Sample records for internal standard correction

  1. A drift correction optimization technique for the reduction of the inter-measurement dispersion of isotope ratios measured using a multi-collector plasma mass spectrometer

    NASA Astrophysics Data System (ADS)

    Doherty, W.; Lightfoot, P. C.; Ames, D. E.

    2014-08-01

    The effects of polynomial interpolation and internal standardization drift corrections on the inter-measurement dispersion (statistical) of isotope ratios measured with a multi-collector plasma mass spectrometer were investigated using the (analyte, internal standard) isotope systems of (Ni, Cu), (Cu, Ni), (Zn, Cu), (Zn, Ga), (Sm, Eu), (Hf, Re) and (Pb, Tl). The performance of five different correction factors was compared using a (statistical) range based merit function ωm which measures the accuracy and inter-measurement range of the instrument calibration. The frequency distribution of optimal correction factors over two hundred data sets uniformly favored three particular correction factors while the remaining two correction factors accounted for a small but still significant contribution to the reduction of the inter-measurement dispersion. Application of the merit function is demonstrated using the detection of Cu and Ni isotopic fractionation in laboratory and geologic-scale chemical reactor systems. Solvent extraction (diphenylthiocarbazone (Cu, Pb) and dimethylglyoxime (Ni) was used to either isotopically fractionate the metal during extraction using the method of competition or to isolate the Cu and Ni from the sample (sulfides and associated silicates). In the best case, differences in isotopic composition of ± 3 in the fifth significant figure could be routinely and reliably detected for Cu65/63 and Ni61/62. One of the internal standardization drift correction factors uses a least squares estimator to obtain a linear functional relationship between the measured analyte and internal standard isotope ratios. Graphical analysis demonstrates that the points on these graphs are defined by highly non-linear parametric curves and not two linearly correlated quantities which is the usual interpretation of these graphs. The success of this particular internal standardization correction factor was found in some cases to be due to a fortuitous, scale dependent, parametric curve effect.

  2. Correction for isotopic interferences between analyte and internal standard in quantitative mass spectrometry by a nonlinear calibration function.

    PubMed

    Rule, Geoffrey S; Clark, Zlatuse D; Yue, Bingfang; Rockwood, Alan L

    2013-04-16

    Stable isotope-labeled internal standards are of great utility in providing accurate quantitation in mass spectrometry (MS). An implicit assumption has been that there is no "cross talk" between signals of the internal standard and the target analyte. In some cases, however, naturally occurring isotopes of the analyte do contribute to the signal of the internal standard. This phenomenon becomes more pronounced for isotopically rich compounds, such as those containing sulfur, chlorine, or bromine, higher molecular weight compounds, and those at high analyte/internal standard concentration ratio. This can create nonlinear calibration behavior that may bias quantitative results. Here, we propose the use of a nonlinear but more accurate fitting of data for these situations that incorporates one or two constants determined experimentally for each analyte/internal standard combination and an adjustable calibration parameter. This fitting provides more accurate quantitation in MS-based assays where contributions from analyte to stable labeled internal standard signal exist. It can also correct for the reverse situation where an analyte is present in the internal standard as an impurity. The practical utility of this approach is described, and by using experimental data, the approach is compared to alternative fits.

  3. 78 FR 14457 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Parts 60 and 63 [EPA-HQ-OAR-2008-0708, FRL-9756-4] RIN 2060-AQ58 National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines Correction In rule...

  4. Standard addition with internal standardisation as an alternative to using stable isotope labelled internal standards to correct for matrix effects-Comparison and validation using liquid chromatography-​tandem mass spectrometric assay of vitamin D.

    PubMed

    Hewavitharana, Amitha K; Abu Kassim, Nur Sofiah; Shaw, Paul Nicholas

    2018-06-08

    With mass spectrometric detection in liquid chromatography, co-eluting impurities affect the analyte response due to ion suppression/enhancement. Internal standard calibration method, using co-eluting stable isotope labelled analogue of each analyte as the internal standard, is the most appropriate technique available to correct for these matrix effects. However, this technique is not without drawbacks, proved to be expensive because separate internal standard for each analyte is required, and the labelled compounds are expensive or require synthesising. Traditionally, standard addition method has been used to overcome the matrix effects in atomic spectroscopy and was a well-established method. This paper proposes the same for mass spectrometric detection, and demonstrates that the results are comparable to those with the internal standard method using labelled analogues, for vitamin D assay. As conventional standard addition procedure does not address procedural errors, we propose the inclusion of an additional internal standard (not co-eluting). Recoveries determined on human serum samples show that the proposed method of standard addition yields more accurate results than the internal standardisation using stable isotope labelled analogues. The precision of the proposed method of standard addition is superior to the conventional standard addition method. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Fluorescein thiocarbamyl amino acids as internal standards for migration time correction in capillary sieving electrophoresis

    PubMed Central

    Pugsley, Haley R.; Swearingen, Kristian E.; Dovichi, Norman J.

    2009-01-01

    A number of algorithms have been developed to correct for migration time drift in capillary electrophoresis. Those algorithms require identification of common components in each run. However, not all components may be present or resolved in separations of complex samples, which can confound attempts for alignment. This paper reports the use of fluorescein thiocarbamyl derivatives of amino acids as internal standards for alignment of 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ)-labeled proteins in capillary sieving electrophoresis. The fluorescein thiocarbamyl derivative of aspartic acid migrates before FQ-labeled proteins and the fluorescein thiocarbamyl derivative of arginine migrates after the FQ-labeled proteins. These compounds were used as internal standards to correct for variations in migration time over a two-week period in the separation of a cellular homogenate. The experimental conditions were deliberately manipulated by varying electric field and sample preparation conditions. Three components of the homogenate were used to evaluate the alignment efficiency. Before alignment, the average relative standard deviation in migration time for these components was 13.3%. After alignment, the average relative standard deviation in migration time for these components was reduced to 0.5%. PMID:19249052

  6. 76 FR 49650 - Regulations Governing Practice Before the Internal Revenue Service; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    ... governing of practice before the IRS and the standards with respect to tax returns. DATES: This correction... Part 10 Accountants, Administrative practice and procedure, Lawyers, Reporting and recordkeeping requirements, Taxes. Correction of Publication Accordingly, 31 CFR part 10 is corrected by making the following...

  7. Gold internal standard correction for elemental imaging of soft tissue sections by LA-ICP-MS: element distribution in eye microstructures.

    PubMed

    Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; González, Héctor; Alvarez, Lydia; Coca-Prados, Miguel; Sanz-Medel, Alfredo

    2013-04-01

    Laser ablation coupled to inductively coupled plasma mass spectrometry has been developed for the elemental imaging of Mg, Fe and Cu distribution in histological tissue sections of fixed eyes, embedded in paraffin, from human donors (cadavers). This work presents the development of a novel internal standard correction methodology based on the deposition of a homogeneous thin gold film on the tissue surface and the use of the (197)Au(+) signal as internal standard. Sample preparation (tissue section thickness) and laser conditions were carefully optimized, and internal normalisation using (197)Au(+) was compared with (13)C(+) correction for imaging applications. (24)Mg(+), (56)Fe(+) and (63)Cu(+) distributions were investigated in histological sections of the anterior segment of the eye (including the iris, ciliary body, cornea and trabecular meshwork) and were shown to be heterogeneously distributed along those tissue structures. Reproducibility was assessed by imaging different human eye sections from the same donor and from ten different eyes from adult normal donors, which showed that similar spatial maps were obtained and therefore demonstrate the analytical potential of using (197)Au(+) as internal standard. The proposed analytical approach could offer a robust tool with great practical interest for clinical studies, e.g. to investigate trace element distribution of metals and their alterations in ocular diseases.

  8. Results in a consecutive series of 83 surgical corrections of symptomatic stenotic kinking of the internal carotid artery.

    PubMed

    Illuminati, Giulio; Ricco, Jean-Baptiste; Caliò, Francesco G; D'Urso, Antonio; Ceccanei, Gianluca; Vietri, Francesco

    2008-01-01

    Although there is a growing body of evidence to document the safety and efficacy of operative treatment of carotid stenosis, surgical indications for elongation and kinking of the internal carotid artery remain controversial. The goal of this study was to evaluate the efficacy of surgical correction of internal carotid artery kinking in patients with persistent hemispheric symptoms despite antiplatelet therapy. A consecutive series of 81 patients (mean age, 64 years) underwent 83 surgical procedures to correct kinking of the internal carotid artery either by shortening and reimplanting the vessel on the common carotid artery, inserting a bypass graft, or transposing the vessel onto the external carotid artery. Mean follow-up was 56 months (range, 15-135 months). Study endpoints were 30-day mortality and any stroke occurring during follow-up. No postoperative death was observed. The postoperative stroke rate was 1%. Primary patency, freedom from neurologic symptoms, and late survival at 5 years (x +/- standard deviation) were 89 +/- 4.1%, 92 +/- 4%, and 71 +/- 6%, respectively. The findings of this study indicate that surgical correction for symptomatic stenotic kinking of the internal carotid artery is safe and effective in relieving symptoms and preventing stroke. Operative correction should be considered as the standard treatment for patients with symptomatic carotid kinking that does not respond to antiplatelet therapy.

  9. 78 FR 8431 - Hazardous Materials: Harmonization with International Standards (RRR)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-06

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 172 [Docket Nos. PHMSA-2012-0027 (HM-215L)] RIN 2137-AE87 Hazardous Materials: Harmonization with International Standards (RRR) Correction In rule document 2012-31243 appearing on pages 988 through 1100 in the...

  10. 76 FR 70062 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 46 CFR Parts 160, 180, and 199 [Docket No. USCG-2010-0048] RIN 1625-AB46 Lifesaving Equipment: Production Testing and Harmonization With International Standards Correction In rule document 2011-25035, appearing on pages 62962-63015 in the issue of Monday...

  11. Correction of the data generated by mass spectrometry analyses of biological tissues: application to food authentication.

    PubMed

    Engel, Erwan; Ratel, Jérémy

    2007-06-22

    The objective of the work was to assess the relevance for the authentication of food of a novel chemometric method developed to correct mass spectrometry (MS) data from instrumental drifts, namely, the comprehensive combinatory standard correction (CCSC). Applied to gas chromatography (GC)-MS data, the method consists in analyzing a liquid sample with a mixture of n internal standards and in using the best combination of standards to correct the MS signal provided by each compound. The paper focuses on the authentication of the type of feeding in farm animals based on the composition in volatile constituents of their adipose tissues. The first step of the work enabled on one hand to ensure the feasibility of the conversion of the adipose tissue sample into a liquid phase required for the use of the CCSC method and on the other hand, to determine the key parameters of the extraction of the volatile fraction from this liquid phase by dynamic headspace. The second step showed the relevance of the CCSC pre-processing of the MS fingerprints generated by dynamic headspace-MS analysis of lamb tissues, for the discrimination of animals fed exclusively with pasture (n=8) or concentrate (n=8). When compared with filtering of raw data, internal normalization and correction by a single standard, the CCSC method increased by 17.1-, 3.3- and 1.3-fold, respectively, the number of mass fragments which discriminated the type of feeding. The final step confirmed the advantage of the CCSC pre-processing of dynamic headspace-gas chromatography-MS data for revealing molecular tracers of the type of feeding those number (n=72) was greater when compared to the number of tracers obtained with raw data (n=42), internal normalization (n=63) and correction by a single standard (n=57). The relevance of the information gained by using the CCSC method is discussed.

  12. Comprehensive combinatory standard correction: a calibration method for handling instrumental drifts of gas chromatography-mass spectrometry systems.

    PubMed

    Deport, Coralie; Ratel, Jérémy; Berdagué, Jean-Louis; Engel, Erwan

    2006-05-26

    The current work describes a new method, the comprehensive combinatory standard correction (CCSC), for the correction of instrumental signal drifts in GC-MS systems. The method consists in analyzing together with the products of interest a mixture of n selected internal standards, and in normalizing the peak area of each analyte by the sum of standard areas and then, select among the summation operator sigma(p = 1)(n)C(n)p possible sums, the sum that enables the best product discrimination. The CCSC method was compared with classical techniques of data pre-processing like internal normalization (IN) or single standard correction (SSC) on their ability to correct raw data from the main drifts occurring in a dynamic headspace-gas chromatography-mass spectrometry system. Three edible oils with closely similar compositions in volatile compounds were analysed using a device which performance was modulated by using new or used dynamic headspace traps and GC-columns, and by modifying the tuning of the mass spectrometer. According to one-way ANOVA, the CCSC method increased the number of analytes discriminating the products (31 after CCSC versus 25 with raw data or after IN and 26 after SSC). Moreover, CCSC enabled a satisfactory discrimination of the products irrespective of the drifts. In a factorial discriminant analysis, 100% of the samples (n = 121) were well-classified after CCSC versus 45% for raw data, 90 and 93%, respectively after IN and SSC.

  13. Prison Health Care Governance: Guaranteeing Clinical Independence

    PubMed Central

    Pont, Jörg; Enggist, Stefan; Stöver, Heino; Williams, Brie; Greifinger, Robert

    2018-01-01

    Clinical independence is an essential component of good health care and health care professionalism, particularly in correctional settings (jails, prisons, and other places of detention), where the relationship between patients and caregivers is not based on free choice and where the punitive correctional setting can challenge optimal medical care. Independence for the delivery of health care services is defined by international standards as a critical element for quality health care in correctional settings, yet many correctional facilities do not meet these standards because of a lack of awareness, persisting legal regulations, contradictory terms of employment for health professionals, or current health care governance structures. We present recommendations for the implementation of independent health care in correctional settings. PMID:29470125

  14. Bromine isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry with a conventional sample introduction system.

    PubMed

    de Gois, Jefferson S; Vallelonga, Paul; Spolaor, Andrea; Devulder, Veerle; Borges, Daniel L G; Vanhaecke, Frank

    2016-01-01

    A simple and accurate methodology for Br isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) with pneumatic nebulization for sample introduction was developed. The Br(+) signals could be measured interference-free at high mass resolution. Memory effects for Br were counteracted using 5 mmol L(-1) of NH4OH in sample, standard, and wash solutions. The major cation load of seawater was removed via cation exchange chromatography using Dowex 50WX8 resin. Subsequent Br preconcentration was accomplished via evaporation of the sample solution at 90 °C, which did not induce Br losses or isotope fractionation. Mass discrimination was corrected for by external correction using a Cl-matched standard measured in a sample-standard bracketing approach, although Sr, Ge, and Se were also tested as potential internal standards for internal correction for mass discrimination. The δ(81)Br (versus standard mean ocean bromide (SMOB)) values thus obtained for the NaBr isotopic reference material NIST SRM 977 and for IRMM BCR-403 seawater certified reference material are in agreement with literature values. For NIST SRM 977, the (81)Br/(79)Br ratio (0.97291) was determined with a precision ≤0.08‰ relative standard deviation (RSD).

  15. Internal standards in fluorescent X-ray spectroscopy1 1 Publication authorized by the Director, U.S. Geological Survey.

    USGS Publications Warehouse

    Adler, I.; Axelrod, J.M.

    1955-01-01

    The use of internal standards in the analysis of ores and minerals of widely-varying matrix by means of fluorescent X-ray spectroscopy is frequently the most practical approach. Internal standards correct for absorption and enhancement effects except when an absorption edge falls between the comparison lines or a very strong emission line falls between the absorption edges responsible for the comparison lines. Particle size variations may introduce substantial errors. One method of coping with the particle size problem is grinding the sample with an added abrasive. ?? 1955.

  16. Variance analysis refines overhead cost control.

    PubMed

    Cooper, J C; Suver, J D

    1992-02-01

    Many healthcare organizations may not fully realize the benefits of standard cost accounting techniques because they fail to routinely report volume variances in their internal reports. If overhead allocation is routinely reported on internal reports, managers can determine whether billing remains current or lost charges occur. Healthcare organizations' use of standard costing techniques can lead to more realistic performance measurements and information system improvements that alert management to losses from unrecovered overhead in time for corrective action.

  17. Naval Personnel Can Improve Compliance With the Berry Amendment and the Buy American Act

    DTIC Science & Technology

    2015-08-12

    Amendment. Introduction 2 │ DODIG-2015-161 • FSG 83—textiles, leather and furs,6 apparel , and shoes; • FSG 84— clothing , individual equipment and insignia...personnel amended standard operating procedures and internal processes to improve compliance with the Berry Amendment. NAWCAD-Lakehurst personnel...corrective action and amended standard operating procedures and internal processes to improve compliance with the Buy American Act. Additionally, NAWCAD

  18. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    PubMed Central

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  19. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

    PubMed

    Hanousek, Ondrej; Brunner, Marion; Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-11-14

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3-0.5% ( u c,rel ), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement u c,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%).

  20. Development of a direct procedure for the measurement of sulfur isotope variability in beers by MC-ICP-MS.

    PubMed

    Giner Martínez-Sierra, J; Santamaria-Fernandez, R; Hearn, R; Marchante Gayón, J M; García Alonso, J I

    2010-04-14

    In this work, a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) was evaluated for the direct measurement of sulfur stable isotope ratios in beers as a first step toward a general study of the natural isotope variability of sulfur in foods and beverages. Sample preparation consisted of a simple dilution of the beers with 1% (v/v) HNO(3). It was observed that different sulfur isotope ratios were obtained for different dilutions of the same sample indicating that matrix effects affected differently the transmission of the sulfur ions at masses 32, 33, and 34 in the mass spectrometer. Correction for mass bias related matrix effects was evaluated using silicon internal standardization. For that purpose, silicon isotopes at masses 29 and 30 were included in the sulfur cup configuration and the natural silicon content in beers used for internal mass bias correction. It was observed that matrix effects on differential ion transmission could be corrected adequately using silicon internal standardization. The natural isotope variability of sulfur has been evaluated by measuring 26 different beer brands. Measured delta(34)S values ranged from -0.2 to 13.8 per thousand. Typical combined standard uncertainties of the measured delta(34)S values were < or = 2 per thousand. The method has therefore great potential to study sulfur isotope variability in foods and beverages.

  1. An Evaluation of Unit and ½ Mass Correction Approaches as a ...

    EPA Pesticide Factsheets

    Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive on 66Zn. Currently, US EPA Method 200.8 does not address these as sources of false positives. Additionally, these M+2 false positives are typically enhanced if collision cell technology is utilized to reduce polyatomic interferences associated with ICP-MS detection. A preliminary evaluation indicates that instrumental tuning conditions can impact the observed M+2/M+1 ratio and in turn the false positives generated on Zn, As and Se. Both unit and ½ mass approaches will be evaluated to correct for these false positives relative to the benchmark concentrations estimates from a triple quadrupole ICP-MS using standard solutions. The impact of matrix on these M+2 corrections will be evaluated over multiple analysis days with a focus on evaluating internal standards that mirror the matrix induced shifts in the M+2 ion transmission. The goal of this evaluation is to move away from fixed M+2 corrective approaches and move towards sample specific approaches that mimic the sample matrix induced variability while attempting to address intra-day variability of the M+2 correction factors through the use of internal standards. Oral Presentation via webinar for EPA Laboratory Technical Informati

  2. [THE VERIFICATION OF ANALYTICAL CHARACTERISTICS OF THREE MODELS OF GLUCOMETERS].

    PubMed

    Timofeev, A V; Khaibulina, E T; Mamonov, R A; Gorst, K A

    2016-01-01

    The individual portable systems of control of glucose level in blood commonly known as glucometers permit to patients with diabetes mellitus to independently correct pharmaceutical therapy. The effectiveness of this correction depends on accuracy of control of glucose level. The evaluation was implemented concerning minimal admissible accuracy and clinical accuracy of control of glucose level of devices Contour TC, Satellite Express and One Touch Select according standards expounded in GOST 15197-2011 and international standard ISO 15197-2013. It is demonstrated that Contour TC and One Touch Select meet the requirements of these standards in part of accuracy while Satellite Express does not.

  3. Cracks in Continuing Education's Mirror and a Fix To Correct Its Distorted Internal and External Image.

    ERIC Educational Resources Information Center

    Loch, John R.

    2003-01-01

    Outlines problems in continuing higher education, suggesting that it lacks (1) a standard name; (2) a unified voice on national issues; (3) a standard set of roles and functions; (4) a standard title for the chief administrative officer; (5) an accreditation body and process; and (6) resolution of the centralization/decentralization issue. (SK)

  4. Utilization of a deuterated derivatization agent to synthesize internal standards for gas chromatography-tandem mass spectrometry quantification of silylated metabolites.

    PubMed

    Lien, Stina K; Kvitvang, Hans Fredrik Nyvold; Bruheim, Per

    2012-07-20

    GC-MS analysis of silylated metabolites is a sensitive method that covers important metabolite groups such as sugars, amino acids and non-amino organic acids, and it has become one of the most important analytical methods for exploring the metabolome. Absolute quantitative GC-MS analysis of silylated metabolites poses a challenge as different metabolites have different derivatization kinetics and as their silyl-derivates have varying stability. This report describes the development of a targeted GC-MS/MS method for quantification of metabolites. Internal standards for each individual metabolite were obtained by derivatization of a mixture of standards with deuterated N-methyl-N-trimethylsilyltrifluoroacetamide (d9-MSTFA), and spiking this solution into MSTFA derivatized samples prior to GC-MS/MS analysis. The derivatization and spiking protocol needed optimization to ensure that the behaviour of labelled compound responses in the spiked sample correctly reflected the behaviour of unlabelled compound responses. Using labelled and unlabelled MSTFA in this way enabled normalization of metabolite responses by the response of their deuterated counterpart (i.e. individual correction). Such individual correction of metabolite responses reproducibly resulted in significantly higher precision than traditional data correction strategies when tested on samples both with and without serum and urine matrices. The developed method is thus a valuable contribution to the field of absolute quantitative metabolomics. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. International comparison of activity measurements of a solution of 75Se

    NASA Astrophysics Data System (ADS)

    Ratel, Guy

    2002-04-01

    Activity measurements of a solution of 75Se, supplied by the BIPM, have been carried out by 21 laboratories within the framework of an international comparison. Seven different methods were used. Details on source preparation, experimental facilities and counting data are reported. The measured activity-concentration values show a total spread of 6.62% before correction and 6.02% after correction for delayed events, with standard deviations of the unweighted means of 0.45% and 0.36%, respectively. The correction for delayed events was measured directly by four laboratories. Unfortunately no consensus on the activity value could be deduced from their results. The results of the comparison have been entered in the tables of the International Reference System (SIR) for γ-ray emitting radionuclides. The half-life of the metastable state was also determined by two laboratories and found to be in good agreement with the values found in the literature.

  6. Correction of Stahl ear deformity using a suture technique.

    PubMed

    Khan, Muhammad Adil Abbas; Jose, Rajive M; Ali, Syed Nadir; Yap, Lok Huei

    2010-09-01

    Correction of partial ear deformities can be a challenging task for the plastic surgeon. There are no standard techniques for correcting many of these deformities, and several different techniques are described in literature. Stahl ear is one such anomaly, characterized by an accessory third crus in the ear cartilage, giving rise to an irregular helical rim. The conventional techniques of correcting this deformity include either excision of the cartilage, repositioning of the cartilage, or scoring techniques. We recently encountered a case of Stahl ear deformity and undertook correction using internal sutures with very good results. The technical details of the surgery are described along with a review of literature on correcting similar anomalies.

  7. Connecting dark matter annihilation to the vertex functions of Standard Model fermions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Jason; Light, Christopher, E-mail: jkumar@hawaii.edu, E-mail: lightc@hawaii.edu

    We consider scenarios in which dark matter is a Majorana fermion which couples to Standard Model fermions through the exchange of charged mediating particles. The matrix elements for various dark matter annihilation processes are then related to one-loop corrections to the fermion-photon vertex, where dark matter and the charged mediators run in the loop. In particular, in the limit where Standard Model fermion helicity mixing is suppressed, the cross section for dark matter annihilation to various final states is related to corrections to the Standard Model fermion charge form factor. These corrections can be extracted in a gauge-invariant manner frommore » collider cross sections. Although current measurements from colliders are not precise enough to provide useful constraints on dark matter annihilation, improved measurements at future experiments, such as the International Linear Collider, could improve these constraints by several orders of magnitude, allowing them to surpass the limits obtainable by direct observation.« less

  8. Infrared weak corrections to strongly interacting gauge boson scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ciafaloni, Paolo; Urbano, Alfredo

    2010-04-15

    We evaluate the impact of electroweak corrections of infrared origin on strongly interacting longitudinal gauge boson scattering, calculating all-order resummed expressions at the double log level. As a working example, we consider the standard model with a heavy Higgs. At energies typical of forthcoming experiments (LHC, International Linear Collider, Compact Linear Collider), the corrections are in the 10%-40% range, with the relative sign depending on the initial state considered and on whether or not additional gauge boson emission is included. We conclude that the effect of radiative electroweak corrections should be included in the analysis of longitudinal gauge boson scattering.

  9. 25 CFR 542.7 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... by the Tribal gaming regulatory authority, will be acceptable. (b) Game play standards. (1) The... procedures that ensure the correct calling of numbers selected in the bingo game. (5) Each ball shall be.... For speed bingo games not verified by camera equipment, each ball drawn shall be verified by a person...

  10. 25 CFR 542.7 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... by the Tribal gaming regulatory authority, will be acceptable. (b) Game play standards. (1) The... procedures that ensure the correct calling of numbers selected in the bingo game. (5) Each ball shall be.... For speed bingo games not verified by camera equipment, each ball drawn shall be verified by a person...

  11. Autocalibrating motion-corrected wave-encoding for highly accelerated free-breathing abdominal MRI.

    PubMed

    Chen, Feiyu; Zhang, Tao; Cheng, Joseph Y; Shi, Xinwei; Pauly, John M; Vasanawala, Shreyas S

    2017-11-01

    To develop a motion-robust wave-encoding technique for highly accelerated free-breathing abdominal MRI. A comprehensive 3D wave-encoding-based method was developed to enable fast free-breathing abdominal imaging: (a) auto-calibration for wave-encoding was designed to avoid extra scan for coil sensitivity measurement; (b) intrinsic butterfly navigators were used to track respiratory motion; (c) variable-density sampling was included to enable compressed sensing; (d) golden-angle radial-Cartesian hybrid view-ordering was incorporated to improve motion robustness; and (e) localized rigid motion correction was combined with parallel imaging compressed sensing reconstruction to reconstruct the highly accelerated wave-encoded datasets. The proposed method was tested on six subjects and image quality was compared with standard accelerated Cartesian acquisition both with and without respiratory triggering. Inverse gradient entropy and normalized gradient squared metrics were calculated, testing whether image quality was improved using paired t-tests. For respiratory-triggered scans, wave-encoding significantly reduced residual aliasing and blurring compared with standard Cartesian acquisition (metrics suggesting P < 0.05). For non-respiratory-triggered scans, the proposed method yielded significantly better motion correction compared with standard motion-corrected Cartesian acquisition (metrics suggesting P < 0.01). The proposed methods can reduce motion artifacts and improve overall image quality of highly accelerated free-breathing abdominal MRI. Magn Reson Med 78:1757-1766, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. [Internal audit in medical laboratory: what means of control for an effective audit process?].

    PubMed

    Garcia-Hejl, Carine; Chianéa, Denis; Dedome, Emmanuel; Sanmartin, Nancy; Bugier, Sarah; Linard, Cyril; Foissaud, Vincent; Vest, Philippe

    2013-01-01

    To prepare the French Accreditation Committee (COFRAC) visit for initial certification of our medical laboratory, our direction evaluated its quality management system (QMS) and all its technical activities. This evaluation was performed owing an internal audit. This audit was outsourced. Auditors had an expertise in audit, a whole knowledge of biological standards and were independent. Several nonconformities were identified at that time, including a lack of control of several steps of the internal audit process. Hence, necessary corrective actions were taken in order to meet the requirements of standards, in particular, the formalization of all stages, from the audit program, to the implementation, review and follow-up of the corrective actions taken, and also the implementation of the resources needed to carry out audits in a pre-established timing. To ensure an optimum control of each step, the main concepts of risk management were applied: process approach, root cause analysis, effects and criticality analysis (FMECA). After a critical analysis of our practices, this methodology allowed us to define our "internal audit" process, then to formalize it and to follow it up, with a whole documentary system.

  13. Application of Internal Standard Method for Several 3d-Transition Metallic Elements in Flame Atomic Absorption Spectrometry Using a Multi-wavelength High-resolution Spectrometer.

    PubMed

    Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki

    2017-01-01

    We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum-group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.

  14. Soils Project Risk-Based Corrective Action Evaluation Process with ROTC 1 and ROTC 2, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick; Sloop, Christina

    2012-04-01

    This document formally defines and clarifies the NDEP-approved process the NNSA/NSO Soils Activity uses to fulfill the requirements of the FFACO and state regulations. This process is used to establish FALs in accordance with the risk-based corrective action (RBCA) process stipulated in Chapter 445 of the Nevada Administrative Code (NAC) as described in the ASTM International (ASTM) Method E1739-95 (NAC, 2008; ASTM, 1995). It is designed to provide a set of consistent standards for chemical and radiological corrective actions.

  15. An in-depth evaluation of accuracy and precision in Hg isotopic analysis via pneumatic nebulization and cold vapor generation multi-collector ICP-mass spectrometry.

    PubMed

    Rua-Ibarz, Ana; Bolea-Fernandez, Eduardo; Vanhaecke, Frank

    2016-01-01

    Mercury (Hg) isotopic analysis via multi-collector inductively coupled plasma (ICP)-mass spectrometry (MC-ICP-MS) can provide relevant biogeochemical information by revealing sources, pathways, and sinks of this highly toxic metal. In this work, the capabilities and limitations of two different sample introduction systems, based on pneumatic nebulization (PN) and cold vapor generation (CVG), respectively, were evaluated in the context of Hg isotopic analysis via MC-ICP-MS. The effect of (i) instrument settings and acquisition parameters, (ii) concentration of analyte element (Hg), and internal standard (Tl)-used for mass discrimination correction purposes-and (iii) different mass bias correction approaches on the accuracy and precision of Hg isotope ratio results was evaluated. The extent and stability of mass bias were assessed in a long-term study (18 months, n = 250), demonstrating a precision ≤0.006% relative standard deviation (RSD). CVG-MC-ICP-MS showed an approximately 20-fold enhancement in Hg signal intensity compared with PN-MC-ICP-MS. For CVG-MC-ICP-MS, the mass bias induced by instrumental mass discrimination was accurately corrected for by using either external correction in a sample-standard bracketing approach (SSB) or double correction, consisting of the use of Tl as internal standard in a revised version of the Russell law (Baxter approach), followed by SSB. Concomitant matrix elements did not affect CVG-ICP-MS results. Neither with PN, nor with CVG, any evidence for mass-independent discrimination effects in the instrument was observed within the experimental precision obtained. CVG-MC-ICP-MS was finally used for Hg isotopic analysis of reference materials (RMs) of relevant environmental origin. The isotopic composition of Hg in RMs of marine biological origin testified of mass-independent fractionation that affected the odd-numbered Hg isotopes. While older RMs were used for validation purposes, novel Hg isotopic data are provided for the latest generations of some biological RMs.

  16. Diagnostic Performance of a Novel Coronary CT Angiography Algorithm: Prospective Multicenter Validation of an Intracycle CT Motion Correction Algorithm for Diagnostic Accuracy.

    PubMed

    Andreini, Daniele; Lin, Fay Y; Rizvi, Asim; Cho, Iksung; Heo, Ran; Pontone, Gianluca; Bartorelli, Antonio L; Mushtaq, Saima; Villines, Todd C; Carrascosa, Patricia; Choi, Byoung Wook; Bloom, Stephen; Wei, Han; Xing, Yan; Gebow, Dan; Gransar, Heidi; Chang, Hyuk-Jae; Leipsic, Jonathon; Min, James K

    2018-06-01

    Motion artifact can reduce the diagnostic accuracy of coronary CT angiography (CCTA) for coronary artery disease (CAD). The purpose of this study was to compare the diagnostic performance of an algorithm dedicated to correcting coronary motion artifact with the performance of standard reconstruction methods in a prospective international multicenter study. Patients referred for clinically indicated invasive coronary angiography (ICA) for suspected CAD prospectively underwent an investigational CCTA examination free from heart rate-lowering medications before they underwent ICA. Blinded core laboratory interpretations of motion-corrected and standard reconstructions for obstructive CAD (≥ 50% stenosis) were compared with ICA findings. Segments unevaluable owing to artifact were considered obstructive. The primary endpoint was per-subject diagnostic accuracy of the intracycle motion correction algorithm for obstructive CAD found at ICA. Among 230 patients who underwent CCTA with the motion correction algorithm and standard reconstruction, 92 (40.0%) had obstructive CAD on the basis of ICA findings. At a mean heart rate of 68.0 ± 11.7 beats/min, the motion correction algorithm reduced the number of nondiagnostic scans compared with standard reconstruction (20.4% vs 34.8%; p < 0.001). Diagnostic accuracy for obstructive CAD with the motion correction algorithm (62%; 95% CI, 56-68%) was not significantly different from that of standard reconstruction on a per-subject basis (59%; 95% CI, 53-66%; p = 0.28) but was superior on a per-vessel basis: 77% (95% CI, 74-80%) versus 72% (95% CI, 69-75%) (p = 0.02). The motion correction algorithm was superior in subgroups of patients with severely obstructive (≥ 70%) stenosis, heart rate ≥ 70 beats/min, and vessels in the atrioventricular groove. The motion correction algorithm studied reduces artifacts and improves diagnostic performance for obstructive CAD on a per-vessel basis and in selected subgroups on a per-subject basis.

  17. Development of primary standards for mass spectrometry to increase accuracy in quantifying environmental contaminants.

    PubMed

    Oates, R P; Mcmanus, Michelle; Subbiah, Seenivasan; Klein, David M; Kobelski, Robert

    2017-07-14

    Internal standards are essential in electrospray ionization liquid chromatography-mass spectrometry (ESI-LC-MS) to correct for systematic error associated with ionization suppression and/or enhancement. A wide array of instrument setups and interfaces has created difficulty in comparing the quantitation of absolute analyte response across laboratories. This communication demonstrates the use of primary standards as operational qualification standards for LC-MS instruments and their comparison with commonly accepted internal standards. In monitoring the performance of internal standards for perfluorinated compounds, potassium hydrogen phthalate (KHP) presented lower inter-day variability in instrument response than a commonly accepted deuterated perfluorinated internal standard (d3-PFOS), with percent relative standard deviations less than or equal to 6%. The inter-day precision of KHP was greater than d3-PFOS over a 28-day monitoring of perfluorooctanesulfonic acid (PFOS), across concentrations ranging from 0 to 100μg/L. The primary standard trometamol (Trizma) performed as well as known internal standards simeton and tris (2-chloroisopropyl) phosphate (TCPP), with intra-day precision of Trizma response as low as 7% RSD on day 28. The inter-day precision of Trizma response was found to be greater than simeton and TCPP, across concentrations of neonicotinoids ranging from 1 to 100μg/L. This study explores the potential of primary standards to be incorporated into LC-MS/MS methodology to improve the quantitative accuracy in environmental contaminant analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. The Calibration of Gloss Reference Standards

    NASA Astrophysics Data System (ADS)

    Budde, W.

    1980-04-01

    In present international and national standards for the measurement of specular gloss the primary and secondary reference standards are defined for monochromatic radiation. However the glossmeter specified is using polychromatic radiation (CIE Standard Illuminant C) and the CIE Standard Photometric Observer. This produces errors in practical gloss measurements of up to 0.5%. Although this may be considered small as compared to the accuracy of most practical gloss measurements, such an error should not be tolerated in the calibration of secondary standards. Corrections for such errors are presented and various alternatives for amendments of the existing documentary standards are discussed.

  19. Extension of the International Atomic Energy Agency phantom study in image quantification: results of multicentre evaluation in Croatia.

    PubMed

    Grošev, Darko; Gregov, Marin; Wolfl, Miroslava Radić; Krstonošić, Branislav; Debeljuh, Dea Dundara

    2018-06-07

    To make quantitative methods of nuclear medicine more available, four centres in Croatia participated in the national intercomparison study, following the materials and methods used in the previous international study organized by the International Atomic Energy Agency (IAEA). The study task was to calculate the activities of four Ba sources (T1/2=10.54 years; Eγ=356 keV) using planar and single-photon emission computed tomography (SPECT) or SPECT/CT acquisitions of the sources inside a water-filled cylindrical phantom. The sources were previously calibrated by the US National Institute of Standards and Technology. Triple-energy window was utilized for scatter correction. Planar studies were corrected for attenuation correction (AC) using the conjugate-view method. For SPECT/CT studies, data from X-ray computed tomography were used for attenuation correction (CT-AC), whereas for SPECT-only acquisition, the Chang-AC method was applied. Using the lessons learned from the IAEA study, data were acquired according to the harmonized data acquisition protocol, and the acquired images were then processed using centralized data analysis. The accuracy of the activity quantification was evaluated as the ratio R between the calculated activity and the value obtained from National Institute of Standards and Technology. For planar studies, R=1.06±0.08; for SPECT/CT study using CT-AC, R=1.00±0.08; and for Chang-AC, R=0.89±0.12. The results are in accordance with those obtained within the larger IAEA study and confirm that SPECT/CT method is the most appropriate for accurate activity quantification.

  20. Validation of an isotope dilution, ICP-MS method based on internal mass bias correction for the determination of trace concentrations of Hg in sediment cores.

    PubMed

    Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E

    2008-01-15

    The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.

  1. Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.

    PubMed

    Carter, J F; Fry, B

    2013-03-01

    The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.

  2. What is the force on a magnetic dipole?

    NASA Astrophysics Data System (ADS)

    Franklin, Jerrold

    2018-05-01

    This paper will be of interest to physics graduate students and faculty. We show that attempts to modify the force on a magnetic dipole by introducing either hidden momentum or internal forces are not correct. The standard textbook result {F}={{\

  3. 25 CFR 542.8 - What are the minimum internal control standards for pull tabs?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... microchip reader, the reader shall be tested periodically to determine that it is correctly reading the bar code or microchip. (iii) If the electronic equipment returns a voucher or a payment slip to the player...

  4. Correction factors for the ISO rod phantom, a cylinder phantom, and the ICRU sphere for reference beta radiation fields of the BSS 2

    NASA Astrophysics Data System (ADS)

    Behrens, R.

    2015-03-01

    The International Organization for Standardization (ISO) requires in its standard ISO 6980 that beta reference radiation fields for radiation protection be calibrated in terms of absorbed dose to tissue at a depth of 0.07 mm in a slab phantom (30 cm x 30 cm x 15 cm). However, many beta dosemeters are ring dosemeters and are, therefore, irradiated on a rod phantom (1.9 cm in diameter and 30 cm long), or they are eye dosemeters possibly irradiated on a cylinder phantom (20 cm in diameter and 20 cm high), or area dosemeters irradiated free in air with the conventional quantity value (true value) being defined in a sphere (30 cm in diameter, made of ICRU tissue (International Commission on Radiation Units and Measurements)). Therefore, the correction factors for the conventional quantity value in the rod, the cylinder, and the sphere instead of the slab (all made of ICRU tissue) were calculated for the radiation fields of 147Pm, 85Kr, 90Sr/90Y, and, 106Ru/106Rh sources of the beta secondary standard BSS 2 developed at PTB. All correction factors were calculated for 0° up to 75° (in steps of 15°) radiation incidence. The results are ready for implementation in ISO 6980-3 and have recently been (partly) implemented in the software of the BSS 2.

  5. PACS photometer calibration block analysis

    NASA Astrophysics Data System (ADS)

    Moór, A.; Müller, T. G.; Kiss, C.; Balog, Z.; Billot, N.; Marton, G.

    2014-07-01

    The absolute stability of the PACS bolometer response over the entire mission lifetime without applying any corrections is about 0.5 % (standard deviation) or about 8 % peak-to-peak. This fantastic stability allows us to calibrate all scientific measurements by a fixed and time-independent response file, without using any information from the PACS internal calibration sources. However, the analysis of calibration block observations revealed clear correlations of the internal source signals with the evaporator temperature and a signal drift during the first half hour after the cooler recycling. These effects are small, but can be seen in repeated measurements of standard stars. From our analysis we established corrections for both effects which push the stability of the PACS bolometer response to about 0.2 % (stdev) or 2 % in the blue, 3 % in the green and 5 % in the red channel (peak-to-peak). After both corrections we still see a correlation of the signals with PACS FPU temperatures, possibly caused by parasitic heat influences via the Kevlar wires which connect the bolometers with the PACS Focal Plane Unit. No aging effect or degradation of the photometric system during the mission lifetime has been found.

  6. Tracking occupational hearing loss across global industries: A comparative analysis of metrics

    PubMed Central

    Rabinowitz, Peter M.; Galusha, Deron; McTague, Michael F.; Slade, Martin D.; Wesdock, James C.; Dixon-Ernst, Christine

    2013-01-01

    Occupational hearing loss is one of the most prevalent occupational conditions; yet, there is no acknowledged international metric to allow comparisons of risk between different industries and regions. In order to make recommendations for an international standard of occupational hearing loss, members of an international industry group (the International Aluminium Association) submitted details of different hearing loss metrics currently in use by members. We compared the performance of these metrics using an audiometric data set for over 6000 individuals working in 10 locations of one member company. We calculated rates for each metric at each location from 2002 to 2006. For comparison, we calculated the difference of observed–expected (for age) binaural high frequency hearing loss (in dB/year) for each location over the same time period. We performed linear regression to determine the correlation between each metric and the observed–expected rate of hearing loss. The different metrics produced discrepant results, with annual rates ranging from 0.0% for a less-sensitive metric to more than 10% for a highly sensitive metric. At least two metrics, a 10 dB age-corrected threshold shift from baseline and a 15 dB nonage-corrected shift metric, correlated well with the difference of observed–expected high-frequency hearing loss. This study suggests that it is feasible to develop an international standard for tracking occupational hearing loss in industrial working populations. PMID:22387709

  7. Pressure standards and sensors up to 3 GPa, actual state and development trends

    NASA Astrophysics Data System (ADS)

    Wisniewski, Roland; Molinar, Gianfranco

    1999-04-01

    Metrological problems connected with pressure standards and sensors up to 3 GPa as an introduction to the pressure measurements in the so-called “GIGAPASCAL REGION”, 1-100 GPa, are discussed. Re-examination of Bi I-Bi II phase transition pressure as a fixed point of the International Practical Pressure Scale and correction of the NaCl Pressure Scale is proposed. Well-established sensors as candidates for secondary pressure standards up to 3 GPa are briefly presented.

  8. [Comprehension of hazard pictograms of chemical products among cleaning workers].

    PubMed

    Martí Fernández, Francesc; van der Haar, Rudolf; López López, Juan Carlos; Portell, Mariona; Torner Solé, Anna

    2015-01-01

    To assess the comprehension among cleaning workers of the hazard pictograms as defined by the Globally Harmonized System (GHS) of the United Nations, concerning the classification, labeling and packaging of substances and mixtures. A sample of 118 workers was surveyed on their perception of the GHS hazard pictograms. Comprehensibility was measured by the percentage of correct answers and the degree to which they reflected International Organization for Standardization and American National Standards Institute standards for minimum level of comprehension. The influence of different variables to predict comprehension capacity was assessed using a logistic regression model. Three groups of pictograms could be distinguished which were statistically differentiated by their comprehensibility. Pictograms reflecting "acute toxicity" and "flammable", were described correctly by 94% and 95% of the surveyed population, respectively. For pictograms reflecting "systemic toxicity", "corrosive", "warning", "environment" and "explosive" the frequency of correct answers ranged from 48% to 64%, whereas those for pictograms "oxidizing" and "compressed gas" were interpreted correctly by only 7% of respondents. Prognostic factors for poor comprehension included: not being familiar with the pictograms, not having received training on safe use of chemical products, being an immigrant and being 54 years of age or older. Only two pictograms exceeded minimum standards for comprehension. Training, a tool proven to be effective to improve the correct interpretation of danger symbols, should be encouraged, especially in those groups with greater comprehension difficulties. Copyright belongs to the Societat Catalana de Salut Laboral.

  9. Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr.

    PubMed

    Horsky, Monika; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    This paper critically reviews the state-of-the-art of isotope amount ratio measurements by solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) and presents guidelines for corresponding data reduction strategies and uncertainty assessments based on the example of n((87)Sr)/n((86)Sr) isotope ratios. This ratio shows variation attributable to natural radiogenic processes and mass-dependent fractionation. The applied calibration strategies can display these differences. In addition, a proper statement of uncertainty of measurement, including all relevant influence quantities, is a metrological prerequisite. A detailed instructive procedure for the calculation of combined uncertainties is presented for Sr isotope amount ratios using three different strategies of correction for instrumental isotopic fractionation (IIF): traditional internal correction, standard-sample bracketing, and a combination of both, using Zr as internal standard. Uncertainties are quantified by means of a Kragten spreadsheet approach, including the consideration of correlations between individual input parameters to the model equation. The resulting uncertainties are compared with uncertainties obtained from the partial derivatives approach and Monte Carlo propagation of distributions. We obtain relative expanded uncertainties (U rel; k = 2) of n((87)Sr)/n((86)Sr) of < 0.03 %, when normalization values are not propagated. A comprehensive propagation, including certified values and the internal normalization ratio in nature, increases relative expanded uncertainties by about factor two and the correction for IIF becomes the major contributor.

  10. Isostatic gravity map of the Nevada Test Site and vicinity, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ponce, D.A.; Harris, R.N.; Oliver, H.W.

    1988-12-31

    The isostatic gravity map of the Nevada Test Site (NTS) and vicinity is based on about 16,000 gravity stations. Principal facts of the gravity data were listed by Harris and others (1989) and their report included descriptions of base stations, high-precision and absolute gravity stations, and data accuracy. Observed gravity values were referenced to the International Gravity Standardization Net 1971 gravity datum described by Morelli (1974) and reduced using the Geodetic Reference System 1967 formula for the normal gravity on the ellipsoid (International Union of Geodesy and Geophysics, 1971). Free-air, Bouguer, curvature, and terrain corrections for a standard reduction densitymore » of 2.67 g/cm{sup 3} were made to compute complete Bouguer anomalies. Terrain corrections were made to a radial distance of 166.7 km from each station using a digital elevation model and a computer procedure by Plouff (1977) and, in general, include manually estimated inner-zone terrain corrections. Finally, isostatic corrections were made using a procedure by Simpson and others (1983) based on an Airy-Heiskanen model with local compensation (Heiskanen and Moritz, 1967) with an upper-crustal density of 2.67 g/cm{sup 3}, a crustal thickness of 25 km, and a density contrast between the lower-crust and upper-mantle of 0.4 g/cm{sup 3}. Isostatic corrections help remove the effects of long-wavelength anomalies related to topography and their compensating masses and, thus, enhance short- to moderate-wavelength anomalies caused by near surface geologic features. 6 refs.« less

  11. 22 CFR 1006.860 - What factors may influence the debarring official's decision?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... official may consider when the cooperation began and whether you disclosed all pertinent information known... corrective action or remedial measures, such as establishing ethics training and implementing programs to... you had effective standards of conduct and internal control systems in place at the time the...

  12. 34 CFR 85.860 - What factors may influence the debarring official's decision?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... official may consider when the cooperation began and whether you disclosed all pertinent information known... corrective action or remedial measures, such as establishing ethics training and implementing programs to... you had effective standards of conduct and internal control systems in place at the time the...

  13. 22 CFR 1508.860 - What factors may influence the debarring official's decision?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... official may consider when the cooperation began and whether you disclosed all pertinent information known... corrective action or remedial measures, such as establishing ethics training and implementing programs to... you had effective standards of conduct and internal control systems in place at the time the...

  14. 22 CFR 208.860 - What factors may influence the debarring official's decision?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... official may consider when the cooperation began and whether you disclosed all pertinent information known... corrective action or remedial measures, such as establishing ethics training and implementing programs to... you had effective standards of conduct and internal control systems in place at the time the...

  15. 29 CFR 1471.860 - What factors may influence the debarring official's decision?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... disclosed all pertinent information known to you. (j) Whether the wrongdoing was pervasive within your... organization took appropriate corrective action or remedial measures, such as establishing ethics training and.... (p) Whether you had effective standards of conduct and internal control systems in place at the time...

  16. Translations of volcanological terms: cross-cultural standards for teaching, communication, and reporting

    NASA Astrophysics Data System (ADS)

    Harris, Andrew J. L.; Belousov, Alexander; Calvari, Sonia; Delgado-Granados, Hugo; Hort, Matthias; Koga, Ken; Wulan Mei, Estuning Tyas; Harijoko, Agung; Pacheco, José; Prival, Jean-Marie; Solana, Carmen; Þórðarson, Þorvaldur; Thouret, Jean-Claude; van Wyk de Vries, Benjamin

    2017-07-01

    When teaching at a non-English language university, we often argue that because English is the international language, students need to become familiar with English terms, even if the bulk of the class is in the native language. However, to make the meaning of the terms clear, a translation into the native language is always useful. Correct translation of terminology is even more crucial for emergency managers and decision makers who can be confronted with a confusing and inconsistently applied mix of terminology. Thus, it is imperative to have a translation that appropriately converts the meaning of a term, while being grammatically and lexicologically correct, before the need for use. If terms are not consistently defined across all languages following industry standards and norms, what one person believes to be a dog, to another is a cat. However, definitions and translations of English scientific and technical terms are not always available, and language is constantly evolving. We live and work in an international world where English is the common language of multi-cultural exchange. As a result, while finding the correct translation can be difficult because we are too used to the English language terms, translated equivalents that are available may not have been through the peer review process. We have explored this issue by discussing grammatically and lexicologically correct French, German, Icelandic, Indonesian, Italian, Portuguese, Russian, Spanish, and Japanese versions for terms involved in communicating effusive eruption intensity.

  17. The emergence of international food safety standards and guidelines: understanding the current landscape through a historical approach.

    PubMed

    Ramsingh, Brigit

    2014-07-01

    Following the Second World War, the Food and Agriculture Organization (FAO) and the World Health Organization (WHO) teamed up to construct an International Codex Alimentarius (or 'food code') which emerged in 1963. The Codex Committee on Food Hygiene (CCFH) was charged with the task of developing microbial hygiene standards, although it found itself embroiled in debate with the WHO over the nature these standards should take. The WHO was increasingly relying upon the input of biometricians and especially the International Commission on Microbial Specifications for Foods (ICMSF) which had developed statistical sampling plans for determining the microbial counts in the final end products. The CCFH, however, was initially more focused on a qualitative approach which looked at the entire food production system and developed codes of practice as well as more descriptive end-product specifications which the WHO argued were 'not scientifically correct'. Drawing upon historical archival material (correspondence and reports) from the WHO and FAO, this article examines this debate over microbial hygiene standards and suggests that there are many lessons from history which could shed light upon current debates and efforts in international food safety management systems and approaches.

  18. Avoiding Pitfalls of Tibiotalocalcaneal Nail Malposition With Internal Rotation Axial Heel View.

    PubMed

    Callahan, Ryan; Juliano, Paul; Aydogan, Umur; Clayton, Justin

    2018-04-01

    Tibiotalocalcaneal (TTC) nails are often used for complex hind foot arthrodesis and deformity correction. The natural valgus alignment of the hindfoot creates a challenge to optimum placement of the guidewire and eventual nail with a straight or valgus-curved nail. Five fresh frozen cadavers were used for placement of a TTC guidewire with standard anterior-posterior (AP), lateral, and Harris axial heel views as a reference for proper placement. The limb was then rotated 15°, 30°, and 45° both internally and externally to evaluate the perceived amount of osseous purchase within the calcaneus. The TTC nail was then inserted and dissection was performed to demonstrate proximity of the nail to the sustentaculum tali and neurovascular structures. A 30° internal rotation Harris axial heel view demonstrated the most accurate representation of osseous purchase within the calcaneus with the guidewire and nail placement. When the guidewire was placed with standard imaging the nail was often ultimately placed in close proximity to the sustentaculum tali and neurovascular structures. Careful placement of the guidewire prior to reaming and nail placement should be undertaken to avoid neurovascular injury and to increase osseous purchase. For optimal guidewire placement, the authors suggest using appropriate anatomic landmarks and using a 30° internally rotated Harris axial heel view to verify correct placement. Level V: Expert opinion.

  19. Dosimetry for Small and Nonstandard Fields

    NASA Astrophysics Data System (ADS)

    Junell, Stephanie L.

    The proposed small and non-standard field dosimetry protocol from the joint International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine working group introduces new reference field conditions for ionization chamber based reference dosimetry. Absorbed dose beam quality conversion factors (kQ factors) corresponding to this formalism were determined for three different models of ionization chambers: a Farmer-type ionization chamber, a thimble ionization chamber, and a small volume ionization chamber. Beam quality correction factor measurements were made in a specially developed cylindrical polymethyl methacrylate (PMMA) phantom and a water phantom using thermoluminescent dosimeters (TLDs) and alanine dosimeters to determine dose to water. The TLD system for absorbed dose to water determination in high energy photon and electron beams was fully characterized as part of this dissertation. The behavior of the beam quality correction factor was observed as it transfers the calibration coefficient from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) 60Co reference beam to the small field calibration conditions of the small field formalism. TLD-determined beam quality correction factors for the calibration conditions investigated ranged from 0.97 to 1.30 and had associated standard deviations from 1% to 3%. The alanine-determined beam quality correction factors ranged from 0.996 to 1.293. Volume averaging effects were observed with the Farmer-type ionization chamber in the small static field conditions. The proposed small and non-standard field dosimetry protocols new composite-field reference condition demonstrated its potential to reduce or remove ionization chamber volume dependancies, but the measured beam quality correction factors were not equal to the standard CoP's kQ, indicating a change in beam quality in the small and non-standard field dosimetry protocols new composite-field reference condition relative to the standard broad beam reference conditions. The TLD- and alanine-determined beam quality correction factors in the composite-field reference conditions were approximately 3% greater and differed by more than one standard deviation from the published TG-51 kQ values for all three chambers.

  20. World Health Organization-World Federation of Societies of Anaesthesiologists (WHO-WFSA) International Standards for a Safe Practice of Anesthesia.

    PubMed

    Gelb, Adrian W; Morriss, Wayne W; Johnson, Walter; Merry, Alan F; Abayadeera, Anuja; Belîi, Natalia; Brull, Sorin J; Chibana, Aline; Evans, Faye; Goddia, Cyril; Haylock-Loor, Carolina; Khan, Fauzia; Leal, Sandra; Lin, Nan; Merchant, Richard; Newton, Mark W; Rowles, Jackie S; Sanusi, Arinola; Wilson, Iain; Velazquez Berumen, Adriana

    2018-06-01

    The International Standards for a Safe Practice of Anesthesia were developed on behalf of the World Federation of Societies of Anaesthesiologists (WFSA), a nonprofit organization representing anesthesiologists in 150 countries, and the World Health Organization (WHO). The recommendations have been approved by WHO and the membership of WFSA. These Standards are applicable to all anesthesia providers throughout the world. They are intended to provide guidance and assistance to anesthesia providers, their professional organizations, hospital and facility administrators, and governments for maintaining and improving the quality and safety of anesthesia care. The Standards cover professional aspects; facilities and equipment; medications and intravenous fluids; monitoring; and the conduct of anesthesia. HIGHLY RECOMMENDED standards, the functional equivalent of mandatory standards, include (amongst other things): the continuous presence of a trained and vigilant anesthesia provider; continuous monitoring of tissue oxygenation and perfusion by clinical observation and a pulse oximeter; intermittent monitoring of blood pressure; confirmation of correct placement of an endotracheal tube (if used) by auscultation and carbon dioxide detection; the use of the WHO Safe Surgery Checklist; and a system for transfer of care at the end of an anesthetic. The International Standards represent minimum standards and the goal should always be to practice to the highest possible standards, preferably exceeding the standards outlined in this document.

  1. World Health Organization-World Federation of Societies of Anaesthesiologists (WHO-WFSA) International Standards for a Safe Practice of Anesthesia.

