Realization of ETRF2000 as a New Terrestrial Reference Frame in Republic of Serbia
NASA Astrophysics Data System (ADS)
Blagojevic, D.; Vasilic, V.
2012-12-01
The International Earth Rotation and Reference Systems Service (IERS) is a joint service of the International Association of Geodesy (IAG) and the International Astronomical Union (IAU), which provides the scientific community with the means for computing the transformation from the International Celestial Reference System (ICRS) to the International Terrestrial Reference System (ITRS). It further maintains the realizations of these systems by appropriate coordinate sets called "frames". The densification of terrestrial frame usually serves as official frame for positioning and navigation tasks within the territory of particular country. One of these densifications was recently performed in order to establish new reference frame for Republic of Serbia. The paper describes related activities resulting in ETRF2000 as a new Serbian terrestrial reference frame.
Definition and Proposed Realization of the International Height Reference System (IHRS)
NASA Astrophysics Data System (ADS)
Ihde, Johannes; Sánchez, Laura; Barzaghi, Riccardo; Drewes, Hermann; Foerste, Christoph; Gruber, Thomas; Liebsch, Gunter; Marti, Urs; Pail, Roland; Sideris, Michael
2017-05-01
Studying, understanding and modelling global change require geodetic reference frames with an order of accuracy higher than the magnitude of the effects to be actually studied and with high consistency and reliability worldwide. The International Association of Geodesy, taking care of providing a precise geodetic infrastructure for monitoring the Earth system, promotes the implementation of an integrated global geodetic reference frame that provides a reliable frame for consistent analysis and modelling of global phenomena and processes affecting the Earth's gravity field, the Earth's surface geometry and the Earth's rotation. The definition, realization, maintenance and wide utilization of the International Terrestrial Reference System guarantee a globally unified geometric reference frame with an accuracy at the millimetre level. An equivalent high-precision global physical reference frame that supports the reliable description of changes in the Earth's gravity field (such as sea level variations, mass displacements, processes associated with geophysical fluids) is missing. This paper addresses the theoretical foundations supporting the implementation of such a physical reference surface in terms of an International Height Reference System and provides guidance for the coming activities required for the practical and sustainable realization of this system. Based on conceptual approaches of physical geodesy, the requirements for a unified global height reference system are derived. In accordance with the practice, its realization as the International Height Reference Frame is designed. Further steps for the implementation are also proposed.
[On the way to national reference system of laboratory medicine].
Muravskaia, N P; Men'shikov, V V
2014-10-01
The application of standard samples and reference techniques of implementation of measurements is needed for a valid support of reliability of analyses applied in clinical diagnostic laboratories. They play role of landmarks under metrologic monitoring, calibration of devices and control of quality of results. The article presents analysis of shortcomings interfering with formation of national reference system in Russia harmonized with possibilities provided by international organizations. Among them are the joint Committee on metrologic monitoring in laboratory medicine under the auspices of the International Bureau of Weights and Measures, the International Federation of clinical chemistry and laboratory medicine, etc. The results of the recent development of national normative documents, standard samples and techniques assisted by the authors of article are considered. They are the first steps to organization of national reference system which would comprise all range of modern analytical technologies of laboratory medicine. The national and international measures are proposed to enhance the promptest resolving of task of organization of national reference system for laboratory medicine in the interests of increasing of effectiveness of medical care to citizen of Russia.
Focus Upon Implementing the GGOS Decadal Vision for Geohazards Monitoring
NASA Astrophysics Data System (ADS)
LaBrecque, John; Stangl, Gunter
2017-04-01
The Global Geodetic Observing System of the IAG identified present and future roles for Geodesy in the development and well being of the global society. The GGOS is focused upon the development of infrastructure, information, analysis, and educational systems to advance the International Global Reference Frame, the International Celestial Reference System, the International Height Reference System, atmospheric dynamics, sea level change and geohazards monitoring. The geohazards initiative is guided by an eleven nation working group initially focused upon the development and integration of regional multi-GNSS networks and analysis systems for earthquake and tsunami early warning. The opportunities and challenges being addressed by the Geohazards working group include regional network design, algorithm development and implementation, communications, funding, and international agreements on data access. This presentation will discuss in further detail these opportunities and challenges for the GGOS focus upon earthquake and tsunami early warning.
ERIC Educational Resources Information Center
Schaumann, Leif
Intended as a companion piece to volume 7 in the Method Series, Pharmaceutical Supply System Planning (CE 024 234), this fifth of six volumes in the International Health Planning Reference Series is a combined literature review and annotated bibliography dealing with alternative methodologies for planning and analyzing pharmaceutical supply…
The gravity field observations and products at IGFS
NASA Astrophysics Data System (ADS)
Barzaghi, Riccardo; Vergos, George; Bonvalot, Sylvain; Barthelmes, Franz; Reguzzoni, Mirko; Wziontek, Hartmut; Kelly, Kevin
2017-04-01
The International Gravity Field Service (IGFS) is a service of the International Association of Geodesy (IAG) that was established in 2003 at the IAG/IUGG General Assembly in Sapporo (Japan). This service aims at coordinating the actions of the IAG services related to the Earth gravity field, i.e. the Bureau Gravimétrique International (BGI), the International Service for the Geoid (ISG), the International Geodynamics and Earth Tides Service (IGETS), the International Center for Global Earth Models (ICGEM) and the International Digital Elevation Model Service (IDEMS). Also, via its Central Bureau hosted at the Aristotle University of Thessaloniki (Greece), IGFS provides a link to the Global Geodetic Observing System (GGOS) bureaus in order to communicate their requirements and recommendations to the IGFS-Centers. In this work, a presentation is given on the recent activities of the service, namely those related to the contributions to the implementation of: the International Height Reference System/Frame; the Global Geodetic Reference System/Frame; the new Global Absolute Gravity Reference System/Frame. Particularly, the impact that these activities have in improving the estimation of the Earth's gravity field, either at global and local scale, is highlighted also in the framework of GGOS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trappl, R.; Findler, N.V.; Horn, W.
1982-01-01
This book covers current research topics in six areas. These are data base design, international information systems, semiotic systems, artificial intelligence, cybernetics and philosophy, and special aspects of systems research. 1326 references.
NASA Astrophysics Data System (ADS)
Fey, A. L.; Gordon, D.; Jacobs, C. S.; Ma, C.; Gaume, R. A.; Arias, E. F.; Bianco, G.; Boboltz, D. A.; Böckmann, S.; Bolotin, S.; Charlot, P.; Collioud, A.; Engelhardt, G.; Gipson, J.; Gontier, A.-M.; Heinkelmann, R.; Kurdubov, S.; Lambert, S.; Lytvyn, S.; MacMillan, D. S.; Malkin, Z.; Nothnagel, A.; Ojha, R.; Skurikhina, E.; Sokolova, J.; Souchay, J.; Sovers, O. J.; Tesmer, V.; Titov, O.; Wang, G.; Zharov, V.
2015-08-01
We present the second realization of the International Celestial Reference Frame (ICRF2) at radio wavelengths using nearly 30 years of Very Long Baseline Interferometry observations. ICRF2 contains precise positions of 3414 compact radio astronomical objects and has a positional noise floor of ∼40 μas and a directional stability of the frame axes of ∼10 μas. A set of 295 new “defining” sources was selected on the basis of positional stability and the lack of extensive intrinsic source structure. The positional stability of these 295 defining sources and their more uniform sky distribution eliminates the two greatest weaknesses of the first realization of the International Celestial Reference Frame (ICRF1). Alignment of ICRF2 with the International Celestial Reference System was made using 138 positionally stable sources common to both ICRF2 and ICRF1. The resulting ICRF2 was adopted by the International Astronomical Union as the new fundamental celestial reference frame, replacing ICRF1 as of 2010 January 1.
International energy outlook 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-05-01
This International Energy Outlook presents historical data from 1970 to 1993 and EIA`s projections of energy consumption and carbon emissions through 2015 for 6 country groups. Prospects for individual fuels are discussed. Summary tables of the IEO96 world energy consumption, oil production, and carbon emissions projections are provided in Appendix A. The reference case projections of total foreign energy consumption and of natural gas, coal, and renewable energy were prepared using EIA`s World Energy Projection System (WEPS) model. Reference case projections of foreign oil production and consumption were prepared using the International Energy Module of the National Energy Modeling Systemmore » (NEMS). Nuclear consumption projections were derived from the International Nuclear Model, PC Version (PC-INM). Alternatively, nuclear capacity projections were developed using two methods: the lower reference case projections were based on analysts` knowledge of the nuclear programs in different countries; the upper reference case was generated by the World Integrated Nuclear Evaluation System (WINES)--a demand-driven model. In addition, the NEMS Coal Export Submodule (CES) was used to derive flows in international coal trade. As noted above, foreign projections of electricity demand are now projected as part of the WEPS. 64 figs., 62 tabs.« less
NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
Search Codes for a Bibliography for the Study of African International Relations
1975-01-01
Soja (1970). A high speed ln-house reference system was needed to facilitate storage, search, and retrieval of bibliographic reference materlal...REfUBLIC 0F (N0R™ KUW KUWAIT LAB LABOR UNIONS, INTERNATIONAL ASPECTS l- LA LAND LOCKED NATIONS LAO LAOS LAT LATIN AliERICA LAW I AW, INTERNATIONAL...IOCRATIC PEOPLE’S REPUBLIC OF (NORTH) KÜS KOREA (SOUTH) KUW KUWA I T LAb LABOR UNIONS, INTERNATIONAL ASPECTS LAU LA )S I.AT LATIN AiiEUICA LAN
The Internal Control System and Control Programs: A Reference Guide
1990-06-01
multilocation audits . [Ref. 27:Ch. 8, p. 4] 3. Verification Staqe The actual audit field work occurs during this phase. The audit team provides an entrance...number) ;E, GUO.)P SuB GROUP Internal Control; Internal Control System; Audits ; Reviews; Ccamand Evaluation Program; EconnTy & Efficiency Reviews...general overview of the inter- nal control system and discusses the various external and internal audits , inspections, reviews and investiaative
International Access to Bibliographic Data: MARC and MARC-Related Activities.
ERIC Educational Resources Information Center
Hopkinson, Alan
1984-01-01
This review of international information exchange formats focuses on the international standard ISO 2709 and MARC formats, "UNISIST Reference Manual," UNIMARC (Universal MARC format), the Common Communications Format, centralized network formats (International Serials Data System, MINISIS, regional), International MARC network study…
46 CFR 95.01-2 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for the Installation of Sprinkler Systems, incorporation by reference approved for § 95.30-1. (2... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE... Specification for International Shore Connections for Marine Fire Applications, incorporation by reference...
46 CFR 193.01-3 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for the Installation of Sprinkler Systems, incorporation by reference approved for § 193.30-1. (2... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... Specification for International Shore Connections for Marine Fire Applications, incorporation by reference...
46 CFR 193.01-3 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for the Installation of Sprinkler Systems, incorporation by reference approved for § 193.30-1. (2... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... Specification for International Shore Connections for Marine Fire Applications, incorporation by reference...
46 CFR 95.01-2 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for the Installation of Sprinkler Systems, incorporation by reference approved for § 95.30-1. (2... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE... Specification for International Shore Connections for Marine Fire Applications, incorporation by reference...
The Determination of Earth Orientation by VLBI and GNSS: Principles and Results
NASA Astrophysics Data System (ADS)
Capitaine, Nicole
2017-10-01
The Earth Orientation Parameters (EOP) connect the International Terrestrial Reference System (ITRS) to the Geocentric Celestial Reference System (GCRS). These parameters, i.e., Universal Time, UT1, and pole coordinates in the ITRS and in the GCRS, describe the irregularities of the Earth's rotation. They are mainly determined by two modern astro-geodetic techniques, VLBI (Very Long Baseline Radio Interferometry) on extragalactic radio sources, which is used to realize and maintain the International Celestial Reference System (ICRS), and Global Navigation Satellite System (GNSS), especially GPS (Global Positioning System), which has an important contribution to the realization of the ITRS. The aim of this presentation is twofold: to present the modern bases for the consider- ation of Earth orientation and to discuss how the principles of VLBI and GPS give access to the measure of different components of the EOP variations, especially UT1. The accuracy that can be achieved is based on the improved concepts, definitions, and models that have been adopted by IAU/IUGG resolutions on reference systems and Earth's rotation, as well as on the refined strategy of the observations.
New International Agreements About Space Techniques Among Argentina, China and France
NASA Astrophysics Data System (ADS)
Pacheco, A. M.; Podestá, R.; Actis, E.; Adarvez, S.; Quinteros, J.; Li, J.; Saunier, J.; Podestá, F.; Ramos, F.; Aguilera, J.; Sosa, G.; Hauser, D.
2018-01-01
The International Earth Rotation and Reference Systems (IERS) is in charge of defining and materializing celestial reference systems (ICRS - ICRF) and terrestrial reference systems (ITRS - ITRF). In order to perform this task it uses data from the following techniques: Very Long Baseline Interferometry (VLBI), Satellite Laser Ranging (SLR), Global Navigation Satellite System (GNSS) and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS). Nowadays, the Observatorio Astronómico Félix Aguilar (OAFA) has two instruments with these advanced techniques: SLR and a permanent GNSS station. In the nearby future a 40 m diameter radio telescope will be available that will be operated in VLBI mode along with a DORIS buoy which will be co-localized with a SLR telescope and GNSS antennas. In this way OAFA will become a zero station, first class, of the ITRF 2014 frame.
International Laser Ranging Service (ILRS) 2003-2004 Annual Report
NASA Technical Reports Server (NTRS)
Pearlman, Michael (Editor); Noll, Carey (Editor)
2005-01-01
The International Laser Ranging Service (ILRS) organizes and coordinates Satellite Laser Ranging (SLR) and Lunar Laser Ranging (LLR) to support programs in geodetic, geophysical, and lunar research activities and provides the International Earth Rotation and Reference Systems Service (IERS) with products important to the maintenance of an accurate International Terrestrial Reference Frame (ITRF). This reference frame provides the stability through which systematic measurements of the Earth can be made over thousands of kilometers, decades of time, and evolution of measurement technology. This 2003-2004 ILRS annual report is comprised of individual contributions from ILRS components within the international geodetic community for the years 2003-2004. The report documents changes and progress of the ILRS and is also available on the ILRS Web site at http://ilrs.gsfc.nasa.gov/reports/ilrs_reports/ilrsar_2003.html.
Reference dosimeter system of the iaea
NASA Astrophysics Data System (ADS)
Mehta, Kishor; Girzikowsky, Reinhard
1995-09-01
Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.
Towards a first realization of the International Height Reference System (IHRS)
NASA Astrophysics Data System (ADS)
Sanchez, Laura; Ihde, Johannes; Pail, Roland; Gruber, Thomas; Barzaghi, Riccardo; Marti, Urs; Agren, Jonas; Sideris, Michael; Novak, Pavel
2017-04-01
The IAG Resolution No. 1 released during the IUGG 2015 General Assembly outlines five conventions for the definition of the International Height Reference System (IHRS). The definition is given in terms of potential parameters: the vertical coordinates are geopotential numbers referring to an equipotential surface of the Earth's gravity field realized by the conventional value W0 = 62 636 853.4 m2s-2. The spatial reference of the position P for the potential W(P) = W(X) is given by coordinates X of the International Terrestrial Reference Frame (ITRF). This Resolution also states that parameters, observations, and data shall be related to the mean tidal system/mean crust. At present, the main challenge is the realization of the IHRS; i.e., the establishment of the International Height Reference Frame (IHRF). It is expected that the IHRF follows the same structure as the ITRF: a global network with regional and national densifications, whose geopotential numbers referring to the global IHRS are known. According to the GGOS objectives, the target accuracy of these global geopotential numbers is 1 x 10-2 m2s-2. In practice, the precise realization of the IHRS is limited by different aspects; for instance, no unified standards or methods for the determination of the potential values W(P); application of different conventions for the gravity field modelling and the estimation of the position vectors X; inhomogeneous distribution of the geodetic infrastructure; restricted accessibility to terrestrial gravity data to increase the GGM resolution; insufficient modelling of geodynamic phenomena, etc. This may restrict the expected accuracy of 1 x 10-2 m2s-2 to some orders lower (from 10 x 10-2 m2s-2 to 100 x 10-2 m2s-2). This contribution discusses the required steps to outline a sustainable realization of the IHRS.
Microcomputer-Based Access to Machine-Readable Numeric Databases.
ERIC Educational Resources Information Center
Wenzel, Patrick
1988-01-01
Describes the use of microcomputers and relational database management systems to improve access to numeric databases by the Data and Program Library Service at the University of Wisconsin. The internal records management system, in-house reference tools, and plans to extend these tools to the entire campus are discussed. (3 references) (CLB)
Kristianslund, Eirik; Krosshaug, Tron; Mok, Kam-Ming; McLean, Scott; van den Bogert, Antonie J
2014-01-03
Joint moments help us understand joint loading and muscle function during movement. However, the interpretation depends on the choice of reference frame, but the different reference frames have not been compared in dynamic, high-impact sporting movements. We have compared the magnitude and the resulting ranking of hip and knee joint moments expressed in the laboratory coordinate system, the local system of the distal segment and projected or decomposed to the Joint Coordinate System (JCS) axes. Hip and knee joint moments of drop jumps and sidestep cutting in 70 elite female handball players were calculated based on recordings from an eight-camera 240 Hz system and two force platforms and expressed with the four methods. The greatest variations in magnitude between conditions were seen for drop jump hip internal rotation (range: 0.31-0.71 Nm/kg) and sidestep cutting knee flexion (2.87-3.39 Nm/kg) and hip internal rotation (0.87-2.36 Nm/kg) and knee internal rotation (0.10-0.40 Nm/kg) moments. The rank correlations were highest between conditions for flexion moments (0.88-1.00) and sidestep cutting abduction moments (0.71-0.98). The rank correlations ranged from 0.64 to 0.73 for drop jump knee abduction moments and between -0.17 and 0.67 for hip and knee internal rotation moments. Expression of joint moments in different reference systems affects the magnitude and ranking of athletes. This lack of consistency may complicate the comparison and combination of results. Projection to the JCS is the only method where joint moments correspond to muscle and ligament loading. More widespread adoption of this convention could facilitate comparison of studies and ease the interpretation of results. © 2013 Elsevier Ltd. All rights reserved.
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
Why the Greenwich Meridian Moved
2015-08-01
that are related to the geocentric reference frame introduced by the Bureau International de l’Heure (BIH) in 1984. This BIHTerrestrial System provided...the basis for orientation of subsequent geocentric reference frames, including all realizations of theWorld Geodetic Sys- tem 1984 and the...astronomical time. The coordinates of satellite-navigation receivers are provided in reference frames that are related to the geocentric reference
On transformation between international celestial and terrestrial reference systems
NASA Astrophysics Data System (ADS)
Bretagnon, P.; Brumberg, V. A.
2003-09-01
Based on the current IAU hierarchy of the relativistic reference systems, practical formulae for the transformation between barycentric (BCRS) and geocentric (GCRS) celestial reference systems are derived. BCRS is used to refer to ICRS, International Celestial Reference System. This transformation is given in four versions, dependent on the time arguments used for BCRS (TCB or TDB) and for GCRS (TCG or TT). All quantities involved in these formulae have been tabulated with the use of the VSOP theories (IMCCE theories of motion of the major planets). In particular, these formulae may be applied to account for the indirect relativistic third-body perturbations in motion of Earth's satellites and Earth's rotation problem. We propose to use the SMART theory (IMCCE theory of Earth's rotation) in constructing the Newtonian three-dimensional spatial rotation transformation between GCRS and ITRS, the International Terrestrial Reference System. This transformation is compared with two other versions involving extra angular variables currently used by IERS, the International Earth Rotation Service. It is shown that the comparison of these three forms of the same transformation may be greatly simplified by using the proposed composite rotation formula. Tables 1-20 of Appendix B containing the initial terms of the VSOP-based series for the BCRS<->GCRS transformation are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/408/387. The work on ICRS<->GCRS transformation with the use of VSOP theories was done in February-March 2002 during the stay of the second author in IMCCE. The authors hoped to complete the second part concerning GCRS<->ITRS transformation with the use of SMART theory in September 2002 during the visit of the first author to IAA. The grave disease of Pierre Bretagnon which tragically resulted in his death on November 17, 2002, did not permit us to complete this work. The aim to improve SMART theory by taking into account the indirect relativistic third-body perturbations as indicated in the paper also remains unachieved. The second author is publishing this paper in memoriam of
75 FR 5351 - Proposed Revisions to Accounting Guide for LSC Recipients
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-02
... elements of an adequate accounting and financial reporting system, including the use of specific internal... checklist of accounting procedures and internal controls. The proposed revisions update the checklist to... accounting procedures and internal controls to reflect current best practices; (7) updated and new references...
14 CFR 36.6 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: AIRCRAFT TYPE AND AIRWORTHINESS CERTIFICATION General § 36.6 Incorporation by reference. (a... 61265, entitled “Instruments for Measurement of Aircraft Noise-Performance Requirements for Systems to... publications. (i) International Electrotechnical Commission, 3, rue de Varembe, Case postale 131, 1211 Geneva...
Comparative Elections: Building a Basic Reference Collection.
ERIC Educational Resources Information Center
Nalen, James E.
2001-01-01
This annotated bibliography focuses on resources for the study of international elections and electoral systems and outcomes that will be useful for collection development and for answering reference questions about foreign elections. Discusses comparative politics, comparative elections, and possible electoral reform. (LRW)
Grønbæk, Anni Birgitte; Petersen, Flemming; Haubek, Dorte; Poulsen, Sven
2017-11-01
To describe a population-based organization of dentoalveolar surgical service for 0 to 18-year old subjects in a Danish municipal dental service, and analyze the type of dentoalveolar surgical interventions needed. The study was conducted in the Municipality of Aarhus, Denmark during five consecutive school-years. An internal referral system was established within the municipality where patients could be referred to colleagues with a higher level of competencies and more experiences with paediatric dentoalveolar surgery. The analysis includes a total of 1812 children and a total of 2854 surgical interventions. Almost 80% of the patients, representing more than 80% of the dentoalveolar surgical interventions needed, were referred internally. Denudations were the most frequent treatment type (40.3%) carried out, followed by removal of third molars (18.0%). Furthermore, 22 odontomas and 100 supernumerary teeth were removed. The need of dentoalveolar surgery in children and adolescents is relatively low, but includes a wide range of interventions. An organizational system, where dentists can refer to colleagues who have developed special competencies in this field, results in most of these surgical patients being referred and treated internally.
2004-12-01
Origins of Alliances by Stephen M . Walt The Balance of Power: Stability in International Systems by Emerson M . S. Niou, Peter C . Ordeshook and...Stability in International Systems by Emerson M . S. Niou, Peter C . Ordeshook and Gregory F. Rose." International Organization, no. 45 (Winter 1991...1 B. MAIN QUESTIONS AND ARGUMENTS .............................................. 2 C . METHODOLOGY AND SOURCES
The International Geomagnetic Reference Field, 2005
Rukstales, Kenneth S.; Love, Jeffrey J.
2007-01-01
This is a set of five world charts showing the declination, inclination, horizontal intensity, vertical component, and total intensity of the Earth's magnetic field at mean sea level at the beginning of 2005. The charts are based on the International Geomagnetic Reference Field (IGRF) main model for 2005 and secular change model for 2005-2010. The IGRF is referenced to the World Geodetic System 1984 ellipsoid. Additional information about the USGS geomagnetism program is available at: http://geomag.usgs.gov/
Data Assimilation as a Tool for Developing a Mars International Reference Atmosphere
NASA Technical Reports Server (NTRS)
Houben, Howard
2005-01-01
A new paradigm for a Mars International Reference Atmosphere is proposed. In general, as is certainly now the case for Mars, there are sufficient observational data to specify what the full atmospheric state was under a variety of circumstances (season, dustiness, etc.). There are also general circulation models capable of deter- mining the evolution of these states. If these capabilities are combined-using data assimilation techniques-the resulting analyzed states can be probed to answer a wide variety of questions, whether posed by scientists, mission planners, or others. This system would fulfill all the purposes of an international reference atmosphere and would make the scientific results of exploration missions readily available to the community. Preliminary work on a website that would incorporate this functionality has begun.
Indicator system provides complete data of engine cylinder pressure variation
NASA Technical Reports Server (NTRS)
Mc Jones, R. W.; Morgan, N. E.
1966-01-01
Varying reference pressure used together with a balanced pressure pickup /a diaphragm switch/ to switch the electric output of the pressure transducer in a reference pressure line obtains precise engine cylinder pressure data from a high speed internal combustion engine.
The gallium melting-point standard: its role in our temperature measurement system.
Mangum, B W
1977-01-01
The latest internationally-adopted temperature scale, the International Practical Temperature Scale of 1968 (amended edition of 1975), is discussed in some detail and a brief description is given of its evolution. The melting point of high-purity gallium (stated to be at least 99.99999% pure) as a secondary temperature reference point is evaluated. I believe that this melting-point temperature of gallium should be adopted by the various medical professional societies and voluntary standards groups as the reaction temperature for enzyme reference methods in clinical enzymology. Gallium melting-point cells are available at the National Bureau of Standards as Standard Reference Material No. 1968.
Isotopic Constraints on the Sources and Associations of Organic Compounds in Marine Sediments
2006-02-01
international standard for 14C dating, Standard Reference Material 4990B " Oxalic Acid". Routine precision for 813 C and Aa4 C measurements are --0.1 and...determined by their depositional settings. Group ’a’ includes organic-rich marine sediments from Guaymas basin (GB), a hydrothermal system with active...is the per mille (%0o) deviation from the international standard for 14C dating, Standard Reference Material 4990B " Oxalic Acid". Precision for V C
The International GPS Service (IGS) as a Continuous Reference System for Precise GPS Positioning
NASA Technical Reports Server (NTRS)
Neilan, Ruth; Heflin, Michael; Watkins, Michael; Zumberge, James
1996-01-01
The International GPS Service for Geodynamics (IGS) is an organization which operates under the auspices of the International Association of Geodesy (IAG) and has been operational since January 1994. The primary objective of the IGS is to provide precise GPS data and data products to support geodetic and geophysical research activities.
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
NASA Technical Reports Server (NTRS)
1981-01-01
The use of an International Standards Organization (ISO) Open Systems Interconnection (OSI) Reference Model and its relevance to interconnecting an Applications Data Service (ADS) pilot program for data sharing is discussed. A top level mapping between the conjectured ADS requirements and identified layers within the OSI Reference Model was performed. It was concluded that the OSI model represents an orderly architecture for the ADS networking planning and that the protocols being developed by the National Bureau of Standards offer the best available implementation approach.
The Neural Network In Coordinate Transformation
NASA Astrophysics Data System (ADS)
Urusan, Ahmet Yucel
2011-12-01
In international literature, Coordinate operations is divided into two categories. They are coordinate conversion and coordinate transformation. Coordinates converted from coordinate system A to coordinate system B in the same datum (mean origine, scale and axis directions are same) by coordinate conversion. There are two different datum in coordinate transformation. The basis of each datum to a different coordinate reference system. In Coordinate transformation, coordinates are transformed from coordinate reference system A to coordinate referance system B. Geodetic studies based on physical measurements. Coordinate transformation needs identical points which were measured in each coordinate reference system (A and B). However it is difficult (and need a big reserved budget) to measure in some places like as top of mountain, boundry of countries and seaside. In this study, this sample problem solution was researched. The method of learning which is one of the neural network methods, was used for solution of this problem.
Human Exploration of Mars Design Reference Architecture 5.0
NASA Technical Reports Server (NTRS)
Drake, Bret G.; Hoffman, Stephen J.; Beaty, David W.
2009-01-01
This paper provides a summary of the 2007 Mars Design Reference Architecture 5.0 (DRA 5.0), which is the latest in a series of NASA Mars reference missions. It provides a vision of one potential approach to human Mars exploration including how Constellation systems can be used. The reference architecture provides a common framework for future planning of systems concepts, technology development, and operational testing as well as Mars robotic missions, research that is conducted on the International Space Station, and future lunar exploration missions. This summary the Mars DRA 5.0 provides an overview of the overall mission approach, surface strategy and exploration goals, as well as the key systems and challenges for the first three human missions to Mars.
The Egocentric Reference for Visual Exploration and Orientation
ERIC Educational Resources Information Center
Nico, Daniele; Daprati, Elena
2009-01-01
Clinical signs of damage to the egocentric reference system range from the inability to detect stimuli in the real environment to a defect in recovering items from an internal representation. Despite clinical dissociations, current interpretations consider all symptoms as due to a single perturbation, differentially expressed according to the…
NASA Technical Reports Server (NTRS)
Laurini, Kathleen C.; Hufenbach, Bernhard; Junichiro, Kawaguchi; Piedboeuf, Jean-Claude; Schade, Britta; Lorenzoni, Andrea; Curtis, Jeremy; Hae-Dong, Kim
2010-01-01
The International Space Exploration Coordination Group (ISECG) was established in response to The Global Exploration Strategy: The Framework for Coordination developed by fourteen space agencies and released in May 2007. Several ISECG participating space agencies have been studying concepts for human exploration of the moon that allow individual and collective goals and objectives to be met. This 18 month study activity culminated with the development of the ISECG Reference Architecture for Human Lunar Exploration. The reference architecture is a series of elements delivered over time in a flexible and evolvable campaign. This paper will describe the reference architecture and how it will inform near-term and long-term programmatic planning within interested agencies. The reference architecture is intended to serve as a global point of departure conceptual architecture that enables individual agency investments in technology development and demonstration, International Space Station research and technology demonstration, terrestrial analog studies, and robotic precursor missions to contribute towards the eventual implementation of a human lunar exploration scenario which reflects the concepts and priorities established to date. It also serves to create opportunities for partnerships that will support evolution of this concept and its eventual realization. The ISECG Reference Architecture for Human Lunar Exploration (commonly referred to as the lunar gPoD) reflects the agency commitments to finding an effective balance between conducting important scientific investigations of and from the moon, as well as demonstrating and mastering the technologies and capabilities to send humans farther into the Solar System. The lunar gPoD begins with a robust robotic precursor phase that demonstrates technologies and capabilities considered important for the success of the campaign. Robotic missions will inform the human missions and buy down risks. Human exploration will start with a thorough scientific investigation of the polar region while allowing the ability to demonstrate and validate the systems needed to take humans on more ambitious lunar exploration excursions. The ISECG Reference Architecture for Human Lunar Exploration serves as a model for future cooperation and is documented in a summary report and a comprehensive document that also describes the collaborative international process that led to its development. ISECG plans to continue with architecture studies such as this to examine an open transportation architecture and other destinations, with expanded participation from ISECG agencies, as it works to inform international partnerships and advance the Global Exploration Strategy.
Fibrinolysis standards: a review of the current status.
Thelwell, C
2010-07-01
Biological standards are used to calibrate measurements of components of the fibrinolytic system, either for assigning potency values to therapeutic products, or to determine levels in human plasma as an indicator of thrombotic risk. Traditionally WHO International Standards are calibrated in International Units based on consensus values from collaborative studies. The International Unit is defined by the response activity of a given amount of the standard in a bioassay, independent of the method used. Assay validity is based on the assumption that both standard and test preparation contain the same analyte, and the response in an assay is a true function of this analyte. This principle is reflected in the diversity of source materials used to prepare fibrinolysis standards, which has depended on the contemporary preparations they were employed to measure. With advancing recombinant technology, and improved analytical techniques, a reference system based on reference materials and associated reference methods has been recommended for future fibrinolysis standards. Careful consideration and scientific judgement must however be applied when deciding on an approach to develop a new standard, with decisions based on the suitability of a standard to serve its purpose, and not just to satisfy a metrological ideal. 2010 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.
39 CFR 20.1 - International Mail Manual; incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
... reference. 20.1 Section 20.1 Postal Service UNITED STATES POSTAL SERVICE INTERNATIONAL MAIL INTERNATIONAL POSTAL SERVICE § 20.1 International Mail Manual; incorporation by reference. (a) Section 552(a) of Title... provided in this part, the U.S. Postal Service hereby incorporates by reference its International Mail...
ERIC Educational Resources Information Center
Lenkeit, Jenny; Caro, Daniel H.
2014-01-01
Reports of international large-scale assessments tend to evaluate and compare education system performance based on absolute scores. And policymakers refer to high-performing and economically prosperous education systems to enhance their own systemic features. But socioeconomic differences between systems compromise the plausibility of those…
Development Requirements for Spacesuit Elbow Joint
NASA Technical Reports Server (NTRS)
Peters, Benjamin
2017-01-01
Functional Requirements for spacesuit elbow joint:1) The system is a conformal, single-axis spacesuit pressurized joint that encloses the elbow joint of the suited user and uses a defined interface to connect to the suit systems on either side of the joint.2) The system shall be designed to bear the loads incurred from the internal pressure of the system, as well as the expected loads induced by the user while enabling the user move the joint through the required range of motion. The joint torque of the system experienced by the user shall remain at or below the required specification for the entire range of motion.3) The design shall be constructed, at a minimum, as a two-layer system. The internal, air-tight layer shall be referred to as the bladder, and the layer on the unpressurized side of the bladder shall be referred to as the restraint. The design of the system may include additional features or layers, such as axial webbing, to meet the overall requirements of the design.
The Control Based on Internal Average Kinetic Energy in Complex Environment for Multi-robot System
NASA Astrophysics Data System (ADS)
Yang, Mao; Tian, Yantao; Yin, Xianghua
In this paper, reference trajectory is designed according to minimum energy consumed for multi-robot system, which nonlinear programming and cubic spline interpolation are adopted. The control strategy is composed of two levels, which lower-level is simple PD control and the upper-level is based on the internal average kinetic energy for multi-robot system in the complex environment with velocity damping. Simulation tests verify the effectiveness of this control strategy.
2009-04-08
The Food and Drug Administration (FDA) is announcing the availability of a guidance entitled "Q10 Pharmaceutical Quality System." The guidance was prepared under the auspices of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). The guidance describes a model for an effective quality management system for the pharmaceutical industry, referred to as the Pharmaceutical Quality System. The guidance is intended to provide a comprehensive approach to an effective pharmaceutical quality system that is based on International Organization for Standardization (ISO) concepts, includes applicable good manufacturing practice (GMP) regulations and complements ICH guidances on "Q8 Pharmaceutical Development" and "Q9 Quality Risk Management."
GPS-Only Terrestrial Reference Frame Based on a Global Reprocessing
NASA Astrophysics Data System (ADS)
Dietrich, R.; Rothacher, M.; Ruelke, A.; Fritsche, M.; Steigenberger, P.
2007-12-01
The realization of the International Terrestrial Reference System (ITRS) with highest accuracy and stability is fundamental and crucial for applications in geodesy, geodynamics, geophysics and global change. In a joint effort TU Dresden and TU Munich/GFZ Potsdam reprocessed a global GPS network of more than 200 stations. As a contribution to an ITRS realization daily normal equations from 1994 to 2005 were rigorously combined in order to determine a global GPS-only reference frame (PDR05/Potsdam-Dresden-Reprocessing Reference Frame). We present a realization of the global terrestrial reference system which follows the center of mass approach in consideration of the load-induced deformation of the Earth's crust due to the redistribution of surface masses. The stability of our reference frame will be evaluated based on the obtained long-term trends of station coordinates, the load-induced deformation estimates and the homogeneous time series of station positions. We will compare our solution with other recent terrestrial reference system realizations and give some conclusions for future realizations of the ITRS.
Status of NGS CORS Network and Its Contribution to the GGOS Infrastructure
NASA Astrophysics Data System (ADS)
Choi, K. K.; Haw, D.; Sun, L.
2017-12-01
Recent advancement of Satellite Geodesy techniques can now contribute to the global frame realization needed to improve worldwide accuracies. These techniques rely on coordinates computed using continuously observed GPS data and corresponding satellite orbits. The GPS-based reference system continues to depend on the physical stability of a ground-based network of points as the primary foundation for these observations. NOAA's National Geodetic Survey (NGS) has been operating Continuously Operating Reference Stations (CORS) to provide direct access to the National Spatial Reference System (NSRS). By virtue of NGS' scientific reputation and leadership in national and international geospatial issues, NGS has determined to increase its participation in the maintenance of the U.S. component of the global GPS tracking network in order to realize a long-term stable national terrestrial reference frame. NGS can do so by leveraging its national leadership role coupled with NGS' scientific expertise, in designating and upgrading a subset of the current tracking network for this purpose. This subset of stations must have the highest operational standards to serve the dual functions: being the U.S. contribution to the international frame, along with providing the link to the national datum. These stations deserve special attention to ensure that the highest possible levels of quality and stability are maintained. To meet this need, NGS is working with the international scientific groups to add and designate these reference stations based on scientific merit such as: colocation with other geodetic techniques, geographic area, and monumentation stability.
Microarsecond models for the celestial motions of the CIP and CEO
NASA Astrophysics Data System (ADS)
Capitaine, N.
2004-09-01
The Celestial intermediate pole (CIP) and Celestial ephemeris (orintermediate) origin (CEO/CIO) have been adopted by the IAU (c.f. IAU2000 Resolution B1.8) as the celestial pole and origin, respectively,to be used for realizing the intermediate celestial system between theInternational Terrestrial System (ITRS) and Geocentric CelestialReference System (GCRS). Resolution B1.8 has also recommended that theInternational Earth Rotation and Reference Systems Service (IERS)continue to provide users with data and algorithms for the conventionaltransformation. The IAU 2000 Resolutions have been implemented in theIERS 2003 Conventions including Tables and routines that provide thecelestial motions of the CIP and the CEO with a theoretical accuracy ofone microarcsecond after one century using either the classical or thenew transformation. This paper reports on the method used for achievingthis accuracy in the positions of the CIP and CIO and on the differencebetween this rigorous procedure and the pre-2003 classical one.
[Brief disserting on the balance of internal environment in burn disease].
Han, C M; Wang, X G
2017-08-20
The essential internal environment in human being involves water, electrolyte, and acid-base balance, which is the basis of balance and stability of internal environment in other systems. For burn patients, the balance of internal environment, referring to metabolism, nutrition, inflammatory response, and immunoreaction, is one of the most important aspects in burn disease. This paper aims to briefly elaborate the balance of internal environment after burn, with the purpose to promote the basic and clinical research in this field.
78 FR 1735 - Airworthiness Directives; Honeywell International Inc. Air Data Pressure Transducers
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-09
... reviewed Honeywell Alert Service Bulletin ADM/ADC/ADAHRS-34-A01, dated November 6, 2012. This service...), air data computers, air data attitude heading reference systems, and digital air data computers... fails. Honeywell Service Bulletin ACM/ADC/ADAHRS-34-A01, dated November 6, 2012, specifies to refer to...
Human Exploration of Mars Design Reference Architecture 5.0
NASA Technical Reports Server (NTRS)
Drake, Bret G.
2010-01-01
This paper provides a summary of the Mars Design Reference Architecture 5.0 (DRA 5.0), which is the latest in a series of NASA Mars reference missions. It provides a vision of one potential approach to human Mars exploration. The reference architecture provides a common framework for future planning of systems concepts, technology development, and operational testing as well as Mars robotic missions, research that is conducted on the International Space Station, and future lunar exploration missions. This summary the Mars DRA 5.0 provides an overview of the overall mission approach, surface strategy and exploration goals, as well as the key systems and challenges for the first three human missions to Mars.
2001-03-01
between attacks and other events such as accidents, system failures, or hacking by thrill-seekers. This challenge is exacerbated by the speed of events in...International Telegraph and Telephone (CCITT) international standards body and is referred to as Signaling System # 7 ( SS7 ). Commerc" I Intelligent...point to fixed infrastructure "" Signaling Transfer Point (STP) - Packet switch in CCITT#7 Network STP ... SS7 * System Data Bases i Network
32 CFR Appendix A to Part 513 - References
Code of Federal Regulations, 2013 CFR
2013-07-01
... Records from Army Files. (Cited in § 513.2(a)(3)(viii)(H)). AR 340-18 The Army Functional Files System... regulation. AR 1-9 White House Liaison, Communications, and Inspections. AR 11-2 Internal Control Systems. AR...
32 CFR Appendix A to Part 513 - References
Code of Federal Regulations, 2012 CFR
2012-07-01
... Records from Army Files. (Cited in § 513.2(a)(3)(viii)(H)). AR 340-18 The Army Functional Files System... regulation. AR 1-9 White House Liaison, Communications, and Inspections. AR 11-2 Internal Control Systems. AR...
32 CFR Appendix A to Part 513 - References
Code of Federal Regulations, 2011 CFR
2011-07-01
... Records from Army Files. (Cited in § 513.2(a)(3)(viii)(H)). AR 340-18 The Army Functional Files System... regulation. AR 1-9 White House Liaison, Communications, and Inspections. AR 11-2 Internal Control Systems. AR...
International Organisations and the Evaluation of Education Systems: A Critical Comparative Analysis
ERIC Educational Resources Information Center
Neves, Claudia
2008-01-01
This article seeks to develop research involving a macro-level critical comparative analysis of reference documents produced by international organisations (UNDP, OECD, UNESCO, the World Bank and the European Union) which guide world education policy decisions. The primary objective was to consider the key guidelines currently defined for…
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Definitions. 733.101 Section 733.101 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT GENERAL CONTRACTING REQUIREMENTS PROTESTS, DISPUTES, AND APPEALS Protests 733.101 Definitions. (a) All “days” referred...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Definitions. 733.101 Section 733.101 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT GENERAL CONTRACTING REQUIREMENTS PROTESTS, DISPUTES, AND APPEALS Protests 733.101 Definitions. (a) All “days” referred...
1998-07-01
Intermediate Care Facility ICN Internal Control Number ICU Intensive Care Unit Desk Reference 59 ID Identification IDC Independent Duty Corpsman IDFN... Intermediate Care Facility -- A less expensive healthcare setting for patients who are not in need of acute or skilled nursing care but yet need more care
NASA Technical Reports Server (NTRS)
Jenkins, Phillip; Scheiman, Chris; Goodbody, Chris; Baur, Carsten; Sharps, Paul; Imaizumi, Mitsuru; Yoo, Henry; Sahlstrom, Ted; Walters, Robert; Lorentzen, Justin;
2006-01-01
This paper reports the results of an international measurement round robin of monolithic, triple-junction, GaInP/GaAs/Ge space solar cells. Eight laboratories representing national labs, solar cell vendors and space solar cell consumers, measured cells using in-house reference cells and compared those results to measurements made where each lab used the same set of reference cells. The results show that most of the discrepancy between laboratories is likely due to the quality of the standard cells rather than the measurement system or solar simulator used.
[Laboratory accreditation and proficiency testing].
Kuwa, Katsuhiko
2003-05-01
ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.
A computational procedure for multibody systems including flexible beam dynamics
NASA Technical Reports Server (NTRS)
Downer, J. D.; Park, K. C.; Chiou, J. C.
1990-01-01
A computational procedure suitable for the solution of equations of motions for flexible multibody systems has been developed. A fully nonlinear continuum approach capable of accounting for both finite rotations and large deformations has been used to model a flexible beam component. The beam kinematics are referred directly to an inertial reference frame such that the degrees of freedom embody both the rigid and flexible deformation motions. As such, the beam inertia expression is identical to that of rigid body dynamics. The nonlinear coupling between gross body motion and elastic deformation is contained in the internal force expression. Numerical solution procedures for the integration of spatial kinematic systems can be directily applied to the generalized coordinates of both the rigid and flexible components. An accurate computation of the internal force term which is invariant to rigid motions is incorporated into the general solution procedure.
OCLC: Changing the Tasks of Librarianship.
ERIC Educational Resources Information Center
Smith, K. Wayne
1993-01-01
Reviews the history of OCLC and describes current and future objectives. Highlights include membership; network affiliations; cataloging services; interlibrary loan; EPIC, a new reference system; a new telecommunications network; PRISM, a new online system for cataloging and resource sharing; pricing strategies; international operations; and…
A reference model for space data system interconnection services
NASA Astrophysics Data System (ADS)
Pietras, John; Theis, Gerhard
1993-03-01
The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).
A reference model for space data system interconnection services
NASA Technical Reports Server (NTRS)
Pietras, John; Theis, Gerhard
1993-01-01
The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).
... Direct bilirubin - urine Images Male urinary system References Berk PD, Korenblat KM. Approach to the patient with ... Review Date 5/21/2017 Updated by: Laura J. Martin, MD, MPH, ABIM Board Certified in Internal ...
On the definition and use of the ecliptic in modern astronomy
NASA Astrophysics Data System (ADS)
Capitaine, N.; Soffel, M.
2015-08-01
The ecliptic was a fundamental reference plane for astronomy from antiquity to the realization and use of the FK5 reference system. The situation has changed considerably with the adoption of the International Celestial Reference system (ICRS) by the IAU in 1998 and the IAU resolutions on reference systems that were adopted from 2000 to 2009. First, the ICRS has the property of being independent of epoch, ecliptic or equator. Second, the IAU 2000 resolutions, which specified the systems of space-time coordinates within the framework of General Relativity, for the solar system (the Barycentric Celestial Reference System, BCRS) and the Earth (the Geocentric Celestial Reference System, GCRS), did not refer to any ecliptic and did not provide a definition of a GCRS ecliptic. These resolutions also provided the definition of the pole of the nominal rotation axis (the Celestial intermediate pole, CIP) and of new origins on the equator (the Celestial and Terrestrial intermediate origins, CIO and TIO), which do not require the use of an ecliptic. Moreover, the models and standards adopted by the IAU 2006 and IAU 2009 resolutions are largely referred to the ICRS, BCRS, GCRS as well as to the new pole and origins. Therefore, the ecliptic has lost much of its importance. We review the consequences of these changes and improvements in the definition and use of the ecliptic and we discuss whether the concept of an ecliptic is still needed for some specific use in modern astronomy.
NASA Technical Reports Server (NTRS)
Sanders, B. W.
1980-01-01
The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.
On the Characteristics of Higher Education in Canada and Its Inspiration
ERIC Educational Resources Information Center
Xu, Qingyun
2009-01-01
Higher education in Canada has rich features: the unique system of educational administration and policy; the distinct features of university management model; dynamic international education; and flexible and diverse in the school system and the financing system. Drawn from the four aspects, it could be used for reference in China's higher…
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
NASA Astrophysics Data System (ADS)
Ma, Chopo; MacMillan, Daniel; Gordon, David
2015-08-01
The Second Realization of the International Celestial Reference Frame (ICRF) used dual-frequency VLBI data acquired for geodetic and astrometric purposes from 1979-2009 by organizations now coordinated by the International VLBI Service for Geodesy and Astrometry (IVS) and analyzed according to the Conventions of the International Earth Rotation and Reference Systems Service (IERS). Since 2009 the data set has been significantly broadened, especially by observations in the Southern Hemisphere, and modeling of astronomical, geophysical and tropospheric effects has progressed. The new southern data appear to cause a systematic zonal declination change in the catalog positions. Over the three decades of the ICRF data set the effect of galactic aberration may be significant. Geophysical and tropospheric models also may affect the source positions. All these effects need to be addressed in preparation for ICRF-3.
On the establishment and maintenance of a modern conventional terrestrial reference system
NASA Technical Reports Server (NTRS)
Bock, Y.; Zhu, S. Y.
