Sert, Şenol
2013-07-01
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal standard for the internal standardization method. The robust conditions were evaluated using applied radiofrequency power, nebulizer argon gas flow rate, and sample uptake flow rate by considering the intensity ratio of the Mg(II) 280.270 nm and Mg(I) 285.213 nm lines. Analytical characterization of method was assessed by limit of detection and relative standard deviation values. The certificated reference soil sample IAEA S-8 was analyzed, and the uranium determination at 367.007 nm with internal standardization using Sm at 359.260 nm has been shown to improve accuracy compared with other methods. The developed method was used for real uranium ore sample analysis.
Standard methods for sampling freshwater fishes: Opportunities for international collaboration
Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D. S.; Lester, Nigel P.; Porath, Mark T.; Winfield, Ian J.
2017-01-01
With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by state and federal agencies, universities, nongovernmental organizations, and consulting businesses. Currently, standardization is practiced mostly in North America and Europe. Participants described how standardization has been important for management of long-term data sets, promoting fundamental scientific understanding, and assessing efficacy of large spatial scale management strategies. Academics indicated that standardization has been useful in fisheries education because time previously used to teach how sampling methods are developed is now more devoted to diagnosis and treatment of problem fish communities. Researchers reported that standardization allowed increased sample size for method validation and calibration. Group consensus was to retain continental standards where they currently exist but to further explore international and intercontinental standardization, specifically identifying where synergies and bridges exist, and identify means to collaborate with scientists where standardization is limited but interest and need occur.
Zhang, Shuai; Li, PeiPei; Yan, Zhongyong; Long, Ju; Zhang, Xiaojun
2017-03-01
An ultraperformance liquid chromatography-quadrupole time-of-flight high-resolution mass spectrometry method was developed and validated for the determination of nitrofurazone metabolites. Precolumn derivatization with 2,4-dinitrophenylhydrazine and p-dimethylaminobenzaldehyde as an internal standard was used successfully to determine the biomarker 5-nitro-2-furaldehyde. In negative electrospray ionization mode, the precise molecular weights of the derivatives were 320.0372 for the biomarker and 328.1060 for the internal standard (relative error 1.08 ppm). The matrix effect was evaluated and the analytical characteristics of the method and derivatization reaction conditions were validated. For comparison purposes, spiked samples were tested by both internal and external standard methods. The results show high precision can be obtained with p-dimethylaminobenzaldehyde as an internal standard for the identification and quantification of nitrofurazone metabolites in complex biological samples. Graphical Abstract A simplified preparation strategy for biological samples.
Internal Standards: A Source of Analytical Bias For Volatile Organic Analyte Determinations
The use of internal standards in the determination of volatile organic compounds as described in SW-846 Method 8260C introduces a potential for bias in results once the internal standards (ISTDs) are added to a sample for analysis. The bias is relative to the dissimilarity betw...
7 CFR 51.485 - Good internal quality.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Good internal quality. 51.485 Section 51.485... STANDARDS) United States Standards for Grades of Cantaloups 1 Definitions § 51.485 Good internal quality. Good internal quality means that the combined juice from the edible portion of a sample of cantaloups...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colle, R.; Unterweger, M.P.; Hodge, P.A.
1996-01-01
As part of an international {sup 222}Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (blind) {sup 222}Rn concentrations that could be related to US national standards. The standardized sample additions were obtained with a calibrated {sup 226}Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized {sup 222}Rn activity concentrations for the intercomparisonmore » ranged from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3} (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6% to 13%. This paper describes the calibration and methodology for the standardized sample additions.« less
Collé, R.; Unterweger, M. P.; Hodge, P. A.; Hutchinson, J. M. R.
1996-01-01
As part of an international 222Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (“blind”) 222Rn concentrations that could be related to U.S. national standards. The standardized sample additions were obtained with a calibrated 226Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized 222Rn activity concentrations for the intercomparison ranged from approximately 2.5 Bq · m−3 to 35 Bq · m−3 (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6 % to 13 %. This paper describes the calibration and methodology for the standardized sample additions. PMID:27805090
ERIC Educational Resources Information Center
Colombani, Olivier; Langelier, Ophelie; Martwong, Ekkachai; Castignolles, Patrice
2011-01-01
The use of an internal standard is a conventional and convenient way to monitor the conversion of one or several monomers during a controlled radical polymerization. However, the validity of this technique relies on an accurate determination of the initial monomer-to-internal standard ratio, A[subscript 0], because all subsequent calculations of…
Potency Determination of Antidandruff Shampoos in Nystatin International Unit Equivalents
Anusha Hewage, D. B. G.; Pathirana, W.; Pinnawela, Amara
2008-01-01
A convenient standard microbiological potency determination test for the antidandruff shampoos was developed by adopting the pharmacopoeial microbiological assay procedure of the drug nystatin. A standard curve was drawn consisting of the inhibition zone diameters vs. logarithm of nystatin concentrations in international units using the fungus Saccharomyces cerevisiae (yeast) strain National Collection of Type Culture (NCTC) 1071606 as the test organism. From the standard curve the yeast inhibitory potencies of the shampoos in nystatin international unit equivalents were determined from the respective inhibition zones of the test samples of the shampoos. Under test conditions four shampoo samples showed remarkable fungal inhibitory potencies of 10227, 10731, 12396 and 18211 nystatin international unit equivalents/ml while two shampoo samples had extremely feeble inhibitory potencies 4.07 and 4.37 nystatin international unit equivalents/ml although the latter two products claimed antifungal activity. The potency determination method could be applied to any antidandruff shampoo with any one or a combination of active ingredients. PMID:21394271
Calmet, D; Ameon, R; Bombard, A; Brun, S; Byrde, F; Chen, J; Duda, J-M; Forte, M; Fournier, M; Fronka, A; Haug, T; Herranz, M; Husain, A; Jerome, S; Jiranek, M; Judge, S; Kim, S B; Kwakman, P; Loyen, J; LLaurado, M; Michel, R; Porterfield, D; Ratsirahonana, A; Richards, A; Rovenska, K; Sanada, T; Schuler, C; Thomas, L; Tokonami, S; Tsapalov, A; Yamada, T
2017-04-01
Radiological protection is a matter of concern for members of the public and thus national authorities are more likely to trust the quality of radioactivity data provided by accredited laboratories using common standards. Normative approach based on international standards aims to ensure the accuracy or validity of the test result through calibrations and measurements traceable to the International System of Units. This approach guarantees that radioactivity test results on the same types of samples are comparable over time and space as well as between different testing laboratories. Today, testing laboratories involved in radioactivity measurement have a set of more than 150 international standards to help them perform their work. Most of them are published by the International Standardization Organization (ISO) and the International Electrotechnical Commission (IEC). This paper reviews the most essential ISO standards that give guidance to testing laboratories at different stages from sampling planning to the transmission of the test report to their customers, summarizes recent activities and achievements and present the perspectives on new standards under development by the ISO Working Groups dealing with radioactivity measurement in connection with radiological protection. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Evaluation of minerals content of drinking water in Malaysia.
Azlan, Azrina; Khoo, Hock Eng; Idris, Mohd Aizat; Ismail, Amin; Razman, Muhammad Rizal
2012-01-01
The drinking and mineral water samples obtained from different geographical locations had concentrations of the selected minerals lower than the standard limits, except for manganese, arsenic, and fluoride. The concentrations of manganese and arsenic in two mineral water samples were slightly higher than the standard international recommended limits. One mineral water sample had a fluoride concentration higher than the standard limits, whereas manganese was not detected in nine drinking and mineral water samples. Most of the selected minerals found in the tap water samples were below the international standard limits, except for iron and manganese. The concentrations of iron and manganese in the tap water samples were higher than the standard limits, which were obtained from one and three of the studied locations, respectively. The potable water obtained from various manufacturers and locations in Peninsular Malaysia is safe for consumption, as the minerals concentrations were below the standard limits prescribed by the Malaysian Food Regulations of 1985. The data obtained may also provide important information related to daily intake of these minerals from drinking water.
Evaluation of Minerals Content of Drinking Water in Malaysia
Azlan, Azrina; Khoo, Hock Eng; Idris, Mohd Aizat; Ismail, Amin; Razman, Muhammad Rizal
2012-01-01
The drinking and mineral water samples obtained from different geographical locations had concentrations of the selected minerals lower than the standard limits, except for manganese, arsenic, and fluoride. The concentrations of manganese and arsenic in two mineral water samples were slightly higher than the standard international recommended limits. One mineral water sample had a fluoride concentration higher than the standard limits, whereas manganese was not detected in nine drinking and mineral water samples. Most of the selected minerals found in the tap water samples were below the international standard limits, except for iron and manganese. The concentrations of iron and manganese in the tap water samples were higher than the standard limits, which were obtained from one and three of the studied locations, respectively. The potable water obtained from various manufacturers and locations in Peninsular Malaysia is safe for consumption, as the minerals concentrations were below the standard limits prescribed by the Malaysian Food Regulations of 1985. The data obtained may also provide important information related to daily intake of these minerals from drinking water. PMID:22649292
Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki
2017-01-01
We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum-group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.
Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki
2010-09-15
Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.
The Third International Standard for Corticotrophin
Bangham, D. R.; Mussett, M. V.; Stack-Dunne, M. P.
1962-01-01
At its meeting in September 1957, the WHO Expert Committee on Biological Standardization agreed with the recommendation of the International Conference on Corticotrophin, held in July 1957, that a new international standard for corticotrophin should be set up, since the Second International Standard was made from crude material and was unsuitable for the assay of the purer preparations of corticotrophin now in general clinical use. In this paper, the authors describe the steps taken to establish the Third International Standard for Corticotrophin, from the preparation and international collaborative assay of the new material to the choice of the ”subcutaneous assay” for deriving the potency. The clinical and pharmacological implications of this choice are discussed. Since the preparation, characterization and exact quantitative assay of standards for corticotrophin are so difficult, several batches of approximately 3500 ampoules were prepared in a similar way from the same material to serve as an international Working Standard. Samples from two batches were included in the collaborative assay and found to have the same potency as the Third Standard. Sufficient ampoules of the Working Standard are available for use as national and laboratory standards. PMID:13966359
Commercial versus Internally Developed Standardized Tests: Lessons from a Small Regional School
ERIC Educational Resources Information Center
Hadjicharalambous, Costas
2014-01-01
The author compares the efficacy of commercially available and internally developed standardized tests and evaluates their strengths and weakness in assessing student learning outcomes. The author shares the experience of a regional school in developing a standardized test to assess business knowledge. Data from a sample of 268 students were used…
Kim, Ki-Hyun; Anthwal, A; Pandey, Sudhir Kumar; Kabir, Ehsanul; Sohn, Jong Ryeul
2010-11-01
In this study, a series of GC calibration experiments were conducted to examine the feasibility of the thermal desorption approach for the quantification of five carbonyl compounds (acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) in conjunction with two internal standard compounds. The gaseous working standards of carbonyls were calibrated with the aid of thermal desorption as a function of standard concentration and of loading volume. The detection properties were then compared against two types of external calibration data sets derived by fixed standard volume and fixed standard concentration approach. According to this comparison, the fixed standard volume-based calibration of carbonyls should be more sensitive and reliable than its fixed standard concentration counterpart. Moreover, the use of internal standard can improve the analytical reliability of aromatics and some carbonyls to a considerable extent. Our preliminary test on real samples, however, indicates that the performance of internal calibration, when tested using samples of varying dilution ranges, can be moderately different from that derivable from standard gases. It thus suggests that the reliability of calibration approaches should be examined carefully with the considerations on the interactive relationships between the compound-specific properties and the operation conditions of the instrumental setups.
Housekeeping genes as internal standards: use and limits.
Thellin, O; Zorzi, W; Lakaye, B; De Borman, B; Coumans, B; Hennen, G; Grisar, T; Igout, A; Heinen, E
1999-10-08
Quantitative studies are commonly realised in the biomedical research to compare RNA expression in different experimental or clinical conditions. These quantifications are performed through their comparison to the expression of the housekeeping gene transcripts like glyceraldehyde-3-phosphate dehydrogenase (G3PDH), albumin, actins, tubulins, cyclophilin, hypoxantine phsophoribosyltransferase (HRPT), L32. 28S, and 18S rRNAs are also used as internal standards. In this paper, it is recalled that the commonly used internal standards can quantitatively vary in response to various factors. Possible variations are illustrated using three experimental examples. Preferred types of internal standards are then proposed for each of these samples and thereafter the general procedure concerning the choice of an internal standard and the way to manage its uses are discussed.
Distribution of the two-sample t-test statistic following blinded sample size re-estimation.
Lu, Kaifeng
2016-05-01
We consider the blinded sample size re-estimation based on the simple one-sample variance estimator at an interim analysis. We characterize the exact distribution of the standard two-sample t-test statistic at the final analysis. We describe a simulation algorithm for the evaluation of the probability of rejecting the null hypothesis at given treatment effect. We compare the blinded sample size re-estimation method with two unblinded methods with respect to the empirical type I error, the empirical power, and the empirical distribution of the standard deviation estimator and final sample size. We characterize the type I error inflation across the range of standardized non-inferiority margin for non-inferiority trials, and derive the adjusted significance level to ensure type I error control for given sample size of the internal pilot study. We show that the adjusted significance level increases as the sample size of the internal pilot study increases. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Flash Point Performance Evaluation
2014-03-01
ACRONYMS AND ABBREVIATIONS Acronym Definition ASTM ASTM International, consensus standards and specifications B20 Biodiesel containing 20% FAME...HRJ-1 is a sample of HEFA SPK [10] that is used to blend semi-synthetic jet fuel. The B20-1 is a sample of a 20% biodiesel blend [20]. The US Army...Standard Specification for Diesel Fuel Oil, Biodiesel Blend (B6 to B20), ASTM International, W. Conshohocken, PA 21. MIL-DTL-25576E the Detail
EVALUATION OF ANALYTICAL REPORTING ERRORS GENERATED AS DESCRIBED IN SW-846 METHOD 8261A
SW-846 Method 8261A incorporates the vacuum distillation of analytes from samples, and their recoveries are characterized by internal standards. The internal standards measure recoveries with confidence intervals as functions of physical properties. The frequency the calculate...
Golay, Pierre-Alain; Moulin, Julie
2016-01-01
A collaborative study was conducted on AOAC First Action Method 2012.13 "Determination of Labeled Fatty Acids Content in Milk Products and Infant Formula by Capillary Gas Chromatography," which is based on an initial International Organization for Standardization (ISO)-International Dairy Federation (IDF) New Work Item that has been moved forward to ISO 16958:2015|IDF 231:2015 in November 2015. It was decided to merge the two activities after the agreement signed between ISO and AOAC in June 2012 to develop common standards and to avoid duplicate work. The collaborative study was performed after having provided highly satisfactory single-laboratory validation results [Golay, P.A., & Dong, Y. (2015) J. AOAC Int. 98, 1679-1696] that exceeded the performance criteria defined in AOAC Standard Method Performance Requirement (SMPR(®)) 2012.011 (September 29, 2012) on 12 products selected by the AOAC Stakeholder Panel on Infant Formula (SPIFAN). After a qualification period of 1 month, 18 laboratories participated in the fatty acids analysis of 12 different samples in duplicate. Six samples were selected to meet AOAC SPIFAN requirements (i.e., infant formula and adult nutritionals in powder and liquid formats), and the other Six samples were selected to meet ISO-IDF requirements (i.e., dairy products such as milk powder, liquid milk, cream, butter, infant formula with milk, and cheese). The fatty acids were analyzed directly in all samples without preliminary fat extraction, except in one sample (cheese). Powdered samples were analyzed after dissolution (i.e., reconstitution) in water, whereas liquid samples (or extracted fat) were analyzed directly. After addition of the internal standards solution [C11:0 fatty acid methyl ester (FAME) and C13:0 triacylglycerols (TAG)] to the samples, fatty acids attached to lipids were transformed into FAMEs by direct transesterification using methanolic sodium methoxide. FAMEs were separated using highly polar capillary GLC and were identified by comparison with the retention times of pure analytical standards. Quantification of fatty acids was done relative to C11:0 FAME as internal standard and to instrument response factors (determined separately using calibration standards mixture). The performance of the method (i.e., transesterification) was monitored in all samples using the second internal standard, C13:0 TAG. RSDR values were summarized separately for labeled fatty acids in SPIFAN materials and ISO-IDF materials due to different expression of results. This method was applied to representative dairy, infant formula, and adult/pediatric nutritional products and demonstrated global acceptable reproducibility precision for all fatty acids analyzed (i.e., 46 individuals and/or groups) for these categories of products.
Eberl, D.D.
2003-01-01
RockJock is a computer program that determines quantitative mineralogy in powdered samples by comparing the integrated X-ray diffraction (XRD) intensities of individual minerals in complex mixtures to the intensities of an internal standard. Analysis without an internal standard (standardless analysis) also is an option. This manual discusses how to prepare and X-ray samples and mineral standards for these types of analyses and describes the operation of the program. Carefully weighed samples containing an internal standard (zincite) are ground in a McCrone mill. Randomly oriented preparations then are X-rayed, and the X-ray data are entered into the RockJock program. Minerals likely to be present in the sample are chosen from a list of standards, and the calculation is begun. The program then automatically fits the sum of stored XRD patterns of pure standard minerals (the calculated pattern) to the measured pattern by varying the fraction of each mineral standard pattern, using the Solver function in Microsoft Excel to minimize a degree of fit parameter between the calculated and measured pattern. The calculation analyzes the pattern (usually 20 to 65 degrees two-theta) to find integrated intensities for the minerals. Integrated intensities for each mineral then are determined from the proportion of each mineral standard pattern required to give the best fit. These integrated intensities then are compared to the integrated intensity of the internal standard, and the weight percentages of the minerals are calculated. The results are presented as a list of minerals with their corresponding weight percent. To some extent, the quality of the analysis can be checked because each mineral is analyzed independently, and, therefore, the sum of the analysis should approach 100 percent. Also, the method has been shown to give good results with artificial mixtures. The program is easy to use, but does require an understanding of mineralogy, of X-ray diffraction practice, and an elementary knowledge of the Excel program.
Yoon, Donhee; Lee, Dongkun; Lee, Jong-Hyeon; Cha, Sangwon; Oh, Han Bin
2015-01-30
Quantifying polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) with a conventional crystalline matrix generally suffers from poor sample-to-sample or shot-to-shot reproducibility. An ionic-liquid matrix has been demonstrated to mitigate these reproducibility issues by providing a homogeneous sample surface, which is useful for quantifying polymers. In the present study, we evaluated the use of an ionic liquid matrix, i.e., 1-methylimidazolium α-cyano-4-hydroxycinnamate (1-MeIm-CHCA), to quantify polyhexamethylene guanidine (PHMG) samples that impose a critical health hazard when inhaled in the form of droplets. MALDI-TOF mass spectra were acquired for PHMG oligomers using a variety of ionic-liquid matrices including 1-MeIm-CHCA. Calibration curves were constructed by plotting the sum of the PHMG oligomer peak areas versus PHMG sample concentration with a variety of peptide internal standards. Compared with the conventional crystalline matrix, the 1-MeIm-CHCA ionic-liquid matrix had much better reproducibility (lower standard deviations). Furthermore, by using an internal peptide standard, good linear calibration plots could be obtained over a range of PMHG concentrations of at least 4 orders of magnitude. This study successfully demonstrated that PHMG samples can be quantitatively characterized by MALDI-TOFMS with an ionic-liquid matrix and an internal standard. Copyright © 2014 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Greene, Ben; McClure, Mark B.; Baker, David L.
2006-01-01
This work presents an overview of the International Organization for Standardization (ISO) 15859 International Standard for Space Systems Fluid Characteristics, Sampling and Test Methods Parts 1 through 13 issued in June 2004. These standards establish requirements for fluid characteristics, sampling, and test methods for 13 fluids of concern to the propellant community and propellant characterization laboratories: oxygen, hydrogen, nitrogen, helium, nitrogen tetroxide, monomethylhydrazine, hydrazine, kerosene, argon, water, ammonia, carbon dioxide, and breathing air. A comparison of the fluid characteristics, sampling, and test methods required by the ISO standards to the current military and NASA specifications, which are in use at NASA facilities and elsewhere, is presented. Many ISO standards composition limits and other content agree with those found in the applicable parts of NASA SE-S-0073, NASA SSP 30573, military performance standards and details, and Compressed Gas Association (CGA) commodity specifications. The status of a current project managed at NASA Johnson Space Center White Sands Test Facility (WSTF) to rewrite these documents is discussed.
Hewavitharana, Amitha K; Abu Kassim, Nur Sofiah; Shaw, Paul Nicholas
2018-06-08
With mass spectrometric detection in liquid chromatography, co-eluting impurities affect the analyte response due to ion suppression/enhancement. Internal standard calibration method, using co-eluting stable isotope labelled analogue of each analyte as the internal standard, is the most appropriate technique available to correct for these matrix effects. However, this technique is not without drawbacks, proved to be expensive because separate internal standard for each analyte is required, and the labelled compounds are expensive or require synthesising. Traditionally, standard addition method has been used to overcome the matrix effects in atomic spectroscopy and was a well-established method. This paper proposes the same for mass spectrometric detection, and demonstrates that the results are comparable to those with the internal standard method using labelled analogues, for vitamin D assay. As conventional standard addition procedure does not address procedural errors, we propose the inclusion of an additional internal standard (not co-eluting). Recoveries determined on human serum samples show that the proposed method of standard addition yields more accurate results than the internal standardisation using stable isotope labelled analogues. The precision of the proposed method of standard addition is superior to the conventional standard addition method. Copyright © 2018 Elsevier B.V. All rights reserved.
Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh
2007-02-01
A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.
Preparation and application of in-fibre internal standardization solid-phase microextraction.
Zhao, Wennan; Ouyang, Gangfeng; Pawliszyn, Janusz
2007-03-01
The in-fibre standardization method is a novel approach that has been developed for field sampling/sample preparation, in which an internal standard is pre-loaded onto a solid-phase microextraction (SPME) fibre for calibration of the extraction of target analytes in field samples. The same method can also be used for in-vial sample analysis. In this study, different techniques to load the standard to a non-porous SPME fibre were investigated. It was found that the appropriateness of the technique depends on the physical properties of the standards that are used for the analysis. Headspace extraction of the standard dissolved in pumping oil works well for volatile compounds. Conversely, headspace extraction of the pure standard is an effective approach for semi-volatile compounds. For compounds with low volatility, a syringe-fibre transfer method and direct extraction of the standard dissolved in a solvent exhibited a good reproducibility (<5% RSD). The main advantage of the approaches investigated in this study is that the standard generation vials can be reused for hundreds of analyses without exhibiting significant loss. Moreover, most of the standard loading processes studied can be performed automatically, which is efficient and precise. Finally, the standard loading technique and in-fibre standardization method were applied to a complex matrix (milk) and the results illustrated that the matrix effect can be effectively compensated for with this approach.
Third International Standard for Posterior Pituitary
Bangham, D. R.; Mussett, Marjorie V.
1958-01-01
In October 1955, stocks of the Second International Standard for Posterior Pituitary were running low and the Department of Biological Standards of the National Institute for Medical Research, London, was asked to proceed with the arrangements for an international collaborative assay of material for the Third Standard. A single 142-g batch of posterior-pituitary-lobe powder was obtained and distributed in ampoules, in approximately 30-mg quantities. Samples were sent to 19 laboratories in 10 countries. In all, 185 assays were carried out, 122 for oxytocic activity, 53 for vasopressor activity and 10 for antidiuretic activity. On the basis of the results, which were analysed statistically at the National Institute for Medical Research, it was agreed that the potency of the Third Standard (re-named International Standard for Oxytocic, Vasopressor and Antidiuretic Substances in 1956, in view of the recent synthesis of oxytocin and vasopressin) should be expressed as 2.0 International Units per milligram. The International Unit therefore remains unchanged as 0.5 mg of the dry powder. PMID:13585079
O. Musaiger, Abdulrahman; Al-Mannai, Mariam; Tayyem, Reema
2013-01-01
Objective: To find out the prevalence of overweight and obesity among female adolescents in Jordan. Methodology: A cross-sectional survey on females aged 15–18 in Amman, Jordan, was carried out using a multistage stratified random sampling method. The total sample size was 475 girls. Weight and height were measured and body mass index for age was used to determine overweight and obesity using the IOTF and WHO international standards. Results: The prevalence of overweight and obesity decreased with age. The highest prevalence of overweight and obesity was reported at age 15 (24.4% and 8.9%, respectively). The WHO standard showed a higher prevalence of obesity than the IOTF standard in all age groups. Conclusions: Overweight and obesity are serious public health problems among adolescents in Jordan, using both international standards. A program to combat obesity among schoolchildren, therefore, should be given a high priority in school health policy in Jordan. PMID:24353605
Harper, Martin; Ashley, Kevin
2013-01-01
Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, interlaboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements. PMID:23548078
Grate, Jay W; Gonzalez, Jhanis J; O'Hara, Matthew J; Kellogg, Cynthia M; Morrison, Samuel S; Koppenaal, David W; Chan, George C-Y; Mao, Xianglei; Zorba, Vassilia; Russo, Richard E
2017-09-08
Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standards.
Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia
2016-06-01
Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Method for measuring recovery of catalytic elements from fuel cells
Shore, Lawrence [Edison, NJ; Matlin, Ramail [Berkeley, NJ
2011-03-08
A method is provided for measuring the concentration of a catalytic clement in a fuel cell powder. The method includes depositing on a porous substrate at least one layer of a powder mixture comprising the fuel cell powder and an internal standard material, ablating a sample of the powder mixture using a laser, and vaporizing the sample using an inductively coupled plasma. A normalized concentration of catalytic element in the sample is determined by quantifying the intensity of a first signal correlated to the amount of catalytic element in the sample, quantifying the intensity of a second signal correlated to the amount of internal standard material in the sample, and using a ratio of the first signal intensity to the second signal intensity to cancel out the effects of sample size.
de Gois, Jefferson S; Vallelonga, Paul; Spolaor, Andrea; Devulder, Veerle; Borges, Daniel L G; Vanhaecke, Frank
2016-01-01
A simple and accurate methodology for Br isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) with pneumatic nebulization for sample introduction was developed. The Br(+) signals could be measured interference-free at high mass resolution. Memory effects for Br were counteracted using 5 mmol L(-1) of NH4OH in sample, standard, and wash solutions. The major cation load of seawater was removed via cation exchange chromatography using Dowex 50WX8 resin. Subsequent Br preconcentration was accomplished via evaporation of the sample solution at 90 °C, which did not induce Br losses or isotope fractionation. Mass discrimination was corrected for by external correction using a Cl-matched standard measured in a sample-standard bracketing approach, although Sr, Ge, and Se were also tested as potential internal standards for internal correction for mass discrimination. The δ(81)Br (versus standard mean ocean bromide (SMOB)) values thus obtained for the NaBr isotopic reference material NIST SRM 977 and for IRMM BCR-403 seawater certified reference material are in agreement with literature values. For NIST SRM 977, the (81)Br/(79)Br ratio (0.97291) was determined with a precision ≤0.08‰ relative standard deviation (RSD).
ERIC Educational Resources Information Center
Al-Oweidi, Alia
2015-01-01
The purpose of the study is to evaluate the vocational rehabilitation services provided to people with disabilities according to international standards in Jordan. The sample of the study consisted of (56) managers and teachers in four specialized centers in vocational rehabilitation. The findings showed that the compatibility degree ranged…
Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.
Benedict, Ralph H B; Amato, Maria Pia; Boringa, Jan; Brochet, Bruno; Foley, Fred; Fredrikson, Stan; Hamalainen, Paivi; Hartung, Hans; Krupp, Lauren; Penner, Iris; Reder, Anthony T; Langdon, Dawn
2012-07-16
An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different languages and countries were discussed. Five steps to achieve optimal psychometric validation were proposed. In Step 1, test stimuli should be standardized for the target culture or language under consideration. In Step 2, examiner instructions must be standardized and translated, including all information from manuals necessary for administration and interpretation. In Step 3, samples of at least 65 healthy persons should be studied for normalization, matched to patients on demographics such as age, gender and education. The objective of Step 4 is test-retest reliability, which can be investigated in a small sample of MS and/or healthy volunteers over 1-3 weeks. Finally, in Step 5, criterion validity should be established by comparing MS and healthy controls. At this time, preliminary studies are underway in a number of countries as we move forward with this international assessment tool for cognition in MS.
Figures of Merit for Lunar Simulants
NASA Technical Reports Server (NTRS)
Slane, Frederick A.; Rickman, Douglas L.
2012-01-01
At an earlier SRR the concept for an international standard on Lunar regolith simulants was presented. The international standard, ISO 10788, Lunar Simulants, has recently been published. This paper presents the final content of the standard. Therefore, we are presenting an update of the following: The collection and analysis of lunar samples from 1969 to present has yielded large amounts of data. Published analyses give some idea of the complex nature of the regolith at all scales, rocks, soils and the smaller particulates commonly referred to as dust. Data recently acquired in support of NASA s simulant effort has markedly increased our knowledge and quantitatively demonstrates that complexity. It is anticipated that future analyses will further add to the known complexity. In an effort to communicate among the diverse technical communities performing research on or research using regolith samples and simulants, a set of Figures of Merit (FoM) have been devised. The objective is to allow consistent and concise comparative communication between researchers from multiple organizations and nations engaged in lunar exploration. This paper describes Figures of Merit in a new international standard for Lunar Simulants. The FoM methodology uses scientific understanding of the lunar samples to formulate parameters which are reproducibly quantifiable. Contaminants and impurities in the samples are also addressed.
Klimek-Turek, A; Sikora, M; Rybicki, M; Dzido, T H
2016-03-04
A new concept of using thin-layer chromatography to sample preparation for the quantitative determination of solute/s followed by instrumental techniques is presented Thin-layer chromatography (TLC) is used to completely separate acetaminophen and its internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position (after the final stage of the thin-layer chromatogram development). The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. The exctraction procedure of the solute/s and internal standard can proceed from whole solute frontal zone or its part without lowering in accuracy of quantitative analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Cole, T J
2006-12-01
This article discusses statistical considerations for the design of a new study intended to provide an International Growth Standard for Preadolescent and Adolescent Children, including issues such as cross-sectional, longitudinal, and mixed designs; sample-size derivation for the number of populations and number of children per population; modeling of growth centiles of height, weight, and other measurements; and modeling of the adolescent growth spurt. The conclusions are that a mixed longitudinal design will provide information on both growth distance and velocity; samples of children from 5 to 10 sites should be suitable for an international standard (based on political rather than statistical arguments); the samples should be broadly uniform across age but oversampled during puberty, and should include data into adulthood. The LMS method is recommended for constructing measurement centiles, and parametric or semiparametric approaches are available to estimate the timing of the adolescent growth spurt in individuals. If the new standard is to be grafted onto the 2006 World Health Organization (WHO) reference, caution is needed at the join point of 5 years, where children from the new standard are likely to be appreciably more obese than those from the WHO reference, due to the rising trends in obesity and the time gap in data collection between the two surveys.
Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L
2009-12-01
A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0.5, and 10 microg Be/filter, respectively. Overall recoveries were 93.2%, 102%, and 80.6% for the low, medium, and high beryllium loadings, respectively. Expanded uncertainty estimates for interlaboratory analysis of low, medium, and high beryllium loadings, calculated in accordance with ASTM D7440, were 18.8%, 19.8%, and 24.4%, respectively. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method, ASTM D7439.
Moraleja, Irene; Esteban-Fernández, Diego; Lázaro, Alberto; Humanes, Blanca; Neumann, Boris; Tejedor, Alberto; Luz Mena, M; Jakubowski, Norbert; Gómez-Gómez, M Milagros
2016-03-01
The study of the distribution of the cytostatic drugs cisplatin, carboplatin, and oxaliplatin along the kidney may help to understand their different nephrotoxic behavior. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) allows the acquisition of trace element images in biological tissues. However, results obtained are affected by several variations concerning the sample matrix and instrumental drifts. In this work, an internal standardization method based on printing an Ir-spiked ink onto the surface of the sample has been developed to evaluate the different distributions and accumulation levels of the aforementioned drugs along the kidney of a rat model. A conventional ink-jet printer was used to print fresh sagittal kidney tissue slices of 4 μm. A reproducible and homogenous deposition of the ink along the tissue was observed. The ink was partially absorbed on top of the tissue. Thus, this approach provides a pseudo-internal standardization, due to the fact that the ablation sample and internal standard take place subsequently and not simultaneously. A satisfactory normalization of LA-ICP-MS bioimages and therefore a reliable comparison of the kidney treated with different Pt-based drugs were achieved even for tissues analyzed on different days. Due to the complete ablation of the sample, the transport of the ablated internal standard and tissue to the inductively coupled plasma-mass spectrometry (ICP-MS) is practically taking place at the same time. Pt accumulation in the kidney was observed in accordance to the dosages administered for each drug. Although the accumulation rate of cisplatin and oxaliplatin is high in both cases, their Pt distributions differ. The strong nephrotoxicity observed for cisplatin and the absence of such side effect in the case of oxaliplatin could explain these distribution differences. The homogeneous distribution of oxaliplatin in the cortical and medullar areas could be related with its higher affinity for cellular transporters such as MATE2-k.
Furlong, Michael; Bessire, Andrew; Song, Wei; Huntington, Christopher; Groeber, Elizabeth
2010-07-15
During routine liquid chromatography/tandem mass spectrometric (LC/MS/MS) bioanalysis of a small molecule analyte in rat serum samples from a toxicokinetic study, an unexpected interfering peak was observed in the extracted ion chromatogram of the internal standard. No interfering peaks were observed in the extracted ion chromatogram of the analyte. The dose-dependent peak area response and peak area response versus time profiles of the interfering peak suggested that it might have been related to a metabolite of the dosed compound. Further investigation using high-resolution mass spectrometry led to unequivocal identification of the interfering peak as an N-desmethyl metabolite of the parent analyte. High-resolution mass spectrometry (HRMS) was also used to demonstrate that the interfering response of the metabolite in the multiple reaction monitoring (MRM) channel of the internal standard was due to an isobaric relationship between the (13)C-isotope of the metabolite and the internal standard (i.e., common precursor ion mass), coupled with a metabolite product ion with identical mass to the product ion used in the MRM transition of the internal standard. These results emphasize (1) the need to carefully evaluate internal standard candidates with regard to potential interferences from metabolites during LC/MS/MS method development, validation and bioanalysis of small molecule analytes in biological matrices; (2) the value of HRMS as a tool to investigate unexpected interferences encountered during LC/MS/MS analysis of small molecules in biological matrices; and (3) the potential for interference regardless of choice of IS and therefore the importance of conducting assay robustness on incurred in vitro or in vivo study samples. Copyright 2010 John Wiley & Sons, Ltd.
Standard-less analysis of Zircaloy clad samples by an instrumental neutron activation method
NASA Astrophysics Data System (ADS)
Acharya, R.; Nair, A. G. C.; Reddy, A. V. R.; Goswami, A.
2004-03-01
A non-destructive method for analysis of irregular shape and size samples of Zircaloy has been developed using the recently standardized k0-based internal mono standard instrumental neutron activation analysis (INAA). The samples of Zircaloy-2 and -4 tubes, used as fuel cladding in Indian boiling water reactors (BWR) and pressurized heavy water reactors (PHWR), respectively, have been analyzed. Samples weighing in the range of a few tens of grams were irradiated in the thermal column of Apsara reactor to minimize neutron flux perturbations and high radiation dose. The method utilizes in situ relative detection efficiency using the γ-rays of selected activation products in the sample for overcoming γ-ray self-attenuation. Since the major and minor constituents (Zr, Sn, Fe, Cr and/or Ni) in these samples were amenable to NAA, the absolute concentrations of all the elements were determined using mass balance instead of using the concentration of the internal mono standard. Concentrations were also determined in a smaller size Zircaloy-4 sample by irradiating in the core position of the reactor to validate the present methodology. The results were compared with literature specifications and were found to be satisfactory. Values of sensitivities and detection limits have been evaluated for the elements analyzed.
The International Standard for Oxytetracycline
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1955-01-01
The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard. Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg. PMID:13284563
Adler, I.; Axelrod, J.M.
1955-01-01
The use of internal standards in the analysis of ores and minerals of widely-varying matrix by means of fluorescent X-ray spectroscopy is frequently the most practical approach. Internal standards correct for absorption and enhancement effects except when an absorption edge falls between the comparison lines or a very strong emission line falls between the absorption edges responsible for the comparison lines. Particle size variations may introduce substantial errors. One method of coping with the particle size problem is grinding the sample with an added abrasive. ?? 1955.
Determination of patulin in apple juice by liquid chromatography: collaborative study.
Brause, A R; Trucksess, M W; Thomas, F S; Page, S W
1996-01-01
An AOAC International-International Union of Pure and Applied Chemistry-International Fruit Juice Union (AOAC-IUPAC-IFJU) collaborative study was conducted to evaluate a liquid chromatographic (LC) procedure for determination of patulin in apple juice. Patulin is a mold metabolite found naturally in rotting apples. Patulin is extracted with ethyl acetate, treated with sodium carbonate solution, and determined by reversed-phase LC with UV detection at 254 or 276 nm. Water, water-tetrahydrofuran, or water-acetonitrile was used as mobile phase. Levels determined in spiked test samples were 20, 50, 100, and 200 micrograms/L. A test sample naturally contaminated at 31 micrograms/L was also included. Twenty-two collaborators in 10 countries analyzed 12 test samples of apple juice. Recoveries averaged 96%, with a range of 91-108%. Repeatability relative standard deviations (RSDr) ranged from 10.9 to 53.8%. The reproducibility relative standard deviation (RSDR) ranged from 15.1 to 68.8%. The LC method for determination of patulin in apple juice has been adopted first action by AOAC INTERNATIONAL.
Discrepancy Score Reliabilities in the WAIS-IV Standardization Sample
ERIC Educational Resources Information Center
Glass, Laura A.; Ryan, Joseph J.; Charter, Richard A.
2010-01-01
In the present investigation, the authors provide internal consistency reliabilities for Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV) subtest and Index discrepancy scores using the standardization sample as the data source. Reliabilities ranged from 0.55 to 0.88 for subtest discrepancy scores and 0.80 to 0.91 for Index discrepancy…
Thorn, Kevin A.; Folan, Daniel W.; MacCarthy, Patrick
1989-01-01
Standard and reference samples of the International Humic Substances Society have been characterized by solution state carbon-13 and hydrogen-1 nuclear magnetic resonance (NMR) spectrometry. Samples included the Suwannee River, soil, and peat standard fulvic and humic acids, the Leonardite standard humic acid, the Nordic aquatic reference fulvic and humic acids, and the Summit Hill soil reference humic acid. Aqueous-solution carbon-13 NMR analyses included the measurement of spin-lattice relaxation times, measurement of nuclear Overhauser enhancement factors, measurement of quantitative carbon distributions, recording of attached proton test spectra, and recording of spectra under nonquantitative conditions. Distortionless enhancement by polarization transfer carbon-13 NMR spectra also were recorded on the Suwannee River fulvic acid in deuterated dimethyl sulfoxide. Hydrogen-1 NMR spectra were recorded on sodium salts of the samples in deuterium oxide. The carbon aromaticities of the samples ranged from 0.24 for the Suwannee River fulvic acid to 0.58 for the Leonardite humic acid.
[Sampling methods for PM2.5 from stationary sources: a review].
Jiang, Jing-Kun; Deng, Jian-Guo; Li, Zhen; Li, Xing-Hua; Duan, Lei; Hao, Ji-Ming
2014-05-01
The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.
Tsai, I-Lin; Kuo, Ching-Hua; Sun, Hsin-Yun; Chuang, Yu-Chung; Chepyala, Divyabharathi; Lin, Shu-Wen; Tsai, Yun-Jung
2017-10-25
Outbreaks of multidrug-resistant Gram-negative bacterial infections have been reported worldwide. Colistin, an antibiotic with known nephrotoxicity and neurotoxicity, is now being used to treat multidrug-resistant Gram-negative strains. In this study, we applied an on-spot internal standard addition approach coupled with an ultra high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify colistin A and B from dried blood spots (DBSs). Only 15μL of whole blood was required for each sample. An internal standard with the same yield of extraction recoveries as colistin was added to the spot before sample extraction for accurate quantification. Formic acid in water (0.15%) with an equal volume of acetonitrile (50:50v/v) was used as the extraction solution. With the optimized extraction process and LC-MS/MS conditions, colistin A and B could be quantified from a DBS with respective limits of quantification of 0.13 and 0.27μgmL -1 , and the retention times were < 2min. The relative standard deviations of within-run and between-run precisions for peak area ratios were all < 17.3%. Accuracies were 91.5-111.2% for lower limit of quantification, low, medium, and high QC samples. The stability of the easily hydrolyzed prodrug, colistin methanesulfonate, was investigated in DBSs. Less than 4% of the prodrug was found to be hydrolyzed in DBSs at room temperature after 48h. The developed method applied an on-spot internal standard addition approach which benefited the precision and accuracy. Results showed that DBS sampling coupled with the sensitive LC-MS/MS method has the potential to be an alternative approach for colistin quantification, where the bias of prodrug hydrolysis in liquid samples is decreased. Copyright © 2017 Elsevier B.V. All rights reserved.
Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E
2018-01-16
The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fritz, Brad G.; Barnett, J. M.
2015-11-01
Clause 6.4.4 in the American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1 standard, Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities, addresses the internal smoothness of sample transport lines present between the nozzle and the analyzer (or collector). This paper evaluates the appropriateness of this clause by comparing roughness length of various materials against the required relative roughness, and by conducting computational fluid dynamic modeling. The results indicate that the inclusion of numerical criteria for the relative roughness of pipe by the ANSI Standard N13.1 (Section 6.4.4) is not appropriate.more » Recommended alternatives would be elimination of the numerical criteria, or modification of the standard to include a variable criteria for relative roughness.« less
Valid internal standard technique for arson detection based on gas chromatography-mass spectrometry.
Salgueiro, Pedro A S; Borges, Carlos M F; Bettencourt da Silva, Ricardo J N
2012-09-28
The most popular procedures for the detection of residues of accelerants in fire debris are the ones published by the American Society for Testing and Materials (ASTM E1412-07 and E1618-10). The most critical stages of these tests are the conservation of fire debris from the sampling to the laboratory, the extraction of residues of accelerants from the debris to the activated charcoal strips (ACS) and from those to the final solvent, as well as the analysis of sample extract by gas chromatography-mass spectrometry (GC-MS) and the interpretation of the instrumental signal. This work proposes a strategy for checking the quality of the sample conservation, the accelerant residues transference to final solvent and GC-MS analysis, using internal standard additions. It is used internal standards ranging from a highly volatile compound for checking debris conservation to low volatile compound for checking GC-MS repeatability. The developed quality control (QC) parameters are not affected by GC-MS sensitivity variation and, specifically, the GC-MS performance control is not affected by ACS adsorption saturation that may mask test performance deviations. The proposed QC procedure proved to be adequate to check GC-MS repeatability, ACS extraction and sample conservation since: (1) standard additions are affected by negligible uncertainty and (2) observed dispersion of QC parameters are fit for its intended use. Copyright © 2012 Elsevier B.V. All rights reserved.
Gosselin, Robert C; Adcock, Dorothy M; Bates, Shannon M; Douxfils, Jonathan; Favaloro, Emmanuel J; Gouin-Thibault, Isabelle; Guillermo, Cecilia; Kawai, Yohko; Lindhoff-Last, Edelgard; Kitchen, Steve
2018-03-01
This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH) for providing haemostasis-related guidance documents for clinical laboratories. This inaugural coagulation ICSH document was developed by an ad hoc committee, comprised of international clinical and laboratory direct acting oral anticoagulant (DOAC) experts. The committee developed consensus recommendations for laboratory measurement of DOACs (dabigatran, rivaroxaban, apixaban and edoxaban), which would be germane for laboratories assessing DOAC anticoagulation. This guidance document addresses all phases of laboratory DOAC measurements, including pre-analytical (e.g. preferred time sample collection, preferred sample type, sample stability), analytical (gold standard method, screening and quantifying methods) and post analytical (e.g. reporting units, quality assurance). The committee addressed the use and limitations of screening tests such as prothrombin time, activated partial thromboplastin time as well as viscoelastic measurements of clotting blood and point of care methods. Additionally, the committee provided recommendations for the proper validation or verification of performance of laboratory assays prior to implementation for clinical use, and external quality assurance to provide continuous assessment of testing and reporting method. Schattauer GmbH Stuttgart.
Soyuz 25 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2011-01-01
Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 25. The toxicological assessment of 6 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C-13-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 76, 108 and 88%, respectively. Formaldehyde badges were not returned aboard Soyuz 25.
Feasibility of zero tolerance for Salmonella on raw poultry
USDA-ARS?s Scientific Manuscript database
Ideally, poultry producing countries around the globe should use internationally standardized sampling methods for Salmonella. It is difficult to compare prevalence data from country-to-country when sample plan, sample type, sample frequency and laboratory media along with methods differ. The Europe...
Sleno, Lekha; Volmer, Dietrich A
2006-01-01
Growing interest in the ability to conduct quantitative assays for small molecules by matrix-assisted laser desorption/ionization (MALDI) has been the driving force for several recent studies. This present work includes the investigation of internal standards for these analyses using a high-repetition rate MALDI triple quadrupole instrument. Certain physicochemical properties are assessed for predicting possible matches for internal standards for different small molecules. The importance of similar molecular weight of an internal standard to its analyte is seen through experiments with a series of acylcarnitines, having a fixed charge site and growing alkyl chain length. Both acetyl- and hexanoyl-carnitine were systematically assessed with several other acylcarnitine compounds as internal standards. The results clearly demonstrate that closely matched molecular weights between analyte and internal standard are essential for acceptable quantitation results. Using alpha-cyano-4-hydroxycinnamic acid as the organic matrix, the similarities between analyte and internal standard remain the most important parameter and not necessarily their even distribution within the solid sample spot. Several 4-quinolone antibiotics as well as a diverse group of pharmaceutical drugs were tested as internal standards for the 4-quinolone, ciprofloxacin. Quantitative results were shown using the solution-phase properties, log D and pKa, of these molecules. Their distribution coefficients, log D, are demonstrated as a fundamental parameter for similar crystallization patterns of analyte and internal standard. In the end, it was also possible to quantify ciprofloxacin using a drug from a different compound class, namely quinidine, having a similar log D value as the analyte. Copyright 2006 John Wiley & Sons, Ltd.
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.
O'Connor, Sean; O'Connor, Paula Fey; Feng, H Amy; Ashley, Kevin
2014-10-01
An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material ® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision S r at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝ rt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules.
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules
O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy
2015-01-01
Summary An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision Sr at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝrt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules. PMID:26435581
Soyuz 24 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2011-01-01
Fifteen mini-grab sample containers (m-GSCs) were returned aboard Soyuz. This is the first time all samples were acquired with the mini-grab samplers. The toxicological assessment of 15 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C(13)-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 75, 97 and 79%, respectively. Formaldehyde badges were not returned on Soyuz 24
Ferreira, Vicente; Herrero, Paula; Zapata, Julián; Escudero, Ana
2015-08-14
SPME is extremely sensitive to experimental parameters affecting liquid-gas and gas-solid distribution coefficients. Our aims were to measure the weights of these factors and to design a multivariate strategy based on the addition of a pool of internal standards, to minimize matrix effects. Synthetic but real-like wines containing selected analytes and variable amounts of ethanol, non-volatile constituents and major volatile compounds were prepared following a factorial design. The ANOVA study revealed that even using a strong matrix dilution, matrix effects are important and additive with non-significant interaction effects and that it is the presence of major volatile constituents the most dominant factor. A single internal standard provided a robust calibration for 15 out of 47 analytes. Then, two different multivariate calibration strategies based on Partial Least Square Regression were run in order to build calibration functions based on 13 different internal standards able to cope with matrix effects. The first one is based in the calculation of Multivariate Internal Standards (MIS), linear combinations of the normalized signals of the 13 internal standards, which provide the expected area of a given unit of analyte present in each sample. The second strategy is a direct calibration relating concentration to the 13 relative areas measured in each sample for each analyte. Overall, 47 different compounds can be reliably quantified in a single fully automated method with overall uncertainties better than 15%. Copyright © 2015 Elsevier B.V. All rights reserved.
Reference samples for the earth sciences
Flanagan, F.J.
1974-01-01
A revised list of reference samples of interest to geoscientists has been extended to include samples for the agronomist, the archaeologist and the environmentalist. In addition to the source from which standard samples may be obtained, references or pertinent notes for some samples are included. The number of rock reference samples is now almost adequate, and the variety of ore samples will soon be sufficient. There are very few samples for microprobe work. Oil shales will become more important because of the outlook for world petroleum resources. The dryland equivalent of a submarine basalt might be useful in studies of sea-floor spreading and of the geochemistry of basalts. The Na- and K-feldspars of BCS (British Chemical Standards-Bureau of Analysed Samples), NBS (National Bureau of Standards), and ANRT (Association Kationale de la Recherche Technique) could serve as trace-element standards if such data were available. Similarly, the present NBS flint and plastic clays, as well as their predecessors, might be useful for archaeological pottery studies. The International Decade for Ocean Exploration may stimulate the preparation of ocean-water standards for trace elements or pollutants and a standard for manganese nodules. ?? 1974.
Mirzaian, M; Wisse, P; Ferraz, M J; Marques, A R A; Gaspar, P; Oussoren, S V; Kytidou, K; Codée, J D C; van der Marel, G; Overkleeft, H S; Aerts, J M
2017-03-01
Free sphingoid bases (lysosphingolipids) of primary storage sphingolipids are increased in tissues and plasma of several sphingolipidoses. As shown earlier by us, sphingoid bases can be accurately quantified using UPLC-ESI-MS/MS, particularly in combination with identical 13 C-encoded internal standards. The feasibility of simultaneous quantitation of sphingoid bases in plasma specimens spiked with a mixture of such standards is here described. The sensitivity and linearity of detection is excellent for all examined sphingoid bases (sphingosine, sphinganine, hexosyl-sphingosine (glucosylsphingosine), hexosyl 2 -sphingosine (lactosylsphingosine), hexosyl 3 -sphingosine (globotriaosylsphingosine), phosphorylcholine-sphingosine) in the relevant concentration range and the measurements show very acceptable intra- and inter-assay variation (<10% average). Plasma samples of a series of male and female Gaucher Disease and Fabry Disease patients were analyzed with the multiplex assay. The obtained data compare well to those earlier determined for plasma globotriaosylsphingosine and glucosylsphingosine in GD and FD patients. The same approach can be also applied to measure sphingolipids in the same sample. Following extraction of sphingolipids from the same sample these can be converted to sphingoid bases by microwave exposure and subsequently quantified using 13 C-encoded internal standards. Copyright © 2017 Elsevier B.V. All rights reserved.
Frazier, Melanie; Miller, A. Whitman; Lee, Henry; Reusser, Deborah A.
2013-01-01
Discharge from the ballast tanks of ships is one of the primary vectors of nonindigenous species in marine environments. To mitigate this environmental and economic threat, international, national, and state entities are establishing regulations to limit the concentration of living organisms that may be discharged from the ballast tanks of ships. The proposed discharge standards have ranged from zero detectable organisms to 3. If standard sampling methods are used, verifying whether ballast discharge complies with these stringent standards will be challenging due to the inherent stochasticity of sampling. Furthermore, at low concentrations, very large volumes of water must be sampled to find enough organisms to accurately estimate concentration. Despite these challenges, adequate sampling protocols comprise a critical aspect of establishing standards because they help define the actual risk level associated with a standard. A standard that appears very stringent may be effectively lax if it is paired with an inadequate sampling protocol. We describe some of the statistical issues associated with sampling at low concentrations to help regulators understand the uncertainties of sampling as well as to inform the development of sampling protocols that ensure discharge standards are adequately implemented.
Jiang, Ting-Fu; Lv, Zhi-Hua; Wang, Yuan-Hong; Yue, Mei-E
2006-06-01
A new, simple and rapid capillary electrophoresis (CE) method, using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier, was developed for the identification and quantitative determination of four plant hormones, including gibberellin A3 (GA3), indole-3-acetic acid (IAA), alpha-naphthaleneacetic acid (NAA) and 4-chlorophenoxyacetic acid (4-CA). The optimum separation was achieved with 20 mM borate buffer at pH 10.00 containing 0.005% (w/v) of HDB. The applied voltage was -25 kV and the capillary temperature was kept constant at 25 degrees C. Salicylic acid was used as internal standard for quantification. The calibration dependencies exhibited good linearity within the ratios of the concentrations of standard samples and internal standard and the ratios of the peak areas of samples and internal standard. The correlation coefficients were from 0.9952 to 0.9997. The relative standard deviations of migration times and peak areas were < 1.93 and 6.84%, respectively. The effects of buffer pH, the concentration of HDB and the voltage on the resolution were studied systematically. By this method, the contents of plant hormone in biofertilizer were successfully determined within 7 min, with satisfactory repeatability and recovery.
Sil'veĭstrova, O Iu; Domonova, É A; Shipulina, O Iu
2014-04-01
The validation of kit of reagents destined to detection and quantitative evaluation of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode was implemented. The comparison was made against international WHO standard--The first WHO international standard for human cytomegalovirus to implement measures the kit of reagents "AmpliSens CMV-screen/monitor-FL" and standard sample of enterprise DNA HCMV (The central research institute of epidemiology of Rospotrebnadzor) was applied. The fivefold dilution of international WHO standard and standard sample of enterprise were carried out in concentrations of DNA HCMV from 106 to 102. The arrangement of polymerase chain reaction and analysis of results were implemented using programed amplifier with system of detection of fluorescent signal in real-time mode "Rotor-Gene Q" ("Qiagen", Germany). In the total of three series of experiments, all stages of polymerase chain reaction study included, the coefficient of translation of quantitative evaluation of DNA HCMV from copy/ml to ME/ml equal to 0.6 was introduced for this kit of reagents.
Pugsley, Haley R.; Swearingen, Kristian E.; Dovichi, Norman J.
2009-01-01
A number of algorithms have been developed to correct for migration time drift in capillary electrophoresis. Those algorithms require identification of common components in each run. However, not all components may be present or resolved in separations of complex samples, which can confound attempts for alignment. This paper reports the use of fluorescein thiocarbamyl derivatives of amino acids as internal standards for alignment of 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ)-labeled proteins in capillary sieving electrophoresis. The fluorescein thiocarbamyl derivative of aspartic acid migrates before FQ-labeled proteins and the fluorescein thiocarbamyl derivative of arginine migrates after the FQ-labeled proteins. These compounds were used as internal standards to correct for variations in migration time over a two-week period in the separation of a cellular homogenate. The experimental conditions were deliberately manipulated by varying electric field and sample preparation conditions. Three components of the homogenate were used to evaluate the alignment efficiency. Before alignment, the average relative standard deviation in migration time for these components was 13.3%. After alignment, the average relative standard deviation in migration time for these components was reduced to 0.5%. PMID:19249052
7 CFR 51.481 - Very good internal quality.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Very good internal quality. 51.481 Section 51.481 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... quality. Very good internal quality means that the combined juice from the edible portion of a sample of...
