Compact near-IR and mid-IR cavity ring down spectroscopy device
NASA Technical Reports Server (NTRS)
Miller, J. Houston (Inventor)
2011-01-01
This invention relates to a compact cavity ring down spectrometer for detection and measurement of trace species in a sample gas using a tunable solid-state continuous-wave mid-infrared PPLN OPO laser or a tunable low-power solid-state continuous wave near-infrared diode laser with an algorithm for reducing the periodic noise in the voltage decay signal which subjects the data to cluster analysis or by averaging of the interquartile range of the data.
Laohavaleeson, Somvadee; Barriere, Steven L; Nicolau, David P; Kuti, Joseph L
2008-12-01
To determine the cost-effectiveness of telavancin versus vancomycin for the treatment of complicated skin and skin structure infections (cSSSIs). Pharmacoeconomic analysis conducted from the hospital's perspective using data from the Assessment of Telavancin in Complicated Skin and Skin Structure Infections (ATLAS) phase III clinical trial. One hundred twenty-nine hospitals in the United States and internationally. A total of 1044 clinically evaluable patients who were hospitalized with a cSSSI during the ATLAS trial and who received at least one dose of telavancin or vancomycin in the hospital. Diagnosis-related group-specific hospital bed costs, antibiotic acquisition prices, and cost of vancomycin monitoring were applied to the resource utilization data collected during the ATLAS trial. Infection-related length of stay (LOS(ir)) and hospitalization costs (COST(ir)) were compared between the telavancin (514 patients) and vancomycin (530 patients) groups. Incremental cost-effectiveness ratios (ICERs) were calculated for the total population and a subset of patients infected with methicillin-resistant Staphylococcus aureus (MRSA) by using a 25,000-sample bootstrap analysis. During sensitivity analyses, the daily acquisition price for telavancin was increased from the equivalent to vancomycin ($13.44) to $50, $100, $150, or $200, and the rate of MRSA acquisition was varied between 30% and 75%. The median (interquartile range) LOS(ir) was 8 days (6-12 days) for both telavancin and vancomycin (p=0.742), and median (interquartile range) COST(ir) was $8118 ($6291-11,758) and $8185 ($6474-11,405), respectively (p=0.560). Similar findings were observed for the MRSA subset. Telavancin cost-effectiveness was greater for the MRSA population versus the total population. During bootstrap analyses of the MRSA population, the ICER for telavancin ranged from dominant (-$9560) to $27,889 as acquisition price was increased. Telavancin LOS(ir) and total COST(ir) were similar to those of vancomycin for the treatment of cSSSIs. Particularly in those infected with MRSA, telavancin may be more cost-effective than vancomycin over the range of acquisition prices tested.
Aso, Yoshimasa; Terasawa, Tomoko; Kato, Kanako; Jojima, Teruo; Suzuki, Kunihiro; Iijima, Toshie; Kawagoe, Yoshiaki; Mikami, Shigeru; Kubota, Yoshiro; Inukai, Toshihiko; Kasai, Kikuo
2013-11-01
A soluble form of CD26/dipeptidyl peptidase 4 (sCD26/DPP4) is found in serum and it has DPP4 enzymatic activity. We investigated whether the serum level of sCD26/DPP4 was influenced by the oral glucose tolerance test (OGTT) in healthy subjects. The serum sCD26/DPP4 level increased significantly from 824.5 ng/mL (interquartile range, from 699.0 to 1050 ng/mL) at baseline to a peak of 985.0 ng/mL (interquartile range, from 796.5 to 1215 ng/mL) during the OGTT (P < 0.0001). The peak sCD26/DPP4 level correlated positively with the baseline age and body mass index, and fasting plasma glucose (FPG), homeostasis model assessment of insulin resistance (HOMA-IR), triglycerides (TG), alanine aminotransferase, and γ-glutamyl transpeptidase (GGT) levels whereas it correlated negatively with high-density lipoprotein (HDL) cholesterol and the serum levels of total and high-molecular weight (HMW) adiponectin. Stepwise regression analysis was done with forward selection of variables, including age, FPG, HOMA-IR, TG, HDL cholesterol, uric acid, GGT, C-reactive protein, and HMW adiponectin. In a model that explained 57.5% of the variation of the peak sCD26/DPP4 level, GGT (β = 0.382, P = 0.007) and HOMA-IR (β = 0.307, P = 0.034) were independent determinants of the peak serum level of sCD26/DPP4. Serum HMW adiponectin decreased significantly from 4.43 μg/mL (interquartile range, from 2.80 to 6.65 μg/mL) at baseline to 4.17 μg/mL (interquartile range, from 2.48 to 6.96 μg/mL) 120 minutes after the oral glucose load (P < 0.0001). The baseline serum level of sCD26/DPP4 showed a significant negative correlation with the percent change of HMW adiponectin during the OGTT. In conclusion, the serum level of sCD26/DPP4 increased acutely after an oral glucose load in apparently healthy subjects. The abrupt increase of serum sCD26/DPP4 after a glucose load may be a marker of insulin resistance that could come from liver or muscle. Copyright © 2013 Mosby, Inc. All rights reserved.
Finnbjornsdottir, Ragnhildur Gudrun; Oudin, Anna; Elvarsson, Bjarki Thor; Gislason, Thorarinn; Rafnsson, Vilhjalmur
2015-04-08
To study the association between daily mortality and short-term increases in air pollutants, both traffic-related and the geothermal source-specific hydrogen sulfide (H₂S). Population-based, time stratified case-crossover. A lag time to 4 days was considered. Seasonal, gender and age stratification were calculated. Also, the best-fit lag when introducing H₂S >7 µg/m(3) was selected by the Akaike Information Criterion (AIC). The population of the greater Reykjavik area (n=181,558) during 2003-2009. Cases were defined as individuals living in the Reykjavik capital area, 18 years or older (N=138,657), who died due to all natural causes (ICD-10 codes A00-R99) other than injury, poisoning and certain other consequences of external causes, or cardiovascular disease (ICD-10 codes I00-I99) during the study period. Percentage increases in risk of death (IR%) following an interquartile range increase in pollutants. The total number of deaths due to all natural causes was 7679 and due to cardiovascular diseases was 3033. The interquartile range increased concentrations of H₂S (2.6 µg/m(3)) were associated with daily all natural cause mortality in the Reykjavik capital area. The IR% was statistically significant during the summer season (lag 1: IR%=5.05, 95% CI 0.61 to 9.68; lag 2: IR%=5.09, 95% CI 0.44 to 9.97), among males (lag 0: IR%=2.26, 95% CI 0.23 to 4.44), and among the elderly (lag 0: IR%=1.94, 95% CI 0.12 to 1.04; lag 1: IR%=1.99, 95% CI 0.21 to 1.04), when adjusted for traffic-related pollutants and meteorological variables. The traffic-related pollutants were generally not associated with statistical significant IR%s. The results suggest that ambient H₂S air pollution may increase mortality in Reykjavik, Iceland. To the best of our knowledge, ambient H₂S exposure has not previously been associated with increased mortality in population-based studies and therefore the results should be interpreted with caution. Further studies are warranted to confirm or refute whether H₂S exposure induces premature deaths. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Owen, S G; Friesen, W T; Roberts, M S; Francis, H; Flux, W
1986-01-01
A community based study of rheumatoid arthritis was undertaken to determine patient characteristics and the patterns of treatment. Three hundred and eighty subjects were visited in their homes throughout Tasmania (pop. 430 000) by a research team. The median age of the sample was 60 years (interquartile range (IR) 49-69), with a female predominance of 2.65 to 1. The average onset age was 41 years (IR 30-53). Prescribing data indicated that polypharmacy was not common in the community, and that the use of slow acting antirheumatic drugs (SAARDs) and oral corticosteroids was not widespread. At the time of the study 26% of subjects were assayed fully functional--class I of the American Rheumatism Association's (ARA) functional classifications. The functional capacity data provided evidence that the spectrum of rheumatoid arthritis found in the community differed from that found in specialist rheumatology clinics. PMID:2939806
Aortoiliac morphologic correlations in aneurysms undergoing endovascular repair.
Ouriel, Kenneth; Tanquilut, Eugene; Greenberg, Roy K; Walker, Esteban
2003-08-01
The feasibility of endovascular aneurysm repair depends on morphologic characteristics of the aortoiliac segment. Knowledge of such characteristics is relevant to safe deployment of a particular device in a single patient and to development of new devices for use in patients with a broader spectrum of anatomic variations. We evaluated findings on computed tomography scans for 277 patients being considered for endovascular aneurysm repair. Aortic neck length and angulation estimates were generated with three-dimensional trigonometry. Specific centerline points were recorded, corresponding to the aorta at the celiac axis, lowest renal artery, cranial aspect of the aneurysm sac, aortic terminus, right hypogastric artery origin, and left hypogastric origin. Aortic neck thrombus and calcium content were recorded, and neck conicity was calculated in degrees. Statistical analysis was performed with the Spearman rank correlation. Data are expressed as median and interquartile range. Median diameter of the aneurysms was 52 mm (interquartile range, 48-59 mm) in minor axis and 56 mm (interquartile range, 51-64 mm) in major axis, and median length was 88 mm (interquartile range, 74-103 mm). Median proximal aortic neck diameter was 26 mm (interquartile range, 22-29 mm), and median neck length was 30 mm (interquartile range, 18-45 mm). The common iliac arteries were similar in diameter (right artery, 16 mm [interquartile range, 13-20 mm]; left artery, 15 mm [interquartile range, 11-18 mm]) and length (right, 59 mm [interquartile range, 50-69 mm]; left, 60 mm [interquartile range, 49-70 mm]). Median angulation of the infrarenal aortic neck was 40 degrees (interquartile range, 29-51 degrees), and median angulation of the suprarenal segment was 45 degrees (interquartile range, 36-57 degrees). By gender, sac diameter, proximal neck diameter, and iliac artery diameter were significantly larger in men. Significant linear associations were identified between sac diameter and sac length, neck angulation, and iliac artery diameter. As the length of the aneurysm sac increased the proximal aortic neck length decreased. Conversely, as the sac length decreased sac eccentricity increased. Mural thrombus content within the neck increased with increasing neck diameter. There is considerable variability in aortoiliac morphologic parameters. Significant associations were found between various morphologic variables, links that are presumably related to a shared pathogenesis for aberration in aortoiliac diameter, length, and angulation. Ultimately this information can be used to develop new endovascular devices with broader applicability and improved long-term results.
Bernardo, Ana Paula; Oliveira, Jose C; Santos, Olivia; Carvalho, Maria J; Cabrita, Antonio; Rodrigues, Anabela
2015-12-07
Insulin resistance has been associated with cardiovascular disease in peritoneal dialysis patients. Few studies have addressed the impact of fast transport status or dialysis prescription on insulin resistance. The aim of this study was to test whether insulin resistance is associated with obesity parameters, peritoneal transport rate, and glucose absorption. Insulin resistance was evaluated with homeostasis model assessment method (HOMA-IR), additionally corrected by adiponectin (HOMA-AD). Enrolled patients were prevalent nondiabetics attending at Santo António Hospital Peritoneal Dialysis Unit, who were free of hospitalization or infectious events in the previous 3 months (51 patients aged 50.4 ± 15.9 years, 59% women). Leptin, adiponectin, insulin-like growth factor-binding protein 1 (IGFBP-1), and daily glucose absorption were also measured. Lean tissue index, fat tissue index (FTI), and relative fat mass (rel.FM) were assessed using multifrequency bioimpedance. Patients were categorized according to dialysate to plasma creatinine ratio at 4 hours, 3.86% peritoneal equilibration test, and obesity parameters. Obesity was present in 49% of patients according to rel.FM. HOMA-IR correlated better with FTI than with body mass index. Significant correlations were found in obese, but not in nonobese patients, between HOMA-IR and leptin, leptin/adiponectin ratio (LAR), and IGFBP-1. HOMA-IR correlated with HOMA-AD, but did not correlate with glucose absorption or transport rate. There were no significant differences in insulin resistance indices, glucose absorption, and body composition parameters between fast and nonfast transporters. A total of 18 patients (35.3%) who had insulin resistance presented with higher LAR and rel.FM (7.3 [12.3, interquartile range] versus 0.7 [1.4, interquartile range], P<0.001, and 39.4 ± 10.1% versus 27.2 ± 11.5%, P=0.002, respectively), lower IGFBP-1 (8.2 ± 7.2 versus 21.0 ± 16.3 ng/ml, P=0.002), but similar glucose absorption and small-solute transport compared with patients without insulin resistance. FTI and LAR were independent correlates of HOMA-IR in multivariate analysis adjusted for glucose absorption and small-solute transport (r=0.82, P<0.001). Insulin resistance in nondiabetic peritoneal dialysis patients is associated with obesity and LAR independent of glucose absorption and small-solute transport status. Fast transport status was not associated with higher likelihood of obesity or insulin resistance. Copyright © 2015 by the American Society of Nephrology.
