-01-01

    NASA is developing a new docking system to support future space exploration missions to low-Earth orbit, the Moon, and Mars. This mechanism, called the Low Impact Docking System (LIDS), is designed to connect pressurized space vehicles and structures including the Crew Exploration Vehicle, International Space Station, and lunar lander. NASA Glenn Research Center (GRC) is playing a key role in developing the main interface seal for this new docking system. These seals will be approximately 147 cm (58 in.) in diameter. To evaluate the performance of the seals under simulated operating conditions, NASA GRC is developing two new test rigs: a non-actuated version that will be used to measure seal leak rates and an actuated test rig that will be able to measure both seal leak rates and loads. Both test rigs will be able to evaluate the seals under seal-on-seal or seal-on-plate configurations at temperatures from -50 to 50 C (-58 to 122 F) under operational and pre-flight checkout pressure gradients in both aligned and misaligned conditions.

  1. Effect of several geometric parameters on the static internal performance of three nonaxisymmetric nozzle concepts

    NASA Technical Reports Server (NTRS)

    Berrier, B. L.; Re, R. J.

    1979-01-01

    Effects of several geometric parameters on the internal performance of nonaxisymmetric convergent-divergent, single-ramp expansion, and wedge nozzles were investigated at nozzle pressure ratios up to approximately 10. In addition, two different thrust-vectoring schemes were investigated with the wedge nozzle. The results indicated that as with conventional round nozzles, peak nonaxisymmetric nozzle, internal performance occurred near the nozzle pressure ratio required for fully expanded exhaust flow. Nozzle sidewall length or area generally had little effect on the internal performance of the nozzles investigated.

  2. Maneuvering impact boring head

    DOEpatents

    Zollinger, W. Thor; Reutzel, Edward W.

    1998-01-01

    An impact boring head may comprise a main body having an internal cavity with a front end and a rear end. A striker having a head end and a tail end is slidably mounted in the internal cavity of the main body so that the striker can be reciprocated between a forward position and an aft position in response to hydraulic pressure. A compressible gas contained in the internal cavity between the head end of the striker and the front end of the internal cavity returns the striker to the aft position upon removal of the hydraulic pressure.

  3. Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

    PubMed

    Tonnelier, Alexandre; Lellouche, François; Bouchard, Pierre Alexandre; L'Her, Erwan

    2013-08-01

    Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. To evaluate the influence of nebulization and active humidification on the resistance of expiratory filters. A respiratory system analog was constructed using a test lung, an ICU ventilator, heated humidifiers, and a piezoelectric nebulizer. Humidifiers were connected to different types of circuits (unheated, mono-heated, new-generation and old-generation bi-heated). Five filter types were evaluated: electrostatic, heat-and-moisture exchanger, standard, specific, and internal heated high-efficiency particulate air [HEPA] filter. Baseline characteristics were obtained from each dry filter. Differential pressure measurements were carried out after 24 hours of continuous in vitro use for each condition, and after 24 hours of use with an old-generation bi-heated circuit without nebulization. While using unheated circuits, measurements had to be interrupted before 24 hours for all the filtering devices except the internal heated HEPA filter. The heat-and-moisture exchangers occluded before 24 hours with the unheated and mono-heated circuits. The circuit type, nebulization practice, and duration of use did not influence the internal heated HEPA filter resistance. Expiratory limb filtration is likely to induce several major adverse events. Expiratory filter resistance increase is due mainly to the humidification circuit type, rather than to nebulization. If filtration is mandatory while using an unheated circuit, a dedicated filter should be used for ≤ 24 hours, or a heated HEPA for a longer duration.

  4. A System to Measure Both Inner and Outer Car Tire Temperatures ``in situ''

    NASA Astrophysics Data System (ADS)

    Koštial, P.; Mokryšová, M.; Šišáková, J.; Mošková, Z.; Rusnáková, S.

    2009-02-01

    In the paper, a system for the complex analysis of the internal and external tire temperatures and pressure of sporty tires is presented. Tests were performed on the test circuit of a tire producer. The CTPA 05 measuring system (complex temperature-pressure analyzer) enables simultaneous measurements of the internal temperature and pressure in a passenger or sports tire. The experimentalist determines that the CTPA 05 can be used to measure independently the external temperature of the overcoat on the front wheel driving tires at three points. Measurements of both the internal tire temperature and pressure, as well as of the external tire temperature, are collected together with GPS (global position system) data. The system of measurement is fully automatic and contactless. The obtained results are in very good agreement with those obtained by independent methods.

  5. A Model Evaluation Data Set for the Tropical ARM Sites

    DOE Data Explorer

    Jakob, Christian

    2008-01-15

    This data set has been derived from various ARM and external data sources with the main aim of providing modelers easy access to quality controlled data for model evaluation. The data set contains highly aggregated (in time) data from a number of sources at the tropical ARM sites at Manus and Nauru. It spans the years of 1999 and 2000. The data set contains information on downward surface radiation; surface meteorology, including precipitation; atmospheric water vapor and cloud liquid water content; hydrometeor cover as a function of height; and cloud cover, cloud optical thickness and cloud top pressure information provided by the International Satellite Cloud Climatology Project (ISCCP).

  6. 46 CFR 154.407 - Cargo tank internal pressure head.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Equipment Cargo Containment Systems § 154.407 Cargo tank internal pressure head. (a) For the calculation..., resulting from the combined effects of gravity and dynamic accelerations of a full tank)=aβ Zβ Y; where: aβ=dimensionless acceleration relative to the acceleration of gravity resulting from gravitational and dynamic...

  7. New Horizons Tanzania, Ltd.--A Case of International HRD in Two Parts (Part One)

    ERIC Educational Resources Information Center

    Williams, Sandra L.; Hurley, Mark N.

    2017-01-01

    For international organizations in developing countries, operating across cultures can elicit varied perspectives on employee engagement and employee development. Performance pressure from a board of directors will also influence the human resource development emphasis of organization leaders. Varied perspectives and performance pressures place…

  8. Factors Relating to Student Grade Obsession: A Quantitative Correlational Study

    ERIC Educational Resources Information Center

    Thomas, Jacqueline

    2011-01-01

    The intense focus of students on grades attained in academia reflects a contemporary issue in higher education. The internal pressure that students experience regarding academics fuels student grade obsession. Researchers suggest that in addition to internal pressure, financial anxiety, the need to receive academic recognition and parental…

  9. A stepped pressure profile model for internal transport barriers

    NASA Astrophysics Data System (ADS)

    Hole, Matthew; Hudson, Stuart; Dewar, Robert

    2007-11-01

    B ∇x et al We develop a multiple interface variational model, comprising multiple Taylor-relaxed plasma regions separated by ideal MHD barriers. The magnetic field in each region is Beltrami, = μ, and the pressure constant. Between these regions the pressure, field strength, and rotational transform may have step changes at the ideal barrier. A principle motivation is the development of a mathematically rigorous ideal MHD model to describe intrinsically 3D equilibria, with nonzero internal pressure, using robust KAM surfaces as the barriers. As each region is locally relaxed however, such a model may also yield reasons for existence of internal transport barriers (ITBs). Focusing on the latter, we build on Hole Nuc. Fus. 47, pp746-753, 2007, which recently studied the stability of a two-interface periodic-cylinder configuration. In this work, we perform a stability scan over pressure and for a two-interface configuration with no jump in , and compare the characteristics of stable equilibria to those of ITB's.

  10. Influence of oxygen partial pressure on the microstructural and magnetic properties of Er-doped ZnO thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Wei-Bin; Li, Fei; Chen, Hong-Ming

    2015-06-15

    Er-doped ZnO thin films have been prepared by using inductively coupled plasma enhanced physical vapor deposition at different O{sub 2}:Ar gas flow ratio (R = 0:30, 1:30, 1:15, 1:10 and 1:6). The influence of oxygen partial pressure on the structural, optical and magnetic properties was studied. It is found that an appropriate oxygen partial pressure (R=1:10) can produce the best crystalline quality with a maximum grain size. The internal strain, estimated by fitting the X-ray diffraction peaks, varied with oxygen partial pressure during growth. PL measurements show that plenty of defects, especially zinc vacancy, exist in Er-doped ZnO films. Allmore » the samples show room-temperature ferromagnetism. Importantly, the saturation magnetization exhibits similar dependency on oxygen partial pressure with the internal strain, which indicates that internal strain has an important effect on the magnetic properties of Er-doped ZnO thin films.« less

  11. Collapse Pressure Analysis of Transversely Isotropic Thick-Walled Cylinder Using Lebesgue Strain Measure and Transition Theory

    PubMed Central

    Aggarwal, A. K.; Sharma, Richa; Sharma, Sanjeev

    2014-01-01

    The objective of this paper is to provide guidance for the design of the thick-walled cylinder made up of transversely isotropic material so that collapse of cylinder due to influence of internal and external pressure can be avoided. The concept of transition theory based on Lebesgue strain measure has been used to simplify the constitutive equations. Results have been analyzed theoretically and discussed numerically. From this analysis, it has been concluded that, under the influence of internal and external pressure, circular cylinder made up of transversely isotropic material (beryl) is on the safer side of the design as compared to the cylinders made up of isotropic material (steel). This is because of the reason that percentage increase in effective pressure required for initial yielding to become fully plastic is high for beryl as compared to steel which leads to the idea of “stress saving” that reduces the possibility of collapse of thick-walled cylinder due to internal and external pressure. PMID:24523632

  12. Fracture resistance of welded thick-walled high-pressure vessels in power plants. Report No. 2. Approach to evaluating static strength

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorynin, I.V.; Filatov, V.M.; Ignatov, V.A.

    1986-07-01

    The authors examine data on the effect of defects on the fracture resistance of high-pressure vessels and their models obtained within the framework of the HSST program. Results of internal-pressure tests of two types of vessels with a wall thickness of 152 mm made from forgings of steels SA508 and SA533, as well as small vessels with a wall thickness of 11.5 and 23mm made of steel SA533 are shown. The authors state that testing thick-walled welded high-pressure vessels and thin-walled vessels with surface defects of different sizes has demonstrated that there are substantial static-strength reserves in structures designed bymore » existing domestic and foreign standards on the strength of power-plant equipment. A correction was proposed for the presently used method of calculating the resistance of highpressure vessels to brittle fracture that allows for the dimensions of the defects in relation to the type of vessel, the manufacturing technology, and the method of inspection.« less

  13. Atmospheric Dynamics on Venus, Jupiter, and Saturn: An Observational and Analytical Study

    NASA Technical Reports Server (NTRS)

    Bridger, Alison; Magalhaes, Julio A.; Young, Richard E.

    2000-01-01

    Determining the static stability of Jupiter's atmosphere below the visible cloud levels is important for understanding the dynamical modes by which energy and momentum are transported through Jupiter's deep troposphere. The Galileo Probe Atmospheric Structure Investigation (ASI) employed pressure and temperature sensors to directly measure these state variables during the parachute-descent phase, which started at a pressure (p) of 0.4 bars and ended at p= 22 bars. The internal temperature of the probe underwent large temperature fluctuations which significantly exceeded design specifications. Corrections for these anomalous interior temperatures have been evaluated based on laboratory data acquired after the mission using the flight spare hardware. The corrections to the pressure sensor readings was particularly large and the uncertainties in the atmospheric pressures derived from the p sensor measurements may still be significant. We have sought to estimate the formal uncertainties in the static stability derived from the p and T sensor measurements directly and to devise means of assessing the static stability of Jupiter's atmosphere which do not rely on the p sensor data.

  14. Device for determining carbon activity through pressure

    DOEpatents

    Roche, Michael F.

    1976-01-01

    A hollow iron capsule of annular shape having an interior layer of Fe.sub.0.947 0 and a near absolute internal vacuum is submersed within a molten metal with the inner chamber of the capsule connected to a pressure sensor. Carbon present in the molten metal diffuses through the capsule wall and reacts with the Fe.sub.0.947 0 layer to generate a CO.sub.2 --CO gas mixture within the internal chamber. The total absolute pressure of the gas measured by the pressure sensor is directly proportional to the carbon activity of the molten metal.

  15. High temperature aqueous stress corrosion testing device

    DOEpatents

    Bornstein, A.N.; Indig, M.E.

    1975-12-01

    A description is given of a device for stressing tensile samples contained within a high temperature, high pressure aqueous environment, thereby permitting determination of stress corrosion susceptibility of materials in a simple way. The stressing device couples an external piston to an internal tensile sample via a pull rod, with stresses being applied to the sample by pressurizing the piston. The device contains a fitting/seal arrangement including Teflon and weld seals which allow sealing of the internal system pressure and the external piston pressure. The fitting/seal arrangement allows free movement of the pull rod and the piston.

  16. Two methods to simulate intrapulpal pressure: effects upon bonding performance of self-etch adhesives.

    PubMed

    Feitosa, V P; Gotti, V B; Grohmann, C V; Abuná, G; Correr-Sobrinho, L; Sinhoreti, M A C; Correr, A B

    2014-09-01

    To evaluate the effects of two methods to simulate physiological pulpal pressure on the dentine bonding performance of two all-in-one adhesives and a two-step self-etch silorane-based adhesive by means of microtensile bond strength (μTBS) and nanoleakage surveys. The self-etch adhesives [G-Bond Plus (GB), Adper Easy Bond (EB) and silorane adhesive (SIL)] were applied to flat deep dentine surfaces from extracted human molars. The restorations were constructed using resin composites Filtek Silorane or Filtek Z350 (3M ESPE). After 24 h using the two methods of simulated pulpal pressure or no pulpal pressure (control groups), the bonded teeth were cut into specimens and submitted to μTBS and silver uptake examination. Results were analysed with two-way anova and Tukey's test (P < 0.05). Both methods of simulated pulpal pressure led statistically similar μTBS for all adhesives. No difference between control and pulpal pressure groups was found for SIL and GB. EB led significant drop (P = 0.002) in bond strength under pulpal pressure. Silver impregnation was increased after both methods of simulated pulpal pressure for all adhesives, and it was similar between the simulated pulpal pressure methods. The innovative method to simulate pulpal pressure behaved similarly to the classic one and could be used as an alternative. The HEMA-free one-step and the two-step self-etch adhesives had acceptable resistance against pulpal pressure, unlike the HEMA-rich adhesive. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  17. Correlation of combustor acoustic power levels inferred from internal fluctuating pressure measurements

    NASA Technical Reports Server (NTRS)

    Vonglahn, U. H.

    1978-01-01

    Combustion chamber acoustic power levels inferred from internal fluctuating pressure measurements are correlated with operating conditions and chamber geometries over a wide range. The variables include considerations of chamber design (can, annular, and reverse-flow annular) and size, number of fuel nozzles, burner staging and fuel split, airflow and heat release rates, and chamber inlet pressure and temperature levels. The correlated data include those obtained with combustion component development rigs as well as engines.

  18. Performance Evaluation of the International Space Station Flow Boiling and Condensation Experiment (FBCE) Test Facility

    NASA Technical Reports Server (NTRS)

    Hasan, Mohammad; Balasubramaniam, R.; Nahra, Henry; Mackey, Jeff; Hall, Nancy; Frankenfield, Bruce; Harpster, George; May, Rochelle; Mudawar, Issam; Kharangate, Chirag R.; hide

    2016-01-01

    A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.

  19. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland

    2014-01-01

    Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. All four tested devices passed the validation process. The mean differences between the device and mercury readings were: -1.8±5.1 mmHg and -0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and -1.2±4.3 mmHg for the Omron HEM-7420 device; -0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly.

  20. Plantar Pressure Anomalies After Open Reduction With Internal Fixation of High-Grade Calcaneal Fractures.

    PubMed

    Hetsroni, Iftach; Ben-Sira, David; Nyska, Meir; Ayalon, Moshe

    2014-07-01

    Plantar pressure abnormalities after open reduction with internal fixation (ORIF) of intra-articular calcaneal fractures have been observed previously, but high-grade fractures were not selectively investigated and follow-up times were shorter than 2 years. The purpose of this study was to characterize plantar pressure anomalies in patients with exclusively high-grade calcaneal fractures after ORIF with a minimum 2 years of follow-up, and to test the association between plantar pressure distribution and the clinical outcome. The orthopaedic registry was reviewed to identify patients with isolated high-grade calcaneal fractures (Sanders types III-IV) who were operated on and had a minimum 2 years of follow-up. Sixteen patients were evaluated. Mean age was 47 years and follow-up was between 2 and 6 years. The Pedar-Mobile system was used to measure 3 loading and 3 temporal variables and compare these between the operated and the uninjured limbs. Mean American Orthopaedic Foot and Ankle Society (AOFAS) score was 76 ± 7 at latest follow-up. Bohler's angle was 5 ± 8 degrees before surgery and 25 ± 7 degrees at latest follow-up. Stance was shorter in operated limbs (P = .001). Timing of the peak of pressure was delayed in operated limbs under the hallux and the second toe (P ≤ .03). Peak pressure, force time integral, and pressure time integral were increased under the lateral midfoot (P ≤ .03) and decreased under the second metatarsal (P ≤ .03). Force time integral was decreased under the first metatarsal (P = .02) and under the hallux and the lateral toes (P ≤ .05). Increased loading under the lateral midfoot and decreased loading under the lateral toes were correlated with poorer clinical outcome (r = -.53, P < .05, and r = .63, P < .01, respectively). Side-to-side plantar pressure mismatch persisted at more than 2 years after ORIF of high-grade calcaneal fractures performed via lateral approach, despite improvement of Bohler's angle. This was characterized by shortened stance phase, delayed timing of peak of pressure under the hallux and second toe, lateral load shift at the midfoot, and decreased toe pressures in operated limbs. Since loading abnormalities were correlated with the clinical outcome, modifications in treatment strategy that can improve foot loading may be desirable in these cases. Level III, case control. © The Author(s) 2014.

  1. A pressure consistent bridge correction of Kovalenko-Hirata closure in Ornstein-Zernike theory for Lennard-Jones fluids by apparently adjusting sigma parameter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebato, Yuki; Miyata, Tatsuhiko, E-mail: miyata.tatsuhiko.mf@ehime-u.ac.jp

    Ornstein-Zernike (OZ) integral equation theory is known to overestimate the excess internal energy, U{sup ex}, pressure through the virial route, P{sub v}, and excess chemical potential, μ{sup ex}, for one-component Lennard-Jones (LJ) fluids under hypernetted chain (HNC) and Kovalenko-Hirata (KH) approximatons. As one of the bridge correction methods to improve the precision of these thermodynamic quantities, it was shown in our previous paper that the method to apparently adjust σ parameter in the LJ potential is effective [T. Miyata and Y. Ebato, J. Molec. Liquids. 217, 75 (2016)]. In our previous paper, we evaluated the actual variation in the σmore » parameter by using a fitting procedure to molecular dynamics (MD) results. In this article, we propose an alternative method to determine the actual variation in the σ parameter. The proposed method utilizes a condition that the virial and compressibility pressures coincide with each other. This method can correct OZ theory without a fitting procedure to MD results, and possesses characteristics of keeping a form of HNC and/or KH closure. We calculate the radial distribution function, pressure, excess internal energy, and excess chemical potential for one-component LJ fluids to check the performance of our proposed bridge function. We discuss the precision of these thermodynamic quantities by comparing with MD results. In addition, we also calculate a corrected gas-liquid coexistence curve based on a corrected KH-type closure and compare it with MD results.« less

  2. 46 CFR 154.408 - Cargo tank external pressure load.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... minimum internal pressure (maximum vacuum), and the maximum external pressure to which any portion of the... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo tank external pressure load. 154.408 Section 154... Equipment Cargo Containment Systems § 154.408 Cargo tank external pressure load. For the calculation...

  3. Effect of Salinity and Alkalinity on Luciobarbus capito Gill Na+/K+-ATPase Enzyme Activity, Plasma Ion Concentration, and Osmotic Pressure

    PubMed Central

    2016-01-01

    We evaluated the individual and combined effects of salinity and alkalinity on gill Na+/K+-ATPase enzyme activity, plasma ion concentration, and osmotic pressure in Luciobarbus capito. Increasing salinity concentrations (5, 8, 11, and 14 g/L) were associated with an initial increase and then decrease in L. capito gill Na+/K+-ATPase activity. Activity was affected by the difference between internal and external Na+ ion concentrations and osmotic pressure (P < 0.05). Both plasma ion (Na+, K+, and Cl−) concentration and osmotic pressure increased significantly (P < 0.05). An increase in alkalinity (15, 30, 45, and 60 mM) caused a significant increase in plasma K+ and urea nitrogen concentrations (P < 0.05) but had no effect on either plasma osmotic pressure or gill filament ATPase activity. In the two-factor experiment, the saline-alkaline interaction caused a significant increase in plasma ion (Na+, Cl−, and urea nitrogen) and osmotic pressure (P < 0.05). Variance analysis revealed that salinity, alkalinity, and their interaction significantly affected osmotic pressure, with salinity being most affected, followed by alkalinity, and their interaction. Gill filament ATPase activity increased at first and then decreased; peak values were observed in the orthogonal experiment group at a salinity of 8 g/L and alkalinity of 30 mM. PMID:27981049

  4. High blood Pressure in children and its correlation with three definitions of obesity in childhood

    PubMed Central

    de Moraes, Leonardo Iezzi; Nicola, Thaís Coutinho; de Jesus, Julyanna Silva Araújo; Alves, Eduardo Roberty Badiani; Giovaninni, Nayara Paula Bernurdes; Marcato, Daniele Gasparini; Sampaio, Jéssica Dutra; Fuly, Jeanne Teixeira Bessa; Costalonga, Everlayny Fiorot

    2014-01-01

    Background Several authors have correlated the increase of cardiovascular risk with the nutritional status, however there are different criteria for the classification of overweight and obesity in children. Objectives To evaluate the performance of three nutritional classification criteria in children, as definers of the presence of obesity and predictors of high blood pressure in schoolchildren. Methods Eight hundred and seventeen children ranging 6 to 13 years old, enrolled in public schools in the municipality of Vila Velha (ES) were submitted to anthropometric evaluation and blood pressure measurement. The classification of the nutritional status was established by two international criteria (CDC/NCHS 2000 and IOTF 2000) and one Brazilian criterion (Conde e Monteiro 2006). Results The prevalence of overweight was higher when the criterion of Conde e Monteiro (27%) was used, and inferior by the IOTF (15%) criteria. High blood pressure was observed in 7.3% of children. It was identified a strong association between the presence of overweight and the occurrence of high blood pressure, regardless of the test used (p < 0.001). The test showing the highest sensitivity in predicting elevated BP was the Conde e Monteiro (44%), while the highest specificity (94%) and greater overall accuracy (63%), was the CDC criterion. Conclusions The prevalence of overweight in Brazilian children is higher when using the classification criterion of Conde e Monteiro, and lower when the criterion used is IOTF. The Brazilian classification criterion proved to be the most sensitive predictor of high BP risk in this sample. PMID:24676372

  5. Internal cooling circuit for gas turbine bucket

    DOEpatents

    Hyde, Susan Marie; Davis, Richard Mallory

    2005-10-25

    In a gas turbine bucket having a shank portion and an airfoil portion having leading and trailing edges and pressure and suction sides, an internal cooling circuit, the internal cooling circuit having a serpentine configuration including plural radial outflow passages and plural radial inflow passages, and wherein a coolant inlet passage communicates with a first of the radial outflow passages along the trailing edge, the first radial outflow passage having a plurality of radially extending and radially spaced elongated rib segments extending between and connecting the pressure and suction sides in a middle region of the first passage to prevent ballooning of the pressure and suction sides at the first radial outflow passage.

  6. Validation of the Konsung QD217A for clinical use and self-measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye

    2015-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor Konsung QD217A for home BP monitoring according to the European Society of Hypertension International Protocol revision 2010. Three trained observers validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using a standard mercury sphygmomanometer and the Konsung QD217A device. A total of 99 pairs of comparisons were obtained from 33 participants. The QD217A device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10 and 15 mmHg was 70/99, 92/99 and 96/99, respectively, for SBP and 80/99, 94/99 and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. A total of 27 and 31 participants for SBP and DBP, respectively, showed at least two of the three device-observers differences within 5 mmHg (required≥24). The number of participants without device-observer difference within 5 mmHg was one for SBP and one for DBP (required≤3). The Konsung upper arm BP monitor QD217A has passed the International Protocol requirements and it can be recommended for clinical use and self-measurement in adults. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

  7. Internal performance of two nozzles utilizing gimbal concepts for thrust vectoring

    NASA Technical Reports Server (NTRS)

    Berrier, Bobby L.; Taylor, John G.