[Analysis of heavy metals monitoring results in food in Shaoxing in 2014].
Fan, Wei; Wang, Jing; Wu, Hongmiao; Lian, Lingjun; Du, Sai; Chen, Li
2015-11-01
To investigate heavy metals contamination level in food in Shaoxing, and to provide basis evidence for supervising heavy metals pollution in food and environmental pollution control in Shaoxing. Food samples in 2014 were detected for lead, cadmium, mercury, arsenic, nickel, copper and chromium by national standard methods, and the results were evaluated by GB 2762-2012 Pollutants limits in food. 1384 samples from 10 food categories were collected and tested for lead, cadmium, mercury and arsenic, the over standard rates were 2.0%, 3.0%, 1.5% and 0.22%, respectively, the median were 0.019, 0.0085, 0.0024 and 0.015 mg/kg, respectively; 273 samples were collected and tested for nickel, the detection rate was 48.4%, the median was 0.010 mg/kg; 255 samples were collected and tested for chromium, the detection rate was 14.9%, the median was 0.0050 mg/kg; 486 samples were collected and tested for copper, the detection rate was 94.0%, the median was 1.34 mg/kg. The heavy metals over standard rate of aquatic products, animal internal organs and grain were relatively high, 16.9%, 7.9% and 7.3% cadmium in swimming crabs exceeded standard seriously, the over standard rate was 38.9%. The overall pollution of heavy metals in food are not high in Shaoxing in 2014, but some food (aquatic products, animal internal organs and grain) pollution are relatively outstanding, and have the over standard problems of lead, cadmium, mercury and arsenic.
NASA Astrophysics Data System (ADS)
Wellenreuther, G.; Fittschen, U. E. A.; Achard, M. E. S.; Faust, A.; Kreplin, X.; Meyer-Klaucke, W.
2008-12-01
Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence (μXRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.
Ferguson, Morag; Heath, Alan
2004-12-01
Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum potency in IU of vaccines released for use and which meet the current minimum potency of 10(3) LD(50) in mouse assays, can be determined. These data will be analysed before a review of the WHO requirements, including the minimum potency per dose, is undertaken.
Blümcke, Ingmar; Aronica, Eleonora; Miyata, Hajime; Sarnat, Harvey B; Thom, Maria; Roessler, Karl; Rydenhag, Bertil; Jehi, Lara; Krsek, Pavel; Wiebe, Samuel; Spreafico, Roberto
2016-03-01
Epilepsy surgery is an effective treatment in many patients with drug-resistant focal epilepsies. An early decision for surgical therapy is facilitated by a magnetic resonance imaging (MRI)-visible brain lesion congruent with the electrophysiologically abnormal brain region. Recent advances in the pathologic diagnosis and classification of epileptogenic brain lesions are helpful for clinical correlation, outcome stratification, and patient management. However, application of international consensus classification systems to common epileptic pathologies (e.g., focal cortical dysplasia [FCD] and hippocampal sclerosis [HS]) necessitates standardized protocols for neuropathologic workup of epilepsy surgery specimens. To this end, the Task Force of Neuropathology from the International League Against Epilepsy (ILAE) Commission on Diagnostic Methods developed a consensus standard operational procedure for tissue inspection, distribution, and processing. The aims are to provide a systematic framework for histopathologic workup, meeting minimal standards and maximizing current and future opportunities for morphofunctional correlations and molecular studies for both clinical care and research. Whenever feasible, anatomically intact surgical specimens are desirable to enable systematic analysis in selective hippocampectomies, temporal lobe resections, and lesional or nonlesional neocortical samples. Correct orientation of sample and the sample's relation to neurophysiologically aberrant sites requires good communication between pathology and neurosurgical teams. Systematic tissue sampling of 5-mm slabs along a defined anatomic axis and application of a limited immunohistochemical panel will ensure a reliable differential diagnosis of main pathologies encountered in epilepsy surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.
Holá, Markéta; Kanický, Viktor; Mermet, Jean-Michel; Otruba, Vítezslav
2003-12-01
The potential of the laser-induced argon spark atomizer (LINA-Spark atomizer) coupled with ICP-AES as a convenient device for direct analysis of WC/Co powdered precursors of sintered hardmetals was studied. The samples were presented for the ablation as pressed pellets prepared by mixing with powdered silver binder containing GeO2 as internal standard. The pellets were ablated with the aid of a Q-switched Nd:YAG laser (1064 nm) focused 16 mm behind the target surface with a resulting estimated power density of 5 GW cm(-2). Laser ablation ICP-AES signals were studied as a function of ablation time, and the duration of time prior to measurement (pre-ablation time) which was necessary to obtain reliable results was about 40 s. Linear calibration plots were obtained up to 10% (m/m) Ti, 9% Ta and 3.5% Nb both without internal standardization and by using germanium as an added internal standard or tungsten as a contained internal standard. The relative uncertainty at the centroid of the calibration line was in the range from +/- 6% to +/- 11% for Nb, Ta and Ti both with and without internal standardisation by Ge. A higher spread of points about the regression was observed for cobalt for which the relative uncertainty at the centroid was in the range from +/- 9% to +/- 14%. Repeatability of results was improved by the use of both Ge and W internal standards. The lowest determinable quantities calculated for calibration plots were 0.060% Co, 0.010% Nb, 0.16% Ta and 0.030% Ti with internal standardization by Ge. The LA-ICP-AES analyses of real samples led to good agreement with the results obtained by solution-based ICP determination with a relative bias not exceeding 10%. The elimination of the dissolution procedure of powdered tungsten (Nb, Ta, Ti) carbide is the principal advantage of the developed LA-ICP-AES method.
ERIC Educational Resources Information Center
Laurson, Kelly R.; Welk, Gregory J.; Marton, Orsolya; Kaj, Mónika; Csányi, Tamás
2015-01-01
Purpose: This study examined agreement between all 3 standards (as well as relative diagnostic associations with metabolic syndrome) using a representative sample of youth from the Hungarian National Youth Fitness Study. Method: Body mass index (BMI) was assessed in a field sample of 2,352 adolescents (ages 10-18.5 years) and metabolic syndrome…
Investigation into low-level anti-rubella virus IgG results reported by commercial immunoassays.
Dimech, Wayne; Arachchi, Nilukshi; Cai, Jingjing; Sahin, Terri; Wilson, Kim
2013-02-01
Since the 1980s, commercial anti-rubella virus IgG assays have been calibrated against a WHO International Standard and results have been reported in international units per milliliter (IU/ml). Laboratories testing routine patients' samples collected 100 samples that gave anti-rubella virus IgG results of 40 IU/ml or less from each of five different commercial immunoassays (CIA). The total of 500 quantitative results obtained from 100 samples from each CIA were compared with results obtained from an in-house enzyme immunoassay (IH-EIA) calibrated using the WHO standard. All 500 samples were screened using a hemagglutination inhibition assay (HAI). Any sample having an HAI titer of 1:8 or less was assigned a negative anti-rubella virus antibody status. If the HAI titer was greater than 1:8, the sample was tested in an immunoblot (IB) assay. If the IB result was negative, the sample was assigned a negative anti-rubella virus IgG status; otherwise, the sample was assigned a positive status. Concordance between the CIA qualitative results and the assigned negative status ranged from 50.0 to 93.8% and 74.5 to 97.8% for the assigned positive status. Using a receiver operating characteristic analysis with the cutoff set at 10 IU/ml, the estimated sensitivity and specificity ranged from 70.2 to 91.2% and 65.9 to 100%, respectively. There was poor correlation between the quantitative CIA results and those obtained by the IH-EIA, with the coefficient of determination (R(2)) ranging from 0.002 to 0.413. Although CIAs have been calibrated with the same international standard for more than 2 decades, the level of standardization continues to be poor. It may be time for the scientific community to reevaluate the relevance of quantification of anti-rubella virus IgG.
Investigation into Low-Level Anti-Rubella Virus IgG Results Reported by Commercial Immunoassays
Arachchi, Nilukshi; Cai, Jingjing; Sahin, Terri; Wilson, Kim
2013-01-01
Since the 1980s, commercial anti-rubella virus IgG assays have been calibrated against a WHO International Standard and results have been reported in international units per milliliter (IU/ml). Laboratories testing routine patients' samples collected 100 samples that gave anti-rubella virus IgG results of 40 IU/ml or less from each of five different commercial immunoassays (CIA). The total of 500 quantitative results obtained from 100 samples from each CIA were compared with results obtained from an in-house enzyme immunoassay (IH-EIA) calibrated using the WHO standard. All 500 samples were screened using a hemagglutination inhibition assay (HAI). Any sample having an HAI titer of 1:8 or less was assigned a negative anti-rubella virus antibody status. If the HAI titer was greater than 1:8, the sample was tested in an immunoblot (IB) assay. If the IB result was negative, the sample was assigned a negative anti-rubella virus IgG status; otherwise, the sample was assigned a positive status. Concordance between the CIA qualitative results and the assigned negative status ranged from 50.0 to 93.8% and 74.5 to 97.8% for the assigned positive status. Using a receiver operating characteristic analysis with the cutoff set at 10 IU/ml, the estimated sensitivity and specificity ranged from 70.2 to 91.2% and 65.9 to 100%, respectively. There was poor correlation between the quantitative CIA results and those obtained by the IH-EIA, with the coefficient of determination (R2) ranging from 0.002 to 0.413. Although CIAs have been calibrated with the same international standard for more than 2 decades, the level of standardization continues to be poor. It may be time for the scientific community to reevaluate the relevance of quantification of anti-rubella virus IgG. PMID:23254301
Ring, P R; Bostick, J M
2000-04-01
A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.
Statistical considerations in estimating organism concentrations in ballast water discharges
Sampling probabilities may affect the practical use of different ballast water performance standards which establish the acceptable concentration of organisms in ballast discharges. The International Maritime Organization (IMO) has initiated a ballast water standard of <10 viabl...
ERIC Educational Resources Information Center
Lord, Janet E.
This document is designed to prepare advocates in the international disability community for productive participation in the development of international conventions on the human rights of people with disabilities. Knowledge of the standard categories of international law provisions will help participants address issues related to the structure of…
Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor
2009-10-01
A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.
Do Australian immunoglobulin products meet international measles antibody titer standards?
Young, Megan K; Bertolini, Joseph; Kotharu, Pushpa; Maher, Darryl; Cripps, Allan W
2017-03-04
The effectiveness of passive immunisation post-exposure to measles appears subject to a dose-response effect. New Zealand and the United Kingdom have increased the recommended dose of polyclonal human immunoglobulin for post-exposure prophylaxis within the last decade in response to concerns about decreasing levels of measles antibodies in these products. This study used the plaque-reduction neutralization test (PRNT) to measure the titer of measles-specific antibodies in Australian immunoglobulin products for post-exposure prophylaxis and compared the utility of an enzyme-linked immunosorbent assay (ELISA) to the PRNT in available Australian and international samples: Australian intramuscular (n = 10), Australian intravenous (n = 28), New Zealand intramuscular (n = 2), Hizentra (subcutaneous)(USA) (n = 3), and Privigen (intravenous)(USA) (n = 2). Measles titres in Australian IM and IV immunoglobulins ranged from 51 to 76 IU/mL and 6 to 24 IU/mL respectively, as measured by PRNT calibrated to the WHO 3 rd international standard. ELISA titres were variable but higher than PRNT titres in all tested samples. Measles antibody titres in Australian immunoglobulin products meet consensus-prescribed international thresholds. Development of a convenient, standardized, readily accessible assay for determination of measles titres in immunoglobulin products would be useful for future studies and facilitate international comparisons.
U.S. Muslim women and body image: links among objectification theory constructs and the hijab.
Tolaymat, Lana D; Moradi, Bonnie
2011-07-01
This study tested tenets of objectification theory and explored the role of the hijab in body image and eating disorder symptoms with a sample of 118 Muslim women in the United States. Results from a path analysis indicated that individual differences in wearing the hijab were related negatively with reported sexual objectification experiences. Sexual objectification experiences, in turn, had significant positive indirect relations with body surveillance, body shame, and eating disorder symptoms, primarily through the mediating role of internalization. Internalization of cultural standards of beauty also had a significant positive direct relation with body shame and significant positive direct and indirect relations with eating disorder symptoms. By contrast, the direct and indirect relations of body surveillance were significant only when the role of internalization was constrained to 0 (i.e., eliminated), suggesting that internalization of cultural standards of beauty subsumed the hypothesized role of body surveillance in the model. Taken together, these results support some of the tenets of objectification theory with a sample of U.S. Muslim women, point to the importance of internalization of dominant cultural standards of beauty within that framework, and suggest the utility of considering individual differences in wearing the hijab among U.S. Muslim women.
Credit risk migration rates modeling as open systems: A micro-simulation approach
NASA Astrophysics Data System (ADS)
Landini, S.; Uberti, M.; Casellina, S.
2018-05-01
The last financial crisis of 2008 stimulated the development of new Regulatory Criteria (commonly known as Basel III) that pushed the banking activity to become more prudential, either in the short and the long run. As well known, in 2014 the International Accounting Standards Board (IASB) promulgated the new International Financial Reporting Standard 9 (IFRS 9) for financial instruments that will become effective in January 2018. Since the delayed recognition of credit losses on loans was identified as a weakness in existing accounting standards, the IASB has introduced an Expected Loss model that requires more timely recognition of credit losses. Specifically, new standards require entities to account both for expected losses from when the impairments are recognized for the first time and for full loan lifetime; moreover, a clear preference toward forward looking models is expressed. In this new framework, it is necessary a re-thinking of the widespread standard theoretical approach on which the well known prudential model is founded. The aim of this paper is then to define an original methodological approach to migration rates modeling for credit risk which is innovative respect to the standard method from the point of view of a bank as well as in a regulatory perspective. Accordingly, the proposed not-standard approach considers a portfolio as an open sample allowing for entries, migrations of stayers and exits as well. While being consistent with the empirical observations, this open-sample approach contrasts with the standard closed-sample method. In particular, this paper offers a methodology to integrate the outcomes of the standard closed-sample method within the open-sample perspective while removing some of the assumptions of the standard method. Three main conclusions can be drawn in terms of economic capital provision: (a) based on the Markovian hypothesis with a-priori absorbing state at default, the standard closed-sample method is to be abandoned for not to predict lenders' bankruptcy by construction; (b) to meet more reliable estimates along with the new regulatory standards, the sample to estimate migration rates matrices for credit risk should include either entries and exits; (c) the static eigen-decomposition standard procedure to forecast migration rates should be replaced with a stochastic process dynamics methodology while conditioning forecasts to macroeconomic scenarios.
Rønning, Helene Thorsen; Einarsen, Kristin; Asp, Tone Normann
2006-06-23
A simple and rapid method for the determination and confirmation of chloramphenicol in several food matrices with LC-MS/MS was developed. Following addition of d5-chloramphenicol as internal standard, meat, seafood, egg, honey and milk samples were extracted with acetonitrile. Chloroform was then added to remove water. After evaporation, the residues were reconstituted in methanol/water (3+4) before injection. The urine and plasma samples were after addition of internal standard applied to a Chem Elut extraction cartridge, eluted with ethyl acetate, and hexane washed. Also these samples were reconstituted in methanol/water (3+4) after evaporation. By using an MRM acquisition method in negative ionization mode, the transitions 321-->152, 321-->194 and 326-->157 were used for quantification, confirmation and internal standard, respectively. Quantification of chloramphenicol positive samples regardless of matrix could be achieved with a common water based calibration curve. The validation of the method was based on EU-decision 2002/657 and different ways of calculating CCalpha and CCbeta were evaluated. The common CCalpha and CCbeta for all matrices were 0.02 and 0.04 microg/kg for the 321-->152 ion transition, and 0.02 and 0.03 microg/kg for the 321-->194 ion transition. At fortification level 0.1 microg/kg the within-laboratory reproducibility is below 25%.
Analysis of penicillin G in milk by liquid chromatography.
Boison, J O; Keng, L J; MacNeil, J D
1994-01-01
A liquid chromatographic (LC) method that was previously developed for penicillin G residues in animal tissues has been adapted to milk and milk products. After protein precipitation with sodium tungstate, samples are applied to a C18 solid-phase extraction cartridge, from which penicillin is eluted, derivatized with 1,2,4-triazole-mercuric chloride solution, and analyzed by isocratic liquid chromatography (LC) on a C18 column with UV detection at 325 nm. Quantitation is done with reference to penicillin V as an internal standard. Penicillin G recoveries were determined to be > 70% on standards fortified at 3-60 ppb. Accuracy approached 100% using the penicillin V internal standard. The detection limit for penicillin G residues was 3 ppb in fluid milk. Samples may be confirmed by thermospray/LC at concentrations approaching the detection limit of the UV method.
Van De Steene, Jet C; Lambert, Willy E
2008-05-01
When developing an LC-MS/MS-method matrix effects are a major issue. The effect of co-eluting compounds arising from the matrix can result in signal enhancement or suppression. During method development much attention should be paid to diminishing matrix effects as much as possible. The present work evaluates matrix effects from aqueous environmental samples in the simultaneous analysis of a group of 9 specific pharmaceuticals with HPLC-ESI/MS/MS and UPLC-ESI/MS/MS: flubendazole, propiconazole, pipamperone, cinnarizine, ketoconazole, miconazole, rabeprazole, itraconazole and domperidone. When HPLC-MS/MS is used, matrix effects are substantial and can not be compensated for with analogue internal standards. For different surface water samples different matrix effects are found. For accurate quantification the standard addition approach is necessary. Due to the better resolution and more narrow peaks in UPLC, analytes will co-elute less with interferences during ionisation, so matrix effects could be lower, or even eliminated. If matrix effects are eliminated with this technique, the standard addition method for quantification can be omitted and the overall method will be simplified. Results show that matrix effects are almost eliminated if internal standards (structural analogues) are used. Instead of the time-consuming and labour-intensive standard addition method, with UPLC the internal standardization can be used for quantification and the overall method is substantially simplified.
McClure, Foster D; Lee, Jung K
2005-01-01
Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.
Coplen, Tyler B.
2010-01-01
Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.
Blair, D; Rumack, B H
1977-01-01
We describe a capillary-sampling method for serum or plasma acetaminophen by cation-exchange chromatography. As little as 1.5 mul of plasma or serum and an equal volume of the internal standard (N-butyryl-p-aminophenol) were run, with a precision of +/- 5% between duplicates. Acetaminophen and the internal standard chromatographed in 32 and 50 min, respectively, distinct from intrinsic plasma peaks and peaks caused by other medications.
Evans, Travis C; Britton, Jennifer C
2018-09-01
Abnormal threat-related attention in anxiety disorders is most commonly assessed and modified using the dot-probe paradigm; however, poor psychometric properties of reaction-time measures may contribute to inconsistencies across studies. Typically, standard attention measures are derived using average reaction-times obtained in experimentally-defined conditions. However, current approaches based on experimentally-defined conditions are limited. In this study, the psychometric properties of a novel response-based computation approach to analyze dot-probe data are compared to standard measures of attention. 148 adults (19.19 ± 1.42 years, 84 women) completed a standardized dot-probe task including threatening and neutral faces. We generated both standard and response-based measures of attention bias, attentional orientation, and attentional disengagement. We compared overall internal consistency, number of trials necessary to reach internal consistency, test-retest reliability (n = 72), and criterion validity obtained using each approach. Compared to standard attention measures, response-based measures demonstrated uniformly high levels of internal consistency with relatively few trials and varying improvements in test-retest reliability. Additionally, response-based measures demonstrated specific evidence of anxiety-related associations above and beyond both standard attention measures and other confounds. Future studies are necessary to validate this approach in clinical samples. Response-based attention measures demonstrate superior psychometric properties compared to standard attention measures, which may improve the detection of anxiety-related associations and treatment-related changes in clinical samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
Soyuz 27 Return Samples: Air Quality Aboard the International Space Station: Revised
NASA Technical Reports Server (NTRS)
James, John T.
2012-01-01
The toxicological assessment of 6 GSCs from the ISS is shown. The average recoveries of the 3 surrogate standards from the grab sample containers were as follows: C-13-acetone, 115%; fluorobenzene, 108%; and chlorobenzene, 93%.
Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao
2015-01-01
The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.
Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M
2012-11-08
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.
Onofrejová, Lucia; Farková, Marta; Preisler, Jan
2009-04-13
The application of an internal standard in quantitative analysis is desirable in order to correct for variations in sample preparation and instrumental response. In mass spectrometry of organic compounds, the internal standard is preferably labelled with a stable isotope, such as (18)O, (15)N or (13)C. In this study, a method for the quantification of fructo-oligosaccharides using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI TOF MS) was proposed and tested on raftilose, a partially hydrolysed inulin with a degree of polymeration 2-7. A tetraoligosaccharide nystose, which is chemically identical to the raftilose tetramer, was used as an internal standard rather than an isotope-labelled analyte. Two mathematical approaches used for data processing, conventional calculations and artificial neural networks (ANN), were compared. The conventional data processing relies on the assumption that a constant oligomer dispersion profile will change after the addition of the internal standard and some simple numerical calculations. On the other hand, ANN was found to compensate for a non-linear MALDI response and variations in the oligomer dispersion profile with raftilose concentration. As a result, the application of ANN led to lower quantification errors and excellent day-to-day repeatability compared to the conventional data analysis. The developed method is feasible for MS quantification of raftilose in the range of 10-750 pg with errors below 7%. The content of raftilose was determined in dietary cream; application can be extended to other similar polymers. It should be stressed that no special optimisation of the MALDI process was carried out. A common MALDI matrix and sample preparation were used and only the basic parameters, such as sampling and laser energy, were optimised prior to quantification.
Basic and Morphological Properties of Bukit Goh Bauxite
NASA Astrophysics Data System (ADS)
Hasan, Muzamir; Nor Azmi, Ahmad Amirul Faez Ahmad; Tam, Weng Long; Phang, Biao Yu; Azizul Moqsud, M.
2018-03-01
Investigation conducted by International Maritime Organization (IMO) concluded that the loss of the Bulk Jupiter that carrying bauxite from Kuantan has uncovered evidence to suggest liquefaction led to loss of stability. This research analysed Bukit Goh bauxite and comparison was made with International Maritime Solid Bulk Cargoes (IMSBC Code) standard. To analyse these characteristics of the bauxite, four samples were selected at Bukit Goh, Kuantan ; two of the samples from the Bukit Goh mine and two samples from the stock piles were tested to identify the bauxite basic and morphological properties by referring to GEOSPEC 3 : Model Specification for Soil Testing ; particle size distribution, moisture content and specific gravity and its morphological properties. Laboratory tests involved including Hydrometer test, Small Pycnometer test, Dry Sieve test and Field Emission Scanning Electron Microscop (FESEM) test. The results show that the average moisture content of raw Bukit Goh bauxite is 20.64% which exceeded the recomended value of maximum 10%. Average fine material for raw bauxite is 37.75% which should not be greater than 30% per IMSBC standard. By that, the bauxite from Bukit Goh mine do not achieved the minimum requirements and standards of the IMSBC standard and need to undergo beneficiation process for better quality and safety.
Preiksaitis, J.; Tong, Y.; Pang, X.; Sun, Y.; Tang, L.; Cook, L.; Pounds, S.; Fryer, J.; Caliendo, A. M.
2015-01-01
Quantitative detection of cytomegalovirus (CMV) DNA has become a standard part of care for many groups of immunocompromised patients; recent development of the first WHO international standard for human CMV DNA has raised hopes of reducing interlaboratory variability of results. Commutability of reference material has been shown to be necessary if such material is to reduce variability among laboratories. Here we evaluated the commutability of the WHO standard using 10 different real-time quantitative CMV PCR assays run by eight different laboratories. Test panels, including aliquots of 50 patient samples (40 positive samples and 10 negative samples) and lyophilized CMV standard, were run, with each testing center using its own quantitative calibrators, reagents, and nucleic acid extraction methods. Commutability was assessed both on a pairwise basis and over the entire group of assays, using linear regression and correspondence analyses. Commutability of the WHO material differed among the tests that were evaluated, and these differences appeared to vary depending on the method of statistical analysis used and the cohort of assays included in the analysis. Depending on the methodology used, the WHO material showed poor or absent commutability with up to 50% of assays. Determination of commutability may require a multifaceted approach; the lack of commutability seen when using the WHO standard with several of the assays here suggests that further work is needed to bring us toward true consensus. PMID:26269622
[Determination of heavy metals in four traditional Chinese medicines by ICP-MS].
Wen, Hui-Min; Chen, Xiao-Hui; Dong, Ting-Xia; Zhan, Hua-Qiang; Bi, Kai-Shun
2006-08-01
To establish a ICP-MS method for the determination of heavy metals, including As, Hg, Pb, Cd, in four traditional Chinese medicines. The samples were digested by closed-versel microwave. The four heavy metals were directly analyzed by ICP-MS. Select internal standard element in for the method by which the analyse signal drife is corrected by the signal of another element (internal standard elements) added to both the standard solution and sample. For all of the analyzed heary methals, the correlative coefficient of the calibration curves was over 0.999 2. The recovery rates of the procedure were 97.5%-108.0%, and its RSD was lower than 11.6%. This method was convenient, quick-acquired, accurate and highly sensitive. The method can be used for the quality control of trace elements in traditional Chinese medicines and for the contents determination of traditional Chinese medicines from different habitats and species.
Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua
2014-05-01
The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.
A new analytical approach for the sampling and analysis of volatile organic compounds (VOCs) from sampling platforms used in the vertical profiling of the lower troposphere, such as kites, balloons, and remotely piloted vehicles will be developed. These sampling platforms a...
Simonsen, H; Jensen, U G
1999-12-01
Quantitative analysis of amino acids (AA) and acylcarnitines using tandem mass spectrometry is an emerging technology used to screen neonatal dried blood spot samples for disorders in the metabolism of AA, organic acids and fatty acids. This paper provides a brief review of some of the technically oriented issues which emerged at the 4th meeting of the International Society for Neonatal Screening in Stockholm, 1999. The information covers sample preparation, instrumentation, data acquistion modes, internal standards, interpretation, confounding factors and practical screening experience.
Comparison and harmonization of measuring methods for air contaminants in the working environment.
Leichnitz, K
1998-09-01
The objective of this work was to demonstrate that the measurement of air contaminants in the workplace requires a special approach. Decisive in carrying out the measuring task is the quality of the sampling strategy, including selection of the appropriate measuring method. Methods developed at a national level may be more suitable for this purpose than methods described in international standards. Measurements of air contaminants in the workplace should always be the basis for the prevention and control of occupational hazards. Such measurements, therefore, are also an essential element of risk assessment. Industrial processes and chemical agents are myriad. Each manufacturing stage may apply different conditions (e.g., batch production or continuous process, temperature, pressure) and agents (e.g. a wide variety of chemical substances): In each of these stages, different job functions may be necessary and may be subject to different exposure conditions. Distance from emission sources and physical parameters, such as rates of release, air current, meteorological variations, also have a profound influence. The measuring task in the workplace is quite different in comparison to many others (e.g., blood or soil sample analysis). Firstly, the selection of sampling time and sampling location are crucial steps in air analysis. Transportation and storage of the samples, may however, also influence measuring results; interlaboratory tests show the existing problems. Generally, in analytics, the substance to be determined remains "well covered" in its matrix during sampling, transportation and storage. In air analysis, however, the contaminant is usually "torn" from its surrounding matrix (the air) and "forced" into the sorbent, where it finds a completely new environment; reactions yielding artefacts may take place. Several international organizations have issued guidelines and standards on measuring methods for air contaminants in the working environment, such as the World Health Organization (WHO), the International Union of Pure and Applied Chemistry (IUPAC), and the International Organization for Standardization (ISO). Most of these international documents are substance-related and mainly cover the analytical steps, which constitute only part of the whole measuring process. The approach of the Commission of the European Union is useful in solving the task of air testing in the workplace. This body has issued an EU Directive which includes general requirements for measuring methods. In the Directive it is also stated that persons who carry out measurements must possess the necessary expertise. The Directive, in addition, refers to the European Committee for Standardization (CEN), and that to general requirements for measuring procedures. The advantage of the EU/CEN approach is its aspect of general requirements. This allows the development of new or improved methods without any restricting effect on existing substance-related standards.
Liu, Fang; Ren, Dequan; Guo, De-an; Pan, Yifeng; Zhang, Huzhe; Hu, Ping
2008-03-01
In this paper, a new method for liquid chromatographic fingerprint of saponins in Gynostemma pentaphyllum (THUNB.) MAKINO was developed. The G. pentaphyllum powder was defatted by Soxhlet extraction with petroleum ether and then gypenosides were extracted from the residue with methanol by sonicating. Column chromatography with macro pore resin was then used to separate and enrich gypenosides. HPLC fingerprint analysis of gypenosides fraction was performed on a C18 column, with an isocratic elution of 34% acetonitrile for 60 min at 0.8 ml/min, sample injection volume was 20 microl and the wavelength was 203 nm. To cover the lack of standard compounds, the addition of an internal standard of ginsenoside Rb2 was employed in the gypenosides fingerprint profile. The relative retention time (RRT) and relative peak area (RPA) of the gypenosides peaks in the fingerprint were calculated by setting the ginsenoside Rb2 as the marker compound. The relative standard deviation (RSDs) of RRT of five common peaks vs. ginsenoside Rb2 in precision, repeatability and stability test were less than 1%, and the RSDs of RPA were less than 5%. The method validation data proved that the proposed method for the fingerprint with internal standard of G. pentaphyllum saponins is adequate, valid and applicable. Finally, three batches of crude drug samples collected from Shanxi province were tested by following the established method.
Spectrochemical determination of thorium in monazite by the powder-d.c. arc technique
Dutra, C.V.; Murata, K.J.
1954-01-01
Thorium in monazite is determined by a d.c. carbon-arc technique using zirconium as the internal standard. The analytical curve for Th II 2870.413 A??/Zr II 2844-579 A?? is established by means of synthetic standards containing graduated amounts of thoria and 0.500 per cent zirconia in pegmatite base (60 parts quartz, 40 parts microchne, and 1 part ferric oxide). Monazite samples are diluted 14-fold with pegmatite base that contains 0.538 per cent ZrO2, so that the zirconia content of the resulting mixture is also 0.500 per cent. In addition, both the standards and the diluted monazites are mixed with one-half their weight of powdered graphite. Approximately 25 mg of the prepared samples are arced to completion at 15.5 to 17.5 amperes. With the 14-fold dilution employed, the accurate range of the method is 3 to 20 per cent thoria in the original monazite. The coefficient of variation for a single determination is 4 per cent at the 7 per cent thoria level. Tests with synthetic unknowns and chemically analyzed monazites show a maximum error of ??10 per cent of the thoria content. If niobium is substituted for zirconium as the internal standard, there is a loss of precision. Platinum as the internal standard gives results of good precision but introduces a marked sensitivity to matrix effects. ?? 1954.
Fischer, Axel R; Lan, Nham Thi Phuong; Wiedemann, Cornelia; Heide, Petra; Werner, Peter; Schmidt, Arndt W; Theumer, Gabriele; Knölker, Hans-Joachim
2010-04-23
A new method for determining the endocrine disrupting substance 4-nonylphenol (technical grade=mixture of isomers, 4-NP) from water samples has been developed by using 4-(2,6-dimethylhept-3-yl)phenol (4-sec-NP) as model compound. This branched monoalkylphenol is shown to serve as internal standard (IS) for the determination of technical 4-nonylphenol. To the best of our knowledge, 4-(2,6-dimethylhept-3-yl)phenol (racemic mixture) is a newly synthesized 4-nonylphenol isomer and has not been described elsewhere. Recoveries have been determined by analyzing spiked water samples from distilled water, river water and wastewater. Following acetylation, the compounds were enriched via solid phase extraction (SPE). Analyses of the compounds were performed by capillary column gas chromatography/mass spectrometry (GC/MS), operating in selected ion-monitoring (SIM) mode. The recovery of technical 4-NP using either the newly prepared 4-sec-NP or 4-n-nonylphenol (4-n-NP) as IS have been compared. 4-sec-NP showed slightly better results. However, in the first series of experiments using wastewater, the yields for the derivatization of the two standard compounds were remarkably different. The yield for derivatization of 4-n-NP was approximately 20%, probably due to the difficult matrix of the wastewater. In contrast, the yield for the derivatization of 4-sec-NP was considerably higher (approximately 63%). This problem can be solved by increasing the concentration of the reagent used for derivatization. For better control of the clean-up process, we recommend application of 4-sec-NP as internal standard, at least in water samples with complex matrices (e.g., high content of hydroxylated compounds). Copyright 2010 Elsevier B.V. All rights reserved.
Ong, Jane Jun-Xin; Steele, Catriona M; Duizer, Lisa M
2018-06-01
Sensory characteristics are important for the acceptance of thickened liquids, but those of liquids thickened to the new standards put forth by the International Dysphagia Diet Standardization Initiative (IDDSI) are unknown. This research sought to identify and rate the perception of important sensory properties of liquids thickened to levels specified in the IDDSI framework. Samples were made with water, with and without added barium sulfate, and were thickened with a cornstarch or xanthan gum based thickener. Samples were characterized using projective mapping/ultra-flash profiling to identify important sample attributes, and then with trained descriptive analysis panels to characterize those attributes in non-barium and barium thickened liquids. Three main groups of attributes were observed. Taste and flavor attributes decreased in intensity with increasing thickener. Thickener specific attributes included graininess and chalkiness for the cornstarch thickened samples, and slipperiness for the xanthan gum samples. Within the same type of thickener, ratings of thickness-related attributes (perceived viscosity, adhesiveness, manipulation, and swallowing) at different IDDSI levels were significantly different from each other. However, in non-barium samples, cornstarch samples were perceived as thicker than xanthan gum samples even though they had similar apparent viscosities at 50 s -1 . On the other hand, the two thickeners had similar perceived thickness in the barium samples even though the apparent viscosities of cornstarch samples were higher than those of the xanthan gum samples. In conclusion, IDDSI levels can be distinguished based on sensory properties, but these properties may be affected by the type of thickener and medium being thickened.
Enforcement of food packaging legislation.
van Lierop, J B
1997-01-01
A survey of the results of the analysis of samples of packaging materials, obtained from the Dutch market during the last 5 years is presented. The diethylether extracts of food contact polymers were analysed by GC-MS according to the Dutch testing system. Lists of the identified constituents in the extracts of polystyrene (PS), polypropylene (PP), polyethylene (PE), polyethylene terephthlate (PET) and polyvinylchloride (PVC) are given. More than 50 constituents were identified in the more than 1000 samples investigated. An estimation of the quantities of the extracted constituents has been made. In PVC the following compounds were present in relatively large quantities (10 times the height of the internal standards): diethylhexyladipate, dinonylphthalate, and other phthalates. However 68% of the extracts contained no peaks higher than the internal standards.
Efficient global biopolymer sampling with end-transfer configurational bias Monte Carlo
NASA Astrophysics Data System (ADS)
Arya, Gaurav; Schlick, Tamar
2007-01-01
We develop an "end-transfer configurational bias Monte Carlo" method for efficient thermodynamic sampling of complex biopolymers and assess its performance on a mesoscale model of chromatin (oligonucleosome) at different salt conditions compared to other Monte Carlo moves. Our method extends traditional configurational bias by deleting a repeating motif (monomer) from one end of the biopolymer and regrowing it at the opposite end using the standard Rosenbluth scheme. The method's sampling efficiency compared to local moves, pivot rotations, and standard configurational bias is assessed by parameters relating to translational, rotational, and internal degrees of freedom of the oligonucleosome. Our results show that the end-transfer method is superior in sampling every degree of freedom of the oligonucleosomes over other methods at high salt concentrations (weak electrostatics) but worse than the pivot rotations in terms of sampling internal and rotational sampling at low-to-moderate salt concentrations (strong electrostatics). Under all conditions investigated, however, the end-transfer method is several orders of magnitude more efficient than the standard configurational bias approach. This is because the characteristic sampling time of the innermost oligonucleosome motif scales quadratically with the length of the oligonucleosomes for the end-transfer method while it scales exponentially for the traditional configurational-bias method. Thus, the method we propose can significantly improve performance for global biomolecular applications, especially in condensed systems with weak nonbonded interactions and may be combined with local enhancements to improve local sampling.
Tsai, De-Cheng; Liu, Meng-Chieh; Lin, Yi-Reng; Huang, Mei-Fang; Liang, Shih-Shin
2016-04-15
Garlic (Allium sativum) is a long-cultivated plant that is widely utilized in cooking and has been employed as a medicine for over 4000 years. In this study, we fabricated standards and internal standards (ISs) for absolute quantification via reductive amination with isotopic formaldehydes. Garlic has four abundant organosulfur compounds (OSCs): S-allylcysteine, S-allylcysteinine sulfoxide, S-methylcysteine, and S-ethylcysteine are abundant in garlic. OSCs with primary amine groups were reacted with isotopic formaldehydes to synthesize ISs and standards. Cooked and uncooked garlic samples were compared, and we utilized tandem mass spectrometry equipped with a selective reaction monitoring technique to absolutely quantify the four organosulfur compounds. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pacquette, Lawrence H; Thompson, Joseph J; Malaviole, I; Zywicki, R; Woltjes, F; Ding, Y; Mittal, A; Ikeuchi, Y; Sadipiralla, B; Kimura, S; Veltman, H; Miura, A
2018-03-01
AOAC Final Action Official MethodSM 2015.06 "Minerals and Trace Elements in Milk, Milk Products, Infant Formula and Adult/Pediatric Nutritional Formula, ICP-MS Method" was collaboratively studied. Note that "milk, milk products" has now been added to the title of the Final Action method because whole milk and several dairy ingredients were successfully incorporated into the collaborative study for the purpose of developing an International Organization for Standardization/International Dairy Federation standard (ISO/DIS 21424; in progress). The method determines sodium, magnesium, phosphorus, potassium, calcium, iron, manganese, zinc, copper, chromium, molybdenum, and selenium by inductively coupled plasma (ICP)-MS after microwave digestion. Ten laboratories participated in the study, and data from five different model ICP-MS units were represented. Thirteen products, five placebo products, and six dairy samples were tested as blind duplicates in this study, along with a standard reference material, for a total 50 samples. The overall repeatability and reproducibility for all samples met Standard Method Performance Requirements put forth by the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals, with a few exceptions. Comparisons are made to ICP-atomic emission data from a collaborative study of AOAC Official Method 2011.14 carried out concurrently on these same samples.
Yarita, Takashi; Aoyagi, Yoshie; Otake, Takamitsu
2015-05-29
The impact of the matrix effect in GC-MS quantification of pesticides in food using the corresponding isotope-labeled internal standards was evaluated. A spike-and-recovery study of nine target pesticides was first conducted using paste samples of corn, green soybean, carrot, and pumpkin. The observed analytical values using isotope-labeled internal standards were more accurate for most target pesticides than that obtained using the external calibration method, but were still biased from the spiked concentrations when a matrix-free calibration solution was used for calibration. The respective calibration curves for each target pesticide were also prepared using matrix-free calibration solutions and matrix-matched calibration solutions with blank soybean extract. The intensity ratio of the peaks of most target pesticides to that of the corresponding isotope-labeled internal standards was influenced by the presence of the matrix in the calibration solution; therefore, the observed slope varied. The ratio was also influenced by the type of injection method (splitless or on-column). These results indicated that matrix-matching of the calibration solution is required for very accurate quantification, even if isotope-labeled internal standards were used for calibration. Copyright © 2015 Elsevier B.V. All rights reserved.
Internal quality assurance in a clinical virology laboratory. II. Internal quality control.
Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R
1995-01-01
AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475
International Agreement on Planetary Protection
NASA Technical Reports Server (NTRS)
2000-01-01
The maintenance of a NASA policy, is consistent with international agreements. The planetary protection policy management in OSS, with Field Center support. The advice from internal and external advisory groups (NRC, NAC/Planetary Protection Task Force). The technology research and standards development in bioload characterization. The technology research and development in bioload reduction/sterilization. This presentation focuses on: forward contamination - research on the potential for Earth life to exist on other bodies, improved strategies for planetary navigation and collision avoidance, and improved procedures for sterile spacecraft assembly, cleaning and/or sterilization; and backward contamination - development of sample transfer and container sealing technologies for Earth return, improvement in sample return landing target assessment and navigation strategy, planning for sample hazard determination requirements and procedures, safety certification, (liaison to NEO Program Office for compositional data on small bodies), facility planning for sample recovery system, quarantine, and long-term curation of 4 returned samples.
Hondrogiannis, Ellen M; Ehrlinger, Erin; Poplaski, Alyssa; Lisle, Meredith
2013-11-27
A total of 11 elements found in 25 vanilla samples from Uganda, Madagascar, Indonesia, and Papua New Guinea were measured by laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) for the purpose of collecting data that could be used to discriminate among the origins. Pellets were prepared of the samples, and elemental concentrations were obtained on the basis of external calibration curves created using five National Institute of Standards and Technology (NIST) standards and one Chinese standard with (13)C internal standardization. These curves were validated using NIST 1573a (tomato leaves) as a check standard. Discriminant analysis was used to successfully classify the vanilla samples by their origin. Our method illustrates the feasibility of using LA-ICP-TOF-MS with an external calibration curve for high-throughput screening of spice screening analysis.
[On the way to national reference system of laboratory medicine].
Muravskaia, N P; Men'shikov, V V
2014-10-01
The application of standard samples and reference techniques of implementation of measurements is needed for a valid support of reliability of analyses applied in clinical diagnostic laboratories. They play role of landmarks under metrologic monitoring, calibration of devices and control of quality of results. The article presents analysis of shortcomings interfering with formation of national reference system in Russia harmonized with possibilities provided by international organizations. Among them are the joint Committee on metrologic monitoring in laboratory medicine under the auspices of the International Bureau of Weights and Measures, the International Federation of clinical chemistry and laboratory medicine, etc. The results of the recent development of national normative documents, standard samples and techniques assisted by the authors of article are considered. They are the first steps to organization of national reference system which would comprise all range of modern analytical technologies of laboratory medicine. The national and international measures are proposed to enhance the promptest resolving of task of organization of national reference system for laboratory medicine in the interests of increasing of effectiveness of medical care to citizen of Russia.
NASA Astrophysics Data System (ADS)
Mandic, M.; Stöbener, N.; Smajgl, D.
2017-12-01
For many decades different instrumental methods involving generations of the isotope ratio mass spectrometers with different periphery units for sample preparation, have provided scientifically required high precision, and high throughput of samples for varies application - from geological and hydrological to food and forensic. With this work we introduce automated measurement of δ13C and δ18O from solid carbonate samples, DIC and δ18O of water. We have demonstrated usage of a Thermo Scientific™ Delta Ray™ IRIS with URI Connect on certified reference materials and confirmed the high achievable accuracy and a precision better then <0.1‰ for both δ13C and δ18O, in the laboratory or the field with same precision and throughput of samples. With equilibration method for determination of δ18O in water samples, which we present in this work, achieved repeatability and accuracy are 0.12‰ and 0.68‰ respectively, which fulfill requirements of regulatory methods. The preparation of the samples for carbonate and DIC analysis on the Delta Ray IRIS with URI Connect is similar to the previously mentioned Gas Bench II methods. Samples are put into vials and phosphoric acid is added. The resulting sample-acid chemical reaction releases CO2 gas, which is then introduced into the Delta Ray IRIS via the Variable Volume. Three international standards of carbonate materials (NBS-18, NBS-19 and IAEA-CO-1) were analyzed. NBS-18 and NBS-19 were used as standards for calibration, and IAEA-CO-1 was treated as unknown. For water sample analysis equilibration method with 1% of CO2 in dry air was used. Test measurements and conformation of precision and accuracy of method determination δ18O in water samples were done with three lab standards, namely ANST, OCEAN 2 and HBW. All laboratory standards were previously calibrated with international reference material VSMOW2 and SLAP2 to assure accuracy of the isotopic values. The Principle of Identical Treatment was applied in sample and standard preparation, in measurement procedure, as well as in the evaluation of the results.
Ewart, Kyle M; Frankham, Greta J; McEwing, Ross; Webster, Lucy M I; Ciavaglia, Sherryn A; Linacre, Adrian M T; The, Dang Tat; Ovouthan, Kanitia; Johnson, Rebecca N
2018-01-01
Rhinoceros (rhino) numbers have dwindled substantially over the past century. As a result, three of the five species are now considered to be critically endangered, one species is vulnerable and one species is near-threatened. Poaching has increased dramatically over the past decade due to a growing demand for rhino horn products, primarily in Asia. Improved wildlife forensic techniques, such as validated tests for species identification of seized horns, are critical to aid current enforcement and prosecution efforts and provide a deterrent to future rhino horn trafficking. Here, we present an internationally standardized species identification test based on a 230 base pair cytochrome-b region. This test improves on previous nested PCR protocols and can be used for the discrimination of samples with <20pg of template DNA, thus suitable for DNA extracted from horn products. The assay was designed to amplify water buffalo samples, a common 'rhino horn' substitute, but to exclude human DNA, a common contaminant. Phylogenetic analyses using this partial cytochrome-b region resolved the five extant rhino species. Testing successfully returned a sequence and correct identification for all of the known rhino horn samples and vouchered rhino samples from museum and zoo collections, and provided species level identification for 47 out of 52 unknown samples from seizures. Validation and standardization was carried out across five different laboratories, in four different countries, demonstrating it to be an effective and reproducible test, robust to inter laboratory variation in equipment and consumables (such as PCR reagents). This is one of the first species identification tests to be internationally standardized to produce data for evidential proceedings and the first published validated test for rhinos, one of the flagship species groups of the illegal wildlife trade and for which forensic tools are urgently required. This study serves as a model for how species identification tests should be standardized and disseminated for wildlife forensic testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Bakaikina, Nadezhda V; Kenessov, Bulat; Ul'yanovskii, Nikolay V; Kosyakov, Dmitry S
2018-07-01
Determination of transformation products (TPs) of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in soil is highly important for environmental impact assessment of the launches of heavy space rockets from Kazakhstan, Russia, China and India. The method based on headspace solid-phase microextraction (HS SPME) and gas chromatography-mass spectrometry is advantageous over other known methods due to greater simplicity and cost efficiency. However, accurate quantification of these analytes using HS SPME is limited by the matrix effect. In this research, we proposed using internal standard and standard addition calibrations to achieve proper combination of accuracies of the quantification of key TPs of UDMH and cost efficiency. 1-Trideuteromethyl-1H-1,2,4-triazole (MTA-d3) was used as the internal standard. Internal standard calibration allowed controlling matrix effects during quantification of 1-methyl-1H-1,2,4-triazole (MTA), N,N-dimethylformamide (DMF), and N-nitrosodimethylamine (NDMA) in soils with humus content < 1%. Using SPME at 60 °C for 15 min by 65 µm Carboxen/polydimethylsiloxane fiber, recoveries of MTA, DMF and NDMA for sandy and loamy soil samples were 91-117, 85-123 and 64-132%, respectively. For improving the method accuracy and widening the range of analytes, standard addition and its combination with internal standard calibration were tested and compared on real soil samples. The combined calibration approach provided greatest accuracies for NDMA, DMF, N-methylformamide, formamide, 1H-pyrazole, 3-methyl-1H-pyrazole and 1H-pyrazole. For determination of 1-formyl-2,2-dimethylhydrazine, 3,5-dimethylpyrazole, 2-ethyl-1H-imidazole, 1H-imidazole, 1H-1,2,4-triazole, pyrazines and pyridines, standard addition calibration is more suitable. However, the proposed approach and collected data allow using both approaches simultaneously. Copyright © 2018 Elsevier B.V. All rights reserved.
Granja, Rodrigo H M M; Salerno, Alessandro G; de Lima, Andreia C; Montalvo, Cynthia; Reche, Karine V G; Giannotti, Fabio M; Wanschel, Amarylis C B A
2014-01-01
Boldenone, an androgenic steroid, is forbidden for use in meat production in most countries worldwide. Residues of this drug in food present a potential risk to consumers. A sensitive LC/MS/MS method for analysis of 17β-boldenone using boldenone-d3 as an internal standard was developed. An enzymatic hydrolysis and extraction using ethyl acetate, methanol, and hexane were performed in the sample preparation. Parameters such as decision limit (CCα), detection capability (CCβ), precision, recovery, and ruggedness were evaluated according to the Brazilian Regulation 24/2009 (equivalent to European Union Decision 2002/657/EC) and International Organization for Standardization/International Electrotechnical Commission 17025:2005. CCα and CCβ were determined to be 0.17 and 0.29 μg/kg, respectively. Average recoveries from bovine liver samples fortified with 1, 1.5, and 2 μg/kg were around 100%. A complete statistical analysis was performed on the results obtained, including an estimation of the method uncertainty. The method is considered robust after being subjected to day-to-day analytical variations and has been used as a standard method in Brazil to report boldenone levels in bovine liver.
Peng, G W; Sood, V K; Rykert, U M
1985-03-01
Bromadoline and its two N-demethylated metabolites were extracted into ether:butyl chloride after the addition of internal standard and basification of the various biological fluids (blood, plasma, serum, and urine). These compounds were then extracted into dilute phosphoric acid from the organic phase and separated on a reversed-phase chromatographic system using a mobile phase containing acetonitrile and a buffer of 1,4-dimethylpiperazine and perchloric acid. The overall absolute extraction recoveries of these compounds were approximately 50-80%. The background interferences from the biological fluids were negligible and allowed quantitative determination of bromadoline and the metabolites at levels as low as 2-5 ng/mL. At mobile phase flow rate of 1 mL/min, the sample components and the internal standard were eluted at the retention times within approximately 7-12 min. The drug- and metabolite-to-internal standard peak height ratios showed excellent linear relationships with their corresponding concentrations. The analytical method showed satisfactory within- and between-run assay precision and accuracy, and has been utilized in the simultaneous determination of bromadoline and its two N-demethylated metabolites in biological fluids collected from humans and from dogs after administration of bromadoline maleate.
Unice, Kenneth M.; Kreider, Marisa L.; Panko, Julie M.
2012-01-01
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories. PMID:23202830
Sobrado, Laura Alonso; Freije-Carrelo, Laura; Moldovan, Mariella; Encinar, Jorge Ruiz; Alonso, J Ignacio García
2016-07-29
GC-FID has been effectively used as a universal quantification technique for volatile organic compounds for a long time. In most cases, the use of the ECN allows for quantification by GC-FID without external calibration using only the response of a single internal standard. In this paper we compare the performance characteristics of GC-FID with those of post-column (13)C Isotope Dilution GC-Combustion-MS for the absolute quantification of organic compounds without the need for individual standards. For this comparison we have selected the quantification of FAMEs in biodiesel. The selection of the right internal standard was critical for GC-FID even when ECN were considered. On the other hand, the nature of the internal standard was not relevant when GC-Combustion-MS was employed. The proposed method was validated with the analysis of the certified reference material SRM 2772 and comparative data was obtained on real biodiesel samples. The analysis of the SRM 2772 biodiesel provided recoveries in the range 100.6-103.5% and 96.4-103.6% for GC-combustion-MS and GC-FID, respectively. The detection limit for GC-combustion-MS was found to be 4.2ng compound/g of injected sample. In conclusion, the quantitative performance of GC-Combustion-MS compared satisfactorily with that of GC-FID constituting a viable alternative for the quantification of organic compounds without the need for individual standards. Copyright © 2016 Elsevier B.V. All rights reserved.
Sanders, Peter; Ernste-Nota, Veronica; Visser, Klaas; van Soest, Jeroen; Brunt, Kommer
2017-09-01
A method using high-performance anion-exchange chromatography (HPAEC) with a pulsed amperometric detector (PAD) for the determination of mono- and disaccharides is described. The method was accepted by the International Dairy Federation and the Internal Organization for Standardization as a new work item for the determination of sugars in dairy matrixes, and the Milk and Milk Products technical committee of ISO/TC 34/SC 5 accepted the topic "Milk and milk products - Determination of the sugar contents - High-performance anion-exchange chromatographic method (HPAEC-PAD)" as a new work item. The proposed method consists of an aqueous ethanol extraction of the sugars in the dairy sample, followed by clarification with Carrez I and II reagents. The clarified filtrate is diluted and then directly introduced in the HPAEC-PAD system for quantification of the sugars. A single-laboratory validation of the proposed method has been scheduled for spring 2017.
New method for determination of ten pesticides in human blood.
García-Repetto, R; Giménez, M P; Repetto, M
2001-01-01
An analytical method was developed for precise identification and quantitation of 10 pesticides in human blood. The pesticides studied, which have appeared frequently in actual cases, were endosulfan, lindane, parathion, ethyl-azinphos, diazinon, malathion, alachlor, tetradifon, fenthion and dicofol (o-p' and p-p' isomers). The current method replaces an earlier method which involved liquid-liquid extraction with a mixture of n-hexane-benzene (1 + 1). The extraction is performed by solid-phase extraction, with C18 cartridges and 2 internal standards, perthane and triphenylphosphate. Eluates were analyzed by gas chromatography (GC) with nitrogen-phosphorus and electrochemical detectors. Results were confirmed by GC-mass spectrometry in the electron impact mode. Blood blank samples spiked with 2 standard mixtures and an internal standard were used for quantitation. Mean recoveries ranged from 71.83 to 97.10%. Detection and quantitation limits are reported for each pesticide. Examples are provided to show the application of the present method to actual samples.
Emerging developments in the standardized chemical characterization of indoor air quality.
Nehr, Sascha; Hösen, Elisabeth; Tanabe, Shin-Ichi
2017-01-01
Despite the fact that the special characteristics of indoor air pollution make closed environments quite different from outdoor environments, the conceptual ideas for assessing air quality indoors and outdoors are similar. Therefore, the elaboration of International Standards for air quality characterization in view of controlling indoor air quality should resort to this common basis. In this short review we describe the possibilities of standardization of tools dedicated to indoor air quality characterization with a focus on the tools permitting to study the indoor air chemistry. The link between indoor exposure and health as well as the critical processes driving the indoor air quality are introduced. Available International Standards for the assessment of indoor air quality are depicted. The standards comprise requirements for the sampling on site, the analytical procedures, and the determination of material emissions. To date, these standardized procedures assure that indoor air, settled dust and material samples are analyzed in a comparable manner. However, existing International Standards exclusively specify conventional, event-driven target-screening using discontinuous measurement methods for long-lived pollutants. Therefore, this review draws a parallel between physico-chemical processes in indoor and outdoor environments. The achievements in atmospheric sciences also improve our understanding of indoor environments. The community of atmospheric scientists can be both ideal and supporter for researchers in the area of indoor air quality characterization. This short review concludes with propositions for future standardization activities for the chemical characterization of indoor air quality. Future standardization efforts should focus on: (i) the elaboration of standardized measurement methods and measurement strategies for online monitoring of long-lived and short-lived pollutants, (ii) the assessment of the potential and the limitations of non-target screening, (iii) the paradigm shift from event-driven investigations to systematic approaches to characterize indoor environments, and (iv) the development of tools for policy implementation. Copyright © 2016 Elsevier Ltd. All rights reserved.
de Babos, Diego Victor; Bechlin, Marcos André; Barros, Ariane Isis; Ferreira, Edilene Cristina; Gomes Neto, José Anchieta; de Oliveira, Silvana Ruella
2016-05-15
A new method is proposed for the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS), employing direct solid sample analysis (DSS) and internal standardization (IS). Cobalt was used as internal standard to minimize matrix effects during Ni determinations, enabling the use of aqueous standards for calibration. Correlation coefficients for the calibration curves were typically better than 0.9937. The performance of the method was checked by analysis of six plant certified reference materials, and the results for Mo and Ni were in agreement with the certified values (95% confidence level, t-test). Analysis was made of different types of plant materials used as renewable sources of energy, including sugarcane leaves, banana tree fiber, soybean straw, coffee pods, orange bagasse, peanut hulls, and sugarcane bagasse. The concentrations found for Mo and Ni ranged from 0.08 to 0.63 ng mg(-1) and from 0.41 to 6.92 ng mg(-1), respectively. Precision (RSD) varied from 2.1% to 11% for Mo and from 3.7% to 10% for Ni. Limits of quantification of 0.055 and 0.074 ng were obtained for Mo and Ni, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Zainol, Murizal; Stoute, Julia; Almeida, Gabriela M.; Rapp, Alexander; Bowman, Karen J.; Jones, George D. D.
