Boomsma, Martijn F; Slouwerhof, Inge; van Dalen, Jorn A; Edens, Mireille A; Mueller, Dirk; Milles, Julien; Maas, Mario
2015-11-01
The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue.
Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A
2003-01-20
Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas
2014-01-01
Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.
Reference States and Relative Values of Internal Energy, Enthalpy, and Entropy.
ERIC Educational Resources Information Center
Fredrickson, A. G.
1983-01-01
Discusses two reference states (pure chemical compounds and pure elements at specified condition of temperature and pressure) and the relation between these reference states for internal energy and enthalpy. Problem 5.11 from Modell and Reid's "Thermodynamics and its Applications" (p. 141) is used to apply the ideas discussed. (JN)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirman, C R.; Sweeney, Lisa M.; Corley, Rick A.
2005-04-01
Reference values, including an oral reference dose (RfD) and an inhalation reference concentration (RfC), were derived for propylene glycol methyl ether (PGME), and an oral RfD was derived for its acetate (PGMEA). These values were based upon transient sedation observed in F344 rats and B6C3F1 mice during a two-year inhalation study. The dose-response relationship for sedation was characterized using internal dose measures as predicted by a physiologically based pharmacokinetic (PBPK) model for PGME and its acetate. PBPK modeling was used to account for changes in rodent physiology and metabolism due to aging and adaptation, based on data collected during weeksmore » 1, 2, 26, 52, and 78 of a chronic inhalation study. The peak concentration of PGME in richly perfused tissues was selected as the most appropriate internal dose measure based upon a consideration of the mode of action for sedation and similarities in tissue partitioning between brain and other richly perfused tissues. Internal doses (peak tissue concentrations of PGME) were designated as either no-observed-adverse-effect levels (NOAELs) or lowest-observed-adverse-effect levels (LOAELs) based upon the presence or absence of sedation at each time-point, species, and sex in the two year study. Distributions of the NOAEL and LOAEL values expressed in terms of internal dose were characterized using an arithmetic mean and standard deviation, with the mean internal NOAEL serving as the basis for the reference values, which was then divided by appropriate uncertainty factors. Where data were permitting, chemical-specific adjustment factors were derived to replace default uncertainty factor values of ten. Nonlinear kinetics are were predicted by the model in all species at PGME concentrations exceeding 100 ppm, which complicates interspecies and low-dose extrapolations. To address this complication, reference values were derived using two approaches which differ with respect to the order in which these extrapolations were performed: (1) uncertainty factor application followed by interspecies extrapolation (PBPK modeling); and (2) interspecies extrapolation followed by uncertainty factor application. The resulting reference values for these two approaches are substantially different, with values from the former approach being 7-fold higher than those from the latter approach. Such a striking difference between the two approaches reveals an underlying issue that has received little attention in the literature regarding the application of uncertainty factors and interspecies extrapolations to compounds where saturable kinetics occur in the range of the NOAEL. Until such discussions have taken place, reference values based on the latter approach are recommended for risk assessments involving human exposures to PGME and PGMEA.« less
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Ma, Jun; Wang, Zhiqiang; Song, Yi; Hu, Peijin; Zhang, Bing
2010-12-01
To establish BMI percentile curves that describe the contemporary BMI distribution among Chinese children, and to compare their BMI percentile curves with those in two recently developed international references: the WHO and the US Centers for Disease Control and Prevention (US CDC) growth references. A cross-sectional national survey. Thirty provinces, municipalities and autonomous regions in China. Nationally representative sample of 232 140 school students aged 7-18 years. BMI percentile curves were established using the LMS method, and were compared with the percentiles of the WHO and the US CDC references. BMI distributions and growth patterns in Chinese children were dramatically different from those in the two international reference populations. Compared with the international reference populations, younger Chinese boys (7-12 years of age) had higher values of the percentiles above the median and lower values of the percentiles below the median, suggesting that they had larger proportions of extreme BMI values in both directions. Chinese girls and older Chinese boys (15-18 years of age) had substantially lower BMI percentiles than their counterparts in the reference populations, particularly those high percentiles among older age groups. The present study described the unique patterns of BMI curves at the national level, and these curves are useful as a reference for comparing different regions and for monitoring changes over time in Chinese children. Higher proportions of children with extreme values in both directions indicate that China is currently facing both an increasing level of obesity and a high level of undernutrition, simultaneously.
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
Kainu, Annette; Lindqvist, Ari; Sovijärvi, Anssi R. A.
2016-01-01
Background New Finnish (Kainu2015) and international Global Lung Function Initiative (GLI2012) reference values for spirometry were recently published. The aim of this study is to compare the interpretative consequences of adopting these new reference values with older, currently used Finnish reference values (Viljanen1982) in the general population of native Finns. Methods Two Finnish general population samples including 1,328 adults (45% males) aged 21–74 years were evaluated. Airway obstruction was defined as a reduced ratio of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), possible restrictive pattern as reduced FVC, and decreased ventilatory capacity as reduced FEV1 below their respective 2.5th percentiles. The severity gradings of reduced lung function were also compared. Results Using the Kainu2015 reference values, the prevalence of airway obstruction in the population was 5.6%; using GLI2012 it was 4.0% and with Viljanen1982 it was 13.0%. Possible restrictive pattern was found in 4.2% using the Kainu2015 values, in 2.0% with GLI2012, and 7.9% with the Viljanen1982 values. The prevalence of decreased ventilatory capacity was 6.8, 4.0, and 13.3% with the Kainu2015, GLI2012 and Viljanen1982 values, respectively. Conclusions The application of the GLI2012 reference values underestimates the prevalence of abnormal spirometric findings in native Finns. The adoption of the Kainu2015 reference values reduces the prevalences of airways obstruction, decreased ventilatory capacity, and restrictive impairment by approximately 50%. Changing from the 2.5th percentile, the previously used lower limit of normal, to the 5th percentile recommended by the American Thoracic Society/European Respiratory Society will not increase the prevalence of abnormal findings in the implementation of spirometry reference values. PMID:27608270
Reference values for 27 clinical chemistry tests in 70-year-old males and females.
Carlsson, Lena; Lind, Lars; Larsson, Anders
2010-01-01
Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.
Convergence of decision rules for value-based pricing of new innovative drugs.
Gandjour, Afschin
2015-04-01
Given the high costs of innovative new drugs, most European countries have introduced policies for price control, in particular value-based pricing (VBP) and international reference pricing. The purpose of this study is to describe how profit-maximizing manufacturers would optimally adjust their launch sequence to these policies and how VBP countries may best respond. To decide about the launching sequence, a manufacturer must consider a tradeoff between price and sales volume in any given country as well as the effect of price in a VBP country on the price in international reference pricing countries. Based on the manufacturer's rationale, it is best for VBP countries in Europe to implicitly collude in the long term and set cost-effectiveness thresholds at the level of the lowest acceptable VBP country. This way, international reference pricing countries would also converge towards the lowest acceptable threshold in Europe.
ERIC Educational Resources Information Center
Linton, Dale B.
2015-01-01
In this qualitative grounded theory study, 24 participants, referred to as "third culture kids" (or TCKs), ages 18-30 years, who had previously attended international Christian schools were interviewed to determine the dispositions they valued in their teachers. Incorporating principles of grounded theory, a series of rigorous steps were…
ERIC Educational Resources Information Center
Goetz, Thomas; Frenzel, Anne C.; Hall, Nathan C.; Pekrun, Reinhard
2008-01-01
The present study focused on students' academic enjoyment as predicted by achievement in multiple academic domains. Assumptions were based on Marsh's internal/external (I/E) frame of reference model and Pekrun's control-value theory of achievement emotions, and were tested in a sample of 1380 German students from grades 5 to 10. Students' academic…
Xi, Bo; Zong, Xin'nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y T; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Romdhane, Habiba Ben; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; El Ati, Jalila; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2016-01-26
Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations. © 2015 American Heart Association, Inc.
Xi, Bo; Zong, Xin’nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M.; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y.T.; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K.; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Ben Romdhane, Habiba; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; Ati, Jalila El; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2015-01-01
Background Several distributions of country-specific blood pressure (BP) percentiles by sex, age and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limit international comparisons of prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents using seven nationally representative data (China, India, Iran, Korea, Poland, Tunisia and USA). Methods and Results Data on BP for 52,636 non-overweight children and adolescents aged 6–19 years were obtained from seven large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and USA. BP values were obtained with certified mercury sphygmomanometers in all seven countries, using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th and 99th) by age and height were estimated using the Generalized Additive Model for Location Scale and Shape (GAMLSS) model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. Compared to BP level of the 90th and 95th percentiles of the U.S. Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower while diastolic BP was similar. Conclusions These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help identify hypertensive youths in diverse populations. PMID:26671979
Hermoso, Maria; Tabacchi, Garden; Iglesia-Altaba, Iris; Bel-Serrat, Silvia; Moreno-Aznar, Luis A; García-Santos, Yurena; García-Luzardo, Ma del Rosario; Santana-Salguero, Beatriz; Peña-Quintana, Luis; Serra-Majem, Lluis; Moran, Victoria Hall; Dykes, Fiona; Decsi, Tamás; Benetou, Vassiliki; Plada, Maria; Trichopoulou, Antonia; Raats, Monique M; Doets, Esmée L; Berti, Cristiana; Cetin, Irene; Koletzko, Berthold
2010-10-01
This paper presents a review of the current knowledge regarding the macro- and micronutrient requirements of infants and discusses issues related to these requirements during the first year of life. The paper also reviews the current reference values used in European countries and the methodological approaches used to derive them by a sample of seven European and international authoritative committees from which background scientific reports are available. Throughout the paper, the main issues contributing to disparities in micronutrient reference values for infants are highlighted. The identification of these issues in relation to the specific physiological aspects of infants is important for informing future initiatives aimed at providing standardized approaches to overcome variability of micronutrient reference values across Europe for this age group. © 2010 Blackwell Publishing Ltd.
Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin
2013-05-01
To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.
Diemer, J; Quétel, C R; Taylor, P D P
2002-09-01
The contribution of the Institute for Reference Materials and Measurements to the certification of the B, Cd, Cu, Mg, and Pb content of a synthetic water sample used in Comparison 12 of the International Measurement Evaluation Programme (IMEP-12) is described. The aim of the IMEP programme is to demonstrate objectively the degree of equivalence and quality of chemical measurements of individual laboratories on the international scene by comparing them with reference ranges traceable to the SI (Système International d'Unités). IMEP is organized in support of European Union policies and helps to improve the traceability of values produced by field chemical measurement laboratories. The analytical procedure used to establish the reference values for the B, Cd, Cu, Mg, and Pb content of the IMEP-12 sample is based on inductively coupled plasma-isotope-dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. The measurements performed for the IMEP-12 study are described in detail. Focus is on the element boron, which is particularly difficult to analyze by ICP-MS because of potential problems of low sensitivity, high mass discrimination, memory effects, and abundance sensitivity. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO (International Organization for Standardization) and Eurachem guidelines. For all investigated elements with concentrations in the low micro g kg(-1) and mg kg(-1) range (corresponding to pmol kg(-1) to the high micro mol kg(-1) level), SI-traceable reference values with relative expanded uncertainties ( k=2) of less than 2 % were obtained.
Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.
2010-01-01
The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208
Conversion of ICRP male reference phantom to polygon-surface phantom
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi
2013-10-01
The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom for highly penetrating radiations such as photons and neutrons. The results of the electron beams, on the other hand, show that the dose values of the polygon-surface phantom are higher by a factor of 2-5 times than those of the ICRP reference phantom for the skin and wall organs which have large holes due to low voxel resolution. The results demonstrate that the ICRP reference phantom could provide significantly unreasonable dose values to thin or wall organs especially for weakly penetrating radiations. Therefore, when compared to the original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating radiations such as electrons and other charged particles.
van Rooyen, Yolandi; Huisman, Hugo W; Schutte, Aletta E; Eloff, Fritz C; Du Plessis, Johan L; Kruger, Annamarie; Van Rooyen, Johannes M
2015-06-01
In South Africa respiratory diseases are highly prevalent, with cardiovascular disease being a manifestation. However, international reference values for lung function are commonly used, which may not be appropriate to correctly identify reduced lung function. An inverse relationship exists between lung function and blood pressure (BP) but is not investigated extensively in black South Africans. We included 2010 Africans from the PURE (Prospective Urban Rural Epidemiology) study (aged > 35 years) in the North West Province. Spirometry was performed and predicted values for forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were calculated from South African, European and United States prediction equations. With the exception of the European predicted values, all other predicted mean FEV1 and FVC were above 80%. South African reference values displayed the highest percentages of the predicted values for FEV1 and FVC (87.9 and 99.7%, respectively.) BP increased from quintiles five to one for both FEV1 and FVC, (p for trend <0.001). After adjustment the differences remained (p<0.05). South African reference values yielded higher percentages of predicted FEV1 and FVC values than European and US equations suggesting that South African prediction equations may be more useful when investigating lung function in black South Africans. Elevated BP is related to reduced lung function, highlighting the importance in managing both respiratory- and cardiovascular disease. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Acharya, R.; Swain, K. K.; Reddy, A. V. R.
2010-10-01
Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.
A Survey of New Zealand Academic Reference Librarians: Current and Future Skills and Competencies
ERIC Educational Resources Information Center
Chawner, Brenda; Oliver, Gillian
2013-01-01
A survey of New Zealand academic subject/reference librarians was conducted in mid-2011 to identify the most highly valued knowledge, skills and competencies of reference librarians working in libraries in the tertiary sector. The project was part of an international collaborative project involving 13 countries. The results from New Zealand show…
Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan
2012-09-01
A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.
Meija, Juris; Chartrand, Michelle M G
2018-01-01
Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.
Villalobos Reyes, Marjorie; Mederico, Maracelly; Paoli de Valeri, Mariela; Briceño, Yajaira; Zerpa, Yajaira; Gómez-Pérez, Roald; Camacho, Nolis; Martínez, José Luis; Valeri, Lenín; Arata-Bellabarba, Gabriela
2014-11-01
To obtain local reference values for blood lipids and blood pressure (BP), and to determine the prevalence of metabolic syndrome (MS) in children and adolescents from Mérida, Venezuela, and to compare results using local and international cut-off values. The study enrolled 916 participants of both sexes aged 9-18 years of age from educational institutions. Demographic, anthropometric, and BP data were collected. Fasting blood glucose and lipid profile were measured. Percentile distribution of lipid and BP values was done by age group and sex. Prevalence of MS was estimated based on the NCEP-ATPIII classification (as modified by Cook et al.) and the classification of the International Diabetes Federation, using percentiles of Mérida and the USA as cut-off points. Agreement between both classifications was estimated using the kappa test (κ). Prevalence of MS was 2.2% by Cook-Merida percentiles, as compared to 1.8% by Cook-USA percentiles, a moderate agreement (κ=0.54). Agreement between Cook et al. and IDF using Merida percentiles was weak (κ=0.28). There was a higher frequency of abdominal obesity, hypertriglyceridemia and hypertension, and a lower frequency of low HDL-C using Mérida percentiles. The risk (odds ratio) of having MS is greater if abdominal obesity exists (OR: 98.63, CI: 22.45-433.35, p=0.0001). MS was significantly more common in obese subjects (18.3%, p=0.0001). Prevalence of MS in this sample of children and adolescents was 2.2%. Lipid and BP values were lower in Venezuelan as compared to US, European, and Asian children and adolescents, and similar to those in Latin-American references. Own reference values are required for accurate diagnosis of MS, as well as a worldwide consensus on its diagnostic criteria. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.
Giving Your Patrons the World: Barriers to, and the Value of, International Interlibrary Loan
ERIC Educational Resources Information Center
Munson, Kurt; Thompson, Hilary H.
2018-01-01
Using the 2011 and 2015 survey by the Reference and User Services Association Sharing and Transforming Access to Resources Section (RUSA STARS) of international interlibrary loans (ILL), the authors explore barriers to this method of meeting patrons' information needs. They evaluate international ILL in the context of developments in the…
Zimmermann, Michael B; Hess, Sonja Y; Molinari, Luciano; De Benoist, Bruno; Delange, François; Braverman, Lewis E; Fujieda, Kenji; Ito, Yoshiya; Jooste, Pieter L; Moosa, Khairya; Pearce, Elizabeth N; Pretell, Eduardo A; Shishiba, Yoshimasa
2004-02-01
Goiter prevalence in school-age children is an indicator of the severity of iodine deficiency disorders (IDDs) in a population. In areas of mild-to-moderate IDDs, measurement of thyroid volume (Tvol) by ultrasound is preferable to palpation for grading goiter, but interpretation requires reference criteria from iodine-sufficient children. The study aim was to establish international reference values for Tvol by ultrasound in 6-12-y-old children that could be used to define goiter in the context of IDD monitoring. Tvol was measured by ultrasound in 6-12-y-old children living in areas of long-term iodine sufficiency in North and South America, central Europe, the eastern Mediterranean, Africa, and the western Pacific. Measurements were made by 2 experienced examiners using validated techniques. Data were log transformed, used to calculate percentiles on the basis of the Gaussian distribution, and then transformed back to the linear scale. Age- and body surface area (BSA)-specific 97th percentiles for Tvol were calculated for boys and girls. The sample included 3529 children evenly divided between boys and girls at each year ( +/- SD age: 9.3 +/- 1.9 y). The range of median urinary iodine concentrations for the 6 study sites was 118-288 micro g/L. There were significant differences in age- and BSA-adjusted mean Tvols between sites, which suggests that population-specific references in countries with long-standing iodine sufficiency may be more accurate than is a single international reference. However, overall differences in age- and BSA-adjusted Tvols between sites were modest relative to the population and measurement variability, which supports the use of a single, site-independent set of references. These new international reference values for Tvol by ultrasound can be used for goiter screening in the context of IDD monitoring.
Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W
2014-11-01
A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.
Taylor, C M; Golding, J; Emond, A M
2014-02-01
For heavy metals that have any degree of transfer though the placenta to the fetus, it is unlikely that there are safe limits for maternal blood levels. The only means of reducing fetal exposure is to minimise maternal exposure. There are few recommendations for levels of concern. With the exception of US recommendations for maternal Pb levels, but there are no international levels of concern or cut-off levels specifically for pregnancy for heavy metals, so that comparisons can generally only be made with national reference values relating to similar physiological statuses or age groups. These include recommendations for Cd levels by Germany (reference value for non-smoking adults aged 18-69 years, 1 µg/l) and for Hg by Germany (reference value for adults age 18-60 years with fish intake < or =3 times per month, 2.0 µg/l) and the USA (cut-off level for women, 5.8 µg/dl). To illustrate the lack of cohesion, we present data on blood Pb, Cd and Hg levels from pregnant women enroled in the UK Avon Longitudinal Study of Parents and Children study and compare the values with present levels of concern and recommended cut-off values. We also compare the levels with those found in other groups of pregnant women worldwide to strengthen the database for the development of levels of concern in pregnancy. The need for clarity of terminology in describing levels of concern is discussed. There is a pressing need for international consensus on levels of concern for all age groups and physiological statuses, particularly for pregnancy.
Fibrinolysis standards: a review of the current status.
Thelwell, C
2010-07-01
Biological standards are used to calibrate measurements of components of the fibrinolytic system, either for assigning potency values to therapeutic products, or to determine levels in human plasma as an indicator of thrombotic risk. Traditionally WHO International Standards are calibrated in International Units based on consensus values from collaborative studies. The International Unit is defined by the response activity of a given amount of the standard in a bioassay, independent of the method used. Assay validity is based on the assumption that both standard and test preparation contain the same analyte, and the response in an assay is a true function of this analyte. This principle is reflected in the diversity of source materials used to prepare fibrinolysis standards, which has depended on the contemporary preparations they were employed to measure. With advancing recombinant technology, and improved analytical techniques, a reference system based on reference materials and associated reference methods has been recommended for future fibrinolysis standards. Careful consideration and scientific judgement must however be applied when deciding on an approach to develop a new standard, with decisions based on the suitability of a standard to serve its purpose, and not just to satisfy a metrological ideal. 2010 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.
The environmental zero-point problem in evolutionary reaction norm modeling.
Ergon, Rolf
2018-04-01
There is a potential problem in present quantitative genetics evolutionary modeling based on reaction norms. Such models are state-space models, where the multivariate breeder's equation in some form is used as the state equation that propagates the population state forward in time. These models use the implicit assumption of a constant reference environment, in many cases set to zero. This zero-point is often the environment a population is adapted to, that is, where the expected geometric mean fitness is maximized. Such environmental reference values follow from the state of the population system, and they are thus population properties. The environment the population is adapted to, is, in other words, an internal population property, independent of the external environment. It is only when the external environment coincides with the internal reference environment, or vice versa, that the population is adapted to the current environment. This is formally a result of state-space modeling theory, which is an important theoretical basis for evolutionary modeling. The potential zero-point problem is present in all types of reaction norm models, parametrized as well as function-valued, and the problem does not disappear when the reference environment is set to zero. As the environmental reference values are population characteristics, they ought to be modeled as such. Whether such characteristics are evolvable is an open question, but considering the complexity of evolutionary processes, such evolvability cannot be excluded without good arguments. As a straightforward solution, I propose to model the reference values as evolvable mean traits in their own right, in addition to other reaction norm traits. However, solutions based on an evolvable G matrix are also possible.
dos Santos, Sabrina Novaes; Alleoni, Luís Reynaldo Ferracciú
2013-07-01
Guideline values are used to identify polluted or contaminated areas based on background values. Brazilian law establishes three guideline values for pollutants: a quality reference value (QRV), a prevention value, and an intervention value. Reference values refer to the natural concentration of an element or a substance in soils that have not been modified by anthropogenic impacts. These values inform assessments of soil quality and are used to establish maximum permissible limits. The objective of this study was to determine the natural levels and reference values for Cd, Co, Cr, Cu, Ni, Pb, and Zn in samples from the surface layer (0-20 cm) of 19 representative soils of the states of Mato Grosso and Rondônia, on Brazil's agricultural frontier. Pseudo-total metal concentrations were obtained following microwave-assisted digestion using the aqua regia and EPA3051 methods. QRVs were calculated for each element as the 75th and 90th percentiles of the frequency distribution of the data. Natural levels of heavy metals in the soil samples followed the order: Cr > Zn > Cu > Co > Pb > Ni > and Cd (aqua regia) and Cr > Co > Cu > Pb > Zn > Ni > Cd (EPA3051). These values are generally lower than those reported in the Brazilian and international literature, which highlights the importance of establishing reference values for each state or for each soil type, taking into account the geomorphological, pedological, and geological diversity of the region under study.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Towards a first realization of the International Height Reference System (IHRS)
NASA Astrophysics Data System (ADS)
Sanchez, Laura; Ihde, Johannes; Pail, Roland; Gruber, Thomas; Barzaghi, Riccardo; Marti, Urs; Agren, Jonas; Sideris, Michael; Novak, Pavel
2017-04-01
The IAG Resolution No. 1 released during the IUGG 2015 General Assembly outlines five conventions for the definition of the International Height Reference System (IHRS). The definition is given in terms of potential parameters: the vertical coordinates are geopotential numbers referring to an equipotential surface of the Earth's gravity field realized by the conventional value W0 = 62 636 853.4 m2s-2. The spatial reference of the position P for the potential W(P) = W(X) is given by coordinates X of the International Terrestrial Reference Frame (ITRF). This Resolution also states that parameters, observations, and data shall be related to the mean tidal system/mean crust. At present, the main challenge is the realization of the IHRS; i.e., the establishment of the International Height Reference Frame (IHRF). It is expected that the IHRF follows the same structure as the ITRF: a global network with regional and national densifications, whose geopotential numbers referring to the global IHRS are known. According to the GGOS objectives, the target accuracy of these global geopotential numbers is 1 x 10-2 m2s-2. In practice, the precise realization of the IHRS is limited by different aspects; for instance, no unified standards or methods for the determination of the potential values W(P); application of different conventions for the gravity field modelling and the estimation of the position vectors X; inhomogeneous distribution of the geodetic infrastructure; restricted accessibility to terrestrial gravity data to increase the GGM resolution; insufficient modelling of geodynamic phenomena, etc. This may restrict the expected accuracy of 1 x 10-2 m2s-2 to some orders lower (from 10 x 10-2 m2s-2 to 100 x 10-2 m2s-2). This contribution discusses the required steps to outline a sustainable realization of the IHRS.
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Learning about Global Interdependence: An Area-Value Mapping Exercise.
ERIC Educational Resources Information Center
Crooker, Richard A.
1990-01-01
Presents a lesson for secondary school students that uses an area value map to increase student understanding about the geography of international drug production and consumption. Provides a list of necessary classroom materials, suggested background readings for students, procedures to be followed, and a bibliography of references. (DB)
International Education in Japan: Response of the Grass-Eaters
ERIC Educational Resources Information Center
Carpenter, Walter
2012-01-01
This paper reviews some of the reasons why a majority of Japanese university students are not interested in study-abroad, international-education type programs. A general consensus in Japan is that disinterest in studying abroad is reflective of the values held by many Japanese young people, often referred to as the "grass-eating"…
Baracco, A; Coggiola, M; Discalzi, G; Perrelli, F; Romano, C
2009-01-01
Italian law on safety at work does not clarify specific levels of load for safe manual material handling. For this reason professionals appointed for safety need to define new target range value for the correct application of D.Lgs. 81/2008 law. Authors, discussing about indication of the national laws and international rules, suggest the assumption of a load of 25 and 20 kg as reference values for male and female adult and healthy workers. They also examine the graduation of the acceptable loads in relation to workers' age and the Lifting Index values to be adopted as action limit and exposure limit.
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
Byrdwell, William Craig
2014-08-01
An "extract-filter-shoot" method for the analysis of vitamin D2, ergocalciferol, in a dry powdered dietary supplement capsule containing rice flour excipient and in a National Institute of Standards and Technology standard reference material 3280 is reported. Quantification of vitamin D2 was done by atmospheric pressure chemical ionization mass spectrometry using selected ion monitoring, two transitions of selected reaction monitoring, and extracted ion chromatograms from full scans. UV detection was used for the quantification of Vitamin D2 in the dry powder capsule, whereas interfering species rendered UV detection unreliable for standard reference material 3280. Average values for standard reference material 3280 ranged from 8.27 ± 0.58 to 8.33 ± 0.57 μg/g using internal standard calibration and response factor approaches, compared to the previous National Institute of Standards and Technology internal value for vitamin D2 of 8.78 ± 0.11 μg/g, and the recently updated reference value of 8.6 ± 2.6 μg/g. The powdered supplement capsule was found to contain 28.19 ± 0.35 to 28.67 ± 0.90 μg/capsule for a capsule labeled to contain 25.00 μg. The triacylglycerol composition of the rice flour excipient in the powdered supplement capsule determined by atmospheric pressure chemical ionization mass spectrometry is also reported. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Khoury, Cheryl; Werry, Kate; Haines, Douglas; Walker, Mike; Malowany, Morie
2018-05-01
The Canadian Health Measures Survey collects nationally representative human biomonitoring data on a suite of chemicals and their metabolites, including many non-persistent chemicals. Data has been collected on non-persistent chemicals, including acrylamide, chlorophenols, environmental phenols and triclocarban, organophosphate insecticides, phthalates, polycyclic aromatic hydrocarbon, pyrethroid insecticides, and volatile organic compounds from 2009 to 2013. Using a systematic approach building on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry, we derive human biomonitoring reference values (RV 95 s) for these classes of non-persistent chemicals in blood and urine for the general Canadian population. RV 95 s were derived for biomarkers of non-persistent chemicals with widespread detection in Canadians (>66% detection rate). Samples with urinary creatinine levels outside the recommended range of 0.3-3.0 μg/L were excluded. Reference populations were constructed by applying smoking and fasting as exclusion criteria where appropriate. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for sub-populations in cases where partitioning was deemed necessary. Reference values were derived for 40 biomarkers and represent the first set of RV 95 s for non-persistent chemicals in the general Canadian population. These values provide a measure of the upper margin of background exposure in the general population and can be compared against individual and population human biomonitoring data. RV 95 s can be used to by public health officials to identify individuals with high exposures, and by risk assessors and risk managers to identify atypical exposures or subpopulations with elevated exposures. Crown Copyright © 2018. Published by Elsevier GmbH. All rights reserved.
Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.
2014-01-01
RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer.
Antigenic value of lyophilized phenolized antirabies vaccine.
VEERARAGHAVAN, N; SUBRAHMANYAN, T P
1961-01-01
The authors present the results of experiments, carried out at the Pasteur Institute of Southern India, Coonoor, in which various preparations of lyophilized and liquid phenolized antirabies vaccines were assessed for antigenicity in relation to the NIH (United States National Institutes of Health) Reference Vaccine 164 (the proposed International Reference Preparation of Rabies Vaccine). The claim that phenolized antirabies vaccines can be lyophilized without loss of antigenicity was fully substantiated: the lyophilized vaccines were found to possess high antigenic values and to retain their antigenicity better than the liquid vaccines during storage under the same conditions.
ERIC Educational Resources Information Center
Wang, Cheng-Cai; Chen, Chin-Tsu; Chen, Chun-Fu
2012-01-01
This study aimed to discuss the relationships among the brand image of universities (external variables), university satisfaction (mediating variables) and customer lifetime value (internal variables). The findings can serve as a reference for higher educational institutions in strengthening their advantages and overcoming their shortcomings, as…
The Current SI Seen From the Perspective of the Proposed New SI
Taylor, Barry N.
2011-01-01
A revised International System of Units (SI) proposed by the International Committee for Weights and Measures is under consideration by the General Conference on Weights and Measures for eventual adoption. Widely recognized as a significant advance for both metrology and science, it is defined via statements that explicitly fix the numerical values of a selected set of seven reference constants when the values of these constants are expressed in certain specified units. At first sight this approach to defining a system of units appears to be quite different from that used to define the current SI. However, by showing how the definitions of the seven base units of the current SI also fix the numerical values of a set of seven reference constants (broadly interpreted) when the values of these constants are expressed in their coherent SI units, and how the definition of the current SI can be recast into the same form as that of the revised SI under consideration, we show that the revision is not as radical a departure from the current SI as it might initially seem. PMID:26989600
Standardization for oxygen isotope ratio measurement - still an unsolved problem.
Kornexl; Werner; Gehre
1999-07-01
Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.
The Role of International Service-Learning in Facilitating Undergraduate Students' Self-Exploration
ERIC Educational Resources Information Center
Yang, Min; Luk, Lillian Yun Yung; Webster, Beverley Joyce; Chau, Albert Wai-lap; Ma, Carol Hok Ka
2016-01-01
This article examines the role of international service-learning (ISL) in facilitating undergraduates' exploration of their conceptions of self (i.e., self-exploration). Conception of self refers to the use of values to define one's role in a social/cultural group or organization and in society, and to determine current actions and future…
Brown, Kerry A; de Wit, Liesbeth; Timotijevic, Lada; Sonne, Anne-Mette; Lähteenmäki, Liisa; Brito Garcia, Noé; Jeruszka-Bielak, Marta; Sicińska, Ewa; Moore, Alana N; Lawrence, Mark; Raats, Monique M
2015-06-01
Transparent evidence-based decision making has been promoted worldwide to engender trust in science and policy making. Yet, little attention has been given to transparency implementation. The degree of transparency (focused on how uncertain evidence was handled) during the development of folate and vitamin D Dietary Reference Values was explored in three a priori defined areas: (i) value request; (ii) evidence evaluation; and (iii) final values. Qualitative case studies (semi-structured interviews and desk research). A common protocol was used for data collection, interview thematic analysis and reporting. Results were coordinated via cross-case synthesis. Australia and New Zealand, Netherlands, Nordic countries, Poland, Spain and UK. Twenty-one interviews were conducted in six case studies. Transparency of process was not universally observed across countries or areas of the recommendation setting process. Transparency practices were most commonly seen surrounding the request to develop reference values (e.g. access to risk manager/assessor problem formulation discussions) and evidence evaluation (e.g. disclosure of risk assessor data sourcing/evaluation protocols). Fewer transparency practices were observed to assist with handling uncertainty in the evidence base during the development of quantitative reference values. Implementation of transparency policies may be limited by a lack of dedicated resources and best practice procedures, particularly to assist with the latter stages of reference value development. Challenges remain regarding the best practice for transparently communicating the influence of uncertain evidence on the final reference values. Resolving this issue may assist the evolution of nutrition risk assessment and better inform the recommendation setting process.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-03-01
A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-01-01
Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
Saravanabhavan, Gurusankar; Werry, Kate; Walker, Mike; Haines, Douglas; Malowany, Morie; Khoury, Cheryl
2017-03-01
Human biomonitoring reference values are statistical estimates that indicate the upper margin of background exposure to a given chemical at a given time. Nationally representative human biomonitoring data on 176 chemicals, including several metals and trace elements, are available in Canada from 2007 to 2013 through the Canadian Health Measures Survey (CHMS). In this work, we used a systematic approach based on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry to derive reference values (RV 95 s) for metals and trace elements. These RV 95 s were derived for blood and urine matrices in the general Canadian population based on the latest biomonitoring data from the CHMS. Biomarkers were chosen based on specific selection criteria, including widespread detection in Canadians (≥66% detection rate). Reference populations were created for each biomarker by applying appropriate exclusion criteria. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for the sub-populations in cases where partitioning was deemed necessary. The RV 95 s for metals and trace elements in blood ranged from 0.18μg/L for cadmium in young children aged 3-5 years to 7900μg/L for zinc in males aged 20-79 years. In the case of urinary biomarkers, the RV 95 s ranged from 0.17μg/L for antimony in the total population aged 3-79 years to 1400mg/L for fluoride in adults aged 20-79 years. These RV 95 s represent the first set of reference values for metals and trace elements in the general Canadian population. We compare the RV 95 s from other countries where available and discuss factors that could influence such comparisons. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.
Extended international (IOTF) body mass index cut-offs for thinness, overweight and obesity.
Cole, T J; Lobstein, T
2012-08-01
The international (International Obesity Task Force; IOTF) body mass index (BMI) cut-offs are widely used to assess the prevalence of child overweight, obesity and thinness. Based on data from six countries fitted by the LMS method, they link BMI values at 18 years (16, 17, 18.5, 25 and 30 kg m(-2)) to child centiles, which are averaged across the countries. Unlike other BMI references, e.g. the World Health Organization (WHO) standard, these cut-offs cannot be expressed as centiles (e.g. 85th). To address this, we averaged the previously unpublished L, M and S curves for the six countries, and used them to derive new cut-offs defined in terms of the centiles at 18 years corresponding to each BMI value. These new cut-offs were compared with the originals, and with the WHO standard and reference, by measuring their prevalence rates based on US and Chinese data. The new cut-offs were virtually identical to the originals, giving prevalence rates differing by < 0.2% on average. The discrepancies were smaller for overweight and obesity than for thinness. The international and WHO prevalences were systematically different before/after age 5. Defining the international cut-offs in terms of the underlying LMS curves has several benefits. New cut-offs are easy to derive (e.g. BMI 35 for morbid obesity), and they can be expressed as BMI centiles (e.g. boys obesity = 98.9th centile), allowing them to be compared with other BMI references. For WHO, median BMI is relatively low in early life and high at older ages, probably due to its method of construction. © 2012 The Authors. Pediatric Obesity © 2012 International Association for the Study of Obesity.
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, M; Wang, Y; Weng, H
Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less
Cameron, A; Ewen, M; Ross-Degnan, D; Ball, D; Laing, R
2009-01-17
WHO and Health Action International (HAI) have developed a standardised method for surveying medicine prices, availability, affordability, and price components in low-income and middle-income countries. Here, we present a secondary analysis of medicine availability in 45 national and subnational surveys done using the WHO/HAI methodology. Data from 45 WHO/HAI surveys in 36 countries were adjusted for inflation or deflation and purchasing power parity. International reference prices from open international procurements for generic products were used as comparators. Results are presented for 15 medicines included in at least 80% of surveys and four individual medicines. Average public sector availability of generic medicines ranged from 29.4% to 54.4% across WHO regions. Median government procurement prices for 15 generic medicines were 1.11 times corresponding international reference prices, although purchasing efficiency ranged from 0.09 to 5.37 times international reference prices. Low procurement prices did not always translate into low patient prices. Private sector patients paid 9-25 times international reference prices for lowest-priced generic products and over 20 times international reference prices for originator products across WHO regions. Treatments for acute and chronic illness were largely unaffordable in many countries. In the private sector, wholesale mark-ups ranged from 2% to 380%, whereas retail mark-ups ranged from 10% to 552%. In countries where value added tax was applied to medicines, the amount charged varied from 4% to 15%. Overall, public and private sector prices for originator and generic medicines were substantially higher than would be expected if purchasing and distribution were efficient and mark-ups were reasonable. Policy options such as promoting generic medicines and alternative financing mechanisms are needed to increase availability, reduce prices, and improve affordability.
Isometric Shoulder Strength Reference Values for Physically Active Collegiate Males and Females
Westrick, Richard B.; Duffey, Michele L.; Cameron, Kenneth L.; Gerber, J. Parry; Owens, Brett D.
2013-01-01
Background: It is common clinical practice to assess muscle strength during examination of patients following shoulder injury or surgery. Strength comparisons are often made between the patient’s injured and uninjured shoulders, with the uninjured side used as a reference without regard to upper extremity dominance. Despite the importance of strength measurements, little is known about expected normal baselines of the uninjured shoulder. The purpose of this study was to report normative values for isometric shoulder strength for physically active college-age men and women without history of shoulder injury. Methods: University students—546 males (18.8 ± 1.0 years, 75.3 ± 12.2 kg) and 73 females (18.7 ± 0.9 years, 62.6 ± 7.0 kg)—underwent thorough shoulder evaluations by an orthopaedic surgeon and completed bilateral isometric strength measurements with a handheld dynamometer. Variables measured included internal rotation, external rotation, abduction, supine internal rotation and external rotation at 45°, and lower trapezius in prone flexion. Results: Significant differences were found between the dominant and nondominant shoulder for internal rotation, internal rotation at 45°, abduction, and prone flexion in males and in internal rotation at 45° and prone flexion for females (P ≤ 0.01). PMID:24381696
ERIC Educational Resources Information Center
Nagy, Gabriel; Trautwein, Ulrich; Baumert, Jurgen; Koller, Olaf; Garrett, Jessica
2006-01-01
Predictions about processes linking gender to students' choices of advanced courses were derived from the internal/external frame of reference (I/E) model and expectancy value (EV) theory. The predictions were tested for the domains of mathematics and biology using data from 1,148 students attending academically oriented secondary schools in…
Korean anatomical reference data for adults for use in radiological protection
NASA Astrophysics Data System (ADS)
Choi, Chansoo; Yeom, Yeon Soo; Nguyen, Thang Tat; Lee, Hanjin; Han, Haegin; Shin, Bangho; Zhang, Xujia; Kim, Chan Hyeong; Chung, Beom Sun
2018-01-01
For radiological protection from exposure to ionizing radiation, in which a population-averaged dose evaluation is used, establishing a system of reference anatomical and physiological data for a specific population of interest is important. Some studies were done in the past to establish Korean reference data; however, the data provided the mass values only for a limited number of organs/tissues. In addition, the standing height and total body mass are based on 20-year-old data. In the present study, a new set of Korean reference anatomical values was established for use in the radiological protection of Korean workers and members of the public. The established Korean reference data provide the masses of 58 organs/tissues, including those needed to calculate the effective dose, which were derived by collecting and analyzing various scientific reports in the literature and data. In addition, the data provide not only standing height and total body mass, but also 131 additional anthropometric parameters; these values were derived from the most recent Korean national survey project, 7 th Size Korea. The characteristics of the data were also compared with several other population data, including the Asian and the International Commission on Radiological Protection (ICRP) reference data.
Estimating clinical chemistry reference values based on an existing data set of unselected animals.
Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe
2008-11-01
In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.
2017-01-01
As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.
Calhoun, Peter; Lum, John; Beck, Roy W; Kollman, Craig
2013-09-01
Knowledge of the accuracy of continuous glucose monitoring (CGM) devices is important for its use as a management tool for individuals with diabetes and for its use to assess outcomes in clinical studies. Using data from several inpatient studies, we compared the accuracy of two sensors, the Medtronic Enlite™ using MiniMed Paradigm(®) Veo™ calibration and the Sof-Sensor(®) glucose sensor using Guardian(®) REAL-Time CGM calibration (all from Medtronic Diabetes, Northridge, CA). Nocturnal data were analyzed from eight inpatient studies in which both CGM and reference glucose measurements were available. The analyses included 1,666 CGM-reference paired glucose values for the Enlite in 54 participants over 69 nights and 3,627 paired values for the Sof-Sensor in 66 participants over 91 nights. The Enlite sensor tended to report glucose levels lower than the reference over the entire range of glucose values, whereas the Sof-Sensor values tended to be higher than reference values in the hypoglycemic range and lower than reference values in the hyperglycemic range. The overall median sensor-reference difference was -15 mg/dL for the Enlite and -1 mg/dL for the Sof-Sensor (P<0.001). The median relative absolute difference was 15% for the Enlite versus 12% for the Sof-Sensor (P=0.06); 66% of Enlite values and 73% of Sof-Sensor values met International Organization for Standardization criteria. We found that the Enlite tended to be biased low over the entire glucose range, whereas the Sof-Sensor showed the more typical sensor pattern of being biased high in the hypoglycemic range and biased low in the hyperglycemic range.
Antigenic value of lyophilized phenolized antirabies vaccine
Veeraraghavan, N.; Subrahmanyan, T. P.
1961-01-01
The authors present the results of experiments, carried out at the Pasteur Institute of Southern India, Coonoor, in which various preparations of lyophilized and liquid phenolized antirabies vaccines were assessed for antigenicity in relation to the NIH (United States National Institutes of Health) Reference Vaccine 164 (the proposed International Reference Preparation of Rabies Vaccine). The claim that phenolized antirabies vaccines can be lyophilized without loss of antigenicity was fully substantiated: the lyophilized vaccines were found to possess high antigenic values and to retain their antigenicity better than the liquid vaccines during storage under the same conditions. PMID:13925168
A proposed International Geomagnetic Reference Field for 1965- 1985.
Peddie, N.W.; Fabiano, E.B.
1982-01-01
A set of spherical harmonic models describing the Earth's main magnetic field from 1965 to 1985 has been developed and is proposed as the next revision of the International Geomagnetic Reference Field (IGRF). A tenth degree and order spherical harmonic model of the main field was derived from Magsat data. A series of eighth degree and order spherical harmonic models of the secular variation of the main field was derived from magnetic observatory annual mean values. Models of the main field at 1965, 1970, 1975, and 1980 were obtained by extrapolating the main-field model using the secular variation models.-Authors spherical harmonic models Earth main magnetic field Magsat data
Al-Raees, Ghada Y; Al-Amer, Maryam A; Musaiger, Abdulrahman O; D'Souza, Reshma
2009-01-01
A cross-sectional study was carried out on Bahraini preschoolers aged 2-5 years (354 males and 344 females) to determine the prevalence of overweight and obesity using the World Health Organization and the International Obesity Task Force cut-off values. Weight and height were recorded and body mass index (BMI) was calculated to determine the proportion of overweight and obesity. Using the World Health Organization percentile cut-off values, overweight (12.3%) and obesity (8.4%) was higher in females between 2 and <4 years of age whereas, the proportion of both overweight (8.4%) and obesity (7.2%) were higher in males between 4 and <6 years of age. Relative to the International Obesity Task Force indicators, the World Health Organization cut-off values produced nearly a 2-fold increase in both overweight and obesity at most ages. It is therefore important to ensure that the same cut-off reference values are used to define overweight and obesity particularly in preschoolers. Shifting to the new World Health Organization child growth standards may have important implications for child health programmes.
Koho, Petteri; Borodulin, Katja; Kautiainen, Hannu; Kujala, Urho; Pohjolainen, Timo; Hurri, Heikki
2015-03-01
To create reference values for the general Finnish population using the Tampa Scale of Kinesiophobia (TSK-FIN), to study gender differences in the TSK-FIN, to assess the internal consistency of the TSK-FIN, to estimate the prevalence of high levels of kinesiophobia in Finnish men and women, and to examine the association between kinesiophobia and leisure-time physical activity and the impact of co-morbidities on kinesiophobia. The study population comprised 455 men and 579 women. Participants completed a self-administered questionnaire about their socio-demographic factors, leisure-time physical activity, co-morbidities and kinesiophobia. The mean TSK-FIN score was significantly higher for men (mean 34.2, standard deviation (SD) 6.9) compared with women (mean 32.9, SD 6.5), with an age-adjusted p = 0.004 for the difference between men and women. Cronbach's alpha was 0.72, indicating substantial internal consistency. Men over 55 years of age and women over 65 years of age had a higher (p < 0.001) TSK score compared with younger people. There was a significant (p < 0.001) inverse association between kinesiophobia and leisure-time physical activity among both sexes. The presence of cardiovascular disease, musculoskeletal disease or a mental disorder was associated with a higher TSK-FIN score compared with the absence of the aforementioned disorders. We present here the reference values for the TSK-FIN. The reference values and prevalence among the general population may help clinicians to define the level of kinesiophobia among patients. Disorders other than musculoskeletal diseases were associated with kinesiophobia, which should be noted in daily practice.
Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.
Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W
2016-02-26
Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.
Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B
2014-10-15
As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
Kokubun, Norito; Sonoo, Masahiro; Imai, Tomihiro; Arimura, Yumiko; Kuwabara, Satoshi; Komori, Tetsuo; Kobayashi, Masahito; Nagashima, Takahide; Hatanaka, Yuki; Tsuda, Emiko; Misawa, Sonoko; Abe, Tatsuya; Arimura, Kimiyoshi
2012-03-01
The aim of this study is to establish reference values for single-fibre electromyography (SFEMG) using concentric needles in a prospective, multicentre study. Voluntary or stimulated SFEMG at the extensor digitorum communis (EDC) or frontalis (FRO) muscles was conducted in 56-63 of a total of 69 normal subjects below the age of 60years at six Japanese institutes. The cut-off values for mean consecutive difference (MCD) of individual potentials were calculated using +2.5 SD or 95% prediction limit (one-tail) of the upper 10th percentile MCD value for individual subjects. The cut-off values for individual MCD (+2.5 SD) were 56.8μs for EDC-V (voluntary SFEMG for EDC), 58.8μs for EDC-S (stimulated SFEMG for EDC), 56.8μs for FRO-V (voluntary SFEMG for FRO) and 51.0μs for FRO-S (stimulated SFEMG for FRO). The false positive rates using these cut-off values were around 2%. The +2.5 SD and 95% prediction limit might be two optimal cut-off values, depending on the clinical question. The obtained reference values were larger than those reported previously using concentric needles, but might better coincide with conventional values. This is the first multicentre study reporting reference values for SFEMG using concentric needles. The way to determine cut-off values and the statistically correct definition of the percentile were discussed. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Xie, Tianwu; Kuster, Niels; Zaidi, Habib
2017-07-13
Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms while the argument for individualized patient-specific radiation dosimetry exists. This study aims to evaluate the influence of body habitus on internal dosimetry and to quantify the uncertainties in dose estimation correlated with the use of fixed reference models. The 5-year-old IT'IS male phantom was modified to match target anthropometric parameters, including body weight, body height and sitting height/stature ratio (SSR), determined from reference databases, thus enabling the creation of 125 5-year-old habitus-dependent male phantoms with 10th, 25th, 50th, 75th and 90th percentile body morphometries. We evaluated the absorbed fractions and the mean absorbed dose to the target region per unit cumulative activity in the source region (S-values) of F-18 in 46 source regions for the generated 125 anthropomorphic 5-year-old hybrid male phantoms using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code and calculated the absorbed dose and effective dose of five 18 F-labelled radiotracers for children of various habitus. For most organs, the S-value of F-18 presents stronger statistical correlations with body weight, standing height and sitting height than BMI and SSR. The self-absorbed fraction and self-absorbed S-values of F-18 and the absorbed dose and effective dose of 18 F-labelled radiotracers present with the strongest statistical correlations with body weight. For 18 F-Amino acids, 18 F-Brain receptor substances, 18 F-FDG, 18 F-L-DOPA and 18 F-FBPA, the mean absolute effective dose differences between phantoms of different habitus and fixed reference models are 11.4%, 11.3%, 10.8%, 13.3% and 11.4%, respectively. Total body weight, standing height and sitting height have considerable effects on human internal dosimetry. Radiation dose calculations for individual subjects using the most closely matched habitus-dependent computational phantom should be considered as an alternative to improve the accuracy of the estimates.
NASA Astrophysics Data System (ADS)
Xie, Tianwu; Kuster, Niels; Zaidi, Habib
2017-08-01
Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms while the argument for individualized patient-specific radiation dosimetry exists. This study aims to evaluate the influence of body habitus on internal dosimetry and to quantify the uncertainties in dose estimation correlated with the use of fixed reference models. The 5-year-old IT’IS male phantom was modified to match target anthropometric parameters, including body weight, body height and sitting height/stature ratio (SSR), determined from reference databases, thus enabling the creation of 125 5-year-old habitus-dependent male phantoms with 10th, 25th, 50th, 75th and 90th percentile body morphometries. We evaluated the absorbed fractions and the mean absorbed dose to the target region per unit cumulative activity in the source region (S-values) of F-18 in 46 source regions for the generated 125 anthropomorphic 5-year-old hybrid male phantoms using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code and calculated the absorbed dose and effective dose of five 18F-labelled radiotracers for children of various habitus. For most organs, the S-value of F-18 presents stronger statistical correlations with body weight, standing height and sitting height than BMI and SSR. The self-absorbed fraction and self-absorbed S-values of F-18 and the absorbed dose and effective dose of 18F-labelled radiotracers present with the strongest statistical correlations with body weight. For 18F-Amino acids, 18F-Brain receptor substances, 18F-FDG, 18F-L-DOPA and 18F-FBPA, the mean absolute effective dose differences between phantoms of different habitus and fixed reference models are 11.4%, 11.3%, 10.8%, 13.3% and 11.4%, respectively. Total body weight, standing height and sitting height have considerable effects on human internal dosimetry. Radiation dose calculations for individual subjects using the most closely matched habitus-dependent computational phantom should be considered as an alternative to improve the accuracy of the estimates.
Coplen, T.B.; Friedman, Irving; O'Neil, J.R.
1984-01-01
According to U.S. Geological Survey records, a report prepared by R. Gonfiantini summarizing the findings and recommendations of the 1983 Advisory Group Meeting on Stable Isotope Reference Samples for Geochemical and Hydrologic Investigations held in Vienna does not accurately represent the consultants ' consensus on three important points. The consultants (1) recommended no value for the C02-H20 oxygen isotope fractionation factor, not the cited value of 1.04115, (2) adopted a value of 1.0309 rather than 1.03086 to relate the PDB and SMOW scales, and (3) adopted a firm 180 value of -2.20% for NBS-19 on the PDB scale rather than agreeing that this would be a tentative value subject to modification when more measurements in selected laboratories are available. (USGS)
Kulaga, Zbigniew; Litwin, Mieczysław; Tkaczyk, Marcin; Rózdzyńska, Agnieszka; Barwicka, Katarzyna; Grajda, Aneta; Swiader, Anna; Gurzkowska, Beata; Napieralska, Ewelina; Pan, Huiqi
2010-03-04
The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used.
2010-01-01
Background The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Methods Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Results Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. Conclusions In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used. PMID:20199693
Wätjen, U; Benedik, L; Spasova, Y; Vasile, M; Altzitzoglou, T; Beyermann, M
2010-01-01
In anticipation of new European requirements for monitoring radioactivity concentration in drinking water, IRMM organized an interlaboratory comparison on the determination of low levels of activity concentrations (about 10-100 mBq L(-1)) of the naturally occurring radionuclides (226)Ra, (228)Ra, (234)U and (238)U in three commercially available mineral waters. Using two or three different methods with traceability to the International System of Reference (SIR), the reference values of the water samples were determined prior to the proficiency test within combined standard uncertainties of the order of 3%-10%. An overview of radiochemical separation and measurement methods used by the 45 participating laboratories are given. The results of the participants are evaluated versus the reference values. Several of the participants' results deviate by more than a factor of two from the reference values, in particular for the radium isotopes. Such erroneous analysis results may lead to a crucial omission of remedial actions on drinking water supplies or to economic loss by an unjustified action. Copyright 2009 Elsevier Ltd. All rights reserved.
Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.
Haeckel, Rainer; Wosniok, Werner
2009-01-01
Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.
International comparison of activity measurements of a solution of 75Se
NASA Astrophysics Data System (ADS)
Ratel, Guy
2002-04-01
Activity measurements of a solution of 75Se, supplied by the BIPM, have been carried out by 21 laboratories within the framework of an international comparison. Seven different methods were used. Details on source preparation, experimental facilities and counting data are reported. The measured activity-concentration values show a total spread of 6.62% before correction and 6.02% after correction for delayed events, with standard deviations of the unweighted means of 0.45% and 0.36%, respectively. The correction for delayed events was measured directly by four laboratories. Unfortunately no consensus on the activity value could be deduced from their results. The results of the comparison have been entered in the tables of the International Reference System (SIR) for γ-ray emitting radionuclides. The half-life of the metastable state was also determined by two laboratories and found to be in good agreement with the values found in the literature.