Vogeser, Michael; König, Daniel; Frey, Ingrid; Predel, Hans-Georg; Parhofer, Klaus Georg; Berg, Aloys
2007-09-01
Lifestyle changes with increased physical activity and balanced energy intake are recognized as the principal interventions in obesity and insulin resistance. Only few prospective studies, however, have so far addressed the potential role of routine biochemical markers of insulin sensitivity in the monitoring of respective interventions. Fasting insulin and glucose was measured in 33 obese individuals undergoing a lifestyle modification program (MOBILIS) at baseline and after 1 year. The HOMA-IR index (homeostasis model of insulin resistance) was calculated as [fasting serum glucose*fasting serum insulin/22.5], with lower values indicating a higher degree of insulin sensitivity. While the median body mass index (BMI) and waist circumference decreased by 10% and 11%, respectively, the HOMA-IR index decreased in an over-proportional manner by 45% within 1 year (BMI baseline, median 35.7, interquartile range (IQR) 33.7-37.7; after 1 year, median 32.2, IQR 29.6-35.1. HOMA-IR baseline, median 2.9, IQR 1.5-4.6; after 1 year 1.6, IQR 0.9-2.7). In contrast to HOMA-IR and fasting serum insulin, no significant changes in fasting serum glucose were observed. Baseline and post-intervention HOMA-IR showed a high degree of inter-individual variation with eight individuals maintaining high HOMA-IR values despite weight loss after 1 year of intervention. Individual changes in the carbohydrate metabolism achieved by a lifestyle intervention program were displayed by fasting serum insulin concentrations and the HOMA-IR but not by fasting glucose measurement alone. Therefore, assessment of the HOMA-IR may help to individualize lifestyle interventions in obesity and to objectify improvements in insulin sensitivity after therapeutic lifestyle changes.
Palliative shunt surgery for patients with leptomeningeal metastasis.
Murakami, Yuta; Ichikawa, Masahiro; Bakhit, Mudathir; Jinguji, Shinya; Sato, Taku; Fujii, Masazumi; Sakuma, Jun; Saito, Kiyoshi
2018-05-01
Leptomeningeal metastasis (LM) is associated with poor prognosis and affects the quality of life (QOL) of end-stage cancer patients. Severe headache associated with hydrocephalus causes reduced QOL. We investigated the clinical value of surgical treatment for hydrocephalus in LM patients. The medical records of 11 consecutive patients who underwent lumboperitoneal shunt (LPS) or ventriculoperitoneal shunt (VPS) at our institution between 2007 and 2016 were investigated. Primary brain tumor patients were excluded. We assessed the neurological status and therapeutic effects at 1 month after the shunt surgery. The patients were three males and eight females with a median age of 58 years (interquartile range [IR] 52-68 years). The median preoperative neutrophil-to-lymphocyte ratio was 6.4 (IR 4.8-9.2). Symptom improvement was observed in nine patients, and severe headache was relieved in seven (88%) out of eight patients. The median Karnofsky performance status scale increased from 40 to 60, and the median overall survival after primary malignancy diagnosis was 27.4 months (IR 19.6-63.1 months). The median survival after the diagnosis of brain parenchymal metastasis, LM, and shunt surgery were 7.2 months (IR 5.1-14.1 months), 3.9 months (IR 3.5-6.3 months), and 3.3 months (IR 2.9-5.7 months), respectively. Shunt surgery for hydrocephalus could offer an effective palliative surgical option for symptom relief especially relief of severe headache, contributing improvement of QOL in LM patients. Copyright © 2018 Elsevier B.V. All rights reserved.
Li, Siou; Yin, Changhao; Zhao, Weina; Zhu, Haifu; Xu, Dan; Xu, Qing; Jiao, Yang; Wang, Xue; Qiao, Hong
2018-01-01
Whether insulin resistance (IR) predicts worse functional outcome in ischemic stroke is still a matter of debate. The aim of the present study is to determine the association between IR and risk of poor outcome in 173 Chinese nondiabetic patients with acute ischemic stroke. This is a prospective, population-based cohort study. Insulin sensitivity, expressed by the homeostasis model assessment (HOMA) of insulin sensitivity (HOMA index = (fasting insulin × fasting glucose)/22.5). IR was defined by HOMA-IR index in the top quartile (Q4). Functional impairment was evaluated at discharge using the modified Rankin scale (mRS). The median (interquartile range) HOMA-IR was 2.14 (1.17–2.83), and Q4 was at least 2.83. There was a significantly positive correlation between HOMA-IR and National Institutes of Health Stroke Scale (r = 0.408; P<0.001). In multivariate analyses, patients in IR group were associated with a higher risk of poor functional outcome (odds ratio (OR) = 3.23; 95% confidence interval (CI) = 1.75–5.08; P=0.001). In multivariate models comparing the third and fourth quartiles against the first quartile of the HOMA-IR, levels of HOMA-IR were associated with poor outcome, and the adjusted risk of poor outcome increased by 207% (OR = 3.05 (95% CI 1.70–4.89), P=0.006) and 429% (5.29 (3.05–9.80), P<0.001). In a receiver operating characteristic curve (ROC) analysis of poor outcome, the area under the curve (AUC) increased from 0.80 to 0.84 (95% CI: 0.79–0.88) by adding HOMA-IR to clinical examination variables (P=0.02). High HOMA-IR index is associated with a poor functional outcome in nondiabetic patients with acute ischemic stroke. PMID:29588341
Tak, Igor; Glasgow, Philip; Langhout, Rob; Weir, Adam; Kerkhoffs, Gino; Agricola, Rintje
2016-03-01
Soccer (football) players often have hip and groin symptoms (HGS), and a previous groin injury is a risk factor for a relapse. Decreased hip range of motion (HROM) has been related to both hip and groin pain and the presence of a cam deformity. How these factors interact is unknown. The first aim was to study whether HGS are associated with HROM. The second aim was to study the association of the presence of a cam deformity with HROM. Additionally, the influence of a cam deformity on the relationship between HGS and HROM was examined. Cross-sectional study; Level of evidence, 3. Seasonal screening data of 2 professional soccer clubs were used. Variables for HGS were current hip or groin pain, the Copenhagen Hip and Groin Outcome Score (HAGOS), and previous hip- and groin-related time-loss injuries (HGTIs). HROM was determined for hip internal rotation (IR), external rotation, and total rotation (TR) in the supine position and for the bent knee fall out (BKFO) test. A cam deformity was defined by an alpha angle >60° on standardized anteroposterior pelvic and frog-leg lateral radiographs. Sixty players (mean [±SD] age, 23.1 ± 4.2 years) were included. All were noninjured at the time of screening. Current hip or groin pain was not associated with HROM. Hips of players in the lowest HAGOS interquartile range (thus most affected by complaints; n = 12) showed less IR (23.9° ± 8.7° vs 28.9° ± 7.8°, respectively; P = .036) and TR (58.2° ± 13.5° vs 65.6° ± 11.8°, respectively; P = .047) than those in the highest interquartile range (n = 29). No such differences were found for BKFO (P = .417). Hips of players with a previous HGTI showed less IR (21.1° ± 6.8° vs 28.3° ± 8.9°, respectively; P < .001) and TR (56.0° ± 8.2° vs 64.5° ± 13.6°, respectively; P < .001) than those without a previous HGTI. This was independent of the presence of a cam deformity. BKFO did not differ between groups (P = .983). Hips with a cam deformity showed less but nonsignificant IR (25.5° ± 10.3° vs 29.0° ± 7.1°, respectively; P = .066) and TR (P = .062) and higher but nonsignificant BKFO values (17.1 cm ± 3.4 cm vs 14.2 cm ± 4.6 cm, respectively; P = .078) than those without a cam deformity. Decreased HROM in professional soccer players is associated with more hip- and groin-related symptoms and with previous injuries, independent of the presence of a cam deformity. © 2015 The Author(s).
Comparison of postural ergonomics between laparoscopic and robotic sacrocolpopexy: a pilot study.
Tarr, Megan E; Brancato, Sam J; Cunkelman, Jacqueline A; Polcari, Anthony; Nutter, Benjamin; Kenton, Kimberly
2015-02-01
To compare resident, fellow, and attending urologic and gynecologic surgeons' musculoskeletal and mental strain during laparoscopic and robotic sacrocolpopexy. Prospective cohort study (Canadian Task Force classification II-2). Academic medical center. Patients who underwent robotic or laparoscopic sacrocolpopexy from October 2009 to January 2011. The Body Part Discomfort (BPD) survey was completed before cases, and the National Aeronautics and Space Administration Task Load Index and BPD survey were completed after cases. Higher scores on BPD and the National Aeronautics and Space Administration Task Load Index indicate greater musculoskeletal discomfort and mental strain. BPD scores were averaged over the following body regions: head/neck, back, hand/wrist, arms, and knees/ankles/feet. Changes in body region-specific discomfort scores were the primary outcomes. Multivariable analysis was performed using mixed-effects linear regression with surgeon as a random effect. Sixteen surgeons participated (53% fellows, 34% residents, and 13% attendings). Thirty-three robotic and 53 laparoscopic cases were analyzed, with a median surgical time of 231 minutes (interquartile range, 204-293 minutes) versus 227 minutes (interquartile range, 203-272 minutes; p = .31), a median estimated blood loss of 100 mL (interquartile range, 50-175 mL) versus 150 mL (interquartile range, 50-200 mL; p = .22), and a mean patient body mass index of 27 ± 4 versus 26 ± 4 kg/m(2) (p = .26), respectively. Robotic surgeries were associated with lower neck/shoulder (-0.19 [interquartile range, -0.32 to -0.01], T = -2.49) and back discomfort scores (-0.35 [interquartile range, -0.58 to 0], T = -2.38) than laparoscopic surgeries. Knee/ankle/foot and arm discomfort increased with case length (0.18 [interquartile range, 0.02-0.3], T = 2.81) and (0.07 [interquartile range, 0.01-0.14], p = .03), respectively. Surgeons performing minimally invasive sacrocolpopexy experienced less neck, shoulder, and back discomfort when surgery was performed robotically. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Hemoglobin Levels Across the Pediatric Critical Care Spectrum: A Point Prevalence Study.
Hassan, Nabil E; Reischman, Diann E; Fitzgerald, Robert K; Faustino, Edward Vincent S
2018-05-01
To determine the prevailing hemoglobin levels in PICU patients, and any potential correlates. Post hoc analysis of prospective multicenter observational data. Fifty-nine PICUs in seven countries. PICU patients on four specific days in 2012. None. Patients' hemoglobin and other clinical and institutional data. Two thousand three hundred eighty-nine patients with median age of 1.9 years (interquartile range, 0.3-9.8 yr), weight 11.5 kg (interquartile range, 5.4-29.6 kg), and preceding PICU stay of 4.0 days (interquartile range, 1.0-13.0 d). Their median hemoglobin was 11.0 g/dL (interquartile range, 9.6-12.5 g/dL). The prevalence of transfusion in the 24 hours preceding data collection was 14.2%. Neonates had the highest hemoglobin at 13.1 g/dL (interquartile range, 11.2-15.0 g/dL) compared with other age groups (p < 0.001). The percentage of 31.3 of the patients had hemoglobin of greater than or equal to 12 g/dL, and 1.1% had hemoglobin of less than 7 g/dL. Blacks had lower median hemoglobin (10.5; interquartile range, 9.3-12.1 g/dL) compared with whites (median, 11.1; interquartile range, 9.0-12.6; p < 0.001). Patients in Spain and Portugal had the highest median hemoglobin (11.4; interquartile range, 10.0-12.6) compared with other regions outside of the United States (p < 0.001), and the highest proportion (31.3%) of transfused patients compared with all regions (p < 0.001). Patients in cardiac PICUs had higher median hemoglobin than those in mixed PICUs or noncardiac PICUs (12.3, 11.0, and 10.6 g/dL, respectively; p < 0.001). Cyanotic heart disease patients had the highest median hemoglobin (12.6 g/dL; interquartile range, 11.1-14.5). Multivariable regression analysis within diagnosis groups revealed that hemoglobin levels were significantly associated with the geographic location and history of complex cardiac disease in most of the models. In children with cancer, none of the variables tested correlated with patients' hemoglobin levels. Patients' hemoglobin levels correlated with demographics like age, race, geographic location, and cardiac disease, but none found in cancer patients. Future investigations should account for the effects of these variables.