1982-01-01
The frame of the Conventional Terrestrial Reference System (CTS) is defined by an adopted set of coordinates, at a fundamental epoxh, of a global network of stations which contribute the vertices of a fundamental polyhedron. A method to estimate this set of coordinates using a combination of modern three dimensional geodetic systems is presented. Once established, the function of the CTS is twofold. The first is to monitor the external (or global) motions of the polyhedron with respect to the frame of a Conventional Inertial Reference System, i.e., those motions common to all stations. The second is to monitor the internal motions (or deformations) of the polyhedron, i.e., those motions that are not common to all stations. Two possible estimators for use in earth deformation analysis are given and their statistical and physical properties are described.
NASA Astrophysics Data System (ADS)
Liu, J.-C.; Malkin, Z.; Zhu, Z.
2018-03-01
The International Celestial Reference Frame (ICRF) is currently realized by the very long baseline interferometry (VLBI) observations of extragalactic sources with the zero proper motion assumption, while Gaia will observe proper motions of these distant and faint objects to an accuracy of tens of microarcseconds per year. This paper investigates the difference between VLBI and Gaia quasar proper motions and it aims to understand the impact of quasar proper motions on the alignment of the ICRF and Gaia reference frame. We use the latest time series data of source coordinates from the International VLBI Service analysis centres operated at Goddard Space Flight Center (GSF2017) and Paris observatory (OPA2017), as well as the Gaia auxiliary quasar solution containing 2191 high-probability optical counterparts of the ICRF2 sources. The linear proper motions in right ascension and declination of VLBI sources are derived by least-squares fits while the proper motions for Gaia sources are simulated taking into account the acceleration of the Solar system barycentre and realistic uncertainties depending on the source brightness. The individual and global features of source proper motions in GSF2017 and OPA2017 VLBI data are found to be inconsistent, which may result from differences in VLBI observations, data reduction and analysis. A comparison of the VLBI and Gaia proper motions shows that the accuracies of the components of rotation and glide between the two systems are 2-4 μas yr- 1 based on about 600 common sources. For the future alignment of the ICRF and Gaia reference frames at different wavelengths, the proper motions of quasars must necessarily be considered.
Andrade, Vera Lúcia Fonseca; Fernandes, Filipa Alexandra Veludo
2016-01-01
to describe strategies used by health professionals on the implementation of the Centers for Disease Control and Prevention guidelines for the prevention of urinary infection related to catheterism. systematic review on literature based on data from CINAHL(r), Nursing & Allied Health Collection, Cochrane Plus Collection, MedicLatina, MEDLINE(r), Academic Search Complete, ACS - American Chemical Society, Health Reference Center Academic, Nursing Reference Center, ScienceDirect Journals and Wiley Online Library. A sample of 13 articles was selected. studies have highlighted the decrease of urinary tract infection related to catheterism through reminder systems to decrease of people submitted to urinary catheterism, audits about nursing professionals practice and bundles expansion. the present review systemizes the knowledge of used strategies by health professionals on introduction to international recommendations, describing a rate decrease of such infection in clinical practice.
A Structured Approach for Reviewing Architecture Documentation
2009-12-01
as those found in ISO 12207 [ ISO /IEC 12207 :2008] (for software engineering), ISO 15288 [ ISO /IEC 15288:2008] (for systems engineering), the Rational...Open Distributed Processing - Reference Model: Foundations ( ISO /IEC 10746-2). 1996. [ ISO /IEC 12207 :2008] International Organization for...Standardization & International Electrotechnical Commission. Sys- tems and software engineering – Software life cycle processes ( ISO /IEC 12207 ). 2008. [ ISO
Rigger, Romana; Rück, Alexander; Hellriegel, Christine; Sauermoser, Robert; Morf, Fabienne; Breitruck, KathrinBreitruck; Obkircher, Markus
2017-09-01
In recent years, quantitative NMR (qNMR) spectroscopy has become one of the most important tools for content determination of organic substances and quantitative evaluation of impurities. Using Certified Reference Materials (CRMs) as internal or external standards, the extensively used qNMR method can be applied for purity determination, including unbroken traceability to the International System of Units (SI). The implementation of qNMR toward new application fields, e.g., metabolomics, environmental analysis, and physiological pathway studies, brings along more complex molecules and systems, thus making use of 1H qNMR challenging. A smart workaround is possible by the use of other NMR active nuclei, namely 31P and 19F. This article presents the development of three classes of qNMR CRMs based on different NMR active nuclei (1H, 31P, and 19F), and the corresponding approaches to establish traceability to the SI through primary CRMs from the National Institute of Standards and Technology and the National Metrology Institute of Japan. These TraceCERT® qNMR CRMs are produced under ISO/IEC 17025 and ISO Guide 34 using high-performance qNMR.
Bas Mor, H; Altinsoy, N; Söyler, I
2018-05-08
The aim of this study was to evaluate the radiation doses to patient during chest (posterior anterior/and lateral) examinations. The study was performed in three public hospitals of İstanbul province with a total of 300 adult patients. Entrance surface dose (ESD) measurements were conducted on computed radiography, digital radiography and screen film system. ESD was estimated by using International Atomic Energy Agency (IAEA) model and Davies model which are the common indirect models. Results were compared with diagnostic reference levels from the European Commission, IAEA and National Radiological Protection Board. Although the results are compatible with the international diagnostic reference levels, they present variations between the hospitals. Dose variations for the same type of X-ray examination support the idea that further optimization is possible.
46 CFR 34.01-15 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Systems, IBR approved for § 34.30-1 (“NFPA 13-1996”). (2) NFPA 2001, Standard on Clean Agent Fire... Headquarters. Contact Commandant (CG-ENG), Attn: Office of Design and Engineering Systems, U.S. Coast Guard... F1121-87 (Reapproved 2010), Standard Specification for International Shore Connections for Marine Fire...
46 CFR 34.01-15 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Systems, IBR approved for § 34.30-1 (“NFPA 13-1996”). (2) NFPA 2001, Standard on Clean Agent Fire... Headquarters. Contact Commandant (CG-ENG), Attn: Office of Design and Engineering Systems, U.S. Coast Guard... F1121-87 (Reapproved 2010), Standard Specification for International Shore Connections for Marine Fire...
Asian Higher Education: An International Handbook and Reference Guide.
ERIC Educational Resources Information Center
Postiglione, Gerard A., Ed.; Mak, Grace C., Ed.
This book is a guide to the present academic systems of twenty Asian countries and political units. Data provided in each chapter include a historical overview, description of the current system, funding support, enrollment rates, and overall organization of higher education. The chapters include: (1) "Bangladesh" (Kowsar P. Chowdhury);…
NASA Astrophysics Data System (ADS)
Wang, Qianxin; Hu, Chao; Xu, Tianhe; Chang, Guobin; Hernández Moraleda, Alberto
2017-12-01
Analysis centers (ACs) for global navigation satellite systems (GNSSs) cannot accurately obtain real-time Earth rotation parameters (ERPs). Thus, the prediction of ultra-rapid orbits in the international terrestrial reference system (ITRS) has to utilize the predicted ERPs issued by the International Earth Rotation and Reference Systems Service (IERS) or the International GNSS Service (IGS). In this study, the accuracy of ERPs predicted by IERS and IGS is analyzed. The error of the ERPs predicted for one day can reach 0.15 mas and 0.053 ms in polar motion and UT1-UTC direction, respectively. Then, the impact of ERP errors on ultra-rapid orbit prediction by GNSS is studied. The methods for orbit integration and frame transformation in orbit prediction with introduced ERP errors dominate the accuracy of the predicted orbit. Experimental results show that the transformation from the geocentric celestial references system (GCRS) to ITRS exerts the strongest effect on the accuracy of the predicted ultra-rapid orbit. To obtain the most accurate predicted ultra-rapid orbit, a corresponding real-time orbit correction method is developed. First, orbits without ERP-related errors are predicted on the basis of ITRS observed part of ultra-rapid orbit for use as reference. Then, the corresponding predicted orbit is transformed from GCRS to ITRS to adjust for the predicted ERPs. Finally, the corrected ERPs with error slopes are re-introduced to correct the predicted orbit in ITRS. To validate the proposed method, three experimental schemes are designed: function extrapolation, simulation experiments, and experiments with predicted ultra-rapid orbits and international GNSS Monitoring and Assessment System (iGMAS) products. Experimental results show that using the proposed correction method with IERS products considerably improved the accuracy of ultra-rapid orbit prediction (except the geosynchronous BeiDou orbits). The accuracy of orbit prediction is enhanced by at least 50% (error related to ERP) when a highly accurate observed orbit is used with the correction method. For iGMAS-predicted orbits, the accuracy improvement ranges from 8.5% for the inclined BeiDou orbits to 17.99% for the GPS orbits. This demonstrates that the correction method proposed by this study can optimize the ultra-rapid orbit prediction.
Boomsma, Martijn F; Slouwerhof, Inge; van Dalen, Jorn A; Edens, Mireille A; Mueller, Dirk; Milles, Julien; Maas, Mario
2015-11-01
The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue.
SIRGAS: the core geodetic infrastructure in Latin America and the Caribbean
NASA Astrophysics Data System (ADS)
Sanchez, L.; Brunini, C.; Drewes, H.; Mackern, V.; da Silva, A.
2013-05-01
Studying, understanding, and modelling geophysical phenomena, such as global change and geodynamics, require geodetic reference frames with (1) an order of accuracy higher than the magnitude of the effects we want to study, (2) consistency and reliability worldwide (the same accuracy everywhere), and (3) a long-term stability (the same order of accuracy at any time). The definition, realisation, maintenance, and wide-utilisation of the International Terrestrial Reference System (ITRS) are oriented to guarantee a globally unified geometric reference frame with reliability at the mm-level, i.e. the International Terrestrial Reference Frame (ITRF). The densification of the global ITRF in Latin America and The Caribbean is given by SIRGAS (Sistema de Referencia Geocéntrico para Las Américas), primary objective of which is to provide the most precise coordinates in the region. Therefore, SIRGAS is the backbone for all regional projects based on the generation, use, and analysis of geo-referenced data at national as well as at international level. Besides providing the reference for a wide range of scientific applications such as the monitoring of Earth's crust deformations, vertical movements, sea level variations, atmospheric studies, etc., SIRGAS is also the platform for practical applications such as engineering projects, digital administration of geographical data, geospatial data infrastructures, etc. According to this, the present contribution describes the main features of SIRGAS, giving special care to those challenges faced to continue providing the best possible, long-term stable and high-precise reference frame for Latin America and the Caribbean.
Zhang, Zhen; Yan, Peng; Jiang, Huan; Ye, Peiqing
2014-09-01
In this paper, we consider the discrete time-varying internal model-based control design for high precision tracking of complicated reference trajectories generated by time-varying systems. Based on a novel parallel time-varying internal model structure, asymptotic tracking conditions for the design of internal model units are developed, and a low order robust time-varying stabilizer is further synthesized. In a discrete time setting, the high precision tracking control architecture is deployed on a Voice Coil Motor (VCM) actuated servo gantry system, where numerical simulations and real time experimental results are provided, achieving the tracking errors around 3.5‰ for frequency-varying signals. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
42 CFR 424.507 - Ordering and referring covered items and services for Medicare beneficiaries.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ordered or referred by a resident or an intern, the claim must identify the teaching physician as the... referred by a resident or an intern, the claim must identify the teaching physician as the ordering or... intern, the claim must identify the teaching physician as the ordering or referring physician. The claim...
42 CFR 424.507 - Ordering and referring covered items and services for Medicare beneficiaries.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ordered or referred by a resident or an intern, the claim must identify the teaching physician as the... referred by a resident or an intern, the claim must identify the teaching physician as the ordering or... intern, the claim must identify the teaching physician as the ordering or referring physician. The claim...
How Should Blood Glucose Meter System Analytical Performance Be Assessed?
Simmons, David A
2015-08-31
Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.
Observations on the NHS internal market: will the dodo get the last laugh?
Royce, R. G.
1995-01-01
Distinguishing between the theory and practice of the internal market has been obscured by the considerable controversy generated by the reforms themselves. In such an environment both the advocates and the opponents of a market based solution have tended to promote their respective claims by reference to underlying political philosophies and economic theories rather than practical experience. Royce gives his observations of the actual operation of the internal market with particular reference to the commissioning function in Wales. He highlights inadequacies and inequities in the current system and proposes some remedial actions. Central to these are the importance of ensuring equitable funding for all purchasers, acknowledging the necessity of rationing, and promoting efficient and effective health care, sometimes at the expense of patient choice and guaranteed local service provision. Images p432-a PMID:7640593
The Third International Reference Preparation of Egg Lecithin
Krag, P.; Bentzon, M. Weis
1961-01-01
The Third International Reference Preparation of Egg Lecithin was produced (in a quantity of 5000 ml) at the WHO Serological Reference Centre, Copenhagen, and assayed in 1958 against the Second International Reference Preparation by four laboratories in three countries. Complement-fixation and slide-flocculation tests were used. The new preparation was found acceptable, and its establishment was authorized by the WHO Expert Committee on Biological Standardization. The average log10 titres and results of analyses of variances are shown. The variances were of the usual order of magnitude, and the differences in titre between antigens containing the Second and the Third International Reference Preparations varied from -0.011 to 0.116; only one of the differences exceeded the 5% limit of significance. The use of the Third International Reference Preparation in tests for the acceptability of lecithin preparations is described. PMID:13753864
ERIC Educational Resources Information Center
Sancho Gargallo, Miguel Angel
2013-01-01
As governments strive to improve outcomes in education, and respond to the needs of an ever more diverse population, autonomy has gained increased prominence in national and international spheres. In the context of education, autonomy refers to the decision-making capacity of a school, and to the manner and areas over which those decisions can be…
1987-01-01
Scientific symposia on haemoglobinometry were held at the 9th Congress of the European Society of Haematology, Lisbon, 1963 (ESH 1964) and the 10th Congress of the International Society of Haematology (ISH), Stockholm, 1964 (ISH 1965). The International Committee for Standardization in Haematology (ICSH) made recommendations endorsed by the General Assembly of ICSH in Sydney on 23 August 1966 (ICSH 1967), for a reference method for haemoglobinometry and for the manufacture and distribution of an international reference preparation. Further symposia were held at the 12th Congress of the ISH, New York, 1968 (Astaldi, Sirtori & Vanzetti 1979) and at the 13th Congress of ISH, Munich, 1970 (Izak & Lewis 1972). The recommendations were reissued in 1978 (ISH 1978). On the basis of continuing experimental studies, the reference method and the specifications for the international reference preparation have been modified. The revised recommendations are described in this document.
46 CFR 56.07-10 - Design conditions and criteria (modifies 101-104.7).
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENGINEERING PIPING SYSTEMS AND APPURTENANCES Design § 56.07-10 Design conditions and criteria (modifies 101... system must not be greater than the internal design pressure defined in 104.1.2 of ASME B31.1 (incorporated by reference; see 46 CFR 56.01-2). (2) Where the maximum allowable working pressure of a system...
The AuScope geodetic VLBI array
NASA Astrophysics Data System (ADS)
Lovell, J. E. J.; McCallum, J. N.; Reid, P. B.; McCulloch, P. M.; Baynes, B. E.; Dickey, J. M.; Shabala, S. S.; Watson, C. S.; Titov, O.; Ruddick, R.; Twilley, R.; Reynolds, C.; Tingay, S. J.; Shield, P.; Adada, R.; Ellingsen, S. P.; Morgan, J. S.; Bignall, H. E.
2013-06-01
The AuScope geodetic Very Long Baseline Interferometry array consists of three new 12-m radio telescopes and a correlation facility in Australia. The telescopes at Hobart (Tasmania), Katherine (Northern Territory) and Yarragadee (Western Australia) are co-located with other space geodetic techniques including Global Navigation Satellite Systems (GNSS) and gravity infrastructure, and in the case of Yarragadee, satellite laser ranging (SLR) and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) facilities. The correlation facility is based in Perth (Western Australia). This new facility will make significant contributions to improving the densification of the International Celestial Reference Frame in the Southern Hemisphere, and subsequently enhance the International Terrestrial Reference Frame through the ability to detect and mitigate systematic error. This, combined with the simultaneous densification of the GNSS network across Australia, will enable the improved measurement of intraplate deformation across the Australian tectonic plate. In this paper, we present a description of this new infrastructure and present some initial results, including telescope performance measurements and positions of the telescopes in the International Terrestrial Reference Frame. We show that this array is already capable of achieving centimetre precision over typical long-baselines and that network and reference source systematic effects must be further improved to reach the ambitious goals of VLBI2010.
26 CFR 49.4253-12 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 49.4253-12 Section 49.4253-12 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES FACILITIES AND SERVICES EXCISE TAXES Communications § 49.4253-12 Cross reference. For exemptions...
26 CFR 44.4906-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 44.4906-1 Section 44.4906-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE... Taxes on Wagering General Provisions Relating to Occupational Taxes § 44.4906-1 Cross reference. For...
26 CFR 1.162-16 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Cross reference. 1.162-16 Section 1.162-16 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.162-16 Cross reference...
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
The African Reference Frame (AFREF) project: a fundamental geodetic tool for Africa
NASA Astrophysics Data System (ADS)
Farah, H.
2009-04-01
AFREF has as objective the establishment and maintenance of a unified geodetic reference frame for Africa, which will support and facilitate fundamental scientific and technical projects. The installation of observation systems all over Africa will provide important data that can be used in many different scientific fields (e.g., geodynamics, meteorological). Furthermore, AFREF will create an uniform frame that will support development projects, uniform environmental and mapping programmes as well as aid in resolving current and future international boundary disputes. This reference frame will be based on the International Terrestrial Reference Frame (ITRF) and will be realised through the establishment of a network of permanent Global Navigation Satellite System (GNSS) receivers. In close collaboration with several institutional role players, AFREF is an initiative of the United Nations Economic Commission for Africa (UNECA) Committee on Development Information (CODI). A steering committee is currently responsible for the over-all management and coordination of the implementation of AFREF. Implementation of AFREF is envisaged to be at national level in collaboration with National Mapping Organizations. Furthermore, many scientific Institutions are contributing for the densification of the network. The current status of the AFREF network will be discussed in detail. Several CORS systems have been installed to support AFREF specifically. In addition, most or all of the IGS stations located in Africa will automatically qualify as AFREF core stations. Furthermore, we will show examples of interaction between specific projects and AFREF that are contributing for the development of science in Africa.
26 CFR 1.503(d)-1 - Cross references.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Cross references. 1.503(d)-1 Section 1.503(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Exempt Organizations § 1.503(d)-1 Cross references. For provisions relating to...
26 CFR 1.811-3 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.811-3 Section 1.811-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Gain and Loss from Operations § 1.811-3 Cross-reference. For special rules regarding the...
26 CFR 301.9001-3 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Cross reference. 301.9001-3 Section 301.9001-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND... reference. See the Coast Guard regulations under 33 CFR parts 135 and 136 for rules relating to the...
26 CFR 1.812-9 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.812-9 Section 1.812-9 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Gain and Loss from Operations § 1.812-9 Cross-reference. For special rules regarding the...
26 CFR 1.807-2 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.807-2 Section 1.807-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Investment Income § 1.807-2 Cross-reference. For special rules regarding the treatment of...
26 CFR 1.681(b)-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross reference. 1.681(b)-1 Section 1.681(b)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Miscellaneous § 1.681(b)-1 Cross reference. For disallowance of certain charitable, etc...
Ranyard, R; Charlton, J P; Williamson, J
2001-02-01
Alternative reference prices, either displayed in the environment (external) or recalled from memory (internal) are known to influence consumer judgments and decisions. In one line of previous research, internal reference prices have been defined in terms of general price expectations. However, Thaler (Marketing Science 4 (1985) 199; Journal of Behavioral Decision Making 12 (1999) 183) defined them as fair prices expected from specific types of seller. Using a Beer Pricing Task, he found that seller context had a substantial effect on willingness to pay, and concluded that this was due to specific internal reference prices evoked by specific contexts. In a think aloud study using the same task (N = 48), we found only a marginal effect of seller context. In a second study using the Beer Pricing Task and seven analogous ones (N = 144), general internal reference prices were estimated by asking people what they normally paid for various commodities. Both general internal reference prices and seller context influenced willingness to pay, although the effect of the latter was again rather small. We conclude that general internal reference prices have a greater impact in these scenarios than specific ones, because of the lower cognitive load involved in their storage and retrieval.
OSI Conformance Testing for Bibliographic Applications.
ERIC Educational Resources Information Center
Arbez, Gilbert; Swain, Leigh
1990-01-01
Describes the development of Open Systems Interconnection (OSI) conformance testing sites, conformance testing tools, and conformance testing services. Discusses related topics such as interoperability testing, arbitration testing, and international harmonization of conformance testing. A glossary is included. (24 references) (SD)
Annual Review of Database Development: 1992.
ERIC Educational Resources Information Center
Basch, Reva
1992-01-01
Reviews recent trends in databases and online systems. Topics discussed include new access points for established databases; acquisitions, consolidations, and competition between vendors; European coverage; international services; online reference materials, including telephone directories; political and legal materials and public records;…
The International Gravity Field Service (IGFS): Present Day Activities And Future Plans
NASA Astrophysics Data System (ADS)
Barzaghi, R.; Vergos, G. S.
2016-12-01
IGFS is a unified "umbrella" IAG service that coordinates the servicing of the geodetic and geophysical community with gravity field related data, software and information. The combined data of the IGFS entities will include global geopotential models, terrestrial, airborne, satellite and marine gravity observations, Earth tide data, GPS/levelling data, digital models of terrain and bathymetry, as well as ocean gravity field and geoid from satellite altimetry. The IGFS structure is based on the Gravity Services, the "operating arms" of IGFS. These Services related to IGFS are: BGI (Bureau Gravimetrique International), Toulouse, France ISG (International Service for the Geoid), Politecnico di Milano, Milano, Italy IGETS (International Geodynamics and Earth Tides Service), EOST, Strasbourg, France ICGEM (International Center for Global Earth Models), GFZ, Potsdam, Germany IDEMS (International Digital Elevation Model Service), ESRI, Redlands, CA, USA The Central Bureau, hosted at the Aristotle Thessaloniki University, is in charge for all the interactions among the services and the other IAG bodies, particularly GGOS. In this respect, connections with the GGOS Bureaus of Products and Standards and of Networks and Observations have been recently strengthened in order to align the Gravity services to the GGOS standards. IGFS is also strongly involved in the most relevant projects related to the gravity field such as the establishment of the new Global Absolute Gravity Reference System and of the International Height Reference System. These projects, along with the organization of Geoid Schools devoted to methods for gravity and geoid estimate, will play a central role in the IGFS future actions in the framework of GGOS.
USSR and Eastern Europe Scientific Abstracts, Engineering and Equipment, Number 32
1977-05-25
serial publication contains abstracts of articles and news items from USSR and Eastern Europe scientific and technical journals on the specific...loads ( internal pressure plus pure bending). A study is made of a broad range of problems involved in the design of torroidal, spherical and...and protec- tion system are regulated by the International Electrical Engineering Com- mission. Figure 1; tables 2; references 12. 18 Construction
Certification of reference materials for the determination of alkylphenols.
Hanari, Nobuyasu; Ishikawa, Keiichiro; Shimizu, Yoshitaka; Otsuka, Satoko; Iwasawa, Ryoko; Fujiki, Naomi; Numata, Masahiko; Yarita, Takashi; Kato, Kenji
2015-04-01
Certified reference materials (CRMs) are playing an increasingly important role in national and international standardizing activities. In Japan, primary standard solutions for analyses of endocrine disrupters are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). For the traceability on reference materials used for preparation of the primary standard solutions based on the JCSS, the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed and certified high-purity reference materials of alkylphenols as NMIJ CRMs, such as 4-n-nonylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-tert-butylphenol, and 2,4-dichlorophenol. Thereafter, it is essential to determine the alkylphenols by using these solutions based on the JCSS for environmental monitoring and risk assessments because analytical values obtained by using the solutions can ensure the reliability and traceability of the chemical analyses.
26 CFR 1.691(f)-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross reference. 1.691(f)-1 Section 1.691(f)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Income in Respect of Decedents § 1.691(f)-1 Cross reference. See section 753 and the...
ERIC Educational Resources Information Center
Heller, Stephen R.; And Others
1973-01-01
A prototype of an interactive, conversational mass spectral search system, developed at the National Institutes of Health, has been tested since September 1971 and is now being used by more than 200 scientists in the U.S. and Canada, and will soon be used by the international mass spectrometry community. (17 references) (SJ)
NASA Technical Reports Server (NTRS)
King, M. D. (Editor); Greenstone, R. (Editor)
2000-01-01
The content of this handbook includes Earth Science Enterprise; The Earth Observing System; EOS Data and Information System (EOSDIS); Data and Information Policy; Pathfinder Data Sets; Earth Science Information Partners and the Working Prototype-Federation; EOS Data Quality: Calibration and Validation; Education Programs; International Cooperation; Interagency Coordination; Mission Elements; EOS Instruments; EOS Interdisciplinary Science Investigations; and Points-of-Contact.
Satellite Power System (SPS) military implications
NASA Technical Reports Server (NTRS)
Bain, C. N.
1978-01-01
The military implications of the reference satellite power system (SPS) were examined is well as important military related study tasks. Primary areas of investigation were the potential of the SPS as a weapon, for supporting U.S. military preparedness, and for affecting international relations. In addition, the SPS's relative vulnerability to overt military action, terrorist attacks, and sabotage was considered.
International review of cytology. Volume 106. A survey of cell biology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bourne, G.H.; Jeon, K.W.; Friedlander, M.
1987-01-01
Contents: Morphology and Cytochemistry of the Endocrine Epthelial System in the Lung; Intrinsic Nerve Plexus of Mammalian Heart; Morphological Basis of Cardiac Rhythmical Activity. Structural and Functional Evolution of Gonadotropin-Releasing Hormone; Excitons and Solitons in Molecular Systems; The Centrosome and Its Role in the Organization of Microtubules. Each chapter includes references. Index.
ERIC Educational Resources Information Center
Winton, Harry N. M., Comp.
Publication of the international agencies of the United Nations system, thru 1971, that refer to man, world natural resources, the environment and population trends are arranged according to subject matter. Within most categories, entries are arranged by geographical area. Descriptive annotations are provided for each of the more than 1200…
46 CFR 34.01-15 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for the Installation of Sprinkler Systems, IBR approved for § 34.30-1 (“NFPA 13-1996”). (2) NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems, (2008 Edition), IBR approved for § 34.05-5(a)(4) (“NFPA... Specification for International Shore Connections for Marine Fire Applications, 1987, IBR approved for § 34.10...
32 CFR Appendix A to Part 584 - Reference
Code of Federal Regulations, 2011 CFR
2011-07-01
... Certain Other Units of the Army. AR 340-18 The Army Functional Files System AR 600-240 Marriage in Oversea...-17 Release of Information and Records from Army Files. (Cited in § 584.1(f)(2).) AR 340-21 The Army... regulation. AR 11-2 Internal Control Systems AR 20-1 Inspector General Activities and Procedures AR 140-1...
32 CFR Appendix A to Part 584 - Reference
Code of Federal Regulations, 2013 CFR
2013-07-01
... Certain Other Units of the Army. AR 340-18 The Army Functional Files System AR 600-240 Marriage in Oversea...-17 Release of Information and Records from Army Files. (Cited in § 584.1(f)(2).) AR 340-21 The Army... regulation. AR 11-2 Internal Control Systems AR 20-1 Inspector General Activities and Procedures AR 140-1...
32 CFR Appendix A to Part 584 - Reference
Code of Federal Regulations, 2012 CFR
2012-07-01
... Certain Other Units of the Army. AR 340-18 The Army Functional Files System AR 600-240 Marriage in Oversea...-17 Release of Information and Records from Army Files. (Cited in § 584.1(f)(2).) AR 340-21 The Army... regulation. AR 11-2 Internal Control Systems AR 20-1 Inspector General Activities and Procedures AR 140-1...
32 CFR Appendix A to Part 584 - Reference
Code of Federal Regulations, 2014 CFR
2014-07-01
... Certain Other Units of the Army. AR 340-18 The Army Functional Files System AR 600-240 Marriage in Oversea...-17 Release of Information and Records from Army Files. (Cited in § 584.1(f)(2).) AR 340-21 The Army... regulation. AR 11-2 Internal Control Systems AR 20-1 Inspector General Activities and Procedures AR 140-1...
Archival Services and the Concept of the User: A RAMP Study.
ERIC Educational Resources Information Center
Taylor, Hugh A.
Prepared under contract with the International Council on Archives (ICA), this study is intended to assist archivists and information specialists in creating, developing, and evaluating modern archival systems and services, particularly with reference to the concept and the role of the user in such systems and services. It ranges over a wide field…
Watershed Education for Sustainable Development.
ERIC Educational Resources Information Center
Stapp, William B.
2000-01-01
Presents information on the Global Rivers Environmental Education Network (GREEN), which is a global communication system for analyzing watershed usage and monitoring the quality and quantity of river water. Describes GREEN's watershed educational model and strategies and international development. (Contains 67 references.) (Author/YDS)
Management: A continuing literature survey with indexes, March 1976
NASA Technical Reports Server (NTRS)
1976-01-01
Management is a compilation of references to selected reports, journal articles, and other documents on the subject of management. This publication lists 368 documents originally announced in the 1975 issues of Scientific and Technical Aerospace Reports (STAR) or International Aerospace Abstracts (IAA). It includes references on the management of research and development, contracts, production, logistics, personnel, safety, reliability and quality control. It also includes references on: program, project and systems management; management policy, philosophy, tools, and techniques; decisionmaking processes for managers; technology assessment; management of urban problems; and information for managers on Federal resources, expenditures, financing, and budgeting.
Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B
1999-01-01
An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.
İnal, Tolga; Ataç, Gökçe
2014-01-01
We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.
41 CFR 302-17.13 - Source references.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 4 2010-07-01 2010-07-01 false Source references. 302... references. The following references or publications have been used as source material for this part. (a...) Internal Revenue Service Publication 521, “Moving Expenses.” (c) Internal Revenue Service, Circular E...
26 CFR 1.642(a)(3)-3 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross reference. 1.642(a)(3)-3 Section 1.642(a)(3)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Estates, Trusts, and Beneficiaries § 1.642(a)(3)-3 Cross reference. See § 1.683-2(c...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2014 CFR
2014-07-01
... Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) OIL AND GAS EXTRACTION POINT...—Reference C16-C18 Internal Olefin Drilling Fluid Formulation The reference C16-C18 internal olefin drilling...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2012 CFR
2012-07-01
... Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) OIL AND GAS EXTRACTION POINT...—Reference C16-C18 Internal Olefin Drilling Fluid Formulation The reference C16-C18 internal olefin drilling...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2013 CFR
2013-07-01
... Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) OIL AND GAS EXTRACTION POINT...—Reference C16-C18 Internal Olefin Drilling Fluid Formulation The reference C16-C18 internal olefin drilling...
Kêkê, L M; Samouda, H; Jacobs, J; di Pompeo, C; Lemdani, M; Hubert, H; Zitouni, D; Guinhouya, B C
2015-06-01
This study aims to compare three body mass index (BMI)-based classification systems of childhood obesity: the French, the International Obesity Task Force (IOTF) and the World Health Organization (WHO) references. The study involved 1382 schoolchildren, recruited from the Lille Academic District in France in May 2009 aged 8.4±1.7 years (4.0-12.0 years). Their mean height and body mass were 131.5±10.9cm and 30.7±9.2kg, respectively, resulting in a BMI of 17.4±3.2kg/m(2). The weight status was defined according to the three systems considered in this study. The agreement between these references was tested using the Cohen's kappa coefficient. The prevalence of overweight was higher with the WHO references (20.0%) in comparison with the French references (13.8%; P<0.0001) and the IOTF (16.2%; P≤0.01). A similar result was found with obesity (WHO: 11.6% vs. IOTF: 6.7%; or French references: 6.7%; P<0.0001). Agreement between the three references ranged from "moderate" to "perfect" (0.43≤κ≤1.00; P<0.0001). Kappa coefficients were higher when the three references were used to classify children as obese (0.63≤κ≤1.00; P<0.0001) as compared to classification in the overweight (obesity excluded) category (0.43≤κ≤0.94; P<0.0001). When sex and age categories (4-6 years vs. 7-12 years) were considered to define the overweight status, the lowest kappa coefficient was found between the French and WHO references in boys aged 7-12 years (κ=0.28; P<0.0001), and the highest one in girls aged 7-12 years between the French references and IOTF (κ=0.97; P<0.0001). As for obesity, agreement between the three references ranged from 0.60 to 1.00 (P<0.0001), with the lowest values obtained in the comparison of the WHO references against French references or IOTF among boys aged 7-12 years (κ=0.60; P<0.0001). Overall, the WHO references yield an overestimation in overweight and/or obesity within this sample of schoolchildren as compared to the French references and the IOTF. The magnitude of agreement coefficients between the three references depends on of both sex and age categories. The French references seem to be in rather close agreement with the IOTF in defining overweight, especially in 7-12-year-old children. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Baya Botti, A; Pérez-Cueto, F J A; Vasquez Monllor, P A; Kolsteren, P W
2010-01-01
Since no growth standards for adolescents exist and a single reference applicable everywhere is still in debate, it is recognized that the best reference should be derived from the growth pattern of the healthy population that will use it. In 2007 a study developed references for body mass index for 12th to 18th y Bolivian school adolescent (BAP. To compare nutritional status outcomes applying BMI references from the BAP, the Center for Disease Control and Prevention CDC 2000, the International Task Force (IOTF), and the 2007 WHO, to determine appropriateness of use in Bolivian adolescents. References were applied in 3306 adolescents, 45.0% male, 55% female, 12th to 18th y selected from a nationally representative sample. Main findings reveal that the CDC and the 2007 WHO underestimate underweight (p<0.001) and the three international references overestimate overweight (p<0.001) with variation between ages and gender. Bolivian health providers are advised to replace CDC, OITF and 2007 WHO references for the use of BAP in Bolivia which reflects its healthy adolescent population growth pattern. International references may lead to incorrect conclusions when applied on Bolivian adolescents. They could deflect efforts from population which need prompt intervention and mislead treatments and budget to unnecessary ones. We recommend validation of international references where appropriate until a standard is released.
Realizing a terrestrial reference frame using the Global Positioning System
NASA Astrophysics Data System (ADS)
Haines, Bruce J.; Bar-Sever, Yoaz E.; Bertiger, Willy I.; Desai, Shailen D.; Harvey, Nate; Sibois, Aurore E.; Weiss, Jan P.
2015-08-01
We describe a terrestrial reference frame (TRF) realization based on Global Positioning System (GPS) data alone. Our approach rests on a highly dynamic, long-arc (9 day) estimation strategy and on GPS satellite antenna calibrations derived from Gravity Recovery and Climate Experiment and TOPEX/Poseidon low Earth orbit receiver GPS data. Based on nearly 17 years of data (1997-2013), our solution for scale rate agrees with International Terrestrial Reference Frame (ITRF)2008 to 0.03 ppb yr-1, and our solution for 3-D origin rate agrees with ITRF2008 to 0.4 mm yr-1. Absolute scale differs by 1.1 ppb (7 mm at the Earth's surface) and 3-D origin by 8 mm. These differences lie within estimated error levels for the contemporary TRF.
Jiang, Lingxi; Yang, Litao; Zhang, Haibo; Guo, Jinchao; Mazzara, Marco; Van den Eede, Guy; Zhang, Dabing
2009-05-13
One rice ( Oryza sativa ) gene, sucrose phosphate synthase (SPS), has been proven to be a suitable endogenous reference gene for genetically modified (GM) rice detection in a previous study. Herein are the reported results of an international collaborative ring trial for validation of the SPS gene as an endogenous reference gene and its optimized qualitative and quantitative polymerase chain reaction (PCR) systems. A total of 12 genetically modified organism (GMO) detection laboratories from seven countries participated in the ring trial and returned their results. The validated results confirmed the species specificity of the method through testing 10 plant genomic DNAs, low heterogeneity, and a stable single-copy number of the rice SPS gene among 7 indica varieties and 5 japonica varieties. The SPS qualitative PCR assay was validated with a limit of detection (LOD) of 0.1%, which corresponded to about 230 copies of haploid rice genomic DNA, while the limit of quantification (LOQ) for the quantitative PCR system was about 23 copies of haploid rice genomic DNA, with acceptable PCR efficiency and linearity. Furthermore, the bias between the test and true values of eight blind samples ranged from 5.22 to 26.53%. Thus, we believe that the SPS gene is suitable for use as an endogenous reference gene for the identification and quantification of GM rice and its derivates.
WHO Expert Committee on Specifications for Pharmaceutical Preparations.
2014-01-01
The Expert Committee on Specifications for Pharmaceutical Preparations works towards clear, independent and practical standards and guidelines for the quality assurance of medicines. Standards are developed by the Committee through worldwide consultation and an international consensus-building process. The following new guidelines were adopted and recommended for use, in addition to 20 monographs and general texts for inclusion in The International Pharmacopoeia and 11 new International Chemical Reference Substances. The International Pharmacopoeia--updating mechanism for the section on radiopharmaceuticals; WHO good manufacturing practices for pharmaceutical products: main principles; Model quality assurance system for procurement agencies; Assessment tool based on the model quality assurance system for procurement agencies: aide-memoire for inspection; Guidelines on submission of documentation for prequalification of finished pharmaceutical products approved by stringent regulatory authorities; and Guidelines on submission of documentation for a multisource (generic) finished pharmaceutical product: quality part.
NASA Astrophysics Data System (ADS)
Kopeikin, Sergei; Xie, Yi
2010-11-01
We introduce the Jacobi coordinates adopted to the advanced theoretical analysis of the relativistic Celestial Mechanics of the Earth-Moon system. Theoretical derivation utilizes the relativistic resolutions on reference frames adopted by the International Astronomical Union (IAU) in 2000. The resolutions assume that the Solar System is isolated and space-time is asymptotically flat at infinity and the primary reference frame covers the entire space-time, has its origin at the Solar System barycenter (SSB) with spatial axes stretching up to infinity. The SSB frame is not rotating with respect to a set of distant quasars that are assumed to be at rest on the sky forming the International Celestial Reference Frame (ICRF). The second reference frame has its origin at the Earth-Moon barycenter (EMB). The EMB frame is locally inertial and is not rotating dynamically in the sense that equation of motion of a test particle moving with respect to the EMB frame, does not contain the Coriolis and centripetal forces. Two other local frames—geocentric and selenocentric—have their origins at the center of mass of Earth and Moon respectively and do not rotate dynamically. Each local frame is subject to the geodetic precession both with respect to other local frames and with respect to the ICRF because of their relative motion with respect to each other. Theoretical advantage of the dynamically non-rotating local frames is in a more simple mathematical description of the metric tensor and relative equations of motion of the Moon with respect to Earth. Each local frame can be converted to kinematically non-rotating one after alignment with the axes of ICRF by applying the matrix of the relativistic precession as recommended by the IAU resolutions. The set of one global and three local frames is introduced in order to decouple physical effects of gravity from the gauge-dependent effects in the equations of relative motion of the Moon with respect to Earth.
NASA Astrophysics Data System (ADS)
Yu, Jiang-Bo; Zhao, Yan; Wu, Yu-Qiang
2014-04-01
This article considers the global robust output regulation problem via output feedback for a class of cascaded nonlinear systems with input-to-state stable inverse dynamics. The system uncertainties depend not only on the measured output but also all the unmeasurable states. By introducing an internal model, the output regulation problem is converted into a stabilisation problem for an appropriately augmented system. The designed dynamic controller could achieve the global asymptotic tracking control for a class of time-varying reference signals for the system output while keeping all other closed-loop signals bounded. It is of interest to note that the developed control approach can be applied to the speed tracking control of the fan speed control system. The simulation results demonstrate its effectiveness.
Training survey -- educational profile for Hanford HANDI 2000 project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, D.
Fluor Daniel Hanford, Inc. (FDH) is currently adopting streamlined business processes through integrated software solutions. Replacing the legacy software (current/replacement systems, attached) also avoids significant maintenance required to resolve Year 2000 issues. This initiative is being referred to as `HANDI 2000`. The software being implemented in the first phase of this project includes Indus International`s PASSPORT Software, Peoplesoft and Primavera P3 Software. The project, which encompasses all the system replacements that will occur, has been named `HANDI 2000.` The PASSPORT applications being implemented are Inventory Management, Purchasing, Contract Management, Accounts Payable, and MSDS (Material Safety Data Sheets).
Yoshida, Mitsuru
2014-08-01
Japanese food self-sufficiency was only 39% on the basis of kcal in 2012, so Japan relies heavily on imported food. Hence the necessity of having international rules on the regulation of food contaminants is important especially for countries like Japan that depend on food imports. A One-Stop-Testing system is desired, in which the test result obtained from a single testing laboratory is accepted as valid worldwide. To establish this system, laboratory accreditation under international standards is a necessary step. Furthermore, the importance of supply of reference materials for internal quality control and proficiency testing for external quality control of each laboratory's analytical system is reviewed in connection with the experience of radioactive nuclide contamination resulting from the Fukushima nuclear power plant accident in March 2011. © 2013 Society of Chemical Industry.
Modeling of R/C Servo Motor and Application to Underactuated Mechanical Systems
NASA Astrophysics Data System (ADS)
Ishikawa, Masato; Kitayoshi, Ryohei; Wada, Takashi; Maruta, Ichiro; Sugie, Toshiharu
An R/C servo motor is a compact package of a DC geard-motor associated with a position servo controller. They are widely used in small-sized robotics and mechatronics by virtue of their compactness, easiness-to-use and high/weight ratio. However, it is crucial to clarify their internal model (including the embedded position servo) in order to improve control performance of mechatronic systems using R/C servo motors, such as biped robots or underactuted sysyems. In this paper, we propose a simple and realistic internal model of the R/C servo motors including the embedded servo controller, and estimate their physical parameters using continuous-time system identification method. We also provide a model of reference-to-torque transfer function so that we can estimate the internal torque acting on the load.
Cantilever Beam Design for Projectile Internal Moving Mass Systems
2010-09-01
instabilities. Soper (1) considered the stability of a projectile with a cylindrical mass fitted loosely within a cavity. Using a similar...oscillating beam configuration shows promise as a viable, cost-effective, reliable projectile control mechanism. 25 5. References 1. Soper , W
Design and Development of the SMAP Microwave Radiometer Electronics
NASA Technical Reports Server (NTRS)
Piepmeier, Jeffrey R.; Medeiros, James J.; Horgan, Kevin A.; Brambora, Clifford K.; Estep, Robert H.
2014-01-01
The SMAP microwave radiometer will measure land surface brightness temperature at L-band (1413 MHz) in the presence of radio frequency interference (RFI) for soil moisture remote sensing. The radiometer design was driven by the requirements to incorporate internal calibration, to operate synchronously with the SMAP radar, and to mitigate the deleterious effects of RFI. The system design includes a highly linear super-heterodyne microwave receiver with internal reference loads and noise sources for calibration and an innovative digital signal processor and detection system. The front-end comprises a coaxial cable-based feed network, with a pair of diplexers and a coupled noise source, and radiometer front-end (RFE) box. Internal calibration is provided by reference switches and a common noise source inside the RFE. The RF back-end (RBE) downconverts the 1413 MHz channel to an intermediate frequency (IF) of 120 MHz. The IF signals are then sampled and quantized by high-speed analog-to-digital converters in the radiometer digital electronics (RDE) box. The RBE local oscillator and RDE sampling clocks are phase-locked to a common reference to ensure coherency between the signals. The RDE performs additional filtering, sub-band channelization, cross-correlation for measuring third and fourth Stokes parameters, and detection and integration of the first four raw moments of the signals. These data are packetized and sent to the ground for calibration and further processing. Here we discuss the novel features of the radiometer hardware particularly those influenced by the need to mitigate RFI.
NASA Astrophysics Data System (ADS)
Moreaux, Guilhem; Lemoine, Frank G.; Capdeville, Hugues; Kuzin, Sergey; Otten, Michiel; Štěpánek, Petr; Willis, Pascal; Ferrage, Pascale
2016-12-01
In preparation of the 2014 realization of the International Terrestrial Reference Frame (ITRF2014), the International DORIS Service delivered to the International Earth Rotation and Reference Systems Service a set of 1140 weekly solution files including station coordinates and Earth orientation parameters, covering the time period from 1993.0 to 2015.0. The data come from eleven DORIS satellites: TOPEX/Poseidon, SPOT2, SPOT3, SPOT4, SPOT5, Envisat, Jason-1, Jason-2, Cryosat-2, Saral and HY-2A. In their processing, the six analysis centers which contributed to the DORIS combined solution used the latest time variable gravity models and estimated DORIS ground beacon frequency variations. Furthermore, all the analysis centers but one excepted included in their processing phase center variations for ground antennas. The main objective of this study is to present the combination process and to analyze the impact of the new modeling on the performance of the new combined solution. Comparisons with the IDS contribution to ITRF2008 show that (i) the application of the DORIS ground phase center variations in the data processing shifts the combined scale upward by nearly 7-11 mm and (ii) thanks to estimation of DORIS ground beacon frequency variations, the new combined solution no longer shows any scale discontinuity in early 2002 and does not present unexplained vertical discontinuities in any station position time series. However, analysis of the new series with respect to ITRF2008 exhibits a scale increase late 2011 which is not yet explained. A new DORIS Terrestrial Reference Frame was computed to evaluate the intrinsic quality of the new combined solution. That evaluation shows that the addition of data from the new missions equipped with the latest generation of DORIS receiver (Jason-2, Cryosat-2, HY-2A, Saral), results in an internal position consistency of 10 mm or better after mid-2008.
Xu, Xiaodan; Li, Yingcong; Zhao, Heng; Wen, Si-yuan; Wang, Sheng-qi; Huang, Jian; Huang, Kun-lun; Luo, Yun-bo
2005-05-18
To devise a rapid and reliable method for the detection and identification of genetically modified (GM) events, we developed a multiplex polymerase chain reaction (PCR) coupled with a DNA microarray system simultaneously aiming at many targets in a single reaction. The system included probes for screening gene, species reference gene, specific gene, construct-specific gene, event-specific gene, and internal and negative control genes. 18S rRNA was combined with species reference genes as internal controls to assess the efficiency of all reactions and to eliminate false negatives. Two sets of the multiplex PCR system were used to amplify four and five targets, respectively. Eight different structure genes could be detected and identified simultaneously for Roundup Ready soybean in a single microarray. The microarray specificity was validated by its ability to discriminate two GM maizes Bt176 and Bt11. The advantages of this method are its high specificity and greatly reduced false-positives and -negatives. The multiplex PCR coupled with microarray technology presented here is a rapid and reliable tool for the simultaneous detection of GM organism ingredients.
Acoustic Flow Monitor System - User Manual
LaHusen, Richard
2005-01-01
INTRODUCTION The Acoustic Flow Monitor (AFM) is a portable system that was designed by the U.S. Geological Survey Cascades Volcano Observatory to detect and monitor debris flows associated with volcanoes. It has been successfully used internationally as part of real-time warning systems in valleys threatened by such flows (Brantley, 1990; Marcial and others, 1996; Lavigne and others, 2000). The AFM system has also been proven to be an effective tool for monitoring some non-volcanic debris flows. This manual is intended to serve as a basic guide for the installation, testing, and maintenance of AFM systems. An overview of how the system works, as well as instructions for installation and guidelines for testing, is included. Interpretation of data is not covered in this manual; rather, the user should refer to the references provided for published examples of AFM data.