Beauchet, Olivier; Allali, Gilles; Sekhon, Harmehr; Verghese, Joe; Guilain, Sylvie; Steinmetz, Jean-Paul; Kressig, Reto W.; Barden, John M.; Szturm, Tony; Launay, Cyrille P.; Grenier, Sébastien; Bherer, Louis; Liu-Ambrose, Teresa; Chester, Vicky L.; Callisaya, Michele L.; Srikanth, Velandai; Léonard, Guillaume; De Cock, Anne-Marie; Sawa, Ryuichi; Duque, Gustavo; Camicioli, Richard; Helbostad, Jorunn L.
2017-01-01
Background: Gait disorders, a highly prevalent condition in older adults, are associated with several adverse health consequences. Gait analysis allows qualitative and quantitative assessments of gait that improves the understanding of mechanisms of gait disorders and the choice of interventions. This manuscript aims (1) to give consensus guidance for clinical and spatiotemporal gait analysis based on the recorded footfalls in older adults aged 65 years and over, and (2) to provide reference values for spatiotemporal gait parameters based on the recorded footfalls in healthy older adults free of cognitive impairment and multi-morbidities. Methods: International experts working in a network of two different consortiums (i.e., Biomathics and Canadian Gait Consortium) participated in this initiative. First, they identified items of standardized information following the usual procedure of formulation of consensus findings. Second, they merged databases including spatiotemporal gait assessments with GAITRite® system and clinical information from the “Gait, cOgnitiOn & Decline” (GOOD) initiative and the Generation 100 (Gen 100) study. Only healthy—free of cognitive impairment and multi-morbidities (i.e., ≤ 3 therapeutics taken daily)—participants aged 65 and older were selected. Age, sex, body mass index, mean values, and coefficients of variation (CoV) of gait parameters were used for the analyses. Results: Standardized systematic assessment of three categories of items, which were demographics and clinical information, and gait characteristics (clinical and spatiotemporal gait analysis based on the recorded footfalls), were selected for the proposed guidelines. Two complementary sets of items were distinguished: a minimal data set and a full data set. In addition, a total of 954 participants (mean age 72.8 ± 4.8 years, 45.8% women) were recruited to establish the reference values. Performance of spatiotemporal gait parameters based on the recorded footfalls declined with increasing age (mean values and CoV) and demonstrated sex differences (mean values). Conclusions: Based on an international multicenter collaboration, we propose consensus guidelines for gait assessment and spatiotemporal gait analysis based on the recorded footfalls, and reference values for healthy older adults. PMID:28824393
Tohidi, Maryam; Ghasemi, Asghar; Hadaegh, Farzad; Derakhshan, Arash; Chary, Abdolreza; Azizi, Fereidoun
2014-04-01
Increased insulin concentration is a surrogate for insulin resistance and early assessment of fasting insulin may help in identifying those who are potentially at high risk of type 2 diabetes, hypertension, and cardiovascular disease. The aim of this study was to determine age- and sex-related reference values for serum insulin and insulin resistance/sensitivity indices in Iranian subjects. Serum insulin levels were measured by electrochemiluminescence immunoassay in 5786 participants of the Tehran Lipid and Glucose Study. After application of exclusion criteria, 309 non-obese healthy subjects (124 men and 185 women), aged 24-83 y, were included. The International Federation of Clinical Chemistry guidelines (non-parametric method) and the robust method were used for determining reference values. Overall 95% reference values for fasting insulin were 1.61-11.37, 2.34-11.98, and 2.11-12.49 μU/mL in men, women, and total population respectively. Mean fasting insulin concentration showed a decreasing trend with age in both genders (p for trend ≤0.001). Age, waist circumference, and systolic blood pressures were biological determinants of fasting insulin in both genders; in addition, insulin was modulated by triglycerides in men and fasting glucose in women. Reference intervals for HOMA1-IR, HOMA2-IR, and QUICKI were 0.63-2.68, 0.40-1.80, and 0.33-0.42, respectively. This study presents the first set of reference values for fasting serum insulin to be 2-12 μU/mL for both genders in a healthy sample of Iranian adults along with the reference values for insulin resistance/sensitivity indices. These values could be used for identifying subjects with insulin resistance in epidemiological and clinical research. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.
2011-01-01
In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Nerve ultrasound normal values - Readjustment of the ultrasound pattern sum score UPSS.
Grimm, Alexander; Axer, Hubertus; Heiling, Bianka; Winter, Natalie
2018-07-01
Reference values are crucial for nerve ultrasound. Here, we reevaluated normal nerve and fascicle cross-sectional area (CSA) values in humans and compared them to published values. Based on these data, ultrasound pattern sum score (UPSS) boundary values were revisited and readjusted. Ultrasound of different peripheral nerves was performed in 100 healthy subjects at anatomically defined landmarks. Correlations with age, gender, height and weight were calculated. Overall, correspondence to other published reference values was high. Gender-dependency was found for the proximal median nerve. Dependency from height occurred in the tibial nerve (TN). Weight-dependency was not found. However, the most obvious differences were found in the TN between men >60 years and women <60 years. Thus, general boundary values were defined using the mean plus the twofold standard deviation for all subjects and nerve segments except for the TN, in which different cut-offs were proposed for elder men. Accordingly, the cut-offs for the UPSS were re-adjusted, none of the individuals revealed more than 2 points at maximum. The influence of distinct epidemiological factors on nerve size is most prominent in the TN, for which thus several normal values are useful. Adjusted reference values improve the accuracy of the UPSS. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
New reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.
1993-01-01
Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.
Hemingway, B.S.
1982-01-01
Thermodynamic values for 110 uranium-bearing phases and 28 aqueous uranium solution species (298.15 K and l bar) are tabulated based upon evaluated experimental data (largely from calorimetric experiments) and estimated values. Molar volume data are given for most of the solid phases. Thermodynamic values for 16 uranium-bearing phases are presented for higher temperatures in the form of and as a supplement to U.S. Geological Survey Bulletin 1452 (Robie et al., 1979). The internal consistency of the thermodynamic values reported herein is dependent upon the reliability of the experimental results for several uranium phases that have been used as secondary calorimetric reference phases. The data for the reference phases and for those phases evaluated with respect to the secondary reference phases are discussed. A preliminary model for coffinite formation has been proposed together with an estimate of the free energy of formation of coffinite. Free energy values are estimated for several other uranium-bearing silicate phases that have been reported as secondary uranium phases associated with uranium ore deposits and that could be expected to develop wherever uranium is leached by groundwaters.
Binetti, R; Costamagna, F M; Marcello, I
2001-01-01
International, national and regulatory classification, evaluation, guidelines and occupational exposure values regarding vinyl chloride and 1,2-dichloroethane, carried out by European Union (EU). Environmental Protection Agency (US EPA), International Agency for Research on Cancer (IARC), Italian National Advisory Toxicological Committee (CCTN), Occupational Safety and Health Administration (OSHA), World Health Organization (WHO), National Institute for Occupational Safety and Health (NIOSH), American Conference of Governmental Industrial Hygienists (ACGIH) and other institutions, have been considered with particular reference to the carcinogenic effects. Moreover information is reported in support of classification and evaluation and a short historical review since early 1970s, when first evidence that occupational exposure to VC could lead to angiosarcoma was published.
Neville, David C A; Alonzi, Dominic S; Butters, Terry D
2012-04-13
Hydrophilic interaction liquid chromatography (HILIC) of fluorescently labelled oligosaccharides is used in many laboratories to analyse complex oligosaccharide mixtures. Separations are routinely performed using a TSK gel-Amide 80 HPLC column, and retention times of different oligosaccharide species are converted to glucose unit (GU) values that are determined with reference to an external standard. However, if retention times were to be compared with an internal standard, consistent and more accurate GU values would be obtained. We present a method to perform internal standard-calibrated HILIC of fluorescently labelled oligosaccharides. The method relies on co-injection of 4-aminobenzoic acid ethyl ester (4-ABEE)-labelled internal standard and detection by UV absorption, with 2-AA (2-aminobenzoic acid)-labelled oligosaccharides. 4-ABEE is a UV chromophore and a fluorophore, but there is no overlap of the fluorescent spectrum of 4-ABEE with the commonly used fluorescent reagents. The dual nature of 4-ABEE allows for accurate calculation of the delay between UV and fluorescent signals when determining the GU values of individual oligosaccharides. The GU values obtained are inherently more accurate as slight differences in gradients that can influence retention are negated by use of an internal standard. Therefore, this paper provides the first method for determination of HPLC-derived GU values of fluorescently labelled oligosaccharides using an internal calibrant. Copyright © 2012 Elsevier B.V. All rights reserved.
The International Standard for Oxytetracycline
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1955-01-01
The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard. Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg. PMID:13284563
González Jiménez, E; Aguilar Cordero, M J; Álvarez Ferre, J; Padilla López, C; Valenza, M C
2012-01-01
Recent studies show an alarming increase in levels of overweight and obesity among children and adolescents. The main objectives of this research were the following: (i) to carry out an anthropometric evaluation of the nutritional status and body composition of school children in the city and province of Granada; (ii) to compare the nutritional status of this population sample with national and international reference standards. The results obtained in this study showed that the general prevalence of overweight in both sexes was 22.03% and that 9.12% of the children were obese. Statistically significant differences were found between the variable, weight for age and sex (p < 0.05) and the variable, height for age and sex (p < 0.05). Regarding the body mass index, no statistically significant differences were found for the variable, sex (p = 0.182). This contrasted with the variable, age, which did show statistically significant differences (p < 0.05). As a conclusion, the results of our study highlighted the fact that these anthropometric values were much higher than national and international reference standards.
Bibbo, Giovanni; Brown, Scott; Linke, Rebecca
2016-08-01
Diagnostic Reference Levels (DRL) of procedures involving ionizing radiation are important tools to optimizing radiation doses delivered to patients and in identifying cases where the levels of doses are unusually high. This is particularly important for paediatric patients undergoing computed tomography (CT) examinations as these examinations are associated with relatively high-dose. Paediatric CT studies, performed at our institution from January 2010 to March 2014, have been retrospectively analysed to determine the 75th and 95th percentiles of both the volume computed tomography dose index (CTDIvol ) and dose-length product (DLP) for the most commonly performed studies to: establish local diagnostic reference levels for paediatric computed tomography examinations performed at our institution, benchmark our DRL with national and international published paediatric values, and determine the compliance of CT radiographer with established protocols. The derived local 75th percentile DRL have been found to be acceptable when compared with those published by the Australian National Radiation Dose Register and two national children's hospitals, and at the international level with the National Reference Doses for the UK. The 95th percentiles of CTDIvol for the various CT examinations have been found to be acceptable values for the CT scanner Dose-Check Notification. Benchmarking CT radiographers shows that they follow the set protocols for the various examinations without significant variations in the machine setting factors. The derivation of DRL has given us the tool to evaluate and improve the performance of our CT service by improved compliance and a reduction in radiation dose to our paediatric patients. We have also been able to benchmark our performance with similar national and international institutions. © 2016 The Royal Australian and New Zealand College of Radiologists.
Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki
2010-09-15
Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Influence of echo time in quantitative proton MR spectroscopy using LCModel.
Yamamoto, Tetsuya; Isobe, Tomonori; Akutsu, Hiroyoshi; Masumoto, Tomohiko; Ando, Hiroki; Sato, Eisuke; Takada, Kenta; Anno, Izumi; Matsumura, Akira
2015-06-01
The objective of this study was to elucidate the influence on quantitative analysis using LCModel with the condition of echo time (TE) longer than the recommended values in the spectrum acquisition specifications. A 3T magnetic resonance system was used to perform proton magnetic resonance spectroscopy. The participants were 5 healthy volunteers and 11 patients with glioma. Data were collected at TE of 72, 144 and 288ms. LCModel was used to quantify several metabolites (N-acetylaspartate, creatine and phosphocreatine, and choline-containing compounds). The results were compared with quantitative values obtained by using the T2-corrected internal reference method. In healthy volunteers, when TE was long, the quantitative values obtained using LCModel were up to 6.8-fold larger (p<0.05) than those obtained using the T2-corrected internal reference method. The ratios of the quantitative values obtained by the two methods differed between metabolites (p<0.05). In patients with glioma, the ratios of quantitative values obtained by the two methods tended to be larger at longer TE, similarly to the case of healthy volunteers, and large between-individual variation in the ratios was observed. In clinical practice, TE is sometimes set longer than the value recommended for LCModel. If TE is long, LCModel overestimates the quantitative value since it cannot compensate for signal attenuation, and this effect is different for each metabolite and condition. Therefore, if TE is longer than recommended, it is necessary to account for the possibly reduced reliability of quantitative values calculated using LCModel. Copyright © 2015 Elsevier Inc. All rights reserved.
The role of menaquinones (vitamin K2) in human health
USDA-ARS?s Scientific Manuscript database
International Life Sciences Institute (ILSI) Europe convened experts in vitamin K selected from academia and industry to review the need for specific dietary reference values (DRVs) for vitamin K2, also known as menaquinones. This review describes the literature based on the following items required...
NASA Astrophysics Data System (ADS)
Kutelia, E. R.; Dzigrashvili, T. A.; Kukava, T. G.; Darsavelidze, G. Sh.; Kurashvili, I. R.; Riedel, H.; Donth, B.
2017-02-01
The present research is dealing with the comparative study of inelastic/elastic behavior of reference ˜12%Cr steel ZL3 and three new trial steels ZU1, ZU2, ZU3, with different ratio of alloying elements and equal content of Cr, using internal friction measurements. The samples were examined in "as-received" condition and after additional electric current tempering at 700˚C under different fixed external mechanical tensions. The values of deformation critical amplitudes for dislocation breakaway (ɛ1) and for microplastic deformation beginning (ɛ2) were determined in addition to the activation energies of relaxation processes in the investigated steels. It is shown that all the three trial steel samples in "as-received" condition exhibit considerably higher values of ɛ2 in comparison to those of reference ZL3 steel. Among them the ZU3 steel has the highest values of ɛ1 and ɛ2, and demonstrates the visible (˜40%) increase in strength characteristics at elevated temperatures (600÷750˚C), achieved by the additional electric current tempering under mechanical tension.
Broughton, Heather M; Govender, Danny; Shikwambana, Purvance; Chappell, Patrick; Jolles, Anna
2017-06-01
The International Species Information System has set forth an extensive database of reference intervals for zoologic species, allowing veterinarians and game park officials to distinguish normal health parameters from underlying disease processes in captive wildlife. However, several recent studies comparing reference values from captive and free-ranging animals have found significant variation between populations, necessitating the development of separate reference intervals in free-ranging wildlife to aid in the interpretation of health data. Thus, this study characterizes reference intervals for six biochemical analytes, eleven hematologic or immune parameters, and three hormones using samples from 219 free-ranging African lions ( Panthera leo ) captured in Kruger National Park, South Africa. Using the original sample population, exclusion criteria based on physical examination were applied to yield a final reference population of 52 clinically normal lions. Reference intervals were then generated via 90% confidence intervals on log-transformed data using parametric bootstrapping techniques. In addition to the generation of reference intervals, linear mixed-effect models and generalized linear mixed-effect models were used to model associations of each focal parameter with the following independent variables: age, sex, and body condition score. Age and sex were statistically significant drivers for changes in hepatic enzymes, renal values, hematologic parameters, and leptin, a hormone related to body fat stores. Body condition was positively correlated with changes in monocyte counts. Given the large variation in reference values taken from captive versus free-ranging lions, it is our hope that this study will serve as a baseline for future clinical evaluations and biomedical research targeting free-ranging African lions.
USDA-ARS?s Scientific Manuscript database
A previous workshop had reviewed the development of the Codex Alimentarius (Codex) and its central role in protecting the health of consumers and ensuring fair practices in international food trade. This workshop further reviewed how Codex promotes harmonization and consensus by promoting the coordi...
Critical Challenges and Dilemmas for Catholic Education Leadership Internationally
ERIC Educational Resources Information Center
Gleeson, Jim
2015-01-01
This paper considers the challenges faced by contemporary Catholic Education systems with particular reference to the contrast between the prevailing neo-liberal agenda and gospel values. It explicates this contrast from the perspectives of current critiques of the influence of the new manageralism in education and relevant literature on Catholic…
Teaching Science Out-of-School with Special Reference to Biology.
ERIC Educational Resources Information Center
Meyer, G. Rex, Ed.; Rao, A. N., Ed.
This book contains a selection of previously unpublished papers from an international Asian symposium on out-of-school science activities. These papers include: "Educational and Social Values of Out-of-School Science" (Peter Kelly); "School Versus Out-of-School: An Artificial Dichotomy" (William Mayer); "Biology of…
The Costs of Reneging: Reputation and Alliance Formation
ERIC Educational Resources Information Center
Gibler, Douglas M.
2008-01-01
Reputations are supposed to matter. Decision makers consistently refer to reputations for resolve, and international relations theories confirm the value of being able to credibly signal intentions during times of crisis. However, empirical support for the effects of reputation has been lacking. Problems of strategic selection have hampered…
How the reference values for serum parathyroid hormone concentration are (or should be) established?
Souberbielle, J-C; Brazier, F; Piketty, M-L; Cormier, C; Minisola, S; Cavalier, E
2017-03-01
Well-validated reference values are necessary for a correct interpretation of a serum PTH concentration. Establishing PTH reference values needs recruiting a large reference population. Exclusion criteria for this population can be defined as any situation possibly inducing an increase or a decrease in PTH concentration. As recommended in the recent guidelines on the diagnosis and management of asymptomatic primary hyperparathyroidism, PTH reference values should be established in vitamin D-replete subjects with a normal renal function with possible stratification according to various factors such as age, gender, menopausal status, body mass index, and race. A consensus about analytical/pre-analytical aspects of PTH measurement is also needed with special emphasis on the nature of the sample (plasma or serum), the time and the fasting/non-fasting status of the blood sample. Our opinion is that blood sample for PTH measurement should be obtained in the morning after an overnight fast. Furthermore, despite longer stability of the PTH molecule in EDTA plasma, we prefer serum as it allows to measure calcium, a prerequisite for a correct interpretation of a PTH concentration, on the same sample. Once a consensus is reached, we believe an important international multicentre work should be performed to recruit a very extensive reference population of apparently healthy vitamin D-replete subjects with a normal renal function in order to establish the PTH normative data. Due to the huge inter-method variability in PTH measurement, a sufficient quantity of blood sample should be obtained to allow measurement with as many PTH kits as possible.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B; Brand, Willi A; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita T; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A J; Sauer, Peter E; Sessions, Alex L; Werner, Roland A
2016-04-19
An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B.; Brand, Willi A.; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F.; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A.J.; Sauer, Peter E.; Sessions, Alex L.; Werner, Roland A.
2016-01-01
An international project developed, quality-tested, and determined isotope−δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope−δ scales. The RMs span a range of δ2HVSMOW-SLAP values from −210.8 to +397.0 mUr or ‰, for δ13CVPDB-LSVEC from −40.81 to +0.49 mUr and for δ15NAir from −5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ2H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain 13C and carbon-bound organic 2H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
The production and certification of a plutonium equal-atom reference material: NBL CRM 128
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, D.W.; Gradle, C.G.; Soriano, M.D.
This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less
Chin, Kok-Yong; Ima-Nirwana, Soelaiman; Isa Naina, Mohamed; Norazlina, Mohamed; Ahmad Nazrun, Shuid; Norliza, Muhammad; Faizah, Othman; Farihah, H Suhaimi; Elvy Suhana, Mohd Ramli; Wan Zurinah, Wan Ngah
2012-01-01
Quantitative ultrasound (QUS) is a relatively easy, reliable, and safe method for bone status assessment, but reference data for Asian males remain scarce. Our study aimed to determine the values for one QUS parameter, the speed of sound (SOS) at the calcaneus, in Malaysian Chinese men and to determine the association between the SOS and several demographic characteristics, such as age, weight, height, and body mass index. Three hundred forty-eight Malaysian Chinese men aged 40 yr and older were recruited, and their calcaneal QUS value was determined using the CM-200 densitometer (Furuno Electric, Nishinomiya City, Japan). The results indicated a significant correlation between SOS and age, and multiple stepwise regression analysis indicated that age and height were important predictors of SOS. A significant reduction in SOS value was observed when men 60 yr and older were compared with men aged 40-49 yr. Compared with the reference data for Japanese males, Chinese men in Malaysia showed higher SOS values across all the age groups studied. In conclusion, there is an age-related decrease in SOS values in Malaysian Chinese men, and the SOS values established in this study can be used as a reference for future studies. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Payande, Abolfazl; Tabesh, Hamed; Shakeri, Mohammad Taghi; Saki, Azadeh; Safarian, Mohammad
2013-01-14
Growth charts are widely used to assess children's growth status and can provide a trajectory of growth during early important months of life. The objectives of this study are going to construct growth charts and normal values of weight-for-age for children aged 0 to 5 years using a powerful and applicable methodology. The results compare with the World Health Organization (WHO) references and semi-parametric LMS method of Cole and Green. A total of 70737 apparently healthy boys and girls aged 0 to 5 years were recruited in July 2004 for 20 days from those attending community clinics for routine health checks as a part of a national survey. Anthropometric measurements were done by trained health staff using WHO methodology. The nonparametric quantile regression method obtained by local constant kernel estimation of conditional quantiles curves using for estimation of curves and normal values. The weight-for-age growth curves for boys and girls aged from 0 to 5 years were derived utilizing a population of children living in the northeast of Iran. The results were similar to the ones obtained by the semi-parametric LMS method in the same data. Among all age groups from 0 to 5 years, the median values of children's weight living in the northeast of Iran were lower than the corresponding values in WHO reference data. The weight curves of boys were higher than those of girls in all age groups. The differences between growth patterns of children living in the northeast of Iran versus international ones necessitate using local and regional growth charts. International normal values may not properly recognize the populations at risk for growth problems in Iranian children. Quantile regression (QR) as a flexible method which doesn't require restricted assumptions, proposed for estimation reference curves and normal values.
Payande, Abolfazl; Tabesh, Hamed; Shakeri, Mohammad Taghi; Saki, Azadeh; Safarian, Mohammad
2013-01-01
Introduction: Growth charts are widely used to assess children’s growth status and can provide a trajectory of growth during early important months of life. The objectives of this study are going to construct growth charts and normal values of weight-for-age for children aged 0 to 5 years using a powerful and applicable methodology. The results compare with the World Health Organization (WHO) references and semi-parametric LMS method of Cole and Green. Methods: A total of 70737 apparently healthy boys and girls aged 0 to 5 years were recruited in July 2004 for 20 days from those attending community clinics for routine health checks as a part of a national survey. Anthropometric measurements were done by trained health staff using WHO methodology. The nonparametric quantile regression method obtained by local constant kernel estimation of conditional quantiles curves using for estimation of curves and normal values. Results: The weight-for-age growth curves for boys and girls aged from 0 to 5 years were derived utilizing a population of children living in the northeast of Iran. The results were similar to the ones obtained by the semi-parametric LMS method in the same data. Among all age groups from 0 to 5 years, the median values of children’s weight living in the northeast of Iran were lower than the corresponding values in WHO reference data. The weight curves of boys were higher than those of girls in all age groups. Conclusion: The differences between growth patterns of children living in the northeast of Iran versus international ones necessitate using local and regional growth charts. International normal values may not properly recognize the populations at risk for growth problems in Iranian children. Quantile regression (QR) as a flexible method which doesn’t require restricted assumptions, proposed for estimation reference curves and normal values. PMID:23618470
The CIPM list of recommended frequency standard values: guidelines and procedures
NASA Astrophysics Data System (ADS)
Riehle, Fritz; Gill, Patrick; Arias, Felicitas; Robertsson, Lennart
2018-04-01
A list of standard reference frequency values (LoF) of quantum transitions from the microwave to the optical regime has been recommended by the International Committee for Weights and Measures (Comité international des poids et mesures, CIPM) for use in basic research, technology, and for the metrology of time, frequency and length. The CIPM LoF contains entries that are recommended as secondary representations of the second in the International System of Units, and entries that can be used to serve as realizations of the definition of the metre. The historical perspective that led to the CIPM LoF is outlined. Procedures have been developed for updating existing, and validating new, entries into the CIPM LoF. The CIPM LoF might serve as an entry for a future redefinition of the second by an optical transition.
[Body mass index charts of Algerian children and adolescents (6-18 years)].
Bahchachi, N; Dahel-Mekhancha, C-C; Rolland-Cachera, M-F; Roelants, M; Hauspie, R; Nezzal, L
2017-12-01
The body mass index (BMI) is widely accepted as a measure of overweight and obesity in children. There are no BMI reference charts for Algerian children and adolescents. The purpose of this study was to construct BMI percentile curves appropriate for children aged 6-18 years in Algeria. The weight and height of 7772 (54.9% girls) healthy schoolchildren from Constantine (eastern Algeria) were measured in 2008/2009. Weight and height for age curves based on the same sample were published previously. The BMI for age percentile curves were estimated in girls and boys separately using the LMS smoothing method. In both sexes, the median BMI increased with age. Girls had lower BMI values than boys before the age of 10 years but they were higher after this age until 18 years of age. Within the study population, the prevalence of overweight (including obesity) and obesity in girls and boys together was 13.7% and 3.0%, respectively, according to the International Obesity Task Force (IOTF) and 16.9% and 4.9% according to the World Health Organization (WHO) (2007). The median BMI curves of Algerian girls and boys were generally lower than those observed in other Arab countries. Compared with other references, the median BMI values of girls were lower than those of a Belgian Flemish population and WHO 2007 until 14 years of age and higher than the French reference between 7 and 18 years of age. The BMI values of Algerian boys were close to the Belgian (Flemish population), French and WHO 2007 references between 6 and 9 years of age and generally lower thereafter. These BMI curves are complementary to the height and weight charts published previously for the assessment of growth in children and adolescents. They were developed according to international guidelines and could serve as a national reference. They could be used as a complement to the 0- to 5-year-old WHO 2006 standards. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Zhang, Kejun; Wang, Feng; Zhang, Mingxu; Cao, Xinglu; Yang, Shaojun; Jia, Shuangrong; Wang, Lixin; Luo, Jie; Deng, Shaoli; Chen, Ming
2016-11-01
The enumeration of lymphocyte subsets plays an essential role in the monitoring of immunological disorders. Immunophenotyping values have been found to be influenced by race, age, gender, and environmental conditions. Therefore, it is important to establish reference ranges for healthy adults from the local population for clinical decision-making. The current study aimed to establish a normal reference range for peripheral blood lymphocyte subsets in healthy adults from the Chongqing District of China by using single-platform flow cytometry. Age- and gender-specific reference ranges were established in 268 healthy adult males and females between 21 and 60 years of age. The CD8+ cell counts decreased with age, CD4+ cell percentages and counts increased with age, and total T cell percentages were higher in the female population. Our results are similar to those reported from other parts of China but different from some results reported from other countries; this further stresses the need to establish local reference ranges by region. Our results will help in the management of patients with human immunodeficiency virus and other immunological disorders in Chongqing District. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.
[Current problems in determining children's nutritional needs].
Koletzko, B; Toschke, A M; Von Kries, R
2004-03-01
Meeting children's nutritional needs is of fundamental importance for their immediate and later health, well-being, and performance. Age-adapted reference values of nutrient intake form the basis for analysis of the current situation and for policy planning, but for many nutrients they cannot be precisely defined due to inadequate scientific data. Therefore, such values are often extrapolated from adult reference values based on age-adapted mean body weight or body surface data, although such extrapolation does not reflect age-related physiological changes. There are considerable differences between various expert recommendations, in part also due to differences in definitions and underlying concepts for deriving reference values. Improvements and international harmonization are urgently needed. Nutritional needs of many children and adolescents are not adequately met at present. A particularly obvious indication is the epidemic-like increase of pediatric overweight and obesity, which could result in markedly increased prevalences of later metabolic syndrome, diabetes, and cardiovascular diseases. Contributing to increasing childhood obesity are low physical activity, changing eating culture and behavior, frequent consumption of high-fat foods with high energy density, and increasing portion sizes. Changes are urgently needed and might be achievable with close collaboration between scientists, public institutions, and industry.
Professional nursing values: A concept analysis.
Schmidt, Bonnie J; McArthur, Erin C
2018-01-01
The aim of this concept analysis is to clarify the meaning of professional nursing values. In a time of increasing ethical dilemmas, it is essential that nurses internalize professional values to develop and maintain a professional identity. However, nursing organizations and researchers provide different conceptions of professional nursing values, leading to a lack of clarity as to the meaning and attributes of this construct. Walker and Avant's (2011) method was used to guide an analysis of this concept. Resources published from 1973 to 2016 were identified via electronic databases and hand-searching of reference lists. A review of the literature was completed and the data were analyzed to identify uses of the concept; the defining attributes of the concept; borderline, related, contrary, and illegitimate examples; antecedents and consequences; and empirical referents. Professional nursing values were defined as important professional nursing principles of human dignity, integrity, altruism, and justice that serve as a framework for standards, professional practice, and evaluation. Further research is needed in the development and testing of professional nursing values theory, and the reassessment of values instruments. Core professional values that are articulated may help unify the profession and demonstrate the value of nursing to the public. © 2017 Wiley Periodicals, Inc.
GSD-1G and MPI-DING Reference Glasses for In Situ and Bulk Isotopic Determination
Jochum, K.P.; Wilson, S.A.; Abouchami, W.; Amini, M.; Chmeleff, J.; Eisenhauer, A.; Hegner, E.; Iaccheri, L.M.; Kieffer, B.; Krause, J.; McDonough, W.F.; Mertz-Kraus, R.; Raczek, I.; Rudnick, R.L.; Scholz, Donna K.; Steinhoefel, G.; Stoll, B.; Stracke, A.; Tonarini, S.; Weis, D.; Weis, U.; Woodhead, J.D.
2011-01-01
This paper contains the results of an extensive isotopic study of United States Geological Survey GSD-1G and MPI-DING reference glasses. Thirteen different laboratories were involved using high-precision bulk (TIMS, MC-ICP-MS) and microanalytical (LA-MC-ICP-MS, LA-ICP-MS) techniques. Detailed studies were performed to demonstrate the large-scale and small-scale homogeneity of the reference glasses. Together with previously published isotopic data from ten other laboratories, preliminary reference and information values as well as their uncertainties at the 95% confidence level were determined for H, O, Li, B, Si, Ca, Sr, Nd, Hf, Pb, Th and U isotopes using the recommendations of the International Association of Geoanalysts for certification of reference materials. Our results indicate that GSD-1G and the MPI-DING glasses are suitable reference materials for microanalytical and bulk analytical purposes. Ce document contient les r??sultats d'une importante ??tude isotopique des verres de r??f??rence USGS GSD-1G et MPI-DING. Treize laboratoires diff??rents ont particip?? au travers de techniques analytiques de haute pr??cision travaillant soit sur ??chantillon total (TIMS, MC-ICP-MS) soit par microanalyse ??in situ?? (LA-MC-ICP-MS, LA-ICP-MS). ?? 2010 The Authors. Geostandards and Geoanalytical Research ?? 2010 International Association of Geoanalysts.
Exposure limits for nanoparticles: report of an international workshop on nano reference values.
van Broekhuizen, Pieter; van Veelen, Wim; Streekstra, Willem-Henk; Schulte, Paul; Reijnders, Lucas
2012-07-01
This article summarizes the outcome of the discussions at the international workshop on nano reference values (NRVs), which was organized by the Dutch trade unions and employers' organizations and hosted by the Social Economic Council in The Hague in September 2011. It reflects the discussions of 80 international participants representing small- and medium-size enterprises (SMEs), large companies, trade unions, governmental authorities, research institutions, and non-governmental organizations (NGOs) from many European countries, USA, India, and Brazil. Issues that were discussed concerned the usefulness and acceptability of precaution-based NRVs as a substitute for health-based occupational exposure limits (OELs) and derived no-effect levels (DNELs) for manufactured nanoparticles (NPs). Topics concerned the metrics for measuring NPs, the combined exposure to manufactured nanomaterials (MNMs) and process-generated NPs, the use of the precautionary principle, the lack of information about the presence of nanomaterials, and the appropriateness of soft regulation for exposure control. The workshop concluded that the NRV, as an 8-h time-weighted average, is a comprehensible and useful instrument for risk management of professional use of MNMs with a dispersible character. The question remains whether NRVs, as advised for risk management by the Dutch employers' organization and trade unions, should be under soft regulation or that a more binding regulation is preferable.
Guillén, J; Beresford, N A; Baeza, A; Izquierdo, M; Wood, M D; Salas, A; Muñoz-Serrano, A; Corrales-Vázquez, J M; Muñoz-Muñoz, J G
2018-06-01
A system for the radiological protection of the environment (or wildlife) based on Reference Animals and Plants (RAPs) has been suggested by the International Commission on Radiological Protection (ICRP). To assess whole-body activity concentrations for RAPs and the resultant internal dose rates, transfer parameters are required. However, transfer values specifically for the taxonomic families defined for the RAPs are often sparse and furthermore can be extremely site dependent. There is also a considerable geographical bias within available transfer data, with few data for Mediterranean ecosystems. In the present work, stable element concentrations (I, Li, Be, B, Na, Mg, Al, P, S, K. Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Mo, Ag, Cd, Cs, Ba, Tl, Pb and U) in terrestrial RAPs, and the corresponding whole-body concentration ratios, CR wo , were determined in two different Mediterranean ecosystems: a Pinewood and a Dehesa (grassland with disperse tree cover). The RAPs considered in the Pinewood ecosystem were Pine Tree and Wild Grass; whereas in the Dehesa ecosystem those considered were Deer, Rat, Earthworm, Bee, Frog, Duck and Wild Grass. The CR wo values estimated from these data are compared to those reported in international compilations and databases. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako
2016-01-01
Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.
Rathish, Devarajan; Senavirathna, Indika; Jayasumana, Channa; Agampodi, Suneth
2018-06-21
Assessment of acetylcholinesterase-inhibitor insecticide (AChEII) toxicity depends on the measurement of red blood cell acetylcholinesterase (RBC-AChE) activity. Its interpretation requires baseline values which is lacking in scientific literature. We aim to find the measures of central tendency and variation for RBC-AChE activity among dwellers of Anuradhapura, where the use and abuse of AChEIIs were rampant for the last few decades. A descriptive cross-sectional study with a community-based sampling for 100 healthy non-farmers (male:female = 1:1) was done using pre-determined selection criteria. Duplicate measurements of RBC-AChE activity were performed according to the modified Ellman procedure. Pearson's correlation and regression analysis were sort for RBC-AChE activity against its possible determinants. RBC-AChE activity had a mean of 449.8 (SD 74.2) mU/μM Hb with a statistical power of 0.847. It was similar to values of "healthy controls" from previous Sri Lankan toxicological studies but was low against international reference value [586.1 (SD 65.1) mU/μM Hb]. None of the possible determinants showed a significant strength of relationship with RBC-AChE activity. The baseline RBC-AChE activity among people of Anuradhapura is low in comparison with international reference values. This arises a need to find a causative mechanism.
Qi, Haiping; Coplen, Tyler B.; Geilmann, Heike; Brand, Willi A.; Böhlke, J.K.
2003-01-01
Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13C and 15N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a δ13C value of −26.24‰ relative to VPDB and a δ15N value of −4.52‰ relative to N2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13C and 15N. USGS41 has a δ13C value of +37.76‰ and a δ15N value of +47.57‰. The δ13C and δ15N values of both materials were measured against the international reference materials NBS 19 calcium carbonate (δ13C = +1.95‰), L-SVEC lithium carbonate (δ13C = −46.48‰), IAEA-N-1 ammonium sulfate (δ15N = 0.43‰), and USGS32 potassium nitrate (δ15N = 180‰) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ13C is better than 0.13‰, and that of δ15N is better than 0.13‰ in 100-μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ13C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off-line blank corrections probably have not been quantified satisfactorily.
Glycaemic index and glycaemic load values of a selection of popular foods consumed in Hong Kong.
Lok, Kris Y; Chan, Ruth; Chan, Dicken; Li, Liz; Leung, Grace; Woo, Jean; Lightowler, Helen J; Henry, C Jeya K
2010-02-01
The objective of the present paper is to provide glycaemic index (GI) and glycaemic load (GL) values for a variety of foods that are commonly consumed in Hong Kong and expand on the international GI table of Chinese foods. Fasted healthy subjects were given 50 g of available carbohydrate servings of a glucose reference, which was tested twice, and test foods of various brands of noodles (n 5), instant cereals (n 3) and breads (n 2), which were tested once, on separate occasions. For each test food, tests were repeated in ten healthy subjects. Capillary blood glucose was measured via finger-prick samples in fasting subjects ( - 5, 0 min) and at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI of each test food was calculated geometrically by expressing the incremental area under the blood glucose response curve (IAUC) of each test food as a percentage of each subject's average IAUC for the reference food. GL was calculated as the product of the test food's GI and the amount of available carbohydrate in a reference serving size. The majority of GI values of foods tested were medium (a GI value of 56-69) to high (a GI value of 70 or more) and compared well with previously published values. More importantly, our dataset provides GI values of ten foods previously untested and presents values for foods commonly consumed in Hong Kong.
Occupational health standards. An international comparison.
Holmberg, B; Winell, M
1977-03-01
The background for establishing standards for toxic agents is reviewed, and the standards of 14 different countries, including Sweden, are compared with special reference to criteria and organizational aspects. The differences among countries in the numerical limit values for toxic substances are largely due to differences in definitions, biomedical criteria, technical feasibility and sociopolitical judgements.
Update of the Dutch manual for costing studies in health care
Kanters, Tim A.; Bouwmans, Clazien A. M.; van der Linden, Naomi; Tan, Siok Swan; Hakkaart-van Roijen, Leona
2017-01-01
Objectives Dutch health economic guidelines include a costing manual, which describes preferred research methodology for costing studies and reference prices to ensure high quality studies and comparability between study outcomes. This paper describes the most important revisions of the costing manual compared to the previous version. Methods An online survey was sent out to potential users of the costing manual to identify topics for improvement. The costing manual was aligned with contemporary health economic guidelines. All methodology sections and parameter values needed for costing studies, particularly reference prices, were updated. An expert panel of health economists was consulted several times during the review process. The revised manual was reviewed by two members of the expert panel and by reviewers of the Dutch Health Care Institute. Results The majority of survey respondents was satisfied with content and usability of the existing costing manual. Respondents recommended updating reference prices and adding some particular commonly needed reference prices. Costs categories were adjusted to the international standard: 1) costs within the health care sector; 2) patient and family costs; and 3) costs in other sectors. Reference prices were updated to reflect 2014 values. The methodology chapter was rewritten to match the requirements of the costing manual and preferences of the users. Reference prices for nursing days of specific wards, for diagnostic procedures and nurse practitioners were added. Conclusions The usability of the costing manual was increased and parameter values were updated. The costing manual became integrated in the new health economic guidelines. PMID:29121647
Update of the Dutch manual for costing studies in health care.
Kanters, Tim A; Bouwmans, Clazien A M; van der Linden, Naomi; Tan, Siok Swan; Hakkaart-van Roijen, Leona
2017-01-01
Dutch health economic guidelines include a costing manual, which describes preferred research methodology for costing studies and reference prices to ensure high quality studies and comparability between study outcomes. This paper describes the most important revisions of the costing manual compared to the previous version. An online survey was sent out to potential users of the costing manual to identify topics for improvement. The costing manual was aligned with contemporary health economic guidelines. All methodology sections and parameter values needed for costing studies, particularly reference prices, were updated. An expert panel of health economists was consulted several times during the review process. The revised manual was reviewed by two members of the expert panel and by reviewers of the Dutch Health Care Institute. The majority of survey respondents was satisfied with content and usability of the existing costing manual. Respondents recommended updating reference prices and adding some particular commonly needed reference prices. Costs categories were adjusted to the international standard: 1) costs within the health care sector; 2) patient and family costs; and 3) costs in other sectors. Reference prices were updated to reflect 2014 values. The methodology chapter was rewritten to match the requirements of the costing manual and preferences of the users. Reference prices for nursing days of specific wards, for diagnostic procedures and nurse practitioners were added. The usability of the costing manual was increased and parameter values were updated. The costing manual became integrated in the new health economic guidelines.
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae
2014-07-01
In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.
Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae
2014-07-21
In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.
39 CFR 20.1 - International Mail Manual; incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
... reference. 20.1 Section 20.1 Postal Service UNITED STATES POSTAL SERVICE INTERNATIONAL MAIL INTERNATIONAL POSTAL SERVICE § 20.1 International Mail Manual; incorporation by reference. (a) Section 552(a) of Title... provided in this part, the U.S. Postal Service hereby incorporates by reference its International Mail...
NASA Astrophysics Data System (ADS)
Villoing, Daphnée; Marcatili, Sara; Garcia, Marie-Paule; Bardiès, Manuel
2017-03-01
The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model proposed by the International Commission on Radiological Protection in ICRP report 110. Monoenergetic photons and electrons (from 50 keV to 2 MeV) and four isotopes currently used in nuclear medicine (fluorine-18, lutetium-177, iodine-131 and yttrium-90) were investigated. Absorbed fractions, specific absorbed fractions and S-values were generated with GATE and MCNPX for 12 regions of interest in the ICRP 110 female computational model, thereby leading to 144 source/target pair configurations. Relative differences between GATE and MCNPX obtained in specific configurations (self-irradiation or cross-irradiation) are presented. Relative differences in absorbed fractions, specific absorbed fractions or S-values are below 10%, and in most cases less than 5%. Dosimetric results generated with GATE for the 12 volumes of interest are available as supplemental data. GATE can be safely used for radiopharmaceutical dosimetry at the clinical scale. This makes GATE a viable option for Monte Carlo modelling of both imaging and absorbed dose in nuclear medicine.
Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.
2009-01-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.
Optimized angiotensin-converting enzyme activity assay for the accurate diagnosis of sarcoidosis.
Csongrádi, Alexandra; Enyedi, Attila; Takács, István; Végh, Tamás; Mányiné, Ivetta S; Pólik, Zsófia; Altorjay, István Tibor; Balla, József; Balla, György; Édes, István; Kappelmayer, János; Tóth, Attila; Papp, Zoltán; Fagyas, Miklós
2018-06-27
Serum angiotensin-converting enzyme (ACE) activity determination can aid the early diagnosis of sarcoidosis. We aimed to optimize a fluorescent kinetic assay for ACE activity by screening the confounding effects of endogenous ACE inhibitors and interfering factors. Genotype-dependent and genotype-independent reference values of ACE activity were established, and their diagnostic accuracies were validated in a clinical study. Internally quenched fluorescent substrate, Abz-FRK(Dnp)P-OH was used for ACE-activity measurements. A total of 201 healthy individuals and 59 presumably sarcoidotic patients were enrolled into this study. ACE activity and insertion/deletion (I/D) genotype of the ACE gene were determined. Here we report that serum samples should be diluted at least 35-fold to eliminate the endogenous inhibitor effect of albumin. No significant interferences were detected: up to a triglyceride concentration of 16 mM, a hemoglobin concentration of 0.71 g/L and a bilirubin concentration of 150 μM. Genotype-dependent reference intervals were considered as 3.76-11.25 U/L, 5.22-11.59 U/L, 7.19-14.84 U/L for II, ID and DD genotypes, respectively. I/D genotype-independent reference interval was established as 4.85-13.79 U/L. An ACE activity value was considered positive for sarcoidosis when it exceeded the upper limit of the reference interval. The optimized assay with genotype-dependent reference ranges resulted in 42.5% sensitivity, 100% specificity, 100% positive predictive value and 32.4% negative predictive value in the clinical study, whereas the genotype-independent reference range proved to have inferior diagnostic efficiency. An optimized fluorescent kinetic assay of serum ACE activity combined with ACE I/D genotype determination is an alternative to invasive biopsy for confirming the diagnosis of sarcoidosis in a significant percentage of patients.
Test of simple fluid theories for the Lennard-Jones system
NASA Astrophysics Data System (ADS)
Malijevský, A.; Labik, S.
1988-03-01
A test is made of a new version of the reference-hypernetted chain approximation (RHNC) with minimized free energy proposed by Lado, Foiles and Ashcroft. An accurate relationship is used for the bridge function of the reference hard spheres. The calculated values of the compressibility factor and the internal energy are compared with simulation data, with results of the exponential approximation of Andersen et al., and with results of the Madden-Fitts approximation. The RHNC provides the most reliable results over wide ranges of reduced temperatures and densities.
Charfi, Iness; Nagi, Karim; Mnie-Filali, Ouissame; Thibault, Dominic; Balboni, Gianfranco; Schiller, Peter W.; Trudeau, Louis-Eric
2014-01-01
Signaling bias refers to G protein-coupled receptor ligand ability to preferentially activate one type of signal over another. Bias to evoke signaling as opposed to sequestration has been proposed as a predictor of opioid ligand potential for generating tolerance. Here we measured whether delta opioid receptor agonists preferentially inhibited cyclase activity over internalization in HEK cells. Efficacy (τ) and affinity (KA) values were estimated from functional data and bias was calculated from efficiency coefficients (log τ/KA). This approach better represented the data as compared to alternative methods that estimate bias exclusively from τ values. Log (τ/KA) coefficients indicated that SNC-80 and UFP-512 promoted cyclase inhibition more efficiently than DOR internalization as compared to DPDPE (bias factor for SNC-80: 50 and for UFP-512: 132). Molecular determinants of internalization were different in HEK293 cells and neurons with βarrs contributing to internalization in both cell types, while PKC and GRK2 activities were only involved in neurons. Rank orders of ligand ability to engage different internalization mechanisms in neurons were compared to rank order of Emax values for cyclase assays in HEK cells. Comparison revealed a significant reversal in rank order for cyclase Emax values and βarr-dependent internalization in neurons, indicating that these responses were ligand-specific. Despite this evidence, and because kinases involved in internalization were not the same across cellular backgrounds, it is not possible to assert if the magnitude and nature of bias revealed by rank orders of maximal responses is the same as the one measured in HEK cells. PMID:24022593
Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz
2017-01-01
High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.
2017-11-01
This proceedings report presents the outcomes from an international workshop supported by the European Society of Human Reproduction and Embryology (ESHRE) and Alpha Scientists in Reproductive Medicine, designed to establish consensus on definitions and recommended values for Indicators for the assisted reproductive technology (ART) laboratory. Minimum performance-level values ('competency') and aspirational ('benchmark') values were recommended for a total of 19 Indicators, including 12 Key Performance Indicators (KPIs), five Performance Indicators (PIs), and two Reference Indicators (RIs). Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Qureshi, Waqas T.; Leigh, J. Adam; Swett, Katrina; Ajay, Dharod; Allison, Matthew A.; Cai, Jianwen; Gonzalez, Franklyn; Hurwitz, Barry E.; Shah, Sanjiv J.; Desai, Ankit A.; Spevack, Daniel M.; Rodriguez, Carlos J.
2015-01-01
Background Reference limits for echocardiographic quantification of cardiac chambers in Hispanics are not well studied. Methods and Results We examined the reference values of left atrium (LA) and ventricle (LV) structure in a large ethnically diverse Hispanic cohort. Two-dimensional transthoracic echocardiography was performed in 1,818 participants of the Echocardiographic Study of Latinos (ECHO-SOL). Individuals with body mass index ≥30kg/m2, hypertension, diabetes mellitus, coronary artery disease and atrial fibrillation were excluded leaving 525 participants defined as healthy reference-cohort. We estimated 95th weighted percentiles of LV end systolic volume, LV end diastolic volume, relative wall and septal thickness, LV mass and left atrial volume. We then used upper reference limits of the 2005 and 2015 American Society of Echocardiography (ASE) and 95th percentile of reference cohort to classify the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) target population into abnormal and normal. Reference limits were also calculated for each of 6 Hispanic origins. Using ASE 2015 defined reference values we categorized 7%, 21%, 57% and 17% of males and 18%, 29%, 60% and 26% of females as having abnormal LV mass index, relative, septal and posterior wall thickness, respectively. Conversely, 10%, and 11% of males and 4% and 2% of females were classified as having abnormal end-diastolic volume and internal diameter by ASE 2015 cut-offs, respectively. Similar differences were found when we used 2005 ASE cut offs. Several differences were noted in distribution of cardiac structure and volumes among various Hispanic/Latino origins. Cubans had highest values of echocardiographic measures and Central Americans had the lowest. Conclusions This is the first large study that provides normal reference values for cardiac structure. It further demonstrates that a considerable segment of Hispanic/Latinos residing in US may be classified as having abnormal measures of cardiac chambers when 2015 and 2005 ASE reference cut-offs are used. PMID:26712159
Júlíusson, Pétur B; Roelants, Mathieu; Benestad, Beate; Lekhal, Samira; Danielsen, Yngvild; Hjelmesaeth, Jøran; Hertel, Jens K
2018-02-01
We analysed the distribution of the body mass index standard deviation scores (BMI-SDS) in children and adolescents seeking treatment for severe obesity, according to the International Obesity Task Force (IOTF), World Health Organization (WHO) and the national Norwegian Bergen Growth Study (BGS) BMI reference charts and the percentage above the International Obesity Task Force 25 cut-off (IOTF-25). This was a cross-sectional study of 396 children aged four to 17 years, who attended a tertiary care obesity centre in Norway from 2009 to 2015. Their BMI was converted to SDS using the three growth references and expressed as the percentage above IOTF-25. The percentage of body fat was assessed by bioelectrical impedance analysis. Regardless of which BMI reference chart was used, the BMI-SDS was significantly different between the age groups, with a wider range of higher values up to 10 years of age and a more narrow range of lower values thereafter. The distributions of the percentage above IOTF-25 and percentage of body fat were more consistent across age groups. Our findings suggest that it may be more appropriate to use the percentage above a particular BMI cut-off, such as the percentage above IOTF-25, than the IOTF, WHO and BGS BMI-SDS in paediatric patients with severe obesity. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Findlay, L; Desai, T; Heath, A; Poole, S; Crivellone, M; Hauck, W; Ambrose, M; Morris, T; Daas, A; Rautmann, G; Buchheit, K H; Spieser, J M; Terao, E
2015-01-01
An international collaborative study was organised jointly by the World Health Organization (WHO)/National Institute for Biological Standards and Control (NIBSC), the United States Pharmacopeia (USP) and the European Directorate for the Quality of Medicines & HealthCare (EDQM/Council of Europe) for the establishment of harmonised replacement endotoxin standards for these 3 organisations. Thirty-five laboratories worldwide, including Official Medicines Control Laboratories (OMCLs) and manufacturers enrolled in the study. Three candidate preparations (10/178, 10/190 and 10/196) were produced with the same material and same formulation as the current reference standards with the objective of generating a new (3(rd)) International Standard (IS) with the same potency (10 000 IU/vial) as the current (2(nd)) IS, as well as new European Pharmacopoeia (Ph. Eur.). and USP standards. The suitability of the candidate preparations to act as the reference standard in assays for endotoxin performed according to compendial methods was evaluated. Their potency was calibrated against the WHO 2(nd) IS for Endotoxin (94/580). Gelation and photometric methods produced similar results for each of the candidate preparations. The overall potency estimates for the 3 batches were comparable. Given the intrinsic assay precision, the observed differences between the batches may be considered unimportant for the intended use of these materials. Overall, these results were in line with those generated for the establishment of the current preparations of reference standards. Accelerated degradation testing of vials stored at elevated temperatures supported the long-term stability of the 3 candidate preparations. It was agreed between the 3 organisations that batch 10/178 be shared between WHO and EDQM and that batches 10/190 and 10/196 be allocated to USP, with a common assigned value of 10 000 IU/vial. This value maintains the continuity of the global harmonisation of reference materials and unitage for the testing of endotoxins in parenteral pharmaceutical products. Based on the results of the collaborative study, batch 10/178 was established by the European Pharmacopoeia Commission as the Ph. Eur. Endotoxin Biological Reference Preparation (BRP) batch 5. The same batch was also established by the Expert Committee on Biological Standardisation (ECBS) of WHO as the WHO 3(rd) IS for Endotoxin. Batch 10/190 was adopted as the USP Endotoxin Reference Standard, lot H0K354 and vials from this same batch (10/190) will serve as the United States Food and Drug Administration (USFDA) Endotoxin Standard, EC-7.
Development and certification of the new SRM 695 trace elements in multi-nutrient fertilizer
MacKey, E.A.; Cronise, M.P.; Fales, C.N.; Greenberg, R.R.; Leigh, S.D.; Long, S.E.; Marlow, A.F.; Murphy, K.E.; Oflaz, R.; Sieber, J.R.; Rearick, M.S.; Wood, L.J.; Yu, L.L.; Wilson, S.A.; Briggs, P.H.; Brown, Z.A.; Budahn, J.; Kane, P.F.; Hall, W.L.
2007-01-01
During the past seven years, several states within the US have enacted regulations that limit the amounts of selected non-nutritive elements in fertilizers. Internationally, several countries, including Japan, China, and Australia, and the European Union also limit the amount of selected elements in fertilizers. The elements of interest include As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Se, and Zn. Fertilizer manufacturers and state regulatory authorities, faced with meeting and verifying these limits, need to develop analytical methods for determination of the elements of concern and to validate results obtained using these methods. Until now, there were no certified reference materials available with certified mass fraction values for all elements of interest in a blended, multi-nutrient fertilizer matrix. A new standard reference material (SRM) 695 trace elements in multi-nutrient fertilizer, has been developed to help meet these needs. SRM 695 has recently been issued with certified mass fraction values for seventeen elements, reference values for an additional five elements, and information values for two elements. The certificate of analysis includes an addendum listing percentage recovery for eight of these elements, determined using an acid-extraction inductively-coupled plasma optical-emission spectrometry (ICP-OES) method recently developed and tested by members of the Association of American Plant Food Control Officials. ?? Springer-Verlag 2007.