2009-01-01
The Comet assay (CA) is a sensitive/simple measure of genotoxicity. However, many features of CA contribute variability. To minimize these, we have introduced internal standard materials consisting of ‘reference’ cells which have their DNA substituted with BrdU. Using a fluorescent anti-BrdU antibody, plus an additional barrier filter, comets derived from these cells could be readily distinguished from the ‘test’-cell comets, present in the same gel. In experiments to evaluate the reference cell comets as external and internal standards, the reference and test cells were present in separate gels on the same slide or mixed together in the same gel, respectively, before their co-exposure to X-irradiation. Using the reference cell comets as internal standards led to substantial reductions in the coefficient of variation (CoV) for intra- and inter-experimental measures of comet formation and DNA damage repair; only minor reductions in CoV were noted when the reference and test cell comets were in separate gels. These studies indicate that differences between individual gels appreciably contribute to CA variation. Further studies using the reference cells as internal standards allowed greater significance to be obtained between groups of replicate samples. Ultimately, we anticipate that development will deliver robust quality assurance materials for CA. PMID:19828597
Lee, Hun Joo; Han, Eunyoung; Lee, Jaesin; Chung, Heesun; Min, Sung-Gi
2016-11-01
The aim of this study is to improve resolution of impurity peaks using a newly devised normalization algorithm for multi-internal standards (ISs) and to describe a visual peak selection system (VPSS) for efficient support of impurity profiling. Drug trafficking routes, location of manufacture, or synthetic route can be identified from impurities in seized drugs. In the analysis of impurities, different chromatogram profiles are obtained from gas chromatography and used to examine similarities between drug samples. The data processing method using relative retention time (RRT) calculated by a single internal standard is not preferred when many internal standards are used and many chromatographic peaks present because of the risk of overlapping between peaks and difficulty in classifying impurities. In this study, impurities in methamphetamine (MA) were extracted by liquid-liquid extraction (LLE) method using ethylacetate containing 4 internal standards and analyzed by gas chromatography-flame ionization detection (GC-FID). The newly developed VPSS consists of an input module, a conversion module, and a detection module. The input module imports chromatograms collected from GC and performs preprocessing, which is converted with a normalization algorithm in the conversion module, and finally the detection module detects the impurities in MA samples using a visualized zoning user interface. The normalization algorithm in the conversion module was used to convert the raw data from GC-FID. The VPSS with the built-in normalization algorithm can effectively detect different impurities in samples even in complex matrices and has high resolution keeping the time sequence of chromatographic peaks the same as that of the RRT method. The system can widen a full range of chromatograms so that the peaks of impurities were better aligned for easy separation and classification. The resolution, accuracy, and speed of impurity profiling showed remarkable improvement. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zhou, Jinhui; Xue, Xiaofeng; Li, Yi; Zhang, Jinzhen; Zhao, Jing
2007-01-01
An optimized reversed-phase high-performance liquid chromatography method was developed to detect the trans-10-hydroxy-2-decenoic acid (10-HDA) content in royal jelly cream and lyophilized powder. The sample was extracted using absolute ethanol. Chromatographic separation of 10-HDA and methyl 4-hydroxybenzoate as the internal standard was performed on a Nova-pak C18 column. The average recoveries were 95.0-99.2% (n = 5) with relative standard deviation (RSD) values of 1.3-2.1% for royal jelly cream and 98.0-100.0% (n = 5) with RSD values of 1.6-3.0% for lyophilized powder, respectively. The limits of detection and quantitation were 0.5 and 1.5 mg/kg, respectively, for both royal jelly cream and lyophilized powder. The method was validated for the determination of practical royal jelly products. The concentration of 10-HDA ranged from 1.26 to 2.21% for pure royal jelly cream samples and 3.01 to 6.19% for royal jelly lyophilized powder samples. For 30 royal jelly products, the 10-HDA content varied from not detectable to 0.98%.
Farenc, C; Enjalbal, C; Sanchez, P; Bressolle, F; Audran, M; Martinez, J; Aubagnac, J L
2001-02-23
Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was used for the quantification of the neuromuscular blocking agent rocuronium in human plasma. Verapamil was used as internal standard. The samples were subjected to a dichloromethane liquid-liquid extraction after ion pairing of the positively charged ammonium compound with iodide prior to LC-MS. Optimized conditions involved separation on a Symmetry Shield RP-18 column (50 x 2.1 mm, 3.5 microm) using a 15-min gradient from 10 to 90% acetonitrile in water containing 0.1% trifluoroacetic acid at 250 microl/min. Linear detector responses for standards were observed from 25 to 2,000 ng/ml. The extraction recovery averaged 59% for rocuronium and 83% for the internal standard. The limit of quantification (LOQ), using 500 microl of plasma, was 25 ng/ml. Precision ranged from 1.3 to 19% (LOQ), and accuracy was between 92 and 112%. In plasma samples, at 20 and 4 degrees C, rocuronium was stable at physiological pH for 4 h; frozen at -30 degrees C it was stable for at least 75 days. The method was found suitable for the analysis of samples collected during pharmacokinetic investigations in humans.
2018-01-01
This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (
ERIC Educational Resources Information Center
Liu, Xiufeng
2006-01-01
Using the US national sample from the 1995 Third International Mathematics and Science Study (TIMSS), this study examined students' competence levels in understanding the matter concept at grades 3, 4, 7, 8 and high school graduation, and compared them to the expectations in the US national science education standards. It was found that…
Modeling Payload Stowage Impacts on Fire Risks On-Board the International Space Station
NASA Technical Reports Server (NTRS)
Anton, Kellie e.; Brown, Patrick F.
2010-01-01
The purpose of this presentation is to determine the risks of fire on-board the ISS due to non-standard stowage. ISS stowage is constantly being reexamined for optimality. Non-standard stowage involves stowing items outside of rack drawers, and fire risk is a key concern and is heavily mitigated. A Methodology is needed to account for fire risk due to non-standard stowage to capture the risk. The contents include: 1) Fire Risk Background; 2) General Assumptions; 3) Modeling Techniques; 4) Event Sequence Diagram (ESD); 5) Qualitative Fire Analysis; 6) Sample Qualitative Results for Fire Risk; 7) Qualitative Stowage Analysis; 8) Sample Qualitative Results for Non-Standard Stowage; and 9) Quantitative Analysis Basic Event Data.
UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water.
Clauson-Kaas, Frederik; Hansen, Hans Christian Bruun; Strobel, Bjarne W
2016-11-01
The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by 1 H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.
Siebenhaar, Markus; Küllmer, Kai; Fernandes, Nuno Miguel de Barros; Hüllen, Volker; Hopf, Carsten
2015-09-01
Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitating sample spreading with a cellulose layer for addition of isotope-labeled salicylic acid as internal standard and a filter paper for analysis of the standard-containing sample by DESI-MS. Using this setup, we developed a quantification method for salicylic acid from whole blood with a validated linear curve range from 10 to 2000 mg/L, a relative standard deviation (RSD%) ≤14%, and determination coefficients of 0.997. The limit of detection (LOD) was 8 mg/L and the lower limit of quantification (LLOQ) was 10 mg/L. Recovery rates in method verification by LC-MS/MS were 97 to 101% for blinded samples. Most importantly, a study in healthy volunteers after administration of a single dose of Aspirin provides evidence to suggest that the three-layer setup may enable individual pharmacokinetic and endpoint testing following blood collection by finger pricking by patients at home. Taken together, our data suggests that DBS-based quantification of drugs by DESI-MS on pre-manufactured three-layer cartridges may be a promising approach for future near-patient therapeutic drug monitoring.
Pesticide residues in orange fruit from citrus orchards in Nuevo Leon State, Mexico.
Suárez-Jacobo, Angela; Alcantar-Rosales, Victor Manuel; Alonso-Segura, Diana; Heras-Ramírez, Maria; Elizarragaz-De La Rosa, Dalau; Lugo-Melchor, Ofelia; Gaspar-Ramirez, Octavio
2017-09-01
Some international organisations established maximum residue limits (MRLs) in food to protect human health. Mexico lacks regulations in this matter, affecting national and international trade from agroindustry. The aim of this study was to diagnose pesticide residues in oranges from Nuevo Leon, México, in citrus orchards. In May 2014, 100 orange fruit samples were taken randomly from orchards and subjected to analysis for 93 pesticides at residual level by GC/QQQ-MS and LCQ-TOF-MS. Results showed the presence of 15 pesticide residues in the samples. The comparison of the residual levels of pesticides found in orange samples among the MRLs allowed by USA, EU and Japanese regulations demonstrated that all samples were below MRLs issued by USA and Japan. Some orange samples were above MRLs issued by the EU. This provides a basis to establish strategies in order to satisfy International Standards to protect human health and encourage Food Safety in Mexico.
Ramsingh, Brigit
2014-07-01
Following the Second World War, the Food and Agriculture Organization (FAO) and the World Health Organization (WHO) teamed up to construct an International Codex Alimentarius (or 'food code') which emerged in 1963. The Codex Committee on Food Hygiene (CCFH) was charged with the task of developing microbial hygiene standards, although it found itself embroiled in debate with the WHO over the nature these standards should take. The WHO was increasingly relying upon the input of biometricians and especially the International Commission on Microbial Specifications for Foods (ICMSF) which had developed statistical sampling plans for determining the microbial counts in the final end products. The CCFH, however, was initially more focused on a qualitative approach which looked at the entire food production system and developed codes of practice as well as more descriptive end-product specifications which the WHO argued were 'not scientifically correct'. Drawing upon historical archival material (correspondence and reports) from the WHO and FAO, this article examines this debate over microbial hygiene standards and suggests that there are many lessons from history which could shed light upon current debates and efforts in international food safety management systems and approaches.
NASA Astrophysics Data System (ADS)
Lizana, A.; Foldyna, M.; Stchakovsky, M.; Georges, B.; Nicolas, D.; Garcia-Caurel, E.
2013-03-01
High sensitivity of spectroscopic ellipsometry and reflectometry for the characterization of thin films can strongly decrease when layers, typically metals, absorb a significant fraction of the light. In this paper, we propose a solution to overcome this drawback using total internal reflection ellipsometry (TIRE) and exciting a surface longitudinal wave: a plasmon-polariton. As in the attenuated total reflectance technique, TIRE exploits a minimum in the intensity of reflected transversal magnetic (TM) polarized light and enhances the sensitivity of standard methods to thicknesses of absorbing films. Samples under study were stacks of three films, ZnO : Al/Ag/ZnO : Al, deposited on glass substrates. The thickness of the silver layer varied from sample to sample. We performed measurements with a UV-visible phase-modulated ellipsometer, an IR Mueller ellipsometer and a UV-NIR reflectometer. We used the variance-covariance formalism to evaluate the sensitivity of the ellipsometric data to different parameters of the optical model. Results have shown that using TIRE doubled the sensitivity to the silver layer thickness when compared with the standard ellipsometry. Moreover, the thickness of the ZnO : Al layer below the silver layer can be reliably quantified, unlike for the fit of the standard ellipsometry data, which is limited by the absorption of the silver layer.
Standardization of Brief Inventory of Social Support Exchange Network (BISSEN) in Japan.
Aiba, Miyuki; Tachikawa, Hirokazu; Fukuoka, Yoshiharu; Lebowitz, Adam; Shiratori, Yuki; Doi, Nagafumi; Matsui, Yutaka
2017-07-01
This study describes the Brief Inventory of Social Support Exchange Network (BISSEN) as a standardized brief inventory measuring various aspects of social support. We confirmed the reliability and validity for function and direction of support and standardized the BISSEN. For Sample 1, a stratified random sampling method was used to select 5200 residents in Japan. We conducted mail surveys and responses were retrieved from 2274 participants (collection rate 43.7%). Participants completed a questionnaire packet that included BISSEN, suicidal ideation, depression, support seeking, and Multidimensional Scale of Perceived Social Support (MSPSS). Sample 2 surveys for test-retest reliability were conducted on 23 residents at approximately two-week intervals. Participants were asked about gender, age, and BISSEN. First, we assessed the internal consistency, test-retest reliability, construct, convergent, and concurrent validity. McDonald's omega (.73-.92) and test-retest correlations (.78-.85) demonstrated adequate internal consistency and test-retest reliability. Depression, support seeking, and MSPSS were significantly correlated with all scores of BISSEN. The non-suicidal ideation group had significantly more support compared to the suicidal ideation group. Therefore, function and direction of support in BISSEN had sufficient reliability and validity. Next, we standardized BISSEN using Z-scores and percentile rank with respect to each 12 norm groups by age and gender. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colle, R.; Unterweger, M.P.; Hutchinson, J.M.R.
1996-01-01
As part of an international measurement intercomparison of instruments used to measure atmospheric {sup 222}Rn, four participating laboratories made nearly simultaneous measurements of {sup 222}Rn activity concentration in commonly sampled, ambient air over approximately a 2 week period, and three of these four laboratories participated in the measurement comparison of 14 introduced samples with known, but undisclosed (blind) {sup 222}Rn activity concentration. The exercise was conducted in Bermuda in October 1991. The {sup 222}Rn activity concentrations in ambient Bermudian air over the course of the intercomparison ranged from a few hundredths of a Bq {center_dot} m{sup {minus}3} to about 2more » Bq {center_dot} m{sup {minus}3}, while the standardized sample additions covered a range from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3}. The overall uncertainty in the latter concentrations was in the general range of 10%, approximating a 3 standard deviation uncertainty interval. The results of the intercomparison indicated that two of the laboratories were within very good agreement with the standard additions, and almost within expected statistical variations. These same two laboratories, however, at lower ambient concentrations, exhibited a systematic difference with an averaged offset of roughly 0.3 Bq {center_dot} m{sup {minus}3}. The third laboratory participating in the measurement of standardized sample additions was systematically low by about 65% to 70%, with respect to the standard addition which was also confirmed in their ambient air concentration measurements. The fourth laboratory, participating in only the ambient measurement part of the intercomparison, was also systematically low by at least 40% with respect to the first two laboratories.« less
Go, Young-Mi; Walker, Douglas I; Liang, Yongliang; Uppal, Karan; Soltow, Quinlyn A; Tran, ViLinh; Strobel, Frederick; Quyyumi, Arshed A; Ziegler, Thomas R; Pennell, Kurt D; Miller, Gary W; Jones, Dean P
2015-12-01
The exposome is the cumulative measure of environmental influences and associated biological responses throughout the lifespan, including exposures from the environment, diet, behavior, and endogenous processes. A major challenge for exposome research lies in the development of robust and affordable analytic procedures to measure the broad range of exposures and associated biologic impacts occurring over a lifetime. Biomonitoring is an established approach to evaluate internal body burden of environmental exposures, but use of biomonitoring for exposome research is often limited by the high costs associated with quantification of individual chemicals. High-resolution metabolomics (HRM) uses ultra-high resolution mass spectrometry with minimal sample preparation to support high-throughput relative quantification of thousands of environmental, dietary, and microbial chemicals. HRM also measures metabolites in most endogenous metabolic pathways, thereby providing simultaneous measurement of biologic responses to environmental exposures. The present research examined quantification strategies to enhance the usefulness of HRM data for cumulative exposome research. The results provide a simple reference standardization protocol in which individual chemical concentrations in unknown samples are estimated by comparison to a concurrently analyzed, pooled reference sample with known chemical concentrations. The approach was tested using blinded analyses of amino acids in human samples and was found to be comparable to independent laboratory results based on surrogate standardization or internal standardization. Quantification was reproducible over a 13-month period and extrapolated to thousands of chemicals. The results show that reference standardization protocol provides an effective strategy that will enhance data collection for cumulative exposome research. In principle, the approach can be extended to other types of mass spectrometry and other analytical methods. © The Author 2015. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Go, Young-Mi; Walker, Douglas I.; Liang, Yongliang; Uppal, Karan; Soltow, Quinlyn A.; Tran, ViLinh; Strobel, Frederick; Quyyumi, Arshed A.; Ziegler, Thomas R.; Pennell, Kurt D.; Miller, Gary W.; Jones, Dean P.
2015-01-01
The exposome is the cumulative measure of environmental influences and associated biological responses throughout the lifespan, including exposures from the environment, diet, behavior, and endogenous processes. A major challenge for exposome research lies in the development of robust and affordable analytic procedures to measure the broad range of exposures and associated biologic impacts occurring over a lifetime. Biomonitoring is an established approach to evaluate internal body burden of environmental exposures, but use of biomonitoring for exposome research is often limited by the high costs associated with quantification of individual chemicals. High-resolution metabolomics (HRM) uses ultra-high resolution mass spectrometry with minimal sample preparation to support high-throughput relative quantification of thousands of environmental, dietary, and microbial chemicals. HRM also measures metabolites in most endogenous metabolic pathways, thereby providing simultaneous measurement of biologic responses to environmental exposures. The present research examined quantification strategies to enhance the usefulness of HRM data for cumulative exposome research. The results provide a simple reference standardization protocol in which individual chemical concentrations in unknown samples are estimated by comparison to a concurrently analyzed, pooled reference sample with known chemical concentrations. The approach was tested using blinded analyses of amino acids in human samples and was found to be comparable to independent laboratory results based on surrogate standardization or internal standardization. Quantification was reproducible over a 13-month period and extrapolated to thousands of chemicals. The results show that reference standardization protocol provides an effective strategy that will enhance data collection for cumulative exposome research. In principle, the approach can be extended to other types of mass spectrometry and other analytical methods. PMID:26358001
2013-03-01
ratio ranges obtained for the six standards. Twelve samples were analyzed to demonstrate the efficiency of the extraction procedure. Drug and internal...frozen (−70 ◦C). Refrigerated samples were tested after 2 months of storage ; frozen samples were tested for up to 1 year from stor- age date. The...freeze–thaw stability was evaluated by analyzing three subject samples with known drug concentrations and two quality control samples at concentrations
How to measure the internationality of scientific publications.
Buela-Casal, Gualberto; Zych, Izabela
2012-01-01
Although the term "internationality" has never been defined by consensus, it is commonly used as a synonym of quality. Even though its meaning has never been established, internationality is frequently used to evaluate scientists, publications, or universities in many different countries. The present investigation is based on the opinion about the meaning of the concept "internationality" of the members of scientific community, represented by a broad sample of 16,056 scientists from 109 countries working in all the fields of knowledge defined by UNESCO. The sample was randomly selected from the Web of Science database from the scientists who have published at least one article in one of the journals indexed by the database. A questionnaire based on eleven criteria was designed for the purpose of the study. As a result, the first measure of internationality has been obtained. The most important criteria of internationality are: the publication language, online access, and international publication standards. There are significant differences among geographic zones and fields of knowledge.
Peer, Cody J; Shakleya, Diaa M; Younis, Islam R; Kraner, James C; Callery, Patrick S
2007-10-01
A rapid mass spectrometric method was developed for the identification of fentanyl and its major hepatic metabolite norfentanyl in postmortem urine of six drug-overdose victims involving fentanyl use. To reduce matrix effects or ion suppression, sample preparation consisted of centrifugation and solid-phase extraction. Deuterium-labeled internal standards ((2)H(5)-fentanyl and (2)H(5)-norfentanyl) were used to compensate for instrument variation in signal, analyte recovery during sample preparation, and ion suppression. Structural information for fentanyl and norfentanyl were collected using mass spectrometry (MS) with electrospray ionization (ESI) operated in the positive ion mode. Fentanyl (m/z 337) was found in each of the six overdose cases by the appearance of the MS-MS daughter ion on both an ion trap and a triple-quadrupole MS resulting from the fragmentation pathway of fentanyl (m/z 337 --> 188). Norfentanyl was detected in all six cases by the appearance of the MH(+) ion, m/z 233, with a single-quadrupole MS and confirmed in an ion trap MS. Ion suppression, as determined by the comparison of ion intensities from spiked samples in water with postmortem urine from the cases, ranged from 18% to 98% in three ESI sources. The use of stable isotope-labeled internal standards obviates sample preparation because ratios of analyte/internal standard remain constant in the presence of extensive matrix effects. This MS method provided sufficient sensitivity and selectivity for the rapid identification of fentanyl and norfentanyl in urine at levels >/= 10 ng/mL without prior analyte resolution by chromatography and with a total analysis time of less than 1 h.
Towards a unified sampling terminology: clarifying misperceptions.
Thiex, Nancy; Paoletii, Claudia; Esbensen, Kim H
2015-01-01
International acceptance of data is a much-desired wish in many sectors to ensure equal standards for valid information and data exchange, facilitate trade, support food safety regulation, and promote reliable communication among all parties involved. However, this cannot be accomplished without a harmonized approach to sampling and a joint approach to assess the practical sampling protocols used. Harmonization based on a nonrepresentative protocol, or on a restricted terminology tradition forced upon other sectors would negate any constructive outcome. An international discussion on a harmonized approach to sampling is severely hampered by a plethora of divergent sampling definitions and terms. Different meanings for the same term are frequently used by the different sectors, and even within one specific sector. In other cases, different terms are used for the same concept. Before efforts to harmonize can be attempted, it is essential that all stakeholders can at least communicate effectively in this context. Therefore, a clear understanding of the main vocabularies becomes an essential prerequisite. As a first step, commonalities and dichotomies in terminology are here brought to attention by providing a comparative summary of the. terminology as defined by the Theory of Sampling {TOS) and those in current use by the International Organization for Standardization, the World Health Organization, the Food and Agriculture Organization Codex Alimentarius, and the U.S. Food and Drug Administration. Terms having contradictory meaning to the TOS are emphasized. To the degree possible, we present a successful resolution of some of the most important issues outlined, sufficient to support the objectives of the present Special Section.
The Paris System for Reporting Urinary Cytology: The Quest to Develop a Standardized Terminology.
Barkan, Güliz A; Wojcik, Eva M; Nayar, Ritu; Savic-Prince, Spasenija; Quek, Marcus L; Kurtycz, Daniel F I; Rosenthal, Dorothy L
2016-07-01
The main purpose of urine cytology is to detect high-grade urothelial carcinoma. With this principle in mind, The Paris System (TPS) Working Group, composed of cytopathologists, surgical pathologists, and urologists, has proposed and published a standardized reporting system that includes specific diagnostic categories and cytomorphologic criteria for the reliable diagnosis of high-grade urothelial carcinoma. This paper outlines the essential elements of TPS and the process that led to the formation and rationale of the reporting system. TPS Working Group, organized at the 2013 International Congress of Cytology, conceived a standardized platform on which to base cytologic interpretation of urine samples. The widespread dissemination of this approach to cytologic examination and reporting of urologic samples and the scheme's universal acceptance by pathologists and urologists is critical for its success. For urologists, understanding the diagnostic criteria, their clinical implications, and limitations of TPS is essential if they are to utilize urine cytology and noninvasive ancillary tests in a thoughtful and practical manner. This is the first international/inclusive attempt at standardizing urinary cytology. The success of TPS will depend on the pathology and urology communities working collectively to improve this seminal paradigm shift, and optimize the impact on patient care.
This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...
Confirmatory Factor Analysis of the TerraNova Comprehensive Tests of Basic Skills/5
ERIC Educational Resources Information Center
Stevens, Joseph J.; Zvoch, Keith
2007-01-01
Confirmatory factor analysis was used to explore the internal validity of scores on the TerraNova Comprehensive Tests of Basic Skills/5 using samples from a southwestern school district and standardization samples reported by the publisher. One of the strengths claimed for battery-type achievement tests is provision of reliable and valid samples…
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
Stout, P R; Horn, C K; Klette, K L
2001-10-01
In order to facilitate the confirmation analysis of large numbers of urine samples previously screened positive for delta9-tetrahydrocannabinol (THC), an extraction, derivitization, and GC-MS analysis method was developed. This method utilized a positive pressure manifold anion-exchange polymer-based solid-phase extraction followed by elution directly into the automated liquid sampling (ALS) vials. Rapid derivitization was accomplished using pentafluoropropionic anhydride/pentafluoropropanol (PFPA/PFPOH). Recoveries averaged 95% with a limit of detection of 0.875 ng/mL with a 3-mL sample volume. Performance of 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH)-d3 and THC-COOH-d9 internal standards were evaluated. The method was linear to 900 ng/mL THC-COOH using THC-COOH-d9 with negligible contribution from the internal standard to very weak samples. Excellent agreement was seen with previous quantitations of human urine samples. More than 1000 human urine samples were analyzed using the method with 300 samples analyzed using an alternate qualifier ion (m/z 622) after some interference was observed with a qualifier ion (m/z 489). The 622 ion did not exhibit any interference even in samples with interfering peaks present in the 489 ion. The method resulted in dramatic reductions in processing time, waste production, and exposure hazards to laboratory personnel.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
NASA Astrophysics Data System (ADS)
Aubert, Cédric; Osmond, Mélanie
2008-08-01
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements. The STEME organization, in respect of accreditation references, is presented.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aubert, Cedric; Osmond, Melanie
2008-08-14
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.« less
Development of short and very short forms of the Children's Behavior Questionnaire.
Putnam, Samuel P; Rothbart, Mary K
2006-08-01
Using data from 468 parents and taking into account internal consistency, breadth of item content, within-scale factor analysis, and patterns of missing data, we developed short (94 items, 15 scales) and very short (36 items, 3 broad scales) forms of the Children's Behavior Questionnaire (CBQ; Rothbart, Ahadi, & Hershey, 1994; Rothbart, Ahadi, Hershey, & Fisher, 2001), a well-established parent-report measure of temperament for children aged 3 to 8 years. We subsequently evaluated the forms with data from 1,189 participants. In mid/high-income and White samples, the CBQ short and very short forms demonstrated both satisfactory internal consistency and criterion validity, and exhibited longitudinal stability and cross-informant agreement comparable to that of the standard CBQ. Internal consistency was somewhat lower among African American and low-income samples for some scales. Very short form scales demonstrated acceptable internal consistency for all samples, and confirmatory factor analyses indicated marginal fit of the very short form items to a three-factor model.
Huang, Min; Winters, Doug; Crowley, Richard; Sullivan, Darryl
2009-01-01
A method has been developed for the simultaneous measurement of multiple B vitamins (i.e., B1, B2, B3, B5, and B6) in infant formulas by LC-MSIMS. The vitamins were extracted with acidic solvent, followed by protein precipitation at a pH range of 4.5 to 5.5, and filtered. This simplified procedure eliminates many of the potential sources of laboratory error and facilitates rapid and efficient analysis. As is common in most cases, isotope internal standards were added to account for variations in sample preparation, as well as changes in MS measurement. In this method, isotope-labeled internal standards of B1, B3, B5, and B6 were used. The factors affecting analytical performance were investigated and optimized. In addition, the stability of these vitamins in the extraction solution was investigated. An acidic condition (5 mM HCl) was applied to successfully stabilize B1, which had shown a decrease in signal when other solvents were used. The quantitative extraction and good stability allowed isotope standards to be added to the filtered sample solution, instead of to the extraction solvent. The addition of the isotope to the small portion of the filtered sample solution significantly reduces cost. A comprehensive evaluation of the analysis of the standard reference material and good spike recovery of the vitamins (100 +/- 6%) demonstrates the accuracy of the method. The results for commercially available infant formula samples were also compared with those obtained using the current microbiological method.
Lin, Yi-Reng; Huang, Mei-Fang; Wu, You-Ying; Liu, Meng-Chieh; Huang, Jing-Heng; Chen, Ziyu; Shiue, Yow-Ling; Wu, Chia-En; Liang, Shih-Shin
2017-09-01
In this work, we synthesized internal standards for four garlic organosulfur compounds (OSCs) by reductive amination with 13 C, D 2 -formaldehyde, and developed an isotope dilution analysis method to quantitate these organosulfur components in garlic samples. Internal standards were synthesized for internal absolute quantification of S-allylcysteine (SAC), S-allylcysteine sulfoxide (alliin), S-methylcysteine (SMC), and S-ethylcysteine (SEC). We used a multiple reaction monitoring (MRM) to detect 13 C, D 2 -formaldehyde-modified OSCs by ultrahigh-performance liquid phase chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and obtained MS spectra showing different ratios of 13 C, D 2 -formaldehyde-modified and H 2 -formaldehyde-modified compounds. The resulting labeled and unlabeled OSCs were exhibited correlation coefficient (R 2 ) ranged from 0.9989 to 0.9994, respectively. The average recoveries for four OSCs at three concentration levels ranged from 89% to 105%. By 13 C, D 2 -formaldehyde and sodium cyanoborohydride, the reductive amination-based method can be utilized to generate novel internal standard for isotope dilution and to extend the quantitative application. Copyright © 2017 Elsevier Ltd. All rights reserved.
Liliemark, J; Pettersson, B; Lafolie, P; Zweig, T; Peterson, C
1990-07-01
Two specific high-performance liquid chromatography methods for determining plasma concentrations of azathioprine and 6-mercaptopurine after oral administration of azathioprine are presented. It was shown that azathioprine is unstable in the blood samples unless immediately cooled in ice water. The 2-amino analog, guaneran, was used as internal standard for azathioprine, which was extracted from plasma with ethylacetate. A Nucleosil C18 column was used for the separation. The detection limit was 6 nM. For quantification of 6-mercaptopurine, 6-thioguanine was used as internal standard. Plasma was deproteinized with HClO4 and the sample was purified on mercurial cellulose. A Beckman ODS column was used and the detection limit was 5 nM. Pharmacokinetic data from two patients are presented. Unchanged azathioprine was seen until 6 h after an oral dose of 32 mg/m2.
A workflow to preserve genome-quality tissue samples from plants in botanical gardens and arboreta.
Gostel, Morgan R; Kelloff, Carol; Wallick, Kyle; Funk, Vicki A
2016-09-01
Internationally, gardens hold diverse living collections that can be preserved for genomic research. Workflows have been developed for genomic tissue sampling in other taxa (e.g., vertebrates), but are inadequate for plants. We outline a workflow for tissue sampling intended for two audiences: botanists interested in genomics research and garden staff who plan to voucher living collections. Standard herbarium methods are used to collect vouchers, label information and images are entered into a publicly accessible database, and leaf tissue is preserved in silica and liquid nitrogen. A five-step approach for genomic tissue sampling is presented for sampling from living collections according to current best practices. Collecting genome-quality samples from gardens is an economical and rapid way to make available for scientific research tissue from the diversity of plants on Earth. The Global Genome Initiative will facilitate and lead this endeavor through international partnerships.
Laboratory information management system: an example of international cooperation in Namibia.
Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo
2012-01-01
The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.
Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; González, Héctor; Alvarez, Lydia; Coca-Prados, Miguel; Sanz-Medel, Alfredo
2013-04-01
Laser ablation coupled to inductively coupled plasma mass spectrometry has been developed for the elemental imaging of Mg, Fe and Cu distribution in histological tissue sections of fixed eyes, embedded in paraffin, from human donors (cadavers). This work presents the development of a novel internal standard correction methodology based on the deposition of a homogeneous thin gold film on the tissue surface and the use of the (197)Au(+) signal as internal standard. Sample preparation (tissue section thickness) and laser conditions were carefully optimized, and internal normalisation using (197)Au(+) was compared with (13)C(+) correction for imaging applications. (24)Mg(+), (56)Fe(+) and (63)Cu(+) distributions were investigated in histological sections of the anterior segment of the eye (including the iris, ciliary body, cornea and trabecular meshwork) and were shown to be heterogeneously distributed along those tissue structures. Reproducibility was assessed by imaging different human eye sections from the same donor and from ten different eyes from adult normal donors, which showed that similar spatial maps were obtained and therefore demonstrate the analytical potential of using (197)Au(+) as internal standard. The proposed analytical approach could offer a robust tool with great practical interest for clinical studies, e.g. to investigate trace element distribution of metals and their alterations in ocular diseases.
Ashley, Kevin; Applegate, Gregory T; Marcy, A Dale; Drake, Pamela L; Pierce, Paul A; Carabin, Nathalie; Demange, Martine
2009-02-01
Because toxicities may differ for Cr(VI) compounds of varying solubility, some countries and organizations have promulgated different occupational exposure limits (OELs) for soluble and insoluble hexavalent chromium (Cr(VI)) compounds, and analytical methods are needed to determine these species in workplace air samples. To address this need, international standard methods ASTM D6832 and ISO 16740 have been published that describe sequential extraction techniques for soluble and insoluble Cr(VI) in samples collected from occupational settings. However, no published performance data were previously available for these Cr(VI) sequential extraction procedures. In this work, the sequential extraction methods outlined in the relevant international standards were investigated. The procedures tested involved the use of either deionized water or an ammonium sulfate/ammonium hydroxide buffer solution to target soluble Cr(VI) species. This was followed by extraction in a sodium carbonate/sodium hydroxide buffer solution to dissolve insoluble Cr(VI) compounds. Three-step sequential extraction with (1) water, (2) sulfate buffer and (3) carbonate buffer was also investigated. Sequential extractions were carried out on spiked samples of soluble, sparingly soluble and insoluble Cr(VI) compounds, and analyses were then generally carried out by using the diphenylcarbazide method. Similar experiments were performed on paint pigment samples and on airborne particulate filter samples collected from stainless steel welding. Potential interferences from soluble and insoluble Cr(III) compounds, as well as from Fe(II), were investigated. Interferences from Cr(III) species were generally absent, while the presence of Fe(II) resulted in low Cr(VI) recoveries. Two-step sequential extraction of spiked samples with (first) either water or sulfate buffer, and then carbonate buffer, yielded quantitative recoveries of soluble Cr(VI) and insoluble Cr(VI), respectively. Three-step sequential extraction gave excessively high recoveries of soluble Cr(VI), low recoveries of sparingly soluble Cr(VI), and quantitative recoveries of insoluble Cr(VI). Experiments on paint pigment samples using two-step extraction with water and carbonate buffer yielded varying percentages of relative fractions of soluble and insoluble Cr(VI). Sequential extractions of stainless steel welding fume air filter samples demonstrated the predominance of soluble Cr(VI) compounds in such samples. The performance data obtained in this work support the Cr(VI) sequential extraction procedures described in the international standards.
Vandenabeele-Trambouze, O; Claeys-Bruno, M; Dobrijevic, M; Rodier, C; Borruat, G; Commeyras, A; Garrelly, L
2005-02-01
The need for criteria to compare different analytical methods for measuring extraterrestrial organic matter at ultra-trace levels in relatively small and unique samples (e.g., fragments of meteorites, micrometeorites, planetary samples) is discussed. We emphasize the need to standardize the description of future analyses, and take the first step toward a proposed international laboratory network for performance testing.
Weighing in on international growth standards: testing the case in Australian preschool children.
Pattinson, C L; Staton, S L; Smith, S S; Trost, S G; Sawyer, E F; Thorpe, K J
2017-10-01
Overweight and obesity in preschool-aged children are major health concerns. Accurate and reliable estimates of prevalence are necessary to direct public health and clinical interventions. There are currently three international growth standards used to determine prevalence of overweight and obesity, each using different methodologies: Center for Disease Control (CDC), World Health Organization (WHO) and International Obesity Task Force (IOTF). Adoption and use of each method were examined through a systematic review of Australian population studies (2006-2017). For this period, systematically identified population studies (N = 20) reported prevalence of overweight and obesity ranging between 15 and 38% with most (n = 16) applying the IOTF standards. To demonstrate the differences in prevalence estimates yielded by the IOTF in comparison to the WHO and CDC standards, methods were applied to a sample of N = 1,926 Australian children, aged 3-5 years. As expected, the three standards yielded significantly different estimates when applied to this single population. Prevalence of overweight/obesity was WHO - 9.3%, IOTF - 21.7% and CDC - 33.1%. Judicious selection of growth standards, taking account of their underpinning methodologies and provisions of access to study data sets to allow prevalence comparisons, is recommended. © 2017 World Obesity Federation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carter, Kimberly E; Gerdes, Kirk
2013-07-01
A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GCmore » sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3. This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.« less
[Bacteriological quality of air in a ward for sterile pharmaceutical preparations].
Caorsi P, Beatriz; Sakurada Z, Andrea; Ulloa F, M Teresa; Pezzani V, Marcela; Latorre O, Paz
2011-02-01
An extremely clean area is required for preparation of sterile pharmaceutical compounds, in compliance with international standards, to minimize the probability of microbial contamination. To evaluate the bacteriological quality of the air in the Sterile Pharmaceutical Preparation Unit of the University of Chile's Clinical Hospital and to set up alerts and action levels of bacterial growth. We studied eight representative sites of our Unit on a daily basis from January to February 2005 and twice a week from June 2005 to February 2006. We collected 839 samples of air by impact in the Petri dish. 474 (56.5%) samples were positive; 17 (3.5%) of them had an inappropriate bacterial growth (2% of total samples). The samples from sites 1 and 2 (big and small biosafety cabinets) were negative. The countertop and transfer area occasionally exceeded the bacterial growth limits. The most frequently isolated bacteria were coagulase-negative staphylococci, Micrococcus spp and Corynebacterium spp, from skin microbiota, and Bacillus spp, an environmental bacteria. From a microbiological perspective, the air quality in our sterile preparation unit complied with international standards. Setting institutional alerts and action levels and appropriately identifying bacteria in sensitive areas permits quantification of the microbial load and application of preventive measures.
Toriba, Akira; Kuramae, Yayoi; Chetiyanukornkul, Thaneeya; Kizu, Ryoichi; Makino, Tsunehisa; Nakazawa, Hiroyuki; Hayakawa, Kazuichi
2003-01-01
A high-performance liquid chromatographic (HPLC) method with fluorescence detection was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs) in human hair. Fifteen kinds of PAHs classified as priority pollutants by the US EPA were quantified with four perdeuterated PAHs as internal standards. After 50 mg hair samples were washed with n-hexane to remove external contamination of PAHs, the samples were digested in 2.5 M sodium hydroxide. The digests were extracted with n-hexane and then analyzed by HPLC. Eleven kinds of PAHs were identified in hair samples of 20 subjects, and 10 kinds of PAHs were eventually quantified using the internal standards. For anthracene, chrysene and benzo[k]fluoranthene, significant differences were observed between smokers and non-smokers. Although benzo[b]fluoranthene, dibenz[a,h]anthracene, benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were observed in the particulates of indoor and outdoor air, they were not detected in all hair samples. The analysis of PAHs in human hair should be useful as a new biomarker to evaluate the exposure to PAHs.
Gauw, R D; Stoffolano, P J; Kuhlenbeck, D L; Patel, V S; Garver, S M; Baker, T R; Wehmeyer, K R
2000-07-21
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.
Lapachinske, Silvio Fernandes; Okai, Guilherme Gonçalves; dos Santos, Ariana; de Bairros, André Valle; Yonamine, Mauricio
2015-02-01
Here, gas chromatography with nitrogen phosphorous detector (GC-NPD) method was developed and validated for the quantification of cocaine and adulterants (caffeine, 4-dimethylaminoantipyrine, levamisole, lidocaine and phenacetin) in illicit samples. The method was based on direct dilution of samples in methanol, sonication for 5 min and centrifugation. After appropriate dilution, an aliquot was injected into GC-MS in order to identify the active compounds and into GC-NPD for the analytes quantification. Bupivacaine was used as an internal standard. The method showed to be precise, accurate and linear over a range of 0.5-100% (weight/weight percentages) for all analytes, except phenacetin which showed a linear range between 2% and 100%. The method was successfully applied to 54 samples seized by the Brazilian Federal Police in the International Airport of Sao Paulo and mailing services during the year 2011. All the samples were associated with international trafficking and were apprehended while leaving the country. The purity of cocaine ranged from 16.5% to 91.4%. Cocaine was the only detected active compound in 29.6% of total samples. Among the identified cutting agents, levamisole was the most abundant (55.6% of the total samples) and relative concentrations (weight/weight percentages) ranged from 0.7% to 23%. Lidocaine, caffeine, phenacetin and 4-dimethylaminoantipyrine were also identified in these samples in minor concentrations. In contrast with what we initially hypothesized, drugs intended to international trafficking did not present high cocaine purity and most of the samples were laced with adulterants before leaving Brazil. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Poloskov, Elizabeth; Tracey, Terence J G
2013-09-01
The relationships among acculturation, internalization of U.S. sociocultural standards of female beauty, and body dissatisfaction were examined in a sample of 211 Mexican American college women. Structural equation modeling was used to identify the paths among these three factors. Results demonstrated that there are two distinct types of body dissatisfaction: global evaluations and composite site-specific evaluations. The relationships between acculturation toward dominant U.S. culture and both types of body dissatisfaction were found to be fully mediated by internalization of U.S. standards of female beauty. There were no relationships between Mexican orientation and any of the study variables. The results from this study imply that it is important for therapists working with Mexican American female clients to assess the client's level of acculturation, examine the cultural (U.S. and Mexican) messages the client receives, and explore how these messages impact her body image. Copyright © 2013. Published by Elsevier Ltd.
Ansermot, Nicolas; Rudaz, Serge; Brawand-Amey, Marlyse; Fleury-Souverain, Sandrine; Veuthey, Jean-Luc; Eap, Chin B
2009-08-01
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Mee, Blanaid; Gaffney, Eoin; Glynn, Sharon A; Donatello, Simona; Carroll, Paul; Connolly, Elizabeth; Garrigle, Sarah Mc; Boyle, Terry; Flannery, Delia; Sullivan, Francis J; McCormick, Paul; Griffin, Mairead; Muldoon, Cian; Fay, Joanna; O'Grady, Tony; Kay, Elaine; Eustace, Joe; Burke, Louise; Sheikh, Asim A; Finn, Stephen; Flavin, Richard; Giles, Francis J
2013-02-01
Biobank Ireland Trust (BIT) was established in 2004 to promote and develop an Irish biobank network to benefit patients, researchers, industry, and the economy. The network commenced in 2008 with two hospital biobanks and currently consists of biobanks in the four main cancer hospitals in Ireland. The St. James's Hospital (SJH) Biobank coordinates the network. Procedures, based on ISBER and NCI guidelines, are standardized across the network. Policies and documents-Patient Consent Policy, Patient Information Sheet, Biobank Consent Form, Sample and Data Access Policy (SAP), and Sample Application Form have been agreed upon (after robust discussion) for use in each hospital. An optimum sequence for document preparation and submission for review is outlined. Once consensus is reached among the participating biobanks, the SJH biobank liaises with the Research and Ethics Committees, the Office of the Data Protection Commissioner, The National Cancer Registry (NCR), patient advocate groups, researchers, and other stakeholders. The NCR provides de-identified data from its database for researchers via unique biobank codes. ELSI issues discussed include the introduction of prospective consent across the network and the return of significant research results to patients. Only 4 of 363 patients opted to be re-contacted and re-consented on each occasion that their samples are included in a new project. It was decided, after multidisciplinary discussion, that results will not be returned to patients. The SAP is modeled on those of several international networks. Biobank Ireland is affiliated with international biobanking groups-Marble Arch International Working Group, ISBER, and ESBB. The Irish government continues to deliberate on how to fund and implement biobanking nationally. Meanwhile BIT uses every opportunity to promote awareness of the benefits of biobanking in events and in the media.
Musaiger, Abdulrahman O; Al-Mannai, Mariam; Al-Haifi, Ahmad R; Nabag, Fatima; Elati, Jalila; Abahussain, Nada; Tayyem, Reema; Jalambo, Marwan; Benhamad, Mofida; Al-Mufty, Berivan
2016-09-20
The aim of this study was to highlight the prevalence of overweight and obesity among adolescents in eight Arab countries. A school-based cross-sectional study was conducted in eight Arab countries: Iraq, Jordan, Kuwait, Libya, Palestine, Saudi Arabia, Sudan and Tunisia. The total sample included was 6,447 adolescents aged 15-18 years (3,111 males, 3,336 females). The International Obesity Task Force (IOTF) and World Health Organization (WHO) reference standards were used to determine obesity levels. The WHO standard provided lower prevalence of overweight but higher prevalence of obesity than the IOTF standard. According to the IOTF standard, overweight among males was highest in Kuwaiti adolescents (24.8%), followed by Saudi Arabian (23.2%). Among females, the highest prevalence was reported in Kuwaiti adolescents (22.1%), followed by Jordanian (20.0%). Regarding obesity, Kuwaiti adolescents showed the highest prevalence of obesity for both males (28.6%) and females (21.1%). Findings revealed no progress in reducing prevalence of obesity.
Wadhwa, Meenu; Bird, Chris; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian; Thorpe, Robin
2015-01-01
We assessed the feasibility of developing a suitable international reference standard for determination of in vitro biological activity of human sequence recombinant PEG-G-CSF products with a 20 kD linear PEG linked to the N-terminal methionyl residue of G-CSF (INN Filgrastim), produced using a conjugation process and coupling chemistry similar to that employed for the lead PEGfilgrastim product. Based on initial data which showed that the current WHO 2nd international standard, IS for G-CSF (09/136) or alternatively, a PEG-G-CSF standard with a unitage traceable to the G-CSF IS may potentially serve as the IS for PEG-G-CSF products, two candidate preparations of PEG-G-CSF were formulated and lyophilized at NIBSC. These preparations were tested by 23 laboratories using in vitro bioassays in a multi-centre collaborative study. Results indicated that on the basis of parallelism, the current WHO 2nd IS for G-CSF or any of the PEG-G-CSF samples could be used as the international standard for PEG-G-CSF preparations. However, because of the variability in potency estimates seen when PEG-G-CSF preparations were compared with the current WHO 2nd IS for G-CSF, a candidate PEG-G-CSF was suitable as the WHO IS. The preparation 12/188 was judged suitable to serve as the WHO IS based on in vitro biological activity data. Therefore, the preparation coded 12/188 was established by the WHO Expert Committee on Biological Standardization (ECBS) in 2013 as the WHO 1st IS for human PEGylated G-CSF with an assigned in vitro bioactivity of 10,000 IU per ampoule. PMID:25450254
Determination of tributyltin in whole water matrices under the European Water Framework Directive.
Richter, Janine; Fettig, Ina; Philipp, Rosemarie; Jakubowski, Norbert; Panne, Ulrich; Fisicaro, Paola; Alasonati, Enrica
2016-08-12
Monitoring of water quality is important to control water pollution. Contamination of the aquatic system has a large effect on human health and the environment. Under the European Water Framework Directive (WFD) 2000/60/EC and the related directive on environmental quality standards (EQS) in the field of water policy 2008/105/EC, the need for sensitive reference methods was highlighted. Since tributyltin (TBT) is one of the WFD listed priority substances a method was developed which is capable to qualify and quantify the pollutant at the required low WFD EQS of 0.2ngL(-1) in whole water bodies, i.e. in non-filtered water samples with dissolved organic carbon and suspended particulate matter. Therefore special attention was paid on the interaction of TBT with the suspended particulate matter and humic substances to obtain a complete representation of the pollution in surface waters. Different water samples were investigated varying the content of organic dissolved and suspended matter. Quantification was performed using species-specific isotope dilution (SSID) and gas chromatography with inductively coupled plasma mass spectrometry (GC-ICP-MS). Different sample treatment strategies were evaluated and compared. The process of internal standard addition was investigated and optimized, hence the equilibrium between internal standards and matrix is of primary importance to perform accurate SSID. Samples spiked at EQS level were analyzed with a recovery between 95 and 105 %. Additionally real surface water samples were investigated and the TBT concentration for the whole water body was determined and compared with conventional routine analysis method. Copyright © 2016 Elsevier B.V. All rights reserved.
Quantification of HIV-1 DNA using real-time recombinase polymerase amplification.
Crannell, Zachary Austin; Rohrman, Brittany; Richards-Kortum, Rebecca
2014-06-17
Although recombinase polymerase amplification (RPA) has many advantages for the detection of pathogenic nucleic acids in point-of-care applications, RPA has not yet been implemented to quantify sample concentration using a standard curve. Here, we describe a real-time RPA assay with an internal positive control and an algorithm that analyzes real-time fluorescence data to quantify HIV-1 DNA. We show that DNA concentration and the onset of detectable amplification are correlated by an exponential standard curve. In a set of experiments in which the standard curve and algorithm were used to analyze and quantify additional DNA samples, the algorithm predicted an average concentration within 1 order of magnitude of the correct concentration for all HIV-1 DNA concentrations tested. These results suggest that quantitative RPA (qRPA) may serve as a powerful tool for quantifying nucleic acids and may be adapted for use in single-sample point-of-care diagnostic systems.
Comparison of direct and indirect methods of measuring airborne chrysotile fibre concentration.
Eypert-Blaison, Celine; Veissiere, Sylvie; Rastoix, Olivier; Kauffer, Edmond
2010-01-01
Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission-Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6-14 min does not affect the measured densities, except for fibres <1 microm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.
Giner Martínez-Sierra, J; Santamaria-Fernandez, R; Hearn, R; Marchante Gayón, J M; García Alonso, J I
2010-04-14
In this work, a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) was evaluated for the direct measurement of sulfur stable isotope ratios in beers as a first step toward a general study of the natural isotope variability of sulfur in foods and beverages. Sample preparation consisted of a simple dilution of the beers with 1% (v/v) HNO(3). It was observed that different sulfur isotope ratios were obtained for different dilutions of the same sample indicating that matrix effects affected differently the transmission of the sulfur ions at masses 32, 33, and 34 in the mass spectrometer. Correction for mass bias related matrix effects was evaluated using silicon internal standardization. For that purpose, silicon isotopes at masses 29 and 30 were included in the sulfur cup configuration and the natural silicon content in beers used for internal mass bias correction. It was observed that matrix effects on differential ion transmission could be corrected adequately using silicon internal standardization. The natural isotope variability of sulfur has been evaluated by measuring 26 different beer brands. Measured delta(34)S values ranged from -0.2 to 13.8 per thousand. Typical combined standard uncertainties of the measured delta(34)S values were < or = 2 per thousand. The method has therefore great potential to study sulfur isotope variability in foods and beverages.
Cordeiro, Fernando; Robouch, Piotr; de la Calle, Maria Beatriz; Emteborg, Håkan; Charoud-Got, Jean; Schmitz, Franz
2011-01-01
A collaborative study, International Evaluation Measurement Programme-25a, was conducted in accordance with international protocols to determine the performance characteristics of an analytical method for the determination of dissolved bromate in drinking water. The method should fulfill the analytical requirements of Council Directive 98/83/EC (referred to in this work as the Drinking Water Directive; DWD). The new draft standard method under investigation is based on ion chromatography followed by post-column reaction and UV detection. The collaborating laboratories used the Draft International Organization for Standardization (ISO)/Draft International Standard (DIS) 11206 document. The existing standard method (ISO 15061:2001) is based on ion chromatography using suppressed conductivity detection, in which a preconcentration step may be required for the determination of bromate concentrations as low as 3 to 5 microg/L. The new method includes a dilution step that reduces the matrix effects, thus allowing the determination of bromate concentrations down to 0.5 microg/L. Furthermore, the method aims to minimize any potential interference of chlorite ions. The collaborative study investigated different types of drinking water, such as soft, hard, and mineral water. Other types of water, such as raw water (untreated), swimming pool water, a blank (named river water), and a bromate standard solution, were included as test samples. All test matrixes except the swimming pool water were spiked with high-purity potassium bromate to obtain bromate concentrations ranging from 1.67 to 10.0 microg/L. Swimming pool water was not spiked, as this water was incurred with bromate. Test samples were dispatched to 17 laboratories from nine different countries. Sixteen participants reported results. The repeatability RSD (RSD(r)) ranged from 1.2 to 4.1%, while the reproducibility RSD (RSDR) ranged from 2.3 to 5.9%. These precision characteristics compare favorably with those of ISO 15601. A thorough comparison of the performance characteristics is presented in this report. All method performance characteristics obtained in the frame of this collaborative study indicate that the draft ISO/DIS 11206 standard method meets the requirements set down by the DWD. It can, therefore, be considered to fit its intended analytical purpose.
NASA Astrophysics Data System (ADS)
McFarlane Holman, Karen L.; Latimer, Matthew J.; Yachandra, Vittal K.
2004-06-01
X-ray absorption spectroscopy (XAS) in the intermediate x-ray region (2-6 keV) for dilute biological samples has been limited because of detector/flux limitations and inadequate cryogenic instrumentation. We have designed and constructed a new tailpiece/sample chamber for a commercially available liquid helium cooled cryostat which overcomes difficulties related to low fluorescence signals by using thin window materials and incorporating an internal photodiode detector. With the apparatus, XAS data at the Cl, S, and Ca K edges have been collected on frozen solutions and biological samples at temperatures down to 60 K. A separate chamber has been incorporated for collecting room-temperature spectra of standard compounds (for energy calibration purposes) which prevents contamination of the cryostat chamber and allows the sample to remain undisturbed, both important concerns for studying dilute and radiation-sensitive samples.
The Mars Science Laboratory Organic Check Material
NASA Astrophysics Data System (ADS)
Conrad, Pamela G.; Eigenbrode, Jennifer L.; Von der Heydt, Max O.; Mogensen, Claus T.; Canham, John; Harpold, Dan N.; Johnson, Joel; Errigo, Therese; Glavin, Daniel P.; Mahaffy, Paul R.
2012-09-01
Mars Science Laboratory's Curiosity rover carries a set of five external verification standards in hermetically sealed containers that can be sampled as would be a Martian rock, by drilling and then portioning into the solid sample inlet of the Sample Analysis at Mars (SAM) suite. Each organic check material (OCM) canister contains a porous ceramic solid, which has been doped with a fluorinated hydrocarbon marker that can be detected by SAM. The purpose of the OCM is to serve as a verification tool for the organic cleanliness of those parts of the sample chain that cannot be cleaned other than by dilution, i.e., repeated sampling of Martian rock. SAM possesses internal calibrants for verification of both its performance and its internal cleanliness, and the OCM is not used for that purpose. Each OCM unit is designed for one use only, and the choice to do so will be made by the project science group (PSG).