    1990-01-01

    The internal performance of an axisymmetric convergent-divergent nozzle and a nonaxisymmetric convergent-divergent nozzle, both of which utilized a gimbal type mechanism for thrust vectoring was evaluated in the Static Test Facility of the Langley 16-Foot Transonic Tunnel. The nonaxisymmetric nozzle used the gimbal concept for yaw thrust vectoring only; pitch thrust vectoring was accomplished by simultaneous deflection of the upper and lower divergent flaps. The model geometric parameters investigated were pitch vector angle for the axisymmetric nozzle and pitch vector angle, yaw vector angle, nozzle throat aspect ratio, and nozzle expansion ratio for the nonaxisymmetric nozzle. All tests were conducted with no external flow, and nozzle pressure ratio was varied from 2.0 to approximately 12.0.

  8. Effect of facility background gases on internal erosion of the 30-cm Hg ion thruster

    NASA Technical Reports Server (NTRS)

    Rawlin, V. K.; Mantenieks, M. A.

    1978-01-01

    Sputtering erosion of the upstream side of the molybdenum screen grid by discharge chamber ions in mercury bombardment thrusters was considered. Data which revealed that the screen grid erosion was very sensitive to the partial pressure of certain background gases in the space simulation vacuum facility were presented along with results of tests conducted to evaluate this effect. It is shown from estimates of the screen grid erosion in space that adequate lifetime for proposed missions exists.

  9. Study on interfacial stability and internal flow of a droplet levitated by ultrasonic wave.

    PubMed

    Abe, Yutaka; Yamamoto, Yuji; Hyuga, Daisuke; Awazu, Shigeru; Aoki, Kazuyoshi

    2009-04-01

    For a microgravity environment, new and high-quality material is expected to be manufactured. However, the effect of surface instability and the internal flow become significant when the droplet becomes large. Elucidation of internal flow and surface instability on a levitated droplet is required for the quality improvement of new material manufacturing in a microgravity environment. The objectives of this study are to clarify the interfacial stability and internal flow of a levitated droplet. Surface instability and internal flow are investigated with a large droplet levitated by the ultrasonic acoustic standing wave. The experiment with a large droplet is conducted both under normal gravity and microgravity environments. In the experiment, at first, the characteristics of the levitated droplet are investigated; that is, the relationships among the levitated droplet diameter, the droplet aspect ratio, the displacement of the antinode of the standing wave, and the sound pressure are experimentally measured. As a result, it is clarified that the levitated droplet tends to be located at an optimal position with an optimal shape and diameter. Second, the border condition between the stable and the unstable levitation of the droplet is evaluated by using the existing stability theory. The experimental results qualitatively agree with the theory. It is suggested that the stability of the droplet can be evaluated with the stability theory. Finally, multidimensional visual measurement is conducted to investigate the internal flow structure in a levitated droplet. It is suggested that complex flow with the vortex is generated in the levitated droplet. Moreover, the effect of physical properties of the test fluid on the internal flow structure of the levitated droplet is investigated. As a result, the internal flow structure of the levitated droplet is affected by the surface tension and viscosity.

  10. Test Plan for the Boiling Water Reactor Dry Cask Simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durbin, Samuel; Lindgren, Eric R.

    The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis . These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing themore » internal convection through greater canister helium pressure. These same vertical, canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and below-ground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of above-ground and below-ground canistered dry cask systems. The purpose of the investigation described in this report is to produce a data set that can be used to test the validity of the assumptions associated with the calculations presently used to determine steady-state cladding temperatures in modern vertical, canistered dry cask systems. The BWR cask simulator (BCS) has been designed in detail for both the above-ground and below-ground venting configurations. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure (MAWP) rating of 24 bar at 400 deg C. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly is being deployed inside of a representative storage basket and cylindrical pressure vessel that represents the canister. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. Various configurations of outer concentric ducting will be used to mimic conditions for above and below-ground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. Of particular interest is the evaluation of the effect of increased helium pressure on allowable heat load and the effect of simulated wind on a simplified below ground vent configuration. While incorporating the best available information, this test plan is subject to changes due to improved understanding from modeling or from as-built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.« less

  11. Pilot Emergency Tutoring System for F-4 Aircraft Fuel System Malfunction Using Means-Ends Analysis

    DTIC Science & Technology

    1990-06-01

    pulled , and wing transfer pressure is normal. What operator do you choose? For example: type look_at INDICATOR for looked_at(INDICATOR) type set...cb internal wing transfer is pulled , and wing transfer pressure is normal. What operator do you choose? For example: type look_at INDICATOR for...at, external transfer is off, internal wing transfer is stop trans, refuel probe is extended, cb internal wing transfer is pulled ,and wing

  12. "Deflategate": Time, Temperature, and Moisture Effects on Football Pressure

    NASA Astrophysics Data System (ADS)

    Blumenthal, Jack; Beljak, Lauren; Macatangay, Dahlia-Marie; Helmuth-Malone, Lilly; McWilliams, Catharina; Raptis, Sofia

    2016-09-01

    In a recent paper in TPT, DiLisi and Rarick used the National Football League "Deflategate" controversy to introduce to physics students the physics of a bouncing ball. In this paper, we measure and analyze the environmental effects of time, ambient temperature, and moisture on the internal pressure of an NFL football. We focus on the rate of pressure recovery that occurs when a cold football (either wet or dry) is returned to the warm locker room environment where the pressure was initially measured. Both studies stem from the so-called NFL "Deflategate" controversy in which footballs that initially met a minimum internal pressure requirement were rechecked at halftime of the AFC Championship game, and in some cases were reported to have fallen below the minimum pressure requirement. The question is whether the pressure changes were due to environmental exposure or rather to some air being released from the balls, or both.

  13. Design and Test of Low-Profile Composite Aerospace Tank Dome

    NASA Technical Reports Server (NTRS)

    Ahmed, R.

    1999-01-01

    This report summarizes the design, analysis, manufacture, and test of a subscale, low-profile composite aerospace dome under internal pressure. A low-profile dome has a radius-to-height ratio greater than the square root of two. This effort demonstrated that a low-profile composite dome with a radius-to-height ratio of three was a feasible design and could adequately withstand the varying stress states resulting from internal pressurization. Test data for strain and displacement versus pressure are provided to validate the design.

  14. 77 FR 54926 - Certain Seamless Carbon and Alloy Steel; Standard, Line, and Pressure Pipe From Germany

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-709 (Third Review)] Certain Seamless Carbon and Alloy Steel; Standard, Line, and Pressure Pipe From Germany Determination On the basis of the record \\1\\ developed in the subject five-year review, the United States International Trade Commission...

  15. 40 CFR 63.7741 - What are the installation, operation, and maintenance requirements for my monitors?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Pollutants for Iron and Steel Foundries Continuous Compliance Requirements § 63.7741 What are the... eliminates pulsating pressure, vibration, and internal and external corrosion. (ii) Use a gauge with a... minimizes or eliminates pulsating pressure, vibration, and internal and external corrosion. (ii) Use a gauge...

  16. The Politics of Testing in South Africa

    ERIC Educational Resources Information Center

    Chisholm, Linda; Wildeman, Russell

    2013-01-01

    This article considers the politics of adoption of a testing regime in South Africa. While the broad features of this regime are similar to those in developed countries, there are features specific to the South African context. These emerge from a combination of external and internal pressures. External pressures derive from international testing…

  17. An Examination of Psychosocial Correlates of Eating Disorders among Female Collegiate Athletes

    ERIC Educational Resources Information Center

    Petrie, Trent A.; Greenleaf, Christy; Reel, Justine J.; Carter, Jennifer E.

    2009-01-01

    With female collegiate athletes, we examined the relationship of eating pathology to body image concerns, weight pressures, sociocultural internalization, and mood state. Multivariate analyses revealed that the symptomatic and eating disorder groups were similar on seven of eight weight pressures, three of four mood states, on internalization, and…

  18. Effects of Buckling Knockdown Factor, Internal Pressure and Material on the Design of Stiffened Cylinders

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Hilburger, Mark W.; Chunchu, Prasad B.

    2010-01-01

    A design study was conducted to investigate the effect shell buckling knockdown factor (SBKF), internal pressure and aluminum alloy material selection on the structural weight of stiffened cylindrical shells. Two structural optimization codes were used for the design study to determine the optimum minimum-weight design for a series of design cases, and included an in-house developed genetic algorithm (GA) code and PANDA2. Each design case specified a unique set of geometry, material, knockdown factor combinations and loads. The resulting designs were examined and compared to determine the effects of SBKF, internal pressure and material selection on the acreage design weight and controlling failure mode. This design study shows that use of less conservative SBKF values, including internal pressure, and proper selection of material alloy can result in significant weight savings for stiffened cylinders. In particular, buckling-critical cylinders with integrally machined stiffener construction can benefit from the use of thicker plate material that enables taller stiffeners, even when the stiffness, strength and density properties of these materials appear to be inferior.

  19. Deformation of Cases in High Capacitance Value Wet Tantalum Capacitors under Environmental Stresses

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2016-01-01

    Internal gas pressure in hermetic wet tantalum capacitors is created by air, electrolyte vapor, and gas generated by electrochemical reactions at the electrodes. This pressure increases substantially with temperature and time of operation due to excessive leakage currents. Deformation of the case occurs when the internal pressure exceeds pressure of the environments and can raise significantly when a part operates in space. Contrary to the cylinder case wet tantalum capacitors that have external sealing by welding and internal sealing provided by the Teflon bushing and crimping of the case, no reliable internal sealing exists in the button case capacitors. Single seal design capacitors are used for high capacitance value wet tantalum capacitors manufactured per DLA L&M drawings #04003, 04005, and 10011, and require additional analysis to assure their reliable application in space systems. In this work, leakage currents and case deformation of button case capacitors were measured during different environmental test conditions. Recommendations for derating, screening and qualification testing are given. This work is a continuation of a series of NEPP reports related to quality and reliability of wet tantalum capacitors.

  20. Comparative thermal analysis of alternate Cryogenic Fluid Management Experiment (CFME) configurations

    NASA Technical Reports Server (NTRS)

    Merino, F.; Oneill, R. F.

    1980-01-01

    The Cryogenic Fluid Management Experiment (CFME) was analyzed to assess the feasibility and advisability of deleting the vapor cooled shield (VCS) from the baseline CFME insulation and pressure control system. Two alternate concepts of CFME insulation and pressure control, neither of which incorporated the VCS, were investigated. The first concept employed a thermodynamic vent system (TVS) to throttle the flow through an internal wall mounted heat exchanger (HX) within the pressure vessel to decrease boiloff and pressure rise rate, while the second concept utilized a TVS without an internal heat exchanger. Only the first concept was viable. Its performance was assessed for a seven day mission and found to be satisfactory. It was also concluded that VCS development costs would be greater than for an internal HX installation. Based upon the above comparisons, the HX was recommended as a replacement for the VCS.

  1. Bench evaluation: three face-shield CPR barrier devices.

    PubMed

    Simmons, M; Deao, D; Moon, L; Peters, K; Cavanaugh, S

    1995-06-01

    Due to the fear of disease transmission, the practice of mouth-to-mouth (M-M) rescue breathing is rarely performed; to address this concern, many types of CPR barrier devices have been developed. These include bag-valve-mask devices, mouth-to-mask devices, and face shields (FS). The purpose of this study was to measure the volumes delivered during mouth-to-face shield (M-FS) breathing, to measure the back pressure and calculate the resistance to flow through their 1-way valves, and to test for backward leak of gas through the valves. Three FS brands were evaluated: Kiss of Life (KOL), MicroSHIELD (Micro) and Res-Cue Key (RCK). Volume delivered during M-M and M-FS breathing was evaluated by 10 rescuers who used the devices while performing rescue breathing on a CPR mannequin. Back pressure was measured and resistance calculated by directing airflow through the 1-way valves. Backward leak was evaluated by measuring the O2 concentration at the rescuer side of the valve while 100% O2 was directed toward the patient side of the valve. Differences among the brands were evaluated using analysis of variance. The mean (SD) values for volumes in L were: M-M 1.00 (0.25), Micro 0.77 (0.20), RCK 0.64 (0.10), and KOL 0.24 (0.11). Mean values for back pressure in cm H2O at 50 L/min were Micro 16.7 (1.29), KOL 7.22 (0.13), and RCK 2.15 (0.16). Significant backward leak only occurred with RCK. Not one of the FSs tested met all of the requirements suggested by the American Heart Association and by the International Standards Organization.

  2. Low internal pressure in femtoliter water capillary bridges reduces evaporation rates.

    PubMed

    Cho, Kun; Hwang, In Gyu; Kim, Yeseul; Lim, Su Jin; Lim, Jun; Kim, Joon Heon; Gim, Bopil; Weon, Byung Mook

    2016-03-01

    Capillary bridges are usually formed by a small liquid volume in a confined space between two solid surfaces. They can have a lower internal pressure than the surrounding pressure for volumes of the order of femtoliters. Femtoliter capillary bridges with relatively rapid evaporation rates are difficult to explore experimentally. To understand in detail the evaporation of femtoliter capillary bridges, we present a feasible experimental method to directly visualize how water bridges evaporate between a microsphere and a flat substrate in still air using transmission X-ray microscopy. Precise measurements of evaporation rates for water bridges show that lower water pressure than surrounding pressure can significantly decrease evaporation through the suppression of vapor diffusion. This finding provides insight into the evaporation of ultrasmall capillary bridges.

  3. High-pressure needle interface for thermoplastic microfluidics.

    PubMed

    Chen, C F; Liu, J; Hromada, L P; Tsao, C W; Chang, C C; DeVoe, D L

    2009-01-07

    A robust and low dead volume world-to-chip interface for thermoplastic microfluidics has been developed. The high pressure fluidic port employs a stainless steel needle inserted into a mating hole aligned to an embedded microchannel, with an interference fit used to increase pressure resistance. Alternately, a self-tapping threaded needle screwed into a mating hole is also demonstrated. In both cases, the flat bottom needle ports seat directly against the microchannel substrate, ensuring low interfacial dead volumes. Low dispersion is observed for dye bands passing the interfaces. The needle ports offer sufficient pull-out forces for applications such as liquid chromatography that require high internal fluid pressures, with the epoxy-free interfaces compatible with internal microchannel pressures above 40 MPa.

  4. Numerical simulation of abutment pressure redistribution during face advance

    NASA Astrophysics Data System (ADS)

    Klishin, S. V.; Lavrikov, S. V.; Revuzhenko, A. F.

    2017-12-01

    The paper presents numerical simulation data on the abutment pressure redistribution in rock mass during face advance, including isolines of maximum shear stress and pressure epures. The stress state of rock in the vicinity of a breakage heading is calculated by the finite element method using a 2D nonlinear model of a structurally heterogeneous medium with regard to plasticity and internal self-balancing stress. The thus calculated stress field is used as input data for 3D discrete element modeling of the process. The study shows that the abutment pressure increases as the roof span extends and that the distance between the face breast and the peak point of this pressure depends on the elastoplastic properties and internal self-balancing stress of a rock medium.

  5. Fractography and mechanisms of environmentally enhanced fatigue crack propagation of a reactor pressure vessel steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torronen, K.; Kemppainen, M.

    1981-10-01

    This paper describes the findings and interpretations of the fractographic survey conducted for the International Cyclic Crack Growth Rate (ICCGR) cooperative group round-robin specimens. Specimens of A533B pressure vessel steel were tested at several laboratories in the United States and elsewhere with the same nominal test parameters. A rather wide scatter of the results was found. A fractographic and metallographic survey was carried out in order to clarify the scatter and to evaluate the micromechanism of the crack growth. The fractographic findings are reported in detail and correlated to the crack growth behavior. A hydrogen-assisted crack propagation mechanism based onmore » the fractography is proposed and applied to the observed crack growth behavior.« less

  6. Comorbidity of internal derangement of the temporomandibular joint and silent dysfunction of the cervical spine.

    PubMed

    Stiesch-Scholz, M; Fink, M; Tschernitschek, H

    2003-04-01

    The aim of this evaluation was to examine correlations between internal derangement of the temporomandibular joint (TMJ) and cervical spine disorder (CSD). A prospective controlled clinical study was carried out. Thirty patients with signs and symptoms of internal derangement but without any subjective neck problems and 30 age- and gender-matched control subjects without signs and symptoms of internal derangement were examined. The investigation of the temporomandibular system was carried out using a 'Craniomandibular Index'. Afterwards an examiner-blinded manual medical investigation of the craniocervical system was performed. This included muscle palpation of the cervical spine and shoulder girdle as well as passive movement tests of the cervical spine, to detect restrictions in the range of movement as well as segmental intervertebral dysfunction. The internal derangement of the TMJ was significantly associated with 'silent' CSD (t-test, P < 0.05). Patients with raised muscle tenderness of the temporomandibular system exhibited significantly more often pain on pressure of the neck muscles than patients without muscle tenderness of the temporomandibular system (t-test, P < 0.05). As a result of the present study, for patients with internal derangement of the TMJ an additional examination of the craniocervical system should be recommended.

  7. Maneuvering impact boring head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zollinger, W.T.; Reutzel, E.W.

    An impact boring head may comprise a main body having an internal cavity with a front end and a rear end. A striker having a head end and a tail end is slidably mounted in the internal cavity of the main body so that the striker can be reciprocated between a forward position and an aft position in response to hydraulic pressure. A compressible gas contained in the internal cavity between the head end of the striker and the front end of the internal cavity returns the striker to the aft position upon removal of the hydraulic pressure. 8 figs.

  8. Maneuvering impact boring head

    DOEpatents

    Zollinger, W.T.; Reutzel, E.W.

    1998-08-18

    An impact boring head may comprise a main body having an internal cavity with a front end and a rear end. A striker having a head end and a tail end is slidably mounted in the internal cavity of the main body so that the striker can be reciprocated between a forward position and an aft position in response to hydraulic pressure. A compressible gas contained in the internal cavity between the head end of the striker and the front end of the internal cavity returns the striker to the aft position upon removal of the hydraulic pressure. 8 figs.

  9. 49 CFR 179.500-14 - Test of tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-14 Test of tanks. (a) After heat-treatment, tanks shall be subjected to hydrostatic tests in a water... subjected previously to internal pressure greater than 90 percent of the marked test pressure. Each tank shall be tested to a pressure at least equal to the marked test pressure of the tank. Pressure shall be...

  10. 49 CFR 179.300-16 - Tests of tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) [Reserved] (b) After all fittings have been installed, each tank shall be subjected to interior air pressure... methods. No tank shall have been subjected previously to internal pressure within 100 pounds of the test pressure. Each tank shall be tested to the pressure prescribed in § 179.301. Pressure shall be maintained...

  11. 49 CFR 179.300-16 - Tests of tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) [Reserved] (b) After all fittings have been installed, each tank shall be subjected to interior air pressure... methods. No tank shall have been subjected previously to internal pressure within 100 pounds of the test pressure. Each tank shall be tested to the pressure prescribed in § 179.301. Pressure shall be maintained...

  12. 49 CFR 179.300-16 - Tests of tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) [Reserved] (b) After all fittings have been installed, each tank shall be subjected to interior air pressure... methods. No tank shall have been subjected previously to internal pressure within 100 pounds of the test pressure. Each tank shall be tested to the pressure prescribed in § 179.301. Pressure shall be maintained...

  13. 49 CFR 179.300-16 - Tests of tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) [Reserved] (b) After all fittings have been installed, each tank shall be subjected to interior air pressure... methods. No tank shall have been subjected previously to internal pressure within 100 pounds of the test pressure. Each tank shall be tested to the pressure prescribed in § 179.301. Pressure shall be maintained...

  14. Increased anal basal pressure in chronic anal fissures may be caused by overreaction of the anal-external sphincter continence reflex.

    PubMed

    van Meegdenburg, Maxime M; Trzpis, Monika; Heineman, Erik; Broens, Paul M A

    2016-09-01

    Chronic anal fissure is a painful disorder caused by linear ulcers in the distal anal mucosa. Even though it counts as one of the most common benign anorectal disorders, its precise etiology and pathophysiology remains unclear. Current thinking is that anal fissures are caused by anal trauma and pain, which leads to internal anal sphincter hypertonia. Increased anal basal pressure leads to diminished anodermal blood flow and local ischemia, which delays healing and leads to chronic anal fissure. The current treatment of choice for chronic anal fissure is either lateral internal sphincterotomy or botulinum toxin injections. In contrast to current thinking, we hypothesize that the external, rather than the internal, anal sphincter is responsible for increased anal basal pressure in patients suffering from chronic anal fissure. We think that damage to the anal mucosa leads to hypersensitivity of the contact receptors of the anal-external sphincter continence reflex, resulting in overreaction of the reflex. Overreaction causes spasm of the external anal sphincter. This in turn leads to increased anal basal pressure, diminished anodermal blood flow, and ischemia. Ischemia, finally, prevents the anal fissure from healing. Our hypothesis is supported by two findings. The first concerned a chronic anal fissure patient with increased anal basal pressure (170mmHg) who had undergone lateral sphincterotomy. Directly after the operation, while the submucosal anesthetic was still active, basal anal pressure decreased to 80mmHg. Seven hours after the operation, when the anesthetic had completely worn off, basal anal pressure increased again to 125mmHg, even though the internal anal sphincter could no longer be responsible for the increase. Second, in contrast to previous studies, recent studies demonstrated that botulinum toxin influences external anal sphincter activity and, because it is a striated muscle relaxant, it seems reasonable to presume that it affects the striated external anal sphincter, rather than the smooth internal anal sphincter. If our hypothesis is proved correct, the treatment option of lateral internal sphincterotomy should be abandoned in patients suffering from chronic anal fissures, since it fails to eliminate the cause of high anal basal pressure. Additionally, lateral internal sphincterotomy may cause damage to the anal-external sphincter continence reflex, resulting in fecal incontinence. Instead, higher doses of botulinum toxin should be administered to those patients suffering from chronic anal fissure who appeared unresponsive to lower doses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Evaluation of health care services provided for older adults in primary health care centers and its internal environment. A step towards age-friendly health centers.

    PubMed

    Alhamdan, Adel A; Alshammari, Sulaiman A; Al-Amoud, Maysoon M; Hameed, Tariq A; Al-Muammar, May N; Bindawas, Saad M; Al-Orf, Saada M; Mohamed, Ashry G; Al-Ghamdi, Essam A; Calder, Philip C

    2015-09-01

    To evaluate the health care services provided for older adults by primary health care centers (PHCCs) in Riyadh, Kingdom of Saudi Arabia (KSA), and the ease of use of these centers by older adults. Between October 2013 and January 2014, we conducted a descriptive cross-sectional study of 15 randomly selected PHCCs in Riyadh City, KSA. The evaluation focused on basic indicators of clinical services offered and factors indicative of the ease of use of the centers by older adults. Evaluations were based upon the age-friendly PHCCs toolkit of the World Health Organization. Coverage of basic health assessments (such as blood pressure, diabetes, and blood cholesterol) was generally good. However, fewer than half of the PHCCs offered annual comprehensive screening for the common age-related conditions. There was no screening for cancer. Counseling on improving lifestyle was provided by most centers. However, there was no standard protocol for counseling. Coverage of common vaccinations was poor. The layout of most PHCCs and their signage were good, except for lack of Braille signage. There may be issues of access of older adults to PHCCs through lack of public transport, limited parking opportunities, the presence of steps, ramps, and internal stairs, and the lack of handrails. Clinical services and the internal environment of PHCCs can be improved. The data will be useful for health-policy makers to improve PHCCs to be more age-friendly.

  16. Evaluation of health care services provided for older adults in primary health care centers and its internal environment

    PubMed Central

    Alhamdan, Adel A.; Alshammari, Sulaiman A.; Al-Amoud, Maysoon M.; Hameed, Tariq A.; Al-Muammar, May N.; Bindawas, Saad M.; Al-Orf, Saada M.; Mohamed, Ashry G.; Al-Ghamdi, Essam A.; Calder, Philip C.

    2015-01-01

    Objectives: To evaluate the health care services provided for older adults by primary health care centers (PHCCs) in Riyadh, Kingdom of Saudi Arabia (KSA), and the ease of use of these centers by older adults. Methods: Between October 2013 and January 2014, we conducted a descriptive cross-sectional study of 15 randomly selected PHCCs in Riyadh City, KSA. The evaluation focused on basic indicators of clinical services offered and factors indicative of the ease of use of the centers by older adults. Evaluations were based upon the age-friendly PHCCs toolkit of the World Health Organization. Results: Coverage of basic health assessments (such as blood pressure, diabetes, and blood cholesterol) was generally good. However, fewer than half of the PHCCs offered annual comprehensive screening for the common age-related conditions. There was no screening for cancer. Counseling on improving lifestyle was provided by most centers. However, there was no standard protocol for counseling. Coverage of common vaccinations was poor. The layout of most PHCCs and their signage were good, except for lack of Braille signage. There may be issues of access of older adults to PHCCs through lack of public transport, limited parking opportunities, the presence of steps, ramps, and internal stairs, and the lack of handrails. Conclusions: Clinical services and the internal environment of PHCCs can be improved. The data will be useful for health-policy makers to improve PHCCs to be more age-friendly. PMID:26318467

  17. Diet and physical activity among migrant Bougainvilleans in Port Moresby, Papua New Guinea: association with anthropometric measures and blood pressure.