Database of natural matrix reference materials (NMRM) for organic constituents.
Iyengar, G V; Bleise, A R
2001-06-01
The International Atomic Energy Agency maintains a database of internationally available certified reference materials (CRM) of natural matrices. This database is periodically updated, and presently documents nearly 25,000 measurands in 1,700 materials. The organic constituents are classified in five major groups of analytes aliphatic and aromatic hydrocarbons (A), chlorinated hydrocarbons (B), pesticides (C), organometallic compounds (D) and other organic constituents (nutrients, etc.) (E). The matrices include natural materials such as body fluids, food products, soils, and sediments, terrestrial (e.g. plants), and anthropogenic products (e.g. dust, fly ash). These five organic groups of analytes encompass more than 2000 measurands for 420 different analytes in 230 materials. Of these measurands, 1,682 (68%) are certified, and 768 (32%) are provided as informational values. Within each major group of analytes, measurands reported as informational values accounted for: A (35%); B (35%); C (26%); D (10%), and E (22%). The high proportion of informational values (i.e. non-certified values) for A, B, and C, compares well with a similar but undesirable situation faced in the nineteen-seventies in the inorganic area when simultaneous multielement techniques became available. In the case of D and E, it appears that mostly targeted analytes are measured, leading to a cohesive certification profile. Although the IAEA database is not equally comprehensive for all groups of analytes cited above, it can still serve as an useful indicator of the status of organic constituents in RMs.
Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?
Ceriotti, Ferruccio
2018-03-30
Measurement uncertainty (MU) is a "non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used". In the clinical laboratory the most convenient way to calculate MU is the "top down" approach based on the use of Internal Quality Control data. As indicated in the definition, MU depends on the information used for its calculation and so different estimates of MU can be obtained. The most problematic aspect is how to deal with bias. In fact bias is difficult to detect and quantify and it should be corrected including only the uncertainty derived from this correction. Several approaches to calculate MU starting from Internal Quality Control data are presented. The minimum requirement is to use only the intermediate precision data, provided to include 6 months of results obtained with a commutable quality control material at a concentration close to the clinical decision limit. This approach is the minimal requirement and it is convenient for all those measurands that are especially used for monitoring or where a reference measurement system does not exist and so a reference for calculating the bias is lacking. Other formulas including the uncertainty of the value of the calibrator, including the bias from a commutable certified reference material or from a material specifically prepared for trueness verification, including the bias derived from External Quality Assessment schemes or from historical mean of the laboratory are presented and commented. MU is an important parameter, but a single, agreed upon way to calculate it in a clinical laboratory is not yet available. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Verma, Mascha; Khadapkar, Rashmi; Sahu, Priyadarshi Soumyaranjan; Das, Bibhu Ranjan
2006-09-01
An increase in the communication within the healthcare services, both nationally and internationally, has strengthened the need for harmonization of measurements and reference intervals in laboratory medicine. In the present report, the calculated reference interval for serum creatinine (sCr) levels of healthy normal individuals (n=1121) in different sex and age groups are compared with the established interval. The calculated reference interval for sCr level was 0.4-1.3 mg/dL and 0.6 to 1.3 mg/dL in the age groups of 21-40 and 41-60 years respectively. The difference between the mean sCr values in total males and total females (age range 21-60 years) was statistically significant (p<0.0001); When male and female subjects were analyzed age-group wise, the data showed a significant difference in mean sCr values (p<0.0001) in three age groups (21-30, 31-40 and 41-50 years) however, in older age group (51-60 years), the difference was non-significant (p=0.07). The reference ranges were 0.7-1.3 and 0.4-1.0 mg/dL for males and females respectively where the lower limit was 0.1-0.2 units less than that of standard limits. An increase in the mean value of sCr was observed particularly in females with an increase in age. Hence it is of interest to validate an age specific reference ranges for sCr in our population.
Kleinnijenhuis, Michiel; Mollink, Jeroen; Lam, Wilfred W; Kinchesh, Paul; Khrapitchev, Alexandre A; Smart, Sean C; Jbabdi, Saad; Miller, Karla L
2018-02-01
To demonstrate how reference data affect the quantification of the apparent diffusion coefficient (ADC) in long diffusion time measurements with diffusion-weighted stimulated echo acquisition mode (DW-STEAM) measurements, and to present a modification to avoid contribution from crusher gradients in DW-STEAM. For DW-STEAM, reference measurements at long diffusion times have significant b 0 value, because b = 0 cannot be achieved in practice as a result of the need for signal spoiling. Two strategies for acquiring reference data over a range of diffusion times were considered: constant diffusion weighting (fixed-b 0 ) and constant gradient area (fixed-q 0 ). Fixed-b 0 and fixed-q 0 were compared using signal calculations for systems with one and two diffusion coefficients, and experimentally using data from postmortem human corpus callosum samples. Calculations of biexponential diffusion decay show that the ADC is underestimated for reference images with b > 0, which can induce an apparent time-dependence for fixed-q 0 . Restricted systems were also found to be affected. Experimentally, the exaggeration of the diffusion time-dependent effect under fixed-q 0 versus fixed-b 0 was in a range predicted theoretically, accounting for 62% (longitudinal) and 35% (radial) of the time dependence observed in white matter. Variation in the b-value of reference measurements in DW-STEAM can induce artificial diffusion time dependence in ADC, even in the absence of restriction. Magn Reson Med 79:952-959, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.
Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T
2017-12-01
The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.
Flammability of gas mixtures. Part 1: fire potential.
Schröder, Volkmar; Molnarne, Maria
2005-05-20
International and European dangerous substances and dangerous goods regulations refer to the standard ISO 10156 (1996). This standard includes a test method and a calculation procedure for the determination of the flammability of gases and gas mixtures in air. The substance indices for the calculation, the so called "Tci values", which characterise the fire potential, are provided as well. These ISO Tci values are derived from explosion diagrams of older literature sources which do not take into account the test method and the test apparatus. However, since the explosion limits are influenced by apparatus parameters, the Tci values and lower explosion limits, given by the ISO tables, are inconsistent with those measured according to the test method of the same standard. In consequence, applying the ISO Tci values can result in wrong classifications. In this paper internationally accepted explosion limit test methods were evaluated and Tci values were derived from explosion diagrams. Therefore, an "open vessel" method with flame propagation criterion was favoured. These values were compared with the Tci values listed in ISO 10156. In most cases, significant deviations were found. A detailed study about the influence of inert gases on flammability is the objective of Part 2.
Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok
2014-02-01
The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment.
Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok
2014-01-01
The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment. PMID:24678503
Energy performance indicators of wastewater treatment: a field study with 17 Portuguese plants.
Silva, Catarina; Rosa, Maria João
2015-01-01
The energy costs usually represent the second largest part of the running costs of a wastewater treatment plant (WWTP). It is therefore crucial to increase the energy efficiency of these infrastructures and to implement energy management systems, where quantitative performance metrics, such as performance indicators (PIs), play a key role. This paper presents energy PIs which cover the unit energy consumption, production, net use from external sources and costs, and the results used to validate them and derive their reference values. The results of a field study with 17 Portuguese WWTPs (5-year period) were consistent with the results obtained through an international literature survey on the two key parcels of the energy balance--consumption and production. The unit energy consumption showed an overall inverse relation with the volume treated, and the reference values reflect this relation for trickling filters and for activated sludge systems (conventional, with coagulation/filtration (C/F) and with nitrification and C/F). The reference values of electrical energy production were derived from the methane generation potential (converted to electrical energy) and literature data, whereas those of energy net use were obtained by the difference between the energy consumption and production.
Mulloy, B; Heath, A; Behr-Gross, M-E
2007-12-01
An international collaborative study involving fourteen laboratories has taken place, organised by the European Directorate for the Quality of Medicines & HealthCare (EDQM) with National Institute for Biological Standards & Control (NIBSC) (in its capacity as a World Health Organisation (WHO) Laboratory for Biological Standardisation) to provide supporting data for the establishment of replacement batches of Heparin Low-Molecular-Mass (LMM) for Calibration Chemical Reference Substance (CRS), and of the International Reference Reagent (IRR) Low Molecular Weight Heparin for Molecular Weight Calibration. A batch of low-molecular-mass heparin was donated to the organisers and candidate preparations of freeze-dried heparin were produced at NIBSC and EDQM. The establishment study was organised in two phases: a prequalification (phase 1, performed in 3 laboratories in 2005) followed by an international collaborative study (phase 2). In phase 2, started in March 2006, molecular mass parameters were determined for seven different LMM heparin samples using the current CRS batch and two batches of candidate replacement material with a defined number average relative molecular mass (Mn) of 3,700, determined in phase 1. The values calculated using the candidates as standard were systematically different from values calculated using the current batch with its assigned number-average molecular mass (Mna) of 3,700. Using raw data supplied by participants, molecular mass parameters were recalculated using the candidates as standard with values for Mna of 3,800 and 3,900. Values for these parameters agreed more closely with those calculated using the current batch supporting the fact that the candidates, though similar to batch 1 in view of the production processes used, differ slightly in terms of molecular mass distribution. Therefore establishment of the candidates was recommended with an assigned Mna value of 3,800 that is both consistent with phase 1 results and guarantees continuity with the current CRS batch. In phase 2, participants also determined molecular weight parameters for the seven different LMM heparin samples using both the 1st IRR (90/686) and its Broad Standard Table and the candidate World Health Organization (WHO) 2nd International Standard (05/112) (2nd IS) using a Broad Standard Table established in phase 1. Mean molecular weights calculated using 2nd IS were slightly higher than with 1st IRR, and participants in the study indicated that this systematic difference precluded establishment of 2nd IS with the table supplied. A replacement Broad Standard Table has been devised on the basis of the central recalculations of raw data supplied by participants; this table gives improved agreement between values derived using the 1st IRR and the candidate 2nd IS. On the basis of this study a recommendation was made for the establishment of 2nd IS and its proposed Broad Standard Table as a replacement for the 1st International Reference Reagent Low Molecular Weight Heparin for Molecular Weight Calibration. Unlike the 1st IRR however, the candidate material 2nd IS is not suitable for use with the method of Nielsen. The candidate materials were established as heparin low-molecular-mass for calibration batches 2 and 3 by the Ph. Eur. Commission in March 2007 and as 2nd IS low-molecular-weight heparin for molecular weight calibration (05/112) by the Expert Committee on Biological Standardization in November 2007.
CODATA recommended values of the fundamental constants
NASA Astrophysics Data System (ADS)
Mohr, Peter J.; Taylor, Barry N.
2000-11-01
A review is given of the latest Committee on Data for Science and Technology (CODATA) adjustment of the values of the fundamental constants. The new set of constants, referred to as the 1998 values, replaces the values recommended for international use by CODATA in 1986. The values of the constants, and particularly the Rydberg constant, are of relevance to the calculation of precise atomic spectra. The standard uncertainty (estimated standard deviation) of the new recommended value of the Rydberg constant, which is based on precision frequency metrology and a detailed analysis of the theory, is approximately 1/160 times the uncertainty of the 1986 value. The new set of recommended values as well as a searchable bibliographic database that gives citations to the relevant literature is available on the World Wide Web at physics.nist.gov/constants and physics.nist.gov/constantsbib, respectively. .
Ionospheric foF2 at EIA region: comparison between observations and IRI model
NASA Astrophysics Data System (ADS)
Chuo, Y. J.; Lee, C. C.
We have used data from an equatorial ionization anomaly area station in the western Pacific region to study the monthly variability of foF2 Diurnal seasonal and solar activity effects were investigated The data established by this study are proposed as valid input values for the development of URSI and CCIR options for the International Reference Ionosphere
Report of the International Ice Patrol Service in the North Atlantic Ocean. Season of 1979.
1979-01-01
used is ( Scobie and Schultz, 1976) and it is basically these the sum of a mean value and a wind driven compo- updated currents which were used during...direction REFERENCES and U (east-west) and V (north-south) components Scobie , R. W. and R. H. Schultz (1976). Oceanography of on a printout and plots
NASA Astrophysics Data System (ADS)
Tarao, H.; Kuisti, H.; Korpinen, L.; Hayashi, N.; Isaka, K.
2012-05-01
Contact currents flow through the human body when a conducting object with different potential is touched. There are limited reports on numerical dosimetry for contact current exposure compared with electromagnetic field exposures. In this study, using an anatomical human adult male model, we performed numerical calculation of internal electric fields resulting from 60 Hz contact current flowing from the left hand to the left foot as a basis case. Next, we performed a variety of similar calculations with varying tissue conductivity and contact area, and compared the results with the basis case. We found that very low conductivity of skin and a small electrode size enhanced the internal fields in the muscle, subcutaneous fat and skin close to the contact region. The 99th percentile value of the fields in a particular tissue type did not reliably account for these fields near the electrode. In the arm and leg, the internal fields for the muscle anisotropy were identical to those in the isotropy case using a conductivity value longitudinal to the muscle fibre. Furthermore, the internal fields in the tissues abreast of the joints such as the wrist and the elbow, including low conductivity tissues, as well as the electrode contact region, exceeded the ICNIRP basic restriction for the general public with contact current as the reference level value.
2003-01-01
Data are not readily available on the accuracy of one of the most commonly used home blood glucose meters, the One Touch Ultra (LifeScan, Milpitas, California). The purpose of this report is to provide information on the accuracy of this home glucose meter in children with type 1 diabetes. During a 24-h clinical research center stay, the accuracy of the Ultra meter was assessed in 91 children, 3-17 years old, with type 1 diabetes by comparing the Ultra glucose values with concurrent reference serum glucose values measured in a central laboratory. The Pearson correlation between the 2,068 paired Ultra and reference values was 0.97, with the median relative absolute difference being 6%. Ninety-four percent of all Ultra values (96% of venous and 84% of capillary samples) met the proposed International Organisation for Standardisation (ISO) standard for instruments used for self-monitoring of glucose when compared with venous reference values. Ninety-nine percent of values were in zones A + B of the Modified Error Grid. A high degree of accuracy was seen across the full range of glucose values. For 353 data points during an insulin-induced hypoglycemia test, the Ultra meter was found to have accuracy that was comparable to concurrently used benchmark instruments (Beckman, YSI, or i-STAT); 95% and 96% of readings from the Ultra meter and the benchmark instruments met the proposed ISO criteria, respectively. These results confirm that the One Touch Ultra meter provides accurate glucose measurements for both hypoglycemia and hyperglycemia in children with type 1 diabetes.
NASA Astrophysics Data System (ADS)
Behrens, R.
2015-03-01
The International Organization for Standardization (ISO) requires in its standard ISO 6980 that beta reference radiation fields for radiation protection be calibrated in terms of absorbed dose to tissue at a depth of 0.07 mm in a slab phantom (30 cm x 30 cm x 15 cm). However, many beta dosemeters are ring dosemeters and are, therefore, irradiated on a rod phantom (1.9 cm in diameter and 30 cm long), or they are eye dosemeters possibly irradiated on a cylinder phantom (20 cm in diameter and 20 cm high), or area dosemeters irradiated free in air with the conventional quantity value (true value) being defined in a sphere (30 cm in diameter, made of ICRU tissue (International Commission on Radiation Units and Measurements)). Therefore, the correction factors for the conventional quantity value in the rod, the cylinder, and the sphere instead of the slab (all made of ICRU tissue) were calculated for the radiation fields of 147Pm, 85Kr, 90Sr/90Y, and, 106Ru/106Rh sources of the beta secondary standard BSS 2 developed at PTB. All correction factors were calculated for 0° up to 75° (in steps of 15°) radiation incidence. The results are ready for implementation in ISO 6980-3 and have recently been (partly) implemented in the software of the BSS 2.
Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P
2014-01-01
The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger age and drop moderately as age increases. We have presented NHANES reference curves applicable to DXA whole-body scans acquired on GE Healthcare Lunar systems by age, sex and ethnicity. Users of GE Healthcare GE-Lunar DXA systems can now benefit from the large body composition reference data set collected in the NHANES 1999-2004 study. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Reference values of left heart echocardiographic dimensions and mass in male peri-pubertal athletes.
Cavarretta, Elena; Maffessanti, Francesco; Sperandii, Fabio; Guerra, Emanuele; Quaranta, Federico; Nigro, Antonia; Minati, Monia; Rebecchi, Marco; Fossati, Chiara; Calò, Leonardo; Pigozzi, Fabio
2018-01-01
Background Several articles have proposed reference values in healthy paediatric subjects, but none of them has evaluated a large population of healthy trained adolescents. Design The study purpose was to establish normal echocardiographic measurements of left heart (aortic root, left atrium and left ventricular dimensions and mass) in relation to age, weight, height, body mass index, body surface area and training hours in this specific population. Methods We retrospectively evaluated 2151 consecutive, healthy, peri-pubertal athletes (100% male, mean age 12.4 ± 1.4 years, range 8-18) referred to a single centre for pre-participation screening. All participants were young soccer athletes who trained for a mean of 7.2 ± 1.1 h per week. Results Left ventricular internal diameters, wall thickness, left ventricular mass, aortic root and left atrium diameters were significantly correlated to age, body surface area, height and weight ( p < 0.01). Age, height, weight and body surface area were found associated with chamber size, while body mass index and training hours were not. Inclusion of both age and body size parameters in the statistical models resulted in improved overall explained variance for diameters and left ventricular mass. Conclusion Equations, mean values and percentile charts for the different age groups may be useful as reference data in efficiently assessing left ventricular parameters in young athletes.
Koprivica, Mladen; Slavkovic, Vladimir; Neskovic, Natasa; Neskovic, Aleksandar
2016-03-01
As a result of dense deployment of public mobile base stations, additional electromagnetic (EM) radiation occurs in the modern human environment. At the same time, public concern about the exposure to EM radiation emitted by such sources has increased. In order to determine the level of radio frequency radiation generated by base stations, extensive EM field strength measurements were carried out for 664 base station locations, from which 276 locations refer to the case of base stations with antenna system installed on buildings. Having in mind the large percentage (42 %) of locations with installations on buildings, as well as the inevitable presence of people in their vicinity, a detailed analysis of this location category was performed. Measurement results showed that the maximum recorded value of total electric field strength has exceeded International Commission on Non-Ionizing Radiation Protection general public exposure reference levels at 2.5 % of locations and Serbian national reference levels at 15.6 % of locations. It should be emphasised that the values exceeding the reference levels were observed only outdoor, while in indoor total electric field strength in no case exceeded the defined reference levels. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Defining Chlorophyll-a Reference Conditions in European Lakes
Alves, Maria Helena; Argillier, Christine; van den Berg, Marcel; Buzzi, Fabio; Hoehn, Eberhard; de Hoyos, Caridad; Karottki, Ivan; Laplace-Treyture, Christophe; Solheim, Anne Lyche; Ortiz-Casas, José; Ott, Ingmar; Phillips, Geoff; Pilke, Ansa; Pádua, João; Remec-Rekar, Spela; Riedmüller, Ursula; Schaumburg, Jochen; Serrano, Maria Luisa; Soszka, Hanna; Tierney, Deirdre; Urbanič, Gorazd; Wolfram, Georg
2010-01-01
The concept of “reference conditions” describes the benchmark against which current conditions are compared when assessing the status of water bodies. In this paper we focus on the establishment of reference conditions for European lakes according to a phytoplankton biomass indicator—the concentration of chlorophyll-a. A mostly spatial approach (selection of existing lakes with no or minor human impact) was used to set the reference conditions for chlorophyll-a values, supplemented by historical data, paleolimnological investigations and modelling. The work resulted in definition of reference conditions and the boundary between “high” and “good” status for 15 main lake types and five ecoregions of Europe: Alpine, Atlantic, Central/Baltic, Mediterranean, and Northern. Additionally, empirical models were developed for estimating site-specific reference chlorophyll-a concentrations from a set of potential predictor variables. The results were recently formulated into the EU legislation, marking the first attempt in international water policy to move from chemical quality standards to ecological quality targets. PMID:20401659
Recommendation for the review of biological reference intervals in medical laboratories.
Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel
2016-12-01
This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.
Standard reference water samples for rare earth element determinations
Verplanck, P.L.; Antweiler, Ronald C.; Nordstrom, D. Kirk; Taylor, Howard E.
2001-01-01
Standard reference water samples (SRWS) were collected from two mine sites, one near Ophir, CO, USA and the other near Redding, CA, USA. The samples were filtered, preserved, and analyzed for rare earth element (REE) concentrations (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) by inductively coupled plasma-mass spectrometry (ICP-MS). These two samples were acid mine waters with elevated concentrations of REEs (0.45-161 ??g/1). Seventeen international laboratories participated in a 'round-robin' chemical analysis program, which made it possible to evaluate the data by robust statistical procedures that are insensitive to outliers. The resulting most probable values are reported. Ten to 15 of the participants also reported values for Ba, Y, and Sc. Field parameters, major ion, and other trace element concentrations, not subject to statistical evaluation, are provided.
Coplen, Tyler B.; Qi, Haiping
2010-01-01
The δ2HVSMOW–SLAP value of total hydrogen of the international measurement standard NBS 22 oil was determined by a new method of sealing water in silver tubes for use in a thermal conversion elemental analysis (TC/EA) reduction unit. The isotopic fractionation of water due to evaporation is virtually non-existent in this silver-tube method. A new value for the δ2HVSMOW–SLAP of NBS 22 oil, calibrated with isotopic reference waters, was determined to be −116.9 ± 0.8‰ (1σ and n = 31).
Joel, E S; Maxwell, O; Adewoyin, O O; Ehi-Eromosele, C O; Embong, Z; Oyawoye, F
2018-01-01
In this study, we evaluated the activity concentration of natural radionuclides ( 226 Ra, 232 Th and 40 K) for fifteen (15) different brands of tile samples used for building purposes in Nigeria. The tile samples were analyzed using High purity Germanium gamma detector. The mean activity concentrations of 226 Ra, 232 Th, and 40 K were observed to be 61.1 ± 5.5 Bq/kg, 70.2 ± 6.08 Bq/kg and 514.7 ± 59.8 Bq/kg respectively. Various hazard indices such as absorbed dose rate, external and internal hazard index, annual effective dose rate, Gamma activity Index (Iγ) and Alpha Index (Iα) were calculated. The obtained results showed that the mean radium equivalent activity (Raeq), the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, Gamma activity Index (Iγ) and Alpha Index (Iα) were: 204.42 Bq/kg, 177.61 nGyh -1 , 0.55, 0.77, 0.96 mSvyr -1 , 0.74 and 0.32 respectively. The average value of radium equivalent obtained in this study is less than that of the recommended value of 370 Bq/kg but the average values of the other radiological hazards for some samples are found to be slightly above international recommended values except H ex , H in and AEDE which are within the international reference value of unity. The measured concentrations of these radioactive materials were correlated with other previous result obtained from similar tile materials used in other countries and found to be in good agreement with the international standard, however, the tiles are recommended for decoration purposes in Nigeria.
Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François
2009-11-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials. Copyright 2009 John Wiley & Sons, Ltd.
Cordeiro, F; Baer, I; Robouch, P; Emteborg, H; Can, S Z; Krata, A; Zampella, M; Quétel, C R; Hearn, R; De la Calle, B
2013-01-01
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate-General of the European Commission, operates the International Measurement Evaluation Programme® (IMEP). It organises various types of inter-laboratory comparisons in support of European Union policies. This paper presents the results of a proficiency testing exercise (PT) focusing on the determination of total cadmium (Cd) and total lead (Pb) mass fractions in baby food in support to Commission Regulation (EC) 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. The test material used in this exercise was soya-based baby food formula purchased in a local pharmacy and prepared by the Reference Materials Unit of the IRMM for this exercise. Sixty-six laboratories from 23 countries registered to the exercise and 61 of them reported results. Each participant received one bottle containing approximately 15 g of test material. Participants were asked to quantify the measurands in the powder and in the reconstituted formula. Reference values independent from the participants' results were established using isotope dilution inductively coupled plasma mass spectrometry. The total Cd mass fraction was determined by IRMM and LGC Ltd (UK), while the total Pb was determined by IRMM. The standard deviation for proficiency assessment σ^ was set at 22% of the assigned value for all measurands. Laboratories were rated with z- and ζ- (zeta) scores in accordance with ISO 13528. The outcome of this exercise is clearly influenced by the very low level of Cd and Pb content in the test material which triggered: a high number of 'less than' values; overestimated values especially for Pb very likely due to contamination; and a visible method influence in the case of Pb (methods based on atomic absorption were not sensitive enough to attain such low limits of detection). The results were also evaluated with regard to the reported limit of detection and some incoherencies were observed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdallah, I; Aly, A; Al Naemi, H
Purpose: The aim of this study was to evaluate radiation doses to pediatric patients undergoing standard radiographic examinations using Direct Digital Radiography (DDR) in Paediatric emergency center of Hamad General Hospital (HGH) in state of Qatar and compared with regional and international Dose Reference Levels (DRLs). Methods: Entrance Skin Dose (ESD) was measured for 2739 patients for two common X-ray examinations namely: Chest AP/PA, Abdomen. Exposure factors such as kV, mAs and Focal to Skin Distance (FSD) were recorded for each patient. Tube Output was measured for a range of selected kV values. ESD for each individual patient was calculatedmore » using the tube output and the technical exposure factors for each examination. The ESD values were compared with the some international Dose Reference Levels (DRL) for all types of examinations. Results: The most performed procedure during the time of this study was chest PA/PA (85%). The mean ESD values obtained from AP chest, PA chest and AP abdomen ranged 91–120, 80–84 and 209 – 659 µGy per radiograph for different age’s groups respectively. Two protocols have been used for chest AP and PA using different radiological parameters, and the different of ESD values for chest PA and were 41% for 1 years old child, 57% for 5 years old for chest AP. Conclusion: The mean ESD were compared with those found in literature and were found to be comparable. The radiation dose can be reduced more for Chest AP and PA examination by optimization of each investigation and hence more studies are required for this task. The results presented will serve as a baseline data needed for deriving local reference doses for pediatric X-ray examinations in this local department and hence it can be applied in the whole Qatar.« less
Designing robots for care: care centered value-sensitive design.
van Wynsberghe, Aimee
2013-06-01
The prospective robots in healthcare intended to be included within the conclave of the nurse-patient relationship--what I refer to as care robots--require rigorous ethical reflection to ensure their design and introduction do not impede the promotion of values and the dignity of patients at such a vulnerable and sensitive time in their lives. The ethical evaluation of care robots requires insight into the values at stake in the healthcare tradition. What's more, given the stage of their development and lack of standards provided by the International Organization for Standardization to guide their development, ethics ought to be included into the design process of such robots. The manner in which this may be accomplished, as presented here, uses the blueprint of the Value-sensitive design approach as a means for creating a framework tailored to care contexts. Using care values as the foundational values to be integrated into a technology and using the elements in care, from the care ethics perspective, as the normative criteria, the resulting approach may be referred to as care centered value-sensitive design. The framework proposed here allows for the ethical evaluation of care robots both retrospectively and prospectively. By evaluating care robots in this way, we may ultimately ask what kind of care we, as a society, want to provide in the future.
Bhaskaran, Eswaran; Azhagarasan, N S; Miglani, Saket; Ilango, T; Krishna, G Phani; Gajapathi, B
2013-09-01
Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.
Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Bohlke, John Karl; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.
2009-01-01
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:Reference materialδ18O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 ± 0.36‰USGS35 sodium nitrate+56.81 ± 0.31‰IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰IAEA-601 benzoic acid+23.14 ± 0.19‰IAEA-SO-5 barium sulfate+12.13 ± 0.33‰NBS 127 barium sulfate+8.59 ± 0.26‰VSMOW2 water0‰IAEA-600 caffeine−3.48 ± 0.53‰IAEA-SO-6 barium sulfate−11.35 ± 0.31‰USGS34 potassium nitrate−27.78 ± 0.37‰SLAP water−55.5‰The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary.The high-temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.
Review of utility values for economic modeling in type 2 diabetes.
Beaudet, Amélie; Clegg, John; Thuresson, Per-Olof; Lloyd, Adam; McEwan, Phil
2014-06-01
Economic analysis in type 2 diabetes mellitus (T2DM) requires an assessment of the effect of a wide range of complications. The objective of this article was to identify a set of utility values consistent with the National Institute for Health and Care Excellence (NICE) reference case and to critically discuss and illustrate challenges in creating such a utility set. A systematic literature review was conducted to identify studies reporting utility values for relevant complications. The methodology of each study was assessed for consistency with the NICE reference case. A suggested set of utility values applicable to modeling was derived, giving preference to studies reporting multiple complications and correcting for comorbidity. The review considered 21 relevant diabetes complications. A total of 16,574 articles were identified; after screening, 61 articles were assessed for methodological quality. Nineteen articles met NICE criteria, reporting utility values for 20 of 21 relevant complications. For renal transplant, because no articles meeting NICE criteria were identified, two articles using other methodologies were included. Index value estimates for T2DM without complication ranged from 0.711 to 0.940. Utility decrement associated with complications ranged from 0.014 (minor hypoglycemia) to 0.28 (amputation). Limitations associated with the selection of a utility value for use in economic modeling included variability in patient recruitment, heterogeneity in statistical analysis, large variability around some point estimates, and lack of recent data. A reference set of utility values for T2DM and its complications in line with NICE requirements was identified. This research illustrates the challenges associated with systematically selecting utility data for economic evaluations. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
De Carli, Luca; Spada, Elena; Milani, Silvano; Ganzit, Gian Pasquale; Ghizzoni, Lucia; Raia, Melissa; Coscia, Alessandra; Bertino, Enrico; Bo, Simona
2018-04-01
Since populations are becoming increasingly multi-ethnic, the use of local or international charts is a matter of debate. This study aimed to evaluate how the choice of cut-off thresholds affected prevalence of underweight (UW), overweight (OW), obesity (OB) in 1200 11-12-year Italian adolescents, and how their somatic growth depended on parental origin. The height, weight and body mass index were expressed as standard deviation score (SDS) using Italian (ISPED-2006) and UK (UK-1990) charts. The classification of UW/OW/OB was computed with the IOTF international cut-offs, and thresholds were identified as centiles corresponding to BMI values of 18.5/25.0/30.0 kg/m 2 at 18-year in ISPED-2006 or UK-1990 references. About 30% participants had non-Italian parents, above all from North-Africa and Romania. Referring to the UK-1990 charts, all groups showed negative mean SDS for height, and positive SDS for weight and BMI. Referring to the ISPED-2006 charts, all mean SDS were negative. Percentage of UW individuals was higher in accordance with ISPED-2006 than with UK-1990 charts, whereas percentages of OW/OB were higher with UK-1990 than ISPED-2006 charts. The results obtained using IOFT cut-offs were similar to UK-1990 cut-offs. These results were due to the different shape of age-dependent cut-off centiles. Independently by the parental origin, the percentages of adolescents classified as OW/OB were closer to the expected values using the ISPED-2006 then the UK-1990 cut-offs. The results suggested the use of the Italian references for adolescents with immigrant parents. The use of local charts seems more appropriate at least in Italian adolescents in the age range studied.
Antonacci, Michael A; Zhang, Le; Burant, Alex; McCallister, Drew; Branca, Rosa T
2018-08-01
To assess the effect of macroscopic susceptibility gradients on the gas-phase referenced dissolved-phase 129 Xe (DPXe) chemical shift (CS) and to establish the robustness of a water-based referencing system for in vivo DPXe spectra. Frequency shifts induced by spatially varying magnetic susceptibility are calculated by finite-element analysis for the human head and chest. Their effect on traditional gas-phase referenced DPXe CS is then assessed theoretically and experimentally. A water-based referencing system for the DPXe resonances that uses the local water protons as reference is proposed and demonstrated in vivo in rats. Across the human brain, macroscopic susceptibility gradients can induce an apparent variation in the DPXe CS of up to 2.5 ppm. An additional frequency shift as large as 6.5 ppm can exist between DPXe and gas-phase resonances. By using nearby water protons as reference for the DPXe CS, the effect of macroscopic susceptibility gradients is eliminated and consistent CS values are obtained in vivo, regardless of shimming conditions, region of interest analyzed, animal orientation, or lung inflation. Combining in vitro and in vivo spectroscopic measurements finally enables confident assignment of some of the DPXe peaks observed in vivo. To use hyperpolarized xenon as a biological probe in tissues, the DPXe CS in specific organs/tissues must be reliably measured. When the gas-phase is used as reference, variable CS values are obtained for DPXe resonances. Reliable peak assignments in DPXe spectra can be obtained by using local water protons as reference. Magn Reson Med 80:431-441, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Quality evaluation of no-reference MR images using multidirectional filters and image statistics.
Jang, Jinseong; Bang, Kihun; Jang, Hanbyol; Hwang, Dosik
2018-09-01
This study aimed to develop a fully automatic, no-reference image-quality assessment (IQA) method for MR images. New quality-aware features were obtained by applying multidirectional filters to MR images and examining the feature statistics. A histogram of these features was then fitted to a generalized Gaussian distribution function for which the shape parameters yielded different values depending on the type of distortion in the MR image. Standard feature statistics were established through a training process based on high-quality MR images without distortion. Subsequently, the feature statistics of a test MR image were calculated and compared with the standards. The quality score was calculated as the difference between the shape parameters of the test image and the undistorted standard images. The proposed IQA method showed a >0.99 correlation with the conventional full-reference assessment methods; accordingly, this proposed method yielded the best performance among no-reference IQA methods for images containing six types of synthetic, MR-specific distortions. In addition, for authentically distorted images, the proposed method yielded the highest correlation with subjective assessments by human observers, thus demonstrating its superior performance over other no-reference IQAs. Our proposed IQA was designed to consider MR-specific features and outperformed other no-reference IQAs designed mainly for photographic images. Magn Reson Med 80:914-924, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.
Serum free light chain reference values: a critical approach.
Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario
2013-05-01
The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.
In situ LTE exposure of the general public: Characterization and extrapolation.
Joseph, Wout; Verloock, Leen; Goeminne, Francis; Vermeeren, Günter; Martens, Luc
2012-09-01
In situ radiofrequency (RF) exposure of the different RF sources is characterized in Reading, United Kingdom, and an extrapolation method to estimate worst-case long-term evolution (LTE) exposure is proposed. All electric field levels satisfy the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels with a maximal total electric field value of 4.5 V/m. The total values are dominated by frequency modulation (FM). Exposure levels for LTE of 0.2 V/m on average and 0.5 V/m maximally are obtained. Contributions of LTE to the total exposure are limited to 0.4% on average. Exposure ratios from 0.8% (LTE) to 12.5% (FM) are obtained. An extrapolation method is proposed and validated to assess the worst-case LTE exposure. For this method, the reference signal (RS) and secondary synchronization signal (S-SYNC) are measured and extrapolated to the worst-case value using an extrapolation factor. The influence of the traffic load and output power of the base station on in situ RS and S-SYNC signals are lower than 1 dB for all power and traffic load settings, showing that these signals can be used for the extrapolation method. The maximal extrapolated field value for LTE exposure equals 1.9 V/m, which is 32 times below the ICNIRP reference levels for electric fields. Copyright © 2012 Wiley Periodicals, Inc.
Hudzik, Jason M; Bozzelli, Joseph W; Simmie, John M
2014-10-09
Standard enthalpies of formation (ΔH°f 298) of methyl, ethyl, primary and secondary propyl, and n-butyl radicals are evaluated and used in work reactions to determine internal consistency. They are then used to calculate the enthalpy of formation for the tert-butyl radical. Other thermochemical properties including standard entropies (S°(T)), heat capacities (Cp(T)), and carbon-hydrogen bond dissociation energies (C-H BDEs) are reported for n-pentane, n-heptane, 2-methylhexane, 2,3-dimethylpentane, and several branched higher carbon number alkanes and their radicals. ΔH°f 298 and C-H BDEs are calculated using isodesmic work reactions at the B3LYP (6-31G(d,p) and 6-311G(2d,2p) basis sets), CBS-QB3, CBS-APNO, and G3MP2B3 levels of theory. Structures, moments of inertia, vibrational frequencies, and internal rotor potentials are calculated at the B3LYP/6-31G(d,p) level for contributions to entropy and heat capacities. Enthalpy calculations for these hydrocarbon radical species are shown to have consistency with the CBS-QB3 and CBS-APNO methods using all work reactions. Our recommended ideal gas phase ΔH°f 298 values are from the average of all CBS-QB3, CBS-APNO, and for G3MP2B3, only where the reference and target radical are identical types, and are compared with literature values. Calculated values show agreement between the composite calculation methods and the different work reactions. Secondary and tertiary C-H bonds in the more highly branched alkanes are shown to have bond energies that are several kcal mol(-1) lower than the BDEs in corresponding smaller molecules often used as reference species. Entropies and heat capacities are calculated and compared to literature values (when available) when all internal rotors are considered.
1993-04-01
return because the Regardless of how the remainder of the clean- package would have a higher franchise value up is funded, structured, or scheduled...estate assets); change in interest rates, reflect changing macroeconomic conditions. These events also 8. Changes in the tax law. may not be repeated... International Perspective," Bank of England Quarterly refers to funds being intermediated by financial institu- Bulletin, vol. 31, no. I tFebruary
van Haarst, Ernst P; Bosch, J L H Ruud
2012-09-01
We sought criteria for nocturnal polyuria in asymptomatic, nonurological adults of all ages by reporting reference values of the ratio of daytime and nighttime urine volumes, and finding nocturia predictors. Data from a database of frequency-volume charts from a reference population of 894 nonurological, asymptomatic volunteers of all age groups were analyzed. The nocturnal polyuria index and the nocturia index were calculated and factors influencing these values were determined by multivariate analysis. The nocturnal polyuria index had wide variation but a normal distribution with a mean ± SD of 30% ± 12%. The 95th percentile of the values was 53%. Above this cutoff a patient had nocturnal polyuria. This value contrasts with the International Continence Society definition of 33% but agrees with several other reports. On multivariate regression analysis with the nocturnal polyuria index as the dependent variable sleeping time, maximum voided volume and age were the covariates. However, the increase in the nocturnal polyuria index by age was small. Excluding polyuria and nocturia from analysis did not alter the results in a relevant way. The nocturnal voiding frequency depended on sleeping time and maximum voided volume but most of all on the nocturia index. The prevalence of nocturnal polyuria is overestimated. We suggest a new cutoff value for the nocturnal polyuria index, that is nocturnal polyuria exists when the nocturnal polyuria index exceeds 53%. The nocturia index is the best predictor of nocturia. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Realization of ETRF2000 as a New Terrestrial Reference Frame in Republic of Serbia
NASA Astrophysics Data System (ADS)
Blagojevic, D.; Vasilic, V.
2012-12-01
The International Earth Rotation and Reference Systems Service (IERS) is a joint service of the International Association of Geodesy (IAG) and the International Astronomical Union (IAU), which provides the scientific community with the means for computing the transformation from the International Celestial Reference System (ICRS) to the International Terrestrial Reference System (ITRS). It further maintains the realizations of these systems by appropriate coordinate sets called "frames". The densification of terrestrial frame usually serves as official frame for positioning and navigation tasks within the territory of particular country. One of these densifications was recently performed in order to establish new reference frame for Republic of Serbia. The paper describes related activities resulting in ETRF2000 as a new Serbian terrestrial reference frame.
Certified reference materials (GBW09170 and 09171) of creatinine in human serum.
Dai, Xinhua; Fang, Xiang; Shao, Mingwu; Li, Ming; Huang, Zejian; Li, Hongmei; Jiang, You; Song, Dewei; He, Yajuan
2011-02-15
Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Han Sung; Yeom, Yeon Soo; Tat Nguyen, Thang; Choi, Chansoo; Han, Min Cheol; Lee, Jai Ki; Kim, Chan Hyeong; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Qiu, Rui; Eckerman, Keith; Chung, Beom Sun
2017-03-01
It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.
Tam, Kim-Pong; Lee, Sau-Lai; Kim, Young-Hoon; Li, Yanmei; Chao, Melody Manchi
2012-08-01
What values do parents want to transmit to children? The intersubjective model of value transmission posits that parents want to transmit not only the values they personally endorse but also the values they perceive to be normatively important in the society. The present research shows support to this premise. Furthermore, Studies 1 and 2 revealed that the use of perceived norms is moderated by families' social contexts and parents' personality: It was particularly pronounced among parents who were immigrants, who had a stronger need for closure, and who were more conforming. In addition, Studies 3 and 4 demonstrated that parents' perceived norms can explain actual value transmission: Values parents perceived to be normatively important were to some extent internalized by children. The intersubjective model paves some new directions for value transmission research, contributes to the understanding of cultural transmission and cultural change, and extends the intersubjective approach to culture.
Gillard, Jonathan
2015-12-01
This article re-examines parametric methods for the calculation of time specific reference intervals where there is measurement error present in the time covariate. Previous published work has commonly been based on the standard ordinary least squares approach, weighted where appropriate. In fact, this is an incorrect method when there are measurement errors present, and in this article, we show that the use of this approach may, in certain cases, lead to referral patterns that may vary with different values of the covariate. Thus, it would not be the case that all patients are treated equally; some subjects would be more likely to be referred than others, hence violating the principle of equal treatment required by the International Federation for Clinical Chemistry. We show, by using measurement error models, that reference intervals are produced that satisfy the requirement for equal treatment for all subjects. © The Author(s) 2011.
Certification of reference materials for the determination of alkylphenols.
Hanari, Nobuyasu; Ishikawa, Keiichiro; Shimizu, Yoshitaka; Otsuka, Satoko; Iwasawa, Ryoko; Fujiki, Naomi; Numata, Masahiko; Yarita, Takashi; Kato, Kenji
2015-04-01
Certified reference materials (CRMs) are playing an increasingly important role in national and international standardizing activities. In Japan, primary standard solutions for analyses of endocrine disrupters are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). For the traceability on reference materials used for preparation of the primary standard solutions based on the JCSS, the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed and certified high-purity reference materials of alkylphenols as NMIJ CRMs, such as 4-n-nonylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-tert-butylphenol, and 2,4-dichlorophenol. Thereafter, it is essential to determine the alkylphenols by using these solutions based on the JCSS for environmental monitoring and risk assessments because analytical values obtained by using the solutions can ensure the reliability and traceability of the chemical analyses.
Growth references for Tsimane forager-horticulturalists of the Bolivian Amazon
Blackwell, Aaron D.; Urlacher, Samuel S.; Beheim, Bret; von Rueden, Christopher; Jaeggi, Adrian; Stieglitz, Jonathan; Trumble, Benjamin C.; Gurven, Michael; Kaplan, Hillard
2016-01-01
Objectives Growth standards and references currently used to assess population and individual health are derived primarily from urban populations, including few individuals from indigenous or subsistence groups. Given environmental and genetic differences, growth may vary in these populations. Thus, there is a need to assess whether international standards are appropriate for all populations, and to produce population specific references if growth differs. Here we present and assess growth references for the Tsimane, an indigenous population of Bolivian forager-horticulturalists. Methods Mixed cross-sectional/longitudinal anthropometrics (9,614 individuals; 30,118 observations; ages 0–29 years) were used to generate centile curves and Lambda-Mu-Sigma (LMS) tables for height-for-age, weight-for-age, body mass index (BMI)-for-age, and weight-for-height (WFH) using Generalized Additive Models for Location Shape and Scale (GAMLSS). Velocity curves were generated using SuperImposition by Translation and Rotation (SITAR). Tsimane ≤5 years were compared World Health Organization (WHO) standards while those >5 years were compared to WHO school age references. All ages were compared to published references for Shuar forager-horticulturalists of the Ecuadorian Amazon. Results Tsimane growth differs from WHO values in height and weight, but is similar for BMI and WFH. Tsimane growth is characterized by slow height velocity in childhood and early adolescent peak height velocity at 11.3 and 13.2 years for girls and boys. Tsimane growth patterns are similar to Shuar, suggesting shared features of growth among indigenous South Americans. Conclusions International references for BMI-for-age and WFH are likely appropriate for Tsimane, but differences in height-for-age and weight-for-age suggest Tsimane specific references may be useful for these measures. PMID:28218400
Growth references for Tsimane forager-horticulturalists of the Bolivian Amazon.
Blackwell, Aaron D; Urlacher, Samuel S; Beheim, Bret; von Rueden, Christopher; Jaeggi, Adrian; Stieglitz, Jonathan; Trumble, Benjamin C; Gurven, Michael; Kaplan, Hillard
2017-03-01
Growth standards and references currently used to assess population and individual health are derived primarily from urban populations, including few individuals from indigenous or subsistence groups. Given environmental and genetic differences, growth may vary in these populations. Thus, there is a need to assess whether international standards are appropriate for all populations, and to produce population specific references if growth differs. Here we present and assess growth references for the Tsimane, an indigenous population of Bolivian forager-horticulturalists. Mixed cross-sectional/longitudinal anthropometrics (9,614 individuals; 30,118 observations; ages 0-29 years) were used to generate centile curves and Lambda-Mu-Sigma (LMS) tables for height-for-age, weight-for-age, body mass index (BMI)-for-age, and weight-for-height (WFH) using Generalized Additive Models for Location Shape and Scale (GAMLSS). Velocity curves were generated using SuperImposition by Translation and Rotation (SITAR). Tsimane ≤5 years were compared to World Health Organization (WHO) standards while those >5 years were compared to WHO school age references. All ages were compared to published references for Shuar forager-horticulturalists of the Ecuadorian Amazon. Tsimane growth differs from WHO values in height and weight, but is similar for BMI and WFH. Tsimane growth is characterized by slow height velocity in childhood and early adolescent peak height velocity at 11.3 and 13.2 years for girls and boys. Tsimane growth patterns are similar to Shuar, suggesting shared features of growth among indigenous South Americans. International references for BMI-for-age and WFH are likely appropriate for Tsimane, but differences in height-for-age and weight-for-age suggest Tsimane specific references may be useful for these measures. © 2016 Wiley Periodicals, Inc.
An Impedance-Based Mold Sensor with on-Chip Optical Reference
Papireddy Vinayaka, Poornachandra; van den Driesche, Sander; Blank, Roland; Tahir, Muhammad Waseem; Frodl, Mathias; Lang, Walter; Vellekoop, Michael J.
2016-01-01
A new miniaturized sensor system with an internal optical reference for the detection of mold growth is presented. The sensor chip comprises a reaction chamber provided with a culture medium that promotes the growth of mold species from mold spores. The mold detection is performed by measuring impedance changes with integrated electrodes fabricated inside the reaction chamber. The impedance change in the culture medium is caused by shifts in the pH (i.e., from 5.5 to 8) as the mold grows. In order to determine the absolute pH value without the need for calibration, a methyl red indicator dye has been added to the culture medium. It changes the color of the medium as the pH passes specific values. This colorimetric principle now acts as a reference measurement. It also allows the sensitivity of the impedance sensor to be established in terms of impedance change per pH unit. Major mold species that are involved in the contamination of food, paper and indoor environments, like Fusarium oxysporum, Fusarium incarnatum, Eurotium amstelodami, Aspergillus penicillioides and Aspergillus restrictus, have been successfully analyzed on-chip. PMID:27690039
Katja — the 24th week of virtual pregnancy for dosimetric calculations
NASA Astrophysics Data System (ADS)
Becker, Janine; Zankl, Maria; Fill, Ute; Hoeschen, Christoph
2008-01-01
Virtual human models, a.k.a. voxel models, are currently the
Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code.
Yoriyaz, H; dos Santos, A; Stabin, M G; Cabezas, R
2000-07-01
A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. MCNP-4B absorbed fractions for photons in the mathematical phantom of Snyder et al. agreed well with reference values. Results obtained through radiation transport simulation in the voxel-based phantom, in general, agreed well with reference values. Considerable discrepancies, however, were found in some cases due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom, which is not considered in the mathematical phantom.
Advanced Life Support Research and Technology Development Metric
NASA Technical Reports Server (NTRS)
Hanford, A. J.
2004-01-01
The Metric is one of several measures employed by the NASA to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2004. The values are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. For Fiscal Year 2004, the Advanced Life Support Research and Technology Development Metric value is 2.03 for an Orbiting Research Facility and 1.62 for an Independent Exploration Mission.
Findlay, R P; Dimbylow, P J
2009-04-21
If an antenna is located close to a person, the electric and magnetic fields produced by the antenna will vary in the region occupied by the human body. To obtain a mean value of the field for comparison with reference levels, the Institute of Electrical and Electronic Engineers (IEEE) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommend spatially averaging the squares of the field strength over the height the body. This study attempts to assess the validity and accuracy of spatial averaging when used for half-wave dipoles at frequencies between 65 MHz and 2 GHz and distances of lambda/2, lambda/4 and lambda/8 from the body. The differences between mean electric field values calculated using ten field measurements and that of the true averaged value were approximately 15% in the 600 MHz to 2 GHz range. The results presented suggest that the use of modern survey equipment, which takes hundreds rather than tens of measurements, is advisable to arrive at a sufficiently accurate mean field value. Whole-body averaged and peak localized SAR values, normalized to calculated spatially averaged fields, were calculated for the NORMAN voxel phantom. It was found that the reference levels were conservative for all whole-body SAR values, but not for localized SAR, particularly in the 1-2 GHz region when the dipole was positioned very close to the body. However, if the maximum field is used for normalization of calculated SAR as opposed to the lower spatially averaged value, the reference levels provide a conservative estimate of the localized SAR basic restriction for all frequencies studied.
Shipitsyna, E; Zolotoverkhaya, E; Hjelmevoll, S O; Maximova, A; Savicheva, A; Sokolovsky, E; Skogen, V; Domeika, M; Unemo, M
2009-11-01
In Russia, laboratory diagnosis of gonorrhoea has been mainly based on microscopy only and, in some settings, relatively rare suboptimal culturing. In recent years, Russian developed and manufactured nucleic acid amplification tests (NAAT) have been implemented for routine diagnosis of Neisseria gonorrhoeae. However, these NAATs have never been validated to any international well-recognized diagnostic NAAT. This study aims to evaluate the performance characteristics of six Russian NAATs for N. gonorrhoeae diagnostics. In total, 496 symptomatic patients were included. Five polymerase chain reaction (PCR) assays and one real-time nucleic acid sequence based amplification (NASBA) assay, developed by three Russian companies, were evaluated on urogenital samples, i.e. cervical and first voided urine (FVU) samples from females (n = 319), urethral and FVU samples from males (n = 127), and extragenital samples, i.e. rectal and pharyngeal samples, from 50 additional female patients with suspicion of gonorrhoea. As reference method, an international strictly validated real-time porA pseudogene PCR was applied. The prevalence of N. gonorrhoeae was 2.7% and 16% among the patients providing urogenital and extragenital samples, respectively. The Russian NAATs and the reference method displayed high level of concordance (99.4-100%). The sensitivities, specificities, positive predictive values and negative predictive values of the Russian tests in different specimens were 66.7-100%, 100%, 100%, and 99.4-100%, respectively. Russian N. gonorrhoeae diagnostic NAATs comprise relatively good performance characteristics. However, larger studies are crucial and, beneficially, the Russian assays should also be evaluated to other international highly sensitive and specific, and ideally Food and Drug Administration approved, NAATs such as Aptima Combo 2 (Gen-Probe).
Sharpless, K E; Gill, L M
2000-01-01
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.
42 CFR 424.507 - Ordering and referring covered items and services for Medicare beneficiaries.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ordered or referred by a resident or an intern, the claim must identify the teaching physician as the... referred by a resident or an intern, the claim must identify the teaching physician as the ordering or... intern, the claim must identify the teaching physician as the ordering or referring physician. The claim...
42 CFR 424.507 - Ordering and referring covered items and services for Medicare beneficiaries.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ordered or referred by a resident or an intern, the claim must identify the teaching physician as the... referred by a resident or an intern, the claim must identify the teaching physician as the ordering or... intern, the claim must identify the teaching physician as the ordering or referring physician. The claim...
Middleton, John; Vaks, Jeffrey E
2007-04-01
Errors of calibrator-assigned values lead to errors in the testing of patient samples. The ability to estimate the uncertainties of calibrator-assigned values and other variables minimizes errors in testing processes. International Organization of Standardization guidelines provide simple equations for the estimation of calibrator uncertainty with simple value-assignment processes, but other methods are needed to estimate uncertainty in complex processes. We estimated the assigned-value uncertainty with a Monte Carlo computer simulation of a complex value-assignment process, based on a formalized description of the process, with measurement parameters estimated experimentally. This method was applied to study uncertainty of a multilevel calibrator value assignment for a prealbumin immunoassay. The simulation results showed that the component of the uncertainty added by the process of value transfer from the reference material CRM470 to the calibrator is smaller than that of the reference material itself (<0.8% vs 3.7%). Varying the process parameters in the simulation model allowed for optimizing the process, while keeping the added uncertainty small. The patient result uncertainty caused by the calibrator uncertainty was also found to be small. This method of estimating uncertainty is a powerful tool that allows for estimation of calibrator uncertainty for optimization of various value assignment processes, with a reduced number of measurements and reagent costs, while satisfying the requirements to uncertainty. The new method expands and augments existing methods to allow estimation of uncertainty in complex processes.
Improved reliability of pH measurements.