    PubMed

    Gelb, Adrian W; Morriss, Wayne W; Johnson, Walter; Merry, Alan F

    2018-05-07

    The International Standards for a Safe Practice of Anesthesia were developed on behalf of the World Federation of Societies of Anaesthesiologists (WFSA), a non-profit organization representing anesthesiologists in 150 countries, and the World Health Organization (WHO). The recommendations have been approved by WHO and the membership of WFSA. These Standards are applicable to all anesthesia providers throughout the world. They are intended to provide guidance and assistance to anesthesia providers, their professional organizations, hospital and facility administrators, and governments for maintaining and improving the quality and safety of anesthesia care. The Standards cover professional aspects; facilities and equipment; medications and intravenous fluids; monitoring; and the conduct of anesthesia. HIGHLY RECOMMENDED standards, the functional equivalent of mandatory standards, include (amongst other things): the continuous presence of a trained and vigilant anesthesia provider; continuous monitoring of tissue oxygenation and perfusion by clinical observation and a pulse oximeter; intermittent monitoring of blood pressure; confirmation of correct placement of an endotracheal tube (if used) by auscultation and carbon dioxide detection; the use of the WHO Safe Surgery Checklist; and a system for transfer of care at the end of an anesthetic. The International Standards represent minimum standards and the goal should always be to practice to the highest possible standards, preferably exceeding the standards outlined in this document.

  2. Up-regulation of the G3PDH 'housekeeping' gene by estrogen.

    PubMed

    Galal, Nadia; El-Beialy, Waleed; Deyama, Yoshiaki; Yoshimura, Yoshitaka; Tei, Kanchu; Suzuki, Kuniaki; Totsuka, Yasunori

    2010-01-01

    Proteomic and genomic studies commonly involve the assessment of mRNA levels using reverse transcription-polymerase chain reaction (PCR) and real-time quantitative PCR. An internal standard RNA is fundamentally analyzed along with the investigated mRNA to document the specificity of the effect(s) on mRNA and to correct for inter-sample variations. In our studies implementing estrogen treatments on different cell lines, we initially used glyceraldehyde-3-phosphate dehydrogenase (G3PDH) as an internal standard. However, the results of PCR amplification demonstrated that 17β-estradiol enhanced the expression of the G3PDH gene, rendering it impossible to use G3PDH as an unbiased comparative control.

  3. Guidelines for the detection of Trichinella larvae at the slaughterhouse in a quality assurance system.

    PubMed

    Rossi, Patrizia; Pozio, Edoardo

    2008-01-01

    The European Community Regulation (EC) No. 2075/2005 lays down specific rules on official controls for the detection of Trichinella in fresh meat for human consumption, recommending the pooled-sample digestion method as the reference method. The aim of this document is to provide specific guidance to implement an appropriate Trichinella digestion method by a laboratory accredited according to the ISO/IEC 17025:2005 international standard, and performing microbiological testing following the EA-04/10:2002 international guideline. Technical requirements for the correct implementation of the method, such as the personnel competence, specific equipments and reagents, validation of the method, reference materials, sampling, quality assurance of results and quality control of performance are provided, pointing out the critical control points for the correct implementation of the digestion method.

  4. 77 FR 52393 - Petition for Exemption From the Vehicle Theft Prevention Standard; BMW of North America, LLC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ... International Policy, Fuel Economy and Consumer Programs, National Highway Traffic Safety Administration, 1200... key, powered by a battery and consists of a transmitter/receiver which communicates with the EWS... and starter. The ignition and fuel supply are only released when a correct coded release signal has...

  5. 75 FR 37732 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-30

    ... procedure are impracticable, unnecessary, or contrary to the public interest, the Agency may issue a rule... because this action only corrects a simple and obvious instructional error that would cause a change that... impracticable, unnecessary, or contrary to the public interest. This determination must be supported by a brief...

  6. Impact of and correction for instrument sensitivity drift on nanoparticle size measurements by single-particle ICP-MS

    PubMed Central

    El Hadri, Hind; Petersen, Elijah J.; Winchester, Michael R.

    2016-01-01

    The effect of ICP-MS instrument sensitivity drift on the accuracy of NP size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 nm and 60 nm gold nanoparticles. PMID:26894759

  7. Information Systems Security Management: A Review and a Classification of the ISO Standards

    NASA Astrophysics Data System (ADS)

    Tsohou, Aggeliki; Kokolakis, Spyros; Lambrinoudakis, Costas; Gritzalis, Stefanos

    The need for common understanding and agreement of functional and non-functional requirements is well known and understood by information system designers. This is necessary for both: designing the "correct" system and achieving interoperability with other systems. Security is maybe the best example of this need. If the understanding of the security requirements is not the same for all involved parties and the security mechanisms that will be implemented do not comply with some globally accepted rules and practices, then the system that will be designed will not necessarily achieve the desired security level and it will be very difficult to securely interoperate with other systems. It is therefore clear that the role and contribution of international standards to the design and implementation of security mechanisms is dominant. In this paper we provide a state of the art review on information security management standards published by the International Organization for Standardization and the International Electrotechnical Commission. Such an analysis is meaningful to security practitioners for an efficient management of information security. Moreover, the classification of the standards in the clauses of ISO/IEC 27001:2005 that results from our analysis is expected to provide assistance in dealing with the plethora of security standards.

  8. [Present regulation on infant and follow-on formula].

    PubMed

    Angulo Lucena, R; Gallego Domínguez, M C; Bentabol Manzanares, A; Jodral Villarejo, M

    1995-01-01

    The commercialization of breast milk substitutes has had great economic transcendence, sometimes without considering the sanitary and nutritional consequences for the customer. The sanitary authorities have been implied in this matter both in the International and European fields, issuing standards and regulations for the commercialization of breast milk substitutes which have been adopted by the Spanish Regulation. The aim of this paper is comment the regulations that affect foods for breast-feeding and short age children. This report analyzes and comments on the contents of international, european and national regulation on infant and follow-on formula. The regulations about Infant formula and Follow-on formula, banning the term of "humanized milk" and remarking the preference for breast feeding, which could only be substituted by sanitary professionals. This regulation deals with the appropriate chemical composition of these products, qualitative and quantitative. It includes standards for correct labeling, which should contain the appropriate information without idealizing the product Drawings and pictures showing the correct preparation are allowed. It provides for distribution and sales, as well as for correct advertising, which should be under control. This regulation also bans free samples and any other donation to particular customers or sanitary institutions. The present regulation on "Infant and Follow-on formulas" pursues the adequate nutrition of breast-feeding and short age children, being the protection of this kind of customers everyone's responsibility.

  9. Compensation of matrix effects in gas chromatography-mass spectrometry analysis of pesticides using a combination of matrix matching and multiple isotopically labeled internal standards.

    PubMed

    Tsuchiyama, Tomoyuki; Katsuhara, Miki; Nakajima, Masahiro

    2017-11-17

    In the multi-residue analysis of pesticides using GC-MS, the quantitative results are adversely affected by a phenomenon known as the matrix effect. Although the use of matrix-matched standards is considered to be one of the most practical solutions to this problem, complete removal of the matrix effect is difficult in complex food matrices owing to their inconsistency. As a result, residual matrix effects can introduce analytical errors. To compensate for residual matrix effects, we have developed a novel method that employs multiple isotopically labeled internal standards (ILIS). The matrix effects of ILIS and pesticides were evaluated in spiked matrix extracts of various agricultural commodities, and the obtained data were subjected to simple statistical analysis. Based on the similarities between the patterns of variation in the analytical response, a total of 32 isotopically labeled compounds were assigned to 338 pesticides as internal standards. It was found that by utilizing multiple ILIS, residual matrix effects could be effectively compensated. The developed method exhibited superior quantitative performance compared with the common single-internal-standard method. The proposed method is more feasible for regulatory purposes than that using only predetermined correction factors and is considered to be promising for practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. 77 FR 33811 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-07

    ... reduction requirement, the method used must be suitable for the entire range of emissions since pre and post... demand response. The proposed amendments also correct minor mistakes in the pre-existing regulations...: Submit your comments, identified by Docket ID No. EPA-HQ- OAR-2008-0708, by one of the following methods...

  11. Student performance of the general physical examination in internal medicine: an observational study.

    PubMed

    Haring, Catharina M; Cools, Bernadette M; van der Meer, Jos Wm; Postma, Cornelis T

    2014-04-08

    Many practicing physicians lack skills in physical examination. It is not known whether physical examination skills already show deficiencies after an early phase of clinical training. At the end of the internal medicine clerkship students are expected to be able to perform a general physical examination in every new patient encounter. In a previous study, the basic physical examination items that should standardly be performed were set by consensus. The aim of the current observational study was to assess whether medical students were able to correctly perform a general physical examination regarding completeness as well as technique at the end of the clerkship internal medicine. One hundred students who had just finished their clerkship internal medicine were asked to perform a general physical examination on a standardized patient as they had learned during the clerkship. They were recorded on camera. Frequency of performance of each component of the physical examination was counted. Adequacy of performance was determined as either correct or incorrect or not assessable using a checklist of short descriptions of each physical examination component. A reliability analysis was performed by calculation of the intra class correlation coefficient for total scores of five physical examinations rated by three trained physicians and for their agreement on performance of all items. Approximately 40% of the agreed standard physical examination items were not performed by the students. Students put the most emphasis on examination of general parameters, heart, lungs and abdomen. Many components of the physical examination were not performed as was taught during precourses. Intra-class correlation was high for total scores of the physical examinations 0.91 (p <0.001) and for agreement on performance of the five physical examinations (0.79-0.92 p <0.001). In conclusion, performance of the general physical examination was already below expectation at the end of the internal medicine clerkship. Possible causes and suggestions for improvement are discussed.

  12. Student performance of the general physical examination in internal medicine: an observational study

    PubMed Central

    2014-01-01

    Background Many practicing physicians lack skills in physical examination. It is not known whether physical examination skills already show deficiencies after an early phase of clinical training. At the end of the internal medicine clerkship students are expected to be able to perform a general physical examination in every new patient encounter. In a previous study, the basic physical examination items that should standardly be performed were set by consensus. The aim of the current observational study was to assess whether medical students were able to correctly perform a general physical examination regarding completeness as well as technique at the end of the clerkship internal medicine. Methods One hundred students who had just finished their clerkship internal medicine were asked to perform a general physical examination on a standardized patient as they had learned during the clerkship. They were recorded on camera. Frequency of performance of each component of the physical examination was counted. Adequacy of performance was determined as either correct or incorrect or not assessable using a checklist of short descriptions of each physical examination component. A reliability analysis was performed by calculation of the intra class correlation coefficient for total scores of five physical examinations rated by three trained physicians and for their agreement on performance of all items. Results Approximately 40% of the agreed standard physical examination items were not performed by the students. Students put the most emphasis on examination of general parameters, heart, lungs and abdomen. Many components of the physical examination were not performed as was taught during precourses. Intra-class correlation was high for total scores of the physical examinations 0.91 (p <0.001) and for agreement on performance of the five physical examinations (0.79-0.92 p <0.001). Conclusions In conclusion, performance of the general physical examination was already below expectation at the end of the internal medicine clerkship. Possible causes and suggestions for improvement are discussed. PMID:24712683

  13. [Determination of heavy metals in four traditional Chinese medicines by ICP-MS].

    PubMed

    Wen, Hui-Min; Chen, Xiao-Hui; Dong, Ting-Xia; Zhan, Hua-Qiang; Bi, Kai-Shun

    2006-08-01

    To establish a ICP-MS method for the determination of heavy metals, including As, Hg, Pb, Cd, in four traditional Chinese medicines. The samples were digested by closed-versel microwave. The four heavy metals were directly analyzed by ICP-MS. Select internal standard element in for the method by which the analyse signal drife is corrected by the signal of another element (internal standard elements) added to both the standard solution and sample. For all of the analyzed heary methals, the correlative coefficient of the calibration curves was over 0.999 2. The recovery rates of the procedure were 97.5%-108.0%, and its RSD was lower than 11.6%. This method was convenient, quick-acquired, accurate and highly sensitive. The method can be used for the quality control of trace elements in traditional Chinese medicines and for the contents determination of traditional Chinese medicines from different habitats and species.

  14. Laser-ablation ICP-MS as a tool for whole rock trace element analyses on fused powders

    NASA Astrophysics Data System (ADS)

    Girard, G.; Rooney, T. O.

    2013-12-01

    Here we present an accurate and precise technique for routine trace element analysis of geologic materials by laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). We focus on rock powders previously prepared for X-ray fluorescence by fusion in a Li2B4O7 flux, and subsequently quenched in a Pt mold to form a glass disk. Our method allows for the analysis up to 30 trace elements by LA-ICP-MS using a Photon-Machines Analyte G2 193 nm excimer laser coupled to a Thermo-Fisher Scientific ICAP Q quadrupole ICP-MS. Analyses are run as scans on the surface of the disks. Laser ablation conditions for which trace element fractionation effects are minimal have been empirically determined to be ~ 4 J m-2 fluence, at 10 Hz , and 10 μm s-1 scan speed, using a 110 μm laser beam size. Ablated material is carried into the ICP-MS by a He carrier at a rate of 0.75 L min-1. Following pre-ablation to remove surface particles, samples are ablated for 200 s, of which 140 s are used for data acquisition. At the end of each scan, a gas blank is collected for 30 s. Dwell times for each element vary between 15 and 60 μs, depending on abundance and instrument sensitivity, allowing 120 readings of each element during the data acquisition time window. To correct for variations in the total volume of material extracted by the laser, three internal standards are used, Ca, Fe and Zr. These elements are routinely analyzed by X-ray fluorescence by the Geoanalytical laboratory at Michigan State University with precision and accuracy of <5%. The availability of several internal standards allows for better correction of possible persisting laser ablation fractionation effects; for a particular trace element, we correct using the internal standard that best reproduces its ablation behavior. Our calibration is based on a combination of fused powders of US Geological Survey and Geological Survey of Japan rock standards, NIST SRM 612 glass, and US Geological Survey natural and synthetic basalt glasses. Instrumental drift is monitored during each run using two fused standards analyzed multiple times as unknowns. We routinely achieve an external precision of <5% on multiple replicates of standards run as unknowns, which are also within <5% of certified values. Elements analyzed include most first row transition metals, large ion lithophile elements, high field strength elements, lanthanide and actinide rare earth elements.

  15. Investigations of internal noise levels for different target sizes, contrasts, and noise structures

    NASA Astrophysics Data System (ADS)

    Han, Minah; Choi, Shinkook; Baek, Jongduk

    2014-03-01

    To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.

  16. Use of a deuterated internal standard with pyrolysis-GC/MS dimeric marker analysis to quantify tire tread particles in the environment.

    PubMed

    Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M

    2012-11-08

    Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.

  17. Method to Calculate Uncertainty Estimate of Measuring Shortwave Solar Irradiance using Thermopile and Semiconductor Solar Radiometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, I.

    2011-07-01

    The uncertainty of measuring solar irradiance is fundamentally important for solar energy and atmospheric science applications. Without an uncertainty statement, the quality of a result, model, or testing method cannot be quantified, the chain of traceability is broken, and confidence cannot be maintained in the measurement. Measurement results are incomplete and meaningless without a statement of the estimated uncertainty with traceability to the International System of Units (SI) or to another internationally recognized standard. This report explains how to use International Guidelines of Uncertainty in Measurement (GUM) to calculate such uncertainty. The report also shows that without appropriate corrections tomore » solar measuring instruments (solar radiometers), the uncertainty of measuring shortwave solar irradiance can exceed 4% using present state-of-the-art pyranometers and 2.7% using present state-of-the-art pyrheliometers. Finally, the report demonstrates that by applying the appropriate corrections, uncertainties may be reduced by at least 50%. The uncertainties, with or without the appropriate corrections might not be compatible with the needs of solar energy and atmospheric science applications; yet, this report may shed some light on the sources of uncertainties and the means to reduce overall uncertainty in measuring solar irradiance.« less

  18. Testing the internal consistency of the standard gamble in 'success' and 'failure' frames.

    PubMed

    Oliver, Adam

    2004-06-01

    Decision making behaviour has often been shown to vary following changes in the way in which choice problems are described (or 'framed'). Moreover, a number of researchers have demonstrated that the standard gamble is prone to internal inconsistency, and loss aversion has been proposed as an explanation for this observed bias. This study attempts to alter the influence of loss aversion by framing the treatment arm of the standard gamble in terms of success (where we may expect the influence of loss aversion to be relatively weak) and in terms of failure (where we may expect the influence of loss aversion to be relatively strong). The objectives of the study are (1) to test whether standard gamble values vary when structurally identical gambles are differentially framed, and (2) to test whether the standard gamble is equally prone to internal inconsistency across the two frames. The results show that compared to framing in terms of treatment success, significantly higher values were inferred when the gamble was framed in terms of treatment failure. However, there was no difference in the quite marked levels of internal inconsistency observed in both frames. It is possible that the essential construct of the standard gamble induces substantial and/or widespread loss aversion irrespective of the way in which the gamble is framed, which offers a fundamental challenge to the usefulness of this value elicitation instrument. It is therefore recommended that further tests are undertaken on more sophisticated corrective procedures designed to limit the influence of loss aversion.

  19. Estimating Uncertainties of Ship Course and Speed in Early Navigations using ICOADS3.0

    NASA Astrophysics Data System (ADS)

    Chan, D.; Huybers, P. J.

    2017-12-01

    Information on ship position and its uncertainty is potentially important for mapping out climatologists and changes in SSTs. Using the 2-hourly ship reports from the International Comprehensive Ocean Atmosphere Dataset 3.0 (ICOADS 3.0), we estimate the uncertainties of ship course, ship speed, and latitude/longitude corrections during 1870-1900. After reviewing the techniques used in early navigations, we build forward navigation model that uses dead reckoning technique, celestial latitude corrections, and chronometer longitude corrections. The modeled ship tracks exhibit jumps in longitude and latitude, when a position correction is applied. These jumps are also seen in ICOADS3.0 observations. In this model, position error at the end of each day increases following a 2D random walk; the latitudinal/longitude errors are reset when a latitude/longitude correction is applied.We fit the variance of the magnitude of latitude/longitude corrections in the observation against model outputs, and estimate that the standard deviation of uncertainty is 5.5 degree for ship course, 32% for ship speed, 22km for latitude correction, and 27km for longitude correction. The estimates here are informative priors for Bayesian methods that quantify position errors of individual tracks.

  20. A simplified analytical dose calculation algorithm accounting for tissue heterogeneity for low-energy brachytherapy sources.

    PubMed

    Mashouf, Shahram; Lechtman, Eli; Beaulieu, Luc; Verhaegen, Frank; Keller, Brian M; Ravi, Ananth; Pignol, Jean-Philippe

    2013-09-21

    The American Association of Physicists in Medicine Task Group No. 43 (AAPM TG-43) formalism is the standard for seeds brachytherapy dose calculation. But for breast seed implants, Monte Carlo simulations reveal large errors due to tissue heterogeneity. Since TG-43 includes several factors to account for source geometry, anisotropy and strength, we propose an additional correction factor, called the inhomogeneity correction factor (ICF), accounting for tissue heterogeneity for Pd-103 brachytherapy. This correction factor is calculated as a function of the media linear attenuation coefficient and mass energy absorption coefficient, and it is independent of the source internal structure. Ultimately the dose in heterogeneous media can be calculated as a product of dose in water as calculated by TG-43 protocol times the ICF. To validate the ICF methodology, dose absorbed in spherical phantoms with large tissue heterogeneities was compared using the TG-43 formalism corrected for heterogeneity versus Monte Carlo simulations. The agreement between Monte Carlo simulations and the ICF method remained within 5% in soft tissues up to several centimeters from a Pd-103 source. Compared to Monte Carlo, the ICF methods can easily be integrated into a clinical treatment planning system and it does not require the detailed internal structure of the source or the photon phase-space.

  1. International water and steam quality standards for thermal power station drum-type and waste heat recovery boilers with the treatment of boiler water with phosphates and NaOH

    NASA Astrophysics Data System (ADS)

    Petrova, T. I.; Orlov, K. A.; Dooley, R. B.

    2017-01-01

    One of the ways for improving the operational reliability and economy of thermal power station equipment, including combined-cycle equipment, is to decrease the rates of the corrosion of constructional materials and the formation of scales in the water-steam circuit. These processes can be reduced to a minimum via the use of water with a minimum content of admixtures and the correction treatment of a heat-transfer fluid. The International Association for the Properties of Water and Steam (IAPWS), which unites specialists from every country of the world, has developed water and steam quality standards for power station equipment of different types on the basis of theoretical studies and long-term experience in the operation of power plants in 21 countries. Different water chemistry regimes are currently used at conventional and combined-cycle thermal power stations. This paper describes the conditions for the implementation of water chemistry regimes with the use of sodium salts of phosphoric acid and NaOH for the quality correction of boiler water. Water and steam quality standards and some recommendations for their maintenance under different operational conditions are given for each of the considered water chemistry regimes. The standards are designed for the water-steam circuit of conventional and combined-cycle thermal power stations. It is pointed out that the quality control of a heat-transfer fluid must be especially careful at combined-cycle thermal power stations with frequent startups and shutdowns.

  2. Summary and synthesis of recommendations of the AmeriFlux Workshop on standardization of flux analysis and diagnostics; Corvallis, Oregon; August 2002

    Treesearch

    W. J. Massman; J. Finnigan; D. Billesbach; S. Miller; A. Black; B. Amiro; B. Law; X. Lee; L. Mahrt; R. Dahlman; T. Foken

    2003-01-01

    A DOE sponsored workshop was held August 27 - 30, 2002 at Oregon State University, Corvallis, Oregon. It was the second of the international AmeriFlux workshops intended to outline and recommend scientifically preferred procedures for calculating and 'correcting' eddy covariance fluxes for all AmeriFlux sites. The fundamental goals of these workshops are (1)...

  3. Time scales in the context of general relativity.

    PubMed

    Guinot, Bernard

    2011-10-28

    Towards 1967, the accuracy of caesium frequency standards reached such a level that the relativistic effect could not be ignored anymore. Corrections began to be applied for the gravitational frequency shift and for distant time comparisons. However, these corrections were not applied to an explicit theoretical framework. Only in 1991 did the International Astronomical Union provide metrics (then improved in 2000) for a definition of space-time coordinates in reference systems centred at the barycentre of the Solar System and at the centre of mass of the Earth. In these systems, the temporal coordinates (coordinate times) can be realized on the basis of one of them, the International Atomic Time (TAI), which is itself a realized time scale. The definition and the role of TAI in this context will be recalled. There remain controversies regarding the name to be given to the unit of coordinate times and to other quantities appearing in the theory. However, the idea that astrometry and celestial mechanics should adopt the usual metrological rules is progressing, together with the use of the International System of Units, among astronomers.

  4. Quality of tuberculosis care in India: a systematic review.

    PubMed

    Satyanarayana, S; Subbaraman, R; Shete, P; Gore, G; Das, J; Cattamanchi, A; Mayer, K; Menzies, D; Harries, A D; Hopewell, P; Pai, M

    2015-07-01

    While Indian studies have assessed care providers' knowledge and practices, there is no systematic review on the quality of tuberculosis (TB) care. We searched multiple sources to identify studies (2000-2014) on providers' knowledge and practices. We used the International Standards for TB Care to benchmark quality of care. Of the 47 studies included, 35 were questionnaire surveys and 12 used chart abstraction. None assessed actual practice using standardised patients. Heterogeneity in the findings precluded meta-analysis. Of 22 studies evaluating provider knowledge about using sputum smears for diagnosis, 10 found that less than half of providers had correct knowledge; 3 of 4 studies assessing self-reported practices by providers found that less than a quarter reported ordering smears for patients with chest symptoms. In 11 of 14 studies that assessed treatment, less than one third of providers knew the standard regimen for drug-susceptible TB. Adherence to standards in practice was generally lower than correct knowledge of those standards. Eleven studies with both public and private providers found higher levels of appropriate knowledge/practice in the public sector. Available evidence suggests suboptimal quality of TB care, particularly in the private sector. Improvement of quality of care should be a priority for India.

  5. Multiple internal standard normalization for improving HS-SPME-GC-MS quantitation in virgin olive oil volatile organic compounds (VOO-VOCs) profile.

    PubMed

    Fortini, Martina; Migliorini, Marzia; Cherubini, Chiara; Cecchi, Lorenzo; Calamai, Luca

    2017-04-01

    The commercial value of virgin olive oils (VOOs) strongly depends on their classification, also based on the aroma of the oils, usually evaluated by a panel test. Nowadays, a reliable analytical method is still needed to evaluate the volatile organic compounds (VOCs) and support the standard panel test method. To date, the use of HS-SPME sampling coupled to GC-MS is generally accepted for the analysis of VOCs in VOOs. However, VOO is a challenging matrix due to the simultaneous presence of: i) compounds at ppm and ppb concentrations; ii) molecules belonging to different chemical classes and iii) analytes with a wide range of molecular mass. Therefore, HS-SPME-GC-MS quantitation based upon the use of external standard method or of only a single internal standard (ISTD) for data normalization in an internal standard method, may be troublesome. In this work a multiple internal standard normalization is proposed to overcome these problems and improving quantitation of VOO-VOCs. As many as 11 ISTDs were used for quantitation of 71 VOCs. For each of them the most suitable ISTD was selected and a good linearity in a wide range of calibration was obtained. Except for E-2-hexenal, without ISTD or with an unsuitable ISTD, the linear range of calibration was narrower with respect to that obtained by a suitable ISTD, confirming the usefulness of multiple internal standard normalization for the correct quantitation of VOCs profile in VOOs. The method was validated for 71 VOCs, and then applied to a series of lampante virgin olive oils and extra virgin olive oils. In light of our results, we propose the application of this analytical approach for routine quantitative analyses and to support sensorial analysis for the evaluation of positive and negative VOOs attributes. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. X-ray fluorescence determination of Sn, Sb, Pb in lead-based bearing alloys using a solution technique

    NASA Astrophysics Data System (ADS)

    Tian, Lunfu; Wang, Lili; Gao, Wei; Weng, Xiaodong; Liu, Jianhui; Zou, Deshuang; Dai, Yichun; Huang, Shuke

    2018-03-01

    For the quantitative analysis of the principal elements in lead-antimony-tin alloys, directly X-ray fluorescence (XRF) method using solid metal disks introduces considerable errors due to the microstructure inhomogeneity. To solve this problem, an aqueous solution XRF method is proposed for determining major amounts of Sb, Sn, Pb in lead-based bearing alloys. The alloy samples were dissolved by a mixture of nitric acid and tartaric acid to eliminated the effects of microstructure of these alloys on the XRF analysis. Rh Compton scattering was used as internal standard for Sb and Sn, and Bi was added as internal standard for Pb, to correct for matrix effects, instrumental and operational variations. High-purity lead, antimony and tin were used to prepare synthetic standards. Using these standards, calibration curves were constructed for the three elements after optimizing the spectrometer parameters. The method has been successfully applied to the analysis of lead-based bearing alloys and is more rapid than classical titration methods normally used. The determination results are consistent with certified values or those obtained by titrations.

  7. Accessibility assessment of assistive technology for the hearing impaired.

    PubMed

    Áfio, Aline Cruz Esmeraldo; Carvalho, Aline Tomaz de; Caravalho, Luciana Vieira de; Silva, Andréa Soares Rocha da; Pagliuca, Lorita Marlena Freitag

    2016-01-01

    to assess the automatic accessibility of assistive technology in online courses for the hearing impaired. evaluation study guided by the Assessment and Maintenance step proposed in the Model of Development of Digital Educational Material. The software Assessor and Simulator for the Accessibility of Sites (ASES) was used to analyze the online course "Education on Sexual and Reproductive Health: the use of condoms" according to the accessibility standards of national and international websites. an error report generated by the program identified, in each didactic module, one error and two warnings related to two international principles and six warnings involved with six national recommendations. The warnings relevant to hearing-impaired people were corrected, and the course was considered accessible by automatic assessment. we concluded that the pages of the course were considered, by the software used, appropriate to the standards of web accessibility.

  8. [Simultaneous determination of delta-9-tetrahydrocannabinol cannabidiol and cannabinol in edible oil using ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Aizhi; Wang, Quanlin; Mo, Shijie

    2010-11-01

    A method for the simultaneous determination of delta-9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in edible oil was developed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with methanol, purified by an LC-Alumina-N solid phase extraction cartridge, separated and detected by the UPLC-MS/MS. Quantitative analysis was corrected by an isotope internal standard method using delta-9-THC-D3 as internal standard. Average recoveries for the target compounds varied from 68.0% to 101.6% with the relative standard deviations ranging from 7.0% to 20.1% at three spiked levels. The limits of detection (LOD) of the method were from 0.06-0.17 microg/kg and the limits of quantification (LOQ) were in the range of 0.20-0.52 microg/kg. The results showed that the method is able to meet the requirements for the simultaneous determination of THC, CBD and CBN in edible oil.

  9. KSC Center Director Bridges accepts an ISO 9001 certificate from DNV

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Center Director Roy Bridges displays the ISO 9001 certificate he was awarded by Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. Dalton Lyon of DNV made the presentation, which included a 2000th ISO Certificate Plaque. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world-class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  10. KSC-98pc907

    NASA Image and Video Library

    1998-08-11

    Center Director Roy Bridges displays the ISO 9001 certificate he was awarded by Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. Dalton Lyon of DNV made the presentation, which included a 2000th ISO Certificate Plaque. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world-class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification

  11. KSC-98pc908

    NASA Image and Video Library

    1998-08-11

    Center Director Roy Bridges (right) displays the 2000th ISO Certificate Plaque he was given by Dalton Lyon (left) of Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. The plaque is a representation of the ISO 9001 certification awarded to KSC by DNV. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already worldclass team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification

  12. Accurate method for luminous transmittance and signal detection quotients measurements in sunglasses lenses

    NASA Astrophysics Data System (ADS)

    Loureiro, A. D.; Gomes, L. M.; Ventura, L.

    2018-02-01

    The international standard ISO 12312-1 proposes transmittance tests that quantify how dark sunglasses lenses are and whether or not they are suitable for driving. To perform these tests a spectrometer is required. In this study, we present and analyze theoretically an accurate alternative method for performing these measurements using simple components. Using three LEDs and a four-channel sensor we generated weighting functions similar to the standard ones for luminous and traffic lights transmittances. From 89 sunglasses lens spectroscopy data, we calculated luminous transmittance and signal detection quotients using our obtained weighting functions and the standard ones. Mean-difference Tukey plots were used to compare the results. All tested sunglasses lenses were classified in the right category and correctly as suitable or not for driving. The greatest absolute errors for luminous transmittance and red, yellow, green and blue signal detection quotients were 0.15%, 0.17, 0.06, 0.04 and 0.18, respectively. This method will be used in a device capable to perform transmittance tests (visible, traffic lights and ultraviolet (UV)) according to the standard. It is important to measure rightly luminous transmittance and relative visual attenuation quotients to report correctly whether or not sunglasses are suitable for driving. Moreover, standard UV requirements depend on luminous transmittance.

  13. Quantitative analysis of synthetic dyes in lipstick by micellar electrokinetic capillary chromatography.

    PubMed

    Desiderio, C; Marra, C; Fanali, S

    1998-06-01

    The separation of synthetic dyes, used as color additives in cosmetics, by micellar electrokinetic capillary chromatography (MEKC) is described in this study. The separation of seven dyes, namely eosine, erythrosine, cyanosine, rhodamine B, orange II, chromotrope FB and tartrazine has been achieved in about 3 min in an untreated fused silica capillary containing as background electrolyte a 25 mM tetraborate/phosphate buffer, pH 8.0, and 30 mM sodium dodecyl sulfate. The electrophoretic method exhibits precision and relatively high sensitivity. A detection limit (LOD, signal/noise = 3) in the range of 5-7.5 X 10(-7) M of standard compounds was recorded. Intra-day repeatability of all the studied dye determinations (8 runs) gave the following results (limit values), % standard deviation: 0.24-1.54% for migration time, 0.99-1.24% for corrected peak areas, 0.99-1.24% for corrected peak area ratio (analyte/internal standard) and 1.56-2.74% for peak areas. The optimized method was successfully applied to the analysis of a lipstick sample where eosine and cyanosine were present.

  14. Patient specific anatomy: the new area of anatomy based on computer science illustrated on liver.

    PubMed

    Soler, Luc; Mutter, Didier; Pessaux, Patrick; Marescaux, Jacques

    2015-01-01

    Over the past century, medical imaging has brought a new revolution: internal anatomy of a patient could be seen without any invasive technique. This revolution has highlighted the two main limits of current anatomy: the anatomical description is physician dependent, and the average anatomy is more and more frequently insufficient to describe anatomical variations. These drawbacks can sometimes be so important that they create mistakes but they can be overcome through the use of 3D patient-specific surgical anatomy. In this article, we propose to illustrate such improvement of standard anatomy on liver. We first propose a general scheme allowing to easily compare the four main liver anatomical descriptions by Takasaki, Goldsmith and Woodburne, Bismuth and Couinaud. From this general scheme we propose four rules to apply in order to correct these initial anatomical definitions. Application of these rules allows to correct usual vascular topological mistakes of standard anatomy. We finally validate such correction on a database of 20 clinical cases compared to the 111 clinical cases of a Couinaud article. Out of the 20 images of the database, we note a revealing difference in 14 cases (70%) on at least one important branch of the portal network. Only six cases (30%) do not present a revealing difference between both labellings. We also show that the right portal fissure location on our 20 cases defined between segment V and VI of our anatomical definition is well correlated with the real position described by Couinaud on 111 cases, knowing that the theoretical position was only found in 46 cases out of 111, i.e., 41.44% of cases with the non-corrected Couinaud definition. We have proposed a new anatomical segmentation of the liver based on four main rules to apply in order to correct topological errors of the four main standard segmentations. Our validation clearly illustrates that this new definition corrects the large amount of mistakes created by the current standard definitions, increased by physician interpretation that can vary from one case to another.

  15. Patient specific anatomy: the new area of anatomy based on computer science illustrated on liver

    PubMed Central

    Mutter, Didier; Pessaux, Patrick; Marescaux, Jacques

    2015-01-01

    Background Over the past century, medical imaging has brought a new revolution: internal anatomy of a patient could be seen without any invasive technique. This revolution has highlighted the two main limits of current anatomy: the anatomical description is physician dependent, and the average anatomy is more and more frequently insufficient to describe anatomical variations. These drawbacks can sometimes be so important that they create mistakes but they can be overcome through the use of 3D patient-specific surgical anatomy. Methods In this article, we propose to illustrate such improvement of standard anatomy on liver. We first propose a general scheme allowing to easily compare the four main liver anatomical descriptions by Takasaki, Goldsmith and Woodburne, Bismuth and Couinaud. From this general scheme we propose four rules to apply in order to correct these initial anatomical definitions. Application of these rules allows to correct usual vascular topological mistakes of standard anatomy. We finally validate such correction on a database of 20 clinical cases compared to the 111 clinical cases of a Couinaud article. Results Out of the 20 images of the database, we note a revealing difference in 14 cases (70%) on at least one important branch of the portal network. Only six cases (30%) do not present a revealing difference between both labellings. We also show that the right portal fissure location on our 20 cases defined between segment V and VI of our anatomical definition is well correlated with the real position described by Couinaud on 111 cases, knowing that the theoretical position was only found in 46 cases out of 111, i.e., 41.44% of cases with the non-corrected Couinaud definition. Conclusions We have proposed a new anatomical segmentation of the liver based on four main rules to apply in order to correct topological errors of the four main standard segmentations. Our validation clearly illustrates that this new definition corrects the large amount of mistakes created by the current standard definitions, increased by physician interpretation that can vary from one case to another. PMID:29075611

  16. A booklet on participants' rights to improve consent for clinical research: a randomized trial.

    PubMed

    Benatar, Jocelyne R; Mortimer, John; Stretton, Matthew; Stewart, Ralph A H

    2012-01-01

    Information on the rights of subjects in clinical trials has become increasingly complex and difficult to understand. This study evaluates whether a simple booklet which is relevant to all research studies improves the understanding of rights needed for subjects to provide informed consent. 21 currently used informed consent forms (ICF) from international clinical trials were separated into information related to the specific research study, and general information on participants' rights. A booklet designed to provide information on participants' rights which used simple language was developed to replace this information in current ICF's Readability of each component of ICF's and the booklet was then assessed using the Flesch-Kincaid Reading ease score (FK). To further evaluate the booklet 282 hospital inpatients were randomised to one of three ways to present research information; a standard ICF, the booklet combined with a short ICF, or the booklet combined with a simplified ICF. Comprehension of information related to the research proposal and to participant's rights was assessed by questionnaire. Information related to participants' rights contributed an average of 44% of the words in standard ICFs, and was harder to read than information describing the clinical trial (FK 25 versus (vs.) 41 respectively, p = 0.0003). The booklet reduced the number of words and improved FK from 25 to 42. The simplified ICF had a slightly higher FK score than the standard ICF (50 vs. 42). Comprehension assessed in inpatients was better for the booklet and short ICF 62%, (95% confidence interval (CI) 56 to 67) correct, or simplified ICF 62% (CI 58 to 68) correct compared to 52%, (CI 47 to 57) correct for the standard ICF, p = 0.009. This was due to better understanding of questions on rights (62% vs. 49% correct, p = 0.0008). Comprehension of study related information was similar for the simplified and standard ICF (60% vs. 64% correct, p = 0.68). A booklet provides a simple consistent approach to providing information on participant rights which is relevant to all research studies, and improves comprehension of patients who typically participate in clinical trials.

  17. A Booklet on Participants’ Rights to Improve Consent for Clinical Research: A Randomized Trial

    PubMed Central

    Benatar, Jocelyne R.; Mortimer, John; Stretton, Matthew; Stewart, Ralph A. H.

    2012-01-01

    Objective Information on the rights of subjects in clinical trials has become increasingly complex and difficult to understand. This study evaluates whether a simple booklet which is relevant to all research studies improves the understanding of rights needed for subjects to provide informed consent. Methods 21 currently used informed consent forms (ICF) from international clinical trials were separated into information related to the specific research study, and general information on participants’ rights. A booklet designed to provide information on participants’ rights which used simple language was developed to replace this information in current ICF’s Readability of each component of ICF’s and the booklet was then assessed using the Flesch-Kincaid Reading ease score (FK). To further evaluate the booklet 282 hospital inpatients were randomised to one of three ways to present research information; a standard ICF, the booklet combined with a short ICF, or the booklet combined with a simplified ICF. Comprehension of information related to the research proposal and to participant’s rights was assessed by questionnaire. Results Information related to participants’ rights contributed an average of 44% of the words in standard ICFs, and was harder to read than information describing the clinical trial (FK 25 versus (vs.) 41 respectively, p = 0.0003). The booklet reduced the number of words and improved FK from 25 to 42. The simplified ICF had a slightly higher FK score than the standard ICF (50 vs. 42). Comprehension assessed in inpatients was better for the booklet and short ICF 62%, (95% confidence interval (CI) 56 to 67) correct, or simplified ICF 62% (CI 58 to 68) correct compared to 52%, (CI 47 to 57) correct for the standard ICF, p = 0.009. This was due to better understanding of questions on rights (62% vs. 49% correct, p = 0.0008). Comprehension of study related information was similar for the simplified and standard ICF (60% vs. 64% correct, p = 0.68). Conclusions A booklet provides a simple consistent approach to providing information on participant rights which is relevant to all research studies, and improves comprehension of patients who typically participate in clinical trials. PMID:23094034

  18. Detection of correct and incorrect measurements in real-time continuous glucose monitoring systems by applying a postprocessing support vector machine.

    PubMed

    Leal, Yenny; Gonzalez-Abril, Luis; Lorencio, Carol; Bondia, Jorge; Vehi, Josep

    2013-07-01

    Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis.

  19. Use of a Deuterated Internal Standard with Pyrolysis-GC/MS Dimeric Marker Analysis to Quantify Tire Tread Particles in the Environment

    PubMed Central

    Unice, Kenneth M.; Kreider, Marisa L.; Panko, Julie M.

    2012-01-01

    Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories. PMID:23202830

  20. Experimental measurements with Monte Carlo corrections and theoretical calculations of neutron inelastic scattering cross section of 115In

    NASA Astrophysics Data System (ADS)

    Wang, Chao; Xiao, Jun; Luo, Xiaobing

    2016-10-01

    The neutron inelastic scattering cross section of 115In has been measured by the activation technique at neutron energies of 2.95, 3.94, and 5.24 MeV with the neutron capture cross sections of 197Au as an internal standard. The effects of multiple scattering and flux attenuation were corrected using the Monte Carlo code GEANT4. Based on the experimental values, the 115In neutron inelastic scattering cross sections data were theoretically calculated between the 1 and 15 MeV with the TALYS software code, the theoretical results of this study are in reasonable agreement with the available experimental results.

  1. Correctional services and prison chaplaincy in Australia: an exploratory study.

    PubMed

    Carey, Lindsay B; Del Medico, Laura

    2014-12-01

    This paper summarizes an exploratory study undertaken to consider the work of Australian chaplaincy personnel ministering to prisoners within correctional facilities. This qualitative research was not concerned with specific correctional institutions per se, but predominantly about the perspectives of chaplains concerning their professional contribution and issues they experienced while trying to provide pastoral care to prisoners. Data from a single-focus group indicated that prison chaplains were striving to fulfill religious and spiritual duties according to national and international standards for the treatment of prisoners. Given various frustrations identified by participants, that either impeded or thwarted their professional role as chaplains, a number of improvements were subsequently identified in order to develop the efficiency and effectiveness of chaplaincy and thus maximize the benefits of pastoral care to prisoners. Implications of this exploratory study relate not only to prison chaplaincy but also to ecclesiastical organizations, correctional facilities, governments and the need of support for further research to be conducted.

  2. [Declarations issued by the International Committee of Medical Journal Editors in conjunction with the Vancouver standards].

    PubMed

    1998-04-01

    These statements, which are published by the International Committee of Medical Journal Editors in conjunction with the Vancouver standards, cover some of the legal, ethical, and practical aspects of the publication of research papers, and of the comments generated by them, in biomedical journals. Following a definition of what constitutes a peer-reviewed journal, the roles of journal owners and editors are described, along with those of members of an editorial board, and procedural norms are set forth in connection with conflicts of interests, retractions or corrections, fraud, and breaches of confidentiality. Among the last topics explored are the problems involved in the dissemination of research results by the popular media, the handling of advertising within the journal, and the simultaneous acceptance of manuscripts whose authors have arrived at opposite conclusions regarding the results of a particular study.

  3. Improved formalism for precision Higgs coupling fits

    NASA Astrophysics Data System (ADS)

    Barklow, Tim; Fujii, Keisuke; Jung, Sunghoon; Karl, Robert; List, Jenny; Ogawa, Tomohisa; Peskin, Michael E.; Tian, Junping

    2018-03-01

    Future e+e- colliders give the promise of model-independent determinations of the couplings of the Higgs boson. In this paper, we present an improved formalism for extracting Higgs boson couplings from e+e- data, based on the effective field theory description of corrections to the Standard Model. We apply this formalism to give projections of Higgs coupling accuracies for stages of the International Linear Collider and for other proposed e+e- colliders.

  4. CARE 3, Version 4 enhancements

    NASA Technical Reports Server (NTRS)

    Bryant, L. A.; Stiffler, J. J.

    1985-01-01

    The enhancements and error corrections to CARE III Version 4 are listed. All changes to Version 4 with the exception of the internal redundancy model were implemented in Version 5. Version 4 is the first public release version for execution on the CDC Cyber 170 series computers. Version 5 is the second release version and it is written in ANSI standard FORTRAN 77 for execution on the DEC VAX 11/700 series computers and many others.

  5. International standards for neurological classification of spinal cord injury: impact of the revised worksheet (revision 02/13) on classification performance.

    PubMed

    Schuld, Christian; Franz, Steffen; Brüggemann, Karin; Heutehaus, Laura; Weidner, Norbert; Kirshblum, Steven C; Rupp, Rüdiger

    2016-09-01

    Prospective cohort study. Comparison of the classification performance between the worksheet revisions of 2011 and 2013 of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI). Ongoing ISNCSCI instructional courses of the European Multicenter Study on Human Spinal Cord Injury (EMSCI). For quality control all participants were requested to classify five ISNCSCI cases directly before (pre-test) and after (post-test) the workshop. One hundred twenty-five clinicians working in 22 SCI centers attended the instructional course between November 2011 and March 2015. Seventy-two clinicians completed the post-test with the 2011 revision of the worksheet and 53 with the 2013 revision. Not applicable. The clinicians' classification performance assessed by the percentage of correctly determined motor levels (ML) and sensory levels, neurological levels of injury (NLI), ASIA Impairment Scales and zones of partial preservations. While no group differences were found in the pre-tests, the overall performance (rev2011: 92.2% ± 6.7%, rev2013: 94.3% ± 7.7%; P = 0.010), the percentage of correct MLs (83.2% ± 14.5% vs. 88.1% ± 15.3%; P = 0.046) and NLIs (86.1% ± 16.7% vs. 90.9% ± 18.6%; P = 0.043) improved significantly in the post-tests. Detailed ML analysis revealed the largest benefit of the 2013 revision (50.0% vs. 67.0%) in a case with a high cervical injury (NLI C2). The results from the EMSCI ISNCSCI post-tests show a significantly better classification performance using the revised 2013 worksheet presumably due to the body-side based grouping of myotomes and dermatomes and their correct horizontal alignment. Even with these proven advantages of the new layout, the correct determination of MLs in the segments C2-C4 remains difficult.

  6. [German version of the math anxiety questionnaire (FRA) for 6- to 9-year-old children].

    PubMed

    Krinzinger, Helga; Kaufmann, Liane; Dowker, Ann; Thomas, Gemma; Graf, Martina; Nuerk, Hans-Christoph; Willmes, Klaus

    2007-09-01

    Is the FRA a reliable and valid instrument? Are there any gender differences concerning math anxiety? Are there any developmental changes in this regard in the course of the early grades? Together with the dyscalculia test TEDI-MATH, the FRA was presented to a total of 450 children from the first to the third grade of primary school (at least 40 girls and 40 boys per semester). The total scale has an internal consistency (Cronbach's alpha) between 0.83 and 0.91. Correlations between arithmetic skills and the FRA scales were mostly significant. The significantly higher negative scores for girls were taken into account by providing standard scores corrected for gender. No systematic developmental changes could be observed. The FRA is the first German math anxiety questionnaire for primary school children. High reliability, standard scores corrected for gender, and economic handling make it an instrument well suited for use in clinical settings (e.g., dyscalculia diagnostics and intervention).

  7. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 18 2011-04-01 2011-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  8. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  9. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 18 2014-04-01 2014-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  10. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 18 2013-04-01 2013-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  11. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 18 2012-04-01 2012-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  12. Quality of tuberculosis care in India: a systematic review

    PubMed Central

    Satyanarayana, S.; Subbaraman, R.; Shete, P.; Gore, G.; Das, J.; Cattamanchi, A.; Mayer, K.; Menzies, D.; Harries, A. D.; Hopewell, P.; Pai, M.

    2015-01-01

    SUMMARY BACKGROUND While Indian studies have assessed care providers’ knowledge and practices, there is no systematic review on the quality of tuberculosis (TB) care. METHODS We searched multiple sources to identify studies (2000–2014) on providers’ knowledge and practices. We used the International Standards for TB Care to benchmark quality of care. RESULTS Of the 47 studies included, 35 were questionnaire surveys and 12 used chart abstraction. None assessed actual practice using standardised patients. Heterogeneity in the findings precluded meta-analysis. Of 22 studies evaluating provider knowledge about using sputum smears for diagnosis, 10 found that less than half of providers had correct knowledge; 3 of 4 studies assessing self-reported practices by providers found that less than a quarter reported ordering smears for patients with chest symptoms. In 11 of 14 studies that assessed treatment, less than one third of providers knew the standard regimen for drug-susceptible TB. Adherence to standards in practice was generally lower than correct knowledge of those standards. Eleven studies with both public and private providers found higher levels of appropriate knowledge/practice in the public sector. CONCLUSIONS Available evidence suggests suboptimal quality of TB care, particularly in the private sector. Improvement of quality of care should be a priority for India. PMID:26056098

  13. An Internationally Consented Standard for Nursing Process-Clinical Decision Support Systems in Electronic Health Records.

    PubMed

    Müller-Staub, Maria; de Graaf-Waar, Helen; Paans, Wolter

    2016-11-01

    Nurses are accountable to apply the nursing process, which is key for patient care: It is a problem-solving process providing the structure for care plans and documentation. The state-of-the art nursing process is based on classifications that contain standardized concepts, and therefore, it is named Advanced Nursing Process. It contains valid assessments, nursing diagnoses, interventions, and nursing-sensitive patient outcomes. Electronic decision support systems can assist nurses to apply the Advanced Nursing Process. However, nursing decision support systems are missing, and no "gold standard" is available. The study aim is to develop a valid Nursing Process-Clinical Decision Support System Standard to guide future developments of clinical decision support systems. In a multistep approach, a Nursing Process-Clinical Decision Support System Standard with 28 criteria was developed. After pilot testing (N = 29 nurses), the criteria were reduced to 25. The Nursing Process-Clinical Decision Support System Standard was then presented to eight internationally known experts, who performed qualitative interviews according to Mayring. Fourteen categories demonstrate expert consensus on the Nursing Process-Clinical Decision Support System Standard and its content validity. All experts agreed the Advanced Nursing Process should be the centerpiece for the Nursing Process-Clinical Decision Support System and should suggest research-based, predefined nursing diagnoses and correct linkages between diagnoses, evidence-based interventions, and patient outcomes.

  14. Development of a Postcolumn Infused-Internal Standard Liquid Chromatography Mass Spectrometry Method for Quantitative Metabolomics Studies.

    PubMed

    Liao, Hsiao-Wei; Chen, Guan-Yuan; Wu, Ming-Shiang; Liao, Wei-Chih; Lin, Ching-Hung; Kuo, Ching-Hua

    2017-02-03

    Quantitative metabolomics has become much more important in clinical research in recent years. Individual differences in matrix effects (MEs) and the injection order effect are two major factors that reduce the quantification accuracy in liquid chromatography-electrospray ionization-mass spectrometry-based (LC-ESI-MS) metabolomics studies. This study proposed a postcolumn infused-internal standard (PCI-IS) combined with a matrix normalization factor (MNF) strategy to improve the analytical accuracy of quantitative metabolomics. The PCI-IS combined with the MNF method was applied for a targeted metabolomics study of amino acids (AAs). D8-Phenylalanine was used as the PCI-IS, and it was postcolumn-infused into the ESI interface for calibration purposes. The MNF was used to bridge the AA response in a standard solution with the plasma samples. The MEs caused signal changes that were corrected by dividing the AA signal intensities by the PCI-IS intensities after adjustment with the MNF. After the method validation, we evaluated the method applicability for breast cancer research using 100 plasma samples. The quantification results revealed that the 11 tested AAs exhibit an accuracy between 88.2 and 110.7%. The principal component analysis score plot revealed that the injection order effect can be successfully removed, and most of the within-group variation of the tested AAs decreased after the PCI-IS correction. Finally, targeted metabolomics studies on the AAs showed that tryptophan was expressed more in malignant patients than in the benign group. We anticipate that a similar approach can be applied to other endogenous metabolites to facilitate quantitative metabolomics studies.

  15. Computer decision support as a source of interpretation error: the case of electrocardiograms.

    PubMed

    Tsai, Theodore L; Fridsma, Douglas B; Gatti, Guido

    2003-01-01

    The aim of this study was to determine the effect that the computer interpretation (CI) of electrocardiograms (EKGs) has on the accuracy of resident (noncardiologist) physicians reading EKGs. A randomized, controlled trial was conducted in a laboratory setting from February through June 2001, using a two-period crossover design with matched pairs of subjects randomly assigned to sequencing groups. Subjects' interpretive accuracy of discrete, cardiologist-determined EKG findings were measured as judged by a board-certified internist. Without the CI, subjects interpreted 48.9% (95% confidence interval, 45.0% to 52.8%) of the findings correctly. With the CI, subjects interpreted 55.4% (51.9% to 58.9%) correctly (p < 0.0001). When the CIs that agreed with the gold standard (Correct CIs) were not included, 53.1% (47.7% to 58.5%) of the findings were interpreted correctly. When the correct CI was included, accuracy increased to 68.1% (63.2% to 72.7%; p < 0.0001). When computer advice that did not agree with the gold standard (Incorrect CI) was not provided to the subjects, 56.7% (48.5% to 64.5%) of findings were interpreted correctly. Accuracy dropped to 48.3% (40.4% to 56.4%) when the incorrect computer advice was provided (p = 0.131). Subjects erroneously agreed with the incorrect CI more often when it was presented with the EKG 67.7% (57.2% to 76.7%) than when it was not 34.6% (23.8% to 47.3%; p < 0.0001). Computer decision support systems can generally improve the interpretive accuracy of internal medicine residents in reading EKGs. However, subjects were influenced significantly by incorrect advice, which tempers the overall usefulness of computer-generated advice in this and perhaps other areas.

  16. Computer Decision Support as a Source of Interpretation Error: The Case of Electrocardiograms

    PubMed Central

    Tsai, Theodore L.; Fridsma, Douglas B.; Gatti, Guido

    2003-01-01

    Objective: The aim of this study was to determine the effect that the computer interpretation (CI) of electrocardiograms (EKGs) has on the accuracy of resident (noncardiologist) physicians reading EKGs. Design: A randomized, controlled trial was conducted in a laboratory setting from February through June 2001, using a two-period crossover design with matched pairs of subjects randomly assigned to sequencing groups. Measurements: Subjects' interpretive accuracy of discrete, cardiologist-determined EKG findings were measured as judged by a board-certified internist. Results: Without the CI, subjects interpreted 48.9% (95% confidence interval, 45.0% to 52.8%) of the findings correctly. With the CI, subjects interpreted 55.4% (51.9% to 58.9%) correctly (p < 0.0001). When the CIs that agreed with the gold standard (Correct CIs) were not included, 53.1% (47.7% to 58.5%) of the findings were interpreted correctly. When the correct CI was included, accuracy increased to 68.1% (63.2% to 72.7%; p < 0.0001). When computer advice that did not agree with the gold standard (Incorrect CI) was not provided to the subjects, 56.7% (48.5% to 64.5%) of findings were interpreted correctly. Accuracy dropped to 48.3% (40.4% to 56.4%) when the incorrect computer advice was provided (p = 0.131). Subjects erroneously agreed with the incorrect CI more often when it was presented with the EKG 67.7% (57.2% to 76.7%) than when it was not 34.6% (23.8% to 47.3%; p < 0.0001). Conclusions: Computer decision support systems can generally improve the interpretive accuracy of internal medicine residents in reading EKGs. However, subjects were influenced significantly by incorrect advice, which tempers the overall usefulness of computer-generated advice in this and perhaps other areas. PMID:12807810

  17. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  18. iMet-Q: A User-Friendly Tool for Label-Free Metabolomics Quantitation Using Dynamic Peak-Width Determination

    PubMed Central

    Chang, Hui-Yin; Chen, Ching-Tai; Lih, T. Mamie; Lynn, Ke-Shiuan; Juo, Chiun-Gung; Hsu, Wen-Lian; Sung, Ting-Yi

    2016-01-01

    Efficient and accurate quantitation of metabolites from LC-MS data has become an important topic. Here we present an automated tool, called iMet-Q (intelligent Metabolomic Quantitation), for label-free metabolomics quantitation from high-throughput MS1 data. By performing peak detection and peak alignment, iMet-Q provides a summary of quantitation results and reports ion abundance at both replicate level and sample level. Furthermore, it gives the charge states and isotope ratios of detected metabolite peaks to facilitate metabolite identification. An in-house standard mixture and a public Arabidopsis metabolome data set were analyzed by iMet-Q. Three public quantitation tools, including XCMS, MetAlign, and MZmine 2, were used for performance comparison. From the mixture data set, seven standard metabolites were detected by the four quantitation tools, for which iMet-Q had a smaller quantitation error of 12% in both profile and centroid data sets. Our tool also correctly determined the charge states of seven standard metabolites. By searching the mass values for those standard metabolites against Human Metabolome Database, we obtained a total of 183 metabolite candidates. With the isotope ratios calculated by iMet-Q, 49% (89 out of 183) metabolite candidates were filtered out. From the public Arabidopsis data set reported with two internal standards and 167 elucidated metabolites, iMet-Q detected all of the peaks corresponding to the internal standards and 167 metabolites. Meanwhile, our tool had small abundance variation (≤0.19) when quantifying the two internal standards and had higher abundance correlation (≥0.92) when quantifying the 167 metabolites. iMet-Q provides user-friendly interfaces and is publicly available for download at http://ms.iis.sinica.edu.tw/comics/Software_iMet-Q.html. PMID:26784691

  19. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  20. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  1. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  2. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  3. UHPLC-MS/MS method for the quantitation of penicillin G and metabolites in citrus fruit using internal standards.