    PubMed

    Vengiau, Gwendalyn; Umezaki, Masahiro; Phuanukoonnon, Suparat; Siba, Peter; Watanabe, Chiho

    2012-01-01

    Obesity and hypertension are increasing in Papua New Guinea. This study investigated the association of dietary pattern and physical activity level with anthropometric measurements and blood pressure in migrant Bougainvilleans in the capital city of Port Moresby. Adults who had moved from Naasioi territory on Bougainville Island and resided in Port Moresby during the study period were studied (n = 70). The International Physical Activity Questionnaire was used to evaluate physical activity, and dietary pattern was assessed by per week consumption frequency of food items. The least square regression analysis revealed that interindividual variation in body mass index and waist circumference was explained by variations in physical activity but not by dietary pattern. Blood pressure was not associated with physical activity level or dietary pattern. The individual variation in anthropometric measurements in urban Papua New Guinea is mainly influenced by physical activity level. Copyright © 2012 Wiley Periodicals, Inc.

  18. Design study of an advanced gas generator. [which can be ignited during start-up period of turbine engines

    NASA Technical Reports Server (NTRS)

    Kim, S.; Trinh, H. P.

    1993-01-01

    A gas generator which can be ignited reliably during the initial start-up period and offers fairly uniform gas temperature at the exit was studied numerically. Various sizes and shapes of the mixing enhancement devices and their positions were examined to evaluate the uniformity of the exit gas temperature and the change of internal pressure drop incurred by introducing the mixing enhancement devices. By introducing a turbulence ring and a splash plate with an appropriate size and position, it was possible to obtain fairly uniform gas temperature distributions and a maximum gas temperature that is within the design limit temperature of 1600 R at the generator exit. However, with the geometry studied, the pressure drop across the generator was great, approximately 1150 psi, to satisfy the assigned design limit temperature. If the design limit temperature is increased to 1650 R, the pressure drop across the generator could be lowered by as much as 350 psi.

  19. Neural-Net Processed Characteristic Patterns for Measurement of Structural Integrity of Pressure Cycled Components

    NASA Technical Reports Server (NTRS)

    Decker, A. J.

    2001-01-01

    A neural-net inspection process has been combined with a bootstrap training procedure and electronic holography to detect changes or damage in a pressure-cycled International Space Station cold plate to be used for cooling instrumentation. The cold plate was excited to vibrate in a normal mode at low amplitude, and the neural net was trained by example to flag small changes in the mode shape. The NDE (nondestructive-evaluation) technique is straightforward but in its infancy; its applications are ad-hoc and uncalibrated. Nevertheless previous research has shown that the neural net can detect displacement changes to better than 1/100 the maximum displacement amplitude. Development efforts that support the NDE technique are mentioned briefly, followed by descriptions of electronic holography and neural-net processing. The bootstrap training procedure and its application to detection of damage in a pressure-cycled cold plate are discussed. Suggestions for calibrating and quantifying the NDE procedure are presented.

  20. One-dimensional model for the intracranial pulse morphological analysis during hyperventilation and CO2 inhalation tests

    NASA Astrophysics Data System (ADS)

    Ryu, Jaiyoung; Hu, Xiao; Shadden, Shawn C.

    2015-11-01

    The brain's CO2 reactivity mechanism is coupled with cerebral autoregulation and other unique features of cerebral hemodynamics. We developed a one-dimensional nonlinear model of blood flow in the cerebral arteries coupled to lumped parameter (LP) networks. The LP networks incorporate cerebral autoregulation, CO2 reactivity, intracranial pressure, cerebrospinal fluid, and cortical collateral blood flow models. The model was used to evaluate hemodynamic variables (arterial deformation, blood velocity and pressure) in the cerebral vasculature during hyperventilation and CO2 inhalation test. Tests were performed for various arterial blood pressure (ABP) representing normal and hypotensive conditions. The increase of the cerebral blood flow rates agreed well with the published measurements for various ABP measurements taken during clinical CO2 reactivity tests. The changes in distal vasculature affected the reflected pulse wave energy, which caused the waveform morphological changes at the middle cerebral, common and internal carotid arteries. The pulse morphological analysis demonstrated agreement with previous clinical measurements for cerebral vasoconstriction and vasodilation.

  1. Pressure control of a proton beam-irradiated water target through an internal flow channel-induced thermosyphon.

    PubMed

    Hong, Bong Hwan; Jung, In Su

    2017-07-01

    A water target was designed to enhance cooling efficiency using a thermosyphon, which is a system that uses natural convection to induce heat exchange. Two water targets were fabricated: a square target without any flow channel and a target with a flow channel design to induce a thermosyphon mechanism. These two targets had the same internal volume of 8 ml. First, visualization experiments were performed to observe the internal flow by natural convection. Subsequently, an experiment was conducted to compare the cooling performance of both water targets by measuring the temperature and pressure. A 30-MeV proton beam with a beam current of 20 μA was used to irradiate both targets. Consequently, the target with an internal flow channel had a lower mean temperature and a 50% pressure drop compared to the target without a flow channel during proton beam irradiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. [Evaluation of the quality of medical care in primary care patients with metabolic syndrome].

    PubMed

    Modrego Navarro, Angel; Ramírez Espinosa, Manuel; Fustero Fernández, Mariví; Tarraga López, Pedro Juan; Bastida Calvo, José Carlos; Torras Tohà, Núria

    2009-08-01

    As there is a high prevalence of metabolic syndrome (MS) in the overweight population, their cardiovascular risk is also high and the review system in Spain appears to be inadequate. The present study was carried out to evaluate the quality of the medical care of these patients. Epidemiological, cross-sectional and multicenter study. A total of 138 primary care general practitioners from all over Spain included outpatients of both sexes, > 18 years old, with body mass index > or = 25 and with biochemical data from the last 6 months for fasting glucose, triglycerides, HDL-c and blood pressure. Self-evaluation, retrospective, internal and with data processing. Principal determinations: Degree of compliance of 12 evaluation criteria and description of MS factors. A total of 2,280 patients were analysed. MS prevalence was 53.2%. Biochemical data were significantly higher in patients with MS and the most prevalent risk factors were: triglycerides > 150 (49.6%), systolic blood pressure > 140 (40.8%), fasting glucose > or = 126 (38.4%). Poor compliance of a few but relevant criteria was responsible for a high percentage of errors in the medical care quality. Introduction of improvement activities in patients with MS in primary care is essential in the management and prevention of cardiovascular complications.

  3. An innovative methodology for measurement of stress distribution of inflatable membrane structures

    NASA Astrophysics Data System (ADS)

    Zhao, Bing; Chen, Wujun; Hu, Jianhui; Chen, Jianwen; Qiu, Zhenyu; Zhou, Jinyu; Gao, Chengjun

    2016-02-01

    The inflatable membrane structure has been widely used in the fields of civil building, industrial building, airship, super pressure balloon and spacecraft. It is important to measure the stress distribution of the inflatable membrane structure because it influences the safety of the structural design. This paper presents an innovative methodology for the measurement and determination of the stress distribution of the inflatable membrane structure under different internal pressures, combining photogrammetry and the force-finding method. The shape of the inflatable membrane structure is maintained by the use of pressurized air, and the internal pressure is controlled and measured by means of an automatic pressure control system. The 3D coordinates of the marking points pasted on the membrane surface are acquired by three photographs captured from three cameras based on photogrammetry. After digitizing the markings on the photographs, the 3D curved surfaces are rebuilt. The continuous membrane surfaces are discretized into quadrilateral mesh and simulated by membrane links to calculate the stress distributions using the force-finding method. The internal pressure is simplified to the external node forces in the normal direction according to the contributory area of the node. Once the geometry x, the external force r and the topology C are obtained, the unknown force densities q in each link can be determined. Therefore, the stress distributions of the inflatable membrane structure can be calculated, combining the linear adjustment theory and the force density method based on the force equilibrium of inflated internal pressure and membrane internal force without considering the mechanical properties of the constitutive material. As the use of the inflatable membrane structure is attractive in the field of civil building, an ethylene-tetrafluoroethylene (ETFE) cushion is used with the measurement model to validate the proposed methodology. The comparisons between the obtained results and numerical simulation for the inflation process of the ETFE cushion are performed, and the strong agreements demonstrate that the proposed methodology is feasible and accurate.

  4. FOREWORD: The 4th CCM International Conference on Pressure Metrology from Ultra-High Vacuum to Very High Pressures (10-9 Pa to 109 Pa)

    NASA Astrophysics Data System (ADS)

    Legras, Jean-Claude; Jousten, Karl; Severn, Ian

    2005-12-01

    The fourth CCM (Consultative Committee for Mass and related quantities) International Conference on Pressure Metrology from Ultra-High Vacuum to Very High Pressures (10-9 Pa to 109 Pa) was held at the Institute of Physics in London from 19-21 April 2005. The event, which was organized by the Low, Medium and High Pressure working groups of the CCM, was attended by in excess of one hundred participants with representatives from five continents and every regional metrology organization. The purpose of this conference is to review all the work that is devoted to the highest quality of pressure measurement by primary standards as well as the dissemination of the pressure scale. A total of 52 papers were presented orally, and 26 as posters, in sessions that covered the following topics: Latest scientific advances in pressure and vacuum metrology Innovative transfer standards, advanced sensors and new instrument development Primary (top-level) measurement standards International and regional key comparisons New approaches to calibration It is interesting the note that since the third conference in 1999 the pressure range covered has increased by two orders of magnitude to 109 Pa, to take into account more exacting scientific and industrial demands for traceable vacuum measurement. A further feature of the conference was the increased range of instrumentation and techniques used in the realization and potential realization of pressure standards. Seton Bennett, Director of International Metrology at the National Physical Laboratory, opened the conference and Andrew Wallard, Director of the Bureau International des Poids et Mesures (BIPM), gave the keynote address which described the implementation of the mutual recognition arrangement and the resulting removal of metrological barriers to international trade. Many experts have contributed significant amounts of their time to organize the event and to review the submitted papers. Thanks are due to all of these people, particularly Gianfranco Molinar who offered much advice based on experience of organizing the previous conference. Special thanks must also be made to Mitsuru Tanaka, President of the CCM, and Andrew Wallard, Director of the BIPM, for their support of the event. The event was coordinated by Jasmina Bolfek-Radovani, of the Institute of Physics, without whose tireless efforts the event would not have been as successful. The production of this issue of Metrologia would not have been possible without the help and support of its editor, Jeffrey Williams. The National Measurement System Directorate of the Department of Trade and Industry supported the conference and it was sponsored by DH Instruments and BOC Edwards. Additional financial assistance was also received from Chell Instruments Ltd, DH-Budenberg, GE Infrastructure Sensing, Hi-Pro Pressure Products Ltd, Kurt J Lesker Company Ltd and Leybold Vacuum UK Ltd. Finally we would like to thank all of the conference participants who made the event both technically stimulating and enjoyable. By the time the next CCM Pressure conference is held in Berlin in 2011, pressure science and technology will undoubtedly have moved on still further and we may see the culmination of work to realize primary pressure standards by more fundamental methods.

  5. An investigation of noise produced by unsteady gas flow through silencer elements

    NASA Astrophysics Data System (ADS)

    Mawhinney, Graeme Hugh

    This thesis presents an investigation of the noise produced by unsteady gas flow through silencer elements. The central aim of the research project was to produce a tool for assistance in the design of the exhaust systems of diesel powered electrical generator sets, with the modelling techniques developed having a much wider application in reciprocating internal combustion engine exhaust systems. An automotive cylinder head was incorporated in a purpose built test rig to supply exhaust pulses, typical of those found in the exhaust system of four stroke diesel engines, to various experimental exhaust systems. Exhaust silencer elements evaluated included expansion, re- entrant, concentric tube resonator and absorptive elements. Measurements taken on the test rig included, unsteady superposition pressure in the exhaust ducting, cyclically averaged mass flow rate through the system and exhaust noise levels radiated into a semi-anechoic measurement chamber. The entire test rig was modelled using the 1D finite volume method developed previously developed at Queen's University Belfast. Various boundary conditions, developed over the years, were used to model the various silencer elements being evaluated. The 1D gas dynamic simulation thus estimated the mass flux history at the open end of the exhaust system. The mass flux history was then broken into its harmonic components and an acoustic radiation model was developed to model the sound pressure level produced by an acoustic monopole over a reflecting plane. The accuracy of the simulation technique was evaluated by correlation of measured and simulated superposition pressure and noise data. In general correlation of superposition pressure was excellent for all of the silencer elements tested. Predicted sound pressure level radiated from the open end of the exhaust tailpipe was seen to be accurate in the 100 Hz to 1 kHz frequency range for all of the silencer elements tested.

  6. New Horizons Tanzania, Ltd.--A Case of International HRD in Two Parts (Part Two)

    ERIC Educational Resources Information Center

    Williams, Sandra L.; Hurley, Mark N.

    2017-01-01

    In this second segment of HRD in a developing country situation, accelerated pressure for organizational growth is placed upon leaders by the international board of directors. This growth pressure is accompanied by new technology which can assist in growth accomplishment, but which demands further training and orientation of cross-cultural…

  7. Deformation and stress response of composite laminated shells under internal pressure

    NASA Technical Reports Server (NTRS)

    Yuan, F. G.

    1991-01-01

    This paper presents a theoretical study of the response of filament wound composite shells under internal pressure. Each layer of the material is generally cylindrically anisotropic. By using cylindrically anisotropic elasticity field equations and Lekhnitskii's stress functions, a system of sixth-order ordinary differential equations is obtained. The general expressions for the stresses and displacements in the laminated composite shells under internal pressure are discussed. Two composite systems, graphite/epoxy and glass/epoxy, are selected to demonstrate the influence of degree of material anisotropy and fiber orientations on the axial and induced twisting deformation. Stress distributions of (45/-45)s symmetric angle-ply fiber-reinforced laminated shells are shown to illustrate the effect of radius-to-thickness ratio.

  8. ISS Interface Mechanisms and their Heritage

    NASA Technical Reports Server (NTRS)

    Cook, John G.; Aksamentov, Valery; Hoffman, Thomas; Bruner, Wes

    2011-01-01

    The International Space Station, by nurturing technological development of a variety of pressurized and unpressurized interface mechanisms fosters "competition at the technology level". Such redundancy and diversity allows for the development and testing of mechanisms that might be used for future exploration efforts. The International Space Station, as a test-bed for exploration, has 4 types of pressurized interfaces between elements and 6 unpressurized attachment mechanisms. Lessons learned from the design, test and operations of these mechanisms will help inform the design for a new international standard pressurized docking mechanism for the NASA Docking System. This paper will examine the attachment mechanisms on the ISS and their attributes. It will also look ahead at the new NASA docking system and trace its lineage to heritage mechanisms.

  9. Internal motion and its pressure dependence in FeSiF6+6/H2O/.

    NASA Technical Reports Server (NTRS)

    Vaughan, R. W.; Nicolaides, G. L.; Elleman, D. D.

    1972-01-01

    Both wideline and pulsed NMR techniques were used to examine the internal motion in FeSiF6+6(H2O). Corrections of second moments for bulk paramagnetic effects were essential. At room temperature and pressure, the fluorine-fluorine contribution to the 19F second moment is 0.38 (plus or minus 0.06) G2, and indicates rapid orientation of the SiF6(--) group. Analysis of the second moment within the transition region allows calculation of an activation volume which is 2.4 (plus or minus 0.4) % of the molar volume. The application of pressure slows the internal motion such that the rigid lattice values of the 19F second moment are obtained above 50 kbar.

  10. Can single use negative pressure wound therapy be an alternative method to manage keloid scarring? A preliminary report of a clinical and ultrasound/colour-power-doppler study.

    PubMed

    Fraccalvieri, Marco; Sarno, Antonino; Gasperini, Stefano; Zingarelli, Enrico; Fava, Raffaella; Salomone, Marco; Bruschi, Stefano

    2013-06-01

    Keloid scarring represents a pathological healing where primary healing phenomenon is deviated from normal. Pico is a single use negative pressure wound therapy system originally introduced to manage open or just closed wounds. Pico dressing is made of silicone, and distributes an 80 mmHg negative pressure across wound bed. Combination of silicon layer and continuous compression could be a valid method to manage keloid scarring. Since November 2011, three patients were enrolled and evaluated before negative pressure treatment, at end of treatment (1 month) and 2 months later, through Vancouver Scar Scale (VSS), Visual Analog Scale (VAS) and a scoring system for itching. Ultrasound (US) and colour-power-doppler (CPD) examination was performed to evaluate thickness and vascularisation of the scar. One patient was discharged from study after 1 week. In last two patients, VSS, VAS and itching significantly improved after 1 month therapy and the results were stable after 2 months without any therapy. At end of therapy, the 'appearance of palisade vessels' disappeared in both cases at CPD exam; US showed a thickness reduction (average 43·8%). We propose a well-tolerated, non invasive treatment to manage keloid scarring. Prospective studies are necessary to investigate whether these preliminary observations are confirmed. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.

  11. 75 FR 27706 - Pressure Sensitive Plastic Tape From Italy: Final Results of Antidumping Duty Changed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-18

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-059] Pressure Sensitive Plastic...-interest to Evotape S.p.A for purposes of determining antidumping liability. See Pressure Sensitive Plastic...

  12. Medication monitoring attitudes and perceived determinants to offering medication adherence advice to older hypertensive adults: a factorial survey of community pharmacy interns.

    PubMed

    Dillon, Paul; Smith, Susan M; Gallagher, Paul; Cousins, Gráinne

    2018-06-13

    Community pharmacy is an ideal setting to monitor medication adherence, however, barriers to pharmacist-led interventions exist. Preparing future pharmacists for enhanced roles may overcome such barriers. Our objective was to identify medication monitoring attitudes and contextual factors that influence adherence monitoring by pharmacy interns to inform educational activities on medication adherence. An online factorial survey of all pharmacy interns (N = 123) in the Republic of Ireland, completing advanced community pharmacy experiential learning in May 2016 was undertaken to evaluate attitudes to medication monitoring and to identify respondent characteristics and contextual factors which influence adherence monitoring of older hypertensive adults during repeat dispensing. The medication monitoring attitude measure (MMAM) was used to evaluate interns' attitudes, and factorial vignette analysis was performed to identify factors influencing behavioural intention to offer adherence advice. There were 121 completed online surveys. Half of interns reported they felt uncomfortable and confrontational discussing adherence with patients. In factorial vignette analysis, higher medication monitoring attitudes resulted in higher likelihood to offer adherence advice; experiential-learning characteristics such as pharmacy ownership-type (nonchain store) and contextual factors including patients being treated for longer and time-pressures had a significant negative influence on pharmacy interns' likelihood to offer adherence advice. Medication monitoring attitudes and contextual factors influenced responses to offer adherence advice in hypothetical scenarios. Ensuring pharmacy students are educated on patterns of adherence and appropriate skills to address nonadherence, and engage in structured programmes to facilitate patient interactions during experiential learning, may improve medication monitoring attitudes and adherence monitoring. © 2018 Royal Pharmaceutical Society.

  13. Launcher Dynamic Data Acquisition

    DTIC Science & Technology

    2012-07-31

    K PR Pressure PR Pressure PR Accelerometer PR Accelerometer PR Accelerometer PR Pressure PR Pressure IEPE Microphone IEPE ...transducers, displacement potentiometers, or Integrated Electronics Piezoelectric ( IEPE ) microphones and accelerometers. The characteristics of these...Engineering Units HCl hydrogen chloride HVAC heating ventilation and cooling Hz hertz IEC International Electrotechnical Commission IEPE

  14. 76 FR 33239 - High Pressure Steel Cylinders From the People's Republic of China; Initiation of Countervailing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-978] High Pressure Steel... countervailing duty (``CVD'') petition concerning imports of high pressure steel cylinders (``steel cylinders... of Antidumping Duties and Countervailing Duties on High Pressure Steel Cylinders from the People's...

  15. Blood pressure variability of two ambulatory blood pressure monitors.

    PubMed

    Kallem, Radhakrishna R; Meyers, Kevin E C; Cucchiara, Andrew J; Sawinski, Deirdre L; Townsend, Raymond R

    2014-04-01

    There are no data on the evaluation of blood pressure (BP) variability comparing two ambulatory blood pressure monitoring monitors worn at the same time. Hence, this study was carried out to compare variability of BP in healthy untreated adults using two ambulatory BP monitors worn at the same time over an 8-h period. An Accutorr device was used to measure office BP in the dominant and nondominant arms of 24 participants.Simultaneous 8-h BP and heart rate data were measured in 24 untreated adult volunteers by Mobil-O-Graph (worn for an additional 16 h after removing the Spacelabs monitor) and Spacelabs with both random (N=12) and nonrandom (N=12) assignment of each device to the dominant arm. Average real variability (ARV), SD, coefficient of variation, and variation independent of mean were calculated for systolic blood pressure, diastolic blood pressure, mean arterial pressure, and pulse pressure (PP). Whether the Mobil-O-Graph was applied to the dominant or the nondominant arm, the ARV of mean systolic (P=0.003 nonrandomized; P=0.010 randomized) and PP (P=0.009 nonrandomized; P=0.005 randomized) remained significantly higher than the Spacelabs device, whereas the ARV of the mean arterial pressure was not significantly different. The average BP readings and ARVs for systolic blood pressure and PP obtained by the Mobil-O-Graph were considerably higher for the daytime than the night-time. Given the emerging interest in the effect of BP variability on health outcomes, the accuracy of its measurement is important. Our study raises concerns about the accuracy of pooling international ambulatory blood pressure monitoring variability data using different devices.

  16. Management of high blood pressure in Blacks: an update of the International Society on Hypertension in Blacks consensus statement.

    PubMed

    Flack, John M; Sica, Domenic A; Bakris, George; Brown, Angela L; Ferdinand, Keith C; Grimm, Richard H; Hall, W Dallas; Jones, Wendell E; Kountz, David S; Lea, Janice P; Nasser, Samar; Nesbitt, Shawna D; Saunders, Elijah; Scisney-Matlock, Margaret; Jamerson, Kenneth A

    2010-11-01

    Since the first International Society on Hypertension in Blacks consensus statement on the "Management of High Blood Pressure in African American" in 2003, data from additional clinical trials have become available. We reviewed hypertension and cardiovascular disease prevention and treatment guidelines, pharmacological hypertension clinical end point trials, and blood pressure-lowering trials in blacks. Selected trials without significant black representation were considered. In this update, blacks with hypertension are divided into 2 risk strata, primary prevention, where elevated blood pressure without target organ damage, preclinical cardiovascular disease, or overt cardiovascular disease for whom blood pressure consistently <135/85 mm Hg is recommended, and secondary prevention, where elevated blood pressure with target organ damage, preclinical cardiovascular disease, and/or a history of cardiovascular disease, for whom blood pressure consistently <130/80 mm Hg is recommended. If blood pressure is ≤10 mm Hg above target levels, monotherapy with a diuretic or calcium channel blocker is preferred. When blood pressure is >15/10 mm Hg above target, 2-drug therapy is recommended, with either a calcium channel blocker plus a renin-angiotensin system blocker or, alternatively, in edematous and/or volume-overload states, with a thiazide diuretic plus a renin-angiotensin system blocker. Effective multidrug therapeutic combinations through 4 drugs are described. Comprehensive lifestyle modifications should be initiated in blacks when blood pressure is ≥115/75 mm Hg. The updated International Society on Hypertension in Blacks consensus statement on hypertension management in blacks lowers the minimum target blood pressure level for the lowest-risk blacks, emphasizes effective multidrug regimens, and de-emphasizes monotherapy.

  17. Investigating the mechanism underlying urinary continence recovery after radical prostatectomy: effectiveness of a longer urethral stump to prevent urinary incontinence.