Batagini, Nayara Cioffi; Ventura, Carlos Augusto Pinto; Raghavan, Madhavan L; Chammas, Maria Cristina; Tachibana, Adriano; da Silva, Erasmo Simão
2016-06-01
The objective was to demonstrate the ability of ultrasound (US) with 3D properties to evaluate volumetry and biomechanical parameters of the aorta in patients with and without abdominal aortic aneurysm (AAA). Thirty-one patients with normal aortas (group 1), 46 patients with AAA measuring 3.0-5.5 cm (group 2) and 31 patients with AAA ⩾ 5.5 cm (group 3) underwent a 2D/3D-US examination of the infra-renal aorta, and the images were post-processed prior to being analyzed. In the maximum diameter, the global circumferential strain and the global maximum rotation assessed by 2D speckle-tracking algorithms were compared among the three groups. The volumetry data obtained using 3D-US from 40 AAA patients were compared with the volumetry data obtained by a contemporary computed tomography (CT) scan. The median global circumferential strain was 2.0% (interquartile range (IR): 1.0-3.0), 1.0% (IR: 1.0-2.0) and 1.0% (IR: 1.0-1.75) in groups 1, 2 and 3, respectively (p < 0.001). The median global maximum rotation decreased progressively from group 1 to group 3 (1.38º (IR: 0.77-2.13), 0.80º (IR: 0.57-1.0) and 0.50º (IR: 0.31-0.75), p < 0.001). AAA volume estimations by 3D-US correlated well with CT (R(2) = 0.76). In conclusion, US with 3D properties is non-invasive and has the potential to evaluate volumetry and biomechanical characteristics of AAA. © The Author(s) 2016.
Percutaneous Dilational Tracheotomy in Solid-Organ Transplant Recipients.
Ozdemirkan, Aycan; Ersoy, Zeynep; Zeyneloglu, Pinar; Gedik, Ender; Pirat, Arash; Haberal, Mehmet
2015-11-01
Solid-organ transplant recipients may require percutaneous dilational tracheotomy because of prolonged mechanical ventilation or airway issues, but data regarding its safety and effectiveness in solid-organ transplant recipients are scarce. Here, we evaluated the safety, effectiveness, and benefits in terms of lung mechanics, complications, and patient comfort of percutaneous dilational tracheotomy in solid-organ transplant recipients. Medical records from 31 solid-organ transplant recipients (median age of 41.0 years [interquartile range, 18.0-53.0 y]) who underwent percutaneous dilational tracheotomy at our hospital between January 2010 and March 2015 were analyzed, including primary diagnosis, comorbidities, duration of orotracheal intubation and mechanical ventilation, length of intensive care unit and hospital stays, the time interval between transplant to percutaneous dilational tracheotomy, Acute Physiology and Chronic Health Evaluation II score, tracheotomy-related complications, and pulmonary compliance and ratio of partial pressure of arterial oxygen to fraction of inspired oxygen. The median Acute Physiology and Chronic Health Evaluation II score on admission was 24.0 (interquartile range, 18.0-29.0). The median interval from transplant to percutaneous dilational tracheotomy was 105.5 days (interquartile range, 13.0-2165.0 d). The only major complication noted was left-sided pneumothorax in 1 patient. There were no significant differences in ratio of partial pressure of arterial oxygen to fraction of inspired oxygen before and after procedure (170.0 [interquartile range, 102.2-302.0] vs 210.0 [interquartile range, 178.5-345.5]; P = .052). However, pulmonary compliance results preprocedure and postprocedure were significantly different (0.020 L/cm H2O [interquartile range, 0.015-0.030 L/cm H2O] vs 0.030 L/cm H2O [interquartile range, 0.020-0.041 L/cm H2O); P = .001]). Need for sedation significantly decreased after tracheotomy (from 17 patients [54.8%] to 8 patients [25.8%]; P = .004]). Percutaneous dilational tracheotomy with bronchoscopic guidance is an efficacious and safe technique for maintaining airways in solidorgan transplant recipients who require prolonged mechanical ventilation, resulting in possible improvements in ventilatory mechanics and patient comfort.
Shkirkova, Kristina; Akam, Eftitan Y; Huang, Josephine; Sheth, Sunil A; Nour, May; Liang, Conrad W; McManus, Michael; Trinh, Van; Duckwiler, Gary; Tarpley, Jason; Vinuela, Fernando; Saver, Jeffrey L
2017-12-01
Background Rapid dissemination and coordination of clinical and imaging data among multidisciplinary team members are essential for optimal acute stroke care. Aim To characterize the feasibility and utility of the Synapse Emergency Room mobile (Synapse ERm) informatics system. Methods We implemented the Synapse ERm system for integration of clinical data, computerized tomography, magnetic resonance, and catheter angiographic imaging, and real-time stroke team communications, in consecutive acute neurovascular patients at a Comprehensive Stroke Center. Results From May 2014 to October 2014, the Synapse ERm application was used by 33 stroke team members in 84 Code Stroke alerts. Patient age was 69.6 (±17.1), with 41.5% female. Final diagnosis was: ischemic stroke 64.6%, transient ischemic attack 7.3%, intracerebral hemorrhage 6.1%, and cerebrovascular-mimic 22.0%. Each patient Synapse ERm record was viewed by a median of 10 (interquartile range 6-18) times by a median of 3 (interquartile range 2-4) team members. The most used feature was computerized tomography, magnetic resonance, and catheter angiography image display. In-app tweet team, communications were sent by median 1 (interquartile range 0-1, range 0-13) users per case and viewed by median 1 (interquartile range 0-3, range 0-44) team members. Use of the system was associated with rapid treatment times, faster than national guidelines, including median door-to-needle 51.0 min (interquartile range 40.5-69.5) and median door-to-groin 94.5 min (interquartile range 85.5-121.3). In user surveys, the mobile information platform was judged easy to employ in 91% (95% confidence interval 65%-99%) of uses and of added help in stroke management in 50% (95% confidence interval 22%-78%). Conclusion The Synapse ERm mobile platform for stroke team distribution and integration of clinical and imaging data was feasible to implement, showed high ease of use, and moderate perceived added utility in therapeutic management.
Uber, Amy J; Perman, Sarah M; Cocchi, Michael N; Patel, Parth V; Ganley, Sarah E; Portmann, Jocelyn M; Donnino, Michael W; Grossestreuer, Anne V
2018-04-03
Assess if amount of heat generated by postcardiac arrest patients to reach target temperature (Ttarget) during targeted temperature management is associated with outcomes by serving as a proxy for thermoregulatory ability, and whether it modifies the relationship between time to Ttarget and outcomes. Retrospective cohort study. Urban tertiary-care hospital. Successfully resuscitated targeted temperature management-treated adult postarrest patients between 2008 and 2015 with serial temperature data and Ttarget less than or equal to 34°C. None. Time to Ttarget was defined as time from targeted temperature management initiation to first recorded patient temperature less than or equal to 34°C. Patient heat generation ("heat units") was calculated as inverse of average water temperature × hours between initiation and Ttarget × 100. Primary outcome was neurologic status measured by Cerebral Performance Category score; secondary outcome was survival, both at hospital discharge. Univariate analyses were performed using Wilcoxon rank-sum tests; multivariate analyses used logistic regression. Of 203 patients included, those with Cerebral Performance Category score 3-5 generated less heat before reaching Ttarget (median, 8.1 heat units [interquartile range, 3.6-21.6 heat units] vs median, 20.0 heat units [interquartile range, 9.0-33.5 heat units]; p = 0.001) and reached Ttarget quicker (median, 2.3 hr [interquartile range, 1.5-4.0 hr] vs median, 3.6 hr [interquartile range, 2.0-5.0 hr]; p = 0.01) than patients with Cerebral Performance Category score 1-2. Nonsurvivors generated less heat than survivors (median, 8.1 heat units [interquartile range, 3.6-20.8 heat units] vs median, 19.0 heat units [interquartile range, 6.5-33.5 heat units]; p = 0.001) and reached Ttarget quicker (median, 2.2 hr [interquartile range, 1.5-3.8 hr] vs median, 3.6 hr [interquartile range, 2.0-5.0 hr]; p = 0.01). Controlling for average water temperature between initiation and Ttarget, the relationship between outcomes and time to Ttarget was no longer significant. Controlling for location, witnessed arrest, age, initial rhythm, and neuromuscular blockade use, increased heat generation was associated with better neurologic (adjusted odds ratio, 1.01 [95% CI, 1.00-1.03]; p = 0.039) and survival (adjusted odds ratio, 1.01 [95% CI, 1.00-1.03]; p = 0.045) outcomes. Increased heat generation during targeted temperature management initiation is associated with better outcomes at hospital discharge and may affect the relationship between time to Ttarget and outcomes.
Braithwaite, Susan S.; Godara, Hemant; Song, Julie; Cairns, Bruce A.; Jones, Samuel W.; Umpierrez, Guillermo E.
2009-01-01
Background Algorithms for intravenous insulin infusion may assign the infusion rate (IR) by a two-step process. First, the previous insulin infusion rate (IRprevious) and the rate of change of blood glucose (BG) from the previous iteration of the algorithm are used to estimate the maintenance rate (MR) of insulin infusion. Second, the insulin IR for the next iteration (IRnext) is assigned to be commensurate with the MR and the distance of the current blood glucose (BGcurrent) from target. With use of a specific set of algorithm parameter values, a family of iso-MR curves is created, each giving IR as a function of MR and BG. Method To test the feasibility of estimating MR from the IRprevious and the previous rate of change of BG, historical hyperglycemic data points were used to compute the “maintenance rate cross step next estimate” (MRcsne). Historical cases had been treated with intravenous insulin infusion using a tabular protocol that estimated MR according to column-change rules. The mean IR on historical stable intervals (MRtrue), an estimate of the biologic value of MR, was compared to MRcsne during the hyperglycemic iteration immediately preceding the stable interval. Hypothetically calculated MRcsne-dependent IRnext was compared to IRnext assigned historically. An expanded theory of an algorithm is developed mathematically. Practical recommendations for computerization are proposed. Results The MRtrue determined on each of 30 stable intervals and the MRcsne during the immediately preceding hyperglycemic iteration differed, having medians with interquartile ranges 2.7 (1.2–3.7) and 3.2 (1.5–4.6) units/h, respectively. However, these estimates of MR were strongly correlated (R2 = 0.88). During hyperglycemia at 941 time points the IRnext assigned historically and the hypothetically calculated MRcsne-dependent IRnext differed, having medians with interquartile ranges 4.0 (3.0–6.0) and 4.6 (3.0–6.8) units/h, respectively, but these paired values again were correlated (R2 = 0.87). This article describes a programmable algorithm for intravenous insulin infusion. The fundamental equation of the algorithm gives the relationship among IR; the biologic parameter MR; and two variables expressing an instantaneous rate of change of BG, one of which must be zero at any given point in time and the other positive, negative, or zero, namely the rate of change of BG from below target (rate of ascent) and the rate of change of BG from above target (rate of descent). In addition to user-definable parameters, three special algorithm parameters discoverable in nature are described: the maximum rate of the spontaneous ascent of blood glucose during nonhypoglycemia, the glucose per daily dose of insulin exogenously mediated, and the MR at given patient time points. User-assignable parameters will facilitate adaptation to different patient populations. Conclusions An algorithm is described that estimates MR prior to the attainment of euglycemia and computes MR-dependent values for IRnext. Design features address glycemic variability, promote safety with respect to hypoglycemia, and define a method for specifying glycemic targets that are allowed to differ according to patient condition. PMID:20144334
Intestinal cytokines in children with pervasive developmental disorders.