    PubMed

    Canzani, Daniele; Hsieh, Kevin; Standland, Matthew; Hammack, Walter; Aldeek, Fadi

    2017-02-15

    Penicillin G has been applied to citrus trees as a potential treatment in the fight against Huanglongbing (HLB). Here, we have developed and validated a method to identify and quantitate penicillin G and two of its metabolites, penillic acid and penilloic acid, in citrus fruit using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). This method improves upon a previous method by incorporating isotopically labeled internal standards, namely, penillic acid-D 5 , and penilloic acid-D 5 . These standards greatly enhanced the accuracy and precision of our measurements by compensating for recovery losses, degradation, and matrix effects. When 2g of citrus fruit sample is extracted, the limits of detection (LOD) were determined to be 0.1ng/g for penicillin G and penilloic acid, and 0.25ng/g for penillic acid. At fortification levels of 0.1, 0.25, 1, and 10ng/g, absolute recoveries for penillic and penilloic acids were generally between 50-70%. Recoveries corrected with the isotopically labeled standards were approximately 90-110%. This method will be useful for the identification and quantitation of drug residues and their degradation products using isotopically labeled standards and UHPLC-MS/MS. Published by Elsevier B.V.

  4. KSC Center Director Bridges accepts an ISO 9001 certification plaque from DNV

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Center Director Roy Bridges (right) displays the 2000th ISO Certificate Plaque he was given by Dalton Lyon (left) of Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. The plaque is a representation of the ISO 9001 certification awarded to KSC by DNV. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  5. KSC-98pc909

    NASA Image and Video Library

    1998-08-11

    Center Director Roy Bridges speaks to KSC employees at the ISO certification ceremony held at the Training Auditorium. Bridges was presented an ISO 9001 certificate and plaque awarded to KSC by Det Norske Veritas (DNV), Inc., an international ISO certification organization. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already worldclass team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification. Next to Bridges is Heidi Hollingsworth, with the Center for Independent Living, who uses American Sign Language for any hearing-impaired employees in the audience

  6. Coded Modulation in C and MATLAB

    NASA Technical Reports Server (NTRS)

    Hamkins, Jon; Andrews, Kenneth S.

    2011-01-01

    This software, written separately in C and MATLAB as stand-alone packages with equivalent functionality, implements encoders and decoders for a set of nine error-correcting codes and modulators and demodulators for five modulation types. The software can be used as a single program to simulate the performance of such coded modulation. The error-correcting codes implemented are the nine accumulate repeat-4 jagged accumulate (AR4JA) low-density parity-check (LDPC) codes, which have been approved for international standardization by the Consultative Committee for Space Data Systems, and which are scheduled to fly on a series of NASA missions in the Constellation Program. The software implements the encoder and decoder functions, and contains compressed versions of generator and parity-check matrices used in these operations.

  7. Calibration procedure for a laser triangulation scanner with uncertainty evaluation

    NASA Astrophysics Data System (ADS)

    Genta, Gianfranco; Minetola, Paolo; Barbato, Giulio

    2016-11-01

    Most of low cost 3D scanning devices that are nowadays available on the market are sold without a user calibration procedure to correct measurement errors related to changes in environmental conditions. In addition, there is no specific international standard defining a procedure to check the performance of a 3D scanner along time. This paper aims at detailing a thorough methodology to calibrate a 3D scanner and assess its measurement uncertainty. The proposed procedure is based on the use of a reference ball plate and applied to a triangulation laser scanner. Experimental results show that the metrological performance of the instrument can be greatly improved by the application of the calibration procedure that corrects systematic errors and reduces the device's measurement uncertainty.

  8. 75 FR 34527 - Volkswagen Petition for Exemption From the Vehicle Theft Prevention Standard; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-17

    ... for Exemption From the Vehicle Theft Prevention Standard; Correction AGENCY: National Highway Traffic... the Theft Prevention Standard. This document corrects the model year of the new Volkswagen vehicle... 543, Exemption from the Theft Prevention Standard. This petition is granted because the agency has...

  9. 76 FR 8699 - Locomotive Safety Standards; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    .... FRA-2009-0094 and FRA-2009-0095, Notice No. 2] RIN 2130-AC16 Locomotive Safety Standards; Correction... notifying the public that the correct docket number for the Locomotive Safety Standards notice of proposed... locomotive safety standards. See 76 FR 2200. The NPRM established a public docket to receive comments in...

  10. 77 FR 23159 - Locomotive Safety Standards; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    .... FRA-2009-0094 and FR-2009-0095, Notice No. 4] RIN 2130-AC16 Locomotive Safety Standards; Correction... notifying the public that the correct docket number for the Locomotive Safety Standards final rule is FRA... rule related to locomotive safety standards. See 77 FR 21312. The final rule established a public...

  11. Improved formalism for precision Higgs coupling fits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barklow, Tim; Fujii, Keisuke; Jung, Sunghoon

    Future e +e – colliders give the promise of model-independent determinations of the couplings of the Higgs boson. In this paper, we present an improved formalism for extracting Higgs boson couplings from e +e – data, based on the effective field theory description of corrections to the Standard Model. Lastly, we apply this formalism to give projections of Higgs coupling accuracies for stages of the International Linear Collider and for other proposed e +e – colliders.

  12. Improved formalism for precision Higgs coupling fits

    DOE PAGES

    Barklow, Tim; Fujii, Keisuke; Jung, Sunghoon; ...

    2018-03-20

    Future e +e – colliders give the promise of model-independent determinations of the couplings of the Higgs boson. In this paper, we present an improved formalism for extracting Higgs boson couplings from e +e – data, based on the effective field theory description of corrections to the Standard Model. Lastly, we apply this formalism to give projections of Higgs coupling accuracies for stages of the International Linear Collider and for other proposed e +e – colliders.

  13. Isotope pattern deconvolution as a tool to study iron metabolism in plants.

    PubMed

    Rodríguez-Castrillón, José Angel; Moldovan, Mariella; García Alonso, J Ignacio; Lucena, Juan José; García-Tomé, Maria Luisa; Hernández-Apaolaza, Lourdes

    2008-01-01

    Isotope pattern deconvolution is a mathematical technique for isolating distinct isotope signatures from mixtures of natural abundance and enriched tracers. In iron metabolism studies measurement of all four isotopes of the element by high-resolution multicollector or collision cell ICP-MS allows the determination of the tracer/tracee ratio with simultaneous internal mass bias correction and lower uncertainties. This technique was applied here for the first time to study iron uptake by cucumber plants using 57Fe-enriched iron chelates of the o,o and o,p isomers of ethylenediaminedi(o-hydroxyphenylacetic) acid (EDDHA) and ethylenediamine tetraacetic acid (EDTA). Samples of root, stem, leaves, and xylem sap, after exposure of the cucumber plants to the mentioned 57Fe chelates, were collected, dried, and digested using nitric acid. The isotopic composition of iron in the samples was measured by ICP-MS using a high-resolution multicollector instrument. Mass bias correction was computed using both a natural abundance iron standard and by internal correction using isotope pattern deconvolution. It was observed that, for plants with low 57Fe enrichment, isotope pattern deconvolution provided lower tracer/tracee ratio uncertainties than the traditional method applying external mass bias correction. The total amount of the element in the plants was determined by isotope dilution analysis, using a collision cell quadrupole ICP-MS instrument, after addition of 57Fe or natural abundance Fe in a known amount which depended on the isotopic composition of the sample.

  14. Detection of lithium in the cool halo dwarfs Groombridge 1830 and HD 134439: Implications for internal stellar mixing and cosmology

    NASA Technical Reports Server (NTRS)

    Deliyannis, Constantine P.; Ryan, Sean G.; Beers, Timothy C.; Thorburn, Julie A.

    1994-01-01

    Lithium abundances in halo stars, when interpreted correctly, hold the key to uncovering the primordial Li abundance Li(sub p). However, whereas standard stellar evolutionary models imply consistency in standard big bang nucleosynthesis (BBN), models with rotationally induced mixing imply a higher Li(sub p), possibly implying an inconsistency in standard BBN. We report here Li detections in two cool halo dwarfs, Gmb 1830 and HD 134439. These are the coolest and lowest Li detections in halo dwarfs to date, and are consistent with the metallicity dependence of Li depletion in published models. If the recent report of a beryllium deficiency in Gmb 1830 represents a real Be depletion, then the rotational models would be favored. We propose tests to reduce critical uncertainties.

  15. Ovarian Cancer Incidence Corrected for Oophorectomy

    PubMed Central

    Baldwin, Lauren A.; Chen, Quan; Tucker, Thomas C.; White, Connie G.; Ore, Robert N.; Huang, Bin

    2017-01-01

    Current reported incidence rates for ovarian cancer may significantly underestimate the true rate because of the inclusion of women in the calculations who are not at risk for ovarian cancer due to prior benign salpingo-oophorectomy (SO). We have considered prior SO to more realistically estimate risk for ovarian cancer. Kentucky Health Claims Data, International Classification of Disease 9 (ICD-9) codes, Current Procedure Terminology (CPT) codes, and Kentucky Behavioral Risk Factor Surveillance System (BRFSS) Data were used to identify women who have undergone SO in Kentucky, and these women were removed from the at-risk pool in order to re-assess incidence rates to more accurately represent ovarian cancer risk. The protective effect of SO on the population was determined on an annual basis for ages 5–80+ using data from the years 2009–2013. The corrected age-adjusted rates of ovarian cancer that considered SO ranged from 33% to 67% higher than age-adjusted rates from the standard population. Correction of incidence rates for ovarian cancer by accounting for women with prior SO gives a better understanding of risk for this disease faced by women. The rates of ovarian cancer were substantially higher when SO was taken into consideration than estimates from the standard population. PMID:28368298

  16. Internal tide generation by abyssal hills using analytical theory

    NASA Astrophysics Data System (ADS)

    Melet, Angélique; Nikurashin, Maxim; Muller, Caroline; Falahat, S.; Nycander, Jonas; Timko, Patrick G.; Arbic, Brian K.; Goff, John A.

    2013-11-01

    Internal tide driven mixing plays a key role in sustaining the deep ocean stratification and meridional overturning circulation. Internal tides can be generated by topographic horizontal scales ranging from hundreds of meters to tens of kilometers. State of the art topographic products barely resolve scales smaller than ˜10 km in the deep ocean. On these scales abyssal hills dominate ocean floor roughness. The impact of abyssal hill roughness on internal-tide generation is evaluated in this study. The conversion of M2 barotropic to baroclinic tidal energy is calculated based on linear wave theory both in real and spectral space using the Shuttle Radar Topography Mission SRTM30_PLUS bathymetric product at 1/120° resolution with and without the addition of synthetic abyssal hill roughness. Internal tide generation by abyssal hills integrates to 0.1 TW globally or 0.03 TW when the energy flux is empirically corrected for supercritical slope (i.e., ˜10% of the energy flux due to larger topographic scales resolved in standard products in both cases). The abyssal hill driven energy conversion is dominated by mid-ocean ridges, where abyssal hill roughness is large. Focusing on two regions located over the Mid-Atlantic Ridge and the East Pacific Rise, it is shown that regionally linear theory predicts an increase of the energy flux due to abyssal hills of up to 100% or 60% when an empirical correction for supercritical slopes is attempted. Therefore, abyssal hills, unresolved in state of the art topographic products, can have a strong impact on internal tide generation, especially over mid-ocean ridges.

  17. Transfer of simulated lumbar puncture training to the clinical setting.

    PubMed

    White, Marjorie L; Jones, Rachel; Zinkan, Lynn; Tofil, Nancy M

    2012-10-01

    To show that with a combination of evidence-based didactic and hands-on skill demonstration, pediatric interns will be able to correctly perform lumbar punctures (LPs) on neonates in the actual clinical setting. Twenty-three pediatric and internal medicine/pediatric first year residents attended a 1-hour course during their orientation. The course consisted of an evidence-based presentation, reviewing anatomy, indications, complications, and techniques for performing LPs, including a video presentation, followed by hands-on practice of LPs. All interns were anonymously surveyed preintervention and postintervention. The survey results were compared for each learner. After the intervention, interns were individually assessed by a single investigator using a standardized checklist during an LP of an actual pediatric patient during their first year of residency. Pretest and posttest knowledge improved by approximately 12% (P < 0.05). Preintervention confidence and experience were low among learners. Twenty-one of 23 interns completed a follow-up assessment of an LP on an actual pediatric patient. The average on the assessment was 9.7 ± 1.1 of 11 (88% ± 10%). The average number of LP attempts was 1.4 ± 0.5. The steps most frequently missed were preparing the supplies and performing the LP with the bevel of the needle parallel to the spinal ligament, with only 48% of interns performing each of these steps correctly. A task trainer-based course improved the confidence and knowledge about an important pediatric procedure. This confidence and knowledge can translate to actual clinical practice. Further investigations are necessary to support this knowledge and skill translation.

  18. 77 FR 4582 - Certain Mobile Devices and Related Software Corrected Notice of Request for Statements on the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-750] Certain Mobile Devices and Related Software Corrected Notice of Request for Statements on the Public Interest AGENCY: U.S. International Trade Commission. ACTION: Correction to Notice. SUMMARY: This Notice corrects the notice in the same matter...

  19. International recommendation for a comprehensive neuropathologic workup of epilepsy surgery brain tissue: A consensus Task Force report from the ILAE Commission on Diagnostic Methods.

    PubMed

    Blümcke, Ingmar; Aronica, Eleonora; Miyata, Hajime; Sarnat, Harvey B; Thom, Maria; Roessler, Karl; Rydenhag, Bertil; Jehi, Lara; Krsek, Pavel; Wiebe, Samuel; Spreafico, Roberto

    2016-03-01

    Epilepsy surgery is an effective treatment in many patients with drug-resistant focal epilepsies. An early decision for surgical therapy is facilitated by a magnetic resonance imaging (MRI)-visible brain lesion congruent with the electrophysiologically abnormal brain region. Recent advances in the pathologic diagnosis and classification of epileptogenic brain lesions are helpful for clinical correlation, outcome stratification, and patient management. However, application of international consensus classification systems to common epileptic pathologies (e.g., focal cortical dysplasia [FCD] and hippocampal sclerosis [HS]) necessitates standardized protocols for neuropathologic workup of epilepsy surgery specimens. To this end, the Task Force of Neuropathology from the International League Against Epilepsy (ILAE) Commission on Diagnostic Methods developed a consensus standard operational procedure for tissue inspection, distribution, and processing. The aims are to provide a systematic framework for histopathologic workup, meeting minimal standards and maximizing current and future opportunities for morphofunctional correlations and molecular studies for both clinical care and research. Whenever feasible, anatomically intact surgical specimens are desirable to enable systematic analysis in selective hippocampectomies, temporal lobe resections, and lesional or nonlesional neocortical samples. Correct orientation of sample and the sample's relation to neurophysiologically aberrant sites requires good communication between pathology and neurosurgical teams. Systematic tissue sampling of 5-mm slabs along a defined anatomic axis and application of a limited immunohistochemical panel will ensure a reliable differential diagnosis of main pathologies encountered in epilepsy surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  20. Calibration of the NPL secondary standard radionuclide calibrator for 32P, 89Sr and 90Y

    NASA Astrophysics Data System (ADS)

    Woods, M. J.; Munster, A. S.; Sephton, J. P.; Lucas, S. E. M.; Walsh, C. Paton

    1996-02-01

    Pure beta particle emitting radionuclides have many therapeutic applications in nuclear medicine. The response of the NPL secondary standard radionuclide calibrator to 32P, 89Sr and 90Y has been measured using accurately calibrated solutions. For this purpose, high efficiency solid sources were prepared gravimetrically from dilute solutions of each radionuclide and assayed in a 4π proportional counter; the source activities were determined using known detection efficiency factors. Measurements were made of the current response (pA/MBq) of the NPL secondary standard radionuclide calibrator using the original concentrated solutions. Calibration figures have been derived for 2 and 5 ml British Standard glass ampoules and Amersham International plc P6 vials. Volume correction factors have also been determined. Gamma-ray emitting contaminants can have a disproportionate effect on the calibrator response and particular attention has been paid to this.

  1. The new agreement of the international RIGA consensus conference on nasal airway function tests.

    PubMed

    Vogt, K; Bachmann-Harildstad, G; Lintermann, A; Nechyporenko, A; Peters, F; Wernecke, K D

    2018-01-21

    The report reflects an agreement based on the consensus conference of the International Standardization Committee on the Objective Assessment of the Nasal Airway in Riga, 2nd Nov. 2016. The aim of the conference was to address the existing nasal airway function tests and to take into account physical, mathematical and technical correctness as a base of international standardization as well as the requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices. Rhinomanometry, acoustic rhinometry, peak nasal inspiratory flow, Odiosoft-Rhino, optical rhinometry, 24-h measurements, computational fluid dynamics, nasometry and the mirrow test were evaluated for important diagnostic criteria, which are the precision of the equipment including calibration and the software applied; validity with sensitivity, specificity, positive and negative predictive values, reliability with intra-individual and inter-individual reproducibility and responsiveness in clinical studies. For rhinomanometry, the logarithmic effective resistance was set as the parameter of high diagnostic relevance. In acoustic rhinometry, the area of interest for the minimal cross-sectional area will need further standardization. Peak nasal inspiratory flow is a reproducible and fast test, which showed a high range of mean values in different studies. The state of the art with computational fluid dynamics for the simulation of the airway still depends on high performance computing hardware and will, after standardization of the software and both the software and hardware for imaging protocols, certainly deliver a better understanding of the nasal airway flux.

  2. Harmonizing Landsat and Sentinel-2 Reflectances for Better Land Monitoring

    NASA Technical Reports Server (NTRS)

    Masek, Jeffrey; Vermote, Eric; Franch, Belen; Roger, Jean-Claude; Skakun, Sergii; Claverie, Martin; Dungan, Jennifer

    2016-01-01

    When combined, Landsat and ESA Sentinel-2 observations can provide 2-4 day coverage for the global land area. A collaboration among NASA GSFC (Goddard Space Flight Center), University of Maryland, and NASA Ames has developed a processing chain to create seamless, "harmonized" reflectance products using standardized atmospheric correction, BRDF (Bidirectional Reflectance Distribution Function) adjustment, spectral bandpass adjustment, and gridding algorithms. These products point the way to a "30-m MODIS (Moderate Resolution Imaging Spectroradiometer)" capability for agricultural and ecosystem monitoring by leveraging international sensors.

  3. Yearbook of Correctional Education, 1998-1999.

    ERIC Educational Resources Information Center

    Karcz, Stan A., Ed.; Wilderson, Frank B., Jr., Ed.

    This document contains five monographs on correctional education in the United States and internationally. "Towards a Renaissance of Prison Education: International Preconference Symposium" (Carolyn Eggleston, Alice Tracy) reports on a joint symposium of the Correctional Education Association and the European Prison Education Association…

  4. 75 FR 34526 - Ford Petition for Exemption From the Vehicle Theft Prevention Standard; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-17

    ... DEPARTMENT OF TRANSPORTATION National Highway Traffic Safety Administration Ford Petition for Exemption From the Vehicle Theft Prevention Standard; Correction AGENCY: National Highway Traffic Safety... accordance with 49 CFR part 543, Exemption from the Theft Prevention Standard. This document corrects certain...

  5. 40 CFR 1066.605 - Mass-based and molar-based exhaust emission calculations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the test interval, corrected to standard temperature and pressure. m PMfil = mass of particulate... = stabilized, ht = hot transient), corrected to standard reference conditions. m PMfil = mass of particulate... stabilized), corrected to standard reference conditions. m PMfil = mass of particulate matter emissions on...

  6. Quantification of fructo-oligosaccharides based on the evaluation of oligomer ratios using an artificial neural network.

    PubMed

    Onofrejová, Lucia; Farková, Marta; Preisler, Jan

    2009-04-13

    The application of an internal standard in quantitative analysis is desirable in order to correct for variations in sample preparation and instrumental response. In mass spectrometry of organic compounds, the internal standard is preferably labelled with a stable isotope, such as (18)O, (15)N or (13)C. In this study, a method for the quantification of fructo-oligosaccharides using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI TOF MS) was proposed and tested on raftilose, a partially hydrolysed inulin with a degree of polymeration 2-7. A tetraoligosaccharide nystose, which is chemically identical to the raftilose tetramer, was used as an internal standard rather than an isotope-labelled analyte. Two mathematical approaches used for data processing, conventional calculations and artificial neural networks (ANN), were compared. The conventional data processing relies on the assumption that a constant oligomer dispersion profile will change after the addition of the internal standard and some simple numerical calculations. On the other hand, ANN was found to compensate for a non-linear MALDI response and variations in the oligomer dispersion profile with raftilose concentration. As a result, the application of ANN led to lower quantification errors and excellent day-to-day repeatability compared to the conventional data analysis. The developed method is feasible for MS quantification of raftilose in the range of 10-750 pg with errors below 7%. The content of raftilose was determined in dietary cream; application can be extended to other similar polymers. It should be stressed that no special optimisation of the MALDI process was carried out. A common MALDI matrix and sample preparation were used and only the basic parameters, such as sampling and laser energy, were optimised prior to quantification.

  7. Seismic reflection imaging, accounting for primary and multiple reflections

    NASA Astrophysics Data System (ADS)

    Wapenaar, Kees; van der Neut, Joost; Thorbecke, Jan; Broggini, Filippo; Slob, Evert; Snieder, Roel

    2015-04-01

    Imaging of seismic reflection data is usually based on the assumption that the seismic response consists of primary reflections only. Multiple reflections, i.e. waves that have reflected more than once, are treated as primaries and are imaged at wrong positions. There are two classes of multiple reflections, which we will call surface-related multiples and internal multiples. Surface-related multiples are those multiples that contain at least one reflection at the earth's surface, whereas internal multiples consist of waves that have reflected only at subsurface interfaces. Surface-related multiples are the strongest, but also relatively easy to deal with because the reflecting boundary (the earth's surface) is known. Internal multiples constitute a much more difficult problem for seismic imaging, because the positions and properties of the reflecting interfaces are not known. We are developing reflection imaging methodology which deals with internal multiples. Starting with the Marchenko equation for 1D inverse scattering problems, we derived 3D Marchenko-type equations, which relate reflection data at the surface to Green's functions between virtual sources anywhere in the subsurface and receivers at the surface. Based on these equations, we derived an iterative scheme by which these Green's functions can be retrieved from the reflection data at the surface. This iterative scheme requires an estimate of the direct wave of the Green's functions in a background medium. Note that this is precisely the same information that is also required by standard reflection imaging schemes. However, unlike in standard imaging, our iterative Marchenko scheme retrieves the multiple reflections of the Green's functions from the reflection data at the surface. For this, no knowledge of the positions and properties of the reflecting interfaces is required. Once the full Green's functions are retrieved, reflection imaging can be carried out by which the primaries and multiples are mapped to their correct positions, with correct reflection amplitudes. In the presentation we will illustrate this new methodology with numerical examples and discuss its potential and limitations.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shadid, John Nicolas; Fish, Jacob; Waisman, Haim

    Two heuristic strategies intended to enhance the performance of the generalized global basis (GGB) method [H. Waisman, J. Fish, R.S. Tuminaro, J. Shadid, The Generalized Global Basis (GGB) method, International Journal for Numerical Methods in Engineering 61(8), 1243-1269] applied to nonlinear systems are presented. The standard GGB accelerates a multigrid scheme by an additional coarse grid correction that filters out slowly converging modes. This correction requires a potentially costly eigen calculation. This paper considers reusing previously computed eigenspace information. The GGB? scheme enriches the prolongation operator with new eigenvectors while the modified method (MGGB) selectively reuses the same prolongation. Bothmore » methods use the criteria of principal angles between subspaces spanned between the previous and current prolongation operators. Numerical examples clearly indicate significant time savings in particular for the MGGB scheme.« less

  9. International Organization of Standardization (ISO) and Cambridge Filter Test (CFT) Smoking Regimen Data Comparisons in Tobacco Product Marketing Applications.

    PubMed

    Chae, Changyu; Walters, Matthew J; Holman, Matthew R

    2017-07-01

    We investigated the differences in TNCO (tar, nicotine, and carbon monoxide) smoke yields generated under the International Organization of Standardization (ISO) and Federal Trade Commission (FTC) Cambridge Filter Test (CFT) smoking regimens. Twenty-nine commercial cigarette products from the US marketplace were acquired in 2015 and tested by measuring the TNCO smoke yields generated under these 2 nonintense smoking regimens. Data obtained demonstrated a linear relationship between the TNCO yields produced under the 2 smoking regimens (R 2 > 0.99). TNCO yields produced by each product were higher under the CFT smoking regimen than the ISO smoking regimen. We found that tar, nicotine, and carbon monoxide yields were consistently 10% to 13% higher under the CFT smoking regimen than under the ISO smoking regimen. This strong correlation indicates that the 2 smoking regimens can be used to apply a correlation correction to CFT TNCO data and allow its comparison to ISO TNCO data in tobacco product marketing applications.

  10. New Method for the Approximation of Corrected Calcium Concentrations in Chronic Kidney Disease Patients.

    PubMed

    Kaku, Yoshio; Ookawara, Susumu; Miyazawa, Haruhisa; Ito, Kiyonori; Ueda, Yuichirou; Hirai, Keiji; Hoshino, Taro; Mori, Honami; Yoshida, Izumi; Morishita, Yoshiyuki; Tabei, Kaoru

    2016-02-01

    The following conventional calcium correction formula (Payne) is broadly applied for serum calcium estimation: corrected total calcium (TCa) (mg/dL) = TCa (mg/dL) + (4 - albumin (g/dL)); however, it is inapplicable to chronic kidney disease (CKD) patients. A total of 2503 venous samples were collected from 942 all-stage CKD patients, and levels of TCa (mg/dL), ionized calcium ([iCa(2+) ] mmol/L), phosphate (mg/dL), albumin (g/dL), and pH, and other clinical parameters were measured. We assumed corrected TCa (the gold standard) to be equal to eight times the iCa(2+) value (measured corrected TCa). Then, we performed stepwise multiple linear regression analysis by using the clinical parameters and derived a simple formula for corrected TCa approximation. The following formula was devised from multiple linear regression analysis: Approximated  corrected TCa (mg/dL) = TCa + 0.25 × (4 - albumin) + 4 × (7.4 - p H) + 0.1 × (6 - phosphate) + 0.3. Receiver operating characteristic curves analysis illustrated that area under the curve of approximated corrected TCa for detection of measured corrected TCa ≥ 8.4 mg/dL and ≤ 10.4 mg/dL were 0.994 and 0.919, respectively. The intraclass correlation coefficient demonstrated superior agreement using this new formula compared to other formulas (new formula: 0.826, Payne: 0.537, Jain: 0.312, Portale: 0.582, Ferrari: 0.362). In CKD patients, TCa correction should include not only albumin but also pH and phosphate. The approximated corrected TCa from this formula demonstrates superior agreement with the measured corrected TCa in comparison to other formulas. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  11. Comparisons of Computed Mobile Phone Induced SAR in the SAM Phantom to That in Anatomically Correct Models of the Human Head.

    PubMed

    Beard, Brian B; Kainz, Wolfgang; Onishi, Teruo; Iyama, Takahiro; Watanabe, Soichi; Fujiwara, Osamu; Wang, Jianqing; Bit-Babik, Giorgi; Faraone, Antonio; Wiart, Joe; Christ, Andreas; Kuster, Niels; Lee, Ae-Kyoung; Kroeze, Hugo; Siegbahn, Martin; Keshvari, Jafar; Abrishamkar, Houman; Simon, Winfried; Manteuffel, Dirk; Nikoloski, Neviana

    2006-06-05

    The specific absorption rates (SAR) determined computationally in the specific anthropomorphic mannequin (SAM) and anatomically correct models of the human head when exposed to a mobile phone model are compared as part of a study organized by IEEE Standards Coordinating Committee 34, SubCommittee 2, and Working Group 2, and carried out by an international task force comprising 14 government, academic, and industrial research institutions. The detailed study protocol defined the computational head and mobile phone models. The participants used different finite-difference time-domain software and independently positioned the mobile phone and head models in accordance with the protocol. The results show that when the pinna SAR is calculated separately from the head SAR, SAM produced a higher SAR in the head than the anatomically correct head models. Also the larger (adult) head produced a statistically significant higher peak SAR for both the 1- and 10-g averages than did the smaller (child) head for all conditions of frequency and position.

  12. Security evaluation and assurance of electronic health records.

    PubMed

    Weber-Jahnke, Jens H

    2009-01-01

    Electronic Health Records (EHRs) maintain information of sensitive nature. Security requirements in this context are typically multilateral, encompassing the viewpoints of multiple stakeholders. Two main research questions arise from a security assurance point of view, namely how to demonstrate the internal correctness of EHRs and how to demonstrate their conformance in relation to multilateral security regulations. The above notions of correctness and conformance directly relate to the general concept of system verification, which asks the question "are we building the system right?" This should not be confused with the concept of system validation, which asks the question "are we building the right system?" Much of the research in the medical informatics community has been concerned with the latter aspect (validation). However, trustworthy security requires assurances that standards are followed and specifications are met. The objective of this paper is to contribute to filling this gap. We give an introduction to fundamentals of security assurance, summarize current assurance standards, and report on experiences with using security assurance methodology applied to the EHR domain, specifically focusing on case studies in the Canadian context.

  13. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  14. 77 FR 50373 - Deductions for Entertainment Use of Business Aircraft; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-21

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9597] RIN-1545-BF34 Deductions for Entertainment Use of Business Aircraft; Correction AGENCY: Internal Revenue Service (IRS... to the use of business aircraft for entertainment. DATES: Effective Date: This correction is...

  15. 78 FR 29628 - Community Health Needs Assessments for Charitable Hospitals; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-21

    ...-BL30 Community Health Needs Assessments for Charitable Hospitals; Correction AGENCY: Internal Revenue... the community health needs assessment requirements, and related excise tax and reporting obligations... 501(r), 4959, 6012, and 6033 of the Internal Revenue Code. Need for Correction As published April 5...

  16. Implementation of Energy Code Controls Requirements in New Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Hatten, Mike

    Most state energy codes in the United States are based on one of two national model codes; ANSI/ASHRAE/IES 90.1 (Standard 90.1) or the International Code Council (ICC) International Energy Conservation Code (IECC). Since 2004, covering the last four cycles of Standard 90.1 updates, about 30% of all new requirements have been related to building controls. These requirements can be difficult to implement and verification is beyond the expertise of most building code officials, yet the assumption in studies that measure the savings from energy codes is that they are implemented and working correctly. The objective of the current research ismore » to evaluate the degree to which high impact controls requirements included in commercial energy codes are properly designed, commissioned and implemented in new buildings. This study also evaluates the degree to which these control requirements are realizing their savings potential. This was done using a three-step process. The first step involved interviewing commissioning agents to get a better understanding of their activities as they relate to energy code required controls measures. The second involved field audits of a sample of commercial buildings to determine whether the code required control measures are being designed, commissioned and correctly implemented and functioning in new buildings. The third step includes compilation and analysis of the information gather during the first two steps. Information gathered during these activities could be valuable to code developers, energy planners, designers, building owners, and building officials.« less

  17. SWOT analysis of Banff: strengths, weaknesses, opportunities and threats of the international Banff consensus process and classification system for renal allograft pathology.

    PubMed

    Mengel, M; Sis, B; Halloran, P F

    2007-10-01

    The Banff process defined the diagnostic histologic lesions for renal allograft rejection and created a standardized classification system where none had existed. By correcting this deficit the process had universal impact on clinical practice and clinical and basic research. All trials of new drugs since the early 1990s benefited, because the Banff classification of lesions permitted the end point of biopsy-proven rejection. The Banff process has strengths, weaknesses, opportunities and threats (SWOT). The strength is its self-organizing group structure to create consensus. Consensus does not mean correctness: defining consensus is essential if a widely held view is to be proved wrong. The weaknesses of the Banff process are the absence of an independent external standard to test the classification; and its almost exclusive reliance on histopathology, which has inherent limitations in intra- and interobserver reproducibility, particularly at the interface between borderline and rejection, is exactly where clinicians demand precision. The opportunity lies in the new technology such as transcriptomics, which can form an external standard and can be incorporated into a new classification combining the elegance of histopathology and the objectivity of transcriptomics. The threat is the degree to which the renal transplant community will participate in and support this process.

  18. KSC Center Director Bridges addresses the audience at an ISO 9001 certification ceremony

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Center Director Roy Bridges speaks to KSC employees at the ISO certification ceremony held at the Training Auditorium. Bridges was presented an ISO 9001 certificate and plaque awarded to KSC by Det Norske Veritas (DNV), Inc., an international ISO certification organization. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification. Next to Bridges is Heidi Hollingsworth, with the Center for Independent Living, who uses American Sign Language for any hearing-impaired employees in the audience.

  19. 75 FR 65567 - Revised Regulations Concerning Section 403(b) Tax-Sheltered Annuity Contracts; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-26

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9340] RIN 1545-BB64 Revised Regulations Concerning Section 403(b) Tax-Sheltered Annuity Contracts; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correction to final regulations. SUMMARY: This document contains a...

  20. 78 FR 78256 - Shared Responsibility Payment for Not Maintaining Minimum Essential Coverage; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... Shared Responsibility Payment for Not Maintaining Minimum Essential Coverage; Correction AGENCY: Internal... 5000A of the Internal Revenue Code for the shared responsibility payment for not maintaining minimum... language ``for shared responsibility payment for an'' is corrected to read ``for the shared responsibility...

  1. Education Outcomes in a Duty-Hour Flexibility Trial in Internal Medicine.

    PubMed

    Desai, Sanjay V; Asch, David A; Bellini, Lisa M; Chaiyachati, Krisda H; Liu, Manqing; Sternberg, Alice L; Tonascia, James; Yeager, Alyssa M; Asch, Jeremy M; Katz, Joel T; Basner, Mathias; Bates, David W; Bilimoria, Karl Y; Dinges, David F; Even-Shoshan, Orit; Shade, David M; Silber, Jeffrey H; Small, Dylan S; Volpp, Kevin G; Shea, Judy A

    2018-04-19

    Concern persists that inflexible duty-hour rules in medical residency programs may adversely affect the training of physicians. We randomly assigned 63 internal medicine residency programs in the United States to be governed by standard duty-hour policies of the 2011 Accreditation Council for Graduate Medical Education (ACGME) or by more flexible policies that did not specify limits on shift length or mandatory time off between shifts. Measures of educational experience included observations of the activities of interns (first-year residents), surveys of trainees (both interns and residents) and faculty, and intern examination scores. There were no significant between-group differences in the mean percentages of time that interns spent in direct patient care and education nor in trainees' perceptions of an appropriate balance between clinical demands and education (primary outcome for trainee satisfaction with education; response rate, 91%) or in the assessments by program directors and faculty of whether trainees' workload exceeded their capacity (primary outcome for faculty satisfaction with education; response rate, 90%). Another survey of interns (response rate, 49%) revealed that those in flexible programs were more likely to report dissatisfaction with multiple aspects of training, including educational quality (odds ratio, 1.67; 95% confidence interval [CI], 1.02 to 2.73) and overall well-being (odds ratio, 2.47; 95% CI, 1.67 to 3.65). In contrast, directors of flexible programs were less likely to report dissatisfaction with multiple educational processes, including time for bedside teaching (response rate, 98%; odds ratio, 0.13; 95% CI, 0.03 to 0.49). Average scores (percent correct answers) on in-training examinations were 68.9% in flexible programs and 69.4% in standard programs; the difference did not meet the noninferiority margin of 2 percentage points (difference, -0.43; 95% CI, -2.38 to 1.52; P=0.06 for noninferiority). od Institute and the ACGME; iCOMPARE ClinicalTrials.gov number, NCT02274818 .). There was no significant difference in the proportion of time that medical interns spent on direct patient care and education between programs with standard duty-hour policies and programs with more flexible policies. Interns in flexible programs were less satisfied with their educational experience than were their peers in standard programs, but program directors were more satisfied. (Funded by the National Heart, Lung, and Blo

  2. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    PubMed Central

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  3. [Standard of integration management at company level and its auditing].

    PubMed

    Flach, T; Hetzel, C; Mozdzanowski, M; Schian, H-M

    2006-10-01

    Responsibility at company level for the employment of workers with health-related problems or disabilities has increased, inter alia because of integration management at company level according to section 84 (2) of the German Social Code Book IX. Although several recommendations exist, no standard is available for auditing and certification. Such a standard could be a basis for granting premiums according to section 84 (3) of Book IX of the German Social Code. AUDIT AND CERTIFICATION: One product of the international "disability management" movement is the "Consensus Based Disability Management Audit" (CBDMA). The Audit is a systematic and independent measurement of the effectiveness of integration management at company level. CBDMA goals are to give evidence of the quality of the integration management implemented, to identify opportunities for improvement and recommend appropriate corrective and preventive action. In May 2006, the integration management of Ford-Werke GmbH Germany with about 23 900 employees was audited and certified as the first company in Europe. STANDARD OF INTEGRATION MANAGEMENT AT COMPANY LEVEL: In dialogue with corporate practitioners, the international standard of CBDMA has been adapted, completed and verified concerning its practicability. Process orientation is the key approach, and the structure is similar to DIN EN ISO 9001:2000. Its structure is as follows: (1) management-labour responsibility (goals and objectives, program planning, management-labour review), (2) management of resources (disability manager and DM team, employees' participation, cooperation with external partners, infrastructure), (3) communication (internal and external public relations), (4) case management (identifying cases, contact, situation analysis, planning actions, implementing actions and monitoring, process and outcome evaluation), (5) analysis and improvement (analysis and program evaluation), (6) documentation (manual, records).

  4. Inelastic neutron scattering, Raman, vibrational analysis with anharmonic corrections, and scaled quantum mechanical force field for polycrystalline L-alanine

    NASA Astrophysics Data System (ADS)

    Williams, Robert W.; Schlücker, Sebastian; Hudson, Bruce S.

    2008-01-01

    A scaled quantum mechanical harmonic force field (SQMFF) corrected for anharmonicity is obtained for the 23 K L-alanine crystal structure using van der Waals corrected periodic boundary condition density functional theory (DFT) calculations with the PBE functional. Scale factors are obtained with comparisons to inelastic neutron scattering (INS), Raman, and FT-IR spectra of polycrystalline L-alanine at 15-23 K. Calculated frequencies for all 153 normal modes differ from observed frequencies with a standard deviation of 6 wavenumbers. Non-bonded external k = 0 lattice modes are included, but assignments to these modes are presently ambiguous. The extension of SQMFF methodology to lattice modes is new, as are the procedures used here for providing corrections for anharmonicity and van der Waals interactions in DFT calculations on crystals. First principles Born-Oppenheimer molecular dynamics (BOMD) calculations are performed on the L-alanine crystal structure at a series of classical temperatures ranging from 23 K to 600 K. Corrections for zero-point energy (ZPE) are estimated by finding the classical temperature that reproduces the mean square displacements (MSDs) measured from the diffraction data at 23 K. External k = 0 lattice motions are weakly coupled to bonded internal modes.

  5. Real-space post-processing correction of thermal drift and piezoelectric actuator nonlinearities in scanning tunneling microscope images.

    PubMed

    Yothers, Mitchell P; Browder, Aaron E; Bumm, Lloyd A

    2017-01-01

    We have developed a real-space method to correct distortion due to thermal drift and piezoelectric actuator nonlinearities on scanning tunneling microscope images using Matlab. The method uses the known structures typically present in high-resolution atomic and molecularly resolved images as an internal standard. Each image feature (atom or molecule) is first identified in the image. The locations of each feature's nearest neighbors are used to measure the local distortion at that location. The local distortion map across the image is simultaneously fit to our distortion model, which includes thermal drift in addition to piezoelectric actuator hysteresis and creep. The image coordinates of the features and image pixels are corrected using an inverse transform from the distortion model. We call this technique the thermal-drift, hysteresis, and creep transform. Performing the correction in real space allows defects, domain boundaries, and step edges to be excluded with a spatial mask. Additional real-space image analyses are now possible with these corrected images. Using graphite(0001) as a model system, we show lattice fitting to the corrected image, averaged unit cell images, and symmetry-averaged unit cell images. Statistical analysis of the distribution of the image features around their best-fit lattice sites measures the aggregate noise in the image, which can be expressed as feature confidence ellipsoids.

  6. Real-space post-processing correction of thermal drift and piezoelectric actuator nonlinearities in scanning tunneling microscope images

    NASA Astrophysics Data System (ADS)

    Yothers, Mitchell P.; Browder, Aaron E.; Bumm, Lloyd A.

    2017-01-01

    We have developed a real-space method to correct distortion due to thermal drift and piezoelectric actuator nonlinearities on scanning tunneling microscope images using Matlab. The method uses the known structures typically present in high-resolution atomic and molecularly resolved images as an internal standard. Each image feature (atom or molecule) is first identified in the image. The locations of each feature's nearest neighbors are used to measure the local distortion at that location. The local distortion map across the image is simultaneously fit to our distortion model, which includes thermal drift in addition to piezoelectric actuator hysteresis and creep. The image coordinates of the features and image pixels are corrected using an inverse transform from the distortion model. We call this technique the thermal-drift, hysteresis, and creep transform. Performing the correction in real space allows defects, domain boundaries, and step edges to be excluded with a spatial mask. Additional real-space image analyses are now possible with these corrected images. Using graphite(0001) as a model system, we show lattice fitting to the corrected image, averaged unit cell images, and symmetry-averaged unit cell images. Statistical analysis of the distribution of the image features around their best-fit lattice sites measures the aggregate noise in the image, which can be expressed as feature confidence ellipsoids.

  7. [Study on the method for the determination of trace boron, molybdenum, silver, tin and lead in geochemical samples by direct current arc full spectrum direct reading atomic emission spectroscopy (DC-Arc-AES)].

    PubMed

    Hao, Zhi-hong; Yao, Jian-zhen; Tang, Rui-ling; Zhang, Xue-mei; Li, Wen-ge; Zhang, Qin

    2015-02-01

    The method for the determmation of trace boron, molybdenum, silver, tin and lead in geochemical samples by direct current are full spectrum direct reading atomic emission spectroscopy (DC-Arc-AES) was established. Direct current are full spectrum direct reading atomic emission spectrometer with a large area of solid-state detectors has functions of full spectrum direct reading and real-time background correction. The new electrodes and new buffer recipe were proposed in this paper, and have applied for national patent. Suitable analytical line pairs, back ground correcting points of elements and the internal standard method were selected, and Ge was used as internal standard. Multistage currents were selected in the research on current program, and each current set different holding time to ensure that each element has a good signal to noise ratio. Continuous rising current mode selected can effectively eliminate the splash of the sample. Argon as shielding gas can eliminate CN band generating and reduce spectral background, also plays a role in stabilizing the are, and argon flow 3.5 L x min(-1) was selected. Evaporation curve of each element was made, and it was concluded that the evaporation behavior of each element is consistent, and combined with the effects of different spectrographic times on the intensity and background, the spectrographic time of 35s was selected. In this paper, national standards substances were selected as a standard series, and the standard series includes different nature and different content of standard substances which meet the determination of trace boron, molybdenum, silver, tin and lead in geochemical samples. In the optimum experimental conditions, the detection limits for B, Mo, Ag, Sn and Pb are 1.1, 0.09, 0.01, 0.41, and 0.56 microg x g(-1) respectively, and the precisions (RSD, n=12) for B, Mo, Ag, Sn and Pb are 4.57%-7.63%, 5.14%-7.75%, 5.48%-12.30%, 3.97%-10.46%, and 4.26%-9.21% respectively. The analytical accuracy was validated by national standards and the results are in agreement with certified values. The method is simple, rapid, is an advanced analytical method for the determination of trace amounts of geochemical samples' boron, molybdenum, silver, tin and lead, and has a certain practicality.

  8. Performance of Harshaw TLD-100H two-element Dosemeter.

    PubMed

    Luo, L Z; Rotunda, J E

    2006-01-01

    One of the advantages of LiF based thermoluminescent (TL) materials is its tissue-equivalent property. The Harshaw TLD-100H (LiF:Mg,Cu,P) material has demonstrated that it has a near-flat photon energy response and high sensitivity. With the optimized dosemeter filters built into the holder, the Harshaw TLD-100H two-element dosemeter can be used as a whole body personnel dosemeter for gamma, X ray and beta monitoring without the use of an algorithm or correction factor. This paper presents the dose performance of the Harshaw TLD-100H two-element dosemeter against the ANSI N13.11-2001 standard and the results of tests that are required in IEC 1066 International Standard.

  9. IQ Scores Should Be Corrected for the Flynn Effect in High-Stakes Decisions

    ERIC Educational Resources Information Center

    Fletcher, Jack M.; Stuebing, Karla K.; Hughes, Lisa C.

    2010-01-01

    IQ test scores should be corrected for high stakes decisions that employ these assessments, including capital offense cases. If scores are not corrected, then diagnostic standards must change with each generation. Arguments against corrections, based on standards of practice, information present and absent in test manuals, and related issues,…

  10. Development of a primary standard for absorbed dose from unsealed radionuclide solutions

    NASA Astrophysics Data System (ADS)

    Billas, I.; Shipley, D.; Galer, S.; Bass, G.; Sander, T.; Fenwick, A.; Smyth, V.

    2016-12-01

    Currently, the determination of the internal absorbed dose to tissue from an administered radionuclide solution relies on Monte Carlo (MC) calculations based on published nuclear decay data, such as emission probabilities and energies. In order to validate these methods with measurements, it is necessary to achieve the required traceability of the internal absorbed dose measurements of a radionuclide solution to a primary standard of absorbed dose. The purpose of this work was to develop a suitable primary standard. A comparison between measurements and calculations of absorbed dose allows the validation of the internal radiation dose assessment methods. The absorbed dose from an yttrium-90 chloride (90YCl) solution was measured with an extrapolation chamber. A phantom was developed at the National Physical Laboratory (NPL), the UK’s National Measurement Institute, to position the extrapolation chamber as closely as possible to the surface of the solution. The performance of the extrapolation chamber was characterised and a full uncertainty budget for the absorbed dose determination was obtained. Absorbed dose to air in the collecting volume of the chamber was converted to absorbed dose at the centre of the radionuclide solution by applying a MC calculated correction factor. This allowed a direct comparison of the analytically calculated and experimentally determined absorbed dose of an 90YCl solution. The relative standard uncertainty in the measurement of absorbed dose at the centre of an 90YCl solution with the extrapolation chamber was found to be 1.6% (k  =  1). The calculated 90Y absorbed doses from published medical internal radiation dose (MIRD) and radiation dose assessment resource (RADAR) data agreed with measurements to within 1.5% and 1.4%, respectively. This study has shown that it is feasible to use an extrapolation chamber for performing primary standard absorbed dose measurements of an unsealed radionuclide solution. Internal radiation dose assessment methods based on MIRD and RADAR data for 90Y have been validated with experimental absorbed dose determination and they agree within the stated expanded uncertainty (k  =  2).

  11. 77 FR 32995 - Certain Electronic Imaging Devices Corrected: Notice of Receipt of Complaint; Solicitation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    ... INTERNATIONAL TRADE COMMISSION [Docket No. 2898] Certain Electronic Imaging Devices Corrected.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade Commission has received a complaint entitled Certain Electronic Imaging Devices, DN 2898; the...

  12. Inductively coupled plasma-mass spectrometric method for the determination of dissolved trace elements in natural water

    USGS Publications Warehouse

    Garbarino, J.R.; Taylor, Howard E.

    1996-01-01

    An inductively coupled plasma-mass spectrometry method was developed for the determination of dissolved Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Li, Mn, Mo, Ni, Pb, Sr, Tl, U, V, and Zn in natural waters. Detection limits are generally in the 50-100 picogram per milliliter (pg/mL) range, with the exception of As which is in the 1 microgram per liter (ug/L) range. Interferences associated with spectral overlap from concomitant isotopes or molecular ions and sample matrix composition have been identified. Procedures for interference correction and reduction related to isotope selection, instrumental operating conditions, and mathematical data processing techniques are described. Internal standards are used to minimize instrumental drift. The average analytical precision attainable for 5 times the detection limit is about 16 percent. The accuracy of the method was tested using a series of U.S. Geological Survey Standard Reference Water Standards (SWRS), National Research Council Canada Riverine Water Standard, and National Institute of Standards and Technology (NIST) Trace Elements in Water Standards. Average accuracies range from 90 to 110 percent of the published mean values.

  13. Knowledge and application of correct car seat head restraint usage among chiropractic college interns: a cross-sectional study.

    PubMed

    Taylor, John Am; Burke, Jeanmarie; Gavencak, John; Panwar, Pervinder

    2005-03-01

    Cervical spine injuries sustained in rear-end crashes cost at least $7 billion in insurance claims annually in the United States alone. When positioned correctly, head restraint systems have been proven effective in reducing the risk of whiplash associated disorders. Chiropractors should be knowledgeable about the correct use of head restraint systems to educate their patients and thereby prevent or minimize such injuries. The primary objective of this study was to determine the prevalence of correct positioning of car seat head restraints among the interns at our institution. The secondary objective was to determine the same chiropractic interns' knowledge of the correct positioning of car seat head restraints. It was hypothesized that 100 percent of interns would have their head restraint correctly positioned within an acceptable range and that all interns would possess the knowledge to instruct patients in the correct positioning of head restraints. Cross-sectional study of a convenient sample of 30 chiropractic interns from one institution. Interns driving into the parking lot of our health center were asked to volunteer to have measurements taken and to complete a survey. Vertical and horizontal positions of the head restraint were measured using a beam compass. A survey was administered to determine knowledge of correct head restraint position. The results were recorded, entered into a spreadsheet, and analyzed. 13.3 percent of subjects knew the recommended vertical distance and only 20 percent of subjects knew the recommended horizontal distance. Chi Square analyses substantiated that the majority of subjects were unaware of guidelines set forth by the National Highway Traffic Safety Administration (NHTSA) for the correct positioning of the head restraint (chi(2) (vertical) = 16.13, chi(2) (horizontal) = 10.80, p <.05). Only 6.7 percent of the subjects positioned their head restraint at the vertical distance of 6 cm or less (p <.05). However, 60 percent of the subjects positioned their head restraint at the recommended horizontal distance of 7 cm or less, but this was no different than could be expected by chance alone (p >.05). Interestingly, the 13.3 percent of the subjects who were aware of the vertical plane recommendations did not correctly position their own head restraint in the vertical plane. Similarly, only half of the subjects who were aware of the horizontal plane recommendations correctly positioned their head restraint in the horizontal plane. The data suggest that chance alone could account for the correct positioning of the head restraint in our subjects. The results of this cross-sectional study raise concerns about chiropractic intern knowledge and application of correct head restraint positioning. The importance of chiropractors informing patients of the correct head restraint position should be emphasized in chiropractic education to help minimize or prevent injury in patients involved in motor vehicle collisions.

  14. [Determination of five naphthaquinones in Arnebia euchroma by quantitative analysis multi-components with single-marker].

    PubMed

    Zhao, Wen-Wen; Wu, Zhi-Min; Wu, Xia; Zhao, Hai-Yu; Chen, Xiao-Qing

    2016-10-01

    This study is to determine five naphthaquinones (acetylshikonin, β-acetoxyisovalerylalkannin, isobutylshikonin, β,β'-dimethylacrylalkannin,α-methyl-n-butylshikonin) by quantitative analysis of multi-components with a single marker (QAMS). β,β'-Dimethylacrylalkannin was selected as the internal reference substance, and the relative correlation factors (RCFs) of acetylshikonin, β-acetoxyisovalerylalkannin, isobutylshikonin and α-methyl-n-butylshikonin were calculated. Then the ruggedness of relative correction factors was tested on different instruments and columns. Meanwhile, 16 batches of Arnebia euchroma were analyzed by external standard method (ESM) and QAMS, respectively. The peaks were identifited by LC-MS. The ruggedness of relative correction factors was good. And the analytical results calculated by ESM and QAMS showed no difference. The quantitative method established was feasible and suitable for the quality evaluation of A. euchroma. Copyright© by the Chinese Pharmaceutical Association.

  15. 30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...

  16. 30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...

  17. 30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...

  18. 30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...

  19. 76 FR 7818 - Correction to Notice Soliciting Comments on Proposed Voluntary Product Standard PS 2-10 and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... ``Performance Standard for Wood-Based Structural-Use Panels,'' and appears in the body of the notice. NIST is... correct title of the proposed standard is ``Performance Standard for Wood-Based Structural-Use Panels... Product Standard (PS) 2-04, Performance Standard for Wood-Based Structural-Use Panels. This revised...

  20. 75 FR 63380 - Exclusions From Gross Income of Foreign Corporations; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-15

    ... Exclusions From Gross Income of Foreign Corporations; Correction AGENCY: Internal Revenue Service (IRS...) under section 883(a) and (c) of the Internal Revenue Code, concerning the exclusion from gross income of income derived by certain foreign corporations from the international operation of ships or aircraft...

  1. 75 FR 34682 - Bulk Solid Hazardous Materials: Harmonization With the International Maritime Solid Bulk Cargoes...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ...] RIN 1625-AB47 Bulk Solid Hazardous Materials: Harmonization With the International Maritime Solid Bulk... on June 17, 2010, entitled ``Bulk Solid Hazardous Materials: Harmonization With the International Maritime Solid Bulk Cargoes (IMSBC) Code.'' This correction provides correct information with regard to the...

  2. Quantification of HIV-1 DNA using real-time recombinase polymerase amplification.

    PubMed

    Crannell, Zachary Austin; Rohrman, Brittany; Richards-Kortum, Rebecca

    2014-06-17

    Although recombinase polymerase amplification (RPA) has many advantages for the detection of pathogenic nucleic acids in point-of-care applications, RPA has not yet been implemented to quantify sample concentration using a standard curve. Here, we describe a real-time RPA assay with an internal positive control and an algorithm that analyzes real-time fluorescence data to quantify HIV-1 DNA. We show that DNA concentration and the onset of detectable amplification are correlated by an exponential standard curve. In a set of experiments in which the standard curve and algorithm were used to analyze and quantify additional DNA samples, the algorithm predicted an average concentration within 1 order of magnitude of the correct concentration for all HIV-1 DNA concentrations tested. These results suggest that quantitative RPA (qRPA) may serve as a powerful tool for quantifying nucleic acids and may be adapted for use in single-sample point-of-care diagnostic systems.

  3. Manual of Standards for Juvenile Training Schools and Services.

    ERIC Educational Resources Information Center

    Commission on Accreditation for Corrections, Rockville, MD.

    This manual of standards for juvenile training schools and services contains 487 American Correctional Association standards for the accreditation of juvenile training schools (youth development centers, villages, correction centers, treatment centers, service centers, homes for boys and girls, camps, and ranches). Standards presented are…

  4. 76 FR 39018 - Commercial Driver's License Testing and Commercial Learner's Permit Standards; Corrections

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-05

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration 49 CFR Parts 383 and 384... Permit Standards; Corrections AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... (CDL) knowledge and skills testing standards and establishes new minimum Federal standards for States...

  5. Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

    NASA Technical Reports Server (NTRS)

    Morgan, Leah; Tappa, Mike; Ellam, Rob; Mark, Darren; Higgins, John; Simon, Justin I.

    2013-01-01

    Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1s) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

  6. The type specimens of Hekstra's owl

    USGS Publications Warehouse

    Browning, M.R.

    1989-01-01

    Twenty-four new subspecies of New World owls of the genus Otus were named in a paper by Hekstra (1982b) issued 17 December 1982. These same new names also appeared in Hekstra's (1982a) unpublished thesis. The holotypes of the new taxa are in 10 different collections, most of which are in the United States. Incorrect information was published with regard to museum designation, museum number, and collecting locality of many of the holotypes. I here list the holotypes with their correct specimen label data. The species names are here presented in the sequence proposed by Marshall & King (1988). The subspecies are generally arranged from north to south. The type localities given are standardized, and the spellings are corrected where required. Abbreviations for museum designations are given under acknowledgments. The numbers following the names refer to the pages where the descriptions were given (Hekstra 1982b). Several of the scientific names proposed were spelled incorrectly and these have been emended in accord with Article 31c and Appendix D of the International Code (International Commission on Zoological Nomenclature 1985). Taxonomic comments are appended for a small number of Hekstra's proposed taxa. The remaining forms he named require further study.

  7. An overview of bacterial nomenclature with special reference to plant pathogens.

    PubMed

    Young, J M

    2008-12-01

    The nomenclature of plant pathogenic bacteria is regulated by the International Code of Nomenclature of Prokaryotes and the International Standards for Naming Pathovars of Phytopathogenic Bacteria. The object of these regulations is to ensure that nomenclature is unambiguous, with correct designations in genera and species and, for many plant pathogens, in infrasubspecies as pathovars. Failure to apply these regulations or to apply them carelessly introduces confusion and misunderstanding over the intended identity of particular pathogens. In this review, bacterial nomenclature is introduced in the context of general communication, with a brief history of the origins of modern bacterial nomenclature. A critical overview of the Code pays most attention to those Rules that are relevant to naming new taxa and new combinations, with comments on common misunderstandings. There follows an account of the application of infrasubspecies, specifically of pathovars as regulated by the Standards for Naming Pathovars. Both the Code and Standards, written almost 30 years ago in response to the exigencies of the time, could be revised to improve clarity. It is not possible for either the Code or the Standards to give formal guidance to the process of translation of pathovars, governed by the Standards, to higher taxonomic ranks, governed by the Code. If the introduction of ambiguity of names is to be avoided in making such translations, then it is the responsibility of individual bacteriologists to consider carefully the nomenclatural implications and outcomes of their proposals.