NASA Astrophysics Data System (ADS)
Rabah, Mostafa; Elmewafey, Mahmoud; Farahan, Magda H.
2016-06-01
A geodetic control network is the wire-frame or the skeleton on which continuous and consistent mapping, Geographic Information Systems (GIS), and surveys are based. Traditionally, geodetic control points are established as permanent physical monuments placed in the ground and precisely marked, located, and documented. With the development of satellite surveying methods and their availability and high degree of accuracy, a geodetic control network could be established by using GNSS and referred to an international terrestrial reference frame used as a three-dimensional geocentric reference system for a country. Based on this concept, in 1992, the Egypt Survey Authority (ESA) established two networks, namely High Accuracy Reference Network (HARN) and the National Agricultural Cadastral Network (NACN). To transfer the International Terrestrial Reference Frame to the HARN, the HARN was connected with four IGS stations. The processing results were 1:10,000,000 (Order A) for HARN and 1:1,000,000 (Order B) for NACN relative network accuracy standard between stations defined in ITRF1994 Epoch1996. Since 1996, ESA did not perform any updating or maintaining works for these networks. To see how non-performing maintenance degrading the values of the HARN and NACN, the available HARN and NACN stations in the Nile Delta were observed. The Processing of the tested part was done by CSRS-PPP Service based on utilizing Precise Point Positioning "PPP" and Trimble Business Center "TBC". The study shows the feasibility of Precise Point Positioning in updating the absolute positioning of the HARN network and its role in updating the reference frame (ITRF). The study also confirmed the necessity of the absent role of datum maintenance of Egypt networks.
A Survey of Technical Standards for Command and Control Information Systems
1991-09-01
H-1 Appendix I Status of Work on Lower-Layer OSI STANAGS ................ I-1 Appendix J Status of NATO OSI STANAGS ...standards efforts for use of open systems in international military systems. Thus, TSGCE SG9 draft standardization agreements ( STANAGs ), NATO...Work in NATO OSI STANAGs for the Use of Open- --- I ISystems9 References I Acronyms Index JTC: Joint Technical Committee SC: Subcommittee Figure 1
26 CFR 1.6851-3 - Furnishing of bond to insure payment; cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Furnishing of bond to insure payment; cross reference. 1.6851-3 Section 1.6851-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... Penalties § 1.6851-3 Furnishing of bond to insure payment; cross reference. See section 6863 and § 301.6863...
ERIC Educational Resources Information Center
Moller, Jens; Retelsdorf, Jan; Koller, Olaf; Marsh, Herb W.
2011-01-01
The reciprocal internal/external frame of reference model (RI/EM) combines the internal/external frame of reference model and the reciprocal effects model. The RI/EM predicts positive effects of mathematics and verbal achievement and academic self-concepts (ASC) on subsequent mathematics and verbal achievements and ASCs within domains and negative…
Bailey, Timothy S; Klaff, Leslie J; Wallace, Jane F; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A
2016-07-01
As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects' self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (-0.64% to -2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. © 2016 Diabetes Technology Society.
76 FR 50414 - International Mail Manual; Incorporation by Reference
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-15
... POSTAL SERVICE 39 CFR Part 20 International Mail Manual; Incorporation by Reference AGENCY: Postal... Standards of the United States Postal Service, International Mail Manual (IMM[supreg]) dated April 17, 2011.... SUPPLEMENTARY INFORMATION: The International Mail Manual was issued on April 17, 2011, and was updated with...
75 FR 34017 - International Mail Manual; Incorporation by Reference
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-16
... POSTAL SERVICE 39 CFR Part 20 International Mail Manual; Incorporation by Reference AGENCY: Postal... Mailing Standards of the United States Postal Service, International Mail Manual (IMM[supreg]) and its..., (202) 268-3789. SUPPLEMENTARY INFORMATION: Issue 36 of the International Mail Manual was issued on May...
Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F
2017-07-01
Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.
Wilkinson, Thomas; Sculpher, Mark J; Claxton, Karl; Revill, Paul; Briggs, Andrew; Cairns, John A; Teerawattananon, Yot; Asfaw, Elias; Lopert, Ruth; Culyer, Anthony J; Walker, Damian G
2016-12-01
Policymakers in high-, low-, and middle-income countries alike face challenging choices about resource allocation in health. Economic evaluation can be useful in providing decision makers with the best evidence of the anticipated benefits of new investments, as well as their expected opportunity costs-the benefits forgone of the options not chosen. To guide the decisions of health systems effectively, it is important that the methods of economic evaluation are founded on clear principles, are applied systematically, and are appropriate to the decision problems they seek to inform. The Bill and Melinda Gates Foundation, a major funder of economic evaluations of health technologies in low- and middle-income countries (LMICs), commissioned a "reference case" through the International Decision Support Initiative (iDSI) to guide future evaluations, and improve both the consistency and usefulness to decision makers. The iDSI Reference Case draws on previous insights from the World Health Organization, the US Panel on Cost-Effectiveness in Health Care, and the UK National Institute for Health and Care Excellence. Comprising 11 key principles, each accompanied by methodological specifications and reporting standards, the iDSI Reference Case also serves as a means of identifying priorities for methods research, and can be used as a framework for capacity building and technical assistance in LMICs. The iDSI Reference Case is an aid to thought, not a substitute for it, and should not be followed slavishly without regard to context, culture, or history. This article presents the iDSI Reference Case and discusses the rationale, approach, components, and application in LMICs. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Hanley, G. M.
1981-01-01
A summary of the cost data reviewed as well as conclusions and recommendations are presented. Cost and programmatic aspects of Rockwell's SPS CR-2 reference configuration were based on the results of several contracts with NASA and independent company-sponsored activities by the Space Operations and Satellite Systems Division of Rockwell International.
ERIC Educational Resources Information Center
Faas, Stefan; Wu, Shu-chen; Geiger, Steffen
2017-01-01
In order to reflect international reform movements in a system- and culture-comparative perspective, the following article investigates the early childhood education systems in Germany and in Hong Kong, with reference to the respective social and educational roots, pedagogical development lines, and basic educational approaches. In addition,…
47 CFR 1.10009 - What are the steps for electronic filing?
Code of Federal Regulations, 2011 CFR
2011-10-01
... International Bureau Filing System § 1.10009 What are the steps for electronic filing? (a) Step 1: Register for... may obtain an FRN either directly from the Commission Registration System (CORES) at http://www.fcc... application. You can determine the amount of your fee in three ways: (i) You can refer to § 1.1107, (ii) You...
2012-01-01
precision and accuracy. For instance, in international time metrology, two-way satellite time and frequency transfer ( TWSTFT ) (see e.g. [1] and...can act as a time transfer system that is complementary to other high quality systems such as TWSTFT and GPS. REFERENCES [1] J. Levine. “A
[Blood transfusion audit methodology: the auditors, reference systems and audit guidelines].
Chevrolle, F; Hadzlik, E; Arnold, J; Hergon, E
2000-12-01
The audit has become an essential aspect of the blood transfusion sector, and is a management tool that should be used judiciously. The main types of audit that can be envisaged in blood transfusion are the following: operational audit concerning a predetermined activity; systems quality audit; competence audit, combining the operational audit on a specific activity with quality management, e.g., laboratory accreditation; audit of the environmental management system; and social audit involving the organization of an activity and the management of human resources. However, the main type of audit considered in this article is the conformity audit, which in this context does not refer to internal control but to conformity with an internal guideline issued by the French National Blood Service. All audits are carried out on the basis of a predescribed method (contained in ISO 10 011). The audit is a system of investigation, evaluation and measurement, and also a means of continuous assessment and therefore improvement. The audit is based on set guidelines, but in fact consists of determining the difference between the directions given and what has actually been done. Auditing requires operational rigor and integrity, and has now become a profession in its own right.
A reference radiosonde system for climate and weather research: IHOP experience
NASA Astrophysics Data System (ADS)
Wang, Junhong; Hock, Terry F.; Lauritsen, Dean; Cole, Harold L.; Beierle, Kathryn; Chamberlain, Ned; Parsons, David B.; Carlson, David J.
2003-04-01
Global radiosonde data are required by meteorological analysis centers for initializing numerical prediction models for weather forecasting, and represent an increasingly valuable resource for studies of climate change and in the development, calibration and validation of retrieval techniques for atmospheric temperature and water vapor profiles from satellite. Unfortunately, the usefulness of radiosonde data is limited by sensor accuracy, by data reporting practices, and by the fact that sonde and sensor types vary by location and with time. Numerous studies and reports have called for a reference sonde to serve as a transfer standard to compare and connect data from past, present and future sonde systems. We are working on developing a reference radiosonde system at the Atmospheric Technology Division (ATD) at NCAR. The reference radiosonde system will carry the best sensors, have a flexible infrastructure to host multiple and different user-provided sensors and will be recoverable to reduce costs. The first version of the reference radiosonde system was deployed in the Oklahoma panhandle and Dodge City, KS (NWS radiosonde site) during the International H2O Project (IHOP_2002). A total of sixteen reference sondes were launched during IHOP either with Vaisala RS80 or Sippican (VIZ) radiosondes. The humidity data from the reference humidity sensor (Snow White, SW) are compared with Vaisala and VIZ data. The comparisons show that (a) VIZ carbon hygristor fails to respond to humidity changes in the upper troposphere, (b) the carbon hygristor inside the reference sonde has slower response than that inside NWS VIZ sonde, (c) Vaisala RS80-H agrees with SW very well in the middle and lower troposphere, and (d) SW can detect cirrus clouds near the tropopause and possibly estimate their ice water content (IWC). The climate impacts of these results are also discussed.
Unification of height systems in the frame of GGOS
NASA Astrophysics Data System (ADS)
Sánchez, Laura
2015-04-01
Most of the existing vertical reference systems do not fulfil the accuracy requirements of modern Geodesy. They refer to local sea surface levels, are stationary (do not consider variations in time), realize different physical height types (orthometric, normal, normal-orthometric, etc.), and their combination in a global frame presents uncertainties at the metre level. To provide a precise geodetic infrastructure for monitoring the Earth system, the Global Geodetic Observing System (GGOS) of the International Association of Geodesy (IAG), promotes the standardization of the height systems worldwide. The main purpose is to establish a global gravity field-related vertical reference system that (1) supports a highly-precise (at cm-level) combination of physical and geometric heights worldwide, (2) allows the unification of all existing local height datums, and (3) guarantees vertical coordinates with global consistency (the same accuracy everywhere) and long-term stability (the same order of accuracy at any time). Under this umbrella, the present contribution concentrates on the definition and realization of a conventional global vertical reference system; the standardization of the geodetic data referring to the existing height systems; and the formulation of appropriate strategies for the precise transformation of the local height datums into the global vertical reference system. The proposed vertical reference system is based on two components: a geometric component consisting of ellipsoidal heights as coordinates and a level ellipsoid as the reference surface, and a physical component comprising geopotential numbers as coordinates and an equipotential surface defined by a conventional W0 value as the reference surface. The definition of the physical component is based on potential parameters in order to provide reference to any type of physical heights (normal, orthometric, etc.). The conversion of geopotential numbers into metric heights and the modelling of the reference surface (geoid or quasigeoid determination) are considered as steps of the realization. The vertical datum unification strategy is based on (1) the physical connection of height datums to determine their discrepancies, (2) joint analysis of satellite altimetry and tide gauge records to determine time variations of sea level at reference tide gauges, (3) combination of geometrical and physical heights in a well-distributed and high-precise reference frame to estimate the relationship between the individual vertical levels and the global one, and (4) analysis of GNSS time series at reference tide gauges to separate crustal movements from sea level changes. The final vertical transformation parameters are provided by the common adjustment of the observation equations derived from these methods.
The Global GNSS, SLR, VLBI, and DORIS Networks and their Support of GGOS: IGS+ILRS+IVS+IDS
NASA Technical Reports Server (NTRS)
Noll, Carey
2008-01-01
The global network of the International GNSS Service (IGS), the International Laser Ranging Service (ILRS), the International VLBI Service for Geodesy and Astrometry (IVS), and the International DORIS Service (IDS) are part of the ground-based infrastructure for GGOS. The observations obtained from these global networks provide for the determination and maintenance of the International Terrestrial Reference Frame (ITRF), an accurate set of positions and velocities that provides a stable coordinate system allowing scientists ts to link measurements over space and time. Many of these sites offer co-location of two or more techniques. Co-location provides integration of technique-specific networks into the ITRF as well as an assessment/validation of the quality and accuracy of the resulting measurements. As of fall 2008, these networks consisted of 410 GNSS sites, 42 laser ranging sites, 45 VLBI sites, and 58 DORIS sites. This poster will illustrate the global coverage of these networks, highlighting inter-technique co-locations, and show the importance of these networks 60 the underlying goals of GGOS including providing the observational basis to maintain a stable, accurate, global reference frame.
77 FR 64724 - International Mail Manual; Incorporation by Reference
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... POSTAL SERVICE 39 CFR Part 20 International Mail Manual; Incorporation by Reference AGENCY: Postal... Standards of the United States Postal Service, International Mail Manual (IMM[supreg]) dated June 24, 2012... International Mail Manual was issued on June 24, 2012, and was updated with postal bulletin revisions through...
46 CFR 59.01-2 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING REPAIRS TO BOILERS...-ENG), Attn: Office of Design and Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin Luther... below. (b) American Society of Mechanical Engineers (ASME) International, Three Park Avenue, New York...
46 CFR 59.01-2 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING REPAIRS TO BOILERS...-ENG), Attn: Office of Design and Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin Luther... below. (b) American Society of Mechanical Engineers (ASME) International, Three Park Avenue, New York...
Evolution of Timescales from Astronomy to Physical Metrology
2011-07-20
2000 [7] recommended the use of the ‘non-rotating origin’ both in the Geocentric Celestial Reference System (GCRS) and the International Terrestrial...timescale defined in a geocentric reference frame with the SI second as realized on the rotating geoid as the scale unit’ [30, 31]. This meant that it was...of the new timescale for apparent geocentric ephemerides, will be 1977 January 1d.0003725 (1d 00h 00m 32.184s) exactly. (b) The unit of this timescale
Preface: The International Reference Ionosphere (IRI) at equatorial latitudes
NASA Astrophysics Data System (ADS)
Reinisch, Bodo; Bilitza, Dieter
2017-07-01
This issue of Advances in Space Research includes papers that report and discuss improvements of the International Reference Ionosphere (IRI). IRI is the international standard for the representation of the plasma in Earth's ionosphere and recognized as such by the Committee on Space Research (COSPAR), the International Union of Radio Science (URSI), the International Telecommunication Union (ITU), and the International Standardization Organization (ISO). As requested, particularly by COSPAR and URSI, IRI is an empirical model relying on most of the available and reliable ground and space observations of the ionosphere. As new data become available and as older data sources are fully exploited the IRI model undergoes improvement cycles to stay as close to the existing data record as possible. The latest episode of this process is documented in the papers included in this issue using data from the worldwide network of ionosondes, from a few of the incoherent scatter radars, from the Alouette and ISIS topside sounders, and from the Global Navigation Satellite Systems (GNSS). The focus of this issue is on the equatorial and low latitude region that is of special importance for ionospheric physics because it includes the largest densities and steep density gradients in the double hump latitudinal structure, the Equatorial Ionization Anomaly (EIA), which is characteristic for this region.
ERIC Educational Resources Information Center
Parker, Philip D.; Marsh, Herbert W.; Ludtke, Oliver; Trautwein, Ulrich
2013-01-01
The internal/external frame of reference and the big-fish-little-pond effect are two major models of academic self-concept formation which have considerable theoretical and empirical support. Integrating the domain specific and compensatory processes of the internal/external frame of reference model with the big-fish-little-pond effect suggests a…
2005-04-22
References [1] Janson S, Helvajian H and Robinson E 1993 The concept of nanosatellite for revolutionary, low-cost space systems 44th International...technologies J. Micromech. Microeng. 8 54–6 [4] Helvajian H 1997 Microengineering Technology for Space Systems (Reston, VA: AIAA) [5] Ketsdever A D 2000 System...nanosatellite applications (POSTPRINT) 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Andrew D. Ketsdever (AFRL/PRSA); Riki H . Lee and
NASA Astrophysics Data System (ADS)
Perrot, F.
1991-12-01
We report results of Helmholtz-free-energy and internal-energy calculations using the modified hypernetted-chain (MHNC) equation method, in the formulation of Lado, Foiles, and Ashcroft [Phys. Rev. A 28, 2374 (1983)], for a model plasma of ions linearly screened by electrons. The results are compared with HNC calculations (no Bridge term), with variational calculations using a hard-spheres reference system, and with a numerical fit of Monte Carlo simulations.
2004-01-01
International Earth Rotation and Reference Systems Service (IERS) Service International de la Rotation Terrestre et des Systèmes de Référence IERS...Equation for the determination of the density of moist air (1981/91),” Metrologia , 29, pp. 67–70. Giacomo, P., 1982, “Equation for the determination of...the density of moist air (1981),” Metrologia , 18, pp. 33–40. Herring, T. A., 1992, “Modeling Atmospheric Delays in the Analysis of Space Geodetic Data
Koskinen, Hanna; Mikkola, Hennamari; Saastamoinen, Leena K; Ahola, Elina; Martikainen, Jaana E
2015-12-01
To analyze the medium- to long-term impact of generic substitution and the reference price system on the daily cost of antipsychotics in Finland. The additional impact of reference pricing over and above previously implemented generic substitution was also assessed. An interrupted time series design with a control group and segmented regression analysis was used to estimate the effect of the implementation of generic substitution and the reference price system on the daily cost of antipsychotics. The data have 69 monthly values of the average daily cost for each of the studied antipsychotics: 39 months before and 30 months after the introduction of reference pricing. For one of the studied antipsychotic, the time before the introduction of reference pricing could be further divided into time before and after the introduction of generic substitution. According to the model, 2.5 years after the implementation of reference pricing, the daily cost of the studied antipsychotics was 24.6% to 50.6% lower than it would have been if reference pricing had not been implemented. Two and a half years after the implementation of the reference price system, however, the additional impact of reference pricing over and above previously implemented generic substitution was modest, less than 1 percentage point. Although the price competition induced by reference pricing decreased the prices of antipsychotics in Finland in the short-term, the prices had a tendency to stagnate or even to turn in an upward direction in the medium- to long-term. Furthermore, the additional impact of reference pricing over and above previously implemented generic substitution remained quite modest. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Arriaga-Nava, Roberto; Valencia-Sánchez, Jesús-Salvador; Rosas-Peralta, Martin; Garrido-Garduño, Martin; Calderón-Abbo, Moisés
2015-01-01
To review the existing evidence on the role of prehospital thrombolysis in patients with ST-segment elevation acute myocardial infarction (STEMI) as part of a strategy of cutting edge to reduce the time of coronary reperfusion and as a consequence improves both the survival and function. We used the technique of exploration-reduction-evaluation-analysis and synthesis of related studies, with an overview of current recommendations, data from controlled clinical trials and from the national and international registries about the different strategies for STEMI reperfusion. In total, we examined 186 references on prehospital thrombolysis, 130 references in times door-treatment, 139 references in STEMI management and national and international registries as well as 135 references on rescue and primary percutaneous coronary intervention for STEMI. Finally the 48 references that were more relevant and informative were retained. The «time» factor is crucial in the success of early reperfusion in STEMI especially if thrombolysis is applied correctly during the prehospital time. The primary percutaneous coronary intervention is contingent upon its feasibility before 120 min from the onset of symptoms. In our midst to internationally, thrombolysis continues to be a strategy with great impact on their expectations of life and function of patients. Telecommunication systems should be incorporate in real time to the priority needs of catastrophic diseases such as STEMI where life is depending on time. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
NASA Technical Reports Server (NTRS)
Shively, Jay
2017-01-01
A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.
The International Design Study for the Neutrino Factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, K.
2008-02-21
The International Design Study for a future Neutrino Factory and super-beam facility (the ISS) established the physics case for a high-precision programme of long-baseline neutrino-oscillation measurements. The ISS also identified baseline specifications for the Neutrino Factory accelerator complex and the neutrino detector systems. This paper summarises the objectives of the International Design Study for the Neutrino Factory (the IDS-NF). The IDS-NF will build on the work of the ISS to deliver a Reference Design Report for the Neutrino Factory by 2012/13 and an Interim Design Report by 2010/11.
Rossi, Patrizia; Pozio, Edoardo
2008-01-01
The European Community Regulation (EC) No. 2075/2005 lays down specific rules on official controls for the detection of Trichinella in fresh meat for human consumption, recommending the pooled-sample digestion method as the reference method. The aim of this document is to provide specific guidance to implement an appropriate Trichinella digestion method by a laboratory accredited according to the ISO/IEC 17025:2005 international standard, and performing microbiological testing following the EA-04/10:2002 international guideline. Technical requirements for the correct implementation of the method, such as the personnel competence, specific equipments and reagents, validation of the method, reference materials, sampling, quality assurance of results and quality control of performance are provided, pointing out the critical control points for the correct implementation of the digestion method.
Infrared non-destructive evaluation method and apparatus
Baleine, Erwan; Erwan, James F; Lee, Ching-Pang; Stinelli, Stephanie
2014-10-21
A method of nondestructive evaluation and related system. The method includes arranging a test piece (14) having an internal passage (18) and an external surface (15) and a thermal calibrator (12) within a field of view (42) of an infrared sensor (44); generating a flow (16) of fluid characterized by a fluid temperature; exposing the test piece internal passage (18) and the thermal calibrator (12) to fluid from the flow (16); capturing infrared emission information of the test piece external surface (15) and of the thermal calibrator (12) simultaneously using the infrared sensor (44), wherein the test piece infrared emission information includes emission intensity information, and wherein the thermal calibrator infrared emission information includes a reference emission intensity associated with the fluid temperature; and normalizing the test piece emission intensity information against the reference emission intensity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rohatgi, Upendra S.
Nuclear reactor codes require validation with appropriate data representing the plant for specific scenarios. The thermal-hydraulic data is scattered in different locations and in different formats. Some of the data is in danger of being lost. A relational database is being developed to organize the international thermal hydraulic test data for various reactor concepts and different scenarios. At the reactor system level, that data is organized to include separate effect tests and integral effect tests for specific scenarios and corresponding phenomena. The database relies on the phenomena identification sections of expert developed PIRTs. The database will provide a summary ofmore » appropriate data, review of facility information, test description, instrumentation, references for the experimental data and some examples of application of the data for validation. The current database platform includes scenarios for PWR, BWR, VVER, and specific benchmarks for CFD modelling data and is to be expanded to include references for molten salt reactors. There are place holders for high temperature gas cooled reactors, CANDU and liquid metal reactors. This relational database is called The International Experimental Thermal Hydraulic Systems (TIETHYS) database and currently resides at Nuclear Energy Agency (NEA) of the OECD and is freely open to public access. Going forward the database will be extended to include additional links and data as they become available. https://www.oecd-nea.org/tiethysweb/« less
2007-11-01
overshadowed by an ideological confrontation of the two social value systems in the opposing coalitions, commonly referred to as the Cold War. It is possible...economic, social , political, and ideological national systems and foreign- policy preferences. The two superpowers’ military confrontation—a...svr.gov.ru. 12 Romashkina, N.P. Severokoreiskaia iadernaia problema : domysly i real’nost’. (The North Korean Nuclear Problem: Theories and Reality). Vol
46 CFR 52.01-1 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General... Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington, DC 20593...) American Society of Mechanical Engineers (ASME) International, Three Park Avenue, New York, NY 10016-5990...
46 CFR 52.01-1 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General... Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington, DC 20593...) American Society of Mechanical Engineers (ASME) International, Three Park Avenue, New York, NY 10016-5990...
Quality Assurance in Engineering Education: Comparison of Accreditation Schemes and ISO 9001.
ERIC Educational Resources Information Center
Karapetrovic, Stanislav; Rajamani, Divakar; Willborn, Walter
1998-01-01
Outlines quality assurance schemes for distance-education technologies that are based on the ISO 9000 family of international quality-assurance standards. Argues that engineering faculties can establish such systems on the basis of and integrated with accreditation schemes. Contains 34 references. (DDR)
Integrating the Wall Street Journal into AIS Courses
ERIC Educational Resources Information Center
Kohlmeyer, James M., III
2008-01-01
While it is important for accounting information systems (AIS) students to understand computer technology, internal controls and business processes, such knowledge is of little use without reference to appropriate contexts. Integrating Wall Street Journal (WSJ) readings and discussions into AIS classes can enrich learning by stimulating…
Conway, Kristin M; Ciafaloni, Emma; Matthews, Dennis; Westfield, Chris; James, Kathy; Paramsothy, Pangaja; Romitti, Paul A
2018-07-01
Duchenne and Becker muscular dystrophies, collectively referred to as dystrophinopathies, are X-linked recessive diseases that affect dystrophin production resulting in compromised muscle function across multiple systems. The International Classification of Functioning, Disability and Health provides a systematic classification scheme from which body functions affected by a dystrophinopathy can be identified and used to examine functional health. The infrastructure of the Muscular Dystrophy Surveillance, Tracking, and Research Network was used to identify commonly affected body functions and link selected functions to clinical surveillance data collected through medical record abstraction. Seventy-one (24 second-, 41 third- and 7 fourth-level) body function categories were selected via clinician review and consensus. Of these, 15 of 24 retained second-level categories were linked to data elements from the Muscular Dystrophy Surveillance, Tracking, and Research Network surveillance database. Our findings support continued development of a core set of body functions from the International Classification of Functioning, Disability and Health system that are representative of disease progression in dystrophinopathies and the incorporation of these functions in standardized evaluations of functional health and implementation of individualized rehabilitation care plans. Implications for Rehabilitation Duchenne and Becker muscular dystrophies, collectively referred to as dystrophinopathies, are X-linked recessive disorders that affect the production of dystrophin resulting in compromised muscle function across multiple systems. The severity and progressive nature of dystrophinopathies can have considerable impact on a patient's participation in activities across multiple life domains. Our findings support continued development of an International Classification of Functioning, Disability and Health core set for childhood-onset dystrophinopathies. A standardized dystrophinopathy International Classification of Functioning, Disability and Health documentation form can be used as a screening tool by rehabilitation professionals and for patient goal setting when developing rehabilitation plans. Patient reports of perceived functional health should be incorporated into the rehabilitation plan and therapeutic progress monitored by a standardized form.
The Rockwell SR-100G reactor turboelectric space power system
NASA Technical Reports Server (NTRS)
Anderson, R. V.
1985-01-01
During FY 1982 and 1983, Rockwell International performed system and subsystem studies for space reactor power systems. These studies drew on the expertise gained from the design and flight of the SNAP-10A space nuclear reactor system. These studies, performed for the SP-100 Program, culminated in the selection of a reactor-turboelectric (gas Brayton) system for the SP-100 application; this system is called the SR-100G. This paper describes the features of the system and provides references where more detailed information can be obtained.
İnal, Tolga; Ataç, Gökçe
2014-01-01
PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331
Rehani, Madan M; Berris, Theocharis
2012-01-01
Objectives To assess the following themes among referring physicians: (A) importance of acquiring information about previous diagnostic exposures; (B) knowledge about radiation doses involved, familiarity with radiation units and, age-related radiosensitivity; (C) opinion on whether patients should be provided information about radiation dose and (D) self-assessment of appropriateness of referrals. Design A prospective survey using a web-based questionnaire. Setting International survey among referring physicians. Participants Referring physicians from 28 countries. Main outcome measures Knowledge, opinion and practice of the four themes of the survey. Results All 728 responses from 28 countries (52.3% from developed and 47.7% from developing countries) indicated that while the vast majority (71.7%) of physicians feel that being aware of history of CT scans would always or mostly lead them to a better decision on referring patients for CT scans, only 43.4% often enquire about it. The majority of referring physicians (60.5%) stated that having a system that provides quick information about patient exposure history would be useful. The knowledge about radiation doses involved is poor, as only one-third (34.7%) of respondents chose the correct option of the number of chest x-rays with equivalence of a CT scan. In total, 70.9% of physicians stated that they do not feel uncomfortable when patients ask about radiation risk from CT scans they prescribe. Most physicians (85.6%) assessed that they have rarely prescribed CT scans of no clinical use in patient management. Conclusions This first ever multinational survey among referring physicians from 28 countries indicates support for a system that provides radiation exposure history of the patient, demonstrates poor knowledge about radiation doses, supports radiation risk communication with patients and mandatory provisions for justification of a CT examination. PMID:22997065
Moestue, H; de Pee, S; Hall, A; Hye, A; Sultana, N; Ishtiaque, M Z; Huq, N; Bloem, M W
2004-05-01
To examine sex differences in height-for-age z-scores and the percentage stunting among Bangladeshi children estimated using three growth references. Data collected between 1990 and 1999 by Helen Keller International's nutritional surveillance system in rural Bangladesh were analyzed for 504 358 children aged 6-59 months. Height-for-age z-scores were estimated using the 1977 NCHS, 2000 CDC and 1990 British growth references. The shape of the growth curves for Bangladeshi boys and girls, and their positions relative to one another, depend on which of the three growth references is used. At 6 months of age the British reference showed no sex difference whereas the NCHS and CDC showed girls to have higher average z-scores than boys by 0.14 and 0.28 s.d., respectively. While all references showed a faster deterioration of girls' z-scores from 6 to 24 months, the magnitude and direction of the sex differences, and how they changed with age, were different. There was greater disagreement about girls' z-scores than boys. Discontinuities at 24 months in the NCHS and CDC produced jagged curves whereas the British curves were smooth. The assessment of sex differences in linear growth depends on the growth reference used. Reasons for the different results need to be determined and may aid the final development of the new WHO international growth reference and the guidelines for its use. The findings suggest that anthropometry as a tool to explore the effects of societal gender inequality must be used with caution.
NASA Technical Reports Server (NTRS)
Bauschlicher, Charles W., Jr.; Partridge, Harry; Scuseria, Gustavo E.
1992-01-01
The correlation contribution to the M-C binding energy for the MCH2(+) systems can exceed 100 kcal/mol. At the self-consistent field (SCF) level, these systems can be more than 50 kcal/mol above the fragment energies. In spite of the poor zeroth-order reference, the coupled cluster single and double excitation method with a perturbational estimate of triple excitations, CCSD(T), method is shown to provide an accurate description of these systems. The maximum difference between the CCSD(T) and internally contracted averaged coupled-pair functional binding energies is 1.5 kcal/mol for CrCH2(+), with the remaining systems agreeing to within 1.0 kcal/mol.
Antonacci, Michael A; Zhang, Le; Burant, Alex; McCallister, Drew; Branca, Rosa T
2018-08-01
To assess the effect of macroscopic susceptibility gradients on the gas-phase referenced dissolved-phase 129 Xe (DPXe) chemical shift (CS) and to establish the robustness of a water-based referencing system for in vivo DPXe spectra. Frequency shifts induced by spatially varying magnetic susceptibility are calculated by finite-element analysis for the human head and chest. Their effect on traditional gas-phase referenced DPXe CS is then assessed theoretically and experimentally. A water-based referencing system for the DPXe resonances that uses the local water protons as reference is proposed and demonstrated in vivo in rats. Across the human brain, macroscopic susceptibility gradients can induce an apparent variation in the DPXe CS of up to 2.5 ppm. An additional frequency shift as large as 6.5 ppm can exist between DPXe and gas-phase resonances. By using nearby water protons as reference for the DPXe CS, the effect of macroscopic susceptibility gradients is eliminated and consistent CS values are obtained in vivo, regardless of shimming conditions, region of interest analyzed, animal orientation, or lung inflation. Combining in vitro and in vivo spectroscopic measurements finally enables confident assignment of some of the DPXe peaks observed in vivo. To use hyperpolarized xenon as a biological probe in tissues, the DPXe CS in specific organs/tissues must be reliably measured. When the gas-phase is used as reference, variable CS values are obtained for DPXe resonances. Reliable peak assignments in DPXe spectra can be obtained by using local water protons as reference. Magn Reson Med 80:431-441, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Graphical Language Games: Interactional Constraints on Representational Form
ERIC Educational Resources Information Center
Healey, Patrick G. T.; Swoboda, Nik; Umata, Ichiro; King, James
2007-01-01
The emergence of shared symbol systems is considered to be a pivotal moment in human evolution and human development. These changes are normally explained by reference to changes in people's internal cognitive processes. We present 2 experiments which provide evidence that changes in the external, collaborative processes that people use to…
Career Education for Physically Disabled Students: A Bibliography.
ERIC Educational Resources Information Center
Stieglitz, Maria N.; Cohen, James S.
The bibliography contains over 3,000 citations on all aspects of career education and provides a frame of reference to adapt programs for the physically disabled. Sources were derived from the Educational Resources Information Center (ERIC) system, Dissertation Abstracts International (1972-1977), Education Index (1971-1977), and various public…
Nursing Education in China: Opportunities for International Collaboration.
ERIC Educational Resources Information Center
Anders, Robert L.; Harrigan, Rosanne
2002-01-01
In China, nursing has been a secondary-level trade, although modernization and pressures on the health care system are increasing the prevalence of degree programs. The ministry of health beginning to regulate practice and establish standards. Education of key administrators and stakeholders is crucial. (Contains 11 references.) (SK)
Critical Challenges and Dilemmas for Catholic Education Leadership Internationally
ERIC Educational Resources Information Center
Gleeson, Jim
2015-01-01
This paper considers the challenges faced by contemporary Catholic Education systems with particular reference to the contrast between the prevailing neo-liberal agenda and gospel values. It explicates this contrast from the perspectives of current critiques of the influence of the new manageralism in education and relevant literature on Catholic…
Elberg, Gerard; Elberg, Dorit; Logan, Charlotte J; Chen, Lijuan; Turman, Martin A
2006-01-01
Progressive renal fibrotic disease is accompanied by the massive accumulation of myofibroblasts as defined by alpha smooth muscle actin (alphaSMA) expression. We quantitated gene expression using real-time RT-PCR analysis during conversion of primary cultured human renal tubular cells (RTC) to myofibroblasts after treatment with transforming growth factor-beta1 (TGF-beta1). We report herein the limitations of commonly used reference genes for mRNA quantitation. We determined the expression of alphaSMA and megakaryoblastic leukemia-1 (MKL1), a transcriptional regulator of alphaSMA, by quantitative real-time PCR using three common internal controls, glyceraldehyde-3-phosphate dehydrogenase (GAPDH), cyclophilin A and 18S rRNA. Expression of GAPDH mRNA and cyclophilin A mRNA, and to a lesser extent, 18S rRNA levels varied over time in culture and with exposure to TGF-beta1. Thus, depending on which reference gene was used, TGF-beta1 appeared to have different effects on expression of MKL1 and alphaSMA. RTC converting to myofibroblasts in primary culture is a valuable system to study renal fibrosis in humans. However, variability in expression of reference genes with TGF-beta1 treatment illustrates the need to validate mRNA quantitation with multiple reference genes to provide accurate interpretation of fibrosis studies in the absence of a universal internal standard for mRNA expression. 2006 S. Karger AG, Basel.
Use of the ICRP system for the protection of marine ecosystems.
Telleria, D; Cabianca, T; Proehl, G; Kliaus, V; Brown, J; Bossio, C; Van der Wolf, J; Bonchuk, I; Nilsen, M
2015-06-01
The International Commission on Radiological Protection (ICRP) recently reinforced the international system of radiological protection, initially focused on humans, by identifying principles of environmental protection and proposing a framework for assessing impacts of ionising radiation on non-human species, based on a reference flora and fauna approach. For this purpose, ICRP developed dosimetric models for a set of Reference Animals and Plants, which are representative of flora and fauna in different environments (terrestrial, freshwater, marine), and produced criteria based on information on radiation effects, with the aim of evaluating the level of potential or actual radiological impacts, and as an input for decision making. The approach developed by ICRP for flora and fauna is consistent with the approach used to protect humans. The International Atomic Energy Agency (IAEA) includes considerations on the protection of the environment in its safety standards, and is currently developing guidelines to assess radiological impacts based on the aforementioned ICRP approach. This paper presents the method developed by IAEA, in a series of meetings with international experts, to enable assessment of the radiological impact to the marine environment in connection with the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (London Convention 1972). This method is based on IAEA's safety standards and ICRP's recommendations, and was presented in 2013 for consideration by representatives of the contracting parties of the London Convention 1972; it was approved for inclusion in its procedures, and is in the process of being incorporated into guidelines. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
37 CFR 1.78 - Claiming benefit of earlier filing date and cross-references to other applications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and cross-references to other applications. (a)(1) A nonprovisional application or international...-filed copending nonprovisional applications or international applications designating the United States... nonprovisional application or international application designating the United States of America, each prior...
NASA Astrophysics Data System (ADS)
Coulot, David; Richard, Jean-Yves
2017-04-01
Many major indicators of climate change are monitored with space observations (sea level rise from satellite altimetry, ice melting from dedicated satellites, etc.). This monitoring is highly dependent on references (positions and velocities of ground observing instruments, orbits of satellites, etc.) that only geodesy can provide. The current accuracy of these references does not permit to fully support the challenges that the constantly evolving Earth system gives rise to, and can consequently limit the accuracy of these indicators. For this reason, in the framework of the Global Geodetic Observing System (GGOS), stringent requirements are fixed to the International Terrestrial Reference Frame (ITRF) for the next decade: an accuracy at the level of 1 mm and a stability at the level of 0.1 mm/yr. This means an improvement of the current quality of ITRF by a factor of 5-10. Improving the quality of the geodetic references is an issue which requires a thorough reassessment of the methodologies involved. The most relevant and promising method to improve this quality is the direct combination (Combination at Observation Level - COL) of the space-geodetic measurements used to compute the official references of the International Earth Rotation and Reference Systems Service (IERS). The GEODESIE project aims at (i) determining highly-accurate global and consistent references (time series of Terrestrial Reference Frames and Celestial Reference Frames, of Earth's Orientation Parameters, and orbits of Earth's observation satellites) and (ii) providing the geophysical and climate research communities with these references, for a better estimation of geocentric sea level rise, ice mass balance and on-going climate changes. Time series of sea levels computed from altimetric data and tide gauge records with these references (orbits of satellite altimeters, Terrestrial Reference Frames and related vertical velocities of stations) will also be provided. The geodetic references will be essential bases for Earth's observation and monitoring to support the challenges of the century. The geocentric time series of sea levels will permit to better apprehend (i) the drivers of the global mean sea level rise and of regional variations of sea level and (ii) the contribution of the global climate change induced by anthropogenic greenhouse gases emissions to these drivers. All the results and computation and quality assessment reports will be available on a Website designed and opened in the Summer of 2017. This project, supported by the French Agence Nationale de la Recherche (ANR) for the period 2017-2020, will be an unprecedented opportunity to provide the French Groupe de Recherche de Géodésie Spatiale (GRGS) with complete simulation and data processing capabilities to prepare the future arrival of space missions such as the European Geodetic Reference Antenna in SPace (E-GRASP) and to significantly contribute to the GGOS with accurate references.
Bailey, Timothy S.; Klaff, Leslie J.; Wallace, Jane F.; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A.
2016-01-01
Background: As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Methods: Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects’ self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. Results: In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (−0.64% to −2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. Conclusions: These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. PMID:26902794
NASA Astrophysics Data System (ADS)
Mirzaeinia, Ali; Feyzi, Farzaneh; Hashemianzadeh, Seyed Majid
2018-03-01
Based on Wertheim's second order thermodynamic perturbation theory (TPT2), equations of state (EOSs) are presented for the fluid and solid phases of tangent, freely jointed spheres. It is considered that the spheres interact with each other through the Weeks-Chandler-Anderson (WCA) potential. The developed TPT2 EOS is the sum of a monomeric reference term and a perturbation contribution due to bonding. MC NVT simulations are performed to determine the structural properties of the reference system in the reduced temperature range of 0.6 ≤ T* ≤ 4.0 and the packing fraction range of 0.1 ≤ η ≤ 0.72. Mathematical functions are fitted to the simulation results of the reference system and employed in the framework of Wertheim's theory to develop TPT2 EOSs for the fluid and solid phases. The extended EOSs are compared to the MC NPT simulation results of the compressibility factor and internal energy of the fully flexible chain systems. Simulations are performed for the WCA chain system for chain lengths of up to 15 at T* = 1.0, 1.5, 2.0, 3.0. Across all the reduced temperatures, the agreement between the results of the TPT2 EOS and MC simulations is remarkable. Overall Average Absolute Relative Percent Deviation at T* = 1.0 for the compressibility factor in the entire chain lengths we covered is 0.51 and 0.77 for the solid and fluid phases, respectively. Similar features are observed in the case of residual internal energy.
Mirzaeinia, Ali; Feyzi, Farzaneh; Hashemianzadeh, Seyed Majid
2018-03-14
Based on Wertheim's second order thermodynamic perturbation theory (TPT2), equations of state (EOSs) are presented for the fluid and solid phases of tangent, freely jointed spheres. It is considered that the spheres interact with each other through the Weeks-Chandler-Anderson (WCA) potential. The developed TPT2 EOS is the sum of a monomeric reference term and a perturbation contribution due to bonding. MC NVT simulations are performed to determine the structural properties of the reference system in the reduced temperature range of 0.6 ≤ T* ≤ 4.0 and the packing fraction range of 0.1 ≤ η ≤ 0.72. Mathematical functions are fitted to the simulation results of the reference system and employed in the framework of Wertheim's theory to develop TPT2 EOSs for the fluid and solid phases. The extended EOSs are compared to the MC NPT simulation results of the compressibility factor and internal energy of the fully flexible chain systems. Simulations are performed for the WCA chain system for chain lengths of up to 15 at T* = 1.0, 1.5, 2.0, 3.0. Across all the reduced temperatures, the agreement between the results of the TPT2 EOS and MC simulations is remarkable. Overall Average Absolute Relative Percent Deviation at T* = 1.0 for the compressibility factor in the entire chain lengths we covered is 0.51 and 0.77 for the solid and fluid phases, respectively. Similar features are observed in the case of residual internal energy.
Overview of ICRP Committee 5: protection of the environment.
Larsson, C-M
2016-06-01
Protection of the environment is integral to the system of radiological protection, as outlined in the 2007 Recommendations of the International Commission on Radiological Protection (ICRP, Publication 103). The Commission's activities in this area are mainly pursued by Committee 5 and its associated Task Groups. Publication 91 broadly outlines the approach to radiological protection of the environment, and its alignment with approaches to environmental protection from hazardous substances in general. Publications 108 and 114 provide the cornerstones of the environmental protection system and relevant databases. Publication 124 considers its application in planned, existing, and emergency exposure situations. The system centres on 12 Reference Animals and Plants (RAPs) with broad relevance for environmental protection based on their ubiquity and significance as well as other criteria, as described in Publication 108 The databases comprise general biology of the RAPs, transfer parameters, dose conversion coefficients, and effects data. Derived Consideration Reference Levels (DCRLs) were established for each RAP; a DCRL represents a band of dose rates that might result in some deleterious effects in individuals of that type of RAP. Newly established Task Group 99 will compile the RAP-specific reference information into monographs, with the view of updating information and improving the applicability of the system in different exposure situations. For certain scenarios, more precise and ecosystem-specific protection benchmarks may be justified, which would have to be informed by consideration of representative organisms (i.e. representative of a particular ecosystem and relevant to the specific scenario; Publication 124). Committee 5 will explore this further, making use of a limited number of case studies. © The International Society for Prosthetics and Orthotics.
Enhanced pid vs model predictive control applied to bldc motor
NASA Astrophysics Data System (ADS)
Gaya, M. S.; Muhammad, Auwal; Aliyu Abdulkadir, Rabiu; Salim, S. N. S.; Madugu, I. S.; Tijjani, Aminu; Aminu Yusuf, Lukman; Dauda Umar, Ibrahim; Khairi, M. T. M.
2018-01-01
BrushLess Direct Current (BLDC) motor is a multivariable and highly complex nonlinear system. Variation of internal parameter values with environment or reference signal increases the difficulty in controlling the BLDC effectively. Advanced control strategies (like model predictive control) often have to be integrated to satisfy the control desires. Enhancing or proper tuning of a conventional algorithm results in achieving the desired performance. This paper presents a performance comparison of Enhanced PID and Model Predictive Control (MPC) applied to brushless direct current motor. The simulation results demonstrated that the PSO-PID is slightly better than the PID and MPC in tracking the trajectory of the reference signal. The proposed scheme could be useful algorithms for the system.
Construction Theory and Noise Analysis Method of Global CGCS2000 Coordinate Frame
NASA Astrophysics Data System (ADS)
Jiang, Z.; Wang, F.; Bai, J.; Li, Z.
2018-04-01
The definition, renewal and maintenance of geodetic datum has been international hot issue. In recent years, many countries have been studying and implementing modernization and renewal of local geodetic reference coordinate frame. Based on the precise result of continuous observation for recent 15 years from state CORS (continuously operating reference system) network and the mainland GNSS (Global Navigation Satellite System) network between 1999 and 2007, this paper studies the construction of mathematical model of the Global CGCS2000 frame, mainly analyzes the theory and algorithm of two-step method for Global CGCS2000 Coordinate Frame formulation. Finally, the noise characteristic of the coordinate time series are estimated quantitatively with the criterion of maximum likelihood estimation.
The Global Geodetic Observing System: Space Geodesy Networks for the Future
NASA Technical Reports Server (NTRS)
Pearlman, Michael; Pavlis, Erricos; Ma, Chopo; Altamini, Zuheir; Noll, Carey; Stowers, David
2011-01-01
Ground-based networks of co-located space geodetic techniques (VLBI, SLR, GNSS. and DORIS) are the basis for the development and maintenance of the International Terrestrial Reference frame (ITRF), which is our metric of reference for measurements of global change, The Global Geodetic Observing System (GGOS) of the International Association of Geodesy (IAG) has established a task to develop a strategy to design, integrate and maintain the fundamental geodetic network and supporting infrastructure in a sustainable way to satisfy the long-term requirements for the reference frame. The GGOS goal is an origin definition at 1 mm or better and a temporal stability on the order of 0.1 mm/y, with similar numbers for the scale and orientation components. These goals are based on scientific requirements to address sea level rise with confidence, but other applications are not far behind. Recent studies including one by the US National Research Council has strongly stated the need and the urgency for the fundamental space geodesy network. Simulations are underway to examining accuracies for origin, scale and orientation of the resulting ITRF based on various network designs and system performance to determine the optimal global network to achieve this goal. To date these simulations indicate that 24 - 32 co-located stations are adequate to define the reference frame and a more dense GNSS and DORIS network will be required to distribute the reference frame to users anywhere on Earth. Stations in the new global network will require geologically stable sites with good weather, established infrastructure, and local support and personnel. GGOS wil seek groups that are interested in participation. GGOS intends to issues a Call for Participation of groups that would like to contribute in the network implementation and operation. Some examples of integrated stations currently in operation or under development will be presented. We will examine necessary conditions and challenges in designing a co-location station.
Internal validation of the RapidHIT® ID system.