Spitzer, Petra; Werner, Barbara
2002-11-01
Measurements of pH are performed on a large scale at laboratory level, and in industry. To meet the quality-control requirements and other technical specifications there is a need for traceability in measurement results. The prerequisite for the international acceptance of analytical data is reliability. To measure means to compare. Comparability entails use of recognised references to which the standard buffer solutions used for calibration of pH meter-electrode assemblies can be traced. The new recommendation on the measurement of pH recently published as a provisional document by the International Union on Pure and Applied Chemistry (IUPAC) enables traceability for measured pH values to a conventional reference frame which is recognised world-wide. The primary method for pH will be described. If analytical data are to be accepted internationally it is necessary to demonstrate the equivalence of the national traceability structures, including national measurement standards. For the first time key comparisons for pH have been performed by the Consultative Committee for Amount of Substance (CCQM, set up by the International Bureau of Weights and Measures, BIPM) to assess the equivalence of the national measurement procedures used to determine the pH of primary standard buffer solutions. The results of the first key comparison on pH CCQM-K9, and other international initiatives to improve the consistency of the results of measurement for pH, are reported.
Tsetlin, E M; Volkova, R A
1996-01-01
Ninety-eight lots of commercial antirabies vaccine manufactured by Immunopreparat Research and Production Amalgamation have been tested using enzyme immunoassay system for the detection of rabies virus antigens. Comparison of different variants of interpreting and expressing the results helped define the optimal method for assessment of vaccine titer and reference values: optical density value equal to 0.2 is taken as the cut-off. Antigenic activity of the vaccine may be expressed in international units, similarly as immunogenic activity.
Vörös, Károly; Hetyey, Csaba; Reiczigel, Jeno; Czirok, Gábor Nagy
2009-06-01
The aim of the study was to establish normal reference echocardiographic values for three Hungarian dog breeds, and to determine the potential dependence of intracardiac parameters on body weight, age and gender. M-mode and two-dimensional echocardiography were performed on 95 clinically healthy dogs including 45 Hungarian Vizslas, 28 Mudis and 22 Hungarian Greyhounds. Linear intracardiac measurements included interventricular septal thickness (IVS), left ventricular internal diameter (LVID), left ventricular posterior wall thickness (LVPW) both in systole and diastole, as well as left atrial internal diameter (LAD), and aortic diameter (AOD) in early diastole. Fractional shortening (FS), end-diastolic and end-systolic left ventricular volumes (EDV and ESV), as well as LAD:AOD ratio were calculated from the linear parameters. Mean, range and standard deviation of measurements were calculated for each breed. Body weight positively correlated in all three breeds with all left ventricular dimensions, such as IVS d , IVS s , LVID d , LVIDD s , LVPW d and LVPW s parameters. LA values showed positive correlations to body weight in all three breeds. AOD and LA demonstrated a positive correlation with body weight in Hungarian Vizslas and Mudis, whilst the LAD:AOD ratio was related to body weight only in Mudis. Gender did not correlate with any of the measured echocardiographic parameters in any breeds. In Mudis, a positive correlation was found between the LAD: AOD ratio and age, as well as between the LAD: AOD ratio and E point to septal separation (EPSS).
Ram, E; Marcus, O; Joubran, S; Abdo, B; Asal, N R
2013-12-01
Lack of published data. Absence of Ethnic specific data. Lack of focus on obesity prevention in Arab schools. First set of data on obesity for Arab children. Data will be used as reference data. Alert health/school official for intervention. Objective The objective is to produce the first set of obesity prevalence data and use the data as reference values of body mass index (BMI) trends for Arab children in Israel and compare with Jewish and international data. Methods A prevalence study was carried out in 2009 in which 4130 children aged 6-12, were selected from eight Arab sector schools representing the Nazareth Municipality. Height, weight and BMI measurements were obtained and presented by age, mean age, size, weight, gender and percentile. Appropriate epidemiological and statistical methods used for comparison. Results The obesity and overweight prevalence rates in Arab children by age ranges from 0% to 2.6% and 0% to 11.2%, respectively. Comparison with international and Jewish data revealed differences in almost all age groups but higher rates in Arabs, especially boys. Discussion The higher rates/trends in Arab children may be explained by more Arab women entering the workforce, increase in single-parent families and changes in food and physical activity environments. Conclusion Based on our data, we recommend either an ethnic-specific BMI reference curves and/or inclusion of Arab data in the Israeli data system. Research need to focus on reasons for the increase and interventions to reverse/slow the trend. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.
de Gois, Jefferson S; Vallelonga, Paul; Spolaor, Andrea; Devulder, Veerle; Borges, Daniel L G; Vanhaecke, Frank
2016-01-01
A simple and accurate methodology for Br isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) with pneumatic nebulization for sample introduction was developed. The Br(+) signals could be measured interference-free at high mass resolution. Memory effects for Br were counteracted using 5 mmol L(-1) of NH4OH in sample, standard, and wash solutions. The major cation load of seawater was removed via cation exchange chromatography using Dowex 50WX8 resin. Subsequent Br preconcentration was accomplished via evaporation of the sample solution at 90 °C, which did not induce Br losses or isotope fractionation. Mass discrimination was corrected for by external correction using a Cl-matched standard measured in a sample-standard bracketing approach, although Sr, Ge, and Se were also tested as potential internal standards for internal correction for mass discrimination. The δ(81)Br (versus standard mean ocean bromide (SMOB)) values thus obtained for the NaBr isotopic reference material NIST SRM 977 and for IRMM BCR-403 seawater certified reference material are in agreement with literature values. For NIST SRM 977, the (81)Br/(79)Br ratio (0.97291) was determined with a precision ≤0.08‰ relative standard deviation (RSD).
KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4
NASA Astrophysics Data System (ADS)
Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.
2008-01-01
Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1
NASA Astrophysics Data System (ADS)
Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.
2008-01-01
Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
The Third International Reference Preparation of Egg Lecithin
Krag, P.; Bentzon, M. Weis
1961-01-01
The Third International Reference Preparation of Egg Lecithin was produced (in a quantity of 5000 ml) at the WHO Serological Reference Centre, Copenhagen, and assayed in 1958 against the Second International Reference Preparation by four laboratories in three countries. Complement-fixation and slide-flocculation tests were used. The new preparation was found acceptable, and its establishment was authorized by the WHO Expert Committee on Biological Standardization. The average log10 titres and results of analyses of variances are shown. The variances were of the usual order of magnitude, and the differences in titre between antigens containing the Second and the Third International Reference Preparations varied from -0.011 to 0.116; only one of the differences exceeded the 5% limit of significance. The use of the Third International Reference Preparation in tests for the acceptability of lecithin preparations is described. PMID:13753864
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1976-01-01
An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. The 20 cells were manufactured for the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The cells are from a lot of 175 cells procured for the International Ultraviolet Explorer project. Due to a change in requirements, the project selected to use 6.0 ampere-hour cells. Therefore, the remaining cells of this lot have been placed in storage at GSFC for use on a future GSFC project. All the cells are rated at 12.0 ampere-hours and contain double ceramic seals. Test limits specify those values in which a cell is to be terminated from a particular charge or discharge. Requirements are referred to as normally expected values based on past performance of aerospace nickel cadmium cells with demonstrated life characteristics.
NASA Astrophysics Data System (ADS)
Demyanov, A. A.; Tsurko, A. A.
2017-01-01
In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Demyanov, A. A.; Tsurko, A. A.
2017-01-01
In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Beiras, Ricardo; Durán, Iria
2014-12-01
Some relevant shortcomings have been identified in the current approach for the classification of ecological status in marine water bodies, leading to delays in the fulfillment of the Water Framework Directive objectives. Natural variability makes difficult to settle fixed reference values and boundary values for the Ecological Quality Ratios (EQR) for the biological quality elements. Biological responses to environmental degradation are frequently of nonmonotonic nature, hampering the EQR approach. Community structure traits respond only once ecological damage has already been done and do not provide early warning signals. An alternative methodology for the classification of ecological status integrating chemical measurements, ecotoxicological bioassays and community structure traits (species richness and diversity), and using multivariate analyses (multidimensional scaling and cluster analysis), is proposed. This approach does not depend on the arbitrary definition of fixed reference values and EQR boundary values, and it is suitable to integrate nonlinear, sensitive signals of ecological degradation. As a disadvantage, this approach demands the inclusion of sampling sites representing the full range of ecological status in each monitoring campaign. National or international agencies in charge of coastal pollution monitoring have comprehensive data sets available to overcome this limitation.
Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra
2015-11-15
Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Schlattl, H.; Zankl, M.; Petoussi-Henss, N.
2007-04-01
A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.
1987-01-01
Scientific symposia on haemoglobinometry were held at the 9th Congress of the European Society of Haematology, Lisbon, 1963 (ESH 1964) and the 10th Congress of the International Society of Haematology (ISH), Stockholm, 1964 (ISH 1965). The International Committee for Standardization in Haematology (ICSH) made recommendations endorsed by the General Assembly of ICSH in Sydney on 23 August 1966 (ICSH 1967), for a reference method for haemoglobinometry and for the manufacture and distribution of an international reference preparation. Further symposia were held at the 12th Congress of the ISH, New York, 1968 (Astaldi, Sirtori & Vanzetti 1979) and at the 13th Congress of ISH, Munich, 1970 (Izak & Lewis 1972). The recommendations were reissued in 1978 (ISH 1978). On the basis of continuing experimental studies, the reference method and the specifications for the international reference preparation have been modified. The revised recommendations are described in this document.
Specification of ISS Plasma Environment Variability
NASA Technical Reports Server (NTRS)
Minow, Joseph I.; Neergaard, Linda F.; Bui, Them H.; Mikatarian, Ronald R.; Barsamian, H.; Koontz, Steven L.
2004-01-01
Quantifying spacecraft charging risks and associated hazards for the International Space Station (ISS) requires a plasma environment specification for the natural variability of ionospheric temperature (Te) and density (Ne). Empirical ionospheric specification and forecast models such as the International Reference Ionosphere (IRI) model typically only provide long term (seasonal) mean Te and Ne values for the low Earth orbit environment. This paper describes a statistical analysis of historical ionospheric low Earth orbit plasma measurements from the AE-C, AE-D, and DE-2 satellites used to derive a model of deviations of observed data values from IRI-2001 estimates of Ne, Te parameters for each data point to provide a statistical basis for modeling the deviations of the plasma environment from the IRI model output. Application of the deviation model with the IRI-2001 output yields a method for estimating extreme environments for the ISS spacecraft charging analysis.
Identifying Pediatric Severe Sepsis and Septic Shock: Accuracy of Diagnosis Codes.
Balamuth, Fran; Weiss, Scott L; Hall, Matt; Neuman, Mark I; Scott, Halden; Brady, Patrick W; Paul, Raina; Farris, Reid W D; McClead, Richard; Centkowski, Sierra; Baumer-Mouradian, Shannon; Weiser, Jason; Hayes, Katie; Shah, Samir S; Alpern, Elizabeth R
2015-12-01
To evaluate accuracy of 2 established administrative methods of identifying children with sepsis using a medical record review reference standard. Multicenter retrospective study at 6 US children's hospitals. Subjects were children >60 days to <19 years of age and identified in 4 groups based on International Classification of Diseases, Ninth Revision, Clinical Modification codes: (1) severe sepsis/septic shock (sepsis codes); (2) infection plus organ dysfunction (combination codes); (3) subjects without codes for infection, organ dysfunction, or severe sepsis; and (4) infection but not severe sepsis or organ dysfunction. Combination codes were allowed, but not required within the sepsis codes group. We determined the presence of reference standard severe sepsis according to consensus criteria. Logistic regression was performed to determine whether addition of codes for sepsis therapies improved case identification. A total of 130 out of 432 subjects met reference SD of severe sepsis. Sepsis codes had sensitivity 73% (95% CI 70-86), specificity 92% (95% CI 87-95), and positive predictive value 79% (95% CI 70-86). Combination codes had sensitivity 15% (95% CI 9-22), specificity 71% (95% CI 65-76), and positive predictive value 18% (95% CI 11-27). Slight improvements in model characteristics were observed when codes for vasoactive medications and endotracheal intubation were added to sepsis codes (c-statistic 0.83 vs 0.87, P = .008). Sepsis specific International Classification of Diseases, Ninth Revision, Clinical Modification codes identify pediatric patients with severe sepsis in administrative data more accurately than a combination of codes for infection plus organ dysfunction. Copyright © 2015 Elsevier Inc. All rights reserved.
Wolff, Peter Th; Arison, Lala; Rahajamiakatra, Abel; Raserijaona, Francis; Niggemann, Bodo
2014-01-01
Studies about children with respiratory diseases in Africa are impeded by the dearth of reliable data for the vast majority of countries on the continent. This study was conducted to establish representative reference values, therefore allowing a more accurate evaluation of lung function in Malagasy children. One thousand two hundred thirty-six students from three public and five private schools aged 8-12 years were recruited. A total of 1,093 children were healthy, had a valid lung function measurement and were thus deemed evaluable for this study. Lung function data were collected on consecutive days in Antananarivo, Madagascar's capital, using spirometry and a modified International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire. The lung volumes found were substantially lower compared to Caucasian and African equations. The mean Z-score (Stanojevic) for the forced vital capacity (FVC) found was -1.45 and -0.93 for the forced expiratory volume in 1 sec (FEV1) with significant differences between private and public schools (FVC: P = 0.0023, FEV1: P = 0.0004). The equations established for school children in Madagascar's capital Antananarivo showed lung function values were lower than reference values for the same age group seen not only in European, but also in African American and African children. The unique ethnicity of the Malagasy people, which combines Southeast-Asian with substantial African influences, the heavy burden of pollution and poverty may explain these differences. © 2013 Wiley Periodicals, Inc.
26 CFR 49.4253-12 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 49.4253-12 Section 49.4253-12 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES FACILITIES AND SERVICES EXCISE TAXES Communications § 49.4253-12 Cross reference. For exemptions...
26 CFR 44.4906-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 44.4906-1 Section 44.4906-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE... Taxes on Wagering General Provisions Relating to Occupational Taxes § 44.4906-1 Cross reference. For...
26 CFR 1.162-16 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Cross reference. 1.162-16 Section 1.162-16 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.162-16 Cross reference...
Investigation of the Application of miR10b and miR135b in the Identification of Semen Stains
Xue, Tianyu; Ma, Xiaoyan; Zhang, Jinxiang; Ou, Xueling; Cheng, Jianding; Sun, Hongyu
2015-01-01
To evaluate the identification method using the microRNA markers miR10b and miR135b to distinguish semen stains from menstrual blood, peripheral blood, vaginal fluid and so on body fluid stains. The expression levels of miR10b and miR35b in semen stains and menstrual blood and so on were detected utilizing a real-time quantitative PCR technique with a specific fluorescence-labeled TaqMan probe. RNU6b was used as the internal reference gene; the difference in their expression was analyzed, and the specificity, sensitivity, and detection capability of the techniques were evaluated. The expression of miR10b and miR135b in semen stains was significantly higher than that of other body fluid stains, with a mean value of ΔCт from-6 to-7. However, it ranged from-2 to-4 for other body fluid stains. The initial criteria for judging which semen stains can be identified were determined by analyzing the research results. When the threshold value was set to 0.04, the CT value could be detected in the target genes miR10b, miR135b and in the internal reference gene RNU6b, and CT values are<40, ΔCT[10b-U6]<-5.5, and ΔCT[135b-U6]<-6, respectively, and the semen stain could be identified. The expression levels of miR10b and miR135b are higher in semen with strong tissue specificity; thus, they can be used to differentiate semen stains from other body fluid stains in forensic science. PMID:26355456
Sönmez, Mehmet Giray; Göğer, Yunus Emre; Sönmez, Leyla Öztürk; Aydın, Arif; Balasar, Mehmet; Kara, Cengiz
2016-01-01
Blood count parameters of patients referring with erectile dysfunction (ED) were examined in this study and it was investigated whether eosinophil count (EC), platelet count (PC), and mean platelet volume values among the suspected predictive parameters which may play a role in especially penile arteriogenic ED etiopathogenesis had a contribution on pathogenesis. Patients referring with ED complaint were evaluated. Depending on the medical story, ED degree was determined by measuring International Index of Erectile Function. Penile Doppler ultrasonography was taken in patients suspected to have vasculogenic ED. According to penile Doppler ultrasonography result, patients with arterial deficiency were included in the penile arteriogenic ED group and the patients with normal results were included in the nonvasculogenic ED group. A total of 36 patients participated in the study from the penile arteriogenic ED group and 32 patients from the nonvasculogenic ED group. Compared with the nonvasculogenic ED group, the penile arteriogenic ED group’s low International Index of Erectile Function score, high EC, mean platelet volume and PC values were detected to be statistically significant (p < .001, p = .021, p = .018, p = .034, respectively). No statistically significant difference was observed among the two groups when age, white blood cells, red blood cells, and hemoglobin values were considered. Pansystolic volume velocities were detected as statistically significantly low compared with the nonvasculogenic ED group in the measurements made in 5th, 10th, 15th, and 20th minutes on the right and left sides in the penile arteriogenic ED group. High MPV value and PC is a significant predictive factor for penile arteriogenic ED and vasculogenic ED and high EC is specifically predictive of arteriogenic ED. PMID:27895254
Carrillo, Maria C; Blennow, Kaj; Soares, Holly; Lewczuk, Piotr; Mattsson, Niklas; Oberoi, Pankaj; Umek, Robert; Vandijck, Manu; Salamone, Salvatore; Bittner, Tobias; Shaw, Leslie M; Stephenson, Diane; Bain, Lisa; Zetterberg, Henrik
2013-03-01
Recognizing that international collaboration is critical for the acceleration of biomarker standardization efforts and the efficient development of improved diagnosis and therapy, the Alzheimer's Association created the Global Biomarkers Standardization Consortium (GBSC) in 2010. The consortium brings together representatives of academic centers, industry, and the regulatory community with the common goal of developing internationally accepted common reference standards and reference methods for the assessment of cerebrospinal fluid (CSF) amyloid β42 (Aβ42) and tau biomarkers. Such standards are essential to ensure that analytical measurements are reproducible and consistent across multiple laboratories and across multiple kit manufacturers. Analytical harmonization for CSF Aβ42 and tau will help reduce confusion in the AD community regarding the absolute values associated with the clinical interpretation of CSF biomarker results and enable worldwide comparison of CSF biomarker results across AD clinical studies. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Sanders, B. W.
1980-01-01
The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.
26 CFR 1.503(d)-1 - Cross references.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Cross references. 1.503(d)-1 Section 1.503(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Exempt Organizations § 1.503(d)-1 Cross references. For provisions relating to...
26 CFR 1.811-3 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.811-3 Section 1.811-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Gain and Loss from Operations § 1.811-3 Cross-reference. For special rules regarding the...
26 CFR 301.9001-3 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Cross reference. 301.9001-3 Section 301.9001-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND... reference. See the Coast Guard regulations under 33 CFR parts 135 and 136 for rules relating to the...
26 CFR 1.812-9 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.812-9 Section 1.812-9 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Gain and Loss from Operations § 1.812-9 Cross-reference. For special rules regarding the...
26 CFR 1.807-2 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.807-2 Section 1.807-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Investment Income § 1.807-2 Cross-reference. For special rules regarding the treatment of...
26 CFR 1.681(b)-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross reference. 1.681(b)-1 Section 1.681(b)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Miscellaneous § 1.681(b)-1 Cross reference. For disallowance of certain charitable, etc...
Ranyard, R; Charlton, J P; Williamson, J
2001-02-01
Alternative reference prices, either displayed in the environment (external) or recalled from memory (internal) are known to influence consumer judgments and decisions. In one line of previous research, internal reference prices have been defined in terms of general price expectations. However, Thaler (Marketing Science 4 (1985) 199; Journal of Behavioral Decision Making 12 (1999) 183) defined them as fair prices expected from specific types of seller. Using a Beer Pricing Task, he found that seller context had a substantial effect on willingness to pay, and concluded that this was due to specific internal reference prices evoked by specific contexts. In a think aloud study using the same task (N = 48), we found only a marginal effect of seller context. In a second study using the Beer Pricing Task and seven analogous ones (N = 144), general internal reference prices were estimated by asking people what they normally paid for various commodities. Both general internal reference prices and seller context influenced willingness to pay, although the effect of the latter was again rather small. We conclude that general internal reference prices have a greater impact in these scenarios than specific ones, because of the lower cognitive load involved in their storage and retrieval.
Killion, Chery M
2007-01-01
A nurse anthropologist with a background in international collaborations attended Project LEAD for two years, which enabled her to continue to serve as an advocate for the mentally ill in Belize. The anthropologist collaborated with a psychiatrist from Belize to develop a cross-cultural, cross-discipline publication, "Mental Health in Belize: A National Priority, " which highlights the work of psychiatric nurse practitioners in the country. The researcher learned to collaborate with her peer in Belize through face to face discussions and e-mail and overcame technological difficulties and cultural barriers to produce an international publication. Project LEAD gave the author a sense of self-discovery and self-knowledge, reinforced core values, and developed a frame of reference for leadership. The author also benefited from discussions by local, national, and international leaders on leadership in terms of its key components, contexts, challenges, triumphs, and styles.
The reference individual of radiation protection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerman, K.F.; Cristy, M.
1995-12-31
The 70-kg {open_quotes}standard man{close_quotes} representing a typical Western adult male has been used in physiological models since at least the 1920s. In 1949 at the Chalk River conference, health physicists from the U.S., UK, and Canada agreed on the concept of a standard man to facilitate comparison of internal dose estimates. The 70-kg standard man included specifications of the masses of 25 organs and tissues, total body content of 15 elements, total water intake and output, water content of the body, and some anatomical and physiological data for the respiratory and gastrointestinal tracts. In 1959, in its Publication 2{sup 2}more » on permissible doses for internal radiation the International Commission on Radiological Protection (ICRP) modified standard man. In 1963 the ICRP established a task group to revise and extend the standard man concept. The name was changed later to Reference Man and the task group`s work was published in 1975 as ICRP Publication 23{sup 3}. Publication 23 similar to Publication 2, updates and documents the sources of the data. Data on women, children, and fetuses were also collected, where available, but these data were limited primarily to anatomical data and only a few reference values were established for these groups. Information assembled during the course of the effort on the Reference Man report was used at Oak Ridge National Laboratory (ORNL) to construct a mathematical representation of the body (a phantom) that was suitable for use with Monte Carlo methods in the calculation of organ doses. That effort was undertaken to improve estimates of dose from photon-emitting radionuclides residing within organs, so-called internal emitters. The phantom, although updated throughout the years, remains today as the basis for organ dose estimates in nuclear medicine and radiation protection and underlies the radiation risk data derived from the epidemiologic studies of the atomic bomb survivors of Hiroshima and Nagasaki.« less
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-03-26
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-01-01
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800
Jiang, Lingxi; Yang, Litao; Zhang, Haibo; Guo, Jinchao; Mazzara, Marco; Van den Eede, Guy; Zhang, Dabing
2009-05-13
One rice ( Oryza sativa ) gene, sucrose phosphate synthase (SPS), has been proven to be a suitable endogenous reference gene for genetically modified (GM) rice detection in a previous study. Herein are the reported results of an international collaborative ring trial for validation of the SPS gene as an endogenous reference gene and its optimized qualitative and quantitative polymerase chain reaction (PCR) systems. A total of 12 genetically modified organism (GMO) detection laboratories from seven countries participated in the ring trial and returned their results. The validated results confirmed the species specificity of the method through testing 10 plant genomic DNAs, low heterogeneity, and a stable single-copy number of the rice SPS gene among 7 indica varieties and 5 japonica varieties. The SPS qualitative PCR assay was validated with a limit of detection (LOD) of 0.1%, which corresponded to about 230 copies of haploid rice genomic DNA, while the limit of quantification (LOQ) for the quantitative PCR system was about 23 copies of haploid rice genomic DNA, with acceptable PCR efficiency and linearity. Furthermore, the bias between the test and true values of eight blind samples ranged from 5.22 to 26.53%. Thus, we believe that the SPS gene is suitable for use as an endogenous reference gene for the identification and quantification of GM rice and its derivates.
Enhanced pid vs model predictive control applied to bldc motor
NASA Astrophysics Data System (ADS)
Gaya, M. S.; Muhammad, Auwal; Aliyu Abdulkadir, Rabiu; Salim, S. N. S.; Madugu, I. S.; Tijjani, Aminu; Aminu Yusuf, Lukman; Dauda Umar, Ibrahim; Khairi, M. T. M.
2018-01-01
BrushLess Direct Current (BLDC) motor is a multivariable and highly complex nonlinear system. Variation of internal parameter values with environment or reference signal increases the difficulty in controlling the BLDC effectively. Advanced control strategies (like model predictive control) often have to be integrated to satisfy the control desires. Enhancing or proper tuning of a conventional algorithm results in achieving the desired performance. This paper presents a performance comparison of Enhanced PID and Model Predictive Control (MPC) applied to brushless direct current motor. The simulation results demonstrated that the PSO-PID is slightly better than the PID and MPC in tracking the trajectory of the reference signal. The proposed scheme could be useful algorithms for the system.
Communications/Navigation Outage Forecasting System (C/NOFS)
2010-02-21
al., 2002]. They are also lower than values predicted by the International Reference Iono- sphere ( IRI ) model [Gulyaeva and Titheridge, 2006] run for...based on the IRI model or other observations. At present no mechanism has been proposed which accounts for the basic formation of BPDs or their...funding by the DMSP program office. We thank J. Retterer for the IRI model results. This research was supported by Air Force Office of Scientific Research
Crosstalk: The Journal of Defense Software Engineering. Volume 22, Number 3
2009-04-01
international standard for information security management systems like ISO /IEC 27001 :2005 [1] existed. Since that time, the organization has developed control...of ISO /IEC 27001 and the desire to make decisions based on business value and risk has prompted Ford’s IT Security and Controls organi- zation to begin...their conventional application security operation.u References 1. ISO /IEC 27001 :2005. “Information Technology – Security Techniques – Information
2007-11-01
overshadowed by an ideological confrontation of the two social value systems in the opposing coalitions, commonly referred to as the Cold War. It is possible...economic, social , political, and ideological national systems and foreign- policy preferences. The two superpowers’ military confrontation—a...svr.gov.ru. 12 Romashkina, N.P. Severokoreiskaia iadernaia problema : domysly i real’nost’. (The North Korean Nuclear Problem: Theories and Reality). Vol
[Pharmacovigilance center --internal medicine interactions: A useful diagnostic tool].
Rochoy, M; Gautier, S; Bordet, R; Caron, J; Launay, D; Hachulla, E; Hatron, P-Y; Lambert, M
2015-08-01
Patients hospitalized in internal medicine often have unexplained clinical symptoms for which a drug origin can be considered. The prevalence of patients hospitalized for iatrogenic is estimated between 4-22%. We wanted to evaluate the diagnostic value of the regional center of pharmacovigilance to identify or confirm an iatrogenic disease in the department of internal medicine of Lille and characterize factors associated with drug-related side effect. This is a single-center prospective diagnostic study. We included all subsequent requests from the department of internal medicine with the Nord-Pas-de-Calais regional pharmacovigilance center between 2010 and 2012. The opinion of the regional pharmacovigilance centre was held on the record of the adverse drug reaction in the national pharmacovigilance database and analyzed according to the conclusion of iatrogenic used by clinicians in internal medicine (reference diagnosis) with a follow-up to June 2013. The variables relating to the patient, medication and adverse events were analyzed by binary logistic regression. We analyzed 160 contacts: 118 concordant cases, 38 false-positives (drug-related side effect retained by the regional pharmacovigilance center only), 4 false negatives. Registration in the national pharmacovigilance database had a sensitivity of 96% (95% CI [0.92 to 0.99]), a specificity of 46% (95% CI [0.38 to 0.53]), a value positive predictive of 69% (95% CI [0.62 to 0.76]), a negative predictive value of 89% (95% CI [0.84 to 0.94]) and a negative likelihood ratio of 0.1. False-positive had chronological and semiological accountabilities questionable (adjusted RR=2.1, 95% CI [1.2 to 2.8]). In our study, the regional pharmacovigilance center confirms the clinician's suspicion of drug-related side effects and helps to exclude drug-induced with a high negative predictive value. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Griffin, M
2004-01-01
In 2002, the Parliament and Commission of the European Community agreed "minimum health and safety requirements" for the exposure of workers to the risks arising from vibration. The Directive defines qualitative requirements and also quantitative requirements in the form of "exposure action values" and "exposure limit values". The quantitative guidance is based on, but appears to conflict with, the guidance in International Standards for hand-transmitted vibration (ISO 5349) and whole-body vibration (ISO 2631). There is a large internal inconsistency within the Directive for short duration exposures to whole-body vibration: the two alternative methods give very different values. It would appear prudent to base actions on the qualitative guidance (i.e. reducing risk to a minimum) and only refer to the quantitative guidance where there is no other reasonable basis for the identification of risk (i.e. similar exposures are not a suspected cause of injury). Health surveillance and other precautions will be appropriate wherever there is reason to suspect a risk and will not be restricted to conditions where the exposure action value is exceeded. PMID:15090658
On the status of IAEA delta-13C stable isotope reference materials.
NASA Astrophysics Data System (ADS)
Assonov, Sergey; Groening, Manfred; Fajgelj, Ales
2016-04-01
For practical reasons all isotope measurements are performed on relative scales realized through the use of international, scale-defining primary standards. In fact these standards were materials (artefacts, similar to prototypes of meter and kg) selected based on their properties. The VPDB delta-13C scale is realised via two highest-level reference materials NBS19 and LSVEC, the first defining the scale and the second aimed to normalise lab-to-lab calibrations. These two reference materials (RMs) have been maintained and distributed by IAEA and NIST. The priority task is to maintain these primary RMs at the required uncertainty level, thus ensuring the long-term scale consistency. The second task is to introduce replacements when needed (currently for exhausted NBS19, work in progress). The next is to produce a family of lower level RMs (secondary, tertiary) addressing needs of various applications (with different delta values, in different physical-chemical forms) and their needs for the uncertainty; these RMs should be traceable to the highest level RMs. Presently three is a need for a range of RMs addressing existing and newly emerging analytical techniques (e.g. optical isotopic analysers) in form of calibrated CO2 gases with different delta-13C values. All that implies creating a family of delta-13C stable isotope reference materials. Presently IAEA works on replacement for NBS19 and planning new RMs. Besides, we found that LSVEC (introduced as second anchor for the VPDB scale in 2006) demonstrate a considerable scatter of its delta-13C value which implies a potential bias of the property value and increased value uncertainty which may conflict with uncertainty requirements for atmospheric monitoring. That is not compatible with the status of LSVEC, and therefore it should be replaced as soon as possible. The presentation will give an overview of the current status, the strategic plan of developments and the near future steps.
26 CFR 1.691(f)-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross reference. 1.691(f)-1 Section 1.691(f)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Income in Respect of Decedents § 1.691(f)-1 Cross reference. See section 753 and the...
Ho, Ming-Jung; Abbas, Joan; Ahn, Ducksun; Lai, Chi-Wan; Nara, Nobuo; Shaw, Kevin
2017-12-01
In an age of globalized medical education, medical school accreditation has been hailed as an approach to external quality assurance. However, accreditation standards can vary widely across national contexts. To achieve recognition by the World Federation for Medical Education (WFME), national accrediting bodies must develop standards suitable for both local contexts and international recognition. This study framed this issue in terms of "glocalization" and aimed to shine light on this complicated multistakeholder process by exploring accreditation in Taiwan, South Korea, and Japan. This study employed a comparative case-study design, examining the national standards that three accreditation bodies in East Asia developed using international reference standards. In 2015-2016, the authors conducted document analysis of the English versions of the standards to identify the differences between the national and international reference standards as well as how and why external standards were adapted. Each country's accreditation body sought to balance local needs with global demands. Each used external standards as a template (e.g., Liaison Committee on Medical Education, General Medical Council, or WFME standards) and either revised (Taiwan, South Korea) or annotated (Japan) the standards to fit the local context. Four categories of differences emerged to account for how and why national standards departed from external references: structural, regulatory, developmental, and aspirational. These countries' glocalization of medical accreditation standards serve as examples for others seeking to bring their accreditation practices in line with global standards while ensuring that local values and societal needs are given adequate consideration.
Lejarraga, Horacio; del Pino, Mariana; Fano, Virginia; Caino, Silvia; Cole, Timothy J
2009-04-01
Argentine growth references have been widely used by paediatricians in the country for the last 20 years. Two main difficulties were detected during this period: the lack of data on breast-fed children in the first months of age, and problems in the calculation of "z" scores. On these basis, local data on weight and height during the first two years of life were replaced by data from the longitudinal international study recently carried out by WHO. L, M and S values were obtained from the original percentile data for ages 2 to maturity, and smoothed with cubic splines. Selected percentiles for weight and height from birth to maturity were then re-calculated using LMS values. Charts were designed in two formats: birth to maturity and birth to 6.0 years. Now, users can calculate "z" scores automatically at the new site provided by the Department of Growth and Development, Hospital Garrahan, which enables the use of the LMS growth programme. We have also incorporated into the new charts, percentiles of the age of attaining menarche and Tanner s stage II of breast, genitalia and pubic hair for Argentine children. We think the new references represent an improvement in the assessment of growth in our country.
Physical profile of elite young motorcyclists.
Sánchez-Muñoz, C; Rodríguez, M A; Casimiro-Andújar, A J; Ortega, F B; Mateo-March, M; Zabala, M
2011-10-01
The aim of the study was to describe anthropometric and physical characteristics of elite young road-race motorcyclists (MC). 27 riders (15.6±1.1 years, 54.6±6.9 kg, 166.9±6.7 cm) competing at international elite level participated in this study. Anthropometric variables, hand grip and lumbar isometric strength, and lower-body muscular strength were measured. Comparisons of the MC and a reference group of Spanish physically active adolescents (16.0±0.6 years) showed that the riders were significantly lighter (-12.5 kg), and smaller (-4.7 cm). Riders also had significantly lower values for almost all skinfolds, and for all the measured girths (except forearm) than the reference group. Motorcyclists showed significantly less percent body fat (%BF) and higher muscle mass, and differences were observed for somatotype components compared to the reference group, except for the ectomorphy. Somatotype could be defined as mesomorphic-ectomorph (2.5-4.4-3.7). Mean (±SD) values of all riders were 34.8±5.0 cm for vertical jump height, 402.1±74.5 N for the right hand and 370.7±77.5 N for the left hand strengths, and 120.6±19.3 kg for lumbar isometric strength, respectively. Results demonstrate that MC are small and light, with lower body mass index, skinfolds, girth and breadth dimensions, and %BF than a reference group and other athletes, with high values of hand grip and lumbar isometric strength. © Georg Thieme Verlag KG Stuttgart · New York.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-07-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.
Propranolol reduces reference-dependence in intertemporal choice
Lempert, Karolina M.; Lackovic, Sandra F.; Tobe, Russell H.; Glimcher, Paul W.
2017-01-01
Abstract In intertemporal choices between immediate and delayed rewards, people tend to prefer immediate rewards, often even when the delayed reward is larger. This is known as temporal discounting. It has been proposed that this tendency emerges because immediate rewards are more emotionally arousing than delayed rewards. However, in our previous research, we found no evidence for this but instead found that arousal responses (indexed with pupil dilation) in intertemporal choice are context-dependent. Specifically, arousal tracks the subjective value of the more variable reward option in the paradigm, whether it is immediate or delayed. Nevertheless, people tend to choose the less variable option in the choice task. In other words, their choices are reference-dependent and depend on variance in their recent history of offers. This suggests that there may be a causal relationship between reference-dependent choice and arousal, which we investigate here by reducing arousal pharmacologically using propranolol. Here, we show that propranolol reduces reference-dependence, leading to choices that are less influenced by recent history and more internally consistent. PMID:28992268
Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B
1999-01-01
An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.
Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph
2007-01-01
The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
41 CFR 302-17.13 - Source references.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 4 2010-07-01 2010-07-01 false Source references. 302... references. The following references or publications have been used as source material for this part. (a...) Internal Revenue Service Publication 521, “Moving Expenses.” (c) Internal Revenue Service, Circular E...
26 CFR 1.642(a)(3)-3 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross reference. 1.642(a)(3)-3 Section 1.642(a)(3)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Estates, Trusts, and Beneficiaries § 1.642(a)(3)-3 Cross reference. See § 1.683-2(c...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2014 CFR
2014-07-01
... Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) OIL AND GAS EXTRACTION POINT...—Reference C16-C18 Internal Olefin Drilling Fluid Formulation The reference C16-C18 internal olefin drilling...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2012 CFR
2012-07-01
... Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) OIL AND GAS EXTRACTION POINT...—Reference C16-C18 Internal Olefin Drilling Fluid Formulation The reference C16-C18 internal olefin drilling...
40 CFR Appendix 8 to Subpart A of... - Reference C16-C18 Internal Olefin Drilling Fluid Formulation
Code of Federal Regulations, 2013 CFR
2013-07-01
... Drilling Fluid Formulation 8 Appendix 8 to Subpart A of Part 435 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) OIL AND GAS EXTRACTION POINT...—Reference C16-C18 Internal Olefin Drilling Fluid Formulation The reference C16-C18 internal olefin drilling...
NASA Astrophysics Data System (ADS)
Rabah, Mostafa; Elmewafey, Mahmoud; Farahan, Magda H.
2016-06-01
A geodetic control network is the wire-frame or the skeleton on which continuous and consistent mapping, Geographic Information Systems (GIS), and surveys are based. Traditionally, geodetic control points are established as permanent physical monuments placed in the ground and precisely marked, located, and documented. With the development of satellite surveying methods and their availability and high degree of accuracy, a geodetic control network could be established by using GNSS and referred to an international terrestrial reference frame used as a three-dimensional geocentric reference system for a country. Based on this concept, in 1992, the Egypt Survey Authority (ESA) established two networks, namely High Accuracy Reference Network (HARN) and the National Agricultural Cadastral Network (NACN). To transfer the International Terrestrial Reference Frame to the HARN, the HARN was connected with four IGS stations. The processing results were 1:10,000,000 (Order A) for HARN and 1:1,000,000 (Order B) for NACN relative network accuracy standard between stations defined in ITRF1994 Epoch1996. Since 1996, ESA did not perform any updating or maintaining works for these networks. To see how non-performing maintenance degrading the values of the HARN and NACN, the available HARN and NACN stations in the Nile Delta were observed. The Processing of the tested part was done by CSRS-PPP Service based on utilizing Precise Point Positioning "PPP" and Trimble Business Center "TBC". The study shows the feasibility of Precise Point Positioning in updating the absolute positioning of the HARN network and its role in updating the reference frame (ITRF). The study also confirmed the necessity of the absent role of datum maintenance of Egypt networks.
Baya Botti, A; Pérez-Cueto, F J A; Vasquez Monllor, P A; Kolsteren, P W
2010-01-01
Since no growth standards for adolescents exist and a single reference applicable everywhere is still in debate, it is recognized that the best reference should be derived from the growth pattern of the healthy population that will use it. In 2007 a study developed references for body mass index for 12th to 18th y Bolivian school adolescent (BAP. To compare nutritional status outcomes applying BMI references from the BAP, the Center for Disease Control and Prevention CDC 2000, the International Task Force (IOTF), and the 2007 WHO, to determine appropriateness of use in Bolivian adolescents. References were applied in 3306 adolescents, 45.0% male, 55% female, 12th to 18th y selected from a nationally representative sample. Main findings reveal that the CDC and the 2007 WHO underestimate underweight (p<0.001) and the three international references overestimate overweight (p<0.001) with variation between ages and gender. Bolivian health providers are advised to replace CDC, OITF and 2007 WHO references for the use of BAP in Bolivia which reflects its healthy adolescent population growth pattern. International references may lead to incorrect conclusions when applied on Bolivian adolescents. They could deflect efforts from population which need prompt intervention and mislead treatments and budget to unnecessary ones. We recommend validation of international references where appropriate until a standard is released.
Definition and Proposed Realization of the International Height Reference System (IHRS)
NASA Astrophysics Data System (ADS)
Ihde, Johannes; Sánchez, Laura; Barzaghi, Riccardo; Drewes, Hermann; Foerste, Christoph; Gruber, Thomas; Liebsch, Gunter; Marti, Urs; Pail, Roland; Sideris, Michael
2017-05-01
Studying, understanding and modelling global change require geodetic reference frames with an order of accuracy higher than the magnitude of the effects to be actually studied and with high consistency and reliability worldwide. The International Association of Geodesy, taking care of providing a precise geodetic infrastructure for monitoring the Earth system, promotes the implementation of an integrated global geodetic reference frame that provides a reliable frame for consistent analysis and modelling of global phenomena and processes affecting the Earth's gravity field, the Earth's surface geometry and the Earth's rotation. The definition, realization, maintenance and wide utilization of the International Terrestrial Reference System guarantee a globally unified geometric reference frame with an accuracy at the millimetre level. An equivalent high-precision global physical reference frame that supports the reliable description of changes in the Earth's gravity field (such as sea level variations, mass displacements, processes associated with geophysical fluids) is missing. This paper addresses the theoretical foundations supporting the implementation of such a physical reference surface in terms of an International Height Reference System and provides guidance for the coming activities required for the practical and sustainable realization of this system. Based on conceptual approaches of physical geodesy, the requirements for a unified global height reference system are derived. In accordance with the practice, its realization as the International Height Reference Frame is designed. Further steps for the implementation are also proposed.
Glycaemic index and glycaemic load values of commonly consumed foods in the United Arab Emirates.
Al Dhaheri, Ayesha S; Henry, C Jeyakumar K; Mohamad, Maysm N; Ohuma, Eric O; Ismail, Leila Cheikh; Al Meqbaali, Fatima T; Jarrar, Amjad H
2017-04-01
Glycaemic index (GI) and glycaemic load (GL) values of some commonly consumed foods in the United Arab Emirates were determined with an aim of adding these values to the existing international table of GI and GL values. In all, eighteen test foods categorised into breads (n 5), entrée dishes (n 3), main dishes (n 5) and sweet dishes (n 5) were tested. For each test food, at least fifteen healthy participants consumed 25 or 50 g available carbohydrate portions of a reference food (glucose), which was tested three times, and a test food after an overnight fast, was tested once, on separate occasions. Capillary blood samples were obtained by finger-prick and blood glucose was measured using clinical chemistry analyser. A fasting blood sample was obtained at baseline and before consumption of test foods. Additional blood samples were obtained at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI value of each test food was calculated as the percentage of the incremental area under the blood glucose curve (IAUC) for the test food of each participant divided by the average IAUC for the reference food of the same participant. The GI values of tested foods ranged from low (55 or less) to high (70 or more). The GI values of various breads and rice-containing dishes were comparable with previously published values. This study provides GI and GL values of previously untested traditional Emirati foods which could provide a useful guide on dietary recommendations for the Emirati population.
Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan
2015-10-01
An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.
Lim, Ji-Ae; Kwon, Ho-Jang; Ha, Mina; Kim, Ho; Oh, Se Young; Kim, Jeong Seon; Lee, Sang-Ah; Park, Jung-Duck; Hong, Young-Seoub; Sohn, Seok-Joon; Pyo, Heesoo; Park, Kyung Su; Lee, Kwang-Geun; Kim, Yong Dae; Jun, Sangil; Hwang, Myung Sil
2015-01-01
Objectives: This survey was designed to conduct the first nationwide dietary exposure assessment on hazardous substances including the intakes of functional food and herbal medicine. In this paper, we introduced the survey design and the results of the dietary exposure status and internal exposure levels of lead (Pb), cadmium (Cd), and mercury (Hg). Methods: We selected 4867 subjects of all ages throughout Korea. We conducted a food survey, dietary survey, biomonitoring, and health survey. Results: Pb and Cd were the highest (median value) in the seaweed (94.2 μg/kg for Pb; 594 μg/kg for Cd), and Hg was the highest in the fish (46.4 μg/kg). The dietary exposure level (median value) of Pb was 0.14 μg/kg body weight (bw)/d, 0.18 μg/kg bw/d for Cd, and 0.07 μg/kg bw/d for Hg. Those with a blood Pb level of less than 5.00 μg/dL (US Centers for Disease Control and Prevention, reference value for those 1 to 5 years of age) were 99.0% of all the subjects. Those with a blood Cd level with less than 0.30 μg/L (German Federal Environmental Agency, reference value for non-smoking children) were 24.5%. For those with a blood Hg level with less than 5.00 μg/L (human biomonitoring I, references value for children and adults, German Federal Environmental Agency) was 81.0 % of all the subjects. Conclusions: The main dietary exposure of heavy metals occurs through food consumed in a large quantity and high frequency. The blood Hg level and dietary exposure level of Hg were both higher than those in the European Union. PMID:26184046
Synchronization trigger control system for flow visualization
NASA Technical Reports Server (NTRS)
Chun, K. S.
1987-01-01
The use of cinematography or holographic interferometry for dynamic flow visualization in an internal combustion engine requires a control device that globally synchronizes camera and light source timing at a predefined shaft encoder angle. The device is capable of 0.35 deg resolution for rotational speeds of up to 73 240 rpm. This was achieved by implementing the shaft encoder signal addressed look-up table (LUT) and appropriate latches. The developed digital signal processing technique achieves 25 nsec of high speed triggering angle detection by using direct parallel bit comparison of the shaft encoder digital code with a simulated angle reference code, instead of using angle value comparison which involves more complicated computation steps. In order to establish synchronization to an AC reference signal whose magnitude is variant with the rotating speed, a dynamic peak followup synchronization technique has been devised. This method scrutinizes the reference signal and provides the right timing within 40 nsec. Two application examples are described.
The principles of quantification applied to in vivo proton MR spectroscopy.
Helms, Gunther
2008-08-01
Following the identification of metabolite signals in the in vivo MR spectrum, quantification is the procedure to estimate numerical values of their concentrations. The two essential steps are discussed in detail: analysis by fitting a model of prior knowledge, that is, the decomposition of the spectrum into the signals of singular metabolites; then, normalization of these signals to yield concentration estimates. Special attention is given to using the in vivo water signal as internal reference.
Lessons Learned: The Iran-Iraq War
1991-01-01
enemy in an ecstasy of religious exultation. Moreover, the Basij in particular did not have the training for such operations. The Basij were called up...international news media, to whom it seemed a brilliant stroke of strategy.31 In our view, Al Faw was a fluke. In fact, it was precisely the lucky... stroke that we referred to earlier in discussing the limitations of static defense. We believe that the Iranians seized Al Faw for its publicity value
2012-12-01
6 The term psychophysical refers to the link between physical stimulus and psychological changes. Rose McDermott, Risk Taking in International...Foreign Policy., Barbara Farnham, “Roosevelt and the Munich Crisis: Insights from Prospect Theory,” Political Psychology 13, no. 2 (1992)., Mark L. Haas...gains.170 Losses hurt worse from a psychological standpoint than gains feel good. Figure 9. Prospect Value Graph (From Jervis, 1992
NASA Astrophysics Data System (ADS)
Michotte, C.; Ratel, G.; Courte, S.; Sochorovà, J.; Auerbach, P.; Keightley, J.; Johansson, L.; Bakhshandeiar, E.; Cassette, P.; Moune, M.; Capogni, M.; De Felice, P.
2013-01-01
Since 2009, four national metrology institutes (NMI) have submitted four samples of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Cu-64. The values of the activity submitted were between about 3 MBq and 260 MBq. There are now five results in the BIPM.RI(II)-K1.Cu-64 comparison. A key comparison reference value (KCRV) has been calculated for the first time for this nuclide. The degrees of equivalence between each equivalent activity measured in the SIR and the KCRV have been calculated and the results are given in the form of a table. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S
2013-06-01
The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.
Changes in radiation dose with variations in human anatomy: moderately and severely obese adults.
Clark, Landon D; Stabin, Michael G; Fernald, Michael J; Brill, Aaron B
2010-06-01
The phantoms used in standardized dose assessment are based on a median (i.e., 50th percentile) individual of a large population, for example, adult males or females or children of a particular age. Here we describe phantoms that model instead the influence of obesity on specific absorbed fractions (SAFs) and dose factors in adults. The literature was reviewed to evaluate how individual organ sizes change with variations in body weight in mildly and severely obese adult men and women. On the basis of the literature evaluation, changes were made to our deformable reference adult male and female total-body models. Monte Carlo simulations of radiation transport were performed. SAFs for photons were generated for mildly and severely obese adults, and comparisons were made to the reference (50th) percentile SAF values. SAFs studied between the obese phantoms and the 50th percentile reference phantoms were not significantly different from the reference 50th percentile individual, with the exception of intestines irradiating some abdominal organs, because of an increase in separation between folds caused by an increase in mesenteric adipose deposits. Some low-energy values for certain organ pairs were different, possibly due only to the statistical variability of the data at these low energies. The effect of obesity on dose calculations for internal emitters is minor and may be neglected in the routine use of standardized dose estimates.
26 CFR 1.6851-3 - Furnishing of bond to insure payment; cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Furnishing of bond to insure payment; cross reference. 1.6851-3 Section 1.6851-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... Penalties § 1.6851-3 Furnishing of bond to insure payment; cross reference. See section 6863 and § 301.6863...
ERIC Educational Resources Information Center
Moller, Jens; Retelsdorf, Jan; Koller, Olaf; Marsh, Herb W.
2011-01-01
The reciprocal internal/external frame of reference model (RI/EM) combines the internal/external frame of reference model and the reciprocal effects model. The RI/EM predicts positive effects of mathematics and verbal achievement and academic self-concepts (ASC) on subsequent mathematics and verbal achievements and ASCs within domains and negative…
[Geographical distribution of the Serum creatinine reference values of healthy adults].
Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng
2016-11-20
To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.
Kostecka-Matyja, Marta; Fedorowicz, Anna; Bar-Andziak, Ewa; Bednarczuk, Tomasz; Buziak-Bereza, Monika; Dumnicka, Paulina; Górska, Maria; Krasnodębska, Małgorzata; Niedźwiedzka, Beata; Pach, Dorota; Ruchała, Marek; Siewko, Katarzyna; Solnica, Bogdan; Sowiński, Jerzy; Szelachowska, Małgorzata; Trofimiuk-Müldner, Małgorzata; Wachowiak-Ochmańska, Katarzyna; Hubalewska-Dydejczyk, Alicja
2017-04-01
The diagnosis and treatment of thyroid diseases in pregnant women remains a challenge. Various medical associations recommend establishing the reference intervals for thyroid hormones by a local laboratory. Considering differences within geophysical, socioeconomic conditions, and iodine prophylaxis in various populations, it is advisable to assess reference intervals for thyroid hormones specific to a region of residence. The objective was to assess trimester-specific reference intervals for TSH, fT 3 , and fT 4 for pregnant women in the Polish population. We conducted a prospective study in 4 centers representing different regions of Poland (Krakow, Warsaw, Poznan, and Bialystok). Our study included consecutive, healthy pregnant women (172 patients), with an age range of 27-47 years. All women had a negative history for thyroid diseases, normal thyroid peroxidase antibody levels, and proper iodine prophylaxis. All newborns had TSH levels in the appropriate reference range. Serum TSH, fT 3 , fT 4 , and thyroid-peroxidase antibodies were measured in each trimester. The reference intervals were calculated using the percentile method, as recommended by the International Federation of Clinical Chemistry. The reference values calculated were 0.009-3.177, 0.05-3.442, and 0.11-3.53 mIU/L for TSH; 3.63-6.55, 3.29-5.45, and 3.1-5.37 pmol/L for fT 3 ; and 11.99-21.89, 10.46-16.67, and 8.96-17.23 pmol/L for fT 4 in consecutive trimesters of pregnancy. Reference intervals for pregnant women when compared to the general population showed a lower concentration of TSH in every trimester of pregnancy and lower fT 4 in the 2nd and 3rd trimesters. Using appropriate trimester-specific reference intervals may improve care of pregnant women by preventing misdiagnosis and inadequate treatment.
76 FR 50414 - International Mail Manual; Incorporation by Reference
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-15
... POSTAL SERVICE 39 CFR Part 20 International Mail Manual; Incorporation by Reference AGENCY: Postal... Standards of the United States Postal Service, International Mail Manual (IMM[supreg]) dated April 17, 2011.... SUPPLEMENTARY INFORMATION: The International Mail Manual was issued on April 17, 2011, and was updated with...
75 FR 34017 - International Mail Manual; Incorporation by Reference
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-16
... POSTAL SERVICE 39 CFR Part 20 International Mail Manual; Incorporation by Reference AGENCY: Postal... Mailing Standards of the United States Postal Service, International Mail Manual (IMM[supreg]) and its..., (202) 268-3789. SUPPLEMENTARY INFORMATION: Issue 36 of the International Mail Manual was issued on May...
Chuntarut, A; Tientadakul, P; Wongkrajang, P
2016-06-01
The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.
Chambers, Brian; Chambers, Jayne; Churilov, Leonid; Cameron, Heather; Macdonell, Richard
2014-09-01
We evaluated internal jugular vein and vertebral vein volume flow using ultrasound, in patients with clinically isolated syndrome or mild multiple sclerosis and controls, to determine whether volume flow was different between the two groups. In patients and controls, internal jugular vein volume flow increased from superior to inferior segments, consistent with recruitment from collateral veins. Internal jugular vein and vertebral vein volume flow were greater on the right in supine and sitting positions. Internal jugular vein volume flow was higher in the supine posture. Vertebral vein volume flow was higher in the sitting posture. Regression analyses of cube root transformed volume flow data, adjusted for supine/sitting, right/left and internal jugular vein/vertebral vein, revealed no significant difference in volume flow in patients compared to controls. Our findings further refute the concept of venous obstruction as a causal factor in the pathogenesis of multiple sclerosis. Control volume flow data may provide useful normative reference values. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
How Should Blood Glucose Meter System Analytical Performance Be Assessed?
Simmons, David A
2015-08-31
Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.
Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E
2008-05-23
Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.