DeFelice, Magee L; Ruchelli, Eduardo D; Markowitz, Jonathan E; Strogatz, Melissa; Reddy, Krishna P; Kadivar, Khadijeh; Mulberg, Andrew E; Brown, Kurt A
2003-08-01
A relationship between autism and gastrointestinal (GI) immune dysregulation has been postulated based on incidence of GI complaints as well as macroscopically observed lymphonodular hyperplasia and microscopically determined enterocolitis in pediatric patients with autism. To evaluate GI immunity, we quantitatively assessed levels of proinflammatory cytokines, interleukin (IL)-6, IL-8, and IL-1beta, produced by intestinal biopsies of children with pervasive developmental disorders. Fifteen patients, six with pervasive developmental disorders and nine age-matched controls, presenting for diagnostic colonoscopy were enrolled. Endoscopic biopsies were organ cultured, supernatants were harvested, and IL-6, IL-8, and IL-1beta levels were quantified by ELISA. Tissue histology was evaluated by blinded pathologists. Concentrations of IL-6 from intestinal organ culture supernatants of patients with pervasive developmental disorders (median 318.5 pg/ml, interquartile range 282.0-393.0 pg/ml) when compared with controls (median 436.9 pg/ml, interquartile range 312.6-602.5 pg/ml) were not significantly different (p = 0.0987). Concentrations of IL-8 (median 84,000 pg/ml, interquartile range 16,000-143,000 pg/ml) when compared with controls (median 177,000 pg/ml, interquartile range 114,000-244,000 pg/ml) were not significantly different (p = 0.0707). Concentrations of IL-1beta (median 0.0 pg/ml, interquartile range 0.0-94.7 pg/ml) when compared with controls (median 0.0 pg/ml, interquartile range 0.0-60.2 pg/ml) were not significantly different (p = 0.8826). Tissue histology was nonpathological for all patients. We have demonstrated no significant difference in production of IL-6, IL-8, and IL-1beta between patients with pervasive developmental disorders and age-matched controls. In general, intestinal levels of IL-6 and IL-8 were lower in patients with pervasive developmental disorders than in age-matched controls. These data fail to support an association between autism and GI inflammation.
Evaluation of an artificial intelligence program for estimating occupational exposures.
Johnston, Karen L; Phillips, Margaret L; Esmen, Nurtan A; Hall, Thomas A
2005-03-01
Estimation and Assessment of Substance Exposure (EASE) is an artificial intelligence program developed by UK's Health and Safety Executive to assess exposure. EASE computes estimated airborne concentrations based on a substance's vapor pressure and the types of controls in the work area. Though EASE is intended only to make broad predictions of exposure from occupational environments, some occupational hygienists might attempt to use EASE for individual exposure characterizations. This study investigated whether EASE would accurately predict actual sampling results from a chemical manufacturing process. Personal breathing zone time-weighted average (TWA) monitoring data for two volatile organic chemicals--a common solvent (toluene) and a specialty monomer (chloroprene)--present in this manufacturing process were compared to EASE-generated estimates. EASE-estimated concentrations for specific tasks were weighted by task durations reported in the monitoring record to yield TWA estimates from EASE that could be directly compared to the measured TWA data. Two hundred and six chloroprene and toluene full-shift personal samples were selected from eight areas of this manufacturing process. The Spearman correlation between EASE TWA estimates and measured TWA values was 0.55 for chloroprene and 0.44 for toluene, indicating moderate predictive values for both compounds. For toluene, the interquartile range of EASE estimates at least partially overlapped the interquartile range of the measured data distributions in all process areas. The interquartile range of EASE estimates for chloroprene fell above the interquartile range of the measured data distributions in one process area, partially overlapped the third quartile of the measured data in five process areas and fell within the interquartile range in two process areas. EASE is not a substitute for actual exposure monitoring. However, EASE can be used in conditions that cannot otherwise be sampled and in preliminary exposure assessment if it is recognized that the actual interquartile range could be much wider and/or offset by a factor of 10 or more.
Variability in Antibiotic Use Across PICUs.
Brogan, Thomas V; Thurm, Cary; Hersh, Adam L; Gerber, Jeffrey S; Smith, Michael J; Shah, Samir S; Courter, Joshua D; Patel, Sameer J; Parker, Sarah K; Kronman, Matthew P; Lee, Brian R; Newland, Jason G
2018-06-01
To characterize and compare antibiotic prescribing across PICUs to evaluate the degree of variability. Retrospective analysis from 2010 through 2014 of the Pediatric Health Information System. Forty-one freestanding children's hospital. Children aged 30 days to 18 years admitted to a PICU in children's hospitals contributing data to Pediatric Health Information System. To normalize for potential differences in disease severity and case mix across centers, a subanalysis was performed of children admitted with one of the 20 All Patient Refined-Diagnosis Related Groups and the seven All Patient Refined-Diagnosis Related Groups shared by all PICUs with the highest antibiotic use. The study included 3,101,201 hospital discharges from 41 institutions with 386,914 PICU patients. All antibiotic use declined during the study period. The median-adjusted antibiotic use among PICU patients was 1,043 days of therapy/1,000 patient-days (interquartile range, 977-1,147 days of therapy/1,000 patient-days) compared with 893 among non-ICU children (interquartile range, 805-968 days of therapy/1,000 patient-days). For PICU patients, the median adjusted use of broad-spectrum antibiotics was 176 days of therapy/1,000 patient-days (interquartile range, 152-217 days of therapy/1,000 patient-days) and was 302 days of therapy/1,000 patient-days (interquartile range, 220-351 days of therapy/1,000 patient-days) for antimethicillin-resistant Staphylococcus aureus agents, compared with 153 days of therapy/1,000 patient-days (interquartile range, 130-182 days of therapy/1,000 patient-days) and 244 days of therapy/1,000 patient-days (interquartile range, 203-270 days of therapy/1,000 patient-days) for non-ICU children. After adjusting for potential confounders, significant institutional variability existed in antibiotic use in PICU patients, in the 20 All Patient Refined-Diagnosis Related Groups with the highest antibiotic usage and in the seven All Patient Refined-Diagnosis Related Groups shared by all 41 PICUs. The wide variation in antibiotic use observed across children's hospital PICUs suggests inappropriate antibiotic use.
Grau-Perez, Maria; Kuo, Chin-Chi; Gribble, Matthew O; Balakrishnan, Poojitha; Jones Spratlen, Miranda; Vaidya, Dhananjay; Francesconi, Kevin A; Goessler, Walter; Guallar, Eliseo; Silbergeld, Ellen K; Umans, Jason G; Best, Lyle G; Lee, Elisa T; Howard, Barbara V; Cole, Shelley A; Navas-Acien, Ana
2017-12-20
High arsenic exposure has been related to diabetes, but at low-moderate levels the evidence is mixed. Arsenic metabolism, which is partly genetically controlled and may rely on certain B vitamins, plays a role in arsenic toxicity. We evaluated the prospective association of arsenic exposure and metabolism with type 2 diabetes and insulin resistance. We included 1,838 American Indian men and women free of diabetes (median age, 36 y). Arsenic exposure was assessed as the sum of inorganic arsenic (iAs), monomethylarsonate (MMA), and dimethylarsinate (DMA) urine concentrations (ΣAs). Arsenic metabolism was evaluated by the proportions of iAs, MMA, and DMA over their sum (iAs%, MMA%, and DMA%). Homeostasis model assessment for insulin resistance (HOMA2-IR) was measured at baseline and follow-up visits. Incident diabetes was evaluated at follow-up. Median ΣAs, iAs%, MMA%, and DMA% was 4.4 μg/g creatinine, 9.5%, 14.4%, and 75.6%, respectively. Over 10,327 person-years of follow-up, 252 participants developed diabetes. Median HOMA2-IR at baseline was 1.5. The fully adjusted hazard ratio [95% confidence interval (CI)] for incident diabetes per an interquartile range increase in ΣAs was 1.57 (95% CI: 1.18, 2.08) in participants without prediabetes at baseline. Arsenic metabolism was not associated with incident diabetes. ΣAs was positively associated with HOMA2-IR at baseline but negatively with HOMA2-IR at follow-up. Increased MMA% was associated with lower HOMA2-IR when either iAs% or DMA% decreased. The association of arsenic metabolism with HOMA2-IR differed by B-vitamin intake and AS3MT genetics variants. Among participants without baseline prediabetes, arsenic exposure was associated with incident diabetes. Low MMA% was cross-sectional and prospectively associated with higher HOMA2-IR. Research is needed to confirm possible interactions of arsenic metabolism with B vitamins and AS3MT variants on diabetes risk. https://doi.org/10.1289/EHP2566.
Kuo, Chin-Chi; Gribble, Matthew O.; Balakrishnan, Poojitha; Jones Spratlen, Miranda; Vaidya, Dhananjay; Francesconi, Kevin A.; Goessler, Walter; Guallar, Eliseo; Silbergeld, Ellen K.; Umans, Jason G.; Best, Lyle G.; Lee, Elisa T.; Howard, Barbara V.; Cole, Shelley A.
2017-01-01
Background: High arsenic exposure has been related to diabetes, but at low-moderate levels the evidence is mixed. Arsenic metabolism, which is partly genetically controlled and may rely on certain B vitamins, plays a role in arsenic toxicity. Objective: We evaluated the prospective association of arsenic exposure and metabolism with type 2 diabetes and insulin resistance. Methods: We included 1,838 American Indian men and women free of diabetes (median age, 36 y). Arsenic exposure was assessed as the sum of inorganic arsenic (iAs), monomethylarsonate (MMA), and dimethylarsinate (DMA) urine concentrations (ΣAs). Arsenic metabolism was evaluated by the proportions of iAs, MMA, and DMA over their sum (iAs%, MMA%, and DMA%). Homeostasis model assessment for insulin resistance (HOMA2-IR) was measured at baseline and follow-up visits. Incident diabetes was evaluated at follow-up. Results: Median ΣAs, iAs%, MMA%, and DMA% was 4.4μg/g creatinine, 9.5%, 14.4%, and 75.6%, respectively. Over 10,327 person-years of follow-up, 252 participants developed diabetes. Median HOMA2-IR at baseline was 1.5. The fully adjusted hazard ratio [95% confidence interval (CI)] for incident diabetes per an interquartile range increase in ΣAs was 1.57 (95% CI: 1.18, 2.08) in participants without prediabetes at baseline. Arsenic metabolism was not associated with incident diabetes. ΣAs was positively associated with HOMA2-IR at baseline but negatively with HOMA2-IR at follow-up. Increased MMA% was associated with lower HOMA2-IR when either iAs% or DMA% decreased. The association of arsenic metabolism with HOMA2-IR differed by B-vitamin intake and AS3MT genetics variants. Conclusions: Among participants without baseline prediabetes, arsenic exposure was associated with incident diabetes. Low MMA% was cross-sectional and prospectively associated with higher HOMA2-IR. Research is needed to confirm possible interactions of arsenic metabolism with B vitamins and AS3MT variants on diabetes risk. https://doi.org/10.1289/EHP2566 PMID:29373862
Early-Life Exposure to Perfluoroalkyl Substances and Childhood Metabolic Function.