Wiley, Rachel; Sage, Kelly; LaRue, Bobby; Budowle, Bruce
2017-11-01
Traditionally, forensic DNA analysis has required highly skilled forensic geneticists in a dedicated laboratory to generate short tandem repeat (STR) profiles. STR profiles are routinely used either to associate or exclude potential donors of forensic biological evidence. The typing of forensic reference samples has become more demanding, especially with the requirement in some jurisdictions to DNA profile arrestees. The Rapid DNA (RDNA) platform, the RapidHIT ® ID (IntegenX ® , Pleasanton, CA), is a fully automated system capable of processing reference samples in approximately 90min with minimal human intervention. Thus, the RapidHIT ID instrument can be deployed to non-laboratory environments (e.g., booking stations) and run by trained atypical personnel such as law enforcement. In order to implement the RapidHIT ID platform, validation studies are needed to define the performance and limitations of the system. Internal validation studies were undertaken with four early-production RapidHIT ID units. Reliable and concordant STR profiles were obtained from reference buccal swabs. Throughout the study, no contamination was observed. The overall first-pass success rate with an "expert-like system" was 72%, which is comparable to another current RDNA platform commercially available. The system's second-pass success rate (involving manual interpretation on first-pass inconclusive results) increased to 90%. Inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect typing by the instrument system; however, substrate (i.e., swab type) did impact typing success. Additionally, one desirable feature not available with other Rapid systems is that in the event of a system failed run, a swab can be recovered and subsequently re-analyzed in a new sample cartridge. Therefore, rarely should additional sampling or swab consumption be necessary. The RapidHIT ID system is a robust and reliable tool capable of generating complete STR profiles within the forensic DNA typing laboratory or with proper training in decentralized environments by non-laboratory personnel. Copyright © 2017 Elsevier B.V. All rights reserved.
CisLunar Habitat Internal Architecture Design Criteria
NASA Technical Reports Server (NTRS)
Jones, R.; Kennedy, K.; Howard, R.; Whitmore, M.; Martin, C.; Garate, J.
2017-01-01
BACKGROUND: In preparation for human exploration to Mars, there is a need to define the development and test program that will validate deep space operations and systems. In that context, a Proving Grounds CisLunar habitat spacecraft is being defined as the next step towards this goal. This spacecraft will operate differently from the ISS or other spacecraft in human history. The performance envelope of this spacecraft (mass, volume, power, specifications, etc.) is being defined by the Future Capabilities Study Team. This team has recognized the need for a human-centered approach for the internal architecture of this spacecraft and has commissioned a CisLunar Phase-1 Habitat Internal Architecture Study Team to develop a NASA reference configuration, providing the Agency with a "smart buyer" approach for future acquisition. THE CISLUNAR HABITAT INTERNAL ARCHITECTURE STUDY: Overall, the CisLunar Habitat Internal Architecture study will address the most significant questions and risks in the current CisLunar architecture, habitation, and operations concept development. This effort is achieved through definition of design criteria, evaluation criteria and process, design of the CisLunar Habitat Phase-1 internal architecture, and the development and fabrication of internal architecture concepts combined with rigorous and methodical Human-in-the-Loop (HITL) evaluations and testing of the conceptual innovations in a controlled test environment. The vision of the CisLunar Habitat Internal Architecture Study is to design, build, and test a CisLunar Phase-1 Habitat Internal Architecture that will be used for habitation (e.g. habitability and human factors) evaluations. The evaluations will mature CisLunar habitat evaluation tools, guidelines, and standards, and will interface with other projects such as the Advanced Exploration Systems (AES) Program integrated Power, Avionics, Software (iPAS), and Logistics for integrated human-in-the-loop testing. The mission of the CisLunar Habitat Internal Architecture Study is to become a forcing function to establish a common understanding of CisLunar Phase-1 Habitation Internal Architecture design criteria, processes, and tools. The scope of the CisLunar Habitat Internal Architecture study is to design, develop, demonstrate, and evaluate a Phase-1 CisLunar Habitat common module internal architecture based on design criteria agreed to by NASA, the International Partners, and Commercial Exploration teams. This task is to define the CisLunar Phase-1 Internal Architecture Government Reference Design, assist NASA in becoming a "smart buyer" for Phase-1 Habitat Concepts, and ultimately to derive standards and requirements from the Internal Architecture Design Process. The first step was to define a Habitat Internal Architecture Design Criteria and create a structured philosophy to be used by design teams as a filter by which critical aspects of consideration would be identified for the purpose of organizing and utilizing interior spaces. With design criteria in place, the team will develop a series of iterative internal architecture concept designs which will be assessed by means of an evaluation criteria and process. These assessments will successively drive and refine the design, leading to the combination and down-selection of design concepts. A single refined reference design configuration will be developed into in a medium-to-high fidelity mockup. A multi-day human-in-the-loop mission test will fully evaluate the reference design and validate its configuration. Lessons learned from the design and evaluation will enable the team to identify appropriate standards for Phase-1 CisLunar Habitat Internal Architecture and will enable NASA to develop derived requirements in support of maturing CisLunar Habitation capabilities. This paper will describe the criteria definition process, workshop event, and resulting CisLunar Phase-1 Habitat Internal Architecture Design Criteria.
NASA Technical Reports Server (NTRS)
Davis, George; Cary, Everett; Higinbotham, John; Burns, Richard; Hogie, Keith; Hallahan, Francis
2003-01-01
The paper will provide an overview of the web-based distributed simulation software system developed for end-to-end, multi-spacecraft mission design, analysis, and test at the NASA Goddard Space Flight Center (GSFC). This software system was developed for an internal research and development (IR&D) activity at GSFC called the Distributed Space Systems (DSS) Distributed Synthesis Environment (DSE). The long-term goal of the DSS-DSE is to integrate existing GSFC stand-alone test beds, models, and simulation systems to create a "hands on", end-to-end simulation environment for mission design, trade studies and simulations. The short-term goal of the DSE was therefore to develop the system architecture, and then to prototype the core software simulation capability based on a distributed computing approach, with demonstrations of some key capabilities by the end of Fiscal Year 2002 (FY02). To achieve the DSS-DSE IR&D objective, the team adopted a reference model and mission upon which FY02 capabilities were developed. The software was prototyped according to the reference model, and demonstrations were conducted for the reference mission to validate interfaces, concepts, etc. The reference model, illustrated in Fig. 1, included both space and ground elements, with functional capabilities such as spacecraft dynamics and control, science data collection, space-to-space and space-to-ground communications, mission operations, science operations, and data processing, archival and distribution addressed.
A Distributed Simulation Software System for Multi-Spacecraft Missions
NASA Technical Reports Server (NTRS)
Burns, Richard; Davis, George; Cary, Everett
2003-01-01
The paper will provide an overview of the web-based distributed simulation software system developed for end-to-end, multi-spacecraft mission design, analysis, and test at the NASA Goddard Space Flight Center (GSFC). This software system was developed for an internal research and development (IR&D) activity at GSFC called the Distributed Space Systems (DSS) Distributed Synthesis Environment (DSE). The long-term goal of the DSS-DSE is to integrate existing GSFC stand-alone test beds, models, and simulation systems to create a "hands on", end-to-end simulation environment for mission design, trade studies and simulations. The short-term goal of the DSE was therefore to develop the system architecture, and then to prototype the core software simulation capability based on a distributed computing approach, with demonstrations of some key capabilities by the end of Fiscal Year 2002 (FY02). To achieve the DSS-DSE IR&D objective, the team adopted a reference model and mission upon which FY02 capabilities were developed. The software was prototyped according to the reference model, and demonstrations were conducted for the reference mission to validate interfaces, concepts, etc. The reference model, illustrated in Fig. 1, included both space and ground elements, with functional capabilities such as spacecraft dynamics and control, science data collection, space-to-space and space-to-ground communications, mission operations, science operations, and data processing, archival and distribution addressed.
CDDIS: NASA's Archive of Space Geodesy Data and Products Supporting GGOS
NASA Technical Reports Server (NTRS)
Noll, Carey; Michael, Patrick
2016-01-01
The Crustal Dynamics Data Information System (CDDIS) supports data archiving and distribution activities for the space geodesy and geodynamics community. The main objectives of the system are to store space geodesy and geodynamics related data and products in a central archive, to maintain information about the archival of these data,to disseminate these data and information in a timely manner to a global scientific research community, and provide user based tools for the exploration and use of the archive. The CDDIS data system and its archive is a key component in several of the geometric services within the International Association of Geodesy (IAG) and its observing systemthe Global Geodetic Observing System (GGOS), including the IGS, the International DORIS Service (IDS), the International Laser Ranging Service (ILRS), the International VLBI Service for Geodesy and Astrometry (IVS), and the International Earth Rotation and Reference Systems Service (IERS). The CDDIS provides on-line access to over 17 Tbytes of dataand derived products in support of the IAG services and GGOS. The systems archive continues to grow and improve as new activities are supported and enhancements are implemented. Recently, the CDDIS has established a real-time streaming capability for GNSS data and products. Furthermore, enhancements to metadata describing the contents ofthe archive have been developed to facilitate data discovery. This poster will provide a review of the improvements in the system infrastructure that CDDIS has made over the past year for the geodetic community and describe future plans for the system.
International Laser Ranging Service (ILRS): Terms of Reference
NASA Technical Reports Server (NTRS)
Husson, Van; Noll, Carey
2000-01-01
The International Laser Ranging Service (ILRS) is an established Service within Section II , Advanced Space Technology, of the International Association of Geodesy (IAG). The primary objective of the ILRS is to provide a service to support, through Satellite and Lunar Laser Ranging data and related products, geodetic and geophysical research activities as well as International Earth Rotation Service (IERS) products important to the maintenance of an accurate International Terrestrial Reference Frame (ITRF). The service also develops the necessary standards/specifications and encourages international adherence to its conventions.
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas
2014-01-01
Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.
Amateur Radio on the International Space Station - Phase 2 Hardware System
NASA Technical Reports Server (NTRS)
Bauer, F.; McFadin, L.; Bruninga, B.; Watarikawa, H.
2003-01-01
The International Space Station (ISS) ham radio system has been on-orbit for over 3 years. Since its first use in November 2000, the first seven expedition crews and three Soyuz taxi crews have utilized the amateur radio station in the Functional Cargo Block (also referred to as the FGB or Zarya module) to talk to thousands of students in schools, to their families on Earth, and to amateur radio operators around the world. Early on, the Amateur Radio on the International Space Station (ARISS) international team devised a multi-phased hardware development approach for the ISS ham radio station. Three internal development Phases. Initial Phase 1, Mobile Radio Phase 2 and Permanently Mounted Phase 3 plus an externally mounted system, were proposed and agreed to by the ARISS team. The Phase 1 system hardware development which was started in 1996 has since been delivered to ISS. It is currently operational on 2 meters. The 70 cm system is expected to be installed and operated later this year. Since 2001, the ARISS international team have worked to bring the second generation ham system, called Phase 2, to flight qualification status. At this time, major portions of the Phase 2 hardware system have been delivered to ISS and will soon be installed and checked out. This paper intends to provide an overview of the Phase 1 system for background and then describe the capabilities of the Phase 2 radio system. It will also describe the current plans to finalize the Phase 1 and Phase 2 testing in Russia and outlines the plans to bring the Phase 2 hardware system to full operation.
Standardization for oxygen isotope ratio measurement - still an unsolved problem.
Kornexl; Werner; Gehre
1999-07-01
Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.
Test of simple fluid theories for the Lennard-Jones system
NASA Astrophysics Data System (ADS)
Malijevský, A.; Labik, S.
1988-03-01
A test is made of a new version of the reference-hypernetted chain approximation (RHNC) with minimized free energy proposed by Lado, Foiles and Ashcroft. An accurate relationship is used for the bridge function of the reference hard spheres. The calculated values of the compressibility factor and the internal energy are compared with simulation data, with results of the exponential approximation of Andersen et al., and with results of the Madden-Fitts approximation. The RHNC provides the most reliable results over wide ranges of reduced temperatures and densities.
Cargo Movement Operations System (CMOS) Software Test Plan. Final
1990-07-26
NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: STP-0002 PROGRAM OFFICE CONTROL NUMBER: DATA ITEM DISCREPANCY WORKSHEET CDRL NUMBER: A007-03 DATE: 07/26/90 ORIGINATOR NAME: John J.Brassil OFFICE SYMBOL: SAIC TELEPHONE NU4BER: 272-2999 SUBSTANTIVE: X EDITORIAL: PAGE NUMBER: 63 PARA NUMBER: Table 4.2.1.2 COMMENT OR RECOMMENDED CHANGE: Replace the reference to the Source and Destination STP paragraphs with a reference to the paragraph of the STP which tests the interface itself. RATIONALE: Each internal
Kuttner, Samuel; Bujila, Robert; Kortesniemi, Mika; Andersson, Henrik; Kull, Love; Østerås, Bjørn Helge; Thygesen, Jesper; Tarp, Ivanka Sojat
2013-03-01
Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Based on international references and medical physicists' practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.
Hamm, Jon; Sullivan, Kristie; Clippinger, Amy J; Strickland, Judy; Bell, Shannon; Bhhatarai, Barun; Blaauboer, Bas; Casey, Warren; Dorman, David; Forsby, Anna; Garcia-Reyero, Natàlia; Gehen, Sean; Graepel, Rabea; Hotchkiss, Jon; Lowit, Anna; Matheson, Joanna; Reaves, Elissa; Scarano, Louis; Sprankle, Catherine; Tunkel, Jay; Wilson, Dan; Xia, Menghang; Zhu, Hao; Allen, David
2017-06-01
Acute systemic toxicity testing provides the basis for hazard labeling and risk management of chemicals. A number of international efforts have been directed at identifying non-animal alternatives for in vivo acute systemic toxicity tests. A September 2015 workshop, Alternative Approaches for Identifying Acute Systemic Toxicity: Moving from Research to Regulatory Testing, reviewed the state-of-the-science of non-animal alternatives for this testing and explored ways to facilitate implementation of alternatives. Workshop attendees included representatives from international regulatory agencies, academia, nongovernmental organizations, and industry. Resources identified as necessary for meaningful progress in implementing alternatives included compiling and making available high-quality reference data, training on use and interpretation of in vitro and in silico approaches, and global harmonization of testing requirements. Attendees particularly noted the need to characterize variability in reference data to evaluate new approaches. They also noted the importance of understanding the mechanisms of acute toxicity, which could be facilitated by the development of adverse outcome pathways. Workshop breakout groups explored different approaches to reducing or replacing animal use for acute toxicity testing, with each group crafting a roadmap and strategy to accomplish near-term progress. The workshop steering committee has organized efforts to implement the recommendations of the workshop participants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hamm, Jon; Sullivan, Kristie; Clippinger, Amy J.; Strickland, Judy; Bell, Shannon; Bhhatarai, Barun; Blaauboer, Bas; Casey, Warren; Dorman, David; Forsby, Anna; Garcia-Reyero, Natàlia; Gehen, Sean; Graepel, Rabea; Hotchkiss, Jon; Lowit, Anna; Matheson, Joanna; Reaves, Elissa; Scarano, Louis; Sprankle, Catherine; Tunkel, Jay; Wilson, Dan; Xia, Menghang; Zhu, Hao; Allen, David
2017-01-01
Acute systemic toxicity testing provides the basis for hazard labeling and risk management of chemicals. A number of international efforts have been directed at identifying non-animal alternatives for in vivo acute systemic toxicity tests. A September 2015 workshop, Alternative Approaches for Identifying Acute Systemic Toxicity: Moving from Research to Regulatory Testing, reviewed the state-of-the-science of non-animal alternatives for this testing and explored ways to facilitate implementation of alternatives. Workshop attendees included representatives from international regulatory agencies, academia, nongovernmental organizations, and industry. Resources identified as necessary for meaningful progress in implementing alternatives included compiling and making available high-quality reference data, training on use and interpretation of in vitro and in silico approaches, and global harmonization of testing requirements. Attendees particularly noted the need to characterize variability in reference data to evaluate new approaches. They also noted the importance of understanding the mechanisms of acute toxicity, which could be facilitated by the development of adverse outcome pathways. Workshop breakout groups explored different approaches to reducing or replacing animal use for acute toxicity testing, with each group crafting a roadmap and strategy to accomplish near-term progress. The workshop steering committee has organized efforts to implement the recommendations of the workshop participants. PMID:28069485
Aquatic information and retrieval (AQUIRE) database system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, R.; Niemi, G.; Pilli, A.
The AQUIRE database system is one of the foremost international resources for finding aquatic toxicity information. Information in the system is organized around the concept of an 'aquatic toxicity test.' A toxicity test record contains information about the chemical, species, endpoint, endpoint concentrations, and test conditions under which the toxicity test was conducted. For the past 10 years aquatic literature has been reviewed and entered into the system. Currently, the AQUIRE database system contains data on more than 2,400 species, 160 endpoints, 5,000 chemicals, 6,000 references, and 104,000 toxicity tests.
ANOPP programmer's reference manual for the executive System. [aircraft noise prediction program
NASA Technical Reports Server (NTRS)
Gillian, R. E.; Brown, C. G.; Bartlett, R. W.; Baucom, P. H.
1977-01-01
Documentation for the Aircraft Noise Prediction Program as of release level 01/00/00 is presented in a manual designed for programmers having a need for understanding the internal design and logical concepts of the executive system software. Emphasis is placed on providing sufficient information to modify the system for enhancements or error correction. The ANOPP executive system includes software related to operating system interface, executive control, and data base management for the Aircraft Noise Prediction Program. It is written in Fortran IV for use on CDC Cyber series of computers.
Bhaskaran, Eswaran; Azhagarasan, N S; Miglani, Saket; Ilango, T; Krishna, G Phani; Gajapathi, B
2013-09-01
Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.
Rodrigues, Luciane Cristine Ribeiro; Juliani, Carmen Maria Casquel Monti
2015-01-01
To compare hospital indicators before and after implementing an Internal Bed Regulation Committee at a reference hospital. It is an quantitative, evaluation, exploratory, descriptive and cross-sectional research. The data was gathered from the hospital administrative reports for the period 2008-2013, provided by the Information Technology Center of the Complexo FAMEMA. The indicators improved after implementation of the Internal Bed Regulation Committee. The individuals involved in the process acknowledged the improvement. It is necessary to carry on the regulatory actions, especially in a comprehensive and complex healthcare system, such as the brazilian Sistema Único de Saúde.
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.
Jones, Graham R D; Jackson, Craig
2016-01-30
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhu, Yuanyuan; Yang, Chao; Weng, Mingjiao; Zhang, Yan; Yang, Chunhui; Jin, Yinji; Yang, Weiwei; He, Yan; Wu, Yiqi; Zhang, Yuhua; Wang, Guangyu; RajkumarEzakiel Redpath, Riju James; Zhang, Lei; Jin, Xiaoming; Liu, Ying; Sun, Yuchun; Ning, Ning; Qiao, Yu; Zhang, Fengmin; Li, Zhiwei; Wang, Tianzhen; Zhang, Yanqiao; Li, Xiaobo
2017-01-01
Numerous evidences indicate that aspirin usage causes a significant reduction in colorectal cancer. However, the molecular mechanisms about aspirin preventing colon cancer are largely unknown. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) is a most frequently used method to identify the target molecules regulated by certain compound. However, this method needs stable internal reference genes to analyze the expression change of the targets. In this study, the transcriptional stabilities of several traditional reference genes were evaluated in colon cancer cells treated with aspirin, and also, the suitable internal reference genes were screened by using a microarray and were further identified by using the geNorm and NormFinder softwares, and then were validated in more cell lines and xenografts. We have showed that three traditional internal reference genes, β-actin, GAPDH and α-tubulin, are not suitable for studying gene transcription in colon cancer cells treated with aspirin, and we have identified and validated TMEM208 and PQLC2 as the ideal internal reference genes for detecting the molecular targets of aspirin in colon cancer in vitro and in vivo. This study reveals stable internal reference genes for studying the target genes of aspirin in colon cancer, which will contribute to identify the molecular mechanism behind aspirin preventing colon cancer. PMID:28184026
Zhu, Yuanyuan; Yang, Chao; Weng, Mingjiao; Zhang, Yan; Yang, Chunhui; Jin, Yinji; Yang, Weiwei; He, Yan; Wu, Yiqi; Zhang, Yuhua; Wang, Guangyu; RajkumarEzakiel Redpath, Riju James; Zhang, Lei; Jin, Xiaoming; Liu, Ying; Sun, Yuchun; Ning, Ning; Qiao, Yu; Zhang, Fengmin; Li, Zhiwei; Wang, Tianzhen; Zhang, Yanqiao; Li, Xiaobo
2017-04-04
Numerous evidences indicate that aspirin usage causes a significant reduction in colorectal cancer. However, the molecular mechanisms about aspirin preventing colon cancer are largely unknown. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) is a most frequently used method to identify the target molecules regulated by certain compound. However, this method needs stable internal reference genes to analyze the expression change of the targets. In this study, the transcriptional stabilities of several traditional reference genes were evaluated in colon cancer cells treated with aspirin, and also, the suitable internal reference genes were screened by using a microarray and were further identified by using the geNorm and NormFinder softwares, and then were validated in more cell lines and xenografts. We have showed that three traditional internal reference genes, β-actin, GAPDH and α-tubulin, are not suitable for studying gene transcription in colon cancer cells treated with aspirin, and we have identified and validated TMEM208 and PQLC2 as the ideal internal reference genes for detecting the molecular targets of aspirin in colon cancer in vitro and in vivo. This study reveals stable internal reference genes for studying the target genes of aspirin in colon cancer, which will contribute to identify the molecular mechanism behind aspirin preventing colon cancer.
26 CFR 49.4264(d)-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 49.4264(d)-1 Section 49.4264(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES FACILITIES AND SERVICES EXCISE TAXES Transportation of Persons § 49.4264(d)-1 Cross...
NASA Technical Reports Server (NTRS)
Noll. Carey E.
2010-01-01
Since 1982. the Crustal Dynamics Data Information System (CDDIS) has supported the archive and distribution of geodetic data products acquired by the National Aeronautics and Space Administration (NASA) as well as national and international programs. The CDDIS provides easy, timely, and reliable access to a variety of data sets, products, and information about these data. These measurements. obtained from a global network of nearly 650 instruments at more than 400 distinct sites, include DORIS (Doppler Orbitography and Radiopositioning Integrated by Satellite), GNSS (Global Navigation Satellite System), SLR and LLR (Satellite and Lunar Laser Ranging), and VLBI (Very Long Baseline Interferometry). The CDDIS data system and its archive have become increasingly important to many national and international science communities, particularly several of the operational services within the International Association of Geodesy (IAG) and its observing system the Global Geodetic Observing System (GGOS), including the International DORIS Service (IDS), the International GNSS Service (IGS). the International Laser Ranging Service (ILRS), the International VLBI Service for Geodesy and Astrometry (IVS). and the International Earth rotation and Reference frame Service (IERS), Investigations resulting from the data and products available through the CDDIS support research in many aspects of Earth system science and global change. Each month, the CDDIS archives more than one million data and derived product files totaling over 90 Gbytes in volume. In turn. the global user community downloads nearly 1.2 TBytes (over 10.5 million files) of data and products from the CDDIS each month. The requirements of analysts have evolved since the start of the CDDIS; the specialized nature of the system accommodates the enhancements required to support diverse data sets and user needs. This paper discusses the CDDIS. including background information about the system and its. user communities. archive contents. available metadata, and future plans.
Reference States and Relative Values of Internal Energy, Enthalpy, and Entropy.
ERIC Educational Resources Information Center
Fredrickson, A. G.
1983-01-01
Discusses two reference states (pure chemical compounds and pure elements at specified condition of temperature and pressure) and the relation between these reference states for internal energy and enthalpy. Problem 5.11 from Modell and Reid's "Thermodynamics and its Applications" (p. 141) is used to apply the ideas discussed. (JN)
Stakeholders' Perceptions of IELTS as an Entry Requirement for Higher Education in the UK
ERIC Educational Resources Information Center
Hyatt, David
2013-01-01
This project explores stakeholders' perceptions of the role of the International English Language Testing System (IELTS) in the admissions processes of UK higher education (HE) institutions. The term "stakeholders" here refers to HE academic and administrative staff responsible for the acceptance of students whose first language is not…
48 CFR 752.229-70 - Federal, state and local taxes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... taxes. 752.229-70 Section 752.229-70 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL....229-70 Federal, state and local taxes. For contracts involving performance overseas the clauses prescribed in FAR 29.401-3 or 29.401-4 may be modified to specify that the taxes referred to are United...
The Interlibrary Loan Protocol: An OSI Solution to ILL Messaging.
ERIC Educational Resources Information Center
Turner, Fay
1990-01-01
Discusses the interlibrary loan (ILL) protocol, a standard based on the principles of the Open Systems Interconnection (OSI) Reference Model. Benefits derived from protocol use are described, the status of the protocol as an international standard is reviewed, and steps taken by the National Library of Canada to facilitate migration to an ILL…
The Cosmopolitan University: The Medium toward Global Citizenship and Justice
ERIC Educational Resources Information Center
George-Jackson, Casey E.
2010-01-01
This article promotes the idea of universities adopting cosmopolitanism as a way to manage the changing demands on the system of higher education in the USA, namely to improve the inclusion of international students, minority students and other historically underrepresented groups, often referred to as the "Other," which will in turn…
The Current SI Seen From the Perspective of the Proposed New SI
Taylor, Barry N.
2011-01-01
A revised International System of Units (SI) proposed by the International Committee for Weights and Measures is under consideration by the General Conference on Weights and Measures for eventual adoption. Widely recognized as a significant advance for both metrology and science, it is defined via statements that explicitly fix the numerical values of a selected set of seven reference constants when the values of these constants are expressed in certain specified units. At first sight this approach to defining a system of units appears to be quite different from that used to define the current SI. However, by showing how the definitions of the seven base units of the current SI also fix the numerical values of a set of seven reference constants (broadly interpreted) when the values of these constants are expressed in their coherent SI units, and how the definition of the current SI can be recast into the same form as that of the revised SI under consideration, we show that the revision is not as radical a departure from the current SI as it might initially seem. PMID:26989600
Microcomputer-controlled world time display for public area viewing
NASA Astrophysics Data System (ADS)
Yep, S.; Rashidian, M.
1982-05-01
The design, development, and implementation of a microcomputer-controlled world clock is discussed. The system, designated international Time Display System (ITDS), integrates a Geochron Calendar Map and a microcomputer-based digital display to automatically compensate for daylight savings time, leap year, and time zone differences. An in-depth technical description of the design and development of the electronic hardware, firmware, and software systems is provided. Reference material on the time zones, fabrication techniques, and electronic subsystems are also provided.
[Interpretation in the Danish health-care system].
Lund Hansen, Marianne Taulo; Nielsen, Signe Smith
2013-03-04
Communication between health professional and patient is central for treatment and patient safety in the health-care system. This systematic review examines the last ten years of specialist literature concerning interpretation in the Danish health-care system. Structural search in two databases, screening of references and recommended literature from two scientists led to identification of seven relevant articles. The review showed that professional interpreters were not used consistently when needed. Family members were also used as interpreters. These results were supported by international investigations.
The 1990 Reference Handbook: Earth Observing System
NASA Technical Reports Server (NTRS)
1990-01-01
An overview of the Earth Observing System (EOS) including goals and requirements is given. Its role in the U.S. Global Change Research Program and the International--Biosphere Program is addressed. The EOS mission requirements, science, fellowship program, data and information systems architecture, data policy, space measurement, and mission elements are presented along with the management of EOS. Descriptions of the facility instruments, instrument investigations, and interdisciplinary investigations are also present. The role of the National Oceanic and Atmospheric Administration in the mission is mentioned.
Helen M. Alexander
2012-01-01
The Fourth International Workshop on the Genetics of Host-Parasite Interactions in Forestry (July 31-August 5, 2011) included a session on âEcology and Evolutionary Biology of Resistance and Tolerance, Natural Systems.â Within this session, I gave a talk entitled âAn overview of ecological and evolutionary research on disease in ânaturalâ systemsâ that reviewed...
Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.
Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W
2016-02-26
Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.
INCOSE Systems Engineering Handbook v3.2: Improving the Process for SE Practitioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Douglas Hamelin; David D. Walden; Michael E. Krueger
2010-07-01
The INCOSE Systems Engineering Handbook is the official INCOSE reference document for understanding systems engineering (SE) methods and conducting SE activities. Over the years, the Handbook has evolved to accommodate advances in the SE discipline and now serves as the basis for the Certified Systems Engineering Professional (CSEP) exam. Due to its evolution, the Handbook had become somewhat disjointed in its treatment and presentation of SE topics and was not aligned with the latest version of International Organization for Standardization (ISO)/International Electrotechnical Commission (IEC) 15288:2008, Systems and Software Engineering. As a result, numerous inconsistencies were identified that could confuse practitionersmore » and directly impact the probability of success in passing the CSEP exam. Further, INCOSE leadership had previously submitted v3.1 of the Handbook to ISO/IEC for consideration as a Technical Report, but was told that the Handbook would have to be updated to conform with the terminology and structure of new ISO/IEC15288:2008, Systems and software engineering, prior to being considered. The revised INCOSE Systems Engineering Handbook v3.2 aligns with the structure and principles of ISO/IEC 15288:2008 and presents the generic SE life-cycle process steps in their entirety, without duplication or redundancy, in a single location within the text. As such, the revised Handbook v3.2 serves as a comprehensive instructional and reference manual for effectively understanding SE processes and conducting SE and better serves certification candidates preparing for the CSEP exam.« less
GTX Reference Vehicle Structural Verification Methods and Weight Summary
NASA Technical Reports Server (NTRS)
Hunter, J. E.; McCurdy, D. R.; Dunn, P. W.
2002-01-01
The design of a single-stage-to-orbit air breathing propulsion system requires the simultaneous development of a reference launch vehicle in order to achieve the optimal mission performance. Accordingly, for the GTX study a 300-lb payload reference vehicle was preliminary sized to a gross liftoff weight (GLOW) of 238,000 lb. A finite element model of the integrated vehicle/propulsion system was subjected to the trajectory environment and subsequently optimized for structural efficiency. This study involved the development of aerodynamic loads mapped to finite element models of the integrated system in order to assess vehicle margins of safety. Commercially available analysis codes were used in the process along with some internally developed spread-sheets and FORTRAN codes specific to the GTX geometry for mapping of thermal and pressure loads. A mass fraction of 0.20 for the integrated system dry weight has been the driver for a vehicle design consisting of state-of-the-art composite materials in order to meet the rigid weight requirements. This paper summarizes the methodology used for preliminary analyses and presents the current status of the weight optimization for the structural components of the integrated system.
GTX Reference Vehicle Structural Verification Methods and Weight Summary
NASA Technical Reports Server (NTRS)
Hunter, J. E.; McCurdy, D. R.; Dunn, P. W.
2002-01-01
The design of a single-stage-to-orbit air breathing propulsion system requires the simultaneous development of a reference launch vehicle in order to achieve the optimal mission performance. Accordingly, for the GTX study a 300-lb payload reference vehicle was preliminarily sized to a gross liftoff weight (GLOW) of 238,000 lb. A finite element model of the integrated vehicle/propulsion system was subjected to the trajectory environment and subsequently optimized for structural efficiency. This study involved the development of aerodynamic loads mapped to finite element models of the integrated system in order to assess vehicle margins of safety. Commercially available analysis codes were used in the process along with some internally developed spreadsheets and FORTRAN codes specific to the GTX geometry for mapping of thermal and pressure loads. A mass fraction of 0.20 for the integrated system dry weight has been the driver for a vehicle design consisting of state-of-the-art composite materials in order to meet the rigid weight requirements. This paper summarizes the methodology used for preliminary analyses and presents the current status of the weight optimization for the structural components of the integrated system.
Kleinnijenhuis, Michiel; Mollink, Jeroen; Lam, Wilfred W; Kinchesh, Paul; Khrapitchev, Alexandre A; Smart, Sean C; Jbabdi, Saad; Miller, Karla L
2018-02-01
To demonstrate how reference data affect the quantification of the apparent diffusion coefficient (ADC) in long diffusion time measurements with diffusion-weighted stimulated echo acquisition mode (DW-STEAM) measurements, and to present a modification to avoid contribution from crusher gradients in DW-STEAM. For DW-STEAM, reference measurements at long diffusion times have significant b 0 value, because b = 0 cannot be achieved in practice as a result of the need for signal spoiling. Two strategies for acquiring reference data over a range of diffusion times were considered: constant diffusion weighting (fixed-b 0 ) and constant gradient area (fixed-q 0 ). Fixed-b 0 and fixed-q 0 were compared using signal calculations for systems with one and two diffusion coefficients, and experimentally using data from postmortem human corpus callosum samples. Calculations of biexponential diffusion decay show that the ADC is underestimated for reference images with b > 0, which can induce an apparent time-dependence for fixed-q 0 . Restricted systems were also found to be affected. Experimentally, the exaggeration of the diffusion time-dependent effect under fixed-q 0 versus fixed-b 0 was in a range predicted theoretically, accounting for 62% (longitudinal) and 35% (radial) of the time dependence observed in white matter. Variation in the b-value of reference measurements in DW-STEAM can induce artificial diffusion time dependence in ADC, even in the absence of restriction. Magn Reson Med 79:952-959, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
International Relations: A Student's Guide to Reference Resources.
ERIC Educational Resources Information Center
Silvester, Elizabeth
Intended for students, this annotated bibliography describes reference materials in International Relations that may be found in either the McLennan or Law Library of McGill University. Scope includes political science, international law, and related areas in the social and behavioral sciences, but titles which relate to the foreign relations of a…
International reference preparations of typhoid vaccine
Melikova, E. N.; Lesnjak, S. V.
1967-01-01
International collaborative laboratory studies on the International Reference Preparations of Typhoid Vaccine have so far failed to provide data on which international units for these vaccines can be based. Further assays carried out using the active mouse protection test, with immunization by the subcutaneous, intraperitoneal or intravenous route, confirmed the findings by some workers that the International Reference Preparation of Typhoid Vaccine (Acetone-Inactivated) (vaccine K) was more effective than the International Reference Preparation of Typhoid Vaccine (Heat-Phenol-Inactivated) (vaccine L), and indicated that intraperitoneal immunization was the most promising method. Vaccine K, together with the material extracted by the acetone in the preparation of the vaccine, had a significantly lower effectiveness (at the 5% probability level) only when intraperitoneal immunization was used. The reasons for the differences found between the various vaccines and routes of immunization are discussed at length. It is suggested that challenge with a strain of Salmonella moscow instead of the strain of Salm. typhi used until now gives a true infection and forms the basis of a reliable method for the potency assay of typhoid vaccines. PMID:5301738
Contributions of satellite-determined gravity results in geodesy
NASA Technical Reports Server (NTRS)
Khan, M. A.
1974-01-01
Different forms of the theoretical gravity formula are summarized and methods of standardization of gravity anomalies obtained from satellite gravity and terrestrial gravity data are discussed in the context of three most commonly used reference figures, e.g., International Reference Ellipsoid, Reference Ellipsoid 1967, and Equilibrium Reference Ellipsoid. These methods are important in the comparison and combination of satellite gravity and gravimetric data as well as the integration of surface gravity data, collected with different objectives, in a single reference system. For ready reference, tables for such reductions are computed. Nature of the satellite gravity anomalies is examined to aid the geophysical and geodetic interpretation of these anomalies in terms of the tectonic features of the earth and the structure of the earth's crust and mantle. Computation of the Potsdam correction from satellite-determined geopotential is reviewed. The contribution of the satellite gravity results in decomposing the total observed gravity anomaly into components of geophysical interest is discussed. Recent work on the possible temporal variations in the geogravity field is briefly reviewed.
TIGO: a geodetic observatory for the improvement of the global reference frame
NASA Astrophysics Data System (ADS)
Schlueter, Wolfgang; Hase, Hayo; Boeer, Armin
1999-12-01
The Bundesamt fuer Kartographie und Geodaesie (BKG) will provide a major contribution to the improvement and maintenance of the global reference frames: ICRF (International Celestial Reference Frame), ITRF (International Terrestrial Reference Frame) with the operation of TIGO (Transportable Integrated Geodetic Observatory). TIGO is designed as a transportable geodetic observatory which consists of all relevant geodetic space techniques for a fundamental station (including VLBI, SLR, GPS). The transportability of the observatory enables to fill up gaps in the International Space Geodetic Network and to optimize the contribution to the global reference frames. TIGO should operate for a period of 2 to 3 years (at minimum) at one location. BKG is looking for a cooperation with countries willing to contribute to the ITRF and to support the operation of TIGO.
NASA Technical Reports Server (NTRS)
Havelund, Klaus
2014-01-01
We present a form of automaton, referred to as data automata, suited for monitoring sequences of data-carrying events, for example emitted by an executing software system. This form of automata allows states to be parameterized with data, forming named records, which are stored in an efficiently indexed data structure, a form of database. This very explicit approach differs from other automaton-based monitoring approaches. Data automata are also characterized by allowing transition conditions to refer to other parameterized states, and by allowing transitions sequences. The presented automaton concept is inspired by rule-based systems, especially the Rete algorithm, which is one of the well-established algorithms for executing rule-based systems. We present an optimized external DSL for data automata, as well as a comparable unoptimized internal DSL (API) in the Scala programming language, in order to compare the two solutions. An evaluation compares these two solutions to several other monitoring systems.
Advanced Life Support Research and Technology Development Metric
NASA Technical Reports Server (NTRS)
Hanford, A. J.
2004-01-01
The Metric is one of several measures employed by the NASA to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2004. The values are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. For Fiscal Year 2004, the Advanced Life Support Research and Technology Development Metric value is 2.03 for an Orbiting Research Facility and 1.62 for an Independent Exploration Mission.
Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.
Lo, Y C; Armbruster, David A
2012-04-01
Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.
Development of internal forest soil reference samples and testing of digestion methods
J.E. Hislop; J.W. Hornbeck; S.W. Bailey; R.A. Hallett
1998-01-01
Our research requires determinations of total elemental concentrations of forest soils. The lack of certified forest soil reference materials led us to develop internal reference samples. Samples were collected from three soil horizons (Oa, B, and C) at three locations having forested, acidic soils similar to those we commonly analyze. A shatterbox was used to...
Cantrell, Jennifer; Shelley, Donna
2009-12-17
Fax referral services that connect smokers to state quitlines have been implemented in 49 U.S. states and territories and promoted as a simple solution to improving smoker assistance in medical practice. This study is an in-depth examination of the systems-level changes needed to implement and sustain a fax referral program in primary care. The study involved implementation of a fax referral system paired with a chart stamp prompting providers to identify smoking patients, provide advice to quit and refer interested smokers to a state-based fax quitline. Three focus groups (n = 26) and eight key informant interviews were conducted with staff and physicians at two clinics after the intervention. We used the Chronic Care Model as a framework to analyze the data, examining how well the systems changes were implemented and the impact of these changes on care processes, and to develop recommendations for improvement. Physicians and staff described numerous benefits of the fax referral program for providers and patients but pointed out significant barriers to full implementation, including the time-consuming process of referring patients to the Quitline, substantial patient resistance, and limitations in information and care delivery systems for referring and tracking smokers. Respondents identified several strategies for improving integration, including simplification of the referral form, enhanced teamwork, formal assignment of responsibility for referrals, ongoing staff training and patient education. Improvements in Quitline feedback were needed to compensate for clinics' limited internal information systems for tracking smokers. Establishing sustainable linkages to quitline services in clinical sites requires knowledge of existing patterns of care and tailored organizational changes to ensure new systems are prioritized, easily integrated into current office routines, formally assigned to specific staff members, and supported by internal systems that ensure adequate tracking and follow up of smokers. Ongoing staff training and patient self-management techniques are also needed to ease the introduction of new programs and increase their acceptability to smokers.
Technologies for Refueling Spacecraft On-Orbit
NASA Technical Reports Server (NTRS)
Chato, David J.
2000-01-01
This paper discusses the current technologies for on-orbit refueling of spacecraft. The findings of 55 references are reviewed and summarized. Highlights include: (1) the Russian Progress system used by the International Space Station; (2) a flight demonstration of superfluid helium transfer; and (3) ground tests of large cryogenic systems. Key technologies discussed include vapor free liquid outflow, control of fluid inflow to prevent liquid venting, and quick disconnects for on-orbit mating of transfer lines.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
Developing a fatigue questionnaire for Chinese civil aviation pilots.
Dai, Jing; Luo, Min; Hu, Wendong; Ma, Jin; Wen, Zhihong
2018-03-23
To assess the fatigue risk is an important challenge in improving flight safety in aviation industry. The aim of this study was to develop a comprehensive fatigue risk management indicators system and a fatigue questionnaire for Chinese civil aviation pilots. Participants included 74 (all males) civil aviation pilots. They finished the questionnaire in 20 minutes before a flight mission. The estimation of internal consistency with Cronbach's α and Student's t test as well as Pearson's correlation analysis were the main statistical methods. The results revealed that the fatigue questionnaire had acceptable internal consistency reliability and construct validity; there were significant differences on fatigue scores between international and domestic flight pilots. And some international flight pilots, who had taken medications as a sleep aid, had worse sleep quality than those had not. The long-endurance flight across time zones caused significant differences in circadian rhythm. The fatigue questionnaire can be used to measure Chinese civil aviation pilots' fatigue, which provided a reference for fatigue risk management system to civil aviation pilots.
Experiences with the DSM-III in a psychiatric consultation/liaison service.
Larsen, F
1986-01-01
375 patients referred to consultation/liaison service at a general hospital from the neurological and internal medical department were diagnosed according to the DSM-III criteria for axis I and II. The sample represents all the patients referred from the two departments in a two year period. The phenomenological approach of the DSM-III and its reliability, is an advantage over older classification systems in the psychiatric consultation/liaison work. The system was easily applicable in this setting, leaving only 4 percent with "Diagnoses deferred" on both axes. From the consultation/liaison psychiatrist's point of view, special problems seemed to exist concerning the categories "Somatoform disorders" and "Psychological factors affecting physical condition", and the concepts of the axis II.
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
WHO expert committee on specifications for pharmaceutical preparations. Fortieth report.
2006-01-01
This report presents the recommendations of an international group of experts convened by the World Health Organization to consider matters concerning the quality assurance of pharmaceuticals and specifications for drug substances and dosage forms. The report is complemented by a number of annexes. These include: a list of available International Chemical Reference Substances and International Infrared Spectra; supplementary guidelines on good manufacturing practices for heating, ventilation and air-conditioning systems for non-sterile pharmaceutical dosage forms; updated supplementary guidelines on good manufacturing practices for the manufacture of herbal medicines; supplementary guidelines on good manufacturing practices for validation; good distribution practices for pharmaceutical products; a model quality assurance system for procurement agencies (recommendations for quality assurance systems focusing on prequalification of products and manufacturers, purchasing, storage and distribution of pharmaceutical products); multisource (generic) pharmaceutical products: guidelines on registration requirements to establish interchangeability; a proposal to waive in vivo bioequivalence requirements for WHO Model List of Essential Medicines immediate-release, solid oral dosage forms; and additional guidance for organizations performing in vivo bioequivalence studies.
Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan
2012-09-01
A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, D. R.; Emery, K. E.; Gueymard, C.
2002-05-01
This conference paper describes the American Society for Testing and Materials (ASTM), the International Electrotechnical Commission (IEC), and the International Standards Organization (ISO) standard solar terrestrial spectra (ASTM G-159, IEC-904-3, ISO 9845-1) provide standard spectra for photovoltaic performance applications. Modern terrestrial spectral radiation models and knowledge of atmospheric physics are applied to develop suggested revisions to update the reference spectra. We use a moderately complex radiative transfer model (SMARTS2) to produce the revised spectra. SMARTS2 has been validated against the complex MODTRAN radiative transfer code and spectral measurements. The model is proposed as an adjunct standard to reproduce the referencemore » spectra. The proposed spectra represent typical clear sky spectral conditions associated with sites representing reasonable photovoltaic energy production and weathering and durability climates. The proposed spectra are under consideration by ASTM.« less
Nilsen, Bente B; Yngve, Agneta; Sjöberg, Agneta; Moraeus, Lotta; Lissner, Lauren; Werner, Bo
2016-10-01
The study compared how four different growth references determined the prevalence of thinness and overweight, based on height and weight measurements from a nationally representative sample of Swedish children from seven to nine years of age. The height and weight measurements of 4518 Swedish schoolchildren aged seven to nine years were carried out in 2008 using a standardised protocol. The prevalence of different degrees of thinness and overweight was calculated using international growth references from the World Health Organization, the International Obesity Task Force and two Swedish growth references from Werner and Karlberg. Depending on which growth reference we used, the prevalence of different degrees of thinness varied from 7.5% to 16.9% for the boys and 6.9% to 13.7% for the girls, while the prevalence of overweight, including obesity and severe obesity, varied from 16.5% to 25.7% for the boys and 18.2 to 25.2% for the girls. There were also significant gender differences depending on the growth reference we used. Using four different growth references, two international and two Swedish, produced wide variations in the prevalence of thinness and overweight, together with significant gender differences. In the absence of a global definition, we need both national and international growth references. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.
2016-01-01
The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…
Forti, Tatiana; Souto, Aline da S S; do Nascimento, Carlos Roberto S; Nishikawa, Marilia M; Hubner, Marise T W; Sabagh, Fernanda P; Temporal, Rosane Maria; Rodrigues, Janaína M; da Silva, Manuela
2016-01-01
Considering the absence of standards for culture collections and more specifically for biological resource centers in the world, in addition to the absence of certified biological material in Brazil, this study aimed to evaluate a Fungal Collection from Fiocruz, as a producer of certified reference material and as Biological Resource Center (BRC). For this evaluation, a checklist based on the requirements of ABNT ISO GUIA34:2012 correlated with the ABNT NBR ISO/IEC17025:2005, was designed and applied. Complementing the implementation of the checklist, an internal audit was performed. An evaluation of this Collection as a BRC was also conducted following the requirements of the NIT-DICLA-061, the Brazilian internal standard from Inmetro, based on ABNT NBR ISO/IEC 17025:2005, ABNT ISO GUIA 34:2012 and OECD Best Practice Guidelines for BRCs. This was the first time that the NIT DICLA-061 was applied in a culture collection during an internal audit. The assessments enabled the proposal for the adequacy of this Collection to assure the implementation of the management system for their future accreditation by Inmetro as a certified reference material producer as well as its future accreditation as a Biological Resource Center according to the NIT-DICLA-061. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.
Ram, E; Marcus, O; Joubran, S; Abdo, B; Asal, N R
2013-12-01
Lack of published data. Absence of Ethnic specific data. Lack of focus on obesity prevention in Arab schools. First set of data on obesity for Arab children. Data will be used as reference data. Alert health/school official for intervention. Objective The objective is to produce the first set of obesity prevalence data and use the data as reference values of body mass index (BMI) trends for Arab children in Israel and compare with Jewish and international data. Methods A prevalence study was carried out in 2009 in which 4130 children aged 6-12, were selected from eight Arab sector schools representing the Nazareth Municipality. Height, weight and BMI measurements were obtained and presented by age, mean age, size, weight, gender and percentile. Appropriate epidemiological and statistical methods used for comparison. Results The obesity and overweight prevalence rates in Arab children by age ranges from 0% to 2.6% and 0% to 11.2%, respectively. Comparison with international and Jewish data revealed differences in almost all age groups but higher rates in Arabs, especially boys. Discussion The higher rates/trends in Arab children may be explained by more Arab women entering the workforce, increase in single-parent families and changes in food and physical activity environments. Conclusion Based on our data, we recommend either an ethnic-specific BMI reference curves and/or inclusion of Arab data in the Israeli data system. Research need to focus on reasons for the increase and interventions to reverse/slow the trend. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.