    PubMed

    Kadono, Yoshifumi; Nohara, Takahiro; Kawaguchi, Shohei; Naito, Renato; Urata, Satoko; Nakashima, Kazufumi; Iijima, Masashi; Shigehara, Kazuyoshi; Izumi, Kouji; Gabata, Toshifumi; Mizokami, Atsushi

    2018-02-28

    To assess the chronological changes in urinary incontinence and urethral function before and after radical prostatectomy (RP), and to compare the findings of pelvic magnetic resonance imaging (MRI) before and after RP to evaluate the anatomical changes. In total, 185 patients were evaluated with regard to the position of the distal end of the membranous urethra (DMU) on a mid-sagittal MRI slice and urethral sphincter function using the urethral pressure profilometry. The patients also underwent an abdominal leak point pressure test before RP and at 10 days and 12 months after RP. The results were then compared with the chronological changes in urinary incontinence. The MRI results showed that the DMU shifted proximally to an average distance of 4 mm at 10 days after RP and returned to the preoperative position at 12 months after RP. Urethral sphincter function also worsened 10 days after RP, with recovery after 12 months. The residual length of the urethral stump and urinary incontinence were significantly associated with the migration length of the DMU at 10 days after RP. The residual length of the urethral stump was a significant predictor of urinary incontinence after RP. This is the first study to elucidate that the slight vertical repositioning of the membranous urethra after RP causes chronological changes in urinary incontinence. A long urethral residual stump reduces urinary incontinence after RP. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  18. Probabilistic Evaluation of Advanced Ceramic Matrix Composite Structures

    NASA Technical Reports Server (NTRS)

    Abumeri, Galib H.; Chamis, Christos C.

    2003-01-01

    The objective of this report is to summarize the deterministic and probabilistic structural evaluation results of two structures made with advanced ceramic composites (CMC): internally pressurized tube and uniformly loaded flange. The deterministic structural evaluation includes stress, displacement, and buckling analyses. It is carried out using the finite element code MHOST, developed for the 3-D inelastic analysis of structures that are made with advanced materials. The probabilistic evaluation is performed using the integrated probabilistic assessment of composite structures computer code IPACS. The affects of uncertainties in primitive variables related to the material, fabrication process, and loadings on the material property and structural response behavior are quantified. The primitive variables considered are: thermo-mechanical properties of fiber and matrix, fiber and void volume ratios, use temperature, and pressure. The probabilistic structural analysis and probabilistic strength results are used by IPACS to perform reliability and risk evaluation of the two structures. The results will show that the sensitivity information obtained for the two composite structures from the computational simulation can be used to alter the design process to meet desired service requirements. In addition to detailed probabilistic analysis of the two structures, the following were performed specifically on the CMC tube: (1) predicted the failure load and the buckling load, (2) performed coupled non-deterministic multi-disciplinary structural analysis, and (3) demonstrated that probabilistic sensitivities can be used to select a reduced set of design variables for optimization.

  19. 49 CFR 179.500-14 - Test of tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500-14 Test of tanks. (a... internal pressure greater than 90 percent of the marked test pressure. Each tank shall be tested to a pressure at least equal to the marked test pressure of the tank. Pressure shall be maintained for 30...

  20. Evaluation of marine subareas of Europe using life history parameters and trophic levels of selected fish populations.

    PubMed

    Jayasinghe, R P Prabath K; Amarasinghe, Upali S; Newton, Alice

    2015-12-01

    European marine waters include four regional seas that provide valuable ecosystem services to humans, including fish and other seafood. However, these marine environments are threatened by pressures from multiple anthropogenic activities and climate change. The European Marine Strategy Framework Directive (MSFD) was adopted in 2008 to achieve good environmental status (GEnS) in European Seas by year 2020, using an Ecosystem Approach. GEnS is to be assessed using 11 descriptors and up to 56 indicators. In the present analysis two descriptors namely "commercially exploited fish and shellfish populations" and "food webs" were used to evaluate the status of subareas of FAO 27 area. Data on life history parameters, trophic levels and fisheries related data of cod, haddock, saithe, herring, plaice, whiting, hake and sprat were obtained from the FishBase online database and advisory reports of International Council for the Exploration of the Sea (ICES). Subareas inhabited by r and K strategists were identified using interrelationships of life history parameters of commercially important fish stocks. Mean trophic level (MTL) of fish community each subarea was calculated and subareas with species of high and low trophic level were identified. The Fish in Balance (FiB) index was computed for each subarea and recent trends of FiB indices were analysed. The overall environmental status of each subarea was evaluated considering life history trends, MTL and FiB Index. The analysis showed that subareas I, II, V, VIII and IX were assessed as "good" whereas subareas III, IV, VI and VII were assessed as "poor". The subareas assessed as "good" were subject to lower environmental pressures, (less fishing pressure, less eutrophication and more water circulation), while the areas with "poor" environment experienced excessive fishing pressure, eutrophication and disturbed seabed. The evaluation was based on two qualitative descriptors ("commercially exploited fish and shellfish populations" and "food webs") is therefore more robust. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Growth mechanism and internal structure of vertically aligned single-walled carbon nanotubes.

    PubMed

    Einarsson, Erik; Kadowaki, Masayuki; Ogura, Kazuaki; Okawa, Jun; Xiang, Rong; Zhang, Zhengyi; Yamamoto, Takahisa; Ikuhara, Yuichi; Maruyama, Shigeo

    2008-11-01

    An in situ optical absorbance technique was used to monitor the growth of vertically aligned single-walled carbon nanotubes (VA-SWNTs) at various temperatures and pressures. The effects of the growth temperature and ethanol pressure on the initial growth rate and catalyst lifetime were investigated. It was found that the ideal pressure for VA-SWNT synthesis changes with the growth temperature, shifting toward higher pressure as the growth temperature increases. It was also found that the growth reaction is first-order below this ideal pressure. Additionally, the internal structure of the VA-SWNT film was observed at different depths into the film by transmission electron microscopy. The absence of large bundles was confirmed, and little change in the structure was observed to a depth of approximately 1 microm.

  2. Exhaust gas recirculation system for an internal combustion engine

    DOEpatents

    Wu, Ko-Jen

    2013-05-21

    An exhaust gas recirculation system for an internal combustion engine comprises an exhaust driven turbocharger having a low pressure turbine outlet in fluid communication with an exhaust gas conduit. The turbocharger also includes a low pressure compressor intake and a high pressure compressor outlet in communication with an intake air conduit. An exhaust gas recirculation conduit fluidly communicates with the exhaust gas conduit to divert a portion of exhaust gas to a low pressure exhaust gas recirculation branch extending between the exhaust gas recirculation conduit and an engine intake system for delivery of exhaust gas thereto. A high pressure exhaust gas recirculation branch extends between the exhaust gas recirculation conduit and the compressor intake and delivers exhaust gas to the compressor for mixing with a compressed intake charge for delivery to the intake system.

  3. Low internal pressure in femtoliter water capillary bridges reduces evaporation rates

    PubMed Central

    Cho, Kun; Hwang, In Gyu; Kim, Yeseul; Lim, Su Jin; Lim, Jun; Kim, Joon Heon; Gim, Bopil; Weon, Byung Mook

    2016-01-01

    Capillary bridges are usually formed by a small liquid volume in a confined space between two solid surfaces. They can have a lower internal pressure than the surrounding pressure for volumes of the order of femtoliters. Femtoliter capillary bridges with relatively rapid evaporation rates are difficult to explore experimentally. To understand in detail the evaporation of femtoliter capillary bridges, we present a feasible experimental method to directly visualize how water bridges evaporate between a microsphere and a flat substrate in still air using transmission X-ray microscopy. Precise measurements of evaporation rates for water bridges show that lower water pressure than surrounding pressure can significantly decrease evaporation through the suppression of vapor diffusion. This finding provides insight into the evaporation of ultrasmall capillary bridges. PMID:26928329

  4. Weather types in the South Shetlands (Antarctica) using a circulation type approach

    NASA Astrophysics Data System (ADS)

    Mora, Carla; João Rocha, Maria; Dutra, Emanuel; Trigo, Isabel; Vieira, Gonçalo; Fragoso, Marcelo; Ramos, Miguel

    2010-05-01

    Weather types in the South Shetlands (Antarctica) were defined using an automated method based on the Lamb Weather Type classification scheme (Jones et al. 1993). This is an objective classification originally developed for the British Isles (Jones et al., 1993) and also applied to southeast (Goodess and Palutikof 1998) and northwest Spain (Lorenzo et al, 2009), Portugal (Trigo and DaCamara 2000) and Greece (Maheras et al. 2004) with good results. Daily atmospheric circulation in the South Shetlands region from 1989 to 2009 was classified using a 16-node grid of sea level pressure data from the ERA Interim. The classification is obtained through the comparison of the magnitudes of the directional and rotational components of the geostrophic flow. Basic circulation types were combined into 10 groups of weather types: four directional types (NW, N, S and SW), three anticyclonic types (A, ASW and ANW), and three cyclonic types (C, CSW and CNW). Westerly flow and cyclonic circulation are the most frequent events throughout the year. The sea level pressure field for each weather type is presented and the synoptic characteristics are described. The analysis is based on ERA-Interim fields, including mean sea level pressure, precipitation, cloud cover, humidity and air temperature. Snow thickess modelled using HTESSEL is also considered. Analysis of variance (anova) and multivariate analysis (principal component analysis) are applied to evaluate the characteristics of each weather type. This circulation-type approach showed good results in the past for the downscaling of precipitation in other regions, and we are interested in evaluating the possibilities that the classification offers for downscaling precipitation, but also for snow and air temperature. For this we will be using observational data at test sites in Livingston and Deception islands. We are also motivated by the possibility of using the circulation-type approach as a predictor in statistical downscaling. References: Goodess CM, Palutikof JP.1998. Development of daily rainfall scenarios for southeast Spain using a Circulation-type approach to downscaling. International Journal of Climatology. 10: 1051-1083. JonesPD, Hulme M, Briffa KR. 1993. A comparison of Lamb circulation types with an objective classification scheme. International Journal of Climatology, 13:655-663. Lorenzo M N, Iglesias I , Taboada JJ , Gómez-Gesteira M. 2009. Relationship between monthly rainfall in northwest Iberian Peninsula and North Atlantic sea surface temperature. International Journal of Climatology. Maheras P, Tolika K, Anagnostopoulou C, Vafiadis M, Patrikas I, Flocas H. 2004. On the relationship between circulation types and changes in rainfall variability in Grece. International Journal of Climatology 24: 1695-1712. Trigo RM, DaCamara C. 2000. Circulation weather types and their influence on the precipitation regime in Portugal. International Journal of Climatology. 20: 1559-1581.

  5. Study on prestressed concrete reactor vessel structures. II-5: Crack analysis by three dimensional finite elements method of 1/20 multicavity type PCRV subjected to internal pressure

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A three-dimensional finite elements analysis is reported of the nonlinear behavior of PCRV subjected to internal pressure by comparing calculated results with test results. As the first stage, an analysis considering the nonlinearity of cracking in concrete was attempted. As a result, it is found possible to make an analysis up to three times the design pressure (50 kg/sqcm), and calculated results agree well with test results.

  6. International Space Station Environmental Control and Life Support System Acceptance Testing for the Pressurized Mating Adapters

    NASA Technical Reports Server (NTRS)

    Williams, David E.

    2008-01-01

    The International Space Station (ISS) Pressurized Mating Adapters (PMAs) Environmental Control and Life Support (ECLS) System is comprised of three subsystems: Atmosphere Control and Supply (ACS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). PMAs 1 and 2 flew to ISS on Flight 2A and Pressurized Mating Adapter (PMA) 3 flew to ISS on Flight 3A. This paper provides a summary of the PMAs ECLS design and a detailed discussion of the ISS ECLS Acceptance Testing methodologies utilized for the PMAs.

  7. Internal voltage control of hydrogen-oxygen fuel cells: Feasibility study

    NASA Technical Reports Server (NTRS)

    Prokopius, P. R.

    1975-01-01

    An experimental study was conducted to assess the feasibility of internal voltage regulation of fuel cell systems. Two methods were tested. In one, reactant partial pressure was used as the voltage control parameter and in the other reactant total pressure was used for control. Both techniques were breadboarded and tested on a single alkaline-electrolyte fuel cell. Both methods were found to be possible forms of regulation, however, of the two the total pressure technique would be more efficient, simpler to apply and would provide better transient characteristics.

  8. 49 CFR 173.27 - General requirements for transportation by aircraft.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... packaging requirements of this subchapter. (ii) Packagings which are subject to the hydrostatic pressure...-carrying aircraft. (c) Pressure requirements. (1) Packagings must be designed and constructed to prevent... without leakage the greater of— (i) An internal pressure which produces a gauge pressure of not less than...

  9. 77 FR 37384 - High Pressure Steel Cylinders From the People's Republic of China: Countervailing Duty Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-978] High Pressure Steel...''), the Department is issuing a countervailing duty order on high pressure steel cylinders (``steel... investigation of steel cylinders from the PRC. See High Pressure Steel Cylinders From the People's Republic of...

  10. 76 FR 33213 - High Pressure Steel Cylinders from the People's Republic of China: Initiation of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-977)] High Pressure Steel... (``Department'') received a petition concerning imports of high pressure steel cylinders (``steel cylinders...\\ (``Petitioner''). See Petitions for the Imposition of Antidumping and Countervailing Duties: High Pressure Steel...

  11. 76 FR 59658 - High Pressure Steel Cylinders From the People's Republic of China: Postponement of Preliminary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-27

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-977] High Pressure Steel... (``Department'') initiated an antidumping duty investigation on high pressure steel cylinders from the People's... for this investigation is currently due no later than October 18, 2011. \\1\\ See High Pressure Steel...

  12. 77 FR 26738 - High Pressure Steel Cylinders From the People's Republic of China: Final Affirmative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-978] High Pressure Steel... producers and exporters of high pressure steel cylinders (steel cylinders) from the People's Republic of... The following events have occurred since the Preliminary Determination.\\1\\ \\1\\ See High Pressure Steel...

  13. Measurement of anal pressure and motility.

    PubMed Central

    Hancock, B D

    1976-01-01

    A fine open perfused system and a closed balloon system for the measurement of anal pressure and motility have been compared. Measurements were made in 40 normal subjects and 84 patients with haemorrhoids. The rate of perfusion had a marked effect on the recorded pressure and motility details. The motility pattern was seen most clearly with the balloon probe and the pressure recorded was reproducible and easy to measure, making this a convenient method for recording activity of the internal anal sphincter. Anal motility in normal subjects was characterised by slow pressure waves (10-20/min). The frequency was fastest in the distal anal canal and this frequency gradient may represent a normal mechanism to keep the anal canal empty. Ultra slow pressure waves (0-6-1-9/min) were seen in 42% of patients with haemorrhoids and 5% of normal subjects and arose from a synchronous contraction of the whole internal sphincter. Images Fig. 1 PMID:976803

  14. Analytical and experimental study of axisymmetric truncated plug nozzle flow fields

    NASA Technical Reports Server (NTRS)

    Muller, T. J.; Sule, W. P.; Fanning, A. E.; Giel, T. V.; Galanga, F. L.

    1972-01-01

    Experimental and analytical investigation of the flow field and base pressure of internal-external-expansion truncated plug nozzles are discussed. Experimental results for two axisymmetric, conical plug-cylindrical shroud, truncated plug nozzles are presented for both open and closed wake operations. These results include extensive optical and pressure data covering nozzle flow field and base pressure characteristics, diffuser effects, lip shock strength, Mach disc behaviour, and the recompression and reverse flow regions. Transonic experiments for a special planar transonic section are presented. An extension of the analytical method of Hall and Mueller to include the internal shock wave from the shroud exit is presented for closed wake operation. Results of this analysis include effects on the flow field and base pressure of ambient pressure ratio, nozzle geometry, and the ratio of specific heats. Static thrust is presented as a function of ambient pressure ratio and nozzle geometry. A new transonic solution method is also presented.

  15. TexiCare: an innovative embedded device for pressure ulcer prevention. Preliminary results with a paraplegic volunteer.

    PubMed

    Chenu, Olivier; Vuillerme, Nicolas; Bucki, Marek; Diot, Bruno; Cannard, Francis; Payan, Yohan

    2013-08-01

    This paper introduces the recently developed TexiCare device that aims at preventing pressure ulcers for people with spinal cord injury. This embedded device is aimed to be mounted on the user wheelchair. Its sensor is 100% textile and allows the measurement of pressures at the interface between the cushion and the buttocks. It is comfortable, washable and low cost. It is connected to a cigarette-box sized unit that (i) measures the pressures in real time, (ii) estimates the risk for internal over-strains, and (iii) alerts the wheelchair user whenever necessary. The alert method has been defined as a result of a utility/usability/acceptability study conducted with representative end users. It is based on a tactile-visual feedback (via a watch or a smartphone for example): the tactile modality is used to discreetly alarm the person while the visual modality conveys an informative message. In order to evaluate the usability of the TexiCare device, a paraplegic volunteer equipped his wheelchair at home during a six months period. Interestingly, the first results revealed bad habits such as an inadequate posture when watching TV, rare relief maneuvers, and the occurrence of abnormal high pressures. Copyright © 2013 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  16. Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Xie, Peigen; Wang, Yanling; Xu, Xiaoying; Huang, Fei; Pan, Jingru

    2015-04-01

    The objective of this study was to determine the accuracy of the Pangao PG-800A11 wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the protocol of the British Hypertension Society (BHS). The device evaluations were performed in 85 participants, 33 of whom were included according to the ESH-IP revision 2010 and 52 of whom were included on the basis of the requirements of the BHS protocol. The validation procedure and data analysis followed the protocols precisely. The device achieved an A/A grading for the BHS protocol and passed all phases of the ESH-IP revision 2010 protocol. The mean difference ±SD for the ESH and BHS protocols, respectively, was -0.6±4.5 and -0.8±6.2 mmHg for systolic pressure and 1.2±4.6 and -0.5±5.1 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low, medium, and high-pressure ranges. The Pangao PG-800A11 wrist blood pressure monitor passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol in an adult population.

  17. Optimization of an Optical Test Bench for Tire Properties Measurement and Tread Defects Characterization

    PubMed Central

    Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Postigo Pozo, Sergio

    2017-01-01

    Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR) of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures. PMID:28353674

  18. Optimization of an Optical Test Bench for Tire Properties Measurement and Tread Defects Characterization.

    PubMed

    Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Postigo Pozo, Sergio

    2017-03-29

    Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR) of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures.

  19. A canine model of tracheal stenosis induced by cuffed endotracheal intubation

    PubMed Central

    Su, Zhuquan; Li, Shiyue; Zhou, Ziqing; Chen, Xiaobo; Gu, Yingying; Chen, Yu; Zhong, Changhao; Zhong, Minglu; Zhong, Nanshan

    2017-01-01

    Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuff pressures of 100 to 200 mmHg for 24 hr. The status of tracheal wall was evaluated by bronchoscopic and histological examinations. The model was successfully established by cuffed endotracheal intubation using an 8.0 mm tube and an intra-cuff pressure of 200 mmHg for 24 hr. When the intra-cuff pressures were kept constant, a larger sized tube would induce a larger tracheal wall pressure and more severe injury to the tracheal wall. The degree of tracheal stenosis ranged from 78% to 91% at 2 weeks postextubation. Histological examination demonstrated submucosal infiltration of inflammatory cells, hyperplasia of granulation tissue and collapse of tracheal cartilage. In summary, a novel animal model of tracheal stenosis was established by cuffed endotracheal intubation, whose histopathological feathers are similar to those of clinical cases of postintubation tracheal stenosis. Excessive cuff pressure and over-sized tube are the risk factors for postintubation tracheal stenosis. PMID:28349955

  20. Fine-touch pressure thresholds in the adult penis.

    PubMed

    Sorrells, Morris L; Snyder, James L; Reiss, Mark D; Eden, Christopher; Milos, Marilyn F; Wilcox, Norma; Van Howe, Robert S

    2007-04-01

    To map the fine-touch pressure thresholds of the adult penis in circumcised and uncircumcised men, and to compare the two populations. Adult male volunteers with no history of penile pathology or diabetes were evaluated with a Semmes-Weinstein monofilament touch-test to map the fine-touch pressure thresholds of the penis. Circumcised and uncircumcised men were compared using mixed models for repeated data, controlling for age, type of underwear worn, time since last ejaculation, ethnicity, country of birth, and level of education. The glans of the uncircumcised men had significantly lower mean (sem) pressure thresholds than that of the circumcised men, at 0.161 (0.078) g (P = 0.040) when controlled for age, location of measurement, type of underwear worn, and ethnicity. There were significant differences in pressure thresholds by location on the penis (P < 0.001). The most sensitive location on the circumcised penis was the circumcision scar on the ventral surface. Five locations on the uncircumcised penis that are routinely removed at circumcision had lower pressure thresholds than the ventral scar of the circumcised penis. The glans of the circumcised penis is less sensitive to fine touch than the glans of the uncircumcised penis. The transitional region from the external to the internal prepuce is the most sensitive region of the uncircumcised penis and more sensitive than the most sensitive region of the circumcised penis. Circumcision ablates the most sensitive parts of the penis.

  1. Static internal performance of single-expansion-ramp nozzles with various combinations of internal geometric parameters

    NASA Technical Reports Server (NTRS)

    Re, R. J.; Leavitt, L. D.

    1984-01-01

    The effects of five geometric design parameters on the internal performance of single-expansion-ramp nozzles were investigated at nozzle pressure ratios up to 10 in the static-test facility of the Langley 16-Foot Transonic Tunnel. The geometric variables on the expansion-ramp surface of the upper flap consisted of ramp chordal angle, ramp length, and initial ramp angle. On the lower flap, the geometric variables consisted of flap angle and flap length. Both internal performance and static-pressure distributions on the centerlines of the upper and lower flaps were obtained for all 43 nozzle configurations tested.

  2. DEVICE FOR CHARGING OR DISCHARGING

    DOEpatents

    Untemeyer, S.; Hutter, E.

    1959-01-13

    A loading and unloading device is presented for loading objects into and unloading them from an apparatus in which fluid under pressure is employed, such as a heterogeneous rcactor wherein the fuel elements are in the form of slugs. This device is comprised essentially of a cylindrical member disposed coaxially with and as an accessible extension of an internal tube member of the apparatus in which the objects, or fuel elements, are normally disposed in use. The outermost end of the cylindrical extension is closed by a removable seal plug. The lower end of the cylindrical extension is separated from the intennal tube by a disk valve which is operated externally. A source of pressure fluid and a drain line are provided in communication with the interior of the cylindrical extension. To load an object into the internal tube, the disk valve is closed, the seal plug is renmoved, an object is placed in the cylindrical extension, and the seal plug is replaced. The disk valve is then opened and ihe pressure of the fluid within the cylindrical extension is increased until it is greater than the pressure within the internal tube and forces the object out of the cylindrical extension into the internal tube. To remove an object from the tube the disk valve is opened and the intenior of thc cylindnical extension is connected to the drain line whereby the operating pressure within the intennal tube forces the object out of the internal tube and up into the cylindrical extension. The disk valve is then closed and the seal plug is removed to permit removal of the object.

  3. Computations of Internal and External Axisymmetric Nozzle Aerodynamics at Transonic Speeds

    NASA Technical Reports Server (NTRS)

    Dalbello, Teryn; Georgiadis, Nicholas; Yoder, Dennis; Keith, Theo

    2003-01-01

    Computational Fluid Dynamics (CFD) analyses of axisymmetric circular-arc boattail nozzles have been completed in support of NASA's Next Generation Launch Technology Program to investigate the effects of high-speed nozzle geometries on the nozzle internal flow and the surrounding boattail regions. These computations span the very difficult transonic flight regime, with shock-induced separations and strong adverse pressure gradients. External afterbody and internal nozzle pressure distributions computed with the Wind code are compared with experimental data. A range of turbulence models were examined in Wind, including an Explicit Algebraic Stress model (EASM). Computations on two nozzle geometries have been completed at freestream Mach numbers ranging from 0.6 to 0.9, driven by nozzle pressure ratios (NPR) ranging from 2.9 to 5. Results obtained on converging-only geometry indicate reasonable agreement to experimental data, with the EASM and Shear Stress Transport (SST) turbulence models providing the best agreement. Calculations completed on a converging-diverging geometry involving large-scale internal flow separation did not converge to a true steady-state solution when run with variable timestepping (steady-state). Calculations obtained using constant timestepping (time-accurate) indicate less variations in flow properties compared with steady-state solutions. This failure to converge to a steady-state solution was found to be the result of difficulties in using variable time-stepping with large-scale separations present in the flow. Nevertheless, time-averaged boattail surface pressure coefficient and internal nozzle pressures show fairly good agreement with experimental data. The SST turbulence model demonstrates the best over-all agreement with experimental data.