  8. Curriculum-Based Measurement in Writing: Predicting the Success of High-School Students on State Standards Tests

    ERIC Educational Resources Information Center

    Espin, Christine; Wallace, Teri; Campbell, Heather; Lembke, Erica S.; Long, Jeffrey D.; Ticha, Renata

    2008-01-01

    We examined the technical adequacy of writing progress measures as indicators of success on state standards tests. Tenth-grade students wrote for 10 min, marking their samples at 3, 5, and 7 min. Samples were scored for words written, words spelled correctly, and correct and correct minus incorrect word sequences. The number of correct minus…

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CORRECTING ELECTRONIC DATA (HAND ENTRY AND SCANNED) (UA-D-25.0)

    EPA Science Inventory

    The purpose of this SOP is to define the procedure to provide a standard method for correcting electronic data errors. The procedure defines (1) when electronic data may be corrected and by whom, (2) the process of correcting the data, and (3) the process of documenting the corr...

  10. 75 FR 62141 - In the Matter of Certain Energy Drink Products; Notice of Issuance of a Corrected General...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-07

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-678] In the Matter of Certain Energy Drink Products; Notice of Issuance of a Corrected General Exclusion Order AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade...

  11. 77 FR 12598 - Notice Correction; A Multi-Center International Hospital-Based Case-Control Study of Lymphoma in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Notice Correction; A Multi-Center International Hospital-Based Case-Control Study of Lymphoma in Asia (AsiaLymph) (NCI) The Federal... project titled, ``A multi-center international hospital-based case-control study of lymphoma in Asia (Asia...

  12. 77 FR 61789 - Workforce Investment Act of 1998 (WIA); Lower Living Standard Income Level (LLSIL); Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-11

    ... DEPARTMENT OF LABOR Employment and Training Administration Workforce Investment Act of 1998 (WIA); Lower Living Standard Income Level (LLSIL); Correction AGENCY: Employment and Training Administration, Labor. ACTION: Notice; correction. SUMMARY: The Employment and Training Administration (ETA) published...

  13. UTC Dissemination to the Real-Time User

    NASA Technical Reports Server (NTRS)

    Levine, Judah

    1996-01-01

    The current definition of Coordinated Universal Time (UTC) dates from 1972. The duration of a UTC second is defined in terms of the frequency of a hyperfine transition in the ground state of cesium. This standard frequency is realized in a number of different laboratories using ensembles of commercial cesium clocks and a few primary frequency standards. The data from all of these devices are transmitted periodically to the Bureau International des Poids et Mesures (BIPM) in Sevres, France, where they are combined in a statistical procedure to produce International Atomic Time (TAI). The time of this scale is adjusted as needed ('coordinated') by adding or dropping integer seconds so as to keep it within plus or minus 0.9 s of UT1, a time scale based on the observation of the transit times of stars and corrected for the predicted seasonal variations in these observations. When the leap seconds are included into TAI, the result is called UTC. The difference between TAI and UTC is therefore an exact integer number of seconds. This difference is currently 29 s and will become 30 s at 0 UTC on 1 January 1996.

  14. Beam uniformity of flat top lasers

    NASA Astrophysics Data System (ADS)

    Chang, Chao; Cramer, Larry; Danielson, Don; Norby, James

    2015-03-01

    Many beams that output from standard commercial lasers are multi-mode, with each mode having a different shape and width. They show an overall non-homogeneous energy distribution across the spot size. There may be satellite structures, halos and other deviations from beam uniformity. However, many scientific, industrial and medical applications require flat top spatial energy distribution, high uniformity in the plateau region, and complete absence of hot spots. Reliable standard methods for the evaluation of beam quality are of great importance. Standard methods are required for correct characterization of the laser for its intended application and for tight quality control in laser manufacturing. The International Organization for Standardization (ISO) has published standard procedures and definitions for this purpose. These procedures have not been widely adopted by commercial laser manufacturers. This is due to the fact that they are unreliable because an unrepresentative single-pixel value can seriously distort the result. We hereby propose a metric of beam uniformity, a way of beam profile visualization, procedures to automatically detect hot spots and beam structures, and application examples in our high energy laser production.

  15. A method and results of color calibration for the Chang'e-3 terrain camera and panoramic camera

    NASA Astrophysics Data System (ADS)

    Ren, Xin; Li, Chun-Lai; Liu, Jian-Jun; Wang, Fen-Fei; Yang, Jian-Feng; Liu, En-Hai; Xue, Bin; Zhao, Ru-Jin

    2014-12-01

    The terrain camera (TCAM) and panoramic camera (PCAM) are two of the major scientific payloads installed on the lander and rover of the Chang'e 3 mission respectively. They both use a Bayer color filter array covering CMOS sensor to capture color images of the Moon's surface. RGB values of the original images are related to these two kinds of cameras. There is an obvious color difference compared with human visual perception. This paper follows standards published by the International Commission on Illumination to establish a color correction model, designs the ground calibration experiment and obtains the color correction coefficient. The image quality has been significantly improved and there is no obvious color difference in the corrected images. Ground experimental results show that: (1) Compared with uncorrected images, the average color difference of TCAM is 4.30, which has been reduced by 62.1%. (2) The average color differences of the left and right cameras in PCAM are 4.14 and 4.16, which have been reduced by 68.3% and 67.6% respectively.

  16. Comparisons of Computed Mobile Phone Induced SAR in the SAM Phantom to That in Anatomically Correct Models of the Human Head

    PubMed Central

    Beard, Brian B.; Kainz, Wolfgang; Onishi, Teruo; Iyama, Takahiro; Watanabe, Soichi; Fujiwara, Osamu; Wang, Jianqing; Bit-Babik, Giorgi; Faraone, Antonio; Wiart, Joe; Christ, Andreas; Kuster, Niels; Lee, Ae-Kyoung; Kroeze, Hugo; Siegbahn, Martin; Keshvari, Jafar; Abrishamkar, Houman; Simon, Winfried; Manteuffel, Dirk; Nikoloski, Neviana

    2018-01-01

    The specific absorption rates (SAR) determined computationally in the specific anthropomorphic mannequin (SAM) and anatomically correct models of the human head when exposed to a mobile phone model are compared as part of a study organized by IEEE Standards Coordinating Committee 34, SubCommittee 2, and Working Group 2, and carried out by an international task force comprising 14 government, academic, and industrial research institutions. The detailed study protocol defined the computational head and mobile phone models. The participants used different finite-difference time-domain software and independently positioned the mobile phone and head models in accordance with the protocol. The results show that when the pinna SAR is calculated separately from the head SAR, SAM produced a higher SAR in the head than the anatomically correct head models. Also the larger (adult) head produced a statistically significant higher peak SAR for both the 1- and 10-g averages than did the smaller (child) head for all conditions of frequency and position. PMID:29515260

  17. Finite temperature corrections and embedded strings in noncommutative geometry and the standard model with neutrino mixing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martins, R. A.

    The recent extension of the standard model to include massive neutrinos in the framework of noncommutative geometry and the spectral action principle involves new scalar fields and their interactions with the usual complex scalar doublet. After ensuring that they bring no unphysical consequences, we address the question of how these fields affect the physics predicted in the Weinberg-Salam theory, particularly in the context of the electroweak phase transition. Applying the Dolan-Jackiw procedure, we calculate the finite temperature corrections, and find that the phase transition is first order. The new scalar interactions significantly improve the stability of the electroweak Z string,more » through the 'bag' phenomenon described by Vachaspati and Watkins ['Bound states can stabilize electroweak strings', Phys. Lett. B 318, 163-168 (1993)]. (Recently, cosmic strings have climbed back into interest due to a new evidence.) Sourced by static embedded strings, an internal space analogy of Cartan's torsion is drawn, and a possible Higgs-force-like 'gravitational' effect of this nonpropagating torsion on the fermion masses is described. We also check that the field generating the Majorana mass for the {nu}{sub R} is nonzero in the physical vacuum.« less

  18. Comparison of direct measurement methods for headset noise exposure in the workplace

    PubMed Central

    Nassrallah, Flora G.; Giguère, Christian; Dajani, Hilmi R.; Ellaham, Nicolas N.

    2016-01-01

    The measurement of noise exposure from communication headsets poses a methodological challenge. Although several standards describe methods for general noise measurements in occupational settings, these are not directly applicable to noise assessments under communication headsets. For measurements under occluded ears, specialized methods have been specified by the International Standards Organization (ISO 11904) such as the microphone in a real ear and manikin techniques. Simpler methods have also been proposed in some national standards such as the use of general purpose artificial ears and simulators in conjunction with single number corrections to convert measurements to the equivalent diffuse field. However, little is known about the measurement agreement between these various methods and the acoustic manikin technique. Twelve experts positioned circum-aural, supra-aural and insert communication headsets on four different measurement setups (Type 1, Type 2, Type 3.3 artificial ears, and acoustic manikin). Fit-refit measurements of four audio communication signals were taken under quiet laboratory conditions. Data were transformed into equivalent diffuse-field sound levels using third-octave procedures. Results indicate that the Type 1 artificial ear is not suited for the measurement of sound exposure under communication headsets, while Type 2 and Type 3.3 artificial ears are in good agreement with the acoustic manikin technique. Single number corrections were found to introduce a large measurement uncertainty, making the use of the third-octave transformation preferable. PMID:26960783

  19. The effects of environmental and classroom noise on the academic attainments of primary school children.

    PubMed

    Shield, Bridget M; Dockrell, Julie E

    2008-01-01

    While at school children are exposed to various types of noise including external, environmental noise and noise generated within the classroom. Previous research has shown that noise has detrimental effects upon children's performance at school, including reduced memory, motivation, and reading ability. In England and Wales, children's academic performance is assessed using standardized tests of literacy, mathematics, and science. A study has been conducted to examine the impact, if any, of chronic exposure to external and internal noise on the test results of children aged 7 and 11 in London (UK) primary schools. External noise was found to have a significant negative impact upon performance, the effect being greater for the older children. The analysis suggested that children are particularly affected by the noise of individual external events. Test scores were also affected by internal classroom noise, background levels being significantly related to test results. Negative relationships between performance and noise levels were maintained when the data were corrected for socio-economic factors relating to social deprivation, language, and special educational needs. Linear regression analysis has been used to estimate the maximum levels of external and internal noise which allow the schools surveyed to achieve required standards of literacy and numeracy.

  20. Amide proton transfer imaging of brain tumors using a self-corrected 3D fast spin-echo dixon method: Comparison With separate B0 correction.

    PubMed

    Togao, Osamu; Keupp, Jochen; Hiwatashi, Akio; Yamashita, Koji; Kikuchi, Kazufumi; Yoneyama, Masami; Honda, Hiroshi

    2017-06-01

    To assess the quantitative performance of three-dimensional (3D) fast spin-echo (FSE) Dixon amide proton transfer (APT) imaging of brain tumors compared with B 0 correction with separate mapping methods. Twenty-two patients with brain tumors (54.2 ± 18.7 years old, 12 males and 10 females) were scanned at 3 Tesla (T). Z-spectra were obtained at seven different frequency offsets at ±3.1 ppm, ± 3.5 ppm, ± 3.9 ppm, and -1560 ppm. The scan was repeated three times at +3.5 ppm with echo shifts for Dixon B 0 mapping. The APT image corrected by a three-point Dixon-type B 0 map from the same scan (3D-Dixon) or a separate B 0 map (2D-separate and 3D-separate), and an uncorrected APT image (3D-uncorrected) were generated. We compared the APT-weighted signals within a tumor obtained with each 3D method with those obtained with 2D-separate as a reference standard. Excellent agreements and correlations with the 2D-separate were obtained by the 3D-Dixon method for both mean (ICC = 0.964, r = 0.93, P < 0.0001) and 90th-percentile (ICC = 0.972, r = 0.95, P < 0.0001) APT-weighted signals. These agreements and correlations for 3D-Dixon were better than those obtained by the 3D-uncorrected and 3D-separate methods. The 3D FSE Dixon APT method with intrinsic B 0 correction offers a quantitative performance that is similar to that of established two-dimensional (2D) methods. Magn Reson Med 77:2272-2279, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  1. Accurate determination of brain metabolite concentrations using ERETIC as external reference.

    PubMed

    Zoelch, Niklaus; Hock, Andreas; Heinzer-Schweizer, Susanne; Avdievitch, Nikolai; Henning, Anke

    2017-08-01

    Magnetic Resonance Spectroscopy (MRS) can provide in vivo metabolite concentrations in standard concentration units if a reliable reference signal is available. For 1 H MRS in the human brain, typically the signal from the tissue water is used as the (internal) reference signal. However, a concentration determination based on the tissue water signal most often requires a reliable estimate of the water concentration present in the investigated tissue. Especially in clinically interesting cases, this estimation might be difficult. To avoid assumptions about the water in the investigated tissue, the Electric REference To access In vivo Concentrations (ERETIC) method has been proposed. In this approach, the metabolite signal is compared with a reference signal acquired in a phantom and potential coil-loading differences are corrected using a synthetic reference signal. The aim of this study, conducted with a transceiver quadrature head coil, was to increase the accuracy of the ERETIC method by correcting the influence of spatial B 1 inhomogeneities and to simplify the quantification with ERETIC by incorporating an automatic phase correction for the ERETIC signal. Transmit field ( B1+) differences are minimized with a volume-selective power optimization, whereas reception sensitivity changes are corrected using contrast-minimized images of the brain and by adapting the voxel location in the phantom measurement closely to the position measured in vivo. By applying the proposed B 1 correction scheme, the mean metabolite concentrations determined with ERETIC in 21 healthy subjects at three different positions agree with concentrations derived with the tissue water signal as reference. In addition, brain water concentrations determined with ERETIC were in agreement with estimations derived using tissue segmentation and literature values for relative water densities. Based on the results, the ERETIC method presented here is a valid tool to derive in vivo metabolite concentration, with potential advantages compared with internal water referencing in diseased tissue. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Legal aspects of administrating antipsychotic medications to jail and prison inmates.

    PubMed

    Dlugacz, Henry; Wimmer, Christopher

    2013-01-01

    The administration of antipsychotic medications to jail and prison inmates involves two related components: conducting the informed consent process in a coercive environment and, where consent is not obtained, forcible administration of medication if needed. In the United States, both involve common law, statutory, and constitutional principles. Obtaining informed consent in correctional institutions is complicated. Patients in correctional institutions lack access to alternate sources of information, and depend on the correctional system completely - a system which they may distrust. This may influence the patient's view of the administering physician. Where consent cannot be obtained, forcible administration may be legally permissible for two primary reasons: to restore a criminal defendant to competency in order to stand trial and to ameliorate severe symptoms of mental disability, particularly when they threaten the safety of self, others, or in some instances, property. The interests at stake for the individual and the government, and the legal standards developed to balance these interests, differ between the two situations. When considering challenges to forcible medication of inmates serving a prison sentence, the United States Supreme Court has treated the interest of the institution in maintaining security as paramount. By contrast, when considering challenges to forcible medication of pretrial detainees, the Court's concern for the fair trial rights guaranteed by the Sixth Amendment has seemingly led it to moderate its emphasis on security. However, this distinction is not stable and may in fact be breaking down, as the recent case of Jared Loughner demonstrates. This article discusses the various federal, state, and international legal standards applicable to both informed consent and forcible medication, and their implementation in the correctional setting, focusing on issues related to the United States. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. 75 FR 17036 - Energy Conservation Program: Energy Conservation Standards for Small Electric Motors; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... Conservation Program: Energy Conservation Standards for Small Electric Motors; Correction AGENCY: Office of... standards for small electric motors, which was published on March 9, 2010. In that final rule, the U.S... titled ``Energy Conservation Standards for Small Electric Motors.'' 75 FR 10874. Since the publication of...

  4. Evaluation of proficiency in using different inhaler devices among intern doctors.

    PubMed

    Kshatriya, Ravish M; Khara, Nimit V; Paliwal, Rajiv P; Patel, Satish N

    2016-01-01

    Doctors may have deficiencies in the ability to use different inhalers, which in turn, can result in improper technique by the patients and poorly controlled asthma and chronic obstructive pulmonary disease (COPD). To evaluate intern doctors' proficiency in using various inhaler devices. Seventy interns were evaluated for their proficiency in using pressurized metered dose inhaler (pMDI), pMDI with spacer, rotahaler, turbuhaler, and nebulizer. A structured assessment sheet was scored for identification and preparation of device, administration, coordination, and skill of explanation on a scale of 0-5. Common errors such as failure to shake pMDI before use, inability to identify the empty device, inadequate breath holding, and failure to advise gargles after use were recorded. pMDI and pMDI with spacer were identified correctly by 89% and 79% of interns. Over 90% could identify rotahaler and nebulizer whereas only 9% could identify turbuhaler. 79% and 60% could prepare pMDI and pMDI with spacer appropriately. Nebulizer preparation was performed correctly by 79% and almost all interns could not prepare turbuhaler. Only one intern administered turbuhaler correctly. About half of the participants knew the correct co-ordination for pMDI and pMDI with spacer. Two interns showed proper co-ordination in using turbuhaler. None could provide correct explanation for turbuhaler usage; whereas 76% and 70% did it for nebulizer and rotahaler, respectively. Only 43% of interns remembered to shake pMDI before use. Proficiency in using different inhaler devices amongst interns is poor. It is essential to provide adequate training for inhaler devices usage to medical graduates for proper management of asthma and COPD patients by those future primary care physicians and specialists.

  5. Implementation of a virtual laboratory for training on sound insulation testing and uncertainty calculations in acoustic tests.

    PubMed

    Asensio, C; Gasco, L; Ruiz, M; Recuero, M

    2015-02-01

    This paper describes a methodology and case study for the implementation of educational virtual laboratories for practice training on acoustic tests according to international standards. The objectives of this activity are (a) to help the students understand and apply the procedures described in the standards and (b) to familiarize the students with the uncertainty in measurement and its estimation in acoustics. The virtual laboratory will not focus on the handling and set-up of real acoustic equipment but rather on procedures and uncertainty. The case study focuses on the application of the virtual laboratory for facade sound insulation tests according to ISO 140-5:1998 (International Organization for Standardization, Geneva, Switzerland, 1998), and the paper describes the causal and stochastic models and the constraints applied in the virtual environment under consideration. With a simple user interface, the laboratory will provide measurement data that the students will have to process to report the insulation results that must converge with the "virtual true values" in the laboratory. The main advantage of the virtual laboratory is derived from the customization of factors in which the student will be instructed or examined (for instance, background noise correction, the detection of sporadic corrupted observations, and the effect of instrument precision).

  6. Standardized training in nurse model travel clinics.

    PubMed

    Sofarelli, Theresa A; Ricks, Jane H; Anand, Rahul; Hale, Devon C

    2011-01-01

    International travel plays a significant role in the emergence and redistribution of major human diseases. The importance of travel medicine clinics for preventing morbidity and mortality has been increasingly appreciated, although few studies have thus far examined the management and staff training strategies that result in successful travel-clinic operations. Here, we describe an example of travel-clinic operation and management coordinated through the University of Utah School of Medicine, Division of Infectious Diseases. This program, which involves eight separate clinics distributed statewide, functions both to provide patient consult and care services, as well as medical provider training and continuing medical education (CME). Initial training, the use of standardized forms and protocols, routine chart reviews and monthly continuing education meetings are the distinguishing attributes of this program. An Infectious Disease team consisting of one medical doctor (MD) and a physician assistant (PA) act as consultants to travel nurses who comprise the majority of clinic staff. Eight clinics distributed throughout the state of Utah serve approximately 6,000 travelers a year. Pre-travel medical services are provided by 11 nurses, including 10 registered nurses (RNs) and 1 licensed practical nurse (LPN). This trained nursing staff receives continuing travel medical education and participate in the training of new providers. All nurses have completed a full training program and 7 of the 11 (64%) of clinic nursing staff serve more than 10 patients a week. Quality assurance measures show that approximately 0.5% of charts reviewed contain a vaccine or prescription error which require patient notification for correction. Using an initial training program, standardized patient intake forms, vaccine and prescription protocols, preprinted prescriptions, and regular CME, highly trained nurses at travel clinics are able to provide standardized pre-travel care to international travelers originating from Utah. © 2010 International Society of Travel Medicine.

  7. Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Zivkovic, V.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Directorate of Measures and Precious Metals (DMDM), Beograd, Serbia, was carried out from January to March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMA (ZA), were transported by freight to DMDM. At DMDM, the reference standard for DC voltage is a Josephson Voltage Standard. The output electromotive force of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DMDM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DMDM, at the level of 1.018 V and 10 V, at DMDM, UDMDM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 13 February 2014. UDMDM - UBIPM = 0.094 µV uc = 0.072 µV, at 1 V UDMDM - UBIPM = 0.39 µV uc = 0.12 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DMDM, based on KJ-90, and the uncertainty related to the comparison. The results at the 10 V level are not covered by the uncertainties with a coverage factor of 2. After the distribution of the Draft A, the DMDM discovered that the pressure gauge was defective. Some considerations on the correction to apply on the comparison result and the corresponding uncertainties are presented in the report. Nevertheless, the above results fully cover the CMCs of DMDM which are significantly larger. No corrections for temperature and pressure are applied in calibrations for customers' secondary standards. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Importance of implementing an analytical quality control system in a core laboratory.

    PubMed

    Marques-Garcia, F; Garcia-Codesal, M F; Caro-Narros, M R; Contreras-SanFeliciano, T

    2015-01-01

    The aim of the clinical laboratory is to provide useful information for screening, diagnosis and monitoring of disease. The laboratory should ensure the quality of extra-analytical and analytical process, based on set criteria. To do this, it develops and implements a system of internal quality control, designed to detect errors, and compare its data with other laboratories, through external quality control. In this way it has a tool to detect the fulfillment of the objectives set, and in case of errors, allowing corrective actions to be made, and ensure the reliability of the results. This article sets out to describe the design and implementation of an internal quality control protocol, as well as its periodical assessment intervals (6 months) to determine compliance with pre-determined specifications (Stockholm Consensus(1)). A total of 40 biochemical and 15 immunochemical methods were evaluated using three different control materials. Next, a standard operation procedure was planned to develop a system of internal quality control that included calculating the error of the analytical process, setting quality specifications, and verifying compliance. The quality control data were then statistically depicted as means, standard deviations, and coefficients of variation, as well as systematic, random, and total errors. The quality specifications were then fixed and the operational rules to apply in the analytical process were calculated. Finally, our data were compared with those of other laboratories through an external quality assurance program. The development of an analytical quality control system is a highly structured process. This should be designed to detect errors that compromise the stability of the analytical process. The laboratory should review its quality indicators, systematic, random and total error at regular intervals, in order to ensure that they are meeting pre-determined specifications, and if not, apply the appropriate corrective actions. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  9. 78 FR 22773 - Revisions to Reliability Standard for Transmission Vegetation Management; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-17

    ...; Order No. 777] Revisions to Reliability Standard for Transmission Vegetation Management; Correction... other requirements the North American Electric Reliability Corporation (NERC) needs to submit when modifying certain Reliability Standards. DATES: Effective on May 28, 2013. FOR FURTHER INFORMATION CONTACT...

  10. Combined apatite fission track and U-Pb dating by LA-ICPMS

    NASA Astrophysics Data System (ADS)

    Chew, D. M.; Donelick, R. A.

    2012-04-01

    Apatite is a common accessory mineral in igneous, metamorphic and clastic sedimentary rocks. It is a nearly ubiquitous accessory phase in igneous rocks, is common in metamorphic rocks of pelitic, carbonate, basaltic, and ultramafic composition and is virtually ubiquitous in clastic sedimentary rocks. In contrast to the polycyclic behavior of the stable heavy mineral zircon, apatite is unstable in acidic groundwaters and has limited mechanical stability in sedimentary transport systems. Apatite has many potential applications in provenance studies, particularly as it likely represents first-cycle detritus. Fission track and U-Pb dating are very powerful techniques in apatite provenance studies. They yield complementary information, with the apatite fission-track system yielding low-temperature exhumation ages and the U-Pb system yielding high-temperature cooling ages which constrain the timing of apatite crystallization. This study focuses on integrating apatite fission track and U-Pb dating by the LA-ICPMS method. Our approach is intentionally broad in scope, and is applicable to any quadrupole or rapid-scanning magnetic-sector LA-ICPMS system. Calculating uranium concentrations in fission-track dating by LA-ICPMS increases the speed of analysis and sample throughput compared to the conventional external detector method and avoids the need for neutron irradiation (Hasebe et al., 2004). LA-ICPMS-based uranium measurements in apatite are measured relative to an internal concentration standard (typically 43Ca). Ca in apatite is not always stochiometric as minor cations (Mn2+, Sr2+, Ba2+ and Fe2+) and REE can substitute with Ca2+. These substitutions must be quantified by multi-elemental LA-ICPMS analyses. Such data are also useful for discriminating between different apatite populations in sedimentary or volcaniclastic rocks based on their trace-element chemistry. Low U, Th and radiogenic Pb concentrations, elevated common Pb / radiogenic Pb ratios and U-Pb elemental fractionation are challenges in apatite U-Pb dating by LA-ICPMS. Isochron-based approaches to common Pb correction require a significant spread in common Pb / radiogenic Pb ratios. This is not usually possible on individual detrital apatite grains and hence the 204Pb-, 207Pb- and 208Pb-correction methods are preferred. Uranium concentration measurements by ICPMS employ large peak jumps (the internal standard is a Ca isotope) which require a quadrupole or a rapid-scanning magnetic-sector LA-ICPMS system. These single-collector instruments require a prohibitively long dwell time on the low intensity 204Pb peak to measure it accurately and hence the 207Pb- and 208Pb-correction methods are preferred. Uranium-concentration measurements in fission-track dating require well-constrained ablation depths during analysis and hence spot analyses are preferred to rastering. Laser-induced U-Pb fractionation is corrected for by sample-standard bracketing using a variety of apatite standards (Durango, Emerald Lake, Fish Canyon Tuff, Kovdor, Otter Lake and McClure Mountain syenite). Of these, Emerald Lake (Chew et al., 2011) and McClure Mountain syenite apatite are recommended as primary standards with Durango apatite making a suitable secondary standard. Offline data-reduction uses custom-written software for ICPMS data processing (the UPbICP package of Ray Donelick) or the freeware IOLITE data-reduction package of Paton et al. (2010).

  11. Sulfate and sulfide sulfur isotopes (δ34S and δ33S) measured by solution and laser ablation MC-ICP-MS: An enhanced approach using external correction

    USGS Publications Warehouse

    Pribil, Michael; Ridley, William I.; Emsbo, Poul

    2015-01-01

    Isotope ratio measurements using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) commonly use standard-sample bracketing with a single isotope standard for mass bias correction for elements with narrow-range isotope systems measured by MC-ICP-MS, e.g. Cu, Fe, Zn, and Hg. However, sulfur (S) isotopic composition (δ34S) in nature can range from at least − 40 to + 40‰, potentially exceeding the ability of standard-sample bracketing using a single sulfur isotope standard to accurately correct for mass bias. Isotopic fractionation via solution and laser ablation introduction was determined during sulfate sulfur (Ssulfate) isotope measurements. An external isotope calibration curve was constructed using in-house and National Institute of Standards and Technology (NIST) Ssulfate isotope reference materials (RM) in an attempt to correct for the difference. The ability of external isotope correction for Ssulfate isotope measurements was evaluated by analyzing NIST and United States Geological Survey (USGS) Ssulfate isotope reference materials as unknowns. Differences in δ34Ssulfate between standard-sample bracketing and standard-sample bracketing with external isotope correction for sulfate samples ranged from 0.72‰ to 2.35‰ over a δ34S range of 1.40‰ to 21.17‰. No isotopic differences were observed when analyzing Ssulfide reference materials over a δ34Ssulfide range of − 32.1‰ to 17.3‰ and a δ33S range of − 16.5‰ to 8.9‰ via laser ablation (LA)-MC-ICP-MS. Here, we identify a possible plasma induced fractionation for Ssulfate and describe a new method using external isotope calibration corrections using solution and LA-MC-ICP-MS.

  12. Standard Reference Material (SRM 1990) for Single Crystal Diffractometer Alignment

    USGS Publications Warehouse

    Wong-Ng, W.; Siegrist, T.; DeTitta, G.T.; Finger, L.W.; Evans, H.T.; Gabe, E.J.; Enright, G.D.; Armstrong, J.T.; Levenson, M.; Cook, L.P.; Hubbard, C.R.

    2001-01-01

    An international project was successfully completed which involved two major undertakings: (1) a round-robin to demonstrate the viability of the selected standard and (2) the certification of the lattice parameters of the SRM 1990, a Standard Reference Material?? for single crystal diffractometer alignment. This SRM is a set of ???3500 units of Cr-doped Al2O3, or ruby spheres [(0 420.011 mole fraction % Cr (expanded uncertainty)]. The round-robin consisted of determination of lattice parameters of a pair of crystals' the ruby sphere as a standard, and a zeolite reference to serve as an unknown. Fifty pairs of crystals were dispatched from Hauptman-Woodward Medical Research Institute to volunteers in x-ray laboratories world-wide. A total of 45 sets of data was received from 32 laboratories. The mean unit cell parameters of the ruby spheres was found to be a=4.7608 A?? ?? 0.0062 A??, and c=12.9979 A?? ?? 0.020 A?? (95 % intervals of the laboratory means). The source of errors of outlier data was identified. The SRM project involved the certification of lattice parameters using four well-aligned single crystal diffractometers at (Bell Laboratories) Lucent Technologies and at NRC of Canada (39 ruby spheres), the quantification of the Cr content using a combined microprobe and SEM/EDS technique, and the evaluation of the mosaicity of the ruby spheres using a double-crystal spectrometry method. A confirmation of the lattice parameters was also conducted using a Guinier-Ha??gg camera. Systematic corrections of thermal expansion and refraction corrections were applied. These rubies_ are rhombohedral, with space group R3c. The certified mean unit cell parameters are a=4.76080 ?? 0.00029 A??, and c=12 99568 A?? ?? 0.00087 A?? (expanded uncertainty). These certified lattice parameters fall well within the results of those obtained from the international round-robin study. The Guinier-Ha??gg transmission measurements on five samples of powdered rubies (a=4.7610 A?? ?? 0.0013 A??, and c=12.9954 A?? ?? 0.0034 A??) agreed well with the values obtained from the single crystal spheres.

  13. Standard Reference Material (SRM 1990) For Single Crystal Diffractometer Alignment

    PubMed Central

    Wong-Ng, W.; Siegrist, T.; DeTitta, G. T.; Finger, L. W.; Evans, H. T.; Gabe, E. J.; Enright, G. D.; Armstrong, J. T.; Levenson, M.; Cook, L. P.; Hubbard, C. R.

    2001-01-01

    An international project was successfully completed which involved two major undertakings: (1) a round-robin to demonstrate the viability of the selected standard and (2) the certification of the lattice parameters of the SRM 1990, a Standard Reference Material® for single crystal diffractometer alignment. This SRM is a set of ≈3500 units of Cr-doped Al2O3, or ruby spheres [(0.420.011 mole fraction % Cr (expanded uncertainty)]. The round-robin consisted of determination of lattice parameters of a pair of crystals: the ruby sphere as a standard, and a zeolite reference to serve as an unknown. Fifty pairs of crystals were dispatched from Hauptman-Woodward Medical Research Institute to volunteers in x-ray laboratories world-wide. A total of 45 sets of data was received from 32 laboratories. The mean unit cell parameters of the ruby spheres was found to be a=4.7608 ű0.0062 Å, and c=12.9979 ű0.020 Å (95 % intervals of the laboratory means). The source of errors of outlier data was identified. The SRM project involved the certification of lattice parameters using four well-aligned single crystal diffractometers at (Bell Laboratories) Lucent Technologies and at NRC of Canada (39 ruby spheres), the quantification of the Cr content using a combined microprobe and SEM/EDS technique, and the evaluation of the mosaicity of the ruby spheres using a double-crystal spectrometry method. A confirmation of the lattice parameters was also conducted using a Guinier-Hägg camera. Systematic corrections of thermal expansion and refraction corrections were applied. These rubies– are rhombohedral, with space group R3¯c. The certified mean unit cell parameters are a=4.76080±0.00029 Å, and c=12.99568 ű0.00087 Å (expanded uncertainty). These certified lattice parameters fall well within the results of those obtained from the international round-robin study. The Guinier-Hägg transmission measurements on five samples of powdered rubies (a=4.7610 ű0.0013 Å, and c = 12.9954 ű0.0034 Å) agreed well with the values obtained from the single crystal spheres. PMID:27500067

  14. Electromedical devices test laboratories accreditation

    NASA Astrophysics Data System (ADS)

    Murad, C.; Rubio, D.; Ponce, S.; Álvarez Abri, A.; Terrón, A.; Vicencio, D.; Fascioli, E.

    2007-11-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University.

  15. Middle Atmosphere Program. Handbook for MAP. Volume 31: Reference models of trace species for the COSPAR international reference atmosphere

    NASA Technical Reports Server (NTRS)

    Keating, G. M. (Editor)

    1989-01-01

    A set of preliminary reference atmosphere models of significant trace species which play important roles in controlling the chemistry, radiation budget, and circulation patterns of the atmosphere were produced. These models of trace species distributions are considered to be reference models rather than standard models; thus, it was not crucial that they be correct in an absolute sense. These reference models can serve as a means of comparison between individual observations, as a first guess in inversion algorithms, and as an approximate representation of observations for comparison to theoretical calculations.

  16. Foreign currency-related translation complexities in cross-border healthcare applications.

    PubMed

    Kumar, Anand; Rodrigues, Jean M

    2009-01-01

    International cross-border private hospital chains need to apply the standards for foreign currency translation in order to consolidate the balance sheet and income statements. This not only exposes such chains to exchange rate fluctuations in different ways, but also creates added requirements for enterprise-level IT systems especially when they produce parameters which are used to measure the financial and operational performance of the foreign subsidiary or the parent hospital. Such systems would need to come to terms with the complexities involved in such currency-related translations in order to provide the correct data for performance benchmarking.

  17. 12 CFR 1236.4 - Failure to meet a standard; corrective plans.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of the order, agreement, or response. (d) Amendment of corrective plan. A regulated entity that is... 12 Banks and Banking 10 2014-01-01 2014-01-01 false Failure to meet a standard; corrective plans. 1236.4 Section 1236.4 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS PRUDENTIAL...

  18. 12 CFR 1236.4 - Failure to meet a standard; corrective plans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of the order, agreement, or response. (d) Amendment of corrective plan. A regulated entity that is... 12 Banks and Banking 9 2013-01-01 2013-01-01 false Failure to meet a standard; corrective plans. 1236.4 Section 1236.4 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS PRUDENTIAL...

  19. MMV in partnership: the Eurartesim® experience

    PubMed Central

    2013-01-01

    Background This case study describes how a public-private partnership between Medicines for Malaria Venture (MMV) and Sigma-Tau Industrie Farmaceutiche Riunite SpA achieved international regulatory approval for use of the fixed-dose artemisinin-based combination therapy dihydroartemisinin-piperaquine (Eurartesim®) for the treatment of malaria, enabling more widespread access to the medicine in malaria-endemic countries. Case description The combination of dihydroartemisinin and piperaquine demonstrated success in clinical trials for the treatment of malaria in Asia and Africa in the 2000s. However, as it had not been developed to international regulatory standards it was out of the reach of the majority of patients in disease-endemic countries, particularly those reliant on public healthcare systems supported by international donor funding. To overcome this, as of 2004 MMV worked in partnership with Sigma-Tau, Holleykin, Oxford University, the Institute of Tropical Medicine Antwerp, and the National Institute of Malaria Research India to develop the dihydroartemisinin-piperaquine combination to international standards. In 2011, the European Commission granted full marketing authorization to Sigma-Tau for Eurartesim. Discussion and evaluation The partnership between MMV, Sigma-Tau, and numerous other academic and industrial partners across the world, led to the successful development to EMA regulatory standards of a high-quality and highly efficacious anti-malarial treatment that otherwise would not have been possible. The dossier has also been submitted to the WHO for prequalification, and a safety statement to guide correct use of Eurartesim has been produced. In July 2012, the first delivery to a disease-endemic country was made to Cambodia, where the medicine is being used to treat patients and help counter the emergence of artemisinin resistance in the area. A paediatric dispersible formulation of Eurartesim is being developed, with the objective to submit the dossier to the EMA by the end of 2014. Conclusions The development of Eurartesim to international regulatory standards exemplifies the strengths of the product development partnership model in utilising the individual skills and expertise of partners with differing objectives to achieve a common goal. Successful uptake of Eurartesim by public health systems in malaria-endemic countries poses new challenges, which may require additional partnerships as we move forward. PMID:23782869

  20. Tuberculosis detection and the challenges of integrated care in rural China: A cross-sectional standardized patient study.

    PubMed

    Sylvia, Sean; Xue, Hao; Zhou, Chengchao; Shi, Yaojiang; Yi, Hongmei; Zhou, Huan; Rozelle, Scott; Pai, Madhukar; Das, Jishnu

    2017-10-01

    Despite recent reductions in prevalence, China still faces a substantial tuberculosis (TB) burden, with future progress dependent on the ability of rural providers to appropriately detect and refer TB patients for further care. This study (a) provides a baseline assessment of the ability of rural providers to correctly manage presumptive TB cases; (b) measures the gap between provider knowledge and practice and; (c) evaluates how ongoing reforms of China's health system-characterized by a movement toward "integrated care" and promotion of initial contact with grassroots providers-will affect the care of TB patients. Unannounced standardized patients (SPs) presenting with classic pulmonary TB symptoms were deployed in 3 provinces of China in July 2015. The SPs successfully completed 274 interactions across all 3 tiers of China's rural health system, interacting with providers in 46 village clinics, 207 township health centers, and 21 county hospitals. Interactions between providers and standardized patients were assessed against international and national standards of TB care. Using a lenient definition of correct management as at least a referral, chest X-ray or sputum test, 41% (111 of 274) SPs were correctly managed. Although there were no cases of empirical anti-TB treatment, antibiotics unrelated to the treatment of TB were prescribed in 168 of 274 interactions or 61.3% (95% CI: 55%-67%). Correct management proportions significantly higher at county hospitals compared to township health centers (OR 0.06, 95% CI: 0.01-0.25, p < 0.001) and village clinics (OR 0.02, 95% CI: 0.0-0.17, p < 0.001). Correct management in tests of knowledge administered to the same 274 physicians for the same case was 45 percentage points (95% CI: 37%-53%) higher with 24 percentage points (95% CI: -33% to -15%) fewer antibiotic prescriptions. Relative to the current system, where patients can choose to bypass any level of care, simulations suggest that a system of managed referral with gatekeeping at the level of village clinics would reduce proportions of correct management from 41% to 16%, while gatekeeping at the level of the township hospital would retain correct management close to current levels at 37%. The main limitations of the study are 2-fold. First, we evaluate the management of a one-time new patient presenting with presumptive TB, which may not reflect how providers manage repeat patients or more complicated TB presentations. Second, simulations under alternate policies require behavioral and statistical assumptions that should be addressed in future applications of this method. There were significant quality deficits among village clinics and township health centers in the management of a classic case of presumptive TB, with higher proportions of correct case management in county hospitals. Poor clinical performance does not arise only from a lack of knowledge, a phenomenon known as the "know-do" gap. Given significant deficits in quality of care, reforms encouraging first contact with lower tiers of the health system can improve efficiency only with concomitant improvements in appropriate management of presumptive TB patients in village clinics and township health centers.

  1. 77 FR 13996 - Indian Tribal Government Plans; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-08

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-133223-08] RIN 1545-BI19 Indian Tribal Government Plans; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... 12226) relating to Indian tribal government plans. FOR FURTHER INFORMATION CONTACT: Concerning the...

  2. Oxygen permeability of the pigmented material used in cosmetic daily disposable contact lenses.

    PubMed

    Galas, Stephen; Copper, Lenora L

    2016-01-01

    To evaluate the individual contributions of pigment colorant and packing solution containing polyvinyl pyrrolidone (PVP) on the oxygen permeability (Dk) of a cosmetic printed etafilcon A daily disposable contact lens packaged with PVP. The oxygen transport of a contact lens is evaluated through the central optical zone of the lens. Cosmetic printed contact lenses contain pigment colorant in the periphery or mid-periphery of the lens. Therefore, to assess the impact of cosmetic print on oxygen permeability, special lenses need to be produced that contain the colorant within the central optical zone. This technique was used to obtain multiple measurements of nonedge-corrected Dk/t of both the center pigmented lens and its nonpigmented equivalent, using a polarographic measurement described in International Organization for Standardization (ISO) 18369-4:2006(E), and the Dk derived for each measurement is corrected for edge effect. In addition, the edge-corrected Dk values of lenses made from the same monomer batch were measured. The lenses were packaged and autoclaved with and without proprietary technology which embeds PVP in the contact lens during autoclaving. The resulting Dk value of the printed lens material was then used with thickness data to generate true Dk/t profiles for a given lens power. The edge-corrected Dk of the printed etafilcon A lens with offset pigment colorant was measured to be 19.7×10 -11 (cm 2 /s) (mL O 2 /mL·mmHg) at 35°C. This was within ±20% tolerance range as specified in ISO 18369-2:2012(E) for the edge-corrected Dk of the nonpigmented etafilcon A control lens evaluated during the same session, 19.5×10 -11 (cm 2 /s) (mL O 2 /mL·mmHg). The edge-corrected Dk values of the lenses packaged with PVP (mean 20.1, standard deviation [SD] 0.3) were also within the ±20% tolerance range compared to those packaged without PVP (mean 20.0, SD 0.3). The pigment colorant and PVP embedded in the contact lens during autoclaving were not found to influence the oxygen permeability of the etafilcon A material.

  3. Congenital completely buried penis in boys: anatomical basis and surgical technique.

    PubMed

    Liu, Xing; He, Da-wei; Hua, Yi; Zhang, De-ying; Wei, Guang-hui

    2013-07-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Surgical correction of the congenital completely buried penis (CCBP) is a difficult challenge and there is no unanimous consensus about the surgical 'gold standard' and patient eligibility for surgery. In the present study, dysgenetic fundiform ligaments were found to be attached to the distal or middle shaft of the penis. This abnormality can be successfully corrected by releasing the fundiform ligament and mobilising the scrotal skin to cover the length of the penile shaft. The study shows that the paucity and traction of the penile skin and an abnormal fundiform ligament are important anatomical defects in CCBP. Dorsal curve and severe shortage of penile skin in erectile conditions are the main indications for surgical correction. To present our experience of anatomical findings for congenital completely buried penis (CCBP), which has no unanimous consensus regarding the 'gold standard' for surgical correction and patient eligibility, by providing our surgical technique and illustrations. Between February 2006 and February 2011, 22 children with a median (range) age of 4.2 (2.5-5.8) years, with CCBP underwent surgical correction by one surgeon. Toilet training and photographs of morning erections by parents were advised before surgery. The abnormal anatomical structure of buried penis during the operation was observed. The technique consisted of the release of the fundiform ligament, fixation of the subcutaneous penile skin at the base of the degloved penis, penoscrotal Z-plasty and mobilisation of the penile and scrotal skin to cover the penile shaft. In reflex erectile conditions, CCBP presents varying degrees of dorsal curve and shortage of penile skin. Dysgenetic fundiform ligaments were found to be attached to the distal or middle shaft of the penis in all patients. All wounds healed well and the cosmetic outcome was good at 6-month follow-up after the repair. The appearance of the dorsal curve in CCBP mainly results from the traction of penile dorsal skin and the abnormal attachment of the fundiform ligament to the shaft. This abnormality can be successfully corrected by releasing the abnormal fundiform ligament and mobilising scrotal skin to cover the length of the penile shaft. © 2013 BJU International.

  4. Asteroseismic modelling of solar-type stars: internal systematics from input physics and surface correction methods

    NASA Astrophysics Data System (ADS)

    Nsamba, B.; Campante, T. L.; Monteiro, M. J. P. F. G.; Cunha, M. S.; Rendle, B. M.; Reese, D. R.; Verma, K.

    2018-04-01

    Asteroseismic forward modelling techniques are being used to determine fundamental properties (e.g. mass, radius, and age) of solar-type stars. The need to take into account all possible sources of error is of paramount importance towards a robust determination of stellar properties. We present a study of 34 solar-type stars for which high signal-to-noise asteroseismic data is available from multi-year Kepler photometry. We explore the internal systematics on the stellar properties, that is, associated with the uncertainty in the input physics used to construct the stellar models. In particular, we explore the systematics arising from: (i) the inclusion of the diffusion of helium and heavy elements; and (ii) the uncertainty in solar metallicity mixture. We also assess the systematics arising from (iii) different surface correction methods used in optimisation/fitting procedures. The systematics arising from comparing results of models with and without diffusion are found to be 0.5%, 0.8%, 2.1%, and 16% in mean density, radius, mass, and age, respectively. The internal systematics in age are significantly larger than the statistical uncertainties. We find the internal systematics resulting from the uncertainty in solar metallicity mixture to be 0.7% in mean density, 0.5% in radius, 1.4% in mass, and 6.7% in age. The surface correction method by Sonoi et al. and Ball & Gizon's two-term correction produce the lowest internal systematics among the different correction methods, namely, ˜1%, ˜1%, ˜2%, and ˜8% in mean density, radius, mass, and age, respectively. Stellar masses obtained using the surface correction methods by Kjeldsen et al. and Ball & Gizon's one-term correction are systematically higher than those obtained using frequency ratios.

  5. 76 FR 18581 - Correction; Central Valley Project Improvement Act, Standard Criteria for Agricultural and Urban...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-04

    ... DEPARTMENT OF THE INTERIOR Bureau of Reclamation Correction; Central Valley Project Improvement Act, Standard Criteria for Agricultural and Urban Water Management Plans AGENCY: Bureau of Reclamation... notice in the Federal Register at 76 FR 16818 on the Central Valley Project Improvement Act Standard...

  6. 77 FR 10997 - Energy Conservation Program: Energy Conservation Standards for Distribution Transformers; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ... Conservation Program: Energy Conservation Standards for Distribution Transformers; Correction AGENCY: Office of... standards for distribution transformers. It was recently discovered that values in certain tables of the...,'' including distribution transformers. The Energy Policy Act of 1992 (EPACT 1992), Public Law 102-486, amended...

  7. 77 FR 43018 - Updating OSHA Construction Standards Based on National Consensus Standards; Head Protection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    .... OSHA-2011-0184] RIN 1218-AC65 Updating OSHA Construction Standards Based on National Consensus... Health Administration (OSHA), Department of Labor. ACTION: Notice of proposed rulemaking; correction. SUMMARY: OSHA is correcting a notice of proposed rulemaking (NPRM) with regard to the construction...

  8. SU-E-J-218: Evaluation of CT Images Created Using a New Metal Artifact Reduction Reconstruction Algorithm for Radiation Therapy Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niemkiewicz, J; Palmiotti, A; Miner, M

    2014-06-01

    Purpose: Metal in patients creates streak artifacts in CT images. When used for radiation treatment planning, these artifacts make it difficult to identify internal structures and affects radiation dose calculations, which depend on HU numbers for inhomogeneity correction. This work quantitatively evaluates a new metal artifact reduction (MAR) CT image reconstruction algorithm (GE Healthcare CT-0521-04.13-EN-US DOC1381483) when metal is present. Methods: A Gammex Model 467 Tissue Characterization phantom was used. CT images were taken of this phantom on a GE Optima580RT CT scanner with and without steel and titanium plugs using both the standard and MAR reconstruction algorithms. HU valuesmore » were compared pixel by pixel to determine if the MAR algorithm altered the HUs of normal tissues when no metal is present, and to evaluate the effect of using the MAR algorithm when metal is present. Also, CT images of patients with internal metal objects using standard and MAR reconstruction algorithms were compared. Results: Comparing the standard and MAR reconstructed images of the phantom without metal, 95.0% of pixels were within ±35 HU and 98.0% of pixels were within ±85 HU. Also, the MAR reconstruction algorithm showed significant improvement in maintaining HUs of non-metallic regions in the images taken of the phantom with metal. HU Gamma analysis (2%, 2mm) of metal vs. non-metal phantom imaging using standard reconstruction resulted in an 84.8% pass rate compared to 96.6% for the MAR reconstructed images. CT images of patients with metal show significant artifact reduction when reconstructed with the MAR algorithm. Conclusion: CT imaging using the MAR reconstruction algorithm provides improved visualization of internal anatomy and more accurate HUs when metal is present compared to the standard reconstruction algorithm. MAR reconstructed CT images provide qualitative and quantitative improvements over current reconstruction algorithms, thus improving radiation treatment planning accuracy.« less

  9. 77 FR 18929 - Seagoing Barges

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-29

    ... changes to the tables. Additionally, this correcting amendment corrects the amendatory instructions of the... flammable liquid international for-hire, except and 6. listed in part cargo in bulk.\\5\\ voyage, except those..., 3, 4, oceanographic in bulk that are flammable liquid international vessels, not 6, and 7. research...

  10. 77 FR 13996 - Determination of Governmental Plan Status; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-08

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-157714-06] RIN 1545-BG43 Determination of Governmental Plan Status; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION...) relating to the determination of governmental plans. FOR FURTHER INFORMATION CONTACT: Concerning the...

  11. Optimal Hotspots of Dynamic Surfaced-Enhanced Raman Spectroscopy for Drugs Quantitative Detection.

    PubMed

    Yan, Xiunan; Li, Pan; Zhou, Binbin; Tang, Xianghu; Li, Xiaoyun; Weng, Shizhuang; Yang, Liangbao; Liu, Jinhuai

    2017-05-02

    Surface-enhanced Raman spectroscopy (SERS) as a powerful qualitative analysis method has been widely applied in many fields. However, SERS for quantitative analysis still suffers from several challenges partially because of the absence of stable and credible analytical strategy. Here, we demonstrate that the optimal hotspots created from dynamic surfaced-enhanced Raman spectroscopy (D-SERS) can be used for quantitative SERS measurements. In situ small-angle X-ray scattering was carried out to in situ real-time monitor the formation of the optimal hotspots, where the optimal hotspots with the most efficient hotspots were generated during the monodisperse Au-sol evaporating process. Importantly, the natural evaporation of Au-sol avoids the nanoparticles instability of salt-induced, and formation of ordered three-dimensional hotspots allows SERS detection with excellent reproducibility. Considering SERS signal variability in the D-SERS process, 4-mercaptopyridine (4-mpy) acted as internal standard to validly correct and improve stability as well as reduce fluctuation of signals. The strongest SERS spectra at the optimal hotspots of D-SERS have been extracted to statistics analysis. By using the SERS signal of 4-mpy as a stable internal calibration standard, the relative SERS intensity of target molecules demonstrated a linear response versus the negative logarithm of concentrations at the point of strongest SERS signals, which illustrates the great potential for quantitative analysis. The public drugs 3,4-methylenedioxymethamphetamine and α-methyltryptamine hydrochloride obtained precise analysis with internal standard D-SERS strategy. As a consequence, one has reason to believe our approach is promising to challenge quantitative problems in conventional SERS analysis.

  12. Laser-induced breakdown spectroscopy (LIBS) analysis of calcium ions dissolved in water using filter paper substrates: an ideal internal standard for precision improvement.

    PubMed

    Choi, Daewoong; Gong, Yongdeuk; Nam, Sang-Ho; Han, Song-Hee; Yoo, Jonghyun; Lee, Yonghoon

    2014-01-01

    We report an approach for selecting an internal standard to improve the precision of laser-induced breakdown spectroscopy (LIBS) analysis for determining calcium (Ca) concentration in water. The dissolved Ca(2+) ions were pre-concentrated on filter paper by evaporating water. The filter paper was dried and analyzed using LIBS. By adding strontium chloride to sample solutions and using a Sr II line at 407.771 nm for the intensity normalization of Ca II lines at 393.366 or 396.847 nm, the analysis precision could be significantly improved. The Ca II and Sr II line intensities were mapped across the filter paper, and they showed a strong positive shot-to-shot correlation with the same spatial distribution on the filter paper surface. We applied this analysis approach for the measurement of Ca(2+) in tap, bottled, and ground water samples. The Ca(2+) concentrations determined using LIBS are in good agreement with those obtained from flame atomic absorption spectrometry. Finally, we suggest a homologous relation of the strongest emission lines of period 4 and 5 elements in groups IA and IIA based on their similar electronic structures. Our results indicate that the LIBS can be effectively applied for liquid analysis at the sub-parts per million level with high precision using a simple drying of liquid solutions on filter paper and the use of the correct internal standard elements with the similar valence electronic structure with respect to the analytes of interest.

  13. Direct megavoltage photon calibration service in Australia

    PubMed Central

    Ramanathan, G.; Oliver, C.; Cole, A.; Lye, J.; Harty, P. D.; Wright, T.; Webb, D. V.; Followill, D. S.

    2014-01-01

    The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) maintains the Australian primary standard of absorbed dose. Until recently, the standard was used to calibrate ionisation chambers only in 60Co gamma rays. These chambers are then used by radiotherapy clinics to determine linac output, using a correction factor (kQ) to take into account the different spectra of 60Co and the linac. Over the period 2010–2013, ARPANSA adapted the primary standard to work in megavoltage linac beams, and has developed a calibration service at three photon beams (6, 10 and 18 MV) from an Elekta Synergy linac. We describe the details of the new calibration service, the method validation and the use of the new calibration factors with the International Atomic Energy Agency’s TRS-398 dosimetry Code of Practice. The expected changes in absorbed dose measurements in the clinic when shifting from 60Co to the direct calibration are determined. For a Farmer chamber (model 2571), the measured chamber calibration coefficient is expected to be reduced by 0.4, 1.0 and 1.1 % respectively for these three beams when compared to the factor derived from 60Co. These results are in overall agreement with international absorbed dose standards and calculations by Muir and Rogers in 2010 of kQ factors using Monte Carlo techniques. The reasons for and against moving to the new service are discussed in the light of the requirements of clinical dosimetry. PMID:25146559

  14. FREIGHT CONTAINER LIFTING STANDARD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POWERS DJ; SCOTT MA; MACKEY TC

    2010-01-13

    This standard details the correct methods of lifting and handling Series 1 freight containers following ISO-3874 and ISO-1496. The changes within RPP-40736 will allow better reading comprehension, as well as correcting editorial errors.

  15. Absolute Spectrophotometric Calibration to 1% from the FUV through the near-IR

    NASA Astrophysics Data System (ADS)

    Finley, David

    2005-07-01

    We propose a significant improvement to the existing HST calibration. The current calibration is based on three primary DA white dwarf standards, GD 71, GD 153, and G 191-B2B. The standard fluxes are calculated using NLTE models, with effective temperatures and gravities that were derived from Balmer line fits using LTE models. We propose to improve the accuracy and internal consistency of the calibration by deriving corrected effective temperatures and gravities based on fitting the observed line profiles with updated NLTE models, and including the fit results from multiple STIS spectra, rather than the {usually} 1 or 2 ground-based spectra used previously. We will also determine the fluxes for 5 new, fainter primary or secondary standards, extending the standard V magnitude lower limit from 13.4 to 16.5, and extending the wavelength coverage from 0.1 to 2.5 micron. The goal is to achieve an overall flux accuracy of 1%, which will be needed, for example, for the upcoming supernova survey missions to measure the equation of state of the dark energy that is accelerating the expansion of the universe.

  16. Software Assists in Extensive Environmental Auditing

    NASA Technical Reports Server (NTRS)

    Callac, Christopher; Matherne, Charlie

    2002-01-01

    The Base Enivronmental Management System (BEMS) is a Web-based application program for managing and tracking audits by the Environmental Office of Stennis Space Center in conformity with standard 14001 of the International Organization for Standardization (ISO 14001). (This standard specifies requirements for an environmental-management system.) BEMS saves time by partly automating what were previously manual processes for creating audit checklists; recording and tracking audit results; issuing, tracking, and implementing corrective-action requests (CARs); tracking continuous improvements (CIs); and tracking audit results and statistics. BEMS consists on an administration module and an auditor module. As its name suggests, the administration module is used to administer the audit. It helps administrators to edit the list of audit questions; edit the list of audit locations; assign manditory questions to locations; track, approve, and edit CARs; and edit completed audits. The auditor module is used by auditors to perform audits and record audit results: It helps the auditors to create audit checklists, complete audits, view completed audits, create CARs, record and acknowledge CIs, and generate reports from audit results.