Roegner, Amber F.; Schirmer, Macarena Pírez; Puschner, Birgit; Brena, Beatriz; Gonzalez-Sapienza, Gualberto
2014-01-01
The freshwater cyanotoxins, microcystins (MCs), pose a global public health threat as potent hepatotoxins in cyanobacterial blooms; their persistence in drinking and recreational water has been associated with potential chronic effects in addition to acute intoxications. Rapid and accurate detection of the over 80 structural congeners is challenged by the rigorous and time consuming clean up required to overcome interference found in raw water samples. MALDI-MS has shown promise for rapid quantification of individual congeners in raw water samples, with very low operative cost, but so far limited sensitivity and lack of available and versatile internal standards (ISs) has limited its use. Two easily synthesized S-hydroxyethyl–Cys(7)-MC-LR and –RR ISs were used to generate linear standard curves in a reflectron MALDI instrument, reproducible across several orders of magnitude for MC –LR, - RR and –YR. Minimum quantification limits in direct water samples with no clean up or concentration step involved were consistently below 7 μg/L, with recoveries from spiked samples between 80 and 119%. This method improves sensitivity by 30 fold over previous reports of quantitative MALDI-TOF applications to MCs and provides a salient option for rapid throughput analysis for multiple MC congeners in untreated raw surface water blooms as a means to identify source public health threats and target intervention strategies within a watershed. As demonstrated by analysis of a set of samples from Uruguay, utilizing the reaction of different MC congeners with alternate sulfhydryl compounds, the m/z of the IS can be customized to avoid overlap with interfering compounds in local surface water samples. PMID:24388801
Influence of furosemide on the detection of flunixin meglumine in horse urine samples.
Araújo, A C; Salvadori, M C; Velletri, M E; Camargo, M M
1990-01-01
The possibility of false negative results from TLC when a diuretic is administered concomitantly with flunixin was studied. Samples were subjected to solvent extraction from acidic aqueous solutions; duplicate samples were also subjected to alkaline hydrolysis at pH 12.5. The internal standard was flufenamic acid. The quantification of flunixin was performed by HPLC and the results confirmed by GC/MS. The data show that furosemide influences the urinary concentration of flunixin.
Moncrieff, J
1994-03-18
A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.
Jiang, Jian; James, Christopher A; Wong, Philip
2016-09-05
A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Lowes, Steve; Jersey, Jim; Shoup, Ronald; Garofolo, Fabio; Savoie, Natasha; Mortz, Ejvind; Needham, Shane; Caturla, Maria Cruz; Steffen, Ray; Sheldon, Curtis; Hayes, Roger; Samuels, Tim; Di Donato, Lorella; Kamerud, John; Michael, Steve; Lin, Zhongping John; Hillier, Jim; Moussallie, Marc; de Souza Teixeira, Leonardo; Rocci, Mario; Buonarati, Mike; Truog, James; Hussain, Saleh; Lundberg, Richard; Breau, Alan; Zhang, Tianyi; Jonker, Jianine; Berger, Neil; Gagnon-Carignan, Sofi; Nehls, Corey; Nicholson, Robert; Hilhorst, Martijn; Karnik, Shane; de Boer, Theo; Houghton, Richard; Smith, Kirk; Cojocaru, Laura; Allen, Mike; Harter, Tammy; Fatmi, Saadya; Sayyarpour, Farhad; Vija, Jenifer; Malone, Michele; Heller, Dennis
2011-06-01
"The Global CRO Council (GCC) for Bioanalysis was formed in an effort to bring together many CRO leaders to openly discuss bioanalysis and the regulatory challenges unique to the outsourcing industry"
Hao, Zhi-hong; Yao, Jian-zhen; Tang, Rui-ling; Zhang, Xue-mei; Li, Wen-ge; Zhang, Qin
2015-02-01
The method for the determmation of trace boron, molybdenum, silver, tin and lead in geochemical samples by direct current are full spectrum direct reading atomic emission spectroscopy (DC-Arc-AES) was established. Direct current are full spectrum direct reading atomic emission spectrometer with a large area of solid-state detectors has functions of full spectrum direct reading and real-time background correction. The new electrodes and new buffer recipe were proposed in this paper, and have applied for national patent. Suitable analytical line pairs, back ground correcting points of elements and the internal standard method were selected, and Ge was used as internal standard. Multistage currents were selected in the research on current program, and each current set different holding time to ensure that each element has a good signal to noise ratio. Continuous rising current mode selected can effectively eliminate the splash of the sample. Argon as shielding gas can eliminate CN band generating and reduce spectral background, also plays a role in stabilizing the are, and argon flow 3.5 L x min(-1) was selected. Evaporation curve of each element was made, and it was concluded that the evaporation behavior of each element is consistent, and combined with the effects of different spectrographic times on the intensity and background, the spectrographic time of 35s was selected. In this paper, national standards substances were selected as a standard series, and the standard series includes different nature and different content of standard substances which meet the determination of trace boron, molybdenum, silver, tin and lead in geochemical samples. In the optimum experimental conditions, the detection limits for B, Mo, Ag, Sn and Pb are 1.1, 0.09, 0.01, 0.41, and 0.56 microg x g(-1) respectively, and the precisions (RSD, n=12) for B, Mo, Ag, Sn and Pb are 4.57%-7.63%, 5.14%-7.75%, 5.48%-12.30%, 3.97%-10.46%, and 4.26%-9.21% respectively. The analytical accuracy was validated by national standards and the results are in agreement with certified values. The method is simple, rapid, is an advanced analytical method for the determination of trace amounts of geochemical samples' boron, molybdenum, silver, tin and lead, and has a certain practicality.
Sun, Y.; Tang, L.; Procop, G. W.; Hillyard, D. R.; Young, S. A.; Caliendo, A. M.
2016-01-01
ABSTRACT It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log10 copies/ml and the overall range for a given sample up to 5.66 log10 copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses. PMID:27852673
Some issues relating to the use of perfluorooctanesulfonate (PFOS) samples as reference standards.
Arsenault, Gilles; Chittim, Brock; McAlees, Alan; McCrindle, Robert; Riddell, Nicole; Yeo, Brian
2008-01-01
Samples of potassium perfluorooctanesulfonate (PFOSK) from three suppliers were analyzed by LC-ESI-MS/MS for purity and by LC-ESI-MS for the percentage of linear isomer present. Our data indicated that the purity ranged from 80% to 98% and the percentages of linear isomer from 67% to 79%. The proportion of branched isomers present in the samples was also estimated using (19)F NMR. These results agreed quite closely with those found by LC-ESI-MS indicating that there is essentially no difference in overall SIM response factor for the branched isomers vs. that of the linear isomer. Several further observations relevant to the use of standards when analyzing for PFOS were encountered during this study. It appears unlikely that matrix effects attributable to the cation (sodium or potassium) present in PFOSNa or PFOSK internal standards is an issue. In seeking potential matrix effects, it was found that the chromatography was improved substantially when the standard was injected as a solution in 80:20 methanol/water rather than 100% methanol. Notably, in concert with the improvement in chromatography, an increase of about 10% in response was observed. In some closely related studies, when (18)O(2) mass-labeled perfluorohexanesulfonate was used as an internal standard, the actual and theoretical concentration ratios matched closely those for related native sulfonates as long as they did not co-elute. However, when they did co-elute, the peak intensities of the native species were enhanced by about 5%, while those of the labeled compound were suppressed by a similar amount. If this effect were not taken into account, the concentration of the native would be inflated by 10%.
Kohlmann, Alexander; Kipps, Thomas J; Rassenti, Laura Z; Downing, James R; Shurtleff, Sheila A; Mills, Ken I; Gilkes, Amanda F; Hofmann, Wolf-Karsten; Basso, Giuseppe; Dell’Orto, Marta Campo; Foà, Robin; Chiaretti, Sabina; De Vos, John; Rauhut, Sonja; Papenhausen, Peter R; Hernández, Jesus M; Lumbreras, Eva; Yeoh, Allen E; Koay, Evelyn S; Li, Rachel; Liu, Wei-min; Williams, Paul M; Wieczorek, Lothar; Haferlach, Torsten
2008-01-01
Gene expression profiling has the potential to enhance current methods for the diagnosis of haematological malignancies. Here, we present data on 204 analyses from an international standardization programme that was conducted in 11 laboratories as a prephase to the Microarray Innovations in LEukemia (MILE) study. Each laboratory prepared two cell line samples, together with three replicate leukaemia patient lysates in two distinct stages: (i) a 5-d course of protocol training, and (ii) independent proficiency testing. Unsupervised, supervised, and r2 correlation analyses demonstrated that microarray analysis can be performed with remarkably high intra-laboratory reproducibility and with comparable quality and reliability. PMID:18573112
Up-regulation of the G3PDH 'housekeeping' gene by estrogen.
Galal, Nadia; El-Beialy, Waleed; Deyama, Yoshiaki; Yoshimura, Yoshitaka; Tei, Kanchu; Suzuki, Kuniaki; Totsuka, Yasunori
2010-01-01
Proteomic and genomic studies commonly involve the assessment of mRNA levels using reverse transcription-polymerase chain reaction (PCR) and real-time quantitative PCR. An internal standard RNA is fundamentally analyzed along with the investigated mRNA to document the specificity of the effect(s) on mRNA and to correct for inter-sample variations. In our studies implementing estrogen treatments on different cell lines, we initially used glyceraldehyde-3-phosphate dehydrogenase (G3PDH) as an internal standard. However, the results of PCR amplification demonstrated that 17β-estradiol enhanced the expression of the G3PDH gene, rendering it impossible to use G3PDH as an unbiased comparative control.
Rodgers, A H; Subramanian, S; Morgan, L R
1995-08-18
An analytical method has been developed for the determination of 4,4'-dihydroxybenzophenone-2,4-dinitrophenylhydrazone (I, trade name A-007) in plasma. Plasma samples are primed with the internal standard, 2,2'-dihydroxybenzophenone-2,4-dinitrophenylhydrazone (II), deproteinized with acetonitrile, centrifuged and filtered prior to assay. The components are then separated on a reversed-phase column with retention times of 4.4 and 6.0 min for I and II, respectively. Ultraviolet detection at 365 nm was employed and little interference with the analyte or the internal standard was noted from other plasma components. This method has been applied to the plasma of rats and monkeys doses for pharmacokinetic and toxicity studies.
NASA Technical Reports Server (NTRS)
Roman, Miguel O.; Nightingale, Joanne; Nickeson, Jaime; Schaepman-Strub, Gabriela
2011-01-01
The goals and objectives of the sub group are: To foster and coordinate quantitative validation of higher level global land products derive d from remotely sensed data, in a traceable way, and to relay results so they are relevant to users. and to increase the quality and effi ciency of global satellite product validation by developing and promo ting international standards and protocols for: (1) Field sampling (2) Scaling techniques (3) Accuracy reporting (4) Data / information exchange also to provide feedback to international structures (GEOSS ) for: (1) Requirements on product accuracy and quality assurance (QA 4EO) (2) Terrestrial ECV measurement standards (3) Definitions for f uture missions
Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.
Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A
2018-02-01
This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.
Standard reference water samples for rare earth element determinations
Verplanck, P.L.; Antweiler, Ronald C.; Nordstrom, D. Kirk; Taylor, Howard E.
2001-01-01
Standard reference water samples (SRWS) were collected from two mine sites, one near Ophir, CO, USA and the other near Redding, CA, USA. The samples were filtered, preserved, and analyzed for rare earth element (REE) concentrations (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) by inductively coupled plasma-mass spectrometry (ICP-MS). These two samples were acid mine waters with elevated concentrations of REEs (0.45-161 ??g/1). Seventeen international laboratories participated in a 'round-robin' chemical analysis program, which made it possible to evaluate the data by robust statistical procedures that are insensitive to outliers. The resulting most probable values are reported. Ten to 15 of the participants also reported values for Ba, Y, and Sc. Field parameters, major ion, and other trace element concentrations, not subject to statistical evaluation, are provided.
Cimino, Matthew T
2010-03-01
Twenty-four herbal dietary supplement powder and extract reference standards provided by the National Institute of Standards and Technology (NIST) were investigated using three different commercially available DNA extraction kits to evaluate DNA availability for downstream nucleotide-based applications. The material included samples of Camellia, Citrus, Ephedra, Ginkgo, Hypericum, Serenoa, And Vaccinium. Protocols from Qiagen, MoBio, and Phytopure were used to isolate and purify DNA from the NIST standards. The resulting DNA concentration was quantified using SYBR Green fluorometry. Each of the 24 samples yielded DNA, though the concentration of DNA from each approach was notably different. The Phytopure method consistently yielded more DNA. The average yield ratio was 22 : 3 : 1 (ng/microL; Phytopure : Qiagen : MoBio). Amplification of the internal transcribed spacer II region using PCR was ultimately successful in 22 of the 24 samples. Direct sequencing chromatograms of the amplified material suggested that most of the samples were comprised of mixtures. However, the sequencing chromatograms of 12 of the 24 samples were sufficient to confirm the identity of the target material. The successful extraction, amplification, and sequencing of DNA from these herbal dietary supplement extracts and powders supports a continued effort to explore nucleotide sequence-based tools for the authentication and identification of plants in dietary supplements. (c) Georg Thieme Verlag KG Stuttgart . New York.
Turak, Fatma; Güzel, Remziye; Dinç, Erdal
2017-04-01
A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA) and caffeine (CAF) in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C 18 column (100 mm × 2.1 mm, 1.7 μm i.d.), using a mobile phase consisting of acetonitrile and 0.2M H 3 PO 4 (11:89, v/v) with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances. Copyright © 2016. Published by Elsevier B.V.
Chiu, Huai-Hsuan; Liao, Hsiao-Wei; Shao, Yu-Yun; Lu, Yen-Shen; Lin, Ching-Hung; Tsai, I-Lin; Kuo, Ching-Hua
2018-08-17
Monoclonal antibody (mAb) drugs have generated much interest in recent years for treating various diseases. Immunoglobulin G (IgG) represents a high percentage of mAb drugs that have been approved by the Food and Drug Administration (FDA). To facilitate therapeutic drug monitoring and pharmacokinetic/pharmacodynamic studies, we developed a general liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify the concentration of IgG-based mAbs in human plasma. Three IgG-based drugs (bevacizumab, nivolumab and pembrolizumab) were selected to demonstrate our method. Protein G beads were used for sample pretreatment due to their universal ability to trap IgG-based drugs. Surrogate peptides that were obtained after trypsin digestion were quantified by using LC-MS/MS. To calibrate sample preparation errors and matrix effects that occur during LC-MS/MS analysis, we used two internal standards (IS) method that include the IgG-based drug-IS tocilizumab and post-column infused IS. Using two internal standards was found to effectively improve quantification accuracy, which was within 15% for all mAb drugs that were tested at three different concentrations. This general method was validated in term of its precision, accuracy, linearity and sensitivity for 3 demonstration mAb drugs. The successful application of the method to clinical samples demonstrated its' applicability in clinical analysis. It is anticipated that this general method could be applied to other mAb-based drugs for use in precision medicine and clinical studies. Copyright © 2018 Elsevier B.V. All rights reserved.
Characterization of Lone Pine, California, tremolite asbestos and preparation of research material
Harper, Martin; Van Gosen, Bradley S.; Crankshaw, Owen S; Doorn, Stacy S; Ennis, J. Todd; Harrison, Sara E
2014-01-01
Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request.
Characterization of Lone Pine, California, Tremolite Asbestos and Preparation of Research Material
Harper, Martin; Van Gosen, Bradley; Crankshaw, Owen S.; Doorn, Stacy S.; Ennis, Todd J.; Harrison, Sara E.
2016-01-01
Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10 g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request. PMID:25268000
Kim, Jong-Seo; Fillmore, Thomas L; Liu, Tao; Robinson, Errol; Hossain, Mahmud; Champion, Boyd L; Moore, Ronald J; Camp, David G; Smith, Richard D; Qian, Wei-Jun
2011-12-01
Selected reaction monitoring (SRM)-MS is an emerging technology for high throughput targeted protein quantification and verification in biomarker discovery studies; however, the cost associated with the application of stable isotope-labeled synthetic peptides as internal standards can be prohibitive for screening a large number of candidate proteins as often required in the preverification phase of discovery studies. Herein we present a proof of concept study using an (18)O-labeled proteome reference as global internal standards (GIS) for SRM-based relative quantification. The (18)O-labeled proteome reference (or GIS) can be readily prepared and contains a heavy isotope ((18)O)-labeled internal standard for every possible tryptic peptide. Our results showed that the percentage of heavy isotope ((18)O) incorporation applying an improved protocol was >99.5% for most peptides investigated. The accuracy, reproducibility, and linear dynamic range of quantification were further assessed based on known ratios of standard proteins spiked into the labeled mouse plasma reference. Reliable quantification was observed with high reproducibility (i.e. coefficient of variance <10%) for analyte concentrations that were set at 100-fold higher or lower than those of the GIS based on the light ((16)O)/heavy ((18)O) peak area ratios. The utility of (18)O-labeled GIS was further illustrated by accurate relative quantification of 45 major human plasma proteins. Moreover, quantification of the concentrations of C-reactive protein and prostate-specific antigen was illustrated by coupling the GIS with standard additions of purified protein standards. Collectively, our results demonstrated that the use of (18)O-labeled proteome reference as GIS provides a convenient, low cost, and effective strategy for relative quantification of a large number of candidate proteins in biological or clinical samples using SRM.
A PEG-Based Hydrogel for Effective Wound Care Management
Chen, Sen-Lu; Fu, Ru-Huei; Liao, Shih-Fei; Liu, Shih-Ping; Lin, Shinn-Zong; Wang, Yu-Chi
2018-01-01
It is extremely challenging to achieve strong adhesion in soft tissues while minimizing toxicity, tissue damage, and other side effects caused by wound sealing materials. In this study, flexible synthetic hydrogel sealants were prepared based on polyethylene glycol (PEG) materials. PEG is a synthetic material that is nontoxic and inert and, thus, suitable for use in medical products. We evaluated the in vitro biocompatibility tests of the dressings to assess cytotoxicity and irritation, sensitization, pyrogen toxicity, and systemic toxicity following the International Organization for Standardization 10993 standards and the in vivo effects of the hydrogel samples using Coloskin liquid bandages as control samples for potential in wound closure. PMID:29637814
Rao, Balaji; Hatzinger, Paul B.; Böhlke, John Karl; Sturchio, Neil C.; Andraski, Brian J.; Eckardt, Frank D.; Jackson, W. Andrew
2010-01-01
A new ion chromatography electrospray tandem mass spectrometry (IC-ESI/MS/MS) method has been developed for quantification and confirmation of chlorate (ClO3−) in environmental samples. The method involves the electro-chemical generation of isotopically labeled chlorate internal standard (Cl18O3−) using 18O water (H218O). The standard was added to all samples prior to analysis thereby minimizing the matrix effects that are associated with common ions without the need for expensive sample pretreatments. The method detection limit (MDL) for ClO3− was 2 ng L−1 for a 1 mL volume sample injection. The proposed method was successfully applied to analyze ClO3− in difficult environmental samples including soil and plant leachates. The IC-ESI/MS/MS method described here was also compared to established EPA method 317.0 for ClO3− analysis. Samples collected from a variety of environments previously shown to contain natural perchlorate (ClO4−) occurrence were analyzed using the proposed method and ClO3− was found to co-occur with ClO4− at concentrations ranging from <2 ng L−1 in precipitation from Texas and Puerto Rico to >500 mg kg−1 in caliche salt deposits from the Atacama Desert in Chile. Relatively low concentrations of ClO3− in some natural groundwater samples (<0.1 μg L−1) analyzed in this work may indicate lower stability when compared to ClO4− in the subsurface. The high concentrations of ClO3− in caliches and soils (3−6 orders of magnitude greater) as compared to precipitation samples indicate that ClO3−, like ClO4−, may be atmospherically produced and deposited, then concentrated in dry soils, and is possibly a minor component in the biogeochemical cycle of chlorine.
Balaji Rao, Balaji Rao; Hatzinger, Paul B; Böhlke, John Karl; Sturchio, Neil C; Andraski, Brian J; Eckardt, Frank D; Jackson, W Andrew
2010-11-15
A new ion chromatography electrospray tandem mass spectrometry (IC-ESI/MS/MS) method has been developed for quantification and confirmation of chlorate (ClO₃⁻) in environmental samples. The method involves the electrochemical generation of isotopically labeled chlorate internal standard (Cl¹⁸O₃⁻) using ¹⁸O water (H₂¹⁸O) he standard was added to all samples prior to analysis thereby minimizing the matrix effects that are associated with common ions without the need for expensive sample pretreatments. The method detection limit (MDL) for ClO₃⁻ was 2 ng L⁻¹ for a 1 mL volume sample injection. The proposed method was successfully applied to analyze ClO₃⁻ in difficult environmental samples including soil and plant leachates. The IC-ESI/MS/MS method described here was also compared to established EPA method 317.0 for ClO₃⁻ analysis. Samples collected from a variety of environments previously shown to contain natural perchlorate (ClO₄⁻) occurrence were analyzed using the proposed method and ClO₃⁻ was found to co-occur with ClO₄⁻ at concentrations ranging from < 2 ng L⁻¹ in precipitation from Texas and Puerto Rico to >500 mg kg⁻¹ in caliche salt deposits from the Atacama Desert in Chile. Relatively low concentrations of ClO₃⁻ in some natural groundwater samples (0.1 µg L⁻¹) analyzed in this work may indicate lower stability when compared to ClO₄⁻ in the subsurface. The high concentrations ClO₃⁻ in caliches and soils (3-6 orders of magnitude greater) as compared to precipitation samples indicate that ClO₃⁻, like ClO₄⁻, may be atmospherically produced and deposited, then concentrated in dry soils, and is possibly a minor component in the biogeochemical cycle of chlorine.
Wang, Xiaoming; Vernikovskaya, Daria I.; Nanovskaya, Tatiana N.; Rytting, Erik; Hankins, Gary D.V.; Ahmed, Mahmoud S.
2013-01-01
A liquid chromatography with single quadrupole mass spectrometry method was developed for the quantitative determination of indomethacin in the maternal plasma and urine of pregnant patients under treatment. A deuterium-labeled isotope of indomethacin (d4-indomethacin) was used as an internal standard. The maternal plasma and urine samples were acidified with 1.0 MHCl then extracted with chloroform to achieve the extraction recovery range of 94% to 104% with variation less than 11%. Chromatographic separation was achieved by a Waters Symmetry C18 column with isocratic elution of 0.05% (v/v) formic acid aqueous solution and acetonitrile (47:53, v/v). An in-source fragmentation was applied on the single quadrupole mass spectrometer equipped with an electrospray ionization source at positive mode. The LC-ESI-MS quantification was performed in the selected ion monitoring mode targeting ions at m/z 139 for indomethacin and m/z 143 for its internal standard. The calibration curves were linear in the concentration ranges between 14.8 and 2.97×103 ng/mL for plasma samples and between 10.5 and 4.21×103 ng/mL for urine samples. The relative standard deviation of this method was less than 8% for intra- and inter-day assays, and the accuracy ranged between 90% and 108%. PMID:23474812
Ye, H P; Shao, J; Tan, S W; Shan, X Y; Shi, Y P
2017-10-20
Objective: To establish a method for determing the trichloroethylene(TCE)and trichloroethanol(TCOH)in blood samples by liquid-liquid extraction-gas chromatography with electron capture detector. Methods: With this method,ether was used as extraction solvent and trichloromethane was used as an internal standard. The whole blood sample was extracted with ether, and dehydrated by anhydrous sodium sulfate. Then the analytes were separated on HP-5 capillary column(30m×0.32mm×0.15μm)and detected byECD.The retention time was for qualitative analysis and the internal standard was for quantitation. Results: The standard curves of TCE and TCOH showed significant linearity between 95.5μg/L-7640.0μg/L( r =0.9997)and 19.0μg/L-1520.0μg/L( r =0.9992). The average recovery was 95.5%-103.6%.The intra-day and inter-day precisions( RSD )were 2.5%-6.8%( n =6)and 1.6%-4.3%( n =6) respectively. The detect limit of TCE and TCOH were 2.10 μg/L and 0.56μg/L(S/N=3)respectively.The blood can be kept 7 days at-20℃ refrigerator without significantly loss. Conclusion: This method is proved to be simple,practical and highly sensitive. It can satisfy the request for the determination of blood samples of humans exposed to TCE.
Lien, Stina K; Kvitvang, Hans Fredrik Nyvold; Bruheim, Per
2012-07-20
GC-MS analysis of silylated metabolites is a sensitive method that covers important metabolite groups such as sugars, amino acids and non-amino organic acids, and it has become one of the most important analytical methods for exploring the metabolome. Absolute quantitative GC-MS analysis of silylated metabolites poses a challenge as different metabolites have different derivatization kinetics and as their silyl-derivates have varying stability. This report describes the development of a targeted GC-MS/MS method for quantification of metabolites. Internal standards for each individual metabolite were obtained by derivatization of a mixture of standards with deuterated N-methyl-N-trimethylsilyltrifluoroacetamide (d9-MSTFA), and spiking this solution into MSTFA derivatized samples prior to GC-MS/MS analysis. The derivatization and spiking protocol needed optimization to ensure that the behaviour of labelled compound responses in the spiked sample correctly reflected the behaviour of unlabelled compound responses. Using labelled and unlabelled MSTFA in this way enabled normalization of metabolite responses by the response of their deuterated counterpart (i.e. individual correction). Such individual correction of metabolite responses reproducibly resulted in significantly higher precision than traditional data correction strategies when tested on samples both with and without serum and urine matrices. The developed method is thus a valuable contribution to the field of absolute quantitative metabolomics. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makoto Kashiwagi; Garamszeghy, Mike; Lantes, Bertrand
Disposal of low-and intermediate-level activated waste generated at nuclear power plants is being planned or carried out in many countries. The radioactivity concentrations and/or total quantities of long-lived, difficult-to-measure nuclides (DTM nuclides), such as C-14, Ni-63, Nb-94, α emitting nuclides etc., are often restricted by the safety case for a final repository as determined by each country's safety regulations, and these concentrations or amounts are required to be known and declared. With respect to waste contaminated by contact with process water, the Scaling Factor method (SF method), which is empirically based on sampling and analysis data, has been applied asmore » an important method for determining concentrations of DTM nuclides. This method was standardized by the International Organization for Standardization (ISO) and published in 2007 as ISO21238 'Scaling factor method to determine the radioactivity of low and intermediate-level radioactive waste packages generated at nuclear power plants' [1]. However, for activated metal waste with comparatively high concentrations of radioactivity, such as may be found in reactor control rods and internal structures, direct sampling and radiochemical analysis methods to evaluate the DTM nuclides are limited by access to the material and potentially high personnel radiation exposure. In this case, theoretical calculation methods in combination with empirical methods based on remote radiation surveys need to be used to best advantage for determining the disposal inventory of DTM nuclides while minimizing exposure to radiation workers. Pursuant to this objective a standard for the theoretical evaluation of the radioactivity concentration of DTM nuclides in activated waste, is in process through ISO TC85/SC5 (ISO Technical Committee 85: Nuclear energy, nuclear technologies, and radiological protection; Subcommittee 5: Nuclear fuel cycle). The project team for this ISO standard was formed in 2011 and is composed of experts from 11 countries. The project team has been conducting technical discussions on theoretical methods for determining concentrations of radioactivity, and has developed the draft International Standard of ISO16966 'Theoretical activation calculation method to evaluate the radioactivity of activated waste generated at nuclear reactors' [2]. This paper describes the international standardization process developed by the ISO project team, and outlines the following two theoretical activity evaluation methods:? Point method? Range method. (authors)« less
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-105 (7 A.1) flight to the ISS is reported. ISS air samples were taken in August 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and surrogate standard recoveries were 64-115%. Pressure tracking indicated no leaks in the canisters.
Fortini, Martina; Migliorini, Marzia; Cherubini, Chiara; Cecchi, Lorenzo; Calamai, Luca
2017-04-01
The commercial value of virgin olive oils (VOOs) strongly depends on their classification, also based on the aroma of the oils, usually evaluated by a panel test. Nowadays, a reliable analytical method is still needed to evaluate the volatile organic compounds (VOCs) and support the standard panel test method. To date, the use of HS-SPME sampling coupled to GC-MS is generally accepted for the analysis of VOCs in VOOs. However, VOO is a challenging matrix due to the simultaneous presence of: i) compounds at ppm and ppb concentrations; ii) molecules belonging to different chemical classes and iii) analytes with a wide range of molecular mass. Therefore, HS-SPME-GC-MS quantitation based upon the use of external standard method or of only a single internal standard (ISTD) for data normalization in an internal standard method, may be troublesome. In this work a multiple internal standard normalization is proposed to overcome these problems and improving quantitation of VOO-VOCs. As many as 11 ISTDs were used for quantitation of 71 VOCs. For each of them the most suitable ISTD was selected and a good linearity in a wide range of calibration was obtained. Except for E-2-hexenal, without ISTD or with an unsuitable ISTD, the linear range of calibration was narrower with respect to that obtained by a suitable ISTD, confirming the usefulness of multiple internal standard normalization for the correct quantitation of VOCs profile in VOOs. The method was validated for 71 VOCs, and then applied to a series of lampante virgin olive oils and extra virgin olive oils. In light of our results, we propose the application of this analytical approach for routine quantitative analyses and to support sensorial analysis for the evaluation of positive and negative VOOs attributes. Copyright © 2017 Elsevier B.V. All rights reserved.
The role of self-interest in elite bargaining.
LeVeck, Brad L; Hughes, D Alex; Fowler, James H; Hafner-Burton, Emilie; Victor, David G
2014-12-30
One of the best-known and most replicated laboratory results in behavioral economics is that bargainers frequently reject low offers, even when it harms their material self-interest. This finding could have important implications for international negotiations on many problems facing humanity today, because models of international bargaining assume exactly the opposite: that policy makers are rational and self-interested. However, it is unknown whether elites who engage in diplomatic bargaining will similarly reject low offers because past research has been based almost exclusively on convenience samples of undergraduates, members of the general public, or small-scale societies rather than highly experienced elites who design and bargain over policy. Using a unique sample of 102 policy and business elites who have an average of 21 y of practical experience conducting international diplomacy or policy strategy, we show that, compared with undergraduates and the general public, elites are actually more likely to reject low offers when playing a standard "ultimatum game" that assesses how players bargain over a fixed resource. Elites with more experience tend to make even higher demands, suggesting that this tendency only increases as policy makers advance to leadership positions. This result contradicts assumptions of rational self-interested behavior that are standard in models of international bargaining, and it suggests that the adoption of global agreements on international trade, climate change, and other important problems will not depend solely on the interests of individual countries, but also on whether these accords are seen as equitable to all member states.
The role of self-interest in elite bargaining
LeVeck, Brad L.; Hughes, D. Alex; Fowler, James H.; Hafner-Burton, Emilie; Victor, David G.
2014-01-01
One of the best-known and most replicated laboratory results in behavioral economics is that bargainers frequently reject low offers, even when it harms their material self-interest. This finding could have important implications for international negotiations on many problems facing humanity today, because models of international bargaining assume exactly the opposite: that policy makers are rational and self-interested. However, it is unknown whether elites who engage in diplomatic bargaining will similarly reject low offers because past research has been based almost exclusively on convenience samples of undergraduates, members of the general public, or small-scale societies rather than highly experienced elites who design and bargain over policy. Using a unique sample of 102 policy and business elites who have an average of 21 y of practical experience conducting international diplomacy or policy strategy, we show that, compared with undergraduates and the general public, elites are actually more likely to reject low offers when playing a standard “ultimatum game” that assesses how players bargain over a fixed resource. Elites with more experience tend to make even higher demands, suggesting that this tendency only increases as policy makers advance to leadership positions. This result contradicts assumptions of rational self-interested behavior that are standard in models of international bargaining, and it suggests that the adoption of global agreements on international trade, climate change, and other important problems will not depend solely on the interests of individual countries, but also on whether these accords are seen as equitable to all member states. PMID:25512497
ERIC Educational Resources Information Center
Fofonoff, N. P.; Millard, R. C., Jr.
Algorithms for computation of fundamental properties of seawater, based on the practicality salinity scale (PSS-78) and the international equation of state for seawater (EOS-80), are compiled in the present report for implementing and standardizing computer programs for oceanographic data processing. Sample FORTRAN subprograms and tables are given…
Biomedical graphite and CaF2 preparation and measurement at PRIME Lab
NASA Astrophysics Data System (ADS)
Jackson, George S.; Einstein, Jane A.; Kubley, Tom; Martin, Berdine; Weaver, Connie M.; Caffee, Marc
2015-10-01
The biomedical program at PRIME Lab has prepared radiocarbon and 41Ca as tracers for a variety of applications. Over the last decade several hundred 14C samples and several thousand 41Ca samples have been measured per year. Biomedical samples pose challenges that are relatively rare in the AMS community. We will discuss how to prepare and compensate for samples that have isotope ratios above the dynamic range of AMS, high interference rates, and small samples sizes. In the case of 41Ca, the trade off in the chromatography between yield and sample cleanliness will be analyzed. Secondary standards that have isotope ratios commonly encountered in our applications are routinely prepared. We use material from the Joint Research Centre's Institute for Reference Materials and Measurement: IRMM-3701/4, 3701/5, and 3701/6 and a standard produced by PRIME Lab for 41Ca. We use International Atomic Energy Agency's IAEA C-3, IAEA C-7, IAEA C-8, and a ∼12.5× modern oxalic acid secondary standard supplied by Lawrence Livermore National Laboratory for 14C. We will discuss our precision, reproducibility, and the relative agreement between our measured and the reported values for these materials.
A workflow to preserve genome-quality tissue samples from plants in botanical gardens and arboreta1
Gostel, Morgan R.; Kelloff, Carol; Wallick, Kyle; Funk, Vicki A.
2016-01-01
Premise of the study: Internationally, gardens hold diverse living collections that can be preserved for genomic research. Workflows have been developed for genomic tissue sampling in other taxa (e.g., vertebrates), but are inadequate for plants. We outline a workflow for tissue sampling intended for two audiences: botanists interested in genomics research and garden staff who plan to voucher living collections. Methods and Results: Standard herbarium methods are used to collect vouchers, label information and images are entered into a publicly accessible database, and leaf tissue is preserved in silica and liquid nitrogen. A five-step approach for genomic tissue sampling is presented for sampling from living collections according to current best practices. Conclusions: Collecting genome-quality samples from gardens is an economical and rapid way to make available for scientific research tissue from the diversity of plants on Earth. The Global Genome Initiative will facilitate and lead this endeavor through international partnerships. PMID:27672517
NASA Astrophysics Data System (ADS)
Wang, Chia-Wei; Chen, Wen-Tsen; Chang, Huan-Tsung
2014-07-01
Quantification of monosaccharides and disaccharides in five honey samples through surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using HgTe nanostructures as the matrix and sucralose as an internal standard has been demonstrated. Under optimal conditions (1× HgTe nanostructure, 0.2 mM ammonium citrate at pH 9.0), the SALDI-MS approach allows detection of fructose and maltose at the concentrations down to 15 and 10 μM, respectively. Without conducting tedious sample pretreatment and separation, the SALDI-MS approach allows determination of the contents of monosaccharides and disaccharides in honey samples within 30 min, with reproducibility (relative standard deviation <15%). Unlike only sodium adducts of standard saccharides detected, sodium adducts and potassium adducts with differential amounts have been found among various samples, showing different amounts of sodium and potassium ions in the honey samples. The SALDI-MS data reveal that the contents of monosaccharides and disaccharides in various honey samples are dependent on their nectar sources. In addition to the abundant amounts of monosaccharides and disaccharides, oligosaccharides in m/z range of 650 - 2700 are only detected in pomelo honey. Having advantages of simplicity, rapidity, and reproducibility, this SALDI-MS holds great potential for the analysis of honey samples.
Wang, Chia-Wei; Chen, Wen-Tsen; Chang, Huan-Tsung
2014-07-01
Quantification of monosaccharides and disaccharides in five honey samples through surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using HgTe nanostructures as the matrix and sucralose as an internal standard has been demonstrated. Under optimal conditions (1× HgTe nanostructure, 0.2 mM ammonium citrate at pH 9.0), the SALDI-MS approach allows detection of fructose and maltose at the concentrations down to 15 and 10 μM, respectively. Without conducting tedious sample pretreatment and separation, the SALDI-MS approach allows determination of the contents of monosaccharides and disaccharides in honey samples within 30 min, with reproducibility (relative standard deviation <15%). Unlike only sodium adducts of standard saccharides detected, sodium adducts and potassium adducts with differential amounts have been found among various samples, showing different amounts of sodium and potassium ions in the honey samples. The SALDI-MS data reveal that the contents of monosaccharides and disaccharides in various honey samples are dependent on their nectar sources. In addition to the abundant amounts of monosaccharides and disaccharides, oligosaccharides in m/z range of 650 - 2700 are only detected in pomelo honey. Having advantages of simplicity, rapidity, and reproducibility, this SALDI-MS holds great potential for the analysis of honey samples.
Nasirian, Hassan; Vazirianzadeh, Babak; Taghi Sadeghi, Sayyed Mohammad; Nazmara, Shahrokh
2014-01-01
Abstract The quantity of some trace metals of mosquito larvae in Shadegan International Wetland from Iran was evaluated. Water, waterbed sediment, and mosquito larvae samplings were carried out from an urban site in the east of the wetland, using standard methods in December 2011. The identified Culiseta subochrea (Edwards) and Aedes caspius s.l. (Pallas) larvae, water, and waterbed sediment samples were analyzed for As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Pb, and Zn trace metals using standard preparation and isolation procedure. Result showed that the waterbed sediment and Cu. subochrea larvae are polluted with all trace metals investigated except As and Hg. The trace metals bioaccumulated in the Cu. subochrea larvae range from 31.78 at the lowest level for Cr to 3822.7 at the highest level for Cd. In a conclusion, this is the first report confirmed that Cu. subochrea likely used as a bioindicator to trace metal pollution in marine ecosystems in the world, especially wetlands. PMID:25550357
Bashir, Fathi Alhashmi; Shuhaimi-Othman, Mohammad; Mazlan, A. G.
2012-01-01
This study is focused on evaluating the trace metal levels in water and tissues of two commercial fish species Arius thalassinus and Pennahia anea that were collected from Kapar and Mersing coastal waters. The concentrations of Fe, Zn, Al, As, Cd and Pb in these coastal waters and muscle, liver and gills tissues of the fishes were quantified. The relationship among the metal concentrations and the height and weight of the two species were also examined. Generally, the iron has the highest concentrations in both water and the fish species. However, Cd in both coastal waters showed high levels exceeding the international standards. The metal level concentration in the sample fishes are in the descending order livers > gills > muscles. A positive association between the trace metal concentrations and weight and length of the sample fishes was investigated. Fortunately the level of these metal concentrations in fish has not exceeded the permitted level of Malaysian and international standards. PMID:22046193
Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.
Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan
2012-10-01
To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas
2014-01-01
Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.
Commutability of Cytomegalovirus WHO International Standard in Different Matrices
Jones, Sara; Webb, Erika M.; Barry, Catherine P.; Choi, Won S.; Abravaya, Klara B.; Schneider, George J.
2016-01-01
Commutability of quantitative standards allows patient results to be compared across molecular diagnostic methods and laboratories. This is critical to establishing quantitative thresholds for use in clinical decision-making. A matrix effect associated with the 1st cytomegalovirus (CMV) WHO international standard (IS) was identified using the Abbott RealTime CMV assay. A commutability study was performed to compare the CMV WHO IS and patient specimens diluted in plasma and whole blood. Patient specimens showed similar CMV DNA quantitation values regardless of the diluent or extraction procedure used. The CMV WHO IS, on the other hand, exhibited a matrix effect. The CMV concentration reported for the WHO IS diluted in plasma was within the 95% prediction interval established with patient samples. In contrast, the reported DNA concentration of the CMV WHO IS diluted in whole blood was reduced approximately 0.4 log copies/ml, and values fell outside the 95% prediction interval. Calibrating the assay by using the CMV WHO IS diluted in whole blood would introduce a bias for CMV whole-blood quantitation; samples would be reported as having higher measured concentrations, by approximately 0.4 log IU/ml. Based on the commutability study with patient samples, the RealTime CMV assay was standardized based on the CMV WHO IS diluted in plasma. A revision of the instructions for use of the CMV WHO IS should be considered to alert users of the potential impact from the diluent matrix. The identification of a matrix effect with the CMV WHO IS underscores the importance of assessing commutability of the IS in order to achieve consistent results across methods. PMID:27030491
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoogheem, T.J.; Woods, L.A.
The Monsanto Analytical Testing (MAT) program was devised and implemented in order to provide analytical standards to Monsanto manufacturing plants involved in the self-monitoring of plant discharges as required by National Pollutant Discharge Elimination System (NPDES) permit conditions. Standards are prepared and supplied at concentration levels normally observed at each individual plant. These levels were established by canvassing all Monsanto plants having NPDES permits and by determining which analyses and concentrations were most appropriate. Standards are prepared by Monsanto's analyses and concentrations were most appropriate. Standards are prepared by Monsanto's Environmental Sciences Center (ESC) using Environmental Protection Agency (EPA) methods.more » Eleven standards are currently available, each in three concentrations. Standards are issued quarterly in a company internal round-robin program or on a per request basis or both. Since initiation of the MAT program in 1981, the internal round-robin program has become an integral part of Monsanto's overall Good Laboratory Practices (GLP) program. Overall, results have shown that the company's plant analytical personnel can accurately analyze and report standard test samples. More importantly, such personnel have gained increased confidence in their ability to report accurate values for compounds regulated in their respective plant NPDES permits. 3 references, 3 tables.« less
Mirzaei, Hamid; Brusniak, Mi-Youn; Mueller, Lukas N; Letarte, Simon; Watts, Julian D; Aebersold, Ruedi
2009-08-01
As the application for quantitative proteomics in the life sciences has grown in recent years, so has the need for more robust and generally applicable methods for quality control and calibration. The reliability of quantitative proteomics is tightly linked to the reproducibility and stability of the analytical platforms, which are typically multicomponent (e.g. sample preparation, multistep separations, and mass spectrometry) with individual components contributing unequally to the overall system reproducibility. Variations in quantitative accuracy are thus inevitable, and quality control and calibration become essential for the assessment of the quality of the analyses themselves. Toward this end, the use of internal standards cannot only assist in the detection and removal of outlier data acquired by an irreproducible system (quality control) but can also be used for detection of changes in instruments for their subsequent performance and calibration. Here we introduce a set of halogenated peptides as internal standards. The peptides are custom designed to have properties suitable for various quality control assessments, data calibration, and normalization processes. The unique isotope distribution of halogenated peptides makes their mass spectral detection easy and unambiguous when spiked into complex peptide mixtures. In addition, they were designed to elute sequentially over an entire aqueous to organic LC gradient and to have m/z values within the commonly scanned mass range (300-1800 Da). In a series of experiments in which these peptides were spiked into an enriched N-glycosite peptide fraction (i.e. from formerly N-glycosylated intact proteins in their deglycosylated form) isolated from human plasma, we show the utility and performance of these halogenated peptides for sample preparation and LC injection quality control as well as for retention time and mass calibration. Further use of the peptides for signal intensity normalization and retention time synchronization for selected reaction monitoring experiments is also demonstrated.
Nilsson, Lars B; Skansen, Patrik
2012-06-30
The investigations in this article were triggered by two observations in the laboratory; for some liquid chromatography/tandem mass spectrometry (LC/MS/MS) systems it was possible to obtain linear calibration curves for extreme concentration ranges and for some systems seemingly linear calibration curves gave good accuracy at low concentrations only when using a quadratic regression function. The absolute and relative responses were tested for three different LC/MS/MS systems by injecting solutions of a model compound and a stable isotope labeled internal standard. The analyte concentration range for the solutions was 0.00391 to 500 μM (128,000×), giving overload of the chromatographic column at the highest concentrations. The stable isotope labeled internal standard concentration was 0.667 μM in all samples. The absolute response per concentration unit decreased rapidly as higher concentrations were injected. The relative response, the ratio for the analyte peak area to the internal standard peak area, per concentration unit was calculated. For system 1, the ionization process was found to limit the response and the relative response per concentration unit was constant. For systems 2 and 3, the ion detection process was the limiting factor resulting in decreasing relative response at increasing concentrations. For systems behaving like system 1, simple linear regression can be used for any concentration range while, for systems behaving like systems 2 and 3, non-linear regression is recommended for all concentration ranges. Another consequence is that the ionization capacity limited systems will be insensitive to matrix ion suppression when an ideal internal standard is used while the detection capacity limited systems are at risk of giving erroneous results at high concentrations if the matrix ion suppression varies for different samples in a run. Copyright © 2012 John Wiley & Sons, Ltd.
Sapsirisavat, Vorapot; Vongsutilers, Vorasit; Thammajaruk, Narukjaporn; Pussadee, Kanitta; Riyaten, Prakit; Kerr, Stephen; Avihingsanon, Anchalee; Phanuphak, Praphan; Ruxrungtham, Kiat
2016-01-01
Ensuring that medicines meet quality standards is mandatory for ensuring safety and efficacy. There have been occasional reports of substandard generic medicines, especially in resource-limiting settings where policies to control quality may be less rigorous. As HIV treatment in Thailand depends mostly on affordable generic antiretrovirals (ARV), we performed quality assurance testing of several generic ARV available from different sources in Thailand and a source from Vietnam. We sampled Tenofovir 300mg, Efavirenz 600mg and Lopinavir/ritonavir 200/50mg from 10 primary hospitals randomly selected from those participating in the National AIDS Program, 2 non-government organization ARV clinics, and 3 private drug stores. Quality of ARV was analyzed by blinded investigators at the Faculty of Pharmaceutical Science, Chulalongkorn University. The analysis included an identification test for drug molecules, a chemical composition assay to quantitate the active ingredients, a uniformity of mass test and a dissolution test to assess in-vitro drug release. Comparisons were made against the standards described in the WHO international pharmacopeia. A total of 42 batches of ARV from 15 sources were sampled from January-March 2015. Among those generics, 23, 17, 1, and 1 were Thai-made, Indian-made, Vietnamese-made and Chinese-made, respectively. All sampled products, regardless of manufacturers or sources, met the International Pharmacopeia standards for composition assay, mass uniformity and dissolution. Although local regulations restrict ARV supply to hospitals and clinics, samples of ARV could be bought from private drug stores even without formal prescription. Sampled generic ARVs distributed within Thailand and 1 Vietnamese pharmacy showed consistent quality. However some products were illegally supplied without prescription, highlighting the importance of dispensing ARV for treatment or prevention in facilities where continuity along the HIV treatment and care cascade is available.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2007-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
González Jiménez, E; Aguilar Cordero, M J; Álvarez Ferre, J; Padilla López, C; Valenza, M C
2012-01-01
Recent studies show an alarming increase in levels of overweight and obesity among children and adolescents. The main objectives of this research were the following: (i) to carry out an anthropometric evaluation of the nutritional status and body composition of school children in the city and province of Granada; (ii) to compare the nutritional status of this population sample with national and international reference standards. The results obtained in this study showed that the general prevalence of overweight in both sexes was 22.03% and that 9.12% of the children were obese. Statistically significant differences were found between the variable, weight for age and sex (p < 0.05) and the variable, height for age and sex (p < 0.05). Regarding the body mass index, no statistically significant differences were found for the variable, sex (p = 0.182). This contrasted with the variable, age, which did show statistically significant differences (p < 0.05). As a conclusion, the results of our study highlighted the fact that these anthropometric values were much higher than national and international reference standards.
Poirier, Jean-Marie; Robidou, Pascal; Jaillon, Patrice
2008-05-15
A simple and sensitive HLPC method with fluorescence detection was developed for the accurate determination of the first licensed HIV integrase inhibitor raltegravir in human plasma. A 500-microL plasma sample was spiked with delavirdine as internal standard and subjected to liquid-liquid extraction based on a previously described assay i.e. using hexane/methylene chloride (1:1, v/v%) at pH 4.0. HPLC was performed using a Symmetry Shield RP18 column (150 mm x 4.6 mm), a gradient elution of acetonitrile -0.01% (v/v) triethylamine in water adjusted to pH 3.0 at a flow rate of 1 mL/min and a fluorimetric detector set at 299 and 396 nm as excitation and emission wavelengths, respectively. The retention time was 5.0 min for internal standard and 6.4 min for raltegravir. Calibration curves were linear in the range 5-1000 ng/mL and the accuracy of quality control samples in the range 10-750 ng/mL varied from 98.3 to 99.1% and 98.3 to 101.0% of the nominal concentrations for intra-day and day-to-day analysis, respectively with a precision of 6.3% or less. Among the other antiretroviral drugs which can be given in association to HIV-infected patients, none was found to interfere with internal standard or raltegravir. The described assay was developed for the purpose of therapeutic drug of this HIV integrase inhibitor.
Chang, Kai-Chun; Chang, Yu-Ting; Tsai, Chin-En
2018-04-01
A liquid chromatography tandem mass spectrometric method was developed for the determination of two β-agonists (ractopamine and salbutamol) in pig hair samples. An isotope of ractopamine-d5 or salbutamol-d6 as an internal standard was used to carry out quantitative analysis. Concentrated sodium hydroxide was used to pretreat hair samples and then purified by the solid phase extraction (SPE) procedure. The extracted solution was evaporated and reconstituted for injection in the instrument with electrospray ionization (ESI) operating in a positive multiple-reaction-monitoring (MRM) mode. Ractopamine and salbutamol separation were performed on C18 analytical column under gradient condition. The internal standard calibration curve was linear in the range of concentration from 0.5 to 100 ng mL -1 (R 2 > 0.995). Recoveries of this method estimated at three spiked concentrations of 100, 250 and 500 ng mL -1 in pig hair samples, were 79-82% for ractopamine and 77-96% for salbutamol. The corresponding inter-day and intra-day precisions expressed as relative standard deviation (RSD %) were 3.8-6.4% and 3.8-8.6%, respectively. The analytical time for one sample was 8 min. The detection limit of this method was 0.6 and 8.3 ng mL -1 for ractopamine and salbutamol, respectively. This developed method can be applied for monitoring the use of the β-agonists salbutamol and ractopamine in swine feed incurred pig hair. Copyright © 2017. Published by Elsevier B.V.
Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry
NASA Astrophysics Data System (ADS)
Kolářová, Lenka; Prokeš, Lubomír; Kučera, Lukáš; Hampl, Aleš; Peňa-Méndez, Eladia; Vaňhara, Petr; Havel, Josef
2017-03-01
Precise calibration in TOF MS requires suitable and reliable standards, which are not always available for high masses. We evaluated inorganic clusters of the monoisotopic elements gold and phosphorus (Au n +/Au n - and P n +/P n -) as an alternative to peptides or proteins for the external and internal calibration of mass spectra in various experimental and instrumental scenarios. Monoisotopic gold or phosphorus clusters can be easily generated in situ from suitable precursors by laser desorption/ionization (LDI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Their use offers numerous advantages, including simplicity of preparation, biological inertness, and exact mass determination even at lower mass resolution. We used citrate-stabilized gold nanoparticles to generate gold calibration clusters, and red phosphorus powder to generate phosphorus clusters. Both elements can be added to samples to perform internal calibration up to mass-to-charge ( m/z) 10-15,000 without significantly interfering with the analyte. We demonstrated the use of the gold and phosphorous clusters in the MS analysis of complex biological samples, including microbial standards and total extracts of mouse embryonic fibroblasts. We believe that clusters of monoisotopic elements could be used as generally applicable calibrants for complex biological samples.
Larivière, Dominic; Tremblay, Mélodie; Durand-Jézéquel, Myriam; Tolmachev, Sergei
2012-04-01
This article describes a robust methodology using the combination of instrumental design (high matrix interface-HMI), sample dilution and internal standardization for the quantification of beryllium (Be) in various digested autopsy tissues using inductively coupled plasma mass spectrometry. The applicability of rhodium as a proper internal standard for Be was demonstrated in three types of biological matrices (i.e., femur, hair, lung tissues). Using HMI, it was possible to achieve instrumental detection limits and sensitivity of 0.6 ng L(-1) and 157 cps L ng(-1), respectively. Resilience to high salt matrices of the HMI setup was also highlighted using bone mimicking solution ([Ca(2+)] = 26 to 1,400 mg L(-1)), providing a 14-fold increase in tolerance and a 2.7-fold decrease in method detection limit compared to optimized experimental conditions obtained without the HMI configuration. Precision of the methodology to detect low levels of Be in autopsy samples was demonstrated using hair and blood certified reference materials. Be concentration ranging from 0.015 to 255 μg kg(-1) in autopsy samples obtained from the U.S. Transuranium and Uranium Registries were measured using the methodology presented.
Damond, F; Benard, A; Balotta, Claudia; Böni, Jürg; Cotten, Matthew; Duque, Vitor; Ferns, Bridget; Garson, Jeremy; Gomes, Perpetua; Gonçalves, Fátima; Gottlieb, Geoffrey; Kupfer, Bernd; Ruelle, Jean; Rodes, Berta; Soriano, Vicente; Wainberg, Mark; Taieb, Audrey; Matheron, Sophie; Chene, Genevieve; Brun-Vezinet, Francoise
2011-10-01
Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHI(E)V(2E) study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log(10) copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log(10) copies/ml and 3.7 log(10) copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed.
Damond, F.; Benard, A.; Balotta, Claudia; Böni, Jürg; Cotten, Matthew; Duque, Vitor; Ferns, Bridget; Garson, Jeremy; Gomes, Perpetua; Gonçalves, Fátima; Gottlieb, Geoffrey; Kupfer, Bernd; Ruelle, Jean; Rodes, Berta; Soriano, Vicente; Wainberg, Mark; Taieb, Audrey; Matheron, Sophie; Chene, Genevieve; Brun-Vezinet, Francoise
2011-01-01
Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHIEV2E study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log10 copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log10 copies/ml and 3.7 log10 copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed. PMID:21813718
International Society for the Advancement of Cytometry Cell Sorter Biosafety Standards
Holmes, Kevin L.; Fontes, Benjamin; Hogarth, Philip; Konz, Richard; Monard, Simon; Pletcher, Charles H.; Wadley, Robert B.; Schmid, Ingrid; Perfetto, Stephen P.
2014-01-01
Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99–117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414–437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment. PMID:24634405
Carey, A.E.; Prudic, David E.
1996-01-01
Documentation is provided of model input and sample output used in a previous report for analysis of ground-water flow and simulated pumping scenarios in Paradise Valley, Humboldt County, Nevada.Documentation includes files containing input values and listings of sample output. The files, in American International Standard Code for Information Interchange (ASCII) or binary format, are compressed and put on a 3-1/2-inch diskette. The decompressed files require approximately 8.4 megabytes of disk space on an International Business Machine (IBM)- compatible microcomputer using the MicroSoft Disk Operating System (MS-DOS) operating system version 5.0 or greater.
X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition
NASA Technical Reports Server (NTRS)
Rolin, T. D.; Leszczuk, Y.
2008-01-01
For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.
Moura, Sidnei; Ultramari, Mariah de Almeida; de Paula, Daniela Mendes Louzada; Yonamine, Mauricio; Pinto, Ernani
2009-04-01
A nuclear magnetic resonance (1H NMR) method for the determination of beta-N-methylamino-L-alanine (L-BMAA) in environmental aqueous samples was developed and validated. L-BMAA is a neurotoxic modified amino acid that can be produced by cyanobacteria in aqueous environments. This toxin was extracted from samples by means of solid-phase extraction (SPE) and identified and quantified by 1H NMR without further derivatization steps. The lower limit of quantification (LLOQ) was 5 microg/mL. Good inter and intra-assay precision was also observed (relative standard deviation <8.5%) with the use of 4-nitro-DL-phenylalanine as an internal standard (IS). This method of 1H NMR analysis is not time consuming and can be readily utilized to monitor L-BMAA and confirm its presence in environmental and biological samples.