  4. Evaluation of occupational exposure to infrasonic noise in Poland.

    PubMed

    Pawlaczyk-Luszczyńska, M

    1999-01-01

    A short review of infrasound sources and effects on humans is presented. Polish standard PN-86/N-01338 and international standards ISO 7196:1995 and ISO 9612:1997 concerning the measuring techniques of infrasonic noise are described. The results of infrasonic noise measurements performed in the work environment in Poland are discussed. The study concerned the noise emitted by 124 different types of industrial machinery, appliances and means of transport. The measurements were made in typical working conditions with reference to Polish and international standards. The sound pressure levels exceeding Polish admissible values for: (a) workers' health protection were found in 5 (4.0%) cases, (b) ensuring proper conditions for performing basic functions in observational dispatcher cabins etc. in 77 (62.1%) cases; and (c) administration premises, design offices etc. in 92 (74.2%) cases. The admissible sound pressure levels for workers' health protection are in fact the permissible levels for hearing protection, however they do not correspond with the hearing threshold of infrasound the G-weighting characteristic is associated with. The hearing threshold of infrasound (G86 curve) was exceeded in 66.9% of all the industrial machinery and means of transport under study.

  5. Measurements of Heat Transfer, Flow, and Pressures in a Simulated Turbine Blade Internal Cooling Passage

    NASA Technical Reports Server (NTRS)

    Russell, Louis M.; Thurman, Douglas R.; Poinsatte, Philip E.; Hippensteele, Steven A.

    1998-01-01

    An experimental study was made to obtain quantitative information on heat transfer, flow, and pressure distribution in a branched duct test section that had several significant features of an internal cooling passage of a turbine blade. The objective of this study was to generate a set of experimental data that could be used for validation of computer codes that would be used to model internal cooling. Surface heat transfer coefficients and entrance flow conditions were measured at nominal entrance Reynolds numbers of 45,000, 335,000, and 726,000. Heat transfer data were obtained by using a steady-state technique in which an Inconel heater sheet is attached to the surface and coated with liquid crystals. Visual and quantitative flow-field data from particle image velocimetry measurements for a plane at midchannel height for a Reynolds number of 45,000 were also obtained. The flow was seeded with polystyrene particles and illuminated by a laser light sheet. Pressure distribution measurements were made both on the surface with discrete holes and in the flow field with a total pressure probe. The flow-field measurements yielded flow-field velocities at selected locations. A relatively new method, pressure sensitive paint, was also used to measure surface pressure distribution. The pressure paint data obtained at Reynolds numbers of 335,000 and 726,000 compared well with the more standard method of measuring pressures by using discrete holes.

  6. Geotechnical Feasibility Analysis of Compressed Air Energy Storage (CAES) in Bedded Salt Formations: a Case Study in Huai'an City, China

    NASA Astrophysics Data System (ADS)

    Zhang, Guimin; Li, Yinping; Daemen, Jaak J. K.; Yang, Chunhe; Wu, Yu; Zhang, Kai; Chen, Yanlong

    2015-09-01

    The lower reaches of the Yangtze River is one of the most developed regions in China. It is desirable to build compressed air energy storage (CAES) power plants in this area to ensure the safety, stability, and economic operation of the power network. Geotechnical feasibility analysis was carried out for CAES in impure bedded salt formations in Huai'an City, China, located in this region. First, geological investigation revealed that the salt groups in the Zhangxing Block meet the basic geological conditions for CAES storage, even though the possible unfavorable characteristics of the salt formations include bedding and different percentages of impurities. Second, mechanical tests were carried out to determine the mechanical characteristics of the bedded salt formations. It is encouraging that the samples did not fail even when they had undergone large creep deformation. Finally, numerical simulation was performed to evaluate the stability and volume shrinkage of the CAES under the following conditions: the shape of a single cavern is that of a pear; the width of the pillar is adopted as two times the largest diameter; three regular operating patterns were adopted for two operating caverns (internal pressure 9-10.5 MPa, 10-11.5 MPa, and 11-12.5 MPa), while the other two were kept at high pressure (internal pressure 10.5, 11.5, and 12.5 MPa) as backups; an emergency operating pattern in which two operating caverns were kept at atmospheric pressure (0.1 MPa) for emergency while the backups were under operation (9-10.5 MPa), simulated for 12 months at the beginning of the 5th year. The results of the analysis for the plastic zone, displacement, and volume shrinkage support the feasibility of the construction of an underground CAES power station.

  7. Internal and External Pressures: How Does an Organic Cotton Production Network Learn to Keep Its Hybrid Nature?

    ERIC Educational Resources Information Center

    Turcato, Carolina; Barin-Cruz, Luciano; Pedrozo, Eugenio Avila

    2012-01-01

    Purpose: This study aims to investigate how an organic cotton production network learns to maintain its hybrid network and its sustainability in the face of internal and external pressures. Design/methodology/approach: A qualitative case study was conducted in Justa Trama, a Brazilian-based organic cotton production network formed by six members…

  8. 49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...

  9. 49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...

  10. 49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...

  11. 49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...

  12. Deployment of Large-Size Shell Constructions by Internal Pressure

    NASA Astrophysics Data System (ADS)

    Pestrenin, V. M.; Pestrenina, I. V.; Rusakov, S. V.; Kondyurin, A. V.

    2015-11-01

    A numerical study on the deployment pressure (the minimum internal pressure bringing a construction from the packed state to the operational one) of large laminated CFRP shell structures is performed using the ANSYS engineering package. The shell resists both membrane and bending deformations. Structures composed of shell elements whose median surface has an involute are considered. In the packed (natural) states of constituent elements, the median surfaces coincide with their involutes. Criteria for the termination of stepwise solution of the geometrically nonlinear problem on determination of the deployment pressure are formulated, and the deployment of cylindrical, conical (full and truncated cones), and large-size composite shells is studied. The results obtained are shown by graphs illustrating the deployment pressure in relation to the geometric and material parameters of the structure. These studies show that large pneumatic composite shells can be used as space and building structures, because the deployment pressure in them only slightly differs from the excess pressure in pneumatic articles made from films and soft materials.

  13. Temperature-dependent selective oxidation processes for Ni-5Cr and Ni-4Al

    DOE PAGES

    Kruska, Karen; Schreiber, Daniel K.; Olszta, Matthew J.; ...

    2018-05-09

    The selective oxidation of Ni-5Cr and Ni-4 Al alloys is evaluated during high (800 °C) and low (420 °C) temperature exposures with the oxygen partial pressure moderated by a Ni/NiO powder buffer. Internal oxidation of Cr and Al is observed throughout the matrix and at grain boundaries at 800 °C accompanied by the ejection of Ni onto the surface for both. At 420 °C, matrix internal oxidation was eliminated and only Ni-4 Al exhibited intergranular (IG) oxidation. Surprisingly, a protective surface oxide rapidly formed for Ni-5Cr blocking IG oxidation. Finally, this is contradictory to results in 330–360 °C hydrogenated watermore » environments where both alloys show IG oxidation.« less

  14. Temperature-dependent selective oxidation processes for Ni-5Cr and Ni-4Al

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruska, Karen; Schreiber, Daniel K.; Olszta, Matthew J.

    The selective oxidation of Ni-5Cr and Ni-4 Al alloys is evaluated during high (800 °C) and low (420 °C) temperature exposures with the oxygen partial pressure moderated by a Ni/NiO powder buffer. Internal oxidation of Cr and Al is observed throughout the matrix and at grain boundaries at 800 °C accompanied by the ejection of Ni onto the surface for both. At 420 °C, matrix internal oxidation was eliminated and only Ni-4 Al exhibited intergranular (IG) oxidation. Surprisingly, a protective surface oxide rapidly formed for Ni-5Cr blocking IG oxidation. Finally, this is contradictory to results in 330–360 °C hydrogenated watermore » environments where both alloys show IG oxidation.« less

  15. Validation of the Pangao PG-800B26 upper arm blood pressure monitor in the general population according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Chen, Liang; Li, Jiyu; Wen, Jing; Guo, Changfeng; Zhang, Jingying; Yu, Zhen

    2018-02-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Pangao PG-800B26 for home blood pressure monitoring according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. Systolic and diastolic blood pressures were measured sequentially in 33 and 85 adults, respectively, on the basis of the ESH-IP and BHS protocols using a mercury sphygmomanometer (two observers) and the device (one supervisor). The procedures and analysis methods of the protocols were followed precisely. The device fulfilled the criteria of the ESH-IP, with device-observer differences of 1.01±5.16 and -0.58±4.17 mmHg for systolic and diastolic blood pressure, respectively. Furthermore, the A/A grade of the BHS protocol was also achieved for overall grading and for the three pressure levels, with average differences of 0.85±6.35 and -0.15±5.65 mmHg for systolic and diastolic blood pressure, respectively, which also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800B26 fulfilled the criteria of the ESH-IP 2010 and achieved the A/A grade of the BHS protocol, and hence can be recommended for home use in adults.

  16. The biomechanical characteristics of wearing FitFlop™ sandals highlight significant alterations in gait pattern: a comparative study.

    PubMed

    James, Darren C; Farmer, Laura J; Sayers, Jason B; Cook, David P; Mileva, Katya N

    2015-05-01

    The net contribution of all muscles that act about a joint can be represented as an internal joint moment profile. This approach may be advantageous when studying footwear-induced perturbations during walking since the contribution of the smaller deeper muscles that cross the ankle joint cannot be evaluated with surface electromyography. Therefore, the present study aimed to advance the understanding of FitFlop™ footwear interaction by investigating lower extremity joint moment, and kinematic and centre of pressure profiles during gait. 28 healthy participants performed 5 walking trials in 3 conditions: a FitFlop™ sandal, a conventional sandal and an athletic trainer. Three-dimensional ankle joint, and sagittal plane knee and hip joint moments, as well as corresponding kinematics and centre of pressure trajectories were evaluated. FitFlop™ differed significantly to both the conventional sandal and athletic trainer in: average anterior position of centre of pressure trajectory (P<0.0001) and peak hip extensor moment (P=0.001) during early stance; average medial position of centre of pressure trajectory during late stance; peak ankle dorsiflexion and corresponding range of motion; peak plantarflexor moment and total negative work performed at the ankle (all P<0.0001). The present findings demonstrate that FitFlop™ footwear significantly alters the gait pattern of wearers. An anterior displacement of the centre of pressure trajectory during early stance is the primary response to the destabilising effect of the mid-sole technology, and this leads to reductions in sagittal plane ankle joint range of motion and corresponding kinetics. Future investigations should consider the clinical implications of these findings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options

    NASA Technical Reports Server (NTRS)

    Vasquez, Arturo

    2011-01-01

    An advanced reactant pressure regulator with an internal ejector reactant circulation pump has been developed to support NASA's future fuel cell power systems needs. These needs include reliable and safe operation in variable-gravity environments, and for exploration activities with both manned and un manned vehicles. This product was developed for use in Proton Exchange Membrane Fuel Cell (PEMFC) power plant reactant circulation systems, but the design could also be applied to other fuel cell system types, (e.g., solid-oxide or alkaline) or for other gas pressure regulation and circulation needs. The regulator design includes porting for measurement of flow and pressure at key points in the system, and also includes several fuel cell system integration options. NASA has recognized ejectors as a viable alternative to mechanical pumps for use in spacecraft fuel cell power systems. The ejector motive force is provided by a variable, high-pressure supply gas that travels through the ejector s jet nozzle, whereby the pressure energy of the fluid stream is converted to kinetic energy in the gas jet. The ejector can produce circulation-to-consumption-flow ratios that are relatively high (2-3 times), and this phenomenon can potentially (with proper consideration of the remainder of the fuel cell system s design) be used to provide completely for reactant pre-humidification and product water removal in a fuel cell system. Specifically, a custom pressure regulator has been developed that includes: (1) an ejector reactant circulation pump (with interchangeable jet nozzles and mixer sections, gas-tight sliding and static seals in required locations, and internal fluid porting for pressure-sensing at the regulator's control elements) and (2) internal fluid porting to allow for flow rate and system pressure measurements. The fluid porting also allows for inclusion of purge, relief, and vacuum-breaker check valves on the regulator assembly. In addition, this regulator could also be used with NASA's advanced nonflow-through fuel cell power systems by simply incorporating a jet nozzle with an appropriate nozzle diameter.

  18. Tropospheric delays from GNSS for application in coastal altimetry

    NASA Astrophysics Data System (ADS)

    Fernandes, M. Joana; Pires, Nelson; Lázaro, Clara; Nunes, Alexandra L.

    2013-04-01

    In the scope of the development of an improved methodology for the computation of the wet tropospheric correction for coastal altimetry, based on the use of tropospheric delays derived from GNSS (Global Navigation Satellite Systems), various studies have been conducted aiming to improve the estimation, at global scale, of GNSS-derived tropospheric delays.Amongst these studies, two are presented in this paper: (1) a global assessment of zenith total delays (ZTD) determined at international data centres such as EPN (EUREF Permanent Network) and IGS (International GNSS Service) by comparison with ZTD solutions computed at the University of Porto (U.Porto) using state-of-the-art methodologies and ZTD estimated from ERA Interim, the latest reanalysis dataset from ECMWF (European Centre for Medium-Range Weather Forecasts), (2) evaluation of the accuracy of the hydrostatic component of the tropospheric delay (zenith hydrostatic delay, ZHD) estimation from different sources of surface pressure.When compared with ERA Interim, both IGS and U.Porto ZTD are homogeneous with a mean standard deviation of the differences, for all analysed sites, of 12 mm. The U.Porto and IGS ZTD agree within 4 mm (1σ), while for EPN the same result is only valid for the period after November 2006. Before that date, the EPN solutions are slightly degraded and require an adequate correction.Aiming to evaluate the accuracy of ZHD determination from various sources of atmospheric pressure, a study is presented that compares ZHD values determined with in situ measurements of surface pressure at a global set of 63 coastal barometric sites (GNSS stations), the corresponding values obtained from ECMWF operational model, ERA Interim sea level pressure (SLP) and ZHD from the Vienna Mapping Functions 1 (VMF1).Results show that the global grids of sea level pressure provided by ECMWF operational model, either at 0.25° or 0.125° spacing, or the ERA Interim reanalysis product at 1.5°, allow the estimation of the hydrostatic component of the tropospheric delay with an accuracy of 1 to 3 mm at global scale, provided an adequate model for the height dependence of atmospheric pressure is adopted. In comparison, for VMF1 grids provided at 2.5° spacing, although the overall accuracy of ZHD estimation is 2-4 mm in most sites, in regions with high variability and strong seasonal signal in the surface pressure, VMF1 can reveal errors with a clear annual pattern and epochs for which the error exceeds the centimetre level. When used to estimate the wet component of the tropospheric delay (zenith wet delay, ZWD) for coastal altimetry, these errors can translate into errors of similar magnitude in sea level studies.

  19. The effect of moderate running on foot posture index and plantar pressure distribution in male recreational runners.

    PubMed

    Escamilla-Martínez, Elena; Martínez-Nova, Alfonso; Gómez-Martín, Beatriz; Sánchez-Rodríguez, Raquel; Fernández-Seguín, Lourdes María

    2013-01-01

    Fatigue due to running has been shown to contribute to changes in plantar pressure distribution. However, little is known about changes in foot posture after running. We sought to compare the foot posture index before and after moderate exercise and to relate any changes to plantar pressure patterns. A baropodometric evaluation was made, using the FootScan platform (RSscan International, Olen, Belgium), of 30 men who were regular runners and their foot posture was examined using the Foot Posture Index before and after a 60-min continuous run at a moderate pace (3.3 m/sec). Foot posture showed a tendency toward pronation after the 60-min run, gaining 2 points in the foot posture index. The total support and medial heel contact areas increased, as did pressures under the second metatarsal head and medial heel. Continuous running at a moderate speed (3.3 m/sec) induced changes in heel strike related to enhanced pronation posture, indicative of greater stress on that zone after physical activity. This observation may help us understand the functioning of the foot, prevent injuries, and design effective plantar orthoses in sport.

  20. On the internal structure of relativistic jets collimated by ambient gas pressure

    NASA Astrophysics Data System (ADS)

    Beskin, V. S.; Chernoglazov, A. V.; Kiselev, A. M.; Nokhrina, E. E.

    2017-12-01

    Recent progress in very long baseline interferometry (VLBI) observations of relativistic jets outflowing from active galactic nuclei gives us direct information about jet width rjet(l) dependence on the distance l from the 'central engine'. Being the missing link in previous works, this relation opens the possibility of determining the internal structure of a jet. In this article, we consider a relativistic jet submerged in an external medium with finite gas pressure Pext. Neither an external magnetic field nor an infinitely thin current sheet will be assumed. This approach allows us to construct a reasonable solution in which both the magnetic field and the flow velocity vanish at the jet boundary r = rjet. In particular, the connection between external gas pressure and internal structure of a relativistic jet is determined.

  1. Material Usage in High Pressure Oxygen Systems for the International Space Station

    NASA Technical Reports Server (NTRS)

    Kravchenko, Michael; Sievers, D. Elliott

    2014-01-01

    The Nitrogen/Oxygen Recharge System (NORS) for the International Space Station (ISS) Program was required as part of the Space Shuttle retirement efforts to sustain the ISS life support systems. The system is designed around a 7000 psia Oxygen or Nitrogen Recharge Tank Assembly which is able to be utilized both internally and externally to the ISS. Material selection and usage were critical to ensure oxygen compatibility for the design, while taking into consideration toxicity, weldability, brazability and general fabrication and assembly techniques. The system uses unique hardware items such a composite overwrap pressure vessel (COPV), high pressure mechanical gauges, compact regulators and valves, quick disconnects, metal tubing and flexhoses. Numerous challenges and anomalies were encountered due to the exotic nature of this project which will be discussed in detail. The knowledge gained from these anomalies and failure resolutions can be applied to more than space applications, but can also be applicable to industry pressurized systems.

  2. How Internally Coupled Ears Generate Temporal and Amplitude Cues for Sound Localization.

    PubMed

    Vedurmudi, A P; Goulet, J; Christensen-Dalsgaard, J; Young, B A; Williams, R; van Hemmen, J L

    2016-01-15

    In internally coupled ears, displacement of one eardrum creates pressure waves that propagate through air-filled passages in the skull and cause displacement of the opposing eardrum, and conversely. By modeling the membrane, passages, and propagating pressure waves, we show that internally coupled ears generate unique amplitude and temporal cues for sound localization. The magnitudes of both these cues are directionally dependent. The tympanic fundamental frequency segregates a low-frequency regime with constant time-difference magnification from a high-frequency domain with considerable amplitude magnification.

  3. Nonlinear Analysis and Post-Test Correlation for a Curved PRSEUS Panel

    NASA Technical Reports Server (NTRS)

    Gould, Kevin; Lovejoy, Andrew E.; Jegley, Dawn; Neal, Albert L.; Linton, Kim, A.; Bergan, Andrew C.; Bakuckas, John G., Jr.

    2013-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept, developed by The Boeing Company, has been extensively studied as part of the National Aeronautics and Space Administration's (NASA s) Environmentally Responsible Aviation (ERA) Program. The PRSEUS concept provides a light-weight alternative to aluminum or traditional composite design concepts and is applicable to traditional-shaped fuselage barrels and wings, as well as advanced configurations such as a hybrid wing body or truss braced wings. Therefore, NASA, the Federal Aviation Administration (FAA) and The Boeing Company partnered in an effort to assess the performance and damage arrestments capabilities of a PRSEUS concept panel using a full-scale curved panel in the FAA Full-Scale Aircraft Structural Test Evaluation and Research (FASTER) facility. Testing was conducted in the FASTER facility by subjecting the panel to axial tension loads applied to the ends of the panel, internal pressure, and combined axial tension and internal pressure loadings. Additionally, reactive hoop loads were applied to the skin and frames of the panel along its edges. The panel successfully supported the required design loads in the pristine condition and with a severed stiffener. The panel also demonstrated that the PRSEUS concept could arrest the progression of damage including crack arrestment and crack turning. This paper presents the nonlinear post-test analysis and correlation with test results for the curved PRSEUS panel. It is shown that nonlinear analysis can accurately calculate the behavior of a PRSEUS panel under tension, pressure and combined loading conditions.

  4. Experimental analysis of large capacity MR dampers with short- and long-stroke

    NASA Astrophysics Data System (ADS)

    Zemp, René; de la Llera, Juan Carlos; Weber, Felix

    2014-12-01

    The purpose of this article is to study and characterize experimentally two magneto-rheological dampers with short- and long-stroke, denoted hereafter as MRD-S and MRD-L. The latter was designed to improve the Earthquake performance of a 21-story reinforced concrete building equipped with two 160 ton tuned pendular masses. The MRD-L has a nominal force capacity of 300 kN and a stroke of ±1 m; the MRD-S has a nominal force capacity of 150 kN, and a stroke of ±0.1 m. The MRD-S was tested with two different magneto-rheological and one viscous fluid. Due to the presence of Eddy currents, both dampers show a time lag between current intensity and damper force as the magnetization on the damper changes in time. Experimental results from the MRD-L show a force drop-off behavior. A decrease in active-mode forces due to temperature increase is also analyzed for the MRD-S and the different fluids. Moreover, the observed increase in internal damper pressure due to energy dissipation is evaluated for the different fluids in both dampers. An analytical model to predict internal pressure increase in the damper is proposed that includes as a parameter the concentration of magnetic particles inside the fluid. Analytical dynamic pressure results are validated using the experimental tests. Finally, an extended Bingham fluid model, which considers compressibility of the fluid, is also proposed and validated using damper tests.

  5. Fake It 'Til You Make It: Pressures to Measure Up in Surgical Training.

    PubMed

    Patel, Priyanka; Martimianakis, Maria A; Zilbert, Nathan R; Mui, Carween; Hammond Mobilio, Melanie; Kitto, Simon; Moulton, Carol-Anne

    2018-05-01

    Expectations of certainty and confidence in surgical culture are a source of internal conflict for surgeons and learners, with surgeons describing a pressure to project an image that is, at times, inconsistent with how they feel internally. The authors explored surgical residents' perceptions of "impression management" and its effects on surgical judgment and decision making. The authors used a constructivist grounded theory approach to conduct and analyze 15 semistructured interviews with general surgery trainees at an urban Canadian academic health center between 2012 and 2014. Interviews explored impression management in the context of resident learning and performance. Analysis was inductive, whereby emergent themes contributed to a developing conceptual framework, and deductive, using an existing theory of impression management. Residents described sensing an "expectation" to portray an image aligned with the ideal surgical stereotype of confidence and certainty, and shared strategies used to mirror this image. Impression management strategies were used to portray an image of competence, with the aim to improve access to teaching and evaluations. Unintended consequences of impression management on decision making, patient safety, and resident wellness were identified. These findings contribute to a deeper understanding of the potential impact of the sociocultural context on residency training, and provide a language allowing for more explicit discussions about the impact of surgical culture on trainee behaviors. Translation includes formal instruction of these concepts in the curriculum so that trainees better recognize, reflect on, and cope with the pressures to perform in front of others.

  6. Tokamak Equilibrium Reconstruction with MSE-LS Data in DIII-D

    NASA Astrophysics Data System (ADS)

    Lao, L.; Grierson, B.; Burrell, K. H.

    2016-10-01

    Equilibrium analysis of plasmas in DIII-D using EFIT was upgraded to include the internal magnetic field determined from spectroscopic measurements of motional-Stark-effect line-splitting (MSE-LS). MSE-LS provides measurements of the magnitude of the internal magnetic field, rather than the pitch angle as provided by MSE line-polarization (MSE-LP) used in most tokamaks to date. EFIT MSE-LS reconstruction algorithms and verifications are described. The capability of MSE-LS to provide significant constraints on the equilibrium analysis is evaluated. Reconstruction results with both synthetic and experimental MSE-LS data from 10 DIII-D discharges run over a range of conditions show that MSE-LS measurements can contribute to the equilibrium reconstruction of pressure and safety factor profiles. Adequate MSE-LS measurement accuracy and number of spatial locations are necessary. The 7 available experimental measurements provide useful additional constraints when used with other internal measurements. Using MSE-LS as the only internal measurement yields less current profile information. Work supported by the PPPL Subcontract S013769-F and US DOE under DE-FC02-04ER54698.

  7. Study of parameter of nonlinearity in 2-chloroethanol with 2-dimethylethanolamine/2-diethylethanolamine at different temperatures

    NASA Astrophysics Data System (ADS)

    Awasthi, Anjali; Awasthi, Aashees

    2017-06-01

    The acoustic non-linearity parameter (B/A) for binary mixtures of 2-chloroethanol with 2-dimethylethanolamine (2-DMAE) and 2-diethylethanolamine (2-DEAE) are evaluated using Tong Dong, Beyer and Beyer-Tong Dong coefficients at varying concentrations and temperatures ranging from 293.15 to 313.15 K. The nonlinearity parameter is used to calculate various molecular properties such as internal pressure, cohesive energy density, Van der waals' constant, distance of closest approach, diffusion coefficient and rotational correlation time. Additionally, the intermediate quantities like temperature and pressure derivatives of sound velocity and phase shift parameter as a function of temperature are also deduced. The extent of intermolecular interactions, anharmonicity and structural configuration of the binaries under investigation are discussed in terms of excess non-linearity parameter (B/A)E.