  17. Software Assists in Extensive Environmental Auditing

    NASA Technical Reports Server (NTRS)

    Callac, Christopher; Matherne, Charlie

    2003-01-01

    The Base Environmental Management System (BEMS) is a Web-based application program for managing and tracking audits by the Environmental Office of Stennis Space Center in conformity with standard 14001 of the International Organization for Standardization (ISO 14001). (This standard specifies requirements for an environmental-management system.) BEMS saves time by partly automating what were previously manual processes for creating audit checklists; recording and tracking audit results; issuing, tracking, and implementing corrective-action requests (CARs); tracking continuous improvements (CIs); and tracking audit results and statistics. BEMS consists of an administration module and an auditor module. As its name suggests, the administration module is used to administer the audit. It helps administrators to edit the list of audit questions; edit the list of audit locations; assign mandatory questions to locations; track, approve, and edit CARs; and edit completed audits. The auditor module is used by auditors to perform audits and record audit results: it helps the auditors to create audit checklists, complete audits, view completed audits, create CARs, record and acknowledge CIs, and generate reports from audit results.

  18. Software Assists in Extensive Environmental Auditing

    NASA Technical Reports Server (NTRS)

    Callac, Christopher; Matherne, Charlie; Selinsky, T.

    2002-01-01

    The Base Environmental Management System (BEMS) is a Web-based application program for managing and tracking audits by the Environmental Office of Stennis Space Center in conformity with standard 14001 of the International Organization for Standardization (ISO 14001). (This standard specifies requirements for an environmental-management system.) BEMS saves time by partly automating what were previously manual processes for creating audit checklists; recording and tracking audit results; issuing, tracking, and implementing corrective-action requests (CARs); tracking continuous improvements (CIs); and tracking audit results and statistics. BEMS consists of an administration module and an auditor module. As its name suggests, the administration module is used to administer the audit. It helps administrators to edit the list of audit questions; edit the list of audit locations; assign mandatory questions to locations; track, approve, and edit CARs; and edit completed audits. The auditor module is used by auditors to perform audits and record audit results: it helps the auditors to create audit checklists, complete audits, view completed audits, create CARs, record and acknowledge CIs, and generate reports from audit results.

  19. A generic standard additions based method to determine endogenous analyte concentrations by immunoassays to overcome complex biological matrix interference.

    PubMed

    Pang, Susan; Cowen, Simon

    2017-12-13

    We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.

  20. Corsica: A Multi-Mission Absolute Calibration Site

    NASA Astrophysics Data System (ADS)

    Bonnefond, P.; Exertier, P.; Laurain, O.; Guinle, T.; Femenias, P.

    2013-09-01

    In collaboration with the CNES and NASA oceanographic projects (TOPEX/Poseidon and Jason), the OCA (Observatoire de la Côte d'Azur) developed a verification site in Corsica since 1996, operational since 1998. CALibration/VALidation embraces a wide variety of activities, ranging from the interpretation of information from internal-calibration modes of the sensors to validation of the fully corrected estimates of the reflector heights using in situ data. Now, Corsica is, like the Harvest platform (NASA side) [14], an operating calibration site able to support a continuous monitoring with a high level of accuracy: a 'point calibration' which yields instantaneous bias estimates with a 10-day repeatability of 30 mm (standard deviation) and mean errors of 4 mm (standard error). For a 35-day repeatability (ERS, Envisat), due to a smaller time series, the standard error is about the double ( 7 mm).In this paper, we will present updated results of the absolute Sea Surface Height (SSH) biases for TOPEX/Poseidon (T/P), Jason-1, Jason-2, ERS-2 and Envisat.

  1. Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Lichte, F.E.; Meier, A.L.; Crock, J.G.

    1987-01-01

    A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.

  2. 77 FR 41048 - Health Insurance Premium Tax Credit; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... the health insurance premium tax credit enacted by the Patient Protection and Affordable Care Act and... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9590] RIN 1545-BJ82 Health Insurance Premium Tax Credit; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION...

  3. 77 FR 12226 - Indian Tribal Government Plans; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-133223-08] RIN 1545-BI19 Indian Tribal Government Plans; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... the Federal Register on Friday, February 3, 2012 (77 FR 5442) relating to Indian tribal government...

  4. 37 CFR 1.471 - Corrections and amendments during international processing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2014-07-01 2014-07-01 false Corrections and amendments during international processing. 1.471 Section 1.471 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES...

  5. 37 CFR 1.471 - Corrections and amendments during international processing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Corrections and amendments during international processing. 1.471 Section 1.471 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES...

  6. 37 CFR 1.471 - Corrections and amendments during international processing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Corrections and amendments during international processing. 1.471 Section 1.471 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES...

  7. 37 CFR 1.471 - Corrections and amendments during international processing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2013-07-01 2013-07-01 false Corrections and amendments during international processing. 1.471 Section 1.471 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES...

  8. 37 CFR 1.471 - Corrections and amendments during international processing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Corrections and amendments during international processing. 1.471 Section 1.471 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES...

  9. 76 FR 51922 - Modifications of Certain Derivative Contracts; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-109006-11] RIN 1545-BK13 Modifications of Certain Derivative Contracts; Correction AGENCY: Internal Revenue Service (IRS), Treasury... nonassigning counterparty when there is an assignment of certain derivative contracts. It was published in the...

  10. 77 FR 12514 - Determination of Governmental Plan Status; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-157714-06] RIN 1545-BG43 Determination of Governmental Plan Status; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... governmental plans. FOR FURTHER INFORMATION CONTACT: Concerning the proposed regulations, Pamela Kinard at (202...

  11. Electroweak and Higgs boson internal bremsstrahlung. General considerations for Majorana dark matter annihilation and application to MSSM neutralinos

    NASA Astrophysics Data System (ADS)

    Bringmann, Torsten; Calore, Francesca; Galea, Ahmad; Garny, Mathias

    2017-09-01

    It is well known that the annihilation of Majorana dark matter into fermions is helicity suppressed. Here, we point out that the underlying mechanism is a subtle combination of two distinct effects, and we present a comprehensive analysis of how the suppression can be partially or fully lifted by the internal bremsstrahlung of an additional boson in the final state. As a concrete illustration, we compute analytically the full amplitudes and annihilation rates of supersymmetric neutralinos to final states that contain any combination of two standard model fermions, plus one electroweak gauge boson or one of the five physical Higgs bosons that appear in the minimal supersymmetric standard model. We classify the various ways in which these three-body rates can be large compared to the two-body rates, identifying cases that have not been pointed out before. In our analysis, we put special emphasis on how to avoid the double counting of identical kinematic situations that appear for two-body and three-body final states, in particular on how to correctly treat differential rates and the spectrum of the resulting stable particles that is relevant for indirect dark matter searches. We find that both the total annihilation rates and the yields can be significantly enhanced when taking into account the corrections computed here, in particular for models with somewhat small annihilation rates at tree-level which otherwise would not be testable with indirect dark matter searches. Even more importantly, however, we find that the resulting annihilation spectra of positrons, neutrinos, gamma-rays and antiprotons differ in general substantially from the model-independent spectra that are commonly adopted, for these final states, when constraining particle dark matter with indirect detection experiments.

  12. Simultaneous mapping of water shift and B1 (WASABI)-Application to field-Inhomogeneity correction of CEST MRI data.

    PubMed

    Schuenke, Patrick; Windschuh, Johannes; Roeloffs, Volkert; Ladd, Mark E; Bachert, Peter; Zaiss, Moritz

    2017-02-01

    Together with the development of MRI contrasts that are inherently small in their magnitude, increased magnetic field accuracy is also required. Hence, mapping of the static magnetic field (B 0 ) and the excitation field (B 1 ) is not only important to feedback shim algorithms, but also for postprocess contrast-correction procedures. A novel field-inhomogeneity mapping method is presented that allows simultaneous mapping of the water shift and B 1 (WASABI) using an off-resonant rectangular preparation pulse. The induced Rabi oscillations lead to a sinc-like spectrum in the frequency-offset dimension and allow for determination of B 0 by its symmetry axis and of B 1 by its oscillation frequency. Stability of the WASABI method with regard to the influences of T 1 , T 2 , magnetization transfer, and repetition time was investigated and its convergence interval was verified. B 0 and B 1 maps obtained simultaneously by means of WASABI in the human brain at 3 T and 7 T can compete well with maps obtained by standard methods. Finally, the method was applied successfully for B 0 and B 1 correction of chemical exchange saturation transfer MRI (CEST-MRI) data of the human brain. The proposed WASABI method yields a novel simultaneous B 0 and B 1 mapping within 1 min that is robust and easy to implement. Magn Reson Med 77:571-580, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. 77 FR 22472 - Energy Conservation Program: Energy Conservation Standards for Certain External Power Supplies...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-16

    ... Conservation Program: Energy Conservation Standards for Certain External Power Supplies; Correction AGENCY... external power supplies to re-insert a table that had been inadvertently deleted by a technical amendment... standards for all Class A external power supplies to meet. DATES: This correction is effective April 16...

  14. 77 FR 42988 - Updating OSHA Construction Standards Based on National Consensus Standards; Head Protection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    .... OSHA-2011-0184] RIN 1218-AC65 Updating OSHA Construction Standards Based on National Consensus... Administration (OSHA), Department of Labor. ACTION: Direct final rule; correction. SUMMARY: OSHA is correcting a... confusion resulting from a drafting error. OSHA published the DFR on June 22, 2012 (77 FR 37587). OSHA also...

  15. International Standards for Properties and Performance of Advanced Ceramics - 30 years of Excellence

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.; Helfinstine, John; Quinn, George D.; Gonczy, Stephen T.

    2016-01-01

    Mechanical and physical properties/performance of brittle bodies (e.g., advanced ceramics and glasses) can be difficult to measure correctly unless the proper techniques are used. For three decades, ASTM Committee C28 on Advanced Ceramics, has developed numerous full-consensus standards (e.g., test methods, practices, guides, terminology) to measure various properties and performance of a monolithic and composite ceramics and coatings that, in some cases, may be applicable to glasses. These standards give the "what, how, how not, why, why not, etc." for many mechanical, physical, thermal, properties and performance of advanced ceramics. Use of these standards provides accurate, reliable, repeatable and complete data. Involvement in ASTM Committee C28 has included users, producers, researchers, designers, academicians, etc. who write, continually update, and validate through round robin test programmes, more than 45 standards in the 30 years since the Committee's inception in 1986. Included in this poster is a pictogram of the ASTM Committee C28 standards and how to obtain them either as i) individual copies with full details or ii) a complete collection in one volume. A listing of other ASTM committees of interest is included. In addition, some examples of the tangible benefits of standards for advanced ceramics are employed to demonstrate their practical application.

  16. 77 FR 23117 - Rigging Equipment for Material Handling Construction Standard; Correction and Technical Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ...OSHA is correcting its sling standard for construction titled ``Rigging Equipment for Material Handling'' by removing the rated capacity tables and making minor, nonsubstantive revisions to the regulatory text.

  17. 55 FR 14037 Correction to the National Emission Standards for Hazardous Air Pollutants

    EPA Pesticide Factsheets

    Correction to the National Emission Standards for Hazardous Air Pollutants; Benzene Emissions From Maleic Anhydride Plants, Ethylbenzene/Styrene Plants, Benzene Storage Vessels, Benzene Equipment Leaks, and Coke Byproduct Recovery Plants.

  18. 77 FR 14342 - Polyvinyl Alcohol From Taiwan: Correction to Notice of Opportunity To Request Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-583-841] Polyvinyl Alcohol From Taiwan: Correction to Notice of Opportunity To Request Administrative Review AGENCY: Import Administration, International Trade Administration, Department of Commerce. FOR FURTHER INFORMATION CONTACT: Dustin Ross, AD/CVD Operations, Office 1, Import...

  19. 77 FR 48111 - Branded Prescription Drug Fee; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 51 [REG-112805-10] RIN 1545-BJ39 Branded Prescription Drug Fee; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice..., August 6, 2012 (77 FR 46653) relating to the branded prescription drug fee imposed by the Affordable Care...

  20. 76 FR 2852 - Guidance on Reporting Interest Paid to Nonresident Aliens; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-18

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1 and 31 [REG-146097-09] RIN 1545-BJ01 Guidance on Reporting Interest Paid to Nonresident Aliens; Correction AGENCY: Internal Revenue.... offices of certain financial institutions and paid to nonresident alien individuals. FOR FURTHER...

  1. 76 FR 30052 - Controlled Groups; Deferral of Losses; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-24

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-118761-09] RIN 1545-BI92 Controlled Groups; Deferral of Losses; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... deferred losses on the sale or exchange of property between members of a controlled group. FOR FURTHER...

  2. 76 FR 708 - Electronic Funds Transfer of Depository Taxes; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-06

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1, 31, 40, and 301 [TD 9507] RIN 1545-BJ13 Electronic Funds Transfer of Depository Taxes; Correction AGENCY: Internal Revenue Service... Electronic Funds Transfer (EFT). The temporary and final regulations provide rules under which depositors...

  3. 76 FR 709 - Electronic Funds Transfer of Depository Taxes; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-06

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 40 and 301 [TD 9507] RIN 1545-BJ13 Electronic Funds Transfer of Depository Taxes; Correction AGENCY: Internal Revenue Service (IRS...) providing guidance relating to Federal tax deposits (FTDs) by Electronic Funds Transfer (EFT). The temporary...

  4. 75 FR 52485 - Electronic Funds Transfer of Depository Taxes; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-26

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1, 31, 40, and 301 [REG-153340-09] RIN 1545-BJ13 Electronic Funds Transfer of Depository Taxes; Correction AGENCY: Internal Revenue... to Federal tax deposits (FTDs) by Electronic Funds Transfer (EFT). FOR FURTHER INFORMATION CONTACT...

  5. 75 FR 49379 - Correction to Internal Citation of “Extremely Flammable Solid” and “Flammable Solid”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ... Flammable Solid'' and ``Flammable Solid'' AGENCY: Consumer Product Safety Commission. ACTION: Final rule... to correct internal citations to the definitions of ``extremely flammable solid'' and ``flammable solid'' in our regulations. DATES: This rule is effective on August 13, 2010. FOR FURTHER INFORMATION...

  6. An Improved Correction for Range Restricted Correlations Under Extreme, Monotonic Quadratic Nonlinearity and Heteroscedasticity.

    PubMed

    Culpepper, Steven Andrew

    2016-06-01

    Standardized tests are frequently used for selection decisions, and the validation of test scores remains an important area of research. This paper builds upon prior literature about the effect of nonlinearity and heteroscedasticity on the accuracy of standard formulas for correcting correlations in restricted samples. Existing formulas for direct range restriction require three assumptions: (1) the criterion variable is missing at random; (2) a linear relationship between independent and dependent variables; and (3) constant error variance or homoscedasticity. The results in this paper demonstrate that the standard approach for correcting restricted correlations is severely biased in cases of extreme monotone quadratic nonlinearity and heteroscedasticity. This paper offers at least three significant contributions to the existing literature. First, a method from the econometrics literature is adapted to provide more accurate estimates of unrestricted correlations. Second, derivations establish bounds on the degree of bias attributed to quadratic functions under the assumption of a monotonic relationship between test scores and criterion measurements. New results are presented on the bias associated with using the standard range restriction correction formula, and the results show that the standard correction formula yields estimates of unrestricted correlations that deviate by as much as 0.2 for high to moderate selectivity. Third, Monte Carlo simulation results demonstrate that the new procedure for correcting restricted correlations provides more accurate estimates in the presence of quadratic and heteroscedastic test score and criterion relationships.

  7. Development of a drift-correction procedure for a direct-reading spectrometer

    NASA Technical Reports Server (NTRS)

    Chapman, G. B., II; Gordon, W. A.

    1977-01-01

    A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

  8. MRI simulation: end-to-end testing for prostate radiation therapy using geometric pelvic MRI phantoms

    NASA Astrophysics Data System (ADS)

    Sun, Jidi; Dowling, Jason; Pichler, Peter; Menk, Fred; Rivest-Henault, David; Lambert, Jonathan; Parker, Joel; Arm, Jameen; Best, Leah; Martin, Jarad; Denham, James W.; Greer, Peter B.

    2015-04-01

    To clinically implement MRI simulation or MRI-alone treatment planning requires comprehensive end-to-end testing to ensure an accurate process. The purpose of this study was to design and build a geometric phantom simulating a human male pelvis that is suitable for both CT and MRI scanning and use it to test geometric and dosimetric aspects of MRI simulation including treatment planning and digitally reconstructed radiograph (DRR) generation. A liquid filled pelvic shaped phantom with simulated pelvic organs was scanned in a 3T MRI simulator with dedicated radiotherapy couch-top, laser bridge and pelvic coil mounts. A second phantom with the same external shape but with an internal distortion grid was used to quantify the distortion of the MR image. Both phantoms were also CT scanned as the gold-standard for both geometry and dosimetry. Deformable image registration was used to quantify the MR distortion. Dose comparison was made using a seven-field IMRT plan developed on the CT scan with the fluences copied to the MR image and recalculated using bulk electron densities. Without correction the maximum distortion of the MR compared with the CT scan was 7.5 mm across the pelvis, while this was reduced to 2.6 and 1.7 mm by the vendor’s 2D and 3D correction algorithms, respectively. Within the locations of the internal organs of interest, the distortion was <1.5 and <1 mm with 2D and 3D correction algorithms, respectively. The dose at the prostate isocentre calculated on CT and MRI images differed by 0.01% (1.1 cGy). Positioning shifts were within 1 mm when setup was performed using MRI generated DRRs compared to setup using CT DRRs. The MRI pelvic phantom allows end-to-end testing of the MRI simulation workflow with comparison to the gold-standard CT based process. MRI simulation was found to be geometrically accurate with organ dimensions, dose distributions and DRR based setup within acceptable limits compared to CT.

  9. Limits of linearity and detection for some drugs of abuse.

    PubMed

    Needleman, S B; Romberg, R W

    1990-01-01

    The limits of linearity (LOL) and detection (LOD) are important factors in establishing the reliability of an analytical procedure for accurately assaying drug concentrations in urine specimens. Multiple analyses of analyte over an extended range of concentrations provide a measure of the ability of the analytical procedure to correctly identify known quantities of drug in a biofluid matrix. Each of the seven drugs of abuse gives linear analytical responses from concentrations at or near their LOD to concentrations several-fold higher than those generally encountered in the drug screening laboratory. The upper LOL exceeds the Department of Navy (DON) cutoff values by factors of approximately 2 to 160. The LOD varies from 0.4 to 5.0% of the DON cutoff value for each drug. The limit of quantitation (LOQ) is calculated as the LOD + 7 SD. The range for LOL is greater for drugs analyzed with deuterated internal standards compared with those using conventional internal standards. For THC acid, cocaine, PCP, and morphine, LOLs are 8 to 160-fold greater than the defined cutoff concentrations. For the other drugs, the LOL's are only 2 to 4-fold greater than the defined cutoff concentrations.

  10. Enhancing reproducibility: Failures from Reproducibility Initiatives underline core challenges.

    PubMed

    Mullane, Kevin; Williams, Michael

    2017-08-15

    Efforts to address reproducibility concerns in biomedical research include: initiatives to improve journal publication standards and peer review; increased attention to publishing methodological details that enable experiments to be reconstructed; guidelines on standards for study design, implementation, analysis and execution; meta-analyses of multiple studies within a field to synthesize a common conclusion and; the formation of consortia to adopt uniform protocols and internally reproduce data. Another approach to addressing reproducibility are Reproducibility Initiatives (RIs), well-intended, high-profile, systematically peer-vetted initiatives that are intended to replace the traditional process of scientific self-correction. Outcomes from the RIs reported to date have questioned the usefulness of this approach, particularly when the RI outcome differs from other independent self-correction studies that have reproduced the original finding. As a failed RI attempt is a single outcome distinct from the original study, it cannot provide any definitive conclusions necessitating additional studies that the RI approach has neither the ability nor intent of conducting making it a questionable replacement for self-correction. A failed RI attempt also has the potential to damage the reputation of the author of the original finding. Reproduction is frequently confused with replication, an issue that is more than semantic with the former denoting "similarity" and the latter an "exact copy" - an impossible outcome in research because of known and unknown technical, environmental and motivational differences between the original and reproduction studies. To date, the RI framework has negatively impacted efforts to improve reproducibility, confounding attempts to determine whether a research finding is real. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. 49 CFR 325.75 - Ground surface correction factors. 1

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Ground surface correction factors. 1 325.75... MOTOR CARRIER NOISE EMISSION STANDARDS Correction Factors § 325.75 Ground surface correction factors. 1... account both the distance correction factors contained in § 325.73 and the ground surface correction...

  12. 49 CFR 325.75 - Ground surface correction factors. 1

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Ground surface correction factors. 1 325.75... MOTOR CARRIER NOISE EMISSION STANDARDS Correction Factors § 325.75 Ground surface correction factors. 1... account both the distance correction factors contained in § 325.73 and the ground surface correction...

  13. 76 FR 59897 - Branded Prescription Drug Fee; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-28

    ... Prescription Drug Fee; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correcting... branded prescription drugs. This fee was enacted by section 9008 of the Patient Protection and Affordable...: This correction is effective on September 28, 2011 and applies to any fee on branded prescription drug...

  14. Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.

    PubMed

    Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari

    2017-06-01

    Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.

  15. 40 CFR 60.33b - Emission guidelines for municipal waste combustor metals, acid gases, organics, and nitrogen oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... from a designated facility is 400 micrograms per dry standard cubic meter, corrected to 7 percent... discharged to the atmosphere from a designated facility is 27 milligrams per dry standard cubic meter... standard cubic meter, corrected to 7 percent oxygen. (ii) [Reserved] (iii) The emission limit for opacity...

  16. Bias Corrections for Standardized Effect Size Estimates Used with Single-Subject Experimental Designs

    ERIC Educational Resources Information Center

    Ugille, Maaike; Moeyaert, Mariola; Beretvas, S. Natasha; Ferron, John M.; Van den Noortgate, Wim

    2014-01-01

    A multilevel meta-analysis can combine the results of several single-subject experimental design studies. However, the estimated effects are biased if the effect sizes are standardized and the number of measurement occasions is small. In this study, the authors investigated 4 approaches to correct for this bias. First, the standardized effect…

  17. Mental health screening and evaluation within prisons.

    PubMed

    Metzner, J L; Miller, R D; Kleinsasser, D

    1994-01-01

    Current national standards and/or guidelines for correctional mental health care programs emphasize the importance of various levels of mental health screening and evaluation that should be performed by qualified personnel on all inmates as part of the admission process to a prison. The authors describe the results of a study that included data from all 50 state departments of corrections regarding prison mental health screening and evaluation models. The vast majority of states appear to have adopted some variation of the most recognized guidelines and/or standards (e.g., American Psychiatric Association, National Commission on Correctional Health Care, American Public Health Association) concerning correctional health care systems. Results are also provided concerning the use of standardized psychological tests and informed consent issues.

  18. 78 FR 13709 - Advisory Committee on Construction Safety and Health (ACCSH)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... corrections to the Cranes and Derricks standards. DATES: ACCSH meeting: The ACCSH will meet from 1 to 4:00 p.m... Proposed technical amendments and corrections OSHA's Cranes and Derricks standards (29 CFR part 1926...

  19. 76 FR 59897 - Branded Prescription Drug Fee; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-28

    ... Prescription Drug Fee; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correction to... branded prescription drugs. This fee was enacted by section 9008 of the Patient Protection and Affordable...: This correction is effective on September 28, 2011 and applies to any fee on branded prescription drug...

  20. An engineering model 30 cm ion thruster

    NASA Technical Reports Server (NTRS)

    Poeschel, R. L.; King, H. J.; Schnelker, D. E.

    1973-01-01

    Thruster development at Hughes Research Laboratories and NASA Lewis Research Center has brought the 30-cm mercury bombardment ion thruster to the state of an engineering model. This thruster has been designed to have sufficient internal strength for direct mounting on gimbals, to weigh 7.3 kg, to operate with a corrected overall efficiency of 71%, and to have 10,000 hours lifetime. Subassemblies, such as the ion optical system, isolators, etc., have been upgraded to meet launch qualification standards. This paper presents a summary of the design specifications and performance characteristics which define the interface between the thruster module and the remainder of the propulsion system.

  1. 76 FR 7757 - Guidance on Reporting Interest Paid to Nonresident Aliens; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1 and 31 [REG-146097-09] RIN 1545-BJ01 Guidance on Reporting Interest Paid to Nonresident Aliens; Correction AGENCY: Internal Revenue... maintained at U.S. offices of certain financial institutions and paid to nonresident alien individuals. FOR...

  2. 75 FR 76940 - Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1 and 301 [REG-100194-10] RIN 1545-BJ52 Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic Media; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correction to notice of...

  3. 78 FR 38430 - Notice of Meeting of Advisory Committee on International Law

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-26

    ... DEPARTMENT OF STATE [Public Notice 8351] Notice of Meeting of Advisory Committee on International Law Correction In notice document 2013-13719, appearing on page 34702 in the issue of Monday, June 10, 2013, make the following correction: In the third column, in the last paragraph, the entry ``(202-776...

  4. 76 FR 71450 - Deduction for Qualified Film and Television Production Costs; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-18

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9552] RIN 1545-BJ24 Deduction for Qualified Film and Television Production Costs; Correction AGENCY: Internal Revenue Service... Register on Wednesday, October 19, 2011 (76 FR 64816) relating to deductions for the cost of producing film...

  5. 78 FR 13575 - Coverage of Certain Preventive Services Under the Affordable Care Act; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 54 [REG-120391-10] RIN 1545-BJ60 Coverage of Certain Preventive Services Under the Affordable Care Act; Correction AGENCY: Internal Revenue... Protection and Affordable Care Act, as amended, and incorporated into the Employee Retirement Income Security...

  6. 76 FR 27609 - Reduction of Foreign Tax Credit Limitation Categories Under Section 904(d); Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-12

    ... Reduction of Foreign Tax Credit Limitation Categories Under Section 904(d); Correction AGENCY: Internal... foreign tax credit limitation categories under section 904(d) of the Internal Revenue Code. DATES: This... in and Losses With Respect to the Pre-2007 Separate Category for High Withholding Tax Interest...

  7. 76 FR 39341 - Encouraging New Markets Tax Credit Non-Real Estate Investments; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-114206-11] RIN 1545-BK21 Encouraging New Markets Tax Credit Non-Real Estate Investments; Correction AGENCY: Internal Revenue Service... how the new markets tax credit program may be amended to encourage non-real estate investments. FOR...

  8. 76 FR 39343 - New Markets Tax Credit Non-Real Estate Investments; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [REG-101826-11] RIN 1545-BK04 New Markets Tax Credit Non-Real Estate Investments; Correction AGENCY: Internal Revenue Service (IRS... Tuesday, June 7, 2011 (76 FR 32882) modifying the new markets tax credit program to facilitate and...

  9. 75 FR 69626 - Certain Steel Grating From the People's Republic of China: Notice of Correction to the Final...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-947] Certain Steel Grating From the People's Republic of China: Notice of Correction to the Final Determination of Sales at Less Than Fair Value and Antidumping Duty Order AGENCY: Import Administration, International Trade Administration...

  10. Particle mobility size spectrometers: harmonization of technical standards and data structure to facilitate high quality long-term observations of atmospheric particle number size distributions

    NASA Astrophysics Data System (ADS)

    Wiedensohler, A.; Birmili, W.; Nowak, A.; Sonntag, A.; Weinhold, K.; Merkel, M.; Wehner, B.; Tuch, T.; Pfeifer, S.; Fiebig, M.; Fjäraa, A. M.; Asmi, E.; Sellegri, K.; Depuy, R.; Venzac, H.; Villani, P.; Laj, P.; Aalto, P.; Ogren, J. A.; Swietlicki, E.; Roldin, P.; Williams, P.; Quincey, P.; Hüglin, C.; Fierz-Schmidhauser, R.; Gysel, M.; Weingartner, E.; Riccobono, F.; Santos, S.; Grüning, C.; Faloon, K.; Beddows, D.; Harrison, R. M.; Monahan, C.; Jennings, S. G.; O'Dowd, C. D.; Marinoni, A.; Horn, H.-G.; Keck, L.; Jiang, J.; Scheckman, J.; McMurry, P. H.; Deng, Z.; Zhao, C. S.; Moerman, M.; Henzing, B.; de Leeuw, G.

    2010-12-01

    Particle mobility size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers) or SMPS (Scanning Mobility Particle Sizers) have found a wide application in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. This article results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research). Under controlled laboratory conditions, the number size distribution from 20 to 200 nm determined by mobility size spectrometers of different design are within an uncertainty range of ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. Instruments with identical design agreed within ±3% in the peak number concentration when all settings were done carefully. Technical standards were developed for a minimum requirement of mobility size spectrometry for atmospheric aerosol measurements. Technical recommendations are given for atmospheric measurements including continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyser. In cooperation with EMEP (European Monitoring and Evaluation Program), a new uniform data structure was introduced for saving and disseminating the data within EMEP. This structure contains three levels: raw data, processed data, and final particle size distributions. Importantly, we recommend reporting raw measurements including all relevant instrument parameters as well as a complete documentation on all data transformation and correction steps. These technical and data structure standards aim to enhance the quality of long-term size distribution measurements, their comparability between different networks and sites, and their transparency and traceability back to raw data.

  11. High level waste storage tank farms/242-A evaporator standards/requirements identification document phase 1 assessment corrective actions/compliance schedule approval report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biebesheimer, E.

    This document, the Standards/Requirements Identification Document (S/RID) Phase I Assessment Corrective Actions/Compliance Schedule Approval Report for the subject facility, contains the corrective actions required to bring the facility into compliance as a result of an Administrative Assessment to determine whether S/RID requirements are fully addressed by existing policies, plans or procedures. These actions are delineated in the Compliance Schedule Approvals which also contain; noncompliances, risks, compensatory measures, schedules for corrective actions, justifications for approval, and resource impacts.

  12. Framework for Automation of Hazard Log Management on Large Critical Projects

    NASA Astrophysics Data System (ADS)

    Vinerbi, Lorenzo; Babu, Arun P.

    2016-08-01

    Hazard log is a database of all risk management activities in a project. Maintaining its correctness and consistency on large safety/mission critical projects involving multiple vendors, suppliers, and partners is critical and challenging. IBM DOORS is one of the popular tool used for hazard management in space applications. However, not all stake- holders are familiar with it. Also, It is not always feasible to expect all stake-holders to provide correct and consistent hazard data.The current work describes the process and tools to simplify the process of hazard data collection on large projects. It demonstrates how the collected data from all stake-holders is merged to form the hazard log while ensuring data consistency and correctness.The data provided by all parties are collected using a template containing scripts. The scripts check for mistakes based on internal standards of company in charge of hazard management. The collected data is then subjected to merging in DOORS, which also contain scripts to check and import data to form the hazard log. The proposed tool has been applied to a mission critical project, and has been found to save time and reduce the number of mistakes while creating the hazard log. The use of automatic checks paves the way for correct tracking of risk and hazard analysis activities for large critical projects.

  13. Machine vs. human translation of SNOMED CT terms.

    PubMed

    Schulz, Stefan; Bernhardt-Melischnig, Johannes; Kreuzthaler, Markus; Daumke, Philipp; Boeker, Martin

    2013-01-01

    In the context of past and current SNOMED CT translation projects we compare three kinds of SNOMED CT translations from English to German by: (t1) professional medical translators; (t2) a free Web-based machine translation service; (t3) medical students. 500 SNOMED CT fully specified names from the (English) International release were randomly selected. Based on this, German translations t1, t2, and t3 were generated. A German and an Austrian physician rated the translations for linguistic correctness and content fidelity. Kappa for inter-rater reliability was 0.4 for linguistic correctness and 0.23 for content fidelity. Average ratings of linguistic correctness did not differ significantly between human translation scenarios. Content fidelity was rated slightly better for student translators compared to professional translators. Comparing machine to human translation, the linguistic correctness differed about 0.5 scale units in favour of the human translation and about 0.25 regarding content fidelity, equally in favour of the human translation. The results demonstrate that low-cost translation solutions of medical terms may produce surprisingly good results. Although we would not recommend low-cost translation for producing standardized preferred terms, this approach can be useful for creating additional language-specific entry terms. This may serve several important use cases. We also recommend testing this method to bootstrap a crowdsourcing process, by which term translations are gathered, improved, maintained, and rated by the user community.

  14. Relationships between digit ratio (2D:4D) and basketball performance in Australian men.

    PubMed

    Frick, Nathan A; Hull, Melissa J; Manning, John T; Tomkinson, Grant R

    2017-05-06

    To investigate relationships between the digit ratio (2D:4D) and competitive basketball performance in Australian men. Using an observational cross-sectional design a total of 221 Australian basketball players who competed in the Olympic Games, International Basketball Federation World Championships/Cup, Australian National Basketball League, Central Australian Basketball League or socially had their 2D:4Ds measured. Analysis of variance was used to assess differences in mean 2D:4Ds between men playing at different competitive standards, with relationships between 2D:4Ds and basketball game-related statistics assessed using Pearson's product moment correlations in men playing at a single competitive standard. There were significant differences between competitive standards for the left 2D:4D following Bonferroni correction, but not for the right 2D:4D, with basketballers who achieved higher competitive standards tending to have lower left 2D:4Ds. No important correlations between 2D:4D and basketball game-related statistics were found, with correlations typically negligible. This study indicated that the 2D:4D can discriminate between basketballers competing at different standards, but not between basketballers within a single competitive standard using objective game-related statistics. © 2016 Wiley Periodicals, Inc.

  15. New frontiers in coral geochronology: advancing the state of the art

    NASA Astrophysics Data System (ADS)

    Thompson, William G.

    2010-05-01

    New developments in mass spectrometry and a better understanding of open-system processes are ushering in a new era of precision and accuracy in coral geochronology. An effort is underway to develop a uniform set of reference materials and reporting standards to assure age comparability between laboratories and eliminate inter-laboratory and age interpretation biases. PALSEA is a PAGES/IMAGES working group that aims to extract information about ice sheet response to temperature change by examining the history of sea during past interglacials. As reef-building corals are one of the primary archives of past sea levels, the U-series coral dating community is well represented in this group. During workshop discussions, it became clear that further progress on the sea level problem requires engaging the coral dating community in a cooperative standardization effort. Improvements in analytical precision continue to extend the potential precision and range of the U-Th chronometer. As a result, assuring comparability of ages reported by different labs becomes a crucial issue. Ideally, all measurements should be traceable to the same set of reference standards. Unfortunately, internationally recognized standards are not currently available. A widely used U/Th uraninite standard, HU-1, is no longer be suitable, as different aliquots have different isotope ratios and the assumption of radioactive equilibrium no longer appears valid when measured at current levels of precision. The time is ripe for the development of new reference standards. A strategy for their production and distribution has been initiated in collaboration with the NERC Isotope Geosciences Laboratory, UK, and drawing on the experiences of the EARTHTIME initiative (http://www.earth-time.org). Quaternary sea level data is presently scattered across the scientific literature with widely varying reporting formats, screening and correction criteria, and decay constants. Stratigraphic information is often incomplete, and elevations are not tied to consistent benchmarks. It would be highly desirable to compile existing data in a uniform format that can be made available to the wider community, and to adopt a uniform set of standards for future data reporting. While best practices for sample screening and/or age correction are still keenly debated, reported ages depend heavily on assumptions about the 234U/238U history of seawater over the last 800 thousand years. A standard history of ocean 234U/238U for quality and correction criteria, with associated error estimates, would make ages reported by different labs more directly comparable. Data reduction and archiving software has been developed as part of the EARTHTIME project, and discussions are underway to adapt this software for the U-Th chronometer. Standardized reporting through data reduction and databasing software has great potential to make U-series dating of coral sea-level indicators more useful and accessible to the wider paleoclimate community.

  16. 40 CFR 192.04 - Corrective action.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Corrective action. 192.04 Section 192.04 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS HEALTH AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for...

  17. 78 FR 67210 - Charging Standard Administrative Fees for Nonprogram-Related Information; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-08

    ... SOCIAL SECURITY ADMINISTRATION [Docket No. SSA-2012-0026] Charging Standard Administrative Fees for Nonprogram-Related Information; Correction AGENCY: Social Security Administration. ACTION: Notice... Social Security Administration published a document in the Federal Register of September 18, 2013...

  18. Optimization of post-run corrections for water stable isotope measurements by laser spectroscopy

    NASA Astrophysics Data System (ADS)

    van Geldern, Robert; Barth, Johannes A. C.

    2013-04-01

    Light stable isotope analyses of hydrogen and oxygen of water are used in numerous aquatic studies from various scientific fields. The advantage of using stable isotope ratios is that water molecules serve as ubiquitous and already present natural tracers. Traditionally, the samples were analyzed in the laboratory by isotope ratio mass spectrometry (IRMS). Within recent years these analyses have been revolutionized by the development of new isotope ratio laser spectroscopy (IRIS) systems that are said to be cheaper, more robust and mobile compared to IRMS. Although easier to operate, laser systems also need thorough calibration with international reference materials and raw data need correction for analytical effects. A major issue in systems that use liquid injection via a vaporizer module is the memory effect, i.e. the carry-over from the previous analyzed sample in a sequence. This study presents an optimized and simple post-run correction procedure for liquid water injection developed for a Picarro water analyzer. The Excel(TM) template will rely exclusively on standard features implemented in MS Office without the need to run macros, additional code written in Visual Basic for Applications (VBA) or to use a database-related software such as MS Access or SQL Server. These protocols will maximize precision, accuracy and sample throughput via an efficient memory correction. The number of injections per unknown sample can be reduced to 4 or less. This procedure meets the demands of faster throughput with reduced costs per analysis. Procedures were verified by an international proficiency test and traditional IRMS techniques. The template is available free for scientific use from the corresponding author or the journals web site (van Geldern and Barth, 2012). References van Geldern, R. and Barth, J.A.C. (2012) Limnol. Oceanogr. Methods 10:1024-1036 [doi: 10.4319/lom.2012.10.1024

  19. Asteroseismic modelling of solar-type stars: internal systematics from input physics and surface correction methods

    NASA Astrophysics Data System (ADS)

    Nsamba, B.; Campante, T. L.; Monteiro, M. J. P. F. G.; Cunha, M. S.; Rendle, B. M.; Reese, D. R.; Verma, K.

    2018-07-01

    Asteroseismic forward modelling techniques are being used to determine fundamental properties (e.g. mass, radius, and age) of solar-type stars. The need to take into account all possible sources of error is of paramount importance towards a robust determination of stellar properties. We present a study of 34 solar-type stars for which high signal-to-noise asteroseismic data are available from multiyear Kepler photometry. We explore the internal systematics on the stellar properties, that is associated with the uncertainty in the input physics used to construct the stellar models. In particular, we explore the systematics arising from (i) the inclusion of the diffusion of helium and heavy elements; (ii) the uncertainty in solar metallicity mixture; and (iii) different surface correction methods used in optimization/fitting procedures. The systematics arising from comparing results of models with and without diffusion are found to be 0.5 per cent, 0.8 per cent, 2.1 per cent, and 16 per cent in mean density, radius, mass, and age, respectively. The internal systematics in age are significantly larger than the statistical uncertainties. We find the internal systematics resulting from the uncertainty in solar metallicity mixture to be 0.7 per cent in mean density, 0.5 per cent in radius, 1.4 per cent in mass, and 6.7 per cent in age. The surface correction method by Sonoi et al. and Ball & Gizon's two-term correction produce the lowest internal systematics among the different correction methods, namely, ˜1 per cent, ˜1 per cent, ˜2 per cent, and ˜8 per cent in mean density, radius, mass, and age, respectively. Stellar masses obtained using the surface correction methods by Kjeldsen et al. and Ball & Gizon's one-term correction are systematically higher than those obtained using frequency ratios.

  20. Impact of new clock technologies on the stability and accuracy of the International Atomic Time TAI.

    NASA Astrophysics Data System (ADS)

    Thomas, C.

    1997-05-01

    The BIPM Time Section is in charge of the generation of the reference time scales TAI and UTC. Both time scales are obtained in deferred-time by combining the data front a number of atomic clocks spread worldwide. The accuracy of TAI is estimated by the departure between the duration of the TAI scale interval and the SI second as produced on the rotating geoid by primary frequency standards. It is now possible to estimate TAI accuracy through the combination of results obtained from six different primary standards: LPTF-FO1, PTB CS1, PTB CS2, PTB CS3, NIST-7, and SU MCsR 102, all corrected for the black-body radiation shift. This led to a mean departure of the TAI scale interval of +2.0×10-14s over 1995, known with a relative uncertainty of 0.5×10-14(1σ).

  1. Monitoring of stability of ASG-EUPOS network coordinates

    NASA Astrophysics Data System (ADS)

    Figurski, M.; Szafranek, K.; Wrona, M.

    2009-04-01

    ASG-EUPOS (Active Geodetic Network - European Position Determination System) is the national system of precise satellite positioning in Poland, which increases a density of regional and global GNSS networks and is widely used by public administration, national institutions, entrepreneurs and citizens (especially surveyors). In near future ASG-EUPOS is to take role of main national network. Control of proper activity of stations and realization of ETRS'89 is a necessity. User of the system needs to be sure that observations quality and coordinates accuracy are high enough. Coordinates of IGS (International GNSS Service) and EPN (European Permanent Network) stations are precisely determined and any changes are monitored all the time. Observations are verified before they are archived in regional and global databases. The same applies to ASG-EUPOS. This paper concerns standardization of GNSS observations from different stations (uniform adjustment), examination of solutions correctness according to IGS and EPN standards and stability of solutions and sites activity

  2. Excise tax avoidance: the case of state cigarette taxes.

    PubMed

    DeCicca, Philip; Kenkel, Donald; Liu, Feng

    2013-12-01

    We conduct an applied welfare economics analysis of cigarette tax avoidance. We develop an extension of the standard formula for the optimal Pigouvian corrective tax to incorporate the possibility that consumers avoid the tax by making purchases in nearby lower tax jurisdictions. To provide a key parameter for our formula, we estimate a structural endogenous switching regression model of border-crossing and cigarette prices. In illustrative calculations, we find that for many states, after taking into account tax avoidance the optimal tax is at least 20% smaller than the standard Pigouvian tax that simply internalizes external costs. Our empirical estimate that tax avoidance strongly responds to the price differential is the main reason for this result. We also use our results to examine the benefits of replacing avoidable state excise taxes with a harder-to-avoid federal excise tax on cigarettes. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Excise Tax Avoidance: The Case of State Cigarette Taxes

    PubMed Central

    DeCicca, Philip; Kenkel, Donald; Liu, Feng

    2013-01-01

    We conduct an applied welfare economics analysis of cigarette tax avoidance. We develop an extension of the standard formula for the optimal Pigouvian corrective tax to incorporate the possibility that consumers avoid the tax by making purchases in nearby lower-tax jurisdictions. To provide a key parameter for our formula, we estimate a structural endogenous switching regression model of border-crossing and cigarette prices. In illustrative calculations, we find that for many states, after taking into account tax avoidance the optimal tax is at least 20 percent smaller than the standard Pigouvian tax that simply internalizes external costs. Our empirical estimate that tax avoidance strongly responds to the price differential is the main reason for this result. We also use our results to examine the benefits of replacing avoidable state excise taxes with a harder-to-avoid federal excise tax on cigarettes. PMID:24140760

  4. NASA Audit Follow-up Handbook

    NASA Technical Reports Server (NTRS)

    1990-01-01

    This NASA Audit Follow-up Handbook is issued pursuant to the requirements of the Office of Management and Budget (OMB) Circular A-50, Audit Follow-up, dated September 29, 1982. It sets forth policy, uniform performance standards, and procedural guidance to NASA personnel for use when considering reports issued by the Office of Inspector General (OIG), other executive branch audit organizations, the Defense Contract Audit Agency (DCAA), and the General Accounting Office (GAO). It is intended to: specify principal roles; strengthen the procedures for management decisions (resolution) on audit findings and corrective action on audit report recommendations; emphasize the importance of monitoring agreed upon corrective actions to assure actual accomplishment; and foster the use of audit reports as effective tools of management. A flow chart depicting the NASA audit and management decision process is in Appendix A. This handbook is a controlled handbook issued in loose-leaf form and will be revised by page changes. Additional copies for internal use may be obtained through normal distribution channels.

  5. Renormalization of the Higgs sector in the triplet model

    NASA Astrophysics Data System (ADS)

    Aoki, Mayumi; Kanemura, Shinya; Kikuchi, Mariko; Yagyu, Kei

    2012-08-01

    We study radiative corrections to the mass spectrum and the triple Higgs boson coupling in the model with an additional Y = 1 triplet field. In this model, the vacuum expectation value for the triplet field is strongly constrained from the electroweak precision data, under which characteristic mass spectrum appear at the tree level; i.e., mH++2 - mH+2 ≃ mH+2 - mA2 and mA2 ≃ mH2, where the CP-even (H), the CP-odd (A) and the doubly-charged (H±±) as well as the singly-charged (H±) Higgs bosons are the triplet-like. We evaluate how the tree-level formulae are modified at the one-loop level. The hhh coupling for the standard model-like Higgs boson (h) is also calculated at the one-loop level. One-loop corrections to these quantities can be large enough for identification of the model by future precision data at the LHC or the International Linear Collider.

  6. Correcting sensitivity drift during long-term multi-element signal measurements by solid sampling-ETV-ICP-MS.

    PubMed

    Martin-Esteban, A; Slowikowski, B; Grobecker, K H

    2004-06-17

    Solid sampling-electrothermal vaporisation-inductively coupled plasma-mass spectrometry (SS-ETV-ICP-MS) is an attractive technique for the direct simultaneous determination of trace elements in solid samples and especially in long-term studies (i.e. assessment of the homogeneity of reference materials). However, during these studies a downward drift in the instrument sensitivity has been observed due likely to deposits on the sampling and skimmer cones and on the ion lens of the mass spectrometer. Accordingly, in this paper, several means of correcting and/or suppressing sensitivity drift are proposed and evaluated for the monitoring of Cd, Cu, Hg, Mn, Pb, Sb, Se, Sn, Tl, U and V in different reference materials of inorganic and organic (biological) origin. From that studies, the combination of the use of the argon dimer as internal standard together with a modification in the ETV-ICP connection tube seems to be the best mean of getting stable sensitivity during at least 60 consecutive ETV runs.

  7. VizieR Online Data Catalog: LAMOST DR2 catalogs (Luo+, 2016)

    NASA Astrophysics Data System (ADS)

    Luo, A.-L.; Zhao, Y.-H.; Zhao, G.; Deng, L.-C.; Liu, X.-W.; Jing, Y.-P.; Wang, G.; Zhang, H.-T.; Shi, J.-R.; Cui, X.-Q.; Chu, Y.-Q.; Li, G.-P.; Bai, Z.-R.; Wu, Y.; Cai, Y.; Cao, S.-Y.; Cao, Z.-H.; Carlin, J. L.; Chen, H.-Y.; Chen, J.-J.; Chen, K.-X.; Chen, L.; Chen, X.-L.; Chen, X.-Y.; Chen, Y.; Christlieb, N.; Chu, J.-R.; Cui, C.-Z.; Dong, Y.-Q.; Du, B.; Fan, D.-W.; Feng, L.; Fu, J.-N.; Gao, P.; Gong, X.-F.; Gu, B.-Z.; Guo, Y.-X.; Han, Z.-W.; He, B.-L.; Hou, J.-L.; Hou, Y.-H.; Hou, W.; Hu, H.-Z.; Hu, N.-S.; Hu, Z.-W.; Huo, Z.-Y.; Jia, L.; Jiang, F.-H.; Jiang, X.; Jiang, Z.-B.; Jin, G.; Kong, X.; Kong, X.; Lei, Y.-J.; Li, A.-H.; Li, C.-H.; Li, G.-W.; Li, H.-N.; Li, J.; Li, Q.; Li, S.; Li, S.-S.; Li, X.-N.; Li, Y.; Li, Y.-B.; Li, Y.-P.; Liang, Y.; Lin, C.-C.; Liu, C.; Liu, G.-R.; Liu, G.-Q.; Liu, Z.-G.; Lu, W.-Z.; Luo, Y.; Mao, Y.-D.; Newberg, H.; Ni, J.-J.; Qi, Z.-X.; Qi, Y.-J.; Shen, S.-Y.; Shi, H.-M.; Song, J.; Song, Y.-H.; Su, D.-Q.; Su, H.-J.; Tang, Z.-H.; Tao, Q.-S.; Tian, Y.; Wang, D.; Wang, D.-Q.; Wang, F.-F.; Wang, G.-M.; Wang, H.; Wang, H.-C.; Wang, J.; Wang, J.-N.; Wang, J.-L.; Wang, J.-P.; Wang, J.-X.; Wang, L.; Wang, M.-X.; Wang, S.-G.; Wang, S.-Q.; Wang, X.; Wang, Y.-N.; Wang, Y.; Wang, Y.-F.; Wang, Y.-F.; Wei, P.; Wei, M.-Z.; Wu, H.; Wu, K.-F.; Wu, X.-B.; Wu, Y.-Z.; Xing, X.-Z.; Xu, L.-Z.; Xu, X.-Q.; Xu, Y.; Yan, T.-S.; Yang, D.-H.; Yang, H.-F.; Yang, H.-Q.; Yang, M.; Yao, Z.-Q.; Yu, Y.; Yuan, H.; Yuan, H.-B.; Yuan, H.-L.; Yuan, W.-M.; Zhai, C.; Zhang, E.-P.; Zhang, H.-W.; Zhang, J.-N.; Zhang, L.-P.; Zhang, W.; Zhang, Y.; Zhang, Y.-X.; Zhang, Z.-C.; Zhao, M.; Zhou, F.; Zhou, X.; Zhu, J.; Zhu, Y.-T.; Zou, S.-C.; Zuo, F.

    2016-11-01

    There are a couple of corrections been made in this releasing: Recalculated all the errors of Teff, Logg, Fe/H and rv in the AFGK catalog. Refer to the DR2 paper (in preparation) for details. Compare to the previous internal releasing, some extra spectra has been added into this version of releasing: STAR from 3,779,597 to 3,843,597, increased 63,923; GALAXY from 37,665 to 47,036, increased 9,371; QSO from 8,633 to 13,262, increased 4,629. The major contribution to this increasing is that we applied a new method to reduce the data which previously was abandoned due to lack of standard stars with high enough S/N. Refer to the paper 'LAMOST Spectrograph Response Curves: Stability and Application to flux calibration' (in preparation) for details. There are also a small amount of increasing is due to the correction of fiber flag, and to the eye check work, etc. (5 data files).

  8. Special electronic distance meter calibration for precise engineering surveying industrial applications

    NASA Astrophysics Data System (ADS)

    Braun, Jaroslav; Štroner, Martin; Urban, Rudolf

    2015-05-01

    All surveying instruments and their measurements suffer from some errors. To refine the measurement results, it is necessary to use procedures restricting influence of the instrument errors on the measured values or to implement numerical corrections. In precise engineering surveying industrial applications the accuracy of the distances usually realized on relatively short distance is a key parameter limiting the resulting accuracy of the determined values (coordinates, etc.). To determine the size of systematic and random errors of the measured distances were made test with the idea of the suppression of the random error by the averaging of the repeating measurement, and reducing systematic errors influence of by identifying their absolute size on the absolute baseline realized in geodetic laboratory at the Faculty of Civil Engineering CTU in Prague. The 16 concrete pillars with forced centerings were set up and the absolute distances between the points were determined with a standard deviation of 0.02 millimetre using a Leica Absolute Tracker AT401. For any distance measured by the calibrated instruments (up to the length of the testing baseline, i.e. 38.6 m) can now be determined the size of error correction of the distance meter in two ways: Firstly by the interpolation on the raw data, or secondly using correction function derived by previous FFT transformation usage. The quality of this calibration and correction procedure was tested on three instruments (Trimble S6 HP, Topcon GPT-7501, Trimble M3) experimentally using Leica Absolute Tracker AT401. By the correction procedure was the standard deviation of the measured distances reduced significantly to less than 0.6 mm. In case of Topcon GPT-7501 is the nominal standard deviation 2 mm, achieved (without corrections) 2.8 mm and after corrections 0.55 mm; in case of Trimble M3 is nominal standard deviation 3 mm, achieved (without corrections) 1.1 mm and after corrections 0.58 mm; and finally in case of Trimble S6 is nominal standard deviation 1 mm, achieved (without corrections) 1.2 mm and after corrections 0.51 mm. Proposed procedure of the calibration and correction is in our opinion very suitable for increasing of the accuracy of the electronic distance measurement and allows the use of the common surveying instrument to achieve uncommonly high precision.

  9. SU-F-T-69: Correction Model of NIPAM Gel and Presage for Electron and Proton PDD Measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, C; Lin, C; Tu, P

    Purpose: The current standard equipment for proton PDD measurement is multilayer-parallel-ion-chamber. Disadvantage of multilayer-parallel-ion-chamber is expensive and complexity manipulation. NIPAM-gel and Presage are options for PDD measurement. Due to different stopping power, the result of NIPAM-gel and Presage need to be corrected. This study aims to create a correction model for NIPAM-gel and Presage PDD measurement. Methods: Standard water based PDD profiles of electron 6MeV, 12MeV, and proton 90MeV were acquired. Electron PDD profile after 1cm thickness of NIPAM-gel added on the top of water was measured. Electron PDD profile with extra 1cm thickness of solid water, PTW RW3, wasmore » measured. The distance shift among standard PDD, NIPAM-gel PDD, and solid water PDD at R50% was compared and water equivalent thickness correction factor (WET) was calculated. Similar process was repeated. WETs for electron with Presage, proton with NIPAM-gel, and proton with Presage were calculated. PDD profiles of electron and proton with NIPAM-gel and Presage columns were corrected with each WET. The corrected profiles were compared with standard profiles. Results: WET for electron 12MeV with NIPAM-gel was 1.135, and 1.034 for electron 12Mev with Presage. After correction, PDD profile matched to the standard profile at the fall-off range well. The difference at R50% was 0.26mm shallower and 0.39mm deeper. The same WET was used to correct electron 6MeV profile. Energy independence of electron WET was observed. The difference at R50% was 0.17mm deeper for NIPAM-gel and 0.54mm deeper for Presage. WET for proton 90MeV with NIPAM-gel was 1.056. The difference at R50% was 0.37 deeper. Quenching effect at Bragg peak was revealed. The underestimated dose percentage at Bragg peak was 27%. Conclusion: This correction model can be used to modify PDD profile with depth error within 1mm. With this correction model, NIPAM-gel and Presage can be practical at PDD profile measurement.« less

  10. Multidrug-resistant, extensively drug-resistant and pandrug-resistant bacteria: an international expert proposal for interim standard definitions for acquired resistance.

    PubMed

    Magiorakos, A-P; Srinivasan, A; Carey, R B; Carmeli, Y; Falagas, M E; Giske, C G; Harbarth, S; Hindler, J F; Kahlmeter, G; Olsson-Liljequist, B; Paterson, D L; Rice, L B; Stelling, J; Struelens, M J; Vatopoulos, A; Weber, J T; Monnet, D L

    2012-03-01

    Many different definitions for multidrug-resistant (MDR), extensively drug-resistant (XDR) and pandrug-resistant (PDR) bacteria are being used in the medical literature to characterize the different patterns of resistance found in healthcare-associated, antimicrobial-resistant bacteria. A group of international experts came together through a joint initiative by the European Centre for Disease Prevention and Control (ECDC) and the Centers for Disease Control and Prevention (CDC), to create a standardized international terminology with which to describe acquired resistance profiles in Staphylococcus aureus, Enterococcus spp., Enterobacteriaceae (other than Salmonella and Shigella), Pseudomonas aeruginosa and Acinetobacter spp., all bacteria often responsible for healthcare-associated infections and prone to multidrug resistance. Epidemiologically significant antimicrobial categories were constructed for each bacterium. Lists of antimicrobial categories proposed for antimicrobial susceptibility testing were created using documents and breakpoints from the Clinical Laboratory Standards Institute (CLSI), the European Committee on Antimicrobial Susceptibility Testing (EUCAST) and the United States Food and Drug Administration (FDA). MDR was defined as acquired non-susceptibility to at least one agent in three or more antimicrobial categories, XDR was defined as non-susceptibility to at least one agent in all but two or fewer antimicrobial categories (i.e. bacterial isolates remain susceptible to only one or two categories) and PDR was defined as non-susceptibility to all agents in all antimicrobial categories. To ensure correct application of these definitions, bacterial isolates should be tested against all or nearly all of the antimicrobial agents within the antimicrobial categories and selective reporting and suppression of results should be avoided. © 2011 European Society of Clinical Microbiology and Infectious Diseases. No claim to original US government works.