77 FR 64724 - International Mail Manual; Incorporation by Reference
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... POSTAL SERVICE 39 CFR Part 20 International Mail Manual; Incorporation by Reference AGENCY: Postal... Standards of the United States Postal Service, International Mail Manual (IMM[supreg]) dated June 24, 2012... International Mail Manual was issued on June 24, 2012, and was updated with postal bulletin revisions through...
ERIC Educational Resources Information Center
Parker, Philip D.; Marsh, Herbert W.; Ludtke, Oliver; Trautwein, Ulrich
2013-01-01
The internal/external frame of reference and the big-fish-little-pond effect are two major models of academic self-concept formation which have considerable theoretical and empirical support. Integrating the domain specific and compensatory processes of the internal/external frame of reference model with the big-fish-little-pond effect suggests a…
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
Precise Clock Solutions Using Carrier Phase from GPS Receivers in the International GPS Service
NASA Technical Reports Server (NTRS)
Zumberge, J. F.; Jefferson, D. C.; Stowers, D. A.; Tjoelker, R. L.; Young, L. E.
1999-01-01
As one of its activities as an Analysis Center in the International GPS Service (IGS), the Jet Propulsion Laboratory (JPL) uses data from a globally distributed network of geodetic-quality GPS receivers to estimate precise clock solutions, relative to a chosen reference, for both the GPS satellites and GPS receiver internal clocks, every day. The GPS constellation and ground network provide geometrical strength resulting in formal errors of about 100 p sec for these estimates. Some of the receivers in the global IGS network contain high quality frequency references, such as hydrogen masers. The clock solutions for such receivers are smooth at the 20-p sec level on time scales of a few minutes. There are occasional (daily to weekly) shifts at the microsec level, symptomatic of receiver resets, and 200-p sec-level discontinuities at midnight due to 1-day processing boundaries. Relative clock solutions among 22 IGS sites proposed as "fiducial" in the IGS/BIPM pilot project have been examined over a recent 4-week period. This allows a quantitative measure of receiver reset frequency as a function of site. For days and-sites without resets, the Allan deviation of the relative clock solutions is also computed for subdaily values of tau..
Complete internal audit of a mammography service in a reference institution for breast imaging.
Badan, Gustavo Machado; Roveda Júnior, Décio; Ferreira, Carlos Alberto Pecci; de Noronha Junior, Ozeas Alves
2014-01-01
Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS(®), in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.
Determination of uncertainties associated to the in vivo measurement of iodine-131 in the thyroid.
Dantas, B M; Lima, F F; Dantas, A L; Lucena, E A; Gontijo, R M G; Carvalho, C B; Hazin, C
2016-07-01
Intakes of radionuclides can be estimated through in vivo measurements, and the uncertainties associated to the measured activities should be clearly stated in monitoring program reports. This study aims to evaluate the uncertainties of in vivo monitoring of iodine 131 in the thyroid. The reference values for high-energy photons are based on the IDEAS Guide. Measurements were performed at the In Vivo Monitoring Laboratory of the Institute of Radiation Protection and Dosimetry (IRD) and at the Internal Dosimetry Laboratory of the Regional Center of Nuclear Sciences (CRCN-NE). In both institutions, the experiment was performed using a NaI(Tl) 3''3″ scintillation detector and a neck-thyroid phantom. Scattering factors were calculated and compared in different counting geometries. The results show that the technique produces reproducibility equivalent to the values suggested in the IDEAS Guide and measurement uncertainties is comparable to international quality standards for this type of in vivo monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pfau, Doreen B; Krumova, Elena K; Treede, Rolf-Detlef; Baron, Ralf; Toelle, Thomas; Birklein, Frank; Eich, Wolfgang; Geber, Christian; Gerhardt, Andreas; Weiss, Thomas; Magerl, Walter; Maier, Christoph
2014-05-01
Age- and gender-matched reference values are essential for the clinical use of quantitative sensory testing (QST). To extend the standard test sites for QST-according to the German Research Network on Neuropathic Pain-to the trunk, we collected QST profiles on the back in 162 healthy subjects. Sensory profiles for standard test sites were within normal interlaboratory differences. QST revealed lower sensitivity on the upper back than the hand, and higher sensitivity on the lower back than the foot, but no systematic differences between these trunk sites. Age effects were significant for most parameters. Females exhibited lower pressure pain thresholds (PPT) than males, which was the only significant gender difference. Values outside the 95% confidence interval of healthy subjects (considered abnormal) required temperature changes of >3.3-8.2 °C for thermal detection. For cold pain thresholds, confidence intervals extended mostly beyond safety cutoffs, hence only relative reference data (left-right differences, hand-trunk differences) were sufficiently sensitive. For mechanical detection and pain thresholds, left-right differences were 1.5-2.3 times more sensitive than absolute reference data. The most sensitive parameter was PPT, where already side-to-side differences >35% were abnormal. Compared to trunk reference data, patients with postherpetic neuralgia exhibited thermal and tactile deficits and dynamic mechanical allodynia, mostly without reduced mechanical pain thresholds. This pattern deviates from other types of neuropathic pain. QST reference data for the trunk will also be useful for patients with postthoracotomy pain or chronic back pain. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
The International Symposium on Equatorial Aeronomy (10th) Held in Antalya, Turkey on May 17-23, 2000
2000-10-23
Paulo - FAPESP, and the Programa de Nicleos de Excelencia - PRONEX. Nu- merical values for the model tides were taken from the GSWM homepage at http...FAPESP, and the Programa de Nilcleos de Excel~ncia-PRONEX. References Batista, P. P., B. R. Clemesha, I. S. Batista and D. M. Simonich, Characteristics...based on M. J. Taylor, H. Takahashi, D. Gobbi, and A. Chemical and Dynamical Processes, Tarun Kumar F. de Medeiros. Pant and R. SRIDHARAN. 13. 17:30-17
The Geochemical Databases GEOROC and GeoReM - What's New?
NASA Astrophysics Data System (ADS)
Sarbas, B.; Jochum, K. P.; Nohl, U.; Weis, U.
2017-12-01
The geochemical databases GEOROC (http: georoc.mpch-mainz.gwdg.de) and GeoReM (http: georem.mpch-mainz.gwdg.de) are maintained by the Max Planck Institute for Chemistry in Mainz, Germany. Both online databases became crucial tools for geoscientists from different research areas. They are regularly upgraded by new tools and new data from recent publications obtained from a wide range of international journals. GEOROC is a collection of published analyses of volcanic rocks and mantle xenoliths. Since recently, data for plutonic rocks are added. The analyses include major and trace element concentrations, radiogenic and non-radiogenic isotope ratios as well as analytical ages for whole rocks, glasses, minerals and inclusions. Samples come from eleven geological settings and span the whole geological age scale from Archean to Recent. Metadata include, among others, geographic location, rock class and rock type, geological age, degree of alteration, analytical method, laboratory, and reference. The GEOROC web page allows selection of samples by geological setting, geography, chemical criteria, rock or sample name, and bibliographic criteria. In addition, it provides a large number of precompiled files for individual locations, minerals and rock classes. GeoReM is a database collecting information about reference materials of geological and environmental interest, such as rock powders, synthetic and natural glasses as well as mineral, isotopic, biological, river water and seawater reference materials. It contains published data and compilation values (major and trace element concentrations and mass fractions, radiogenic and stable isotope ratios). Metadata comprise, among others, uncertainty, analytical method and laboratory. Reference materials are important for calibration, method validation, quality control and to establish metrological traceability. GeoReM offers six different search strategies: samples or materials (published values), samples (GeoReM preferred values), chemical criteria, chemical criteria based on bibliography, bibliography, as well as methods and institutions.
Calculation of local skin doses with ICRP adult mesh-type reference computational phantoms
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Han, Haegin; Choi, Chansoo; Nguyen, Thang Tat; Lee, Hanjin; Shin, Bangho; Kim, Chan Hyeong; Han, Min Cheol
2018-01-01
Recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) developed new mesh-type reference computational phantoms (MRCPs) for adult males and females in order to address the limitations of the current voxel-type reference phantoms described in ICRP Publication 110 due to their limited voxel resolutions and the nature of the voxel geometry. One of the substantial advantages of the MRCPs over the ICRP-110 reference phantoms is the inclusion of a 50-μm-thick radiosensitive skin basal-cell layer; however, a methodology for calculating the local skin dose (LSD), i.e., the maximum dose to the basal layer averaged over a 1-cm2 area, has yet to be developed. In the present study, a dedicated program for the LSD calculation with the MRCPs was developed based on the mean shift algorithm and the Geant4 Monte Carlo code. The developed program was used to calculate local skin dose coefficients (LSDCs) for electrons and alpha particles, which were then compared with the values given in ICRP Publication 116 that were produced with a simple tissue-equivalent cube model. The results of the present study show that the LSDCs of the MRCPs are generally in good agreement with the ICRP-116 values for alpha particles, but for electrons, significant differences are found at energies higher than 0.15 MeV. The LSDCs of the MRCPs are greater than the ICRP-116 values by as much as 2.7 times at 10 MeV, which is due mainly to the different curvature between realistic MRCPs ( i.e., curved) and the simple cube model ( i.e., flat).
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-01-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449
NASA Astrophysics Data System (ADS)
Fey, A. L.; Gordon, D.; Jacobs, C. S.; Ma, C.; Gaume, R. A.; Arias, E. F.; Bianco, G.; Boboltz, D. A.; Böckmann, S.; Bolotin, S.; Charlot, P.; Collioud, A.; Engelhardt, G.; Gipson, J.; Gontier, A.-M.; Heinkelmann, R.; Kurdubov, S.; Lambert, S.; Lytvyn, S.; MacMillan, D. S.; Malkin, Z.; Nothnagel, A.; Ojha, R.; Skurikhina, E.; Sokolova, J.; Souchay, J.; Sovers, O. J.; Tesmer, V.; Titov, O.; Wang, G.; Zharov, V.
2015-08-01
We present the second realization of the International Celestial Reference Frame (ICRF2) at radio wavelengths using nearly 30 years of Very Long Baseline Interferometry observations. ICRF2 contains precise positions of 3414 compact radio astronomical objects and has a positional noise floor of ∼40 μas and a directional stability of the frame axes of ∼10 μas. A set of 295 new “defining” sources was selected on the basis of positional stability and the lack of extensive intrinsic source structure. The positional stability of these 295 defining sources and their more uniform sky distribution eliminates the two greatest weaknesses of the first realization of the International Celestial Reference Frame (ICRF1). Alignment of ICRF2 with the International Celestial Reference System was made using 138 positionally stable sources common to both ICRF2 and ICRF1. The resulting ICRF2 was adopted by the International Astronomical Union as the new fundamental celestial reference frame, replacing ICRF1 as of 2010 January 1.
Accurate determination of brain metabolite concentrations using ERETIC as external reference.
Zoelch, Niklaus; Hock, Andreas; Heinzer-Schweizer, Susanne; Avdievitch, Nikolai; Henning, Anke
2017-08-01
Magnetic Resonance Spectroscopy (MRS) can provide in vivo metabolite concentrations in standard concentration units if a reliable reference signal is available. For 1 H MRS in the human brain, typically the signal from the tissue water is used as the (internal) reference signal. However, a concentration determination based on the tissue water signal most often requires a reliable estimate of the water concentration present in the investigated tissue. Especially in clinically interesting cases, this estimation might be difficult. To avoid assumptions about the water in the investigated tissue, the Electric REference To access In vivo Concentrations (ERETIC) method has been proposed. In this approach, the metabolite signal is compared with a reference signal acquired in a phantom and potential coil-loading differences are corrected using a synthetic reference signal. The aim of this study, conducted with a transceiver quadrature head coil, was to increase the accuracy of the ERETIC method by correcting the influence of spatial B 1 inhomogeneities and to simplify the quantification with ERETIC by incorporating an automatic phase correction for the ERETIC signal. Transmit field ( B1+) differences are minimized with a volume-selective power optimization, whereas reception sensitivity changes are corrected using contrast-minimized images of the brain and by adapting the voxel location in the phantom measurement closely to the position measured in vivo. By applying the proposed B 1 correction scheme, the mean metabolite concentrations determined with ERETIC in 21 healthy subjects at three different positions agree with concentrations derived with the tissue water signal as reference. In addition, brain water concentrations determined with ERETIC were in agreement with estimations derived using tissue segmentation and literature values for relative water densities. Based on the results, the ERETIC method presented here is a valid tool to derive in vivo metabolite concentration, with potential advantages compared with internal water referencing in diseased tissue. Copyright © 2017 John Wiley & Sons, Ltd.
Sert, Şenol
2013-07-01
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal standard for the internal standardization method. The robust conditions were evaluated using applied radiofrequency power, nebulizer argon gas flow rate, and sample uptake flow rate by considering the intensity ratio of the Mg(II) 280.270 nm and Mg(I) 285.213 nm lines. Analytical characterization of method was assessed by limit of detection and relative standard deviation values. The certificated reference soil sample IAEA S-8 was analyzed, and the uranium determination at 367.007 nm with internal standardization using Sm at 359.260 nm has been shown to improve accuracy compared with other methods. The developed method was used for real uranium ore sample analysis.
Tong, Qing; Chen, Baorong; Zhang, Rui; Zuo, Chang
Variation in clinical enzyme analysis, particularly across different measuring systems and laboratories, represents a critical but long-lasting problem in diagnosis. Calibrators with traceability and commutability are imminently needed to harmonize analysis in laboratory medicine. Fresh frozen human serum pools were assigned values for alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyltransferase (GGT), creatine kinase (CK) and lactate dehydrogenase (LDH) by six laboratories with established International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures. These serum pools were then used across 76 laboratories as a calibrator in the analysis of five enzymes. Bias and imprecision in the measurement of the five enzymes tested were significantly reduced by using the value-assigned serum in analytical systems with open and single-point calibration. The median (interquartile range) of the relative biases of ALT, AST, GGT, CK and LDH were 2.0% (0.6-3.4%), 0.8% (-0.8-2.3%), 1.0% (-0.5-2.0%), 0.2% (-0.3-1.0%) and 0.2% (-0.9-1.1%), respectively. Before calibration, the interlaboratory coefficients of variation (CVs) in the analysis of patient serum samples were 8.0-8.2%, 7.3-8.5%, 8.1-8.7%, 5.1-5.9% and 5.8-6.4% for ALT, AST, GGT, CK and LDH, respectively; after calibration, the CVs decreased to 2.7-3.3%, 3.0-3.6%, 1.6-2.1%, 1.8-1.9% and 3.3-3.5%, respectively. The results suggest that the use of fresh frozen serum pools significantly improved the comparability of test results in analytical systems with open and single-point calibration.
Olsen, Timothy W.
2008-01-01
Purpose To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Methods Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Results Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. Conclusions The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores. PMID:19277247
Riondato, J; Vanhaecke, F; Moens, L; Dams, R
2001-07-01
In the framework of an international certification campaign, sector-field inductively coupled plasma mass spectrometry (sector-field ICP-MS) was used for the accurate determination of the rare earth elements in five candidate reference materials: aquatic plant, calcareous soil, mussel tissue, river sediment, and tuna muscle. All samples were taken into solution by use of microwave-assisted or mixed microwave-assisted / open beaker acid digestion. Subsequently, the samples were appropriately diluted and subjected to ICP-MS analysis. Except for Sc, all the elements involved were determined at low mass resolution (R = 300). For Sc, application of a higher resolution setting (R = 3,000) was required to separate the analyte signal from those of several molecular ions which gave rise to spectral overlap at low mass resolution. Some of the heavier REE can also suffer from spectral overlap attributed to the occurrence of oxide ions (MO+) of the lighter REE and Ba. This spectral overlap could be successfully overcome by mathematical correction. Matrix effects were overcome by use of two carefully selected internal standards, such that external calibration could be used. On each occasion, a geological reference material was analyzed as a quality-control sample and the reliability of all results obtained was additionally checked by means of chondrite normalization. For tuna muscle the content of all REE was below the limit of detection. For calcareous soil and river sediment, low to sub microg g(-1) values were observed, whereas the REE content of aquatic plant and mussel tissue was considerably lower (low to sub ng g(-1)). Overall, the results obtained were in excellent agreement with the average values, calculated on the basis of all "accepted" values, obtained in different laboratories using different techniques.
Training in Geoethics: Shared Values in Serving Society
NASA Astrophysics Data System (ADS)
Peppoloni, S.; Di Capua, G.
2014-12-01
Geosciences have evident repercussions on society. Geoscientists possess knowledge and skills to investigate, manage and intervene on the Geosphere, and this implies ethical obligations. So, the adoption of ethical principles and standards is crucial if geoscientists want to best serve the public. Their ethical responsibility requires a more active role in interacting with society, by giving people valuable contexts that inform the need for sustainable development, and perspectives that reveal essential and delicate balances of natural systems that impact humanity. Geoethics consists of research and reflection on those values upon which to base appropriate behaviour and practices where human activities intersect the Geosphere, and should become an essential point of reference in geoscientists' curricula. Acting in this direction implies the awareness by the geological community of its ethical commitments and the necessity to train new generations of geoscientists that in the future will be able to transfer to society not only practical aspects of geological knowledge, but also a new way to understand our planet. The IAPG - International Association for Promoting Geoethics (www.iapg.geoethics.org) was born to build a new awareness in the scientific community. It aims at joining forces of geoscientists all over the world, through creation of an international, multidisciplinary and scientific platform for discussing ethical problems and dilemmas in Earth Sciences, for strengthening the research base on Geoethics through scientific publications and conferences. Its main goal is to give a new cultural framework of reference, in which to develop effective training tools, in order to sensitize young geoscientists on ethical and social issues related to their future work, starting from the definition of shared values within the scientific community. This work provides an overview on the IAPG goals, activities and ongoing initiatives.
Olsen, Timothy W
2008-01-01
To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores.
Reference Values for Cardiorespiratory Fitness and Incidence of Type 2 Diabetes
Kawakami, Ryoko; Sawada, Susumu S.; Matsushita, Munehiro; Okamoto, Takashi; Tsukamoto, Koji; Higuchi, Mitsuru; Miyachi, Motohiko
2014-01-01
Background In “Physical Activity Reference for Health Promotion 2013” the Japan Ministry of Health, Labour and Welfare publication gives reference values for cardiorespiratory fitness (CRF) required for good health. We examined the associations between the CRF reference values and incidence of type 2 diabetes. Methods This prospective cohort study enrolled 4633 nondiabetic Japanese men aged 20 to 39 years at baseline. CRF was measured using the cycle ergometer test, and maximal oxygen uptake was estimated. On the basis of the CRF reference value, participants were classified into 2 groups: those with values less than the reference value (under-RV) and those with values equal to or greater than reference value (over-RV). Hazard ratios (HRs) and 95% CIs for incident type 2 diabetes were estimated using a Cox proportional hazards model. Results A total of 266 participants developed type 2 diabetes during the 14 years of follow-up. As compared with the under-RV group, the over-RV group had a significantly lower multivariable-adjusted HR for type 2 diabetes (HR 0.67; 95% CI, 0.51–0.89). In receiver operating characteristic analysis, the optimal CRF cut-off value for predicting incident type 2 diabetes was 10.8 metabolic equivalents (sensitivity, 0.64; specificity, 0.64), which was close to the CRF reference value of 11.0 metabolic equivalents. Conclusions The reference CRF value appears to be reasonably valid for prevention of type 2 diabetes, especially among Japanese men younger than 40 years. Development of type 2 diabetes can be prevented by maintaining a CRF level above the reference value. PMID:24240630
NASA Astrophysics Data System (ADS)
Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.
2011-12-01
The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.
References for Haplotype Imputation in the Big Data Era
Li, Wenzhi; Xu, Wei; Li, Qiling; Ma, Li; Song, Qing
2016-01-01
Imputation is a powerful in silico approach to fill in those missing values in the big datasets. This process requires a reference panel, which is a collection of big data from which the missing information can be extracted and imputed. Haplotype imputation requires ethnicity-matched references; a mismatched reference panel will significantly reduce the quality of imputation. However, currently existing big datasets cover only a small number of ethnicities, there is a lack of ethnicity-matched references for many ethnic populations in the world, which has hampered the data imputation of haplotypes and its downstream applications. To solve this issue, several approaches have been proposed and explored, including the mixed reference panel, the internal reference panel and genotype-converted reference panel. This review article provides the information and comparison between these approaches. Increasing evidence showed that not just one or two genetic elements dictate the gene activity and functions; instead, cis-interactions of multiple elements dictate gene activity. Cis-interactions require the interacting elements to be on the same chromosome molecule, therefore, haplotype analysis is essential for the investigation of cis-interactions among multiple genetic variants at different loci, and appears to be especially important for studying the common diseases. It will be valuable in a wide spectrum of applications from academic research, to clinical diagnosis, prevention, treatment, and pharmaceutical industry. PMID:27274952
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
Rigo-Bonnin, Raül; Blanco-Font, Aurora; Canalias, Francesca
2018-05-08
Values of mass concentration of tacrolimus in whole blood are commonly used by the clinicians for monitoring the status of a transplant patient and for checking whether the administered dose of tacrolimus is effective. So, clinical laboratories must provide results as accurately as possible. Measurement uncertainty can allow ensuring reliability of these results. The aim of this study was to estimate measurement uncertainty of whole blood mass concentration tacrolimus values obtained by UHPLC-MS/MS using two top-down approaches: the single laboratory validation approach and the proficiency testing approach. For the single laboratory validation approach, we estimated the uncertainties associated to the intermediate imprecision (using long-term internal quality control data) and the bias (utilizing a certified reference material). Next, we combined them together with the uncertainties related to the calibrators-assigned values to obtain a combined uncertainty for, finally, to calculate the expanded uncertainty. For the proficiency testing approach, the uncertainty was estimated in a similar way that the single laboratory validation approach but considering data from internal and external quality control schemes to estimate the uncertainty related to the bias. The estimated expanded uncertainty for single laboratory validation, proficiency testing using internal and external quality control schemes were 11.8%, 13.2%, and 13.0%, respectively. After performing the two top-down approaches, we observed that their uncertainty results were quite similar. This fact would confirm that either two approaches could be used to estimate the measurement uncertainty of whole blood mass concentration tacrolimus values in clinical laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
The Neurobiology of Reference-Dependent Value Computation
De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.
2009-01-01
A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780
Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George
2013-05-01
The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.
Peplies, J; Jiménez-Pavón, D; Savva, S C; Buck, C; Günther, K; Fraterman, A; Russo, P; Iacoviello, L; Veidebaum, T; Tornaritis, M; De Henauw, S; Mårild, S; Molnár, D; Moreno, L A; Ahrens, W
2014-09-01
The aim of this study is to present age- and sex-specific reference values of insulin, glucose, glycosylated haemoglobin (HbA1c) and the homeostasis model assessment to quantify insulin resistance (HOMA-IR) for pre-pubertal children. The reference population consists of 7074 normal weight 3- to 10.9-year-old pre-pubertal children from eight European countries who participated in at least one wave of the IDEFICS ('identification and prevention of dietary- and lifestyle-induced health effects in children and infants') surveys (2007-2010) and for whom standardised laboratory measurements were obtained. Percentile curves of insulin (measured by an electrochemiluminescence immunoassay), glucose, HbA1c and HOMA-IR were calculated as a function of age stratified by sex using the general additive model for location scale and shape (GAMLSS) method. Levels of insulin, fasting glucose and HOMA-IR continuously show an increasing trend with age, whereas HbA1c shows an upward trend only beyond the age of 8 years. Insulin and HOMA-IR values are higher in girls of all age groups, whereas glucose values are slightly higher in boys. Median serum levels of insulin range from 17.4 and 13.2 pmol l(-1) in 3-<3.5-year-old girls and boys, respectively, to 53.5 and 43.0 pmol l(-1) in 10.5-<11-year-old girls and boys. Median values of glucose are 4.3 and 4.5 mmol l(-1) in the youngest age group and 49.3 and 50.6 mmol l(-1) in the oldest girls and boys. For HOMA-IR, median values range from 0.5 and 0.4 in 3-<3.5-year-old girls and boys to 1.7 and 1.4 in 10.5-<11-year-old girls and boys, respectively. Our study provides the first standardised reference values for an international European children's population and provides the, up to now, largest data set of healthy pre-pubertal children to model reference percentiles for markers of insulin resistance. Our cohort shows higher values of Hb1Ac as compared with a single Swedish study while our percentiles for the other glucose metabolic markers are in good accordance with previous studies.
NASA Astrophysics Data System (ADS)
Li, Y. S.; Durig, J. R.
1982-05-01
The low resolution microwave spectrum of methoxyflurane, CHCl 2CF 2OCH 3, has been recorded from 26.5 to 39.0 GHz. From the spacing of the major transitions it is shown that the value of 2036 MHz for B + C is consistent with the trans-trans or gauche-trans conformers where the first term ( trans or gauche) refers to the internal rotation around the C-C bond. The infrared (40-3500 cm -1) and the Raman (20-3500 cm -1) spectra have been recorded for gaseous and solid methoxyflurane. Additionally, the Raman spectrum of the liquid has been obtained and qualitative depolarization ratios measured. From these data it is shown that the most stable form in the fluid phases at ambient temperature is the gauche-trans conformer but the trans-trans form is the most stable in the solid state. A complete vibrational analysis based on infrared band contours, depolarization values and group frequencies is proposed for this conformer. From the analysis of the low frequency vibrational data, values of some of the barriers to internal rotation are estimated. These results are compared to some similar quantities for some corresponding molecules.
Qi, Haiping; Coplen, Tyler B.; Mroczkowski, Stanley J.; Brand, Willi A.; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt
2016-01-01
RationaleThe widely used l-glutamic acid isotopic reference material USGS41, enriched in both 13C and 15N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41.MethodsUSGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in 13C and 15N together with l-glutamic acid of normal isotopic composition. The δ13C and δ15N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ13CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ13CVPDB = −46.6 mUr), and IAEA-N-1 ammonium sulfate (δ15NAir = +0.43 mUr) and USGS32 potassium nitrate (δ15N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry.ResultsUSGS41a is isotopically homogeneous; the reproducibility of δ13C and δ15N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ13C value of +36.55 mUr relative to VPDB and a δ15N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41.ConclusionsThe new isotopic reference material USGS41a can be used with USGS40 (having a δ13CVPDB value of −26.39 mUr and a δ15NAir value of −4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
Qi, Haiping; Coplen, Tyler B; Mroczkowski, Stanley J; Brand, Willi A; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt
2016-04-15
The widely used l-glutamic acid isotopic reference material USGS41, enriched in both (13) C and (15) N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41. USGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in (13) C and (15) N together with l-glutamic acid of normal isotopic composition. The δ(13) C and δ(15) N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ(13) CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ(13) CVPDB = -46.6 mUr), and IAEA-N-1 ammonium sulfate (δ(15) NAir = +0.43 mUr) and USGS32 potassium nitrate (δ(15) N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry. USGS41a is isotopically homogeneous; the reproducibility of δ(13) C and δ(15) N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ(13) C value of +36.55 mUr relative to VPDB and a δ(15) N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41. The new isotopic reference material USGS41a can be used with USGS40 (having a δ(13) CVPDB value of -26.39 mUr and a δ(15) NAir value of -4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
Hybrid pregnant reference phantom series based on adult female ICRP reference phantom
NASA Astrophysics Data System (ADS)
Rafat-Motavalli, Laleh; Miri-Hakimabad, Hashem; Hoseinian-Azghadi, Elie
2018-03-01
This paper presents boundary representation (BREP) models of pregnant female and her fetus at the end of each trimester. The International Commission on Radiological Protection (ICRP) female reference voxel phantom was used as a base template in development process of the pregnant hybrid phantom series. The differences in shape and location of the displaced maternal organs caused by enlarging uterus were also taken into account. The CT and MR images of fetus specimens and pregnant patients of various ages were used to replace the maternal abdominal pelvic organs of template phantom and insert the fetus inside the gravid uterus. Each fetal model contains 21 different organs and tissues. The skeletal model of the fetus also includes age-dependent cartilaginous and ossified skeletal components. The replaced maternal organ models were converted to NURBS surfaces and then modified to conform to reference values of ICRP Publication 89. The particular feature of current series compared to the previously developed pregnant phantoms is being constructed upon the basis of ICRP reference phantom. The maternal replaced organ models are NURBS surfaces. With this great potential, they might have the feasibility of being converted to high quality polygon mesh phantoms.
Internal consistency of the self-reporting questionnaire-20 in occupational groups
Santos, Kionna Oliveira Bernardes; Carvalho, Fernando Martins; de Araújo, Tânia Maria
2016-01-01
ABSTRACT OBJECTIVE To assess the internal consistency of the measurements of the Self-Reporting Questionnaire (SRQ-20) in different occupational groups. METHODS A validation study was conducted with data from four surveys with groups of workers, using similar methods. A total of 9,959 workers were studied. In all surveys, the common mental disorders were assessed via SRQ-20. The internal consistency considered the items belonging to dimensions extracted by tetrachoric factor analysis for each study. Item homogeneity assessment compared estimates of Cronbach’s alpha (KD-20), the alpha applied to a tetrachoric correlation matrix and stratified Cronbach’s alpha. RESULTS The SRQ-20 dimensions showed adequate values, considering the reference parameters. The internal consistency of the instrument items, assessed by stratified Cronbach’s alpha, was high (> 0.80) in the four studies. CONCLUSIONS The SRQ-20 showed good internal consistency in the professional categories evaluated. However, there is still a need for studies using alternative methods and additional information able to refine the accuracy of latent variable measurement instruments, as in the case of common mental disorders. PMID:27007682
Nasal potential difference measurements in diagnosis of cystic fibrosis: an international survey.
Naehrlich, Lutz; Ballmann, Manfred; Davies, Jane; Derichs, Nico; Gonska, Tanja; Hjelte, Lena; van Konigsbruggen-Rietschel, Silke; Leal, Teresinha; Melotti, Paola; Middleton, Peter; Tümmler, Burkhard; Vermeulen, Francois; Wilschanski, Michael
2014-01-01
The role of nasal potential difference (NPD) measurement as a diagnostic test for cystic fibrosis (CF) is a subject of global controversy because of the lack of validation studies, clear reference values, and standardized protocols for diagnostic NPD. To determine diagnostic NPD frequency, protocols, interpretation, and rater agreement, we surveyed the 18 NPD centres of the European Cystic Fibrosis Society Diagnostic Network Working Group. Fifteen centres reported performing 373 diagnostic NPDs in 2012. Most use the CFF-TDN-SOP (67%) and the chloride-free + isoproterenol response of the side with the largest response (47%) as diagnostic criteria and use centre-specific reference ranges. Rater agreement for five NPD tracings - in general - was good, but poor in tracings with different responses between the two nostrils. NPD is frequently used as a diagnostic and research tool for CF. Performance is highly standardized, centre-specific reference ranges are established, and rater agreement - in general - is good. Centre-independent diagnostic criteria and reference ranges must be defined by multicentre validation studies to improve standardized interpretation for diagnostic use. © 2013.
Comfort Contours: Inter-Axis Equivalence
NASA Astrophysics Data System (ADS)
Griefahn, B.; Bröde, P.
1997-07-01
Inter-axis equivalence for sinusoidal vibrations as stipulated by ISO/DIS 2631 for seated persons was studied by adjusting the acceleration of a horizontal sinusoidal test vibration (x∨y) until it caused equal sensation as a vertical sinusoidal reference motion of the same frequency. The reference vibrations consisted of sine waves ranging from 1·6 to 12·5Hz and were presented with three weighted accelerations ofazw=0·3, 0·6 and 1·2ms-2r.m.s. (reference contours). 26 subjects (15 men, 11 women, 20-55yrs, 153-187cm) participated in the respective experiments. Based on the three reference contours, predicted values for horizontal motions were calculated by using the weighting factors provided in ISO/DIS 2631. The International standard was confirmed insofar as the shape of the contours determined for horizontal motions was independent from vibration magnitudes as sensitivity to fore-and-aft and to lateral motions was similar. However, the accelerations adjusted for horizontal vibrations were considerably lower than predicted, suggesting that the weighing factors provided in ISO/DIS 2631 need to be corrected.
37 CFR 1.78 - Claiming benefit of earlier filing date and cross-references to other applications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and cross-references to other applications. (a)(1) A nonprovisional application or international...-filed copending nonprovisional applications or international applications designating the United States... nonprovisional application or international application designating the United States of America, each prior...
web-based interactive data processing: application to stable isotope metrology.
Verkouteren, R M; Lee, J N
2001-08-01
To address a fundamental need in stable isotope metrology, the National Institute of Standards and Technology (NIST) has established a web-based interactive data-processing system accessible through a common gateway interface (CGI) program on the internet site http://www. nist.gov/widps-co2. This is the first application of a web-based tool that improves the measurement traceability afforded by a series of NIST standard materials. Specifically, this tool promotes the proper usage of isotope reference materials (RMs) and improves the quality of reported data from extensive measurement networks. Through the International Atomic Energy Agency (IAEA), we have defined standard procedures for stable isotope measurement and data-processing, and have determined and applied consistent reference values for selected NIST and IAEA isotope RMs. Measurement data of samples and RMs are entered into specified fields on the web-based form. These data are submitted through the CGI program on a NIST Web server, where appropriate calculations are performed and results returned to the client. Several international laboratories have independently verified the accuracy of the procedures and algorithm for measurements of naturally occurring carbon-13 and oxygen-18 abundances and slightly enriched compositions up to approximately 150% relative to natural abundances. To conserve the use of the NIST RMs, users may determine value assignments for a secondary standard to be used in routine analysis. Users may also wish to validate proprietary algorithms embedded in their laboratory instrumentation, or specify the values of fundamental variables that are usually fixed in reduction algorithms to see the effect on the calculations. The results returned from the web-based tool are limited in quality only by the measurements themselves, and further value may be realized through the normalization function. When combined with stringent measurement protocols, two- to threefold improvements have been realized in the reproducibility of carbon-13 and oxygen-18 determinations across laboratories.
Validated age-specific reference values for CSF total protein levels in children.
Kahlmann, V; Roodbol, J; van Leeuwen, N; Ramakers, C R B; van Pelt, D; Neuteboom, R F; Catsman-Berrevoets, C E; de Wit, M C Y; Jacobs, B C
2017-07-01
To define age-specific reference values for cerebrospinal fluid (CSF) total protein levels for children and validate these values in children with Guillain-Barré syndrome (GBS), acute disseminated encephalomyelitis (ADEM) and multiple sclerosis (MS). Reference values for CSF total protein levels were determined in an extensive cohort of diagnostic samples from children (<18 year) evaluated at Erasmus Medical Center/Sophia Children's Hospital. These reference values were confirmed in children diagnosed with disorders unrelated to raised CSF total protein level and validated in children with GBS, ADEM and MS. The test results of 6145 diagnostic CSF samples from 3623 children were used to define reference values. The reference values based on the upper limit of the 95% CI (i.e. upper limit of normal) were for 6 months-2 years 0.25 g/L, 2-6 years 0.25 g/L, 6-12 years 0.28 g/L, 12-18 years 0.34 g/L. These reference values were confirmed in a subgroup of 378 children diagnosed with disorders that are not typically associated with increased CSF total protein. In addition, the CSF total protein levels in these children in the first 6 months after birth were highly variable (median 0.47 g/L, IQR 0.26-0.65). According to these new reference values, CSF total protein level was elevated in 85% of children with GBS, 66% with ADEM and 23% with MS. More accurate age-specific reference values for CSF total protein levels in children were determined. These new reference values are more sensitive than currently used values for diagnosing GBS and ADEM in children. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kłos, Jacek; Alexander, Millard H.; Kumar, Praveen; Poirier, Bill; Jiang, Bin; Guo, Hua
2016-05-01
We report new and more accurate adiabatic potential energy surfaces (PESs) for the ground X˜ 1A1 and electronically excited C˜ 1B2(21A') states of the SO2 molecule. Ab initio points are calculated using the explicitly correlated internally contracted multi-reference configuration interaction (icMRCI-F12) method. A second less accurate PES for the ground X ˜ state is also calculated using an explicitly correlated single-reference coupled-cluster method with single, double, and non-iterative triple excitations [CCSD(T)-F12]. With these new three-dimensional PESs, we determine energies of the vibrational bound states and compare these values to existing literature data and experiment.
Dose Calculation Evolution for Internal Organ Irradiation in Humans
NASA Astrophysics Data System (ADS)
Jimenez V., Reina A.
2007-10-01
The International Commission of Radiation Units (ICRU) has established through the years, a discrimination system regarding the security levels on the prescription and administration of doses in radiation treatments (Radiotherapy, Brach therapy, Nuclear Medicine). The first level is concerned with the prescription and posterior assurance of dose administration to a point of interest (POI), commonly located at the geometrical center of the region to be treated. In this, the effects of radiation around that POI, is not a priority. The second level refers to the dose specifications in a particular plane inside the patient, mostly the middle plane of the lesion. The dose is calculated to all the structures in that plane regardless if they are tumor or healthy tissue. In this case, the dose is not represented by a point value, but by level curves called "isodoses" as in a topographic map, so you can assure the level of doses to this particular plane, but it also leave with no information about how this values go thru adjacent planes. This is why the third level is referred to the volumetrical description of doses so these isodoses construct now a volume (named "cloud") that give us better assurance about tissue irradiation around the volume of the lesion and its margin (sub clinical spread or microscopic illness). This work shows how this evolution has resulted, not only in healthy tissue protection improvement but in a rise of tumor control, quality of life, better treatment tolerance and minimum permanent secuelae.
Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.
Carter, J F; Fry, B
2013-03-01
The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.
International Laser Ranging Service (ILRS): Terms of Reference
NASA Technical Reports Server (NTRS)
Husson, Van; Noll, Carey
2000-01-01
The International Laser Ranging Service (ILRS) is an established Service within Section II , Advanced Space Technology, of the International Association of Geodesy (IAG). The primary objective of the ILRS is to provide a service to support, through Satellite and Lunar Laser Ranging data and related products, geodetic and geophysical research activities as well as International Earth Rotation Service (IERS) products important to the maintenance of an accurate International Terrestrial Reference Frame (ITRF). The service also develops the necessary standards/specifications and encourages international adherence to its conventions.
2013-01-01
Background The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Methods and findings Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China. The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Conclusions Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships. PMID:23497145
Yang, Qingsheng; Mwenda, Kevin M; Ge, Miao
2013-03-12
The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China.The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships.
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.
Jones, Graham R D; Jackson, Craig
2016-01-30
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhu, Yuanyuan; Yang, Chao; Weng, Mingjiao; Zhang, Yan; Yang, Chunhui; Jin, Yinji; Yang, Weiwei; He, Yan; Wu, Yiqi; Zhang, Yuhua; Wang, Guangyu; RajkumarEzakiel Redpath, Riju James; Zhang, Lei; Jin, Xiaoming; Liu, Ying; Sun, Yuchun; Ning, Ning; Qiao, Yu; Zhang, Fengmin; Li, Zhiwei; Wang, Tianzhen; Zhang, Yanqiao; Li, Xiaobo
2017-01-01
Numerous evidences indicate that aspirin usage causes a significant reduction in colorectal cancer. However, the molecular mechanisms about aspirin preventing colon cancer are largely unknown. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) is a most frequently used method to identify the target molecules regulated by certain compound. However, this method needs stable internal reference genes to analyze the expression change of the targets. In this study, the transcriptional stabilities of several traditional reference genes were evaluated in colon cancer cells treated with aspirin, and also, the suitable internal reference genes were screened by using a microarray and were further identified by using the geNorm and NormFinder softwares, and then were validated in more cell lines and xenografts. We have showed that three traditional internal reference genes, β-actin, GAPDH and α-tubulin, are not suitable for studying gene transcription in colon cancer cells treated with aspirin, and we have identified and validated TMEM208 and PQLC2 as the ideal internal reference genes for detecting the molecular targets of aspirin in colon cancer in vitro and in vivo. This study reveals stable internal reference genes for studying the target genes of aspirin in colon cancer, which will contribute to identify the molecular mechanism behind aspirin preventing colon cancer. PMID:28184026
Zhu, Yuanyuan; Yang, Chao; Weng, Mingjiao; Zhang, Yan; Yang, Chunhui; Jin, Yinji; Yang, Weiwei; He, Yan; Wu, Yiqi; Zhang, Yuhua; Wang, Guangyu; RajkumarEzakiel Redpath, Riju James; Zhang, Lei; Jin, Xiaoming; Liu, Ying; Sun, Yuchun; Ning, Ning; Qiao, Yu; Zhang, Fengmin; Li, Zhiwei; Wang, Tianzhen; Zhang, Yanqiao; Li, Xiaobo
2017-04-04
Numerous evidences indicate that aspirin usage causes a significant reduction in colorectal cancer. However, the molecular mechanisms about aspirin preventing colon cancer are largely unknown. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) is a most frequently used method to identify the target molecules regulated by certain compound. However, this method needs stable internal reference genes to analyze the expression change of the targets. In this study, the transcriptional stabilities of several traditional reference genes were evaluated in colon cancer cells treated with aspirin, and also, the suitable internal reference genes were screened by using a microarray and were further identified by using the geNorm and NormFinder softwares, and then were validated in more cell lines and xenografts. We have showed that three traditional internal reference genes, β-actin, GAPDH and α-tubulin, are not suitable for studying gene transcription in colon cancer cells treated with aspirin, and we have identified and validated TMEM208 and PQLC2 as the ideal internal reference genes for detecting the molecular targets of aspirin in colon cancer in vitro and in vivo. This study reveals stable internal reference genes for studying the target genes of aspirin in colon cancer, which will contribute to identify the molecular mechanism behind aspirin preventing colon cancer.
26 CFR 49.4264(d)-1 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 49.4264(d)-1 Section 49.4264(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES FACILITIES AND SERVICES EXCISE TAXES Transportation of Persons § 49.4264(d)-1 Cross...
NASA Astrophysics Data System (ADS)
Kim, Chan Hyeong; Hyoun Choi, Sang; Jeong, Jong Hwi; Lee, Choonsik; Chung, Min Suk
2008-08-01
A Korean voxel model, named 'High-Definition Reference Korean-Man (HDRK-Man)', was constructed using high-resolution color photographic images that were obtained by serially sectioning the cadaver of a 33-year-old Korean adult male. The body height and weight, the skeletal mass and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The resulting model was then implemented into a Monte Carlo particle transport code, MCNPX, to calculate the dose conversion coefficients for the internal organs and tissues. The calculated values, overall, were reasonable in comparison with the values from other adult voxel models. HDRK-Man showed higher dose conversion coefficients than other models, due to the facts that HDRK-Man has a smaller torso and that the arms of HDRK-Man are shifted backward. The developed model is believed to adequately represent average Korean radiation workers and thus can be used for more accurate calculation of dose conversion coefficients for Korean radiation workers in the future.
FDTD calculations of SAR for child voxel models in different postures between 10 MHz and 3 GHz.
Findlay, R P; Lee, A-K; Dimbylow, P J
2009-08-01
Calculations of specific energy absorption rate (SAR) have been performed on the rescaled NORMAN 7-y-old voxel model and the Electronics and Telecommunications Research Institute (ETRI) child 7-y-old voxel model in the standing arms down, arms up and sitting postures. These calculations were for plane-wave exposure under isolated and grounded conditions between 10 MHz and 3 GHz. It was found that there was little difference at each resonant frequency between the whole-body averaged SAR values calculated for the NORMAN and ETRI 7-y-old models for each of the postures studied. However, when compared with the arms down posture, raising the arms increased the SAR by up to 25%. Electric field values required to produce the International Commission on Non-Ionizing Radiation Protection and Institute of Electrical and Electronic Engineers public basic restriction were calculated, and compared with reference levels for the different child models and postures. These showed that, under certain worst-case exposure conditions, the reference levels may not be conservative.
NASA Astrophysics Data System (ADS)
Chen, Hsi-Chao; Huang, Chen-Yu; Lin, Ssu-Fan; Chen, Sheng-Hui
2011-09-01
Residual or internal stresses directly affect a variety of phenomena including adhesion, generation of crystalline defects, perfection of epitaxial layers and formation of film surface growths such as hillocks and whiskers. Sputtering oxide films with high density promote high compressive stress, and it offers researchers a reference if the value of residual stress could be analyzed directly. Since, the study of residual stress of SiO2 and Nb2O5 thin film deposited by DC magnetron sputtered on hard substrate (BK7) and flexible substrate (PET and PC). A finite element method (FEM) with an equivalent-reference-temperature (ERT) technique had been proposed and used to model and evaluate the intrinsic strains of layered structures. The research has improved the equivalent reference temperature (ERT) technique of the simulation of intrinsic strain for oxygen film. The results have also generalized two models connecting to the lattice volume to predict the residual stress of hard substrate and flexible substrate with error of 3% and 6%, respectively.
Evaluation of human exposure to single electromagnetic pulses of arbitrary shape.
Jelínek, Lukás; Pekárek, Ludĕk
2006-03-01
Transient current density J(t) induced in the body of a person exposed to a single magnetic pulse of arbitrary shape or to a magnetic jump is filtered by a convolution integral containing in its kernel the frequency and phase dependence of the basic limit value adopted in a way similar to that used for reference values in the International Commission on Non-lonising Radiation Protection statement. From the obtained time-dependent dimensionless impact function W(J)(t) can immediately be determined whether the exposure to the analysed single event complies with the basic limit. For very slowly varying field, the integral kernel is extended to include the softened ICNIRP basic limit for frequencies lower than 4 Hz.
Assessment of models proposed for the 1981 revision of the IGRF.
Peddie, N.W.; Fabiano, E.B.
1982-01-01
For the second revision of the International Geomagnetic Reference Field (IGRF), the US National Aeronautics and Space Administration (NASA), the UK Institute of Geological Sciences (IGS), and the US Geological Survey (USGS) submitted proposed models of the Earth's main magnetic field at 1965.0, 1970.0, 1975.0, and 1980.0, and its secular variation during 1980-1985. We assessed the proposed models by comparing them with annual mean values from worldwide magnetic observatories data for 1978-1980 from 63 US magnetic repeat stations, and rates-of-change values for worldwide magnetic observatories for 1965-1985 that were derived from straight lines fitted to annual means for 5-yr intervals. We also mutually compared the 1980 models.-from Authors
Thermodynamic properties of minerals
Robie, Richard A.
1962-01-01
In the ten years since the publication of the national Bureau of Standards comprehensive tables of thermochemical properties, by Rossini and other (1952), a very large body of modern calorimetric and equilibrium data has become available. Because of the complex interrelations among many thermochemical data and the necessity for internal consistency among these values, a complete revision of this standard reference is required. This is also true of the summaries of thermochemical data for the sulfides (Richardson and Jeffes 1952) and for the oxides (Coughlin 1954). The following tables present critically selected values for the heat and free energy of formation, the logarithm of the equilibrium constant of formation Log Kf, the entropy and the molar volume, at 298.15°K (25.0°C) and one atmosphere for minerals.
Transformational leadership in nursing practice.
Doody, Owen; Doody, Catriona M
Traditionally, nurses have been over-managed and led inadequately, yet today they face unprecedented challenges and opportunities. Organisations constantly face changes that require an increasingly adaptive and flexible leadership. This type of adaptive leadership is referred to as 'transformational'; under it, environments of shared responsibilities that influence new ways of knowing are created. Transformational leadership motivates followers by appealing to higher ideas and moral values, where the leader has a deep set of internal values and ideas. This leads to followers acting to sustain the greater good, rather than their own interests, and supportive environments where responsibility is shared. This article focuses on transformational leadership and its application to nursing through the four components of transformational leadership. These are: idealised influence; inspirational motivation; intellectual stimulation; and individual consideration.
NASA Astrophysics Data System (ADS)
Madhavi Latha, T.; Peddi Naidu, P.; Madhusudhana Rao, D. N.; Indira Devi, M.
2012-11-01
Electron density profiles for the International Reference Ionosphere (IRI) 2001 and 2007 models have been utilized in evaluating the D-region conductivity parameter in earth ionosphere wave guide calculations. The day to night shift in reflection height of very low frequency (VLF) waves has been calculated using D-region conductivities derived from IRI models and the results are compared with those obtained from phase variation measurements of VLF transmissions from Rugby (England) made at Visakhapatnam (India). The values derived from the models are found to be much lower than those obtained from the experimental measurements. The values derived from the IRI models are in good agreement with those obtained from exponential conductivity model.
Brosch, Tobias; Coppin, Géraldine; Schwartz, Sophie; Sander, David
2012-06-01
Neuroeconomic research has delineated neural regions involved in the computation of value, referring to a currency for concrete choices and decisions ('economic value'). Research in psychology and sociology, on the other hand, uses the term 'value' to describe motivational constructs that guide choices and behaviors across situations ('core value'). As a first step towards an integration of these literatures, we compared the neural regions computing economic value and core value. Replicating previous work, economic value computations activated a network centered on medial orbitofrontal cortex. Core value computations activated medial prefrontal cortex, a region involved in the processing of self-relevant information and dorsal striatum, involved in action selection. Core value ratings correlated with activity in precuneus and anterior prefrontal cortex, potentially reflecting the degree to which a core value is perceived as internalized part of one's self-concept. Distributed activation pattern in insula and ACC allowed differentiating individual core value types. These patterns may represent evaluation profiles reflecting prototypical fundamental concerns expressed in the core value types. Our findings suggest mechanisms by which core values, as motivationally important long-term goals anchored in the self-schema, may have the behavioral power to drive decisions and behaviors in the absence of immediately rewarding behavioral options.
Revised reference values for selenium intake.
Kipp, A P; Strohm, D; Brigelius-Flohé, R; Schomburg, L; Bechthold, A; Leschik-Bonnet, E; Heseker, H
2015-10-01
The German, Austrian and Swiss nutrition societies are the joint editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of selenium and published them in February 2015. The saturation of selenoprotein P (SePP) in plasma is used as a criterion for the derivation of reference values for selenium intake in adults. For persons from selenium-deficient regions (China) SePP saturation was achieved with a daily intake of 49μg of selenium. When using the reference body weights the D-A-CH reference values are based upon, the resulting estimated value for selenium intake is 70μg/day for men and 60μg/day for women. The estimated value for selenium intake for children and adolescents is extrapolated using the estimated value for adults in relation to body weight. For infants aged 0 to under 4 months the estimated value of 10μg/day was derived from the basis of selenium intake via breast milk. For infants aged 4 to under 12 months this estimated value was used and taking into account the differences regarding body weight an estimated value of 15μg/day was derived. For lactating women compared to non-lactating women a higher reference value of 75μg/day is indicated due to the release of selenium with breast milk. The additional selenium requirement for pregnant women is negligible, so that no increased reference value is indicated. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.
Biomass Scenario Model Documentation: Data and References
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y.; Newes, E.; Bush, B.
2013-05-01
The Biomass Scenario Model (BSM) is a system dynamics model that represents the entire biomass-to-biofuels supply chain, from feedstock to fuel use. The BSM is a complex model that has been used for extensive analyses; the model and its results can be better understood if input data used for initialization and calibration are well-characterized. It has been carefully validated and calibrated against the available data, with data gaps filled in using expert opinion and internally consistent assumed values. Most of the main data sources that feed into the model are recognized as baseline values by the industry. This report documentsmore » data sources and references in Version 2 of the BSM (BSM2), which only contains the ethanol pathway, although subsequent versions of the BSM contain multiple conversion pathways. The BSM2 contains over 12,000 total input values, with 506 distinct variables. Many of the variables are opportunities for the user to define scenarios, while others are simply used to initialize a stock, such as the initial number of biorefineries. However, around 35% of the distinct variables are defined by external sources, such as models or reports. The focus of this report is to provide insight into which sources are most influential in each area of the supply chain.« less
Health-related quality of life in Indian children: A community-based cross-sectional survey
Raj, Manu; Sudhakar, Abish; Roy, Rinku; Champaneri, Bhavik; Joy, Teena Mary; Kumar, Raman Krishna
2017-01-01
Background & objectives: There are limited data on health-related quality of life (HRQOL) related to Indian children. The objective of this study was to construct a generic HRQOL reference for children aged 2-18 yr from a community setting. Methods: The study was a community-based cross-sectional survey. A total of 719 children/adolescents in the age group of 2-18 yr were enrolled using stratified random cluster sampling. A total of 40 clusters (cluster size 18) were selected for the study. The data contained child self-report and parent proxy report from healthy children and their parents/caretakers. The Pediatric Quality of Life Inventory 4.0 (PedsQL4.0) Generic Core Scale was used to collect HRQOL data. Questionnaires were self-administered for parents and children aged 8-18 yr. In the age group of five to seven years, parents assisted the children in filling questionnaires. Results: The mean HRQOL total scores from child self-report and parent proxy report were 87.50±11.10 and 90.10±9.50 respectively, for children aged 2-18 yr. Social functioning had the highest scores and emotional functioning had the lowest scores for the entire sample and subgroups. The mean values for HRQOL in the current study were significantly different from the reference study for both child (87.39 vs. 83.91, P<0.001) and parent proxy reports (90.03 vs. 82.29, P<0.001) when compared between children aged 2-16 yr. Interpretation & conclusions: The study provided reference values for HRQOL in healthy children and adolescents from Kerala, India, that appeared to be different from existing international reference. Similar studies need to be done in different parts of India to generate a country-specific HRQOL reference for Indian children. PMID:28862185
Health-related quality of life in Indian children: A community-based cross-sectional survey.