  8. Sustainability Assessment of indicators for integrated water resources management.

    PubMed

    Pires, A; Morato, J; Peixoto, H; Botero, V; Zuluaga, L; Figueroa, A

    2017-02-01

    The scientific community strongly recommends the adoption of indicators for the evaluation and monitoring of progress towards sustainable development. Furthermore, international organizations consider that indicators are powerful decision-making tools. Nevertheless, the quality and reliability of the indicators depends on the application of adequate and appropriate criteria to assess them. The general objective of this study was to evaluate how indicators related to water use and management perform against a set of sustainability criteria. Our research identified 170 indicators related to water use and management. These indicators were assessed by an international panel of experts that evaluated whether they fulfil the four sustainability criteria: social, economic, environmental, and institutional. We employed an evaluation matrix that classified all indicators according to the DPSIR (Driving Forces, Pressures, States, Impacts and Responses) framework. A pilot study served to test and approve the research methodology before carrying out the full implementation. The findings of the study show that 24 indicators comply with the majority of the sustainability criteria; 59 indicators are bi-dimensional (meaning that they comply with two sustainability criteria); 86 are one-dimensional indicators (fulfilling just one of the four sustainability criteria) and one indicator do not fulfil any of the sustainability criteria. Copyright © 2016. Published by Elsevier B.V.

  9. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    PubMed

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a limited sample size prevented formal validation.

  10. Touch Sensor Responds to Contact Pressure

    NASA Technical Reports Server (NTRS)

    Bejczy, A. K.

    1982-01-01

    Optical tactile sensor for mechanical hands senses contact pressure via change in light reflected from an elastic covering. Pressure against a cell cover causes distortion, which changes internal reflection of light. Change is sensed by detector, and output signal informs operator of contact. The greater the pressure and distortion, the greater the change in light reflection.

  11. 77 FR 41045 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... deck. This AD requires replacing the low-pressure oxygen hoses with non-conductive low-pressure oxygen... through the low-pressure oxygen hose internal anti-collapse spring, which can cause the low-pressure oxygen hose to melt or burn, and a consequent oxygen-fed fire in the flight compartment. DATES: This AD...

  12. 77 FR 37377 - High Pressure Steel Cylinders From the People's Republic of China: Antidumping Duty Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-977] High Pressure Steel... Department is issuing an antidumping duty order on high pressure steel cylinders from the People's Republic... determination of material injury to a U.S. industry.\\1\\ \\1\\ See High Pressure Steel Cylinders from China...

  13. 77 FR 1060 - High Pressure Steel Cylinders From the People's Republic of China: Postponement of Final...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-09

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-977] High Pressure Steel... (``Department'') initiated an antidumping duty investigation on high pressure steel cylinders from the People's... investigation is currently due 75 days after the date of the Preliminary Determination.\\3\\ \\1\\ See High Pressure...

  14. 78 FR 55059 - High Pressure Steel Cylinders from the People's Republic of China: Rescission of Countervailing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-09

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-978] High Pressure Steel... duty order on high pressure steel cylinders (cylinders) from the People's Republic of China (PRC) for... High Pressure Steel Cylinders from the People's Republic of China.'' \\3\\ See BTIC's August 23, 2013...

  15. 75 FR 17124 - Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of Antidumping Duty Finding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-059] Pressure Sensitive Plastic... antidumping duty finding on pressure sensitive plastic tape (PSP Tape) from Italy would be likely to lead to... of the margins likely to prevail were the finding to be revoked. See Pressure Sensitive Plastic Tape...

  16. Prosthetic occlusive device for an internal passageway

    NASA Technical Reports Server (NTRS)

    Tenney, J. B., Jr. (Inventor)

    1983-01-01

    An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.

  17. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforcedmore » composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) Pipe diameter sizes range from 50.8 mm (2 in.) through 1,219.2 mm (48 in.). The most common size range for 80% to 90% of operators surveyed is 508 mm to 762 mm (20 in. to 30 in.), with 95% using 558.8 mm (22 in.) pipe. An evaluation of potential repair methods clearly indicates that the project should continue to focus on the development of a repair process involving the use of GMAW welding and on the development of a repair process involving the use of fiber-reinforced composite liners.« less

  18. Independent Assessment of Instrumentation for ISS On-Orbit NDE. Volume 1

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I

    2013-01-01

    International Space Station (ISS) Structural and Mechanical Systems Manager, requested that the NASA Engineering and Safety Center (NESC) provide a quantitative assessment of commercially available nondestructive evaluation (NDE) instruments for potential application to the ISS. This work supports risk mitigation as outlined in the ISS Integrated Risk Management Application (IRMA) Watch Item #4669, which addresses the requirement for structural integrity after an ISS pressure wall leak in the event of a penetration due to micrometeoroid or debris (MMOD) impact. This document contains the outcome of the NESC assessment.

  19. Manufacturing methods of a composite cell case for a Ni-Cd battery

    NASA Technical Reports Server (NTRS)

    Bauer, J. L.; Bogner, R. S.; Lowe, E. P.; Orlowski, E.

    1979-01-01

    Graphite epoxy material for a nickel cadmium battery cell case has been evaluated and determined to perform in the simulated environment of the battery. The basic manufacturing method requires refinement to demonstrate production feasibility. The various facets of production scale-up, i.e., process and tooling development together with material and process control, have been integrated into a comprehensive manufacturing process that assures production reproducibility and product uniformity. Test results substantiate that a battery cell case produced from graphite epoxy pre-impregnated material utilizing internal pressure bag fabrication method is feasible.

  20. Influences of geological parameters to probabilistic assessment of slope stability of embankment

    NASA Astrophysics Data System (ADS)

    Nguyen, Qui T.; Le, Tuan D.; Konečný, Petr

    2018-04-01

    This article considers influences of geological parameters to slope stability of the embankment in probabilistic analysis using SLOPE/W computational system. Stability of a simple slope is evaluated with and without pore–water pressure on the basis of variation of soil properties. Normal distributions of unit weight, cohesion and internal friction angle are assumed. Monte Carlo simulation technique is employed to perform analysis of critical slip surface. Sensitivity analysis is performed to observe the variation of the geological parameters and their effects on safety factors of the slope stability.

  1. Independent Assessment of Instrumentation for ISS On-Orbit NDE. Volume 2; Appendices

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.

    2013-01-01

    International Space Station (ISS) Structural and Mechanical Systems Manager, requested that the NASA Engineering and Safety Center (NESC) provide a quantitative assessment of commercially available nondestructive evaluation (NDE) instruments for potential application to the ISS. This work supports risk mitigation as outlined in the ISS Integrated Risk Management Application (IRMA) Watch Item #4669, which addresses the requirement for structural integrity after an ISS pressure wall leak in the event of a penetration due to micrometeoroid or debris (MMOD) impact. This document contains the appendices the final report.

  2. Evaluating the cost effectiveness of environmental projects: Case studies in aerospace and defense

    NASA Technical Reports Server (NTRS)

    Shunk, James F.

    1995-01-01

    Using the replacement technology of high pressure waterjet decoating systems as an example, a simple methodology is presented for developing a cost effectiveness model. The model uses a four-step process to formulate an economic justification designed for presentation to decision makers as an assessment of the value of the replacement technology over conventional methods. Three case studies from major U.S. and international airlines are used to illustrate the methodology and resulting model. Tax and depreciation impacts are also presented as potential additions to the model.

  3. How Much Does a Half-Kilogram of Water "Weigh"?

    NASA Astrophysics Data System (ADS)

    Koumaras, Panagiotis; Pierratos, Theodoros

    2015-03-01

    Many educators have utilized the phenomenon of the so-called "hydrostatic paradox" to actively engage students in classroom instructional activities related to hydrostatic equilibrium.1 Various approaches requiring different levels of mathematical knowledge have been proposed in the literature to provide students clear explanations of this paradox.2 However, these attempts take for granted that students have already been taught and have internalized the concepts of force and pressure. The hydrostatic paradox is then usually introduced as an application problem for the evaluation of the knowledge acquired.

  4. Fluid Analysis and Improved Structure of an ATEG Heat Exchanger Based on Computational Fluid Dynamics

    NASA Astrophysics Data System (ADS)

    Tang, Z. B.; Deng, Y. D.; Su, C. Q.; Yuan, X. H.

    2015-06-01

    In this study, a numerical model has been employed to analyze the internal flow field distribution in a heat exchanger applied for an automotive thermoelectric generator based on computational fluid dynamics. The model simulates the influence of factors relevant to the heat exchanger, including the automotive waste heat mass flow velocity, temperature, internal fins, and back pressure. The result is in good agreement with experimental test data. Sensitivity analysis of the inlet parameters shows that increase of the exhaust velocity, compared with the inlet temperature, makes little contribution (0.1 versus 0.19) to the heat transfer but results in a detrimental back pressure increase (0.69 versus 0.21). A configuration equipped with internal fins is proved to offer better thermal performance compared with that without fins. Finally, based on an attempt to improve the internal flow field, a more rational structure is obtained, offering a more homogeneous temperature distribution, higher average heat transfer coefficient, and lower back pressure.

  5. Experimental investigation of a Mach 6 fixed-geometry inlet featuring a swept external-internal compression flow field

    NASA Technical Reports Server (NTRS)

    Torrence, M. G.

    1975-01-01

    An investigation of a fixed-geometry, swept external-internal compression inlet was conducted at a Mach number of 6.0 and a test-section Reynolds number of 1.55 x 10 to the 7th power per meter. The test conditions was constant for all runs with stagnation pressure and temperature at 20 atmospheres and 500 K, respectively. Tests were made at angles of attack of -5 deg, 0 deg, 3 deg, and 5 deg. Measurements consisted of pitot- and static-pressure surveys in inlet throat, wall static pressures, and surface temperatures. Boundary-layer bleed was provided on the centerbody and on the cowl internal surface. The inlet performance was consistently high over the range of the angle of attack tested, with an overall average total pressure recovery of 78 percent and corresponding adiabatic kinetic-energy efficiency of 99 percent. The inlet throat flow distribution was uniform and the Mach number and pressure level were of the correct magnitude for efficient combustor design. The utilization of a swept compression field to meet the starting requirements of a fixed-geometry inlet produced neither flow instability nor a tendency to unstart.

  6. Occupant kinematics and estimated effectiveness of side airbags in pole side impacts using a human FE model with internal organs.

    PubMed

    Hayashi, Shigeki; Yasuki, Tsuyoshi; Kitagawa, Yuichi

    2008-11-01

    When a car collides against a pole-like obstacle, the deformation pattern of the vehicle body-side tends to extend to its upper region. A possible consequence is an increase of loading to the occupant thorax. Many studies have been conducted to understand human thoracic responses to lateral loading, and injury criteria have been developed based on the results. However, injury mechanisms, especially those of internal organs, are not well understood. A human body FE model was used in this study to simulate occupant kinematics in a pole side impact. Internal organ parts were introduced into the torso model, including their geometric features, material properties and connections with other tissues. The mechanical responses of the model were validated against PMHS data in the literature. Although injury criterion for each organ has not been established, pressure level and its changes can be estimated from the organ models. Finite element simulations were conducted assuming a case where a passenger vehicle collides against a pole at 29km/h. Occupant kinematics, force-deformation responses and pressure levels were compared between cases with and without side airbag deployment. The results indicated that strain to the ribs and pressure to the organs was smaller with side airbag deployment. The side airbag widened the contact area at the torso, helping to distribute the force to the shoulder, arm and chest. Such distributed force helped generate relatively smaller deformation in the ribs. Furthermore, the side airbag deployment helped restrict the spine displacement. The smaller displacement contributed to lowering the magnitude of contact force between the torso and the door. The study also examined the correlations between the pressure levels in the internal organs, rib deflection, and V*C of chest. The study found that the V*C(t) peak appeared to be synchronized with the organ pressure peak, suggesting that the pressure level of the internal organs could be one possible indicator to estimate their injury risk.

  7. Flow-independent dynamics in aneurysms: intra-aneurysm pressure measurements following complete flow cessation in internal carotid artery aneurysms.

    PubMed

    Qureshi, Adnan I; Qureshi, Mushtaq H; Mohindroo, Tanya; Khan, Asif A; Dingmann, Kayla; Sherr, Gregory T; Suri, M Fareed K

    2014-12-01

    To determine if complete flow obliteration by covered stents reduces intra-aneurysm pressures in internal carotid artery (ICA) aneurysms. A single lumen microcatheter was placed into the aneurysm sac prior to covered stent deployment in 3 patients and connected to a pressure monitoring system. The intra-aneurysm pressure was continuously monitored, and readings were recorded prior to and immediately after stent deployment and at 5-minute intervals up to 20 minutes after stent placement. Complete occlusion of flow into the aneurysms was confirmed by carotid angiography. There was no change in mean pressure within the aneurysm before and immediately after stent placement (80 mmHg) in any patient, nor was there a change in waveform of the intra-aneurysm pressure recording. The average of intra-aneurysm pressures among the 3 patients was higher (99 mmHg) at 10 and 15 minutes after stent placement. In 2 patients, the microcatheter was retracted into the parent arterial lumen; no difference in pressure was noted. Our observations suggest no change in the pressures within the aneurysm after complete flow cessation (flow-independent). These findings may assist clinicians in better understanding aneurysm hemodynamics and rupture after covered stent deployment.

  8. Lack of recognition of genetic biodiversity: International policy and its implementation in Baltic Sea marine protected areas.

    PubMed

    Laikre, Linda; Lundmark, Carina; Jansson, Eeva; Wennerström, Lovisa; Edman, Mari; Sandström, Annica

    2016-10-01

    Genetic diversity is needed for species' adaptation to changing selective pressures and is particularly important in regions with rapid environmental change such as the Baltic Sea. Conservation measures should consider maintaining large gene pools to maximize species' adaptive potential for long-term survival. In this study, we explored concerns regarding genetic variation in international and national policies that governs biodiversity and evaluated if and how such policy is put into practice in management plans governing Baltic Sea Marine Protected Areas (MPAs) in Sweden, Finland, Estonia, and Germany. We performed qualitative and quantitative textual analysis of 240 documents and found that agreed international and national policies on genetic biodiversity are not reflected in management plans for Baltic Sea MPAs. Management plans in all countries are largely void of goals and strategies for genetic biodiversity, which can partly be explained by a general lack of conservation genetics in policies directed toward aquatic environments.

  9. Pressure standards and sensors up to 3 GPa, actual state and development trends

    NASA Astrophysics Data System (ADS)

    Wisniewski, Roland; Molinar, Gianfranco

    1999-04-01

    Metrological problems connected with pressure standards and sensors up to 3 GPa as an introduction to the pressure measurements in the so-called “GIGAPASCAL REGION”, 1-100 GPa, are discussed. Re-examination of Bi I-Bi II phase transition pressure as a fixed point of the International Practical Pressure Scale and correction of the NaCl Pressure Scale is proposed. Well-established sensors as candidates for secondary pressure standards up to 3 GPa are briefly presented.

  10. Intracanal molar barometric pressure differentials at simulated altitude conditions - proof of concept study.

    PubMed

    Roberts, H W; Kirkpatrick, T C

    2016-08-01

    To evaluate whether objective data could be obtained regarding internal pressure conditions of a molar tooth with canals prepared but not filled exposed to reduced barometric pressures that could be experienced by aircrew. The root canals of five mandibular molars were prepared but not filled. Root apices were sealed with a resin-modified glass-ionomer liner and root surfaces sealed with a dental adhesive. The sealed root surfaces were then coated with a polyvinylsiloxane (PVS) adhesive and the teeth inserted into cylinders of PVS impression material to the level of the cervical enamel junction. Barometric pressure transducers were placed in the pulp chambers with the endodontic access sealed with cotton and a provisional restoration. The specimens were then subjected to a manually controlled, atmospheric altitude challenge consisting of a slow ascent and descent to a simulated 25 000 feet above sea level followed by a rapid altitude climb and descent. The real-time difference between intracanal and simulated atmospheric pressures were recorded and correlated (Pearson's, P = 0.05). No tooth material fractured, and there was no failure of the provisional restorations. Barometric pressures inside the closed prepared molar canals and the ambient atmospheric pressure were found to correlate (r(2)  = 0.97-0.99; P < 0.0001), but pressure equalization lags were observed. However, no differences greater than six pounds per square inch (310 torr) were noted. This pilot study established a protocol that demonstrated that objective data regarding barometric pressures within the prepared canals of molars can be obtained at simulated altitude conditions. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  11. Simultaneous in vivo comparison of water-filled and air-filled pressure measurement catheters: Implications for good urodynamic practice.

    PubMed

    Gammie, A; Abrams, P; Bevan, W; Ellis-Jones, J; Gray, J; Hassine, A; Williams, J; Hashim, H

    2016-11-01

    This study aimed to evaluate whether the pressure readings obtained from air-filled catheters (AFCs) are the same as the readings from simultaneously inserted water-filled catheters (WFCs). It also aimed to make any possible recommendations for the use of AFCs to conform to International Continence Society (ICS) Good Urodynamic Practices (GUP). Female patients undergoing urodynamic studies in a single center had water-filled and air-filled catheters simultaneously measuring abdominal and intravesical pressure during filling with saline and during voiding. The pressures recorded by each system at each event during the test were compared using paired t-test and Bland-Altman analyses. 62 patients were recruited, of whom 51 had pressures that could be compared during filling, and 23 during voiding. On average, the pressures measured by the two systems were not significantly different during filling and at maximum flow, but the values for a given patient were found to differ by up to 10 cmH 2 O. This study shows that AFCs and WFCs cannot be assumed to register equal values of pressure. It has further shown that even when the p det readings are compared with their value at the start of a test, a divergence of values of up to 10 cmH 2 O remains. If AFCs are used, care must be taken to compensate for any p det variations that occur during patient movement. Before AFCs are adopted, new normal values for resting pressures need to be developed to allow good quality AFC pressure readings to be made. Neurourol. Urodynam. 35:926-933, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. A Cabin Air Separator for EVA Oxygen

    NASA Technical Reports Server (NTRS)

    Graf, John C.

    2011-01-01

    Presently, the Extra-Vehicular Activities (EVAs) conducted from the Quest Joint Airlock on the International Space Station use high pressure, high purity oxygen that is delivered to the Space Station by the Space Shuttle. When the Space Shuttle retires, a new method of delivering high pressure, high purity oxygen to the High Pressure Gas Tanks (HPGTs) is needed. One method is to use a cabin air separator to sweep oxygen from the cabin air, generate a low pressure/high purity oxygen stream, and compress the oxygen with a multistage mechanical compressor. A main advantage to this type of system is that the existing low pressure oxygen supply infrastructure can be used as the source of cabin oxygen. ISS has two water electrolysis systems that deliver low pressure oxygen to the cabin, as well as chlorate candles and compressed gas tanks on cargo vehicles. Each of these systems can feed low pressure oxygen into the cabin, and any low pressure oxygen source can be used as an on-board source of oxygen. Three different oxygen separator systems were evaluated, and a two stage Pressure Swing Adsorption system was selected for reasons of technical maturity. Two different compressor designs were subjected to long term testing, and the compressor with better life performance and more favorable oxygen safety characteristics was selected. These technologies have been used as the basis of a design for a flight system located in Equipment Lock, and taken to Preliminary Design Review level of maturity. This paper describes the Cabin Air Separator for EVA Oxygen (CASEO) concept, describes the separator and compressor technology trades, highlights key technology risks, and describes the flight hardware concept as presented at Preliminary Design Review (PDR)

  13. Retinal arteriolar remodeling evaluated with adaptive optics camera: Relationship with blood pressure levels.

    PubMed

    Gallo, A; Mattina, A; Rosenbaum, D; Koch, E; Paques, M; Girerd, X

    2016-06-01

    To research a retinal arterioles wall-to-lumen ratio or lumen diameter cut-off that would discriminate hypertensive from normal subjects using adaptive optics camera. One thousand and five hundred subjects were consecutively recruited and Adaptive Optics Camera rtx1™ (Imagine-Eyes, Orsay, France) was used to measure wall thickness, internal diameter, to calculate wall-to-lumen ratio (WLR) and wall cross-sectional area of retinal arterioles. Sitting office blood pressure was measured once, just before retinal measurements and office blood pressure was defined as systolic blood pressure>=140mmHg and diastolic blood pressure>=90mmHg. ROC curves were constructed to determine cut-off values for retinal parameters to diagnose office hypertension. In another population of 276 subjects office BP, retinal arterioles evaluation and home blood pressure monitoring were obtained. The applicability of retinal WLR or diameter cut-off values were compared in patients with controlled, masked, white-coat and sustained hypertension. In 1500 patients, a WLR>0.31 discriminated office hypertensive subjects with a 0.57 sensitivity and 0.71 specificity. Lumen diameter<78.2μm discriminated office hypertension with a 0.73 sensitivity and a 0.52 specificity. In the other 276 patients, WLR was higher in sustained hypertension vs normotensive patients (0.330±0.06 vs 0.292±0.05; P<0.001) and diameter was narrower in masked hypertensive vs normotensive subjects (73.0±11.2 vs 78.5±11.6μm; P<0.005). A WLR higher than 0.31 is in favour of office arterial hypertension; a diameter under<78μm may indicate a masked hypertension. Retinal arterioles analysis through adaptive optics camera may help the diagnosis of arterial hypertension, in particular in case of masked hypertension. Copyright © 2016. Published by Elsevier SAS.

  14. Pressure Switch Is a Low Cost Battery Indicator

    NASA Technical Reports Server (NTRS)

    Abita, J. L.

    1982-01-01

    Conventional pressure switch, fabricated by printed-circuit manufacturing techniques, can indicate when charge on battery departs from preset level. Membrane on switch is exposed to internal pressure of battery, which varies according to stored charge. When pressure varies from preset level, switch can turn on a light-emitting diode or similar indicator to warn user that battery is low.

  15. 14 CFR 29.653 - Pressure venting and drainage of rotor blades.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pressure venting and drainage of rotor... § 29.653 Pressure venting and drainage of rotor blades. (a) For each rotor blade— (1) There must be means for venting the internal pressure of the blade; (2) Drainage holes must be provided for the blade...

  16. 14 CFR 27.653 - Pressure venting and drainage of rotor blades.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pressure venting and drainage of rotor....653 Pressure venting and drainage of rotor blades. (a) For each rotor blade— (1) There must be means for venting the internal pressure of the blade; (2) Drainage holes must be provided for the blade; and...

  17. 78 FR 63130 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... the low-pressure oxygen hoses with non-conductive low-pressure oxygen hoses in the stowage box and... internal, anti-collapse spring of the low-pressure oxygen hose, which can cause the low- pressure oxygen hose to melt or burn and lead to an oxygen-fed fire on the flight deck. DATES: We must receive comments...

  18. 78 FR 55679 - High Pressure Steel Cylinders From the People's Republic of China; Rescission of the 2011-2013...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-11

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-977] High Pressure Steel... antidumping duty order on high pressure steel cylinders from the People's Republic of China (``PRC'') for the... order on high pressure steel cylinders from the PRC.\\1\\ In response, on July 1, 2013, Beijing Tianhai...

  19. SGS Modeling of the Internal Energy Equation in LES of Supersonic Channel Flow

    NASA Astrophysics Data System (ADS)

    Raghunath, Sriram; Brereton, Giles

    2011-11-01

    DNS of fully-developed turbulent supersonic channel flows (Reτ = 190) at up to Mach 3 indicate that the turbulent heat fluxes depend only weakly on Mach number, while the viscous dissipation and pressure dilatation do so strongly. Moreover, pressure dilatation makes a significant contribution to the internal energy budget at Mach 3 and higher. The balance between these terms is critical to determining the temperature (and so molecular viscosity) from the internal energy equation and so, in LES of these flows, it is essential to use accurate SGS models for the viscous dissipation and the pressure dilatation. In this talk, we present LES results for supersonic channel flow, using SGS models for these terms that are based on the resolved-scale dilatation, an inverse timescale, and SGS momentum fluxes, which intrinsically represent this Mach number effect.

  20. Expanding hollow metal rings

    DOEpatents

    Peacock, Harold B [Evans, GA; Imrich, Kenneth J [Grovetown, GA

    2009-03-17

    A sealing device that may expand more planar dimensions due to internal thermal expansion of a filler material. The sealing material is of a composition such that when desired environment temperatures and internal actuating pressures are reached, the sealing materials undergoes a permanent deformation. For metallic compounds, this permanent deformation occurs when the material enters the plastic deformation phase. Polymers, and other materials, may be using a sealing mechanism depending on the temperatures and corrosivity of the use. Internal pressures are generated by either rapid thermal expansion or material phase change and may include either liquid or solid to gas phase change, or in the gaseous state with significant pressure generation in accordance with the gas laws. Sealing material thickness and material composition may be used to selectively control geometric expansion of the seal such that expansion is limited to a specific facing and or geometric plane.