Fleisch, Abby F; Rifas-Shiman, Sheryl L; Mora, Ana M; Calafat, Antonia M; Ye, Xiaoyun; Luttmann-Gibson, Heike; Gillman, Matthew W; Oken, Emily; Sagiv, Sharon K
2017-03-01
Perfluoroalkyl substances (PFASs) are synthetic chemicals that may persist in the environment and in humans. There is a possible association between early-life PFAS exposure and metabolic dysfunction in later life, but data are limited. We studied 665 mother-child pairs in Project Viva, a Boston, Massachusetts-area cohort recruited 1999-2002. We quantified concentrations of PFASs [perfluorooctanoate (PFOA), perfluorooctane sulfonate (PFOS), perfluorononanoate (PFNA), perfluorohexane sulfonate (PFHxS), and perfluorodecanoate (PFDeA)] in maternal plasma collected at the first prenatal visit (median, 9.6 weeks gestation) and in child plasma from the mid-childhood research visit (median, 7.7 years). We assessed leptin, adiponectin, and homeostatic model assessment of insulin resistance (HOMA-IR) in mid-childhood. We fit covariate-adjusted linear regression models and conducted stratified analyses by child sex. Children with higher PFAS concentrations had lower HOMA-IR [e.g., -10.1% (95% CI: -17.3, -2.3) per interquartile range increment in PFOA]. This inverse association between child PFAS and HOMA-IR was more pronounced in females [e.g., PFOA: -15.6% (95% CI: -25.4, -4.6) vs. -6.1% (95% CI: -16.2, 5.2) for males]. Child PFAS plasma concentrations were not associated with leptin or adiponectin. Prenatal PFAS plasma concentrations were not associated with leptin, adiponectin, or HOMA-IR in offspring. We found no evidence for an adverse effect of early-life PFAS exposure on metabolic function in mid-childhood. In fact, children with higher PFAS concentrations had lower insulin resistance. Citation: Fleisch AF, Rifas-Shiman SL, Mora AM, Calafat AM, Ye X, Luttmann-Gibson H, Gillman MW, Oken E, Sagiv SK. 2017. Early-life exposure to perfluoroalkyl substances and childhood metabolic function. Environ Health Perspect 125:481-487; http://dx.doi.org/10.1289/EHP303.
Single-Incision Laparoscopic Sterilization of the Cheetah (Acinonyx jubatus).
Hartman, Marthinus J; Monnet, Eric; Kirberger, Robert M; Schmidt-Küntzel, Anne; Schulman, Martin L; Stander, Jana A; Stegmann, George F; Schoeman, Johan P
2015-07-01
To describe laparoscopic ovariectomy and salpingectomy in the cheetah (Acinonyx jubatus) using single-incision laparoscopic surgery (SILS). Prospective cohort. Female cheetahs (Acinonyx jubatus) (n = 21). Cheetahs were randomly divided to receive either ovariectomy (n = 11) or salpingectomy (n = 10). The use and complications of a SILS port was evaluated in all of cheetahs. Surgery duration and insufflation volumes of carbon dioxide (CO2 ) were recorded and compared across procedures. Laparoscopic ovariectomy and salpingectomy were performed without complications using a SILS port. The poorly-developed mesosalpinx and ovarian bursa facilitated access to the uterine tube for salpingectomy in the cheetah. The median surgery duration for ovariectomy was 24 minutes (interquartile range 3) and for salpingectomy was 19.5 minutes (interquartile range 3) (P = .005). The median volume of CO2 used for ovariectomy was 11.25 L (interquartile range 3.08) and for salpingectomy was 4.90 L (interquartile range 2.52), (P = .001) CONCLUSIONS: Laparoscopic ovariectomy and salpingectomy can be performed in the cheetah using SILS without perioperative complications. Salpingectomy is faster than ovariectomy and requires less total CO2 for insufflation. © Copyright 2015 by The American College of Veterinary Surgeons.
Jing, Jing; Pan, Yuesong; Zhao, Xingquan; Zheng, Huaguang; Jia, Qian; Mi, Donghua; Chen, Weiqi; Li, Hao; Liu, Liping; Wang, Chunxue; He, Yan; Wang, David; Wang, Yilong; Wang, Yongjun
2017-04-01
Insulin resistance was common in patients with stroke. This study investigated the association between insulin resistance and outcomes in nondiabetic patients with first-ever acute ischemic stroke. Patients with ischemic stroke without history of diabetes mellitus in the ACROSS-China registry (Abnormal Glucose Regulation in Patients With Acute Stroke Across China) were included. Insulin resistance was defined as a homeostatis model assessment-insulin resistance (HOMA-IR) index in the top quartile (Q4). HOMA-IR was calculated as fasting insulin (μU/mL)×fasting glucose (mmol/L)/22.5. Multivariable logistic regression or Cox regression was performed to estimate the association between HOMA-IR and 1-year prognosis (mortality, stroke recurrence, poor functional outcome [modified Rankin scale score 3-6], and dependence [modified Rankin scale score 3-5]). Among the 1245 patients with acute ischemic stroke enrolled in this study, the median HOMA-IR was 1.9 (interquartile range, 1.1-3.1). Patients with insulin resistance were associated with a higher mortality risk than those without (adjusted hazard ratio, 1.68; 95% confidence interval, 1.12-2.53; P =0.01), stroke recurrence (adjusted hazard ratio, 1.57, 95% confidence interval, 1.12-2.19; P =0.008), and poor outcome (adjusted odds ratio, 1.42; 95% confidence interval, 1.03-1.95; P =0.03) but not dependence after adjustment for potential confounders. Higher HOMA-IR quartile categories were associated with a higher risk of 1-year death, stroke recurrence, and poor outcome ( P for trend =0.005, 0.005, and 0.001, respectively). Insulin resistance was associated with an increased risk of death, stroke recurrence, and poor outcome but not dependence in nondiabetic patients with acute ischemic stroke. © 2017 American Heart Association, Inc.
Ma, Xiaojing; Hao, Yaping; Hu, Xiang; Luo, Yuqi; Deng, Zixuan; Zhou, Jian; Bao, Yuqian; Jia, Weiping
2015-05-01
The goal of the present study was to explore the correlations of 1,5-anhydroglucitol (l,5-AG), glycated hemoglobin (HbA1c), and glycated albumin (GA) with insulin sensitivity and secretion. In total, 302 patients with newly diagnosed type 2 diabetes mellitus (166 men, 136 women) were enrolled in this study. The homeostasis model assessment for insulin resistance (HOMA-IR) and homeostasis model assessment for β-cell function (HOMA-β) were calculated to determine the basal insulin sensitivity and secretion. The insulinogenic index (IGI) was used to evaluate early-phase insulin secretion. 1,5-AG and GA were assayed via the enzymatic method, and HbA1c was detected by high-pressure liquid chromatography. Among all 302 subjects, the serum 1,5-AG level was 13.1±7.2 μg/mL, and the HbA1c and GA levels [median (interquartile range)] were 6.7% (6.2-7.3%) and 17.7% (16.0-19.5%), respectively. Increased 1,5-AG quartiles were accompanied by trends toward a decreased HOMA-IR and an increased HOMA-β and IGI (for all trends, P<0.001). 1,5-AG was negatively associated with HOMA-IR (r=-0.200, P<0.001) and positively associated with HOMA-β and IGI (r=0.210 and 0.413, respectively; both P<0.001). 1,5-AG was independently related to HOMA-IR and HOMA-β and exhibited an independent positive association with IGI (standardized β=0.242, P<0.001). Additionally, both HbA1c and GA were independently correlated with HOMA-IR and HOMA-β. 1,5-AG is not only correlated with basal insulin sensitivity and secretion, but also closely associated with early-phase insulin secretion in Chinese patients with newly diagnosed type 2 diabetes mellitus.
Rosa, Regis Goulart; Tonietto, Tulio Frederico; da Silva, Daiana Barbosa; Gutierres, Franciele Aparecida; Ascoli, Aline Maria; Madeira, Laura Cordeiro; Rutzen, William; Falavigna, Maicon; Robinson, Caroline Cabral; Salluh, Jorge Ibrain; Cavalcanti, Alexandre Biasi; Azevedo, Luciano Cesar; Cremonese, Rafael Viegas; Haack, Tarissa Ribeiro; Eugênio, Cláudia Severgnini; Dornelles, Aline; Bessel, Marina; Teles, José Mario Meira; Skrobik, Yoanna; Teixeira, Cassiano
2017-10-01
To evaluate the effect of an extended visitation model compared with a restricted visitation model on the occurrence of delirium among ICU patients. Prospective single-center before and after study. Thirty-one-bed medical-surgical ICU. All patients greater than or equal to 18 years old with expected length of stay greater than or equal to 24 hours consecutively admitted to the ICU from May 2015 to November 2015. Change of visitation policy from a restricted visitation model (4.5 hr/d) to an extended visitation model (12 hr/d). Two hundred eighty-six patients were enrolled (141 restricted visitation model, 145 extended visitation model). The primary outcome was the cumulative incidence of delirium, assessed bid using the confusion assessment method for the ICU. Predefined secondary outcomes included duration of delirium/coma; any ICU-acquired infection; ICU-acquired bloodstream infection, pneumonia, and urinary tract infection; all-cause ICU mortality; and length of ICU stay. The median duration of visits increased from 133 minutes (interquartile range, 97.7-162.0) in restricted visitation model to 245 minutes (interquartile range, 175.0-272.0) in extended visitation model (p < 0.001). Fourteen patients (9.6%) developed delirium in extended visitation model compared with 29 (20.5%) in restricted visitation model (adjusted relative risk, 0.50; 95% CI, 0.26-0.95). In comparison with restricted visitation model patients, extended visitation model patients had shorter length of delirium/coma (1.5 d [interquartile range, 1.0-3.0] vs 3.0 d [interquartile range, 2.5-5.0]; p = 0.03) and ICU stay (3.0 d [interquartile range, 2.0-4.0] vs 4.0 d [interquartile range, 2.0-6.0]; p = 0.04). The rate of ICU-acquired infections and all-cause ICU mortality did not differ significantly between the two study groups. In this medical-surgical ICU, an extended visitation model was associated with reduced occurrence of delirium and shorter length of delirium/coma and ICU stay.
Evidence for activation of nuclear factor kappaB in obstructive sleep apnea.
Yamauchi, Motoo; Tamaki, Shinji; Tomoda, Koichi; Yoshikawa, Masanori; Fukuoka, Atsuhiko; Makinodan, Kiyoshi; Koyama, Noriko; Suzuki, Takahiro; Kimura, Hiroshi
2006-12-01
Obstructive sleep apnea (OSA) is a risk factor for atherosclerosis, and atherosclerosis evolves from activation of the inflammatory cascade. We propose that activation of the nuclear factor kappaB (NF-kappaB), a key transcription factor in the inflammatory cascade, occurs in OSA. Nine age-matched, nonsmoking, and non-hypertensive men with OSA symptoms and seven similar healthy subjects were recruited for standard polysomnography followed by the collection of blood samples for monocyte nuclear p65 concentrations (OSA and healthy groups). In the OSA group, p65 and of monocyte production of tumor necrosis factor alpha (TNF-alpha) were measured at the same time and after the next night of continuous positive airway pressure (CPAP). p65 Concentrations in the OSA group were significantly higher than in the control group [median, 0.037 ng/microl (interquartile range, 0.034 to 0.051) vs 0.019 ng/microl (interquartile range, 0.013 to 0.032); p = 0.008], and in the OSA group were significantly correlated with apnea-hypopnea index and time spent below an oxygen saturation of 90% (r = 0.77 and 0.88, respectively) after adjustment for age and BMI. One night of CPAP resulted in a reduction in p65 [to 0.020 ng/mul (interquartile range, 0.010 to 0.036), p = 0.04] and levels of TNF-alpha production in cultured monocytes [16.26 (interquartile range, 7.75 to 24.85) to 7.59 ng/ml (interquartile range, 5.19 to 12.95), p = 0.01]. NF-kappaB activation occurs with sleep-disordered breathing. Such activation of NF-kappaB may contribute to the pathogenesis of atherosclerosis in OSA patients.