Lou, Yu-Chiung; Lin, Chien-Heng; Chen, Chien-Min; Balderrama-Durbin, Christina; Snyder, Douglas K
2016-06-01
The current study examined the psychometric characteristics of the Chinese translation of the Marital Satisfaction Inventory-Revised (MSI-R) in a community sample of 117 couples from Taiwan. The Chinese MSI-R demonstrated moderate to strong internal consistency. Confirmatory factor analysis revealed similar scale factor structures in the Taiwanese and U.S. standardization samples. Mean profile comparisons between the current Taiwanese sample and the original MSI-R standardization sample revealed statistically significant but small differences on several subscales. Overall, the psychometric characteristics of the Chinese MSI-R lend support to its use with couples from diverse cultural backgrounds whose sole or preferred language is Chinese. It may also be appropriate to use the MSI-R in clinical settings for prevention or intervention efforts directed at Chinese-speaking couples. The implications of these findings for clinical and research purposes are discussed. © The Author(s) 2015.
Fulga, Netta
2013-06-01
Quality management and accreditation in the analytical laboratory setting are developing rapidly and becoming the standard worldwide. Quality management refers to all the activities used by organizations to ensure product or service consistency. Accreditation is a formal recognition by an authoritative regulatory body that a laboratory is competent to perform examinations and report results. The Motherisk Drug Testing Laboratory is licensed to operate at the Hospital for Sick Children in Toronto, Ontario. The laboratory performs toxicology tests of hair and meconium samples for research and clinical purposes. Most of the samples are involved in a chain of custody cases. Establishing a quality management system and achieving accreditation became mandatory by legislation for all Ontario clinical laboratories since 2003. The Ontario Laboratory Accreditation program is based on International Organization for Standardization 15189-Medical laboratories-Particular requirements for quality and competence, an international standard that has been adopted as a national standard in Canada. The implementation of a quality management system involves management commitment, planning and staff education, documentation of the system, validation of processes, and assessment against the requirements. The maintenance of a quality management system requires control and monitoring of the entire laboratory path of workflow. The process of transformation of a research/clinical laboratory into an accredited laboratory, and the benefits of maintaining an effective quality management system, are presented in this article.
A low-cost acoustic permeameter
NASA Astrophysics Data System (ADS)
Drake, Stephen A.; Selker, John S.; Higgins, Chad W.
2017-04-01
Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, are fraught with sampling errors, and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. In this paper, we validate acoustically derived permeability of homogenous, reticulated foam samples by comparison with results derived using a standard flow-through permeameter. Acoustic permeameter elements were designed for use in snow, but the measurement methods are not snow-specific. The electronic components - consisting of a signal generator, amplifier, speaker, microphone, and oscilloscope - are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating, but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz, but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10-7 to 3 × 10-9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.
Lichte, F.E.; Meier, A.L.; Crock, J.G.
1987-01-01
A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.
Metal leaching in drinking water domestic distribution system: an Italian case study.
Sorlini, Sabrina; Gialdini, Francesca; Collivignarelli, Carlo
2014-01-01
The objective of this study was to evaluate metal contamination of tap water in seven public buildings in Brescia (Italy). Two monitoring periods were performed using three different sampling methods (overnight stagnation, 30-min stagnation, and random daytime). The results show that the water parameters exceeding the international standards (Directive 98/83/EC) at the tap were lead (max = 363 μg/L), nickel (max = 184 μg/L), zinc (max = 4900 μg/L), and iron (max = 393 μg/L). Compared to the total number of tap water samples analyzed (122), the values higher than limits of Directive 98/83/EC were 17% for lead, 11% for nickel, 14% for zinc, and 7% for iron. Three buildings exceeded iron standard while five buildings exceeded the standard for nickel, lead, and zinc. Moreover, there is no evident correlation between the leaching of contaminants in the domestic distribution system and the age of the pipes while a significant influence is shown by the sampling methods.
The Complete Guide to Training Delivery: A Competency-Based Approach.
ERIC Educational Resources Information Center
King, Stephen B.; King, Marsha; Rothwell, William J.
This guide focuses on 14 instructor competencies identified by the International Board of Standards for Training, Performance, and Instruction. It provides examples, job aids, worksheets, case studies, and sample dialogs and contains actual experiences and critical incidents faced by trainers who participated in the survey study. Strategies to…
Pathways to Suicidal Behaviors in Childhood
ERIC Educational Resources Information Center
Greening, Leilani; Stoppelbein, Laura; Fite, Paula; Dhossche, Dirk; Erath, Stephen; Brown, Jacqueline; Cramer, Robert; Young, Laura
2008-01-01
Path analyses were applied to test a model that includes internalizing and externalizing behavior problems as predictors of suicidal behaviors in children. Parents of an inpatient sample of boys (N = 87; M age = 9.81 years) rated the frequency of suicidal ideation and completed standardized measures of behavior problems. Blind raters rated the…
40 CFR Appendix A to Part 430 - Methods 1650 and 1653
Code of Federal Regulations, 2014 CFR
2014-07-01
... coulometric titration. The method is designed to meet the survey and monitoring requirements of the... designed to meet the survey and monitoring requirements of the Environmental Protection Agency (EPA). 1... different quantitative purposes. The 3,4,5-trichlorophenol sample matrix internal standard (SMIS) is used...
40 CFR Appendix A to Part 430 - Methods 1650 and 1653
Code of Federal Regulations, 2013 CFR
2013-07-01
... coulometric titration. The method is designed to meet the survey and monitoring requirements of the... designed to meet the survey and monitoring requirements of the Environmental Protection Agency (EPA). 1... different quantitative purposes. The 3,4,5-trichlorophenol sample matrix internal standard (SMIS) is used...
The current benchmark method for detecting Cryptosporidium oocysts in water is the U.S. Environmental Protection Agency (U.S. EPA) Method 1623. Studies evaluating this method report that recoveries are highly variable and dependent upon laboratory, water sample, and analyst. Ther...
On the Treatment of Authors, Outliers, and Purchasing Power Parity Exchange Rates.
ERIC Educational Resources Information Center
Jaeger, Richard M.
1993-01-01
Ruth Stott violates canons of scholarly debate by attacking author's October 1992 "Kappan" article on world-class academic standards. Average class size predicted only 10% of variation in 13 year-olds' mean mathematics scores in 14 nations supplying reasonable comprehensive sampling frames for International Assessment of Academic…
1994-06-01
Loeltz, 1964, Evaluation of Hydroeeology and Hydrochemistry of the Truckee Meadow Area. Washoe County. Nevada. U. S. Geological Survey, Water I Supply...was detected in water samples collected from all monitoring wells. A concentration of I 0.055 ppm for the water sample collected from monitoring well...MWO8 during the first round of sampling (MW08-(1)), exceeded the federal drinking water standard of 0.05 ppm. The I background concentration for lead
Determination of benzylpenicillin in pharmaceuticals by capillary zone electrophoresis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoyt, A.M. Jr.; Sepaniak, M.J.
A rapid and direct method is described for the determination of benzylpenicillin (penicillin G) in pharmaceutical preparations. The method involves very little sample preparation and total analysis time for duplicate results is less 30 minutes per sample. The method takes advantage of the speed and separating power of capillary zone electrophoresis (CZE). Detection of penicillin is by absorption at 228 nm. An internal standard is employed to reduce sample injection error. The method was applied successfully to both tablets and injectable preparations. 14 refs., 5 figs., 3 tabs.
Xue, Y J; Pursley, Janice; Arnold, Mark
2007-04-11
BMS-299897 is a gamma-secretase inhibitor that is being developed for the treatment of Alzheimer's disease. Liquid-liquid extraction (LLE), chromatographic/tandem mass spectrometry (LC/MS/MS) methods have been developed and validated for the quantitation of BMS-299897 in human plasma and cerebrospinal fluid (CSF). Both methods utilized (13)C6-BMS-299897, the stable label isotope analog, as the internal standard. For the human plasma extraction method, two incubation steps were required after the addition of 5 mM ammonium acetate and the internal standard in acetonitrile to release the analyte bound to proteins prior to LLE with toluene. For the human CSF extraction method, after the addition of 0.5 N HCl and the internal standard, CSF samples were extracted with toluene and no incubation was required. The organic layers obtained from both extraction methods were removed and evaporated to dryness. The residues were reconstituted and injected into the LC/MS/MS system. Chromatographic separation was achieved isocratically on a MetaChem C18 Hypersil BDS column (2.0 mm x 50 mm, 3 microm). The mobile phase contained 10 mM ammonium acetate pH 5 and acetonitrile. Detection was by negative ion electrospray tandem mass spectrometry. The standard curves ranged from 1 to 1000 ng/ml for human plasma and 0.25-100 ng/ml for human CSF. Both standard curves were fitted to a 1/x weighted quadratic regression model. For both methods, the intra-assay precision was within 8.2% CV, the inter-assay precision was within 5.4% CV, and assay accuracy was within +/-7.4% of the nominal values. The validation and sample analysis results demonstrated that both methods had acceptable precision and accuracy across the calibration ranges.
Engel, Erwan; Ratel, Jérémy
2007-06-22
The objective of the work was to assess the relevance for the authentication of food of a novel chemometric method developed to correct mass spectrometry (MS) data from instrumental drifts, namely, the comprehensive combinatory standard correction (CCSC). Applied to gas chromatography (GC)-MS data, the method consists in analyzing a liquid sample with a mixture of n internal standards and in using the best combination of standards to correct the MS signal provided by each compound. The paper focuses on the authentication of the type of feeding in farm animals based on the composition in volatile constituents of their adipose tissues. The first step of the work enabled on one hand to ensure the feasibility of the conversion of the adipose tissue sample into a liquid phase required for the use of the CCSC method and on the other hand, to determine the key parameters of the extraction of the volatile fraction from this liquid phase by dynamic headspace. The second step showed the relevance of the CCSC pre-processing of the MS fingerprints generated by dynamic headspace-MS analysis of lamb tissues, for the discrimination of animals fed exclusively with pasture (n=8) or concentrate (n=8). When compared with filtering of raw data, internal normalization and correction by a single standard, the CCSC method increased by 17.1-, 3.3- and 1.3-fold, respectively, the number of mass fragments which discriminated the type of feeding. The final step confirmed the advantage of the CCSC pre-processing of dynamic headspace-gas chromatography-MS data for revealing molecular tracers of the type of feeding those number (n=72) was greater when compared to the number of tracers obtained with raw data (n=42), internal normalization (n=63) and correction by a single standard (n=57). The relevance of the information gained by using the CCSC method is discussed.
Doescher, Andrea; Petershofen, Eduard K; Wagner, Franz F; Schunter, Markus; Müller, Thomas H
2013-02-01
Determination of fetal blood groups in maternal plasma samples critically depends on adequate amplification of fetal DNA. We evaluated the routine inclusion of 52 single-nucleotide polymorphisms (SNPs) as internal reference in our polymerase chain reaction (PCR) settings to obtain a positive internal control for fetal DNA. DNA from 223 plasma samples of pregnant women was screened for RHD Exons 3, 4, 5, and 7 in a multiplex PCR including 52 SNPs divided into four primer pools. Amplicons were analyzed by single-base extension and the GeneScan method in a genetic analyzer. Results of D screening were compared to standard RHD genotyping of amniotic fluid or real-time PCR of fetal DNA from maternal plasma. The vast majority of all samples (97.8%) demonstrated differences in maternal and fetal SNP patterns when tested with four primer pools. These differences were not observed in less than 2.2% of the samples most probably due to an extraction failure for adequate amounts of fetal DNA. Comparison of the fetal genotypes with independent results did not reveal a single false-negative case among samples (n = 42) with positive internal control and negative fetal RHD typing. Coamplification of 52 SNPs with RHD-specific sequences for fetal blood group determination introduces a valid positive control for the amplification of fetal DNA to avoid false-negative results. This new approach does not require a paternal blood sample. It may also be applicable to other assays for fetal genotyping in maternal blood samples. © 2012 American Association of Blood Banks.
Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi
2011-12-01
We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.
O. Musaiger, Abdulrahman; Al-Mannai, Mariam; Al-Marzog, Qazi
2014-01-01
Objective: Obesity has become one of the main public health problems worldwide. Childhood obesity rate is growing very fast in both developed and developing countries. This paper aimed to explore the prevalence of overweight and obesity among school children aged 10-13 years in Bahrain, and to find out the difference in this prevalence when using two international standards. Methods: A multistage stratified sampling procedure was used to select 2146 students (1068 males, 1078 females) from public schools in Bahrain. Weight and height were measured and Body Mass Index for age and sex was calculated to determine the obesity levels. Both International Obesity Task Force (IOTF) and World Health Organization (WHO) references were used to determine the prevalence of overweight and obesity. Results: The findings revealed that the prevalence of overweight and obesity ranged from 15.7% to 28.9% among males and from 21.1% to 30.7% among females. The WHO reference standard provided higher prevalence of overweight and obesity than IOTF reference. Conclusion: The study confirmed that obesity is a problem of concern in Bahraini school children and calls for intervention programme to combat obesity in schools. However, the standard used to determine obesity levels should be carefully selected and interpreted. PMID:24948966
Suzuki, Yoshihiro; Endo, Yoko; Ogawa, Masanori; Yamamoto, Shinobu; Takeuchi, Akito; Nakagawa, Tomoo; Onda, Nobuhiko
2009-11-01
N-methyl-2-pyrrolidone (NMP) has been used in many industries and biological monitoring of NMP exposure is preferred to atmospheric monitoring in occupational health. We developed an analytical method that did not include solid phase extraction (SPE) but utilized deuterium-labeled compounds as internal standard for high-performance liquid chromatography-electrospray ionization-mass spectrometry using a C30 column. Urinary concentrations of NMP and its known metabolites 5-hydoxy-N-methyl-2-pyrrolidone (5-HNMP), N-methyl-succinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) were determined in a single run. The method provided baseline separation of these compounds. Their limits of detection in 10-fold diluted urine were 0.0001, 0.006, 0.008, and 0.03 mg/L, respectively. Linear calibration covered a biological exposure index (BEI) for urinary concentration. The within-run and total precisions (CV, %) were 5.6% and 9.2% for NMP, 3.4% and 4.2% for 5-HNMP, 3.7% and 6.0% for MSI, and 6.5% and 6.9% for 2-HMSI. The method was evaluated using international external quality assessment samples, and urine samples from workers exposed to NMP in an occupational area.
Mulloy, B; Heath, A; Behr-Gross, M-E
2007-12-01
An international collaborative study involving fourteen laboratories has taken place, organised by the European Directorate for the Quality of Medicines & HealthCare (EDQM) with National Institute for Biological Standards & Control (NIBSC) (in its capacity as a World Health Organisation (WHO) Laboratory for Biological Standardisation) to provide supporting data for the establishment of replacement batches of Heparin Low-Molecular-Mass (LMM) for Calibration Chemical Reference Substance (CRS), and of the International Reference Reagent (IRR) Low Molecular Weight Heparin for Molecular Weight Calibration. A batch of low-molecular-mass heparin was donated to the organisers and candidate preparations of freeze-dried heparin were produced at NIBSC and EDQM. The establishment study was organised in two phases: a prequalification (phase 1, performed in 3 laboratories in 2005) followed by an international collaborative study (phase 2). In phase 2, started in March 2006, molecular mass parameters were determined for seven different LMM heparin samples using the current CRS batch and two batches of candidate replacement material with a defined number average relative molecular mass (Mn) of 3,700, determined in phase 1. The values calculated using the candidates as standard were systematically different from values calculated using the current batch with its assigned number-average molecular mass (Mna) of 3,700. Using raw data supplied by participants, molecular mass parameters were recalculated using the candidates as standard with values for Mna of 3,800 and 3,900. Values for these parameters agreed more closely with those calculated using the current batch supporting the fact that the candidates, though similar to batch 1 in view of the production processes used, differ slightly in terms of molecular mass distribution. Therefore establishment of the candidates was recommended with an assigned Mna value of 3,800 that is both consistent with phase 1 results and guarantees continuity with the current CRS batch. In phase 2, participants also determined molecular weight parameters for the seven different LMM heparin samples using both the 1st IRR (90/686) and its Broad Standard Table and the candidate World Health Organization (WHO) 2nd International Standard (05/112) (2nd IS) using a Broad Standard Table established in phase 1. Mean molecular weights calculated using 2nd IS were slightly higher than with 1st IRR, and participants in the study indicated that this systematic difference precluded establishment of 2nd IS with the table supplied. A replacement Broad Standard Table has been devised on the basis of the central recalculations of raw data supplied by participants; this table gives improved agreement between values derived using the 1st IRR and the candidate 2nd IS. On the basis of this study a recommendation was made for the establishment of 2nd IS and its proposed Broad Standard Table as a replacement for the 1st International Reference Reagent Low Molecular Weight Heparin for Molecular Weight Calibration. Unlike the 1st IRR however, the candidate material 2nd IS is not suitable for use with the method of Nielsen. The candidate materials were established as heparin low-molecular-mass for calibration batches 2 and 3 by the Ph. Eur. Commission in March 2007 and as 2nd IS low-molecular-weight heparin for molecular weight calibration (05/112) by the Expert Committee on Biological Standardization in November 2007.
NASA Technical Reports Server (NTRS)
Gaier, James R.; Berkebile, Stephen; Sechkar, Edward A.; Panko, Scott R.
2012-01-01
The preliminary design of a testbed to evaluate the effectiveness of galactic cosmic ray (GCR) shielding materials, the MISSE Radiation Shielding Testbed (MRSMAT) is presented. The intent is to mount the testbed on the Materials International Space Station Experiment-X (MISSE-X) which is to be mounted on the International Space Station (ISS) in 2016. A key feature is the ability to simultaneously test nine samples, including standards, which are 5.25 cm thick. This thickness will enable most samples to have an areal density greater than 5 g/sq cm. It features a novel and compact GCR telescope which will be able to distinguish which cosmic rays have penetrated which shielding material, and will be able to evaluate the dose transmitted through the shield. The testbed could play a pivotal role in the development and qualification of new cosmic ray shielding technologies.
Enumerating Sparse Organisms in Ships’ Ballast Water: Why Counting to 10 Is Not So Easy
2011-01-01
To reduce ballast water-borne aquatic invasions worldwide, the International Maritime Organization and United States Coast Guard have each proposed discharge standards specifying maximum concentrations of living biota that may be released in ships’ ballast water (BW), but these regulations still lack guidance for standardized type approval and compliance testing of treatment systems. Verifying whether BW meets a discharge standard poses significant challenges. Properly treated BW will contain extremely sparse numbers of live organisms, and robust estimates of rare events require extensive sampling efforts. A balance of analytical rigor and practicality is essential to determine the volume of BW that can be reasonably sampled and processed, yet yield accurate live counts. We applied statistical modeling to a range of sample volumes, plankton concentrations, and regulatory scenarios (i.e., levels of type I and type II errors), and calculated the statistical power of each combination to detect noncompliant discharge concentrations. The model expressly addresses the roles of sampling error, BW volume, and burden of proof on the detection of noncompliant discharges in order to establish a rigorous lower limit of sampling volume. The potential effects of recovery errors (i.e., incomplete recovery and detection of live biota) in relation to sample volume are also discussed. PMID:21434685
Enumerating sparse organisms in ships' ballast water: why counting to 10 is not so easy.
Miller, A Whitman; Frazier, Melanie; Smith, George E; Perry, Elgin S; Ruiz, Gregory M; Tamburri, Mario N
2011-04-15
To reduce ballast water-borne aquatic invasions worldwide, the International Maritime Organization and United States Coast Guard have each proposed discharge standards specifying maximum concentrations of living biota that may be released in ships' ballast water (BW), but these regulations still lack guidance for standardized type approval and compliance testing of treatment systems. Verifying whether BW meets a discharge standard poses significant challenges. Properly treated BW will contain extremely sparse numbers of live organisms, and robust estimates of rare events require extensive sampling efforts. A balance of analytical rigor and practicality is essential to determine the volume of BW that can be reasonably sampled and processed, yet yield accurate live counts. We applied statistical modeling to a range of sample volumes, plankton concentrations, and regulatory scenarios (i.e., levels of type I and type II errors), and calculated the statistical power of each combination to detect noncompliant discharge concentrations. The model expressly addresses the roles of sampling error, BW volume, and burden of proof on the detection of noncompliant discharges in order to establish a rigorous lower limit of sampling volume. The potential effects of recovery errors (i.e., incomplete recovery and detection of live biota) in relation to sample volume are also discussed.
DeVries, Jonathan W; Silvera, Karlene R; McSherry, Elliot; Dowell, Dawn
2012-01-01
During the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," held on June 29, 2011, an Expert Review Panel (ERP) reviewed the method for the "Determination of Vitamins A (Retinol) and E (alpha-Tocopherol) in Foods by Liquid Chromatography: Collaborative Study," published by Jonathan W. DeVries and Karlene R. Silvera in J. AOAC Int. in 2002. After evaluation of the original validation data, an ERP agreed in June 2011 that the method meets standard method performance requirements (SMPRs) for vitamin A, as articulated by the Stakeholder Panel on Infant Formula and Adult Nutritionals. The ERP granted the method First Action status, applicable to determining vitamin A in ready-to-eat infant and adult nutritional formula. In an effort to achieve Final Action status, it was recommended that additional information be generated for different types of infant and adult nutritional formula matrixes at varied concentration levels as indicated in the vitamin A (retinol) SMPR. Existing AOAC LC methods are suited for specific vitamin A analytical applications. The original method differs from existing methods in that it can be used to assay samples in all nine sectors of the food matrix. One sector of the food matrix was powdered infant formula and gave support for the First Action approval for vitamin A in infant and adult nutritional formula. In this method, standards and test samples are saponified in basic ethanol-water solution, neutralized, and diluted, converting fats to fatty acids and retinol esters to retinol. Retinol is quantitated by an LC method, using UV detection at 313 or 328 nm for retinol. Vitamin concentration is calculated by comparison of the peak heights or peak areas of retinol in test samples with those of standards.
Quality assured measurements of animal building emissions: odor concentrations.
Jacobson, Larry D; Hetchler, Brian P; Schmidt, David R; Nicolai, Richard E; Heber, Albert J; Ni, Ji-Qin; Hoff, Steven J; Koziel, Jacek A; Zhang, Yuanhui; Beasley, David B; Parker, David B
2008-06-01
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.
The new ISO 6579-1: A real horizontal standard for detection of Salmonella, at last!
Mooijman, Kirsten A
2018-05-01
Up to 2016, three international standard methods existed for the detection of Salmonella spp. in food, animal feed and samples from the primary production stage: ISO 6785:2001 for milk and milk products, ISO 6579:2002 for (other) food and animal feed and Annex D of ISO 6579:2007 for samples from the primary production stage. In 2009, an ISO/CEN working group started with the revision of ISO 6579:2002 with two main aims: combining the three aforementioned standards in one document and improving the information in ISO 6579:2002. Additionally it was decided to split ISO 6579 into three parts, where part 1 describes the detection, part 2 the enumeration by mini-MPN (published in 2012) and part 3 the serotyping of Salmonella (published in 2014). This paper describes the experiments and choices made for improving the part on detection of Salmonella (ISO 6579-1). The final voting stage on (draft) ISO 6579-1 was finished by the end of December 2016, with a positive outcome. Finally, a real horizontal standard became available for detection of Salmonella in food, animal feed, environmental samples in the area of food production and food handling and in samples from the primary production stage in 2017. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Krogh, E.; Gill, C.; Bell, R.; Davey, N.; Martinsen, M.; Thompson, A.; Simpson, I. J.; Blake, D. R.
2012-12-01
The release of hydrocarbons into the environment can have significant environmental and economic consequences. The evolution of smaller, more portable mass spectrometers to the field can provide spatially and temporally resolved information for rapid detection, adaptive sampling and decision support. We have deployed a mobile platform membrane introduction mass spectrometer (MIMS) for the in-field simultaneous measurement of volatile and semi-volatile organic compounds. In this work, we report instrument and data handling advances that produce geographically referenced data in real-time and preliminary data where these improvements have been combined with high precision ultra-trace VOCs analysis to adaptively sample air plumes near oil and gas operations in Alberta, Canada. We have modified a commercially available ion-trap mass spectrometer (Griffin ICX 400) with an in-house temperature controlled capillary hollow fibre polydimethylsiloxane (PDMS) polymer membrane interface and in-line permeation tube flow cell for a continuously infused internal standard. The system is powered by 24 VDC for remote operations in a moving vehicle. Software modifications include the ability to run continuous, interlaced tandem mass spectrometry (MS/MS) experiments for multiple contaminants/internal standards. All data are time and location stamped with on-board GPS and meteorological data to facilitate spatial and temporal data mapping. Tandem MS/MS scans were employed to simultaneously monitor ten volatile and semi-volatile analytes, including benzene, toluene, ethylbenzene and xylene (BTEX), reduced sulfur compounds, halogenated organics and naphthalene. Quantification was achieved by calibrating against a continuously infused deuterated internal standard (toluene-d8). Time referenced MS/MS data were correlated with positional data and processed using Labview and Matlab to produce calibrated, geographical Google Earth data-visualizations that enable adaptive sampling protocols. This real-time approach has been employed in a moving vehicle to identify and track downwind plumes of fugitive VOC emissions near hydrocarbon upgrading and chemical processing facilities in Fort Saskatchewan, Alberta. This information was relayed to a trailing vehicle, which collected stationary grab samples in evacuated canisters for ultra trace analysis of over seventy VOC analytes. In addition, stationary time series data were collected and compared with grab samples co-located with our sampling line. Spatially and temporally resolved, time referenced MS/MS data for several air contaminants associated with oil and gas processing were processed in real time to produce geospatial data for visualization in Google Earth. This information was used to strategically locate grab samples for high precision, ultra trace analysis.
Srivastava, Praveen; Moorthy, Ganesh S; Gross, Robert; Barrett, Jeffrey S
2013-01-01
A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and ¹³C₆-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (¹³C₆-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0-2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100-111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03-9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2-108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients.
Fort Ord Groundwater Remediation Studies, 2002 - 2005
2006-08-01
Groundwater was also directly sampled from a well OU1-36 with a bailer using an acid - cleaned bailer to determine whether comparable levels of trace...collected for the analysis of total chromium. The total chromium and Cr(VI) samples were collected in acid -clean low density polyethylene (LDPE) bottles...and 69Ga to be used as an internal standard. Acetic acid /ammonia buffer solution was prepared by slow addition of 15 mL of aqueous ammonia (20–22
Pretorius, Carel J; McWhinney, Brett C; Sipinkoski, Bilyana; Wilce, Alice; Cox, David; McWhinney, Avis; Ungerer, Jacobus P J
2018-03-01
We optimized a quantitative amino acid method with pre-column derivatization, norvaline (nva) internal standard and reverse phase ultra-performance liquid chromatography by replacing the ultraviolet detector with a single quadrupole mass spectrometer (MS nva ). We used 13 C 15 N isotopically labeled amino acid internal standards and a C18 column with 1.6μm particles to optimize the chromatography and to confirm separation of isobaric compounds (MS lis ). We compared the analytical performance of MS nva with MS lis and the original method (UV nva ) with clinical samples. The chromatography time per sample of MS nva was 8min, detection capabilities were <1μmol/L for most components, intermediate imprecisions at low concentrations were <10% and there was negligible carryover. MS nva was linear up to a total amino acid concentration in a sample of approximately 9500μmol/L. The agreements between most individual amino acids were satisfactory compared to UV nva with the latter prone to outliers and suboptimal quantitation of urinary arginine, aspartate, glutamate and methionine. MS nva reliably detected argnininosuccinate, β-alanine, citrulline and cysteine-s-sulfate. MS nva resulted in a more than fivefold increase in operational efficiency with accurate detection of amino acids and metabolic intermediates in clinical samples. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Aguas, Patricia C; Fitzhenry, Matthew J; Giannikopoulos, Georgina; Varelis, Peter
2006-08-01
An accurate and precise method for the quantification of acrylamide using stable isotope dilution liquid chromatography-tandem mass spectrometry was developed and used to measure acrylamide in coffee and cocoa samples. The sample preparation involved extraction of the analyte and its internal standard, 13C3-acrylamide, into water and subsequent defatting of the aqueous extract with dichloromethane. An aliquot of the resulting aqueous extract was then azeotropically dried under reduced pressure and subsequently purified using an aminopropyl-bonded silica cartridge. The purified extracts were then chromatographed on a 5-microm 2.1 x 150 mm Hypercarb column, the effluent of which was monitored for the analyte and its internal standard using positive-ion APCI-selected reaction monitoring. The intra-laboratory reproducibility of the method, expressed as a relative coefficient of variation (%, n=5), was determined at four levels of concentration (12.3, 42.3, 139.3 and 464.8 microg kg(-1)) and was found to vary between 0.6-2.5%. The accuracy of the method was assessed using a reference sample of coffee. The average result obtained using our method differed from the assigned value of the reference material by less than 1%. An analysis of a cocoa sample revealed that the method is capable of precisely estimating acrylamide in challenging matrices down to a level of at least 12.3 microg kg(-1).
Standardization for oxygen isotope ratio measurement - still an unsolved problem.
Kornexl; Werner; Gehre
1999-07-01
Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.
Szulc, P; Naylor, K; Hoyle, N R; Eastell, R; Leary, E T
2017-09-01
The National Bone Health Alliance (NBHA) recommends standardized sample handling and patient preparation for C-terminal telopeptide of type I collagen (CTX-I) and N-terminal propeptide of type I procollagen (PINP) measurements to reduce pre-analytical variability. Controllable and uncontrollable patient-related factors are reviewed to facilitate interpretation and minimize pre-analytical variability. The IOF and the International Federation of Clinical Chemistry (IFCC) Bone Marker Standards Working Group have identified PINP and CTX-I in blood to be the reference markers of bone turnover for the fracture risk prediction and monitoring of osteoporosis treatment. Although used in clinical research for many years, bone turnover markers (BTM) have not been widely adopted in clinical practice primarily due to their poor within-subject and between-lab reproducibility. The NBHA Bone Turnover Marker Project team aim to reduce pre-analytical variability of CTX-I and PINP measurements through standardized sample handling and patient preparation. Recommendations for sample handling and patient preparations were made based on review of available publications and pragmatic considerations to reduce pre-analytical variability. Controllable and un-controllable patient-related factors were reviewed to facilitate interpretation and sample collection. Samples for CTX-I must be collected consistently in the morning hours in the fasted state. EDTA plasma is preferred for CTX-I for its greater sample stability. Sample collection conditions for PINP are less critical as PINP has minimal circadian variability and is not affected by food intake. Sample stability limits should be observed. The uncontrollable aspects (age, sex, pregnancy, immobility, recent fracture, co-morbidities, anti-osteoporotic drugs, other medications) should be considered in BTM interpretation. Adopting standardized sample handling and patient preparation procedures will significantly reduce controllable pre-analytical variability. The successful adoption of such recommendations necessitates the close collaboration of various stakeholders at the global stage, including the laboratories, the medical community, the reagent manufacturers and the regulatory agencies.
Approaches to quality management and accreditation in a genetic testing laboratory
Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth
2010-01-01
Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559
International Standards for Genomes, Transcriptomes, and Metagenomes
Mason, Christopher E.; Afshinnekoo, Ebrahim; Tighe, Scott; Wu, Shixiu; Levy, Shawn
2017-01-01
Challenges and biases in preparing, characterizing, and sequencing DNA and RNA can have significant impacts on research in genomics across all kingdoms of life, including experiments in single-cells, RNA profiling, and metagenomics (across multiple genomes). Technical artifacts and contamination can arise at each point of sample manipulation, extraction, sequencing, and analysis. Thus, the measurement and benchmarking of these potential sources of error are of paramount importance as next-generation sequencing (NGS) projects become more global and ubiquitous. Fortunately, a variety of methods, standards, and technologies have recently emerged that improve measurements in genomics and sequencing, from the initial input material to the computational pipelines that process and annotate the data. Here we review current standards and their applications in genomics, including whole genomes, transcriptomes, mixed genomic samples (metagenomes), and the modified bases within each (epigenomes and epitranscriptomes). These standards, tools, and metrics are critical for quantifying the accuracy of NGS methods, which will be essential for robust approaches in clinical genomics and precision medicine. PMID:28337071
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoegg, Edward D.; Marcus, R. Kenneth; Hager, George J.
RATIONALE: The field of highly accurate and precise isotope ratio (IR) analysis has been dominated by inductively coupled plasma and thermal ionization mass spectrometers. While these instruments are considered the gold standard for IR analysis, the International Atomic Energy Agency desires a field deployable instrument capable of accurately and precisely measuring U isotope ratios. METHODS: The proposed system interfaces the liquid sampling – atmospheric pressure glow discharge (LS-APGD) ion source with a high resolution Exactive Orbitrap mass spectrometer. With this experimental setup certified U isotope standards and unknown samples were analyzed. The accuracy and precision of the system were thenmore » determined. RESULTS: The LS-APGD /Exactive instrument measures a certified reference material of natural U (235U/238U = 0.007258) as 0.007041 with a relative standard deviation of 0.158% meeting the International Target Values for Uncertainty for the destructive analysis of U. Additionally, when three unknowns measured and compared to the results from an ICP multi collector instrument, there is no statistical difference between the two instruments.CONCLUSIONS: The LS-APGD / Orbitrap system, while still in the preliminary stages of development, offers highly accurate and precise IR analysis that suggest a paradigm shift in the world of IR analysis. Furthermore, the portability of the LS-APGD as an elemental ion source combined with the low overhead and small size of the Orbitrap suggest that the instrumentation is capable of being field deployable.With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.« less
Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine
2012-08-31
Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012 Elsevier B.V. All rights reserved.
Gao, Yangyang; Chen, Junying; Zhang, Xiqian; Xie, Huiru; Wang, Yanran; Guo, Shuquan
2017-03-01
An LC-MS/MS method for the determination of polyaspartate paclitaxel conjugate (PASP-PTX) and paclitaxel (PTX) in dog plasma with cephalomannine (Internal Standard for PASP-PTX, IS-I) and clopidogrel bisulfate (Internal Standard for PTX, IS-II) as the internal standards was developed and validated. Plasma samples of PASP-PTX were extracted by ethyl acetate following the hydrolysis reaction, while protein precipitation was used for the extraction of PTX using acetonitrile. Analytes were separated by a CAPCELL PAK C18 MG II column using a gradient elution with the mobile phase (A) 5 mM ammonium containing 0.1% formic acid, and (B) acetonitrile. Quantification was performed by monitoring the m/z transitions of 286.2/105.0 for PASP-PTX, 264.2/83.0 for IS-I, 854.4/286.0 for PTX, and 322.1/184.1 for IS-II in the ESI positive mode. This method was validated in terms of specificity, linearity, precision, accuracy, and stability. The lower limit of quantification was 0.15 µg/mL for PASP-PTX and 0.01 µg/mL for PTX, and the calibration curves were linear over 0.15-300 µg/mL for PASP-PTX and over 0.01-10 µg/mL for PTX. The samples were stable under all the tested conditions. The method was successfully applied to study the pharmacokinetic profiles of PASP-PTX and PTX in beagles following intravenous administration of PASP-PTX. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhang, Xiaotao; Hou, Hongwei; Chen, Huan; Liu, Yong; Wang, An; Hu, Qingyuan
2015-09-17
A stable isotope dilution liquid chromatography with tandem mass spectrometry method for the analysis of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate was developed and validated. Compared with previously reported methods, this method has lower limits of detection (0.04-1.35 ng/cig). Additionally, the proposed method saves time, reduces the number of separation steps, and reduces the quantity of solvent needed. The new method was applied to evaluate polycyclic aromatic hydrocarbon content in 213 commercially available cigarettes in China, under the International Standardization Organization smoking regime and the Health Canadian intense smoking regime. The results showed that the total polycyclic aromatic hydrocarbon content was more than two times higher in samples from the Health Canadian intense smoking regime than in samples from the International Standardization Organization smoking regime (1189.23 vs. 2859.50 ng/cig, p<0.05). Meanwhile, the concentration of individual polycyclic aromatic hydrocarbons (and total polycyclic aromatic hydrocarbons) increased with labeled tar content in both of the tested smoking regimes. There was a positive correlation between total polycyclic aromatic hydrocarbons under the International Standardization Organization smoking regime with that under the Health Canadian intense smoking regime. The proposed liquid chromatography with tandem mass spectrometry method is satisfactory for the rapid, sensitive, and accurately quantitative evaluation of polycyclic aromatic hydrocarbon content in cigarette smoke condensate, and it can be applied to assess potential health risks from smoking. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Kristensen, Anne F; Kristensen, Søren R; Falkmer, Ursula; Münster, Anna-Marie B; Pedersen, Shona
2018-05-01
The Calibrated Automated Thrombography (CAT) is an in vitro thrombin generation (TG) assay that holds promise as a valuable tool within clinical diagnostics. However, the technique has a considerable analytical variation, and we therefore, investigated the analytical and between-subject variation of CAT systematically. Moreover, we assess the application of an internal standard for normalization to diminish variation. 20 healthy volunteers donated one blood sample which was subsequently centrifuged, aliquoted and stored at -80 °C prior to analysis. The analytical variation was determined on eight runs, where plasma from the same seven volunteers was processed in triplicates, and for the between-subject variation, TG analysis was performed on plasma from all 20 volunteers. The trigger reagents used for the TG assays included both PPP reagent containing 5 pM tissue factor (TF) and PPPlow with 1 pM TF. Plasma, drawn from a single donor, was applied to all plates as an internal standard for each TG analysis, which subsequently was used for normalization. The total analytical variation for TG analysis performed with PPPlow reagent is 3-14% and 9-13% for PPP reagent. This variation can be minimally reduced by using an internal standard but mainly for ETP (endogenous thrombin potential). The between-subject variation is higher when using PPPlow than PPP and this variation is considerable higher than the analytical variation. TG has a rather high inherent analytical variation but considerable lower than the between-subject variation when using PPPlow as reagent.
Choi, Daewoong; Gong, Yongdeuk; Nam, Sang-Ho; Han, Song-Hee; Yoo, Jonghyun; Lee, Yonghoon
2014-01-01
We report an approach for selecting an internal standard to improve the precision of laser-induced breakdown spectroscopy (LIBS) analysis for determining calcium (Ca) concentration in water. The dissolved Ca(2+) ions were pre-concentrated on filter paper by evaporating water. The filter paper was dried and analyzed using LIBS. By adding strontium chloride to sample solutions and using a Sr II line at 407.771 nm for the intensity normalization of Ca II lines at 393.366 or 396.847 nm, the analysis precision could be significantly improved. The Ca II and Sr II line intensities were mapped across the filter paper, and they showed a strong positive shot-to-shot correlation with the same spatial distribution on the filter paper surface. We applied this analysis approach for the measurement of Ca(2+) in tap, bottled, and ground water samples. The Ca(2+) concentrations determined using LIBS are in good agreement with those obtained from flame atomic absorption spectrometry. Finally, we suggest a homologous relation of the strongest emission lines of period 4 and 5 elements in groups IA and IIA based on their similar electronic structures. Our results indicate that the LIBS can be effectively applied for liquid analysis at the sub-parts per million level with high precision using a simple drying of liquid solutions on filter paper and the use of the correct internal standard elements with the similar valence electronic structure with respect to the analytes of interest.
Liu, Yu-Qi; Wang, Yue-Xi; Shi, Nan-Nan; Han, Xue-Jie; Lu, Ai-Ping
2017-05-01
To review the current situation and progress of traditional Chinese medicine (TCM) international standards, standard projects and proposals in International Organization for Standardization (ISO)/ technical committee (TC) 249. ISO/TC 249 standards and standard projects on the ISO website were searched and new standard proposals information were collected from ISO/TC 249 National Mirror Committee in China. Then all the available data were summarized in 5 closely related items, including proposed time, proposed country, assigned working group (WG), current stage and classifification. In ISO/TC 249, there were 2 international standards, 18 standard projects and 24 new standard proposals proposed in 2014. These 44 standard subjects increased year by year since 2011. Twenty-nine of them were proposed by China, 15 were assigned to WG 4, 36 were in preliminary and preparatory stage and 8 were categorized into 4 fifields, 7 groups and sub-groups based on International Classifification Standards. A rapid and steady development of international standardization in TCM can be observed in ISO/TC 249.
Examining the Influence of Educational Mobile Application Software on Students' Technology Literacy
ERIC Educational Resources Information Center
Twu, Ming-Lii
2017-01-01
The purpose of this mixed methods study was to employ the International Society for Technology in Education (ISTE) Standards for Students as taxonomy to classify educational mobile application (app) software into seven categories and empirically examine the influence on students' technology literacy. A purposeful sample of fifth grade core subject…
ERIC Educational Resources Information Center
Moradi, Bonnie; Rottenstein, Adena
2007-01-01
This study examined the generalizability of direct and mediated links posited in objectification theory among internalization of sociocultural standards of beauty, body surveillance, body shame, and eating disorder symptoms with a sample of Deaf women. The study also examined the role of marginal Deaf cultural identity attitudes within this…
NASA Astrophysics Data System (ADS)
Paulo, Joao A.; Navarrete-Perea, Jose; Erickson, Alison R.; Knott, Jeffrey; Gygi, Steven P.
2018-04-01
Phosphorylation-mediated signaling pathways have major implications in cellular regulation and disease. However, proteins with roles in these pathways are frequently less abundant and phosphorylation is often sub-stoichiometric. As such, the efficient enrichment, and subsequent recovery of phosphorylated peptides, is vital. Mass spectrometry-based proteomics is a well-established approach for quantifying thousands of phosphorylation events in a single experiment. We designed a peptide internal standard-based assay directed toward sample preparation strategies for mass spectrometry analysis to understand better phosphopeptide recovery from enrichment strategies. We coupled mass-differential tandem mass tag (mTMT) reagents (specifically, TMTzero and TMTsuper-heavy), nine mass spectrometry-amenable phosphopeptides (phos9), and peak area measurements from extracted ion chromatograms to determine phosphopeptide recovery. We showcase this mTMT/phos9 recovery assay by evaluating three phosphopeptide enrichment workflows. Our assay provides data on the recovery of phosphopeptides, which complement other metrics, namely the number of identified phosphopeptides and enrichment specificity. Our mTMT/phos9 assay is applicable to any enrichment protocol in a typical experimental workflow irrespective of sample origin or labeling strategy. [Figure not available: see fulltext.
Percy, Andrew J; Yang, Juncong; Hardie, Darryl B; Chambers, Andrew G; Tamura-Wells, Jessica; Borchers, Christoph H
2015-06-15
Spurred on by the growing demand for panels of validated disease biomarkers, increasing efforts have focused on advancing qualitative and quantitative tools for more highly multiplexed and sensitive analyses of a multitude of analytes in various human biofluids. In quantitative proteomics, evolving strategies involve the use of the targeted multiple reaction monitoring (MRM) mode of mass spectrometry (MS) with stable isotope-labeled standards (SIS) used for internal normalization. Using that preferred approach with non-invasive urine samples, we have systematically advanced and rigorously assessed the methodology toward the precise quantitation of the largest, multiplexed panel of candidate protein biomarkers in human urine to date. The concentrations of the 136 proteins span >5 orders of magnitude (from 8.6 μg/mL to 25 pg/mL), with average CVs of 8.6% over process triplicate. Detailed here is our quantitative method, the analysis strategy, a feasibility application to prostate cancer samples, and a discussion of the utility of this method in translational studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Ajtony, Zsolt; Laczai, Nikoletta; Dravecz, Gabriella; Szoboszlai, Norbert; Marosi, Áron; Marlok, Bence; Streli, Christina; Bencs, László
2016-12-15
HR-CS-GFAAS methods were developed for the fast determination of Cu in domestic and commercially available Hungarian distilled alcoholic beverages (called pálinka), in order to decide if their Cu content exceeds the permissible limit, as legislated by the WHO. Some microliters of samples were directly dispensed into the atomizer. Graphite furnace heating programs, effects/amounts of the Pd modifier, alternative wavelengths (e.g., Cu I 249.2146nm), external calibration and internal standardization methods were studied. Applying a fast graphite furnace heating program without any chemical modifier, the Cu content of a sample could be quantitated within 1.5min. The detection limit of the method is 0.03mg/L. Calibration curves are linear up to 10-15mg/L Cu. Spike-recoveries ranged from 89% to 119% with an average of 100.9±8.5%. Internal calibration could be applied with the assistance of Cr, Fe, and/or Rh standards. The accuracy of the GFAAS results was verified by TXRF analyses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Richards-Kortum, Rebecca
2015-01-01
It was recently demonstrated that recombinase polymerase amplification (RPA), an isothermal amplification platform for pathogen detection, may be used to quantify DNA sample concentration using a standard curve. In this manuscript, a detailed protocol for developing and implementing a real-time quantitative recombinase polymerase amplification assay (qRPA assay) is provided. Using HIV-1 DNA quantification as an example, the assembly of real-time RPA reactions, the design of an internal positive control (IPC) sequence, and co-amplification of the IPC and target of interest are all described. Instructions and data processing scripts for the construction of a standard curve using data from multiple experiments are provided, which may be used to predict the concentration of unknown samples or assess the performance of the assay. Finally, an alternative method for collecting real-time fluorescence data with a microscope and a stage heater as a step towards developing a point-of-care qRPA assay is described. The protocol and scripts provided may be used for the development of a qRPA assay for any DNA target of interest. PMID:25867513
Crannell, Zachary A; Rohrman, Brittany; Richards-Kortum, Rebecca
2015-03-30
It was recently demonstrated that recombinase polymerase amplification (RPA), an isothermal amplification platform for pathogen detection, may be used to quantify DNA sample concentration using a standard curve. In this manuscript, a detailed protocol for developing and implementing a real-time quantitative recombinase polymerase amplification assay (qRPA assay) is provided. Using HIV-1 DNA quantification as an example, the assembly of real-time RPA reactions, the design of an internal positive control (IPC) sequence, and co-amplification of the IPC and target of interest are all described. Instructions and data processing scripts for the construction of a standard curve using data from multiple experiments are provided, which may be used to predict the concentration of unknown samples or assess the performance of the assay. Finally, an alternative method for collecting real-time fluorescence data with a microscope and a stage heater as a step towards developing a point-of-care qRPA assay is described. The protocol and scripts provided may be used for the development of a qRPA assay for any DNA target of interest.
Protein quantification using a cleavable reporter peptide.
Duriez, Elodie; Trevisiol, Stephane; Domon, Bruno
2015-02-06
Peptide and protein quantification based on isotope dilution and mass spectrometry analysis are widely employed for the measurement of biomarkers and in system biology applications. The accuracy and reliability of such quantitative assays depend on the quality of the stable-isotope labeled standards. Although the quantification using stable-isotope labeled peptides is precise, the accuracy of the results can be severely biased by the purity of the internal standards, their stability and formulation, and the determination of their concentration. Here we describe a rapid and cost-efficient method to recalibrate stable isotope labeled peptides in a single LC-MS analysis. The method is based on the equimolar release of a protein reference peptide (used as surrogate for the protein of interest) and a universal reporter peptide during the trypsinization of a concatenated polypeptide standard. The quality and accuracy of data generated with such concatenated polypeptide standards are highlighted by the quantification of two clinically important proteins in urine samples and compared with results obtained with conventional stable isotope labeled reference peptides. Furthermore, the application of the UCRP standards in complex samples is described.
Deans, Zandra C; Costa, Jose Luis; Cree, Ian; Dequeker, Els; Edsjö, Anders; Henderson, Shirley; Hummel, Michael; Ligtenberg, Marjolijn Jl; Loddo, Marco; Machado, Jose Carlos; Marchetti, Antonio; Marquis, Katherine; Mason, Joanne; Normanno, Nicola; Rouleau, Etienne; Schuuring, Ed; Snelson, Keeda-Marie; Thunnissen, Erik; Tops, Bastiaan; Williams, Gareth; van Krieken, Han; Hall, Jacqueline A
2017-01-01
The clinical demand for mutation detection within multiple genes from a single tumour sample requires molecular diagnostic laboratories to develop rapid, high-throughput, highly sensitive, accurate and parallel testing within tight budget constraints. To meet this demand, many laboratories employ next-generation sequencing (NGS) based on small amplicons. Building on existing publications and general guidance for the clinical use of NGS and learnings from germline testing, the following guidelines establish consensus standards for somatic diagnostic testing, specifically for identifying and reporting mutations in solid tumours. These guidelines cover the testing strategy, implementation of testing within clinical service, sample requirements, data analysis and reporting of results. In conjunction with appropriate staff training and international standards for laboratory testing, these consensus standards for the use of NGS in molecular pathology of solid tumours will assist laboratories in implementing NGS in clinical services.
International standardisation work on the measurement of radon in air and water.
Calmet, D; Ameon, R; Beck, T; Bombard, A; Bourquin, M N; Brun, S; De Jong, P; Forte, M; Fournier, M; Herranz, M; Jerome, S; Klett, A; Kwakman, P; Llaurado, M; Loyen, J; Michel, R; Nardoux, P; Richards, T; Schuler, C; Tokonami, S; Woods, M
2011-05-01
Radon is considered to be the main source of human exposure to natural radiation. As stated by the World Health Organization, the exposure due to the inhalation of indoor radon is much greater than the one via the ingestion of water as radon degasses from water during handling. In response to these concerns about the universal presence of radon, environmental assessment studies are regularly commissioned to assess the radon exposure of public and workers. The credibility of such studies relies on the quality and reliability of radon analysis as well as on the sample representativeness of the radiological situation. The standard-setting approach, based on consensus, seemed to lend itself to a settlement of technical aspects of potential comparison. At present, two Working Groups of the International Standardization Organization are focussing on drafting standards on radon and its decay products measurement in air and water. These standards, which aim for a set of rigorous metrology practices, will be useful for persons in charge of the initial characterisation of a site with respect to natural radioactivity as well as to those performing the routine surveillance of specific sites.
NASA Astrophysics Data System (ADS)
Tian, Lunfu; Wang, Lili; Gao, Wei; Weng, Xiaodong; Liu, Jianhui; Zou, Deshuang; Dai, Yichun; Huang, Shuke
2018-03-01
For the quantitative analysis of the principal elements in lead-antimony-tin alloys, directly X-ray fluorescence (XRF) method using solid metal disks introduces considerable errors due to the microstructure inhomogeneity. To solve this problem, an aqueous solution XRF method is proposed for determining major amounts of Sb, Sn, Pb in lead-based bearing alloys. The alloy samples were dissolved by a mixture of nitric acid and tartaric acid to eliminated the effects of microstructure of these alloys on the XRF analysis. Rh Compton scattering was used as internal standard for Sb and Sn, and Bi was added as internal standard for Pb, to correct for matrix effects, instrumental and operational variations. High-purity lead, antimony and tin were used to prepare synthetic standards. Using these standards, calibration curves were constructed for the three elements after optimizing the spectrometer parameters. The method has been successfully applied to the analysis of lead-based bearing alloys and is more rapid than classical titration methods normally used. The determination results are consistent with certified values or those obtained by titrations.
Rudzki, Piotr J; Gniazdowska, Elżbieta; Buś-Kwaśnik, Katarzyna
2018-06-05
Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful tool for studying pharmacokinetics and toxicokinetics. Reliable bioanalysis requires the characterization of the matrix effect, i.e. influence of the endogenous or exogenous compounds on the analyte signal intensity. We have compared two methods for the quantitation of matrix effect. The CVs(%) of internal standard normalized matrix factors recommended by the European Medicines Agency were evaluated against internal standard normalized relative matrix effects derived from Matuszewski et al. (2003). Both methods use post-extraction spiked samples, but matrix factors require also neat solutions. We have tested both approaches using analytes of diverse chemical structures. The study did not reveal relevant differences in the results obtained with both calculation methods. After normalization with the internal standard, the CV(%) of the matrix factor was on average 0.5% higher than the corresponding relative matrix effect. The method adopted by the European Medicines Agency seems to be slightly more conservative in the analyzed datasets. Nine analytes of different structures enabled a general overview of the problem, still, further studies are encouraged to confirm our observations. Copyright © 2018 Elsevier B.V. All rights reserved.
Bohnert, Sara; Vair, Cory; Mikler, John
2010-05-15
A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.
International Society for the Advancement of Cytometry cell sorter biosafety standards.
Holmes, Kevin L; Fontes, Benjamin; Hogarth, Philip; Konz, Richard; Monard, Simon; Pletcher, Charles H; Wadley, Robert B; Schmid, Ingrid; Perfetto, Stephen P
2014-05-01
Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99-117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414-437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment. Published © 2014 Wiley Periodicals Inc.
Davis, William E; Li, Yongtao
2008-07-15
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.
Doyle, E; Fowles, S E; Summerfield, S; White, T J
2002-03-25
A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.
Soyuz 7 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2004-01-01
The toxicological assessments of one grab sample canister (GSC), 6 dual sorbent tubes (DSTs), and 20 formaldehyde badges returned aboard Soyuz 7 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSC were 84-89%. The recoveries of the less volatile surrogates from the DSTs were 87 to 112%; however, 13C-acetone was only recovered at 53-59%. Formaldehyde recoveries from 2 lab controls were 87 and 95%; trip controls were not returned to ground.
NASA Astrophysics Data System (ADS)
Doherty, W.; Lightfoot, P. C.; Ames, D. E.
2014-08-01
The effects of polynomial interpolation and internal standardization drift corrections on the inter-measurement dispersion (statistical) of isotope ratios measured with a multi-collector plasma mass spectrometer were investigated using the (analyte, internal standard) isotope systems of (Ni, Cu), (Cu, Ni), (Zn, Cu), (Zn, Ga), (Sm, Eu), (Hf, Re) and (Pb, Tl). The performance of five different correction factors was compared using a (statistical) range based merit function ωm which measures the accuracy and inter-measurement range of the instrument calibration. The frequency distribution of optimal correction factors over two hundred data sets uniformly favored three particular correction factors while the remaining two correction factors accounted for a small but still significant contribution to the reduction of the inter-measurement dispersion. Application of the merit function is demonstrated using the detection of Cu and Ni isotopic fractionation in laboratory and geologic-scale chemical reactor systems. Solvent extraction (diphenylthiocarbazone (Cu, Pb) and dimethylglyoxime (Ni) was used to either isotopically fractionate the metal during extraction using the method of competition or to isolate the Cu and Ni from the sample (sulfides and associated silicates). In the best case, differences in isotopic composition of ± 3 in the fifth significant figure could be routinely and reliably detected for Cu65/63 and Ni61/62. One of the internal standardization drift correction factors uses a least squares estimator to obtain a linear functional relationship between the measured analyte and internal standard isotope ratios. Graphical analysis demonstrates that the points on these graphs are defined by highly non-linear parametric curves and not two linearly correlated quantities which is the usual interpretation of these graphs. The success of this particular internal standardization correction factor was found in some cases to be due to a fortuitous, scale dependent, parametric curve effect.