  1. IAEA international studies on irradiation embrittlement of reactor pressure vessel steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brumovsky, M.; Steele, L.E.

    1997-02-01

    In last 25 years, three phases a Co-operative Research Programme on Irradiation Embrittlement of Reactor Pressure Vessel Steels has been organized by the International Atomic Energy Agency. This programme started with eight countries in 1971 and finally 16 countries took part in phase III of the Programme in 1983. Several main efforts were put into preparation of the programme, but the principal task was concentrated on an international comparison of radiation damage characterization by different laboratories for steels of {open_quotes}old{close_quotes} (with high impurity contents) and {open_quotes}advanced{close_quotes} (with low impurity contents) types as well as on development of small scale fracturemore » mechanics procedures applicable to reactor pressure vessel surveillance programmes. This year, a new programme has been opened, concentrated mostly on small scale fracture mechanics testing.« less

  2. The Influence of Running on Foot Posture and In-Shoe Plantar Pressures.

    PubMed

    Bravo-Aguilar, María; Gijón-Noguerón, Gabriel; Luque-Suarez, Alejandro; Abian-Vicen, Javier

    2016-03-01

    Running can be considered a high-impact practice, and most people practicing continuous running experience lower-limb injuries. The aim of this study was to determine the influence of 45 min of running on foot posture and plantar pressures. The sample comprised 116 healthy adults (92 men and 24 women) with no foot-related injuries. The mean ± SD age of the participants was 28.31 ± 6.01 years; body mass index, 23.45 ± 1.96; and training time, 11.02 ± 4.22 h/wk. Outcome measures were collected before and after 45 min of running at an average speed of 12 km/h, and included the Foot Posture Index (FPI) and a baropodometric analysis. The results show that foot posture can be modified after 45 min of running. The mean ± SD FPI changed from 6.15 ± 2.61 to 4.86 ± 2.65 (P < .001). Significant decreases in mean plantar pressures in the external, internal, rearfoot, and forefoot edges were found after 45 min of running. Peak plantar pressures in the forefoot decreased after running. The pressure-time integral decreased during the heel strike phase in the internal edge of the foot. In addition, a decrease was found in the pressure-time integral during the heel-off phase in the internal and rearfoot edges. The findings suggest that after 45 min of running, a pronated foot tends to change into a more neutral position, and decreased plantar pressures were found after the run.

  3. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol

    PubMed Central

    Topouchian, Jirar; Agnoletti, Davide; Blacher¹, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland

    2014-01-01

    Background Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. Methods The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. Results All four tested devices passed the validation process. The mean differences between the device and mercury readings were: −1.8±5.1 mmHg and −0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and −1.2±4.3 mmHg for the Omron HEM-7420 device; −0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Conclusion Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly. PMID:24476688

  4. High Temperature Electrolysis Pressurized Experiment Design, Operation, and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.E. O'Brien; X. Zhang; G.K. Housley

    2012-09-01

    A new facility has been developed at the Idaho National Laboratory for pressurized testing of solid oxide electrolysis stacks. Pressurized operation is envisioned for large-scale hydrogen production plants, yielding higher overall efficiencies when the hydrogen product is to be delivered at elevated pressure for tank storage or pipelines. Pressurized operation also supports higher mass flow rates of the process gases with smaller components. The test stand can accommodate planar cells with dimensions up to 8.5 cm x 8.5 cm and stacks of up to 25 cells. It is also suitable for testing other cell and stack geometries including tubular cells.more » The pressure boundary for these tests is a water-cooled spool-piece pressure vessel designed for operation up to 5 MPa. Pressurized operation of a ten-cell internally manifolded solid oxide electrolysis stack has been successfully demonstrated up 1.5 MPa. The stack is internally manifolded and operates in cross-flow with an inverted-U flow pattern. Feed-throughs for gas inlets/outlets, power, and instrumentation are all located in the bottom flange. The entire spool piece, with the exception of the bottom flange, can be lifted to allow access to the internal furnace and test fixture. Lifting is accomplished with a motorized threaded drive mechanism attached to a rigid structural frame. Stack mechanical compression is accomplished using springs that are located inside of the pressure boundary, but outside of the hot zone. Initial stack heatup and performance characterization occurs at ambient pressure followed by lowering and sealing of the pressure vessel and subsequent pressurization. Pressure equalization between the anode and cathode sides of the cells and the stack surroundings is ensured by combining all of the process gases downstream of the stack. Steady pressure is maintained by means of a backpressure regulator and a digital pressure controller. A full description of the pressurized test apparatus is provided in this report. Results of initial testing showed the expected increase in open-cell voltage associated with elevated pressure. However, stack performance in terms of area-specific resistance was enhanced at elevated pressure due to better gas diffusion through the porous electrodes of the cells. Some issues such as cracked cells and seals were encountered during testing. Full resolution of these issues will require additional testing to identify the optimum test configurations and protocols.« less

  5. A physicochemical investigation of membrane fouling in cold microfiltration of skim milk.

    PubMed

    Tan, T J; Wang, D; Moraru, C I

    2014-01-01

    The main challenge in microfiltration (MF) is membrane fouling, which leads to a significant decline in permeate flux and a change in membrane selectivity over time. This work aims to elucidate the mechanisms of membrane fouling in cold MF of skim milk by identifying and quantifying the proteins and minerals involved in external and internal membrane fouling. Microfiltration was conducted using a 1.4-μm ceramic membrane, at a temperature of 6±1°C, cross-flow velocity of 6m/s, and transmembrane pressure of 159kPa, for 90min. Internal and external foulants were extracted from a ceramic membrane both after a brief contact between the membrane and skim milk, to evaluate instantaneous adsorption of foulants, and after MF. Four foulant streams were collected: weakly attached external foulants, weakly attached internal foulants, strongly attached external foulants, and strongly attached internal foulants. Liquid chromatography coupled with tandem mass spectrometry analysis showed that all major milk proteins were present in all foulant streams. Proteins did appear to be the major cause of membrane fouling. Proteomics analysis of the foulants indicated elevated levels of serum proteins as compared with milk in the foulant fractions collected from the adsorption study. Caseins were preferentially introduced into the fouling layer during MF, when transmembrane pressure was applied, as confirmed both by proteomics and mineral analyses. The knowledge generated in this study advances the understanding of fouling mechanisms in cold MF of skim milk and can be used to identify solutions for minimizing membrane fouling and increasing the efficiency of milk MF. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Traction-assisted Internal Negative Pressure Wound Therapy With Bridging Retention Sutures to Facilitate Staged Closure of High-risk Wounds Under Tension.

    PubMed

    DeFazio, Michael V; Economides, James M; Anghel, Ersilia L; Mathis, Ryan K; Barbour, John R; Attinger, Christopher E

    2017-10-01

    Loss of domain often complicates attempts at delayed wound closure in regions of high tension. Wound temporization with traction-assisted internal negative pressure wound therapy (NPWT), using bridging retention sutures, can minimize the effects of edema and elastic recoil that contribute to progressive tissue retraction over time. The investigators evaluated the safety and efficacy of this technique for complex wound closure. Between May 2015 and November 2015, 18 consecutive patients underwent staged reconstruction of complex and/or contaminated soft tissue defects utilizing either conventional NPWT or modified NPWT with instillation and continuous dermatotraction via bridging retention sutures. Instillation of antimicrobial solution was reserved for wounds containing infected/exposed hardware or prosthetic devices. Demographic data, wound characteristics, reconstructive outcomes, and complications were reviewed retrospectively. Eighteen wounds were treated with traction-assisted internal NPWT using the conventional (n = 11) or modified instillation (n = 7) technique. Defects involved the lower extremity (n = 14), trunk (n = 3), and proximal upper extremity (n = 1), with positive cultures identified in 12 wounds (67%). Therapy continued for 3 to 8 days (mean, 4.3 days), resulting in an average wound surface area reduction of 78% (149 cm² vs. 33 cm²) at definitive closure. Seventeen wounds (94%) were closed directly, whereas the remaining defect required coverage with a local muscle flap and skin graft. At final follow-up (mean, 12 months), 89% of wounds remained closed. In 2 patients with delayed, recurrent periprosthetic infection (mean, 7.5 weeks), serial debridement/hardware removal mandated free tissue transfer for composite defect reconstruction. Traction-assisted internal NPWT provides a safe and effective alternative to reduce wound burden and facilitate definitive closure in cases where delayed reconstruction of high-tension wounds is planned.

  7. Validation of the Omron M6 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients.

    PubMed

    Altunkan, Sekip; Iliman, Nevzat; Altunkan, Erkan

    2008-04-01

    Despite the widespread use of automated self-measurement monitors, there is limited published evidence on their accuracy and reliability on different patient groups. The objective of this study was to evaluate the accuracy and reliability of the Omron M6 (HEM-7001-E) upper-arm blood pressure (BP) device against mercury sphygmomanometer on elderly patients according to the criteria of the International Protocol. Thirty-three patients above 65 years of age, who were classified based on the BP categories of the International Protocol, were recruited for the study. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. During the validation study, 99 measurements were obtained from 33 patients for comparison. The first phase was carried out on 15 patients and if the device passed this phase, 18 more patients were selected. Mean discrepancies and standard deviations of the device sphygmomanometer were 1.4+/-5.3 mmHg for systolic BP (SBP) and -1.4+/-4.5 mmHg for diastolic BP (DBP) in the study group. The device passed phase 1 in 15 patients. In phase 2.1, from the total 99 comparisons, 76, 92, and 97 for SBP and 77, 94, and 99 for DBP were less than 5, 10, and 15 mmHg, respectively. The Omron M6 passed phases 2.1 and 2.2 in the elderly group of patients. The Omron M6 (HEM-7001-E) upper-arm BP monitor passed according to the International Protocol criteria and can be recommended for use in elderly patients.

  8. Testing of a Stitched Composite Large-Scale Multi-Bay Pressure Box

    NASA Technical Reports Server (NTRS)

    Jegley, Dawn; Rouse, Marshall; Przekop, Adam; Lovejoy, Andrew

    2016-01-01

    NASA has created the Environmentally Responsible Aviation (ERA) Project to develop technologies to reduce aviation's impact on the environment. A critical aspect of this pursuit is the development of a lighter, more robust airframe to enable the introduction of unconventional aircraft configurations. NASA and The Boeing Company have worked together to develop a structural concept that is lightweight and an advancement beyond state-of-the-art composite structures. The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) is an integrally stiffened panel design where elements are stitched together. The PRSEUS concept is designed to maintain residual load carrying capabilities under a variety of damage scenarios. A series of building block tests were evaluated to explore the fundamental assumptions related to the capability and advantages of PRSEUS panels. The final step in the building block series is an 80%-scale pressure box representing a portion of the center section of a Hybrid Wing Body (HWB) transport aircraft. The testing of this article under maneuver load and internal pressure load conditions is the subject of this paper. The experimental evaluation of this article, along with the other building block tests and the accompanying analyses, has demonstrated the viability of a PRSEUS center body for the HWB vehicle. Additionally, much of the development effort is also applicable to traditional tube-and-wing aircraft, advanced aircraft configurations, and other structures where weight and through-the-thickness strength are design considerations.

  9. An inflatable ergonomic 3-chamber fundal pressure belt to assist vaginal delivery.

    PubMed

    Acanfora, Luisa; Rampon, Michela; Filippeschi, Marco; Marchi, Marco; Montisci, Massimo; Viel, Guido; Cosmi, Erich

    2013-01-01

    To evaluate whether Baby-guard-a new medical device with an ergonomic 3-chamber inflatable abdominal belt-can reduce complications associated with vaginal delivery. A randomized controlled single-blind prospective study of 80 pregnant women delivering at term was conducted at San Giuseppe Hospital, Empoli, Italy. In the study group (n=40), the abdominal belt was inflated to optimal therapeutic pressures. In the control group (n=40), the abdominal belt was inflated to minimal, non-therapeutic pressures. Factors relating to maternal, fetal, and labor complications during vaginal delivery were evaluated. Compared with the control group, women in the study group experienced a lower incidence of perineal and cervical lacerations (P<0.001); reduced use of the Kristeller maneuver (P<0.001); shorter duration of the second stage of labor (P<0.001); less psychologic and physical fatigue (P<0.001); fewer maternal requests for cesarean delivery during labor (P<0.001); fewer vacuum extractions (P<0.01); and fewer cesarean deliveries (P<0.02). No neonatal intensive care unit admissions were recorded in the study group versus 7 in the control group (P<0.012). Use of the ergonomic 3-chamber inflatable abdominal belt system reduced the incidence of risks associated with vaginal labor. Clinical trials.gov identifier: NCT01566331. Copyright © 2012 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Space exercise and Earth benefits.

    PubMed

    Macias, Brandon R; Groppo, Eli R; Eastlack, Robert K; Watenpaugh, Donald E; Lee, Stuart M C; Schneider, Suzanne M; Boda, Wanda L; Smith, Scott M; Cutuk, Adnan; Pedowitz, Robert A; Meyer, R Scott; Hargens, Alan R

    2005-08-01

    The detrimental impact of long duration space flight on physiological systems necessitates the development of exercise countermeasures to protect work capabilities in gravity fields of Earth, Moon and Mars. The respective rates of physiological deconditioning for different organ systems during space flight has been described as a result of data collected during and after missions on the Space Shuttle, International Space Station, Mir, and bed rest studies on Earth. An integrated countermeasure that simulates the body's hydrostatic pressure gradient, provides mechanical stress to the bones and muscles, and stimulates the neurovestibular system may be critical for maintaining health and well being of crew during long-duration space travel, such as a mission to Mars. Here we review the results of our studies to date of an integrated exercise countermeasure for space flight, lower body negative pressure (LBNP) treadmill exercise, and potential benefits of its application to athletic training on Earth. Additionally, we review the benefits of Lower Body Positive Pressure (LBPP) exercise for rehabilitation of postoperative patients. Presented first are preliminary data from a 30-day bed rest study evaluating the efficacy of LBNP exercise as an integrated exercise countermeasure for the deconditioning effects of microgravity. Next, we review upright LBNP exercise as a training modality for athletes by evaluating effects on the cardiovascular system and gait mechanics. Finally, LBPP exercise as a rehabilitation device is examined with reference to gait mechanics and safety in two groups of postoperative patients.

  11. Pressure Venting Tests of Phenolic Impregnated Carbon Ablator (PICA)

    NASA Technical Reports Server (NTRS)

    Blosser, Max L.; Knutson, Jeffrey R.

    2015-01-01

    A series of tests was devised to investigate the pressure venting behavior of one of the candidate ablators for the Orion capsule heat shield. Three different specimens of phenolic impregnated carbon ablator (PICA) were instrumented with internal pressure taps and subjected to rapid pressure changes from near vacuum to one atmosphere and simulated Orion ascent pressure histories. The specimens vented rapidly to ambient pressure and sustained no detectable damage during testing. Peak pressure differences through the thickness of a 3-inch-thick specimen were less than 1 psi during a simulated ascent pressure history.

  12. Effects of temperature and pressure on thermodynamic properties of Cd0.50 Zn0.50 Se alloy

    NASA Astrophysics Data System (ADS)

    Aarifeen, Najm ul; Afaq, A.

    2017-09-01

    Thermodynamic properties of \\text{C}{{\\text{d}}0.50} \\text{Z}{{\\text{n}}0.50} Se alloy are studied using quasi harmonic model for pressure range 0-10 GPa and temperature range 0-1000 K. The structural optimization is obtained by self consistent field calculations and full-potential linear muffin-tin orbital method with GGA+U as an exchange correlation functional where U=2.3427 eV is the hubbard potential. The effects of temperature and pressure on the bulk modulus, Helmholtz free energy, internal energy, entropy, Debye temperature, Grüneisen parameter, thermal expansion coefficient and heat capacities of the material are observed and discussed. The bulk modulus, Helmholtz free energy and Debye temperature are found to decrease with increasing temperature while there is an increasing behavior when the pressure rises. Whereas internal energy has increasing trend with rises in temperature and it almost remains insensitive to pressure. The entropy of the system increases (decreases) with a rise of pressure (temperature).

  13. Plasma pressure distribution in the equatorial plane of the Earth's magnetosphere at geocentric distances of 6-10 R E according to the international THEMIS mission data

    NASA Astrophysics Data System (ADS)

    Kirpichev, I. P.; Antonova, E. E.

    2011-08-01

    The structure of the averaged plasma pressure distribution in the plasma ring around the Earth at geocentric distances of ˜6-10 R E has been determined. The distribution function moments measured on the international THEMIS mission satellites have been used. The plasma pressure distribution in the equatorial plane at 15 R E > XSM > -15 R E and 15 R E > YSM > -15 R E has been statistically studied. The radial dependence of the plasma pressure at the day-night and morning-evening meridians has been analyzed. It has been indicated that the plasma ring around the Earth has a structure, which is close to being azimuthally symmetric. The achieved results have been compared with the pressure distributions obtained previously. It has been indicated that in the overlapping regions, the achieved results agree with the previously obtained data within the pressure determination errors.

  14. Buckling of Cracked Laminated Composite Cylindrical Shells Subjected to Combined Loading

    NASA Astrophysics Data System (ADS)

    Allahbakhsh, Hamidreza; Shariati, Mahmoud

    2013-10-01

    A series of finite element analysis on the cracked composite cylindrical shells under combined loading is carried out to study the effect of loading condition, crack size and orientation on the buckling behavior of laminated composite cylindrical shells. The interaction buckling curves of cracked laminated composite cylinders subject to different combinations of axial compression, bending, internal pressure and external pressure are obtained, using the finite element method. Results show that the internal pressure increases the critical buckling load of the CFRP cylindrical shells and bending and external pressure decrease it. Numerical analysis show that axial crack has the most detrimental effect on the buckling load of a cylindrical shell and results show that for lower values of the axial compressive load and higher values of the external pressure, the buckling is usually in the global mode and for higher values of axial compressive load and lower levels of external pressure the buckling mode is mostly in the local mode.

  15. Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller.

    PubMed

    Kleinheyer, Matthias; Timms, Daniel L; Tansley, Geoffrey D; Nestler, Frank; Greatrex, Nicholas A; Frazier, O Howard; Cohn, William E

    2016-09-01

    Unlike the earlier reciprocating volume displacement-type pumps, rotary blood pumps (RBPs) typically operate at a constant rotational speed and produce continuous outflow. When RBP technology is used in constructing a total artificial heart (TAH), the pressure waveform that the TAH produces is flat, without the rise and fall associated with a normal arterial pulse. Several studies have suggested that pulseless circulation may impair microcirculatory perfusion and the autoregulatory response and may contribute to adverse events such as gastrointestinal bleeding, arteriovenous malformations, and pump thrombosis. It may therefore be beneficial to attempt to reproduce pulsatile output, similar to that generated by the native heart, by rapidly modulating the speed of an RBP impeller. The choice of an appropriate speed profile and control strategy to generate physiologic waveforms while minimizing power consumption and blood trauma becomes a challenge. In this study, pump operation modes with six different speed profiles using the BiVACOR TAH were evaluated in vitro. These modes were compared with respect to: hemodynamic pulsatility, which was quantified as surplus hemodynamic energy (SHE); maximum rate of change of pressure (dP/dt); pulse power index; and motor power consumption as a function of pulse pressure. The results showed that the evaluated variables underwent different trends in response to changes in the speed profile shape. The findings indicated a possible trade-off between SHE levels and flow rate pulsatility related to the relative systolic duration in the speed profile. Furthermore, none of the evaluated measures was sufficient to fully characterize hemodynamic pulsatility. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Nondestructive Evaluation Approaches Developed for Material Characterization in Aeronautics and Space Applications

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Kautz, Harold E.; Gyekenyesi, Andrew L.; Abdul-Aziz, Ali; Martin, Richard E.

    2001-01-01

    At the NASA Glenn Research Center, nondestructive evaluation (NDE) approaches were developed or tailored for characterizing advanced material systems. The emphasis was on high-temperature aerospace propulsion applications. The material systems included monolithic ceramics, superalloys, and high-temperature composites. In the aeronautics area, the major applications were cooled ceramic plate structures for turbine applications, gamma-TiAl blade materials for low-pressure turbines, thermoelastic stress analysis for residual stress measurements in titanium-based and nickel-based engine materials, and acousto-ultrasonics for creep damage assessment in nickel-based alloys. In the space area, applications consisted of cooled carbon-carbon composites for gas generator combustors and flywheel rotors composed of carbon-fiber-reinforced polymer matrix composites for energy storage on the International Space Station.

  17. Internal-Performance Evaluation of Two Fixed-Divergent-Shroud Ejectors

    NASA Technical Reports Server (NTRS)

    Mihaloew, James R.

    1960-01-01

    Ejectors designed for use in a Mach 2.2 aircraft were evaluated over a range of representative primary pressure ratios and ejector corrected weight-flow ratios. Basic thrust and pumping characteristics are discussed in terms of an assumed engine operating schedule to illustrate the variation of performance with Mach number. The two designs differed about 16 percent in the shroud longitudinal spacing ratio. For corrected ejector weight-flow ratios up to 0.10, the performance of the fixed-shroud ejector designs is comparable with that of a similar continuously variable ejector except at conditions corresponding to acceleration with afterburning from Mach 0.4 to 1.2. In this region, the ejector thrust ratio decreased to a minimum of 0.96.

  18. Electrochemically Induced Nanobubbles between Graphene and Mica.

    PubMed

    Dollekamp, Edwin; Bampoulis, Pantelis; Poelsema, Bene; Zandvliet, Harold J W; Kooij, E Stefan

    2016-07-05

    We present a new method to create dynamic nanobubbles. The nanobubbles are created between graphene and mica by reducing intercalated water to hydrogen. The nanobubbles have a typical radius of several hundred nanometers, a height of a few tens of nanometers and an internal pressure in the range of 0.5-8 MPa. Our approach paves the way to the realization of nanobubbles of which both size and internal pressure are tunable.

  19. The HoMedics BPA-200 and BPA-300 home blood pressure devices fail the European Society of Hypertension International Protocol and cannot be recommended for patient use.

    PubMed

    Grim, Clarence E; Grim, Carlene M

    2008-08-01

    We have tested two home blood pressure monitors made by the HoMedics, Inc., 300 Pontiac Trail, Commerce Township, Michigan 48390, USA, using the European Society of Hypertension International Protocol. Both failed and we believe it is important to get this into the literature quickly to protect patients and practitioners.

  20. Creep-rupture tests of internally pressurized Inconel 702 tubes

    NASA Technical Reports Server (NTRS)

    Gumto, K. H.

    1973-01-01

    Seamless Inconel 702 tubes with 0.375-in. outside diameter and 0.025-in. wall thickness were tested to failure at temperatures from 1390 to 1575 F and internal helium pressures from 700 to 1800 psi. Lifetimes ranged from 29 to 1561 hr. The creep-rupture strength of the tubes was about 70 percent lower than that of sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

  1. KENNEDY SPACE CENTER, FLA. - Lisa Malone, deputy director of External Relations and Business Development at KSC, emcees a ceremony in the Space Station Processing Facility to highlight the arrival of two major components of the International Space Station. NASA's Node 2, built by the European Space Agency (ESA) in Italy arrived at KSC on June 1. It will be the next pressurized module installed on the Station. The pressurized module of the Japanese Experiment Module (JEM), named "Kibo" (Hope) arrived at KSC on June 4. It is Japan's primary contribution to the Station. The ceremony held today included the official transfer of ownership signing of Node 2 between the ESA and NASA.. Speakers at the ceremony included KSC Director Roy Bridges Jr.; NASA's Michael C. Kostelnik, deputy associate administrator for International Space Station and Shuttle Programs, and William Gerstenmaier, International Space Station Program manager; Alan Thirkettle, International Space Station Program manager for Node 2, ESA; Andrea Lorenzoni, International Space Station Program manager for Node 2, Italian Space Agency; Kuniaki Shiraki, JEM Project manager, National Aerospace and Development Agency of Japan.