International Celestial Reference Frame (ICRF): mantenimiento y extensión
NASA Astrophysics Data System (ADS)
Ma, C.; Arias, E. F.; Eubanks, T.; Fey, A. L.; Gontier, A.-M.; Jacobs, C. S.; Sovers, O. J.; Archinal, B. A.; Charlot, P.
A partir de enero de 1998 el sistema de referencia celeste convencional está representado por el International Celestial Reference System (ICRS) y materializado a través de las coordenadas VLBI del conjunto de radiofuentes extragalácticas que conforman el International Celestial Reference Frame (ICRF). La primera realización del ICRF, fue elaborada en 1995 por un grupo de expertos designado por la IAU, la que encomendó al International Earth Rotation Service el mantenimiento del ICRS, del ICRF y del vínculo con marcos de referencia en otras frecuencias. Una primera extensión del ICRF se realizó entre abril y junio de 1999, con el objetivo primario de proveer posiciones de radiofuentes extragalácticas observadas a partir de julio de 1995 y de mejorar las posiciones de las fuentes ``candidatas" con la inclusión de observaciones adicionales. Objetivos secundarios fueron monitorear a las radiofuentes para verificar que siguen siendo adecuadas para realizar al ICRF y mejorar las técnicas de análisis de datos. Como resultado del nuevo análisis se obtuvo una solución a partir de la cual se construyó la primera extensión del ICRF, denominada ICRF - Ext.1. Ella representa al ICRS, sus fuentes de definición se mantienen con las mismas posiciones y errores que en la primera realización del ICRF; las demás radiofuentes tienen coordenadas mejor determinadas que en ICRF; el marco de referencia se densificó con el agregado de 59 nuevas radiofuentes.
26 CFR 56.6001-1 - Notice or regulations requiring records, statements, and special returns.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., statements, and special returns. 56.6001-1 Section 56.6001-1 Internal Revenue INTERNAL REVENUE SERVICE..., of the Code, by treating each reference to chapter 42 in § 53.6001-1 as a reference to chapter 41. (b) Cross references. See § 56.4911-6 for general information on records of lobbying expenditures. See §§ 56...
Rodrigues, Luciane Cristine Ribeiro; Juliani, Carmen Maria Casquel Monti
2015-01-01
Objective To compare hospital indicators before and after implementing an Internal Bed Regulation Committee at a reference hospital. Methods It is an quantitative, evaluation, exploratory, descriptive and cross-sectional research. The data was gathered from the hospital administrative reports for the period 2008-2013, provided by the Information Technology Center of the Complexo FAMEMA. Results The indicators improved after implementation of the Internal Bed Regulation Committee. Conclusion The individuals involved in the process acknowledged the improvement. It is necessary to carry on the regulatory actions, especially in a comprehensive and complex healthcare system, such as the brazilian Sistema Único de Saúde. PMID:25993075
Ziegeweid, Jeffrey R.; Silliker, R. Jason; Densmore, Brenda K.; Krahulik, Justin
2016-08-15
Continuously recording water-level streamgages in Rainy Lake and Namakan Reservoir are used to regulate water levels according to rule curves established in 2000 by the International Joint Commission; however, water levels at streamgages were referenced to a variety of vertical datums, confounding efforts to model the flow of water through the system, regulate water levels during periods of high inflow, and evaluate the effectiveness of the rule curves. In October 2014, the U.S. Geological Survey, Natural Resources Canada, International Joint Commission, and National Park Service began a joint field study with the goal of obtaining precise elevations referenced to a uniform vertical datum for all reference marks used to set water levels at streamgages throughout Rainy Lake and Namakan Reservoir. This report was prepared by the U.S. Geological Survey in cooperation with Natural Resources Canada, International Joint Commission, and National Park Service.Three field crews deployed Global Navigation Satellite System receivers statically over 16 reference marks colocated with active and discontinued water-level streamgages throughout Rainy River, Rainy Lake, Namakan Reservoir, and select tributaries of Rainy Lake and Namakan Reservoir. A Global Navigation Satellite System receiver also was deployed statically over a National Geodetic Survey cooperative base network control station for use as a quality-control reference mark. Satellite data were collected simultaneously during a 5-day period and processed independently by the U.S. Geological Survey and Natural Resources Canada to obtain accurate positioning and elevations for the 17 surveyed reference marks. Processed satellite data were used to convert published water levels to elevations above sea level referenced to the Canadian Geodetic Vertical Datum of 2013 in order to compare water-surface elevations referenced to a uniform vertical datum throughout the study area. In this report, an “offset” refers to the correction applied to published data from a particular streamgage to produce elevation data referenced to a specified vertical datum.Offsets were applied to water-level data from surveyed streamgages to further evaluate the accuracy and utility of updated reference mark elevations presented in this report. Daily mean water levels from active streamgages surveyed in this study were converted to water-surface elevations referenced to the Canadian Geodetic Vertical Datum of 2013. Graphical comparisons of water-surface elevations for streamgages in Namakan Reservoir, Rainy Lake, and selected rivers are presented (referencing the Canadian Geodetic Vertical Datum of 2013). Offsets presented in this report can be used in the evaluation of rule curves and in flood damage curves that fully assess the benefits of one regulation approach over another. In addition, offsets may be used to calibrate hydraulic models developed for four narrows that connect lakes of Namakan Reservoir, refine digital elevation models, and support modeling studies designed to assess the effects of rule curves on aquatic vegetation, benthic invertebrates, northern pike, and walleye.
NASA Astrophysics Data System (ADS)
Wziontek, Hartmut; Falk, Reinhard; Bonvalot, Sylvain; Rülke, Axel
2017-04-01
After about 10 years of successful joint operation by BGI and BKG, the International Database for Absolute Gravity Measurements "AGrav" (see references hereafter) was under a major revision. The outdated web interface was replaced by a responsive, high level web application framework based on Python and built on top of Pyramid. Functionality was added, like interactive time series plots or a report generator and the interactive map-based station overview was updated completely, comprising now clustering and the classification of stations. Furthermore, the database backend was migrated to PostgreSQL for better support of the application framework and long-term availability. As comparisons of absolute gravimeters (AG) become essential to realize a precise and uniform gravity standard, the database was extended to document the results on international and regional level, including those performed at monitoring stations equipped with SGs. By this it will be possible to link different AGs and to trace their equivalence back to the key comparisons under the auspices of International Committee for Weights and Measures (CIPM) as the best metrological realization of the absolute gravity standard. In this way the new AGrav database accommodates the demands of the new Global Absolute Gravity Reference System as recommended by the IAG Resolution No. 2 adopted in Prague 2015. The new database will be presented with focus on the new user interface and new functionality, calling all institutions involved in absolute gravimetry to participate and contribute with their information to built up a most complete picture of high precision absolute gravimetry and improve its visibility. A Digital Object Identifier (DOI) will be provided by BGI to contributors to give a better traceability and facilitate the referencing of their gravity surveys. Links and references: BGI mirror site : http://bgi.obs-mip.fr/data-products/Gravity-Databases/Absolute-Gravity-data/ BKG mirror site: http://agrav.bkg.bund.de/agrav-meta/ Wilmes, H., H. Wziontek, R. Falk, S. Bonvalot (2009). AGrav - the New Absolute Gravity Database and a Proposed Cooperation with the GGP Project. J. of Geodynamics, 48, pp. 305-309. doi:10.1016/j.jog.2009.09.035. Wziontek, H., H. Wilmes, S. Bonvalot (2011). AGrav: An international database for absolute gravity measurements. In Geodesy for Planet Earth (S. Kenyon at al. eds). IAG Symposia, 136, 1035-1040, Springer, Berlin. 2011. doi:10.1007/978-3-642-20338-1_130.
Time scales in the context of general relativity.
Guinot, Bernard
2011-10-28
Towards 1967, the accuracy of caesium frequency standards reached such a level that the relativistic effect could not be ignored anymore. Corrections began to be applied for the gravitational frequency shift and for distant time comparisons. However, these corrections were not applied to an explicit theoretical framework. Only in 1991 did the International Astronomical Union provide metrics (then improved in 2000) for a definition of space-time coordinates in reference systems centred at the barycentre of the Solar System and at the centre of mass of the Earth. In these systems, the temporal coordinates (coordinate times) can be realized on the basis of one of them, the International Atomic Time (TAI), which is itself a realized time scale. The definition and the role of TAI in this context will be recalled. There remain controversies regarding the name to be given to the unit of coordinate times and to other quantities appearing in the theory. However, the idea that astrometry and celestial mechanics should adopt the usual metrological rules is progressing, together with the use of the International System of Units, among astronomers.
The Perception of Malaysian ESL Tertiary Level Students on the IELTS Test
ERIC Educational Resources Information Center
Zahari, Dhiya Amalina; Dhayaalan, Jeremiah Dhayaalan Jackson
2016-01-01
Currently, the most acknowledged test to qualify for overseas universities is the IELTS test which is referred to as the International English Language Testing System. It is implemented as an accreditation tool and is believed to be a reputable and trustworthy tool of language competence by tertiary institutions which employ its use. Regardless of…
Total Quality Management (TQM): Group Dynamics Workshop
1990-05-15
interactions with other OSD decision-making bodies. " Remove barriers /facilitate implementation. " Direct action on unresolved process problems referred...TQM leadership. - Total Quality Management FUNCTIONS: * Translate goals to tangible internal initiatives. " Remove barriers . " Establish and...Quality Management FUNCTIONS: • Identify and remove barriers . " Develop practical process improvements. " Install solutions and measurement systems for
Teachers' Perception of Evaluation and Testing in Nigerian Secondary School System
ERIC Educational Resources Information Center
Oguzor, Nkasiobi Silas; Opara, Jacinta Agbarachi
2013-01-01
This study was aimed to find out from the teachers in Nigeria, their perception of the functionalism and their participation in the internal testing programme of secondary schools special reference to a state in southern Nigeria. A sample of 1,000 teachers was randomly stratified from the entire teachers' population of 6,000 in government-own…
Code of Federal Regulations, 2011 CFR
2011-07-01
... NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 Edition 126.15 NFPA 14, Standard for...-2959: ASTM F-1121, Standard Specification for International Shore Connections for Marine Fire Applications, 1987 Edition 126.15 National Fire Protection Association (NFPA), One Batterymarch Park, P.O. Box...
Code of Federal Regulations, 2012 CFR
2012-07-01
... NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 Edition 126.15 NFPA 14, Standard for...-2959: ASTM F-1121, Standard Specification for International Shore Connections for Marine Fire Applications, 1987 Edition 126.15 National Fire Protection Association (NFPA), One Batterymarch Park, P.O. Box...
ERIC Educational Resources Information Center
Lassnigg, Lorenz; Vogtenhuber, Stefan
2011-01-01
The empirical approach referred to in this article describes the relationship between education and training (ET) supply and employment in Austria; the use of the new ISCED (International Standard Classification of Education) fields of study variable makes this approach applicable abroad. The purpose is to explore a system that produces timely…
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mentioned in this section is in accordance with ITU-R M.540-2 (incorporated by reference, see § 80.7) as...-printing telegraphy with forward error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mentioned in this section is in accordance with ITU-R M.540-2 (incorporated by reference, see § 80.7) as...-printing telegraphy with forward error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mentioned in this section is in accordance with ITU-R M.540-2 (incorporated by reference, see § 80.7) as...-printing telegraphy with forward error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of...
The Ethics and Politics of the International Transfer of Educational Policy and Practice
ERIC Educational Resources Information Center
Bridges, David
2014-01-01
The focus of this paper is on a variety of practices associated with the transfer of educational policy and practice from one national education system to another--practices sometimes referred to as "policy borrowing". Its concern is with the ethical and political issues raised by these practices. In particular, it discusses concerns…
ERIC Educational Resources Information Center
Cai, Yuzhuo; Yang, Po; Lyytinen, Anu; Hölttä, Seppo
2015-01-01
China has recently launched a radical reform to transform over 600 regional universities into application and technology oriented institutions. The reform is a response to diverse labour market demands, regional economic development and the suboptimal structure of the higher education system, and uses international experiences as a reference.…
Modernization of Koesters interferometer and high accuracy calibration gauge blocks
NASA Astrophysics Data System (ADS)
França, R. S.; Silva, I. L. M.; Couceiro, I. B.; Torres, M. A. C.; Bessa, M. S.; Costa, P. A.; Oliveira, W., Jr.; Grieneisen, H. P. H.
2016-07-01
The Optical Metrology Division (Diopt) of Inmetro is responsible for maintaining the national reference of the length unit according to International System of Units (SI) definitions. The length unit is realized by interferometric techniques and is disseminated to the dimensional community through calibrations of gauge blocks. Calibration of large gauge blocks from 100 mm to 1000 mm has been performed by Diopt with a Koesters interferometer with reference to spectral lines of a krypton discharge lamp. Replacement of this lamp by frequency stabilized lasers, traceable now to the time and frequency scale, is described and the first results are reported.
Guidance of Nonlinear Nonminimum-Phase Dynamic Systems
NASA Technical Reports Server (NTRS)
Devasia, Santosh
1996-01-01
The research work has advanced the inversion-based guidance theory for: systems with non-hyperbolic internal dynamics; systems with parameter jumps; and systems where a redesign of the output trajectory is desired. A technique to achieve output tracking for nonminimum phase linear systems with non-hyperbolic and near non-hyperbolic internal dynamics was developed. This approach integrated stable inversion techniques, that achieve exact-tracking, with approximation techniques, that modify the internal dynamics to achieve desirable performance. Such modification of the internal dynamics was used (a) to remove non-hyperbolicity which is an obstruction to applying stable inversion techniques and (b) to reduce large preactuation times needed to apply stable inversion for near non-hyperbolic cases. The method was applied to an example helicopter hover control problem with near non-hyperbolic internal dynamics for illustrating the trade-off between exact tracking and reduction of preactuation time. Future work will extend these results to guidance of nonlinear non-hyperbolic systems. The exact output tracking problem for systems with parameter jumps was considered. Necessary and sufficient conditions were derived for the elimination of switching-introduced output transient. While previous works had studied this problem by developing a regulator that maintains exact tracking through parameter jumps (switches), such techniques are, however, only applicable to minimum-phase systems. In contrast, our approach is also applicable to nonminimum-phase systems and leads to bounded but possibly non-causal solutions. In addition, for the case when the reference trajectories are generated by an exosystem, we developed an exact-tracking controller which could be written in a feedback form. As in standard regulator theory, we also obtained a linear map from the states of the exosystem to the desired system state, which was defined via a matrix differential equation.
NASA Astrophysics Data System (ADS)
Pu, Fei; Yang, Bingye; Ke, Caihuan
2015-07-01
Accurate quantification of transcripts using quantitative real-time polymerase chain reaction (qPCR) depends on the identification of reliable reference genes for normalization. This study aimed to identify and validate seven reference genes, including actin-2 ( ACT-2), elongation factor 1 alpha ( EF-1α), elongation factor 1 beta ( EF-1β), glyceraldehyde-3-phosphate dehydrogenase ( GAPDH), ubiquitin ( UBQ), β-tubulin ( β-TUB), and 18S ribosomal RNA, from Crassostrea angulata, a valuable marine bivalve cultured worldwide. Transcript levels of the candidate reference genes were examined using qPCR analysis and showed differential expression patterns in the mantle, gill, adductor muscle, labial palp, visceral mass, hemolymph and gonad tissues. Quantitative data were analyzed using the geNorm software to assess the expression stability of the candidate reference genes, revealing that β-TUB and UBQ were the most stable genes. The commonly used GAPDH and 18S rRNA showed low stability, making them unsuitable candidates in this system. The expression pattern of the G protein β-subunit gene ( Gβ) across tissue types was also examined and normalized to the expression of each or both of UBQ and β-TUB as internal controls. This revealed consistent trends with all three normalization approaches, thus validating the reliability of UBQ and β-TUB as optimal internal controls. The study provides the first validated reference genes for accurate data normalization in transcript profiling in Crassostrea angulata, which will be indispensable for further functional genomics studies in this economically valuable marine bivalve.
State reference design and saturated control of doubly-fed induction generators under voltage dips
NASA Astrophysics Data System (ADS)
Tilli, Andrea; Conficoni, Christian; Hashemi, Ahmad
2017-04-01
In this paper, the stator/rotor currents control problem of doubly-fed induction generator under faulty line voltage is carried out. Common grid faults cause a steep decline in the line voltage profile, commonly denoted as voltage dip. This point is critical for such kind of machines, having their stator windings directly connected to the grid. In this respect, solid methodological nonlinear control theory arguments are exploited and applied to design a novel controller, whose main goal is to improve the system behaviour during voltage dips, endowing it with low voltage ride through capability, a fundamental feature required by modern Grid Codes. The proposed solution exploits both feedforward and feedback actions. The feedforward part relies on suitable reference trajectories for the system internal dynamics, which are designed to prevent large oscillations in the rotor currents and command voltages, excited by line perturbations. The feedback part uses state measurements and is designed according to Linear Matrix Inequalities (LMI) based saturated control techniques to further reduce oscillations, while explicitly accounting for the system constraints. Numerical simulations verify the benefits of the internal dynamics trajectory planning, and the saturated state feedback action, in crucially improving the Doubly-Fed Induction Machine response under severe grid faults.
NASA Technical Reports Server (NTRS)
Moore, J. V.
1976-01-01
The Attitude Control System for the IUE spacecraft is described. The basic mission objectives are stated and a sequential discussion of the mission is presented. Desired accuracy for each mission phase is noted and where applicable the onboard control mechanization is shown. Sensors and actuator systems utilized by the control algorithms are described. Finally, onboard software is discussed to a level necessary to understand the prime mission mode operation.
Superpower Crises in a Less Confrontational World: Results of an Experimental Simulation
1990-04-01
interteam communications via RAND’s electronic mail system for gaming purposes. 2 The "pilot runs" were designated Games Three and Four, and are referred... game , the impact of a changing real-world international context-a more benign image of the adversary and a less competitive superpower relationship...information overload they faced. Several believed that these problems were game artifacts (which they attributed to our use of the electronic mail system
Inflight redesign of the IUE attitude control system
NASA Technical Reports Server (NTRS)
Femiano, M. D.
1986-01-01
The one- and two-gyro system designs of the International Ultraviolet Explorer (IUE) attitude control system (ACS) are examined. The inertial reference assembly that provides the primary attitude reference for IUE consists of six rate sensors which are single-axis rate integrating gyros. The gyros operate in a pulse rebalanced mode that produces an output pulse for 0.01 arcsec of motion about the input axis. The functions of the fine error sensor, fine sun sensor (FSS), the IUE reaction wheels, the onboard computer, and the hold/slew algorithm are described. The use of the hold/slew algorithm to compute the control voltage for the ACS based on the Kalman filter is studied. A two-gyro system was incorporated into IUE following gyro failure. The procedures for establishing attitude control with the two-gyro design based on the FSS is analyzed. The performance of the two-gyro system is evaluated; it is observed that the pitch and yaw gyro control is 0.24 arcsec and the control is sufficient to permit extended periods of observation.
General equilibrium characteristics of a dual-lift helicopter system
NASA Technical Reports Server (NTRS)
Cicolani, L. S.; Kanning, G.
1986-01-01
The equilibrium characteristics of a dual-lift helicopter system are examined. The system consists of the cargo attached by cables to the endpoints of a spreader bar which is suspended by cables below two helicopters. Results are given for the orientation angles of the suspension system and its internal forces, and for the helicopter thrust vector requirements under general circumstances, including nonidentical helicopters, any accelerating or static equilibrium reference flight condition, any system heading relative to the flight direction, and any distribution of the load to the two helicopters. Optimum tether angles which minimize the sum of the required thrust magnitudes are also determined. The analysis does not consider the attitude degrees of freedom of the load and helicopters in detail, but assumes that these bodies are stable, and that their aerodynamic forces in equilibrium flight can be determined independently as functions of the reference trajectory. The ranges of these forces for sample helicopters and loads are examined and their effects on the equilibrium characteristics are given parametrically in the results.
The International DORIS Service (IDS) - Recent Developments in Preparation for ITRF2013
NASA Technical Reports Server (NTRS)
Willis, Pascal; Lemoine, Frank G.; Moreaux, Guilhem; Soudarin, Laurent; Ferrage, Pascale; Ries, John; Otten, Michiel; Saunier, Jerome; Noll, Carey E.; Biancale, Richard;
2014-01-01
The International DORIS Service (IDS) was created in 2003 under the umbrella of the International Association of Geodesy (IAG) to foster scientific research related to the French DORIS tracking system and to deliver scientific products, mostly related to the International Earth rotation and Reference systems Service (IERS). We first present some general background related to the DORIS system (current and planned satellites, current tracking network and expected evolution) and to the general IDS organization (from Data Centers, Analysis Centers and Combination Center). Then, we discuss some of the steps recently taken to prepare the IDS submission to ITRF2013 (combined weekly time series based on individual solutions from several Analysis Centers). In particular, recent results obtained from the Analysis Centers and the Combination Center show that improvements can still be made when updating physical models of some DORIS satellites, such as Envisat, Cryosat-2 or Jason-2. The DORIS contribution to ITRF2013 should also benefit from the larger number of ground observations collected by the last generation of DGXX receivers (first instrument being onboard Jason-2 satellite). In particular for polar motion, sub-millarcsecond accuracy seems now to be achievable. Weekly station positioning internal consistency also seems to be improved with a larger DORIS constellation.
ERIC Educational Resources Information Center
Fraser, Renee White; Shani, Hadasa
Intended as a companion piece to volume 2 in the Method Series, Environmental Health Planning (CE 024 230), this second of six volumes in the International Health Planning Reference Series is a combined literature review and annotated bibliography dealing with environmental factors in health planning for developing countries. The review identifies…
A biokinetic model for systemic nickel
Melo, Dunstana; Leggett, Richard Wayne
2017-01-01
The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni andmore » 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.« less
A biokinetic model for systemic nickel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melo, Dunstana; Leggett, Richard Wayne
The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni andmore » 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.« less
Schumann, Gerhard; Klauke, Rainer; Canalias, Francesca; Bossert-Reuther, Steffen; Franck, Paul F H; Gella, F-Javier; Jørgensen, Poul J; Kang, Dongchon; Lessinger, Jean-Marc; Panteghini, Mauro; Ceriotti, Ferruccio
2011-09-01
Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.
Implementation of standardization in clinical practice: not always an easy task.
Panteghini, Mauro
2012-02-29
As soon as a new reference measurement system is adopted, clinical validation of correctly calibrated commercial methods should take place. Tracing back the calibration of routine assays to a reference system can actually modify the relation of analyte results to existing reference intervals and decision limits and this may invalidate some of the clinical decision-making criteria currently used. To maintain the accumulated clinical experience, the quantitative relationship to the previous calibration system should be established and, if necessary, the clinical decision-making criteria should be adjusted accordingly. The implementation of standardization should take place in a concerted action of laboratorians, manufacturers, external quality assessment scheme organizers and clinicians. Dedicated meetings with manufacturers should be organized to discuss the process of assay recalibration and studies should be performed to obtain convincing evidence that the standardization works, improving result comparability. Another important issue relates to the surveillance of the performance of standardized assays through the organization of appropriate analytical internal and external quality controls. Last but not least, uncertainty of measurement that fits for this purpose must be defined across the entire traceability chain, starting with the available reference materials, extending through the manufacturers and their processes for assignment of calibrator values and ultimately to the final result reported to clinicians by laboratories.
Optical monitoring of QSO in the framework of the Gaia space mission
NASA Astrophysics Data System (ADS)
Taris, F.; Damljanovic, G.; Andrei, A.; Klotz, A.; Vachier, F.
2015-08-01
The Gaia astrometric mission of the European Space Agency has been launched the 19th December 2013. It will provide an astrometric catalogue of 500 000 extragalactic sources that could be the basis of a new optical reference frame. On the other hand, the current International Celestial Reference Frame (ICRF) is based on the observations of extragalactic sources at radio wavelength. The astrometric coordinates of sources in these two reference systems will have roughly the same uncertainty. It is then mandatory to observe a set of common targets at both optical and radio wavelength to link the ICRF with what could be called the GCRF (Gaia Celestial Reference Frame). We will show in this paper some results obtained with the TJO, Telescopi Juan Oro, from Observatori Astronomic del Montsec in Spain. It also presents some results obtained with the Lomb-Scargle and CLEAN algorithm methods applied to optical magnitude obtained with the TAROT telescopes.
EGR distribution and fluctuation probe based on CO.sub.2 measurements
Parks, II, James E; Partridge, Jr., William P; Yoo, Ji Hyung
2015-04-07
A diagnostic system having a single-port EGR probe and a method for using the same. The system includes a light source, an EGR probe, a detector and a processor. The light source may provide a combined light beam composed of light from a mid-infrared signal source and a mid-infrared reference source. The signal source may be centered at 4.2 .mu.m and the reference source may be centered at 3.8 .mu.m. The EGR probe may be a single-port probe with internal optics and a sampling chamber with two flow cells arranged along the light path in series. The optics may include a lens for focusing the light beam and a mirror for reflecting the light beam received from a pitch optical cable to a catch optical cable. The signal and reference sources are modulated at different frequencies, thereby allowing them to be separated and the signal normalized by the processor.
NASA Technical Reports Server (NTRS)
Piccolo, R.
1979-01-01
The methodology used for vehicle layout and component definition is described as well as techniques for system optimization and energy evaluation. The preliminary design is examined with particular attention given to body and structure; propulsion system; crash analysis and handling; internal combustion engine; DC motor separately excited; Ni-Zn battery; transmission; control system; vehicle auxiliarries; weight breakdown, and life cycle costs. Formulas are given for the quantification of energy consumption and results are compared with the reference vehicle.
NASA Astrophysics Data System (ADS)
Chapront, J.; Chapront-Touzé, M.; Francou, G.
1999-03-01
An analysis of Lunar Laser Ranging (LLR) observations from January 1972 till March 1998 is performed using the lunar theory ELP 2000-96 and the completed Moons' theory of the lunar libration. The LLR station coordinates, polar motion and Universal Time are provided by the International Earth Rotation Service (IERS). In Solution 1 the precession-nutation transformation is given by recent analytical theories, while in Solution 2 it is derived from the IERS daily corrections. Orbital and free libration parameters of the Moon, and coordinates of the reflectors are obtained in both cases. The position of the inertial mean ecliptic of J2000.0 with respect to the equator of the mean Celestial Ephemeris Pole (CEP) of J2000.0 (in Solution 1) and to the International Celestial Reference System (ICRS), the IERS celestial reference system, (in Solution 2) are fit. The position of the mean CEP equator of J2000.0 and of several dynamical reference planes and origins, with respect to ICRS, are derived from these fits (Fig. 1). The leading results are the following: 0farcs057 60+/- 0farcs000 20 (in the equator) for the separation of the origin of right ascensions in ICRS from the ascending node of the inertial mean ecliptic of J2000.0 on the reference plane of ICRS, -0farcs0460 +/- 0farcs0008 (in the ecliptic) for the separation of the latter point from the inertial dynamical mean equinox of J2000.0, -0farcs015 19+/- 0farcs000 35 (in the equator) for the separation of the inertial dynamical mean equinox of J2000.0 from the J2000.0 right ascension origin derived from IERS polar motion and Universal Time and from precise theories of precession-nutation, and 23degr26 arcmin21 farcs405 22+/- 0farcs000 07 for the inertial obliquity of J2000.0. A correction of -0farcs3437 +/- 0farcs0040 /cy to the IAU 1976 value of the precession constant is also obtained (the errors quoted are formal errors).
Initial conceptual design study of self-critical nuclear pumped laser systems
NASA Technical Reports Server (NTRS)
Rodgers, R. J.
1979-01-01
An analytical study of self-critical nuclear pumped laser system concepts was performed. Primary emphasis was placed on reactor concepts employing gaseous uranium hexafluoride (UF6) as the fissionable material. Relationships were developed between the key reactor design parameters including reactor power level, critical mass, neutron flux level, reactor size, operating pressure, and UF6 optical properties. The results were used to select a reference conceptual laser system configuration. In the reference configuration, the 3.2 m cubed lasing volume is surrounded by a graphite internal moderator and a region of heavy water. Results of neutronics calculations yield a critical mass of 4.9 U(235) in the form (235)UF6. The configuration appears capable of operating in a continuous steady-state mode. The average gas temperature in the core is 600 K and the UF6 partial pressure within the lasing volume is 0.34 atm.
Position of the station Borowiec in the Doppler observation campaign WEDOC 80
NASA Astrophysics Data System (ADS)
Pachelski, W.
The position of the Doppler antenna located at the Borowiec Observatory, Poland, is analyzed based on data gathered during the WEDOC 80 study and an earlier study in 1977. Among other findings, it is determined that biases of the reference system origin can be partially eliminated by transforming absolute coordinates of two or more stations into station-to-station vector components, and by determining the vector length while the system scale remains affected by broadcast ephemerides. The standard deviations of absolute coordinates are shown to represent only the internal accuracy of the solution, and are found to depend on the geometrical configuration between the station position and the satellite passes. It is shown that significant correlations between station coordinates in translocation or multilocation are due to the poor conditioning of design matrices with respect to the origin and orientation of the reference system.
SysML: A Language for Space System Engineering
NASA Astrophysics Data System (ADS)
Mazzini, S.; Strangapede, A.
2008-08-01
This paper presents the results of an ESA/ESTEC internal study, performed with the support of INTECS, about modeling languages to support Space System Engineering activities and processes, with special emphasis on system requirements identification and analysis. The study was focused on the assessment of dedicated UML profiles, their positioning alongside the system and software life cycles and associated methodologies. Requirements for a Space System Requirements Language were identified considering the ECSS-E-10 and ECSS-E_40 processes. The study has identified SysML as a very promising language, having as theoretical background the reference system processes defined by the ISO15288, as well as industrial practices.
The International Celestial Reference Frame (ICRF) and the Relationship Between Frames
NASA Technical Reports Server (NTRS)
Ma, Chopo
2000-01-01
The International Celestial Reference Frame (ICRF), a catalog of VLBI source positions, is now the basis for astrometry and geodesy. Its construction and extension/maintenance will be discussed as well as the relationship of the ICRF, ITRF, and EOP/nutation.
NASA Astrophysics Data System (ADS)
Amalia, A.; Gunawan, D.; Hardi, S. M.; Rachmawati, D.
2018-02-01
The Internal Quality Assurance System (in Indonesian: SPMI (Sistem Penjaminan Mutu Internal) is a systemic activity of quality assurance of higher education in Indonesia. SPMI should be done by all higher education or universities in Indonesia based on the Regulation of the Minister of Research, Technology and Higher Education of the Republic of Indonesia Number 62 of 2016. Implementation of SPMI must refer to the principle of SPMI that is independent, standardize, accurate, well planned and sustainable, documented and systematic. To assist the SPMI cycle properly, universities need a supporting software to monitor all the activities of SPMI. But in reality, many universities are not optimal in building this SPMI monitoring system. One of the obstacles is the determination of system requirements in support of SPMI principles is difficult to achieve. In this paper, we observe the initial phase of the engineering requirements elicitation. Unlike other methods that collect system requirements from users and stakeholders, we find the system requirements of the SPMI principles from SPMI guideline book. The result of this paper can be used as a choice in determining SPMI software requirements. This paper can also be used by developers and users to understand the scenario of SPMI so that could overcome the problems of understanding between this two parties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoffel, T.; Reda, I.
2013-05-01
The NREL Pyrheliometer Comparisons for 2012 (NPC-2012) were held at the Solar Radiation Research Laboratory in Golden, Colorado, from September 24 through October 5 for the purpose of transferring the World Radiometric Reference (WRR) to participating instrument. Twenty scientists and engineers operated 32 absolute cavity radiometers and 18 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky direct normal irradiance during the comparisons. The transfer standard group of reference radiometers for NPC-2012 consisted of four NREL radiometers with direct traceability to the WRR, having participated in the Eleventh International Pyrheliometer Comparisons (IPC-XI) hosted by the World Radiation Center in the fall ofmore » 2010. As the result of NPC-2012, each participating absolute cavity radiometer was assigned a new WRR transfer factor, computed as the reference irradiance computed by the transfer standard group divided by the observed irradiance from the participating radiometer. The performance of the transfer standard group during NPC-2012 was consistent with previous comparisons, including IPC-XI. The measurement performance of the transfer standard group allowed the transfer of the WRR to each participating radiometer with an estimated uncertainty of +/- 0.33% with respect to the International System of Units.« less
Challenges faced by international nurses when migrating: an integrative literature review.
Pung, L-X; Goh, Y-S
2017-03-01
Results from this literature review were used to identify the challenges faced by international nurses in their host countries following migration. The increasing strain of nursing shortages in the healthcare system has led to the recruitment of international nurses among many countries. However, following migration, international nurses are faced with challenges that may result in poor integration with their host countries. Using Cooper's five stages for integrative research reviews, a literature search was conducted across seven databases using a PRISMA search strategy. Additional manual searches were also conducted on the end-references of the retrieved articles. The authors then independently reviewed the selected articles using the Joanna Briggs Institute appraisal form to extract and generate the themes for the review. Twenty-four articles were selected for the review. The themes generated included: (i) difficulty orientating; (ii) a longing for what is missing; (iii) professional development and devaluing; (iv) communication barriers; (v) discrimination and marginalization; (vi) personal and professional differences; and (vii) a meaningful support system. By identifying the challenges faced by international nurses, interventions that ensure equal treatment (e.g. multifaceted transition programmes and culturally sensitive 'buddy' systems) can be implemented to help international nurses adapt to their new environments. Adequate communication can be achieved by encouraging international nurses to speak English and learn the colloquial language and non-verbal behaviours used by native nurses. With good integration international nurses may be able to reach their full career potential as professional nurses in their host countries. The adaptation process is a dynamic process that requires effort from both international and native nurses. Thus, any strategies that are developed and implemented must be multifaceted. © 2016 International Council of Nurses.
ERIC Educational Resources Information Center
Miller, Frank W.; Loeding, Deborah Voigt
1989-01-01
Discussion of technological developments in library reference services focuses on contributions of the H. W. Wilson Company and highlights CD-ROM technology. Topics discussed include online access; menu-driven systems; CD-ROM hardware and software concerns; user response to CD-ROM; quality control of databases; pricing considerations; and future…
Learning on the Move: A Reassessment of Mobility through the Lens of Bateson's Learning Theory
ERIC Educational Resources Information Center
Janand, Anne; Notais, Amélie
2018-01-01
Purpose: This paper aims to explore the types of learning engendered by internal mobility (IM) by referring to the principles elaborated by Bateson (1972). Design/methodology/approach: A qualitative methodology is followed with interviews among 50 professionals working at four large French firms. Findings: A system of classification for IM is…
ERIC Educational Resources Information Center
Sava, Simona Lidia; Shah, S. Y.
2015-01-01
Validation of prior learning (VPL), also referred to as recognition, validation and accreditation of prior learning (RVA), is becoming an increasingly important political issue at both European and international levels. In 2012, the European Council, the UNESCO Institute for Lifelong Learning (UIL) and the Organisation for Economic Co-operation…
The International GPS Network for Charting the Evolving Global Reference Frame
NASA Technical Reports Server (NTRS)
Zumberge, J. F.; Heflin, M. B.; Lindqwister, U. J.; Neilan, R. E.; Watkins, M. M.
1995-01-01
The Telecommunications and Engineering Division of Caltech's Jet Propulsion Laboratory is funded by the National Aeronautics and Space Administration to play a variety of roles in applying the Global Positioning System (GPS) to geodesy and geodynamics. Among these are the operation of dozens of globally-distributed, permanently-operating Earth fixed GPS stations. This, and other applications are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joerissen, G.; Zuend, H.
From international nuclear industries fair; Basel, Switzerland (16 Oct 1972). The probability and the consequences of an aircraft crash on a nuclear power plant incorporating a light water reactor are estimated considering the probabilities of an aircraft strike, missile penetration through walls and damage of structures and systems important for safety. The estimated risks are presented in a Farmer diagram and compared with tolerable risk limits. (6 references) (auth)
Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin
2016-03-01
Quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma has become the standard of care in the management of HIV-infected patients. There are several commercially available assays that have been implemented for the detection of HIV-1 RNA in plasma. Here, the new Hologic Aptima® HIV-1 Quant Dx assay (Aptima HIV) was compared to the Roche COBAS® TaqMan® HIV-1 Test v2.0 for use with the High Pure System (HPS/CTM). The performance characteristics of the assays were assessed using commercially available HIV reference panels, dilution of the WHO 3rd International HIV-1 RNA International Standard (WHO-IS) and plasma from clinical specimens. Assay performance was determined by linear regression, Deming correlation analysis and Bland-Altman analysis. Testing of HIV-1 reference panels revealed excellent agreement. The 61 clinical specimens quantified in both assays were linearly associated and strongly correlated. The Aptima HIV assay offers performance comparable to that of the HPS/CTM assay and, as it is run on a fully automated platform, a significantly improved workflow.
Publications of the JPL Solar Thermal Power Systems Project, 1976 to 1983
NASA Technical Reports Server (NTRS)
Gray, V. (Compiler); Marsh, C. (Compiler); Panda, P. (Compiler)
1984-01-01
The bibliographical listings in this publication are documentation products associated with the solar thermal power system project carried out by the Jet Propulsion Laboratory from 1976 to 1983. Documents listed are categorized as conference and journal papers, JPL external reports, JPL internal reports, or contractor reports. Alphabetical listings by title were used in the bibliography itself to facilitate location of the document by subject. Two indexes are included for ease of reference: one, an author index; the other, a topical index.
Publications of the JPL Solar Thermal Power Systems Project 1976 Through 1985
NASA Technical Reports Server (NTRS)
Panda, P. (Compiler); Gray, V. (Compiler); Marsh, C. (Compiler)
1985-01-01
Bibliographical listings are documentation products associated with the Solar Thermal Power Systems Project carried out by the Jet Propulsion Laboratory from 1976 to 1986. Documents are categorized as conference and journal papers, JPL external reports, JPL internal reports, or contractor reports (i.e., deliverable documents produced under contract to JPL). Alphabetical listings by titles are used in the bibliography itself to facilitate location of the document by subject. Two indexes are included for ease of reference; an author index; and a topical index.
The 1991 EOS reference handbook
NASA Technical Reports Server (NTRS)
Dokken, David (Editor)
1991-01-01
The following topics are covered: (1) The Global Change Research Program; (2) The Earth Observing System (EOS) goal and objectives; (3) primary EOS mission requirements; (4) EOS science; (5) EOS Data and Information System (EOSDIS) architecture; (6) data policy; (7) international cooperation; (8) plans and status; (9) the role of the National Oceanic and Atmospheric Administration; (10) The Global Fellowship Program; (11) management of EOS; (12) mission elements; (13) EOS instruments; (14) interdisciplinary science investigations; (15) points of contact; and (16) acronyms and abbreviations.
Integrating home-based medication therapy management (MTM) services in a health system.
Reidt, Shannon; Holtan, Haley; Stender, Jennifer; Salvatore, Toni; Thompson, Bruce
2016-01-01
To describe the integration of home-based Medication Therapy Management (MTM) into the ambulatory care infrastructure of a large urban health system and to discuss the outcomes of this service. Minnesota from September 2012 to December 2013. The health system has more than 50 primary care and specialty clinics. Eighteen credentialed MTM pharmacists are located in 16 different primary care and specialty settings, with the greatest number of pharmacists providing services in the internal medicine clinic. Home-based MTM was promoted throughout the clinics within the health system. Physicians, advanced practice providers, nurses, and pharmacists could refer patients to receive MTM in their homes. A home visit had the components of a clinic-based visit and was documented in the electronic health record (EHR); however, providing the service in the home allowed for a more direct assessment of environmental factors affecting medication use. Number of home MTM referrals, reason for referral and type of referring provider, number and type of medication-related problems (MRPs). In the first 15 months, 74 home visits were provided to 53 patients. Sixty-six percent of the patients were referred from the Internal Medicine Clinic. Referrals were also received from the senior care, coordinated care, and psychiatry clinics. Approximately 50% of referrals were made by physicians. More referrals (23%) were made by pharmacists compared with advanced practice providers, who made 21% of referrals. The top 3 reasons for referral were: nonadherence, transportation barriers, and the need for medication reconciliation with a home care nurse. Patients had a median of 3 MRPs with the most common (40%) MRP related to compliance. Home-based MTM is feasibly delivered within the ambulatory care infrastructure of a health system with sufficient provider engagement as demonstrated by referrals to the service. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Coplen, Tyler B.
2010-01-01
Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.
Evolution and resilience of the nuclear nonproliferation regime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pregenzer, Arian L.
2014-05-09
This paper introduces the concept of systems resilience as a new framework for thinking about the future of the nonproliferation regime. Resilience refers to the ability of a system to maintain its vital functions in the face of continuous and unpredictable change. First, I make the case that the nonproliferation regime can be viewed as a complex system. Next, I discuss key themes from the literature on systems resilience and apply them to the nonproliferation system: the difference between resilience and stability; the need for evolution to maintain function; the importance of functional diversity; and the concept of the adaptivemore » cycle. I show that most existing nonproliferation strategies are aimed at stability rather than resilience and that the current nonproliferation system may be over-constrained by the cumulative evolution of strategies. According to the literature on systems resilience, this increases its vulnerability to collapse. I argue that the resilience of the nonproliferation system can be enhanced by increasing international participation in setting the nonproliferation agenda, developing general international response capabilities, focusing on non-coercive approaches to decreasing demand, and applying systems thinking more rigorously to nonproliferation.« less
The Portuguese generic medicines market: a policy analysis
Simoens, Steven
2008-01-01
Objectives: This study aims to conduct a descriptive analysis of the policy environment surrounding the generic medicines retail market in Portugal. The policy analysis focuses on supply-side measures (i.e. market access, pricing, reference-pricing and reimbursement of generic medicines) and demand-side measures (i.e. incentives for physicians to prescribe, for pharmacists to dispense and for patients to use generic medicines). Methods: The policy analysis was based on an international literature review. Also, a simulation exercise was carried out to compute potential savings from substituting generic for originator medicines in Portugal using IMS Health data. Results: Portugal has developed a successful generic medicines market by increasing reimbursement of generic medicines (until October 2005), by introducing a reference-pricing system, by encouraging physicians to prescribe by international non-proprietary name (INN), and by allowing generic substitution by pharmacists. However, the development of the generic medicines market has been hindered by the existence of copies, pricing regulation, certain features of the reference-pricing system, weak incentives for physicians to prescribe generic medicines and a financial disincentive for pharmacists to dispense generic medicines. Increased generic substitution would be expected to reduce public expenditure on originator medicines by 45%. Conclusions: The development of the Portuguese generic medicines market has mainly been fuelled by supply-side measures. To support the further expansion of the market, policy makers need to strengthen demand-side measures inciting physicians to prescribe, pharmacists to dispense and patients to use generic medicines. PMID:25152781
Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M
2006-08-31
International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.
The Global Geodetic Observing System: Recent Activities and Accomplishments
NASA Astrophysics Data System (ADS)
Gross, R. S.
2017-12-01
The Global Geodetic Observing System (GGOS) of the International Association of Geodesy (IAG) provides the basis on which future advances in geosciences can be built. By considering the Earth system as a whole (including the geosphere, hydrosphere, cryosphere, atmosphere and biosphere), monitoring Earth system components and their interactions by geodetic techniques and studying them from the geodetic point of view, the geodetic community provides the global geosciences community with a powerful tool consisting mainly of high-quality services, standards and references, and theoretical and observational innovations. The mission of GGOS is: (a) to provide the observations needed to monitor, map and understand changes in the Earth's shape, rotation and mass distribution; (b) to provide the global frame of reference that is the fundamental backbone for measuring and consistently interpreting key global change processes and for many other scientific and societal applications; and (c) to benefit science and society by providing the foundation upon which advances in Earth and planetary system science and applications are built. The goals of GGOS are: (1) to be the primary source for all global geodetic information and expertise serving society and Earth system science; (2) to actively promote, sustain, improve, and evolve the integrated global geodetic infrastructure needed to meet Earth science and societal requirements; (3) to coordinate with the international geodetic services that are the main source of key parameters and products needed to realize a stable global frame of reference and to observe and study changes in the dynamic Earth system; (4) to communicate and advocate the benefits of GGOS to user communities, policy makers, funding organizations, and society. In order to accomplish its mission and goals, GGOS depends on the IAG Services, Commissions, and Inter-Commission Committees. The Services provide the infrastructure and products on which all contributions of GGOS are based. The IAG Commissions and Inter-Commission Committees provide expertise and support for the scientific development within GGOS. In summary, GGOS is IAG's central interface to the scientific community and to society in general. Recent activities and accomplishments of the Global Geodetic Observing System will be presented.
ERIC Educational Resources Information Center
Leach, Jamie; Howe, Nina; DeHart, Ganie
2017-01-01
The present study investigated children's internal state language during play with their sibling and friend across early and middle childhood. Specifically, the category type of internal state language (e.g., cognitions and goals), referent (e.g., own and other), and associations with children's birth order were examined. A total of 65 (T1: Time…
Thermal design and turbidity sensor for autonomous bacterial growth measurements in spaceflight.
van Benthem, Roel; Krooneman, Janneke; de Grave, Wubbo; Hammenga-Dorenbos, Hilma
2009-04-01
For application of biological air filters in manned spacecraft, research on bacterial growth is carried out under microgravity conditions. For the BIOFILTER experiment, flown in 2005 on FOTON M2, eight turbidity sensors to measure the growth rate of the bacterium Xanthobacter autotrophicus GJ10 were used. Also thermal management provisions were implemented to control the internal temperature. The design and performance of the BIOFILTER equipment as well as results of the biological ground reference experiments performed in 2006 are discussed. High-performance thermal (vacuum) insulation (lambda= 0.7 mW/mK) and phase change material were implemented, keeping the BIOFILTER internal temperature below 16 degrees C during the 4-day integration period between transport and launch. After launch, in microgravity, the growth of X. autotrophicus GJ10 was successfully triggered by a temperature increase by using an internal heater to 26 degrees C. Although the operation of the sensor electronics was not fully satisfying, the bacterial growth was measured with the sensors, revealing growth rates between 0.046 and 0.077 h(-1) in microgravity, that is, approximately 1.5-2.5 times slower than routinely measured on Earth under optimal laboratory conditions. For the ground-reference experiments the equipment box, containing the eight sensors, was placed on a random positioning machine performing random rotations at 0.5 degrees /min (settling compensation) and 90 degrees /min (microgravity simulation) while the environment was controlled, accurately repeating the BIOFILTER internal temperature profile. Despite the rotation speed differences, growth rates of 0.115 h(-1) were confirmed by both the ground reference experiments. Biological interpretation of the measurements is, however, compromised owing to poor mixing and other unknown physical and biological phenomena that need to be addressed for further space experiments using these kinds of systems.