  11. Vitamin B1 and B6 method harmonization: comparison of performance between laboratories enrolled in the RCPA Quality Assurance Program.

    PubMed

    Hoad, Kirsten E; Johnson, Lambro A; Woollard, Gerald A; Walmsley, Trevor A; Briscoe, Scott; Jolly, Lisa M; Gill, Janice P; Greaves, Ronda F

    2013-06-01

    The RCPA Quality Assurance Program (RCPA QAP) offers monthly proficiency testing for vitamins A, B1, B6, β-carotene, C and E to laboratories worldwide. A review of the results submitted for the whole blood vitamin B1/B6 sub-program revealed a wide dispersion. Here we describe the results of a methodology survey for vitamins B1 and B6. A questionnaire was sent to thirteen laboratories. Eleven laboratories were returning QAP results for vitamin B1 (thiamine diphosphate) and five were returning results for vitamin B6 (pyridoxal-5-phosphate). All nine respondents provided a clinical service for vitamins B1 and B6. HPLC with fluorescence detection was the most common method principle. For vitamin B1, six respondents used a commercial assay whilst three used in-house methods; whole blood was the matrix for all. For vitamin B6, five respondents used commercial assays and four used in-house assays. The choice of matrix for vitamin B6 varied with three respondents using whole blood and five using plasma for analysis. Sample preparation incorporated protein precipitation and derivatization steps. An internal standard was employed in sample preparation by only one survey respondent. The immediate result of this survey was the incorporation of plasma vitamin B6 into the RCPA QAP vitamin program. The absence of an internal standard in current vitamin B1 and B6 assays is a likely contributor to the wide dispersion of results seen in this program. We recommend kit manufacturers and laboratories investigate the inclusion of internal standards to correct the variability that may occur during processing. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Measurement of dissolved organic matter fluorescense in aquatic environments: An interlaboratory comparison

    USGS Publications Warehouse

    Murphy, Kathleen R.; Butler, Kenna D.; Spencer, Robert G. M.; Stedmon, Colin A.; Boehme, Jennifer R.; Aiken, George R.

    2010-01-01

    The fluorescent properties of dissolved organic matter (DOM) are often studied in order to infer DOM characteristics in aquatic environments, including source, quantity, composition, and behavior. While a potentially powerful technique, a single widely implemented standard method for correcting and presenting fluorescence measurements is lacking, leading to difficulties when comparing data collected by different research groups. This paper reports on a large-scale interlaboratory comparison in which natural samples and well-characterized fluorophores were analyzed in 20 laboratories in the U.S., Europe, and Australia. Shortcomings were evident in several areas, including data quality-assurance, the accuracy of spectral correction factors used to correct EEMs, and the treatment of optically dense samples. Data corrected by participants according to individual laboratory procedures were more variable than when corrected under a standard protocol. Wavelength dependency in measurement precision and accuracy were observed within and between instruments, even in corrected data. In an effort to reduce future occurrences of similar problems, algorithms for correcting and calibrating EEMs are described in detail, and MATLAB scripts for implementing the study's protocol are provided. Combined with the recent expansion of spectral fluorescence standards, this approach will serve to increase the intercomparability of DOM fluorescence studies.

  13. Progressing beyond SLMTA: Are internal audits and corrective action the key drivers of quality improvement?

    PubMed

    Maina, Robert N; Mengo, Doris M; Mohamud, Abdikher D; Ochieng, Susan M; Milgo, Sammy K; Sexton, Connie J; Moyo, Sikhulile; Luman, Elizabeth T

    2014-01-01

    Kenya has implemented the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme to facilitate quality improvement in medical laboratories and to support national accreditation goals. Continuous quality improvement after SLMTA completion is needed to ensure sustainability and continue progress toward accreditation. Audits were conducted by qualified, independent auditors to assess the performance of five enrolled laboratories using the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist. End-of-programme (exit) and one year post-programme (surveillance) audits were compared for overall score, star level (from zero to five, based on scores) and scores for each of the 12 Quality System Essential (QSE) areas that make up the SLIPTA checklist. All laboratories improved from exit to surveillance audit (median improvement 38 percentage points, range 5-45 percentage points). Two laboratories improved from zero to one star, two improved from zero to three stars and one laboratory improved from three to four stars. The lowest median QSE scores at exit were: internal audit; corrective action; and occurrence management and process improvement (< 20%). Each of the 12 QSEs improved substantially at surveillance audit, with the greatest improvement in client management and customer service, internal audit and information management (≥ 50 percentage points). The two laboratories with the greatest overall improvement focused heavily on the internal audit and corrective action QSEs. Whilst all laboratories improved from exit to surveillance audit, those that focused on the internal audit and corrective action QSEs improved substantially more than those that did not; internal audits and corrective actions may have acted as catalysts, leading to improvements in other QSEs. Systematic identification of core areas and best practices to address them is a critical step toward strengthening public medical laboratories.

  14. Progressing beyond SLMTA: Are internal audits and corrective action the key drivers of quality improvement?

    PubMed Central

    Mengo, Doris M.; Mohamud, Abdikher D.; Ochieng, Susan M.; Milgo, Sammy K.; Sexton, Connie J.; Moyo, Sikhulile; Luman, Elizabeth T.

    2014-01-01

    Background Kenya has implemented the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme to facilitate quality improvement in medical laboratories and to support national accreditation goals. Continuous quality improvement after SLMTA completion is needed to ensure sustainability and continue progress toward accreditation. Methods Audits were conducted by qualified, independent auditors to assess the performance of five enrolled laboratories using the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist. End-of-programme (exit) and one year post-programme (surveillance) audits were compared for overall score, star level (from zero to five, based on scores) and scores for each of the 12 Quality System Essential (QSE) areas that make up the SLIPTA checklist. Results All laboratories improved from exit to surveillance audit (median improvement 38 percentage points, range 5–45 percentage points). Two laboratories improved from zero to one star, two improved from zero to three stars and one laboratory improved from three to four stars. The lowest median QSE scores at exit were: internal audit; corrective action; and occurrence management and process improvement (< 20%). Each of the 12 QSEs improved substantially at surveillance audit, with the greatest improvement in client management and customer service, internal audit and information management (≥ 50 percentage points). The two laboratories with the greatest overall improvement focused heavily on the internal audit and corrective action QSEs. Conclusion Whilst all laboratories improved from exit to surveillance audit, those that focused on the internal audit and corrective action QSEs improved substantially more than those that did not; internal audits and corrective actions may have acted as catalysts, leading to improvements in other QSEs. Systematic identification of core areas and best practices to address them is a critical step toward strengthening public medical laboratories. PMID:29043193

  15. 40 CFR 192.33 - Corrective action programs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Corrective action programs. 192.33 Section 192.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS HEALTH AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for...

  16. 78 FR 6809 - U.S. Healthcare Trade Mission to Russia; Moscow and St. Petersburg, June 3-7, 2013; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-31

    ... DEPARTMENT OF COMMERCE International Trade Administration U.S. Healthcare Trade Mission to Russia; Moscow and St. Petersburg, June 3-7, 2013; Correction AGENCY: International Trade Administration... Register of December 4, 2012 regarding the U.S. Healthcare Trade Mission to Russia June 3-7, 2013. The...

  17. 75 FR 57261 - Certain Frozen Fish Fillets From the Socialist Republic of Vietnam: Correction of Date for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-20

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-552-801] Certain Frozen Fish Fillets From the Socialist Republic of Vietnam: Correction of Date for the Extension of Time Limit for Preliminary Results of the Seventh Antidumping Duty New Shipper Reviews AGENCY: Import Administration, International Trade Administration, Department of...

  18. A systematic evaluation of contemporary impurity correction methods in ITS-90 aluminium fixed point cells

    NASA Astrophysics Data System (ADS)

    da Silva, Rodrigo; Pearce, Jonathan V.; Machin, Graham

    2017-06-01

    The fixed points of the International Temperature Scale of 1990 (ITS-90) are the basis of the calibration of standard platinum resistance thermometers (SPRTs). Impurities in the fixed point material at the level of parts per million can give rise to an elevation or depression of the fixed point temperature of order of millikelvins, which often represents the most significant contribution to the uncertainty of SPRT calibrations. A number of methods for correcting for the effect of impurities have been advocated, but it is becoming increasingly evident that no single method can be used in isolation. In this investigation, a suite of five aluminium fixed point cells (defined ITS-90 freezing temperature 660.323 °C) have been constructed, each cell using metal sourced from a different supplier. The five cells have very different levels and types of impurities. For each cell, chemical assays based on the glow discharge mass spectroscopy (GDMS) technique have been obtained from three separate laboratories. In addition a series of high quality, long duration freezing curves have been obtained for each cell, using three different high quality SPRTs, all measured under nominally identical conditions. The set of GDMS analyses and freezing curves were then used to compare the different proposed impurity correction methods. It was found that the most consistent corrections were obtained with a hybrid correction method based on the sum of individual estimates (SIE) and overall maximum estimate (OME), namely the SIE/Modified-OME method. Also highly consistent was the correction technique based on fitting a Scheil solidification model to the measured freezing curves, provided certain well defined constraints are applied. Importantly, the most consistent methods are those which do not depend significantly on the chemical assay.

  19. Evaluation of intensity drift correction strategies using MetaboDrift, a normalization tool for multi-batch metabolomics data.

    PubMed

    Thonusin, Chanisa; IglayReger, Heidi B; Soni, Tanu; Rothberg, Amy E; Burant, Charles F; Evans, Charles R

    2017-11-10

    In recent years, mass spectrometry-based metabolomics has increasingly been applied to large-scale epidemiological studies of human subjects. However, the successful use of metabolomics in this context is subject to the challenge of detecting biologically significant effects despite substantial intensity drift that often occurs when data are acquired over a long period or in multiple batches. Numerous computational strategies and software tools have been developed to aid in correcting for intensity drift in metabolomics data, but most of these techniques are implemented using command-line driven software and custom scripts which are not accessible to all end users of metabolomics data. Further, it has not yet become routine practice to assess the quantitative accuracy of drift correction against techniques which enable true absolute quantitation such as isotope dilution mass spectrometry. We developed an Excel-based tool, MetaboDrift, to visually evaluate and correct for intensity drift in a multi-batch liquid chromatography - mass spectrometry (LC-MS) metabolomics dataset. The tool enables drift correction based on either quality control (QC) samples analyzed throughout the batches or using QC-sample independent methods. We applied MetaboDrift to an original set of clinical metabolomics data from a mixed-meal tolerance test (MMTT). The performance of the method was evaluated for multiple classes of metabolites by comparison with normalization using isotope-labeled internal standards. QC sample-based intensity drift correction significantly improved correlation with IS-normalized data, and resulted in detection of additional metabolites with significant physiological response to the MMTT. The relative merits of different QC-sample curve fitting strategies are discussed in the context of batch size and drift pattern complexity. Our drift correction tool offers a practical, simplified approach to drift correction and batch combination in large metabolomics studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Assessments of higher-order ionospheric effects on GPS coordinate time series: A case study of CMONOC with longer time series

    NASA Astrophysics Data System (ADS)

    Jiang, Weiping; Deng, Liansheng; Zhou, Xiaohui; Ma, Yifang

    2014-05-01

    Higher-order ionospheric (HIO) corrections are proposed to become a standard part for precise GPS data analysis. For this study, we deeply investigate the impacts of the HIO corrections on the coordinate time series by implementing re-processing of the GPS data from Crustal Movement Observation Network of China (CMONOC). Nearly 13 year data are used in our three processing runs: (a) run NO, without HOI corrections, (b) run IG, both second- and third-order corrections are modeled using the International Geomagnetic Reference Field 11 (IGRF11) to model the magnetic field, (c) run ID, the same with IG but dipole magnetic model are applied. Both spectral analysis and noise analysis are adopted to investigate these effects. Results show that for CMONOC stations, HIO corrections are found to have brought an overall improvement. After the corrections are applied, the noise amplitudes decrease, with the white noise amplitudes showing a more remarkable variation. Low-latitude sites are more affected. For different coordinate components, the impacts vary. The results of an analysis of stacked periodograms show that there is a good match between the seasonal amplitudes and the HOI corrections, and the observed variations in the coordinate time series are related to HOI effects. HOI delays partially explain the seasonal amplitudes in the coordinate time series, especially for the U component. The annual amplitudes for all components are decreased for over one-half of the selected CMONOC sites. Additionally, the semi-annual amplitudes for the sites are much more strongly affected by the corrections. However, when diplole model is used, the results are not as optimistic as IGRF model. Analysis of dipole model indicate that HIO delay lead to the increase of noise amplitudes, and that HIO delays with dipole model can generate false periodic signals. When dipole model are used in modeling HIO terms, larger residual and noise are brought in rather than the effective improvements.

  1. Characterization of a customized calibration unit for continuous measurements of the isotopic composition of water vapor

    NASA Astrophysics Data System (ADS)

    Moro, Giovanni; Zannoni, Daniele; Dreossi, Giuliano; Stenni, Barbara

    2017-04-01

    The objective of this work is the development, standardization and creation of a method to carry out continuous measurement of oxygen and hydrogen isotopic composition of the atmospheric water vapor using a wavelength-scanned cavity ring down spectroscopy (WS-CRDS) instrument produced by Picarro, L1102-i model. Some technical improvements of the standard instrument configuration have been made to create three different inlet gas lines: a "standard" line, a calibration line and a line connected with the external sampler. The calibration line is composed of a syringe-pump that continuously injects standard water into a steel tee heated at the temperature of 170°C and flushed with dry nitrogen gas. In this way, instantaneous and complete vaporization of the standard water takes place. The resulting steam is characterized by a well-defined composition in δD e δ18O values. To allow comparison with other international data, we have characterized the individual instrumental response to variation of the isotopic composition of the water vapor. Several humidity-isotope response functions (6000-26000 ppmv) have been estimated with three different internal standards (0.35‰ -8.75‰ -29.11‰ and -40.28‰ for δ18O; 2.31‰ -58.91‰ -222.19‰ and -317.78‰ for δD). Moreover, we have measured the instrumental drift at regular time intervals to apply the opportune corrections to instrument data. The setup has been tested using a 3.5 day continuous measurements carried out with the Picarro sampling the water vapor outside our campus in Venice and parallel sampling using the classical cryogenic trapping procedure, obtaining excellent results. Furthermore, our analysis technique has given good results for the standards with values which are similar to those obtained with the isotope ratio mass spectrometry (IRMS) technique.

  2. SU-F-I-13: Correction Factor Computations for the NIST Ritz Free Air Chamber for Medium-Energy X Rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergstrom, P

    Purpose: The National Institute of Standards and Technology (NIST) uses 3 free-air chambers to establish primary standards for radiation dosimetry at x-ray energies. For medium-energy × rays, the Ritz free-air chamber is the main measurement device. In order to convert the charge or current collected by the chamber to the radiation quantities air kerma or air kerma rate, a number of correction factors specific to the chamber must be applied. Methods: We used the Monte Carlo codes EGSnrc and PENELOPE. Results: Among these correction factors are the diaphragm correction (which accounts for interactions of photons from the x-ray source inmore » the beam-defining diaphragm of the chamber), the scatter correction (which accounts for the effects of photons scattered out of the primary beam), the electron-loss correction (which accounts for electrons that only partially expend their energy in the collection region), the fluorescence correction (which accounts for ionization due to reabsorption ffluorescence photons and the bremsstrahlung correction (which accounts for the reabsorption of bremsstrahlung photons). We have computed monoenergetic corrections for the NIST Ritz chamber for the 1 cm, 3 cm and 7 cm collection plates. Conclusion: We find good agreement with other’s results for the 7 cm plate. The data used to obtain these correction factors will be used to establish air kerma and it’s uncertainty in the standard NIST x-ray beams.« less

  3. The 1 km AVHRR global land data set: first stages in implementation

    USGS Publications Warehouse

    Eidenshink, J.C.; Faundeen, J.L.

    1994-01-01

    The global land 1 km data set project represents an international effort to acquire, archive, process, and distribute 1 km AVHRR data of the entire global land surface in order to meet the needs of the international science community. A network of 26 high resolution picture transmission (HRPT) stations, along with data recorded by the National Oceanic and Atmospheric Administration (NOAA), has been acquiring daily global land coverage since 1 April 1992. A data set of over 30000 AVHRR images has been archived and made available for distribution by the United States Geological Survey, EROS Data Center and the European Space Agency. Under the guidance of the International Geosphere Biosphere programme, processing standards for the AVHRR data have been developed for calibration, atmospheric correction, geometric registration, and the production of global 10-day maximum normalized difference vegetation index (NDVI) composites. The major uses of the composites are related to the study of surface vegetation cover. A prototype 10-day composite was produced for the period of 21–30 June 1992. Production of an 18-month time series of 10-day composites is underway.

  4. The Reach and Limitation of the ADA and its Integration Mandate: Implications for the Successful Reentry of Individuals with Mental Disabilities in a Correctional Population.

    PubMed

    Dlugacz, Henry A; Droubi, Luna

    2017-03-01

    This article argues that the ADA and its integration mandate, informed by international standards, should extend to incarcerated individuals with mental disabilities who reenter society, as they are at highly elevated risk for unnecessary segregation in institutions such as homeless shelters or hospitals or through reincarceration. An understanding of the precise services needed to prevent these strongly related but distinct variants of institutionalization requires a robust and continuing research agenda. In discussing the breadth of the ADA, we explore its history, interpretations of its application in a variety of contexts with respect to vulnerable populations and integration, and enforcement. We also turn to international approaches to integration mandates as they apply to reentry. By interpreting the domestic and international principles that create the context for integration we hope to have provided a resource for future application of the ADA integration in the context of prisoner reentry. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Higgs boson mass in the standard model at two-loop order and beyond

    DOE PAGES

    Martin, Stephen P.; Robertson, David G.

    2014-10-01

    We calculate the mass of the Higgs boson in the standard model in terms of the underlying Lagrangian parameters at complete 2-loop order with leading 3-loop corrections. A computer program implementing the results is provided. The program also computes and minimizes the standard model effective potential in Landau gauge at 2-loop order with leading 3-loop corrections.

  6. Effect of modified bridge exercise on trunk muscle activity in healthy adults: a cross sectional study.

    PubMed

    Yoon, Jeong-Oh; Kang, Min-Hyeok; Kim, Jun-Seok; Oh, Jae-Seop

    This is a cross-sectional study. University research laboratory. Fifteen healthy adults (mean age: 27.47 years) volunteered for this study. The individuals performed standard bridge exercise and modified bridge exercises with right leg-lift (single-leg-lift bridge exercise, single-leg-lift bridge exercise on an unstable surface, and single-leg-lift hip abduction bridge exercise). During the bridge exercises, electromyography of the rectus abdominis, internal oblique, erector spinae, and multifidus muscles was recorded using a wireless surface electromyography system. Two-way repeated-measures analysis of variance (exercise by side) with post hoc pairwise comparisons using Bonferroni correction was used to compare the electromyography data collected from each muscle. Bilateral internal oblique muscle activities showed significantly greater during single-leg-lift bridge exercise (95% confidence interval: right internal oblique=-8.99 to -1.08, left internal oblique=-6.84 to -0.10), single-leg-lift bridge exercise on an unstable surface (95% confidence interval: right internal oblique=-7.32 to -1.78, left internal oblique=-5.34 to -0.99), and single-leg-lift hip abduction bridge exercise (95% confidence interval: right internal oblique=-17.13 to -0.89, left internal oblique=-8.56 to -0.60) compared with standard bridge exercise. Bilateral rectus abdominis showed greater electromyography activity during single-leg-lift bridge exercise on an unstable surface (95% confidence interval: right rectus abdominis=-9.33 to -1.13, left rectus abdominis=-4.80 to -0.64) and single-leg-lift hip abduction bridge exercise (95% confidence interval: right rectus abdominis=-14.12 to -1.84, left rectus abdominis=-6.68 to -0.16) compared with standard bridge exercise. In addition, the right rectus abdominis muscle activity was greater during single-leg-lift hip abduction bridge exercise compared with single-leg-lift bridge exercise on an unstable surface (95% confidence interval=-7.51 to -0.89). For erector spinae, muscle activity was greater in right side compared with left side during all exercises (95% confidence interval: standard bridge exercise=0.19-4.53, single-leg-lift bridge exercise=0.24-10.49, single-leg-lift bridge exercise on an unstable surface=0.74-8.55, single-leg-lift hip abduction bridge exercise=0.47-11.43). There was no significant interaction and main effect for multifidus. Adding hip abduction and unstable conditions to bridge exercises may be useful strategy to facilitate the co-activation of trunk muscles. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  7. Spatiotemporal variation of radon and carbon dioxide concentrations in an underground quarry: coupled processes of natural ventilation, barometric pumping and internal mixing.

    PubMed

    Perrier, Frédéric; Richon, Patrick

    2010-04-01

    Radon-222 and carbon dioxide concentrations have been measured during several years at several points in the atmosphere of an underground limestone quarry located at a depth of 18 m in Vincennes, near Paris, France. Both concentrations showed a seasonal cycle. Radon concentration varied from 1200 to 2000 Bq m(-3) in summer to about 800-1400 Bq m(-3) in winter, indicating winter ventilation rates varying from 0.6 to 2.5 x 10(-6) s(-1). Carbon dioxide concentration varied from 0.9 to 1.0% in summer, to about 0.1-0.3% in winter. Radon concentration can be corrected for natural ventilation using temperature measurements. The obtained model also accounts for the measured seasonal variation of carbon dioxide. After correction, radon concentrations still exhibit significant temporal variation, mostly associated with the variation of atmospheric pressure, with coupling coefficients varying from -7 to -26 Bq m(-3) hPa(-1). This variation can be accounted for using a barometric pumping model, coupled with natural ventilation in winter, and including internal mixing as well. After correction, radon concentrations exhibit residual temporal variation, poorly correlated between different points, with standard deviations varying from 3 to 6%. This study shows that temporal variation of radon concentrations in underground cavities can be understood to a satisfactory level of detail using non-linear and time-dependent modelling. It is important to understand the temporal variation of radon concentrations and the limitations in their modelling to monitor the properties of natural or artificial underground settings, and to be able to assess the existence of new processes, for example associated with the preparatory phases of volcanic eruptions or earthquakes. Copyright 2009 Elsevier Ltd. All rights reserved.

  8. Correcting the Standard Errors of 2-Stage Residual Inclusion Estimators for Mendelian Randomization Studies

    PubMed Central

    Palmer, Tom M; Holmes, Michael V; Keating, Brendan J; Sheehan, Nuala A

    2017-01-01

    Abstract Mendelian randomization studies use genotypes as instrumental variables to test for and estimate the causal effects of modifiable risk factors on outcomes. Two-stage residual inclusion (TSRI) estimators have been used when researchers are willing to make parametric assumptions. However, researchers are currently reporting uncorrected or heteroscedasticity-robust standard errors for these estimates. We compared several different forms of the standard error for linear and logistic TSRI estimates in simulations and in real-data examples. Among others, we consider standard errors modified from the approach of Newey (1987), Terza (2016), and bootstrapping. In our simulations Newey, Terza, bootstrap, and corrected 2-stage least squares (in the linear case) standard errors gave the best results in terms of coverage and type I error. In the real-data examples, the Newey standard errors were 0.5% and 2% larger than the unadjusted standard errors for the linear and logistic TSRI estimators, respectively. We show that TSRI estimators with modified standard errors have correct type I error under the null. Researchers should report TSRI estimates with modified standard errors instead of reporting unadjusted or heteroscedasticity-robust standard errors. PMID:29106476

  9. Current situation of International Organization for Standardization/Technical Committee 249 international standards of traditional Chinese medicine.

    PubMed

    Liu, Yu-Qi; Wang, Yue-Xi; Shi, Nan-Nan; Han, Xue-Jie; Lu, Ai-Ping

    2017-05-01

    To review the current situation and progress of traditional Chinese medicine (TCM) international standards, standard projects and proposals in International Organization for Standardization (ISO)/ technical committee (TC) 249. ISO/TC 249 standards and standard projects on the ISO website were searched and new standard proposals information were collected from ISO/TC 249 National Mirror Committee in China. Then all the available data were summarized in 5 closely related items, including proposed time, proposed country, assigned working group (WG), current stage and classifification. In ISO/TC 249, there were 2 international standards, 18 standard projects and 24 new standard proposals proposed in 2014. These 44 standard subjects increased year by year since 2011. Twenty-nine of them were proposed by China, 15 were assigned to WG 4, 36 were in preliminary and preparatory stage and 8 were categorized into 4 fifields, 7 groups and sub-groups based on International Classifification Standards. A rapid and steady development of international standardization in TCM can be observed in ISO/TC 249.

  10. Amendments to the Center for Devices and Radiological Health federal performance standard for laser products.

    PubMed

    Dennis, J E

    1997-12-01

    Federal law requires that all laser products that are imported into or introduced into commerce in the United States comply with the performance standard published in the Code of Federal Regulations (CRF), Title 21, Parts 1040.10 and 1040.11, administered by the Center for Devices and Radiological Health (CDRH), US Food and Drug Administration. Although it contains somewhat different requirements for hazard classification, engineering controls and labeling, the ANSI Z136.1 standard defers to the CDRH standard. The CDRH standard became effective in August, 1976 and was amended, in 1978 and also in 1985. In the early 1990s, US experts met to formulate an approach to bring the requirements of the CDRH standard and those of the International Electrotechnical Commission (IEC) standard, IEC 825, into closer agreement in order to lower barriers to international trade and to remove any excessive compliance burdens on manufacturers. In 1993, the CDRH published, formally in the Federal Register and informally, a Notice of Intent to amend the CDRH standard. Responses to those notices have now been analyzed and informal draft amendments were distributed in 1996. This draft is now being prepared for formal issuance as a Notice of Proposed Rulemaking. Meanwhile, the IEC standard was amended in 1993 and republished as IEC 825-1; these amendments created considerable controversy since they resulted in over classification of the hazard of many products, especially light emitting diodes (LEDs) that have a large divergence and increased source dimensions. Additional amendments are now being developed to correct this problem. The CDRH has carefully monitored developments in the IEC and actively participated in its proceedings as a guide in developing its own proposal. This paper describes the major changes that are being proposed for the CDRH standard and presents some rationale for the major changes. The more significant changes include expansion of applicability to include LEDs, reduced emission durations for classification, revised measurement for hazard classification, reduced performance requirements for lower power visible radiation products, and revised requirements for medical products.

  11. A Strategy to Increase the International Visibility and Participation of a State University

    ERIC Educational Resources Information Center

    Lucas, Stephen R.; Miles, Benton E.

    2007-01-01

    This paper presents a strategy for expanding a university's international participation. An effort to correct international exchange imbalances evolved into a unique international program and partnership with Walt Disney World.

  12. Dynamic 2D self-phase-map Nyquist ghost correction for simultaneous multi-slice echo planar imaging.

    PubMed

    Yarach, Uten; Tung, Yi-Hang; Setsompop, Kawin; In, Myung-Ho; Chatnuntawech, Itthi; Yakupov, Renat; Godenschweger, Frank; Speck, Oliver

    2018-02-09

    To develop a reconstruction pipeline that intrinsically accounts for both simultaneous multislice echo planar imaging (SMS-EPI) reconstruction and dynamic slice-specific Nyquist ghosting correction in time-series data. After 1D slice-group average phase correction, the separate polarity (i.e., even and odd echoes) SMS-EPI data were unaliased by slice GeneRalized Autocalibrating Partial Parallel Acquisition. Both the slice-unaliased even and odd echoes were jointly reconstructed using a model-based framework, extended for SMS-EPI reconstruction that estimates a 2D self-phase map, corrects dynamic slice-specific phase errors, and combines data from all coils and echoes to obtain the final images. The percentage ghost-to-signal ratios (%GSRs) and its temporal variations for MB3R y 2 with a field of view/4 shift in a human brain obtained by the proposed dynamic 2D and standard 1D phase corrections were 1.37 ± 0.11 and 2.66 ± 0.16, respectively. Even with a large regularization parameter λ applied in the proposed reconstruction, the smoothing effect in fMRI activation maps was comparable to a very small Gaussian kernel size 1 × 1 × 1 mm 3 . The proposed reconstruction pipeline reduced slice-specific phase errors in SMS-EPI, resulting in reduction of GSR. It is applicable for functional MRI studies because the smoothing effect caused by the regularization parameter selection can be minimal in a blood-oxygen-level-dependent activation map. © 2018 International Society for Magnetic Resonance in Medicine.

  13. Oxygen permeability of the pigmented material used in cosmetic daily disposable contact lenses

    PubMed Central

    Galas, Stephen; Copper, Lenora L

    2016-01-01

    Purpose To evaluate the individual contributions of pigment colorant and packing solution containing polyvinyl pyrrolidone (PVP) on the oxygen permeability (Dk) of a cosmetic printed etafilcon A daily disposable contact lens packaged with PVP. Method The oxygen transport of a contact lens is evaluated through the central optical zone of the lens. Cosmetic printed contact lenses contain pigment colorant in the periphery or mid-periphery of the lens. Therefore, to assess the impact of cosmetic print on oxygen permeability, special lenses need to be produced that contain the colorant within the central optical zone. This technique was used to obtain multiple measurements of nonedge-corrected Dk/t of both the center pigmented lens and its nonpigmented equivalent, using a polarographic measurement described in International Organization for Standardization (ISO) 18369-4:2006(E), and the Dk derived for each measurement is corrected for edge effect. In addition, the edge-corrected Dk values of lenses made from the same monomer batch were measured. The lenses were packaged and autoclaved with and without proprietary technology which embeds PVP in the contact lens during autoclaving. The resulting Dk value of the printed lens material was then used with thickness data to generate true Dk/t profiles for a given lens power. Results The edge-corrected Dk of the printed etafilcon A lens with offset pigment colorant was measured to be 19.7×10−11 (cm2/s) (mL O2/mL·mmHg) at 35°C. This was within ±20% tolerance range as specified in ISO 18369-2:2012(E) for the edge-corrected Dk of the nonpigmented etafilcon A control lens evaluated during the same session, 19.5×10−11 (cm2/s) (mL O2/mL·mmHg). The edge-corrected Dk values of the lenses packaged with PVP (mean 20.1, standard deviation [SD] 0.3) were also within the ±20% tolerance range compared to those packaged without PVP (mean 20.0, SD 0.3). Conclusion The pigment colorant and PVP embedded in the contact lens during autoclaving were not found to influence the oxygen permeability of the etafilcon A material. PMID:28003735

  14. Corrections Officer Physical Abilities Report. Standards and Training for Corrections Program.

    ERIC Educational Resources Information Center

    California State Board of Corrections, Sacramento.

    A study examined the physical ability requirements for entry-level corrections officers in the California. The study, which was undertaken at the request of the California Board of Corrections, had the following objectives: statewide job analysis of the requirements of three entry-level positions in county agencies--corrections officer, probation…

  15. 28 CFR 115.188 - Data review for corrective action.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Data review for corrective action. 115.188 Section 115.188 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PRISON RAPE ELIMINATION ACT NATIONAL STANDARDS Standards for Lockups Data Collection and Review § 115.188 Data review for...

  16. 28 CFR 115.188 - Data review for corrective action.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Data review for corrective action. 115.188 Section 115.188 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PRISON RAPE ELIMINATION ACT NATIONAL STANDARDS Standards for Lockups Data Collection and Review § 115.188 Data review for...

  17. 28 CFR 115.188 - Data review for corrective action.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Data review for corrective action. 115.188 Section 115.188 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PRISON RAPE ELIMINATION ACT NATIONAL STANDARDS Standards for Lockups Data Collection and Review § 115.188 Data review for...

  18. 7 CFR 75.25 - Issuance of corrected certificate.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Issuance of corrected certificate. 75.25 Section 75.25 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT...

  19. 7 CFR 75.25 - Issuance of corrected certificate.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Issuance of corrected certificate. 75.25 Section 75.25 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT...

  20. 7 CFR 75.25 - Issuance of corrected certificate.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Issuance of corrected certificate. 75.25 Section 75.25 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT...

  1. 7 CFR 75.25 - Issuance of corrected certificate.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Issuance of corrected certificate. 75.25 Section 75.25 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT...

  2. 7 CFR 75.25 - Issuance of corrected certificate.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Issuance of corrected certificate. 75.25 Section 75.25 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT...

  3. 75 FR 61143 - Financial Management and Assurance; Government Auditing Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-04

    ... GOVERNMENT ACCOUNTABILITY OFFICE Financial Management and Assurance; Government Auditing Standards Correction In notice document 2010-23374 beginning on page 57274 in the issue of Monday, September 20, 2010 make the following corrections: 1. On page 57275, in the first column, under the ADDRESSES section, in...

  4. Hypothesis Testing Using Factor Score Regression

    PubMed Central

    Devlieger, Ines; Mayer, Axel; Rosseel, Yves

    2015-01-01

    In this article, an overview is given of four methods to perform factor score regression (FSR), namely regression FSR, Bartlett FSR, the bias avoiding method of Skrondal and Laake, and the bias correcting method of Croon. The bias correcting method is extended to include a reliable standard error. The four methods are compared with each other and with structural equation modeling (SEM) by using analytic calculations and two Monte Carlo simulation studies to examine their finite sample characteristics. Several performance criteria are used, such as the bias using the unstandardized and standardized parameterization, efficiency, mean square error, standard error bias, type I error rate, and power. The results show that the bias correcting method, with the newly developed standard error, is the only suitable alternative for SEM. While it has a higher standard error bias than SEM, it has a comparable bias, efficiency, mean square error, power, and type I error rate. PMID:29795886

  5. Surgical correction of severe spinal deformities using a staged protocol of external and internal techniques.

    PubMed

    Prudnikova, Oksana G; Shchurova, Elena N

    2018-02-01

    There is high risk of neurologic complications in one-stage management of severe rigid spinal deformities in adolescents. Therefore, gradual spine stretching variants are applied. One of them is the use of external transpedicular fixation. Our aim was to retrospectively study the outcomes of gradual correction with an apparatus for external transpedicular fixation followed by internal fixation used for high-grade kyphoscoliosis in adolescents. Twenty five patients were reviewed (mean age, 15.1 ± 0.4 years). Correction was performed in two stages: 1) gradual controlled correction with the apparatus for external transpedicular fixation; and 2) internal posterior transpedicular fixation. Rigid deformities in eight patients required discapophysectomy. Clinical and radiographic study of the outcomes was conducted immediately after treatment and at a mean long-term period of 3.8 ± 0.4 years. Pain was evaluated using the visual analogue scale (VAS, 10 points). The Oswestry questionnaire (ODI scale) was used for functional assessment. Deformity correction with the external apparatus was 64.2 ± 4.6% in the main curve and 60.7 ± 3.7% in the compensatory one. It was 72.8 ± 4.1% and 66.2 ± 5.3% immediately after treatment and 70.8 ± 4.6% and 64.3 ± 4.2% at long term, respectively. Pain relieved by 33.2 ± 4.2% (p < 0.05) immediately after treatment and by 55.6 ± 2.8% (p < 0.05) at long term. ODI reduced by 30.2 ± 1.7% (p < 0.05) immediately after treatment and by 37.2 ± 1.6% (p < 0.05) at long term. The apparatus for external transpedicular fixation provides gradual controlled correction for high-grade kyphoscoliosis in adolescents. Transition to internal fixation preserves the correction achieved, and correction is maintained at long term.

  6. Bilateral comparison on electric field measurements between TÜBİTAK UME and SASO NMCC

    NASA Astrophysics Data System (ADS)

    Aslan, Çağlar; Alrobaish, Abdullah M.; Şen, Osman

    2017-01-01

    Electromagnetic (EM) probes are widely utilized in the measurement of EM fields for non-ionizing radiation, electromagnetic compatibility (EMC) testing and other applications in the frequency range 5 Hz-60 GHz. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as IEEE 1309. The existing NMIs or emerging NMIs should refer to the international comparison measurements in order to assure the quality of their measurement results. Therefore, the electric field comparison measurements organized by TUBITAK UME were performed between TUBITAK UME and SASO NMCC at the 100 Hz, 1 kHz, 10 MHz, 100 MHz, 1 GHz, 10 GHz and 18 GHz frequencies in order to obtain the correction factors of the electric field probes. The comparison measurements were carried out in accordance with the Technical Protocol prepared by TUBITAK UME. The measurements started in October 2017 and were completed in January 2017. There was good agreement found for the correction factors. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Duty Hour Compliance: A Survey of U.S. Military Medical Interns and Residents.

    PubMed

    Blitz, Jason B; Rogers, Amy E; Polmear, Michael M; Owings, Alfred J

    2017-11-01

    In 2011, the Accreditation Council for Graduate Medical Education (ACGME) modified its duty hour standards for interns and residents. This was done, in part, because of a belief that increased compliance with these standards was needed to positively impact resident fatigue, resident quality of life, and patient safety. However, several studies indicate that duty hour noncompliance and false reporting by interns and residents remains a significant concern for residency program directors. This study examined the compliance of interns and residents with ACGME duty hour standards at a large military graduate medical education (GME) training program. We conducted a survey of 535 trainees assigned to 24 GME programs within the National Capital Consortium (NCC). Statistical analysis for descriptive parameters used a standard error of measure on the basis of sample and target population sizes to calculate two-sided 95% confidence intervals (CIs). A χ 2 analysis was performed to compare response differences for particular survey questions. A Cronbach α coefficient was calculated to compare the internal consistency of responses for questions in which individual responses were expected to correlate. This study was reviewed by the Offices of Research at the Walter Reed National Military Medical Center and the Uniformed Services University and adjudicated as "Not Research." Overall, 41.3% (N = 221) of those contacted completed all survey questions. From the available responses, 31.6% (95% CI, 26.9-36.2) reported at least one occurrence of implicit pressure to alter duty hour reporting, and 32.0% (95% CI, 27.3-36.7) reported at least one occurrence of altering reported duty hours. In addition, 37.2 (95% CI, 32.5-41.9) reported being unable to always follow duty hour limits and 58.1% (95% CI, 53.1-63.1) felt time working at home on residency requirements should be included in reported duty hours. Our results indicate that a significant portion of interns and residents within the NCC were unable to consistently follow ACGME duty hour standards and various systemic barriers within the GME training environment may have contributed. To remove or mitigate these barriers, we recommend using an approach similar to those of "high-reliability organizations" in which organizational processes are systematically investigated to improve safety, quality, and efficiency. Additional surveys or cognitive interviewing within the NCC and at other military GME training sites could be used to help refine these barriers, discover other barriers, determine the scope of these issues within the entire military GME training system, and to measure the outcome of correction actions. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  8. The effects of deterioration and technological levels on pollutant emission factors for gasoline light-duty trucks.

    PubMed

    Zhang, Qingyu; Fan, Juwang; Yang, Weidong; Chen, Bixin; Zhang, Lijuan; Liu, Jiaoyu; Wang, Jingling; Zhou, Chunyao; Chen, Xuan

    2017-07-01

    Vehicle deterioration and technological change influence emission factors (EFs). In this study, the impacts of vehicle deterioration and emission standards on EFs of regulated pollutants (carbon monoxide [CO], hydrocarbon [HC], and nitrogen oxides [NO x ]) for gasoline light-duty trucks (LDTs) were investigated according to the inspection and maintenance (I/M) data using a chassis dynamometer method. Pollutant EFs for LDTs markedly varied with accumulated mileages and emission standards, and the trends of EFs are associated with accumulated mileages. In addition, the study also found that in most cases, the median EFs of CO, HC, and NO x are higher than those of basic EFs in the International Vehicle Emissions (IVE) model; therefore, the present study provides correction factors for the IVE model relative to the corresponding emission standards and mileages. Currently, vehicle emissions are great contributors to air pollution in cities, especially in developing countries. Emission factors play a key role in creating emission inventory and estimating emissions. Deterioration represented by vehicle age and accumulated mileage and changes of emission standards markedly influence emission factors. In addition, the results provide collection factors for implication in the IVE model in the region levels.

  9. A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA

    NASA Astrophysics Data System (ADS)

    Pavlis, Nikolaos K.; Weiss, Marc A.

    2017-08-01

    We re-evaluated the relativistic redshift correction applicable to the frequency standards at the National Institute of Standards and Technology (NIST) in Boulder, Colorado, USA, based on a precise GPS survey of three benchmarks on the roof of the building where these standards had been previously housed, and on global and regional geoid models supported by data from the GRACE and GOCE missions, including EGM2008, USGG2009, and USGG2012. We also evaluated the redshift offset based on the published NAVD88 geopotential number of the leveling benchmark Q407 located on the side of Building 1 at NIST, Boulder, Colorado, USA, after estimating the bias of the NAVD88 datum at our specific location. Based on these results, our current best estimate of the relativistic redshift correction, if frequency standards were located at the height of the leveling benchmark Q407 outside the second floor of Building 1, with respect to the EGM2008 geoid whose potential has been estimated to be {{W}0}=62 636 855.69 {{m}2} {{s}-2} , is equal to (-1798.50  ±  0.06)  ×  10-16. The corresponding value, with respect to an equipotential surface defined by the International Astronomical Union’s (IAU) adopted value of {{W}0}=62 636 856.0 {{m}2} {{s}-2} , is (-1798.53  ±  0.06)  ×  10-16. These values are comparable to the value of (-1798.70  ±  0.30)  ×  10-16, estimated by Pavlis and Weiss in 2003, with respect to an equipotential surface defined by {{W}0}=62 636 856.88 {{m}2} {{s}-2} . The minus sign implies that clocks run faster in the laboratory in Boulder than a corresponding clock located on the geoid. Contribution of US government, not subject to Copyright.

  10. Comprehensive Auditing in Nuclear Medicine Through the International Atomic Energy Agency Quality Management Audits in Nuclear Medicine (QUANUM) Program. Part 1: the QUANUM Program and Methodology.

    PubMed

    Dondi, Maurizio; Torres, Leonel; Marengo, Mario; Massardo, Teresa; Mishani, Eyal; Van Zyl Ellmann, Annare; Solanki, Kishor; Bischof Delaloye, Angelika; Lobato, Enrique Estrada; Miller, Rodolfo Nunez; Paez, Diana; Pascual, Thomas

    2017-11-01

    An effective management system that integrates quality management is essential for a modern nuclear medicine practice. The Nuclear Medicine and Diagnostic Imaging Section of the International Atomic Energy Agency (IAEA) has the mission of supporting nuclear medicine practice in low- and middle-income countries and of helping them introduce it in their health-care system, when not yet present. The experience gathered over several years has shown diversified levels of development and varying degrees of quality of practice, among others because of limited professional networking and limited or no opportunities for exchange of experiences. Those findings triggered the development of a program named Quality Management Audits in Nuclear Medicine (QUANUM), aimed at improving the standards of NM practice in low- and middle-income countries to internationally accepted standards through the introduction of a culture of quality management and systematic auditing programs. QUANUM takes into account the diversity of nuclear medicine services around the world and multidisciplinary contributions to the practice. Those contributions include clinical, technical, radiopharmaceutical, and medical physics procedures. Aspects of radiation safety and patient protection are also integral to the process. Such an approach ensures consistency in providing safe services of superior quality to patients. The level of conformance is assessed using standards based on publications of the IAEA and the International Commission on Radiological Protection, and guidelines from scientific societies such as Society of Nuclear Medicine and Molecular Imaging (SNMMI) and European Association of Nuclear Medicine (EANM). Following QUANUM guidelines and by means of a specific assessment tool developed by the IAEA, auditors, both internal and external, will be able to evaluate the level of conformance. Nonconformances will then be prioritized and recommendations will be provided during an exit briefing. The same tool could then be applied to assess any improvement after corrective actions are taken. This is the first comprehensive audit program in nuclear medicine that helps evaluate managerial aspects, safety of patients and workers, clinical practice, and radiopharmacy, and, above all, keeps them under control all together, with the intention of continuous improvement. Copyright © 2017. Published by Elsevier Inc.

  11. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Improved δ(13)C analysis of amino sugars in soil by ion chromatography-oxidation-isotope ratio mass spectrometry.

    PubMed

    Dippold, Michaela A; Boesel, Stefanie; Gunina, Anna; Kuzyakov, Yakov; Glaser, Bruno

    2014-03-30

    Amino sugars build up microbial cell walls and are important components of soil organic matter. To evaluate their sources and turnover, δ(13)C analysis of soil-derived amino sugars by liquid chromatography was recently suggested. However, amino sugar δ(13)C determination remains challenging due to (1) a strong matrix effect, (2) CO2 -binding by alkaline eluents, and (3) strongly different chromatographic behavior and concentrations of basic and acidic amino sugars. To overcome these difficulties we established an ion chromatography-oxidation-isotope ratio mass spectrometry method to improve and facilitate soil amino sugar analysis. After acid hydrolysis of soil samples, the extract was purified from salts and other components impeding chromatographic resolution. The amino sugar concentrations and δ(13)C values were determined by coupling an ion chromatograph to an isotope ratio mass spectrometer. The accuracy and precision of quantification and δ(13)C determination were assessed. Internal standards enabled correction for losses during analysis, with a relative standard deviation <6%. The higher magnitude peaks of basic than of acidic amino sugars required an amount-dependent correction of δ(13)C values. This correction improved the accuracy of the determination of δ(13)C values to <1.5‰ and the precision to <0.5‰ for basic and acidic amino sugars in a single run. This method enables parallel quantification and δ(13)C determination of basic and acidic amino sugars in a single chromatogram due to the advantages of coupling an ion chromatograph to the isotope ratio mass spectrometer. Small adjustments of sample amount and injection volume are necessary to optimize precision and accuracy for individual soils. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Performance evaluation of the whole-body PET scanner ECAT EXACT HR/sup +/ following the IEC standard

    NASA Astrophysics Data System (ADS)

    Adam, L.-E.; Zaers, J.; Ostertag, H.; Trojan, H.; Bellemann, M. E.; Brix, G.

    1997-06-01

    The performance parameters of the whole-body PET scanner ECAT EXACT HR/sup +/ (CTI/Siemens, Knoxville, TN) were determined following the standard proposed by the International Electrotechnical Commission (IEC). The tests were expanded by some measurements concerning the accuracy of the correction algorithms and the geometric fidelity of the reconstructed images. The scanner consists of 32 rings, each with 576 BGO detectors (4.05/spl times/4.39/spl times/30 mm/sup 3/), covering an axial field-of-view of 15.5 cm and a patient port of 56.2 cm. The transaxial FWHM determined by a Gaussian fit in the 2D (3D) mode is 4.5 (4.3) mm at the center. It increases to 8.9 (8.3) mm radially and to 5.8 (5.2) mm tangentially at a radial distance of r=20 cm. The average axial resolution varies between 4.9 (4.1) mm FWHM at the center and 8.8 (8.1) mm at r=20 cm. The system sensitivity for unscattered true events is 5.85 (26.4) cps/Bq/ml (measured with a 20 cm cylinder). The 50% dead-time losses were reached for a true event count rate (including scatter) of 286 (500) kcps at an activity concentration of 74 (25) kBq/ml. The system scatter fraction is 0.24 (0.35). With the exception of the 3D attenuation correction algorithm, all correction algorithms work reliably. The results reveal that the ECAT EXACT HR/sup +/ has a good and nearly isotropic spatial resolution. Due to the small detector elements, however, it has a low slice sensitivity which is a limiting factor for image quality.

  14. High-precision measurement of (186)Os/(188)Os and (187)Os/(188)Os: isobaric oxide corrections with in-run measured oxygen isotope ratios.

    PubMed

    Chu, Zhu-Yin; Li, Chao-Feng; Chen, Zhi; Xu, Jun-Jie; Di, Yan-Kun; Guo, Jing-Hui

    2015-09-01

    We present a novel method for high precision measurement of (186)Os/(188)Os and (187)Os/(188)Os ratios, applying isobaric oxide interference correction based on in-run measurements of oxygen isotopic ratios. For this purpose, we set up a static data collection routine to measure the main Os(16)O3(-) ion beams with Faraday cups connected to conventional 10(11) amplifiers, and (192)Os(16)O2(17)O(-) and (192)Os(16)O2(18)O(-) ion beams with Faraday cups connected to 10(12) amplifiers. Because of the limited number of Faraday cups, we did not measure (184)Os(16)O3(-) and (189)Os(16)O3(-) simultaneously in-run, but the analytical setup had no significant influence on final (186)Os/(188)Os and (187)Os/(188)Os data. By analyzing UMd, DROsS, an in-house Os solution standard, and several rock reference materials, including WPR-1, WMS-1a, and Gpt-5, the in-run measured oxygen isotopic ratios were proven to present accurate Os isotopic data. However, (186)Os/(188)Os and (187)Os/(188)Os data obtained with in-run O isotopic compositions for the solution standards and rock reference materials show minimal improvement in internal and external precision, compared to the conventional oxygen correction method. We concluded that, the small variations of oxygen isotopes during OsO3(-) analytical sessions are probably not the main source of error for high precision Os isotopic analysis. Nevertheless, use of run-specific O isotopic compositions is still a better choice for Os isotopic data reduction and eliminates the requirement of extra measurements of the oxygen isotopic ratios.

  15. A Hertzian contact mechanics based formulation to improve ultrasound elastography assessment of uterine cervical tissue stiffness.

    PubMed

    Briggs, Brandi N; Stender, Michael E; Muljadi, Patrick M; Donnelly, Meghan A; Winn, Virginia D; Ferguson, Virginia L

    2015-06-25

    Clinical practice requires improved techniques to assess human cervical tissue properties, especially at the internal os, or orifice, of the uterine cervix. Ultrasound elastography (UE) holds promise for non-invasively monitoring cervical stiffness throughout pregnancy. However, this technique provides qualitative strain images that cannot be linked to a material property (e.g., Young's modulus) without knowledge of the contact pressure under a rounded transvaginal transducer probe and correction for the resulting non-uniform strain dissipation. One technique to standardize elastogram images incorporates a material of known properties and uses one-dimensional, uniaxial Hooke's law to calculate Young's modulus within the compressed material half-space. However, this method does not account for strain dissipation and the strains that evolve in three-dimensional space. We demonstrate that an analytical approach based on 3D Hertzian contact mechanics provides a reasonable first approximation to correct for UE strain dissipation underneath a round transvaginal transducer probe and thus improves UE-derived estimates of tissue modulus. We validate the proposed analytical solution and evaluate sources of error using a finite element model. As compared to 1D uniaxial Hooke's law, the Hertzian contact-based solution yields significantly improved Young's modulus predictions in three homogeneous gelatin tissue phantoms possessing different moduli. We also demonstrate the feasibility of using this technique to image human cervical tissue, where UE-derived moduli estimations for the uterine cervix anterior lip agreed well with published, experimentally obtained values. Overall, UE with an attached reference standard and a Hertzian contact-based correction holds promise for improving quantitative estimates of cervical tissue modulus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. 78 FR 59228 - Requirement of a Section 4959 Excise Tax Return and Time for Filing the Return; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... the community health needs assessment (CHNA) requirements for any taxable year. DATES: This correction... the reporting of the excise tax under section 4959 of the Internal Revenue Code. Need for Correction... misleading and are in need of clarification. Correction of Publication Accordingly, the final and temporary...

  17. 42 CFR 493.1282 - Standard: Corrective actions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Corrective actions. 493.1282 Section 493.1282 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... values that are outside of the laboratory's reportable range of test results for the test system; and...

  18. 75 FR 39052 - 2010 Standards for Delineating Metropolitan and Micropolitan Statistical Areas

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-07

    ... OFFICE OF MANAGEMENT AND BUDGET 2010 Standards for Delineating Metropolitan and Micropolitan Statistical Areas Correction In notice document 2010-15605 beginning on page 37246 in the issue of Monday, June 28, 2010, make the following corrections: 1. On page 37250, in the second column, under Section 7...

  19. Deviation Management: Key Management Subsystem Driver of Knowledge-Based Continuous Improvement in the Henry Ford Production System.

    PubMed

    Zarbo, Richard J; Copeland, Jacqueline R; Varney, Ruan C

    2017-10-01

    To develop a business subsystem fulfilling International Organization for Standardization 15189 nonconformance management regulatory standard, facilitating employee engagement in problem identification and resolution to effect quality improvement and risk mitigation. From 2012 to 2016, the integrated laboratories of the Henry Ford Health System used a quality technical team to develop and improve a management subsystem designed to identify, track, trend, and summarize nonconformances based on frequency, risk, and root cause for elimination at the level of the work. Programmatic improvements and training resulted in markedly increased documentation culminating in 71,641 deviations in 2016 classified by a taxonomy of 281 defect types into preanalytic (74.8%), analytic (23.6%), and postanalytic (1.6%) testing phases. The top 10 deviations accounted for 55,843 (78%) of the total. Deviation management is a key subsystem of managers' standard work whereby knowledge of nonconformities assists in directing corrective actions and continuous improvements that promote consistent execution and higher levels of performance. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  20. An investigation of the matrix sensitivity of refinery gas analysis using gas chromatography with flame ionisation detection.

    PubMed

    Ferracci, Valerio; Brown, Andrew S; Harris, Peter M; Brown, Richard J C

    2015-02-27

    The response of a flame ionisation detector (FID) on a gas chromatograph to methane, ethane, propane, i-butane and n-butane in a series of multi-component refinery gas standards was investigated to assess the matrix sensitivity of the instrument. High-accuracy synthetic gas standards, traceable to the International System of Units, were used to minimise uncertainties. The instrument response exhibited a small dependence on the component amount fraction: this behaviour, consistent with that of another FID, was thoroughly characterised over a wide range of component amount fractions and was shown to introduce a negligible bias in the analysis of refinery gas samples, provided a suitable reference standard is employed. No significant effects of the molar volume, density and viscosity of the gas mixtures on the instrument response were observed, indicating that the FID is suitable for the analysis of refinery gas mixtures over a wide range of component amount fractions provided that appropriate drift-correction procedures are employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. The SEASAT altimeter wet tropospheric range correction revisited

    NASA Technical Reports Server (NTRS)

    Tapley, D. B.; Lundberg, J. B.; Born, G. H.

    1984-01-01

    An expanded set of radiosonde observations was used to calculate the wet tropospheric range correction for the brightness temperature measurements of the SEASAT scanning multichannel microwave radiometer (SMMR). The accuracy of the conventional algorithm for wet tropospheric range correction was evaluated. On the basis of the expanded observational data set, the algorithm was found to have a bias of about 1.0 cm, and a standard deviation 2.8 cm. In order to improve the algorithm, the exact linear, quadratic and logarithmic relationships between brightness temperatures and range corrections were determined. Various combinations of measurement parameters were used to reduce the standard deviation between SEASAT SMMR and radiosonde observations to about 2.1 cm. The performance of various range correction formulas is compared in a table.