Oyinlola, Lateefah A; Obadina, Adewale O; Omemu, Adebukunola M; Oyewole, Olusola B
2017-01-01
Lettuce is consumed raw in salads and is susceptible to microbial contamination through environment, agricultural practices, and its morphology, thus, a potential vehicle for food-borne illness. This study investigated the effect of adoption of food safety and hygienic practices by lettuce farmers on the microbial safety of field sourced lettuce in Lagos State, Nigeria. Ten structured questionnaires were administered randomly to 10 lettuce farmers to assess food safety and hygienic practices (FSH). Two farmers who practice FSH and two farmers who do not practice NFSH were finally used for this study. Samples of ready-to-harvest lettuce, manure applied, and irrigation water were obtained for a period of five months (August - December 2013) and analyzed for total plate count (TPC), total coliform count (TCC), Escherichia coli, Listeria spp., Salmonella spp., and Shigella spp . counts. Result of microbial analyses of lettuce samples was compared with international microbiological specification for ready-to-eat foods. Results showed that the range of TPC on lettuce was 6.00 to 8.11 LogCFU/g from FSH farms and TPC of lettuce samples from NFSH farms ranged from 6.66 to 13.64 LogCFU/g. 1.49 to 4.85LogCFU/g were TCC ranges from lettuce samples obtained from FSH farms while NFSH farms had TCC ranging between 3.95 and 10.86 LogCFU/g, respectively. The range of isolated pathogen count on lettuce from FSH and NFSH farms exceeded the international safety standard; there was a significant difference in the microbial count of lettuce from FSH farms and NFSH farms. This study concludes that the lettuce samples obtained did not pass the international microbial safety standards. FSH compliance is a major determinant of the microbial safety of lettuce. Hence, the institution of FSH on farm to improve microbial safety of lettuce produced for public consumption is emphasized.
Major inorganic elements in tap water samples in Peninsular Malaysia.
Azrina, A; Khoo, H E; Idris, M A; Amin, I; Razman, M R
2011-08-01
Quality drinking water should be free from harmful levels of impurities such as heavy metals and other inorganic elements. Samples of tap water collected from 24 locations in Peninsular Malaysia were determined for inorganic element content. Minerals and heavy metals were analysed by spectroscopy methods, while non-metal elements were analysed using test kits. Minerals and heavy metals determined were sodium, magnesium, potassium, calcium, chromium, manganese, iron, nickel, copper, zinc, arsenic, cadmium and lead while the non-metal elements were fluoride, chloride, nitrate and sulphate. Most of the inorganic elements found in the samples were below the maximum permitted levels recommended by inter-national drinking water standard limits, except for iron and manganese. Iron concentration of tap water from one of the locations was higher than the standard limit. In general, tap water from different parts of Peninsular Malaysia had low concentrations of heavy metals and inorganic elements.
Wang, Jian-Hua; Guo, Cui
2010-07-09
An analytical method for the determination of US EPA priority pollutant 16 polycyclic aromatic hydrocarbons (PAHs) in edible oil was developed by an isotope dilution gas chromatography-mass spectrometry (GC-MS). Extraction was performed with ultrasonication mode using acetonitrile as solvent, and subsequent clean-up was applied using narrow gel permeation chromatographic column. Three deuterated PAHs surrogate standards were used as internal standards for quantification and analytical quality control. The limits of quantification (LOQs) were globally below 0.5 ng/g, the recoveries were in the range of 81-96%, and the relative standard deviations (RSDs) were lower than 20%. Further trueness assessment of the method was also verified through participation in international cocoa butter proficiency test (T0638) organised by the FAPAS with excellent results in 2008. The results obtained with the described method were satisfying (z ≤ 2). The method has been applied to determine PAH in real edible oil samples.
A suggestion for royal jelly specifications.
Kanelis, Dimitrios; Tananaki, Chrysoula; Liolios, Vasilis; Dimou, Maria; Goras, Georgios; Rodopoulou, Maria Anna; Karazafiris, Emmanuel; Thrasyvoulou, Andreas
2015-12-01
This article proposes guidelines for quality standards of royal jelly. The proposals are based on two sets of data; the first from our study of the factors that may affect the royal jelly's chemical composition (protein and sugar supplementation of beehives) and the second on the analysis of a great number of samples from across Greece to establish natural variability of this product. We compared our findings with the adopted national limits, the proposals of the working group of the International Honey Commission (IHC), and the draft proposal of the International Organization of Standardization (ISO). The studied parameters included moisture, total proteins, sugars (fructose, glucose, sucrose, total sugars), and 10-hydroxy- 2-decenoic acid (10-HDA). Our results indicate that the limits for royal jelly in some countries should be amended and the proposals of the IHC and the ISO reviewed in view of recent data on variability. We believe that our proposals could be considered for setting global standards for royal jelly, as they incorporate national legislations, proposals of scientific groups, experimental data, and updated information.
Chang, Hui-Yin; Chen, Ching-Tai; Lih, T. Mamie; Lynn, Ke-Shiuan; Juo, Chiun-Gung; Hsu, Wen-Lian; Sung, Ting-Yi
2016-01-01
Efficient and accurate quantitation of metabolites from LC-MS data has become an important topic. Here we present an automated tool, called iMet-Q (intelligent Metabolomic Quantitation), for label-free metabolomics quantitation from high-throughput MS1 data. By performing peak detection and peak alignment, iMet-Q provides a summary of quantitation results and reports ion abundance at both replicate level and sample level. Furthermore, it gives the charge states and isotope ratios of detected metabolite peaks to facilitate metabolite identification. An in-house standard mixture and a public Arabidopsis metabolome data set were analyzed by iMet-Q. Three public quantitation tools, including XCMS, MetAlign, and MZmine 2, were used for performance comparison. From the mixture data set, seven standard metabolites were detected by the four quantitation tools, for which iMet-Q had a smaller quantitation error of 12% in both profile and centroid data sets. Our tool also correctly determined the charge states of seven standard metabolites. By searching the mass values for those standard metabolites against Human Metabolome Database, we obtained a total of 183 metabolite candidates. With the isotope ratios calculated by iMet-Q, 49% (89 out of 183) metabolite candidates were filtered out. From the public Arabidopsis data set reported with two internal standards and 167 elucidated metabolites, iMet-Q detected all of the peaks corresponding to the internal standards and 167 metabolites. Meanwhile, our tool had small abundance variation (≤0.19) when quantifying the two internal standards and had higher abundance correlation (≥0.92) when quantifying the 167 metabolites. iMet-Q provides user-friendly interfaces and is publicly available for download at http://ms.iis.sinica.edu.tw/comics/Software_iMet-Q.html. PMID:26784691
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-16
... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...
González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo
2016-09-01
A new method based on headspace programmed-temperature vaporizer gas chromatography with mass spectrometry has been developed and validated for the determination of amino acids (alanine, sarcosine, ethylglycine, valine, leucine, and proline) in human urine samples. Derivatization with ethyl chloroformate was employed successfully to determine the amino acids. The derivatization reaction conditions as well as the variables of the headspace sampling were optimized. The existence of a matrix effect was checked and the analytical characteristics of the method were determined. The limits of detection were 0.15-2.89 mg/L, and the limits of quantification were 0.46-8.67 mg/L. The instrumental repeatability was 1.6-11.5%. The quantification of the amino acids in six urine samples from healthy subjects was performed with the method developed with the one-point standard additions protocol, with norleucine as the internal standard. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Determination of uranium in tap water by ICP-MS.
El Himri, M; Pastor, A; de la Guardia, M
2000-05-01
A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%. Results obtained are comparable with those found by radiochemical methods for natural samples and of the same order for the certified content of a reference material, thus indicating the accuracy of the ICP-MS procedure without the need of using isotope dilution. A series of mineral and tap waters from different parts of Spain and Morocco were analysed.
Unceta, Nora; Gómez-Caballero, Alberto; García, Deiene; Díaz, Goretti; Guerreiro, Antonio; Piletsky, Sergey; Goicolea, M Aránzazu; Barrio, Ramón J
2013-11-15
This paper reports the application of a chiral imprinted polymer (CIP)-coated stir bar for the selective extraction of (+)-(S)-citalopram (SCIT) and its main metabolites, (+)-(S)-desmethylcitalopram (SDCIT) and (+)-(S)-didesmethylcitalopram (SDDCIT), from urine samples. The developed device has been demonstrated to be capable of selectively extracting the three target analytes from urine samples without saturating the imprinted sites. A CIP-coated stir bar sorptive extraction procedure (CIP-SBSE) is proposed for the isolation of SCIT, SDCIT and SDDCIT followed by their subsequent analysis using liquid chromatography ion trap mass spectrometry (LC-ITMS). Deuterated SCIT-d6 was used as an internal standard. The method was validated using a standard procedure, which revealed that a quantification of 5 ng mL(-1) was obtained in urine samples and that the accuracy and precision were within the established values while no matrix effect was observed. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Islam, Amina; Chevalier, Sylvie; Sassi, Mohamed
2018-04-01
With advances in imaging techniques and computational power, Digital Rock Physics (DRP) is becoming an increasingly popular tool to characterize reservoir samples and determine their internal structure and flow properties. In this work, we present the details for imaging, segmentation, as well as numerical simulation of single-phase flow through a standard homogenous Silurian dolomite core plug sample as well as a heterogeneous sample from a carbonate reservoir. We develop a procedure that integrates experimental results into the segmentation step to calibrate the porosity. We also look into using two different numerical tools for the simulation; namely Avizo Fire Xlab Hydro that solves the Stokes' equations via the finite volume method and Palabos that solves the same equations using the Lattice Boltzmann Method. Representative Elementary Volume (REV) and isotropy studies are conducted on the two samples and we show how DRP can be a useful tool to characterize rock properties that are time consuming and costly to obtain experimentally.
Manica, Scheila
2014-12-01
The INTERPOL (International Police Organization) Disaster Victim Identification forms represent a global standard for mass disasters and the collection of international ante-mortem dental records. These records can now be interpreted more easily with the help of a new online dictionary of dental terminology for translating dental charts from several languages into English. The free website launched in 2013 (www.internationaldentalcharts.org) is the result of a M.Sc project on international dental charts: Guide of International Dental Charts translated into English decoding international ante-mortem dental charts for INTERPOL's Ante-mortem (AM) Disaster Victim Identification (DVI) forms (Section F2), completed in 2011. The aim of this study was to analyze the tooth numbering system, symbols and abbreviations used on dental charting worldwide. A letter was sent to the national dental associations of the 188 INTERPOL member countries, addressing the goals of the project and asking for samples of dental charts. A total of 45 countries replied and 32 common dental alterations were selected for translation, such as: decay, filling and extraction. Their symbols and/or abbreviations used were summarized in various languages. More than one system of dental notations was used in the same country whereas there was an absence of standard systems in other countries. Some of the samples of charts received were of little value. However, a fair amount of useful information and detail was found in most of them. This free consultation website could be useful when the handwriting, symbols, and abbreviations on the ante-mortem dental charts are not clear. It will be particularly applicable when ante-mortem xrays and casts are not available.
Ullattuthodi, Sujana; Cherian, Kandathil Phillip; Anandkumar, R; Nambiar, M Sreedevi
2017-01-01
This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t -test and analysis of variance (ANOVA). The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings ( P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings ( P < 0.05). Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference.
Huynh, Dao; Zhou, Shao Jia; Gibson, Robert; Palmer, Lyndon; Muhlhausler, Beverly
2015-01-01
In this study a novel method to determine iodine concentrations in human breast milk was developed and validated. The iodine was analyzed by inductively coupled plasma mass spectrometry (ICPMS) following tetramethylammonium hydroxide (TMAH) extraction at 90°C in disposable polypropylene tubes. While similar approaches have been used previously, this method adopted a shorter extraction time (1h vs. 3h) and used antimony (Sb) as the internal standard, which exhibited greater stability in breast milk and milk powder matrices compared to tellurium (Te). Method validation included: defining iodine linearity up to 200μgL(-1); confirming recovery of iodine from NIST 1549 milk powder. A recovery of 94-98% was also achieved for the NIST 1549 milk powder and human breast milk samples spiked with sodium iodide and thyroxine (T4) solutions. The method quantitation limit (MQL) for human breast milk was 1.6μgL(-1). The intra-assay and inter-assay coefficient of variation for the breast milk samples and NIST powder were <1% and <3.5%, respectively. NIST 1549 milk powder, human breast milk samples and calibration standards spiked with the internal standard were all stable for at least 2.5 months after extraction. The results of the validation process confirmed that this newly developed method provides greater accuracy and precision in the assessment of iodine concentrations in human breast milk than previous methods and therefore offers a more reliable approach for assessing iodine concentrations in human breast milk. Copyright © 2014 Elsevier GmbH. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Lloyd A.
1996-10-17
The focus of this dissertation is the use of a twin quadrupole inductively coupled plasma mass spectrometer (ICP-MS) for the simultaneous detection of two m/z values. The twin quadrupole ICP-MS is used with laser ablation sample introduction in both the steady state (10 Hz) and single pulse modes. Steady state signals are highly correlated and the majority of flicker noise cancels when the ratio is calculated. Using a copper sample, the isotope ratio 63Cu +/ 65Cu + is measured with a relative standard deviation (RSD) of 0.26%. Transient signals for single laser pulses are also obtained. Copper isotope ratio measurementsmore » for several laser pulses are measured with an RSD of 0.85%. Laser ablation (LA) is used with steel samples to assess the ability of the twin quadrupole ICP-MS to eliminate flicker noise of minor components of steel samples. Isotopic and internal standard ratios are measured in the first part of this work. The isotope ratio 52Cr +/ 53Cr + (Cr present at 1.31 %) can be measured with an RSD of 0.06 % to 0.1 %. For internal standard elements, RSDs improve from 1.9 % in the Cr + signal to 0.12% for the ratio of 51V + to 52Cr +. In the second part of this work, one mass spectrometer is scanned while the second channel measures an individual m/z value. When the ratio of these two signals is calculated, the peak shapes in the mass spectrum are improved significantly. Pulses of analyte and matrix ions from individual drops are measured simultaneously using the twin quadrupole ICP-MS with monodisperse dried microparticulate injection (MDMI). At modest Pb concentrations (500 ppm), a shoulder on the leading edge of the Li + signal becomes apparent. Space charge effects are consistent with the disturbances seen.« less
Face consciousness among South Korean women: a culture-specific extension of objectification theory.
Kim, Si Yeon; Seo, Young Seok; Baek, Keun Young
2014-01-01
This study tested key tenets of objectification theory with South Korean women and explored the roles of sexually objectifying media and culture-specific standards of beauty in body image and eating disorder symptoms. Two pilot studies with South Korean college women (n = 40, n = 30) revealed that facial characteristics such as size and shape represent a discrete variable among culture-specific standards of beauty for South Korean women. Results with a sample of 562 South Korean college women indicated that media exposure had significant positive indirect relations with body shame and eating disorder symptoms through the mediating roles of internalization, body surveillance, and face surveillance. Internalization of cultural standards of beauty had significant positive direct relations with body surveillance and face surveillance and had both direct and indirect relations with body shame and eating disorder symptoms. Body and face surveillances had significant positive direct relations with body shame and had indirect relations with eating disorder symptoms. Finally, body shame mediated the links from internalization and surveillance variables to eating disorder symptoms. The results support the applicability of objectification theory as it relates to South Korean women and point to the significance of culture-specific standards of beauty within that framework. These findings could contribute to the broader field of multicultural body image research, with potential implications for therapist practices and training. (PsycINFO Database Record (c) 2014 APA, all rights reserved).
Lim, Hazel Sin Yue; Zheng, Qianwang; Miks-Krajnik, Marta; Turner, Matthew; Yuk, Hyun-Gyun
2015-06-01
The objective of this study was to evaluate performance of the commercial kit based on loop-mediated isothermal amplification (LAMP) in comparison with the International Organization for Standardization method for detecting uninjured and sublethally injured Salmonella cells artificially inoculated at levels of 10(0) and 10(1) CFU/25 g on raw duck wing, raw mung bean sprouts, and processed fishballs. Injured cells were prepared by a heat treatment for duck wings and fishball samples and a chlorine treatment for bean sprout samples. Additionally, a validation study was performed on naturally contaminated food samples sold in Singapore. A total of 110 samples of each commodity were analyzed in this study. Regardless of inoculum levels, the detection by the commercial LAMP kit showed 100% sensitivity and specificity for both inoculated and uninoculated samples compared with the International Organization for Standardization method, with the exception of bean sprout samples. Only 20% of bean sprout samples inoculated with 10(0) CFU/25 g injured Salmonella cells were positive by using the commercial LAMP-based kit. However, all negative samples became positive following a secondary enrichment in Rappaport-Vassiliadis medium with soy broth or after concentration by centrifugation. These results suggest that secondary enrichment or centrifugation should be considered as an additional step to increase the sensitivity of the commercial LAMP-based kit with low numbers of injured target cells in samples with high background microflora (such as mung bean sprouts). The validation study also showed that the commercial LAMP-based kit provided 91% sensitivity and 95% specificity for naturally contaminated samples. Thus, this study demonstrates that the commercial LAMP-based kit might be a cost-effective method, as this system could provide rapid, accurate detection of both uninjured and injured Salmonella cells on raw duck wings, raw mung bean sprouts, and processed fishballs in less than 26 h.
Adamec, Jiri; Yang, Wen-Chu; Regnier, Fred E
2014-01-14
Reagents and methods are provided that permit simultaneous analysis of multiple diverse small molecule analytes present in a complex mixture. Samples are labeled with chemically identical but isotopically distince forms of the labeling reagent, and analyzed using mass spectrometry. A single reagent simultaneously derivatizes multiple small molecule analytes having different reactive functional groups.
Citizen Observatories: A Standards Based Architecture
NASA Astrophysics Data System (ADS)
Simonis, Ingo
2015-04-01
A number of large-scale research projects are currently under way exploring the various components of citizen observatories, e.g. CITI-SENSE (http://www.citi-sense.eu), Citclops (http://citclops.eu), COBWEB (http://cobwebproject.eu), OMNISCIENTIS (http://www.omniscientis.eu), and WeSenseIt (http://www.wesenseit.eu). Common to all projects is the motivation to develop a platform enabling effective participation by citizens in environmental projects, while considering important aspects such as security, privacy, long-term storage and availability, accessibility of raw and processed data and its proper integration into catalogues and international exchange and collaboration systems such as GEOSS or INSPIRE. This paper describes the software architecture implemented for setting up crowdsourcing campaigns using standardized components, interfaces, security features, and distribution capabilities. It illustrates the Citizen Observatory Toolkit, a software suite that allows defining crowdsourcing campaigns, to invite registered and unregistered participants to participate in crowdsourcing campaigns, and to analyze, process, and visualize raw and quality enhanced crowd sourcing data and derived products. The Citizen Observatory Toolkit is not a single software product. Instead, it is a framework of components that are built using internationally adopted standards wherever possible (e.g. OGC standards from Sensor Web Enablement, GeoPackage, and Web Mapping and Processing Services, as well as security and metadata/cataloguing standards), defines profiles of those standards where necessary (e.g. SWE O&M profile, SensorML profile), and implements design decisions based on the motivation to maximize interoperability and reusability of all components. The toolkit contains tools to set up, manage and maintain crowdsourcing campaigns, allows building on-demand apps optimized for the specific sampling focus, supports offline and online sampling modes using modern cell phones with built-in sensing technologies, automates the upload of the raw data, and handles conflation services to match quality requirements and analysis challenges. The strict implementation of all components using internationally adopted standards ensures maximal interoperability and reusability of all components. The Citizen Observatory Toolkit is currently developed as part of the COBWEB research project. COBWEB is partially funded by the European Programme FP7/2007-2013 under grant agreement n° 308513; part of the topic ENV.2012.6.5-1 "Developing community based environmental monitoring and information systems using innovative and novel earth observation applications.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Rossi, Patrizia; Pozio, Edoardo
2008-01-01
The European Community Regulation (EC) No. 2075/2005 lays down specific rules on official controls for the detection of Trichinella in fresh meat for human consumption, recommending the pooled-sample digestion method as the reference method. The aim of this document is to provide specific guidance to implement an appropriate Trichinella digestion method by a laboratory accredited according to the ISO/IEC 17025:2005 international standard, and performing microbiological testing following the EA-04/10:2002 international guideline. Technical requirements for the correct implementation of the method, such as the personnel competence, specific equipments and reagents, validation of the method, reference materials, sampling, quality assurance of results and quality control of performance are provided, pointing out the critical control points for the correct implementation of the digestion method.
Nestola, Marco; Thellmann, Andrea
2015-01-01
An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.
Tang, Hongmao; Beg, Khaliq R.; Al-Otaiba, Yousef
2006-01-01
Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results. PMID:16699723
Tang, Hongmao; Beg, Khaliq R; Al-Otaiba, Yousef
2006-05-12
Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.
Validity and cultural equivalence of the standard Greene Climacteric Scale in Hong Kong.
Chen, Run Qiu; Davis, Susan R; Wong, Chit Ming; Lam, Tai Hing
2010-01-01
The aim of this study was to translate the standard Greene Climacteric Scale (GCS) and a urogenital symptom scale into colloquial Chinese (Hong Kong) and test their validity and reliability in Hong Kong Chinese women. The scales were translated with standard techniques, and cross-cultural construct validity, internal consistency, test-retest reliability, and responsiveness were tested on samples of women aged 40 to 60 years recruited from the community. A total of 611 women, with mean (SD) age of 48.9 (5.3) years, provided completed scales for the study. Confirmatory factor analysis demonstrated construct validity of the translated standard GCS. The items were found to have good homogeneity in measuring the scale concepts (Cronbach alpha > 0.7). But the three-item urogenital scale had poor internal consistency (Cronbach alpha = 0.43), and a combination of this scale with the standard GCS resulted in a reduced model fit to the data. Test-retest reliability for the GCS was good on women recruited for a retest (n = 52). The translated GCS was found to be responsive to change over time (effect size, 0.59; n = 19). The Chinese (Hong Kong) version of the standard GCS is a valid and cultural-equivalent instrument. Our data do not support inclusion of the urogenital scale to the standard GCS. Measurement of urogenital symptoms is subject to further study.
Bridoux, Maxime C; Malandain, Hélène; Leprince, Françoise; Progent, Frédéric; Machuron-Mandard, Xavier
2015-04-15
A novel hyphenated technique, namely the combination of stir bar sorptive extraction (SBSE) with isotope dilution direct analysis in real time (DART) Orbitrap™ mass spectrometry (OT-MS) is presented for the extraction of phosphoric acid alkyl esters (tri- (TnBP), di- (HDBP), and mono-butyl phosphate (H2MBP)) from aqueous samples. First, SBSE of phosphate esters was performed using a Twister™ coated with 24 μL of polydimethylsiloxane (PDMS) as the extracting phase. SBSE was optimized for extraction pH, phase ratio (PDMS volume/aqueous phase volume), stirring speed, extraction time and temperature. Then, coupling of SBSE to DART/Orbitrap-MS was achieved by placing the Twister™ in the middle of an open-ended glass tube between the DART and the Orbitrap™. The DART mass spectrometric response of phosphate esters was probed using commercially available and synthesized alkyl phosphate ester standards. The positive ion full scan spectra of alkyl phosphate triesters (TnBP) was characterized by the product of self-protonation [M+H](+) and, during collision-induced dissociation (CID), the major fragmentation ions corresponded to consecutive loss of alkyl chains. Negative ionization gave abundant [M-H](-) ions for both HDnBP and H2MnBP. Twisters™ coated with PDMS successfully extracted phosphate acid esters (tri-, di- and mono-esters) granted that the analytes are present in the aqueous solution in the neutral form. SBSE/DART/Orbitrap-MS results show a good linearity between the concentrations and relative peak areas for the analytes in the concentration range studied (0.1-750 ng mL(-1)). Reproducibility of this SBSE/DART/Orbitrap-MS method was evaluated in terms of %RSD by extracting a sample of water fortified with the analytes. The %RSDs for TnBP, HDnBP and H2MnBP were 4, 3 and 3% (n=5) using the respective perdeuterated internal standards. Matrix effects were investigated by matrix matched calibration standards using underground water samples (UWS) and river water samples (RWS). Matrix effects were effectively compensated by the addition of the perdeuterated internal standards. The application of this new SBSE/DART/Orbitrap-MS method should be very valuable for on-site sampling/monitoring, limiting the transport of large volumes of water samples from the sampling site to the laboratory. Copyright © 2015 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-21
... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY: Environmental Protection... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance...
78 FR 63873 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... Internal Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class... Internal Control Standards. 64 FR 590. The rule added a new part to the Commission's regulations...
78 FR 11793 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-20
... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... NIGC published a final rule in the Federal Register called Minimum Internal Control Standards. 64 FR...
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
NASA Astrophysics Data System (ADS)
Moro, Giovanni; Zannoni, Daniele; Dreossi, Giuliano; Stenni, Barbara
2017-04-01
The objective of this work is the development, standardization and creation of a method to carry out continuous measurement of oxygen and hydrogen isotopic composition of the atmospheric water vapor using a wavelength-scanned cavity ring down spectroscopy (WS-CRDS) instrument produced by Picarro, L1102-i model. Some technical improvements of the standard instrument configuration have been made to create three different inlet gas lines: a "standard" line, a calibration line and a line connected with the external sampler. The calibration line is composed of a syringe-pump that continuously injects standard water into a steel tee heated at the temperature of 170°C and flushed with dry nitrogen gas. In this way, instantaneous and complete vaporization of the standard water takes place. The resulting steam is characterized by a well-defined composition in δD e δ18O values. To allow comparison with other international data, we have characterized the individual instrumental response to variation of the isotopic composition of the water vapor. Several humidity-isotope response functions (6000-26000 ppmv) have been estimated with three different internal standards (0.35‰ -8.75‰ -29.11‰ and -40.28‰ for δ18O; 2.31‰ -58.91‰ -222.19‰ and -317.78‰ for δD). Moreover, we have measured the instrumental drift at regular time intervals to apply the opportune corrections to instrument data. The setup has been tested using a 3.5 day continuous measurements carried out with the Picarro sampling the water vapor outside our campus in Venice and parallel sampling using the classical cryogenic trapping procedure, obtaining excellent results. Furthermore, our analysis technique has given good results for the standards with values which are similar to those obtained with the isotope ratio mass spectrometry (IRMS) technique.
Cífková, Eva; Holčapek, Michal; Lísa, Miroslav; Ovčačíková, Magdaléna; Lyčka, Antonín; Lynen, Frédéric; Sandra, Pat
2012-11-20
The identification and quantitation of a wide range of lipids in complex biological samples is an essential requirement for the lipidomic studies. High-performance liquid chromatography-mass spectrometry (HPLC/MS) has the highest potential to obtain detailed information on the whole lipidome, but the reliable quantitation of multiple lipid classes is still a challenging task. In this work, we describe a new method for the nontargeted quantitation of polar lipid classes separated by hydrophilic interaction liquid chromatography (HILIC) followed by positive-ion electrospray ionization mass spectrometry (ESI-MS) using a single internal lipid standard to which all class specific response factors (RFs) are related to. The developed method enables the nontargeted quantitation of lipid classes and molecules inside these classes in contrast to the conventional targeted quantitation, which is based on predefined selected reaction monitoring (SRM) transitions for selected lipids only. In the nontargeted quantitation method described here, concentrations of lipid classes are obtained by the peak integration in HILIC chromatograms multiplied by their RFs related to the single internal standard (i.e., sphingosyl PE, d17:1/12:0) used as common reference for all polar lipid classes. The accuracy, reproducibility and robustness of the method have been checked by various means: (1) the comparison with conventional lipidomic quantitation using SRM scans on a triple quadrupole (QqQ) mass analyzer, (2) (31)P nuclear magnetic resonance (NMR) quantitation of the total lipid extract, (3) method robustness test using subsequent measurements by three different persons, (4) method transfer to different HPLC/MS systems using different chromatographic conditions, and (5) comparison with previously published results for identical samples, especially human reference plasma from the National Institute of Standards and Technology (NIST human plasma). Results on human plasma, egg yolk and porcine liver extracts are presented and discussed.
Zhang, Lin; Small, Gary W; Arnold, Mark A
2003-11-01
The transfer of multivariate calibration models is investigated between a primary (A) and two secondary Fourier transform near-infrared (near-IR) spectrometers (B, C). The application studied in this work is the use of bands in the near-IR combination region of 5000-4000 cm(-)(1) to determine physiological levels of glucose in a buffered aqueous matrix containing varying levels of alanine, ascorbate, lactate, triacetin, and urea. The three spectrometers are used to measure 80 samples produced through a randomized experimental design that minimizes correlations between the component concentrations and between the concentrations of glucose and water. Direct standardization (DS), piecewise direct standardization (PDS), and guided model reoptimization (GMR) are evaluated for use in transferring partial least-squares calibration models developed with the spectra of 64 samples from the primary instrument to the prediction of glucose concentrations in 16 prediction samples measured with each secondary spectrometer. The three algorithms are evaluated as a function of the number of standardization samples used in transferring the calibration models. Performance criteria for judging the success of the calibration transfer are established as the standard error of prediction (SEP) for internal calibration models built with the spectra of the 64 calibration samples collected with each secondary spectrometer. These SEP values are 1.51 and 1.14 mM for spectrometers B and C, respectively. When calibration standardization is applied, the GMR algorithm is observed to outperform DS and PDS. With spectrometer C, the calibration transfer is highly successful, producing an SEP value of 1.07 mM. However, an SEP of 2.96 mM indicates unsuccessful calibration standardization with spectrometer B. This failure is attributed to differences in the variance structure of the spectra collected with spectrometers A and B. Diagnostic procedures are presented for use with the GMR algorithm that forecasts the successful calibration transfer with spectrometer C and the unsatisfactory results with spectrometer B.
Cvan Trobec, Katja; Trontelj, Jurij; Springer, Jochen; Lainscak, Mitja; Kerec Kos, Mojca
2014-05-01
Dried blood spot (DBS) sampling represents a suitable method for pharmacokinetic studies in rats, particularly if serial sampling is needed. To study the pharmacokinetics of drugs in a rat heart failure (HF) model, we developed and validated a method for the simultaneous determination of bisoprolol, ramiprilat, propranolol and midazolam in DBS samples. Bisoprolol and ramipril are widely used in the treatment of HF, and midazolam and propranolol are markers of hepatic metabolism, which can be altered in HF. A 20μL sample of rat blood was pipetted onto Whatman 903 Protein Saver Card and allowed to dry. The whole spot was excised and 300μL of solvent (methanol with 10% ultrapure water and 0.1% formic acid) was added. After mixing and incubating the sample in an ultrasonic bath, a mixture of isotopically labeled internal standards was added. After centrifugation, the extracts were cleaned on an Ostro™ plate and analyzed using liquid chromatography-tandem mass spectroscopy. The method was successfully validated. No significant interference was observed in the retention times of analytes or internal standards. The intraday and interday accuracy and precision were within a ±15% interval. The method was linear in the range 5-250μg/L and the lower limit of quantification was 5μg/L for all four analytes. The absolute matrix effect ranged from 98.7% for midazolam to 121% for ramiprilat. The recovery was lowest for ramiprilat and highest for propranolol. Samples were stable at all tested temperatures. The method has been used successfully in a real-time pharmacokinetic study in rats. Copyright © 2014 Elsevier B.V. All rights reserved.
Tremblay, Patrice; Paquin, Réal
2007-01-24
Stable carbon isotope ratio mass spectrometry (delta13C IRMS) was used to detect maple syrup adulteration by exogenous sugar addition (beet and cane sugar). Malic acid present in maple syrup is proposed as an isotopic internal standard to improve actual adulteration detection levels. A lead precipitation method has been modified to isolate quantitatively malic acid from maple syrup using preparative reversed-phase liquid chromatography. The stable carbon isotopic ratio of malic acid isolated from this procedure shows an excellent accuracy and repeatability of 0.01 and 0.1 per thousand respectively, confirming that the modified lead precipitation method is an isotopic fractionation-free process. A new approach is proposed to detect adulteration based on the correlation existing between the delta13Cmalic acid and the delta13Csugars-delta13Cmalic acid (r = 0.704). This technique has been tested on a set of 56 authentic maple syrup samples. Additionally, authentic samples were spiked with exogeneous sugars. The mean theoretical detection level was statistically lowered using this technique in comparison with the usual two-standard deviation approach, especially when maple syrup is adulterated with beet sugar : 24 +/- 12% of adulteration detection versus 48 +/- 20% (t-test, p = 7.3 x 10-15). The method was also applied to published data for pineapple juices and honey with the same improvement.
Qiu, Zhongli; Lin, Ying; Xiong, Zhili; Xie, Jianwei
2014-07-01
A method for the determination of endogenous agmatine in rat plasma was developed by isotope dilution-gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS). The plasma samples were analyzed after protein precipitation, evaporation, derivatization by hexafluoroacetone (HFAA), and clean-up on a Florisil SPE column. The GC-MS analysis utilized stable isotope d8-agmatine as internal standard. The samples after treatme were tested by negative chemical ionization with selected ion monitoring (SIM) which was set at m/z 492 (molecular ion of agmatine) and m/z 500 (molecular ion of internal standard). The limit of detection (LOD) of agmatine standard solution was 0.005 7 ng/mL. The calibration curve of the agmatine spiked in rat plasma showed a good linear relationship at the range of 1.14-57.0 ng/mL (r = 0.997). The recoveries of agmatine spiked in rat plasma ranged from 92.3% to 109.8%. Inter-day and intra-day precisions were less than 15%. The average concentration level of agmatine in rat plasma was (22 +/- 9) ng/mL, and there was no significant difference between male and female SD rats (p > 0.05). The method is high sensitive and specific, and can be used for the determination of endogenous agmatine in plasma. It provides a strong support for the subsequent research of agmatine.
L'Empereur, Karen; Stadalius, Marilyn; Zhu, Yongdong; Mansoori, Bashir A; Isemura, Tsuguhide; Kaiser, Mary A; Knaup, Wolfgang; Noguchi, Masahiro
2008-08-01
Fluorotelomer-based acrylic polymers are applied to the surface of carpet to impart oil, stain, and water repellence properties. Concerns that fluorotelomer-based polymers are a possible source of "low level" exposure to humans, coupled with their widespread use have prompted the need to develop a method to detect and measure perfluorooctanoate (PFO) in carpet. A liquid chromatography tandem mass spectrometry method for the determination of PFO in carpet using a dual labeled 13C-perfluoroctanoic acid (13C-PFOA) internal standard is successfully developed and validated. Levels of PFO are determined using a gradient, reversed-phase high-performance liquid chromatography (HPLC) method with acetic acid acidified water-methanol, separated on a 50 mm Phenomenex Synergi Polar RP column. Ions monitored are 413 (parent) and 369 (daughter) for PFO and 415 (parent) and 370 (daughter) for dual labeled 13C-PFOA internal standard. Accuracy and precision over three days for 5 to 900 ng/g PFO in carpet ranged from 2.4% to 7.6% and 3.7% to 14.1%, respectively. Overall extraction efficiency for samples (n=30) fortified with 13C-PFOA at 20 ng/g and perfluorooctanoic acid (PFOA) at 5, 50, and 500 ng/g is 98.9%+/-8.1%. Specificity of the method was evaluated with two different carpet samples.
77 FR 32444 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... the Federal Register called Minimum Internal Control Standards. 64 FR 590. The rule added a new part...
Xu, Fei; Liu, Feng; Wang, Chaozhan; Wei, Yinmao
2018-02-01
In this study, the strategy of unique adsorbent combined with isotope labeled internal standards was used to significantly reduce the matrix effect for the enrichment and analysis of nine fluoroquinolones in a complex sample by liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (LC-QqQ LIT -MS/MS). The adsorbent was prepared conveniently by functionalizing Fe 3 O 4 @SiO 2 microspheres with phenyl and tetrazolyl groups, which could adsorb fluoroquinolones selectively via hydrophobic, electrostatic, and π-π interactions. The established magnetic solid-phase extraction (MSPE) method as well as using stable isotope labeled internal standards in the next MS/MS detection was able to reduce the matrix effect significantly. In the process of LC-QqQ LIT -MS/MS analysis, the precursor and product ions of the analytes were monitored quantitatively and qualitatively on a QTrap system equipped simultaneously with the multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan. Subsequently, the enrichment method combined with LC-QqQ LIT -MS/MS demonstrated good analytical features in terms of linearity (7.5-100.0 ng mL -1 , r > 0.9960), satisfactory recoveries (88.6%-118.3%) with RSDs < 12.0%, LODs = 0.5 μg kg -1 and LOQs = 1.5 μg kg -1 for all tested analytes. Finally, the developed MSPE-LC-QqQ LIT -MS/MS method had been successfully applied to real pork samples for food-safety risk monitoring in Ningxia Province, China. Graphical abstract Mechanism of reducing matrix effect through the as-prepared adsorbent.
Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays
Bouthry, Elise; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane
2016-01-01
Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. PMID:27147722
Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays.
Bouthry, Elise; Furione, Milena; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane; Vauloup-Fellous, Christelle
2016-07-01
Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Hoad, Kirsten E; Johnson, Lambro A; Woollard, Gerald A; Walmsley, Trevor A; Briscoe, Scott; Jolly, Lisa M; Gill, Janice P; Greaves, Ronda F
2013-06-01
The RCPA Quality Assurance Program (RCPA QAP) offers monthly proficiency testing for vitamins A, B1, B6, β-carotene, C and E to laboratories worldwide. A review of the results submitted for the whole blood vitamin B1/B6 sub-program revealed a wide dispersion. Here we describe the results of a methodology survey for vitamins B1 and B6. A questionnaire was sent to thirteen laboratories. Eleven laboratories were returning QAP results for vitamin B1 (thiamine diphosphate) and five were returning results for vitamin B6 (pyridoxal-5-phosphate). All nine respondents provided a clinical service for vitamins B1 and B6. HPLC with fluorescence detection was the most common method principle. For vitamin B1, six respondents used a commercial assay whilst three used in-house methods; whole blood was the matrix for all. For vitamin B6, five respondents used commercial assays and four used in-house assays. The choice of matrix for vitamin B6 varied with three respondents using whole blood and five using plasma for analysis. Sample preparation incorporated protein precipitation and derivatization steps. An internal standard was employed in sample preparation by only one survey respondent. The immediate result of this survey was the incorporation of plasma vitamin B6 into the RCPA QAP vitamin program. The absence of an internal standard in current vitamin B1 and B6 assays is a likely contributor to the wide dispersion of results seen in this program. We recommend kit manufacturers and laboratories investigate the inclusion of internal standards to correct the variability that may occur during processing. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Joyce, Barbara L; Steenbergh, Timothy; Scher, Eric
2010-06-01
This study examined the psychometric properties of the Kalamazoo Essential Elements Communication Checklist (Adapted) (KEECC-A), which addresses 7 key elements of physician communication identified in the Kalamazoo Consensus Statement, in a sample of 135 residents in multiple specialties at a large urban medical center in 2008-2009. The KEECC-A was used by residents, standardized patients, and faculty as the assessment tool in a broader institutional curriculum initiative. Three separate KEECC-A scores (self-ratings, faculty ratings, and standardized patient ratings) were calculated for each resident to assess the internal consistency and factor structure of the checklist. In addition, we analyzed KEECC-A ratings by gender and US versus international medical graduates, and collected American Board of Internal Medicine Patient Satisfaction Questionnaire (PSQ) scores for a subsample of internal medicine residents (n = 28) to examine the relationship between this measure and the KEECC-A ratings to provide evidence of convergent validity. The KEECC-A ratings generated by faculty, standardized patients, and the residents themselves demonstrated a high degree of internal consistency. Factor analyses of the 3 different sets of KEECC-A ratings produced a consistent single-factor structure. We could not examine the relationship between KEECC-A and the PSQ because of substantial range restriction in PSQ scores. No differences were seen in the communication scores of men versus women. Faculty rated US graduates significantly higher than international medical graduates. Our study provides evidence for the reliability and validity of the KEECC-A as a measure of physician communication skills. The KEECC-A appears to be a psychometrically sound, user-friendly communication tool, linked to an expert consensus statement, that can be quickly and accurately completed by multiple raters across diverse specialties.
Internal Hydrolysis Indicator for Sample Specific Monitoring of β-Glucuronidase Activity.
Taylor, Lacy L; Flint, Noah A; Ma, Vinh; Hill, Brandy M; Clark, Chantry J; Strathmann, Frederick G
2017-06-01
Metabolized forms of benzodiazepines (benzos) can cause issues with mass spectrometry identification. Benzodiazepines undergo a process called glucuronidation during metabolism that attaches a glucuronic acid for increased solubility. Often in clinical testing an enzymatic hydrolysis step is implemented to increase the sensitivity of benzodiazepines by hydrolyzing β-D-glucuronic acid from benzodiazepine-glucuronide conjugates in urine samples using the β-Glucuronidase enzyme. In this study resorufin β-D-glucuronide, a substrate of the β-Glucuronidase enzyme, was added to patient samples to determine if proper hydrolysis had occurred. The presence of resorufin as an Internal Hydrolysis Indicator (IHI) shows the activity and efficiency of the enzyme in each patient sample. Synthetic/patient urine samples were obtained and mixed with hydrolysis buffer containing resorufin β-D-glucuronide. The β-Glucuronidase enzyme was used to hydrolyze the benzodiazepine analytes as well as resorufin β-D-glucuronide. The enzymatic hydrolysis addition increased the positivity rate of benzodiazepines by 42.5%. The β-Glucuronidase substrate resorufin (IHI) displayed variability in area counts between patient samples. Comparative studies with internal standards and resorufin (IHI) showed no correlation between recovery and analyte variability. Hydrolysis reactions greatly improved the sensitivity of benzodiazepines by liquid chromatography time-of-flight mass spectrometry analysis. The large variation in resorufin (IHI) area counts amongst patient samples indicates possible variability in enzymatic hydrolysis activity. The enzymatic hydrolysis step is a part of the extraction procedure and should be controlled for in each patient sample. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornwell, R.J.; Knutti, E.; Lyman, M.
1990-11-01
In response to a request from the International Brotherhood of Teamsters, Chauffeurs, Warehousemen, and Helpers of America, a study was conducted of possible hazardous working conditions at MAP International (SIC-3296), Fairmont, West Virginia. The facility manufactured fibrous-glass for thermal and acoustical insulation. Personal breathing zone samples and area air samples were taken and analyzed for exposure to fibrous-glass (14808607), formaldehyde (50000), phenol (108952), ammonia (7664417), and organic vapors. The levels detected were all below allowable standards. Workers were not following recommended safety and health procedures prescribed in the Material Safety Data Sheets for the materials they were using. The medicalmore » questionnaires indicated workers were experiencing symptoms consistent with exposure to fibrous-glass and the materials used in its production. Eye irritation, upper respiratory irritation, skin irritation, chronic cough, and shortness of breath were demonstrated. The author recommends specific measures to reduce exposures and improve work practices.« less
[The practical measurement of health literacy in Hungary and in international comparison].
Koltai, Júlia; Kun, Eszter
2016-12-01
The study presents results of an innovative measurement of practical health literacy in international context. To show the level of practical health literacy in the Hungarian society and in international comparison. We measured practical health literacy with Newest Vital Sign test on a Hungarian national representative sample, asked from 1008 persons, between May and June, 2015 from population 16 years or older, using methodological standards of Eurobarometer. The sample is representative to the above mentioned population by gender, age, region and settlement-size. Based on Newest Vital Sign test, members of the Hungarian society have good practical health literacy. The accomplishment is inconsistent with self-reported health literacy, since it shows weak results. As low level of self-reported health literacy implies that respondents don't have daily routine in practicing their skills, we could draw people's attention to food-information, that are important and show, how to utilize them. Orv. Hetil., 2016, 157(50), 2002-2006.
Development of an Atmospheric Pressure Ionization Mass Spectrometer
NASA Technical Reports Server (NTRS)
1998-01-01
A commercial atmospheric pressure ionization mass spectrometer (APIMS) was purchased from EXTREL Mass Spectrometry, Inc. (Pittsburgh, PA). Our research objectives were to adapt this instrument and develop techniques for real-time determinations of the concentrations of trace species in the atmosphere. The prototype instrument is capable of making high frequency measurements with no sample preconcentrations. Isotopically labeled standards are used as an internal standard to obtain high precision and to compensate for changes in instrument sensitivity and analyte losses in the sampling manifold as described by Bandy and coworkers. The prototype instrument is capable of being deployed on NASA C130, Electra, P3, and DC8 aircraft. After purchasing and taking delivery by June 1994, we assembled the mass spectrometer, data acquisition, and manifold flow control instrumentation in electronic racks and performed tests.
Determination of thorium by fluorescent x-ray spectrometry
Adler, I.; Axelrod, J.M.
1955-01-01
A fluorescent x-ray spectrographic method for the determination of thoria in rock samples uses thallium as an internal standard. Measurements are made with a two-channel spectrometer equipped with quartz (d = 1.817 A.) analyzing crystals. Particle-size effects are minimized by grinding the sample components with a mixture of silicon carbide and aluminum and then briquetting. Analyses of 17 samples showed that for the 16 samples containing over 0.7% thoria the average error, based on chemical results, is 4.7% and the maximum error, 9.5%. Because of limitations of instrumentation, 0.2% thoria is considered the lower limit of detection. An analysis can be made in about an hour.
Conway, Thomas [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA); Tans, Pieter [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA)
2009-01-01
The National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) has measured CO2 in air samples collected weekly at a global network of sites since the late 1960s. Atmospheric CO2 mixing ratios reported in these files were measured by a nondispersive infrared absorption technique in air samples collected in glass flasks. All CMDL flask samples are measured relative to standards traceable to the World Meteorological Organization (WMO) CO2 mole fraction scale. These measurements constitute the most geographically extensive, carefully calibrated, internally consistent atmospheric CO2 data set available and are essential for studies aimed at better understanding the global carbon cycle budget.
Standardized protocols for quality control of MRM-based plasma proteomic workflows.
Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H
2013-01-04
Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.
Haack, Robert A.; Britton, Kerry O.; Brockerhoff, Eckehard G.; Cavey, Joseph F.; Garrett, Lynn J.; Kimberley, Mark; Lowenstein, Frank; Nuding, Amelia; Olson, Lars J.; Turner, James; Vasilaky, Kathryn N.
2014-01-01
Numerous bark- and wood-infesting insects have been introduced to new countries by international trade where some have caused severe environmental and economic damage. Wood packaging material (WPM), such as pallets, is one of the high risk pathways for the introduction of wood pests. International recognition of this risk resulted in adoption of International Standards for Phytosanitary Measures No. 15 (ISPM15) in 2002, which provides treatment standards for WPM used in international trade. ISPM15 was originally developed by members of the International Plant Protection Convention to “practically eliminate” the risk of international transport of most bark and wood pests via WPM. The United States (US) implemented ISPM15 in three phases during 2005–2006. We compared pest interception rates of WPM inspected at US ports before and after US implementation of ISPM15 using the US Department of Agriculture AQIM (Agriculture Quarantine Inspection Monitoring) database. Analyses of records from 2003–2009 indicated that WPM infestation rates declined 36–52% following ISPM15 implementation, with results varying in statistical significance depending on the selected starting parameters. Power analyses of the AQIM data indicated there was at least a 95% chance of detecting a statistically significant reduction in infestation rates if they dropped by 90% post-ISPM15, but the probability fell as the impact of ISPM15 lessened. We discuss several factors that could have reduced the apparent impact of ISPM15 on lowering WPM infestation levels, and suggest ways that ISPM15 could be improved. The paucity of international interception data impeded our ability to conduct more thorough analyses of the impact of ISPM15, and demonstrates the need for well-planned sampling programs before and after implementation of major phytosanitary policies so that their effectiveness can be assessed. We also present summary data for bark- and wood-boring insects intercepted on WPM at US ports during 1984–2008. PMID:24827724
NASA Astrophysics Data System (ADS)
Howe, Michael
2014-05-01
Much of the digital geological information on the composition, properties and dynamics of the subsurface is based ultimately on physical samples, many of which are archived to provide a basis for the information. Online metadata catalogues of these collections have now been available for many years. Many of these are institutional and tightly focussed, with UK examples including the British Geological Survey's (BGS) palaeontological samples database, PalaeoSaurus (http://www.bgs.ac.uk/palaeosaurus/), and mineralogical and petrological sample database, Britrocks (http://www.bgs.ac.uk/data/britrocks.html) . There are now a growing number of international sample metadata databases, including The Palaeobiology Database (http://paleobiodb.org/) and SESAR, the IGSN (International Geo Sample Number) database (http://www.geosamples.org/catalogsearch/ ). More recently the emphasis has moved beyond metadata (locality, identification, age, citations, etc) to digital imagery, with the intention of providing the user with at least enough information to determine whether viewing the sample would be worthwhile. Recent BGS examples include high resolution (e.g. 7216 x 5412 pixel) hydrocarbon well core images (http://www.bgs.ac.uk/data/offshoreWells/wells.cfc?method=searchWells) , high resolution rock thin section images (e.g. http://www.largeimages.bgs.ac.uk/iip/britrocks.html?id=290000/291739 ) and building stone images (http://geoscenic.bgs.ac.uk/asset-bank/action/browseItems?categoryId=1547&categoryTypeId=1) . This has been developed further with high resolution stereo images. The Jisc funded GB3D type fossils online project delivers these as red-cyan anaglyphs (http://www.3d-fossils.ac.uk/). More innovatively, the GB3D type fossils project has laser scanned several thousand type fossils and the resulting 3d-digital models are now being delivered through the online portal. Importantly, this project also represents collaboration between the BGS, Oxford and Cambridge Universities, the National Museums of Wales, and numerous other national, local and regional museums. The lack of currently accepted international standards and infrastructures for the delivery of high resolution images and 3d-digital models has necessitated the BGS in developing or selecting its own. Most high resolution images have been delivered using the JPEG 2000 format because of its quality and speed. Digital models have been made available in both .PLY and .OBJ format because of their respective efficient file size, and flexibility. Consideration must now be given to European and international standards and infrastructures for the delivery of high resolution images and 3d-digital models.
Wassenaar, L I; Terzer-Wassmuth, S; Douence, C; Araguas-Araguas, L; Aggarwal, P K; Coplen, T B
2018-03-15
Water stable isotope ratios (δ 2 H and δ 18 O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test. Eight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies. For the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ 18 O and δ 2 H, respectively; ~27 % produced unacceptable results. Top performance for δ 18 O values was dominated by dual-inlet IRMS laboratories; top performance for δ 2 H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected. Analysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1-2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples. Copyright © 2018 John Wiley & Sons, Ltd.
Wassenaar, L. I.; Terzer-Wassmuth, S.; Douence, C.; Araguas-Araguas, L.; Aggarwal, P. K.; Coplen, Tyler B.
2018-01-01
RationaleWater stable isotope ratios (δ2H and δ18O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test.MethodsEight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies.ResultsFor the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ18O and δ2H, respectively; ~27 % produced unacceptable results. Top performance for δ18O values was dominated by dual-inlet IRMS laboratories; top performance for δ2H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected.ConclusionsAnalysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1–2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples.
Planetary protection - assaying new methods
NASA Astrophysics Data System (ADS)
Nellen, J.; Rettberg, P.; Horneck, G.
Space age began in 1957 when the USSR launched the first satellite into earth orbit. In response to this new challenge the International Council for Science, formerly know as International Council of Scientific Unions (ICSU), established the Committee on Space Research (COSPAR) in 1958. The role of COSPAR was to channel the international scientific research in space and establish an international forum. Through COSPAR the scientific community agreed on the need for screening interplanetary probes for forward (contamination of foreign planets) and backward (contamination of earth by returned samples/probes) contamination. To prevent both forms of contamination a set of rules, as a guideline was established. Nowadays the standard implementation of the planetary protection rules is based on the experience gained during NASA's Viking project in 1975/76. Since then the evaluation-methods for microbial contamination of spacecrafts have been changed or updated just slowly. In this study the standard method of sample taking will be evaluated. New methods for examination of those samples, based on the identification of life on the molecular level, will be reviewed and checked for their feasibility as microbial detection systems. The methods will be examined for their qualitative (detection and verification of different organisms) and quantitative (detection limit and concentration verification) qualities. Amongst the methods analyzed will be i.e. real-time / PCR (poly-chain-reaction), using specific primer-sets for the amplification of highly conserved rRNA or DNA regions. Measurement of intrinsic fluorescence, i.e ATP using luciferin-luciferase reagents. The use of FAME (fatty acid methyl esters) and microchips for microbial identification purposes. The methods will be chosen to give a good overall coverage of different possible molecular markers and approaches. The most promising methods shall then be lab-tested and evaluated for their use under spacecraft assembly conditions. Since mars became one of the most sought-after planets in our solar system and will be visited by man-made probes quiet often in the near future, planetary protection is as important as never before.
Jack, Clifford R; Barkhof, Frederik; Bernstein, Matt A; Cantillon, Marc; Cole, Patricia E; DeCarli, Charles; Dubois, Bruno; Duchesne, Simon; Fox, Nick C; Frisoni, Giovanni B; Hampel, Harald; Hill, Derek LG; Johnson, Keith; Mangin, Jean-François; Scheltens, Philip; Schwarz, Adam J; Sperling, Reisa; Suhy, Joyce; Thompson, Paul M; Weiner, Michael; Foster, Norman L
2012-01-01
Background The promise of Alzheimer’s disease (AD) biomarkers has led to their incorporation in new diagnostic criteria and in therapeutic trials; however, significant barriers exist to widespread use. Chief among these is the lack of internationally accepted standards for quantitative metrics. Hippocampal volumetry is the most widely studied quantitative magnetic resonance imaging (MRI) measure in AD and thus represents the most rational target for an initial effort at standardization. Methods and Results The authors of this position paper propose a path toward this goal. The steps include: 1) Establish and empower an oversight board to manage and assess the effort, 2) Adopt the standardized definition of anatomic hippocampal boundaries on MRI arising from the EADC-ADNI hippocampal harmonization effort as a Reference Standard, 3) Establish a scientifically appropriate, publicly available Reference Standard Dataset based on manual delineation of the hippocampus in an appropriate sample of subjects (ADNI), and 4) Define minimum technical and prognostic performance metrics for validation of new measurement techniques using the Reference Standard Dataset as a benchmark. Conclusions Although manual delineation of the hippocampus is the best available reference standard, practical application of hippocampal volumetry will require automated methods. Our intent is to establish a mechanism for credentialing automated software applications to achieve internationally recognized accuracy and prognostic performance standards that lead to the systematic evaluation and then widespread acceptance and use of hippocampal volumetry. The standardization and assay validation process outlined for hippocampal volumetry is envisioned as a template that could be applied to other imaging biomarkers. PMID:21784356
78 FR 21060 - Appeal Proceedings Before the Commission
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
... adoption of alternate standards from those required by the Commission's minimum internal control standards... adoption of alternate standards from those required by the Commission's minimum internal control standards... TGRAs' adoption of alternate standards from those required by the Commission's minimum internal control...