Palkovits, Stefan; Seidel, Gerald; Pertl, Laura; Malle, Eva M; Hausberger, Silke; Makk, Johanna; Singer, Christoph; Osterholt, Julia; Herzog, Sereina A; Haas, Anton; Weger, Martin
2017-12-01
To evaluate the effect of intravitreal bevacizumab on the macular choroidal volume and the subfoveal choroidal thickness in treatment naïve eyes with exudative age-related macular degeneration. The macular choroidal volume and the subfoveal choroidal thickness were measured using enhanced depth imaging optical coherence tomography. After a screening examination, each patient received 3 monthly intravitreal injections of 1.25 mg bevacizumab. One month after the third injection was a final assessment. Forty-seven patients with a mean age of 80 ± 6.4 years were included. The macular choroidal volume decreased significantly from median 4.1 mm (interquartile range 3.4-5.9) to median 3.9 mm (interquartile range 3.1-5.6) between the baseline and final examination (difference -0.46 mm, 95% confidence interval: -0.57 to 0.35, P < 0.001). Similarly, subfoveal choroidal thickness had decreased from 157.0 μm (interquartile range 116.0-244.5) at baseline to 139.0 μm (interquartile range 102.5-212.0) at the final examination (P < 0.001). Both parameters macular choroidal volume at baseline and subfoveal choroidal thickness at baseline were not associated with the response to treatment. The macular choroidal volume and the subfoveal choroidal thickness decreased significantly after 3 monthly bevacizumab injections for exudative age-related macular degeneration.
Bornman, Riana M.S.; Archer, Janet I.; Kudumu, Mwenda O.; Travlos, Gregory S.; Wilson, Ralph E.; Longnecker, Matthew P.
2014-01-01
Background: Few studies have examined predictors of DDT (dichlorodiphenyltrichloroethane) and DDE (dichlorodiphenyldichloroethylene) levels among residents in homes sprayed with DDT for malaria control with the aim of identifying exposure-reduction strategies. Methods: The present analysis included 381 women enrolled in the Study of Women and Babies (SOWB) during 2010–2011, from eight South African villages in the Limpopo Province, South Africa. Indoor residual spraying (IRS) occurred in half of the villages. Questionnaires regarding various demographic and medical factors were administered and blood samples were obtained. We classified the women into three exposure groups by type of residence: unsprayed village (n = 175), IRS village in household with a low likelihood of DDT use (non-DDT IRS household, n = 106), IRS village in household with a high likelihood of DDT use (DDT IRS household, n = 100). We used multivariable models of natural log-transformed DDT plasma levels (in micrograms per liter) and DDE (in micrograms per liter) to identify predictors for each group. Results: Median levels of DDT and DDE among women in unsprayed villages were 0.3 [interquartile range (IQR): 0.1–0.9] and 1.7 (IQR: 0.7–5.5), respectively. Median levels of DDT and DDE among women in DDT IRS households were 2.6 (IQR: 1.1–6.6) and 8.5 (IQR: 4.7–18.0), respectively. In unsprayed villages, women with water piped to the yard, rather than a public tap, had 73% lower DDT (95% CI: –83, –57%) and 61% lower DDE (95% CI: –74, –40%) levels. In DDT IRS households, women who reported taking more than six actions to prepare their home before IRS (e.g., covering water and food) had 40% lower DDT levels (95% CI: –63, –0.3%) than women who took fewer than four actions. Conclusion: The predictors of DDT and DDE plasma levels identified in the present study may inform interventions aimed at decreasing exposure. Among households where DDT is likely to be used for IRS, education regarding home preparations may provide an interventional target. Citation: Whitworth KW, Bornman RM, Archer JI, Kudumu MO, Travlos GS, Wilson RE, Longnecker MP. 2014. Predictors of plasma DDT and DDE concentrations among women exposed to indoor residual spraying for malaria control in the South African Study of Women and Babies (SOWB). Environ Health Perspect 122:545–552; http://dx.doi.org/10.1289/ehp.1307025 PMID:24577839
Lin, Yucong; Xu, Xijin; Dai, Yifeng; Zhang, Yuling; Li, Weiqiu; Huo, Xia
2016-12-15
Data on vaccination effects in children chronically exposed to heavy metals are extremely scarce. This study aims to investigate the immune responsiveness to measles, mumps, and rubella (MMR) vaccination in children from an e-waste recycling area. 378 healthy children from Guiyu (exposed group) and Haojiang (reference group) were surveyed. Blood lead (Pb) levels were measured by graphite furnace atomic absorption. Titers of antibodies against MMR were quantified by ELISA. Blood Pb levels of children from the exposed group were significantly higher than those from the reference group (5.61μg/dL vs. 3.57μg/dL, p<0.001). In contrast, the antibody titers against MMR of the children from the exposed group were significantly lower than those from the reference group. The median titer of the anti-measles antibody of the exposed group was 669.64mIU/mL, with an interquartile range of 372.88-1068.42mIU/mL; this was decreased by nearly 40% compared to that of the reference group (median 1046.79mIU/mL, interquartile range 603.29-1733.10mIU/mL). For antibody titers against mumps, there was an about 45% decrease in the exposed group (median 272.24U/mL, interquartile range 95.19-590.16U/mL), compared to the reference group (median 491.78U/mL, interquartile range 183.38-945.96U/mL). In the case of rubella, the median titer of the antibody was also significantly lower in the exposed group (median 37.08IU/mL, interquartile range 17.67-66.66IU/mL) compared to the reference group (median 66.50IU/mL, interquartile range 25.32-105.59IU/mL); the decrease in this case was nearly 44%. The proportion of children whose antibody titers against MMR were below protective level in the exposed group was higher than it was in the reference group. The present study demonstrates that the immune responsiveness to routine vaccination was suppressed in children chronically exposed to lead. Thus, the vaccination strategies for these children living in an e-waste recycling area should be modified. Copyright © 2016. Published by Elsevier B.V.
Grignard, Lynn; Gonçalves, Bronner P; Early, Angela M; Daniels, Rachel F; Tiono, Alfred B; Guelbéogo, Wamdaogo M; Ouédraogo, Alphonse; van Veen, Elke M; Lanke, Kjerstin; Diarra, Amidou; Nebie, Issa; Sirima, Sodiomon B; Targett, Geoff A; Volkman, Sarah K; Neafsey, Daniel E; Wirth, Dyann F; Bousema, Teun; Drakeley, Chris
2018-05-05
Plasmodium falciparum malaria infections often comprise multiple distinct parasite clones. Few datasets have directly assessed infection complexity in humans and mosquitoes they infect. Examining parasites using molecular tools may provide insights into the selective transmissibility of isolates. Using capillary electrophoresis genotyping and next generation amplicon sequencing, we analysed complexity of parasite infections in human blood and in the midguts of mosquitoes that became infected in membrane feeding experiments using the same blood material in two West African settings. Median numbers of clones in humans and mosquitoes were higher in samples from Burkina Faso (4.5, interquartile range 2-8 for humans; and 2, interquartile range 1-3 for mosquitoes) than in The Gambia (2, interquartile range 1-3 and 1, interquartile range 1-3, for humans and mosquitoes, respectively). Whilst the median number of clones was commonly higher in human blood samples, not all transmitted alleles were detectable in the human peripheral blood. In both study sample sets, additional parasite alleles were identified in mosquitoes compared with the matched human samples (10-88.9% of all clones/feeding assay, n = 73 feeding assays). The results are likely due to preferential amplification of the most abundant clones in peripheral blood but confirm the presence of low density clones that produce transmissible sexual stage parasites. Copyright © 2018. Published by Elsevier Ltd.
Serum Fatty Acid Binding Protein 4 (FABP4) Predicts Pre-eclampsia in Women With Type 1 Diabetes.
Wotherspoon, Amy C; Young, Ian S; McCance, David R; Patterson, Chris C; Maresh, Michael J A; Pearson, Donald W M; Walker, James D; Holmes, Valerie A
2016-10-01
To examine the association between fatty acid binding protein 4 (FABP4) and pre-eclampsia risk in women with type 1 diabetes. Serum FABP4 was measured in 710 women from the Diabetes and Pre-eclampsia Intervention Trial (DAPIT) in early pregnancy and in the second trimester (median 14 and 26 weeks' gestation, respectively). FABP4 was significantly elevated in early pregnancy (geometric mean 15.8 ng/mL [interquartile range 11.6-21.4] vs. 12.7 ng/mL [interquartile range 9.6-17]; P < 0.001) and the second trimester (18.8 ng/mL [interquartile range 13.6-25.8] vs. 14.6 ng/mL [interquartile range 10.8-19.7]; P < 0.001) in women in whom pre-eclampsia later developed. Elevated second-trimester FABP4 level was independently associated with pre-eclampsia (odds ratio 2.87 [95% CI 1.24-6.68], P = 0.03). The addition of FABP4 to established risk factors significantly improved net reclassification improvement at both time points and integrated discrimination improvement in the second trimester. Increased second-trimester FABP4 independently predicted pre-eclampsia and significantly improved reclassification and discrimination. FABP4 shows potential as a novel biomarker for pre-eclampsia prediction in women with type 1 diabetes. © 2016 by the American Diabetes Association.
Tominaga, Ryoji; Sekiguchi, Miho; Yonemoto, Koji; Kakuma, Tatsuyuki; Konno, Shin-Ichi
2018-05-01
The Japanese Orthopaedic Association Back Pain Evaluation Questionnaire (JOABPEQ) was developed in 2007, including the five domains of Pain-related disorder, Lumbar spine dysfunction, Gait disturbance, Social life disturbance, and Psychological disorder. It is used by physicians to evaluate treatment efficacy by comparing scores before and after treatment. However, the JOABPEQ does not allow evaluation of the severity of a patient's condition compared to the general population at a single time point. Given the unavailability of a standard measurement of back pain, we sought to establish reference scores and interquartile ranges using data obtained from a multicenter, cross-sectional survey taken in Japanese primary care settings. The Lumbar Spinal Stenosis Diagnosis Support Tool project was conducted from 2011 to 2012 in 1657 hospitals in Japan to investigate the establishment of reference scores using JOABPEQ. Patients aged ≥ 20 years undergoing medical examinations by either non-orthopaedic primary care physicians or general orthopedists were considered for enrollment. A total of 10,651 consecutive low back pain patients (5331 men, 5320 women, 18 subjects with missing sex data) who had undergone a medical examination were included. Reference scores and interquartile ranges for each of the five domains of the JOABPEQ according to age and sex were recorded. The median score and interquartile range are the same in the domain of Pain-related disorder in all ages and sexes. The reference scores for Gait disturbance, Social life disturbance and Psychological disorder declined with increasing age in both age- and sex-stratified groups, while there was some different trend in Lumbar spine dysfunction between men and women. Reference scores and interquartile ranges for JOABPEQ were generated based on the data from the examination data. These provide a measurement standard to assess patient perceptions of low back pain at any time point during evaluation or therapy. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Development of a PICU in Nepal: the experience of the first year.
Basnet, Sangita; Shrestha, Shrijana; Ghimire, Amrit; Timila, Dipsal; Gurung, Jeena; Karki, Utkarsha; Adhikari, Neelam; Andoh, Jennifer; Koirala, Janak
2014-09-01
Analysis of hospitalization data can help elucidate the pattern of morbidity and mortality in any given area. Little data exist on critically ill children admitted to hospitals in the resource-limited nation of Nepal. We sought to characterize the profile, management, and mortality of children admitted to one PICU. Retrospective analysis. A newly established PICU in Nepal. All patients between the ages of 0 to 16 years admitted to the PICU from July 2009 to July 2010. None. In 12 months, 126 children were admitted to the PICU including 43% female patients. Sixty-three percent were under 5 years. Twenty-nine percent came from tertiary care hospitals and 38% from rural areas outside Kathmandu. Only 18% were transported by ambulance. Median distance travelled to be admitted was 30 km (interquartile range, 10-193). Highest number of admissions were in spring (40%) followed by summer (25%). Almost half were admitted for shock (45%), particularly septic shock (30%). The second commonest reason for admission was neurologic etiologies (15%). Neonatal admissions were also significant (19%). Mortality was 26% and was significantly associated with septic shock (p < 0.01), mechanical ventilation (p < 0.01), and multiple organ dysfunction (< 0.05). Almost one third of patients required mechanical ventilation; median duration was 4 days (interquartile range, 2-8). Mean length of stay in the hospital was 6.2 days (± 5.3) and median 4 (interquartile range, 2.5-9.0). Median Pediatric Risk of Mortality II score for nonsurvivors was 12 (interquartile range, 7-21), and median Pediatric Index of Mortality II for nonsurvivors was 10 (interquartile range, 3-32). Within a short time of opening, the PICU has been seeing significant numbers of critically ill children. Despite adverse conditions and limited resources, survival of 75% is similar to many units in developing nations. Sepsis was the most common reason for PICU admission and mortality.