Raj, Manu; Sudhakar, Abish; Roy, Rinku; Champaneri, Bhavik; Joy, Teena Mary; Kumar, Raman Krishna
2017-04-01
There are limited data on health-related quality of life (HRQOL) related to Indian children. The objective of this study was to construct a generic HRQOL reference for children aged 2-18 yr from a community setting. The study was a community-based cross-sectional survey. A total of 719 children/adolescents in the age group of 2-18 yr were enrolled using stratified random cluster sampling. A total of 40 clusters (cluster size 18) were selected for the study. The data contained child self-report and parent proxy report from healthy children and their parents/caretakers. The Pediatric Quality of Life Inventory 4.0 (PedsQL4.0) Generic Core Scale was used to collect HRQOL data. Questionnaires were self-administered for parents and children aged 8-18 yr. In the age group of five to seven years, parents assisted the children in filling questionnaires. The mean HRQOL total scores from child self-report and parent proxy report were 87.50±11.10 and 90.10±9.50 respectively, for children aged 2-18 yr. Social functioning had the highest scores and emotional functioning had the lowest scores for the entire sample and subgroups. The mean values for HRQOL in the current study were significantly different from the reference study for both child (87.39 vs. 83.91, P<0.001) and parent proxy reports (90.03 vs. 82.29, P<0.001) when compared between children aged 2-16 yr. The study provided reference values for HRQOL in healthy children and adolescents from Kerala, India, that appeared to be different from existing international reference. Similar studies need to be done in different parts of India to generate a country-specific HRQOL reference for Indian children.
International Relations: A Student's Guide to Reference Resources.
ERIC Educational Resources Information Center
Silvester, Elizabeth
Intended for students, this annotated bibliography describes reference materials in International Relations that may be found in either the McLennan or Law Library of McGill University. Scope includes political science, international law, and related areas in the social and behavioral sciences, but titles which relate to the foreign relations of a…
International reference preparations of typhoid vaccine
Melikova, E. N.; Lesnjak, S. V.
1967-01-01
International collaborative laboratory studies on the International Reference Preparations of Typhoid Vaccine have so far failed to provide data on which international units for these vaccines can be based. Further assays carried out using the active mouse protection test, with immunization by the subcutaneous, intraperitoneal or intravenous route, confirmed the findings by some workers that the International Reference Preparation of Typhoid Vaccine (Acetone-Inactivated) (vaccine K) was more effective than the International Reference Preparation of Typhoid Vaccine (Heat-Phenol-Inactivated) (vaccine L), and indicated that intraperitoneal immunization was the most promising method. Vaccine K, together with the material extracted by the acetone in the preparation of the vaccine, had a significantly lower effectiveness (at the 5% probability level) only when intraperitoneal immunization was used. The reasons for the differences found between the various vaccines and routes of immunization are discussed at length. It is suggested that challenge with a strain of Salmonella moscow instead of the strain of Salm. typhi used until now gives a true infection and forms the basis of a reliable method for the potency assay of typhoid vaccines. PMID:5301738
Key paediatric messages from Amsterdam
Barben, Jürg; Bohlin, Kajsa; Everard, Mark L.; Hall, Graham; Pijnenburg, Mariëlle; Priftis, Kostas N.; Rusconi, Franca; Midulla, Fabio
2016-01-01
The Paediatric Assembly of the European Respiratory Society (ERS) maintained its high profile at the 2015 ERS International Congress in Amsterdam. There were symposia on preschool wheeze, respiratory sounds and cystic fibrosis; an educational skills workshop on paediatric respiratory resuscitation; a hot topic session on risk factors and early origins of respiratory diseases; a meet the expert session on paediatric lung function test reference values; and the annual paediatric grand round. In this report the Chairs of the Paediatric Assembly's Groups highlight the key messages from the abstracts presented at the Congress. PMID:27730186
Rietdorf, M; Häse, I
1990-01-01
The use of linen in health and social care should primarily be seen from a hygienic angle. Disproportions between the use of linen in the various fields of health care and the available laundry capacities have a negative hygienic and economic effect. Laundry capacities should, therefore, be calculated on the basis of specialty-specific guidevalues. The authors propose indicators suitable to this aim and present the results of a comprehensive analysis for the inpatient departments of internal medicine, surgery, urology, ophthalmology and otorhinolaryngology.
Improvements in world-wide intercomparison of PV module calibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salis, E.; Pavanello, D.; Field, M.
The calibration of the electrical performance of seven photovoltaic (PV) modules was compared between four reference laboratories on three continents. The devices included two samples in standard and two in high-efficiency crystalline silicon technology, two CI(G)S and one CdTe module. The reference value for each PV module parameter was calculated from the average of the results of all four laboratories, weighted by the respective measurement uncertainties. All single results were then analysed with respect to this reference value using the E n number approach. For the four modules in crystalline silicon technology, the results agreed in general within +/-0.5%, withmore » all values within +/-1% and all E n numbers well within [-1, 1], indicating further scope for reducing quoted measurement uncertainty. Regarding the three thin-film modules, deviations were on average roughly twice as large, i.e. in general from +/-1% to +/-2%. A number of inconsistent results were observable, although within the 5% that can be statistically expected on the basis of the E n number approach. Most inconsistencies can be traced to the preconditioning procedure of one participant, although contribution of other factors cannot be ruled out. After removing these obvious inconsistent results, only two real outliers remained, representing less than 2% of the total number of measurands. The results presented show improved agreement for the calibration of PV modules with respect to previous international exercises. For thin-film PV modules, the preconditioning of the devices prior to calibration measurements is the most critical factor for obtaining consistent results, while the measurement processes seem consistent and repeatable.« less
Improvements in world-wide intercomparison of PV module calibration
Salis, E.; Pavanello, D.; Field, M.; ...
2017-09-14
The calibration of the electrical performance of seven photovoltaic (PV) modules was compared between four reference laboratories on three continents. The devices included two samples in standard and two in high-efficiency crystalline silicon technology, two CI(G)S and one CdTe module. The reference value for each PV module parameter was calculated from the average of the results of all four laboratories, weighted by the respective measurement uncertainties. All single results were then analysed with respect to this reference value using the E n number approach. For the four modules in crystalline silicon technology, the results agreed in general within +/-0.5%, withmore » all values within +/-1% and all E n numbers well within [-1, 1], indicating further scope for reducing quoted measurement uncertainty. Regarding the three thin-film modules, deviations were on average roughly twice as large, i.e. in general from +/-1% to +/-2%. A number of inconsistent results were observable, although within the 5% that can be statistically expected on the basis of the E n number approach. Most inconsistencies can be traced to the preconditioning procedure of one participant, although contribution of other factors cannot be ruled out. After removing these obvious inconsistent results, only two real outliers remained, representing less than 2% of the total number of measurands. The results presented show improved agreement for the calibration of PV modules with respect to previous international exercises. For thin-film PV modules, the preconditioning of the devices prior to calibration measurements is the most critical factor for obtaining consistent results, while the measurement processes seem consistent and repeatable.« less
The effect of peer review on mortality rates.
Krahwinkel, W; Schuler, E; Liebetrau, M; Meier-Hellmann, A; Zacher, J; Kuhlen, R
2016-10-01
Lowering of mortality rates in hospitals with mortality rates higher than accepted reference values for acute myocardial infarction (AMI), congestive heart failure (CHF), pneumonia, stroke, mechanical ventilation (MV) and colorectal surgery by using an external peer review process that identifies areas requiring rectification and implements protocols directed at improving these areas. Retrospective, observational, quality management study using administrative data to compare in-hospital mortality rates (pre and post an external peer review process that included adoption of improvement protocols) with reference values. German general hospitals of a large, private group. Hospitals with mortality rates higher than reference values. Peer review of medical records by experienced, outside physicians triggered by in-hospital mortality rates higher than expected. Inadequacies were identified, improvement protocols enforced and mortality rates subsequently re-examined. Mortality rates 1 year before and 1 year after peer review and protocol use. For AMI, CHF, pneumonia, stroke, MV and colorectal surgery, the mortality rates 1 year post-peer review were significantly decreased as compared to pre-peer review mortality rates. The standardized mortality ratio for all of the above diagnoses was 1.45, 1 year before peer review, and 0.97, 1 year after peer review. The absolute risk reduction of 7.3% translates into 710 deaths in this population which could have been prevented. Peer review triggered and conducted in the manner described here is associated with a significant lowering of in-hospital mortality rates in hospitals that previously had higher than expected mortality rates. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care.
TIGO: a geodetic observatory for the improvement of the global reference frame
NASA Astrophysics Data System (ADS)
Schlueter, Wolfgang; Hase, Hayo; Boeer, Armin
1999-12-01
The Bundesamt fuer Kartographie und Geodaesie (BKG) will provide a major contribution to the improvement and maintenance of the global reference frames: ICRF (International Celestial Reference Frame), ITRF (International Terrestrial Reference Frame) with the operation of TIGO (Transportable Integrated Geodetic Observatory). TIGO is designed as a transportable geodetic observatory which consists of all relevant geodetic space techniques for a fundamental station (including VLBI, SLR, GPS). The transportability of the observatory enables to fill up gaps in the International Space Geodetic Network and to optimize the contribution to the global reference frames. TIGO should operate for a period of 2 to 3 years (at minimum) at one location. BKG is looking for a cooperation with countries willing to contribute to the ITRF and to support the operation of TIGO.
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
Wess, G; Mäurer, J; Simak, J; Hartmann, K
2010-01-01
M-mode is the echocardiographic gold standard to diagnose dilated cardiomyopathy (DCM) in dogs, whereas Simpson's method of discs (SMOD) is the preferred method to detect echocardiographic evidence of disease in humans. To establish reference values for SMOD and to compare those with M-mode measurements. Nine hundred and sixty-nine examinations of 471 Doberman Pinschers. Using a prospective longitudinal study design. Reference values for SMOD were established using 75 healthy Doberman Pinschers >8 years old with <50 ventricular premature contractions (VPCs) in 24 hours. The ability of the new SMOD cut-off values, normalized to body surface area (BSA), for left ventricular end-diastolic volume (LVEDV/BSA >95mL/m(2) ) and end-systolic volume (LVESV/BSA > 55mL/m(2) ) to detect echocardiographic changes in Doberman Pinschers with DCM was compared with currently recommended M-mode values. Dogs with elevated SMOD values but normal M-mode measurements were followed-up using a prospective longitudinal study design. At the final examination 175 dogs were diagnosed with DCM according to both methods (M-mode and SMOD). At previous examinations, M-mode values were abnormal in 142 examinations only, whereas all 175 SMOD already had detected changes. Additionally, 19 of 154 dogs with >100 VPCs/24 hours and normal M-mode values had abnormal SMOD measurement. Six dogs with increased SMOD measurements remained healthy at several follow-up examinations (classified as false positive); in 24 dogs with increased SMOD measurements, no follow-up examinations were available (classified as unclear). SMOD measurements are superior to M-mode to detect early echocardiographic changes in Dobermans with occult DCM. Copyright © 2010 by the American College of Veterinary Internal Medicine.
Reference values for pulmonary diffusing capacity for adult native Finns.
Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L
2017-04-01
Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.
Development of internal forest soil reference samples and testing of digestion methods
J.E. Hislop; J.W. Hornbeck; S.W. Bailey; R.A. Hallett
1998-01-01
Our research requires determinations of total elemental concentrations of forest soils. The lack of certified forest soil reference materials led us to develop internal reference samples. Samples were collected from three soil horizons (Oa, B, and C) at three locations having forested, acidic soils similar to those we commonly analyze. A shatterbox was used to...
2002-01-01
This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations. The first section of the report provides summary tables of all the anatomical and physiological parameters given as reference values in this publication. These results give a comprehensive view of reference values for an individual as influenced by age and gender. The second section describes characteristics of dosimetric importance for the embryo and fetus. Information is provided on the development of the total body and the timing of appearance and development of the various organ systems. Reference values are provided on the mass of the total body and selected organs and tissues, as well as a number of physiological parameters. The third section deals with reference values of important anatomical and physiological characteristics of reference individuals from birth to adulthood. This section begins with details on the growth and composition of the total body in males and females. It then describes and quantifies anatomical and physiological characteristics of various organ systems and changes in these characteristics during growth, maturity, and pregnancy. Reference values are specified for characteristics of dosimetric importance. The final section gives a brief summary of the elemental composition of individuals. Focusing on the elements of dosimetric importance, information is presented on the body content of 13 elements: calcium, carbon, chloride, hydrogen, iodine, iron, magnesium, nitrogen, oxygen, potassium, sodium, sulphur, and phosphorus.
Specifying the ISS Plasma Environment
NASA Technical Reports Server (NTRS)
Minow, Joseph I.; Diekmann, Anne; Neergaard, Linda; Bui, Them; Mikatarian, Ronald; Barsamian, Hagop; Koontz, Steven
2002-01-01
Quantifying the spacecraft charging risks and corresponding hazards for the International Space Station (ISS) requires a plasma environment specification describing the natural variability of ionospheric temperature (Te) and density (Ne). Empirical ionospheric specification and forecast models such as the International Reference Ionosphere (IN) model typically only provide estimates of long term (seasonal) mean Te and Ne values for the low Earth orbit environment. Knowledge of the Te and Ne variability as well as the likelihood of extreme deviations from the mean values are required to estimate both the magnitude and frequency of occurrence of potentially hazardous spacecraft charging environments for a given ISS construction stage and flight configuration. This paper describes the statistical analysis of historical ionospheric low Earth orbit plasma measurements used to estimate Ne, Te variability in the ISS flight environment. The statistical variability analysis of Ne and Te enables calculation of the expected frequency of occurrence of any particular values of Ne and Te, especially those that correspond to possibly hazardous spacecraft charging environments. The database used in the original analysis included measurements from the AE-C, AE-D, and DE-2 satellites. Recent work on the database has added additional satellites to the database and ground based incoherent scatter radar observations as well. Deviations of the data values from the IRI estimated Ne, Te parameters for each data point provide a statistical basis for modeling the deviations of the plasma environment from the IRI model output.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
Koskinen, Hanna; Mikkola, Hennamari; Saastamoinen, Leena K; Ahola, Elina; Martikainen, Jaana E
2015-12-01
To analyze the medium- to long-term impact of generic substitution and the reference price system on the daily cost of antipsychotics in Finland. The additional impact of reference pricing over and above previously implemented generic substitution was also assessed. An interrupted time series design with a control group and segmented regression analysis was used to estimate the effect of the implementation of generic substitution and the reference price system on the daily cost of antipsychotics. The data have 69 monthly values of the average daily cost for each of the studied antipsychotics: 39 months before and 30 months after the introduction of reference pricing. For one of the studied antipsychotic, the time before the introduction of reference pricing could be further divided into time before and after the introduction of generic substitution. According to the model, 2.5 years after the implementation of reference pricing, the daily cost of the studied antipsychotics was 24.6% to 50.6% lower than it would have been if reference pricing had not been implemented. Two and a half years after the implementation of the reference price system, however, the additional impact of reference pricing over and above previously implemented generic substitution was modest, less than 1 percentage point. Although the price competition induced by reference pricing decreased the prices of antipsychotics in Finland in the short-term, the prices had a tendency to stagnate or even to turn in an upward direction in the medium- to long-term. Furthermore, the additional impact of reference pricing over and above previously implemented generic substitution remained quite modest. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Kêkê, L M; Samouda, H; Jacobs, J; di Pompeo, C; Lemdani, M; Hubert, H; Zitouni, D; Guinhouya, B C
2015-06-01
This study aims to compare three body mass index (BMI)-based classification systems of childhood obesity: the French, the International Obesity Task Force (IOTF) and the World Health Organization (WHO) references. The study involved 1382 schoolchildren, recruited from the Lille Academic District in France in May 2009 aged 8.4±1.7 years (4.0-12.0 years). Their mean height and body mass were 131.5±10.9cm and 30.7±9.2kg, respectively, resulting in a BMI of 17.4±3.2kg/m(2). The weight status was defined according to the three systems considered in this study. The agreement between these references was tested using the Cohen's kappa coefficient. The prevalence of overweight was higher with the WHO references (20.0%) in comparison with the French references (13.8%; P<0.0001) and the IOTF (16.2%; P≤0.01). A similar result was found with obesity (WHO: 11.6% vs. IOTF: 6.7%; or French references: 6.7%; P<0.0001). Agreement between the three references ranged from "moderate" to "perfect" (0.43≤κ≤1.00; P<0.0001). Kappa coefficients were higher when the three references were used to classify children as obese (0.63≤κ≤1.00; P<0.0001) as compared to classification in the overweight (obesity excluded) category (0.43≤κ≤0.94; P<0.0001). When sex and age categories (4-6 years vs. 7-12 years) were considered to define the overweight status, the lowest kappa coefficient was found between the French and WHO references in boys aged 7-12 years (κ=0.28; P<0.0001), and the highest one in girls aged 7-12 years between the French references and IOTF (κ=0.97; P<0.0001). As for obesity, agreement between the three references ranged from 0.60 to 1.00 (P<0.0001), with the lowest values obtained in the comparison of the WHO references against French references or IOTF among boys aged 7-12 years (κ=0.60; P<0.0001). Overall, the WHO references yield an overestimation in overweight and/or obesity within this sample of schoolchildren as compared to the French references and the IOTF. The magnitude of agreement coefficients between the three references depends on of both sex and age categories. The French references seem to be in rather close agreement with the IOTF in defining overweight, especially in 7-12-year-old children. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M.; Grau, Ana M.; Champion, Victoria L.; Wallston, Kenneth A.
2010-01-01
This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR = 2.53, 95% CI = 1.12–5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value = .02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted. PMID:20173286
Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M; Grau, Ana M; Champion, Victoria L; Wallston, Kenneth A
2010-02-01
This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR=2.53, 95% CI=1.12-5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value=.02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted.
Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik
2014-05-22
There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen's kappa and "observed agreement". There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and "observed agreement" was above 88%. The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language.
Nilsen, Bente B; Yngve, Agneta; Sjöberg, Agneta; Moraeus, Lotta; Lissner, Lauren; Werner, Bo
2016-10-01
The study compared how four different growth references determined the prevalence of thinness and overweight, based on height and weight measurements from a nationally representative sample of Swedish children from seven to nine years of age. The height and weight measurements of 4518 Swedish schoolchildren aged seven to nine years were carried out in 2008 using a standardised protocol. The prevalence of different degrees of thinness and overweight was calculated using international growth references from the World Health Organization, the International Obesity Task Force and two Swedish growth references from Werner and Karlberg. Depending on which growth reference we used, the prevalence of different degrees of thinness varied from 7.5% to 16.9% for the boys and 6.9% to 13.7% for the girls, while the prevalence of overweight, including obesity and severe obesity, varied from 16.5% to 25.7% for the boys and 18.2 to 25.2% for the girls. There were also significant gender differences depending on the growth reference we used. Using four different growth references, two international and two Swedish, produced wide variations in the prevalence of thinness and overweight, together with significant gender differences. In the absence of a global definition, we need both national and international growth references. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
The perilous effects of racism on blacks.
Clark, V R
2001-01-01
This paper focuses on understanding the perilous effects of interpersonal and institutional racism on the psychological and physiological well-being of Blacks. Interpersonal racism refers to prejudice and discriminatory behaviors directed toward individuals because of their race or ethnicity, and institutional racism refers to formal and informal policies and practices that deny equitable treatment to individuals because of their race or ethnic group affiliation. Racism can psychologically affect Blacks by allowing society to deny their value as individuals, and by compelling them to internalize the racist conceptions of them held by their oppressors. Racist stressors may also lead to increased physiological reactivity which, when sustained for a period of time, can lead to cardiovascular disorders and diseases. To eliminate the effects of racism, it is imperative that further research seek better ways to shield Blacks from these menacing stressors.
Plant gnotobiology: Epiphytic microbes and sustainable agriculture
Kutschera, Ulrich; Khanna, Rajnish
2016-01-01
ABSTRACT In 1963, a monograph by Thomas D. Luckey entitled Germfree Life and Gnotobiology was published, with a focus on animals treated with microbes and reference to the work of Louis Pasteur (1822–1895). Here, we review the history and current status of plant gnotobiology, which can be traced back to the experiments of Jean-Baptiste Boussingault (1801–1887) published in 1838. Since the outer surfaces of typical land plants are much larger than their internal areas, embryophytes “wear their guts on the outside.” We describe the principles of gnotobiological analyses, with reference to epiphytic metylobacteria, and sunflower (Helianthus annuus) as well as Arabidopsis as model dicots. Finally, a Californian field experiment aiming to improve crop yield in strawberries (Fragaria ananassa) is described to document the practical value of this novel research agenda. PMID:27830978
Statistical considerations for harmonization of the global multicenter study on reference values.
Ichihara, Kiyoshi
2014-05-15
The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.
Cuesta-Vargas, Antonio Ignacio; González-Sánchez, Manuel
2014-10-29
Spanish is one of the five most spoken languages in the world. There is currently no published Spanish version of the Örebro Musculoskeletal Pain Questionnaire (OMPQ). The aim of the present study is to describe the process of translating the OMPQ into Spanish and to perform an analysis of reliability, internal structure, internal consistency and concurrent criterion-related validity. Translation and psychometric testing. Two independent translators translated the OMPQ into Spanish. From both translations a consensus version was achieved. A backward translation was made to verify and resolve any semantic or conceptual problems. A total of 104 patients (67 men/37 women) with a mean age of 53.48 (±11.63), suffering from chronic musculoskeletal disorders, twice completed a Spanish version of the OMPQ. Statistical analysis was performed to evaluate the reliability, the internal structure, internal consistency and concurrent criterion-related validity with reference to the gold standard questionnaire SF-12v2. All variables except "Coping" showed a rate above 0.85 on reliability. The internal structure calculation through exploratory factor analysis indicated that 75.2% of the variance can be explained with six components with an eigenvalue higher than 1 and 52.1% with only three components higher than 10% of variance explained. In the concurrent criterion-related validity, several significant correlations were seen close to 0.6, exceeding that value in the correlation between general health and total value of the OMPQ. The Spanish version of the screening questionnaire OMPQ can be used to identify Spanish patients with musculoskeletal pain at risk of developing a chronic disability.
ERIC Educational Resources Information Center
Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.
2016-01-01
The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…
Calibrating NIST SRM 683 as A New International Reference Standard for Zn Isotopes
NASA Astrophysics Data System (ADS)
Yang, Y.; Zhang, X.; Yu, H.; Huang, F.
2017-12-01
Zinc isotopes have been widely applied in the cosmochemical, geochemical, and environmental studies (Moynier et al. 2017). Obtaining precise Zn isotopic data for inter-laboratory comparison is a prerequisite to these applications. Currently, the JMC3-0749L is the primary reference standard for Zn isotopes (Albarède 2004), but it is not commercially available now. Thus, it is necessary to calibrate a new international primary reference standard for Zn isotopic analysis. Chen et al. (2016) showed that NIST SRM 683 (a pure Zn metal nugget of 140 grams) has a δ66ZnJMC of 0.12‰, which is falling within the range of natural Zn isotopic compositions, and it may a good candidate for the next generation of international reference standard (Chen et al. 2016). In order to further examine whether NIST SRM 683 has a homogeneous Zn isotopic composition, we measured more NIST SRM 683 by double-spike methods using MC-ICPMS (Conway et al. 2013). The metal nuggets of NIST SRM 683 were intensively sampled by micro-drilling. Zinc isotope analyses for two nuggets show that they have δ66Zn of 0.14 ± 0.02‰ (2SD, N = 32) and 0.13 ± 0.02‰ (2SD, N = 33), respectively. These values are similar to those of two Zn metal nuggets (0.11 ± 0.02‰ vs. 0.12 ± 0.02‰) reported previously by Chen et al. (2016). We fully dissolved one nugget, producing pure Zn solution with identical Zn isotopic composition with the drilling samples. All results strongly support that NIST SRM 683 is homogeneous in Zn isotopic compositions which could be an ideal candidate for the next reference for Zn isotopes. Tests on more metal nuggets will be performed in a few months for further confirming the Zn isotope compositions and homogeneity. Reference: Albarède et al., 2004. 'The stable isotope geochemistry of copper and zinc', Reviews in Mineralogy and Geochemistry, 55: 409-27. Chen et al., 2016. 'Zinc Isotopic Compositions of NIST SRM 683 and Whole-Rock Reference Materials', Geostandards and Geoanalytical Research, 40: 417-32. Conway et al., 2013. 'A new method for precise determination of iron, zinc and cadmium stable isotope ratios in seawater by double-spike mass spectrometry', Analytica chimica acta, 793: 44-52. Moynier et al., 2017. 'The isotope geochemistry of zinc and copper', Reviews in Mineralogy and Geochemistry, 82: 543-600.
Reliability of reference distances used in photogrammetry.
Aksu, Muge; Kaya, Demet; Kocadereli, Ilken
2010-07-01
To determine the reliability of the reference distances used for photogrammetric assessment. The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.
26 CFR 56.6001-1 - Notice or regulations requiring records, statements, and special returns.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., statements, and special returns. 56.6001-1 Section 56.6001-1 Internal Revenue INTERNAL REVENUE SERVICE..., of the Code, by treating each reference to chapter 42 in § 53.6001-1 as a reference to chapter 41. (b) Cross references. See § 56.4911-6 for general information on records of lobbying expenditures. See §§ 56...
The Study and Measurement of Values and Attitudes.
ERIC Educational Resources Information Center
Kerlinger, Fred N.
The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…
USDA-ARS?s Scientific Manuscript database
Nutrient reference values have significant public health and policy implications. Given the importance of defining reliable nutrient reference values, there is a need for an explicit, objective, and transparent process to set these values. The Tufts Medical Center Evidence-based Practice Center asse...
Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine
2018-03-01
The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.
The importance of reference materials in doping-control analysis.
Mackay, Lindsey G; Kazlauskas, Rymantas
2011-08-01
Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.
Mixing induced by a propagating normal mode in long term experiments
NASA Astrophysics Data System (ADS)
Dossmann, Yvan; Pollet, Florence; Odier, Philippe; Dauxois, Thierry
2017-04-01
The energy pathways from propagating internal waves to the scales of irreversible mixing in the ocean are numerous. The triadic resonant instability (TRI) is an intrinsic destabilization process that can lead to mixing away from topographies. It consists in the destabilization of a primary internal wave generation leading to the radiation of two secondary waves of lower frequencies and different wave vectors. In the process, internal wave energy is carried down to smaller scales. A previous study focused on the assessment of instantaneous turbulent fluxes fields associated with the TRI process in laboratory experiments [1]. The present study investigates the integrated impact of mixing processes induced by a propagative normal mode over long term experiments using a similar setup. Configurations for which the TRI process is either favored or inhibited are tackled. Optical measurements using the light attenuation technique allow to follow the internal waves dynamics and the evolution of the density profile between two runs of one hour typical duration. The horizontally averaged turbulent diffusivity Kt(z) and the mixing efficiency Γ are assessed. One finds values up to Kt = 10-6 m2/s and Γ = 11 %, with slightly larger values in the presence of TRI. The maximum value for Kt is measured at the position(s) of the maximum shear normal mode shear for both normal modes 1 and 2. The development of staircases in the density profile is observed after several hours of forcing. This mechanism can be explained by Phillips' argument by which sharp interfaces can form due to vertical variations of the buoyancy flux. The staircases are responsible for large variations in the vertical distribution of turbulent diffusivity. These results could help to refine parameterizations of the impact of low order normal modes in ocean mixing. Reference : [1] Dossmann et al. 2016, Mixing by internal waves quantified using combined PIV/PLIF technique, Experiments in Fluids, 57, 132.
Low Shrinkage Cement Concrete Intended for Airfield Pavements
NASA Astrophysics Data System (ADS)
Małgorzata, Linek
2017-10-01
The work concerns the issue of hardened concrete parameters improvement intended for airfield pavements. Factors which have direct or indirect influence on rheological deformation size were of particular interest. The aim of lab testing was to select concrete mixture ratio which would make hardened concrete less susceptible to influence of basic operating factors. Analyses included two research groups. External and internal factors were selected. They influence parameters of hardened cement concrete by increasing rheological deformations. Research referred to innovative cement concrete intended for airfield pavements. Due to construction operation, the research considered the influence of weather conditions and forced thermal loads intensifying concrete stress. Fresh concrete mixture parameters were tested and basic parameters of hardened concrete were defined (density, absorbability, compression strength, tensile strength). Influence of the following factors on rheological deformation value was also analysed. Based on obtained test results, it has been discovered that innovative concrete, made on the basis of modifier, which changes internal structure of concrete composite, has definitely lower values of rheological deformation. Observed changes of microstructure, in connection with reduced deformation values allowed to reach the conclusion regarding advantageous characteristic features of the newly designed cement concrete. Applying such concrete for airfield construction may contribute to extension of its operation without malfunction and the increase of its general service life.
Oil Characteristics of Four Palestinian Olive Varieties.
Lodolini, Enrico Maria; Polverigiani, Serena; Ali, Saed; Mutawea, Mohammed; Qutub, Mayyada; Arabasi, Taysir; Pierini, Fabio; Abed, Mohammed; Neri, Davide
2017-05-01
Olive oil represents an important source of income for Palestinian farmers in local, national and international markets. Sometimes, olive oil produced in local climatic conditions, does not achieve the International Olive Council (IOC) trade standards so that international markets are precluded. The oil chemical composition and sensory profile of four Palestinian olive varieties (Nabali Baladi, Nabali Mohassan, Souri and K18) were characterized in 2010 throughout an in situ evaluation. Most of the physicchemical characteristics and the fatty acid composition of the varieties met the International Olive Council trade standards (IOC-TS) for extra virgin olive oils. Values of K 270 for Nabali Baladi and linolenic acid for Souri slightly exceeded the limit. Eicosanoic acid exceeded the IOC-TS limits in the oils of all considered varieties. Among the sterols, the Δ-7-stigmastenol resulted too high for Nabali Baladi and Souri. Sensory profile for the tested varieties showed a reminiscence of tomato or artichoke and light to medium bitter and pungent sensations. Results represent an important baseline reference for further studies about oil composition and quality of the main Palestinian olive germplasm and provide indication of potential critical points to be controlled in order to ensure the full achievement of IOC-TS and access international markets.
Masala, Silvia; Ahmed, Trifa; Bergvall, Christoffer; Westerholm, Roger
2011-12-01
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.
Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.
Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C
1999-10-01
The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.
Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal
2005-03-01
Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.
Kleine, Tilmann O; Nebe, C Thomas; Löwer, Christa; Lehmitz, Reinhard; Kruse, Rolf; Geilenkeuser, Wolf-Jochen; Dorn-Beineke, Alexandra
2009-08-01
Flow cytometry (FCM) is used with haematology analyzers (HAs) to count cells and differentiate leukocytes in cerebrospinal fluid (CSF). To evaluate the FCM techniques of HAs, 10 external DGKL trials with CSF controls were carried out in 2004 to 2008. Eight single platform HAs with and without CSF equipment were evaluated with living blood leukocytes and erythrocytes in CSF like DGKL controls: Coulter (LH750,755), Abbott CD3200, CD3500, CD3700, CD4000, Sapphire, ADVIA 120(R) CSF assay, and Sysmex XE-2100(R). Results were compared with visual counting of native cells in Fuchs-Rosenthal chamber, unstained, and absolute values of leukocyte differentiation, assayed by dual platform analysis with immune-FCM (FACSCalibur, CD45, CD14) and the chamber counts. Reference values X were compared with HA values Y by statistical evaluation with Passing/Bablock (P/B) linear regression analysis to reveal conformity of both methods. The HAs, studied, produced no valid results with DGKL CSF controls, because P/B regression revealed no conformity with the reference values due to:-blank problems with impedance analysis,-leukocyte loss with preanalytical erythrocyte lysis procedures, especially of monocytes,-inaccurate results with ADVIA cell sphering and cell differentiation with algorithms and enzyme activities (e.g., peroxidase). HA techniques have to be improved, e.g., using no erythrocyte lysis and CSF adequate techniques, to examine CSF samples precise and accurate. Copyright 2009 International Society for Advancement of Cytometry.
Bel Hadj Hmida, Y; Tahri, N; Sellami, A; Yangui, N; Jlidi, R; Beyrouti, M I; Krichen, M S; Masmoudi, H
2001-01-01
In order to determine the sensitivity of CEA in the diagnosis of colo-rectal carcinoma, we studied a series of 48 patients with colo-rectal carcinoma (1992-1996). The sensitivity was at 52% with a reference value of 5 ng/ml and 68.7% for a reference value of 2.5 ng/ml. With a reference value of 5 ng/ml, the sensitivity of CEA was at 37% only for patients with colo-rectal carcinoma at Dukes B stage, 66.6% for patients at stage C and 75% for patients at stage D. The dosage of CEA was carried out with a sandwich immunoenzymatic technique in tube. There is no statistic significant correlation between the pre-operative rate of CEA and the localisation of the tumor and its histologic type; in contrast, it was significantly correlated with the ganglionnary metastasis. A significant relationship between the pre-operative rate of CEA and the Dukes stage was found for a reference value of 10 ng/ml but not for a reference value of 5 ng/ml. We calculated the specificity of the CEA for the cancers of colon and rectum which was at 76.98% with a reference value of 5 ng/ml and 86% with a reference value of 10 ng/ml.
[On the way to national reference system of laboratory medicine].
Muravskaia, N P; Men'shikov, V V
2014-10-01
The application of standard samples and reference techniques of implementation of measurements is needed for a valid support of reliability of analyses applied in clinical diagnostic laboratories. They play role of landmarks under metrologic monitoring, calibration of devices and control of quality of results. The article presents analysis of shortcomings interfering with formation of national reference system in Russia harmonized with possibilities provided by international organizations. Among them are the joint Committee on metrologic monitoring in laboratory medicine under the auspices of the International Bureau of Weights and Measures, the International Federation of clinical chemistry and laboratory medicine, etc. The results of the recent development of national normative documents, standard samples and techniques assisted by the authors of article are considered. They are the first steps to organization of national reference system which would comprise all range of modern analytical technologies of laboratory medicine. The national and international measures are proposed to enhance the promptest resolving of task of organization of national reference system for laboratory medicine in the interests of increasing of effectiveness of medical care to citizen of Russia.
Holler, P J; Wess, G
2014-01-01
E-point-to-septal-separation (EPSS) and the sphericity index (SI) are echocardiographic parameters that are recommended in the ESVC-DCM guidelines. However, SI cutoff values to diagnose dilated cardiomyopathy (DCM) have never been evaluated. To establish reference ranges, calculate cutoff values, and assess the clinical value of SI and EPSS to diagnose DCM in Doberman Pinschers. One hundred seventy-nine client-owned Doberman Pinschers. Three groups were formed in this prospective longitudinal study according to established Holter and echocardiographic criteria using the Simpson method of disk (SMOD): control group (97 dogs), DCM with echocardiographic changes (75 dogs) and "last normal" group (n = 7), which included dogs that developed DCM within 1.5 years, but were still normal at this time point. In a substudy, dogs with early DCM based upon SMOD values above the reference range but still normal M-Mode measurements were selected, to evaluate if EPSS or SI were abnormal using the established cutoff values. ROC-curve analysis determined <1.65 for the SI (sensitivity 86.8%; specificity 87.6%) and >6.5 mm for EPSS (sensitivity 100%; specificity 99.0%) as optimal cutoff values to diagnose DCM. Both parameters were significantly different between the control group and the DCM group (P < 0.001), but were not abnormal in the "last normal" group. In the substudy, EPSS was abnormal in 13/13 dogs and SI in 2/13 dogs. E-point-to-septal-separation is a valuable additional parameter for the diagnosis of DCM, which can enhance diagnostic capabilities of M-Mode and which performs similar as well as SMOD. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Internal photon and electron dosimetry of the newborn patient—a hybrid computational phantom study
NASA Astrophysics Data System (ADS)
Wayson, Michael; Lee, Choonsik; Sgouros, George; Treves, S. Ted; Frey, Eric; Bolch, Wesley E.
2012-03-01
Estimates of radiation absorbed dose to organs of the nuclear medicine patient are a requirement for administered activity optimization and for stochastic risk assessment. Pediatric patients, and in particular the newborn child, represent that portion of the patient population where such optimization studies are most crucial owing to the enhanced tissue radiosensitivities and longer life expectancies of this patient subpopulation. In cases where whole-body CT imaging is not available, phantom-based calculations of radionuclide S values—absorbed dose to a target tissue per nuclear transformation in a source tissue—are required for dose and risk evaluation. In this study, a comprehensive model of electron and photon dosimetry of the reference newborn child is presented based on a high-resolution hybrid-voxel phantom from the University of Florida (UF) patient model series. Values of photon specific absorbed fraction (SAF) were assembled for both the reference male and female newborn using the radiation transport code MCNPX v2.6. Values of electron SAF were assembled in a unique and time-efficient manner whereby the collisional and radiative components of organ dose--for both self- and cross-dose terms—were computed separately. Dose to the newborn skeletal tissues were assessed via fluence-to-dose response functions reported for the first time in this study. Values of photon and electron SAFs were used to assemble a complete set of S values for some 16 radionuclides commonly associated with molecular imaging of the newborn. These values were then compared to those available in the OLINDA/EXM software. S value ratios for organ self-dose ranged from 0.46 to 1.42, while similar ratios for organ cross-dose varied from a low of 0.04 to a high of 3.49. These large discrepancies are due in large part to the simplistic organ modeling in the stylized newborn model used in the OLINDA/EXM software. A comprehensive model of internal dosimetry is presented in this study for the newborn nuclear medicine patient based upon the UF hybrid computational phantom. Photon dose response functions, photon and electron SAFs, and tables of radionuclide S values for the newborn child--both male and female--are given in a series of four electronic annexes available at stacks.iop.org/pmb/57/1433/mmedia. These values can be applied to optimization studies of image quality and stochastic risk for this most vulnerable class of pediatric patients.
International Laser Ranging Service (ILRS) 2003-2004 Annual Report
NASA Technical Reports Server (NTRS)
Pearlman, Michael (Editor); Noll, Carey (Editor)
2005-01-01
The International Laser Ranging Service (ILRS) organizes and coordinates Satellite Laser Ranging (SLR) and Lunar Laser Ranging (LLR) to support programs in geodetic, geophysical, and lunar research activities and provides the International Earth Rotation and Reference Systems Service (IERS) with products important to the maintenance of an accurate International Terrestrial Reference Frame (ITRF). This reference frame provides the stability through which systematic measurements of the Earth can be made over thousands of kilometers, decades of time, and evolution of measurement technology. This 2003-2004 ILRS annual report is comprised of individual contributions from ILRS components within the international geodetic community for the years 2003-2004. The report documents changes and progress of the ILRS and is also available on the ILRS Web site at http://ilrs.gsfc.nasa.gov/reports/ilrs_reports/ilrsar_2003.html.
ERIC Educational Resources Information Center
Fraser, Renee White; Shani, Hadasa
Intended as a companion piece to volume 2 in the Method Series, Environmental Health Planning (CE 024 230), this second of six volumes in the International Health Planning Reference Series is a combined literature review and annotated bibliography dealing with environmental factors in health planning for developing countries. The review identifies…
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
de Vega-Bartol, José J; Santos, Raquen Raissa; Simões, Marta; Miguel, Célia M
2013-05-01
Suitable internal control genes to normalize qPCR data from different stages of embryo development and germination were identified in two representative conifer species. Clonal propagation by somatic embryogenesis has a great application potentiality in conifers. Quantitative PCR (qPCR) is widely used for gene expression analysis during somatic embryogenesis and embryo germination. No single reference gene is universal, so a systematic characterization of endogenous genes for concrete conditions is fundamental for accuracy. We identified suitable internal control genes to normalize qPCR data obtained at different steps of somatic embryogenesis (embryonal mass proliferation, embryo maturation and germination) in two representative conifer species, Pinus pinaster and Picea abies. Candidate genes included endogenous genes commonly used in conifers, genes previously tested in model plants, and genes with a lower variation of the expression along embryo development according to genome-wide transcript profiling studies. Three different algorithms were used to evaluate expression stability. The geometric average of the expression values of elongation factor-1α, α-tubulin and histone 3 in P. pinaster, and elongation factor-1α, α-tubulin, adenosine kinase and CAC in P. abies were adequate for expression studies throughout somatic embryogenesis. However, improved accuracy was achieved when using other gene combinations in experiments with samples at a single developmental stage. The importance of studies selecting reference genes to use in different tissues or developmental stages within one or close species, and the instability of commonly used reference genes, is highlighted.
On fair, effective and efficient REDD mechanism design
2009-01-01
The issues surrounding 'Reduced Emissions from Deforestation and Forest Degradation' (REDD) have become a major component of continuing negotiations under the United Nations Framework Convention on Climate Change (UNFCCC). This paper aims to address two key requirements of any potential REDD mechanism: first, the generation of measurable, reportable and verifiable (MRV) REDD credits; and secondly, the sustainable and efficient provision of emission reductions under a robust financing regime. To ensure the supply of MRV credits, we advocate the establishment of an 'International Emission Reference Scenario Coordination Centre' (IERSCC). The IERSCC would act as a global clearing house for harmonized data to be used in implementing reference level methodologies. It would be tasked with the collection, reporting and subsequent processing of earth observation, deforestation- and degradation driver information in a globally consistent manner. The IERSCC would also assist, coordinate and supervise the computation of national reference scenarios according to rules negotiated under the UNFCCC. To overcome the threats of "market flooding" on the one hand and insufficient economic incentives for REDD on the other hand, we suggest an 'International Investment Reserve' (IIR) as REDD financing framework. In order to distribute the resources of the IIR we propose adopting an auctioning mechanism. Auctioning not only reveals the true emission reduction costs, but might also allow for incentivizing the protection of biodiversity and socio-economic values. The introduced concepts will be vital to ensure robustness, environmental integrity and economic efficiency of the future REDD mechanism. PMID:19943927
EDQM biological reference preparation for rabies vaccine (inactivated) for veterinary use.
Daas, A; Bruckner, L; Milne, C
2015-01-01
Rabies is a deadly zoonotic disease. Control of rabies in animals by vaccination is an important strategy to protect humans from infection and control the spread of the disease. Requirements for the quality control of rabies vaccines (inactivated) for veterinary use include an in vivo quantitative potency determination as outlined in the Ph. Eur. monograph 0451. Performance of this assay requires a reference preparation calibrated in International Units (IU). A European Pharmacopeia (Ph. Eur.) Biological Reference Preparation (BRP) for rabies vaccines (inactivated) for veterinary use, calibrated in IU, has been established for this purpose. Due to the dwindling stocks of the current batch (batch 4) of Ph. Eur. BRP for rabies vaccines (inactivated) for veterinary use, a collaborative study was run as part of the EDQM Biological Standardisation Programme to establish BRP batch 5. Ten laboratories, including Official Medicines Control Laboratories and manufacturers, participated. The candidate BRP5 was assayed against the 6(th) International Standard for rabies vaccine using the in vivo vaccination-challenge assay (monograph 0451) to assign a potency value. The candidate was also compared to BRP batch 4 to establish continuity. Taking into account the results from the comparisons a potency of 10 IU/vial was assigned and in March 2015 the Ph. Eur. Commission adopted the material as Ph. Eur. BRP for rabies vaccines (inactivated) for veterinary use batch 5. In addition to the in vivo assay 3 laboratories tested the candidate material using their in-house in vitro assays for information.
Global health interdependence and the international physicians' movement.
Gellert, G A
1990-08-01
International Physicians for the Prevention of Nuclear War has had an impressive public impact in the 1980s, helping to shatter the myths of surviving and medically responding to a nuclear attack. The 1990s present a new challenge for the medical community in a different social and international context characterized by increasing global interdependence. Another view of physician activism is presented to complement advocacy for nuclear disarmament in the promotion of peace. A framework for analysis is provided by "fateful visions"--accepted policy views of prospective superpower relations--drawn from practitioners of foreign policy, international relations, and security affairs. A perceptual gap may exist between physicians who wish to address underlying ethical and public health concerns on security issues and policy practitioners who are accustomed to discussion within existing policy frames of reference that can be pragmatically used. A strategy is proposed for physicians to use their specialized training and skills to evaluate trends in global health interdependence. The international physicians' movement may contribute substantively to the formulation of policy by expanding and interpreting an increasingly complex database on interdependence, and by creating a dialogue with policy formulators based on mutual recognition of the value and legitimacy of each professions' expertise and complementary contributions to international security policy.
The rotational elements of Mars and its satellites
NASA Astrophysics Data System (ADS)
Jacobson, R. A.; Konopliv, A. S.; Park, R. S.; Folkner, W. M.
2018-03-01
The International Astronomical Union (IAU) defines planet and satellite coordinate systems relative to their axis of rotation and the angle about that axis. The rotational elements of the bodies are the right ascension and declination of the rotation axis in the International Celestial Reference Frame and the rotation angle, W, measured easterly along the body's equator. The IAU specifies the location of the body's prime meridian by providing a value for W at epoch J2000. We provide new trigonometric series representations of the rotational elements of Mars and its satellites, Phobos and Deimos. The series for Mars are from a least squares fit to the rotation model used to orient the Martian gravity field. The series for the satellites are from a least squares fit to rotation models developed in accordance with IAU conventions from recent ephemerides.
Nutrient reference value: non-communicable disease endpoints--a conference report.
Lupton, J R; Blumberg, J B; L'Abbe, M; LeDoux, M; Rice, H B; von Schacky, C; Yaktine, A; Griffiths, J C
2016-03-01
Nutrition is complex-and seemingly getting more complicated. Most consumers are familiar with "essential nutrients," e.g., vitamins and minerals, and more recently protein and important amino acids. These essential nutrients have nutrient reference values, referred to as dietary reference intakes (DRIs) developed by consensus committees of scientific experts convened by the Institute of Medicine of the National Academy of Sciences, Engineering, and Medicine and carried out by the Food and Nutrition Board. The DRIs comprise a set of four nutrient-based reverence values, the estimated average requirements, the recommended dietary allowances (RDAs), the adequate intakes and the tolerable upper intake levels for micronutrient intakes and an acceptable macronutrient distribution range for macronutrient intakes. From the RDA, the US Food and Drug Administration (FDA) derives a labeling value called the daily value (DV), which appears on the nutrition label of all foods for sale in the US. The DRI reports do not make recommendations about whether the DV labeling values can be set only for what have been defined to date as "essential nutrients." For example, the FDA set a labeling value for "dietary fiber" without having the DV. Nutrient reference values-requirements are set by Codex Alimentarius for essential nutrients, and regulatory bodies in many countries use these Codex values in setting national policy for recommended dietary intakes. However, the focus of this conference is not on essential nutrients, but on the "nonessential nutrients," also termed dietary bioactive components. They can be defined as "Constituents in foods or dietary supplements, other than those needed to meet basic human nutritional needs, which are responsible for changes in health status (Office of Disease Prevention and Health Promotion, Office of Public Health and Science, Department of Health and Human Services in Fed Regist 69:55821-55822, 2004)." Substantial and often persuasive scientific evidence does exist to confirm a relationship between the intake of a specific bioactive constituent and enhanced health conditions or reduced risk of a chronic disease. Further, research on the putative mechanisms of action of various classes of bioactives is supported by national and pan-national government agencies, and academic institutions, as well as functional food and dietary supplement manufacturers. Consumers are becoming educated and are seeking to purchase products containing bioactives, yet there is no evaluative process in place to let the public know how strong the science is behind the benefits or the quantitative amounts needed to achieve these beneficial health effects or to avoid exceeding the upper level (UL). When one lacks an essential nutrient, overt deficiency with concomitant physiological determents and eventually death are expected. The absence of bioactive substances from the diet results in suboptimal health, e.g., poor cellular and/or physiological function, which is relative and not absolute. Regrettably at this time, there is no DRI process to evaluate bioactives, although a recent workshop convened by the National Institutes of Health (Options for Consideration of Chronic Disease Endpoints for Dietary Reference Intakes (DRIs); March 10-11, 2015; http://health.gov/dietaryguidelines/dri/ ) did explore the process to develop DVs for nutrients, the lack of which result in increased risk of chronic disease (non-communicable disease) endpoints. A final report is expected soon. This conference (CRN-International Scientific Symposium; "Nutrient Reference Value-Non-Communicable Disease (NRV-NCD) Endpoints," 20 November in Kronberg, Germany; http://www.crn-i.ch/2015symposium/ ) explores concepts related to the Codex NRV process, the public health opportunities in setting NRVs for bioactive constituents, and further research and details on the specific class of bioactives, n-3 long-chain polyunsaturated fatty acids (also termed omega-3 fatty acids) and their constituents, specifically docosahexaenoic acid and eicosapentaenoic acid.
Search Codes for a Bibliography for the Study of African International Relations
1975-01-01
Soja (1970). A high speed ln-house reference system was needed to facilitate storage, search, and retrieval of bibliographic reference materlal...REfUBLIC 0F (N0R™ KUW KUWAIT LAB LABOR UNIONS, INTERNATIONAL ASPECTS l- LA LAND LOCKED NATIONS LAO LAOS LAT LATIN AliERICA LAW I AW, INTERNATIONAL...IOCRATIC PEOPLE’S REPUBLIC OF (NORTH) KÜS KOREA (SOUTH) KUW KUWA I T LAb LABOR UNIONS, INTERNATIONAL ASPECTS LAU LA )S I.AT LATIN AiiEUICA LAN
Wassenaar, L I; Terzer-Wassmuth, S; Douence, C; Araguas-Araguas, L; Aggarwal, P K; Coplen, T B
2018-03-15
Water stable isotope ratios (δ 2 H and δ 18 O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test. Eight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies. For the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ 18 O and δ 2 H, respectively; ~27 % produced unacceptable results. Top performance for δ 18 O values was dominated by dual-inlet IRMS laboratories; top performance for δ 2 H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected. Analysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1-2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples. Copyright © 2018 John Wiley & Sons, Ltd.
Wassenaar, L. I.; Terzer-Wassmuth, S.; Douence, C.; Araguas-Araguas, L.; Aggarwal, P. K.; Coplen, Tyler B.
2018-01-01
RationaleWater stable isotope ratios (δ2H and δ18O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test.MethodsEight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies.ResultsFor the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ18O and δ2H, respectively; ~27 % produced unacceptable results. Top performance for δ18O values was dominated by dual-inlet IRMS laboratories; top performance for δ2H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected.ConclusionsAnalysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1–2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.
Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark
2016-04-01
Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
The International Celestial Reference Frame (ICRF) and the Relationship Between Frames
NASA Technical Reports Server (NTRS)
Ma, Chopo
2000-01-01
The International Celestial Reference Frame (ICRF), a catalog of VLBI source positions, is now the basis for astrometry and geodesy. Its construction and extension/maintenance will be discussed as well as the relationship of the ICRF, ITRF, and EOP/nutation.
A novel anti-theft security system for photovoltaic modules
NASA Astrophysics Data System (ADS)
Khan, Wasif Ali; Lim, Boon-Han; Lai, An-Chow; Chong, Kok-Keong
2017-04-01
Solar farms are considered as easy target for thieves because of insufficient protection measures. Existing anti-theft approaches are based on system level and are not very preventive and efficient because these can be bypassed with some technical knowledge. Additionally, it is difficult for security guards to tackle them as robbers come in a form of a gang equipped with heavy weapons. In this paper, a low power auto shut-off and non-destructive system is proposed for photovoltaic (PV) modules to achieve better level of security at module level. In proposed method, the power generation function of the PV module will be shut-off internally and cannot be re-activated by unauthorized personnel, in the case of theft. Hence, the PV module will not be functional even sold to new customers. The system comprises of a microcontroller, a low power position sensor, a controllable semiconductor switch and a wireless reactive-able system. The anti-theft system is developed to be laminated inside PV module and will be interconnected with solar cells so it becomes difficult for thieves to temper. The position of PV module is retrieved by position sensor and stored in a microcontroller as an initial reference value. Microcontroller uses this stored reference value to control power supply of PV module via power switch. The stored reference value can be altered using wireless circuitry by following authentication protocol. It makes the system non-destructive as anti-theft function can be reset again by authorized personnel, if it is recovered after theft or moved for maintenance purposes. The research component includes the design of a position sensing circuit, an auto shut-off circuit, a reactive-able wireless security protection algorithm and finally the integration of the multiple circuits.
Ruaux, Craig; Scollan, Katherine; Suchodolski, Jan S; Steiner, Jörg M; Sisson, D David
2015-09-01
The N-terminal fragment of the prohormone B-type natriuretic peptide (NT-proBNP) and cardiac troponin-I are candidate biomarkers for cardiac disease in dogs. The degree of biologic variation in these biomarkers has not previously been reported in healthy dogs or dogs with mitral regurgitation. The purpose of the study was to derive estimates of intrinsic biologic variability and reference change values for NT-proBNP and cardiac troponin-I in healthy dogs and dogs with mitral regurgitation grade IB and II according to the International Small Animal Cardiac Health Council (ISACHC) grading system. Plasma and sera were collected weekly for up to 7 weeks from 12 control dogs and 9 dogs with mitral regurgitation. NT-proBNP and troponin-I (C-TnI) concentrations were determined. Indices of biologic variation such as reciprocal index of individuality (r-IoI) and reference change values (RCV) were calculated in both the groups. Individuality was high in control dogs and dogs with grade IB and II mitral valve regurgitation for both C-TnI (r-IoI 1.6 and 2) and NT-proBNP (1.5 and 2.7), while the 2-sided RCV for NT-proBNP was significantly lower in dogs with mitral regurgitation (52.5% vs 99.4%, P<0.01.). High individuality of these cardiac biomarkers suggests that, following diagnosis, these assays are best interpreted by serial determination in individual canine patients rather than by comparison to a population-based reference interval. The smaller RCV values for dogs with mitral regurgitation suggest that smaller relative changes in NT-proBNP are clinically meaningful in these patients. © 2015 American Society for Veterinary Clinical Pathology.