The International Geomagnetic Reference Field: the twelfth generation
NASA Astrophysics Data System (ADS)
Thebault, Erwan; Finlay, Christopher; The IGRF Working Group
2015-04-01
The IGRF is an internationally-agreed reference model of the Earth's magnetic field produced under the auspices of the International Association of Geomagnetism and Aeronomy. The IGRF-12 is the latest update of this well-known model which is used each year by many thousands of users for both industrial and scientific purposes. In October 2014, ten institutions worldwide have made contributions to the IGRF. These models were evaluated and the twelfth generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2014. In this presentation, we will report on the IGRF activities, briefly describe the candidate models, summarize the evaluation of models performed by different independent teams, show how the IGRF-12 models were calculated and finally discuss some of the main magnetic features of this new model.
Multispectral scanner flight model (F-1) radiometric calibration and alignment handbook
NASA Technical Reports Server (NTRS)
1981-01-01
This handbook on the calibration of the MSS-D flight model (F-1) provides both the relevant data and a summary description of how the data were obtained for the system radiometric calibration, system relative spectral response, and the filter response characteristics for all 24 channels of the four band MSS-D F-1 scanner. The calibration test procedure and resulting test data required to establish the reference light levels of the MSS-D internal calibration system are discussed. The final set of data ("nominal" calibration wedges for all 24 channels) for the internal calibration system is given. The system relative spectral response measurements for all 24 channels of MSS-D F-1 are included. These data are the spectral response of the complete scanner, which are the composite of the spectral responses of the scan mirror primary and secondary telescope mirrors, fiber optics, optical filters, and detectors. Unit level test data on the measurements of the individual channel optical transmission filters are provided. Measured performance is compared to specification values.
Nishigori, Hiroshi; Otani, Takashi; Plint, Simon; Uchino, Minako; Ban, Nobutaro
2009-05-01
Although medical students have increasingly more opportunities to participate in international electives, their experiences are usually unstructured and the literature referring to their learning outcomes, educational environment, and assessment is scanty. This study was undertaken to clarify qualitatively what students learn from their international electives. We carried out semi-structured individual interviews with 15 Japanese students studying clinical medicine in British medical schools and six British students studying in Japanese medical schools. The thematic synthesis method was used in analysing the transcribed data and triangulation by multiple researchers was used to achieve higher reliability. The main learning outcomes identified were skills in history taking and physical examination with clinical reasoning and in management of diseases rarely seen in the students' own countries; awareness of clinical ethics and merits and demerits of different systems of healthcare and medical education; sensitivity to issues in doctor-patient relationships and work ethics; enhancement of cultural competence; and personal development. Most learning outcomes of international electives are culture- or system-dependent. Students achieved outcomes related closely to medical professionalism, mainly through reflection. International electives may give students opportunities to learn both professionalism and cultural competence.
Belete, Tamrat; Crowley, Erin; Bird, Patrick; Gensic, Joseph; Wallace, F Morgan
2014-10-01
The performances of two DuPont BAX System PCR assays for detecting Salmonella on a variety of low-moisture soy ingredients were evaluated against the U. S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method or the International Organization for Standardization (ISO) 6579 reference method. These evaluations were conducted as a single laboratory validation at an ISO 17025 accredited third-party laboratory. Validations were conducted on five soy ingredients: isolated soy protein (ISP), soy fiber, fluid soy lecithin, deoiled soy lecithin, and soy nuggets, using a paired-study design. The ISP was analyzed as both 25- and 375-g composite test portions, whereas all other sample matrices were analyzed as 375-g composite test portions. To evaluate 25-g test portions of ISP, the test material was inoculated using Salmonella enterica subsp. enterica serovar Mbandaka (Q Laboratories isolate 11031.1). Salmonella enterica subsp. enterica serovar Tennessee (Q Laboratories isolate 11031.3) was used for all other trials. For each trial of the method comparison, 25 samples were analyzed for each matrix: 5 uninoculated controls and 20 samples inoculated at low levels (0.2 to 2 CFU per test portion) that were targeted to achieve fractionally positive results (25 to 75%). Using McNemar's chi-square analysis, no significant difference at P ≥ 0.05 (χ(2) ≤ 3.84) was observed between the number of positives obtained by the BAX System and the reference methods for all five test matrices evaluated. These studies indicate that the BAX System PCR assays, in combination with the single buffered peptone water primary enrichment and subsequent brain heart infusion regrowth step, demonstrate equivalent sensitivity and robustness compared with the FDA BAM and ISO reference methods for both 25- and 375-g composite samples. Moreover, there was no observed reduction of sensitivity in the larger 375-g composite samples for all five matrices.
Comparison of A-SMGCS Requirements with Observed Performance of an Integrated Airport CNS System
NASA Technical Reports Server (NTRS)
Young, Steven D.
1997-01-01
The International Civil Aviation Organization (ICAO) has recently drafted a reference document describing the operational requirements for Advanced Surface Movement Guidance and Control Systems (A-SMGCS). During the summer of 1997, NASA, the FAA, industry, and academia partners demonstrated a holistic system approach that has the potential to meet many of the proposed A-SMGCS requirements. An assessment of the field tested system and data resulting from the field testing is presented to determine its compliance with A-SMGCS requirements. In those areas where compliance was not demonstrated, a recommendation is presented suggesting further research or a modification of the system architecture.
Kulaga, Zbigniew; Litwin, Mieczysław; Tkaczyk, Marcin; Rózdzyńska, Agnieszka; Barwicka, Katarzyna; Grajda, Aneta; Swiader, Anna; Gurzkowska, Beata; Napieralska, Ewelina; Pan, Huiqi
2010-03-04
The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used.
2010-01-01
Background The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Methods Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Results Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. Conclusions In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used. PMID:20199693
Rigorous Combination of GNSS and VLBI: How it Improves Earth Orientation and Reference Frames
NASA Astrophysics Data System (ADS)
Lambert, S. B.; Richard, J. Y.; Bizouard, C.; Becker, O.
2017-12-01
Current reference series (C04) of the International Earth Rotation and Reference Systems Service (IERS) are produced by a weighted combination of Earth orientation parameters (EOP) time series built up by combination centers of each technique (VLBI, GNSS, Laser ranging, DORIS). In the future, we plan to derive EOP from a rigorous combination of the normal equation systems of the four techniques.We present here the results of a rigorous combination of VLBI and GNSS pre-reduced, constraint-free, normal equations with the DYNAMO geodetic analysis software package developed and maintained by the French GRGS (Groupe de Recherche en GeÌodeÌsie Spatiale). The used normal equations are those produced separately by the IVS and IGS combination centers to which we apply our own minimal constraints.We address the usefulness of such a method with respect to the classical, a posteriori, combination method, and we show whether EOP determinations are improved.Especially, we implement external validations of the EOP series based on comparison with geophysical excitation and examination of the covariance matrices. Finally, we address the potential of the technique for the next generation celestial reference frames, which are currently determined by VLBI only.
International reference ionosphere 1990
NASA Technical Reports Server (NTRS)
Bilitza, Dieter; Rawer, K.; Bossy, L.; Kutiev, I.; Oyama, K.-I.; Leitinger, R.; Kazimirovsky, E.
1990-01-01
The International Reference Ionosphere 1990 (IRI-90) is described. IRI described monthly averages of the electron density, electron temperature, ion temperature, and ion composition in the altitude range from 50 to 1000 km for magnetically quiet conditions in the non-auroral ionosphere. The most important improvements and new developments are summarized.
Cameron, A; Ewen, M; Ross-Degnan, D; Ball, D; Laing, R
2009-01-17
WHO and Health Action International (HAI) have developed a standardised method for surveying medicine prices, availability, affordability, and price components in low-income and middle-income countries. Here, we present a secondary analysis of medicine availability in 45 national and subnational surveys done using the WHO/HAI methodology. Data from 45 WHO/HAI surveys in 36 countries were adjusted for inflation or deflation and purchasing power parity. International reference prices from open international procurements for generic products were used as comparators. Results are presented for 15 medicines included in at least 80% of surveys and four individual medicines. Average public sector availability of generic medicines ranged from 29.4% to 54.4% across WHO regions. Median government procurement prices for 15 generic medicines were 1.11 times corresponding international reference prices, although purchasing efficiency ranged from 0.09 to 5.37 times international reference prices. Low procurement prices did not always translate into low patient prices. Private sector patients paid 9-25 times international reference prices for lowest-priced generic products and over 20 times international reference prices for originator products across WHO regions. Treatments for acute and chronic illness were largely unaffordable in many countries. In the private sector, wholesale mark-ups ranged from 2% to 380%, whereas retail mark-ups ranged from 10% to 552%. In countries where value added tax was applied to medicines, the amount charged varied from 4% to 15%. Overall, public and private sector prices for originator and generic medicines were substantially higher than would be expected if purchasing and distribution were efficient and mark-ups were reasonable. Policy options such as promoting generic medicines and alternative financing mechanisms are needed to increase availability, reduce prices, and improve affordability.
Zainol, Murizal; Stoute, Julia; Almeida, Gabriela M.; Rapp, Alexander; Bowman, Karen J.; Jones, George D. D.
2009-01-01
The Comet assay (CA) is a sensitive/simple measure of genotoxicity. However, many features of CA contribute variability. To minimize these, we have introduced internal standard materials consisting of ‘reference’ cells which have their DNA substituted with BrdU. Using a fluorescent anti-BrdU antibody, plus an additional barrier filter, comets derived from these cells could be readily distinguished from the ‘test’-cell comets, present in the same gel. In experiments to evaluate the reference cell comets as external and internal standards, the reference and test cells were present in separate gels on the same slide or mixed together in the same gel, respectively, before their co-exposure to X-irradiation. Using the reference cell comets as internal standards led to substantial reductions in the coefficient of variation (CoV) for intra- and inter-experimental measures of comet formation and DNA damage repair; only minor reductions in CoV were noted when the reference and test cell comets were in separate gels. These studies indicate that differences between individual gels appreciably contribute to CA variation. Further studies using the reference cells as internal standards allowed greater significance to be obtained between groups of replicate samples. Ultimately, we anticipate that development will deliver robust quality assurance materials for CA. PMID:19828597
Next Generation Trusted Radiation Identification System (NG-TRIS).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flynn, Adam J.; Amai, Wendy A.; Merkle, Peter Benedict
2010-05-01
The original Trusted Radiation Identification System (TRIS) was developed from 1999-2001, featuring information barrier technology to collect gamma radiation template measurements useful for arms control regime operations. The first TRIS design relied upon a multichannel analyzer (MCA) that was external to the protected volume of the system enclosure, undesirable from a system security perspective. An internal complex programmable logic device (CPLD) contained data which was not subject to software authentication. Physical authentication of the TRIS instrument case was performed by a sensitive but slow eddy-current inspection method. This paper describes progress to date for the Next Generation TRIS (NG-TRIS), whichmore » improves the TRIS design. We have incorporated the MCA internal to the trusted system volume, achieved full authentication of CPLD data, and have devised rapid methods to authenticate the system enclosure and weld seals of the NG-TRIS enclosure. For a complete discussion of the TRIS system and components upon which NG-TRIS is based, the reader is directed to the comprehensive user's manual and system reference of Seager, et al.« less
Davit, Barbara; Braddy, April C; Conner, Dale P; Yu, Lawrence X
2013-10-01
The objective of this article is to discuss the similarities and differences among bioequivalence approaches used by international regulatory authorities when reviewing applications for marketing new generic drug products which are systemically active and intended for oral administration. We focused on the 13 jurisdictions and organizations participating in the International Generic Drug Regulators Pilot. These are Australia, Brazil, Canada, China, Chinese Taipei, the European Medicines Association, Japan, Mexico, Singapore, South Korea, Switzerland, the USA, and the World Health Organization. We began with a comparison of how the various jurisdictions and organizations define a generic product and its corresponding reference product. We then compared the following bioequivalence approaches: recommended bioequivalence study designs, method of pharmacokinetic calculations and bioequivalence acceptance limits, recommendations for modifying bioequivalence study designs and limits for highly variable drugs and narrow therapeutic index drugs, provisions for waiving bioequivalence study requirements (granting biowaivers), and implementation of the Biopharmaceutics Classification System. We observed that, overall, there are more similarities than differences in bioequivalence approaches among the regulatory authorities surveyed.
The environmental zero-point problem in evolutionary reaction norm modeling.
Ergon, Rolf
2018-04-01
There is a potential problem in present quantitative genetics evolutionary modeling based on reaction norms. Such models are state-space models, where the multivariate breeder's equation in some form is used as the state equation that propagates the population state forward in time. These models use the implicit assumption of a constant reference environment, in many cases set to zero. This zero-point is often the environment a population is adapted to, that is, where the expected geometric mean fitness is maximized. Such environmental reference values follow from the state of the population system, and they are thus population properties. The environment the population is adapted to, is, in other words, an internal population property, independent of the external environment. It is only when the external environment coincides with the internal reference environment, or vice versa, that the population is adapted to the current environment. This is formally a result of state-space modeling theory, which is an important theoretical basis for evolutionary modeling. The potential zero-point problem is present in all types of reaction norm models, parametrized as well as function-valued, and the problem does not disappear when the reference environment is set to zero. As the environmental reference values are population characteristics, they ought to be modeled as such. Whether such characteristics are evolvable is an open question, but considering the complexity of evolutionary processes, such evolvability cannot be excluded without good arguments. As a straightforward solution, I propose to model the reference values as evolvable mean traits in their own right, in addition to other reaction norm traits. However, solutions based on an evolvable G matrix are also possible.
NASA Astrophysics Data System (ADS)
Bachmann, Sabine; Thaller, Daniela; Roggenbuck, Ole; Lösler, Michael; Messerschmitt, Linda
2016-07-01
Every few years the International Terrestrial Reference System (ITRS) Center of the International Earth Rotation and Reference Systems Service (IERS) decides to generate a new version of the International Terrestrial Reference Frame (ITRF). For the upcoming ITRF2014 the official contribution of the International VLBI Service for Geodesy and Astrometry (IVS) comprises 5796 combined sessions in SINEX file format from 1979.6 to 2015.0 containing 158 stations, overall. Nine AC contributions were included in the combination process, using five different software packages. Station coordinate time series of the combined solution show an overall repeatability of 3.3 mm for the north, 4.3 mm for the east and 7.5 mm for the height component over all stations. The minimum repeatabilities are 1.5 mm for north, 2.1 mm for east and 2.9 mm for height. One of the important differences between the IVS contribution to the ITRF2014 and the routine IVS combination is the omission of the correction for non-tidal atmospheric pressure loading (NTAL). Comparisons between the amplitudes of the annual signals derived by the VLBI observations and the annual signals from an NTAL model show that for some stations, NTAL has a high impact on station height variation. For other stations, the effect of NTAL is low. Occasionally other loading effects have a higher influence (e.g. continental water storage loading). External comparisons of the scale parameter between the VTRF2014 (a TRF based on combined VLBI solutions), DTRF2008 (DGFI-TUM realization of ITRS) and ITRF2008 revealed a significant difference in the scale. A scale difference of 0.11 ppb (i.e. 0.7 mm on the Earth's surface) has been detected between the VTRF2014 and the DTRF2008, and a scale difference of 0.44 ppb (i.e. 2.8 mm on the Earth's surface) between the VTRF2014 and ITRF2008. Internal comparisons between the EOP of the combined solution and the individual solutions from the AC contributions show a WRMS in X- and Y-Pole between 40 and 100 \\upmu as and for dUT1 between 5 and 15 \\upmu s. External comparisons with respect to the IERS-08-C04 series show a WRMS of 132 and 143 \\upmu as for X- and Y-Pole, respectively, and 13 \\upmu s for dUT.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-03-26
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-01-01
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800
[Effectiveness of incorporating a quality management system].
Seki, Akira; Hankins, Raleigh W; Miya, Tetsumasa
2010-01-01
In 2003, the ISO 15189 international standardization program on the quality and competence of the clinical reference laboratory was introduced. To date, 46 facilities have committed themselves to providing a higher level of medical service by incorporating a quality management system (QMS) and acquiring accreditation. QMS is defined as "setting up a policy and goals pertaining to quality, and adopting an appropriate system," and is a scheme that includes all managerial and technical factors that can affect test results. Regarding the Health Sciences Research Institute Group, 4 facilities have previously received the accreditation described above, but in the process of implementing the QMS, a number of problems have been identified. Here, we report on the effectiveness of adopting such a QMS based on the results of employee questionnaires, internal audits, customer complaint analyses, and external audits by the Japan Accreditation Board for Conformity Assessment (JAB), the official inspection body for accreditation.
Zhao, Ran; Chen, Ren; Zhang, Bing; Ma, Ying; Qin, Xia; Hu, Zhi
2015-08-01
Monitoring and evaluation (M&E) for human immunodeficiency virus (HIV) capacity building has become a significant step for HIV prevention and control. The M&E system strengthening tool published by the United Nations Joint Programme on HIV/AIDS (UNAIDS) was intended to be the most authoritative assessment tool internationally. Facing the fact that the M&E system in China did not function at an optimum level, we considered taking the international standards for reference. By linguistic validating and different stages' discussions and revisions, we came up with the Chinese version of the capacity diagnosis tool with at least 12 components and tested its validity and reliability. The tool turned out to have a sufficiently linguistic validation and proved to be a scientific and feasible instrument which was suitable for China's national conditions.
The Smartphone-Based Offline Indoor Location Competition at IPIN 2016: Analysis and Future Work.
Torres-Sospedra, Joaquín; Jiménez, Antonio R; Knauth, Stefan; Moreira, Adriano; Beer, Yair; Fetzer, Toni; Ta, Viet-Cuong; Montoliu, Raul; Seco, Fernando; Mendoza-Silva, Germán M; Belmonte, Oscar; Koukofikis, Athanasios; Nicolau, Maria João; Costa, António; Meneses, Filipe; Ebner, Frank; Deinzer, Frank; Vaufreydaz, Dominique; Dao, Trung-Kien; Castelli, Eric
2017-03-10
This paper presents the analysis and discussion of the off-site localization competition track, which took place during the Seventh International Conference on Indoor Positioning and Indoor Navigation (IPIN 2016). Five international teams proposed different strategies for smartphone-based indoor positioning using the same reference data. The competitors were provided with several smartphone-collected signal datasets, some of which were used for training (known trajectories), and others for evaluating (unknown trajectories). The competition permits a coherent evaluation method of the competitors' estimations, where inside information to fine-tune their systems is not offered, and thus provides, in our opinion, a good starting point to introduce a fair comparison between the smartphone-based systems found in the literature. The methodology, experience, feedback from competitors and future working lines are described.
On a New Theory of the System of Reference
NASA Astrophysics Data System (ADS)
Kalanov, Temur Z.
2003-04-01
A new theory of the system of reference is suggested. It represents the new point of view which has arisen from the critical analysis of the foundations of physics (in particular, the theory of relativity and quantum mechanics), mathematics, cosmology and philosophy. The main idea following from the analysis is that the correct concept of system of reference represents a key to comprehension of many basic logic errors which are in modern physics. The starting point of the theory is represented by the philosophical (dialectical materialistic) principles, in particular, the gnosiological principle. (The gnosiological principle is briefly formulated as follows. The purpose of a science is to know the laws of the Nature. The law is a form of scientific knowledge of the essence and the phenomenon. The essence is the internal basis of the phenomenon, and the phenomenon is the manifestation of the essence. Human practice is a basis of knowledge and a criterion of truth). These principles lead to the following statements. (1) The reality is the dialectical unity of the opposites: the objective reality and the non-objective (subjective) reality. (2) The system mankind + means of knowledge belongs to the subjective reality and is called system of reference. In this wide sense, the system of reference is the universal informational gnostic basis (i.e. the system consisting of natural objects and processes, of constructed devices and instruments, of sum of human knowledge and skills) created and used by mankind for the purpose of knowledge of the world. (3) The opposites are bounds of each other. Hence, the principle of objectivity of the physical laws is formulated as follows: the objective physical laws must not contain mentions of system of reference (in particular, references to procedure of measurement or of calculation). (4) The main informational property of the unitary system set of researches physical objects + system of reference is that the system of reference determines (measures, calculates) the parameters of the subsystem set of researched physical objects (for example, the coordinates x_M, y_M, zM of the object M); the parameters characterize the system of reference (for example, the system of coordinates). (5) The main gnostic property of the unitary system set of researches physical objects + system of reference is that the system of reference defines (formulates) the physical laws (i.e. creates the theories); the physical laws characterize the system of reference. (6) The parameters which take on values independently of existence of the researched physical objects characterize the system of reference. For example, the clock C, a part of the system of reference S, determines (but it does not measure!) the time t_C; the time tC characterizes the clock C. If all clocks have been synchronized, the universal time tS characterizes the system of reference S. (7) Researched physical object M and a clock are mutually independent objects. Hence, the coordinates x_M, y_M, zM and the time tS are mutually independent parameters. (8) The informational one-to-one correspondence between motion of object M and physical clock-process in clock is established (is defined) by man. For example, it has a form: dx_M/dtS ≡ v_x_M. Consequences: (a) information about the world is an ordered information because the system of reference S is an ordered and universal system. This information is an objective one if it does not depend on a system of reference; (b) mathematical operations on physical quantities with the coordinates and with the time are allowed by the laws of logic because the set of researches physical objects + system of reference is a unitary system; (c) the principle of existence and of transformation of coordinates: there are no coordinates and no transformation of coordinates in general, and there exist the coordinates x_M, y_M, zM and transformation of the coordinates x_M, y_M, zM of the object M only; (d) the special and general theories of relativity are an erroneous theories because their foundations, firstly, do not satisfy the principle of objectivity of the physical laws, secondly, they contradict the principle of transformation of coordinates and, thirdly, they assume mutual dependence between the researched physical object and a clock (i.e. between coordinates and time); (e) quantum mechanics does not satisfy the principle of objectivity of the physical laws.
NASA Astrophysics Data System (ADS)
Siejka, Zbigniew
2017-09-01
GNSS systems are currently the basic tools for determination of the highest precision station coordinates (e.g. basic control network stations or stations used in the networks for geodynamic studies) as well as for land, maritime and air navigation. All of these tasks are carried out using active, large scale, satellite geodetic networks which are complex, intelligent teleinformatic systems offering post processing services along with corrections delivered in real-time for kinematic measurements. Many countries in the world, also in Europe, have built their own multifunctional networks and enhance them with their own GNSS augmentation systems. Nowadays however, in the era of international integration, there is a necessity to consider collective actions in order to build a unified system, covering e.g. the whole Europe or at least some of its regions. Such actions have already been undertaken in many regions of the world. In Europe such an example is the development for EUPOS which consists of active national networks built in central eastern European countries. So far experience and research show, that the critical areas for connecting these networks are border areas, in which the positioning accuracy decreases (Krzeszowski and Bosy, 2011). This study attempts to evaluate the border area compatibility of Polish ASG-EUPOS (European Position Determination System) reference stations and Ukrainian GeoTerrace system reference stations in the context of their future incorporation into the EUPOS. The two networks analyzed in work feature similar hardware parameters. In the ASG-EUPOS reference stations network, during the analyzed period, 2 stations (WLDW and CHEL) used only one system (GPS), while, in the GeoTerrace network, all the stations were equipped with both GPS and GLONASS receivers. The ASG EUPOS reference station network (95.6%) has its average completeness greater by about 6% when compared to the GeoTerrace network (89.8%).
Heo, Ji Haeng; Rascati, Karen L; Lee, Eui-Kyung
2017-05-01
The reference pricing system (RPS) establishes reference prices within interchangeable reference groupings. For drugs priced higher than the reference point, patients pay the difference between the reference price and the total price. To predict potential changes in prescription ingredient costs and co-payment rates after implementation of an RPS in South Korea. Korean National Health Insurance claims data were used as a baseline to develop possible RPS models. Five components of a potential RPS policy were varied: reference groupings, reference pricing methods, co-pay reduction programs, manufacturer price reductions, and increased drug substitutions. The potential changes for prescription ingredient costs and co-payment rates were predicted for the various scenarios. It was predicted that transferring the difference (total price minus reference price) from the insurer to patients would reduce ingredient costs from 1.4% to 22.8% for the third-party payer (government), but patient co-payment rates would increase from a baseline of 20.4% to 22.0% using chemical groupings and to 25.0% using therapeutic groupings. Savings rates in prescription ingredient costs (government and patient combined) were predicted to range from 1.6% to 13.7% depending on various scenarios. Although the co-payment rate would increase, a 15% price reduction by manufacturers coupled with a substitution rate of 30% would result in a decrease in the co-payment amount (change in absolute dollars vs. change in rates). Our models predicted that the implementation of RPS in South Korea would lead to savings in ingredient costs for the third-party payer and co-payments for patients with potential scenarios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Citations of Brazilian physical therapy journals in national publications.
Teixeira, Renan K C; Yamaki, Vitor N; Botelho, Nara M; Teixeira, Renato C
2014-01-01
Quotations in Brazilian journals are mainly obtained from national articles (articles from Brazilian journals); thus, it is essential to determine how frequently these articles reference Brazilian journals. This study sought to verify how frequently national papers are cited in the references of three Brazilian physical therapy journals. All references for articles published in Fisioterapia em Movimento, Fisioterapia e Pesquisa and Revista Brasileira de Fisioterapia between 2010 and 2012 were evaluated. In particular, the numbers of national articles and international articles (articles from international journals) cited in these references were determined. A total of 13,009 references cited by 456 articles were analyzed, and 2,924 (22.47%) of the cited works were national articles. There were no significant differences among the three examined years. A total of 36 (7.89%) articles did not cite national articles, whereas 65 (13.25%) articles cited more national articles than international articles. On average, 22.47% of the works cited by the evaluated articles were national articles. No significant differences were detected among the three analyzed years.
Xi, Bo; Zong, Xin'nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y T; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Romdhane, Habiba Ben; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; El Ati, Jalila; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2016-01-26
Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations. © 2015 American Heart Association, Inc.
Xi, Bo; Zong, Xin’nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M.; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y.T.; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K.; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Ben Romdhane, Habiba; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; Ati, Jalila El; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2015-01-01
Background Several distributions of country-specific blood pressure (BP) percentiles by sex, age and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limit international comparisons of prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents using seven nationally representative data (China, India, Iran, Korea, Poland, Tunisia and USA). Methods and Results Data on BP for 52,636 non-overweight children and adolescents aged 6–19 years were obtained from seven large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and USA. BP values were obtained with certified mercury sphygmomanometers in all seven countries, using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th and 99th) by age and height were estimated using the Generalized Additive Model for Location Scale and Shape (GAMLSS) model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. Compared to BP level of the 90th and 95th percentiles of the U.S. Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower while diastolic BP was similar. Conclusions These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help identify hypertensive youths in diverse populations. PMID:26671979
Phase Synchronization for the Mid-Frequency Square Kilometre Array Telescope
NASA Astrophysics Data System (ADS)
Schediwy, Sascha; Gozzard, David; Stobie, Simon; Gravestock, Charles; Whitaker, Richard; Alachkar, Bassem; Malan, Sias; Boven, Paul; Grainge, Keith
2018-01-01
The Square Kilometre Array (SKA) project is an international effort to build the world’s most sensitive radio telescope operating in the 50 MHz to 14 GHz frequency range. Construction of the SKA has been divided into phases, with the first phase (SKA1) accounting for the first 10% of the telescope's receiving capacity. During SKA1, a low-frequency aperture array comprising over a hundred thousand individual dipole antenna elements will be constructed in Western Australia (SKA1-low), while an array of 197 parabolic-dish antennas, incorporating the 64 dishes of MeerKAT, will be constructed in South Africa (SKA1-mid).Radio telescope arrays such as the SKA require phase-coherent reference signals to be transmitted to each antenna site in the array. In the case of the SKA1-mid, these reference signals will be generated at a central site and transmitted to the antenna sites via fiber-optic cables up to 175 km in length. Environmental perturbations affect the optical path length of the fiber and act to degrade the phase stability of the reference signals received at the antennas, which has the ultimate effect of reducing the fidelity and dynamic range of the data.Since 2011, researchers at the University of Western Australia (UWA) have led the development of an actively-stabilized phase-synchronization system designed specifically to meet the scientific needs and technical challenges of the SKA telescope. Recently this system has been select as the official phase synchronization system for the SKA1-mid telescope. The system is an evolution of Atacama Large Millimeter Array’s distributed ‘photonic local oscillator system’, incorporating key advances made by the international frequency metrology community over the last decade, as well as novel innovations developed by UWA researchers.In this presentation I will describe the technical details of the system; outline how the system's performance was tested using metrology techniques in a laboratory setting, on 186 km of overhead fibre at the South African SKA site, and verified using existing astronomical radio interferometers; and how the system can enhance the astronomical performance of the SKA1-mid telescope.
NASA Astrophysics Data System (ADS)
Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.
2011-01-01
In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Higher-order ionospheric error at Arecibo, Millstone, and Jicamarca
NASA Astrophysics Data System (ADS)
Matteo, N. A.; Morton, Y. T.
2010-12-01
The ionosphere is a dominant source of Global Positioning System receiver range measurement error. Although dual-frequency receivers can eliminate the first-order ionospheric error, most second- and third-order errors remain in the range measurements. Higher-order ionospheric error is a function of both electron density distribution and the magnetic field vector along the GPS signal propagation path. This paper expands previous efforts by combining incoherent scatter radar (ISR) electron density measurements, the International Reference Ionosphere model, exponential decay extensions of electron densities, the International Geomagnetic Reference Field, and total electron content maps to compute higher-order error at ISRs in Arecibo, Puerto Rico; Jicamarca, Peru; and Millstone Hill, Massachusetts. Diurnal patterns, dependency on signal direction, seasonal variation, and geomagnetic activity dependency are analyzed. Higher-order error is largest at Arecibo with code phase maxima circa 7 cm for low-elevation southern signals. The maximum variation of the error over all angles of arrival is circa 8 cm.
The International Reference Ionosphere - Status 2013
NASA Astrophysics Data System (ADS)
Bilitza, Dieter
2015-04-01
This paper describes the latest version of the International Reference Ionosphere (IRI) model. IRI-2012 includes new models for the electron density and ion densities in the region below the F-peak, a storm-time model for the auroral E-region, an improved electron temperature model that includes variations with solar activity, and for the first time a description of auroral boundaries. In addition, the thermosphere model required for baseline neutral densities and temperatures was upgraded from MSIS-86 to the newer NRLMSIS-00 model and Corrected Geomagnetic coordinates (CGM) were included in IRI as an additional coordinate system for a better representation of auroral and polar latitudes. Ongoing IRI activities towards the inclusion of an improved model for the F2 peak height hmF2 are discussed as are efforts to develop a "Real-Time IRI". The paper is based on an IRI status report presented at the 2013 IRI Workshop in Olsztyn, Poland. The IRI homepage is at
NREL Pyrheliometer Comparisons: September 25-October 6, 2017 (NPC-2017)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reda, Ibrahim M.; Dooraghi, Michael R.; Andreas, Afshin M.
Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for themore » measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ASR) are subject to performance changes over time. Therefore, every five years the PMOD/WRC in Davos, Switzerland, hosts an International Pyrheliometer Comparison (IPC) for transferring the WRR to participating radiometers. NREL has represented the U.S. Department of Energy (DOE) in each IPC since 1980. As a result, NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). National Renewable Energy Laboratory (NREL) pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.« less
ERIC Educational Resources Information Center
Goel, Sanjay
2006-01-01
The growth of the Indian IT industry has been of great interest to the international IT community. Nearly one third of fresh Indian engineering graduates are currently joining the IT industry irrespective of their specialization. The success of the Indian IT industry, however, has not been yet been leveraged for developing India as a preferred…
User Guide to the PDS Dataset for the Cassini Composite Infrared Spectrometer (CIRS)
NASA Technical Reports Server (NTRS)
Nixon, Conor A.; Kaelberer, Monte S.; Gorius, Nicolas
2012-01-01
This User Guide to the Cassini Composite Infrared Spectrometer (CIRS) has been written with two communities in mind. First and foremost, scientists external to the Cassini Project who seek to use the CIRS data as archived in the Planetary Data System (PDS). In addition, it is intended to be a comprehensive reference guide for those internal to the CIRS team.
NASA Astrophysics Data System (ADS)
Kaufman, Richard
2017-12-01
A fairly recent paper resolves a large discrepancy in the internal energy utilized to fire a cannon as calculated by two inertial observers. Earth and its small reaction velocity must be considered in the system so that the change in kinetic energy is calculated correctly. This paper uses a car in a similar scenario, but considers the work done by forces acting over distances. An analysis of the system must include all energy interactions, including the work done on the car and especially the (negative) work done on Earth in a moving reference frame. This shows the importance of considering the force on Earth and the distance Earth travels. For calculation of work in inertial reference frames, the center of mass perspective is shown to be useful. We also consider the energy requirements to efficiently accelerate a mass among interacting masses.
Lorenzen, J; Habermann, C; Utler, C; Grzyska, U; Weber, C; Adam, G; Koops, A
2009-10-01
To evaluate the changes in academic quality indicators after implementation of a quality management system according to DIN ISO 9001:2000. After implementation and certification of a quality management system, the actual state based on quality indicators from the fields of student teaching, research, continuing education and the satisfaction of referring physician was determined. After implementation of an action plan for the individual areas, the temporal changes in the ratios were documented in the follow-up. The evaluation of teaching performance obtained by questionnaire among the students of the radiology course showed a steady increase in satisfaction (mean value 2003: 2.7; 2007: 3.9). In the field of research an increase in scientific output was achieved based on the number of an internal publication score (2002: 99 points; 2006: 509). Repeated opinion surveys among our referring physicians found improvements in indicators for the appointment of investigations, consulting service and waiting times for the investigation, while the waiting times for internal transport service did not improve. Exemplary measurements of the success of the advanced training of the staff demonstrated the need for continuing education for quality improvement. The evaluation of quality indicators showed over time a measurable positive impact on processes of a radiological University Hospital after implementation of a QM system according to DIN ISO 9001:2000. Georg Thieme Verlag KG Stuttgart-New York.
Internal Thermal Control System Hose Heat Transfer Fluid Thermal Expansion Evaluation Test Report
NASA Technical Reports Server (NTRS)
Wieland, P. O.; Hawk, H. D.
2001-01-01
During assembly of the International Space Station, the Internal Thermal Control Systems in adjacent modules are connected by jumper hoses referred to as integrated hose assemblies (IHAs). A test of an IHA has been performed at the Marshall Space Flight Center to determine whether the pressure in an IHA filled with heat transfer fluid would exceed the maximum design pressure when subjected to elevated temperatures (up to 60 C (140 F)) that may be experienced during storage or transportation. The results of the test show that the pressure in the IHA remains below 227 kPa (33 psia) (well below the 689 kPa (100 psia) maximum design pressure) even at a temperature of 71 C (160 F), with no indication of leakage or damage to the hose. Therefore, based on the results of this test, the IHA can safely be filled with coolant prior to launch. The test and results are documented in this Technical Memorandum.
Dubeau-Laramée, Geneviève; Rivière, Christophe; Jean, Isabelle; Mermut, Ozzy; Cohen, Luchino Y
2014-04-01
A fiber-optic based flow cytometry platform was designed to build a portable and robust instrument for space applications. At the core of the Microflow1 is a unique fiber-optic flow cell fitted to a fluidic system and fiber coupled to the source and detection channels. A Microflow1 engineering unit was first tested and benchmarked against a commercial flow cytometer as a reference in a standard laboratory environment. Testing in parabolic flight campaigns was performed to establish Microflow1's performance in weightlessness, before operating the new platform on the International Space Station. Microflow1 had comparable performances to commercial systems, and operated remarkably and robustly in weightlessness (microgravity). Microflow1 supported immunophenotyping as well as microbead-based multiplexed cytokine assays in the space environment and independently of gravity levels. Results presented here provide evidence that this fiber-optic cytometer technology is inherently compatible with the space environment with negligible compromise to analytical performance. © 2013 International Society for Advancement of Cytometry.
A dynamic gravimetric standard for trace water.
Brewer, P J; Goody, B A; Woods, P T; Milton, M J T
2011-10-01
A system for generating traceable reference standards of water vapor at trace levels between 5 and 2000 nmol/mol has been developed. It can provide different amount fractions of trace water vapor by using continuous accurate measurements of mass loss from a permeation device coupled with a dilution system based on an array of critical flow orifices. An estimated relative expanded uncertainty of ±2% has been achieved for most amount fractions generated. The system has been used in an international comparison and demonstrates excellent comparability with National Metrology Institutes maintaining standards of water vapor in this range using other methods.
Different approaches to overcome uncertainties of production systems
NASA Astrophysics Data System (ADS)
Azizi, Amir; Sorooshian, Shahryar
2015-05-01
This study presented a comprehensive review on the understanding of uncertainty and the current approaches that have been proposed to handle the uncertainties in the production systems. This paper classified proposed approaches into 11 groups. The paper studied 114 scholarly papers through various international journals. The paper added the latest findings to the body of knowledge to the current reservoir of understanding of the production uncertainties. Thus, the paper prepared the needs of researchers and practitioners for easy references in this area. This review also provided an excellent source to continue further studies on how to deal with the uncertainties of production system.
Schanz, Julie; Tüchler, Heinz; Solé, Francesc; Mallo, Mar; Luño, Elisa; Cervera, José; Granada, Isabel; Hildebrandt, Barbara; Slovak, Marilyn L.; Ohyashiki, Kazuma; Steidl, Christian; Fonatsch, Christa; Pfeilstöcker, Michael; Nösslinger, Thomas; Valent, Peter; Giagounidis, Aristoteles; Aul, Carlo; Lübbert, Michael; Stauder, Reinhard; Krieger, Otto; Garcia-Manero, Guillermo; Faderl, Stefan; Pierce, Sherry; Le Beau, Michelle M.; Bennett, John M.; Greenberg, Peter; Germing, Ulrich; Haase, Detlef
2012-01-01
Purpose The karyotype is a strong independent prognostic factor in myelodysplastic syndromes (MDS). Since the implementation of the International Prognostic Scoring System (IPSS) in 1997, knowledge concerning the prognostic impact of abnormalities has increased substantially. The present study proposes a new and comprehensive cytogenetic scoring system based on an international data collection of 2,902 patients. Patients and Methods Patients were included from the German-Austrian MDS Study Group (n = 1,193), the International MDS Risk Analysis Workshop (n = 816), the Spanish Hematological Cytogenetics Working Group (n = 849), and the International Working Group on MDS Cytogenetics (n = 44) databases. Patients with primary MDS and oligoblastic acute myeloid leukemia (AML) after MDS treated with supportive care only were evaluated for overall survival (OS) and AML evolution. Internal validation by bootstrap analysis and external validation in an independent patient cohort were performed to confirm the results. Results In total, 19 cytogenetic categories were defined, providing clear prognostic classification in 91% of all patients. The abnormalities were classified into five prognostic subgroups (P < .001): very good (median OS, 61 months; hazard ratio [HR], 0.5; n = 81); good (49 months; HR, 1.0 [reference category]; n = 1,809); intermediate (26 months; HR, 1.6; n = 529); poor (16 months; HR, 2.6; n = 148); and very poor (6 months; HR, 4.2; n = 187). The internal and external validations confirmed the results of the score. Conclusion In conclusion, these data should contribute to the ongoing efforts to update the IPSS by refining the cytogenetic risk categories. PMID:22331955
Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P
2014-01-01
The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger age and drop moderately as age increases. We have presented NHANES reference curves applicable to DXA whole-body scans acquired on GE Healthcare Lunar systems by age, sex and ethnicity. Users of GE Healthcare GE-Lunar DXA systems can now benefit from the large body composition reference data set collected in the NHANES 1999-2004 study. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Towards a model of temporal attention for on-line learning in a mobile robot
NASA Astrophysics Data System (ADS)
Marom, Yuval; Hayes, Gillian
2001-06-01
We present a simple attention system, capable of bottom-up signal detection adaptive to subjective internal needs. The system is used by a robotic agent, learning to perform phototaxis and obstacle avoidance by following a teacher agent around a simulated environment, and deciding when to form associations between perceived information and imitated actions. We refer to this kind of decision-making as on-line temporal attention. The main role of the attention system is perception of change; the system is regulated through feedback about cognitive effort. We show how different levels of effort affect both the ability to learn a task, and to execute it.
The twilight of the training analysis system.
Kernberg, Otto F
2014-04-01
This paper briefly reviews challenges to psychoanalysis at this time, including those derived from both external, societal origins and internal psychoanalytic problems. It focuses attention on serious conflicts around psychoanalytic education, and refers to the training analysis system as a central problem determining fundamental constraints on present-day psychoanalytic education. These constraints are examined in some detail, and the general advantages and disadvantages of the training analysis system are outlined. The effects of all these dynamics on the administrative organization of the American Psychoanalytic Association are explored, and a proposal for a fundamental reorganization of our educational system to resolve the correspondent problems is outlined.
Radio-Optical Reference Frame Link Using the U.S. Naval Observatory Astrograph and Deep CCD Imaging
NASA Astrophysics Data System (ADS)
Zacharias, N.; Zacharias, M. I.
2014-05-01
Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reduced following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.
Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L
2008-11-01
Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.
Radio-optical reference frame link using the U.S. Naval observatory astrograph and deep CCD imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zacharias, N.; Zacharias, M. I., E-mail: nz@usno.navy.mil
2014-05-01
Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reducedmore » following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.« less
A First Look at the Upcoming SISO Space Reference FOM
NASA Technical Reports Server (NTRS)
Mueller, Bjorn; Crues, Edwin Z.; Dexter, Dan; Garro, Alfredo; Skuratovskiy, Anton; Vankov, Alexander
2016-01-01
Spaceflight is difficult, dangerous and expensive; human spaceflight even more so. In order to mitigate some of the danger and expense, professionals in the space domain have relied, and continue to rely, on computer simulation. Simulation is used at every level including concept, design, analysis, construction, testing, training and ultimately flight. As space systems have grown more complex, new simulation technologies have been developed, adopted and applied. Distributed simulation is one those technologies. Distributed simulation provides a base technology for segmenting these complex space systems into smaller, and usually simpler, component systems or subsystems. This segmentation also supports the separation of responsibilities between participating organizations. This segmentation is particularly useful for complex space systems like the International Space Station (ISS), which is composed of many elements from many nations along with visiting vehicles from many nations. This is likely to be the case for future human space exploration activities. Over the years, a number of distributed simulations have been built within the space domain. While many use the High Level Architecture (HLA) to provide the infrastructure for interoperability, HLA without a Federation Object Model (FOM) is insufficient by itself to insure interoperability. As a result, the Simulation Interoperability Standards Organization (SISO) is developing a Space Reference FOM. The Space Reference FOM Product Development Group is composed of members from several countries. They contribute experiences from projects within NASA, ESA and other organizations and represent government, academia and industry. The initial version of the Space Reference FOM is focusing on time and space and will provide the following: (i) a flexible positioning system using reference frames for arbitrary bodies in space, (ii) a naming conventions for well-known reference frames, (iii) definitions of common time scales, (iv) federation agreements for common types of time management with focus on time stepped simulation, and (v) support for physical entities, such as space vehicles and astronauts. The Space Reference FOM is expected to make collaboration politically, contractually and technically easier. It is also expected to make collaboration easier to manage and extend.
Mobile camera-space manipulation
NASA Technical Reports Server (NTRS)
Seelinger, Michael J. (Inventor); Yoder, John-David S. (Inventor); Skaar, Steven B. (Inventor)
2001-01-01
The invention is a method of using computer vision to control systems consisting of a combination of holonomic and nonholonomic degrees of freedom such as a wheeled rover equipped with a robotic arm, a forklift, and earth-moving equipment such as a backhoe or a front-loader. Using vision sensors mounted on the mobile system and the manipulator, the system establishes a relationship between the internal joint configuration of the holonomic degrees of freedom of the manipulator and the appearance of features on the manipulator in the reference frames of the vision sensors. Then, the system, perhaps with the assistance of an operator, identifies the locations of the target object in the reference frames of the vision sensors. Using this target information, along with the relationship described above, the system determines a suitable trajectory for the nonholonomic degrees of freedom of the base to follow towards the target object. The system also determines a suitable pose or series of poses for the holonomic degrees of freedom of the manipulator. With additional visual samples, the system automatically updates the trajectory and final pose of the manipulator so as to allow for greater precision in the overall final position of the system.
ERIC Educational Resources Information Center
Energy Information Administration (DOE), Washington, DC.
This booklet is a compilation of energy data providing a reference to a much broader range of domestic and international energy data. It is designed especially as a quick reference to major facts about energy. The data includes information for 1976 through 1988, except for international energy data, which is for 1977 through 1987. Graphs, charts,…
Henry, Suzanne Bakken; Warren, Judith J.; Lange, Linda; Button, Patricia
1998-01-01
Building on the work of previous authors, the Computer-based Patient Record Institute (CPRI) Work Group on Codes and Structures has described features of a classification scheme for implementation within a computer-based patient record. The authors of the current study reviewed the evaluation literature related to six major nursing vocabularies (the North American Nursing Diagnosis Association Taxonomy 1, the Nursing Interventions Classification, the Nursing Outcomes Classification, the Home Health Care Classification, the Omaha System, and the International Classification for Nursing Practice) to determine the extent to which the vocabularies include the CPRI features. None of the vocabularies met all criteria. The Omaha System, Home Health Care Classification, and International Classification for Nursing Practice each included five features. Criteria not fully met by any systems were clear and non-redundant representation of concepts, administrative cross-references, syntax and grammar, synonyms, uncertainty, context-free identifiers, and language independence. PMID:9670127
Validation of psychoanalytic theories: towards a conceptualization of references.
Zachrisson, Anders; Zachrisson, Henrik Daae
2005-10-01
The authors discuss criteria for the validation of psychoanalytic theories and develop a heuristic and normative model of the references needed for this. Their core question in this paper is: can psychoanalytic theories be validated exclusively from within psychoanalytic theory (internal validation), or are references to sources of knowledge other than psychoanalysis also necessary (external validation)? They discuss aspects of the classic truth criteria correspondence and coherence, both from the point of view of contemporary psychoanalysis and of contemporary philosophy of science. The authors present arguments for both external and internal validation. Internal validation has to deal with the problems of subjectivity of observations and circularity of reasoning, external validation with the problem of relevance. They recommend a critical attitude towards psychoanalytic theories, which, by carefully scrutinizing weak points and invalidating observations in the theories, reduces the risk of wishful thinking. The authors conclude by sketching a heuristic model of validation. This model combines correspondence and coherence with internal and external validation into a four-leaf model for references for the process of validating psychoanalytic theories.
International Geomagnetic Reference Field: the third generation.
Peddie, N.W.
1982-01-01
In August 1981 the International Association of Geomagnetism and Aeronomy revised the International Geomagnetic Reference Field (IGRF). It is the second revision since the inception of the IGRF in 1968. The revision extends the earlier series of IGRF models from 1980 to 1985, introduces a new series of definitive models for 1965-1976, and defines a provisional reference field for 1975- 1980. The revision consists of: 1) a model of the main geomagnetic field at 1980.0, not continuous with the earlier series of IGRF models together with a forecast model of the secular variation of the main field during 1980-1985; 2) definitive models of the main field at 1965.0, 1970.0, and 1975.0, with linear interpolation of the model coefficients specified for intervening dates; and 3) a provisional reference field for 1975-1980, defined as the linear interpolation of the 1975 and 1980 main-field models.-from Author
Working Performance Analysis of Rolling Bearings Used in Mining Electric Excavator Crowd Reducer
NASA Astrophysics Data System (ADS)
Zhang, Y. H.; Hou, G.; Chen, G.; Liang, J. F.; Zheng, Y. M.