Mawson, Deborah H; Jeffrey, Keon L; Teale, Philip; Grace, Philip B
2018-06-19
A rapid, accurate and robust method for the determination of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg) and epigallocatechin gallate (EGCg) concentrations in human plasma has been developed. The method utilises protein precipitation following enzyme hydrolysis, with chromatographic separation and detection using reversed-phase liquid chromatography - tandem mass spectrometry (LC-MS/MS). Traditional issues such as lengthy chromatographic run times, sample and extract stability, and lack of suitable internal standards have been addressed. The method has been evaluated using a comprehensive validation procedure, confirming linearity over appropriate concentration ranges, and inter/intra batch precision and accuracies within suitable thresholds (precisions within 13.8% and accuracies within 12.4%). Recoveries of analytes were found to be consistent between different matrix samples, compensated for using suitable internal markers and within the performance of the instrumentation used. Similarly, chromatographic interferences have been corrected using the internal markers selected. Stability of all analytes in matrix is demonstrated over 32 days and throughout extraction conditions. This method is suitable for high throughput sample analysis studies. This article is protected by copyright. All rights reserved.
Treatment of Internet gaming disorder: An international systematic review and CONSORT evaluation.
King, Daniel L; Delfabbro, Paul H; Wu, Anise M S; Doh, Young Yim; Kuss, Daria J; Pallesen, Ståle; Mentzoni, Rune; Carragher, Natacha; Sakuma, Hiroshi
2017-06-01
Treatment services for Internet gaming disorder are becoming increasingly prevalent worldwide, particularly in East Asia. This international systematic review was designed to appraise the quality standards of the gaming disorder treatment literature, a task previously undertaken by King et al. (2011) prior to the inclusion of Internet gaming disorder in Section III of the DSM-5 and 'Gaming disorder' in the draft ICD-11. The reporting quality of 30 treatment studies conducted from 2007 to 2016 was assessed. Reporting quality was defined according to the 2010 Consolidating Standards of Reporting Trials (CONSORT) statement. The results reaffirmed previous criticisms of these trials, namely: (a) inconsistencies in the definition, diagnosis, and measurement of disordered use; (b) lack of randomization and blinding; (c) lack of controls; and (d) insufficient information on recruitment dates, sample characteristics, and effect sizes. Although cognitive-behavioral therapy has a larger evidence base than other therapies, it remains difficult to make definitive statements on its benefits. Study design quality has not improved over the last decade, indicating a need for greater consistency and standardization in this area. Continuing international efforts to understand the core psychopathology of gaming disorder are vital to developing a model of best practice in treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Carbonate and silicate rock standards for cosmogenic 36Cl
NASA Astrophysics Data System (ADS)
Mechernich, Silke; Dunai, Tibor J.; Binnie, Steven A.; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred; Benedetti, Lucilla; Schimmelpfennig, Irene; Phillips, Fred; Marrero, Shasta; Akif Sarıkaya, Mehmet; Gregory, Laura C.; Phillips, Richard J.; Wilcken, Klaus; Simon, Krista; Fink, David
2017-04-01
The number of studies using cosmogenic nuclides has increased multi-fold during the last two decades and several new dedicated target preparation laboratories and Accelerator Mass Spectrometry (AMS) facilities have been established. Each facility uses sample preparation and AMS measurement techniques particular to their needs. It is thus desirable to have community-accepted and well characterized rock standards available for routine processing using identical target preparation procedures and AMS measurement methods as carried out for samples of unknown cosmogenic nuclide concentrations. The usefulness of such natural standards is that they allow more rigorous quality control, for example, the long-term reproducibility of results and hence measurement precision, or the testing of new target preparation techniques or newly established laboratories. This is particularly pertinent for in-situ 36Cl studies due to the multiplicity of 36Cl production pathways that requires a variety of elemental and isotopic determinations in addition to AMS 36Cl assay. We have prepared two natural rock samples (denoted CoCal-N and CoFsp-N) to serve as standard material for in situ-produced cosmogenic 36Cl analysis. The sample CoCal-N is a pure limestone prepared from pebbles in a Namibian lag deposit, while the alkali-feldspar CoFsp-N is derived from a single crystal in a Namibian pegmatite. The sample preparation took place at the University of Cologne, where first any impurities were removed manually from both standards. CoCal-N was leached in 10 % HNO3 to remove the outer rim, and afterwards crushed and sieved to 250-500 μm size fractions. CoFsp-N was crushed, sieved to 250-500 μm size fractions and then leached in 1% HNO3 / 1% HF until 20% of the sample were removed. Both standards were thoroughly mixed using a rotating sample splitter before being distributed to other laboratories. To date, a total of 28 CoCal-N aliquots (between 2 and 16 aliquots per facility) and 31 CoFsp-N aliquots (between 2 and 20 aliquots per facility) have been analyzed by six target preparation laboratories employing five different AMS facilities. Currently, the internal reproducibility of the measurements underlines the homogeneity of both standards. The inter-laboratory comparison suggests low over-dispersion. Further measurements are pending and should allow meaningful statistical analysis. Both standard materials are freely available and can be obtained from Tibor Dunai tdunai@uni-koeln.de).
Canzani, Daniele; Hsieh, Kevin; Standland, Matthew; Hammack, Walter; Aldeek, Fadi
2017-02-15
Penicillin G has been applied to citrus trees as a potential treatment in the fight against Huanglongbing (HLB). Here, we have developed and validated a method to identify and quantitate penicillin G and two of its metabolites, penillic acid and penilloic acid, in citrus fruit using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). This method improves upon a previous method by incorporating isotopically labeled internal standards, namely, penillic acid-D 5 , and penilloic acid-D 5 . These standards greatly enhanced the accuracy and precision of our measurements by compensating for recovery losses, degradation, and matrix effects. When 2g of citrus fruit sample is extracted, the limits of detection (LOD) were determined to be 0.1ng/g for penicillin G and penilloic acid, and 0.25ng/g for penillic acid. At fortification levels of 0.1, 0.25, 1, and 10ng/g, absolute recoveries for penillic and penilloic acids were generally between 50-70%. Recoveries corrected with the isotopically labeled standards were approximately 90-110%. This method will be useful for the identification and quantitation of drug residues and their degradation products using isotopically labeled standards and UHPLC-MS/MS. Published by Elsevier B.V.
Determination of trace metals in drinking water in Irbid City-Northern Jordan.
Alomary, Ahmed
2013-02-01
Drinking water samples from Irbid, the second populated city in Jordan were analyzed for trace metals (As, Ba, Cd, Pb, Cr, Cu, Fe, Zn, Mn, Ni, and Se) content. The study was undertaken to determine if the metal concentrations were within the national and international guidelines. A total of 90 drinking water samples were collected from Al-Yarmouk University area. The samples were collected from three different water types: tap water (TW), home-purified water (HPW), and plant-purified water (PPW). All the samples were analyzed for trace metals using an inductively coupled plasma-optical emission spectrometry. All the samples analyzed were within the United States Environmental Protection Agency admissible pH limit (6.5-8.5). The results showed that concentrations of the trace metals vary significantly between the three drinking water types. The results showed that HPW samples have the lowest level of trace metals and the concentrations of some essential trace metals in these samples are less than the recommended amounts. Slight differences in the metal contents were found between HPW samples, little differences between PPW samples; however, significant differences were found between TW samples. Although some TW samples showed high levels of trace metals, however, the mean level of most elements determined in the samples were well within the Jordanian standards as well as the World Health Organization standards for drinking water.
Srivastava, Praveen; Moorthy, Ganesh S.; Gross, Robert; Barrett, Jeffrey S.
2013-01-01
A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC–MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and 13C6-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (13C6-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0–2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100–111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03–9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2–108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients. PMID:23755102
ERIC Educational Resources Information Center
Danziger, Sheldon
An overview of the level and distribution of income for a sample of Standard Metropolitan Statistical Areas (SMSAs) during the period 1959-1969, using data on pretax pretransfer incomes published by the Internal Revenue Service, is presented in this paper. Several results are described. (1) The level and distribution of income vary widely among…
Flint, Robert B; Bahmany, Soma; van der Nagel, Bart C H; Koch, Birgit C P
2018-05-16
A simple and specific UPLC-MS/MS method was developed and validated for simultaneous quantification of fentanyl, sufentanil, cefazolin, doxapram and its active metabolite keto-doxapram. The internal standard was fentanyl-d5 for all analytes. Chromatographic separation was achieved with a reversed phase Acquity UPLC HSS T3 column with a run-time of only 5.0 minutes per injected sample. Gradient elution was performed with a mobile phase consisting of ammonium acetate, formic acid in Milli-Q ultrapure water or in methanol with a total flow rate of 0.4 mL minute -1 . A plasma volume of only 50 μL was required to achieve both adequate accuracy and precision. Calibration curves of all 5 analytes were linear. All analytes were stable for at least 48 hours in the autosampler. The method was validated according to US Food and Drug Administration guidelines. This method allows quantification of fentanyl, sufentanil, cefazolin, doxapram and keto-doxapram, which serves purposes for research, as well as therapeutic drug monitoring, if applicable. The strength of this method is the combination of a small sample volume, a short run-time, a deuterated internal standard, an easy sample preparation method and the ability to simultaneously quantify all analytes in one run. This article is protected by copyright. All rights reserved.
Nazare, P; Massaroti, P; Duarte, L F; Campos, D R; Marchioretto, M A M; Bernasconi, G; Calafatti, S; Barros, F A P; Meurer, E C; Pedrazzoli, J; Moraes, L A B
2005-09-01
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.
McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R
2015-12-01
Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.
Chen, Xiabin; Zheng, Xirong; Ding, Kai; Zhou, Ziyuan; Zhan, Chang-Guo; Zheng, Fang
2016-01-01
As new metabolic pathways of cocaine were recently identified, a high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously determine cocaine and nine cocaine-related metabolites in whole blood samples. One-step solid phase extraction was used to extract all of the ten compounds and corresponding internal standards from blood samples. All compounds and internal standards extracted were separated on an Atlantis T3 (100Å, 3 µm, 2.1 mm × 150 mm I.D) column and detected in positive ion and high sensitivity mode with multiple reaction monitoring. This method was validated for its sensitivity, linearity, specificity, accuracy, precision, recovery, and stability. All of the ten compounds were quantifiable ranging from the lower limit of quantification (LLOQs) of ~10 nM (1.9–3.2 ng/ml) to ~1000 nM (190–320 ng/ml) without any interfering substance. Accuracy and precision were determined, and both of them were within the acceptance criteria of the United States (US) Food and Drug Administration (FDA) and European Medicines Agency (EMA) guidelines. The recovery was above 66.7% for all compounds. Stability tests demonstrated the stability of compounds under different storage conditions in whole blood samples. The method was successfully applied to a pharmacokinetic study with co-administration of cocaine and alcohol in rats. PMID:27923200
A new standard of visual data representation for imaging mass spectrometry.
O'Rourke, Matthew B; Padula, Matthew P
2017-03-01
MALDI imaging MS (IMS) is principally used for cancer diagnostics. In our own experience with publishing IMS data, we have been requested to modify our protocols with respect to the areas of the tissue that are imaged in order to comply with the wider literature. In light of this, we have determined that current methodologies lack effective controls and can potentially introduce bias by only imaging specific areas of the targeted tissue EXPERIMENTAL DESIGN: A previously imaged sample was selected and then cropped in different ways to show the potential effect of only imaging targeted areas. By using a model sample, we were able to effectively show how selective imaging of samples can misinterpret tissue features and by changing the areas that are acquired, according to our new standard, an effective internal control can be introduced. Current IMS sampling convention relies on the assumption that sample preparation has been performed correctly. This prevents users from checking whether molecules have moved beyond borders of the tissue due to delocalization and consequentially products of improper sample preparation could be interpreted as biological features that are of critical importance when encountered in a visual diagnostic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Krishna, A. Chaitanya; Sathiyaraj, M.; Saravanan, R. S.; Chelladurai, R.; Vignesh, R.
2012-01-01
A simple, rapid, specific and sensitive liquid chromatography tandem mass spectrometric method has been developed and validated for the determination of doxycycline from the human plasma. Doxycycline is extracted from human plasma by solid phase extraction. Demeclocycline was used as an internal standard. Detection was performed at transitions of 444.800→428.200 for doxycycline and 464.700→448.100 for demeclocycline using mass spectrometry. Chromatographic separation of analyte and internal standard were carried out using a reverse phase C18, column at 0.500 ml/min flow. The assay of doxycycline is linear over the range of 0.055-7.612 μg/ml, with a precision <14.83%, regression coefficient (r2)=0.9961 and the limit of quantification in plasma for doxycycline was 0.055 μg/ml. Mean extraction recovery obtained was 95.55%. Samples are stable at room temperature for 6 h, processed samples were stable at least for 30.20 h and also stable at three freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in human plasma. PMID:23798780
Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe
2014-09-01
Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.
NASA Technical Reports Server (NTRS)
James. John T.
2010-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (13C-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 93, 85%, and 88%, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 7 GSCs from the ISS is also shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 78, 96 and 90%, respectively. Recovery from formaldehyde control badges ranged from 90 to 112%.
Clinical applications of gas chromatograph/mass spectrometer/computer systems.
Horning, M G; Nowlin, J; Butler, C M; Lertratanangkoon, K; Sommer, K; Hill, R M
1975-08-01
Gas chromatograph/mass spectrometer/computer systems can be used to quantify a wide variety of compounds of clinical interest. A quadrupole instrument operated in the chemical ionization (Cl) mode was used in these studies. Because of the sensitivity and specificity of selective ion detection, it is possible to make measurements routinely in the nanogram to picogram range, with 0.1-1.0 ml samples of plasma and 1-5 ml samples or urine. Internal standards, preferably stable-isotope-labeled compounds, were added to the biological samples before isolation was begun. We describe clinical applications of these procedures to problems in toxicology, pharmacokinetics, and perinatal pharmacology.
Analysis of drugs in human tissues by supercritical fluid extraction/immunoassay
NASA Astrophysics Data System (ADS)
Furton, Kenneth G.; Sabucedo, Alberta; Rein, Joseph; Hearn, W. L.
1997-02-01
A rapid, readily automated method has been developed for the quantitative analysis of phenobarbital from human liver tissues based on supercritical carbon dioxide extraction followed by fluorescence enzyme immunoassay. The method developed significantly reduces sample handling and utilizes the entire liver homogenate. The current method yields comparable recoveries and precision and does not require the use of an internal standard, although traditional GC/MS confirmation can still be performed on sample extracts. Additionally, the proposed method uses non-toxic, inexpensive carbon dioxide, thus eliminating the use of halogenated organic solvents.
Ligugnana, Roberto
2017-01-01
Chapter <797> issued by the United States Pharmacopeial Convention, Inc. is the standard for sterile compounding. It is designed to reduce the number of patient infections due to contaminated pharmaceutical preparation. This regulation applies to all staff who prepare compounded sterile preparations and all places where they are produced, including hospitals, clinics, pharmacies, and physician's offices. This article provides the history of environmental microbiology and provides a discussion on environmental microbiology sampling of air for pharmaceutical sterile compounding. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Csomortáni, D Zoltán
2013-01-01
Preliminary research findings show that the parental rearing behaviour has a basic effect on the psychosocial development of the child, moreover, the inadequate parenting is related to some psychopathology occurring in childhood and adulthood. One reason in the development of this research subject was the appearance of the questionnaires, which judge the quality of the parenting and its effects by the children's recollections. Recently, there are new prospective instruments to remove the memory biases. The aim of this study was to standardize on a Hungarian sample one of these instruments, EMBU-C, made for primary school aged children. Primary school aged children (7-12 year old) were examined (n=108). Beyond demographic data the item base of the EMBU-C and the STAIC inventory were filled up. It was demonstrated the four factor structure of the EMBU-C (the names of the factors are respectively: Emotional warmth, Rejection, Overprotection and Favouring subject). The internal consistency of the inventory was in accordance with the international data. The concurrent validity also was proved by the STAIC. The recorded data are in accordance to the adolescent and adult versions of the EMBU. The most important result is that the parental rejection and overprotection may be related to the children's anxiety symptoms. Another important result is that the primary school aged children are disposed to interpret the intrusion component of the parental overprotection as emotional warmth that differs from adolescent and adult results. The successful standardization of the EMBU-C in Hungarian sample has positive consequences both to the clinical work and the research attempts, because it allows the investigation of the parental correlates of childhood psychopathologies, as well as the comparison of the results between different cohorts and international samples.
A new approach to counting measurements: Addressing the problems with ISO-11929
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klumpp, John Allan; Poudel, Deepesh; Miller, Guthrie
We present an alternative approach to making counting measurements of radioactivity which offers probabilistic interpretations of the measurements. Unlike the approach in the current international standard (ISO-11929), our approach, which uses an assumed prior probability distribution of the true amount in the sample, is able to answer the question of interest for most users of the standard: “what is the probability distribution of the true amount in the sample, given the data?” The final interpretation of the measurement requires information not necessarily available at the measurement stage. However, we provide an analytical formula for what we term the “measurement strength”more » that depends only on measurement-stage count quantities. Here, we show that, when the sources are rare, the posterior odds that the sample true value exceeds ε are the measurement strength times the prior odds, independently of ε, the prior odds, and the distribution of the calibration coefficient. We recommend that the measurement lab immediately follow-up on unusually high samples using an “action threshold” on the measurement strength which is similar to the decision threshold recommended by the current standard. Finally, we further recommend that the measurement lab perform large background studies in order to characterize non constancy of background, including possible time correlation of background.« less
A new approach to counting measurements: Addressing the problems with ISO-11929
Klumpp, John Allan; Poudel, Deepesh; Miller, Guthrie
2017-12-23
We present an alternative approach to making counting measurements of radioactivity which offers probabilistic interpretations of the measurements. Unlike the approach in the current international standard (ISO-11929), our approach, which uses an assumed prior probability distribution of the true amount in the sample, is able to answer the question of interest for most users of the standard: “what is the probability distribution of the true amount in the sample, given the data?” The final interpretation of the measurement requires information not necessarily available at the measurement stage. However, we provide an analytical formula for what we term the “measurement strength”more » that depends only on measurement-stage count quantities. Here, we show that, when the sources are rare, the posterior odds that the sample true value exceeds ε are the measurement strength times the prior odds, independently of ε, the prior odds, and the distribution of the calibration coefficient. We recommend that the measurement lab immediately follow-up on unusually high samples using an “action threshold” on the measurement strength which is similar to the decision threshold recommended by the current standard. Finally, we further recommend that the measurement lab perform large background studies in order to characterize non constancy of background, including possible time correlation of background.« less
A new approach to counting measurements: Addressing the problems with ISO-11929
NASA Astrophysics Data System (ADS)
Klumpp, John; Miller, Guthrie; Poudel, Deepesh
2018-06-01
We present an alternative approach to making counting measurements of radioactivity which offers probabilistic interpretations of the measurements. Unlike the approach in the current international standard (ISO-11929), our approach, which uses an assumed prior probability distribution of the true amount in the sample, is able to answer the question of interest for most users of the standard: "what is the probability distribution of the true amount in the sample, given the data?" The final interpretation of the measurement requires information not necessarily available at the measurement stage. However, we provide an analytical formula for what we term the "measurement strength" that depends only on measurement-stage count quantities. We show that, when the sources are rare, the posterior odds that the sample true value exceeds ε are the measurement strength times the prior odds, independently of ε, the prior odds, and the distribution of the calibration coefficient. We recommend that the measurement lab immediately follow-up on unusually high samples using an "action threshold" on the measurement strength which is similar to the decision threshold recommended by the current standard. We further recommend that the measurement lab perform large background studies in order to characterize non constancy of background, including possible time correlation of background.
Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method
ERIC Educational Resources Information Center
Bellamy, Michael K.
2010-01-01
The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…
Molecular epidemiology biomarkers-Sample collection and processing considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, Nina T.; Pfleger, Laura; Berger, Eileen
2005-08-07
Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less
Hopkins, Mark; Hau, Sarah; Tiernan, Caroline; Papadimitropoulos, Athanasios; Chawla, Anu; Beloukas, Apostolos; Geretti, Anna Maria
2015-08-01
Quantitative measurement of HIV-1 RNA levels in plasma ('viral load') plays a central role in clinical management. The choice of assay platform can influence results and treatment decisions. To compare the analytical performance of the new TMA-based Hologic Aptima(®) HIV-1 Quant Dx assay with that of three PCR-based assays: Abbott RealTime HIV-1, Qiagen Artus(®) HI Virus-1 QS-RGQ, and Roche CAP/CTM HIV-1 Test v2. Assay performance was evaluated using Acrometrix HIV-1 RNA Standard panels; the 3rd WHO HIV-1 RNA International Standard (12-500 copies/ml; 6 dilutions; 9 replicates); and plasma samples from 191 HIV-positive patients. Aptima showed high (>0.99) precision, accuracy and concordance with the Acrometrix Standards across a wide dynamic range (2.0-6.7 log10copies/ml). Variance caused up to 2.1 (Aptima), 1.7 (RealTime), 7.5 (Artus), and 1.9 (CAP/CTM) fold changes in the International Standard quantifications at 50-500 copies/ml. HIV-1 RNA detection rates in plasma samples were 141/191 (74%), 119/191 (62%), 108/191 (57%), and 145/191 (76%) for Aptima, RealTime, Artus and CAP/CTM, respectively. For categorising samples either side of 50 copies/ml, Aptima had excellent agreement with RealTime (kappa 0.92; 95% CI 0.87-0.98); lowest agreement was with Artus (kappa 0.79; 95%CI 0.70-0.88). Aptima quantifications were mean 0.12 and 0.06 log10copies/ml higher compared with RealTime and CAP/CTM, respectively, and 0.05 log10copies/ml lower compared with Artus. Limits of agreement were narrowest when comparing Aptima to RealTime. The new Aptima HIV assay is sensitive, precise, and accurate. HIV assays exhibit discordance at low HIV-1 RNA copy numbers. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T,; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2005-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.a; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2005-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space flight Center (MSFC) for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing testing standardization. To be discussed are: 1. Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debye lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Preventing sustained discharges during testing. 5. Real array or structure samples versus idealized samples. 6. Validity of LEO tests for GEO samples. 7. Extracting arc threshold information from arc rate versus voltage tests. 8 . Snapover and current collection at positive sample bias. Glows at positive bias. Kapton pyrolization. 9. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 10. Testing for Paschen discharge thresholds. Testing for dielectric breakdown thresholds. Testing for tether arcing. 11. Testing in very dense plasmas (ie thruster plumes). 12. Arc mitigation strategies. Charging mitigation strategies. Models. 13. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
Pang, Susan; Cowen, Simon
2017-12-13
We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.
Anand, K; Saini, Ks; Chopra, Y; Binod, Sk
2010-07-01
'Medical Devices' include everything from highly sophisticated, computerized, medical equipment, right down to simple wooden tongue depressors. Regulations embody the public expectations for how buildings and facilities are expected to perform and as such represent public policy. Regulators, who develop and enforce regulations, are empowered to act in the public's interest to set this policy and are ultimately responsible to the public in this regard. Standardization contributes to the basic infrastructure that underpins society including health and environment, while promoting sustainability and good regulatory practice. The international organizations that produce International Standards are the International Electrotechnical Commission (IEC), the International Organization for Standardization (ISO), and the International Telecommunication Union (ITU). With the increasing globalization of markets, International Standards (as opposed to regional or national standards) have become critical to the trading process, ensuring a level playing field for exports, and ensuring that imports meet the internationally recognized levels of performance and safety. The development of standards is done in response to sectors and stakeholders that express a clearly established need for them. An industry sector or other stakeholder group typically communicates its requirement for standards to one of the national members. To be accepted for development, a proposed work item must receive a majority support of the participating members, who verify the global relevance of the proposed item. The regulatory authority (RA) should provide a method for the recognition of international voluntary standards and for public notification of such recognition. The process of recognition may vary from country to country. Recognition may occur by periodic publication of lists of standards that a regulatory authority has found will meet the Essential Principles. In conclusion, International standards, such as, basic standards, group standards, and product standards, are a tool for harmonizing regulatory processes, to assure the safety, quality, and performance of medical devices. Standards represent the opinion of experts from all interested parties, including industry, regulators, users, and others.
Zapata-Vanegas, Mario A
2014-01-01
Characterizing and contrasting the current state of affairs concerning patients' rights-associated accreditation standards in a sample of drug-addiction treatment centers in Colombia. This was mixed methodology research (i.e. descriptive and hermeneutic); a pilot sample of 21 drug-addiction treatment centers in Colombia was used for determining the current state of patients' rights accreditation standards. The possible relationship or independence between categorical variables was evaluated by using Fisher's exact test (0.05 significance level). A contrasting documentary review was made at the same time. Drug-addiction treatment centers provided more information for families (95 %) than patients (90 %) or minors (81 %). Possible barriers to gaining access for treatment were being HIV positive (29 %), being part of the LGTB population (14 %) and being female (10 %); religion and ethnicity were not seen as grounds for discrimination or treatment barriers. The patients' rights standards group coincided with Colombia's accreditation system and Joint Commission standards; however, the latter accreditation entity has made significant progress regarding a specific manual for drug-addiction treatment centers. The centers assessed in Colombia had made advances regarding accrediting patients' rights, but such standards require revision for being adapted to international developments and specific matters involved in treating addicts and the specific conditions for institutions dealing with such treatment.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...
Determination of microbial phenolic acids in human faeces by UPLC-ESI-TQ MS.
Sánchez-Patán, Fernando; Monagas, María; Moreno-Arribas, M Victoria; Bartolomé, Begoña
2011-03-23
The aim of the present work was to develop a reproducible, sensitive, and rapid UPLC-ESI-TQ MS analytical method for determination of microbial phenolic acids and other related compounds in faeces. A total of 47 phenolic compounds including hydroxyphenylpropionic, hydroxyphenylacetic, hydroxycinnamic, hydroxybenzoic, and hydroxymandelic acids and simple phenols were considered. To prepare an optimum pool standard solution, analytes were classified in 5 different groups with different starting concentrations according to their MS response. The developed UPLC method allowed a high resolution of the pool standard solution within an 18 min injection run time. The LOD of phenolic compounds ranged from 0.001 to 0.107 μg/mL and LOQ from 0.003 to 0.233 μg/mL. The method precision met acceptance criteria (<15% RSD) for all analytes, and accuracy was >80%. The method was applied to faecal samples collected before and after the intake of a flavan-3-ol supplement by a healthy volunteer. Both external and internal calibration methods were considered for quantification purposes, using 4-hydroxybenzoic-2,3,4,5-d4 acid as internal standard. For most analytes and samples, the level of microbial phenolic acids did not differ by using one or another calibration method. The results revealed an increase in protocatechuic, syringic, benzoic, p-coumaric, phenylpropionic, 3-hydroxyphenylacetic, and 3-hydroxyphenylpropionic acids, although differences due to the intake were only significant for the latter compound. In conclusion, the UPLC-DAD-ESI-TQ MS method developed is suitable for targeted analysis of microbial-derived phenolic metabolites in faecal samples from human intervention or in vitro fermentation studies, which requires high sensitivity and throughput.
Metadata, Identifiers, and Physical Samples
NASA Astrophysics Data System (ADS)
Arctur, D. K.; Lenhardt, W. C.; Hills, D. J.; Jenkyns, R.; Stroker, K. J.; Todd, N. S.; Dassie, E. P.; Bowring, J. F.
2016-12-01
Physical samples are integral to much of the research conducted by geoscientists. The samples used in this research are often obtained at significant cost and represent an important investment for future research. However, making information about samples - whether considered data or metadata - available for researchers to enable discovery is difficult: a number of key elements related to samples are difficult to characterize in common ways, such as classification, location, sample type, sampling method, repository information, subsample distribution, and instrumentation, because these differ from one domain to the next. Unifying these elements or developing metadata crosswalks is needed. The iSamples (Internet of Samples) NSF-funded Research Coordination Network (RCN) is investigating ways to develop these types of interoperability and crosswalks. Within the iSamples RCN, one of its working groups, WG1, has focused on the metadata related to physical samples. This includes identifying existing metadata standards and systems, and how they might interoperate with the International Geo Sample Number (IGSN) schema (schema.igsn.org) in order to help inform leading practices for metadata. For example, we are examining lifecycle metadata beyond the IGSN `birth certificate.' As a first step, this working group is developing a list of relevant standards and comparing their various attributes. In addition, the working group is looking toward technical solutions to facilitate developing a linked set of registries to build the web of samples. Finally, the group is also developing a comparison of sample identifiers and locators. This paper will provide an overview and comparison of the standards identified thus far, as well as an update on the technical solutions examined for integration. We will discuss how various sample identifiers might work in complementary fashion with the IGSN to more completely describe samples, facilitate retrieval of contextual information, and access research work on related samples. Finally, we welcome suggestions and community input to move physical sample unique identifiers forward.
Improved DESI-MS Performance using Edge Sampling and aRotational Sample Stage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kertesz, Vilmos; Van Berkel, Gary J
2008-01-01
The position of the surface to be analyzed relative to the sampling orifice or capillary into the mass spectrometer has been known to dramatically affect the observed signal levels in desorption electrospray ionization mass spectrometry (DESIMS). In analyses of sample spots on planar surfaces, DESI-MS signal intensities as much as five times greater were routinely observed when the bottom of the sampling capillary was appropriately positioned beneath the surface plane ( edge sampling") compared to when the capillary just touched the surface. To take advantage of the optimum "edge sampling" geometry and to maximize the number of samples that couldmore » be analyzed in this configuration, a rotational sample stage was integrated into a typical DESI-MS setup. The rapid quantitative determination of caffeine in two diet sport drinks (Diet Turbo Tea, Speed Stack Grape) spiked with an isotopically labeled internal standard demonstrated the utility of this approach.« less
Shulman, Stanley A.; Brisson, Michael J.; Howe, Alan M.
2015-01-01
Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter−1, with three different filter loadings denoted “Low”, “Medium” and “High”. Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter−1. Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study. PMID:22038017
Papp, Robert; Luk, Pauline; Mullett, Wayne M; Kwong, Elizabeth
2007-10-15
A rapid LC-MS/MS method was developed and partially validated for the quantitation of montelukast in spiked sheep plasma. A total run time of 1.5 min was achieved using a short monolithic column and employing a rapid gradient. Sample preparation involved protein precipitation with twofold acetonitrile by volume during which a deuterated internal standard (montelukast D-6) was incorporated. The MRM transitions for montelukast and the deuterated internal standard were 586/422 and 592/427, respectively. A linear dynamic range of 0.25-500 ng/mL with a correlation coefficient of 0.9999 was achieved. Precision was below 5% at all levels except at the LOQ (0.36 ng/mL) which demonstrated an overall of R.S.D. of 8%. Post-column infusion experiments were performed with precipitated plasma matrix and showed minimal interference with the peaks of interest.
High pressure liquid chromatography of zearalenone and zearalenols in rat urine and liver.
James, L J; McGirr, L G; Smith, T K
1982-01-01
A high pressure liquid chromatographic technique with internal standardization has been developed for determining zearalenone and metabolites in rat urine and liver. Following extraction with methylene chloride and solvent partition, samples are cleaned up by applying the extract to a Sephadex LH-20 column and eluting with a mixture of benzene-methanol (85 + 15). Compounds were resolved on 2 Part-isil-10 columns (25 cm x 4.6 mm id) in series with a mobile phase of isooctane-chloroform-methanol (35 + 25 + 3), and detected at 280 nm. The internal standard was 6'alpha-acetoxyzearalane. Limits of detection were about 2.0 ng for zearalenone and 5.0 ng for zearalenols (6'-hydroxyzearalane). Zearalenone and zearalenols were excreted mainly in free form with relatively little glucuronide conjugation. Metabolism of zearalenone to free zearalenol was minor compared with formation of bound forms.
Successful amplification of DNA aboard the International Space Station.
Boguraev, Anna-Sophia; Christensen, Holly C; Bonneau, Ashley R; Pezza, John A; Nichols, Nicole M; Giraldez, Antonio J; Gray, Michelle M; Wagner, Brandon M; Aken, Jordan T; Foley, Kevin D; Copeland, D Scott; Kraves, Sebastian; Alvarez Saavedra, Ezequiel
2017-01-01
As the range and duration of human ventures into space increase, it becomes imperative that we understand the effects of the cosmic environment on astronaut health. Molecular technologies now widely used in research and medicine will need to become available in space to ensure appropriate care of astronauts. The polymerase chain reaction (PCR) is the gold standard for DNA analysis, yet its potential for use on-orbit remains under-explored. We describe DNA amplification aboard the International Space Station (ISS) through the use of a miniaturized miniPCR system. Target sequences in plasmid, zebrafish genomic DNA, and bisulfite-treated DNA were successfully amplified under a variety of conditions. Methylation-specific primers differentially amplified bisulfite-treated samples as would be expected under standard laboratory conditions. Our findings establish proof of concept for targeted detection of DNA sequences during spaceflight and lay a foundation for future uses ranging from environmental monitoring to on-orbit diagnostics.
Evans, D. G.; Perkins, F. T.
1963-01-01
The Fifth International Standard Gas-Gangrene Antitoxin (Perfringens) (Clostridium welchii Type A Antitoxin) was prepared from serum from immunized horses. It was freeze-dried in ampoules each containing 1 ml. Seven laboratories collaborated in assaying its potency in terms of the Fourth International Standard by the intravenous inoculation of mice. The geometric mean value, taking the results of all the laboratories, was 270 International Units per ampoule and the maximum variation between laboratories was 15%. In vitro (lecithinase) tests were also done by three laboratories, giving an average of 261 International Units per ampoule. The dry weight contents of ampoules, determined in three laboratories, varied by less than 3%, with an average of 90.35 mg per ampoule. The standard was stable for 120 hours at 56°C. Each ampoule of the Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens) contains 270 International Units, and one International Unit is contained in 0.3346 mg of the International Standard. PMID:14107745
The second international standard for polymyxin B.
Lightbown, J W; Thomas, A H; Grab, B; Outschoorn, A S
1973-01-01
Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard.
The second international standard for polymyxin B*
Lightbown, J. W.; Thomas, A. H.; Grab, B.; Outschoorn, A. S.
1973-01-01
Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard. PMID:4350877
Salerno, Stephen M; Arnett, Michael V; Domanski, Jeremy P
2009-01-01
Prior research on reducing variation in housestaff handoff procedures have depended on proprietary checkout software. Use of low-technology standardization techniques has not been widely studied. We wished to determine if standardizing the process of intern sign-out using low-technology sign-out tools could reduce perception of errors and missing handoff data. We conducted a pre-post prospective study of a cohort of 34 interns on a general internal medicine ward. Night interns coming off duty and day interns reassuming care were surveyed on their perception of erroneous sign-out data, mistakes made by the night intern overnight, and occurrences unanticipated by sign-out. Trainee satisfaction with the sign-out process was assessed with a 5-point Likert survey. There were 399 intern surveys performed 8 weeks before and 6 weeks after the introduction of a standardized sign-out form. The response rate was 95% for the night interns and 70% for the interns reassuming care in the morning. After the standardized form was introduced, night interns were significantly (p < .003) less likely to detect missing sign-out data including missing important diseases, contingency plans, or medications. Standardized sign-out did not significantly alter the frequency of dropped tasks or missed lab and X-ray data as perceived by the night intern. However, the day teams thought there were significantly less perceived errors on the part of the night intern (p = .001) after introduction of the standardized sign-out sheet. There was no difference in mean Likert scores of resident satisfaction with sign-out before and after the intervention. Standardized written sign-out sheets significantly improve the completeness and effectiveness of handoffs between night and day interns. Further research is needed to determine if these process improvements are related to better patient outcomes.
Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.
Carter, J F; Fry, B
2013-03-01
The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.
Use of probability analysis to establish routine bioassay screening levels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, E.H.; Sula, M.J.; McFadden, K.M.
1990-09-01
Probability analysis was used by the Hanford Internal Dosimetry Program to establish bioassay screening levels for tritium and uranium in urine. Background environmental levels of these two radionuclides are generally detectable by the highly sensitive urine analysis procedures routinely used at Hanford. Establishing screening levels requires balancing the impact of false detection with the consequence of potentially undetectable occupation dose. To establish the screening levels, tritium and uranium analyses were performed on urine samples collected from workers exposed only to environmental sources. All samples were collected at home using a simulated 12-hour protocol for tritium and a simulated 24-hour collectionmore » protocol for uranium. Results of the analyses of these samples were ranked according to tritium concentration or total sample uranium. The cumulative percentile was calculated and plotted using log-probability coordinates. Geometric means and screening levels corresponding to various percentiles were estimated by graphical interpolation and standard calculations. The potentially annual internal dose associated with a screening level was calculated. Screening levels were selected corresponding to the 99.9 percentile, implying that, on the average, 1 out of 1000 samples collected from an unexposed worker population would be expected to exceed the screening level. 4 refs., 2 figs.« less
Marcillo, Andrea; Jakimovska, Viktorija; Widdig, Anja; Birkemeyer, Claudia
2017-09-08
Volatile organic compounds (VOCs) are commonly collected from gaseous samples by adsorption to materials such as the porous polymer Tenax TA. Adsorbed compounds are subsequently released from these materials by thermal desorption (TD) and separated then by gas chromatography (GC) with flame ionization (FID) or mass spectrometry (MS) detection. Tenax TA is known to be particularly suitable for non-polar to semipolar volatiles, however, many volatiles from environmental and biological samples possess a rather polar character. Therefore, we tested if the polymer XAD-2, which so far is widely used to adsorb organic compounds from aqueous and organic solvents, could provide a broader coverage for (semi)polar VOCs during gas-phase sampling. Mixtures of volatile compounds covering a wide range of volatility (bp. 20-256°C) and different chemical classes were introduced by liquid spiking into sorbent tubes with one of the two porous polymers, Tenax TA or XAD-2, and analyzed by TD/GC-MS. At first, an internal standard mixture composed of 17 authentic standards was used to optimize desorption temperature with respect to sorbent degradation and loading time for calibration. Secondly, we tested the detectability of a complex standard mixture composed of 57 volatiles, most of them common constituents of the body odor of mammals. Moreover, the performance of XAD-2 compared with Tenax TA was assessed as limit of quantitation and linearity for the internal standard mixture and 33 compounds from the complex standard mixture. Volatiles were analyzed in a range between 0.01-∼250ng/tube depending on the compound and material. Lower limits of quantitation were between 0.01 and 3 ng±<25% RSD (R 2 >0.9). Interestingly, we found different kinetics for compound adsorption with XAD-2, and a partially better sensitivity in comparison with Tenax TA. For these analytes, XAD-2 might be recommended as an alternative of Tenax TA for TD/GC-MS analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto
2015-02-01
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.
Levy, J K; Crawford, P Cynda; Tucker, S J
2017-03-01
More than 3 million cats in the United States are infected with FeLV or FIV. The cornerstone of control is identification and segregation of infected cats. To compare test performance with well-characterized clinical samples of currently available FeLV antigen/FIV antibody combination test kits. Surplus serum and plasma from diagnostic samples submitted by animal shelters, diagnostic laboratories, veterinary clinics, and cat research colonies. None of the cats had been vaccinated against FIV. The final sample set included 146 FeLV+, 154 FeLV-, 94 FIV+, and 97 FIV- samples. Prospective, blind comparison to a gold standard: Samples were evaluated in 4 different point-of-care tests by ELISA antigen plate tests (FeLV) and virus isolation (FIV) as the reference standards. All test results were visually read by 2 blinded observers. Sensitivity and specificity, respectively, for FeLV were SNAP ® (100%/100%), WITNESS ® (89.0%/95.5%), Anigen ® (91.8%/95.5%), and VetScan ® (85.6%/85.7%). Sensitivity and specificity for FIV were SNAP ® (97.9%/99.0%), WITNESS ® (94.7%/100%), Anigen ® (96.8%/99.0%), and VetScan ® (91.5%/99.0%). The SNAP ® test had the best performance for FeLV, but there were no significant differences for FIV. In typical cat populations with seroprevalence of 1-5%, a majority of positive results reported by most point-of-care test devices would be false-positives. This could result in unnecessary segregation or even euthanasia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Ramakumar, Adarsh; Subramanian, Uma; Prasanna, Pataje G S
2015-11-01
High-throughput individual diagnostic dose assessment is essential for medical management of radiation-exposed subjects after a mass casualty. Cytogenetic assays such as the Dicentric Chromosome Assay (DCA) are recognized as the gold standard by international regulatory authorities. DCA is a multi-step and multi-day bioassay. DCA, as described in the IAEA manual, can be used to assess dose up to 4-6 weeks post-exposure quite accurately but throughput is still a major issue and automation is very essential. The throughput is limited, both in terms of sample preparation as well as analysis of chromosome aberrations. Thus, there is a need to design and develop novel solutions that could utilize extensive laboratory automation for sample preparation, and bioinformatics approaches for chromosome-aberration analysis to overcome throughput issues. We have transitioned the bench-based cytogenetic DCA to a coherent process performing high-throughput automated biodosimetry for individual dose assessment ensuring quality control (QC) and quality assurance (QA) aspects in accordance with international harmonized protocols. A Laboratory Information Management System (LIMS) is designed, implemented and adapted to manage increased sample processing capacity, develop and maintain standard operating procedures (SOP) for robotic instruments, avoid data transcription errors during processing, and automate analysis of chromosome-aberrations using an image analysis platform. Our efforts described in this paper intend to bridge the current technological gaps and enhance the potential application of DCA for a dose-based stratification of subjects following a mass casualty. This paper describes one such potential integrated automated laboratory system and functional evolution of the classical DCA towards increasing critically needed throughput. Published by Elsevier B.V.
Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina
2014-10-01
The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry.
Lee, Hye Won; Ji, Hye Young; Kim, Hee Hyun; Cho, Hea-Young; Lee, Yong-Bok; Lee, Hye Suk
2003-11-05
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.
Precise determination of N-acetylcysteine in pharmaceuticals by microchip electrophoresis.
Rudašová, Marína; Masár, Marián
2016-01-01
A novel microchip electrophoresis method for the rapid and high-precision determination of N-acetylcysteine, a pharmaceutically active ingredient, in mucolytics has been developed. Isotachophoresis separations were carried out at pH 6.0 on a microchip with conductivity detection. The methods of external calibration and internal standard were used to evaluate the results. The internal standard method effectively eliminated variations in various working parameters, mainly run-to-run fluctuations of an injected volume. The repeatability and accuracy of N-acetylcysteine determination in all mucolytic preparations tested (Solmucol 90 and 200, and ACC Long 600) were more than satisfactory with the relative standard deviation and relative error values <0.7 and <1.9%, respectively. A recovery range of 99-101% of N-acetylcysteine in the analyzed pharmaceuticals predetermines the proposed method for accurate analysis as well. This work, in general, indicates analytical possibilities of microchip isotachophoresis for the quantitative analysis of simplified samples such as pharmaceuticals that contain the analyte(s) at relatively high concentrations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bismuth as a general internal standard for lead in atomic absorption spectrometry.
Bechlin, Marcos A; Fortunato, Felipe M; Ferreira, Edilene C; Gomes Neto, José A; Nóbrega, Joaquim A; Donati, George L; Jones, Bradley T
2014-06-11
Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A(Pb)/A(Bi)versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52-118% (without IS) to 97-109% (IS, LS FAAS); 74-231% (without IS) to 96-109% (IS, HR-CS FAAS); and 36-125% (without IS) to 96-110% (IS, LS GFAAS). The relative standard deviations (n=12) were reduced from 0.6-9.2% (without IS) to 0.3-4.3% (IS, LS FAAS); 0.7-7.7% (without IS) to 0.1-4.0% (IS, HR-CS FAAS); and 2.1-13% (without IS) to 0.4-5.9% (IS, LS GFAAS). Copyright © 2014 Elsevier B.V. All rights reserved.
Assessment of the iodine concentration in table salt at the production stage in South Africa.
Jooste, Pieter L.
2003-01-01
OBJECTIVE: To determine the iodine content of iodized salt at the production stage, to assess the perceptions and knowledge of salt producers about the prevention and control of iodine deficiency, and to examine the internal quality control procedures used during iodization in South Africa. METHOD: Salt samples were collected for iodine analysis by titration from the 12 producers iodizing salt in South Africa. Information on the producers' knowledge of iodine deficiency disorders and on internal quality control was obtained by means of questionnaires. FINDINGS: The legal requirement of 40-60 ppm iodine was met in 30.9% of salt samples; 57.9% contained more than 30 ppm iodine; 34.8% contained under 20 ppm iodine. There were shortcomings in perceptions and knowledge about iodine deficiency disorders and in the internal quality control procedures of a substantial proportion of the producers. CONCLUSION: In order to encourage and support salt producers to achieve optimal iodization there should be an information, education and communication strategy aimed at improving knowledge of iodine deficiency disorders and at raising the standard of internal quality control procedures. External monitoring should continue. PMID:12973644
Spaun, J.; Lyng, J.
1970-01-01
Since 1935 the International Unit for Tetanus Antitoxin has been defined as the activity contained in a certain weight of the first International Standard for Tetanus Antitoxin. As stocks of this standard had become depleted, 11 laboratories in 8 countries were requested to participate in a collaborative assay of a preparation proposed as a replacement. The assay results were analysed and presented to the WHO Expert Committee on Biological Standardization in 1969 which established the preparation studied as the second International Standard for Tetanus Antitoxin and defined the International Unit for Tetanus Antitoxin as the activity contained in 0.03384 mg of the second International Standard for Tetanus Antitoxin. This definition would ensure the continuity of the size of this international unit. The analysis of the collaborative studies also showed that the second International Standard for Tetanus Antitoxin has suitable properties for use in the flocculation test for the determination of the antigen content of tetanus toxoids in Lf values. The designation Lf-equivalent is described and the problems relating to the use of this term for the expression of results of in vitro assays are analysed in relation to the use of international units for expressing results of in vivo assays. As the second International Standard for Tetanus Antitoxin has an in vivo/in vitro ratio of 1.4, the Lf-equivalent of this antitoxin is 1.4 times less than its unitage. PMID:5310949
Van Berkel, Gary J; Kertesz, Vilmos; Boeltz, Harry
2017-11-01
The aim of this work was to demonstrate and evaluate the analytical performance of coupling the immediate drop on demand technology to a mass spectrometer via the recently introduced open port sampling interface and ESI. Methodology & results: A maximum sample analysis throughput of 5 s per sample was demonstrated. Signal reproducibility was 10% or better as demonstrated by the quantitative analysis of propranolol and its stable isotope-labeled internal standard propranolol-d7. The ability of the system to multiply charge and analyze macromolecules was demonstrated using the protein cytochrome c. This immediate drop on demand technology/open port sampling interface/ESI-MS combination allowed for the quantitative analysis of relatively small mass analytes and was used for the identification of macromolecules like proteins.
Comparison of RFFIT tests with different standard sera and testing procedures.
Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong
2012-06-01
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.
25 CFR 542.14 - What are the minimum internal control standards for the cage?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for the cage? 542.14 Section 542.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.14 What are the minimum internal control standards for the cage? (a) Computer applications. For...
25 CFR 543.8 - What are the minimum internal control standards for bingo?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 543.8 - What are the minimum internal control standards for bingo?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...
Rule, Geoffrey S; Clark, Zlatuse D; Yue, Bingfang; Rockwood, Alan L
2013-04-16
Stable isotope-labeled internal standards are of great utility in providing accurate quantitation in mass spectrometry (MS). An implicit assumption has been that there is no "cross talk" between signals of the internal standard and the target analyte. In some cases, however, naturally occurring isotopes of the analyte do contribute to the signal of the internal standard. This phenomenon becomes more pronounced for isotopically rich compounds, such as those containing sulfur, chlorine, or bromine, higher molecular weight compounds, and those at high analyte/internal standard concentration ratio. This can create nonlinear calibration behavior that may bias quantitative results. Here, we propose the use of a nonlinear but more accurate fitting of data for these situations that incorporates one or two constants determined experimentally for each analyte/internal standard combination and an adjustable calibration parameter. This fitting provides more accurate quantitation in MS-based assays where contributions from analyte to stable labeled internal standard signal exist. It can also correct for the reverse situation where an analyte is present in the internal standard as an impurity. The practical utility of this approach is described, and by using experimental data, the approach is compared to alternative fits.
Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène
2015-05-01
The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.
Lloyd, T L; Perschy, T B; Gooding, A E; Tomlinson, J J
1992-01-01
A fully automated assay for the analysis of ranitidine in serum and plasma, with and without an internal standard, was validated. It utilizes robotic solid phase extraction with on-line high performance liquid chromatographic (HPLC) analysis. The ruggedness of the assay was demonstrated over a three-year period. A Zymark Py Technology II robotic system was used for serial processing from initial aspiration of samples from original collection containers, to final direct injection onto the on-line HPLC system. Automated serial processing with on-line analysis provided uniform sample history and increased productivity by freeing the chemist to analyse data and perform other tasks. The solid phase extraction efficiency was 94% throughout the assay range of 10-250 ng/mL. The coefficients of variation for within- and between-day quality control samples ranged from 1 to 6% and 1 to 5%, respectively. Mean accuracy for between-day standards and quality control results ranged from 97 to 102% of the respective theoretical concentrations.
Zazzi, Barbara C.; Crepeau, Kathryn L.; Fram, Miranda S.; Bergamaschi, Brian A.
2005-01-01
An analytical method for the determination of haloacetic acid formation potential of water samples has been developed by the U.S. Geological Survey California Water Science Center Sacramento Laboratory. The haloacetic acid formation potential is measured by dosing water samples with chlorine under specified conditions of pH, temperature, incubation time, darkness, and residual-free chlorine. The haloacetic acids formed are bromochloroacetic acid, bromodichloroacetic acid, dibromochloroacetic acid, dibromoacetic acid, dichloroacetic acid, monobromoacetic acid, monochloroacetic acid, tribromoacetic acid, and trichloroacetic acid. They are extracted, methylated, and then analyzed using a gas chromatograph equipped with an electron capture detector. Method validation experiments were performed to determine the method accuracy, precision, and detection limit for each of the compounds. Method detection limits for these nine haloacetic acids ranged from 0.11 to 0.45 microgram per liter. Quality-control practices include the use of blanks, quality-control samples, calibration verification standards, surrogate recovery, internal standard, matrix spikes, and duplicates.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham
2011-09-01
A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.
Determination of organochlorine pesticides in skins and leather by gas chromatography.
Font, J; Marsal, A
1998-06-19
The simultaneous determination of residues of lindane (gamma-HCH) and 10 other organochlorine pesticides (OCPs) in skins and leather was carried out by gas chromatography (GC) with electron-capture detection (ECD). GC with mass spectrometric detection was used to identity confirmation. Samples were extracted with hexane. The extracts were concentrated, and cleaned up on a Florisil column. Dibromooctafluorobiphenyl was added as internal standard. Hide fortifications of 0.5 an d5.0 ppm yielded average lindane recoveries of 98% and 96%, respectively. OCPs was determined in 57 samples of skins purchased from American, European and African countries in 1996-1997. OCPs were not detected in any of the American and European samples. Residues of lindane were found in 56% of African samples.
2014-01-01
Over the last decade the amino acid beta-N-methylamino-L-alanine (BMAA) has come under intense scrutiny. International laboratory and epidemiological research continues to support the hypothesis that environmental exposure to BMAA (e.g., through dietary practices, water supply) can promote the risk of various neurodegenerative diseases. A wide variety of cyanobacteria spp. have previously been reported to produce BMAA, with production levels dependent upon species, strain and environmental conditions. Since spirulina (Arthrospira spp.) is a member of the cyanobacteria phylum frequently consumed via dietary supplements, the presence of BMAA in such products may have public health implications. In the current work, we have analyzed ten spirulina-containing samples for the presence of BMAA; six pure spirulina samples from two separate raw materials suppliers, and four commercially-available multi-ingredient products containing 1.45 g of spirulina per 8.5 g serving. Because of controversy surrounding the measurement of BMAA, we have used two complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods: one based on reversed phase LC (RPLC) with derivatization and the other based on hydrophilic interaction LC (HILIC). Potential matrix effects were corrected for by internal standardization using a stable isotope labeled BMAA standard. BMAA was not detected at low limits of detection (80 ng/g dry weight) in any of these product samples. Although these results are reassuring, BMAA analyses should be conducted on a wider sample selection and, perhaps, as part of ongoing spirulina production quality control testing and specifications. PMID:25120905
High-Throughput Quantitation of Neonicotinoids in Lyophilized Surface Water by LC-APCI-MS/MS.
Morrison, Lucas M; Renaud, Justin B; Sabourin, Lyne; Sumarah, Mark W; Yeung, Ken K C; Lapen, David R
2018-05-21
Background : Neonicotinoids are among the most widely used insecticides. Recently, there has been concern associated with unintended adverse effects on honeybees and aquatic invertebrates at low parts-per-trillion levels. Objective : There is a need for LC-MS/MS methods that are capable of high-throughput measurements of the most widely used neonicotinoids at environmentally relevant concentrations in surface water. Methods : This method allows for quantitation of acetamiprid, clothianidin, imidacloprid, dinotefuran, nitenpyram, thiacloprid, and thiamethoxam in surface water. Deuterated internal standards are added to 20 mL environmental samples, which are concentrated by lyophilisation and reconstituted with methanol followed by acetonitrile. Results : A large variation of mean recovery efficiencies across five different surface water sampling sites within this study was observed, ranging from 45 to 74%. This demonstrated the need for labelled internal standards to compensate for these differences. Atmospheric pressure chemical ionization (APCI) performed better than electrospray ionization (ESI) with limited matrix suppression, achieving 71-110% of the laboratory fortified blank signal. Neonicotinoids were resolved on a C18 column using a 5 min LC method, in which MQL ranged between 0.93 and 4.88 ng/L. Conclusions : This method enables cost effective, accurate, and reproducible monitoring of these pesticides in the aquatic environment. Highlights : Lyophilization is used for high throughput concentration of neonicotinoids in surface water. Variations in matrix effects between samples was greatly reduced by using APCI compared with ESI. Clothianidin and thiamethoxam were detected in all samples with levels ranging from below method quantitation limit to 65 ng/L.
McCarron, Pearse; Logan, Alan C; Giddings, Sabrina D; Quilliam, Michael A
2014-01-01
Over the last decade the amino acid beta-N-methylamino-L-alanine (BMAA) has come under intense scrutiny. International laboratory and epidemiological research continues to support the hypothesis that environmental exposure to BMAA (e.g., through dietary practices, water supply) can promote the risk of various neurodegenerative diseases. A wide variety of cyanobacteria spp. have previously been reported to produce BMAA, with production levels dependent upon species, strain and environmental conditions. Since spirulina (Arthrospira spp.) is a member of the cyanobacteria phylum frequently consumed via dietary supplements, the presence of BMAA in such products may have public health implications. In the current work, we have analyzed ten spirulina-containing samples for the presence of BMAA; six pure spirulina samples from two separate raw materials suppliers, and four commercially-available multi-ingredient products containing 1.45 g of spirulina per 8.5 g serving. Because of controversy surrounding the measurement of BMAA, we have used two complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods: one based on reversed phase LC (RPLC) with derivatization and the other based on hydrophilic interaction LC (HILIC). Potential matrix effects were corrected for by internal standardization using a stable isotope labeled BMAA standard. BMAA was not detected at low limits of detection (80 ng/g dry weight) in any of these product samples. Although these results are reassuring, BMAA analyses should be conducted on a wider sample selection and, perhaps, as part of ongoing spirulina production quality control testing and specifications.