Sheikhbahaei, Sara; Mahdaviani, Behnaz; Abdollahi, Alireza; Nayeri, Fatemeh
2014-01-01
Context: Congenital hypothyroidism (CH), the most common etiology of preventable mental retardation in children, is estimated to be more prevalent among Asian population. Aims: Since thyroid function tests (TFTs) varied among different ages and geographical regions, in this study, the neonatal thyroid reference intervals in a healthy neonatal population is determined for the first time in Iran. Settings and Design: A cross-sectional study performed on 246 healthy term newborns aged between 2 days and 1 month. Materials and Methods: Blood samples were obtained by venipuncture from all subjects. The median, 2.5th, 5th, 95th, and 97.5th percentile of serum thyroid-stimulating hormone (TSH), as well as the total and free T4 were assessed among different age groups. Statistical Analysis Used: Predictive Analytics Software (PASW Statistics 18) was used for the analysis. Results: Serum TSH, total and free T4 concentration peaked in 5th to 7th days of life, continued over 2 weeks, then decreased and started reaching to adult reference range. A significant negative correlation between age and serum concentration of TSH (P = 0.02), total T4 (P = 0.01) and free T4 (P = 0.01) was found. Conclusion: This study yielded fairly different values for TFTs compared compared values found in other countries and also different from values reported for laboratory kits we used. These differences were assumed to be due to variations in ethnicity, age, and laboratory methods used. Due to the lack of international standardization, conducting multicenter studies helps in making a more precise evaluation of thyroid status in neonates. PMID:24701428
Determination of δ18O and δ15N in Nitrate
Revesz, K.; Böhlke, J.K.; Yoshinari, T.
1997-01-01
The analyses of both O and N isotopic compositions of nitrate have many potential applications in studies of nitrate sources and reactions in hydrology, oceanography, and atmospheric chemistry, but simple and precise methods for these analyses have yet to be developed. Testing of a new method involving reaction of potassium nitrate with catalyzed graphite (C + Pd + Au) at 520 °C resulted in quantitative recovery of N and O from nitrate as free CO2, K2CO3, and N2. The δ18O values of nitrate reference materials were obtained by analyzing both the CO2 and K2CO3 from catalyzed graphite combustion. Provisional values of δ18OVSMOW for the internationally distributed KNO3 reference materials IAEA-N3 and USGS-32 were both equal to +22.7 ± 0.5‰. Because the fraction of free CO2 and the isotopic fractionation factor between CO2 and K2CO3 were constant in the combustion products, the δ18O value of KNO3 could be calculated from measurements of the δ18O of free CO2. Thus, δ18OKNO3 = aδ18Ofree CO2 − b, where a and b were equal to 0.9967 and 3.3, respectively, for the specific conditions of the experiments. The catalyzed graphite combustion method can be used to determine δ18O of KNO3 from measurements of δ18O of free CO2 with reproducibility on the order of ±0.2‰ or better if local reference materials are prepared and analyzed with the samples. Reproducibility of δ15N was ±0.1‰ after trace amounts of CO were removed.
Horton, Lindsey M.; Mortensen, Mary E.; Iossifova, Yulia; Wald, Marlena M.; Burgess, Paula
2013-01-01
Arsenic, cadmium, lead, and mercury present potential health risks to children who are exposed through inhalation or ingestion. Emerging Market countries experience rapid industrial development that may coincide with the increased release of these metals into the environment. A literature review was conducted for English language articles from the 21st century on pediatric exposures to arsenic, cadmium, lead, and mercury in the International Monetary Fund's (IMF) top 10 Emerging Market countries: Brazil, China, India, Indonesia, Mexico, Poland, Russia, South Korea, Taiwan, and Turkey. Seventy-six peer-reviewed, published studies on pediatric exposure to metals met the inclusion criteria. The reported concentrations of metals in blood and urine from these studies were generally higher than US reference values, and many studies identified adverse health effects associated with metals exposure. Evidence of exposure to metals in the pediatric population of these Emerging Market countries demonstrates a need for interventions to reduce exposure and efforts to establish country-specific reference values through surveillance or biomonitoring. The findings from review of these 10 countries also suggest the need for country-specific public health policies and clinician education in Emerging Markets. PMID:23365584
Arkhipkin, A A; Liang, O V; Kochetov, A G
2014-10-01
The study was carried out to determine the prognostic value of alpha-fetoprotein in development of lethal outcome and degree of functional rehabilitation of patients with ischemic stroke. The sampling included 216 patients in acute period of ischemic stroke. At the first day of development of disease they were measured the level of human alpha-fetoprotein. At the second day of disease patients were evaluated the degree of functional rehabilitation and the rate of lethal outcomes was calculated. Previously, the reference interval for alpha-fetoprotein was calculated according the guidelines of the International federation of clinical chemistry and national standard. The reference interval amounted to 0.59-3.78 mE/l. The study results demonstrated that low level of alpha-fetoprotein is related to higher risk of lethal outcome (SE=1.7, p=0.012). The increasing of level of alpha-fetoprotein over mentioned threshold value statistically significant increases probability of survival of patients. The further increasing more than 2.28 mE/l is related to subsequent good functional rehabilitation according the modifies Rankine scale (SE=1.4, p=0.001) and Barthel index (SE=1.49, p<0.001).
Automation of film densitometry for application in personal monitoring.
Taheri, M; Movafeghi, A; Rastkhah, N
2011-03-01
In this research work, a semi-automatic densitometry system has been developed for large-scale monitoring services by use of film badge dosemeters. The system consists of a charge-coupled device (CCD)-based scanner that can scan optical densities (ODs) up to 4.2, a computer vision algorithm to improve the quality of digitised films and an analyser program to calculate the necessary information, e.g. the mean OD of region of interest and radiation doses. For calibration of the system, two reference films were used. The Microtek scanner International Color Consortium (ICC) profiler is applied for determining the colour attributes of the scanner accurately and a reference of the density step tablet, Bundesanstalt für Materialforschung und-prüfung (BAM) is used for calibrating the automatic conversion of gray-level values to OD values in the range of 0.2-4.0 OD. The system contributes to achieve more objectives and reliable results. So by applying this system, we can digitise a set of 20 films at once and calculate their relative doses less than about 4 min, and meanwhile it causes to avoid disadvantages of manual process and to enhance the accuracy of dosimetry.
Horton, Lindsey M; Mortensen, Mary E; Iossifova, Yulia; Wald, Marlena M; Burgess, Paula
2013-01-01
Arsenic, cadmium, lead, and mercury present potential health risks to children who are exposed through inhalation or ingestion. Emerging Market countries experience rapid industrial development that may coincide with the increased release of these metals into the environment. A literature review was conducted for English language articles from the 21st century on pediatric exposures to arsenic, cadmium, lead, and mercury in the International Monetary Fund's (IMF) top 10 Emerging Market countries: Brazil, China, India, Indonesia, Mexico, Poland, Russia, South Korea, Taiwan, and Turkey. Seventy-six peer-reviewed, published studies on pediatric exposure to metals met the inclusion criteria. The reported concentrations of metals in blood and urine from these studies were generally higher than US reference values, and many studies identified adverse health effects associated with metals exposure. Evidence of exposure to metals in the pediatric population of these Emerging Market countries demonstrates a need for interventions to reduce exposure and efforts to establish country-specific reference values through surveillance or biomonitoring. The findings from review of these 10 countries also suggest the need for country-specific public health policies and clinician education in Emerging Markets.
Experimental Study of Radiation Efficiency from an Ingested Source inside a Human Body Model*.
Chan, Yawen; -H Meng, Max; Wu, K-L; Wang, Xiaona
2005-01-01
The attenuation of human body trunk at frequency range of 100MHz to 6GHz from an internal source was estimated using a simplified experimental model. Antennas were placed in the model which was filled with distilled water, 0.9% NaCl saline solution, and porcine body tissue alternately to determine the attenuation of the system. Saline has greater attenuation than water due to its higher conductivity, while porcine body tissue has attenuation bounded by saline solution and water. Estimated attenuation at the four ISM bands, 434MHz, 915MHz, 2.45GHz and 5.8GHz were given and all of these bands satisfied the safety and sensitivity requirements of a biomedical telemetry system. 915MHz and 2.45GHz are good choices for the wireless link because of their relatively larger electrical size of RF components such as antenna. In addition, with the growth in wireless LAN and Bluetooth technology, miniaturized antennas, camera modules, and other RF devices have been developed which can be employed in biomedical ingested or implanted devices. This paper gives a reference of attenuation values of a human body trunk of average size. It should be noted that the attenuation values can be different for different body size and different body composition, and therefore the values in this paper serves as a reference only.
Szymczak, Wiesław; Sobala, Wojciech; Wilczyńska, Urszula; Szeszenia-Dabrowska, Neonila
2003-01-01
The main goal of the study was to analyze thoroughly the results of a cohort study. Such an analysis renders it possible to eliminate certain neoplasms as those not related to the observed exposure. The cohort study was carried out in a group of workers, covering 11,342 persons (5472 men and 5870 women), employed for at least one year during the years 1945-1985 in a rubber footwear plant. The cohort study was continued until the end of December 1997. Of all the sites of malignant neoplasms observed in the cohort, significant, exposure-related excess mortality was found to be due to malignant neoplasms of larynx and lung in men, and malignant neoplasms of gallbladder and lung in women. For these neoplasms, the values of observed risk among those exposed were significantly higher than among non-exposed. Moreover, in a certain interval of employment duration, an increase in risk rates with increasing duration of employment under exposure was observed, which suggests the presence of dose-response relationship. For all these sites, a relevant trend was shown by the RR values calculated in relation to the group of persons non-exposed but employed in the same plant. The internal reference group used to calculate RR values allowed to eliminate the effect of confounding variables, which is not always possible when the general population is used as the reference group.
Advanced Life Support Research and Technology Development Metric: Fiscal Year 2003
NASA Technical Reports Server (NTRS)
Hanford, A. J.
2004-01-01
This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2003. As such, the values herein are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. The Metric is one of several measures employed by the National Aeronautics and Space Administration (NASA) to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). More specifically, the Metric is the ratio defined by the equivalent system mass (ESM) of a life support system for a specific mission using the ISS ECLSS technologies divided by the ESM for an equivalent life support system using the best ALS technologies. As defined, the Metric should increase in value as the ALS technologies become lighter, less power intensive, and require less volume. For Fiscal Year 2003, the Advanced Life Support Research and Technology Development Metric value is 1.47 for an Orbiting Research Facility and 1.36 for an Independent Exploration Mission.
Song, Ji Soo; Kwak, Hyo Sung; Byon, Jung Hee; Jin, Gong Yong
2017-05-01
To compare the apparent diffusion coefficient (ADC) of upper abdominal organs acquired at different time points, and to investigate the usefulness of normalization. We retrospectively evaluated 58 patients who underwent three rounds of magnetic resonance (MR) imaging including diffusion-weighted imaging of the upper abdomen. MR examinations were performed using three different 3.0 Tesla (T) and one 1.5T systems, with variable b value combinations and respiratory motion compensation techniques. The ADC values of the upper abdominal organs from three different time points were analyzed, using the ADC values of the paraspinal muscle (ADC psm ) and spleen (ADC spleen ) for normalization. Intraclass correlation coefficients (ICC) and comparison of dependent ICCs were used for statistical analysis. The ICCs of the original ADC and ADC psm showed fair to substantial agreement, while ADC spleen showed substantial to almost perfect agreement. The ICC of ADC spleen of all anatomical regions showed less variability compared with that of the original ADC (P < 0.005). Normalized ADC using the spleen as a reference organ significantly decreased variability in measurement of the upper abdominal organs in different MR systems at different time points and could be regarded as an imaging biomarker for future multicenter, longitudinal studies. 5 J. MAGN. RESON. IMAGING 2017;45:1494-1501. © 2016 International Society for Magnetic Resonance in Medicine.
Tests for qualitative treatment-by-centre interaction using a 'pushback' procedure.
Ciminera, J L; Heyse, J F; Nguyen, H H; Tukey, J W
1993-06-15
In multicentre clinical trials using a common protocol, the centres are usually regarded as being a fixed factor, thus allowing any treatment-by-centre interaction to be omitted from the error term for the effect of treatment. However, we feel it necessary to use the treatment-by-centre interaction as the error term if there is substantial evidence that the interaction with centres is qualitative instead of quantitative. To make allowance for the estimated uncertainties of the centre means, we propose choosing a reference value (for example, the median of the ordered array of centre means) and converting the individual centre results into standardized deviations from the reference value. The deviations are then reordered, and the results 'pushed back' by amounts appropriate for the corresponding order statistics in a sample from the relevant distribution. The pushed-back standardized deviations are then restored to the original scale. The appearance of opposite signs among the destandardized values for the various centres is then taken as 'substantial evidence' of qualitative interaction. Procedures are presented using, in any combination: (i) Gaussian, or Student's t-distribution; (ii) order-statistic medians or outward 90 per cent points of the corresponding order statistic distributions; (iii) pooling or grouping and pooling the internally estimated standard deviations of the centre means. The use of the least conservative combination--Student's t, outward 90 per cent points, grouping and pooling--is recommended.
Missed nursing care: a concept analysis.
Kalisch, Beatrice J; Landstrom, Gay L; Hinshaw, Ada Sue
2009-07-01
This paper is a report of the analysis of the concept of missed nursing care. According to patient safety literature, missed nursing care is an error of omission. This concept has been conspicuously absent in quality and patient safety literature, with individual aspects of nursing care left undone given only occasional mention. An 8-step method of concept analysis - select concept, determine purpose, identify uses, define attributes, identify model case, describe related and contrary cases, identify antecedents and consequences and define empirical referents - was used to examine the concept of missed nursing care. The sources for the analysis were identified by systematic searches of the World Wide Web, MEDLINE, CINAHL and reference lists of related journal articles with a timeline of 1970 to April 2008. Missed nursing care, conceptualized within the Missed Nursing Care Model, is defined as any aspect of required patient care that is omitted (either in part or in whole) or delayed. Various attribute categories reported by nurses in acute care settings contribute to missed nursing care: (1) antecedents that catalyse the need for a decision about priorities; (2) elements of the nursing process and (3) internal perceptions and values of the nurse. Multiple elements in the nursing environment and internal to nurses influence whether needed nursing care is provided. Missed care as conceptualized within the Missed Care Model is a universal phenomenon. The concept is expected to occur across all cultures and countries, thus being international in scope.
USDA-ARS?s Scientific Manuscript database
Workshops sponsored by the Institute of Medicine (IOM) and the World Health Organization (WHO) suggested that incorporating systematic reviews into the process of updating nutrient reference values would enhance the transparency of the process. The IOM issues the Dietary Reference Intake values (DR...
[Recent researching progress of Lepidium meyenii (Maca)].
Zhou, Yan-yan; Zhao, Hai-yu; Si, Nan; Wang, Hong-jie; Gian, Bao-lin
2015-12-01
Maca as one of the star products in the international health care market in recent years, had a wide range of application value and promoted to all over the world. However, the basic research of Maca was not deep, lack of systematic and clear efficacy studies. Market products hype its aphrodisiac effect, which greatly impact more systematic in-depth research and exploration. Therefore, this paper briefly summarizes advance research in recent years including the status quo of the resources, growth cultivation, phytochemical, pharmacological effect and other aspects, which can provide reference for rational development and utilization of Maca.
Integrated Baseline Review (IBR) Handbook
NASA Technical Reports Server (NTRS)
2013-01-01
An Integrated Baseline Review (IBR) is a review of a supplier?s Performance Measurement Baseline (PMB). It is conducted by Program/Project Managers and their technical staffs on contracts and in-house work requiring compliance with NASA Earned Value Management System (EVMS) policy as defined in program/project policy, NPR 7120.5, or in NASA Federal Acquisition Regulations. The IBR Handbook may also be of use to those responsible for preparing the Terms of Reference for internal project reviews. While risks may be identified and actions tracked as a result of the IBR, it is important to note that an IBR cannot be failed.
In Situ Preservation of Historic Spacecraft
NASA Astrophysics Data System (ADS)
Barclay, R.; Brooks, R.
The loss of the Mir space station is shown to symbolize a new consciousness of the value of space artefacts. The reasons why such artefacts as Mir become historic objects worthy of preservation are examined. Preservation of space vehicles in situ is discussed, with particular reference to safety, monitoring and long term costs. An argument is made for a wider definition for World Heritage designations to include material beyond the surface of the Earth, and for international bodies to assess, monitor and oversee these projects. Such heritage sites are seen as an economic driver for the development of space tourism in the 21st century.
Rep. Reed, Tom [R-NY-23
2018-05-22
House - 05/22/2018 Referred to the Committee on Ways and Means, and in addition to the Committee on Education and the Workforce, for a period to be subsequently determined by the Speaker, in each case for consideration of such provisions as fall within the jurisdiction of the... (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Formulas for precession. [motion of mean equator
NASA Technical Reports Server (NTRS)
Kinoshita, H.
1975-01-01
Literal expressions for the precessional motion of the mean equator referred to an arbitrary epoch are constructed. Their numerical representations, based on numerical values recommended at the working meeting of the International Astronomical Union Commission held in Washington in September 1974, are obtained. In constructing the equations of motion, the second-order secular perturbation and the secular perturbation due to the long-periodic terms in the motions of the moon and the sun are taken into account. These perturbations contribute more to the motion of the mean equator than does the term due to the secular perturbation of the orbital eccentricity of the sun.
Properties of the internal clock.
Church, R M
1984-01-01
Evidence has been cited for the following properties of the parts of the psychological process used for timing intervals: The pacemaker has a mean rate that can be varied by drugs, diet, and stress. The switch has a latency to operate and it can be operated in various modes, such as run, stop, and reset. The accumulator times up, in absolute, arithmetic units. Working memory can be reset on command or, after lesions have been created in the fimbria fornix, when there is a gap in a signal. The transformation from the accumulator to reference memory is done with a multiplicative constant that is affected by drugs, lesions, and individual differences. The comparator uses a ratio between the value in the accumulator (or working memory) and reference memory. Finally, there must be multiple switch-accumulator modules to handle simultaneous temporal processing; and the psychological timing process may be used on some occasions and not on others.
A model of geomagnetic secular variation for 1980-1983
Peddie, N.W.; Zunde, A.K.
1987-01-01
We developed an updated model of the secular variation of the main geomagnetic field during 1980 through 1983 based on annual mean values for that interval from 148 worldwide magnetic observatories. The model consists of a series of 80 spherical harmonics, up to and including those of degree and order 8. We used it to form a proposal for the 1985 revision of the International Geomagnetic Reference Field (IGRF). Comparison of the new model, whose mean epoch is approximately 1982.0, with the Provisional Geomagnetic Reference Field for 1975-1980 (PGRF 1975), indicates that the moment of the centered-dipole part of the geomagnetic field is now decreasing faster than it was 5 years ago. The rate (in field units) indicated by PGRF 1975 was about -25 nT a-1, while for the new model it is -28 nT a-1. ?? 1987.
NASA Astrophysics Data System (ADS)
Spicakova, H.; Plank, L.; Nilsson, T.; Böhm, J.; Schuh, H.
2011-07-01
The Vienna VLBI Software (VieVS) has been developed at the Institute of Geodesy and Geophysics at TU Vienna since 2008. In this presentation, we present the module Vie_glob which is the part of VieVS that allows the parameter estimation from multiple VLBI sessions in a so-called global solution. We focus on the determination of the terrestrial reference frame (TRF) using all suitable VLBI sessions since 1984. We compare different analysis options like the choice of loading corrections or of one of the models for the tropospheric delays. The effect of atmosphere loading corrections on station heights if neglected at observation level will be shown. Time series of station positions (using a previously determined TRF as a priori values) are presented and compared to other estimates of site positions from individual IVS (International VLBI Service for Geodesy and Astrometry) Analysis Centers.
Patel, Samir
2015-03-01
Health care is in a state of transition, shifting from volume-based success to value-based success. Hospital executives and referring physicians often do not understand the total value a radiology group provides. A template for easy, cost-effective implementation in clinical practice for most radiology groups to demonstrate the value they provide to their clients (patients, physicians, health care executives) has not been well described. A value management program was developed to document all of the value-added activities performed by on-site radiologists, quantify them in terms of time spent on each activity (investment), and present the benefits to internal and external stakeholders (outcomes). The radiology value-added matrix is the platform from which value-added activities are categorized and synthesized into a template for defining investments and outcomes. The value management program was first implemented systemwide in 2013. Across all serviced locations, 9,931.75 hours were invested. An annual executive summary report template demonstrating outcomes is given to clients. The mean and median individual value-added hours per radiologist were 134.52 and 113.33, respectively. If this program were extrapolated to the entire field of radiology, approximately 30,000 radiologists, this would have resulted in 10,641,161 uncompensated value-added hours documented in 2013, with an estimated economic value of $2.21 billion. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Lee, Naery; Seo, Ji Suk; Kim, Jae Ok; Ban, Sang Ja
2017-05-01
Since the 1st Korean national biological reference standard for factor (F)VIII concentrate, established in 2001, has shown declining potency, we conducted this study to replace this standard with a 2nd Korean national biological reference standard for blood coagulation FVIII concentrate. The candidate materials for the 2nd standard were prepared in 8000 vials with 10 IU/ml of target potency, according to the approved manufacturing process of blood coagulation Factor VIII:C Monoclonal Antibody-purified, Freeze-dried Human Blood Coagulation Factor VIII:C. Potency was evaluated by one-stage clotting and chromogenic methods and the stability was confirmed to meet the specifications during a period of 73 months. Since the potencies obtained by the two methods differed significantly (P < 0.015), the values were determined separately according to the geometric means (8.9 and 7.4 IU/vial, respectively). The geometric coefficients of interlaboratory variability were 3.4% and 7.6% by the one-stage clotting and chromogenic assays, respectively. Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Dumez, Birgit; Van Damme, Karel; Casteleyn, Ludwine
2008-06-05
Assessment of ethical aspects and authorization by ethics committees have become a major constraint for health research including human subjects. Ethical reference values often are extrapolated from clinical settings, where emphasis lies on decisional autonomy and protection of individual's privacy. The question rises if this set of values used in clinical research can be considered as relevant references for HBM research, which is at the basis of public health surveillance. Current and future research activities using human biomarkers are facing new challenges and expectancies on sensitive socio-ethical issues. Reflection is needed on the necessity to balance individual rights against public interest. In addition, many HBM research programs require international collaboration. Domestic legislation is not always easily applicable in international projects. Also, there seem to be considerable inconsistencies in ethical assessments of similar research activities between different countries and even within one country. All this is causing delay and putting the researcher in situations in which it is unclear how to act in accordance with necessary legal requirements. Therefore, analysis of ethical practices and their consequences for HBM research is needed.This analysis will be performed by a bottom-up approach, based on a methodology for comparative analysis of determinants in ethical reasoning, allowing taking into account different social, cultural, political and historical traditions, in view of safeguarding common EU values. Based on information collected in real life complexity, paradigm cases and virtual case scenarios will be developed and discussed with relevant stakeholders to openly discuss possible obstacles and to identify options for improvement in regulation. The material collected will allow developing an ethical framework which may constitute the basis for a more harmonized and consistent socio-ethical and legal approach. This will not only increase the possibilities for comparison between data generated but may also allow for more equality in the protection of the rights of European citizens and establish trustful relationships between science and society, based on firmly rooted ethical values within the EU legislative framework.These considerations outline part of the research on legal, socio-ethical and communication aspects of HBM within the scope of ECNIS (NoE) and NewGeneris (IP).
Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C
2016-05-01
Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. Twenty-five client-owned dogs with PDA. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and decreases to normal values in short axis (circumferential, radial, and transversal S/SR decreased to normal reference range). Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Dumez, Birgit; Van Damme, Karel; Casteleyn, Ludwine
2008-01-01
Assessment of ethical aspects and authorization by ethics committees have become a major constraint for health research including human subjects. Ethical reference values often are extrapolated from clinical settings, where emphasis lies on decisional autonomy and protection of individual's privacy. The question rises if this set of values used in clinical research can be considered as relevant references for HBM research, which is at the basis of public health surveillance. Current and future research activities using human biomarkers are facing new challenges and expectancies on sensitive socio-ethical issues. Reflection is needed on the necessity to balance individual rights against public interest. In addition, many HBM research programs require international collaboration. Domestic legislation is not always easily applicable in international projects. Also, there seem to be considerable inconsistencies in ethical assessments of similar research activities between different countries and even within one country. All this is causing delay and putting the researcher in situations in which it is unclear how to act in accordance with necessary legal requirements. Therefore, analysis of ethical practices and their consequences for HBM research is needed. This analysis will be performed by a bottom-up approach, based on a methodology for comparative analysis of determinants in ethical reasoning, allowing taking into account different social, cultural, political and historical traditions, in view of safeguarding common EU values. Based on information collected in real life complexity, paradigm cases and virtual case scenarios will be developed and discussed with relevant stakeholders to openly discuss possible obstacles and to identify options for improvement in regulation. The material collected will allow developing an ethical framework which may constitute the basis for a more harmonized and consistent socio-ethical and legal approach. This will not only increase the possibilities for comparison between data generated but may also allow for more equality in the protection of the rights of European citizens and establish trustful relationships between science and society, based on firmly rooted ethical values within the EU legislative framework. These considerations outline part of the research on legal, socio-ethical and communication aspects of HBM within the scope of ECNIS (NoE) and NewGeneris (IP). PMID:18541073
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
NASA Astrophysics Data System (ADS)
Pignalberi, A.; Pezzopane, M.; Rizzi, R.; Galkin, I.
2018-01-01
The first part of this paper reviews methods using effective solar indices to update a background ionospheric model focusing on those employing the Kriging method to perform the spatial interpolation. Then, it proposes a method to update the International Reference Ionosphere (IRI) model through the assimilation of data collected by a European ionosonde network. The method, called International Reference Ionosphere UPdate (IRI UP), that can potentially operate in real time, is mathematically described and validated for the period 9-25 March 2015 (a time window including the well-known St. Patrick storm occurred on 17 March), using IRI and IRI Real Time Assimilative Model (IRTAM) models as the reference. It relies on foF2 and M(3000)F2 ionospheric characteristics, recorded routinely by a network of 12 European ionosonde stations, which are used to calculate for each station effective values of IRI indices IG_{12} and R_{12} (identified as IG_{{12{eff}}} and R_{{12{eff}}}); then, starting from this discrete dataset of values, two-dimensional (2D) maps of IG_{{12{eff}}} and R_{{12{eff}}} are generated through the universal Kriging method. Five variogram models are proposed and tested statistically to select the best performer for each effective index. Then, computed maps of IG_{{12{eff}}} and R_{{12{eff}}} are used in the IRI model to synthesize updated values of foF2 and hmF2. To evaluate the ability of the proposed method to reproduce rapid local changes that are common under disturbed conditions, quality metrics are calculated for two test stations whose measurements were not assimilated in IRI UP, Fairford (51.7°N, 1.5°W) and San Vito (40.6°N, 17.8°E), for IRI, IRI UP, and IRTAM models. The proposed method turns out to be very effective under highly disturbed conditions, with significant improvements of the foF2 representation and noticeable improvements of the hmF2 one. Important improvements have been verified also for quiet and moderately disturbed conditions. A visual analysis of foF2 and hmF2 maps highlights the ability of the IRI UP method to catch small-scale changes occurring under disturbed conditions which are not seen by IRI.
Coplen, Tyler B.
2010-01-01
Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.
NASA Astrophysics Data System (ADS)
Correia, Victor; Allington, Ruth; Keane, Christopher
2016-04-01
A secure supply of raw materials is a European priority that extends beyond country borders and national policies. Recent European initiatives have pioneered the development of an EU strategy on raw materials emphasizing the concept of the "added value chain", which continues to pursue the three pillar strategy to: (1) ensure the fair and sustainable supply of raw materials from international markets, promoting international cooperation with developed and developing countries; (2) foster sustainable supply of raw materials from European sources, and (3) reduce consumption of primary raw materials by increasing resource efficiency and promoting recycling. This contribution presents the Horizon 2020 funded project INTRAW, the objective of which is to establish the European Union's International Observatory for Raw Materials. The creation and maintenance of the European Union's International Observatory for Raw Materials is designed to have a strong impact in two dimensions: 1. To narrow the existing gap in aspects of the raw materials knowledge infrastructure in the EU by providing a link with the same knowledge infrastructure in technologically advanced reference countries. This should contribute to the harmonization of mineral policies all over the EU, by providing data that enables evidence-based policies and appropriate, cost-effective management, planning and adaptation decisions by the public sector. This will benefit businesses, industry and society. The Observatory will also provide to policy makers in the EU and its Member States the data they need to facilitate discussion in multilateral forums. 2. To enable a better alignment of the R&I activities among the individual EU members and international cooperation countries AND between the European Union and international cooperation countries by boosting synergies with international research and innovation programmes. This way the EU's role and scientific capabilities in the raw materials area will be reinforced in the mid-term, and the conditions for sustainable access and supply of raw materials in the EU will benefit from the international cooperation. The authors will describe the key stages of the INTRAW project and explain how it aims to establish (and promote the continuation of) international cooperation at every stage of the raw materials value chain and to build a repository of information and analysis to support the development and strengthening of EU raw materials strategies. Key elements of the value chain upon which the project focuses are: industry and trade; education and outreach; and research and innovation. The roles of geoscientists in delivering the aims and objectives of INTRAW will be emphasised.
Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M
2006-08-31
International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.
ERIC Educational Resources Information Center
Leach, Jamie; Howe, Nina; DeHart, Ganie
2017-01-01
The present study investigated children's internal state language during play with their sibling and friend across early and middle childhood. Specifically, the category type of internal state language (e.g., cognitions and goals), referent (e.g., own and other), and associations with children's birth order were examined. A total of 65 (T1: Time…
The International Geomagnetic Reference Field: the twelfth generation
NASA Astrophysics Data System (ADS)
Thebault, Erwan; Finlay, Christopher; The IGRF Working Group
2015-04-01
The IGRF is an internationally-agreed reference model of the Earth's magnetic field produced under the auspices of the International Association of Geomagnetism and Aeronomy. The IGRF-12 is the latest update of this well-known model which is used each year by many thousands of users for both industrial and scientific purposes. In October 2014, ten institutions worldwide have made contributions to the IGRF. These models were evaluated and the twelfth generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2014. In this presentation, we will report on the IGRF activities, briefly describe the candidate models, summarize the evaluation of models performed by different independent teams, show how the IGRF-12 models were calculated and finally discuss some of the main magnetic features of this new model.
Reference values for anxiety questionnaires: the Leiden Routine Outcome Monitoring Study.
Schulte-van Maaren, Yvonne W M; Giltay, Erik J; van Hemert, Albert M; Zitman, Frans G; de Waal, Margot W M; Carlier, Ingrid V E
2013-09-25
The monitoring of patients with an anxiety disorder can benefit from Routine Outcome Monitoring (ROM). As anxiety disorders differ in phenomenology, several anxiety questionnaires are included in ROM: Brief Scale for Anxiety (BSA), PADUA Inventory Revised (PI-R), Panic Appraisal Inventory (PAI), Penn State Worry Questionnaire (PSWQ), Worry Domains Questionnaire (WDQ), Social Interaction, Anxiety Scale (SIAS), Social Phobia Scale (SPS), and the Impact of Event Scale-Revised (IES-R). We aimed to generate reference values for both 'healthy' and 'clinically anxious' populations for these anxiety questionnaires. We included 1295 subjects from the general population (ROM reference-group) and 5066 psychiatric outpatients diagnosed with a specific anxiety disorder (ROM patient-group). The MINI was used as diagnostic device in both the ROM reference group and the ROM patient group. To define limits for one-sided reference intervals (95th percentile; P95) the outermost 5% of observations were used. Receiver Operating Characteristics (ROC) analyses were used to yield alternative cut-off values for the anxiety questionnaires. For the ROM reference-group the mean age was 40.3 years (SD=12.6), and for the ROM patient-group it was 36.5 years (SD=11.9). Females constituted 62.8% of the reference-group and 64.4% of the patient-group. P95 ROM reference group cut-off values for reference versus clinically anxious populations were 11 for the BSA, 43 for the PI-R, 37 for the PAI Anticipated Panic, 47 for the PAI Perceived Consequences, 65 for the PAI Perceived Self-efficacy, 66 for the PSWQ, 74 for the WDQ, 32 for the SIAS, 19 for the SPS, and 36 for IES-R. ROC analyses yielded slightly lower reference values. The discriminative power of all eight anxiety questionnaires was very high. Substantial non-response and limited generalizability. For eight anxiety questionnaires a comprehensive set of reference values was provided. Reference values were generally higher in women than in men, implying the use of gender-specific cut-off values. Each instrument can be offered to every patient with MAS disorders to make responsible decisions about continuing, changing or terminating therapy. © 2013 Elsevier B.V. All rights reserved.
Reference values of inspiratory spirometry for Finnish adults.
Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R
2018-03-07
Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.
International reference ionosphere 1990
NASA Technical Reports Server (NTRS)
Bilitza, Dieter; Rawer, K.; Bossy, L.; Kutiev, I.; Oyama, K.-I.; Leitinger, R.; Kazimirovsky, E.
1990-01-01
The International Reference Ionosphere 1990 (IRI-90) is described. IRI described monthly averages of the electron density, electron temperature, ion temperature, and ion composition in the altitude range from 50 to 1000 km for magnetically quiet conditions in the non-auroral ionosphere. The most important improvements and new developments are summarized.
Reference values of elements in human hair: a systematic review.
Mikulewicz, Marcin; Chojnacka, Katarzyna; Gedrange, Thomas; Górecki, Henryk
2013-11-01
The lack of systematic review on reference values of elements in human hair with the consideration of methodological approach. The absence of worldwide accepted and implemented universal reference ranges causes that hair mineral analysis has not become yet a reliable and useful method of assessment of nutritional status and exposure of individuals. Systematic review of reference values of elements in human hair. PubMed, ISI Web of Knowledge, Scopus. Humans, hair mineral analysis, elements or minerals, reference values, original studies. The number of studies screened and assessed for eligibility was 52. Eventually, included in the review were 5 papers. The studies report reference ranges for the content of elements in hair: macroelements, microelements, toxic elements and other elements. Reference ranges were elaborated for different populations in the years 2000-2012. The analytical methodology differed, in particular sample preparation, digestion and analysis (ICP-AES, ICP-MS). Consequently, the levels of hair minerals reported as reference values varied. It is necessary to elaborate the standard procedures and furtherly validate hair mineral analysis and deliver detailed methodology. Only then it would be possible to provide meaningful reference ranges and take advantage of the potential that lies in Hair Mineral Analysis as a medical diagnostic technique. Copyright © 2013 Elsevier B.V. All rights reserved.
Zainol, Murizal; Stoute, Julia; Almeida, Gabriela M.; Rapp, Alexander; Bowman, Karen J.; Jones, George D. D.
2009-01-01
The Comet assay (CA) is a sensitive/simple measure of genotoxicity. However, many features of CA contribute variability. To minimize these, we have introduced internal standard materials consisting of ‘reference’ cells which have their DNA substituted with BrdU. Using a fluorescent anti-BrdU antibody, plus an additional barrier filter, comets derived from these cells could be readily distinguished from the ‘test’-cell comets, present in the same gel. In experiments to evaluate the reference cell comets as external and internal standards, the reference and test cells were present in separate gels on the same slide or mixed together in the same gel, respectively, before their co-exposure to X-irradiation. Using the reference cell comets as internal standards led to substantial reductions in the coefficient of variation (CoV) for intra- and inter-experimental measures of comet formation and DNA damage repair; only minor reductions in CoV were noted when the reference and test cell comets were in separate gels. These studies indicate that differences between individual gels appreciably contribute to CA variation. Further studies using the reference cells as internal standards allowed greater significance to be obtained between groups of replicate samples. Ultimately, we anticipate that development will deliver robust quality assurance materials for CA. PMID:19828597
The gravity field observations and products at IGFS
NASA Astrophysics Data System (ADS)
Barzaghi, Riccardo; Vergos, George; Bonvalot, Sylvain; Barthelmes, Franz; Reguzzoni, Mirko; Wziontek, Hartmut; Kelly, Kevin
2017-04-01
The International Gravity Field Service (IGFS) is a service of the International Association of Geodesy (IAG) that was established in 2003 at the IAG/IUGG General Assembly in Sapporo (Japan). This service aims at coordinating the actions of the IAG services related to the Earth gravity field, i.e. the Bureau Gravimétrique International (BGI), the International Service for the Geoid (ISG), the International Geodynamics and Earth Tides Service (IGETS), the International Center for Global Earth Models (ICGEM) and the International Digital Elevation Model Service (IDEMS). Also, via its Central Bureau hosted at the Aristotle University of Thessaloniki (Greece), IGFS provides a link to the Global Geodetic Observing System (GGOS) bureaus in order to communicate their requirements and recommendations to the IGFS-Centers. In this work, a presentation is given on the recent activities of the service, namely those related to the contributions to the implementation of: the International Height Reference System/Frame; the Global Geodetic Reference System/Frame; the new Global Absolute Gravity Reference System/Frame. Particularly, the impact that these activities have in improving the estimation of the Earth's gravity field, either at global and local scale, is highlighted also in the framework of GGOS.
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
Li, Haisen S; Zhong, Hualiang; Kim, Jinkoo; Glide-Hurst, Carri; Gulam, Misbah; Nurushev, Teamour S; Chetty, Indrin J
2014-01-06
The direct dose mapping (DDM) and energy/mass transfer (EMT) mapping are two essential algorithms for accumulating the dose from different anatomic phases to the reference phase when there is organ motion or tumor/tissue deformation during the delivery of radiation therapy. DDM is based on interpolation of the dose values from one dose grid to another and thus lacks rigor in defining the dose when there are multiple dose values mapped to one dose voxel in the reference phase due to tissue/tumor deformation. On the other hand, EMT counts the total energy and mass transferred to each voxel in the reference phase and calculates the dose by dividing the energy by mass. Therefore it is based on fundamentally sound physics principles. In this study, we implemented the two algorithms and integrated them within the Eclipse treatment planning system. We then compared the clinical dosimetric difference between the two algorithms for ten lung cancer patients receiving stereotactic radiosurgery treatment, by accumulating the delivered dose to the end-of-exhale (EE) phase. Specifically, the respiratory period was divided into ten phases and the dose to each phase was calculated and mapped to the EE phase and then accumulated. The displacement vector field generated by Demons-based registration of the source and reference images was used to transfer the dose and energy. The DDM and EMT algorithms produced noticeably different cumulative dose in the regions with sharp mass density variations and/or high dose gradients. For the planning target volume (PTV) and internal target volume (ITV) minimum dose, the difference was up to 11% and 4% respectively. This suggests that DDM might not be adequate for obtaining an accurate dose distribution of the cumulative plan, instead, EMT should be considered.
Abràmoff, Michael David; Lou, Yiyue; Erginay, Ali; Clarida, Warren; Amelon, Ryan; Folk, James C; Niemeijer, Meindert
2016-10-01
To compare performance of a deep-learning enhanced algorithm for automated detection of diabetic retinopathy (DR), to the previously published performance of that algorithm, the Iowa Detection Program (IDP)-without deep learning components-on the same publicly available set of fundus images and previously reported consensus reference standard set, by three US Board certified retinal specialists. We used the previously reported consensus reference standard of referable DR (rDR), defined as International Clinical Classification of Diabetic Retinopathy moderate, severe nonproliferative (NPDR), proliferative DR, and/or macular edema (ME). Neither Messidor-2 images, nor the three retinal specialists setting the Messidor-2 reference standard were used for training IDx-DR version X2.1. Sensitivity, specificity, negative predictive value, area under the curve (AUC), and their confidence intervals (CIs) were calculated. Sensitivity was 96.8% (95% CI: 93.3%-98.8%), specificity was 87.0% (95% CI: 84.2%-89.4%), with 6/874 false negatives, resulting in a negative predictive value of 99.0% (95% CI: 97.8%-99.6%). No cases of severe NPDR, PDR, or ME were missed. The AUC was 0.980 (95% CI: 0.968-0.992). Sensitivity was not statistically different from published IDP sensitivity, which had a CI of 94.4% to 99.3%, but specificity was significantly better than the published IDP specificity CI of 55.7% to 63.0%. A deep-learning enhanced algorithm for the automated detection of DR, achieves significantly better performance than a previously reported, otherwise essentially identical, algorithm that does not employ deep learning. Deep learning enhanced algorithms have the potential to improve the efficiency of DR screening, and thereby to prevent visual loss and blindness from this devastating disease.
Doyon, Anke; Kracht, Daniela; Bayazit, Aysun K; Deveci, Murat; Duzova, Ali; Krmar, Rafael T; Litwin, Mieczyslaw; Niemirska, Anna; Oguz, Berna; Schmidt, Bernhard M W; Sözeri, Betul; Querfeld, Uwe; Melk, Anette; Schaefer, Franz; Wühl, Elke
2013-09-01
Carotid intima-media thickness (cIMT) and carotid artery distensibility are reliable screening methods for vascular alterations and the assessment of cardiovascular risk in adult and pediatric cohorts. We sought to establish an international reference data set for the childhood and adolescence period and explore the impact of developmental changes in body dimensions and blood pressure (BP) on carotid wall thickness and elasticity. cIMT, the distensibility coefficient, the incremental modulus of elasticity, and the stiffness index β were assessed in 1155 children aged 6 to 18 years and sex-specific reference charts normalized to age or height were constructed from 1051 nonobese and nonhypertensive children. The role of body dimensions, BP, and family history, as well as the association between cIMT and distensibility, was investigated. cIMT increased and distensibility decreased with age, height, body mass index, and BP. A significant sex difference was apparent from the age of 15 years. Age- and height-normalized cIMT and distensibility values differed in children who are short or tall for their age. By stepwise multivariate analysis, standardized systolic BP and body mass index were independently positively associated with cIMT SD scores (SDS). Systolic BP SDS independently predicted all distensibility measures. Distensibility coefficient SDS was negatively and β SDS positively associated with cIMT SDS, whereas incremental modulus of elasticity was independent of cIMT. Morphological and functional aspects of the common carotid artery are particularly influenced by age, body dimensions, and BP. The reference charts established in this study allow to accurately compare vascular phenotypes of children with chronic conditions with those of healthy children.
NASA Astrophysics Data System (ADS)
Li, Haisen S.; Zhong, Hualiang; Kim, Jinkoo; Glide-Hurst, Carri; Gulam, Misbah; Nurushev, Teamour S.; Chetty, Indrin J.
2014-01-01
The direct dose mapping (DDM) and energy/mass transfer (EMT) mapping are two essential algorithms for accumulating the dose from different anatomic phases to the reference phase when there is organ motion or tumor/tissue deformation during the delivery of radiation therapy. DDM is based on interpolation of the dose values from one dose grid to another and thus lacks rigor in defining the dose when there are multiple dose values mapped to one dose voxel in the reference phase due to tissue/tumor deformation. On the other hand, EMT counts the total energy and mass transferred to each voxel in the reference phase and calculates the dose by dividing the energy by mass. Therefore it is based on fundamentally sound physics principles. In this study, we implemented the two algorithms and integrated them within the Eclipse treatment planning system. We then compared the clinical dosimetric difference between the two algorithms for ten lung cancer patients receiving stereotactic radiosurgery treatment, by accumulating the delivered dose to the end-of-exhale (EE) phase. Specifically, the respiratory period was divided into ten phases and the dose to each phase was calculated and mapped to the EE phase and then accumulated. The displacement vector field generated by Demons-based registration of the source and reference images was used to transfer the dose and energy. The DDM and EMT algorithms produced noticeably different cumulative dose in the regions with sharp mass density variations and/or high dose gradients. For the planning target volume (PTV) and internal target volume (ITV) minimum dose, the difference was up to 11% and 4% respectively. This suggests that DDM might not be adequate for obtaining an accurate dose distribution of the cumulative plan, instead, EMT should be considered.
Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang
2017-10-11
This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.
Radon Levels in Indoor Environments of the University Hospital in Bari-Apulia Region Southern Italy
Fucilli, Fulvio; Cavone, Domenica; De Maria, Luigi; Birtolo, Francesco; Ferri, Giovanni Maria; Soleo, Leonardo
2018-01-01
Since 1988, the International Agency for Research on Cancer (IARC) has classified radon among the compounds for which there is scientific evidence of carcinogenicity for humans (group 1). The World Health Organization (WHO) recommends a reference radon level between 100 and 300 Bq/m3 for homes. The objective of this study is to measure the radon concentrations in 401 workplaces, different from the patient rooms, in 28 different buildings of the university hospital in Bari (Apulia region, Southern Italy) to evaluate the exposure of health care workers. Radon environmental sampling is performed over two consecutive six-month periods via the use of passive dosimeters of the CR-39 type. We find an average annual radon concentration expressed as median value of 48.0 Bq/m3 (range 6.5–388.0 Bq/m3) with a significant difference between the two six-month periods (median value: February/July 41.0 Bq/m3 vs. August/January 55.0 Bq/m3). An average concentration of radon lower than the WHO reference level (100 Bq/m3) is detected in 76.1% of monitored environments, while higher than 300 Bq/m3 only in the 0.9%. Most workplaces report radon concentrations within the WHO reference level, therefore, the risk to workers’ health deriving from occupational exposure to radon can be considered to be low. Nevertheless, the goal is to achieve near-zero exposures to protect workers’ health. PMID:29642436
Mossetti, Stefano; de Bartolo, Daniela; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina; Nava, Elisa
2017-04-01
International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Krata, Agnieszka; Vassileva, Emilia; Bulska, Ewa
2016-11-01
The analytical procedures for reference measurements of the total Hg and methyl mercury (MeHg) mass fractions at various concentration levels in marine biota samples, candidates for certified reference materials (oyster and clam Gafrarium tumidum), were evaluated. Two modes of application of isotope dilution inductively coupled plasma mass spectrometry method (ID ICP-MS), namely direct isotope dilution and species-specific isotope dilution analysis with the use of two different quantification mass spectrometry techniques were compared. The entire ID ICP-MS measurement procedure was described by mathematical modelling and the combined uncertainty of measurement results was estimated. All factors influencing the final results as well as isotopic equilibrium were systematically investigated. This included the procedural blank, the moisture content in the biota samples and all factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time and mass discrimination effects as well as the repeatability of measured isotopic ratios). Modelling of the entire measurement procedures and the use of appropriate certified reference materials enable to assure the traceability of obtained values to the International System of Units (SI): the mole or the kilogram. The total mass fraction of mercury in oyster and clam biota samples, after correction for moisture contents, was found to be: 21.1 (1.1) 10(-9) kg kg(-1) (U =5.1% relative, k=2) and 390.0 (9.4) 10(-9) kg kg(-1) (U=2.4% relative, k=2), respectively. For the determination of mercury being present as methyl mercury, the non-chromatographic separation on anion-exchange resin AG1-X8 of the blended samples was applied. The content of MeHg (as Hg) in oyster sample was found: 4.81 (24) 10(-9)kgkg(-1) (U=5.0%, k=2) and 4.84 (21) 10(-9)kgkg(-1) (U=4.3%, k=2) with the use of quadrupole (ICP QMS) or sector field (ICP SFMS) inductively coupled plasma mass spectrometers, respectively. In the case of clam sample, the concentration of MeHg (as Hg) was found to be: 61.0 (2.3) 10(-)(9)kgkg(-1) (U=3.8%, k=2) and 61.3 (2.2) 10(-)(9)kgkg(-1) (U=3.6%, k=2), respectively. The mass fractions for total Hg and MeHg determined in this study were used as a contribution of the International Atomic Energy Agency (IAEA) Environment Laboratories in the characterisation of the IAEA 461 and IAEA 470 certified reference materials. The obtained good agreement with the reference values further validated the methods developed in this study. Copyright © 2016 Elsevier B.V. All rights reserved.
International energy outlook 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-05-01
This International Energy Outlook presents historical data from 1970 to 1993 and EIA`s projections of energy consumption and carbon emissions through 2015 for 6 country groups. Prospects for individual fuels are discussed. Summary tables of the IEO96 world energy consumption, oil production, and carbon emissions projections are provided in Appendix A. The reference case projections of total foreign energy consumption and of natural gas, coal, and renewable energy were prepared using EIA`s World Energy Projection System (WEPS) model. Reference case projections of foreign oil production and consumption were prepared using the International Energy Module of the National Energy Modeling Systemmore » (NEMS). Nuclear consumption projections were derived from the International Nuclear Model, PC Version (PC-INM). Alternatively, nuclear capacity projections were developed using two methods: the lower reference case projections were based on analysts` knowledge of the nuclear programs in different countries; the upper reference case was generated by the World Integrated Nuclear Evaluation System (WINES)--a demand-driven model. In addition, the NEMS Coal Export Submodule (CES) was used to derive flows in international coal trade. As noted above, foreign projections of electricity demand are now projected as part of the WEPS. 64 figs., 62 tabs.« less
Qi, Haiping; Lorenz, Jennifer M.; Coplen, Tyler B.; Tarbox, Lauren V.; Mayer, Bernhard; Taylor, Steve
2014-01-01
RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "
Zaid, Abdel Naser; Al Ramahi, Rowa’; Bustami, Rana; Mousa, Ayman; Khasawneh, Sewar
2015-01-01
Objective The aim of this study was to evaluate the bioequivalence of two drug products, generic clopidogrel bisulfate 75 mg film-coated tablets versus the reference Plavix® clopidogrel bisulfate 75 mg film-coated tablets. Methods Bioequivalence of tablets was tested by comparisons against the reference brand product in accordance with the requirements of the Declaration of Helsinki, the current Good Clinical Practice Guidelines, and the International Conference on Harmonization. Results The relationship between concentration and peak area ratio was found to be linear within the range 24.500–1,836.600 pg/mL for clopidogrel. The correlation coefficient (r) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between test and reference. The point estimates (ratios of geometric mean) were 104.122%, 104.184%, and 109.091% for areas under the plasma concentration–time curve (AUC) AUC0-last, AUC0-∞, and peak plasma concentration Cmax, respectively. These pharmacokinetic parameter values of clopidogrel and its main metabolite lie within the bioequivalence limit (80%–125%) specified by the US Food and Drug Administration and the European Medicines Agency. Conclusion The tested drug product was bioequivalent to the reference drug under fasting conditions and had the same safety profile, which is important to achieve equivalent therapeutic effect with the reference. PMID:25987833
Zaid, Abdel Naser; Al Ramahi, Rowa'; Bustami, Rana; Mousa, Ayman; Khasawneh, Sewar
2015-01-01
The aim of this study was to evaluate the bioequivalence of two drug products, generic clopidogrel bisulfate 75 mg film-coated tablets versus the reference Plavix(®) clopidogrel bisulfate 75 mg film-coated tablets. Bioequivalence of tablets was tested by comparisons against the reference brand product in accordance with the requirements of the Declaration of Helsinki, the current Good Clinical Practice Guidelines, and the International Conference on Harmonization. The relationship between concentration and peak area ratio was found to be linear within the range 24.500-1,836.600 pg/mL for clopidogrel. The correlation coefficient (r) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between test and reference. The point estimates (ratios of geometric mean) were 104.122%, 104.184%, and 109.091% for areas under the plasma concentration-time curve (AUC) AUC0-last, AUC0-∞, and peak plasma concentration C max, respectively. These pharmacokinetic parameter values of clopidogrel and its main metabolite lie within the bioequivalence limit (80%-125%) specified by the US Food and Drug Administration and the European Medicines Agency. The tested drug product was bioequivalent to the reference drug under fasting conditions and had the same safety profile, which is important to achieve equivalent therapeutic effect with the reference.
Duewer, David L; Kline, Margaret C; Romsos, Erica L; Toman, Blaza
2018-05-01
The highly multiplexed polymerase chain reaction (PCR) assays used for forensic human identification perform best when used with an accurately determined quantity of input DNA. To help ensure the reliable performance of these assays, we are developing a certified reference material (CRM) for calibrating human genomic DNA working standards. To enable sharing information over time and place, CRMs must provide accurate and stable values that are metrologically traceable to a common reference. We have shown that droplet digital PCR (ddPCR) limiting dilution end-point measurements of the concentration of DNA copies per volume of sample can be traceably linked to the International System of Units (SI). Unlike values assigned using conventional relationships between ultraviolet absorbance and DNA mass concentration, entity-based ddPCR measurements are expected to be stable over time. However, the forensic community expects DNA quantity to be stated in terms of mass concentration rather than entity concentration. The transformation can be accomplished given SI-traceable values and uncertainties for the number of nucleotide bases per human haploid genome equivalent (HHGE) and the average molar mass of a nucleotide monomer in the DNA polymer. This report presents the considerations required to establish the metrological traceability of ddPCR-based mass concentration estimates of human nuclear DNA. Graphical abstract The roots of metrological traceability for human nuclear DNA mass concentration results. Values for the factors in blue must be established experimentally. Values for the factors in red have been established from authoritative source materials. HHGE stands for "haploid human genome equivalent"; there are two HHGE per diploid human genome.
Evaluation of factors affecting CGMS calibration.