  2. Extended Glauert tip correction to include vortex rollup effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maniaci, David; Schmitz, Sven

    Wind turbine loads predictions by blade-element momentum theory using the standard tip-loss correction have been shown to over-predict loading near the blade tip in comparison to experimental data. This over-prediction is theorized to be due to the assumption of light rotor loading, inherent in the standard tip-loss correction model of Glauert. A higher- order free-wake method, WindDVE, is used to compute the rollup process of the trailing vortex sheets downstream of wind turbine blades. Results obtained serve an exact correction function to the Glauert tip correction used in blade-element momentum methods. Lastly, it is found that accounting for the effectsmore » of tip vortex rollup within the Glauert tip correction indeed results in improved prediction of blade tip loads computed by blade-element momentum methods.« less

  3. Extended Glauert tip correction to include vortex rollup effects

    DOE PAGES

    Maniaci, David; Schmitz, Sven

    2016-10-03

    Wind turbine loads predictions by blade-element momentum theory using the standard tip-loss correction have been shown to over-predict loading near the blade tip in comparison to experimental data. This over-prediction is theorized to be due to the assumption of light rotor loading, inherent in the standard tip-loss correction model of Glauert. A higher- order free-wake method, WindDVE, is used to compute the rollup process of the trailing vortex sheets downstream of wind turbine blades. Results obtained serve an exact correction function to the Glauert tip correction used in blade-element momentum methods. Lastly, it is found that accounting for the effectsmore » of tip vortex rollup within the Glauert tip correction indeed results in improved prediction of blade tip loads computed by blade-element momentum methods.« less

  4. A Novel Vaping Machine Dedicated to Fully Controlling the Generation of E-Cigarette Emissions

    PubMed Central

    Soulet, Sébastien; Pairaud, Charly; Lalo, Hélène

    2017-01-01

    The accurate study of aerosol composition and nicotine release by electronic cigarettes is a major issue. In order to fully and correctly characterize aerosol, emission generation has to be completely mastered. This study describes an original vaping machine named Universal System for Analysis of Vaping (U-SAV), dedicated to vaping product study, enabling the control and real-time monitoring of applied flow rate and power. Repeatability and stability of the machine are demonstrated on flow rate, power regulation and e-liquid consumption. The emission protocol used to characterize the vaping machine is based on the AFNOR-XP-D90-300-3 standard (15 W power, 1 Ω atomizer resistance, 100 puffs collected per session, 1.1 L/min airflow rate). Each of the parameters has been verified with two standardized liquids by studying mass variations, power regulation and flow rate stability. U-SAV presents the required and necessary stability for the full control of emission generation. The U-SAV is recognised by the French association for standardization (AFNOR), European Committee for Standardization (CEN) and International Standards Organisation (ISO) as a vaping machine. It can be used to highlight the influence of the e-liquid composition, user behaviour and nature of the device, on the e-liquid consumption and aerosol composition. PMID:29036888

  5. A Novel Vaping Machine Dedicated to Fully Controlling the Generation of E-Cigarette Emissions.

    PubMed

    Soulet, Sébastien; Pairaud, Charly; Lalo, Hélène

    2017-10-14

    The accurate study of aerosol composition and nicotine release by electronic cigarettes is a major issue. In order to fully and correctly characterize aerosol, emission generation has to be completely mastered. This study describes an original vaping machine named Universal System for Analysis of Vaping (U-SAV), dedicated to vaping product study, enabling the control and real-time monitoring of applied flow rate and power. Repeatability and stability of the machine are demonstrated on flow rate, power regulation and e-liquid consumption. The emission protocol used to characterize the vaping machine is based on the AFNOR-XP-D90-300-3 standard (15 W power, 1 Ω atomizer resistance, 100 puffs collected per session, 1.1 L/min airflow rate). Each of the parameters has been verified with two standardized liquids by studying mass variations, power regulation and flow rate stability. U-SAV presents the required and necessary stability for the full control of emission generation. The U-SAV is recognised by the French association for standardization (AFNOR), European Committee for Standardization (CEN) and International Standards Organisation (ISO) as a vaping machine. It can be used to highlight the influence of the e-liquid composition, user behaviour and nature of the device, on the e-liquid consumption and aerosol composition.

  6. An internationally standardized species identification test for use on suspected seized rhinoceros horn in the illegal wildlife trade.

    PubMed

    Ewart, Kyle M; Frankham, Greta J; McEwing, Ross; Webster, Lucy M I; Ciavaglia, Sherryn A; Linacre, Adrian M T; The, Dang Tat; Ovouthan, Kanitia; Johnson, Rebecca N

    2018-01-01

    Rhinoceros (rhino) numbers have dwindled substantially over the past century. As a result, three of the five species are now considered to be critically endangered, one species is vulnerable and one species is near-threatened. Poaching has increased dramatically over the past decade due to a growing demand for rhino horn products, primarily in Asia. Improved wildlife forensic techniques, such as validated tests for species identification of seized horns, are critical to aid current enforcement and prosecution efforts and provide a deterrent to future rhino horn trafficking. Here, we present an internationally standardized species identification test based on a 230 base pair cytochrome-b region. This test improves on previous nested PCR protocols and can be used for the discrimination of samples with <20pg of template DNA, thus suitable for DNA extracted from horn products. The assay was designed to amplify water buffalo samples, a common 'rhino horn' substitute, but to exclude human DNA, a common contaminant. Phylogenetic analyses using this partial cytochrome-b region resolved the five extant rhino species. Testing successfully returned a sequence and correct identification for all of the known rhino horn samples and vouchered rhino samples from museum and zoo collections, and provided species level identification for 47 out of 52 unknown samples from seizures. Validation and standardization was carried out across five different laboratories, in four different countries, demonstrating it to be an effective and reproducible test, robust to inter laboratory variation in equipment and consumables (such as PCR reagents). This is one of the first species identification tests to be internationally standardized to produce data for evidential proceedings and the first published validated test for rhinos, one of the flagship species groups of the illegal wildlife trade and for which forensic tools are urgently required. This study serves as a model for how species identification tests should be standardized and disseminated for wildlife forensic testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Determination of diethanolamine or N-methyldiethanolamine in high ammonium concentration matrices by capillary electrophoresis with indirect UV detection: application to the analysis of refinery process waters.

    PubMed

    Bord, N; Crétier, G; Rocca, J-L; Bailly, C; Souchez, J-P

    2004-09-01

    Alkanolamines such as diethanolamine (DEA) and N-methyldiethanolamine (MDEA) are used in desulfurization processes in crude oil refineries. These compounds may be found in process waters following an accidental contamination. The analysis of alkanolamines in refinery process waters is very difficult due to the high ammonium concentration of the samples. This paper describes a method for the determination of DEA in high ammonium concentration refinery process waters by using capillary electrophoresis (CE) with indirect UV detection. The same method can be used for the determination of MDEA. Best results were achieved with a background electrolyte (BGE) comprising 10 mM histidine adjusted to pH 5.0 with acetic acid. The development of this electrolyte and the analytical performances are discussed. The quantification was performed by using internal standardization, by which triethanolamine (TEA) was used as internal standard. A matrix effect due to the high ammonium content has been highlighted and standard addition was therefore used. The developed method was characterized in terms of repeatability of migration times and corrected peak areas, linearity, and accuracy. Limits of detection (LODs) and quantification (LOQs) obtained were 0.2 and 0.7 ppm, respectively. The CE method was applied to the determination of DEA or MDEA in refinery process waters spiked with known amounts of analytes and it gave excellent results, since uncertainties obtained were 8 and 5%, respectively.

  8. Improved protein hydrogen/deuterium exchange mass spectrometry platform with fully automated data processing.

    PubMed

    Zhang, Zhongqi; Zhang, Aming; Xiao, Gang

    2012-06-05

    Protein hydrogen/deuterium exchange (HDX) followed by protease digestion and mass spectrometric (MS) analysis is accepted as a standard method for studying protein conformation and conformational dynamics. In this article, an improved HDX MS platform with fully automated data processing is described. The platform significantly reduces systematic and random errors in the measurement by introducing two types of corrections in HDX data analysis. First, a mixture of short peptides with fast HDX rates is introduced as internal standards to adjust the variations in the extent of back exchange from run to run. Second, a designed unique peptide (PPPI) with slow intrinsic HDX rate is employed as another internal standard to reflect the possible differences in protein intrinsic HDX rates when protein conformations at different solution conditions are compared. HDX data processing is achieved with a comprehensive HDX model to simulate the deuterium labeling and back exchange process. The HDX model is implemented into the in-house developed software MassAnalyzer and enables fully unattended analysis of the entire protein HDX MS data set starting from ion detection and peptide identification to final processed HDX output, typically within 1 day. The final output of the automated data processing is a set (or the average) of the most possible protection factors for each backbone amide hydrogen. The utility of the HDX MS platform is demonstrated by exploring the conformational transition of a monoclonal antibody by increasing concentrations of guanidine.

  9. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, Aron M; Wilbert, Stefan; Jessen, Wilko

    This paper introduces a concept for global tilted irradiance (GTI) subordinate standard spectra to supplement the current standard spectra used in solar photovoltaic applications as defined in ASTM G173 and IEC60904. The proposed subordinate standard spectra correspond to atmospheric conditions and tilt angles that depart significantly from the main standard spectrum, and they can be used to more accurately represent various local conditions. For the definition of subordinate standard spectra cases with an elevation 1.5 km above sea level, the question arises whether the air mass should be calculated including a pressure correction or not. This study focuses on themore » impact of air mass used in standard spectra, and it uses data from 29 locations to examine which air mass is most appropriate for GTI and direct normal irradiance (DNI) spectra. Overall, it is found that the pressure-corrected air mass of 1.5 is most appropriate for DNI spectra. For GTI, a non-pressure-corrected air mass of 1.5 was found to be more appropriate.« less

  10. Manners of Speaking: Linguistic Capital and the Rhetoric of Correctness in Late-Nineteenth-Century America

    ERIC Educational Resources Information Center

    Herring, William Rodney, Jr.

    2009-01-01

    A number of arguments appeared in the late-nineteenth-century United States about "correctness" in language, arguments for and against enforcing a standard of correctness and arguments about what should count as correct in language. Insofar as knowledge about and facility with "correct" linguistic usage could affect one's standing in the social…

  11. 28 CFR 115.404 - Audit corrective action plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Audit corrective action plan. 115.404 Section 115.404 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PRISON RAPE ELIMINATION ACT NATIONAL STANDARDS Auditing and Corrective Action § 115.404 Audit corrective action plan. (a) A finding of...

  12. 28 CFR 115.404 - Audit corrective action plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Audit corrective action plan. 115.404 Section 115.404 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PRISON RAPE ELIMINATION ACT NATIONAL STANDARDS Auditing and Corrective Action § 115.404 Audit corrective action plan. (a) A finding of...

  13. 28 CFR 115.404 - Audit corrective action plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Audit corrective action plan. 115.404 Section 115.404 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) PRISON RAPE ELIMINATION ACT NATIONAL STANDARDS Auditing and Corrective Action § 115.404 Audit corrective action plan. (a) A finding of...

  14. 16 CFR 1209.37 - Corrective actions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Corrective actions. 1209.37 Section 1209.37... SAFETY STANDARD FOR CELLULOSE INSULATION Certification § 1209.37 Corrective actions. (a) Test failure. When any test required by § 1209.36 yields failing or unacceptable results, corrective action must be...

  15. USGS Coal Desorption Equipment and a Spreadsheet for Analysis of Lost and Total Gas from Canister Desorption Measurements

    USGS Publications Warehouse

    Barker, Charles E.; Dallegge, Todd A.; Clark, Arthur C.

    2002-01-01

    We have updated a simple polyvinyl chloride plastic canister design by adding internal headspace temperature measurement, and redesigned it so it is made with mostly off-the-shelf components for ease of construction. Using self-closing quick connects, this basic canister is mated to a zero-head manometer to make a simple coalbed methane desorption system that is easily transported in small aircraft to remote localities. This equipment is used to gather timed measurements of pressure, volume and temperature data that are corrected to standard pressure and temperature (STP) and graphically analyzed using an Excel(tm)-based spreadsheet. Used together these elements form an effective, practical canister desorption method.

  16. 75 FR 19944 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  17. Implementation of the evidence review on best practice for confirming the correct placement of nasogastric tube in patients in an acute care hospital.

    PubMed

    Tho, Poh Chi; Mordiffi, Siti; Ang, Emily; Chen, Helen

    2011-03-01

    Nasogastric (NG) tube is a device passed through the gastrointestinal tract of patients for the purpose of feeding, gastric decompression and medication administration. However, a small risk involved in the process is that the tube may be misplaced into the trachea during insertion or may get displaced at a later stage, leading to disastrous results. Recent adverse incidences arising out of the misplacement of NG tube raised concerns among the nursing and medical community and the Patient Safety Officer of the hospital. The Evidence Based Nursing Unit, in collaboration with some of the key nursing leaders in nursing administration, was tasked to explore and institute the current best practice in confirming the correct placement of NG tube. The aim of this project was to institute the best practice to confirm the correct placement of NG tube in patients in an acute care hospital setting. The project comprised of a few stages. The first stage involved reviewing the existing recommendations and guidelines on the methods for checking correct NG tube placement. The second stage involved incorporation of the change of practice into the clinical setting. The final stage was to monitor and evaluate the impact of the new practice on the patients, nurses and other healthcare professionals. Evidence search from guidelines and journals supported the test that used pH indicator instead of the litmus test. There is no evidence that supports the method of auscultation and bubbling to confirm correct NG tube placement in the absence of aspirate. Radiology remains the 'gold standard' for checking correct NG tube placement. The revised method of NG tube placement and workflow was incorporated in the revised Standard Operating Procedures. A total of 17 roadshows were conducted to create awareness regarding the new method amongst the nurses, and the implementation of the revised method and workflow was commenced on 3 November 2008. The initial audit conducted 1 month after the practice change was implemented reported 26 (50%) observations of NG tube feeding in 26 audit wards. The key areas of practice change in feeding when tube placement was confirmed (84.6%) and proper testing of aspirate (76.9%) showed good compliance. The implementation of the change in the practice of confirming the correct placement of the NG tube in patients requires good coordination and a multidisciplinary team approach. © 2011 The Authors. International Journal of Evidence-Based Healthcare © 2011 The Joanna Briggs Institute.

  18. 77 FR 9845 - Reporting of Specified Foreign Financial Assets; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-21

    ... Reporting of Specified Foreign Financial Assets; Correction AGENCY: Internal Revenue Service (IRS). ACTION...), which were published in the Federal Register on Monday, December 19, 2011, relating to reporting of specified foreign financial assets. DATES: Effective Date: This correction is effective February 21, 2012...

  19. 78 FR 15877 - Taxable Medical Devices; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-13

    ... Medical Devices; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correction to final... on the excise tax imposed on the sale of certain medical devices, enacted by the Health Care and Education Reconciliation Act of 2010 in conjunction with the Patient Protection and Affordable Care Act...

  20. Teaching in Correctional Settings

    ERIC Educational Resources Information Center

    de Koning, Mireille; Striedinger, Angelika

    2009-01-01

    In early 2009, Education International conducted a study amongst its member organisations on education in correctional settings in their respective countries. Findings reveal that education in correctional settings and the conditions of teachers working in them vary greatly between regions. Generally speaking, in most regions, but specifically in…

  1. Determination of phenol, m-, o- and p-cresol, p-aminophenol and p-nitrophenol in urine by high-performance liquid chromatography.

    PubMed

    Brega, A; Prandini, P; Amaglio, C; Pafumi, E

    1990-12-28

    A method for the biological monitoring of human exposure to aromatic hydrocarbons, nitrocompounds, amines and phenols has been developed. Phenol, cresols, p-aminophenol, p-nitrophenol and their glucorono- or sulpho-conjugates, were quantified by HPLC; 4-chlorphenol was added as internal standard. After enzymatic hydrolysis, the free compounds were extracted with an organic solvent and analyzed by an isocratic HPLC Perkin Elmer system at ambient temperature and at a flow-rate of 1 ml/min. The column was a reversed-phase Pecosphere 3 x 3 C18 Perkin Elmer; the mobile phase was a 30:70:0.1 (v/v/v) methanol-water-orthophosphoric acid mixture and the chromatogram was monitored at 215 nm. Identification was based on retention time and quantification was performed by automatic peak height determination, corrected for the internal standard. The recovery was ca. 95% for phenol and cresols; 90% for p-nitrophenol; 85% for p-aminophenol; the coefficients of variance were less than 6% within analysis (n = 20) and less than 10% between analysis (n = 20). The detection limits, at a signal/noise ratio of 2, were 0.5 mg/l for phenol and cresols and 1 mg/l for p-aminophenol and p-nitrophenol.

  2. Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Takahashi, Hakuo; Yoshika, Masamichi; Yokoi, Toyohiko

    2013-01-01

    Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E). A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010. The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines. All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines.

  3. Caracterisation, modelisation et validation du transfert radiatif d'atmospheres non standard; impact sur les corrections atmospheriques d'images de teledetection

    NASA Astrophysics Data System (ADS)

    Zidane, Shems

    This study is based on data acquired with an airborne multi-altitude sensor on July 2004 during a nonstandard atmospheric event in the region of Saint-Jean-sur-Richelieu, Quebec. By non-standard atmospheric event we mean an aerosol atmosphere that does not obey the typical monotonic, scale height variation employed in virtually all atmospheric correction codes. The surfaces imaged during this field campaign included a diverse variety of targets : agricultural land, water bodies, urban areas and forests. The multi-altitude approach employed in this campaign allowed us to better understand the altitude dependent influence of the atmosphere over the array of ground targets and thus to better characterize the perturbation induced by a non-standard (smoke) plume. The transformation of the apparent radiance at 3 different altitudes into apparent reflectance and the insertion of the plume optics into an atmospheric correction model permitted an atmospheric correction of the apparent reflectance at the two higher altitudes. The results showed consistency with the apparent validation reflectances derived from the lowest altitude radiances. This approach effectively confirmed the accuracy of our non-standard atmospheric correction approach. This test was particularly relevant at the highest altitude of 3.17 km : the apparent reflectances at this altitude were above most of the plume and therefore represented a good test of our ability to adequately correct for the influence of the perturbation. Standard atmospheric disturbances are obviously taken into account in most atmospheric correction models, but these are based on monotonically decreasing aerosol variations with increasing altitude. When the atmospheric radiation is affected by a plume or a local, non-standard pollution event, one must adapt the existing models to the radiative transfer constraints of the local perturbation and to the reality of the measurable parameters available for ingestion into the model. The main inputs of this study were those normally used in an atmospheric correction : apparent at-sensor radiance and the aerosol optical depth (AOD) acquired using ground-based sunphotometry. The procedure we employed made use of a standard atmospheric correction code (CAM5S, for Canadian Modified 5S, which comes from the 5S radiative transfer model in the visible and near infrared) : however, we also used other parameters and data to adapt and correctly model the special atmospheric situation which affected the multi-altitude images acquired during the St. Jean field campaign. We then developed a modeling protocol for these atmospheric perturbations where auxiliary data was employed to complement our main data-set. This allowed for the development of a robust and simple methodology adapted to this atmospheric situation. The auxiliary data, i.e. meteorological data, LIDAR profiles, various satellite images and sun photometer retrievals of the scattering phase function, were sufficient to accurately model the observed plume in terms of a unusual, vertical distribution. This distribution was transformed into an aerosol optical depth profile that replaced the standard aerosol optical depth profile employed in the CAM5S atmospheric correction model. Based on this model, a comparison between the apparent ground reflectances obtained after atmospheric corrections and validation values of R*(0) obtained from the lowest altitude data showed that the error between the two was less than 0.01 rms. This correction was shown to be a significantly better estimation of the surface reflectance than that obtained using the atmospheric correction model. Significant differences were nevertheless observed in the non-standard solution : these were mainly caused by the difficulties brought about by the acquisition conditions, significant disparities attributable to inconsistencies in the co-sampling / co-registration of different targets from three different altitudes, and possibly modeling errors and / or calibration. There is accordingly room for improvement in our approach to dealing with such conditions. The modeling and forecasting of such a disturbance is explicitly described in this document: our goal in so doing is to permit the establishment of a better protocol for the acquisition of more suitable supporting data. The originality of this study stems from a new approach for incorporating a plume structure into an operational atmospheric correction model and then demonstrating that the approach was a significant improvement over an approach that ignored the perturbations in the vertical profile while employing the correct overall AOD. The profile model we employed was simple and robust but captured sufficient plume detail to achieve significant improvements in atmospheric correction accuracy. The overall process of addressing all the problems encountered in the analysis of our aerosol perturbation helped us to build an appropriate methodology for characterizing such events based on data availability, distributed freely and accessible to the scientific community. This makes our study adaptable and exportable to other types of non-standard atmospheric events. Keywords : non-standard atmospheric perturbation, multi-altitude apparent radiances, smoke plume, Gaussian plume modelization, radiance fit, AOD, CASI

  4. 40 CFR 257.26 - Assessment of corrective measures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Assessment of corrective measures. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.26 Assessment of corrective... protection standards defined under § 257.25 (h) or (i), the owner or operator must initiate an assessment of...

  5. 40 CFR 257.26 - Assessment of corrective measures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Assessment of corrective measures. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.26 Assessment of corrective... protection standards defined under § 257.25 (h) or (i), the owner or operator must initiate an assessment of...

  6. 40 CFR 257.26 - Assessment of corrective measures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Assessment of corrective measures. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.26 Assessment of corrective... protection standards defined under § 257.25 (h) or (i), the owner or operator must initiate an assessment of...

  7. Correcting the Standard Errors of 2-Stage Residual Inclusion Estimators for Mendelian Randomization Studies.

    PubMed

    Palmer, Tom M; Holmes, Michael V; Keating, Brendan J; Sheehan, Nuala A

    2017-11-01

    Mendelian randomization studies use genotypes as instrumental variables to test for and estimate the causal effects of modifiable risk factors on outcomes. Two-stage residual inclusion (TSRI) estimators have been used when researchers are willing to make parametric assumptions. However, researchers are currently reporting uncorrected or heteroscedasticity-robust standard errors for these estimates. We compared several different forms of the standard error for linear and logistic TSRI estimates in simulations and in real-data examples. Among others, we consider standard errors modified from the approach of Newey (1987), Terza (2016), and bootstrapping. In our simulations Newey, Terza, bootstrap, and corrected 2-stage least squares (in the linear case) standard errors gave the best results in terms of coverage and type I error. In the real-data examples, the Newey standard errors were 0.5% and 2% larger than the unadjusted standard errors for the linear and logistic TSRI estimators, respectively. We show that TSRI estimators with modified standard errors have correct type I error under the null. Researchers should report TSRI estimates with modified standard errors instead of reporting unadjusted or heteroscedasticity-robust standard errors. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.

  8. 77 FR 9845 - Reporting of Specified Foreign Financial Assets; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-21

    ... Reporting of Specified Foreign Financial Assets; Correction AGENCY: Internal Revenue Service (IRS), Treasury...), which were published in the Federal Register on Monday, December 19, 2011, relating to the reporting of specified foreign financial assets. DATES: Effective date: This correction is effective February 21, 2012...

  9. 77 FR 41048 - Health Insurance Premium Tax Credit; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... Health Insurance Premium Tax Credit; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... regulations relate to the health insurance premium tax credit enacted by the Patient Protection and Affordable Care Act and the Health Care and Education Reconciliation Act of 2010. DATES: This correction is...

  10. Request for Correction 11001 Toxicological Review of Halogenated Platinum Salts and Platinum Compounds

    EPA Pesticide Factsheets

    Request for Correction by the International Platinum Group Metals Association seeking the correction of information disseminated in the draft EPA document Toxicological Review of Halogenated Platinum Salts and Platinum Compounds: In Support of Summary Information on the Integrated Risk Information System (IRIS).

  11. 76 FR 51878 - Modifications of Certain Derivative Contracts; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ... Modifications of Certain Derivative Contracts; Correction AGENCY: Internal Revenue Service (IRS), Treasury... derivative contracts does not result in an exchange to the nonassigning counterparty for purposes of Sec. 1... derivative contract to another dealer in securities or'' is corrected to read ``or a clearinghouse transfers...

  12. 75 FR 20918 - High-Voltage Continuous Mining Machine Standard for Underground Coal Mines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-22

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration 30 CFR Parts 18 and 75 RIN 1219-AB34 High-Voltage Continuous Mining Machine Standard for Underground Coal Mines Correction In rule document 2010-7309 beginning on page 17529 in the issue of Tuesday, April 6, 2010, make the following correction...

  13. 77 FR 38717 - Updating Regulations Issued Under the Fair Labor Standards Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... DEPARTMENT OF LABOR Wage and Hour Division 29 CFR Parts 531 and 553 Updating Regulations Issued Under the Fair Labor Standards Act CFR Correction In Title 29 of the Code of Federal Regulations, Parts 500 to 899, revised as of July 1, 2011, the following corrections are made: [[Page 38718

  14. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  15. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  16. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  17. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  18. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  19. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  20. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  1. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  2. 16 CFR 1209.37 - Corrective actions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION Certification § 1209.37 Corrective actions. (a) Test failure... insulation product itself. Corrective action may consist of equipment adjustment, equipment repair, equipment...

  3. Thermal Ionization Mass Spectrometry Techniques for the Determination of d34S and D33S

    NASA Astrophysics Data System (ADS)

    Mann, J. L.; Kelly, W. R.

    2006-12-01

    Mass-dependent (MD) and mass-independent (MI) sulfur isotopic compositions are measured by gas source isotope ratio mass spectrometry (GIRMS) using either SO2 or SF6 gas. The variations in sulfur isotopes are used for tracing sources of sulfur and elucidating the sulfur cycle. The recent discovery of MI sulfur isotopic effects provide a tracer for atmospheric processes that may yield insight into the atmospheric sulfur cycle. Determinations of δ^{34}S and Δ^{33}S as well as sulfur concentration in low concentration (ppb) samples are now possible by multi-collector thermal ionization mass spectrometry (MCTIMS) by measuring arsenic sulfide molecular ions (AsS+) using silica gel as an emitter. δ^{34}S is determined using a ^{33}S/^{36}S double spike to correct for instrumental mass fractionation. It is added to the sample before chemical processing which permits the simultaneous determination of the natural MD isotopic fractionation and the sulfur concentration. The addition of the double spike before sample processing has the important additional advantage that any isotopic fractionation that may occur during the chemistry will be removed by the double spike correction procedure. The accuracy and precision of the double spike technique is comparable to modern GIRMS, but requires about a factor of 10 less sample. Δ^{33}S effects can also be measured by MCTIMS on unspiked samples using internal normalization. In GIRMS Δ^{33}S effects are defined by the following equation: Δ^{33}S = δ^{33}S - k δ^{34}S A resolvable effect is governed by both the precision and reproducibility of the δ^{33}S and δ^{34}S measurements and the k value. It is claimed that effects of 0.05 to 0.20 Δ^{33}S units are resolvable. MI effects in mass 33 using MCTIMS are determined on an unspiked sample using internal normalization. Because mass 33 falls between and adjacent to the masses 32 and 34 that are used for correction the interpolation correction is over the smallest possible range. A resolvable Δ^{33}S effect depends only on the precision of the measurement. It is direct in that unlike GIRMS it does not require measurement of δ^{33}S and δ^{34}S or any assumption as to the value of the parameter k. GIRMS could also potentially use the internal normalization procedure to perform direct measurements of Δ^{33}S. The double spike MCTIMS procedure was evaluated by measuring the international standards (IAEA-S-1, S-2, and S-3). The δ^{34}S values (relative to Vienna Canyon Diablo Troilite (VCDT)) determined were 0.32‰ ± 0.04‰ (1σ, n=4) and 0.31‰ ± 0.13‰ (1σ, n=8) for S-1, 22.65‰ ± 0.04‰ (1σ, n=7) and 22.60‰ ± 0.06‰ (1σ, n=5) for S-2, and 32.47‰ ± 0.07‰ (1σ, n=8) for S-3. The uncertainties reported are comparable to or better then those obtained by GIRMS. Δ^{33}S determinations for S-1, also reported relative to VCDT, ranged from -0.67‰ ± 2.2‰ (1σ) to 0.71‰ ± 2.1‰ (1σ) and averaged 0.0028‰ ± 0.55‰ (1σ, n=6) suggesting there is no MI effect (Δ^{33}S=0). Although the MCTIMS procedure requires the use of a mass fractionation law, previous work on MD standards showed that the change in fractionation during data collection was small (2 to 3‰) and thus the correction required was small and unlikely to produce measurable artifacts in Δ^{33}S.

  4. 77 FR 37361 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY: Environmental Protection... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance...

  5. 78 FR 63873 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... Internal Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class... Internal Control Standards. 64 FR 590. The rule added a new part to the Commission's regulations...

  6. 78 FR 11793 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-20

    ... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... NIGC published a final rule in the Federal Register called Minimum Internal Control Standards. 64 FR...

  7. Can a pseudo-Nambu-Goldstone Higgs lead to symmetry non-restoration?

    NASA Astrophysics Data System (ADS)

    Kilic, Can; Swaminathan, Sivaramakrishnan

    2016-01-01

    The calculation of finite temperature contributions to the scalar potential in a quantum field theory is similar to the calculation of loop corrections at zero temperature. In natural extensions of the Standard Model where loop corrections to the Higgs potential cancel between Standard Model degrees of freedom and their symmetry partners, it is interesting to contemplate whether finite temperature corrections also cancel, raising the question of whether a broken phase of electroweak symmetry may persist at high temperature. It is well known that this does not happen in supersymmetric theories because the thermal contributions of bosons and fermions do not cancel each other. However, for theories with same spin partners, the answer is less obvious. Using the Twin Higgs model as a benchmark, we show that although thermal corrections do cancel at the level of quadratic divergences, subleading corrections still drive the system to a restored phase. We further argue that our conclusions generalize to other well-known extensions of the Standard Model where the Higgs is rendered natural by being the pseudo-Nambu-Goldstone mode of an approximate global symmetry.

  8. E-oncology and health portals: instructions and standards for the evaluation, production organisation and use.

    PubMed

    Cognetti, G; Cecere, L

    2003-12-01

    In 2002 the Italian Ministry of Health promoted the institution of a network and a web portal, E-oncology (2), for the seven NHS research institutions specialising in oncology (Istituti di Ricovero e Cura a Carattere Scientifico-IRCCS). One of the aims was to gather and provide information on tumoral pathologies to operators and the public. For an optimum organisation of a health web site it is necessary to comply with the standards internationally used. The World Wide Web Consortium (W3C) has developed guidelines for accessibility and usability of the sites, implemented in Italy through governmental issues. Many international organisations adopt rules and codes of conduct to validate biomedical information and have organised quality portals such as NLM, OMNI, MEDCIRCLE, HON etc. Some terminological standards, such as the MESH thesaurus and UMLS, have been produced by the libraries for a correct management and an effective information retrieval, and are currently used by the most important biomedical web sites. The Dublin Core, metadata standard for the integration of information deriving from heterogeneous archives, has also been developed by the libraries. The easy access to information dims the complex architecture necessary for the construction of a web site. The contribution of different professionals is necessary to guarantee the production of quality medical/health web sites, among them librarians have always been involved with the management of knowledge and their skills are extremely valuable. Furthermore, the libraries' network is essential in order to guarantee universal access to health information, mostly still against payment, and to contribute to overcoming the 'digital divide' and 'second-level digital divide'.

  9. 78 FR 19100 - Noncompensatory Partnership Options

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-29

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9612] RIN 1545-BA53 Noncompensatory Partnership Options Correction In rule document 2013-2259 appearing on pages 7997-8016 in the issue of Tuesday, February 5, 2013, make the following correction: Sec. 1.704-1 [Corrected] In Sec. 1...

  10. 77 FR 41952 - Correction to Modification of Regulations Regarding the Definition of Factual Information and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-17

    ... DEPARTMENT OF COMMERCE International Trade Administration 19 CFR Part 351 Correction to Modification of Regulations Regarding the Definition of Factual Information and Time Limits for Submission of... Commerce. FOR FURTHER INFORMATION CONTACT: Joanna Theiss at (202) 482-5052. Correction On July 10, 2012...

  11. 77 FR 32444 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... the Federal Register called Minimum Internal Control Standards. 64 FR 590. The rule added a new part...

  12. Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods

    NASA Astrophysics Data System (ADS)

    Marchant, T. E.; Joshi, K. D.; Moore, C. J.

    2018-03-01

    Radiotherapy dose calculations based on cone-beam CT (CBCT) images can be inaccurate due to unreliable Hounsfield units (HU) in the CBCT. Deformable image registration of planning CT images to CBCT, and direct correction of CBCT image values are two methods proposed to allow heterogeneity corrected dose calculations based on CBCT. In this paper we compare the accuracy and robustness of these two approaches. CBCT images for 44 patients were used including pelvis, lung and head & neck sites. CBCT HU were corrected using a ‘shading correction’ algorithm and via deformable registration of planning CT to CBCT using either Elastix or Niftyreg. Radiotherapy dose distributions were re-calculated with heterogeneity correction based on the corrected CBCT and several relevant dose metrics for target and OAR volumes were calculated. Accuracy of CBCT based dose metrics was determined using an ‘override ratio’ method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the same image is assumed to be constant for each patient, allowing comparison to the patient’s planning CT as a gold standard. Similar performance is achieved by shading corrected CBCT and both deformable registration algorithms, with mean and standard deviation of dose metric error less than 1% for all sites studied. For lung images, use of deformed CT leads to slightly larger standard deviation of dose metric error than shading corrected CBCT with more dose metric errors greater than 2% observed (7% versus 1%).

  13. The International Polar Year, 2007-2008, an opportunity to focus on infectious diseases in Arctic regions.

    PubMed

    Parkinson, Alan J

    2008-01-01

    On 3 occasions over the past 125 years, scientists from around the world have worked together to organize scientific and exploration activities in polar regions (www.ipy.org). The first International Polar Year (IPY) in 1881-1884 marked the first major coordinated international scientific initiative to collect standardized meteorological and geophysical data in polar regions. Fifteen expeditions led by 12 nations amassed a large amount of data, but the scientific value was diminished by disjointed publication efforts and lack of long-term institutional commitment; lessons were learned and corrected in subsequent polar years. The second IPY began in 1932. Forty-four nations led expeditions in the Arctic and Antarctic, resulting in greater understanding of the aurora, magnetism, and meteorology. Air and marine navigation, radio operations, and weather forecasting were greatly improved as a result. The third IPY, in 1957-58, was renamed the International Geophysical Year and capitalized on technologic advances developed during World War II. Technologic and scientific momentum was redirected toward research, particularly to studies of the upper atmosphere, a legacy that continues to the present day. Notable achievements included launching the first satellite, measurement of atmospheric greenhouse gases, delineating the system of mid-ocean ridges, and confirming the theory of plate tectonics.

  14. Copper and tin isotopic analysis of ancient bronzes for archaeological investigation: development and validation of a suitable analytical methodology.

    PubMed

    Balliana, Eleonora; Aramendía, Maite; Resano, Martin; Barbante, Carlo; Vanhaecke, Frank

    2013-03-01

    Although in many cases Pb isotopic analysis can be relied on for provenance determination of ancient bronzes, sometimes the use of "non-traditional" isotopic systems, such as those of Cu and Sn, is required. The work reported on in this paper aimed at revising the methodology for Cu and Sn isotope ratio measurements in archaeological bronzes via optimization of the analytical procedures in terms of sample pre-treatment, measurement protocol, precision, and analytical uncertainty. For Cu isotopic analysis, both Zn and Ni were investigated for their merit as internal standard (IS) relied on for mass bias correction. The use of Ni as IS seems to be the most robust approach as Ni is less prone to contamination, has a lower abundance in bronzes and an ionization potential similar to that of Cu, and provides slightly better reproducibility values when applied to NIST SRM 976 Cu isotopic reference material. The possibility of carrying out direct isotopic analysis without prior Cu isolation (with AG-MP-1 anion exchange resin) was investigated by analysis of CRM IARM 91D bronze reference material, synthetic solutions, and archaeological bronzes. Both procedures (Cu isolation/no Cu isolation) provide similar δ (65)Cu results with similar uncertainty budgets in all cases (±0.02-0.04 per mil in delta units, k = 2, n = 4). Direct isotopic analysis of Cu therefore seems feasible, without evidence of spectral interference or matrix-induced effect on the extent of mass bias. For Sn, a separation protocol relying on TRU-Spec anion exchange resin was optimized, providing a recovery close to 100 % without on-column fractionation. Cu was recovered quantitatively together with the bronze matrix with this isolation protocol. Isotopic analysis of this Cu fraction provides δ (65)Cu results similar to those obtained upon isolation using AG-MP-1 resin. This means that Cu and Sn isotopic analysis of bronze alloys can therefore be carried out after a single chromatographic separation using TRU-Spec resin. Tin isotopic analysis was performed relying on Sb as an internal standard used for mass bias correction. The reproducibility over a period of 1 month (n = 42) for the mass bias-corrected Sn isotope ratios is in the range of 0.06-0.16 per mil (2 s), for all the ratios monitored.

  15. The fractional diffusion limit of a kinetic model with biochemical pathway

    NASA Astrophysics Data System (ADS)

    Perthame, Benoît; Sun, Weiran; Tang, Min

    2018-06-01

    Kinetic-transport equations that take into account the intracellular pathways are now considered as the correct description of bacterial chemotaxis by run and tumble. Recent mathematical studies have shown their interest and their relations to more standard models. Macroscopic equations of Keller-Segel type have been derived using parabolic scaling. Due to the randomness of receptor methylation or intracellular chemical reactions, noise occurs in the signaling pathways and affects the tumbling rate. Then comes the question to understand the role of an internal noise on the behavior of the full population. In this paper we consider a kinetic model for chemotaxis which includes biochemical pathway with noises. We show that under proper scaling and conditions on the tumbling frequency as well as the form of noise, fractional diffusion can arise in the macroscopic limits of the kinetic equation. This gives a new mathematical theory about how long jumps can be due to the internal noise of the bacteria.

  16. Comparison of experiment with calculations using curvature-corrected zero and two equation turbulence models for a two-dimensional U-duct

    NASA Astrophysics Data System (ADS)

    Monson, D. J.; Seegmiller, H. L.; McConnaughey, P. K.

    1990-06-01

    In this paper experimental measurements are compared with Navier-Stokes calculations using seven different turbulence models for the internal flow in a two-dimensional U-duct. The configuration is representative of many internal flows of engineering interst that experience strong curvature. In an effort to improve agreement, this paper tests several versions of the two-equation k-epsilon turbulence model including the standard version, an extended version with a production range time scale, and a version that includes curvature time scales. Each is tested in its high and low Reynolds number formulations. Calculations using these new models and the original mixing length model are compared here with measurements of mean and turbulence velocities, static pressure and skin friction in the U-duct at two Reynolds numbers. The comparisons show that only the low Reynolds number version of the extended k-epsilon model does a reasonable job of predicting the important features of this flow at both Reynolds numbers tested.

  17. Corrections Officer Candidate Information Booklet and User's Manual. Standards and Training for Corrections Program.

    ERIC Educational Resources Information Center

    California State Board of Corrections, Sacramento.

    This package consists of an information booklet for job candidates preparing to take California's Corrections Officer Examination and a user's manual intended for those who will administer the examination. The candidate information booklet provides background information about the development of the Corrections Officer Examination, describes its…

  18. Using a centrifuge for quality control of pre-wetted lightweight aggregate in internally cured concrete

    NASA Astrophysics Data System (ADS)

    Miller, Albert E.

    Early age shrinkage of cementitious systems can result in an increased potential for cracking which can lead to a reduction in service life. Early age shrinkage cracking can be particularly problematic for high strength concretes, which are often specified due to their high strength and low permeability. However, these high strength concretes frequently exhibit a reduction in the internal relative humidity (RH) due to the hydration reaction (chemical shrinkage) and self-desiccation which results in a bulk shrinkage, termed autogenous shrinkage, which is substantial at early ages. Due to the low permeability of these concretes, standard external curing is not always efficient in addressing this reduction in internal RH since the penetration of water can be limited. Internal curing has been developed to reduce autogenous shrinkage. Internally cured mixtures use internal reservoirs filled with fluid (generally water) that release this fluid at appropriate times to counteract the effects of self-desiccation thereby maintaining a high internal RH. Internally cured concrete is frequently produced in North America using pre-wetted lightweight aggregate. One important aspect associated with preparing quality internally cured concrete is being able to determine the absorbed moisture and surface moisture associated with the lightweight aggregate which enables aggregate moisture corrections to be made for the concrete mixture. This thesis represents work performed to develop a test method using a centrifuge to determine the moisture state of pre-wetted fine lightweight aggregate. The results of the test method are then used in a series of worksheets that were developed to assist field technicians when performing the tests and applying the results to a mixture design. Additionally, research was performed on superabsorbent polymers to assess their ability to be used as an internal curing reservoir.

  19. Development of PET projection data correction algorithm

    NASA Astrophysics Data System (ADS)

    Bazhanov, P. V.; Kotina, E. D.

    2017-12-01

    Positron emission tomography is modern nuclear medicine method used in metabolism and internals functions examinations. This method allows to diagnosticate treatments on their early stages. Mathematical algorithms are widely used not only for images reconstruction but also for PET data correction. In this paper random coincidences and scatter correction algorithms implementation are considered, as well as algorithm of PET projection data acquisition modeling for corrections verification.

  20. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    PubMed Central

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776

  1. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    PubMed

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  2. 78 FR 17155 - Standards for the Growing, Harvesting, Packing, and Holding of Produce for Human Consumption...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ...The Food and Drug Administration (FDA or we) is correcting the preamble to a proposed rule that published in the Federal Register of January 16, 2013. That proposed rule would establish science-based minimum standards for the safe growing, harvesting, packing, and holding of produce, meaning fruits and vegetables grown for human consumption. FDA proposed these standards as part of our implementation of the FDA Food Safety Modernization Act. The document published with several technical errors, including some errors in cross references, as well as several errors in reference numbers cited throughout the document. This document corrects those errors. We are also placing a corrected copy of the proposed rule in the docket.

  3. Computing correct truncated excited state wavefunctions

    NASA Astrophysics Data System (ADS)

    Bacalis, N. C.; Xiong, Z.; Zang, J.; Karaoulanis, D.

    2016-12-01

    We demonstrate that, if a wave function's truncated expansion is small, then the standard excited states computational method, of optimizing one "root" of a secular equation, may lead to an incorrect wave function - despite the correct energy according to the theorem of Hylleraas, Undheim and McDonald - whereas our proposed method [J. Comput. Meth. Sci. Eng. 8, 277 (2008)] (independent of orthogonality to lower lying approximants) leads to correct reliable small truncated wave functions. The demonstration is done in He excited states, using truncated series expansions in Hylleraas coordinates, as well as standard configuration-interaction truncated expansions.

  4. Discussions and decisions of the 2012–2014 International Committee on Taxonomy of Viruses (ICTV) Filoviridae Study Group, January 2012–June 2013

    PubMed Central

    Bukreyev, Alexander A.; Chandran, Kartik; Dolnik, Olga; Dye, John M.; Ebihara, Hideki; Leroy, Eric M.; Mühlberger, Elke; Netesov, Sergey V.; Patterson, Jean L.; Paweska, Janusz T.; Saphire, Erica Ollmann; Smither, Sophie J.; Takada, Ayato; Towner, Jonathan S.; Volchkov, Viktor E.; Warren, Travis K.; Kuhn, Jens H.

    2013-01-01

    The International Committee on Taxonomy of Viruses (ICTV) Filoviridae Study Group prepares proposals on the classification and nomenclature of filoviruses to reflect current knowledge or to correct disagreements with the International Code of Virus Classification and Nomenclature (ICVCN). In recent years, filovirus taxonomy has been corrected and updated, but parts of it remain controversial, and several topics remain to be debated. This article summarizes the decisions and discussion of the currently acting ICTV Filoviridae Study Group since its inauguration in January 2012. PMID:24122154

  5. Influence of non-local thermodynamic equilibrium and Zeeman effects on magnetic equilibrium reconstruction using spectral motional Stark effect diagnostic

    NASA Astrophysics Data System (ADS)

    Reimer, R.; Marchuk, O.; Geiger, B.; Mc Carthy, P. J.; Dunne, M.; Hobirk, J.; Wolf, R.; ASDEX Upgrade Team

    2017-08-01

    The Motional Stark Effect (MSE) diagnostic is a well established technique to infer the local internal magnetic field in fusion plasmas. In this paper, the existing forward model which describes the MSE data is extended by the Zeeman effect, fine-structure, and relativistic corrections in the interpretation of the MSE spectra for different experimental conditions at the tokamak ASDEX Upgrade. The contribution of the non-Local Thermodynamic Equilibrium (non-LTE) populations among the magnetic sub-levels and the Zeeman effect on the derived plasma parameters is different. The obtained pitch angle is changed by 3 ° … 4 ° and by 0 . 5 ° … 1 ° including the non-LTE and the Zeeman effects into the standard statistical MSE model. The total correction is about 4°. Moreover, the variation of the magnetic field strength is significantly changed by 2.2% due to the Zeeman effect only. While the data on the derived pitch angle still could not be tested against the other diagnostics, the results from an equilibrium reconstruction solver confirm the obtained values for magnetic field strength.

  6. Tympanometry in infants: a study of the sensitivity and specificity of 226-Hz and 1,000-Hz probe tones.

    PubMed

    Carmo, Michele Picanço; Costa, Nayara Thais de Oliveira; Momensohn-Santos, Teresa Maria

    2013-10-01

    Introduction For infants under 6 months, the literature recommends 1,000-Hz tympanometry, which has a greater sensitivity for the correct identification of middle ear disorders in this population. Objective To systematically analyze national and international publications found in electronic databases that used tympanometry with 226-Hz and 1,000-Hz probe tones. Data Synthesis Initially, we identified 36 articles in the SciELO database, 11 in the Latin American and Caribbean Literature on the Health Sciences (LILACS) database, 199 in MEDLINE, 0 in the Cochrane database, 16 in ISI Web of Knowledge, and 185 in the Scopus database. We excluded 433 articles because they did not fit the selection criteria, leaving 14 publications that were analyzed in their entirety. Conclusions The 1,000-Hz tone test has greater sensitivity and specificity for the correct identification of tympanometric curve changes. However, it is necessary to clarify the doubts that still exist regarding the use of this test frequency. Improved methods for rating curves, standardization of normality criteria, and the types of curves found in infants should be addressed.

  7. Tympanometry in Infants: A Study of the Sensitivity and Specificity of 226-Hz and 1,000-Hz Probe Tones

    PubMed Central

    Carmo, Michele Picanço; Costa, Nayara Thais de Oliveira; Momensohn-Santos, Teresa Maria

    2013-01-01

    Introduction For infants under 6 months, the literature recommends 1,000-Hz tympanometry, which has a greater sensitivity for the correct identification of middle ear disorders in this population. Objective To systematically analyze national and international publications found in electronic databases that used tympanometry with 226-Hz and 1,000-Hz probe tones. Data Synthesis Initially, we identified 36 articles in the SciELO database, 11 in the Latin American and Caribbean Literature on the Health Sciences (LILACS) database, 199 in MEDLINE, 0 in the Cochrane database, 16 in ISI Web of Knowledge, and 185 in the Scopus database. We excluded 433 articles because they did not fit the selection criteria, leaving 14 publications that were analyzed in their entirety. Conclusions The 1,000-Hz tone test has greater sensitivity and specificity for the correct identification of tympanometric curve changes. However, it is necessary to clarify the doubts that still exist regarding the use of this test frequency. Improved methods for rating curves, standardization of normality criteria, and the types of curves found in infants should be addressed. PMID:25992044

  8. Corrected confidence bands for functional data using principal components.

    PubMed

    Goldsmith, J; Greven, S; Crainiceanu, C

    2013-03-01

    Functional principal components (FPC) analysis is widely used to decompose and express functional observations. Curve estimates implicitly condition on basis functions and other quantities derived from FPC decompositions; however these objects are unknown in practice. In this article, we propose a method for obtaining correct curve estimates by accounting for uncertainty in FPC decompositions. Additionally, pointwise and simultaneous confidence intervals that account for both model- and decomposition-based variability are constructed. Standard mixed model representations of functional expansions are used to construct curve estimates and variances conditional on a specific decomposition. Iterated expectation and variance formulas combine model-based conditional estimates across the distribution of decompositions. A bootstrap procedure is implemented to understand the uncertainty in principal component decomposition quantities. Our method compares favorably to competing approaches in simulation studies that include both densely and sparsely observed functions. We apply our method to sparse observations of CD4 cell counts and to dense white-matter tract profiles. Code for the analyses and simulations is publicly available, and our method is implemented in the R package refund on CRAN. Copyright © 2013, The International Biometric Society.

  9. The Third International Standard for Corticotrophin

    PubMed Central

    Bangham, D. R.; Mussett, M. V.; Stack-Dunne, M. P.

    1962-01-01

    At its meeting in September 1957, the WHO Expert Committee on Biological Standardization agreed with the recommendation of the International Conference on Corticotrophin, held in July 1957, that a new international standard for corticotrophin should be set up, since the Second International Standard was made from crude material and was unsuitable for the assay of the purer preparations of corticotrophin now in general clinical use. In this paper, the authors describe the steps taken to establish the Third International Standard for Corticotrophin, from the preparation and international collaborative assay of the new material to the choice of the ”subcutaneous assay” for deriving the potency. The clinical and pharmacological implications of this choice are discussed. Since the preparation, characterization and exact quantitative assay of standards for corticotrophin are so difficult, several batches of approximately 3500 ampoules were prepared in a similar way from the same material to serve as an international Working Standard. Samples from two batches were included in the collaborative assay and found to have the same potency as the Third Standard. Sufficient ampoules of the Working Standard are available for use as national and laboratory standards. PMID:13966359

  10. Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy

    PubMed Central

    Goodsitt, Mitchell M.; Shenoy, Apeksha; Shen, Jincheng; Howard, David; Schipper, Matthew J.; Wilderman, Scott; Christodoulou, Emmanuel; Chun, Se Young; Dewaraja, Yuni K.

    2014-01-01

    Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa. PMID:24784380

  11. 78 FR 21060 - Appeal Proceedings Before the Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-09

    ... adoption of alternate standards from those required by the Commission's minimum internal control standards... adoption of alternate standards from those required by the Commission's minimum internal control standards... TGRAs' adoption of alternate standards from those required by the Commission's minimum internal control...

  12. Description of cervical cancer mortality in Belgium using Bayesian age-period-cohort models

    PubMed Central

    2009-01-01

    Objective To correct cervical cancer mortality rates for death cause certification problems in Belgium and to describe the corrected trends (1954-1997) using Bayesian models. Method Cervical cancer (cervix uteri (CVX), corpus uteri (CRP), not otherwise specified (NOS) uterus cancer and other very rare uterus cancer (OTH) mortality data were extracted from the WHO mortality database together with population data for Belgium and the Netherlands. Different ICD (International Classification of Diseases) were used over time for death cause certification. In the Netherlands, the proportion of not-otherwise specified uterine cancer deaths was small over large periods and therefore internal reallocation could be used to estimate the corrected rates cervical cancer mortality. In Belgium, the proportion of improperly defined uterus deaths was high. Therefore, the age-specific proportions of uterus cancer deaths that are probably of cervical origin for the Netherlands was applied to Belgian uterus cancer deaths to estimate the corrected number of cervix cancer deaths (corCVX). A Bayesian loglinear Poisson-regression model was performed to disentangle the separate effects of age, period and cohort. Results The corrected age standardized mortality rate (ASMR) decreased regularly from 9.2/100 000 in the mid 1950s to 2.5/100,000 in the late 1990s. Inclusion of age, period and cohort into the models were required to obtain an adequate fit. Cervical cancer mortality increases with age, declines over calendar period and varied irregularly by cohort. Conclusion Mortality increased with ageing and declined over time in most age-groups, but varied irregularly by birth cohort. In global, with some discrete exceptions, mortality decreased for successive generations up to the cohorts born in the 1930s. This decline stopped for cohorts born in the 1940s and thereafter. For the youngest cohorts, even a tendency of increasing risk of dying from cervical cancer could be observed, reflecting increased exposure to risk factors. The fact that this increase was limited for the youngest cohorts could be explained as an effect of screening. Bayesian modeling provided similar results compared to previously used classical Poisson models. However, Bayesian models are more robust for estimating rates when data are sparse (youngest age groups, most recent cohorts) and can be used to for predicting future trends.

  13. SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Renbin; Sánchez-Gallego, José R.; Tremonti, Christy

    2016-01-15

    Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss duemore » to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.« less

  14. SDSS-IV/MaNGA: Spectrophotometric calibration technique

    DOE PAGES

    Yan, Renbin; Tremonti, Christy; Bershady, Matthew A.; ...

    2015-12-21

    Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2'' fibers to obtain resolved spectroscopy over a wide wavelength range of 3600-10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss duemore » to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This then requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Thus, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. In using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.« less

  15. Research and analysis on new test lenses for calibration of focimeters used for measuring contact lenses

    NASA Astrophysics Data System (ADS)

    Zhang, Jiyan; Wang, Liru; Ma, Zhenya

    2006-11-01

    A focimeter is one of the basic ophthalmic instruments used in every optometric practice, and verification of the accuracy and calibration of the instrument are of the utmost importance. For many years the International Standardization for Organization requires that calibrations for all kinds of focimeters shall be accomplished by using test lenses described in ISO 9342:1996. These test lenses must be of high quality and of nominal back vertex power that is known with high accuracy. With the development of science and technology, ISO 9342 was revised in 2005. A new part ISO 9342-2 had been drafted for test lenses used to calibrate focimeters with contact lens measurement, and the original ISO 9342 was turned into the current ISO 9342-1, which could only be used to calibrate fociemters with spectacle lens measurement. As one of the standard drafters, the background for the newly published ISO 9342-2 is introduced in this study, and comparison between test lenses of ISO 9342-1 and ISO 9342-2 is made. Further, the influence of tolerance and uncertainty in design and production of standard test lenses of ISO 9342-2 is analyzed. The paraxial approximation is used to relate the lens parameters with back vertex power and to calculate the uncertainty budget. Moreover, one set of test lenses conforming to ISO 9342-2 is manufactured and experiments are done with it. Results show that test lenses described in ISO 9342-2 can correct the measurement errors of focimeters used for measuring contact lenses well, especially for spherical aberration, and the correction is more effective for spherical contact lenses with high back vertex power.

  16. Improving atomic displacement and replacement calculations with physically realistic damage models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nordlund, Kai; Zinkle, Steven J.; Sand, Andrea E.

    Atomic collision processes are fundamental to numerous advanced materials technologies such as electron microscopy, semiconductor processing and nuclear power generation. Extensive experimental and computer simulation studies over the past several decades provide the physical basis for understanding the atomic-scale processes occurring during primary displacement events. The current international standard for quantifying this energetic particle damage, the Norgett-Robinson-Torrens displacements per atom (NRT-dpa) model, has nowadays several well-known limitations. In particular, the number of radiation defects produced in energetic cascades in metals is only ~1/3 the NRT-dpa prediction, while the number of atoms involved in atomic mixing is about a factor ofmore » 30 larger than the dpa value. Here we propose two new complementary displacement production estimators (athermal recombination corrected dpa, arc-dpa) and atomic mixing (replacements per atom, rpa) functions that extend the NRT-dpa by providing more physically realistic descriptions of primary defect creation in materials and may become additional standard measures for radiation damage quantification.« less

  17. Improving atomic displacement and replacement calculations with physically realistic damage models

    DOE PAGES

    Nordlund, Kai; Zinkle, Steven J.; Sand, Andrea E.; ...

    2018-03-14

    Atomic collision processes are fundamental to numerous advanced materials technologies such as electron microscopy, semiconductor processing and nuclear power generation. Extensive experimental and computer simulation studies over the past several decades provide the physical basis for understanding the atomic-scale processes occurring during primary displacement events. The current international standard for quantifying this energetic particle damage, the Norgett-Robinson-Torrens displacements per atom (NRT-dpa) model, has nowadays several well-known limitations. In particular, the number of radiation defects produced in energetic cascades in metals is only ~1/3 the NRT-dpa prediction, while the number of atoms involved in atomic mixing is about a factor ofmore » 30 larger than the dpa value. Here we propose two new complementary displacement production estimators (athermal recombination corrected dpa, arc-dpa) and atomic mixing (replacements per atom, rpa) functions that extend the NRT-dpa by providing more physically realistic descriptions of primary defect creation in materials and may become additional standard measures for radiation damage quantification.« less

  18. Image-guided intervention in the coagulopathic patient.

    PubMed

    Kohli, Marc; Mayo-Smith, William; Zagoria, Ronald; Sandrasegaran, Kumar

    2016-04-01

    Determining practice parameters for interventional procedures is challenging due to many factors including unreliable laboratory tests to measure bleeding risk, variable usage of standardized terminology for adverse events, poorly defined standards for administration of blood products, and the growing numbers of anticoagulant and antiplatelet medications. We aim to address these and other issues faced by radiologists performing invasive procedures through a review of available literature, and experiential guidance from three academic medical centers. We discuss the significant limitations with respect to using prothrombin-time and international normalized ratio to measure bleeding risk, especially in patients with synthetic defects due to liver function. Factors affecting platelet function including the impact of uremia; recent advances in laboratory testing, including platelet function testing; and thromboelastography are also discussed. A review of the existing literature of fresh-frozen plasma replacement therapy is included. The literature regarding comorbidities affecting coagulation including malignancy, liver failure, and uremia are also reviewed. Finally, the authors present a set of recommendations for laboratory thresholds, corrective transfusions, as well as withholding and restarting medications.