Redondo, Olga; Cano, Rosa; Simón, Lorena
2015-01-01
Rotavirus is a major burden on the Spanish Healthcare System. Rotarix® and RotaTeq® were simultaneously commercialized in Spain by February, 2007. The objective is to analyze the incidence and seasonality of rotavirus hospitalizations (RH) in Castile-La Mancha (CLM), following the first 3 y of commercialization. A cross-sectional study of the hospital discharge registry's Minimum Basic Data Set (MBDS) in CLM between 2003 and 2009 was performed. We used the Poisson regression model to quantify the percentage of change in the rotavirus incidence rate (IR) for 2007–09 vs. 2003–05, adjusting for age, sex, and province. To analyze changes between epidemic seasons the chi-square test was used. The median IR in 2003–09 was 224.71 per 105 [interquartile range (IQR): 185.24–274.70], which represents 60% of hospital admissions due to infectious acute gastroenteritis. The median rate in 2007–09 decreased [incidence rate ratio (IRR): 0.86, 95% CI: 0.78–0.96], significantly in Toledo (IRR: 0.54, 95% CI: 0.39–0.75). An incipient decline at the beginning of the last cold season was observed, preceded by a significant decrease of 68% in the autumn season of 2009. Despite its limited coverage, the rotavirus vaccine may have contributed to decrease RH in CLM. PMID:25644531
Aye, Myint Myint; Kilpatrick, Eric S; Aburima, Ahmed; Wraith, Katie S; Magwenzi, Simbarashe; Spurgeon, B; Rigby, Alan S; Sandeman, Derek; Naseem, Khalid M; Atkin, Stephen L
2014-02-28
Atherothrombosis is associated with platelet hyperactivity. Hypertriglyceridemia and insulin resistance (IR) are features of polycystic ovary syndrome (PCOS). The effect of induced hypertriglyceridemia on IR and platelet function was examined in young women with PCOS. Following overnight fasting, 13 PCOS and 12 healthy women were infused with saline or 20% intralipid for 5 hours on separate days. Insulin sensitivity was measured using a hyperinsulinemic euglycaemic clamp in the final 2 hours of each infusion. Platelet responses to adenosine diphosphate (ADP) and prostacyclin (PGI2) were measured by flow cytometric analysis of platelet fibrinogen binding and P-selectin expression using whole blood taken during each infusion (at 2 hours) and at the end of each clamp. Lipid infusion increased triglycerides and reduced insulin sensitivity in both controls (median, interquartile range ) (5.25 [3.3, 6.48] versus 2.60 [0.88, 3.88] mg kg(-1) min(-1), P<0.001) and PCOS (3.15 [2.94, 3.85] versus 1.06 [0.72, 1.43] mg kg(-1) min(-1), P<0.001). Platelet activation by ADP was enhanced and ability to suppress platelet activation by PGI2 diminished during lipid infusion in both groups when compared to saline. Importantly, insulin infusion decreased lipid-induced platelet hyperactivity by decreasing their response to 1 μmol/L ADP (78.7% [67.9, 82.3] versus 62.8% [51.8, 73.3], P=0.02) and increasing sensitivity to 0.01 μmol/L PGI2 (67.6% [39.5, 83.8] versus 40.9% [23.8, 60.9], P=0.01) in controls, but not in PCOS. Acute hypertriglyceridemia induced IR, and increased platelet activation in both groups that was not reversed by insulin in PCOS subjects compared to controls. This suggests that platelet hyperactivity induced by acute hypertriglyceridemia and IR could contribute athero-thrombotic risk. www.isrctn.org. Unique Identifier: ISRCTN42448814.
Aye, Myint Myint; Kilpatrick, Eric S.; Aburima, Ahmed; Wraith, Katie S.; Magwenzi, Simbarashe; Spurgeon, B.; Rigby, Alan S.; Sandeman, Derek; Naseem, Khalid M.; Atkin, Stephen L.
2014-01-01
Background Atherothrombosis is associated with platelet hyperactivity. Hypertriglyceridemia and insulin resistance (IR) are features of polycystic ovary syndrome (PCOS). The effect of induced hypertriglyceridemia on IR and platelet function was examined in young women with PCOS. Methods and Results Following overnight fasting, 13 PCOS and 12 healthy women were infused with saline or 20% intralipid for 5 hours on separate days. Insulin sensitivity was measured using a hyperinsulinemic euglycaemic clamp in the final 2 hours of each infusion. Platelet responses to adenosine diphosphate (ADP) and prostacyclin (PGI2) were measured by flow cytometric analysis of platelet fibrinogen binding and P‐selectin expression using whole blood taken during each infusion (at 2 hours) and at the end of each clamp. Lipid infusion increased triglycerides and reduced insulin sensitivity in both controls (median, interquartile range ) (5.25 [3.3, 6.48] versus 2.60 [0.88, 3.88] mg kg−1 min−1, P<0.001) and PCOS (3.15 [2.94, 3.85] versus 1.06 [0.72, 1.43] mg kg−1 min−1, P<0.001). Platelet activation by ADP was enhanced and ability to suppress platelet activation by PGI2 diminished during lipid infusion in both groups when compared to saline. Importantly, insulin infusion decreased lipid‐induced platelet hyperactivity by decreasing their response to 1 μmol/L ADP (78.7% [67.9, 82.3] versus 62.8% [51.8, 73.3], P=0.02) and increasing sensitivity to 0.01 μmol/L PGI2 (67.6% [39.5, 83.8] versus 40.9% [23.8, 60.9], P=0.01) in controls, but not in PCOS. Conclusion Acute hypertriglyceridemia induced IR, and increased platelet activation in both groups that was not reversed by insulin in PCOS subjects compared to controls. This suggests that platelet hyperactivity induced by acute hypertriglyceridemia and IR could contribute athero‐thrombotic risk. Clinical Trial Registration URL: www.isrctn.org. Unique Identifier: ISRCTN42448814. PMID:24584741
Early-Life Exposure to Perfluoroalkyl Substances and Childhood Metabolic Function
Fleisch, Abby F.; Rifas-Shiman, Sheryl L.; Mora, Ana M.; Calafat, Antonia M.; Ye, Xiaoyun; Luttmann-Gibson, Heike; Gillman, Matthew W.; Oken, Emily; Sagiv, Sharon K.
2016-01-01
Background: Perfluoroalkyl substances (PFASs) are synthetic chemicals that may persist in the environment and in humans. There is a possible association between early-life PFAS exposure and metabolic dysfunction in later life, but data are limited. Methods: We studied 665 mother–child pairs in Project Viva, a Boston, Massachusetts-area cohort recruited 1999–2002. We quantified concentrations of PFASs [perfluorooctanoate (PFOA), perfluorooctane sulfonate (PFOS), perfluorononanoate (PFNA), perfluorohexane sulfonate (PFHxS), and perfluorodecanoate (PFDeA)] in maternal plasma collected at the first prenatal visit (median, 9.6 weeks gestation) and in child plasma from the mid-childhood research visit (median, 7.7 years). We assessed leptin, adiponectin, and homeostatic model assessment of insulin resistance (HOMA-IR) in mid-childhood. We fit covariate-adjusted linear regression models and conducted stratified analyses by child sex. Results: Children with higher PFAS concentrations had lower HOMA-IR [e.g., –10.1% (95% CI: –17.3, –2.3) per interquartile range increment in PFOA]. This inverse association between child PFAS and HOMA-IR was more pronounced in females [e.g., PFOA: –15.6% (95% CI: –25.4, –4.6) vs. –6.1% (95% CI: –16.2, 5.2) for males]. Child PFAS plasma concentrations were not associated with leptin or adiponectin. Prenatal PFAS plasma concentrations were not associated with leptin, adiponectin, or HOMA-IR in offspring. Conclusions: We found no evidence for an adverse effect of early-life PFAS exposure on metabolic function in mid-childhood. In fact, children with higher PFAS concentrations had lower insulin resistance. Citation: Fleisch AF, Rifas-Shiman SL, Mora AM, Calafat AM, Ye X, Luttmann-Gibson H, Gillman MW, Oken E, Sagiv SK. 2017. Early-life exposure to perfluoroalkyl substances and childhood metabolic function. Environ Health Perspect 125:481–487; http://dx.doi.org/10.1289/EHP303 PMID:27586368
Knelson, Lauren P.; Williams, David A.; Gergen, Maria F.; Rutala, William A.; Weber, David J.; Sexton, Daniel J.; Anderson, Deverick J.
2014-01-01
A total of 1,023 environmental surfaces were sampled from 45 rooms with patients infected or colonized with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant enterococci (VRE) before terminal room cleaning. Colonized patients had higher median total target colony-forming units (CFU) of MRSA or VRE than did infected patients (median, 25 CFU [interquartile range, 0–106 CFU] vs 0 CFU [interquartile range, 0–29 CFU]; P = .033). PMID:24915217
Ekenberg, C; Lodding, I P; Wareham, N E; Sørensen, S S; Sengeløv, H; Gustafsson, F; Rasmussen, A; Perch, M; Lundgren, J D; Helleberg, M
2017-12-01
Transplant recipients are at high risk of cytomegalovirus (CMV) infection. Mechanisms explaining the variation in risk of infections are far from fully elucidated. We hypothesised that host genetics explains part of the variation in risk of infection and examined if relatives of recipients with CMV infection have higher rates of severe infections compared to relatives of recipients without this infectious phenotype. In a register-based study, we included first-degree relatives of transplant recipients and examined the risk of hospitalisation due to overall infection or viral infection and risk of death among relatives of recipients who developed CMV infection within the first year of transplantation compared to relatives of recipients without CMV. Analyses were adjusted for sex, age and calendar year. We included 4470 relatives who were followed for 103,786 person-years, median follow-up 24 years [interquartile range (IQR) 12-36]. There were a total of 1360 infection-related hospitalisations in the follow-up period, incidence rate (IR) 13.1/1000 person-years [95% confidence interval (CI), 12.4; 13.8]. 206 relatives were hospitalised with viral infection, IR 1.8/1000 person-years (95% CI, 1.6; 2.0). There was no increased risk of hospitalisation due to infections, IR ratio (IRR) 0.99 (95% CI, 0.88; 1.12), nor specifically viral infections, IRR 0.87 (95% CI, 0.63; 1.19), in relatives of recipients with CMV compared to relatives of recipients without CMV. Also, no difference was seen in analyses stratified by transplant type, family relation and CMV serostatus. The risk of hospitalisation due to infection is not increased among first-degree relatives of transplant recipients with CMV infection compared to relatives of recipients without CMV.
Peng, Song; Hu, Liang; Chen, Wenzhi; Chen, Jinyun; Yang, Caiyong; Wang, Xi; Zhang, Rong; Wang, Zhibiao; Zhang, Lian
2015-04-01
To investigate the value of microbubble contrast-enhanced ultrasound (CEUS) in evaluating the treatment response of uterine fibroids to HIFU ablation. Sixty-eight patients with a solitary uterine fibroid from the First Affiliated Hospital of Chongqing Medical University were included and analyzed. All patients underwent pre- and post-treatment magnetic resonance imaging (MRI) with a standardized protocol, as well as pre-evaluation, intraprocedure, and immediate post-treatment CEUS. CEUS and MRI were compared by different radiologists. In comparison with MRI, CEUS showed that the size of fibroids, volume of fibroids, size of non-perfused regions, non-perfused volume (NPV) or fractional ablation (NPV ratio) was similar to that of MRI. In terms of CEUS examination results, the median volume of fibroids was 75.2 (interquartile range, 34.2-127.3) cm(3), the median non-perfused volume was 54.9 (interquartile range, 28.0-98.1) cm(3), the mean fractional ablation was 83.7±13.6 (range, 30.0-100.0)%. In terms of MRI examination results, the median volume of fibroids was 74.1 (interquartile range, 33.4-116.2) cm(3). On the basis of contrast-enhanced T1-weighted images immediately after HIFU treatment, the median non-perfused volume was 58.5 (interquartile range, 27.7-100.0) cm(3), the average fractional ablation was 84.2±14.2 (range, 40.0-100.0)%. CEUS clearly showed the size of fibroids and the non-perfused areas of the fibroid. Results from CEUS correlated well with results obtained from MRI. Copyright © 2015 Elsevier B.V. All rights reserved.