Blinded sample size re-estimation in three-arm trials with 'gold standard' design.
Mütze, Tobias; Friede, Tim
2017-10-15
In this article, we study blinded sample size re-estimation in the 'gold standard' design with internal pilot study for normally distributed outcomes. The 'gold standard' design is a three-arm clinical trial design that includes an active and a placebo control in addition to an experimental treatment. We focus on the absolute margin approach to hypothesis testing in three-arm trials at which the non-inferiority of the experimental treatment and the assay sensitivity are assessed by pairwise comparisons. We compare several blinded sample size re-estimation procedures in a simulation study assessing operating characteristics including power and type I error. We find that sample size re-estimation based on the popular one-sample variance estimator results in overpowered trials. Moreover, sample size re-estimation based on unbiased variance estimators such as the Xing-Ganju variance estimator results in underpowered trials, as it is expected because an overestimation of the variance and thus the sample size is in general required for the re-estimation procedure to eventually meet the target power. To overcome this problem, we propose an inflation factor for the sample size re-estimation with the Xing-Ganju variance estimator and show that this approach results in adequately powered trials. Because of favorable features of the Xing-Ganju variance estimator such as unbiasedness and a distribution independent of the group means, the inflation factor does not depend on the nuisance parameter and, therefore, can be calculated prior to a trial. Moreover, we prove that the sample size re-estimation based on the Xing-Ganju variance estimator does not bias the effect estimate. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Data Management and Rescue at a State Geological Survey
NASA Astrophysics Data System (ADS)
Hills, D. J.; McIntyre-Redden, M. R.
2015-12-01
As new technologies are developed to utilize data more fully, and as shrinking budgets mean more needs to be done with less, well-documented and discoverable legacy data is vital for continued research and economic growth. Many governmental agencies are mandated to maintain scientific data, and the Geological Survey of Alabama (GSA) is no different. As part of the mandate to explore for, characterize, and report Alabama's mineral, energy, water, and biological resources for the betterment of Alabama's citizens, communities, and businesses, the GSA has increasingly been called upon to make our data (including samples) more accessible to stakeholders. The GSA has been involved in several data management, preservation, and rescue projects, including the National Geothermal Data System and the National Geological and Geophysical Data Preservation Program. GSA staff utilizes accepted standards for metadata, such as those found at the US Geoscience Information Network (USGIN). Through the use of semi-automated workflows, these standards can be applied to legacy data records. As demand for more detailed information on samples increases, especially so that a researcher can do a preliminary assessment prior to a site visit, it has become critical for the efficiency of the GSA to have better systems in place for sample tracking and data management. Thus, GSA is in the process of registering cores and related samples for International Geo Sample Numbers (IGSNs) through the System for Earth Sample Registration. IGSNs allow the GSA to use asset management software to better curate the physical samples and provide more accurate information to stakeholders. Working with other initiatives, such as EarthCube's iSamples project, will ensure that GSA continues to use best practices and standards for sample identification, documentation, citation, curation, and sharing.
77 FR 58707 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
... Gaming Commission 25 CFR Part 543 Minimum Internal Control Standards; Final Rule #0;#0;Federal Register... Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class II gaming...
77 FR 43196 - Minimum Internal Control Standards and Technical Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... NATIONAL INDIAN GAMING COMMISSION 25 CFR Parts 543 and 547 Minimum Internal Control Standards [email protected] . SUPPLEMENTARY INFORMATION: Part 543 addresses minimum internal control standards (MICS) for Class II gaming operations. The regulations require tribes to establish controls and implement...
2018-02-01
international proficiency testing sponsored by the Organisation for the Prohibition of Chemical Weapons (The Hague, Netherlands). Traditionally...separate batch of standards at each level for a total of six analyses at each calibration level. Concentrations of the tested calibration levels are...and ruthenium at each calibration level. 11 REFERENCES 1. General Requirements for the Competence of Testing and Calibration Laboratories
The Second International Standard for Penicillin*
Humphrey, J. H.; Mussett, M. V.; Perry, W. L. M.
1953-01-01
In 1950 the Department of Biological Standards, National Institute for Medical Research, London, was authorized by the WHO Expert Committee on Biological Standardization to prepare the Second International Standard for Penicillin. A single batch of specially recrystallized sodium penicillin G was obtained and 11 laboratories in seven different countries were requested to take part in its collaborative assay. 112 assays were carried out, of which 101 were done by cup-plate methods using either Staphylococcus aureus or Bacillus subtilis. The results were subjected to standard methods of analysis, on the basis of which the authors define the Second International Standard for Penicillin as containing 1,670 International Units (IU) per mg, with limits of error (P = 0.05) of 1,666-1,674 IU/mg. The International Unit is therefore redefined as the activity contained in 0.0005988 mg of the Second International Standard for Penicillin. PMID:13082387
Percy, Andrew J; Yang, Juncong; Chambers, Andrew G; Mohammed, Yassene; Miliotis, Tasso; Borchers, Christoph H
2016-01-01
Quantitative mass spectrometry (MS)-based approaches are emerging as a core technology for addressing health-related queries in systems biology and in the biomedical and clinical fields. In several 'omics disciplines (proteomics included), an approach centered on selected or multiple reaction monitoring (SRM or MRM)-MS with stable isotope-labeled standards (SIS), at the protein or peptide level, has emerged as the most precise technique for quantifying and screening putative analytes in biological samples. To enable the widespread use of MRM-based protein quantitation for disease biomarker assessment studies and its ultimate acceptance for clinical analysis, the technique must be standardized to facilitate precise and accurate protein quantitation. To that end, we have developed a number of kits for assessing method/platform performance, as well as for screening proposed candidate protein biomarkers in various human biofluids. Collectively, these kits utilize a bottom-up LC-MS methodology with SIS peptides as internal standards and quantify proteins using regression analysis of standard curves. This chapter details the methodology used to quantify 192 plasma proteins of high-to-moderate abundance (covers a 6 order of magnitude range from 31 mg/mL for albumin to 18 ng/mL for peroxidredoxin-2), and a 21-protein subset thereof. We also describe the application of this method to patient samples for biomarker discovery and verification studies. Additionally, we introduce our recently developed Qualis-SIS software, which is used to expedite the analysis and assessment of protein quantitation data in control and patient samples.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY... hazardous air pollutants for stationary reciprocating internal combustion engines and the standards of performance for stationary internal combustion engines. Subsequently, the EPA received three petitions for...
Quantification and characterization of Si in Pinus Insignis Dougl by TXRF
NASA Astrophysics Data System (ADS)
Navarro, Henry; Bennun, Leonardo; Marcó, Lué M.
2015-03-01
A simple quantification of silicon is described, in woods such as Pinus Insigne Dougl obtained from the 8th region of Bío-Bío, 37°15″ South-73°19″ West, Chile. The samples were prepared through fractional calcination, and the ashes were directly analyzed by total reflection X-ray fluorescence (TXRF) technique. The analysis of 16 samples that were calcined is presented. The samples were weighed on plastic reflectors in a microbalance with sensitivity of 0.1 µg. Later, the samples were irradiated in a TXRF PICOFOX spectrometer, for 350 and 700 s. To each sample, cobalt was added as an internal standard. Concentrations of silicon over the 1 % in each sample and the self-absorption effect on the quantification were observed, in masses higher than 100 μg.
Degradation of partially immersed glass: A new perspective
NASA Astrophysics Data System (ADS)
Chinnam, R. K.; Fossati, P. C. M.; Lee, W. E.
2018-05-01
The International Simple Glass (ISG) is a six-component borosilicate glass which was developed as a reference for international collaborative studies on high level nuclear waste encapsulation. Its corrosion behaviour is typically examined when it is immersed in a leaching solution, or when it is exposed to water vapour. In this study, an alternative situation is considered in which the glass is only partially immersed for 7 weeks at a temperature of 90 °C. In this case, half of the glass sample is directly in the solution itself, and the other half is in contact with a water film formed by condensation of water vapour that evaporated from the solution. This results in a different degradation behaviour compared to standard tests in which the material is fully immersed. In particular, whilst in standard tests the system reaches a steady state with a very low alteration rate thanks to the formation of a protective gel layer, in partially-immersed tests this steady state could not be reached because of the continuous alteration from the condensate water film. The constant input of ions from the emerged part of the sample caused a supersaturation of the solution, which resulted in early precipitation of secondary crystalline phases. This setup mimics storage conditions once small amounts of water have entered a glass waste form containing canister. It offers a more realistic outlook of corrosion mechanisms happening in such situations than standard fully-immersed corrosion tests.
Schwertschlag, U; Nakata, L M; Gal, J
1984-01-01
Several high-pressure liquid chromatography procedures for the determination of flucytosine in serum or plasma have appeared. Some of these suffer from significant disadvantages, and none was applicable in our routine clinical therapeutic-drug-monitoring laboratory. A new high-pressure liquid chromatography assay for flucytosine was therefore developed. A 100-microliter sample of plasma was treated with an aqueous 5-iodocytosine internal-standard solution, and the mixture was deproteinized with trichloroacetic acid. A portion of the protein-free supernatant was diluted with 0.1 M ammonium phosphate, and an aliquot of the resulting solution was injected into the high-pressure liquid chromatography system. Chromatography was performed on a strong-cation-exchange column with a mobile phase containing aqueous ammonium phosphate, phosphoric acid, methanol, and acetonitrile. Detection was at 254 nm. The assay was shown to be linear in the 10 to 200-micrograms/ml drug-concentration range. Forty other drugs were tested for potential interference with the assay, and none was found. For routine use, a single-point working standard containing 75 micrograms of flucytosine per ml was used, giving intraassay coefficients of variation at 50 and 150 micrograms/ml of 1.8 and 2.3% respectively, whereas the day-to-day coefficient of variation at 50 micrograms/ml was 10.0%. Advantages of the procedure include the small sample size, the use of a convenient and reliable internal standard, speed, and simplicity. The assay is highly suitable for routine clinical drug-analysis laboratories. PMID:6508261
An Evaluation of Unit and ½ Mass Correction Approaches as a ...
Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive on 66Zn. Currently, US EPA Method 200.8 does not address these as sources of false positives. Additionally, these M+2 false positives are typically enhanced if collision cell technology is utilized to reduce polyatomic interferences associated with ICP-MS detection. A preliminary evaluation indicates that instrumental tuning conditions can impact the observed M+2/M+1 ratio and in turn the false positives generated on Zn, As and Se. Both unit and ½ mass approaches will be evaluated to correct for these false positives relative to the benchmark concentrations estimates from a triple quadrupole ICP-MS using standard solutions. The impact of matrix on these M+2 corrections will be evaluated over multiple analysis days with a focus on evaluating internal standards that mirror the matrix induced shifts in the M+2 ion transmission. The goal of this evaluation is to move away from fixed M+2 corrective approaches and move towards sample specific approaches that mimic the sample matrix induced variability while attempting to address intra-day variability of the M+2 correction factors through the use of internal standards. Oral Presentation via webinar for EPA Laboratory Technical Informati
Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.
2009-01-01
The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8.35 (n = 206), and glufosinate 9.3 plus or minus 9.16 (n = 16). The analytical variation of the method, comparison of quantitation by isotope dilution and multipoint linear regressed standard curves, and method detection levels were evaluated by analyzing six sets of distilled-water, groundwater, and surface-water samples spiked in duplicate at 0.0, 0.05, 0.10 and 0.50 microgram per liter and analyzed on 6 different days during 1 month. The grand means of the normalized concentration percentage recovery for glyphosate, AMPA, and glufosinate among all three matrices and spiked concentrations ranged from 99 to 114 plus or minus 2 to 7 percent of the expected spiked concentration. The grand mean of the percentage difference between concentrations calculated by standard addition and linear regressed multipoint standard curves ranged from 8 to 15 plus or minus 2 to 9 percent for the three compounds. The method reporting levels calculated from all the 0.05- microgram per liter spiked samples were 0.02 microgram per liter for all three compounds. Compound stability experiments were conducted on 10 samples derivatized four times for periods between 136 to 269 days. The glyphosate and AMPA concentrations remained relatively constant in samples held up to 136 days before derivatization. The half life of glyphosate varied from 169 to 223 days in the underivatized samples. Derivatized samples were analyzed the day after derivitization, and again 54 and 64 days after derivatization. The derivatized samples analyzed at days 52 and 64 were within 20 percent of the concentrations of the derivatized samples analyzed the day after derivatization.
Baya Botti, A; Pérez-Cueto, F J A; Vasquez Monllor, P A; Kolsteren, P W
2010-01-01
Since no growth standards for adolescents exist and a single reference applicable everywhere is still in debate, it is recognized that the best reference should be derived from the growth pattern of the healthy population that will use it. In 2007 a study developed references for body mass index for 12th to 18th y Bolivian school adolescent (BAP. To compare nutritional status outcomes applying BMI references from the BAP, the Center for Disease Control and Prevention CDC 2000, the International Task Force (IOTF), and the 2007 WHO, to determine appropriateness of use in Bolivian adolescents. References were applied in 3306 adolescents, 45.0% male, 55% female, 12th to 18th y selected from a nationally representative sample. Main findings reveal that the CDC and the 2007 WHO underestimate underweight (p<0.001) and the three international references overestimate overweight (p<0.001) with variation between ages and gender. Bolivian health providers are advised to replace CDC, OITF and 2007 WHO references for the use of BAP in Bolivia which reflects its healthy adolescent population growth pattern. International references may lead to incorrect conclusions when applied on Bolivian adolescents. They could deflect efforts from population which need prompt intervention and mislead treatments and budget to unnecessary ones. We recommend validation of international references where appropriate until a standard is released.
González-Sálamo, Javier; González-Curbelo, Miguel Ángel; Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel Ángel
2018-06-01
A new hollow fiber liquid-phase microextraction (HF-LPME) method has been developed for the extraction of a group of phthalic acid esters (PAEs) of interest from different water samples prior to gas chromatography tandem mass spectrometry analysis. HF-LPME was carried out using 1-octanol as extraction solvent followed by a back extraction step with cyclohexane. The different parameters that affect HF-LPME such as sample pH, ionic strength, extraction time, stirring rate, extraction temperature and back extraction conditions were investigated. The optimized conditions involved the extraction of 10 mL of sample without pH adjustment or addition of salt during 75 min under a stirring of 850 rpm at 60 °C and subsequent desorption with 200 μL of cyclohexane for 10 min in an ultrasonic bath. The method was validated in terms of calibration and recovery studies using dibutyl phthalate-d 4 as internal standard. The developed procedure gave satisfactory recovery (74-120%) and relative standard deviation values (<20%) for the studied PAEs in mineral, tap, pond and waste water samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
The International Standard for Anti-Brucella abortus Serum
Stableforth, A. W.
1954-01-01
In field trials on the eradication of brucellosis from dairy herds in Great Britain, which began in 1933, a serum standard of reference was used for the examination of agglutinating suspensions prepared in different laboratories. In 1937, the Office International des Epizooties (OIE) adopted this standard and made recommendations for its use internationally. These recommendations were revised by OIE in 1948, by the Third Inter-American Congress on Brucellosis and by the Joint FAO/WHO Expert Panel on Brucellosis in 1950, and again by the latter body in 1952. A new batch equivalent in potency to the original standard was established by the WHO Expert Committee on Biological Standardization in 1952 as the International Standard for Anti-Brucella abortus Serum. The International Standard, or a national standard of equivalent potency, ensures comparability of the titres obtained in different countries by different methods, and the results of such comparisons can be expressed in a simple manner by describing the titres in terms of International Units of Brucella antibody. PMID:13199656
The French initiative for scientific cores virtual curating : a user-oriented integrated approach
NASA Astrophysics Data System (ADS)
Pignol, Cécile; Godinho, Elodie; Galabertier, Bruno; Caillo, Arnaud; Bernardet, Karim; Augustin, Laurent; Crouzet, Christian; Billy, Isabelle; Teste, Gregory; Moreno, Eva; Tosello, Vanessa; Crosta, Xavier; Chappellaz, Jérome; Calzas, Michel; Rousseau, Denis-Didier; Arnaud, Fabien
2016-04-01
Managing scientific data is probably one the most challenging issue in modern science. The question is made even more sensitive with the need of preserving and managing high value fragile geological sam-ples: cores. Large international scientific programs, such as IODP or ICDP are leading an intense effort to solve this problem and propose detailed high standard work- and dataflows thorough core handling and curating. However most results derived from rather small-scale research programs in which data and sample management is generally managed only locally - when it is … The national excellence equipment program (Equipex) CLIMCOR aims at developing French facilities for coring and drilling investigations. It concerns indiscriminately ice, marine and continental samples. As part of this initiative, we initiated a reflexion about core curating and associated coring-data management. The aim of the project is to conserve all metadata from fieldwork in an integrated cyber-environment which will evolve toward laboratory-acquired data storage in a near future. In that aim, our demarche was conducted through an close relationship with field operators as well laboratory core curators in order to propose user-oriented solutions. The national core curating initiative currently proposes a single web portal in which all scientifics teams can store their field data. For legacy samples, this will requires the establishment of a dedicated core lists with associated metadata. For forthcoming samples, we propose a mobile application, under Android environment to capture technical and scientific metadata on the field. This application is linked with a unique coring tools library and is adapted to most coring devices (gravity, drilling, percussion, etc...) including multiple sections and holes coring operations. Those field data can be uploaded automatically to the national portal, but also referenced through international standards or persistent identifiers (IGSN, ORCID and INSPIRE) and displayed in international portals (currently, NOAA's IMLGS). In this paper, we present the architecture of the integrated system, future perspectives and the approach we adopted to reach our goals. We will also present in front of our poster, one of the three mobile applications, dedicated more particularly to the operations of continental drillings.
25 CFR 543.17 - What are the minimum internal control standards for drop and count?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...
25 CFR 543.15 - What are the minimum internal control standards for lines of credit?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for lines of credit? 543.15 Section 543.15 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.15 What are the minimum internal control standards for lines of credi...
25 CFR 543.9 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for pull tabs? 543.9 Section 543.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.9 What are the minimum internal control standards for pull tabs? (a)...
25 CFR 543.13 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 543.13 Section 543.13 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.13 What are the minimum internal control standards fo...
25 CFR 543.9 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for pull tabs? 543.9 Section 543.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.9 What are the minimum internal control standards for pull tabs? (a)...
25 CFR 543.15 - What are the minimum internal control standards for lines of credit?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for lines of credit? 543.15 Section 543.15 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.15 What are the minimum internal control standards for lines of credi...
25 CFR 543.17 - What are the minimum internal control standards for drop and count?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...
25 CFR 543.13 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for complimentary services or items? 543.13 Section 543.13 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.13 What are the minimum internal control standards fo...
Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet
2016-06-01
We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the inclusion of nursing-related standard operating procedures in certification/accreditation standards. © 2016 International Council of Nurses.
Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V
2014-01-01
The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.
International Space Station (ISS) 3D Printer Performance and Material Characterization Methodology
NASA Technical Reports Server (NTRS)
Bean, Q. A.; Cooper, K. G.; Edmunson, J. E.; Johnston, M. M.; Werkheiser, M. J.
2015-01-01
In order for human exploration of the Solar System to be sustainable, manufacturing of necessary items on-demand in space or on planetary surfaces will be a requirement. As a first step towards this goal, the 3D Printing In Zero-G (3D Print) technology demonstration made the first items fabricated in space on the International Space Station. From those items, and comparable prints made on the ground, information about the microgravity effects on the printing process can be determined. Lessons learned from this technology demonstration will be applicable to other in-space manufacturing technologies, and may affect the terrestrial manufacturing industry as well. The flight samples were received at the George C. Marshall Space Flight Center on 6 April 2015. These samples will undergo a series of tests designed to not only thoroughly characterize the samples, but to identify microgravity effects manifested during printing by comparing their results to those of samples printed on the ground. Samples will be visually inspected, photographed, scanned with structured light, and analyzed with scanning electron microscopy. Selected samples will be analyzed with computed tomography; some will be assessed using ASTM standard tests. These tests will provide the information required to determine the effects of microgravity on 3D printing in microgravity.
Food Insecurity and Mental Disorders in a National Sample of U.S. Adolescents
McLaughlin, Katie A.; Green, Jennifer Greif; Alegría, Margarita; Costello, E. Jane; Gruber, Michael J.; Sampson, Nancy A.; Kessler, Ronald C.
2013-01-01
Objective To examine whether food insecurity is associated with past-year DSM-IV mental disorders after controlling for standard indicators of family socioeconomic status (SES) in a U.S. national sample of adolescents. Method Data were drawn from 6,483 adolescent–parent pairs who participated in the National Comorbidity Survey Replication Adolescent Supplement, a national survey of adolescents 13 to 17 years old. Frequency and severity of food insecurity were assessed with questions based on the U.S. Department of Agriculture’s Food Security Scale (standardized to a mean of 0, variance of 1). DSM-IV mental disorders were assessed with the World Health Organization Composite International Diagnostic Interview. Associations of food insecurity with DSM-IV/Composite International Diagnostic Interview diagnoses were estimated with logistic regression models controlling for family SES (parental education, household income, relative deprivation, community-level inequality, and subjective social status). Results Food insecurity was highest in adolescents with the lowest SES. Controlling simultaneously for other aspects of SES, standardized food insecurity was associated with an increased odds of past-year mood, anxiety, behavior, and substance disorders. A 1 standard deviation increase in food insecurity was associated with a 14%increase in the odds of past-year mental disorder, even after controlling for extreme poverty. The association between food insecurity and mood disorders was strongest in adolescents living in families with a low household income and high relative deprivation. Conclusions Food insecurity is associated with a wide range of adolescent mental disorders independently of other aspects of SES. Expansion of social programs aimed at decreasing family economic strain might be one useful policy approach for improving youth mental health. PMID:23200286
Review of research designs and statistical methods employed in dental postgraduate dissertations.
Shirahatti, Ravi V; Hegde-Shetiya, Sahana
2015-01-01
There is a need to evaluate the quality of postgraduate dissertations of dentistry submitted to university in the light of the international standards of reporting. We conducted the review with an objective to document the use of sampling methods, measurement standardization, blinding, methods to eliminate bias, appropriate use of statistical tests, appropriate use of data presentation in postgraduate dental research and suggest and recommend modifications. The public access database of the dissertations from Rajiv Gandhi University of Health Sciences was reviewed. Three hundred and thirty-three eligible dissertations underwent preliminary evaluation followed by detailed evaluation of 10% of randomly selected dissertations. The dissertations were assessed based on international reporting guidelines such as strengthening the reporting of observational studies in epidemiology (STROBE), consolidated standards of reporting trials (CONSORT), and other scholarly resources. The data were compiled using MS Excel and SPSS 10.0. Numbers and percentages were used for describing the data. The "in vitro" studies were the most common type of research (39%), followed by observational (32%) and experimental studies (29%). The disciplines conservative dentistry (92%) and prosthodontics (75%) reported high numbers of in vitro research. Disciplines oral surgery (80%) and periodontics (67%) had conducted experimental studies as a major share of their research. Lacunae in the studies included observational studies not following random sampling (70%), experimental studies not following random allocation (75%), not mentioning about blinding, confounding variables and calibrations in measurements, misrepresenting the data by inappropriate data presentation, errors in reporting probability values and not reporting confidence intervals. Few studies showed grossly inappropriate choice of statistical tests and many studies needed additional tests. Overall observations indicated the need to comply with standard guidelines of reporting research.
Food insecurity and mental disorders in a national sample of U.S. adolescents.
McLaughlin, Katie A; Green, Jennifer Greif; Alegría, Margarita; Jane Costello, E; Gruber, Michael J; Sampson, Nancy A; Kessler, Ronald C
2012-12-01
To examine whether food insecurity is associated with past-year DSM-IV mental disorders after controlling for standard indicators of family socioeconomic status (SES) in a U.S. national sample of adolescents. Data were drawn from 6,483 adolescent-parent pairs who participated in the National Comorbidity Survey Replication Adolescent Supplement, a national survey of adolescents 13 to 17 years old. Frequency and severity of food insecurity were assessed with questions based on the U.S. Department of Agriculture's Food Security Scale (standardized to a mean of 0, variance of 1). DSM-IV mental disorders were assessed with the World Health Organization Composite International Diagnostic Interview. Associations of food insecurity with DSM-IV/Composite International Diagnostic Interview diagnoses were estimated with logistic regression models controlling for family SES (parental education, household income, relative deprivation, community-level inequality, and subjective social status). Food insecurity was highest in adolescents with the lowest SES. Controlling simultaneously for other aspects of SES, standardized food insecurity was associated with an increased odds of past-year mood, anxiety, behavior, and substance disorders. A 1 standard deviation increase in food insecurity was associated with a 14% increase in the odds of past-year mental disorder, even after controlling for extreme poverty. The association between food insecurity and mood disorders was strongest in adolescents living in families with a low household income and high relative deprivation. Food insecurity is associated with a wide range of adolescent mental disorders independently of other aspects of SES. Expansion of social programs aimed at decreasing family economic strain might be one useful policy approach for improving youth mental health. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.
Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.
2014-01-01
Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099
Hartleif, Steffen; Göhring, Katharina; Goelz, Rangmar; Jahn, Gerhard; Hamprecht, Klaus
2016-11-01
For cytomegalovirus screening of breastfeeding mothers of preterm infants under risk, we present a rapid, quantitative real-time PCR protocol using the hybridization format of the viral gB target region. For quantification, we used an external gB fragment cloned into a vector system. For standardization, we created an internal control-plasmid by site-directed mutagenesis with an exchange of 9 nucleotides. Spiked with internal control, patient wildtype amplicons could be discriminated from internal controls by hybridization probes using two-channel fluorescence detection. Potential bias of formerly reported false nucleotide sequence data of gB-hybridization probes was excluded. Using this approach, we could demonstrate excellent analytical performance and high reproducibility of HCMV detection during lactation. This assay shows very good correlation with a commercial quantitative HCMV DNA PCR and may help to identify rapidly HCMV shedding mothers of very low birth weight preterm infants to prevent HCMV transmission. On the other hand, negative DNA amplification results allow feeding of milk samples of seropositive mothers to their preterm infants under risk (<30 weeks of gestational age, <1000g birth weight) during the onset and late stage of HCMV shedding during lactation. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Utschick, C.; Skoulatos, M.; Schneidewind, A.; Böni, P.
2016-11-01
The cold-neutron triple-axis spectrometer PANDA at the neutron source FRM II has been serving an international user community studying condensed matter physics problems. We report on a new setup, improving the signal-to-noise ratio for small samples and pressure cell setups. Analytical and numerical Monte Carlo methods are used for the optimization of elliptic and parabolic focusing guides. They are placed between the monochromator and sample positions, and the flux at the sample is compared to the one achieved by standard monochromator focusing techniques. A 25 times smaller spot size is achieved, associated with a factor of 2 increased intensity, within the same divergence limits, ± 2 ° . This optional neutron focusing guide shall establish a top-class spectrometer for studying novel exotic properties of matter in combination with more stringent sample environment conditions such as extreme pressures associated with small sample sizes.
Tagliaro, F; Manetto, G; Bellini, S; Scarcella, D; Smith, F P; Marigo, M
1998-01-01
The importance of the chiral analysis of amphetamine-related substances in both clandestine preparations and biological samples is widely recognized. For this purpose, capillary electrophoresis was successfully applied by several authors, but only few reports concerned ring-substituted amphetamines, which represent the main components of "ecstasy", a widely abused "recreational" substance. In the present work, the simultaneous chiral analysis of ephedrine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3-4-methylenedioxyamphetamine (MDA) and 3,4-methalenedioxyethylamphetamine (MDE) is reported, by using capillary electrophoresis with native beta-cyclodextrin (15 mM) as the chiral selector. After preliminary tests at different pH values (phosphate buffer 100 mM, pH 2.5-9.0) and with bare or coated fused-silica capillaries, the optimized conditions were: pH 2.5 phosphate, uncoated capillary (45 cm x 50 microm inner diameter), potential 10 kV. Detection was either by fixed wavelength (200 nm) or multiwavelength (190-400 nm) UV absorbance. Under these conditions, good resolution was obtained for all the analytes, with excellent chiral selectivity and efficiency. The sensitivity for the individual enantiomers was better than 0.2 microg/mL, analytical precision was characterized by relative standard deviation values < 0.8% (< or = 0.15% with internal standardization) for migration times intra-day and < 2.0% (< or = 0.54% with internal standardization) day-to-day; linearity, in the range 0.156-40 microg/mL, and accuracy were also satisfactory. After a simple liquid-liquid extraction, urine samples could be analyzed with a sensitivity well below the recommended NIDA cut-off of 500 ng/mL. For hair samples, it was necessary to increase the sensitivity by applying a field-amplified sample stacking procedure, which allowed the chiral determination of MDA, MDMA and MDE at concentrations occurring in real samples from ecstasy users, with the possibility of recording UV spectra of the peaks.
NASA Astrophysics Data System (ADS)
Pasztor, G.; Bruzzone, P.
2004-06-01
The dc performance of a recently produced internal tin route Nb3Sn strand with enhanced specification is studied extensively and compared with predecessor wires manufactured by the suppliers for the ITER Model Coils in 1996. The wire has been selected for use in a full size, developmental cable-in-conduit conductor sample, which is being tested in the SULTAN Test Facility. The critical current, Ic, and the index of the current/voltage characteristic, n, are measured over a broad range of field and temperature, using ITER standard sample holders, made of TiAlV grooved cylinders. The behavior of Ic versus applied tensile strain is also investigated at 4.2 K and 12 T, on straight specimens. Scaling law parameters are drawn from the fit of the experimental results. The implications of the test results to the design of the fusion conductors are discussed.
Volker, Martin A.; Dua, Elissa H.; Lopata, Christopher; Thomeer, Marcus L.; Toomey, Jennifer A.; Smerbeck, Audrey M.; Rodgers, Jonathan D.; Popkin, Joshua R.; Nelson, Andrew T.; Lee, Gloria K.
2016-01-01
The Gilliam Autism Rating Scale-Second Edition (GARS-2) is a widely used screening instrument that assists in the identification and diagnosis of autism. The purpose of this study was to examine the factor structure, internal consistency, and screening sensitivity of the GARS-2 using ratings from special education teaching staff for a sample of 240 individuals with autism or other significant developmental disabilities. Exploratory factor analysis yielded a correlated three-factor solution similar to that found in 2005 by Lecavalier for the original GARS. Though the three factors appeared to be reasonably consistent with the intended constructs of the three GARS-2 subscales, the analysis indicated that more than a third of the GARS-2 items were assigned to the wrong subscale. Internal consistency estimates met or exceeded standards for screening and were generally higher than those in previous studies. Screening sensitivity was .65 and specificity was .81 for the Autism Index using a cut score of 85. Based on these findings, recommendations are made for instrument revision. PMID:26981279
Development of a framework of quality assurance practices for a radon passive dosemeter service.
D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M
2010-06-01
Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.
Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya
2013-01-01
Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607
Results from the (U-Th)/He dating systems in Japan Atomic Energy Agency
NASA Astrophysics Data System (ADS)
Yamada, K.; Hanamuro, T.; Tagami, T.; Yamada, R.; Umeda, K.
2007-12-01
Japan Atomic Energy Agency (JAEA) has jointly set up the lab of the (U-Th)/He dating in cooperation with Kyoto University and National Research Institute for Earth Science and Disaster Prevention. We use the MM5400 rare gas mass spectrometer and the SPQ9000 ICP quadrupole mass spectrometer, belonging to JAEA, and built a new vacuum heater using infrared laser to extract helium. HF decomposes zircon after the alkali-fusion method using XRF bead sampler and LiBO3 in the preparation of ICP solution. Helium is quantified using sensitivity method. Uranium and thorium are using standard addition method. Quantifications of uranium-238 and thorium-232 are only need for parent isotopes to date samples because they are expected that the state of secular equilibrium becomes established and samarium does not compose the samples. At the present stage, we calibrate our systems by dating some standards, such as zircon from the Fish Canyon Tuff and apatite from the Durango, those are the international age standard, and apatite and zircon from the Tanzawa Tonalite Complex, that was dated in Yamada's PhD thesis, as a working standard. We report the results and detailed views of the dating systems.
Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria
2011-09-01
Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected <40 cp/mL" in the standard assay. The "modified" and "ultrasensitive" assays are precise and accurate, and easily adoptable in routine diagnostic laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.
This standard operating procedure describes the method used for preparing internal standard, surrogate recovery standard and calibration standard solutions for neutral analytes used for gas chromatography/mass spectrometry analysis.
Batta, N; Pilli, N R; Derangula, V R; Vurimindi, H B; Damaramadugu, R; Yejella, R P
2015-03-01
The authors proposed a simple, rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay method for the simultaneous determination of saxagliptin and its active metabolite 5-hydroxy saxagliptin in human plasma. The developed method was fully validated as per the US FDA guidelines. The method utilized stable labeled isotopes saxagliptin-15 N d2 (IS1) and 5-hydroxy saxagliptin-15 N-d2 (IS2) as internal standards for the quantification of saxagliptin and 5-hydroxy saxagliptin, respectively. Analytes and the internal standards were extracted from human plasma by a single step solid-phase extraction technique without drying, evaporation and reconstitution steps. The optimized mobile phase was composed of 0.1% acetic acid in 5 mM ammonium acetate and acetonitrile (30:70, v/v) and delivered at a flow rate of 0.85 mL/min. The method exhibits the linear calibration range of 0.05-100 ng/mL for both the analytes. The precision and accuracy results for both the analytes were well within the acceptance limits. The different stability experiments conducted in aqueous samples and in matrix samples are meeting the acceptance criteria. The chromatographic run time was set at 1.8 min; hence more than 400 samples can be analyzed in a single day. © Georg Thieme Verlag KG Stuttgart · New York.
European validation of Real-Time PCR method for detection of Salmonella spp. in pork meat.
Delibato, Elisabetta; Rodriguez-Lazaro, David; Gianfranceschi, Monica; De Cesare, Alessandra; Comin, Damiano; Gattuso, Antonietta; Hernandez, Marta; Sonnessa, Michele; Pasquali, Frédérique; Sreter-Lancz, Zuzsanna; Saiz-Abajo, María-José; Pérez-De-Juan, Javier; Butrón, Javier; Prukner-Radovcic, Estella; Horvatek Tomic, Danijela; Johannessen, Gro S; Jakočiūnė, Džiuginta; Olsen, John E; Chemaly, Marianne; Le Gall, Francoise; González-García, Patricia; Lettini, Antonia Anna; Lukac, Maja; Quesne, Segolénè; Zampieron, Claudia; De Santis, Paola; Lovari, Sarah; Bertasi, Barbara; Pavoni, Enrico; Proroga, Yolande T R; Capuano, Federico; Manfreda, Gerardo; De Medici, Dario
2014-08-01
The classical microbiological method for detection of Salmonella spp. requires more than five days for final confirmation, and consequently there is a need for an alternative methodology for detection of this pathogen particularly in those food categories with a short shelf-life. This study presents an international (at European level) ISO 16140-based validation study of a non-proprietary Real-Time PCR-based method that can generate final results the day following sample analysis. It is based on an ISO compatible enrichment coupled to an easy and inexpensive DNA extraction and a consolidated Real-Time PCR assay. Thirteen laboratories from seven European Countries participated to this trial, and pork meat was selected as food model. The limit of detection observed was down to 10 CFU per 25 g of sample, showing excellent concordance and accordance values between samples and laboratories (100%). In addition, excellent values were obtained for relative accuracy, specificity and sensitivity (100%) when the results obtained for the Real-Time PCR-based methods were compared to those of the ISO 6579:2002 standard method. The results of this international trial demonstrate that the evaluated Real-Time PCR-based method represents an excellent alternative to the ISO standard. In fact, it shows an equal and solid performance as well as it reduces dramatically the extent of the analytical process, and can be easily implemented routinely by the Competent Authorities and Food Industry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.
Cocci, Andrea; Zuppi, Cecilia; Persichilli, Silvia
2013-01-01
Objective. 25-hydroxyvitamin D2/D3 (25-OHD2/D3) determination is a reliable biomarker for vitamin D status. Liquid chromatography-tandem mass spectrometry was recently proposed as a reference method for vitamin D status evaluation. The aim of this work is to compare two commercial kits (Chromsystems and PerkinElmer) for 25-OHD2/D3 determination by our entry level LC-MS/MS. Design and Methods. Chromsystems kit adds an online trap column to an HPLC column and provides atmospheric pressure chemical ionization, isotopically labeled internal standard, and 4 calibrator points. PerkinElmer kit uses a solvent extraction and protein precipitation method. This kit can be used with or without derivatization with, respectively, electrospray and atmospheric pressure chemical ionization. For each analyte, there are isotopically labeled internal standards and 7 deuterated calibrator points. Results. Performance characteristics are acceptable for both methods. Mean bias between methods calculated on 70 samples was 1.9 ng/mL. Linear regression analysis gave an R 2 of 0.94. 25-OHD2 is detectable only with PerkinElmer kit in derivatized assay option. Conclusion. Both methods are suitable for routine. Chromsystems kit minimizes manual sample preparation, requiring only protein precipitation, but, with our system, 25-OHD2 is not detectable. PerkinElmer kit without derivatization does not guarantee acceptable performance with our LC-MS/MS system, as sample is not purified online. Derivatization provides sufficient sensitivity for 25-OHD2 detection. PMID:23555079
Lack of transferability between two automated immunoassays for serum IGF-I measurement.
Gomez-Gomez, Carolina; Iglesias, Eva M; Barallat, Jaume; Moreno, Fernando; Biosca, Carme; Pastor, Mari-Cruz; Granada, Maria-Luisa
2014-01-01
IGF-I is a clinically relevant protein in the diagnosis and monitoring of treatment of growth disor- ders. The Growth Hormone Research Society and the International IGF Research Society have encouraged the adoption of a universal calibration for immunoassays to improve standardization of IGF-I measurements, but currently commercial assays are calibrated either against the old WHO IRR 87/518 or the new WHO 02/254. We compared two IGF-I immunochemiluminescent assays: IMMULITE® 2000 (Siemens) and LIAISON® (DiaSorin), which differ in their standardization, and verified their precision according to quality specifications based on biological variation and their linear range. 62 patient serum samples were analyzed for both assays and compared according to standards of the Clinical and Laboratory Standards Institute (CLSI), EP9-A2-IR. Precision was verified according to CLSI EP15- A2. Optimal coefficient of variation (CVo) and desirable coefficient of variation (CVd) for IGF-I assays were calculated as quality specifications based on the biological variability, in order to assess if the interassay analytical CV (CVa1) in the two methods were appropriate. Two dilution series using the 1st WHO International Standard (WHO IS) for IGF-I 02/254 were used to verify and compare the linearity range. The regression analysis showed constant and proportional differences for serum samples (slope b = 0.8115 (CI 95% CI; 0.7575-0.8556); intercept a = 33.6873 (95% CI: 23.3613-44.0133) between assays and similar pro- portional differences for WHO IS 02/254 standard dilutions series (slope b = 0.8024 (CI 95% CI; 0.7560-0.8616); intercept a = 6.9623 (95% CI: -2.0819-18.4383) between assays. Within-laboratory coefficients of variation for low and high levels were 2.82% and 3.80% for IMMULITE® 2000 and 3.58% and 2.14% for LIAISON®, respecttively. IGF-I concentrations measured by both assays are not transferable. The results emphasize the need to express IGF-I concentrations in standard deviation score (SDS) according to a matched normal population of the same age and gender. Within-laboratory precision in both methods met quality specifications derived from biological variation.
Gao, Jie; Liu, Qing; Han, Feng; Miao, Hong; Zhao, Yunfeng; Wu, Yongning
2014-05-01
To establish a method for the determination of fatty acid esters of 3-monochloropropane-1, 2-diol (3-MCPD) and 2-monochloropropane-1, 3-diol (2-MCPD) in diet samples by gas chromatography-mass spectrometry (GC-MS) with solid-supported liquid-liquid extraction (SLE). Diet samples were ultrasonically extracted by hexane, followed by ester cleavage reaction with sodium methylate in methanol, and then purified by solid-supported liquid-liquid extraction. (SLE) using diatomaceous earth as the sorbent. After derivatization with heptafluorobutyrylimidazole, the analytes were detected by GC-MS and quantified by the deuterated internal standards. The limits of detection (LODs) of 3-MCPD esters and 2-MCPD esters in different diet samples were 0.002 - 0.005 mg/kg and 0.002 - 0.006 mg/kg. The average recoveries of 3-MCPD esters and 2-MCPD esters at the spiking levels of 0.05 and 0.1 mg/kg in the diet samples were in the range of 65.9% - 104.2% and 75.4% - 118.0%, respectively, with the relative standard deviations in the range of 2.2% - 14.2% and 0.8% - .13.9%. The method is simple, accurate and rugged for the determination of fatty acid esters of 3-MCPD and 2-MCPD in diet samples.
International Standardization of Bed Rest Standard Measures
NASA Technical Reports Server (NTRS)
Cromwell, Ronita L.
2010-01-01
This slide presentation gives an overview of the standardization of bed rest measures. The International Countermeasures Working Group attempted to define and agree internationally on standard measurements for spaceflight based bed rest studies. The group identified the experts amongst several stakeholder agencys. It included information on exercise, muscle, neurological, psychological, bone and cardiovascular measures.
ERIC Educational Resources Information Center
Burns, Matthew K.; Boice, Christina H.
2009-01-01
The current study replicated MacQuarrie, Tucker, Burns, and Hartman (2002) with a sample of 20 students who had been identified with a disability and had an IQ score that was between 1 and 3 standard deviations below the normative mean. Each student was taught 27 words from the Esperanto International Language with the following conditions: (a)…
Monakhova, Yulia B; Diehl, Bernd W K; Do, Tung X; Schulze, Margit; Witzleben, Steffen
2018-02-05
Apart from the characterization of impurities, the full characterization of heparin and low molecular weight heparin (LMWH) also requires the determination of average molecular weight, which is closely related to the pharmaceutical properties of anticoagulant drugs. To determine average molecular weight of these animal-derived polymer products, partial least squares regression (PLS) was utilized for modelling of diffused-ordered spectroscopy NMR data (DOSY) of a representative set of heparin (n=32) and LMWH (n=30) samples. The same sets of samples were measured by gel permeation chromatography (GPC) to obtain reference data. The application of PLS to the data led to calibration models with root mean square error of prediction of 498Da and 179Da for heparin and LMWH, respectively. The average coefficients of variation (CVs) did not exceed 2.1% excluding sample preparation (by successive measuring one solution, n=5) and 2.5% including sample preparation (by preparing and analyzing separate samples, n=5). An advantage of the method is that the sample after standard 1D NMR characterization can be used for the molecular weight determination without further manipulation. The accuracy of multivariate models is better than the previous results for other matrices employing internal standards. Therefore, DOSY experiment is recommended to be employed for the calculation of molecular weight of heparin products as a complementary measurement to standard 1D NMR quality control. The method can be easily transferred to other matrices as well. Copyright © 2017 Elsevier B.V. All rights reserved.
Sharaf, Maged H M; Stiff, Dwight D
2004-06-29
A method for the quantitation of guaifenesin in human serum has been developed and validated. The procedure involves liquid-liquid extraction of the serum sample in the presence of mephenesin as an internal standard, followed by derivatization and analysis using capillary gas chromatography (GC) and electron capture detection (ECD). Different solvents were tested for extraction of guaifenesin from serum. n-Hexane/dichloromethane (1:1, v/v) gave the highest recovery and the lowest background and was chosen as the extraction solvent. After extraction, the residue of guaifenesin was derivatized at 60 degrees C for 30 min, with trifluoroacetic acid anhydride (TFAA) in toluene in the presence of pyridine. Excess trifluoroacetic acid anhydride was removed using dilute solution of ammonium hydroxide. The method proved to be linear over the range of 25.0-1000 ng/ml. Recovery of guaifenesin from spiked samples was consistent, averaging 75.5% at 50.0 ng/ml with a range of 72.0-80.0% (N = 8 determinations) and averaging 78% at 800 ng/ml with a range of 76.0-81.0% (N = 8 determinations). The internal standard recovery was also consistent averaging 72.8% with a range of 67.0-76.0% (N = 16 determinations). Copyright 2004 Elsevier B.V.
Impact of external haematology proficiency testing programme on quality of laboratories.
Saxena, Renu; Katoch, S C; Srinivas, Upendra; Rao, Seema; Anand, Hema
2007-11-01
A reliable and reproducible report from a laboratory needs internal quality control within the laboratory and participation in external proficiency testing programmes (EPTP). This study conducted at the Department of Haematology, All India Institute of Medical Sciences (AIIMS), New Delhi, which has been conducting an EPTP since 1992, was undertaken to assess the efficacy of this programme in improving the performance of participating laboratories in reporting test samples sent for Hb, total leucocyte count (TLC), reticulocyte count and assessment of peripheral blood smear (PBS). The samples were prepared in our laboratory according to the International Standards Organization (ISO) guidelines. The performance of individual laboratories was assessed using robust Z score, which is an indicator of acceptability of the test result. An improvement in the overall percentage of laboratories with acceptable reports was seen during the study period. It has increased from 38,40,40 per cent in 1992 to 85, 90,94.7 per cent in 2006 for Hb, TLC, reticulocyte count, respectively. However, the results for peripheral smear assessment improved only marginally. The external haematology proficiency testing programme run by our department for Hb, TLC, reticulocyte count, and peripheral blood smear assessment, has helped in improving the reporting standards of these parameters in Indian laboratories.
Duan, X; Ning, M
2015-01-01
Preparation and in vitro/in vivo evaluation of mifepristone intravaginal ring formulations were investigated. In the present study, it is reported that a mifepristone intravaginal ring of reservoir design comprising of a mifepristone silicone elastomer core enclosed in a silicone layer. During the preparation of intravaginal ring solid dispersion method was employed which improved the release rate of drug from the intravaginal ring. In vitro release studies performed under sink conditions and the released drug amounts were estimated using UV spectrometry at 310 nm. In addition, the in vivo release profile of in-house devices was evaluated in female New Zealand white rabbits. The rabbit plasma samples were processed and analyzed using a validated HPLC-MS method. Norgestrel was used as internal standard, and plasma samples contained mifepristone and internal standard were deproteinized, and then subjected to HPLC-MS analysis under condition of electrospray ionization in the selected ion monitoring mode. The drug release from intravaginal ring made in house was constant for 21 days in rabbits, which suggested the mifepristone intravaginal ring release system would be useful in clinical practice in the future. The result indicated the in vitro/in vivo correlation is perfect, which explained in vitro release analysis method developed was feasible.
Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao
2017-08-28
Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.
The International Standard for Aureomycin
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1953-01-01
In 1950, the Department of Biological Standards, National Institute for Medical Research, London, was authorized by the WHO Expert Committee on Biological Standardization to proceed with the establishment of an International Standard for Aureomycin. A 100-g batch of aureomycin was obtained and was compared with the Standard Preparation of Aureomycin of the United States Food and Drug Administration (FDA) in a collaborative assay in which six laboratories in five countries participated. In all, 30 assays were carried out; 26 of these were done by biological methods, using Sarcina lutea, Bacillus pumilus, Staphylococcus aureus, or Bacillus cereus, and the remaining four by physicochemical methods. The results were subjected to standard methods of analysis, and the overall weighted mean potency (calculated from the biological assays only) was 1.0139, with limits of error of 99.5% to 100.5%. Since the International Standard is 1.39% more potent than the FDA Standard Preparation, it is probable that the latter contains a small amount of inert material; it is also possible that the International Standard itself is not 100% pure. For most practical purposes, however, both preparations may be regarded as substantially pure, and it is considered that to alter the present practice of quoting aureomycin dosage in metric units of weight would be inadvisable. Nevertheless, since the International Standard may not be a pure substance, a unit notation—for use where required in bioassays—is desirable, and the International Unit of Aureomycin has therefore been defined as the activity contained in one microgram of the International Standard. PMID:13141137
Dron, Julien; Linke, Robert; Rosenberg, Erwin; Schreiner, Manfred
2004-08-20
A procedure for the determination of fatty acids (FA) and glycerol in oils has been developed. The method includes a derivatization step of the FAs into their methyl esters or a transesterification of the triacylglycerols with trimethylsulfonium hydroxide (TMSH), respectively. The analysis is carried out by gas chromatography with parallel flame ionization and mass spectrometric detection. The parameters involved in the transesterification reaction were optimized. Only the stoichiometric ratio of TMSH:total FA amount showed a significant influence on the reaction yield. Relative standard deviations for 10 replicates were below 3% for all FAs studied and their linearity range was 0.5-50 mmol/L, when using heptadecanoic acid as an internal standard. The final procedure was rapid and required little sample handling. It was then tested on fresh oil samples and presented satisfying results, in agreement with previous works.
Determination of emamectin benzoate in medicated fish feed.
Farer, L J; Hayes, J; Rosen, J; Knight, P
1999-01-01
A method was developed to quantitate emamectin benzoate in fish feed at levels between 5 and 15 ppm. The active ingredient is extracted from 20 g medicated feed into aqueous-methanolic solvent by overnight shaking. A solid-phase extraction procedure using a 2 g C18 cartridge is then used to concentrate the active residue and remove interfering matrix components. The extracted drug and internal standard are eluted from the cartridge, evaporated to dryness, and reconstituted in methanol. A control feed sample and fortified control working standard are simultaneously prepared. Remaining interferences and sample analysis are further separated on a gradient liquid chromatographic system. Recovery of emamectin benzoate from fortified feeds ranged from 97 to 100%, with a coefficient of variation (CV) of 1.2%. Determination of emamectin benzoate in medicated feeds resulted in CVs ranging from 2.3 to 4.2% and recoveries of 88 to 98% of label claim.
Wan, Haibao; Umstot, Edward S; Szeto, Hazel H; Schiller, Peter W; Desiderio, Dominic M
2004-04-15
The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landis, E.R.; Rohrbacher, T.J.; Gluskoter, H.
1999-07-01
As part of the activities conducted under the U.S. Hungarian Science and Technology Fund, a total of 39 samples from five coal mines in Hungary were selected for standard coal analyses and major, minor and trace elements analysis. The mine areas sampled were selected to provide a spectrum of coal quality information for comparison with other coal areas in central Europe and worldwide. All of the areas are of major importance in the energy budget of Hungary. The five sample sites contain coal in rocks of Jurassic, Cretaceous, Eocene, Miocene, and Pliocene age. The coals, from four underground and onemore » surface mine, range in rank from high volatile bituminous to lignite B. Most of the coal produced from the mines sampled is used to generate electricity. Some of the power plants that utilize the coals also provide heat for domestic and process usage. The standard coal analysis program is based on tests performed in accordance with standards of the American Society for Testing and Materials (ASTM). Proximate and ultimate analyses were supplemented by determinations of the heating value, equilibrium moisture, forms of sulfur, free-swelling index, ash fusion temperatures (both reducing and oxidizing), apparent specific gravity and Hardgrove Grindability index. The major, minor and trace element analyses were performed in accordance with standardized procedures of the U.S. Geological Survey. The analytical results will be available in the International Coal Quality Data Base of the USGS. The results of the program provide data for comparison with test data from Europe and information of value to potential investors or cooperators in the coal industry of Hungary and Central Europe.« less
NASA Astrophysics Data System (ADS)
Pomata, Donatella; Di Filippo, Patrizia; Riccardi, Carmela; Buiarelli, Francesca; Gallo, Valentina
2014-02-01
Organic component of airborne particulate matter originates from both natural and anthropogenic sources whose contributions can be identified through the analysis of chemical markers. The validation of analytical methods for analysis of compounds used as chemical markers is of great importance especially if they must be determined in rather complex matrices. Currently, standard reference materials (SRM) with certified values for all those analytes are not available. In this paper, we report a method for the simultaneous determination of levoglucosan and xylitol as tracers for biomass burning emissions, and arabitol, mannitol and ergosterol as biomarkers for airborne fungi in SRM 1649a, by GC/MS. Their quantitative analysis in SRM 1649a was carried out using both internal standard calibration curves and standard addition method. A matrix effect was observed for all analytes, minor for levoglucosan and major for polyols and ergosterol. The results related to levoglucosan around 160 μg g-1 agreed with those reported by other authors, while no comparison was possible for xylitol (120 μg g-1), arabitol (15 μg g-1), mannitol (18 μg g-1), and ergosterol (0.5 μg g-1). The analytical method used for SRM 1649a was also applied to PM10 samples collected in Rome during four seasonal sampling campaigns. The ratios between annual analyte concentrations in PM10 samples and in SRM 1649a were of the same order of magnitude although particulate matter samples analyzed were collected in two different sites and periods.
IMI's teaching design, feedback system and its localization
NASA Astrophysics Data System (ADS)
Wen, Tingting; Zhang, Xuexin
2017-08-01
In Britain, the Institute of the Motor Industry (IMI) sets the National Occupational Standards for all sectors of the automotive industry. The IMI certificate and associated training programs are well recognized for its high quality both in the United Kingdom (UK) and internationally. Using China's first groups studying IMI Level 3 certificate for teachers and Level 2 certificate for students as a sample, we analyzed the seven central aspects in IMI teaching, namely, assessment standard, environment, method, content, procedure, quality control and feedback. We then proposed strategies and guidelines for its localization in China, which would be particularly important for the establishment and expansion of IMI centers.
van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F; Binder, N B; Byrne, M; Dauer, R; Gudmundsdottir, B R; Jespersen, J; Kitchen, S; Legnani, C; Lindahl, T L; Manning, R A; Martinuzzo, M; Panes, O; Pengo, V; Riddell, A; Subramanian, S; Szederjesi, A; Tantanate, C; Herbel, P; Tripodi, A
2018-01-01
Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials have been accepted by WHO as the Fifth International Standards for thromboplastin, rabbit plain, and thromboplastin, recombinant, human, plain. © 2017 International Society on Thrombosis and Haemostasis.
Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples.
Büttner, Barbara E; Öhrvik, Veronica E; Witthöft, Cornelia M; Rychlik, Michael
2011-01-01
New stable isotope dilution assays were developed for the simultaneous quantitation of [(13)C(5)]-labelled and unlabelled 5-methyltetrahydrofolic acid, 5-formyltetrahydrofolic acid, folic acid along with unlabelled tetrahydrofolic acid and 10-formylfolic acid in clinical samples deriving from human bioavailability studies, i.e. plasma, ileostomy samples, and food. The methods were based on clean-up by strong anion exchange followed by LC-MS/MS detection. Deuterated analogues of the folates were applied as the internal standards in the stable isotope dilution assays. Assay sensitivity was sufficient to detect all relevant folates in the respective samples as their limits of detection were below 0.62 nmol/L in plasma and below 0.73 μg/100 g in food or ileostomy samples. Quantification of the [(13)C(5)]-label in clinical samples offers the possibility to differentiate between folate from endogenous body pools and the administered dose when executing bioavailability trials.
High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.
Manicke, Nicholas E; Kistler, Thomas; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng
2009-02-01
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/microL. The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.