    NASA Image and Video Library

    2003-06-18

    KENNEDY SPACE CENTER, FLA. - Lisa Malone, deputy director of External Relations and Business Development at KSC, emcees a ceremony in the Space Station Processing Facility to highlight the arrival of two major components of the International Space Station. NASA's Node 2, built by the European Space Agency (ESA) in Italy arrived at KSC on June 1. It will be the next pressurized module installed on the Station. The pressurized module of the Japanese Experiment Module (JEM), named "Kibo" (Hope) arrived at KSC on June 4. It is Japan's primary contribution to the Station. The ceremony held today included the official transfer of ownership signing of Node 2 between the ESA and NASA.. Speakers at the ceremony included KSC Director Roy Bridges Jr.; NASA's Michael C. Kostelnik, deputy associate administrator for International Space Station and Shuttle Programs, and William Gerstenmaier, International Space Station Program manager; Alan Thirkettle, International Space Station Program manager for Node 2, ESA; Andrea Lorenzoni, International Space Station Program manager for Node 2, Italian Space Agency; Kuniaki Shiraki, JEM Project manager, National Aerospace and Development Agency of Japan.

  2. KENNEDY SPACE CENTER, FLA. - Andrea Lorenzoni, International Space Station Program manager for Node 2, Italian Space Agency; Alan Thirkettle, International Space Station Program manager for Node 2, European Space Agency (ESA); and NASA’s Michael C. Kostelnik, deputy associate administrator for International Space Station and Shuttle Programs, sign documents officially transferring ownership of Node 2 between the ESA and NASA. The signing was part of a ceremony highlighting the arrival of two major components of the International Space Station. NASA's Node 2, built by the European Space Agency (ESA) in Italy, arrived at KSC on June 1. It will be the next pressurized module installed on the Station. The pressurized module (above right) of the Japanese Experiment Module (JEM), named "Kibo" (Hope), arrived at KSC on June 4. It is Japan's primary contribution to the Station. Emceed by Lisa Malone (far left), deputy director of External Relations and Business Development at KSC, the ceremony also included these speakers: Center Director Roy Bridges Jr.; NASA’s William Gerstenmaier, International Space Station Program manager; and Kuniaki Shiraki, JEM Project manager, National Aerospace and Development Agency of Japan.

    NASA Image and Video Library

    2003-06-18

    KENNEDY SPACE CENTER, FLA. - Andrea Lorenzoni, International Space Station Program manager for Node 2, Italian Space Agency; Alan Thirkettle, International Space Station Program manager for Node 2, European Space Agency (ESA); and NASA’s Michael C. Kostelnik, deputy associate administrator for International Space Station and Shuttle Programs, sign documents officially transferring ownership of Node 2 between the ESA and NASA. The signing was part of a ceremony highlighting the arrival of two major components of the International Space Station. NASA's Node 2, built by the European Space Agency (ESA) in Italy, arrived at KSC on June 1. It will be the next pressurized module installed on the Station. The pressurized module (above right) of the Japanese Experiment Module (JEM), named "Kibo" (Hope), arrived at KSC on June 4. It is Japan's primary contribution to the Station. Emceed by Lisa Malone (far left), deputy director of External Relations and Business Development at KSC, the ceremony also included these speakers: Center Director Roy Bridges Jr.; NASA’s William Gerstenmaier, International Space Station Program manager; and Kuniaki Shiraki, JEM Project manager, National Aerospace and Development Agency of Japan.

  3. KENNEDY SPACE CENTER, FLA. - Alan Thirkettle (center), International Space Station Program manager for Node 2, European Space Agency (ESA); and NASA’s Michael C. Kostelnik (right), deputy associate administrator for International Space Station and Shuttle Programs, sign documents officially transferring ownership of Node 2 between the ESA and NASA. At left, also part of the signing, is Andrea Lorenzoni (left), International Space Station Program manager for Node 2, Italian Space Agency. NASA's Node 2, built by ESA in Italy, arrived at KSC on June 1. It will be the next pressurized module installed on the Station. The pressurized module of the Japanese Experiment Module (JEM), named "Kibo" (Hope), arrived at KSC on June 4. It is Japan's primary contribution to the Station. Emceed by Lisa Malone, deputy director of External Relations and Business Development at KSC, the ceremony also included these speakers: Center Director Roy Bridges Jr.; NASA’s William Gerstenmaier, International Space Station Program manager; and Kuniaki Shiraki, JEM Project manager, National Aerospace and Development Agency of Japan.

    NASA Image and Video Library

    2003-06-18

    KENNEDY SPACE CENTER, FLA. - Alan Thirkettle (center), International Space Station Program manager for Node 2, European Space Agency (ESA); and NASA’s Michael C. Kostelnik (right), deputy associate administrator for International Space Station and Shuttle Programs, sign documents officially transferring ownership of Node 2 between the ESA and NASA. At left, also part of the signing, is Andrea Lorenzoni (left), International Space Station Program manager for Node 2, Italian Space Agency. NASA's Node 2, built by ESA in Italy, arrived at KSC on June 1. It will be the next pressurized module installed on the Station. The pressurized module of the Japanese Experiment Module (JEM), named "Kibo" (Hope), arrived at KSC on June 4. It is Japan's primary contribution to the Station. Emceed by Lisa Malone, deputy director of External Relations and Business Development at KSC, the ceremony also included these speakers: Center Director Roy Bridges Jr.; NASA’s William Gerstenmaier, International Space Station Program manager; and Kuniaki Shiraki, JEM Project manager, National Aerospace and Development Agency of Japan.

  4. Novel burn device for rapid, reproducible burn wound generation.

    PubMed

    Kim, J Y; Dunham, D M; Supp, D M; Sen, C K; Powell, H M

    2016-03-01

    Scarring following full thickness burns leads to significant reductions in range of motion and quality of life for burn patients. To effectively study scar development and the efficacy of anti-scarring treatments in a large animal model (female red Duroc pigs), reproducible, uniform, full-thickness, burn wounds are needed to reduce variability in observed results that occur with burn depth. Prior studies have proposed that initial temperature of the burner, contact time with skin, thermal capacity of burner material, and the amount of pressure applied to the skin need to be strictly controlled to ensure reproducibility. The purpose of this study was to develop a new burner that enables temperature and pressure to be digitally controlled and monitored in real-time throughout burn wound creation and compare it to a standard burn device. A custom burn device was manufactured with an electrically heated burn stylus and a temperature control feedback loop via an electronic microstat. Pressure monitoring was controlled by incorporation of a digital scale into the device, which measured downward force. The standard device was comprised of a heat resistant handle with a long rod connected to the burn stylus, which was heated using a hot plate. To quantify skin surface temperature and internal stylus temperature as a function of contact time, the burners were heated to the target temperature (200±5°C) and pressed into the skin for 40s to create the thermal injuries. Time to reach target temperature and elapsed time between burns were recorded. In addition, each unit was evaluated for reproducibility within and across three independent users by generating burn wounds at contact times spanning from 5 to 40s at a constant pressure and at pressures of 1 or 3lbs with a constant contact time of 40s. Biopsies were collected for histological analysis and burn depth quantification using digital image analysis (ImageJ). The custom burn device maintained both its internal temperature and the skin surface temperature near target temperature throughout contact time. In contrast, the standard burner required more than 20s of contact time to raise the skin surface temperature to target due to its quickly decreasing internal temperature. The custom burner was able to create four consecutive burns in less than half the time of the standard burner. Average burn depth scaled positively with time and pressure in both burn units. However, the distribution of burn depth within each time-pressure combination in the custom device was significantly smaller than with the standard device and independent of user. The custom burn device's ability to continually heat the burn stylus and actively control pressure and temperature allowed for more rapid and reproducible burn wounds. Burns of tailored and repeatable depths, independent of user, provide a platform for the study of anti-scar and other wound healing therapies without the added variable of non-uniform starting injury. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  5. Novel burn device for rapid, reproducible burn wound generation

    PubMed Central

    Kim, J.Y.; Dunham, D.M.; Supp, D.M.; Sen, C.K.; Powell, H.M.

    2016-01-01

    Introduction Scarring following full thickness burns leads to significant reductions in range of motion and quality of life for burn patients. To effectively study scar development and the efficacy of anti-scarring treatments in a large animal model (female red Duroc pigs), reproducible, uniform, full-thickness, burn wounds are needed to reduce variability in observed results that occur with burn depth. Prior studies have proposed that initial temperature of the burner, contact time with skin, thermal capacity of burner material, and the amount of pressure applied to the skin need to be strictly controlled to ensure reproducibility. The purpose of this study was to develop a new burner that enables temperature and pressure to be digitally controlled and monitored in real-time throughout burn wound creation and compare it to a standard burn device. Methods A custom burn device was manufactured with an electrically heated burn stylus and a temperature control feedback loop via an electronic microstat. Pressure monitoring was controlled by incorporation of a digital scale into the device, which measured downward force. The standard device was comprised of a heat resistant handle with a long rod connected to the burn stylus, which was heated using a hot plate. To quantify skin surface temperature and internal stylus temperature as a function of contact time, the burners were heated to the target temperature (200 ± 5 °C) and pressed into the skin for 40 s to create the thermal injuries. Time to reach target temperature and elapsed time between burns were recorded. In addition, each unit was evaluated for reproducibility within and across three independent users by generating burn wounds at contact times spanning from 5 to 40 s at a constant pressure and at pressures of 1 or 3 lbs with a constant contact time of 40 s. Biopsies were collected for histological analysis and burn depth quantification using digital image analysis (ImageJ). Results The custom burn device maintained both its internal temperature and the skin surface temperature near target temperature throughout contact time. In contrast, the standard burner required more than 20 s of contact time to raise the skin surface temperature to target due to its quickly decreasing internal temperature. The custom burner was able to create four consecutive burns in less than half the time of the standard burner. Average burn depth scaled positively with time and pressure in both burn units. However, the distribution of burn depth within each time-pressure combination in the custom device was significantly smaller than with the standard device and independent of user. Conclusions The custom burn device's ability to continually heat the burn stylus and actively control pressure and temperature allowed for more rapid and reproducible burn wounds. Burns of tailored and repeatable depths, independent of user, provide a platform for the study of anti-scar and other wound healing therapies without the added variable of non-uniform starting injury. PMID:26803369

  6. Static internal performance of convergent single-expansion-ramp nozzles with various combinations of internal geometric parameters

    NASA Technical Reports Server (NTRS)

    Bare, E. Ann; Capone, Francis J.

    1989-01-01

    An investigation was conducted in the Static Test Facility of the Langley 16-Foot Transonic Tunnel to determine the effects of five geometric design parameters on the internal performance of convergent single expansion ramp nozzles. The effects of ramp chordal angle, initial ramp angle, flap angle, flap length, and ramp length were determined. All nozzles tested has a nominally constant throat area and aspect ratio. Static pressure distributions along the centerlines of the ramp and flap were also obtained for each configuration. Nozzle pressure ratio was varied up to 10.0 for all configurations.

  7. Providing Pressurized Gasses to the International Space Station (ISS): Developing a Composite Overwrapped Pressure Vessel (COPV) for the Safe Transport of Oxygen and Nitrogen

    NASA Technical Reports Server (NTRS)

    Kezirian, Michael; Cook, Anthony; Dick, Brandon; Phoenix, S. Leigh

    2012-01-01

    To supply oxygen and nitrogen to the International Space Station, a COPV tank is being developed to meet requirements beyond that which have been flown. In order to "Ship Full' and support compatibility with a range of launch site operations, the vessel was designed for certification to International Standards (ISO) that have a different approach than current NASA certification approaches. These requirements were in addition to existing NASA certification standards had to be met. Initial risk-reduction development tests have been successful. Qualification is in progress.

  8. Evaluation of 1.0 mm i.d. column performances on ultra high pressure liquid chromatography instrumentation.

    PubMed

    Lestremau, François; Wu, Di; Szücs, Roman

    2010-07-23

    The present study focuses on the evaluation of 1.0 mm i.d. (internal diameter) columns on a commercial Ultra-High Pressure system. These systems have been developed specifically to operate columns with small volumes, typically 2.1 mm i.d., by reducing extra-column volume dispersion. The use of columns with smaller i.d. results in a reduced solvent consumption and required sample volume. The evaluation of the columns was carried out with samples containing neutral and pharmaceutical compounds. In isocratic mode, the extra-column volume produced additional band broadening leading to poor performances compared to equivalent 2.1 mm i.d. columns. By increasing the length of the column, the influence of the extra-column bandspreading could be reduced and 75,000 plates were obtained when four columns were coupled. In gradient mode, the effect of the extra-column contribution on efficiency was limited and about 80% of the performance of the 2.1 mm i.d. columns was obtained. Optimum conditions in gradient mode were further investigated by changing flow rate, gradient time and column length. A different approach of the calculation of peak capacity was also considered for the comparison of the influence of these different parameters. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  9. Evaluation of Hypertension Prevention and Control Programs in Lima, Peru.

    PubMed

    Chung, Bonhee; Kim, Dohyeong; Nam, Eun Woo

    2018-01-01

    The Korea International Cooperation Agency (KOICA) established 4 health centers to provide hypertension screening and a health support program in a deprived urban area of Lima, Peru. This case report provides a mid-term evaluation of the KOICA's hypertension prevention and control programs. A follow up study was performed on 663 residents who were diagnosed with prehypertension or hypertension (Stage 1 and 2) in the 4 KOICA health centers. Patients participated in programs designed to prevent and control hypertension through education sessions over the course of 6 months. Using simple descriptive statistics and computer simulations, we evaluated the effect of hypertension prevention and control programs on the participants. The KOICA health programs appeared to significantly contribute to lowering the blood pressure (BP) of the participants. The total number of participants with normal BP increased from none to 109. Overall, the female and younger patients responded better to the KOICA programs than the male and older participants. In addition, the average systolic BP, diastolic BP, and body mass index of all participants was significantly reduced. The KOICA programs were effective at lowering blood pressure, particularly amongst the prehypertension group than the Stage 1 and 2 hypertension groups. This suggests that providing an extensive screening service for adults with prehypertension will help control hypertension in the early stages.

  10. Risk Associated with Pulse Pressure on Out-of-Office Blood Pressure Measurement

    PubMed Central

    Gu, Yu-Mei; Aparicio, Lucas S.; Liu, Yan-Ping; Asayama, Kei; Hansen, Tine W.; Niiranen, Teemu J.; Boggia, José; Thijs, Lutgarde; Staessen, Jan A.

    2014-01-01

    Background Longitudinal studies have demonstrated that the risk of cardiovascular disease increases with pulse pressure (PP). However, PP remains an elusive cardiovascular risk factor with findings being inconsistent between studies. The 2013 ESH/ESC guideline proposed that PP is useful in stratification and suggested a threshold of 60 mm Hg, which is 10 mm Hg higher compared to that in the 2007 guideline; however, no justification for this increase was provided. Methodology Published thresholds of PP are based on office blood pressure measurement and often on arbitrary categorical analyses. In the International Database on Ambulatory blood pressure in relation to Cardiovascular Outcomes (IDACO) and the International Database on HOme blood pressure in relation to Cardiovascular Outcome (IDHOCO), we determined outcome-driven thresholds for PP based on ambulatory or home blood pressure measurement, respectively. Results The main findings were that for people aged <60 years, PP did not refine risk stratification, whereas in older people the thresholds were 64 and 76 mm Hg for the ambulatory and home PP, respectively. However, PP provided little added predictive value over and beyond classical risk factors. PMID:26587443

  11. How Brazil outpaced the United States when it came to AIDS: the politics of civic infiltration, reputation, and strategic internationalization.

    PubMed

    Gómez, Eduardo J

    2011-04-01

    Using a temporal approach dividing the reform process into two periods, this article explains how both Brazil and the United States were slow to respond to AIDS. However, Brazil eventually outpaced the United States in its response due to international rather than democratic pressures. Since the early 1990s, Brazil's success has been attributed to "strategic internationalization": the concomitant acceptance and rejection of global pressure for institutional change and antiretroviral treatment, respectively. The formation of tripartite partnerships among donors, AIDS officials, and nongovernmental organizations has allowed Brazil to avoid foreign aid dependency, while generating ongoing incentives for influential AIDS officials to incessantly pressure Congress for additional funding. Given the heightened international media attention, concern about Brazil's reputation has contributed to a high level of political commitment. By contrast, the United States' more isolationist relationship with the international community, its focus on leading the global financing of AIDS efforts, and the absence of tripartite partnerships have prevented political leaders from adequately responding to the ongoing urban AIDS crisis. Thus, Brazil shows that strategically working with the international health community for domestic rather than international influence is vital for a sustained and effective response to AIDS.

  12. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  13. Coupled BE/FE/BE approach for scattering from fluid-filled structures

    NASA Technical Reports Server (NTRS)

    Everstine, Gordon C.; Cheng, Raymond S.

    1990-01-01

    NASHUA is a coupled finite element/boundary element capability built around NASTRAN for calculating the low frequency far-field acoustic pressure field radiated or scattered by an arbitrary, submerged, three-dimensional, elastic structure subjected to either internal time-harmonic mechanical loads or external time-harmonic incident loadings. Described here are the formulation and use of NASHUA for solving such structural acoustics problems when the structure is fluid-filled. NASTRAN is used to generate the structural finite element model and to perform most of the required matrix operations. Both fluid domains are modeled using the boundary element capability in NASHUA, whose matrix formulation (and the associated NASTRAN DMAP) for evacuated structures can be used with suitable interpretation of the matrix definitions. After computing surface pressures and normal velocities, far-field pressures are evaluated using an asymptotic form of the Helmholtz exterior integral equation. The proposed numerical approach is validated by comparing the acoustic field scattered from a submerged fluid-filled spherical thin shell to that obtained with a series solution, which is also derived here.

  14. Repair of Kaplan turbine shaft sealing based on evaluation of hydraulic conditions

    NASA Astrophysics Data System (ADS)

    Lakatos, K.; Szamosi, Z.; Bereczkei, S.

    2012-11-01

    This paper has been written to call attention to a potential danger what may occur in Kaplan turbine refurbishments. In Tiszalök hydropower plant, Hungary, the shaft sealing of the refurbished turbine was damaged. In searching for the reasons it was assumed that due to increased internal velocities in the turbine, the pressure at the hub clearance became lower than the atmospheric pressure, and therefore the sealing, which always operated satisfactorily before the refurbishment, had uncertain water supply, dry-running occurred, and after some time the sealing was burnt. First the flow conditions in the turbine and the pressure at the hub clearance were calculated by a one-dimensional flow model. Later this was refined by a two-dimensional approach. The above conclusion was also justified by the data acquisition system and by observing the operation of the small dewatering pump. When the turbine operated at a larger discharge than a certain limit value, then the dewatering pump remained standstill, indicating that no water passed through the shaft sealing. External water supply was then applied, and after this the turbine operated all right.

  15. 78 FR 31574 - Welded Stainless Steel Pressure Pipe From Malaysia, Thailand, and Vietnam; Institution of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-1210-1212 (Preliminary)] Welded Stainless Steel Pressure Pipe From Malaysia, Thailand, and Vietnam; Institution of Antidumping Duty..., by reason of imports from Malaysia, Thailand, and Vietnam of welded stainless steel pressure pipe...

  16. Predictive equations for respiratory muscle strength according to international and Brazilian guidelines.

    PubMed

    Pessoa, Isabela M B S; Houri Neto, Miguel; Montemezzo, Dayane; Silva, Luisa A M; Andrade, Armèle Dornelas De; Parreira, Verônica F

    2014-01-01

    The maximum static respiratory pressures, namely the maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP), reflect the strength of the respiratory muscles. These measures are simple, non-invasive, and have established diagnostic and prognostic value. This study is the first to examine the maximum respiratory pressures within the Brazilian population according to the recommendations proposed by the American Thoracic Society and European Respiratory Society (ATS/ERS) and the Brazilian Thoracic Association (SBPT). To establish reference equations, mean values, and lower limits of normality for MIP and MEP for each age group and sex, as recommended by the ATS/ERS and SBPT. We recruited 134 Brazilians living in Belo Horizonte, MG, Brazil, aged 20-89 years, with a normal pulmonary function test and a body mass index within the normal range. We used a digital manometer that operationalized the variable maximum average pressure (MIP/MEP). At least five tests were performed for both MIP and MEP to take into account a possible learning effect. We evaluated 74 women and 60 men. The equations were as follows: MIP=63.27-0.55 (age)+17.96 (gender)+0.58 (weight), r(2) of 34% and MEP= - 61.41+2.29 (age) - 0.03(age(2))+33.72 (gender)+1.40 (waist), r(2) of 49%. In clinical practice, these equations could be used to calculate the predicted values of MIP and MEP for the Brazilian population.

  17. Preliminary results from a subsonic high angle-of-attack flush airdata sensing (HI-FADS) system: Design, calibration, and flight test evaluation

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Moes, Timothy R.; Larson, Terry J.

    1990-01-01

    A nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was installed and flight-tested on the F-18 high alpha research flight vehicle. The system is a matrix of 25 pressure orifices in concentric circles on the nose of the vehicle. The orifices determine angles of attack and sideslip, Mach number, and pressure altitude. Pressure was transmitted from the orifices to an electronically scanned pressure module by lines of pneumatic tubing. The HI-FADS system was calibrated and demonstrated using dutch roll flight maneuvers covering large Mach, angle-of-attack, and sideslip ranges. Reference airdata for system calibration were generated by a minimum variance estimation technique blending measurements from two wingtip airdata booms with inertial velocities, aircraft angular rates and attitudes, precision radar tracking, and meteorological analyses. The pressure orifice calibration was based on identifying empirical adjustments to modified Newtonian flow on a hemisphere. Calibration results are presented. Flight test results used all 25 orifices or used a subset of 9 orifices. Under moderate maneuvering conditions, the HI-FADS system gave excellent results over the entire subsonic Mach number range up to 55 deg angle of attack. The internal pneumatic frequency response of the system is accurate to beyond 10 Hz. Aerodynamic lags in the aircraft flow field caused some performance degradation during heavy maneuvering.

  18. Contribution of energetic and heavy ions to the plasma pressure: The 27 September to 3 October 2002 storm

    NASA Astrophysics Data System (ADS)

    Kronberg, E. A.; Welling, D.; Kistler, L. M.; Mouikis, C.; Daly, P. W.; Grigorenko, E. E.; Klecker, B.; Dandouras, I.

    2017-09-01

    Magnetospheric plasma sheet ions drift toward the Earth and populate the ring current. The ring current plasma pressure distorts the terrestrial internal magnetic field at the surface, and this disturbance strongly affects the strength of a magnetic storm. The contribution of energetic ions (>40 keV) and of heavy ions to the total plasma pressure in the near-Earth plasma sheet is not always considered. In this study, we evaluate the contribution of low-energy and energetic ions of different species to the total plasma pressure for the storm observed by the Cluster mission from 27 September until 3 October 2002. We show that the contribution of energetic ions (>40 keV) and of heavy ions to the total plasma pressure is ≃76-98.6% in the ring current and ≃14-59% in the magnetotail. The main source of oxygen ions, responsible for ≃56% of the plasma pressure of the ring current, is located at distances earthward of XGSE ≃ -13.5 RE during the main phase of the storm. The contribution of the ring current particles agrees with the observed Dst index. We model the magnetic storm using the Space Weather Modeling Framework (SWMF). We assess the plasma pressure output in the ring current for two different ion outflow models in the SWMF through comparison with observations. Both models yield reasonable results. The model which produces the most heavy ions agrees best with the observations. However, the data suggest that there is still potential for refinement in the simulations.

  19. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. An evaluation of factors influencing pore pressure in accretionary complexes: Implications for taper angle and wedge mechanics

    USGS Publications Warehouse

    Saffer, D.M.; Bekins, B.A.

    2006-01-01

    At many subduction zones, accretionary complexes form as sediment is off-scraped from the subducting plate. Mechanical models that treat accretionary complexes as critically tapered wedges of sediment demonstrate that pore pressure controls their taper angle by modifying basal and internal shear strength. Here, we combine a numerical model of groundwater flow with critical taper theory to quantify the effects of sediment and de??collement permeability, sediment thickness, sediment partitioning between accretion and underthrusting, and plate convergence rate on steady state pore pressure. Our results show that pore pressure in accretionary wedges can be viewed as a dynamically maintained response to factors which drive pore pressure (source terms) and those that limit flow (permeability and drainage path length). We find that sediment permeability and incoming sediment thickness are the most important factors, whereas fault permeability and the partitioning of sediment have a small effect. For our base case model scenario, as sediment permeability is increased, pore pressure decreases from near-lithostatic to hydrostatic values and allows stable taper angles to increase from ??? 2.5?? to 8??-12.5??. With increased sediment thickness in our models (from 100 to 8000 m), increased pore pressure drives a decrease in stable taper angle from 8.4??-12.5?? to 15?? to <4??) with increased sediment thickness (from <1 to 7 km). One key implication is that hydrologic properties may strongly influence the strength of the crust in a wide range of geologic settings. Copyright 2006 by the American Geophysical Union.

Top