Buckingham, Bruce A; Kollman, Craig; Beck, Roy; Kalajian, Andrea; Fiallo-Scharer, Rosanna; Tansey, Michael J; Fox, Larry A; Wilson, Darrell M; Weinzimer, Stuart A; Ruedy, Katrina J; Tamborlane, William V
2006-06-01
The optimal number/timing of calibrations entered into the CGMS (Medtronic MiniMed, Northridge, CA) continuous glucose monitoring system have not been previously described. Fifty subjects with Type 1 diabetes mellitus (10-18 years old) were hospitalized in a clinical research center for approximately 24 h on two separate days. CGMS and OneTouch Ultra meter (LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13%, and 13% when using three, four, five, and seven calibration values, respectively (P < 0.001). Corresponding percentages of CGMS-reference pairs meeting the International Organisation for Standardisation criteria were 66%, 67%, 71%, and 72% (P < 0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9 p.m. and 6 a.m. (median difference, -2 vs. -9 mg/dL, P < 0.001; median RAD, 12% vs. 15%, P = 0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5 to <1.0, 1.0 to <1.5, and >or=1.5 mg/dL/min, median RAD values were 13% versus 14% versus 17% versus 19%, respectively (P = 0.05). Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy.
Quantification of adulterations in extra virgin flaxseed oil using MIR and PLS.
de Souza, Letícia Maria; de Santana, Felipe Bachion; Gontijo, Lucas Caixeta; Mazivila, Sarmento Júnior; Borges Neto, Waldomiro
2015-09-01
This paper proposes a new method for the quantitative analysis of soybean oil (SO) and sunflower oil (SFO) as adulterants in extra virgin flaxseed oil (EFO) by applying Mid Infrared Spectroscopy (MIR) associated with chemometric technique of Partial Least Squares (PLS). The PLS models were built in accordance with standard method ASTM E1655-05 and these showed good correlation between the reference values and those calculated using the PLS models with low error values, with R = 0.998 for SFO and R = 0.999 for SO in EFO. These models were validated analytically in accordance with Brazilian and international guidelines through the estimate of figures of merit parameters, thus showing an effective and feasible method to control the quality of extra virgin flaxseed oil. Copyright © 2015 Elsevier Ltd. All rights reserved.
Citations of Brazilian physical therapy journals in national publications.
Teixeira, Renan K C; Yamaki, Vitor N; Botelho, Nara M; Teixeira, Renato C
2014-01-01
Quotations in Brazilian journals are mainly obtained from national articles (articles from Brazilian journals); thus, it is essential to determine how frequently these articles reference Brazilian journals. This study sought to verify how frequently national papers are cited in the references of three Brazilian physical therapy journals. All references for articles published in Fisioterapia em Movimento, Fisioterapia e Pesquisa and Revista Brasileira de Fisioterapia between 2010 and 2012 were evaluated. In particular, the numbers of national articles and international articles (articles from international journals) cited in these references were determined. A total of 13,009 references cited by 456 articles were analyzed, and 2,924 (22.47%) of the cited works were national articles. There were no significant differences among the three examined years. A total of 36 (7.89%) articles did not cite national articles, whereas 65 (13.25%) articles cited more national articles than international articles. On average, 22.47% of the works cited by the evaluated articles were national articles. No significant differences were detected among the three analyzed years.
NASA Astrophysics Data System (ADS)
Tan, Le Minh; Thu, Nguyen Ngoc; Ha, Tran Quoc; Nguyen-Luong, Quang
2015-10-01
We present the observation of tweek atmospherics with harmonics m = 1-8 during the solar maximum year, 2013, at Tay Nguyen University, Vietnam (Geog. 12.65° N, 108.02° E). The analysis of 33,690 tweeks on ten international quiet days during 2 months each season, summer (May, August), winter (February, November), and equinox (March, September), shows that tweeks occur about 51 % during summer, 22 % during winter, and 27 % during equinox. The D-region ionosphere is more sharply bounded for harmonics m = 5-6 around an altitude of 85.5 km. The environment of the D-region is more inhomogeneous during winter and equinox seasons. The mean electron density varies from 28.4-225 cm -3, which corresponds to the harmonics m = 1-8 at the mean reflection height of 81.5-87.7 km. The results reveal that the lower reference height in our work as compared to other works is due to the higher level of solar activity. The equivalent electron density profile of the nighttime D-region ionosphere using tweek method during summer, equinox, and winter seasons shows lower values of electron density by 12-58 %, 3-67 %, and 24-76 % than those obtained using the International Reference Ionosphere (IRI-2012) model.
İnal, Tolga; Ataç, Gökçe
2014-01-01
We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas
2017-08-01
Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.
Valdivieso-Mora, Esmeralda; Peet, Casie L.; Garnier-Villarreal, Mauricio; Salazar-Villanea, Monica; Johnson, David K.
2016-01-01
Background: Familismo or familism is a cultural value frequently seen in Hispanic cultures, in which a higher emphasis is placed on the family unit in terms of respect, support, obligation, and reference. Familism has been implicated as a protective factor against mental health problems and may foster the growth and development of children. This study aims at measuring the size of the relationship between familism and mental health outcomes of depression, suicide, substance abuse, internalizing, and externalizing behaviors. Methods: Thirty-nine studies were systematically reviewed to assess the relationship between familism and mental health outcomes. Data from the studies were comprised and organized into five categories: depression, suicide, internalizing symptoms, externalizing symptoms, and substance use. The Cohen's d of each value (dependent variable in comparison to familism) was calculated. Results were weighted based on sample sizes (n) and total effect sizes were then calculated. It was hypothesized that there would be a large effect size in the relationship between familism and depression, suicide, internalizing, and externalizing symptoms and substance use in Hispanics. Results: The meta-analysis showed small effect sizes in the relationship between familism and depression, suicide and internalizing behaviors. And no significant effects for substance abuse and externalizing behaviors. Discussion: The small effects found in this study may be explained by the presence of moderator variables between familism and mental health outcomes (e.g., communication within the family). In addition, variability in the Latino samples and in the measurements used might explain the small and non-significant effects found. PMID:27826269
NASA Astrophysics Data System (ADS)
Kasban, H.; Hamid, Ashraf
2015-12-01
Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.
Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC
NASA Astrophysics Data System (ADS)
Kim, Young-Rok; Park, Eunseo; Oh, Hyungjik Jay; Park, Sang-Young; Lim, Hyung-Chul; Park, Chandeok
2013-12-01
In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/ GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion XP and YP are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.
Vezzosi, T; Mannucci, T; Pistoresi, A; Toma, F; Tognetti, R; Zini, E; Domenech, O; Auriemma, E; Citi, S
2017-05-01
In dogs with chronic valvular heart disease (CVHD), early recognition of pulmonary edema (PE) is of paramount importance. Recent studies in dogs showed that lung ultrasound examination (LUS) is a useful technique to diagnose cardiogenic PE. To describe LUS features in dogs with different stages of CVHD, and to determine its diagnostic accuracy in detecting PE using thoracic radiography as the reference standard. Sixty-three dogs with CVHD. Prospective, multicenter, cross-sectional study. Each dog underwent physical examination, echocardiography, thoracic radiography, and LUS. The LUS findings were classified as absent, rare, numerous, or confluent B-lines. Sensitivity, specificity, and positive and negative predictive values of LUS B-lines to identify PE were calculated using thoracic radiography as the reference standard. Dogs in stage B1 had absent or rare B-lines in 14 of 15 cases (93.3%). Dogs in stage B2 had absent or rare B-lines in 16 of 18 cases (88.9%). All dogs in stage C, without radiographic signs of PE, had absent or rare B-lines. Dogs in stage C, with radiographic signs of PE, had numerous or confluent B-lines in 18 of 20 cases (90%). Lung ultrasound examination detected PE with a sensitivity of 90%, specificity of 93%, and with positive and negative predictive values of 85.7 and 95.2%, respectively. Lung ultrasound examination showed good diagnostic accuracy to identify cardiogenic PE and might be helpful in staging dogs with CVHD. Lung ultrasound examination should be considered as a new, noninvasive diagnostic tool for clinicians managing CVHD in dogs. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Pilot program on patient dosimetry in pediatric interventional cardiology in Chile
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ubeda, Carlos; Vano, Eliseo; Miranda, Patricia
2012-05-15
Purpose: The aim of this study was to present the results of a pilot program on patient dosimetry carried out in Chile during the last 5 yr, using a biplane x-ray angiography system settled for pediatrics. This research was conducted in Latin America under the auspices of the International Atomic Energy Agency (IAEA) supporting programs on radiological protection (RP) of patients. Methods: Patient age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time, and two dosimetric quantities [air kerma-area product (P{sub ka}) and cumulative dose (CD) at the patient entrance reference point] were recorded formore » each procedure. Results: The study includes 544 patients grouped into four age groups. The distributions by age group were 150 for <1 yr; 203 for 1 to <5 yr; 97 for 5 to <10 yr; and 94 for 10 to <16 yr. Median values of P{sub ka} and CD for the four age groups were 0.94, 1.46, 2.13, and 5.03 Gy cm{sup 2} and 23.9, 26.8, 33.5, and 51.6 mGy, respectively. No significant statistical differences were found between diagnostic and therapeutic procedures. A moderate correlation (r = 0.64) was seen between P{sub ka} and patient weight. Conclusions: The dose values reported in this paper were lower than those published in the previous work for the same age groups as a result of the optimization actions carried out by cardiologists and medical physicists with the support of the IAEA. Methodology and results will be used as a starting point for a wider survey in Chile and Latin America with the goal to obtain regional diagnostic reference levels as recently recommended by the International Commission on Radiological Protection for interventional procedures.« less
Bruno, Rosa Maria; Cartoni, Giulia; Stea, Francesco; Armenia, Sabina; Bianchini, Elisabetta; Buralli, Simona; Giannarelli, Chiara; Taddei, Stefano; Ghiadoni, Lorenzo
2017-01-01
Objective The objective of the study is to investigate in the hypertensive population the possible differential association between increased aortic and/or carotid stiffness and organ damage in multiple districts, such as the kidney, the vessels, and the heart. Methods In 314 essential hypertensive patients, carotid–femoral pulse wave velocity (cfPWV, by applanation tonometry) and carotid stiffness (from ultrasound images analysis), together with left ventricular hypertrophy, carotid intima–media thickness, urinary albumin–creatinin ratio, and glomerular filtration rate were measured. Increased cfPWV and carotid stiffness were defined according to either international reference values or the 90th percentile of a local control group (110 age and sex-matched healthy individuals). Results When considering the 90th percentile of a local control group, increased cfPWV was associated with reduced glomerular filtration rate, either when carotid stiffness was increased [odds ratio (OR) 13.27 (confidence limits (CL) 95% 3.86–45.58)] or not [OR 7.39 (CL95% 2.25–24.28)], whereas increased carotid stiffness was associated with left ventricular hypertrophy, either when cfPWV was increased [OR 2.86 (CL95% 1.15–7.09)] or not [OR 2.81 (CL95% 1.13–6.97)]. No association between increased cfPWV or carotid stiffness and target organ damage was found when cutoffs obtained by international reference values were used. The concomitance of both increased cfPWV and carotid stiffness did not have an additive effect on organ damage. Conclusion Aortic and carotid stiffness are differentially associated with target organ damage in hypertensive patients. Regional arterial stiffness as assessed by cfPWV is associated with renal organ damage and local carotid stiffness with cardiac organ damage. PMID:27841779
Gawlik, B M; Martens, D; Henkelmann, B; Schramm, K W; Kettrup, A; Muntau, H
2000-06-01
A sediment reference material (S-37) was prepared as analytical quality control material to be used within an international project on polychlorinated hydrocarbon analysis in two Chinese rivers. The raw material was sampled during a cruise on Yangtse River and transported afterwards to the JRC Ispra for further processing. The material was treated according to the general principles applicable for candidate reference material production. After a thorough homogeneity study of the bulk the material was bottled. A total of 1,080 bottles each containing 50 g of dry sediment powder was obtained. Final homogeneity and stability testing proved the material to be fit for the purpose. Isotope dilution GC/MS was used to establish target values for pentachlorobenzene (1.17 +/- 0.08 ng/g), hexachlorobenzene (3.60 +/- 0.17 ng/g), octachlorostyrene (0.19 +/- 0.01 ng/g), pentachloroanisole (0.52 +/- 0.02 ng/g), alpha-HCH (0.70 +/- 0.05 ng/g), beta-HCH (1.38 +/- 0.18 ng/g), gamma-HCH (0.83 +/- 038 ng/g), 2,4'-DDT (0.36 +/- 0.04 ng/g), 2,4'-DDE (0.29 +/- 0.02 ng/g), 2,4'-DDD (0.49 +/- 0.02), 4,4'-DDT (3.42 +/- 0.47 ng/g), 4,4'-DDD (1.29 +/- 0.17 ng/g), PCB 28 (0.11 +/- 0.01 ng/g), PCB 52 (0.09 +/- 0.003 ng/g), PCB 101 (0.07 +/- 0.003 ng/g), PCB 138 (0.06 +/- 0.003 ng/g) and PCB 153 (0.06 +/- 0.003 ng/g). Furthermore, indicative values for major and minor constituents as well as for polychlorinated dibenzodioxines and -furanes were measured.
Obesity in Youth with Type 1 Diabetes in Germany, Austria, and the United States.
DuBose, Stephanie N; Hermann, Julia M; Tamborlane, William V; Beck, Roy W; Dost, Axel; DiMeglio, Linda A; Schwab, Karl Otfried; Holl, Reinhard W; Hofer, Sabine E; Maahs, David M
2015-09-01
To examine the current extent of the obesity problem in 2 large pediatric clinical registries in the US and Europe and to examine the hypotheses that increased body mass index (BMI) z-scores (BMIz) are associated with greater hemoglobin A1c (HbA1c) and increased frequency of severe hypoglycemia in youth with type 1 diabetes (T1D). International (World Health Organization) and national (Centers for Disease Control and Prevention/German Health Interview and Examination Survey for Children and Adolescents) BMI references were used to calculate BMIz in participants (age 2-<18 years and ≥ 1 year duration of T1D) enrolled in the T1D Exchange (n = 11,435) and the Diabetes Prospective Follow-up (n = 21,501). Associations between BMIz and HbA1c and severe hypoglycemia were assessed. Participants in both registries had median BMI values that were greater than international and their respective national reference values. BMIz was significantly greater in the T1D Exchange vs the Diabetes Prospective Follow-up (P < .001). After stratification by age-group, no differences in BMI between registries existed for children 2-5 years, but differences were confirmed for 6- to 9-, 10- to 13-, and 14- to 17-year age groups (all P < .001). Greater BMIz were significantly related to greater HbA1c levels and more frequent occurrence of severe hypoglycemia across the registries, although these associations may not be clinically relevant. Excessive weight is a common problem in children with T1D in Germany and Austria and, especially, in the US. Our data suggest that obesity contributes to the challenges in achieving optimal glycemic control in children and adolescents with T1D. Copyright © 2015 Elsevier Inc. All rights reserved.
Measurements of indoor 222RN activity in dwellings and workplaces of Curitiba (Brazil)
NASA Astrophysics Data System (ADS)
Corrêa, Janine N.; Paschuk, Sergei A.; Del Claro, Flávia; Kappke, Jaqueline; Perna, Allan F. N.; Schelin, Hugo R.; Denyak, Valeriy
2014-11-01
The present work describes the results of systematic measurements of radon (222Rn) in residential environments and workplaces in the Metropolitan Region of Curitiba (Paraná State, Brazil) during the period 2004-2012. For radon in air activity measurements, polycarbonate Track Etch Detectors CR-39, mounted in diffusion chambers protected by borosilicate glass fiber filters, were used. After being exposed in air, the CR-39 detectors were submitted to a chemical etching in a 6.25 M NaOH solution at 70 °C for 14 h. The alpha particle tracks were identified and manually counted with an optical microscope, and with the results of previously performed calibrations, the indoor activity concentration of 222Rn was calculated. The calibration of CR-39 and the alpha particle tracks chemical development procedures were performed in collaboration the National Institute of Radiological Sciences (NIRS, Japan). The major part of indoor 222Rn concentration in residences was found to be below 100 Bq/m3. In the case of working places, all measurements of 222Rn concentrations were below 100 Bq/m3. These values are considered within the limits set by international regulatory agencies, such as the US EPA and ICRP, which adopt up to 148 and 300 Bq/m3 as upper values for the reference levels for radon gas activity in dwellings, respectively. The latest value of 300 Bq/m3 for radon activity in air is proposed by ICRP considering the upper value for the individual dose reference level for radon exposure of 10 mSv/yr.
Wagner, Franca; Bize, Julie; Racine, Damien; Le Coultre, Regis; Francis, Verdun; Trueb, Philipp; Treier, Reto
2018-05-22
Definition of new national diagnostic reference levels (DRLs) for volume computed tomography dose index (CTDIvol) and dose length product (DLP) for neuro-paediatric CT examinations depending on the medical indication. Methods: Paediatric cranial CT data sets acquired between January 2013 and December 2016 were retrospectively collected between July 2016 and March 2017 from the eight largest university and cantonal hospitals that perform most of the neuro-paediatric CTs in Switzerland. A consensus review of CTDIvol and DLP was undertaken for the three defined anatomical regions: brain, facial bone and petrous bone; each with and without contrast medium application. All indications for cranial CT imaging in paediatrics were assigned to one of these three regions. Descriptive statistical analysis of the distribution of the median values for CTDIvol and DLP yielded minimum, maximum, 25th percentile (1st quartile), median (2nd quartile) and 75th percentile (3rd quartile). New DRLs for neuro-paediatric CT examinations in Switzerland were based on the 75th percentiles of the distributions of the median values of all eight centres. Where appropriate, values were rounded such that the DRLs increase or at least remain constant as the age of the patient increases. Results: Our results revealed DRLs for CTDIvol and DLP up to 20% lower than the DRLs used so far in Switzerland and elsewhere in Europe. Conclusions: This study provides Swiss neuro-paediatric CT DRL values to establish optimum conditions for paediatric cranial CT examinations. Periodic national updates of DRLs, following international comparisons, are essential. . Creative Commons Attribution license.
Snozek, C L H; Katzmann, J A; Kyle, R A; Dispenzieri, A; Larson, D R; Therneau, T M; Melton, L J; Kumar, S; Greipp, P R; Clark, R J; Rajkumar, S V
2008-10-01
To determine if the serum free light chain (FLC) ratio has prognostic value in patients with symptomatic multiple myeloma (MM), baseline serum samples from a well-characterized cohort of 790 newly diagnosed MM patients were tested with the FLC assay. FLC ratio was calculated as kappa/lambda (reference range 0.26-1.65). On the basis of the distribution of values, a cutpoint kappa/lambda FLC ratio of <0.03 or >32 was chosen for further analysis. Overall survival was significantly inferior in patients with an abnormal FLC ratio of <0.03 or >32 (n=479) compared with those with an FLC ratio between 0.03 and 32 (n=311), with median survival of 30 versus 39 months, respectively. We incorporated abnormal FLC ratio with the International Staging System (ISS) risk factors (that is, albumin <3.5 g/dl and serum beta(2)-microglobulin >or=3.5 g/l), to create a risk stratification model with improved prognostic capabilities. Patients with 0, 1, 2 or 3 adverse risk factors had significantly different overall survival, with median survival times of 51, 39, 30 and 22 months, respectively (P<0.001). These findings suggest that the serum FLC ratio at initial diagnosis is an important predictor of prognosis in myeloma, and can be incorporated into the ISS for improved risk stratification.
Burst strength of tubing and casing based on twin shear unified strength theory.
Lin, Yuanhua; Deng, Kuanhai; Sun, Yongxing; Zeng, Dezhi; Liu, Wanying; Kong, Xiangwei; Singh, Ambrish
2014-01-01
The internal pressure strength of tubing and casing often cannot satisfy the design requirements in high pressure, high temperature and high H2S gas wells. Also, the practical safety coefficient of some wells is lower than the design standard according to the current API 5C3 standard, which brings some perplexity to the design. The ISO 10400: 2007 provides the model which can calculate the burst strength of tubing and casing better than API 5C3 standard, but the calculation accuracy is not desirable because about 50 percent predictive values are remarkably higher than real burst values. So, for the sake of improving strength design of tubing and casing, this paper deduces the plastic limit pressure of tubing and casing under internal pressure by applying the twin shear unified strength theory. According to the research of the influence rule of yield-to-tensile strength ratio and mechanical properties on the burst strength of tubing and casing, the more precise calculation model of tubing-casing's burst strength has been established with material hardening and intermediate principal stress. Numerical and experimental comparisons show that the new burst strength model is much closer to the real burst values than that of other models. The research results provide an important reference to optimize the tubing and casing design of deep and ultra-deep wells.
Burst Strength of Tubing and Casing Based on Twin Shear Unified Strength Theory
Lin, Yuanhua; Deng, Kuanhai; Sun, Yongxing; Zeng, Dezhi; Liu, Wanying; Kong, Xiangwei; Singh, Ambrish
2014-01-01
The internal pressure strength of tubing and casing often cannot satisfy the design requirements in high pressure, high temperature and high H2S gas wells. Also, the practical safety coefficient of some wells is lower than the design standard according to the current API 5C3 standard, which brings some perplexity to the design. The ISO 10400: 2007 provides the model which can calculate the burst strength of tubing and casing better than API 5C3 standard, but the calculation accuracy is not desirable because about 50 percent predictive values are remarkably higher than real burst values. So, for the sake of improving strength design of tubing and casing, this paper deduces the plastic limit pressure of tubing and casing under internal pressure by applying the twin shear unified strength theory. According to the research of the influence rule of yield-to-tensile strength ratio and mechanical properties on the burst strength of tubing and casing, the more precise calculation model of tubing-casing's burst strength has been established with material hardening and intermediate principal stress. Numerical and experimental comparisons show that the new burst strength model is much closer to the real burst values than that of other models. The research results provide an important reference to optimize the tubing and casing design of deep and ultra-deep wells. PMID:25397886
NASA Astrophysics Data System (ADS)
Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.
2009-01-01
In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Race for resources: continuing struggles over minerals and fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanzer, M.
1980-01-01
Analyzing the mineral crisis within the historical context of the workings of the international capitalist system is necessary since capitalism spawned the industrial revolution, which in turn led to the vast expansion of mineral use. The analysis begins with the multinational companies that dominate the international mineral industry because they are generally the leading forces in the struggle for control of mineral resources and profits. The focus is twofold: (1) on those minerals that are important as economic inputs and in money value, including the metals copper, bauxite, nickel, and iron ore; and (2) to a lesser extent, on themore » fuels. The emphasis is on the current picture and likely changes in the future. Case studies illustrate some of the major forces at work. Crucial problem areas of the future will include the roles of technology, the Third World, and socialist countries. 26 references, 24 tables.« less
Open innovation as a new paradigm for global collaborations in health.
Dandonoli, Patricia
2013-08-30
Open innovation, which refers to combining internal and external ideas and internal and external paths to market in order to achieve advances in processes or technologies, is an attractive paradigm for structuring collaborations between developed and developing country entities and people. Such open innovation collaborations can be designed to foster true co-creation among partners in rich and poor settings, thereby breaking down hierarchies and creating greater impact and value for each partner. Using an example from Concern Worldwide's Innovations for Maternal, Newborn &Child Health initiative, this commentary describes an early-stage pilot project built around open innovation in a low resource setting, which puts communities at the center of a process involving a wide range of partners and expertise, and considers how it could be adapted and make more impactful and sustainable by extending the collaboration to include developed country partners.
NASA Astrophysics Data System (ADS)
Hao, Huadong; Shi, Haolei; Yi, Pengju; Liu, Ying; Li, Cunjun; Li, Shuguang
2018-01-01
A Volume Metrology method based on Internal Electro-optical Distance-ranging method is established for large vertical energy storage tank. After analyzing the vertical tank volume calculation mathematical model, the key processing algorithms, such as gross error elimination, filtering, streamline, and radius calculation are studied for the point cloud data. The corresponding volume values are automatically calculated in the different liquids by calculating the cross-sectional area along the horizontal direction and integrating from vertical direction. To design the comparison system, a vertical tank which the nominal capacity is 20,000 m3 is selected as the research object, and there are shown that the method has good repeatability and reproducibility. Through using the conventional capacity measurement method as reference, the relative deviation of calculated volume is less than 0.1%, meeting the measurement requirements. And the feasibility and effectiveness are demonstrated.
Li, Meng-Jiao; Ge, Miao; Wang, Cong-Xia; Cen, Min-Yi; Jiang, Ji-Lin; He, Jin-Wei; Lin, Qian-Yi; Liu, Xin
2016-08-20
To analyze the relationship between the reference values of fibrinogen (FIB) in healthy Chinese adults and geographical factors to provide scientific evidences for establishing the uniform standard. The reference values of FIB of 10701 Chinese healthy adults from 103 cities were collected to investigate their relationship with 18 geographical factors including spatial index, terrain index, climate index, and soil index. Geographical factors that significantly correlated with the reference values were selected for constructing the BP neural network model. The spatial distribution map of the reference value of FIB of healthy Chinese adults was fitted by disjunctive kriging interpolation. We used the 5-layer neural network and selected 2000 times of training covering 11 hidden layers to build the simulation rule for simulating the relationship between FIB and geographical environmental factors using the MATLAB software. s The reference value of FIB in healthy Chinese adults was significantly correlated with the latitude, sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual range of air temperature, average annual soil gravel content, and soil cation exchange capacity (silt). The artificial neural networks were created to analyze the simulation of the selected indicators of geographical factors. The spatial distribution map of the reference values of FIB in healthy Chinese adults showed a distribution pattern that FIB levels were higher in the South and lower in the North, and higher in the East and lower in the West. When the geographical factors of a certain area are known, the reference values of FIB in healthy Chinese adults can be obtained by establishing the neural network mode or plotting the spatial distribution map.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ubeda, Carlos, E-mail: cubeda@uta.cl; Miranda, Patricia; Vano, Eliseo
Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-areamore » product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.« less
Ubeda, Carlos; Miranda, Patricia; Vano, Eliseo
2015-02-01
To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm 2 for <1 yr; 1.74 and 1.90 Gy cm 2 for 1 to <5 yr; 2.83 and 3.22 Gy cm 2 for 5 to <10 yr; and 7.34 and 8.68 Gy cm 2 for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm 2 /kg) for diagnostic and therapeutic procedures. The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate. © 2015 American Association of Physicists in Medicine.
Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).
Maas, Miriam; Keet, Dewald F; Nielen, Mirjam
2013-08-01
Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Implementation of standardization in clinical practice: not always an easy task.
Panteghini, Mauro
2012-02-29
As soon as a new reference measurement system is adopted, clinical validation of correctly calibrated commercial methods should take place. Tracing back the calibration of routine assays to a reference system can actually modify the relation of analyte results to existing reference intervals and decision limits and this may invalidate some of the clinical decision-making criteria currently used. To maintain the accumulated clinical experience, the quantitative relationship to the previous calibration system should be established and, if necessary, the clinical decision-making criteria should be adjusted accordingly. The implementation of standardization should take place in a concerted action of laboratorians, manufacturers, external quality assessment scheme organizers and clinicians. Dedicated meetings with manufacturers should be organized to discuss the process of assay recalibration and studies should be performed to obtain convincing evidence that the standardization works, improving result comparability. Another important issue relates to the surveillance of the performance of standardized assays through the organization of appropriate analytical internal and external quality controls. Last but not least, uncertainty of measurement that fits for this purpose must be defined across the entire traceability chain, starting with the available reference materials, extending through the manufacturers and their processes for assignment of calibrator values and ultimately to the final result reported to clinicians by laboratories.
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Han, Xiao; Ge, Miao; Dong, Jie; Xue, Ranying; Wang, Zixuan; He, Jinwei
2014-09-01
The aim of this paper is to analyze the geographical distribution of reference value of aging people's left ventricular end systolic diameter (LVDs), and to provide a scientific basis for clinical examination. The study is focus on the relationship between reference value of left ventricular end systolic diameter of aging people and 14 geographical factors, selecting 2495 samples of left ventricular end systolic diameter (LVDs) of aging people in 71 units of China, in which including 1620 men and 875 women. By using the Moran's I index to make sure the relationship between the reference values and spatial geographical factors, extracting 5 geographical factors which have significant correlation with left ventricular end systolic diameter for building the support vector regression, detecting by the method of paired sample t test to make sure the consistency between predicted and measured values, finally, makes the distribution map through the disjunctive kriging interpolation method and fits the three-dimensional trend of normal reference value. It is found that the correlation between the extracted geographical factors and the reference value of left ventricular end systolic diameter is quite significant, the 5 indexes respectively are latitude, annual mean air temperature, annual mean relative humidity, annual precipitation amount, annual range of air temperature, the predicted values and the observed ones are in good conformity, there is no significant difference at 95% degree of confidence. The overall trend of predicted values increases from west to east, increases first and then decreases from north to south. If geographical values are obtained in one region, the reference value of left ventricular end systolic diameter of aging people in this region can be obtained by using the support vector regression model. It could be more scientific to formulate the different distributions on the basis of synthesizing the physiological and the geographical factors. -Use Moran's index to analyze the spatial correlation. -Choose support vector machine to build model that overcome complexity of variables. -Test normal distribution of predicted data to guarantee the interpolation results. -Through trend analysis to explain the changes of reference value clearly. Copyright © 2014 Elsevier Inc. All rights reserved.
Reference-dependent risk sensitivity as rational inference.
Denrell, Jerker C
2015-07-01
Existing explanations of reference-dependent risk sensitivity attribute it to cognitive imperfections and heuristic choice processes. This article shows that behavior consistent with an S-shaped value function could be an implication of rational inferences about the expected values of alternatives. Theoretically, I demonstrate that even a risk-neutral Bayesian decision maker, who is uncertain about the reliability of observations, should use variability in observed outcomes as a predictor of low expected value for outcomes above a reference level, and as a predictor of high expected value for outcomes below a reference level. Empirically, I show that combining past outcomes using an S-shaped value function leads to accurate predictions about future values. The theory also offers a rationale for why risk sensitivity consistent with an inverse S-shaped value function should occur in experiments on decisions from experience with binary payoff distributions. (c) 2015 APA, all rights reserved).
Waist circumference distribution in Colombian schoolchildren and adolescents: The FUPRECOL Study.
Caicedo-Álvarez, Juan Carlos; Correa-Bautista, Jorge Enrique; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Ramírez-Vélez, Robinson
2016-01-01
This study was intended to establish the percentile distribution of waist circumference in schoolchildren from Bogota, Colombia, participating in the FUPRECOL Study. A cross-sectional study conducted in 3,005 children and 2,916 adolescents aged 9 to 17.9 years. Height, weight, waist circumference, hip circumference, and self-assessed sexual maturity status were recorded. Percentiles (3(rd), 10(th), 25(th), 50(th), 75(th), 90(th), and 97(th)) and smoothed sex- and age-specific curves were calculated, and the waist circumference values found were compared to international references from other ethnic populations. Fifty-seven percent of the overall population (n=5,921) were females (mean age, 12.7±2.3 years). In most age groups, waist circumference was greater in boys as compared to girls. The increase between the 50(th) and 97(th) percentiles by age was 15.7cm in boys aged 9 to 9.9 years and 16.0cm in girls aged 11-11.9 years. Comparison of our study results, by age group and sex, to international references showed that our 50(th) percentile was lower than reported in Peru and the UK except for studies in India, Venezuela (Merida), US, and Spain was higher. Age- and sex-specific percentiles of waist circumference obtained from children and adolescents from Bogota, Colombia, are reported. They may be used as a reference both for nutritional assessment and for predicting cardiovascular risks at early ages. Copyright © 2016 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
Efficiency of personal dosimetry methods in vascular interventional radiology.
Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Giacomini, Guilherme; Maués, Nadine Helena Pelegrino Bastos; Nicolucci, Patrícia; de Freitas, Carlos Clayton Macedo; Alvarez, Matheus; Pina, Diana Rodrigues de
2017-05-01
The aim of the present study was to determine the efficiency of six methods for calculate the effective dose (E) that is received by health professionals during vascular interventional procedures. We evaluated the efficiency of six methods that are currently used to estimate professionals' E, based on national and international recommendations for interventional radiology. Equivalent doses on the head, neck, chest, abdomen, feet, and hands of seven professionals were monitored during 50 vascular interventional radiology procedures. Professionals' E was calculated for each procedure according to six methods that are commonly employed internationally. To determine the best method, a more efficient E calculation method was used to determine the reference value (reference E) for comparison. The highest equivalent dose were found for the hands (0.34±0.93mSv). The two methods that are described by Brazilian regulations overestimated E by approximately 100% and 200%. The more efficient method was the one that is recommended by the United States National Council on Radiological Protection and Measurements (NCRP). The mean and median differences of this method relative to reference E were close to 0%, and its standard deviation was the lowest among the six methods. The present study showed that the most precise method was the one that is recommended by the NCRP, which uses two dosimeters (one over and one under protective aprons). The use of methods that employ at least two dosimeters are more efficient and provide better information regarding estimates of E and doses for shielded and unshielded regions. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Outdoor characterization of radio frequency electromagnetic fields in a Spanish birth cohort
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calvente, I.; Department of Radiology and Physical Medicine, School of Medicine, University of Granada, Av. Madreid s/n, Granada 18071; Fernández, M.F.
There is considerable public concern in many countries about the possible adverse effects of exposure to non-ionizing radiation electromagnetic fields, especially in vulnerable populations such as children. The aim of this study was to characterize environmental exposure profiles within the frequency range 100 kHz–6 GHz in the immediate surrounds of the dwellings of 123 families from the INMA-Granada birth cohort in Southern Spain, using spot measurements. The arithmetic mean root mean-square electric field (E{sub RMS}) and power density (S{sub RMS}) values were, respectively, 195.79 mV/m (42.3% of data were above this mean) and 799.01 µW/m{sup 2} (30% of values weremore » above this mean); median values were 148.80 mV/m and 285.94 µW/m{sup 2}, respectively. Exposure levels below the quantification limit were assigned a value of 0.01 V/m. Incident field strength levels varied widely among different areas or towns/villages, demonstrating spatial variability in the distribution of exposure values related to the surface area population size and also among seasons. Although recorded values were well below International Commission for Non-Ionizing Radiation Protection reference levels, there is a particular need to characterize incident field strength levels in vulnerable populations (e.g., children) because of their chronic and ever-increasing exposure. The effects of incident field strength have not been fully elucidated; however, it may be appropriate to apply the precautionary principle in order to reduce exposure in susceptible groups. - Highlights: • Spot measurements were performed in the immediate surrounds of children's dwellings. • Mean root mean-square electric field and power density values were calculated. • Most recorded values were far below international standard guideline limits. • Data demonstrate spatial variability in the distribution of exposure levels. • While adverse effects are proven, application of the precautionary principle may be appropriate.« less
Understanding and Applying the Concept of Value Creation in Radiology.
Larson, David B; Durand, Daniel J; Siegal, Daniel S
2017-04-01
The concept of value in radiology has been strongly advocated in recent years as a means of advancing patient care and decreasing waste. This article explores the concept of value creation in radiology and offers a framework for how radiology practices can create value according to the needs of their referring clinicians. Value only exists in the eyes of a customer. We propose that the primary purpose of diagnostic radiology is to answer clinical questions using medical imaging to help guide management of patient care. Because they are the direct recipient of this service, we propose that referring clinicians are the direct customers of a radiology practice and patients are indirect customers. Radiology practices create value as they understand and fulfill their referring clinicians' needs. To narrow those needs to actionable categories, we propose a framework consisting of four major dimensions: (1) how quickly the clinical question needs to be answered, (2) the degree of specialization required to answer the question, (3) how often the referring clinician uses imaging, and (4) the breadth of imaging that the referring clinician uses. We further identify three major settings in which referring clinicians utilize radiological services: (1) emergent or urgent care, (2) primary care, and (3) specialty care. Practices best meet these needs as they engage with their referring clinicians, create a shared vision, work together as a cohesive team, structure the organization to meet referring clinicians' needs, build the tools, and continually improve in ways that help referring clinicians care for patients. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Energy Information Administration (DOE), Washington, DC.
This booklet is a compilation of energy data providing a reference to a much broader range of domestic and international energy data. It is designed especially as a quick reference to major facts about energy. The data includes information for 1976 through 1988, except for international energy data, which is for 1977 through 1987. Graphs, charts,…
Validation of psychoanalytic theories: towards a conceptualization of references.
Zachrisson, Anders; Zachrisson, Henrik Daae
2005-10-01
The authors discuss criteria for the validation of psychoanalytic theories and develop a heuristic and normative model of the references needed for this. Their core question in this paper is: can psychoanalytic theories be validated exclusively from within psychoanalytic theory (internal validation), or are references to sources of knowledge other than psychoanalysis also necessary (external validation)? They discuss aspects of the classic truth criteria correspondence and coherence, both from the point of view of contemporary psychoanalysis and of contemporary philosophy of science. The authors present arguments for both external and internal validation. Internal validation has to deal with the problems of subjectivity of observations and circularity of reasoning, external validation with the problem of relevance. They recommend a critical attitude towards psychoanalytic theories, which, by carefully scrutinizing weak points and invalidating observations in the theories, reduces the risk of wishful thinking. The authors conclude by sketching a heuristic model of validation. This model combines correspondence and coherence with internal and external validation into a four-leaf model for references for the process of validating psychoanalytic theories.
Manfredini, A F; Malagoni, A M; Litmanen, H; Zhukovskaja, L; Jeannier, P; Dal Follo, D; Felisatti, M; Besseberg, A; Geistlinger, M; Bayer, P; Carrabre, J E
2011-03-01
Substances and methods used to increase oxygen blood transport and physical performance can be detected in the blood, but the screening of the athletes to be tested remains a critical issue for the International Federations. This project, AR.I.E.T.T.A., aimed to develop a software capable of analysing athletes' hematological and performance profiles to detect abnormal patterns. One-hundred eighty athletes belonging to the International Biathlon Union gave written informed consent to have their hematological data, previously collected according to anti-doping rules, used to develop the AR.I.E.T.T.A. software. Software was developed with the included sections: 1) log-in; 2) data-entry: where data are loaded, stored and grouped; 3) analysis: where data are analysed, validated scores are calculated, and parameters are simultaneously displayed as statistics, tables and graphs, and individual or subpopulation profiles; 4) screening: where an immediate evaluation of the risk score of the present sample and/or the athlete under study is obtained. The sample risk score or AR.I.E.T.T.A. score is calculated by a simple computational system combining different parameters (absolute values and intra-individual variations) considered concurrently. The AR.I.E.T.T.A. score is obtained by the sum of the deviation units derived from each parameter, considering the shift of the present value from the reference values, based on the number of standard deviations. AR.I.E.T.T.A. enables a quick evaluation of blood results assisting surveillance programs and perform timely target testing controls on athletes by the International Federations. Future studies aiming to validate the AR.I.E.T.T.A. score and improve the diagnostic accuracy will improve the system.
Assessment of radio frequency exposures in schools, homes, and public places in Belgium.
Verloock, Leen; Joseph, Wout; Goeminne, Francis; Martens, Luc; Verlaek, Mart; Constandt, Kim
2014-12-01
Characterization of exposure from emerging radio frequency (RF) technologies in areas where children are present is important. Exposure to RF electromagnetic fields (EMF) was assessed in three "sensitive" microenvironments; namely, schools, homes, and public places located in urban environments and compared to exposure in offices. In situ assessment was conducted by performing spatial broadband and accurate narrowband measurements, providing 6-min averaged electric-field strengths. A distinction between internal (transmitters that are located indoors) and external (outdoor sources from broadcasting and telecommunication) sources was made. Ninety-four percent of the broadband measurements were below 1 V m(-1). The average and maximal total electric-field values in schools, homes, and public places were 0.2 and 3.2 V m(-1) (WiFi), 0.1 and 1.1 V m(-1) (telecommunication), and 0.6 and 2.4 V m(-1) (telecommunication), respectively, while for offices, average and maximal exposure were 0.9 and 3.3 V m(-1) (telecommunication), satisfying the ICNIRP reference levels. In the schools considered, the highest maximal and average field values were due to internal signals (WiFi). In the homes, public places, and offices considered, the highest maximal and average field values originated from telecommunication signals. Lowest exposures were obtained in homes. Internal sources contributed on average more indoors (31.2%) than outdoors (2.3%), while the average contributions of external sources (broadcast and telecommunication sources) were higher outdoors (97.7%) than at indoor positions (68.8%). FM, GSM, and UMTS dominate the total downlink exposure in the outdoor measurements. In indoor measurements, FM, GSM, and WiFi dominate the total exposure. The average contribution of the emerging technology LTE was only 0.6%.
Radiation dose management in thoracic CT: an international survey.
Molinari, Francesco; Tack, Denis M; Boiselle, Philip; Ngo, Long; Mueller-Mang, Christina; Litmanovich, Diana; Bankier, Alexander A
2013-01-01
We aimed to examine current practice patterns of international thoracic radiologists regarding radiation dose management in adult thoracic computed tomography (CT) examinations. An electronic questionnaire was sent to 800 members of five thoracic radiology societies in North America, Europe, Asia, and Latin America addressing radiation dose training and education, standard kVp and mAs settings for thoracic CT, dose reduction practices, clinical scenarios, and demographics. Of the 800 radiologists, 146 responded to our survey. Nearly half (66/146, 45% [95% confidence interval, 37%-53%]) had no formal training in dose reduction, with "self-study of the literature" being the most common form of training (54/146, 37% [29%-45%]). One hundred and seventeen (80% [74%-87%]) had automatic exposure control, and 76 (65% [56%-74%]) used it in all patients. Notably, most respondents (89% [84%-94%]) used a 120 to 125 kVp standard setting, whereas none used 140 kVp. The most common average dose-length-product (DLP) value was 150 to 249 mGy.cm (75/146, 51% [43%-59%]), and 59% (51%-67%) delivered less than 250 mGy.cm in a 70 kg patient. There was a tendency towards higher DLP values with multidetector-row CT. Age, gender, and pregnancy were associated more with dose reduction than weight and clinical indication. Efforts for reducing patient radiation dose are highly prevalent among thoracic radiologists. Areas for improvement include reduction of default tube current settings, reduction of anatomical scan coverage, greater use of automatic exposure control, and eventually, reduction of current reference dose values. Our study emphasizes the need for international guidelines to foster greater conformity in dose reduction by thoracic radiologists.
Ekşioğlu, Mahmut
2016-01-01
Normative data are of importance in ergonomics and clinical settings. Applying normative data internationally is questionable. To this end, this study aimed to establish gender- and age-specific reference values for static (isometric) hand grip strength of normal population of Turkey with special regard to occupational demand, and compare them with the international norms. The secondary aims were to investigate the effects of gender, age-group, weight-group, job-group, hand and several anthropometric variables on static grip strength. A sample of 211 (128 male and 83 female) volunteers aged between 18 and 69 with various occupations participated in the study. Grip strength data were collected using a Jamar dynamometer with standard testing position, protocol and instructions. The mean and std deviation of maximum voluntary static grip strength values (in N) for dominant and non-dominant hands respectively were 455.2 ± 73.6 and 441.5 ± 72.6 for males, and 258 ± 46.1 and 246.2 ± 49.1 for females. The mean female strength was about 57% of the mean male strength value for both dominant and non-dominant hands. There was a curvilinear relationship of grip strength to age, significant differences between genders, hands, and some age-groups, and a correlation to height, body-mass, BMI and hand dimensions depending on the gender. The comparisons with the norms of other world populations indicate that there are cross-national grip strength variations among some nations but not all. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
International Geomagnetic Reference Field: the third generation.
Peddie, N.W.
1982-01-01
In August 1981 the International Association of Geomagnetism and Aeronomy revised the International Geomagnetic Reference Field (IGRF). It is the second revision since the inception of the IGRF in 1968. The revision extends the earlier series of IGRF models from 1980 to 1985, introduces a new series of definitive models for 1965-1976, and defines a provisional reference field for 1975- 1980. The revision consists of: 1) a model of the main geomagnetic field at 1980.0, not continuous with the earlier series of IGRF models together with a forecast model of the secular variation of the main field during 1980-1985; 2) definitive models of the main field at 1965.0, 1970.0, and 1975.0, with linear interpolation of the model coefficients specified for intervening dates; and 3) a provisional reference field for 1975-1980, defined as the linear interpolation of the 1975 and 1980 main-field models.-from Author
ERIC Educational Resources Information Center
Wells, John
2011-01-01
This article provides a critical review of the way that the International Baccalaureate (IB) promotes international education and international mindedness through the IB Learner Profile. While discussing theories of values and attitudes, and the teaching of values and theories of value acquisition, the paucity of such topics in IB texts is noted.…
NASA Astrophysics Data System (ADS)
Tampubolon, Togi; Hutahaean, Juniar; Siregar, Suryani N. J.
2018-03-01
Underwater research often uses geomagnets. It is one of the geophysical methods for measuring magnetic field variations. This research was done to identify how the subsurface rock structure is and determine kinds of rock based on its susceptibility value in Siogung-ogung geothermal area, Pangururan, Samosir District. The tool measurement of total magnetic field called Proton Precission Magnetometer, positioning using Global Position System, and north axis determination using geological compass. Data collection was done randomly with total 51 measuring points obtained. Data analysis started with International geomagnetics Reference Field correction to obtain the total magnetic field anomaly. Then, the data analysis of total magnetic anomaly was done by using surfer program 12. To get a magnetic anomaly cross section used Magdc For Windows program. Magnetic measurement results indicated that the variation of magnetic field strength in each point with the lowest magnetic intensity value of 41785.67 nano tesla. The highest magnetic intensity value is 43140, 33. From the results of qualitative interpretation, the magnetic anomaly value is at -200.92 to 1154.45 whereas the quantitative interpretive results of model show the existence of degradation and andesitic rocks, with the value of susceptibility
[Diagnostic kits in parasitology: which controls?].
Rossi, P
2004-06-01
The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.
Pilot study on peptide purity—synthetic human C-peptide
NASA Astrophysics Data System (ADS)
Josephs, R. D.; Li, M.; Song, D.; Daireaux, A.; Choteau, T.; Stoppacher, N.; Westwood, S.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Melanson, J. E.; Ün, I.; Gören, A. C.; Quaglia, M.; Warren, J.
2017-01-01
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P55.2, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Four Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-P55.2. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a quantitative nuclear magnetic resonance spectroscopy (qNMR) corrected for peptide impurities. Other participants provided results obtained by peptide impurity corrected amino acid analysis (PICAA) or elemental analysis (PICCHN). It was decided to assign reference values based on the KCRVs of CCQM-K115 for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most exhaustive and elaborate set of results is taken for the calculation of the reference value. The reference value for the peptide related impurity mass fractions of the material was 83.3 mg/g with a combined standard uncertainty of 1.5 mg/g. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in many cases only a very small number of impurities have been identified and quantified resulting in an underestimation of the peptide related impurity mass fractions. The reference value for the mass fraction of hCP for CCQM-KP55.2 is 801.8 mg/g with a corresponding combined standard uncertainty of 3.1 mg/g. Inspection of the degree of equivalence plots for CCQM-P55.2 for the mass fraction of hCP shows that three results agree with the reference value. Main text To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.
André, A L; Padez, C; Rosado-Marques, V; Griffiths, P L; Varela-Silva, M I
2017-11-01
Portugal has one of the highest rates of childhood overweight and obesity in Europe. However, little is known about the health of ethnic minorities living in its capital city, Lisbon. The Cape Verdean community in Lisbon tend to have low educational levels, material deprivation and struggle with discrimination and racism, factors that would probably be associated with a higher prevalence of overweight and obesity. Data for the Cape Verdean population were collected in three different time periods by three different research teams in 1993, 2009 and 2013 and included children aged 6-12 years living in the Cova da Moura neighbourhood of the Greater Lisbon Metro Area. The Portuguese national survey was conducted between 2009 and 2010 at public and private schools in mainland Portugal and included height, weight, skinfolds and arm and waist circumferences. From these survey data body mass index (BMI) and prevalence of stunting (chronic malnutrition - low height-for-age) and underweight (low weight-for-age) were calculated according to reference values proposed by Frisancho (2008). Overweight and obesity prevalence values were defined based on the references established by the International Obesity Task Force. The results show significant differences in height between Cape Verdean and Portuguese boys and girls. Generally, Cape Verdeans' growth falls within the healthy range of international growth references across all of the survey data collected. Cape Verdean rates for combined overnutrition (overweight and obesity) in 2013 (9.8% for boys and 16.7% for girls) were lower than those of the Portuguese (33% for boys and 31.7% for girls). Logistic regression models showed that Cape Verdean children had a lower risk of being overweight or obese when accounting for breast-feeding, birth weight, maternal education and occupation. Despite living in a deprived neighbourhood these Cape Verdean children seemed to have grown more healthily than Portuguese ancestry children. The challenge for policymakers will be to support improvement of the poverty-related living conditions of this community without creating a risky environment for increasing prevalence of overweight and obesity.
Contribution of Starlette, Stella, and AJISAI to the SLR-derived global reference frame
NASA Astrophysics Data System (ADS)
Sośnica, Krzysztof; Jäggi, Adrian; Thaller, Daniela; Beutler, Gerhard; Dach, Rolf
2014-08-01
The contribution of Starlette, Stella, and AJISAI is currently neglected when defining the International Terrestrial Reference Frame, despite a long time series of precise SLR observations and a huge amount of available data. The inferior accuracy of the orbits of low orbiting geodetic satellites is the main reason for this neglect. The Analysis Centers of the International Laser Ranging Service (ILRS ACs) do, however, consider including low orbiting geodetic satellites for deriving the standard ILRS products based on LAGEOS and Etalon satellites, instead of the sparsely observed, and thus, virtually negligible Etalons. We process ten years of SLR observations to Starlette, Stella, AJISAI, and LAGEOS and we assess the impact of these Low Earth Orbiting (LEO) SLR satellites on the SLR-derived parameters. We study different orbit parameterizations, in particular different arc lengths and the impact of pseudo-stochastic pulses and dynamical orbit parameters on the quality of the solutions. We found that the repeatability of the East and North components of station coordinates, the quality of polar coordinates, and the scale estimates of the reference are improved when combining LAGEOS with low orbiting SLR satellites. In the multi-SLR solutions, the scale and the component of geocenter coordinates are less affected by deficiencies in solar radiation pressure modeling than in the LAGEOS-1/2 solutions, due to substantially reduced correlations between the geocenter coordinate and empirical orbit parameters. Eventually, we found that the standard values of Center-of-mass corrections (CoM) for geodetic LEO satellites are not valid for the currently operating SLR systems. The variations of station-dependent differential range biases reach 52 and 25 mm for AJISAI and Starlette/Stella, respectively, which is why estimating station-dependent range biases or using station-dependent CoM, instead of one value for all SLR stations, is strongly recommended. This clearly indicates that the ILRS effort to produce CoM corrections for each satellite, which are site-specific and depend on the system characteristics at the time of tracking, is very important and needs to be implemented in the SLR data analysis.
NASA Astrophysics Data System (ADS)
Sarif; Kurauchi, Shinya; Yoshii, Toshio
2017-06-01
In the conventional travel behavior models such as logit and probit, decision makers are assumed to conduct the absolute evaluations on the attributes of the choice alternatives. On the other hand, many researchers in cognitive psychology and marketing science have been suggesting that the perceptions of attributes are characterized by the benchmark called “reference points” and the relative evaluations based on them are often employed in various choice situations. Therefore, this study developed a travel behavior model based on the mental accounting theory in which the internal reference points are explicitly considered. A questionnaire survey about the shopping trip to the CBD in Matsuyama city was conducted, and then the roles of reference points in travel mode choice contexts were investigated. The result showed that the goodness-of-fit of the developed model was higher than that of the conventional model, indicating that the internal reference points might play the major roles in the choice of travel mode. Also shown was that the respondents seem to utilize various reference points: some tend to adopt the lowest fuel price they have experienced, others employ fare price they feel in perceptions of the travel cost.
Hip strength and range of motion: Normal values from a professional football league.
Mosler, Andrea B; Crossley, Kay M; Thorborg, Kristian; Whiteley, Rod J; Weir, Adam; Serner, Andreas; Hölmich, Per
2017-04-01
To determine the normal profiles for hip strength and range of motion (ROM) in a professional football league in Qatar, and examine the effect of leg dominance, age, past history of injury, and ethnicity on these profiles. Cross-sectional cohort study. Participants included 394 asymptomatic, male professional football players, aged 18-40 years. Strength was measured using a hand held dynamometer with an eccentric test in side-lying for hip adduction and abduction, and the squeeze test in supine with 45° hip flexion. Range of motion measures included: hip internal and external rotation in 90° flexion, hip IR in prone, bent knee fall out and hip abduction in side-lying. Demographic information was collected and the effect on the profiles was analysed using linear mixed models with repeated measures. Strength values (mean±SD) were: adduction=3.0±0.6Nm/kg, abduction=2.6±0.4Nm/kg, adduction/abduction ratio=1.2±0.2, Squeeze test=3.6±0.8N/kg. Range of motion values: internal rotation in flexion=32±8°, external rotation=38±8°, internal rotation in prone=38±8°, bent knee fall out=13±4.4cm, abduction in side-lying=50±7.3°. Leg dominance had no clinically relevant effect on these profiles. Multivariate analysis demonstrated that age had a minor influence on squeeze strength (-0.03N/kg/year), external rotation (-0.30°/year) and abduction range (-0.19°/year) but past history of injury, and ethnicity did not. Normal values are documented for hip strength and range of motion that can be used as reference profiles in the clinical assessment, screening, and management of professional football players. Leg dominance, recent past injury history and ethnicity do not need to be accounted for when using these profiles for comparison purposes. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.