2017-12-01
Refer to the statistical load data of digging process, on the basis of simulation analysis of crowd reducer system dynamics, the working performance simulation analysis of rolling bearings used in crowd reducer of large mining electric excavator is completed. The contents of simulation analysis include analysis of internal load distribution, rolling elements contact stresses and rolling bearing fatigue life. The internal load characteristics of rolling elements in cylindrical roller bearings are obtained. The results of this study identified that all rolling bearings satisfy the requirements of contact strength and fatigue life. The rationality of bearings selection and arrangement is also verified.
Report of the panel on international programs
NASA Technical Reports Server (NTRS)
Anderson, Allen Joel; Fuchs, Karl W.; Ganeka, Yasuhiro; Gaur, Vinod; Green, Andrew A.; Siegfried, W.; Lambert, Anthony; Rais, Jacub; Reighber, Christopher; Seeger, Herman
1991-01-01
The panel recommends that NASA participate and take an active role in the continuous monitoring of existing regional networks, the realization of high resolution geopotential and topographic missions, the establishment of interconnection of the reference frames as defined by different space techniques, the development and implementation of automation for all ground-to-space observing systems, calibration and validation experiments for measuring techniques and data, the establishment of international space-based networks for real-time transmission of high density space data in standardized formats, tracking and support for non-NASA missions, and the extension of state-of-the art observing and analysis techniques to developing nations.
Current Status of Herbal Drug Standards in the Indian Pharmacopoeia.
Prakash, Jai; Srivastava, Sushma; Ray, R S; Singh, Neha; Rajpali, Roshni; Singh, Gyanendra Nath
2017-12-01
The benefits of herbal drugs were well understood way back. They have been used for the promotion of health and medical purposes - in disease conditions. It is a conventional belief that herbal drugs have no side effects, are cheaper and locally available. Among Indian systems of medicines, herbs/herbal formulations are used to a larger extent. The quality control of the marketed herbs/herbal formulations is important for acquiring optimum therapeutic benefit as well as for expanding global outreach. Therefore, herbal drug standards are important. Reference standards, the Indian Pharmacopoeia Reference Substances especially the botanical reference substances and the phytochemical reference substances are required for comparison of quality of herbal drugs. The Indian Pharmacopoeia Commission has initiated the process of providing Indian Pharmacopoeia Reference Substances to the stakeholders. Therefore, this article provides an overview of the history and the status of herbal drug standards in the current and forthcoming issues of Indian Pharmacopoeia. In Indian Pharmacopeia, efforts have been made for the harmonization of standards with international counterparts wherever possible. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Dynamical Reference Frame: Current Relevance and Future Prospects
NASA Technical Reports Server (NTRS)
Standish, E. M., Jr
2000-01-01
Planetary and lunar ephemerides are no longer used for the determination of inertial space. Instead, the new fundamental reference frame, the International Celestial Reference Frame (ICRF), is inherently less susceptible to extraneous, non-inertial rotations than a dynamical reference frame determined by the ephemerides would be. Consequently, the ephemerides are now adjusted onto the ICRF, and they are fit to two modern, accurate observational data types: ranging (radar, lunar laser, spacecraft) and Very Long Baseline Interferometry (VLBI) (of spacecraft near planets). The uncertainties remaining in the inner planet ephemerides are on the order of 1 kilometer, both in relative positions between the bodies and in the orientation of the inner system as a whole. The predictive capabilities of the inner planet ephemerides are limited by the uncertainties in the masses of many asteroids. For this reason, future improvements to the ephemerides must await determinations of many asteroid masses. Until then, it will be necessary to constantly update the ephemerides with a continuous supply of observational data.
NASA Technical Reports Server (NTRS)
Helms, W. Jason; Pohlkamp, Kara M.
2011-01-01
The Space Shuttle does not dock at an exact 90 degrees to the International Space Station (ISS) x-body axis. This offset from 90 degrees, along with error sources within their respective attitude knowledge, causes the two vehicles to never completely agree on their attitude, even though they operate as a single, mated stack while docked. The docking offset can be measured in flight when both vehicles have good attitude reference and is a critical component in calculations to transfer attitude reference from one vehicle to another. This paper will describe how the docking offset and attitude reference errors between both vehicles are measured and how this information would be used to recover Shuttle attitude reference from ISS in the event of multiple failures. During STS-117, ISS on-board Guidance, Navigation and Control (GNC) computers began having problems and after several continuous restarts, the systems failed. The failure took the ability for ISS to maintain attitude knowledge. This paper will also demonstrate how with knowledge of the docking offset, the contingency procedure to recover Shuttle attitude reference from ISS was reversed in order to provide ISS an attitude reference from Shuttle. Finally, this paper will show how knowledge of the docking offset can be used to speed up attitude control handovers from Shuttle to ISS momentum management. By taking into account the docking offset, Shuttle can be commanded to hold a more precise attitude which better agrees with the ISS commanded attitude such that start up transients with the ISS momentum management controllers are reduced. By reducing start-up transients, attitude control can be transferred from Shuttle to ISS without the use of ISS thrusters saving precious on-board propellant, crew time and minimizing loads placed upon the mated stack.
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Sarif; Kurauchi, Shinya; Yoshii, Toshio
2017-06-01
In the conventional travel behavior models such as logit and probit, decision makers are assumed to conduct the absolute evaluations on the attributes of the choice alternatives. On the other hand, many researchers in cognitive psychology and marketing science have been suggesting that the perceptions of attributes are characterized by the benchmark called “reference points” and the relative evaluations based on them are often employed in various choice situations. Therefore, this study developed a travel behavior model based on the mental accounting theory in which the internal reference points are explicitly considered. A questionnaire survey about the shopping trip to the CBD in Matsuyama city was conducted, and then the roles of reference points in travel mode choice contexts were investigated. The result showed that the goodness-of-fit of the developed model was higher than that of the conventional model, indicating that the internal reference points might play the major roles in the choice of travel mode. Also shown was that the respondents seem to utilize various reference points: some tend to adopt the lowest fuel price they have experienced, others employ fare price they feel in perceptions of the travel cost.
The International Human Epigenome Consortium Data Portal.
Bujold, David; Morais, David Anderson de Lima; Gauthier, Carol; Côté, Catherine; Caron, Maxime; Kwan, Tony; Chen, Kuang Chung; Laperle, Jonathan; Markovits, Alexei Nordell; Pastinen, Tomi; Caron, Bryan; Veilleux, Alain; Jacques, Pierre-Étienne; Bourque, Guillaume
2016-11-23
The International Human Epigenome Consortium (IHEC) coordinates the production of reference epigenome maps through the characterization of the regulome, methylome, and transcriptome from a wide range of tissues and cell types. To define conventions ensuring the compatibility of datasets and establish an infrastructure enabling data integration, analysis, and sharing, we developed the IHEC Data Portal (http://epigenomesportal.ca/ihec). The portal provides access to >7,000 reference epigenomic datasets, generated from >600 tissues, which have been contributed by seven international consortia: ENCODE, NIH Roadmap, CEEHRC, Blueprint, DEEP, AMED-CREST, and KNIH. The portal enhances the utility of these reference maps by facilitating the discovery, visualization, analysis, download, and sharing of epigenomics data. The IHEC Data Portal is the official source to navigate through IHEC datasets and represents a strategy for unifying the distributed data produced by international research consortia. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Automated extraction of knowledge for model-based diagnostics
NASA Technical Reports Server (NTRS)
Gonzalez, Avelino J.; Myler, Harley R.; Towhidnejad, Massood; Mckenzie, Frederic D.; Kladke, Robin R.
1990-01-01
The concept of accessing computer aided design (CAD) design databases and extracting a process model automatically is investigated as a possible source for the generation of knowledge bases for model-based reasoning systems. The resulting system, referred to as automated knowledge generation (AKG), uses an object-oriented programming structure and constraint techniques as well as internal database of component descriptions to generate a frame-based structure that describes the model. The procedure has been designed to be general enough to be easily coupled to CAD systems that feature a database capable of providing label and connectivity data from the drawn system. The AKG system is capable of defining knowledge bases in formats required by various model-based reasoning tools.
NASA Astrophysics Data System (ADS)
Esparza, Javier
In many areas of computer science entities can “reproduce”, “replicate”, or “create new instances”. Paramount examples are threads in multithreaded programs, processes in operating systems, and computer viruses, but many others exist: procedure calls create new incarnations of the callees, web crawlers discover new pages to be explored (and so “create” new tasks), divide-and-conquer procedures split a problem into subproblems, and leaves of tree-based data structures become internal nodes with children. For lack of a better name, I use the generic term systems with process creation to refer to all these entities.
Skylab Rescue Space Vehicle OAT No. 1 Plugs in Test
NASA Technical Reports Server (NTRS)
Jevitt, S. J.
1973-01-01
A test is described which demonstrates the compatibility of the Skylab Rescue Space Vehicle systems, the ground support equipment, and off-site support facilities by proceeding through a simulated launch countdown, liftoff, and flight. The functions of propellant loading, umbilical ejection, holddown arm release, service arm retraction, liftoff, and inflight separation are simulated. An external power source supplies transfer power to internal, and instrument unit commands are simulated by the digital command system. The test outline is presented along with a list of references, intercommunications information, radio frequency matrix, and interface control chart.
1991-09-06
R.L. Duncombe, O.G. Franz, capabilities of the Hubble Space L.W. Fredrick, T. Gerard, Telescope fine guidance sensors P.D. Hemenway, B. McArthur, J...frame: Counterproposal to the Circular Letter no. 4 of Kovalevsky - I - .) 10. H. Eichhorn The organization of space : frames, systems and 97 standards...Heifets of REGATTA-ASTRO space astrometry program 48. W. Jin, T. Xu, Influence of systematic differences of FK4 on 280 P. Lu, and D. Liao determining
NASA Astrophysics Data System (ADS)
Kim, Han Sung; Yeom, Yeon Soo; Tat Nguyen, Thang; Choi, Chansoo; Han, Min Cheol; Lee, Jai Ki; Kim, Chan Hyeong; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Qiu, Rui; Eckerman, Keith; Chung, Beom Sun
2017-03-01
It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.
Method and apparatus for detecting internal structures of bulk objects using acoustic imaging
Deason, Vance A.; Telschow, Kenneth L.
2002-01-01
Apparatus for producing an acoustic image of an object according to the present invention may comprise an excitation source for vibrating the object to produce at least one acoustic wave therein. The acoustic wave results in the formation of at least one surface displacement on the surface of the object. A light source produces an optical object wavefront and an optical reference wavefront and directs the optical object wavefront toward the surface of the object to produce a modulated optical object wavefront. A modulator operatively associated with the optical reference wavefront modulates the optical reference wavefront in synchronization with the acoustic wave to produce a modulated optical reference wavefront. A sensing medium positioned to receive the modulated optical object wavefront and the modulated optical reference wavefront combines the modulated optical object and reference wavefronts to produce an image related to the surface displacement on the surface of the object. A detector detects the image related to the surface displacement produced by the sensing medium. A processing system operatively associated with the detector constructs an acoustic image of interior features of the object based on the phase and amplitude of the surface displacement on the surface of the object.
Korean anatomical reference data for adults for use in radiological protection
NASA Astrophysics Data System (ADS)
Choi, Chansoo; Yeom, Yeon Soo; Nguyen, Thang Tat; Lee, Hanjin; Han, Haegin; Shin, Bangho; Zhang, Xujia; Kim, Chan Hyeong; Chung, Beom Sun
2018-01-01
For radiological protection from exposure to ionizing radiation, in which a population-averaged dose evaluation is used, establishing a system of reference anatomical and physiological data for a specific population of interest is important. Some studies were done in the past to establish Korean reference data; however, the data provided the mass values only for a limited number of organs/tissues. In addition, the standing height and total body mass are based on 20-year-old data. In the present study, a new set of Korean reference anatomical values was established for use in the radiological protection of Korean workers and members of the public. The established Korean reference data provide the masses of 58 organs/tissues, including those needed to calculate the effective dose, which were derived by collecting and analyzing various scientific reports in the literature and data. In addition, the data provide not only standing height and total body mass, but also 131 additional anthropometric parameters; these values were derived from the most recent Korean national survey project, 7 th Size Korea. The characteristics of the data were also compared with several other population data, including the Asian and the International Commission on Radiological Protection (ICRP) reference data.
Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel
2016-05-01
-The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.
Automated vocabulary discovery for geo-parsing online epidemic intelligence.
Keller, Mikaela; Freifeld, Clark C; Brownstein, John S
2009-11-24
Automated surveillance of the Internet provides a timely and sensitive method for alerting on global emerging infectious disease threats. HealthMap is part of a new generation of online systems designed to monitor and visualize, on a real-time basis, disease outbreak alerts as reported by online news media and public health sources. HealthMap is of specific interest for national and international public health organizations and international travelers. A particular task that makes such a surveillance useful is the automated discovery of the geographic references contained in the retrieved outbreak alerts. This task is sometimes referred to as "geo-parsing". A typical approach to geo-parsing would demand an expensive training corpus of alerts manually tagged by a human. Given that human readers perform this kind of task by using both their lexical and contextual knowledge, we developed an approach which relies on a relatively small expert-built gazetteer, thus limiting the need of human input, but focuses on learning the context in which geographic references appear. We show in a set of experiments, that this approach exhibits a substantial capacity to discover geographic locations outside of its initial lexicon. The results of this analysis provide a framework for future automated global surveillance efforts that reduce manual input and improve timeliness of reporting.
GCOS reference upper air network (GRUAN): Steps towards assuring future climate records
NASA Astrophysics Data System (ADS)
Thorne, P. W.; Vömel, H.; Bodeker, G.; Sommer, M.; Apituley, A.; Berger, F.; Bojinski, S.; Braathen, G.; Calpini, B.; Demoz, B.; Diamond, H. J.; Dykema, J.; Fassò, A.; Fujiwara, M.; Gardiner, T.; Hurst, D.; Leblanc, T.; Madonna, F.; Merlone, A.; Mikalsen, A.; Miller, C. D.; Reale, T.; Rannat, K.; Richter, C.; Seidel, D. J.; Shiotani, M.; Sisterson, D.; Tan, D. G. H.; Vose, R. S.; Voyles, J.; Wang, J.; Whiteman, D. N.; Williams, S.
2013-09-01
The observational climate record is a cornerstone of our scientific understanding of climate changes and their potential causes. Existing observing networks have been designed largely in support of operational weather forecasting and continue to be run in this mode. Coverage and timeliness are often higher priorities than absolute traceability and accuracy. Changes in instrumentation used in the observing system, as well as in operating procedures, are frequent, rarely adequately documented and their impacts poorly quantified. For monitoring changes in upper-air climate, which is achieved through in-situ soundings and more recently satellites and ground-based remote sensing, the net result has been trend uncertainties as large as, or larger than, the expected emergent signals of climate change. This is more than simply academic with the tropospheric temperature trends issue having been the subject of intense debate, two international assessment reports and several US congressional hearings. For more than a decade the international climate science community has been calling for the instigation of a network of reference quality measurements to reduce uncertainty in our climate monitoring capabilities. This paper provides a brief history of GRUAN developments to date and outlines future plans. Such reference networks can only be achieved and maintained with strong continuing input from the global metrological community.
Romano, Paolo; Manniello, Assunta; Aresu, Ottavia; Armento, Massimiliano; Cesaro, Michela; Parodi, Barbara
2009-01-01
The Cell Line Data Base (CLDB) is a well-known reference information source on human and animal cell lines including information on more than 6000 cell lines. Main biological features are coded according to controlled vocabularies derived from international lists and taxonomies. HyperCLDB (http://bioinformatics.istge.it/hypercldb/) is a hypertext version of CLDB that improves data accessibility by also allowing information retrieval through web spiders. Access to HyperCLDB is provided through indexes of biological characteristics and navigation in the hypertext is granted by many internal links. HyperCLDB also includes links to external resources. Recently, an interest was raised for a reference nomenclature for cell lines and CLDB was seen as an authoritative system. Furthermore, to overcome the cell line misidentification problem, molecular authentication methods, such as fingerprinting, single-locus short tandem repeat (STR) profile and single nucleotide polymorphisms validation, were proposed. Since this data is distributed, a reference portal on authentication of human cell lines is needed. We present here the architecture and contents of CLDB, its recent enhancements and perspectives. We also present a new related database, the Cell Line Integrated Molecular Authentication (CLIMA) database (http://bioinformatics.istge.it/clima/), that allows to link authentication data to actual cell lines. PMID:18927105
Romano, Paolo; Manniello, Assunta; Aresu, Ottavia; Armento, Massimiliano; Cesaro, Michela; Parodi, Barbara
2009-01-01
The Cell Line Data Base (CLDB) is a well-known reference information source on human and animal cell lines including information on more than 6000 cell lines. Main biological features are coded according to controlled vocabularies derived from international lists and taxonomies. HyperCLDB (http://bioinformatics.istge.it/hypercldb/) is a hypertext version of CLDB that improves data accessibility by also allowing information retrieval through web spiders. Access to HyperCLDB is provided through indexes of biological characteristics and navigation in the hypertext is granted by many internal links. HyperCLDB also includes links to external resources. Recently, an interest was raised for a reference nomenclature for cell lines and CLDB was seen as an authoritative system. Furthermore, to overcome the cell line misidentification problem, molecular authentication methods, such as fingerprinting, single-locus short tandem repeat (STR) profile and single nucleotide polymorphisms validation, were proposed. Since this data is distributed, a reference portal on authentication of human cell lines is needed. We present here the architecture and contents of CLDB, its recent enhancements and perspectives. We also present a new related database, the Cell Line Integrated Molecular Authentication (CLIMA) database (http://bioinformatics.istge.it/clima/), that allows to link authentication data to actual cell lines.
NASA Astrophysics Data System (ADS)
Sun, Zhiyong; Hao, Lina; Song, Bo; Yang, Ruiguo; Cao, Ruimin; Cheng, Yu
2016-10-01
Micro/nano positioning technologies have been attractive for decades for their various applications in both industrial and scientific fields. The actuators employed in these technologies are typically smart material actuators, which possess inherent hysteresis that may cause systems behave unexpectedly. Periodic reference tracking capability is fundamental for apparatuses such as scanning probe microscope, which employs smart material actuators to generate periodic scanning motion. However, traditional controller such as PID method cannot guarantee accurate fast periodic scanning motion. To tackle this problem and to conduct practical implementation in digital devices, this paper proposes a novel control method named discrete extended unparallel Prandtl-Ishlinskii model based internal model (d-EUPI-IM) control approach. To tackle modeling uncertainties, the robust d-EUPI-IM control approach is investigated, and the associated sufficient stabilizing conditions are derived. The advantages of the proposed controller are: it is designed and represented in discrete form, thus practical for digital devices implementation; the extended unparallel Prandtl-Ishlinskii model can precisely represent forward/inverse complex hysteretic characteristics, thus can reduce modeling uncertainties and benefits controllers design; in addition, the internal model principle based control module can be utilized as a natural oscillator for tackling periodic references tracking problem. The proposed controller was verified through comparative experiments on a piezoelectric actuator platform, and convincing results have been achieved.
Nonuniform Deployment of Autonomous Agents in Harbor-Like Environments
2014-11-12
ith agent than to all other agents. Interested readers are referred to [55] for the comprehensive study on Voronoi partitioning and its applications...robots: An rfid approach, PhD dissertation, School of Electrical Engi- neering and Computer Science, University of Ottawa (October 2012). [55] A. Okabe, B...Gueaieb, A stochastic approach of mobile robot navigation using customized rfid sys- tems, International Conference on Signals, Circuits and Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reda, Ibrahim M; Dooraghi, Michael R; Sengupta, Manajit
Presenting results of five comparisons between ACPs and IRISs and the difference between the longwave irradiance measured by the ACPs and IRISs versus the average irradiance measured by the WISG. The process of CIMO recommendation to establish the world reference for measuring the atmospheric longwave irradiance with traceability to the International System of Units (SI) is also presented.
Geoscience Australia Continuous Global Positioning System (CGPS) Station Field Campaign Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruddick, R.; Twilley, B.
2016-03-01
This station formed part of the Australian Regional GPS Network (ARGN) and South Pacific Regional GPS Network (SPRGN), which is a network of continuous GPS stations operating within Australia and its Territories (including Antarctica) and the Pacific. These networks support a number of different science applications including maintenance of the Geospatial Reference Frame, both national and international, continental and tectonic plate motions, sea level rise, and global warming.
Application of Wear Debris Analysis to Aircraft Hydraulic Systems.
1982-05-10
C. Wescott, "Predicting and Determining Failures by Means of Ferrography ", paper given at Ninth Annual FAA International Aviation Maintenance...morphological characteristics (reference (c)). In this particular effort the morphologi- cal studies were performed by means of analytical ferrography ...peak of 191,000 at 225 hours. As time progressed, the index again began to fall and returned to Ref: (c) "Wear Particle Atlas " Naval Air Engineering
Human-Robot Interaction: A Survey
2007-01-01
breaks with the monolithic sense- plan -act loop of a centralized system, and instead uses distributed sense-response loops to generate appropriate...one of the first modern robots, cour- tesy of SRI International, Menlo Park, CA [279]; Kismet — an anthropomorphic robot with exaggerated emotion...linguis- tics. A common autonomy approach is sometimes referred to as the sense- plan -act model of decision-making [196]. This model has been a target
Exciter For X-Band Transmitter And Receiver
NASA Technical Reports Server (NTRS)
Johns, Carl E.
1989-01-01
Report describes developmental X-band exciter for X-band uplink subsystem of Deep Space Network. X-band transmitter-exciting signal expected to have fractional frequency stability of 5.2 X 10 to negative 15th power during 1,000-second integration period. Generates coherent test signals for S- and X-band Block III translator of Deep Space Network, Doppler-reference signal for associated Doppler-extractor system, first-local-oscillator signal for associated receiver, and reference signal for associated ranging subsystem. Tests of prototype exciter show controlling and monitoring and internal phase-correcting loops perform according to applicable design criteria. Measurements of stability of frequency and of single-sideband noise spectral density of transmitter-exciting signal made subsequently.
NASA Astrophysics Data System (ADS)
Podestá, R.; Pacheco, A. M.; Alvis Rojas, H.; Quinteros, J.; Podestá, F.; Albornoz, E.; Navarro, A.; Luna, M.
2018-01-01
This work shows the strategy followed for the co-location of the Satellite Laser Ranging (SLR) ILRS 7406 telescope and the antenna of the permanent Global Positioning System (GPS) station, located at the Félix Aguilar Astronomical Observatory (OAFA) in San Juan, Argentina. The accomplishment of the co-location consisted in the design, construction, measurement, adjustment and compensation of a geodesic net between the stations SLR and GPS, securing support points solidly built in the soil. The co-location allows the coordinates of the station to be obtained by combining the data of both SLR and GPS techniques, achieving a greater degree of accuracy than individually. The International Earth Rotation and Reference Systems Service (IERS) considers the co-located stations as the most valuable and important points for the maintenance of terrestrial reference systems and their connection with the celestial ones. The 3 mm precision required by the IERS has been successfully achieved.
Global precipitation measurement (GPM)
NASA Astrophysics Data System (ADS)
Neeck, Steven P.; Flaming, Gilbert M.; Adams, W. James; Smith, Eric A.
2001-12-01
The National Aeronautics and Space Administration (NASA) is studying options for future space-based missions for the EOS Follow-on Era (post 2003), building upon the measurements made by Pre-EOS and EOS First Series Missions. One mission under consideration is the Global Precipitation Measurement (GPM), a cooperative venture of NASA, Japan, and other international partners. GPM will capitalize on the experience of the highly successful Tropical Rainfall Measurement Mission (TRMM). Its goal is to extend the measurement of rainfall to high latitudes with high temporal frequency, providing a global data set every three hours. A reference concept has been developed consisting of an improved TRMM-like primary satellite with precipitation radar and microwave radiometer to make detailed and accurate estimates of the precipitation structure and a constellation of small satellites flying compact microwave radiometers to provide the required temporal sampling of highly variable precipitation systems. Considering that DMSP spacecraft equipped with SSMIS microwave radiometers, successor NPOESS spacecraft equipped with CMIS microwave radiometers, and other relevant international systems are expected to be in operation during the timeframe of the reference concept, the total number of small satellites required to complete the constellation will be reduced. A nominal plan is to begin implementation in FY'03 with launches in 2007. NASA is presently engaged in advanced mission studies and advanced instrument technology development related to the mission.
ISS-CREAM Thermal and Fluid System Design and Analysis
NASA Technical Reports Server (NTRS)
Thorpe, Rosemary S.
2015-01-01
Thermal and Fluids Analysis Workshop (TFAWS), Silver Spring MD NCTS 21070-15. The ISS-CREAM (Cosmic Ray Energetics And Mass for the International Space Station) payload is being developed by an international team and will provide significant cosmic ray characterization over a long time frame. Cold fluid provided by the ISS Exposed Facility (EF) is the primary means of cooling for 5 science instruments and over 7 electronics boxes. Thermal fluid integrated design and analysis was performed for CREAM using a Thermal Desktop model. This presentation will provide some specific design and modeling examples from the fluid cooling system, complex SCD (Silicon Charge Detector) and calorimeter hardware, and integrated payload and ISS level modeling. Features of Thermal Desktop such as CAD simplification, meshing of complex hardware, External References (Xrefs), and FloCAD modeling will be discussed.
IGS 1996 Analysis Center Workshop
NASA Technical Reports Server (NTRS)
Neilan, R. E. (Editor); VanScoy, P. A. (Editor); Zumberge, J. F. (Editor)
1996-01-01
Components of the IGS[International GPS (Global Positioning System) Service for geodynamics], have operated a GPS tracking system for several years. The network now contains more than 100 stations and has produced a combined GPS ephemeris that has become the standard for geodesists and geophysicists worldwide. IGS data and products are freely available to all thanks to the cooperation and participation of all the IGS members. The IGS has initiated development of several new products, and technical issues permitting greater accuracy of IGS products have been identified. The IGS convened a workshop on March 1996 in Silver Spring, Maryland, USA, to coordinate these developments and to examine technical problems and solutions. The following topics were addressed: orbit/clock combination; Earth orientation; antenna calibration; SINEX and densification of the International Terrestrial Reference Frame (ITRF) using the GPS; receiver standards and performance; and atmospheric topics.
The Smartphone-Based Offline Indoor Location Competition at IPIN 2016: Analysis and Future Work
Torres-Sospedra, Joaquín; Jiménez, Antonio R.; Knauth, Stefan; Moreira, Adriano; Beer, Yair; Fetzer, Toni; Ta, Viet-Cuong; Montoliu, Raul; Seco, Fernando; Mendoza-Silva, Germán M.; Belmonte, Oscar; Koukofikis, Athanasios; Nicolau, Maria João; Costa, António; Meneses, Filipe; Ebner, Frank; Deinzer, Frank; Vaufreydaz, Dominique; Dao, Trung-Kien; Castelli, Eric
2017-01-01
This paper presents the analysis and discussion of the off-site localization competition track, which took place during the Seventh International Conference on Indoor Positioning and Indoor Navigation (IPIN 2016). Five international teams proposed different strategies for smartphone-based indoor positioning using the same reference data. The competitors were provided with several smartphone-collected signal datasets, some of which were used for training (known trajectories), and others for evaluating (unknown trajectories). The competition permits a coherent evaluation method of the competitors’ estimations, where inside information to fine-tune their systems is not offered, and thus provides, in our opinion, a good starting point to introduce a fair comparison between the smartphone-based systems found in the literature. The methodology, experience, feedback from competitors and future working lines are described. PMID:28287447
ERIC Educational Resources Information Center
Chen, Ssu-Kuang; Hwang, Fang-Ming; Yeh, Yu-Chen; Lin, Sunny S. J.
2012-01-01
Background: Marsh's internal/external (I/E) frame of reference model depicts the relationship between achievement and self-concept in specific academic domains. Few efforts have been made to examine concurrent relationships among cognitive ability, achievement, and academic self-concept (ASC) within an I/E model framework. Aim: To simultaneously…
Intrinsic Bioprobes, Inc. (Tempe, AZ)
Nelson, Randall W [Phoenix, AZ; Williams, Peter [Phoenix, AZ; Krone, Jennifer Reeve [Granbury, TX
2008-07-15
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Reference C16-C18 Internal Olefin Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS OIL AND GAS EXTRACTION POINT SOURCE CATEGORY...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Reference C16-C18 Internal Olefin Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS OIL AND GAS EXTRACTION POINT SOURCE CATEGORY...
Mass spectrometric immunoassay
Nelson, Randall W; Williams, Peter; Krone, Jennifer Reeve
2007-12-04
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
Mass spectrometric immunoassay
Nelson, Randall W; Williams, Peter; Krone, Jennifer Reeve
2013-07-16
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
Mass spectrometric immunoassay
Nelson, Randall W.; Williams, Peter; Krone, Jennifer Reeve
2005-12-13
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
Meija, Juris; Chartrand, Michelle M G
2018-01-01
Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.
Citations of Brazilian physical therapy journals in national publications
Teixeira, Renan K. C.; Yamaki, Vitor N.; Botelho, Nara M.; Teixeira, Renato C.
2014-01-01
Background Quotations in Brazilian journals are mainly obtained from national articles (articles from Brazilian journals); thus, it is essential to determine how frequently these articles reference Brazilian journals. Objective This study sought to verify how frequently national papers are cited in the references of three Brazilian physical therapy journals. Method All references for articles published in Fisioterapia em Movimento, Fisioterapia e Pesquisa and Revista Brasileira de Fisioterapia between 2010 and 2012 were evaluated. In particular, the numbers of national articles and international articles (articles from international journals) cited in these references were determined. Results A total of 13,009 references cited by 456 articles were analyzed, and 2,924 (22.47%) of the cited works were national articles. There were no significant differences among the three examined years. A total of 36 (7.89%) articles did not cite national articles, whereas 65 (13.25%) articles cited more national articles than international articles. Conclusion On average, 22.47% of the works cited by the evaluated articles were national articles. No significant differences were detected among the three analyzed years. PMID:24675917
Establishment of metrological traceability in porosity measurements by x-ray computed tomography
NASA Astrophysics Data System (ADS)
Hermanek, Petr; Carmignato, Simone
2017-09-01
Internal porosity is an inherent phenomenon to many manufacturing processes, such as casting, additive manufacturing, and others. Since these defects cannot be completely avoided by improving production processes, it is important to have a reliable method to detect and evaluate them accurately. The accurate evaluation becomes even more important concerning current industrial trends to minimize size and weight of products on one side, and enhance their complexity and performance on the other. X-ray computed tomography (CT) has emerged as a promising instrument for holistic porosity measurements offering several advantages over equivalent methods already established in the detection of internal defects. The main shortcomings of the conventional techniques pertain to too general information about total porosity content (e.g. Archimedes method) or the destructive way of testing (e.g. microscopy of cross-sections). On the contrary, CT is a nondestructive technique providing complete information about size, shape and distribution of internal porosity. However, due to the lack of international standards and the fact that it is relatively a new measurement technique, CT as a measurement technology has not yet reached maturity. This study proposes a procedure for the establishment of measurement traceability in porosity measurements by CT including the necessary evaluation of measurement uncertainty. The traceability transfer is carried out through a novel reference standard calibrated by optical and tactile coordinate measuring systems. The measurement uncertainty is calculated following international standards and guidelines. In addition, the accuracy of porosity measurements by CT with the associated measurement uncertainty is evaluated using the reference standard.
Guillén, J; Beresford, N A; Baeza, A; Izquierdo, M; Wood, M D; Salas, A; Muñoz-Serrano, A; Corrales-Vázquez, J M; Muñoz-Muñoz, J G
2018-06-01
A system for the radiological protection of the environment (or wildlife) based on Reference Animals and Plants (RAPs) has been suggested by the International Commission on Radiological Protection (ICRP). To assess whole-body activity concentrations for RAPs and the resultant internal dose rates, transfer parameters are required. However, transfer values specifically for the taxonomic families defined for the RAPs are often sparse and furthermore can be extremely site dependent. There is also a considerable geographical bias within available transfer data, with few data for Mediterranean ecosystems. In the present work, stable element concentrations (I, Li, Be, B, Na, Mg, Al, P, S, K. Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Mo, Ag, Cd, Cs, Ba, Tl, Pb and U) in terrestrial RAPs, and the corresponding whole-body concentration ratios, CR wo , were determined in two different Mediterranean ecosystems: a Pinewood and a Dehesa (grassland with disperse tree cover). The RAPs considered in the Pinewood ecosystem were Pine Tree and Wild Grass; whereas in the Dehesa ecosystem those considered were Deer, Rat, Earthworm, Bee, Frog, Duck and Wild Grass. The CR wo values estimated from these data are compared to those reported in international compilations and databases. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Synchronization trigger control system for flow visualization
NASA Technical Reports Server (NTRS)
Chun, K. S.
1987-01-01
The use of cinematography or holographic interferometry for dynamic flow visualization in an internal combustion engine requires a control device that globally synchronizes camera and light source timing at a predefined shaft encoder angle. The device is capable of 0.35 deg resolution for rotational speeds of up to 73 240 rpm. This was achieved by implementing the shaft encoder signal addressed look-up table (LUT) and appropriate latches. The developed digital signal processing technique achieves 25 nsec of high speed triggering angle detection by using direct parallel bit comparison of the shaft encoder digital code with a simulated angle reference code, instead of using angle value comparison which involves more complicated computation steps. In order to establish synchronization to an AC reference signal whose magnitude is variant with the rotating speed, a dynamic peak followup synchronization technique has been devised. This method scrutinizes the reference signal and provides the right timing within 40 nsec. Two application examples are described.
Phase change references for in-flight recalibration of orbital thermometry
NASA Astrophysics Data System (ADS)
Topham, T. S.; Latvakoski, H.; Watson, M.
2013-09-01
Several critical questions need to be answered to determine the potential utility of phase change materials as long-term orbital references: How accurate and repeatable will phase change reference implementations be after incorporating necessary design trade-offs to accommodate launch and the space environment? How can the temperature of phase transitions be transferred to something useful for calibration such as a black body. How, if at all, will the microgravity environment affect the phase transitions? To help answer some of these questions, three experiments will be conducted on the International Space Station (ISS). The experiments will test melts and freezes of three different phase change materials in various containment apparatus. This paper addresses the current status of the ISS experiments, as well as results from ground testing of several concepts for space application of PCM recalibration systems in the CORSAIR (Calibration Observations of Radiance Spectra in the far Infrared) black body.
Sittig, Dean F.; Singh, Hardeep
2011-01-01
Conceptual models have been developed to address challenges inherent in studying health information technology (HIT). This manuscript introduces an 8-dimensional model specifically designed to address the socio-technical challenges involved in design, development, implementation, use, and evaluation of HIT within complex adaptive healthcare systems. The 8 dimensions are not independent, sequential, or hierarchical, but rather are interdependent and interrelated concepts similar to compositions of other complex adaptive systems. Hardware and software computing infrastructure refers to equipment and software used to power, support, and operate clinical applications and devices. Clinical content refers to textual or numeric data and images that constitute the “language” of clinical applications. The human computer interface includes all aspects of the computer that users can see, touch, or hear as they interact with it. People refers to everyone who interacts in some way with the system, from developer to end-user, including potential patient-users. Workflow and communication are the processes or steps involved in assuring that patient care tasks are carried out effectively. Two additional dimensions of the model are internal organizational features (e.g., policies, procedures, and culture) and external rules and regulations, both of which may facilitate or constrain many aspects of the preceding dimensions. The final dimension is measurement and monitoring, which refers to the process of measuring and evaluating both intended and unintended consequences of HIT implementation and use. We illustrate how our model has been successfully applied in real-world complex adaptive settings to understand and improve HIT applications at various stages of development and implementation. PMID:20959322
Sittig, Dean F; Singh, Hardeep
2010-10-01
Conceptual models have been developed to address challenges inherent in studying health information technology (HIT). This manuscript introduces an eight-dimensional model specifically designed to address the sociotechnical challenges involved in design, development, implementation, use and evaluation of HIT within complex adaptive healthcare systems. The eight dimensions are not independent, sequential or hierarchical, but rather are interdependent and inter-related concepts similar to compositions of other complex adaptive systems. Hardware and software computing infrastructure refers to equipment and software used to power, support and operate clinical applications and devices. Clinical content refers to textual or numeric data and images that constitute the 'language' of clinical applications. The human--computer interface includes all aspects of the computer that users can see, touch or hear as they interact with it. People refers to everyone who interacts in some way with the system, from developer to end user, including potential patient-users. Workflow and communication are the processes or steps involved in ensuring that patient care tasks are carried out effectively. Two additional dimensions of the model are internal organisational features (eg, policies, procedures and culture) and external rules and regulations, both of which may facilitate or constrain many aspects of the preceding dimensions. The final dimension is measurement and monitoring, which refers to the process of measuring and evaluating both intended and unintended consequences of HIT implementation and use. We illustrate how our model has been successfully applied in real-world complex adaptive settings to understand and improve HIT applications at various stages of development and implementation.
Modeling and closed-loop control of hypnosis by means of bispectral index (BIS) with isoflurane.
Gentilini, A; Rossoni-Gerosa, M; Frei, C W; Wymann, R; Morari, M; Zbinden, A M; Schnider, T W
2001-08-01
A model-based closed-loop control system is presented to regulate hypnosis with the volatile anesthetic isoflurane. Hypnosis is assessed by means of the bispectral index (BIS), a processed parameter derived from the electroencephalogram. Isoflurane is administered through a closed-circuit respiratory system. The model for control was identified on a population of 20 healthy volunteers. It consists of three parts: a model for the respiratory system, a pharmacokinetic model and a pharmacodynamic model to predict BIS at the effect compartment. A cascaded internal model controller is employed. The master controller compares the actual BIS and the reference value set by the anesthesiologist and provides expired isoflurane concentration references to the slave controller. The slave controller maneuvers the fresh gas anesthetic concentration entering the respiratory system. The controller is designed to adapt to different respiratory conditions. Anti-windup measures protect against performance degradation in the event of saturation of the input signal. Fault detection schemes in the controller cope with BIS and expired concentration measurement artifacts. The results of clinical studies on humans are presented.
ERIC Educational Resources Information Center
Zimmermann, Friederike; Möller, Jens; Köller, Olaf
2018-01-01
The internal/external frame of reference model (I/E model) posits that individuals' achievement-related self-concepts are formed through social comparisons (e.g., self vs. peers) within academic domains and dimensional comparisons (e.g., math vs. verbal) between distinct domains. A large body of research has supported the theorized pattern of…
ERIC Educational Resources Information Center
Goetz, Thomas; Frenzel, Anne C.; Hall, Nathan C.; Pekrun, Reinhard
2008-01-01
The present study focused on students' academic enjoyment as predicted by achievement in multiple academic domains. Assumptions were based on Marsh's internal/external (I/E) frame of reference model and Pekrun's control-value theory of achievement emotions, and were tested in a sample of 1380 German students from grades 5 to 10. Students' academic…
ERIC Educational Resources Information Center
Clarke, Marie; Killeavy, Maureen
2012-01-01
Background: Teacher education is an area of concern both in the policy and practice domains in both international and national contexts. Internationally, there are a wide range teacher education programmes and there is also considerable diversity with reference to policy approaches that operationalise such provision. Purpose: This paper focuses on…
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resolution A.393(X), adopted on 14 November 1977, Recommendation on International Performance and Test...), Guidelines on the Enhanced Programme of Inspections During Surveys of Bulk Carriers and Oil Tankers, Annex B... reference approved for § 157.445. (c) Oil Companies International Marine Forum (OCIMF) 27 Queen Anne's Gate...
The Reciprocal Internal/External Frame of Reference Model Using Grades and Test Scores
ERIC Educational Resources Information Center
Möller, Jens; Zimmermann, Friederike; Köller, Olaf
2014-01-01
Background: The reciprocal I/E model (RI/EM) combines the internal/external frame of reference model (I/EM) with the reciprocal effects model (REM). The RI/EM extends the I/EM longitudinally and the REM across domains. The model predicts that, within domains, mathematics and verbal achievement (VACH) and academic self-concept have positive effects…
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.
Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie
2018-01-01
The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Kessler, Rodger
2012-01-01
Most primary care patients with mental health issues are identified or treated in primary care rather than the specialty mental health system. Primary care physicians report that their patients do not have access to needed mental health care. When referrals are made to the specialty behavioral or mental health care system, rates of patients who initiate treatment are low. Collaborative care models, with mental health clinicians as part of the primary care medical staff, have been suggested as an alternative. The aim of this study is to examine rates of treatment startup in 2 collaborative care settings: a rural family medicine office and a suburban internal medicine office. In both practices referrals for mental health services are made within the practice. Referral data were drawn from 2 convenience samples of patients referred by primary care physicians for collaborative mental health treatment at Fletcher Allen Health Care in Vermont. The first sample consisted of 93 consecutively scheduled referrals in a family medicine office (sample A) between January 2006 and December 2007. The second sample consisted of 215 consecutive scheduled referrals at an internal medicine office (sample B) between January 2009 and December 2009. Referral data identified age, sex, and presenting mental health/medical problem. In sample A, 95.5% of those patients scheduling appointments began behavioral health treatment; in sample B this percentage was 82%. In sample B, 69% of all patients initially referred for mental health care both scheduled and initiated treatment. When referred to a mental health clinician who provides on-site access as part of a primary care mental health collaborative care model, a high percentage of patients referred scheduled care. Furthermore, of those who scheduled care, a high percentage of patients attend the scheduled appointment. Findings persist despite differences in practice type, populations, locations, and time frames of data collection. That the findings persist across the different offices suggests that this model of care may contain elements that improve the longstanding problem of poor treatment initiation rates when primary care physicians refer patients for outpatient behavioral health services.
Explanatory Supplement to the Astronomical Almanac (3rd Edition)
NASA Astrophysics Data System (ADS)
Urban, Sean E.; Seidelmann, P. K.
2014-01-01
Publications and software from the the Astronomical Applications Department of the US Naval Observatory (USNO) are used throughout the world, not only in the Department of Defense for safe navigation, but by many people including other navigators, astronomers, aerospace engineers, and geodesists. Products such as The Nautical Almanac, The Astronomical Almanac, and the Multiyear Interactive Computer Almanac (MICA) are regarded as international standards. To maintain credibility, it is imperative that the methodologies employed and the data used are well documented. "The Explanatory Supplement to the Astronomical Almanac" (hereafter, "The ES") is a major source of such documentation. It is a comprehensive reference book on positional astronomy, covering the theories and algorithms used to produce The Astronomical Almanac, an annual publication produced jointly by the Nautical Almanac Office of USNO and Her Majesty's Nautical Almanac Office (HMNAO). The first edition of The ES appeared in 1961, and the second followed in 1992. Several major changes have taken place in fundamental astronomy since the second edition was published. Advances in radio observations allowed the celestial reference frame to be tied to extragalactic radio sources, thus the International Celestial Reference System replaced the FK5 system. The success of ESA's Hipparcos satellite dramatically altered observational astrometry. Improvements in Earth orientation observations lead to new precession and nutation theories. Additionally, a new positional paradigm, no longer tied to the ecliptic and equinox, was accepted. Largely because of these changes, staff at USNO and HMNAO decided the time was right for the next edition of The ES. The third edition is now available; it is a complete revision of the 1992 book. Along with subjects covered in the previous two editions, the book also contains descriptions of the major advancements in positional astronomy over the last 20 years, some of which are described above. Extensive references to online information are given. This paper will discuss this latest edition of the Explanatory Supplement.
Amateur Radio on the International Space Station: The First Operational Payload on the ISS
NASA Technical Reports Server (NTRS)
Bauer, Frank H.; McFadin, Lou; Steiner, Mark D.; Conley, Carolynn L.
2002-01-01
As astronauts and cosmonauts have adapted to life on the International Space Station (ISS), they have found amateur radio and its connection to life on Earth to be a important on-board companion and a substantial psychological boost. Since its first use in November 2000, the first five expedition crews have utilized the amateur radio station in the Functional Cargo Block (also referred to as the FGB or Zarya module) to talk to thousands of students in schools, to their families on Earth, and to amateur radio operators around the world. This paper will discuss the development, qualification, installation and operation of the amateur radio system. It will also discuss some of the challenges that the amateur radio international team of volunteers overcame to bring its first phase of equipment on ISS to fruition.
[Asymmetry in international relations, industrial property rights and anti-HIV medication].
Costa-Couto, Maria Helena; Nascimento, Alvaro César
2008-01-01
This paper analyzes the asymmetry in the international relations as refers to the recognition of industrial property rights in the pharmaceutical industry. It focuses on the impact of such relations upon the access to ARV medication, an issue of worldwide interest due to its connection with the development of the nations. Clashing interests and the position taken by some countries in their patent laws point to a scenario less favorable for the access of peripheral countries to anti-HIV/AIDS medication. On the other hand, it seems that the success of the Brazilian STD/AIDS program in negotiating ARV prices will open new possibilities. The solution may be the internal strengthening of the National States and the active role played by the Agencies of the United Nations System in defense of the collective human interests.
SuperJet International case study: a business network start-up in the aeronautics industry
NASA Astrophysics Data System (ADS)
Corallo, Angelo; de Maggio, Marco; Storelli, Davide
This chapter presents the SuperJet International case study, a start-up in the aeronautics industry characterized by a process-oriented approach and a complex and as yet evolving network of partnerships and collaborations. The chapter aims to describe the key points of the start-up process, highlighting common factors and differences compared to the TEKNE Methodology of Change, with particular reference to the second and third phase, namely, the design and deployment of new techno-organizational systems. The SuperJet International startup is presented as a case study where strategic and organizational aspects have been jointly conceived from a network-driven perspective. The chapter compares some of the guidelines of the TEKNE Methodology of Change with experiences and actual practices deriving from interviews with key players in SJI's start-up process.
The CIPM list of recommended frequency standard values: guidelines and procedures
NASA Astrophysics Data System (ADS)
Riehle, Fritz; Gill, Patrick; Arias, Felicitas; Robertsson, Lennart
2018-04-01
A list of standard reference frequency values (LoF) of quantum transitions from the microwave to the optical regime has been recommended by the International Committee for Weights and Measures (Comité international des poids et mesures, CIPM) for use in basic research, technology, and for the metrology of time, frequency and length. The CIPM LoF contains entries that are recommended as secondary representations of the second in the International System of Units, and entries that can be used to serve as realizations of the definition of the metre. The historical perspective that led to the CIPM LoF is outlined. Procedures have been developed for updating existing, and validating new, entries into the CIPM LoF. The CIPM LoF might serve as an entry for a future redefinition of the second by an optical transition.