  19. Improving atomic displacement and replacement calculations with physically realistic damage models.

    PubMed

    Nordlund, Kai; Zinkle, Steven J; Sand, Andrea E; Granberg, Fredric; Averback, Robert S; Stoller, Roger; Suzudo, Tomoaki; Malerba, Lorenzo; Banhart, Florian; Weber, William J; Willaime, Francois; Dudarev, Sergei L; Simeone, David

    2018-03-14

    Atomic collision processes are fundamental to numerous advanced materials technologies such as electron microscopy, semiconductor processing and nuclear power generation. Extensive experimental and computer simulation studies over the past several decades provide the physical basis for understanding the atomic-scale processes occurring during primary displacement events. The current international standard for quantifying this energetic particle damage, the Norgett-Robinson-Torrens displacements per atom (NRT-dpa) model, has nowadays several well-known limitations. In particular, the number of radiation defects produced in energetic cascades in metals is only ~1/3 the NRT-dpa prediction, while the number of atoms involved in atomic mixing is about a factor of 30 larger than the dpa value. Here we propose two new complementary displacement production estimators (athermal recombination corrected dpa, arc-dpa) and atomic mixing (replacements per atom, rpa) functions that extend the NRT-dpa by providing more physically realistic descriptions of primary defect creation in materials and may become additional standard measures for radiation damage quantification.

  20. Catatonia Education: Needs Assessment and Brief Online Intervention.

    PubMed

    Cooper, Joseph J; Roig Llesuy, Joan

    2017-06-01

    There are no studies investigating physicians' knowledge of catatonia. The authors aimed to assess and increase physicians' awareness of catatonia. A survey with clinical questions about catatonia was administered, followed by a brief online teaching module about catatonia and a post-education survey. Twenty-one psychiatry residents (response rate, 70%) and 36 internal medicine residents (response rate, 34%) participated in the pre-education survey. Psychiatry residents identified 75% of the correct answers about catatonia, compared to 32% correct by internal medicine residents (p < 0.001). Twenty participants (response rate, 35%) completed the online education module and second survey, which resulted in a significant improvement in correct response rates from 60 to 83% in all the participants (p < 0.001). Residents' baseline knowledge of catatonia is low, particularly among internal medicine residents. A brief online module improved resident physicians' knowledge of catatonia. Educational strategies to improve recognition of catatonia should be implemented.

  1. Internal force corrections with machine learning for quantum mechanics/molecular mechanics simulations.

    PubMed

    Wu, Jingheng; Shen, Lin; Yang, Weitao

    2017-10-28

    Ab initio quantum mechanics/molecular mechanics (QM/MM) molecular dynamics simulation is a useful tool to calculate thermodynamic properties such as potential of mean force for chemical reactions but intensely time consuming. In this paper, we developed a new method using the internal force correction for low-level semiempirical QM/MM molecular dynamics samplings with a predefined reaction coordinate. As a correction term, the internal force was predicted with a machine learning scheme, which provides a sophisticated force field, and added to the atomic forces on the reaction coordinate related atoms at each integration step. We applied this method to two reactions in aqueous solution and reproduced potentials of mean force at the ab initio QM/MM level. The saving in computational cost is about 2 orders of magnitude. The present work reveals great potentials for machine learning in QM/MM simulations to study complex chemical processes.

  2. 75 FR 25319 - Tax Counseling for the Elderly (TCE) Program Availability of Application Packages; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service Tax Counseling for the Elderly (TCE) Program...: Correction to a notice. SUMMARY: This document contains a correction to a notice of the Tax Counseling for... application packages for the 2011 Tax Counseling for the Elderly (TCE) Program. FOR FURTHER INFORMATION...

  3. 76 FR 70057 - Extending Religious and Family Member FICA and FUTA Exceptions to Disregarded Entities; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 301 [TD 9554] RIN 1545-BJ07 Extending Religious and Family Member FICA and FUTA Exceptions to Disregarded Entities; Correction AGENCY...: This document describes a correction to final and temporary regulations (TD 9554) extending the...

  4. 76 FR 76037 - Extending Religious and Family Member FICA and FUTA Exceptions to Disregarded Entities; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-06

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 301 [TD 9554] RIN 1545-BJ07 Extending Religious and Family Member FICA and FUTA Exceptions to Disregarded Entities; Correction AGENCY... correction to final and temporary regulations (TD 9554) extending the exceptions from taxes under the Federal...

  5. 76 FR 71259 - Extending Religious and Family Member FICA and FUTA Exceptions to Disregarded Entities; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-17

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 301 [TD 9554] RIN 1545-BJ07 Extending Religious and Family Member FICA and FUTA Exceptions to Disregarded Entities; Correction AGENCY... correction to final and temporary regulations (TD 9554) extending the exceptions from taxes under the Federal...

  6. 76 FR 7907 - Proposed Collection; Comment Request for Form 1099-K; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... 1099-K; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correction to notice and... by the Department of the Treasury. Currently, the IRS is soliciting comments concerning Form 1099-K... comments for Proposed Collection; Comment Request for Form 1099-K contains an error that may prove to be...

  7. 76 FR 4244 - Hybrid Retirement Plans

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-25

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9505] RIN 1545-BG36 Hybrid Retirement Plans Correction In rule document 2010-25941 beginning on page 64123 in the issue of Tuesday, October 19, 2010, make the following correction: Sec. 1.411(a)(13)-1 [Corrected] On page 64137, in Sec. 1...

  8. 75 FR 44138 - Build-In Gains and Losses Under Section 382(h); Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-28

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 1 [TD 9487] RIN 1545-BG03 Build-In.... ACTION: Correcting amendment. SUMMARY: This document contains correcting amends to IRS' regulations providing guidance regarding the treatment of prepaid income under the built-in gain provisions of section...

  9. 78 FR 31454 - Community Health Needs Assessments for Charitable Hospitals; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1 and 53 [REG-106499-12] RIN 1545-BL30 Community Health Needs Assessments for Charitable Hospitals; Correction Correction In proposed rule document 2013-12013, appearing on pages 29628- 29629 in the issue of Tuesday, May 21, 2013, make...

  10. Improving diagnostic capability for HPV disease internationally within the NIH-NIAID-Division of AIDS Clinical Trial Networks

    PubMed Central

    Godfrey, Catherine C.; Michelow, Pamela M.; Godard, Mandana; Sahasrabuddhe, Vikrant V.; Darden, Janice; Firnhaber, Cynthia S.; Wetherall, Neal T.; Bremer, James; Coombs, Robert W.; Wilkin, Timothy

    2014-01-01

    Objectives To evaluate an external quality assurance (EQA) program for the laboratory diagnosis of human papillomavirus (HPV) disease that was established to improve international research capability within the Division of AIDS at the National Institute of Allergy and Infectious Disease–supported Adult AIDS Clinical Trials Group network. Methods A three-component EQA scheme was devised comprising assessments of diagnostic accuracy of cytotechnologists and pathologists using available EQA packages, review of quality and accuracy of clinical slides from local sites by an outside expert, and HPV DNA detection using the commercially available HPV test kit. Results Seven laboratories and 17 pathologists in Africa, India, and South America participated. EQA scores were suboptimal for standard packages in three of seven laboratories. There was good agreement between the local laboratory and the central reader 70% of the time (90% confidence interval, 42%-98%). Performance on the College of American Pathologists’ HPV DNA testing panel was successful in all laboratories tested. Conclusions The prequalifying EQA round identified correctable issues that will improve the laboratory diagnosis of HPV related cervical disease at the international sites and will provide a mechanism for ongoing education and continuous quality improvement. PMID:24225757

  11. Development and validation of a high throughput assay for the quantification of multiple green tea-derived catechins in human plasma.

    PubMed

    Mawson, Deborah H; Jeffrey, Keon L; Teale, Philip; Grace, Philip B

    2018-06-19

    A rapid, accurate and robust method for the determination of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg) and epigallocatechin gallate (EGCg) concentrations in human plasma has been developed. The method utilises protein precipitation following enzyme hydrolysis, with chromatographic separation and detection using reversed-phase liquid chromatography - tandem mass spectrometry (LC-MS/MS). Traditional issues such as lengthy chromatographic run times, sample and extract stability, and lack of suitable internal standards have been addressed. The method has been evaluated using a comprehensive validation procedure, confirming linearity over appropriate concentration ranges, and inter/intra batch precision and accuracies within suitable thresholds (precisions within 13.8% and accuracies within 12.4%). Recoveries of analytes were found to be consistent between different matrix samples, compensated for using suitable internal markers and within the performance of the instrumentation used. Similarly, chromatographic interferences have been corrected using the internal markers selected. Stability of all analytes in matrix is demonstrated over 32 days and throughout extraction conditions. This method is suitable for high throughput sample analysis studies. This article is protected by copyright. All rights reserved.

  12. Absolute Spectrophotometric Calibration to 1% from the FUV through the near-IR

    NASA Astrophysics Data System (ADS)

    Finley, David

    2006-07-01

    We are requesting additional support to complete the work now being carried out under the Cycle 14 archive program, HST-AR-10654. The most critical component of that effort is an accurate determination of the STIS spectrometer LSF, so that we may correctly model the infill of the Balmer line cores by light redistributed from the wings and adjacent continuum. That is the essential input for obtaining accurate and unbiased effective temperatures and gravities, and hence calibrated fluxes, via line profile fitting of the WD calibration standards. To evaluate the published STIS LSF, we investigated the spectral images of the calibration targets, yielding several significant results: a} the STIS LSF varies significantly; b} existing observation-based spectroscopic LSFs or imaging PSFs are inadequate for deriving suitable spectroscopic LSFs; c} accounting for the PSF/LSF variability will improve spectrophotometric accuracy; d} the LSFs used for model fits must be consistent with the extraction process details; and, e} TinyTim-generated PSFs, with some modifications, provide the most suitable basis for producing the required LSFs that are tailored to each individual spectral observation. Based on our current {greatly improved} state of knowlege of the instrumental effects, we are now requesting additional support to complete the work needed to generate correct LSFs, and then carry out the analyses that were the subject of the original proposal.Our goal is the same: to produce a significant improvement to the existing HST calibration. The current calibration is based on three primary DA white dwarf standards, GD 71, GD 153,and G 191-B2B. The standard fluxes are calculated using NLTE models, with effective temperatures and gravities that were derived from Balmer line fits using LTE models. We propose to improve the accuracy and internal consistency of the calibration by deriving corrected effective temperatures and gravities based on fitting the observed line profiles with updated NLTE models, and including the fit results from multiple STIS spectra, rather than the {usually} 1 or 2 ground-based spectra used previously. We will also determine the fluxes for 5 new, fainter primary or secondary standards, extending the standard V magnitude lower limit from 13.4 to 16.5, and extending the wavelength coverage from 0.1 to 2.5 micron. The goal is to achieve an overall flux accuracy of 1%, which will be needed, for example, for the upcoming supernova survey missions to measure the equation of state of the dark energy that is accelerating the expansion of the universe.

  13. Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method

    ERIC Educational Resources Information Center

    Bellamy, Michael K.

    2010-01-01

    The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…

  14. Fast 3D magnetic resonance fingerprinting for a whole-brain coverage.

    PubMed

    Ma, Dan; Jiang, Yun; Chen, Yong; McGivney, Debra; Mehta, Bhairav; Gulani, Vikas; Griswold, Mark

    2018-04-01

    The purpose of this study was to accelerate the acquisition and reconstruction time of 3D magnetic resonance fingerprinting scans. A 3D magnetic resonance fingerprinting scan was accelerated by using a single-shot spiral trajectory with an undersampling factor of 48 in the x-y plane, and an interleaved sampling pattern with an undersampling factor of 3 through plane. Further acceleration came from reducing the waiting time between neighboring partitions. The reconstruction time was accelerated by applying singular value decomposition compression in k-space. Finally, a 3D premeasured B 1 map was used to correct for the B 1 inhomogeneity. The T 1 and T 2 values of the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI phantom showed a good agreement with the standard values, with an average concordance correlation coefficient of 0.99, and coefficient of variation of 7% in the repeatability scans. The results from in vivo scans also showed high image quality in both transverse and coronal views. This study applied a fast acquisition scheme for a fully quantitative 3D magnetic resonance fingerprinting scan with a total acceleration factor of 144 as compared with the Nyquist rate, such that 3D T 1 , T 2 , and proton density maps can be acquired with whole-brain coverage at clinical resolution in less than 5 min. Magn Reson Med 79:2190-2197, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Successful correction of tibial bone deformity through multiple surgical procedures, liquid nitrogen-pretreated bone tumor autograft, three-dimensional external fixation, and internal fixation in a patient with primary osteosarcoma: a case report.

    PubMed

    Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki

    2015-12-07

    In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.

  16. Sources of Error and the Statistical Formulation of M S: m b Seismic Event Screening Analysis

    NASA Astrophysics Data System (ADS)

    Anderson, D. N.; Patton, H. J.; Taylor, S. R.; Bonner, J. L.; Selby, N. D.

    2014-03-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT), a global ban on nuclear explosions, is currently in a ratification phase. Under the CTBT, an International Monitoring System (IMS) of seismic, hydroacoustic, infrasonic and radionuclide sensors is operational, and the data from the IMS is analysed by the International Data Centre (IDC). The IDC provides CTBT signatories basic seismic event parameters and a screening analysis indicating whether an event exhibits explosion characteristics (for example, shallow depth). An important component of the screening analysis is a statistical test of the null hypothesis H 0: explosion characteristics using empirical measurements of seismic energy (magnitudes). The established magnitude used for event size is the body-wave magnitude (denoted m b) computed from the initial segment of a seismic waveform. IDC screening analysis is applied to events with m b greater than 3.5. The Rayleigh wave magnitude (denoted M S) is a measure of later arriving surface wave energy. Magnitudes are measurements of seismic energy that include adjustments (physical correction model) for path and distance effects between event and station. Relative to m b, earthquakes generally have a larger M S magnitude than explosions. This article proposes a hypothesis test (screening analysis) using M S and m b that expressly accounts for physical correction model inadequacy in the standard error of the test statistic. With this hypothesis test formulation, the 2009 Democratic Peoples Republic of Korea announced nuclear weapon test fails to reject the null hypothesis H 0: explosion characteristics.

  17. Influence of ocean tides on the diurnal and semidiurnal earth rotation variations from VLBI observations

    NASA Astrophysics Data System (ADS)

    Gubanov, V. S.; Kurdubov, S. L.

    2015-05-01

    The International astrogeodetic standard IERS Conventions (2010) contains a model of the diurnal and semidiurnal variations in Earth rotation parameters (ERPs), the pole coordinates and the Universal Time, arising from lunisolar tides in the world ocean. This model was constructed in the mid-1990s through a global analysis of Topex/Poseidon altimetry. The goal of this study is to try to estimate the parameters of this model by processing all the available VLBI observations on a global network of stations over the last 35 years performed within the framework of IVS (International VLBI Service) geodetic programs. The complexity of the problemlies in the fact that the sought-for corrections to the parameters of this model lie within 1 mm and, thus, are at the limit of their detectability by all currently available methods of ground-based positional measurements. This requires applying universal software packages with a high accuracy of reduction calculations and a well-developed system of controlling the simultaneous adjustment of observational data to analyze long series of VLBI observations. This study has been performed with the QUASAR software package developed at the Institute of Applied Astronomy of the Russian Academy of Sciences. Although the results obtained, on the whole, confirm a high accuracy of the basic model in the IERS Conventions (2010), statistically significant corrections that allow this model to be refined have been detected for some harmonics of the ERP variations.

  18. Expanding wave solutions of the Einstein equations that induce an anomalous acceleration into the Standard Model of Cosmology.

    PubMed

    Temple, Blake; Smoller, Joel

    2009-08-25

    We derive a system of three coupled equations that implicitly defines a continuous one-parameter family of expanding wave solutions of the Einstein equations, such that the Friedmann universe associated with the pure radiation phase of the Standard Model of Cosmology is embedded as a single point in this family. By approximating solutions near the center to leading order in the Hubble length, the family reduces to an explicit one-parameter family of expanding spacetimes, given in closed form, that represents a perturbation of the Standard Model. By introducing a comoving coordinate system, we calculate the correction to the Hubble constant as well as the exact leading order quadratic correction to the redshift vs. luminosity relation for an observer at the center. The correction to redshift vs. luminosity entails an adjustable free parameter that introduces an anomalous acceleration. We conclude (by continuity) that corrections to the redshift vs. luminosity relation observed after the radiation phase of the Big Bang can be accounted for, at the leading order quadratic level, by adjustment of this free parameter. The next order correction is then a prediction. Since nonlinearities alone could actuate dissipation and decay in the conservation laws associated with the highly nonlinear radiation phase and since noninteracting expanding waves represent possible time-asymptotic wave patterns that could result, we propose to further investigate the possibility that these corrections to the Standard Model might be the source of the anomalous acceleration of the galaxies, an explanation not requiring the cosmological constant or dark energy.

  19. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy.

    PubMed

    Meisamy, Sina; Hines, Catherine D G; Hamilton, Gavin; Sirlin, Claude B; McKenzie, Charles A; Yu, Huanzhou; Brittain, Jean H; Reeder, Scott B

    2011-03-01

    To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2) = 0.99; slope ± standard deviation = 1.00 ± 0.01, P = .77; intercept ± standard deviation = 0.2% ± 0.1, P = .19). T1-independent chemical shift-based water-fat separation MR imaging methods can accurately quantify fat over the entire liver, by using MR spectroscopy as the reference standard, when T2 correction, spectral modeling of fat, and eddy current correction methods are used. © RSNA, 2011.

  20. Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

    PubMed Central

    Hines, Catherine D. G.; Hamilton, Gavin; Sirlin, Claude B.; McKenzie, Charles A.; Yu, Huanzhou; Brittain, Jean H.; Reeder, Scott B.

    2011-01-01

    Purpose: To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r2 = 0.99; slope ± standard deviation = 1.00 ± 0.01, P = .77; intercept ± standard deviation = 0.2% ± 0.1, P = .19). Conclusion: T1-independent chemical shift–based water-fat separation MR imaging methods can accurately quantify fat over the entire liver, by using MR spectroscopy as the reference standard, when T2* correction, spectral modeling of fat, and eddy current correction methods are used. © RSNA, 2011 PMID:21248233

  1. To recognize the use of international standards for making harmonized regulation of medical devices in Asia-pacific.

    PubMed

    Anand, K; Saini, Ks; Chopra, Y; Binod, Sk

    2010-07-01

    'Medical Devices' include everything from highly sophisticated, computerized, medical equipment, right down to simple wooden tongue depressors. Regulations embody the public expectations for how buildings and facilities are expected to perform and as such represent public policy. Regulators, who develop and enforce regulations, are empowered to act in the public's interest to set this policy and are ultimately responsible to the public in this regard. Standardization contributes to the basic infrastructure that underpins society including health and environment, while promoting sustainability and good regulatory practice. The international organizations that produce International Standards are the International Electrotechnical Commission (IEC), the International Organization for Standardization (ISO), and the International Telecommunication Union (ITU). With the increasing globalization of markets, International Standards (as opposed to regional or national standards) have become critical to the trading process, ensuring a level playing field for exports, and ensuring that imports meet the internationally recognized levels of performance and safety. The development of standards is done in response to sectors and stakeholders that express a clearly established need for them. An industry sector or other stakeholder group typically communicates its requirement for standards to one of the national members. To be accepted for development, a proposed work item must receive a majority support of the participating members, who verify the global relevance of the proposed item. The regulatory authority (RA) should provide a method for the recognition of international voluntary standards and for public notification of such recognition. The process of recognition may vary from country to country. Recognition may occur by periodic publication of lists of standards that a regulatory authority has found will meet the Essential Principles. In conclusion, International standards, such as, basic standards, group standards, and product standards, are a tool for harmonizing regulatory processes, to assure the safety, quality, and performance of medical devices. Standards represent the opinion of experts from all interested parties, including industry, regulators, users, and others.

  2. Vision in high-level football officials.

    PubMed

    Baptista, António Manuel Gonçalves; Serra, Pedro M; McAlinden, Colm; Barrett, Brendan T

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23.9% wear contact lenses when officiating. Clinical vision measures in the football officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual acuity may be improved in around a quarter of officials.

  3. Vision in high-level football officials

    PubMed Central

    Serra, Pedro M.; McAlinden, Colm; Barrett, Brendan T.

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23.9% wear contact lenses when officiating. Clinical vision measures in the football officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual acuity may be improved in around a quarter of officials. PMID:29161310

  4. Atmospheric correction of SeaWiFS imagery for turbid coastal and inland waters.

    PubMed

    Ruddick, K G; Ovidio, F; Rijkeboer, M

    2000-02-20

    The standard SeaWiFS atmospheric correction algorithm, designed for open ocean water, has been extended for use over turbid coastal and inland waters. Failure of the standard algorithm over turbid waters can be attributed to invalid assumptions of zero water-leaving radiance for the near-infrared bands at 765 and 865 nm. In the present study these assumptions are replaced by the assumptions of spatial homogeneity of the 765:865-nm ratios for aerosol reflectance and for water-leaving reflectance. These two ratios are imposed as calibration parameters after inspection of the Rayleigh-corrected reflectance scatterplot. The performance of the new algorithm is demonstrated for imagery of Belgian coastal waters and yields physically realistic water-leaving radiance spectra. A preliminary comparison with in situ radiance spectra for the Dutch Lake Markermeer shows significant improvement over the standard atmospheric correction algorithm. An analysis is made of the sensitivity of results to the choice of calibration parameters, and perspectives for application of the method to other sensors are briefly discussed.

  5. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  6. Bootstrap Standard Errors for Maximum Likelihood Ability Estimates When Item Parameters Are Unknown

    ERIC Educational Resources Information Center

    Patton, Jeffrey M.; Cheng, Ying; Yuan, Ke-Hai; Diao, Qi

    2014-01-01

    When item parameter estimates are used to estimate the ability parameter in item response models, the standard error (SE) of the ability estimate must be corrected to reflect the error carried over from item calibration. For maximum likelihood (ML) ability estimates, a corrected asymptotic SE is available, but it requires a long test and the…

  7. Implementation of standardization in clinical practice: not always an easy task.

    PubMed

    Panteghini, Mauro

    2012-02-29

    As soon as a new reference measurement system is adopted, clinical validation of correctly calibrated commercial methods should take place. Tracing back the calibration of routine assays to a reference system can actually modify the relation of analyte results to existing reference intervals and decision limits and this may invalidate some of the clinical decision-making criteria currently used. To maintain the accumulated clinical experience, the quantitative relationship to the previous calibration system should be established and, if necessary, the clinical decision-making criteria should be adjusted accordingly. The implementation of standardization should take place in a concerted action of laboratorians, manufacturers, external quality assessment scheme organizers and clinicians. Dedicated meetings with manufacturers should be organized to discuss the process of assay recalibration and studies should be performed to obtain convincing evidence that the standardization works, improving result comparability. Another important issue relates to the surveillance of the performance of standardized assays through the organization of appropriate analytical internal and external quality controls. Last but not least, uncertainty of measurement that fits for this purpose must be defined across the entire traceability chain, starting with the available reference materials, extending through the manufacturers and their processes for assignment of calibrator values and ultimately to the final result reported to clinicians by laboratories.

  8. Design and development of a very high resolution thermal imager

    NASA Astrophysics Data System (ADS)

    Kuerbitz, Gunther; Duchateau, Ruediger

    1998-10-01

    The design goal of this project was to develop a thermal imaging system with ultimate geometrical resolution without sacrificing thermal sensitivity. It was necessary to fulfil the criteria for a future advanced video standard. This video standard is the so-called HDTV standard (HDTV High Definition TeleVision). The thermal imaging system is a parallel scanning system working in the 7...11 micrometer spectral region. The detector for that system has to have 576 X n (n number of TDI stages) detector elements taking into account a twofold interlace. It must be carefully optimized in terms of range performance and size of optics entrance pupil as well as producibility and yield. This was done in strong interaction with the detector manufacturer. The 16:9 aspect ratio of the HDTV standard together with the high number of 1920 pixels/line impose high demands on the scanner design in terms of scan efficiency and linearity. As an advanced second generation thermal imager the system has an internal thermal reference. The electronics is fully digitized and comprises circuits for Non Uniformity Correction (NUC), scan conversion, electronic zoom, auto gain and level, edge enhancement, up/down and left/right reversion etc. It can be completely remote-controlled via a serial interface.

  9. Assessment of a Microsoft Kinect-based 3D scanning system for taking body segment girth measurements: a comparison to ISAK and ISO standards.

    PubMed

    Clarkson, Sean; Wheat, Jon; Heller, Ben; Choppin, Simon

    2016-01-01

    Use of anthropometric data to infer sporting performance is increasing in popularity, particularly within elite sport programmes. Measurement typically follows standards set by the International Society for the Advancement of Kinanthropometry (ISAK). However, such techniques are time consuming, which reduces their practicality. Schranz et al. recently suggested 3D body scanners could replace current measurement techniques; however, current systems are costly. Recent interest in natural user interaction has led to a range of low-cost depth cameras capable of producing 3D body scans, from which anthropometrics can be calculated. A scanning system comprising 4 depth cameras was used to scan 4 cylinders, representative of the body segments. Girth measurements were calculated from the 3D scans and compared to gold standard measurements. Requirements of a Level 1 ISAK practitioner were met in all 4 cylinders, and ISO standards for scan-derived girth measurements were met in the 2 larger cylinders only. A fixed measurement bias was identified that could be corrected with a simple offset factor. Further work is required to determine comparable performance across a wider range of measurements performed upon living participants. Nevertheless, findings of the study suggest such a system offers many advantages over current techniques, having a range of potential applications.

  10. Simultaneous quantitative analysis of nine vitamin D compounds in human blood using LC-MS/MS.

    PubMed

    Abu Kassim, Nur Sofiah; Gomes, Fabio P; Shaw, Paul Nicholas; Hewavitharana, Amitha K

    2016-01-01

    It has been suggested that each member of the family of vitamin D compounds may have different function(s). Therefore, selective quantification of each compound is important in clinical research. Development and validation attempts of a simultaneous determination method of 12 vitamin D compounds in human blood using precolumn derivatization followed by LC-MS/MS is described. Internal standard calibration with 12 stable isotope labeled analogs was used to correct for matrix effects in MS detector. Nine vitamin D compounds were quantifiable in blood samples with detection limits within femtomole levels. Serum (compared with plasma) was found to be a more suitable sample type, and protein precipitation (compared with saponification) a more effective extraction method for vitamin D assay.

  11. Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens) (Clostridium welchii Type A Antitoxin)

    PubMed Central

    Evans, D. G.; Perkins, F. T.

    1963-01-01

    The Fifth International Standard Gas-Gangrene Antitoxin (Perfringens) (Clostridium welchii Type A Antitoxin) was prepared from serum from immunized horses. It was freeze-dried in ampoules each containing 1 ml. Seven laboratories collaborated in assaying its potency in terms of the Fourth International Standard by the intravenous inoculation of mice. The geometric mean value, taking the results of all the laboratories, was 270 International Units per ampoule and the maximum variation between laboratories was 15%. In vitro (lecithinase) tests were also done by three laboratories, giving an average of 261 International Units per ampoule. The dry weight contents of ampoules, determined in three laboratories, varied by less than 3%, with an average of 90.35 mg per ampoule. The standard was stable for 120 hours at 56°C. Each ampoule of the Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens) contains 270 International Units, and one International Unit is contained in 0.3346 mg of the International Standard. PMID:14107745

  12. The second international standard for polymyxin B.

    PubMed

    Lightbown, J W; Thomas, A H; Grab, B; Outschoorn, A S

    1973-01-01

    Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard.

  13. The second international standard for polymyxin B*

    PubMed Central

    Lightbown, J. W.; Thomas, A. H.; Grab, B.; Outschoorn, A. S.

    1973-01-01

    Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard. PMID:4350877

  14. A Student Assessment Tool for Standardized Patient Simulations (SAT-SPS): Psychometric analysis.

    PubMed

    Castro-Yuste, Cristina; García-Cabanillas, María José; Rodríguez-Cornejo, María Jesús; Carnicer-Fuentes, Concepción; Paloma-Castro, Olga; Moreno-Corral, Luis Javier

    2018-05-01

    The evaluation of the level of clinical competence acquired by the student is a complex process that must meet various requirements to ensure its quality. The psychometric analysis of the data collected by the assessment tools used is a fundamental aspect to guarantee the student's competence level. To conduct a psychometric analysis of an instrument which assesses clinical competence in nursing students at simulation stations with standardized patients in OSCE-format tests. The construct of clinical competence was operationalized as a set of observable and measurable behaviors, measured by the newly-created Student Assessment Tool for Standardized Patient Simulations (SAT-SPS), which was comprised of 27 items. The categories assigned to the items were 'incorrect or not performed' (0), 'acceptable' (1), and 'correct' (2). 499 nursing students. Data were collected by two independent observers during the assessment of the students' performance at a four-station OSCE with standardized patients. Descriptive statistics were used to summarize the variables. The difficulty levels and floor and ceiling effects were determined for each item. Reliability was analyzed using internal consistency and inter-observer reliability. The validity analysis was performed considering face validity, content and construct validity (through exploratory factor analysis), and criterion validity. Internal reliability and inter-observer reliability were higher than 0.80. The construct validity analysis suggested a three-factor model accounting for 37.1% of the variance. These three factors were named 'Nursing process', 'Communication skills', and 'Safe practice'. A significant correlation was found between the scores obtained and the students' grades in general, as well as with the grades obtained in subjects with clinical content. The assessment tool has proven to be sufficiently reliable and valid for the assessment of the clinical competence of nursing students using standardized patients. This tool has three main components: the nursing process, communication skills, and safety management. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Molecfit: A general tool for telluric absorption correction. II. Quantitative evaluation on ESO-VLT/X-Shooterspectra

    NASA Astrophysics Data System (ADS)

    Kausch, W.; Noll, S.; Smette, A.; Kimeswenger, S.; Barden, M.; Szyszka, C.; Jones, A. M.; Sana, H.; Horst, H.; Kerber, F.

    2015-04-01

    Context. Absorption by molecules in the Earth's atmosphere strongly affects ground-based astronomical observations. The resulting absorption line strength and shape depend on the highly variable physical state of the atmosphere, i.e. pressure, temperature, and mixing ratio of the different molecules involved. Usually, supplementary observations of so-called telluric standard stars (TSS) are needed to correct for this effect, which is expensive in terms of telescope time. We have developed the software package molecfit to provide synthetic transmission spectra based on parameters obtained by fitting narrow ranges of the observed spectra of scientific objects. These spectra are calculated by means of the radiative transfer code LBLRTM and an atmospheric model. In this way, the telluric absorption correction for suitable objects can be performed without any additional calibration observations of TSS. Aims: We evaluate the quality of the telluric absorption correction using molecfit with a set of archival ESO-VLT/X-Shooter visible and near-infrared spectra. Methods: Thanks to the wavelength coverage from the U to the K band, X-Shooter is well suited to investigate the quality of the telluric absorption correction with respect to the observing conditions, the instrumental set-up, input parameters of the code, the signal-to-noise of the input spectrum, and the atmospheric profiles. These investigations are based on two figures of merit, Ioff and Ires, that describe the systematic offsets and the remaining small-scale residuals of the corrections. We also compare the quality of the telluric absorption correction achieved with molecfit to the classical method based on a telluric standard star. Results: The evaluation of the telluric correction with molecfit shows a convincing removal of atmospheric absorption features. The comparison with the classical method reveals that molecfit performs better because it is not prone to the bad continuum reconstruction, noise, and intrinsic spectral features introduced by the telluric standard star. Conclusions: Fitted synthetic transmission spectra are an excellent alternative to the correction based on telluric standard stars. Moreover, molecfit offers wide flexibility for adaption to various instruments and observing sites. http://www.eso.org/sci/software/pipelines/skytools/

  16. Standardized sign-out reduces intern perception of medical errors on the general internal medicine ward.

    PubMed

    Salerno, Stephen M; Arnett, Michael V; Domanski, Jeremy P

    2009-01-01

    Prior research on reducing variation in housestaff handoff procedures have depended on proprietary checkout software. Use of low-technology standardization techniques has not been widely studied. We wished to determine if standardizing the process of intern sign-out using low-technology sign-out tools could reduce perception of errors and missing handoff data. We conducted a pre-post prospective study of a cohort of 34 interns on a general internal medicine ward. Night interns coming off duty and day interns reassuming care were surveyed on their perception of erroneous sign-out data, mistakes made by the night intern overnight, and occurrences unanticipated by sign-out. Trainee satisfaction with the sign-out process was assessed with a 5-point Likert survey. There were 399 intern surveys performed 8 weeks before and 6 weeks after the introduction of a standardized sign-out form. The response rate was 95% for the night interns and 70% for the interns reassuming care in the morning. After the standardized form was introduced, night interns were significantly (p < .003) less likely to detect missing sign-out data including missing important diseases, contingency plans, or medications. Standardized sign-out did not significantly alter the frequency of dropped tasks or missed lab and X-ray data as perceived by the night intern. However, the day teams thought there were significantly less perceived errors on the part of the night intern (p = .001) after introduction of the standardized sign-out sheet. There was no difference in mean Likert scores of resident satisfaction with sign-out before and after the intervention. Standardized written sign-out sheets significantly improve the completeness and effectiveness of handoffs between night and day interns. Further research is needed to determine if these process improvements are related to better patient outcomes.

  17. Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction.

    PubMed

    Tao, Shengzhen; Trzasko, Joshua D; Shu, Yunhong; Weavers, Paul T; Huston, John; Gray, Erin M; Bernstein, Matt A

    2016-06-01

    To describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction. Starting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction. Phantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL-induced coarse-scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries. Noniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534-2544, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. One-dimensional reduction of viscous jets. I. Theory

    NASA Astrophysics Data System (ADS)

    Pitrou, Cyril

    2018-04-01

    We build a general formalism to describe thin viscous jets as one-dimensional objects with an internal structure. We present in full generality the steps needed to describe the viscous jets around their central line, and we argue that the Taylor expansion of all fields around that line is conveniently expressed in terms of symmetric trace-free tensors living in the two dimensions of the fiber sections. We recover the standard results of axisymmetric jets and we report the first and second corrections to the lowest order description, also allowing for a rotational component around the axis of symmetry. When applied to generally curved fibers, the lowest order description corresponds to a viscous string model whose sections are circular. However, when including the first corrections, we find that curved jets generically develop elliptic sections. Several subtle effects imply that the first corrections cannot be described by a rod model since it amounts to selectively discard some corrections. However, in a fast rotating frame, we find that the dominant effects induced by inertial and Coriolis forces should be correctly described by rod models. For completeness, we also recover the constitutive relations for forces and torques in rod models and exhibit a missing term in the lowest order expression of viscous torque. Given that our method is based on tensors, the complexity of all computations has been beaten down by using an appropriate tensor algebra package such as xAct, allowing us to obtain a one-dimensional description of curved viscous jets with all the first order corrections consistently included. Finally, we find a description for straight fibers with elliptic sections as a special case of these results, and recover that ellipticity is dynamically damped by surface tension. An application to toroidal viscous fibers is presented in the companion paper [Pitrou, Phys. Rev. E 97, 043116 (2018), 10.1103/PhysRevE.97.043116].

  19. The satisfactory growth and development at 2 years of age of the INTERGROWTH-21st Fetal Growth Standards cohort support its appropriateness for constructing international standards.

    PubMed

    Villar, José; Cheikh Ismail, Leila; Staines Urias, Eleonora; Giuliani, Francesca; Ohuma, Eric O; Victora, Cesar G; Papageorghiou, Aris T; Altman, Douglas G; Garza, Cutberto; Barros, Fernando C; Puglia, Fabien; Ochieng, Roseline; Jaffer, Yasmin A; Noble, Julia A; Bertino, Enrico; Purwar, Manorama; Pang, Ruyan; Lambert, Ann; Chumlea, Cameron; Stein, Alan; Fernandes, Michelle; Bhutta, Zulfiqar A; Kennedy, Stephen H

    2018-02-01

    The World Health Organization recommends that human growth should be monitored with the use of international standards. However, in obstetric practice, we continue to monitor fetal growth using numerous local charts or equations that are based on different populations for each body structure. Consistent with World Health Organization recommendations, the INTERGROWTH-21 st Project has produced the first set of international standards to date pregnancies; to monitor fetal growth, estimated fetal weight, Doppler measures, and brain structures; to measure uterine growth, maternal nutrition, newborn infant size, and body composition; and to assess the postnatal growth of preterm babies. All these standards are based on the same healthy pregnancy cohort. Recognizing the importance of demonstrating that, postnatally, this cohort still adhered to the World Health Organization prescriptive approach, we followed their growth and development to the key milestone of 2 years of age. The purpose of this study was to determine whether the babies in the INTERGROWTH-21 st Project maintained optimal growth and development in childhood. In the Infant Follow-up Study of the INTERGROWTH-21 st Project, we evaluated postnatal growth, nutrition, morbidity, and motor development up to 2 years of age in the children who contributed data to the construction of the international fetal growth, newborn infant size and body composition at birth, and preterm postnatal growth standards. Clinical care, feeding practices, anthropometric measures, and assessment of morbidity were standardized across study sites and documented at 1 and 2 years of age. Weight, length, and head circumference age- and sex-specific z-scores and percentiles and motor development milestones were estimated with the use of the World Health Organization Child Growth Standards and World Health Organization milestone distributions, respectively. For the preterm infants, corrected age was used. Variance components analysis was used to estimate the percentage variability among individuals within a study site compared with that among study sites. There were 3711 eligible singleton live births; 3042 children (82%) were evaluated at 2 years of age. There were no substantive differences between the included group and the lost-to-follow up group. Infant mortality rate was 3 per 1000; neonatal mortality rate was 1.6 per 1000. At the 2-year visit, the children included in the INTERGROWTH-21 st Fetal Growth Standards were at the 49th percentile for length, 50th percentile for head circumference, and 58th percentile for weight of the World Health Organization Child Growth Standards. Similar results were seen for the preterm subgroup that was included in the INTERGROWTH-21 st Preterm Postnatal Growth Standards. The cohort overlapped between the 3rd and 97th percentiles of the World Health Organization motor development milestones. We estimated that the variance among study sites explains only 5.5% of the total variability in the length of the children between birth and 2 years of age, although the variance among individuals within a study site explains 42.9% (ie, 8 times the amount explained by the variation among sites). An increase of 8.9 cm in adult height over mean parental height is estimated to occur in the cohort from low-middle income countries, provided that children continue to have adequate health, environmental, and nutritional conditions. The cohort enrolled in the INTERGROWTH-21 st standards remained healthy with adequate growth and motor development up to 2 years of age, which supports its appropriateness for the construction of international fetal and preterm postnatal growth standards. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  20. Pose determination of a blade implant in three dimensions from a single two-dimensional radiograph.

    PubMed

    Toti, Paolo; Barone, Antonio; Marconcini, Simone; Menchini-Fabris, Giovanni Battista; Martuscelli, Ranieri; Covani, Ugo

    2018-05-01

    The aim of the study was to introduce a mathematical method to estimate the correct pose of a blade by evaluating the radiographic features obtained from a single two-dimensional image. Blade-form implant bed preparation was performed using the piezosurgery device, and placement was attained with the use of magnetic mallet. The pose determination of the blade was described by means of three consecutive rotations defined by three angles of orientation (triplet φ, θ and ψ). Retrospective analysis on periapical radiographs was performed. This method was used to compare implant (axial length along the marker, i.e. the implant structure) vs angular correction factor (a trigonometric function of the triplet). The accuracy of the method was tested by generating two-dimensional radiographic simulations of the blades, which were then compared with the images of the implants as appearing on the real radiographs. Two patients had to be excluded from further evaluation because the values of the estimated pose angles showed a too-wide range to be effective for a good standardization of serial radiographs: intrapatient range from baseline to 1-year survey was > of a threshold determined by the clinicians (30°). The linear dependence between implant (CF°) and angular correction factor (CF^) was estimated by a robust linear regression, yielding the following coefficients: slope, 0.908; intercept, -0.092; and coefficient of determination, 0.924. The absolute error in accuracy was -0.29 ± 4.35, 0.23 ± 3.81 and 0.64 ± 1.18°, respectively, for the angles φ, θ and ψ. The present theoretical and experimental study established the possibility of determining, a posteriori, a unique triplet of angles (φ, θ and ψ) which described the pose of a blade upon a single two-dimensional radiograph, and of suggesting a method to detect cases in which the standardized geometric projection failed. The angular correction of the bone level yielded results very close to those obtained with an internal marker related to the implant length.

  1. The Measurement and Correction of the Periodic Error of the LX200-16 Telescope Driving System

    NASA Astrophysics Data System (ADS)

    Jeong, Jang Hae; Lee, Young Sam; Lee, Chung Uk

    2000-06-01

    We examined and corrected the periodic error of the LX200-16 Telescope driving system of Chungbuk National University Campus Observatory. Before correcting, the standard deviation of the periodic error in the direction of East-West was = 7.''2. After correcting,we found that the periodic error was reduced to = 1.''2.

  2. High precision isotope ratio measurements of mercury isotopes in cinnabar ores using multi-collector inductively coupled plasma mass spectrometry.

    PubMed

    Hintelmann, Holger; Lu, ShengYong

    2003-06-01

    Variations in Hg isotope ratios in cinnabar ores obtained from different countries were detected by high precision isotope ratio measurements using multi-collector inductively coupled mass spectrometry (MC-ICP-MS). Values of delta198/202Hg varied from 0.0-1.3 percent per thousand relative to a NIST SRM 1641d Hg solution. The typical external uncertainty of the delta values was 0.06 to 0.26 percent per thousand. Hg was introduced into the plasma as elemental Hg after reduction by sodium borohydride. A significant fractionation of lead isotopes was observed during the simultaneous generation of lead hydride, preventing normalization of the Hg isotope ratios using the measured 208/206Pb ratio. Hg ratios were instead corrected employing the simultaneously measured 205/203T1 ratio. Using a 10 ng ml(-1) Hg solution and 10 min of sampling, introducing 60 ng of Hg, the internal precision of the isotope ratio measurements was as low as 14 ppm. Absolute Hg ratios deviated from the representative IUPAC values by approximately 0.2% per u. This observation is explained by the inadequacy of the exponential law to correct for mass bias in MC-ICP-MS measurements. In the absence of a precisely characterized Hg isotope ratio standard, we were not able to determine unambiguously the absolute Hg ratios of the ore samples, highlighting the urgent need for certified standard materials.

  3. Observational intensity bias associated with illness adjustment: cross sectional analysis of insurance claims

    PubMed Central

    Staiger, Douglas O; Sharp, Sandra M; Gottlieb, Daniel J; Bevan, Gwyn; McPherson, Klim; Welch, H Gilbert

    2013-01-01

    Objective To determine the bias associated with frequency of visits by physicians in adjusting for illness, using diagnoses recorded in administrative databases. Setting Claims data from the US Medicare program for services provided in 2007 among 306 US hospital referral regions. Design Cross sectional analysis. Participants 20% sample of fee for service Medicare beneficiaries residing in the United States in 2007 (n=5 153 877). Main outcome measures The effect of illness adjustment on regional mortality and spending rates using standard and visit corrected illness methods for adjustment. The standard method adjusts using comorbidity measures based on diagnoses listed in administrative databases; the modified method corrects these measures for the frequency of visits by physicians. Three conventions for measuring comorbidity are used: the Charlson comorbidity index, Iezzoni chronic conditions, and hierarchical condition categories risk scores. Results The visit corrected Charlson comorbidity index explained more of the variation in age, sex, and race mortality across the 306 hospital referral regions than did the standard index (R2=0.21 v 0.11, P<0.001) and, compared with sex and race adjusted mortality, reduced regional variation, whereas adjustment using the standard Charlson comorbidity index increased it. Although visit corrected and age, sex, and race adjusted mortality rates were similar in hospital referral regions with the highest and lowest fifths of visits, adjustment using the standard index resulted in a rate that was 18% lower in the highest fifth (46.4 v 56.3 deaths per 1000, P<0.001). Age, sex, and race adjusted spending as well as visit corrected spending was more than 30% greater in the highest fifth of visits than in the lowest fifth, but only 12% greater after adjustment using the standard index. Similar results were obtained using the Iezzoni and the hierarchical condition categories conventions for measuring comorbidity. Conclusion The rates of visits by physicians introduce substantial bias when regional mortality and spending rates are adjusted for illness using comorbidity measures based on the observed number of diagnoses recorded in Medicare’s administrative database. Adjusting without correction for regional variation in visit rates tends to make regions with high rates of visits seem to have lower mortality and lower costs, and vice versa. Visit corrected comorbidity measures better explain variation in age, sex, and race mortality than observed measures, and reduce observational intensity bias. PMID:23430282

  4. Long-term reproducibility of phantom signal intensities in nonuniformity corrected STIR-MRI examinations of skeletal muscle.

    PubMed

    Viddeleer, Alain R; Sijens, Paul E; van Ooijen, Peter M A; Kuypers, Paul D L; Hovius, Steven E R; Oudkerk, Matthijs

    2009-08-01

    Nerve regeneration could be monitored by comparing MRI image intensities in time, as denervated muscles display increased signal intensity in STIR sequences. In this study long-term reproducibility of STIR image intensity was assessed under clinical conditions and the required image intensity nonuniformity correction was improved by using phantom scans obtained at multiple positions. Three-dimensional image intensity nonuniformity was investigated in phantom scans. Next, over a three-year period, 190 clinical STIR hand scans were obtained using a standardized acquisition protocol, and corrected for intensity nonuniformity by using the results of phantom scanning. The results of correction with 1, 3, and 11 phantom scans were compared. The image intensities in calibration tubes close to the hands were measured every time to determine the reproducibility of our method. With calibration, the reproducibility of STIR image intensity improved from 7.8 to 6.4%. Image intensity nonuniformity correction with 11 phantom scans gave significantly better results than correction with 1 or 3 scans. The image intensities in clinical STIR images acquired at different times can be compared directly, provided that the acquisition protocol is standardized and that nonuniformity correction is applied. Nonuniformity correction is preferably based on multiple phantom scans.

  5. Afghanistan: U.S. Rule of Law and Justice Sector Assistance

    DTIC Science & Technology

    2010-11-09

    Sector Support Program ( JSSP ) and Corrections System Support Program (CSSP); • U.S. Agency for International Development’s (USAID’s) formal and informal...Sector Support Program ( JSSP )........................................................................ 28 Corrections System Support Program (CSSP...programs are the Judicial Sector Support Program ( JSSP ), the Corrections System Support Program (CSSP), the ROL Stabilization (RLS) Program, and the

  6. 26 CFR 601.105 - Examination of returns and claims for refund, credit or abatement; determination of correct tax...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., credit or abatement; determination of correct tax liability. 601.105 Section 601.105 Internal Revenue... abatement; determination of correct tax liability. (a) Processing of returns. When the returns are filed in... made for the payment of any additional tax so resulting, or refund is made of any overpayment. Returns...

  7. L'application de l'appareil Suvaglingua de correction phonetique a l'enseignement de l'espagnol aux francophones (The Use of the Suvaglingua Synthesizer for Phonetic Correction in Spanish Courses for French Speakers)

    ERIC Educational Resources Information Center

    Sarmiento, Jose; And Others

    1974-01-01

    Describes the use of the verbo-tonal method of phonetic correction and the Suvaglingua synthesizer in Spanish courses at the International School of Interpreters at Mons, France. (Text is in French.) (PMP)

  8. 22 CFR 1101.12 - Request to correct or amend a record.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 2 2012-04-01 2009-04-01 true Request to correct or amend a record. 1101.12 Section 1101.12 Foreign Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION PRIVACY ACT OF 1974 § 1101.12 Request to correct or amend a record. (a) Any...

  9. Correction to: A national cohort study on pediatric Behçet's disease: cross-sectional data from an Italian registry.

    PubMed

    Gallizzi, Romina; Pidone, Caterina; Cantarini, Luca; Finetti, Martina; Cattalini, Marco; Filocamo, Giovanni; Insalaco, Antonella; Rigante, Donato; Consolini, Rita; Maggio, Maria Cristina; Civino, Adele; Martino, Silvana; Olivieri, Alma Nunzia; Fabio, Giovanna; Pastore, Serena; Mauro, Angela; Sutera, Diana; Trimarchi, Giuseppe; Ruperto, Nicolino; Gattorno, Marco; Cimaz, Rolando

    2018-04-23

    Following publication of the original article [1], the authors reported that the names of two institutional authors - EUROFEVER and the Paediatric Rheumatology International Trials Organisation (PRINTO) - had been unintentionally omitted in the final online version of the manuscript. The corrected author list is shown in this Correction..

  10. Extended internal standard method for quantitative 1H NMR assisted by chromatography (EIC) for analyte overlapping impurity on 1H NMR spectra.

    PubMed

    Saito, Naoki; Kitamaki, Yuko; Otsuka, Satoko; Yamanaka, Noriko; Nishizaki, Yuzo; Sugimoto, Naoki; Imura, Hisanori; Ihara, Toshihide

    2018-07-01

    We devised a novel extended internal standard method of quantitative 1 H NMR (qNMR) assisted by chromatography (EIC) that accurately quantifies 1 H signal areas of analytes, even when the chemical shifts of the impurity and analyte signals overlap completely. When impurity and analyte signals overlap in the 1 H NMR spectrum but can be separated in a chromatogram, the response ratio of the impurity and an internal standard (IS) can be obtained from the chromatogram. If the response ratio can be converted into the 1 H signal area ratio of the impurity and the IS, the 1 H signal area of the analyte can be evaluated accurately by mathematically correcting the contributions of the 1 H signal area of the impurity overlapping the analyte in the 1 H NMR spectrum. In this study, gas chromatography and liquid chromatography were used. We used 2-chlorophenol and 4-chlorophenol containing phenol as an impurity as examples in which impurity and analyte signals overlap to validate and demonstrate the EIC, respectively. Because the 1 H signals of 2-chlorophenol and phenol can be separated in specific alkaline solutions, 2-chlorophenol is suitable to validate the EIC by comparing analytical value obtained by the EIC with that by only qNMR under the alkaline condition. By the EIC, the purity of 2-chlorophenol was obtained with a relative expanded uncertainty (k = 2) of 0.24%. The purity matched that obtained under the alkaline condition. Furthermore, the EIC was also validated by evaluating the phenol content with the absolute calibration curve method by gas chromatography. Finally, we demonstrated that the EIC was possible to evaluate the purity of 4-chlorophenol, with a relative expanded uncertainty (k = 2) of 0.22%, which was not able to be separated from the 1 H signal of phenol under any condition. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Correction of Near-infrared High-resolution Spectra for Telluric Absorption at 0.90–1.35 μm

    NASA Astrophysics Data System (ADS)

    Sameshima, Hiroaki; Matsunaga, Noriyuki; Kobayashi, Naoto; Kawakita, Hideyo; Hamano, Satoshi; Ikeda, Yuji; Kondo, Sohei; Fukue, Kei; Taniguchi, Daisuke; Mizumoto, Misaki; Arai, Akira; Otsubo, Shogo; Takenaka, Keiichi; Watase, Ayaka; Asano, Akira; Yasui, Chikako; Izumi, Natsuko; Yoshikawa, Tomohiro

    2018-07-01

    We report a method of correcting a near-infrared (0.90–1.35 μm) high-resolution (λ/Δλ ∼ 28,000) spectrum for telluric absorption using the corresponding spectrum of a telluric standard star. The proposed method uses an A0 V star or its analog as a standard star from which on the order of 100 intrinsic stellar lines are carefully removed with the help of a reference synthetic telluric spectrum. We find that this method can also be applied to feature-rich objects having spectra with heavily blended intrinsic stellar and telluric lines and present an application to a G-type giant using this approach. We also develop a new diagnostic method for evaluating the accuracy of telluric correction and use it to demonstrate that our method achieves an accuracy better than 2% for spectral parts for which the atmospheric transmittance is as low as ∼20% if telluric standard stars are observed under the following conditions: (1) the difference in airmass between the target and the standard is ≲ 0.05; and (2) that in time is less than 1 hr. In particular, the time variability of water vapor has a large impact on the accuracy of telluric correction and minimizing the difference in time from that of the telluric standard star is important especially in near-infrared high-resolution spectroscopic observation.

  12. Toward Joint Hypothesis-Tests Seismic Event Screening Analysis: Ms|mb and Event Depth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Dale; Selby, Neil

    2012-08-14

    Well established theory can be used to combine single-phenomenology hypothesis tests into a multi-phenomenology event screening hypothesis test (Fisher's and Tippett's tests). Commonly used standard error in Ms:mb event screening hypothesis test is not fully consistent with physical basis. Improved standard error - Better agreement with physical basis, and correctly partitions error to include Model Error as a component of variance, correctly reduces station noise variance through network averaging. For 2009 DPRK test - Commonly used standard error 'rejects' H0 even with better scaling slope ({beta} = 1, Selby et al.), improved standard error 'fails to rejects' H0.

  13. Replacement of the International Standard for Tetanus Antitoxin and the Use of the Standard in the Flocculation Test

    PubMed Central

    Spaun, J.; Lyng, J.

    1970-01-01

    Since 1935 the International Unit for Tetanus Antitoxin has been defined as the activity contained in a certain weight of the first International Standard for Tetanus Antitoxin. As stocks of this standard had become depleted, 11 laboratories in 8 countries were requested to participate in a collaborative assay of a preparation proposed as a replacement. The assay results were analysed and presented to the WHO Expert Committee on Biological Standardization in 1969 which established the preparation studied as the second International Standard for Tetanus Antitoxin and defined the International Unit for Tetanus Antitoxin as the activity contained in 0.03384 mg of the second International Standard for Tetanus Antitoxin. This definition would ensure the continuity of the size of this international unit. The analysis of the collaborative studies also showed that the second International Standard for Tetanus Antitoxin has suitable properties for use in the flocculation test for the determination of the antigen content of tetanus toxoids in Lf values. The designation Lf-equivalent is described and the problems relating to the use of this term for the expression of results of in vitro assays are analysed in relation to the use of international units for expressing results of in vivo assays. As the second International Standard for Tetanus Antitoxin has an in vivo/in vitro ratio of 1.4, the Lf-equivalent of this antitoxin is 1.4 times less than its unitage. PMID:5310949

  14. Deductive derivation and turing-computerization of semiparametric efficient estimation.

    PubMed

    Frangakis, Constantine E; Qian, Tianchen; Wu, Zhenke; Diaz, Ivan

    2015-12-01

    Researchers often seek robust inference for a parameter through semiparametric estimation. Efficient semiparametric estimation currently requires theoretical derivation of the efficient influence function (EIF), which can be a challenging and time-consuming task. If this task can be computerized, it can save dramatic human effort, which can be transferred, for example, to the design of new studies. Although the EIF is, in principle, a derivative, simple numerical differentiation to calculate the EIF by a computer masks the EIF's functional dependence on the parameter of interest. For this reason, the standard approach to obtaining the EIF relies on the theoretical construction of the space of scores under all possible parametric submodels. This process currently depends on the correctness of conjectures about these spaces, and the correct verification of such conjectures. The correct guessing of such conjectures, though successful in some problems, is a nondeductive process, i.e., is not guaranteed to succeed (e.g., is not computerizable), and the verification of conjectures is generally susceptible to mistakes. We propose a method that can deductively produce semiparametric locally efficient estimators. The proposed method is computerizable, meaning that it does not need either conjecturing, or otherwise theoretically deriving the functional form of the EIF, and is guaranteed to produce the desired estimates even for complex parameters. The method is demonstrated through an example. © 2015, The International Biometric Society.

  15. Terms used for isolation practices by nurses at an academic medical center

    PubMed Central

    Landers, Timothy; McWalters, Jessica; Behta, Maryam; Bufe, Gina; Ross, Barbara; Vawdrey, David K.; Larson, Elaine

    2010-01-01

    Aim This paper is a report of a study to determine if the terms used by nurses to describe isolation precautions are associated with correct identification of required personal protective equipment. Background Isolation measures are important in the prevention of health care-associated infections. The terms used to describe categories of isolation have changed in response to new pathogens and with advances in infection prevention. Methods For three months in2009, nurses from an academic medical center on the East Coast of the United States of America completed a survey consisting of ten clinical scenarios which asked about recommended personal protective equipment and for the name of the recommended isolation type. Correct identification of required personal protective equipment was compared to use of an approved isolation category term, controlling for infection knowledge and demographic variables. Results Three hundred and seventeen nurses gave responses to2, 215 clinical scenarios. Use of non-approved category terms was associated with statistically significantly lower rates of correct personal protective equipment identification compared to use of an approved term (62.2% vs. 77.8%; p<.001). Specific PPE was also selected for use when not indicated--including gowns (42%), N-95 respirators (13%), fluid shield masks(13%) and sterile gloves (6%). Conclusion Inconsistent terminology for isolation precautions may contribute to variations in practice. Adoption of internationally-accepted and standardized category terms may improve adherence to these precautions. PMID:20722801

  16. 25 CFR 542.14 - What are the minimum internal control standards for the cage?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for the cage? 542.14 Section 542.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.14 What are the minimum internal control standards for the cage? (a) Computer applications. For...

  17. 25 CFR 543.8 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....

  18. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

  19. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

  20. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

Top