NASA Astrophysics Data System (ADS)
Krzan, Grzegorz; Stępniak, Katarzyna
2017-09-01
In high-accuracy positioning using GNSS, the most common solution is still relative positioning using double-difference observations of dual-frequency measurements. An increasingly popular alternative to relative positioning are undifferenced approaches, which are designed to make full use of modern satellite systems and signals. Positions referenced to global International Terrestrial Reference Frame (ITRF2008) obtained from Precise Point Positioning (PPP) or Undifferenced (UD) network solutions have to be transformed to national (regional) reference frame, which introduces additional bases related to the transformation process. In this paper, satellite observations from two test networks using different observation time series were processed. The first test concerns the positioning accuracy from processing one year of dual-frequency GPS observations from 14 EUREF Permanent Network (EPN) stations using NAPEOS 3.3.1 software. The results were transformed into a national reference frame (PL-ETRF2000) and compared to positions from an EPN cumulative solution, which was adopted as the true coordinates. Daily observations were processed using PPP and UD multi-station solutions to determine the final accuracy resulting from satellite positioning, the transformation to national coordinate systems and Eurasian intraplate plate velocities. The second numerical test involved similar processing strategies of post-processing carried out using different observation time series (30 min., 1 hour, 2 hours, daily) and different classes of GNSS receivers. The centimeter accuracy of results presented in the national coordinate system satisfies the requirements of many surveying and engineering applications.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-03-01
A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-01-01
Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390
Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A
2003-01-20
Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan
[Information flow between medical and social sciences].
Schubert, András; Somogyi, Anikó
2014-12-28
In order to reveal impacts of natural and social sciences on each other, the authors examined connections between fields of medical and social sciences using a search for references and citations of scientific publication. 1. The largest affinity between the medical and social sciences was found between neurosciences and psychology, but there was a significant affinity between clinical sciences and general social sciences, as well. 2. The example of General & Internal Medicine papers in the topics of "diabetes" suggests that in the period 2001-2010 the share of references to social sciences was significantly increased. In the meantime, social science papers in the same topics contained references to Clinical Medicine papers in a constantly high percentage. 3. In the sample under study, the age distribution of social science papers in the references did not differ significantly from that of the other sources. 4. Share of references to social science papers was found to be extremely high among Hungarian General & Internal Medicine papers in the topics of "diabetes". This finding still requires clarification, nevertheless, since e.g. it was not supported by an institutional comparison including the largest Hungarian medical research university. 5. The intensity of the reference/citation mediated information flows between the Hungarian Medical Journal, Orvosi Hetilap and social sciences appears to be in accordance with the current international trends.
Geographical BSE risk assessment and its impact on disease detection and dissemination.
Salman, Mo; Silano, Vittorio; Heim, Dagmar; Kreysa, Joachim
2012-08-01
Bovine Spongiform Encephalopathy (BSE) rapidly evolved into an issue of major public concern particularly when, in 1996, evidence was provided that this disease had crossed the species barrier and infected humans in the UK with what has become known as "variant Creutzfeldt Jakob Disease" (vCJD). The aim of this paper is to describe the European Geographical BSE risk assessment (GBR) that was successfully used for assessing the qualitative likelihood that BSE could be present in a country where it was not yet officially recognized. It also discusses how this can lead to risk-based and therefore preventive management of BSE at national and international levels. The basic assumption of the GBR method is that the BSE agent is initially introduced into a country's domestic cattle production system through the importation of contaminated feedstuffs or live cattle. This is referred to as an "external challenge". The ability of the system to cope with such a challenge is, in turn, referred to as its "stability": a stable system will not allow the BSE agent to propagate and amplify following its introduction, while an unstable system will. The BSE-status of a country assessed by this system was used by the European Commission as the basis for trade legislation rules for cattle and their products. The GBR was an invaluable tool in evaluating the potential global spread of BSE as it demonstrated how a disease could be transferred through international trade. This was shown to be a critical factor to address in reducing the spread and amplification of BSE throughout the world. Furthermore, GBR resulted in the implementation of additional measures and management activities both to improve surveillance and to prevent transmission within the cattle population. Copyright © 2012 Elsevier B.V. All rights reserved.
Stucki, Gerold; Bickenbach, Jerome; Melvin, John
2017-09-01
A complete understanding of the experience of health requires information relevant not merely to the health indicators of mortality and morbidity but also to functioning-that is, information about what it means to live in a health state, "the lived experience of health." Not only is functioning information relevant to healthcare and the overall objectives of person-centered healthcare but to the successful operation of all components of health systems.In light of population aging and major epidemiological trends, the health strategy of rehabilitation, whose aim has always been to optimize functioning and minimize disability, will become a key health strategy. The increasing prominence of the rehabilitative strategy within the health system drives the argument for the integration of functioning information as an essential component in national health information systems.Rehabilitation professionals and researchers have long recognized in WHO's International Classification of Functioning, Disability and Health the best prospect for an internationally recognized, sufficiently complete and powerful information reference for the documentation of functioning information. This paper opens the discussion of the promise of integrating the ICF as an essential component in national health systems to secure access to functioning information for rehabilitation, across health systems and countries.
A Study for Mars Manned Exploration
NASA Technical Reports Server (NTRS)
Dorney, Daniel J.; Scimemi, Sam
2012-01-01
Over the last five decades there have been numerous studies devoted to developing, launching and conducting a manned mission to Mars by both Russian and U.S. organizations. These studies have proposed various crew sizes, mission length, propulsion systems, habitation modules, and scientific goals. As a first step towards establishing an international partnership approach to a Mars mission, the most recent Russian concepts are explored and then compared to NASA's latest Mars reference mission.
Possible Scenarios for Mars Manned Exploration
NASA Technical Reports Server (NTRS)
Dorney, Daniel J.; Schumacher, Daniel M.
2012-01-01
Over the last five decades there have been numerous studies devoted to developing, launching and conducting a manned mission to Mars by both Russian and U.S. organizations. These studies have proposed various crew sizes, mission length, propulsion systems, habitation modules, and scientific goals. As a first step towards establishing an international partnership approach to a Mars mission, the most recent Russian concepts are explored and then compared to NASA's current Mars reference mission.
ASSIST internals reference manual
NASA Technical Reports Server (NTRS)
Johnson, Sally C.; Boerschlein, David P.
1994-01-01
The Abstract Semi-Markov Specification Interface to the SURE Tool (ASSIST) program was developed at NASA LaRC in order to analyze the reliability of virtually any fault-tolerant system. A user manual was developed to detail its use. Certain technical specifics are of no concern to the end user, yet are of importance to those who must maintain and/or verify the correctness of the tool. This document takes a detailed look into these technical issues.
Communications/Navigation Outage Forecasting System (C/NOFS)
2010-02-21
al., 2002]. They are also lower than values predicted by the International Reference Iono- sphere ( IRI ) model [Gulyaeva and Titheridge, 2006] run for...based on the IRI model or other observations. At present no mechanism has been proposed which accounts for the basic formation of BPDs or their...funding by the DMSP program office. We thank J. Retterer for the IRI model results. This research was supported by Air Force Office of Scientific Research
SSME environment database development
NASA Technical Reports Server (NTRS)
Reardon, John
1987-01-01
The internal environment of the Space Shuttle Main Engine (SSME) is being determined from hot firings of the prototype engines and from model tests using either air or water as the test fluid. The objectives are to develop a database system to facilitate management and analysis of test measurements and results, to enter available data into the the database, and to analyze available data to establish conventions and procedures to provide consistency in data normalization and configuration geometry references.
Crosstalk: The Journal of Defense Software Engineering. Volume 22, Number 3
2009-04-01
international standard for information security management systems like ISO /IEC 27001 :2005 [1] existed. Since that time, the organization has developed control...of ISO /IEC 27001 and the desire to make decisions based on business value and risk has prompted Ford’s IT Security and Controls organi- zation to begin...their conventional application security operation.u References 1. ISO /IEC 27001 :2005. “Information Technology – Security Techniques – Information
International GPS Service 2001 - 2002 Technical Reports
NASA Technical Reports Server (NTRS)
Gowey, Ken (Editor); Neilan, Ruth (Editor); Moore, Angelyn (Editor)
2004-01-01
Applications of the Global Positioning System (GPS) to Earth Science are numerous. The International GPS Service (IGS), a federation of government agencies and universities, plays an increasingly critical role in support of GPS-related research and engineering activities. Contributions from the IGS Governing Board and Central Bureau, analysis and data centers, station operators, and others constitute the 2001 / 2002 Technical Reports. Hard copies of each volume can be obtained by contacting the IGS Central Bureau at the Jet Propulsion Laboratory. This report is published in black and white. To view graphs or plots that use color to represent data trends or information, please refer to the online PDF version at http://igscb.jpl.nasa.gov/overview/pubs.html.
Project Management for International Development.
ERIC Educational Resources Information Center
Axelrod, Valija M.; Magisos, Joel H.
A project developed a content model for international project management training. It also compiled a bibliography of project management references, identified specific project management training needs based upon a survey of international sponsors and contractor personnel, and documented the training needs of international project managers. Data…
The role of microbiological testing in systems for assuring the safety of beef.
Brown, M H; Gill, C O; Hollingsworth, J; Nickelson, R; Seward, S; Sheridan, J J; Stevenson, T; Sumner, J L; Theno, D M; Usborne, W R; Zink, D
2000-12-05
The use of microbiological testing in systems for assuring the safety of beef was considered at a meeting arranged by the International Livestock Educational Foundation as part of the International Livestock Congress, TX, USA, during February, 2000. The 11 invited participants from industry and government research organizations concurred in concluding that microbiological testing is necessary for the implementation and maintenance of effective Hazard Analysis Critical Control Point (HACCP) systems, which are the only means of assuring the microbiological safety of beef; that microbiological testing for HACCP purposes must involve the enumeration of indicator organisms rather than the detection of pathogens; that the efficacy of process control should be assessed against performance criteria and food safety objectives that refer to the numbers of indicator organisms in product; that sampling procedures should allow indicator organisms to be enumerated at very low numbers; and that food safety objectives and microbiological criteria are better related to variables, rather than attributes sampling plans.
Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V
2014-01-01
The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.
Interoperable web applications for sharing data and products of the International DORIS Service
NASA Astrophysics Data System (ADS)
Soudarin, L.; Ferrage, P.
2017-12-01
The International DORIS Service (IDS) was created in 2003 under the umbrella of the International Association of Geodesy (IAG) to foster scientific research related to the French satellite tracking system DORIS and to deliver scientific products, mostly related to the International Earth rotation and Reference systems Service (IERS). Since its start, the organization has continuously evolved, leading to additional and improved operational products from an expanded set of DORIS Analysis Centers. In addition, IDS has developed services for sharing data and products with the users. Metadata and interoperable web applications are proposed to explore, visualize and download the key products such as the position time series of the geodetic points materialized at the ground tracking stations. The Global Geodetic Observing System (GGOS) encourages the IAG Services to develop such interoperable facilities on their website. The objective for GGOS is to set up an interoperable portal through which the data and products produced by the IAG Services can be served to the user community. We present the web applications proposed by IDS to visualize time series of geodetic observables or to get information about the tracking ground stations and the tracked satellites. We discuss the future plans for IDS to meet the recommendations of GGOS. The presentation also addresses the needs for the IAG Services to adopt common metadata thesaurus to describe data and products, and interoperability standards to share them.
NASA Astrophysics Data System (ADS)
Beldavs, Vid; Atvars, Aigars; Ubelis, Arnolds; Salmins, Kalvis; Crisafulli, Jim; Dunlop, David; Foing, Bernard
2015-04-01
In 1957 at the dawn of the space age the United Nations launched the International Geophysical Year which had a profound impact on collaboration among scientists around the globe. Its legacy includes several major scientific organizations as well as the beginnings of collaboration among nations that see themselves as competitors on Earth. The Soviet Union and the United States made many attempts at collaboration in space while building weapons systems to destroy each other. Space technologies have become the infrastructure for the ubiquitous smart phone with global telecommunications, navigation, weather forecasting, environmental monitoring, and hundreds of other applications. In 2015, the International Year of Light, several conferences will be held exploring the idea of an International Lunar Decade1 An informal group, the International Lunar Decade Working Group (ILDWG) has been formed to plan the launch of the International Lunar Decade in 2017, the 60th Anniversary of the International Geophysical Year. This report will cover the progress of the ILDWG covering conferences planned, international organizations involved and key publications. The activities of the ILDWG can be followed at http://2014giantleap.aerospacehawaii.info/. References [1] V. Beldavs, 2014 'The International Lunar Decade', The Space Review, http://www.thespacereview.com/article/2431/1
Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Jia; Sun, Guohua; Li, Hongmei
2012-10-15
Certified reference materials (CRMs) of water content are widely used in the calibration and validation of Karl Fischer coulometry and volumetry. In this study, the water content of the water saturated 1-octanol (WSO) CRM was certified by Karl Fischer coulometry, volumetry and quantitative nuclear magnetic resonance (Q NMR). The water content recovery by coulometry was 99.76% with a diaphragm-less electrode and Coulomat AG anolyte. The relative bias between the coulometry and volumetry results was 0.06%. In Q NMR, the water content of WSO is traceable to the International System (SI) of units through the purity of internal standard. The relative bias of water content in WSO between Q NMR and volumetry was 0.50%. The consistency of results for these three independent methods improves the accuracy of the certification of the RM. The certified water content of the WSO CRM was 4.76% with an expanded uncertainty of 0.09%. Copyright © 2012 Elsevier Ltd. All rights reserved.
Giulianotti, Richard; Robertson, Roland
2012-06-01
This paper provides a sociological model of the key transnational political and economic forces that are shaping the 'global football field'. The model draws upon, and significantly extends, the theory of the 'global field' developed previously by Robertson. The model features four quadrants, each of which contains a dominant operating principle, an 'elemental reference point', and an 'elemental theme'. The quadrants contain, first, neo-liberalism, associated with the individual and elite football clubs; second, neo-mercantilism, associated with nation-states and national football systems; third, international relations, associated with international governing bodies; and fourth, global civil society, associated with diverse institutions that pursue human development and/or social justice. We examine some of the interactions and tensions between the major institutional and ideological forces across the four quadrants. We conclude by examining how the weakest quadrant, featuring global civil society, may gain greater prominence within football. In broad terms, we argue that our four-fold model may be utilized to map and to examine other substantive research fields with reference to globalization. © London School of Economics and Political Science 2012.
Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants
NASA Technical Reports Server (NTRS)
Juhasz, A. J.
1983-01-01
An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as liquid pumping and internal compression. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.
Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants
NASA Technical Reports Server (NTRS)
Juhasz, A. J.
1983-01-01
An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as 'liquid pumping and internal compression'. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.
Tipping elements in the Earth's climate system.
Lenton, Timothy M; Held, Hermann; Kriegler, Elmar; Hall, Jim W; Lucht, Wolfgang; Rahmstorf, Stefan; Schellnhuber, Hans Joachim
2008-02-12
The term "tipping point" commonly refers to a critical threshold at which a tiny perturbation can qualitatively alter the state or development of a system. Here we introduce the term "tipping element" to describe large-scale components of the Earth system that may pass a tipping point. We critically evaluate potential policy-relevant tipping elements in the climate system under anthropogenic forcing, drawing on the pertinent literature and a recent international workshop to compile a short list, and we assess where their tipping points lie. An expert elicitation is used to help rank their sensitivity to global warming and the uncertainty about the underlying physical mechanisms. Then we explain how, in principle, early warning systems could be established to detect the proximity of some tipping points.
Goldblatt, Peter
2015-12-25
Ooms et al sets out some good general principles for a global social support system to improve fairer global competitiveness as a result of redistribution. This commentary sets out to summarize some of the conditions that would need to be satisfied for it to level up gradients in inequality through such a social support system, using the National Basketball Association (NBA) example as a point of reference. From this, the minimal conditions are described that would be required for the support system, proposed in the article by Ooms et al, to succeed. © 2016 by Kerman University of Medical Sciences.
NASA Astrophysics Data System (ADS)
Kodet, J.; Schreiber, K. U.; Eckl, J.; Plötz, C.; Mähler, S.; Schüler, T.; Klügel, T.; Riepl, S.
2018-01-01
The quality of the links between the different space geodetic techniques (VLBI, SLR, GNSS and DORIS) is still one of the major limiting factors for the realization of a unique global terrestrial reference frame that is accurate enough to allow the monitoring of the Earth system, i.e., of processes like sea level change, postglacial rebound and silent earthquakes. According to the specifications of the global geodetic observing system of the International Association of Geodesy, such a reference frame should be accurate to 1 mm over decades, with rates of change stable at the level of 0.1 mm/year. The deficiencies arise from inaccurate or incomplete local ties at many fundamental sites as well as from systematic instrumental biases in the individual space geodetic techniques. Frequently repeated surveys, the continuous monitoring of antenna heights and the geometrical mount stability (Lösler et al. in J Geod 90:467-486, 2016. https://doi.org/10.1007/s00190-016-0887-8) have not provided evidence for insufficient antenna stability. Therefore, we have investigated variations in the respective system delays caused by electronic circuits, which is not adequately captured by the calibration process, either because of subtle differences in the circuitry between geodetic measurement and calibration, high temporal variability or because of lacking resolving bandwidth. The measured system delay variations in the electric chain of both VLBI- and SLR systems reach the order of 100 ps, which is equivalent to 3 cm of path length. Most of this variability is usually removed by the calibrations but by far not all. This paper focuses on the development of new technologies and procedures for co-located geodetic instrumentation in order to identify and remove systematic measurement biases within and between the individual measurement techniques. A closed-loop optical time and frequency distribution system and a common inter-technique reference target provide the possibility to remove variable system delays. The main motivation for the newly established central reference target, locked to the station clock, is the combination of all space geodetic instruments at a single reference point at the observatory. On top of that it provides the unique capability to perform a closure measurement based on the observation of time.
ERIC Educational Resources Information Center
Marsh, Herbert W.; Abduljabbar, Adel Salah; Parker, Philip D.; Morin, Alexandre J. S.; Abdelfattah, Faisal; Nagengast, Benjamin; Möller, Jens; Abu-Hilal, Maher M.
2015-01-01
The internal/external frame of reference (I/E) model and dimensional comparison theory posit paradoxical relations between achievement (ACH) and self-concept (SC) in mathematics (M) and verbal (V) domains; ACH in each domain positively affects SC in the matching domain (e.g., MACH to MSC) but negatively in the nonmatching domain (e.g., MACH to…
Verbal and Math Self-Concepts: An Extension of the Internal/External Frame of Reference Model.
ERIC Educational Resources Information Center
Marsh, Herbert W.; Byrne, Barbara M.
The internal/external (I/E) frame of reference model describes relations among Verbal self-concept (VSC), Math self-concept (MSC), and corresponding achievement scores (VACH, MACH). In support of the model Marsh (1986) found that: (1) VSC and MSC were nearly uncorrelated; (2) the effect of VACH on VSC, and of MACH on MSC, were positive; but (3)…
Status and Future Developments of SIRGAS
NASA Astrophysics Data System (ADS)
Fortes, L.; Lauría, E.; Brunini, C.; Amaya, W.; Sanchez, L.; Drewes, H.
2007-05-01
This paper presents the status and future developments of the SIRGAS (Geocentric Reference System for the Americas) project. Since its creation, in 1993, SIRGAS has coordinated two continental GPS campaigns in 1995 an 2000, responsible for the establishment of a very accurate 3D reference frame in the region. First focusing on South America, the project has expanded its scope to Latin America since 2001. Currently the maintenance of the SIRGAS reference frame is carried out through more than 80 continuous operating GNSS (Global Navigation Satellite System) stations available in the region, whose data is officially processed by the International GNSS Service (IGS) Regional Network Associate Analysis Centre for SIRGAS (IGS RNACC-SIR), functioning at the DGFI (Deutsches Geodatisches Forschungsinstitut), in Munich, to generate weekly coordinates and velocity information of each continuous GNSS station. Since October 2006, five additional experimental processing centers - located at the Brazilian Institute of Geography and Statistics (IBGE), National Institute of Statistics, Geography and Informatics of Mexico (INEGI), Military Geographic Institute of Argentina (IGM), University of La Plata (UNLP), Argentina, and Geographic Institute Agustín Codazzi, Colombia (IGAC) - have also been processing data from those stations in order to assume the official processing responsibility in near future. Many Latin American countries have already adopted SIRGAS as their new official reference system. Besides, efforts have been carried out in order to have the national geodetic networks of Central American countries connected to the SIRGAS reference frame, which will be accomplished by a GNSS campaign scheduled for the first semester of 2007. In terms of vertical datum, SIRGAS continues to coordinate with each member country all the necessary efforts towards making the geodetic leveling data available together with gravity information in order to support the computation of geopotential numbers, to be unified in a continental adjustment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendt, Fabian F; Yu, Yi-Hsiang; Nielsen, Kim
This is the first joint reference paper for the Ocean Energy Systems (OES) Task 10 Wave Energy Converter modeling verification and validation group. The group is established under the OES Energy Technology Network program under the International Energy Agency. OES was founded in 2001 and Task 10 was proposed by Bob Thresher (National Renewable Energy Laboratory) in 2015 and approved by the OES Executive Committee EXCO in 2016. The kickoff workshop took place in September 2016, wherein the initial baseline task was defined. Experience from similar offshore wind validation/verification projects (OC3-OC5 conducted within the International Energy Agency Wind Task 30)more » [1], [2] showed that a simple test case would help the initial cooperation to present results in a comparable way. A heaving sphere was chosen as the first test case. The team of project participants simulated different numerical experiments, such as heave decay tests and regular and irregular wave cases. The simulation results are presented and discussed in this paper.« less
NASA Astrophysics Data System (ADS)
Marchand, R.; Purschke, D.; Samson, J.
2013-03-01
Understanding the physics of interaction between satellites and the space environment is essential in planning and exploiting space missions. Several computer models have been developed over the years to study this interaction. In all cases, simulations are carried out in the reference frame of the spacecraft and effects such as charging, the formation of electrostatic sheaths and wakes are calculated for given conditions of the space environment. In this paper we present a program used to compute magnetic fields and a number of space plasma and space environment parameters relevant to Low Earth Orbits (LEO) spacecraft-plasma interaction modeling. Magnetic fields are obtained from the International Geophysical Reference Field (IGRF) and plasma parameters are obtained from the International Reference Ionosphere (IRI) model. All parameters are computed in the spacecraft frame of reference as a function of its six Keplerian elements. They are presented in a format that can be used directly in most spacecraft-plasma interaction models. Catalogue identifier: AENY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AENY_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 270308 No. of bytes in distributed program, including test data, etc.: 2323222 Distribution format: tar.gz Programming language: FORTRAN 90. Computer: Non specific. Operating system: Non specific. RAM: 7.1 MB Classification: 19, 4.14. External routines: IRI, IGRF (included in the package). Nature of problem: Compute magnetic field components, direction of the sun, sun visibility factor and approximate plasma parameters in the reference frame of a Low Earth Orbit satellite. Solution method: Orbit integration, calls to IGRF and IRI libraries and transformation of coordinates from geocentric to spacecraft frame reference. Restrictions: Low Earth orbits, altitudes between 150 and 2000 km. Running time: Approximately two seconds to parameterize a full orbit with 1000 points.
KEY COMPARISON: Final Report on CCT-K7: Key comparison of water triple point cells
NASA Astrophysics Data System (ADS)
Stock, M.; Solve, S.; del Campo, D.; Chimenti, V.; Méndez-Lango, E.; Liedberg, H.; Steur, P. P. M.; Marcarino, P.; Dematteis, R.; Filipe, E.; Lobo, I.; Kang, K. H.; Gam, K. S.; Kim, Y.-G.; Renaot, E.; Bonnier, G.; Valin, M.; White, R.; Dransfield, T. D.; Duan, Y.; Xiaoke, Y.; Strouse, G.; Ballico, M.; Sukkar, D.; Arai, M.; Mans, A.; de Groot, M.; Kerkhof, O.; Rusby, R.; Gray, J.; Head, D.; Hill, K.; Tegeler, E.; Noatsch, U.; Duris, S.; Kho, H. Y.; Ugur, S.; Pokhodun, A.; Gerasimov, S. F.
2006-01-01
The triple point of water serves to define the kelvin, the unit of thermodynamic temperature, in the International System of Units (SI). Furthermore, it is the most important fixed point of the International Temperature Scale of 1990 (ITS-90). Any uncertainty in the realization of the triple point of water contributes directly to the measurement uncertainty over the wide temperature range from 13.8033 K to 1234.93 K. The Consultative Committee for Thermometry (CCT) decided at its 21st meeting in 2001 to carry out a comparison of water triple point cells and charged the BIPM with its organization. Water triple point cells from 20 national metrology institutes were carried to the BIPM and were compared with highest accuracy with two reference cells. The small day-to-day changes of the reference cells were determined by a least-squares technique. Prior to the measurements at the BIPM, the transfer cells were compared with the corresponding national references and therefore also allow comparison of the national references of the water triple point. This report presents the results of this comparison and gives detailed information about the measurements made at the BIPM and in the participating laboratories. It was found that the transfer cells show a standard deviation of 50 µK the difference between the extremes is 160 µK. The same spread is observed between the national references. The most important result of this work is that a correlation between the isotopic composition of the cell water and the triple point temperature was observed. To reduce the spread between different realizations, it is therefore proposed that the definition of the kelvin should refer to water of a specified isotopic composition. The CCT recommended to the International Committee of Weights and Measures (CIPM) to clarify the definition of the kelvin in the SI brochure by explicitly referring to water with the isotopic composition of Vienna Standard Mean Ocean Water (VSMOW). The CIPM accepted this recommendation and the next edition of the SI brochure will include this specification. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Initiating and Managing University-Based International Research and Development Activities.
ERIC Educational Resources Information Center
Peterson, Marla P.
1987-01-01
Initiating and managing international research and development are discussed, including: basic principles for participation in international development activities; AID and World Bank project cycles; AID and World Bank contracting modes and instruments; and international contract negotiations. Some reference sources are appended. (MLW)
Hackl, Andrea M; Becker, Amy B; Todd, Maureen E
2016-01-01
On August 22, 2013, Bradley Manning released a statement requesting to be referred to as female. In the following days, the news media discussed whether language should shift toward a female representation. Using quantitative content analysis and qualitative contextual analysis, this study analyzed whether U.S. and international newspapers (N = 197) acknowledged Manning's request to be referred to as "Chelsea" in the two weeks after the statement. Results suggest that the mainstream press was hesitant in shifting toward a female representation. A comparison of international and U.S. newspapers suggests that the U.S. press lagged behind international coverage using a female depiction.
Automation of film densitometry for application in personal monitoring.
Taheri, M; Movafeghi, A; Rastkhah, N
2011-03-01
In this research work, a semi-automatic densitometry system has been developed for large-scale monitoring services by use of film badge dosemeters. The system consists of a charge-coupled device (CCD)-based scanner that can scan optical densities (ODs) up to 4.2, a computer vision algorithm to improve the quality of digitised films and an analyser program to calculate the necessary information, e.g. the mean OD of region of interest and radiation doses. For calibration of the system, two reference films were used. The Microtek scanner International Color Consortium (ICC) profiler is applied for determining the colour attributes of the scanner accurately and a reference of the density step tablet, Bundesanstalt für Materialforschung und-prüfung (BAM) is used for calibrating the automatic conversion of gray-level values to OD values in the range of 0.2-4.0 OD. The system contributes to achieve more objectives and reliable results. So by applying this system, we can digitise a set of 20 films at once and calculate their relative doses less than about 4 min, and meanwhile it causes to avoid disadvantages of manual process and to enhance the accuracy of dosimetry.
Rocha-Martins, Maurício; Njaine, Brian; Silveira, Mariana S
2012-01-01
Housekeeping genes have been commonly used as reference to normalize gene expression and protein content data because of its presumed constitutive expression. In this paper, we challenge the consensual idea that housekeeping genes are reliable controls for expression studies in the retina through the investigation of a panel of reference genes potentially suitable for analysis of different stages of retinal development. We applied statistical tools on combinations of retinal developmental stages to assess the most stable internal controls for quantitative RT-PCR (qRT-PCR). The stability of expression of seven putative reference genes (Actb, B2m, Gapdh, Hprt1, Mapk1, Ppia and Rn18s) was analyzed using geNorm, BestKeeper and Normfinder software. In addition, several housekeeping genes were tested as loading controls for Western blot in the same sample panel, using Image J. Overall, for qRT-PCR the combination of Gapdh and Mapk1 showed the highest stability for most experimental sets. Actb was downregulated in more mature stages, while Rn18s and Hprt1 showed the highest variability. We normalized the expression of cyclin D1 using various reference genes and demonstrated that spurious results may result from blind selection of internal controls. For Western blot significant variation could be seen among four putative internal controls (β-actin, cyclophilin b, α-tubulin and lamin A/C), while MAPK1 was stably expressed. Putative housekeeping genes exhibit significant variation in both mRNA and protein content during retinal development. Our results showed that distinct combinations of internal controls fit for each experimental set in the case of qRT-PCR and that MAPK1 is a reliable loading control for Western blot. The results indicate that biased study outcomes may follow the use of reference genes without prior validation for qRT-PCR and Western blot.
NASA Astrophysics Data System (ADS)
Aubert, J.; Fournier, A.
2011-10-01
Over the past decades, direct three-dimensional numerical modelling has been successfully used to reproduce the main features of the geodynamo. Here we report on efforts to solve the associated inverse problem, aiming at inferring the underlying properties of the system from the sole knowledge of surface observations and the first principle dynamical equations describing the convective dynamo. To this end we rely on twin experiments. A reference model time sequence is first produced and used to generate synthetic data, restricted here to the large-scale component of the magnetic field and its rate of change at the outer boundary. Starting from a different initial condition, a second sequence is next run and attempts are made to recover the internal magnetic, velocity and buoyancy anomaly fields from the sparse surficial data. In order to reduce the vast underdetermination of this problem, we use stochastic inversion, a linear estimation method determining the most likely internal state compatible with the observations and some prior knowledge, and we also implement a sequential evolution algorithm in order to invert time-dependent surface observations. The prior is the multivariate statistics of the numerical model, which are directly computed from a large number of snapshots stored during a preliminary direct run. The statistics display strong correlation between different harmonic degrees of the surface observations and internal fields, provided they share the same harmonic order, a natural consequence of the linear coupling of the governing dynamical equations and of the leading influence of the Coriolis force. Synthetic experiments performed with a weakly nonlinear model yield an excellent quantitative retrieval of the internal structure. In contrast, the use of a strongly nonlinear (and more realistic) model results in less accurate static estimations, which in turn fail to constrain the unobserved small scales in the time integration of the evolution scheme. Evaluating the quality of forecasts of the system evolution against the reference solution, we show that our scheme can improve predictions based on linear extrapolations on forecast horizons shorter than the system e-folding time. Still, in the perspective of forthcoming data assimilation activities, our study underlines the need of advanced estimation techniques able to cope with the moderate to strong nonlinearities present in the geodynamo.
NASA Astrophysics Data System (ADS)
Kowalewska, Zofia; Ruszczyńska, Anna; Bulska, Ewa
2005-03-01
Cu was determined in a wide range of petroleum products from crude oil distillation using flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS). Different procedures of sample preparation were evaluated: (i) mineralization with sulfuric acid in an open system, (ii) mineralization in a closed microwave system, (iii) combustion in hydrogen-oxygen flame in the Wickbold's apparatus, (iv) matrix evaporation followed by acid dissolution, and (v) acidic extraction. All the above procedures led to the transfer of the analyte into an aqueous solution for the analytical measurement step. It was found that application of FAAS was limited to the analysis of the heaviest petroleum products of high Cu content. In ICP-MS, the use of internal reference method (with Rh or In as internal reference element) was required to eliminate the matrix effects in the analysis of extracts and the concentrated solutions of mineralized heavy petroleum products. The detection limits (in original samples) were equal to, respectively, 10, 86, 3.3, 0.9 and 0.4 ng g - 1 in procedures i-v with ETAAS detection and 10, 78, 1.1 and 0.5 ng g - 1 in procedures i-iii and v with ICP-MS detection. The procedures recommended here were validated by recovery experiments, certified reference materials analysis and comparison of results, obtained for a given sample, in different ways. The Cu content in the analyzed samples was: 50-110 ng g - 1 in crude oil, < 0.4-6 ng g - 1 in gasoline, < 0.5-2 ng g - 1 in atmospheric oil, < 6-100 ng g - 1 in heavy vacuum oil and 140-300 ng g - 1 in distillation residue.
Information sources in science and technology in Finland
NASA Technical Reports Server (NTRS)
Haarala, Arja-Riitta
1994-01-01
Finland poses some problems to be overcome in the field of scientific and technical information: a small user community which makes domestic systems costly; great distances within the country between users and suppliers of information; great distances to international data systems and large libraries abroad; and inadequate collections of scientific and technical information. The national bibliography Fennica includes all books and journals published in Finland. Data base services available in Finland include: reference data bases in science and technology; data banks for decision making such as statistical time series or legal proceedings; national bibliographies; and library catalogs.
Signal processing for ION mobility spectrometers
NASA Technical Reports Server (NTRS)
Taylor, S.; Hinton, M.; Turner, R.
1995-01-01
Signal processing techniques for systems based upon Ion Mobility Spectrometry will be discussed in the light of 10 years of experience in the design of real-time IMS. Among the topics to be covered are compensation techniques for variations in the number density of the gas - the use of an internal standard (a reference peak) or pressure and temperature sensors. Sources of noise and methods for noise reduction will be discussed together with resolution limitations and the ability of deconvolution techniques to improve resolving power. The use of neural networks (either by themselves or as a component part of a processing system) will be reviewed.
Tsetlin, E M; Volkova, R A
1996-01-01
Ninety-eight lots of commercial antirabies vaccine manufactured by Immunopreparat Research and Production Amalgamation have been tested using enzyme immunoassay system for the detection of rabies virus antigens. Comparison of different variants of interpreting and expressing the results helped define the optimal method for assessment of vaccine titer and reference values: optical density value equal to 0.2 is taken as the cut-off. Antigenic activity of the vaccine may be expressed in international units, similarly as immunogenic activity.
Space Geodetic Technique Co-location in Space: Simulation Results for the GRASP Mission
NASA Astrophysics Data System (ADS)
Kuzmicz-Cieslak, M.; Pavlis, E. C.
2011-12-01
The Global Geodetic Observing System-GGOS, places very stringent requirements in the accuracy and stability of future realizations of the International Terrestrial Reference Frame (ITRF): an origin definition at 1 mm or better at epoch and a temporal stability on the order of 0.1 mm/y, with similar numbers for the scale (0.1 ppb) and orientation components. These goals were derived from the requirements of Earth science problems that are currently the international community's highest priority. None of the geodetic positioning techniques can achieve this goal alone. This is due in part to the non-observability of certain attributes from a single technique. Another limitation is imposed from the extent and uniformity of the tracking network and the schedule of observational availability and number of suitable targets. The final limitation derives from the difficulty to "tie" the reference points of each technique at the same site, to an accuracy that will support the GGOS goals. The future GGOS network will address decisively the ground segment and to certain extent the space segment requirements. The JPL-proposed multi-technique mission GRASP (Geodetic Reference Antenna in Space) attempts to resolve the accurate tie between techniques, using their co-location in space, onboard a well-designed spacecraft equipped with GNSS receivers, a SLR retroreflector array, a VLBI beacon and a DORIS system. Using the anticipated system performance for all four techniques at the time the GGOS network is completed (ca 2020), we generated a number of simulated data sets for the development of a TRF. Our simulation studies examine the degree to which GRASP can improve the inter-technique "tie" issue compared to the classical approach, and the likely modus operandi for such a mission. The success of the examined scenarios is judged by the quality of the origin and scale definition of the resulting TRF.
Lenters-Westra, Erna; English, Emma
2017-08-28
As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs <3% in SI units and <2% in NGSP units at 46 mmol/mol (6.4%) and 72 mmol/mol (8.7%) and passed the NGSP criteria when compared with six secondary reference measurement procedures (SRMPs). Sigma was 8.6 for Abbott Enzymatic, 3.3 for Roche Cobas c513 and 6.9 for Tosoh G11. No clinically significant interference was detected for the common Hb variants for the three methods. All three methods performed well and are suitable for clinical application in the analysis of HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.
Host cell remodeling by pathogens: the exomembrane system in Plasmodium-infected erythrocytes
Sherling, Emma S.; van Ooij, Christiaan
2016-01-01
Malaria is caused by infection of erythrocytes by parasites of the genus Plasmodium. To survive inside erythrocytes, these parasites induce sweeping changes within the host cell, one of the most dramatic of which is the formation of multiple membranous compartments, collectively referred to as the exomembrane system. As an uninfected mammalian erythrocyte is devoid of internal membranes, the parasite must be the force and the source behind the formation of these compartments. Even though the first evidence of the presence these of internal compartments was obtained over a century ago, their functions remain mostly unclear, and in some cases completely unknown, and the mechanisms underlying their formation are still mysterious. In this review, we provide an overview of the different parts of the exomembrane system, describing the parasitophorous vacuole, the tubovesicular network, Maurer's clefts, the caveola-vesicle complex, J dots and other mobile compartments, and the small vesicles that have been observed in Plasmodium-infected cells. Finally, we combine the data into a simplified view of the exomembrane system and its relation to the alterations of the host erythrocyte. PMID:27587718
Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?
Ceriotti, Ferruccio
2018-03-30
Measurement uncertainty (MU) is a "non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used". In the clinical laboratory the most convenient way to calculate MU is the "top down" approach based on the use of Internal Quality Control data. As indicated in the definition, MU depends on the information used for its calculation and so different estimates of MU can be obtained. The most problematic aspect is how to deal with bias. In fact bias is difficult to detect and quantify and it should be corrected including only the uncertainty derived from this correction. Several approaches to calculate MU starting from Internal Quality Control data are presented. The minimum requirement is to use only the intermediate precision data, provided to include 6 months of results obtained with a commutable quality control material at a concentration close to the clinical decision limit. This approach is the minimal requirement and it is convenient for all those measurands that are especially used for monitoring or where a reference measurement system does not exist and so a reference for calculating the bias is lacking. Other formulas including the uncertainty of the value of the calibrator, including the bias from a commutable certified reference material or from a material specifically prepared for trueness verification, including the bias derived from External Quality Assessment schemes or from historical mean of the laboratory are presented and commented. MU is an important parameter, but a single, agreed upon way to calculate it in a clinical laboratory is not yet available. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Ma, Jun; Wang, Zhiqiang; Song, Yi; Hu, Peijin; Zhang, Bing
2010-12-01
To establish BMI percentile curves that describe the contemporary BMI distribution among Chinese children, and to compare their BMI percentile curves with those in two recently developed international references: the WHO and the US Centers for Disease Control and Prevention (US CDC) growth references. A cross-sectional national survey. Thirty provinces, municipalities and autonomous regions in China. Nationally representative sample of 232 140 school students aged 7-18 years. BMI percentile curves were established using the LMS method, and were compared with the percentiles of the WHO and the US CDC references. BMI distributions and growth patterns in Chinese children were dramatically different from those in the two international reference populations. Compared with the international reference populations, younger Chinese boys (7-12 years of age) had higher values of the percentiles above the median and lower values of the percentiles below the median, suggesting that they had larger proportions of extreme BMI values in both directions. Chinese girls and older Chinese boys (15-18 years of age) had substantially lower BMI percentiles than their counterparts in the reference populations, particularly those high percentiles among older age groups. The present study described the unique patterns of BMI curves at the national level, and these curves are useful as a reference for comparing different regions and for monitoring changes over time in Chinese children. Higher proportions of children with extreme values in both directions indicate that China is currently facing both an increasing level of obesity and a high level of undernutrition, simultaneously.
14 CFR 150.13 - Incorporations by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... follows: International Electrotechnical Commission (IEC) Publication No. 179, entitled “Precision Sound Level Meters,” dated 1973. (d) Availability for purchase. Published material incorporated by reference...
14 CFR 150.13 - Incorporations by reference.
Code of Federal Regulations, 2011 CFR
2011-01-01
... follows: International Electrotechnical Commission (IEC) Publication No. 179, entitled “Precision Sound Level Meters,” dated 1973. (d) Availability for purchase. Published material incorporated by reference...
Sizaret, P
1988-01-01
The main activities in international biological standardization during the 18 years that followed the first international biological standardization meeting in London in 1921 were concerned with expressing the potencies of test preparations in comparison with reference materials. After the Second World War, however, it became clear that the testing of biological substances against international reference materials was only one among several measures for obtaining safe and potent products. The activities in international biological standardization were therefore widened so that, by the strict observance of specific manufacturing and control requirements, it was possible to gain further in safety and efficacy. At the end of 1987, 42 international requirements for biological substances were available and were being used as national requirements, sometimes after minor modification, by the majority of WHO's Member States. This is of utmost importance for the worldwide use of safe and potent biological products, including vaccines.
Energy performance indicators of wastewater treatment: a field study with 17 Portuguese plants.
Silva, Catarina; Rosa, Maria João
2015-01-01
The energy costs usually represent the second largest part of the running costs of a wastewater treatment plant (WWTP). It is therefore crucial to increase the energy efficiency of these infrastructures and to implement energy management systems, where quantitative performance metrics, such as performance indicators (PIs), play a key role. This paper presents energy PIs which cover the unit energy consumption, production, net use from external sources and costs, and the results used to validate them and derive their reference values. The results of a field study with 17 Portuguese WWTPs (5-year period) were consistent with the results obtained through an international literature survey on the two key parcels of the energy balance--consumption and production. The unit energy consumption showed an overall inverse relation with the volume treated, and the reference values reflect this relation for trickling filters and for activated sludge systems (conventional, with coagulation/filtration (C/F) and with nitrification and C/F). The reference values of electrical energy production were derived from the methane generation potential (converted to electrical energy) and literature data, whereas those of energy net use were obtained by the difference between the energy consumption and production.
Wätjen, U; Benedik, L; Spasova, Y; Vasile, M; Altzitzoglou, T; Beyermann, M
2010-01-01
In anticipation of new European requirements for monitoring radioactivity concentration in drinking water, IRMM organized an interlaboratory comparison on the determination of low levels of activity concentrations (about 10-100 mBq L(-1)) of the naturally occurring radionuclides (226)Ra, (228)Ra, (234)U and (238)U in three commercially available mineral waters. Using two or three different methods with traceability to the International System of Reference (SIR), the reference values of the water samples were determined prior to the proficiency test within combined standard uncertainties of the order of 3%-10%. An overview of radiochemical separation and measurement methods used by the 45 participating laboratories are given. The results of the participants are evaluated versus the reference values. Several of the participants' results deviate by more than a factor of two from the reference values, in particular for the radium isotopes. Such erroneous analysis results may lead to a crucial omission of remedial actions on drinking water supplies or to economic loss by an unjustified action. Copyright 2009 Elsevier Ltd. All rights reserved.
On the Execution Control of HLA Federations using the SISO Space Reference FOM
NASA Technical Reports Server (NTRS)
Moller, Bjorn; Garro, Alfredo; Falcone, Alberto; Crues, Edwin Z.; Dexter, Daniel E.
2017-01-01
In the Space domain the High Level Architecture (HLA) is one of the reference standard for Distributed Simulation. However, for the different organizations involved in the Space domain (e.g. NASA, ESA, Roscosmos, and JAXA) and their industrial partners, it is difficult to implement HLA simulators (called Federates) able to interact and interoperate in the context of a distributed HLA simulation (called Federation). The lack of a common FOM (Federation Object Model) for the Space domain is one of the main reasons that precludes a-priori interoperability between heterogeneous federates. To fill this lack a Product Development Group (PDG) has been recently activated in the Simulation Interoperability Standards Organization (SISO) with the aim to provide a Space Reference FOM (SRFOM) for international collaboration on Space systems simulations. Members of the PDG come from several countries and contribute experiences from projects within NASA, ESA and other organizations. Participants represent government, academia and industry. The paper presents an overview of the ongoing Space Reference FOM standardization initiative by focusing on the solution provided for managing the execution of an SRFOM-based Federation.
Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.
Haeckel, Rainer; Wosniok, Werner
2009-01-01
Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.
The Convergence of the Twain or Titanic Collision? BI and Reference in the 1990s' Sea of Change.
ERIC Educational Resources Information Center
Rettig, James
1995-01-01
The future role, scope, and nature of bibliographic instruction (BI) and reference services at academic libraries is unresolved. Both have felt internal pressures and challenges during the past decade. It is suggested that BI and reference share tasks and become a single service. (92 references) (Author/DGM)
22 CFR 120.28 - Listing of forms referred to in this subchapter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Listing of forms referred to in this subchapter. 120.28 Section 120.28 Foreign Relations DEPARTMENT OF STATE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS PURPOSE AND DEFINITIONS § 120.28 Listing of forms referred to in this subchapter. The forms referred to in...
22 CFR 120.28 - Listing of forms referred to in this subchapter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Listing of forms referred to in this subchapter. 120.28 Section 120.28 Foreign Relations DEPARTMENT OF STATE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS PURPOSE AND DEFINITIONS § 120.28 Listing of forms referred to in this subchapter. The forms referred to in...
22 CFR 120.28 - Listing of forms referred to in this subchapter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Listing of forms referred to in this subchapter. 120.28 Section 120.28 Foreign Relations DEPARTMENT OF STATE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS PURPOSE AND DEFINITIONS § 120.28 Listing of forms referred to in this subchapter. The forms referred to in...
22 CFR 120.28 - Listing of forms referred to in this subchapter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Listing of forms referred to in this subchapter. 120.28 Section 120.28 Foreign Relations DEPARTMENT OF STATE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS PURPOSE AND DEFINITIONS § 120.28 Listing of forms referred to in this subchapter. The forms referred to in...
Simpson, Eric L; Bruin-Weller, Marjolein; Flohr, Carsten; Ardern-Jones, Michael R; Barbarot, Sebastien; Deleuran, Mette; Bieber, Thomas; Vestergaard, Christian; Brown, Sara J; Cork, Michael J; Drucker, Aaron M; Eichenfield, Lawrence F; Foelster-Holst, Regina; Guttman-Yassky, Emma; Nosbaum, Audrey; Reynolds, Nick J; Silverberg, Jonathan I; Schmitt, Jochen; Seyger, Marieke M B; Spuls, Phyllis I; Stalder, Jean-Francois; Su, John C; Takaoka, Roberto; Traidl-Hoffmann, Claudia; Thyssen, Jacob P; van der Schaft, Jorien; Wollenberg, Andreas; Irvine, Alan D; Paller, Amy S
2017-10-01
Although most patients with atopic dermatitis (AD) are effectively managed with topical medication, a significant minority require systemic therapy. Guidelines for decision making about advancement to systemic therapy are lacking. To guide those considering use of systemic therapy in AD and provide a framework for evaluation before making this therapeutic decision with the patient. A subgroup of the International Eczema Council determined aspects to consider before prescribing systemic therapy. Topics were assigned to expert reviewers who performed a topic-specific literature review, referred to guidelines when available, and provided interpretation and expert opinion. We recommend a systematic and holistic approach to assess patients with severe signs and symptoms of AD and impact on quality of life before systemic therapy. Steps taken before commencing systemic therapy include considering alternate or concomitant diagnoses, avoiding trigger factors, optimizing topical therapy, ensuring adequate patient/caregiver education, treating coexistent infection, assessing the impact on quality of life, and considering phototherapy. Our work is a consensus statement, not a systematic review. The decision to start systemic medication should include assessment of severity and quality of life while considering the individual's general health status, psychologic needs, and personal attitudes toward systemic therapies. Copyright © 2017 American Academy of Dermatology, Inc. All rights reserved.