Cell-Free circulating DNA: a new biomarker for the acute coronary syndrome.
Cui, Ming; Fan, Mengkang; Jing, Rongrong; Wang, Huimin; Qin, Jingfeng; Sheng, Hongzhuan; Wang, Yueguo; Wu, Xinhua; Zhang, Lurong; Zhu, Jianhua; Ju, Shaoqing
2013-01-01
In recent studies, concentrations of cell-free circulating DNA (cf-DNA) have been correlated with clinical characteristics and prognosis in several diseases. The relationship between cf-DNA concentrations and the acute coronary syndrome (ACS) remains unknown. Moreover, no data are available for the detection cf-DNA in ACS by a branched DNA (bDNA)-based Alu assay. The aim of the present study was to investigate cf-DNA concentrations in ACS and their relationship with clinical features. Plasma cf-DNA concentrations of 137 ACS patients at diagnosis, of 60 healthy individuals and of 13 patients with stable angina (SA) were determined using a bDNA-based Alu assay. ACS patients (median 2,285.0, interquartile range 916.4-4,857.3 ng/ml), especially in ST-segment elevation myocardial infarction patients (median 5,745.4, interquartile range 4,013.5-8,643.9 ng/ml), showed a significant increase in plasma cf-DNA concentrations compared with controls (healthy controls: median 118.3, interquartile range 81.1-221.1 ng/ml; SA patients: median 202.3, interquartile range 112.7-256.1 ng/ml) using a bDNA-based Alu assay. Moreover, we found positive correlations between cf-DNA and Gensini scoring and GRACE (Global Registry of Acute Coronary Events) scoring in ACS. cf-DNA may be a valuable marker for diagnosing and predicting the severity of coronary artery lesions and risk stratification in ACS. Copyright © 2013 S. Karger AG, Basel.
Spagnuolo, Vincenzo; Travi, Giovanna; Galli, Laura; Cossarini, Francesca; Guffanti, Monica; Gianotti, Nicola; Salpietro, Stefania; Lazzarin, Adriano; Castagna, Antonella
2013-08-01
The objective of this study was to compare immunologic, virologic, and clinical outcomes between living human immunodeficiency virus (HIV)-infected individuals who had a diagnosis of lymphoma versus outcomes in a control group of cancer-free, HIV-infected patients. In this matched cohort study, patients in the case group were survivors of incident lymphomas that occurred between 1997 and June 2010. Controls were living, cancer-free, HIV-infected patients who were matched to cases at a 4:1 ratio by age, sex, nadir CD4 cell count, and year of HIV diagnosis. The date of lymphoma diagnosis served as the baseline in cases and in the corresponding controls. In total, 62 patients (cases) who had lymphoma (20 with Hodgkin disease [HD] and 42 with non-Hodgkin lymphoma [NHL]) were compared with 211 controls. The overall median follow-up was 4.8 years (interquartile range, 2.0-7.9 years). The CD4 cell count at baseline was 278 cells/mm³ (interquartile range, 122-419 cells/mm³) in cases versus 421 cells/mm³ (interquartile range, 222-574 cells/mm³) in controls (P = .003). At the last available visit, the CD4 cell count was 412 cells/mm³ (range, 269-694 cells/mm³) in cases versus 518 cells/mm³ (interquartile range, 350-661 cells/mm³) in controls (P = .087). The proportion of patients who achieved virologic success increased from 30% at baseline to 74% at the last available visit in cases (P = .008) and from 51% to 81% in controls (P = .0286). Patients with HD reached higher CD4 cell counts at their last visit than patients with NHL (589 cells/mm³ [range, 400-841 cells/mm³] vs 332 cells/mm³ [interquartile range, 220-530 cells/mm³], respectively; P = .003). Virologic success was similar between patients with HD and patients with NHL at the last visit. Forty cases (65%) and 76 controls (36%) experienced at least 1 clinical event after baseline (P < .0001); cases were associated with a shorter time to occurrence of the first clinical event compared with controls (P < .0001). HIV-infected lymphoma survivors experienced more clinical events than controls, especially during the first year of follow-up, but they reached similar long-term immunologic and virologic outcomes. © 2013 American Cancer Society.
Adil, Eelam; Robson, Caroline; Perez-Atayde, Antonio; Heffernan, Colleen; Moritz, Ethan; Goumnerova, Liliana; Rahbar, Reza
2016-09-01
To describe our experience and current management approach for congenital nasal neuroglial heterotopia (NGH) and encephaloceles. Retrospective chart review at a tertiary pediatric hospital from 1970 to 2013. Thirty patients met inclusion criteria: 21 NGH and nine encephaloceles. Data including demographics, pathology, imaging modality, surgical approach, resection extent, outcomes, and complications were analyzed. Fourteen NGH patients (67%) presented with an internal nasal mass and nasal obstruction. Three patients (14%) presented with an external nasal mass and four (19%) had a mixed lesion. Median age at surgery was 0.51 years (interquartile range 1.32 years). Thirteen (62%) had an intranasal endoscopic approach. Median operative time was 1.6 hours (interquartile range 1.2 hours), and there were no major complications. Nine patients with encephalocele were identified: six (67%) presented with transethmoidal encephaloceles, two (22%) presented with nasoethmoidal encephaloceles, and one (11%) presented with a nasofrontal lesion. The median age at surgery was 1.25 years (interquartile range 1.4 years). All patients required a craniotomy for intracranial extension. Median operative time was 5 hours (interquartile range 1.9 hours), and eight patients (88%) had a total resection. Length of stay ranged from 3 to 14 days. Nasal neuroglial heterotopia and encephaloceles are very rare lesions that require multidisciplinary evaluation and management. At our institution, there has been a shift to magnetic resonance imaging alone for the evaluation of NGH to avoid radiation exposure. Endoscopic extracranial resection is feasible for most intranasal and mixed NGH without an increase in operative time, residual disease, or complications. 4. Laryngoscope, 126:2161-2167, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
A multicenter study of plasma use in the United States.
Triulzi, Darrell; Gottschall, Jerome; Murphy, Edward; Wu, Yanyun; Ness, Paul; Kor, Daryl; Roubinian, Nareg; Fleischmann, Debra; Chowdhury, Dhuly; Brambilla, Donald
2015-06-01
Detailed information regarding plasma use in the United States is needed to identify opportunities for practice improvement and design of clinical trials of plasma therapy. Ten US hospitals collected detailed medical information from the electronic health records for 1 year (2010-2011) for all adult patients transfused with plasma. A total of 72,167 units of plasma were transfused in 19,596 doses to 9269 patients. The median dose of plasma was 2 units (interquartile range, 2-4; range 1-72); 15% of doses were 1 unit, and 45% were 2 units. When adjusted by patient body weight (kg), the median dose was 7.3 mL/kg (interquartile range, 5.5-12.0). The median pretransfusion international normalized ratio (INR) was 1.9 (25%-75% interquartile range, 1.6-2.6). A total of 22.5% of plasma transfusions were given to patients with an INR of less than 1.6 and 48.5% for an INR of 2.0 or more. The median posttransfusion INR was 1.6 (interquartile range, 1.4-2.0). Only 42% of plasma transfusions resulted in a posttransfusion INR of less than 1.6. Correction of INR increased as the plasma dose increased from 1 to 4 units (p < 0.001). There was no difference in the INR response to different types of plasma. The most common issue locations were general ward (38%) and intensive care unit (ICU; 42%). This large database describing plasma utilization in the United States provides evidence for both inadequate dosing and unnecessary transfusion. Measures to improve plasma transfusion practice and clinical trials should be directed at patients on medical and surgical wards and in the ICU where plasma is most commonly used. © 2014 AABB.
A multicenter study of plasma use in the United States
Triulzi, Darrell; Gottschall, Jerome; Murphy, Edward; Wu, Yanyun; Ness, Paul; Kor, Daryl; Roubinian, Nareg; Fleischmann, Debra; Chowdhury, Dhuly; Brambilla, Donald
2016-01-01
Background Detailed information regarding plasma use in the United States is needed to identify opportunities for practice improvement and design of clinical trials of plasma therapy. Study Design and Methods Ten US hospitals collected detailed medical information from the electronic health records for 1 year (2010-2011) for all adult patients transfused with plasma. Results A total of 72,167 units of plasma were transfused in 19,596 doses to 9269 patients. The median dose of plasma was 2 units (interquartile range, 2-4; range 1-72); 15% of doses were 1 unit, and 45% were 2 units. When adjusted by patient body weight (kg), the median dose was 7.3 mL/kg (interquartile range, 5.5-12.0). The median pretransfusion international normalized ratio (INR) was 1.9 (25%-75% interquartile range, 1.6-2.6). A total of 22.5% of plasma transfusions were given to patients with an INR of less than 1.6 and 48.5% for an INR of 2.0 or more. The median posttransfusion INR was 1.6 (interquartile range, 1.4-2.0). Only 42% of plasma transfusions resulted in a posttransfusion INR of less than 1.6. Correction of INR increased as the plasma dose increased from 1 to 4 units (p < 0.001). There was no difference in the INR response to different types of plasma. The most common issue locations were general ward (38%) and intensive care unit (ICU; 42%). Conclusion This large database describing plasma utilization in the United States provides evidence for both inadequate dosing and unnecessary transfusion. Measures to improve plasma transfusion practice and clinical trials should be directed at patients on medical and surgical wards and in the ICU where plasma is most commonly used. PMID:25522888
Utilization and Outcomes of Sentinel Lymph Node Biopsy for Vulvar Cancer.
Cham, Stephanie; Chen, Ling; Burke, William M; Hou, June Y; Tergas, Ana I; Hu, Jim C; Ananth, Cande V; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D
2016-10-01
To examine the use and predictors of sentinel node biopsy in women with vulvar cancer. The Perspective database, an all-payer database that collects data from more than 500 hospitals, was used to perform a retrospective cohort study of women with vulvar cancer who underwent vulvectomy and lymph node assessment from 2006 to 2015. Multivariable models were used to determine factors associated with sentinel node biopsy. Length of stay and cost were compared between women who underwent sentinel node biopsy and lymphadenectomy. Among 2,273 women, sentinel node biopsy was utilized in 618 (27.2%) and 1,655 (72.8%) underwent inguinofemoral lymphadenectomy. Performance of sentinel node biopsy increased from 17.0% (95% confidence interval [CI] 12.0-22.0%) in 2006 to 39.1% (95% CI 27.1-51.0%) in 2015. In a multivariable model, women treated more recently were more likely to have undergone sentinel node biopsy, whereas women with more comorbidities and those treated at rural hospitals were less likely to have undergone the procedure. The median length of stay was shorter for those undergoing sentinel node biopsy (median 2 days, interquartile range 1-3) compared with women who underwent inguinofemoral lymphadenectomy (median 3 days, interquartile range 2-4). The cost of sentinel node biopsy was $7,599 (interquartile range $5,739-9,922) compared with $8,095 (interquartile range $5,917-11,281) for lymphadenectomy. The use of sentinel node biopsy for vulvar cancer has more than doubled since 2006. Sentinel lymph node biopsy is associated with a shorter hospital stay and decreased cost compared with inguinofemoral lymphadenectomy.
The New MIRUS System for Short-Term Sedation in Postsurgical ICU Patients.
Romagnoli, Stefano; Chelazzi, Cosimo; Villa, Gianluca; Zagli, Giovanni; Benvenuti, Francesco; Mancinelli, Paola; Arcangeli, Giulio; Dugheri, Stefano; Bonari, Alessandro; Tofani, Lorenzo; Belardinelli, Andrea; De Gaudio, A Raffaele
2017-09-01
To evaluate the feasibility and safety of the MIRUS system (Pall International, Sarl, Fribourg, Switzerland) for sedation with sevoflurane for postsurgical ICU patients and to evaluate atmospheric pollution during sedation. Prospective interventional study. Surgical ICU. February 2016 to December 2016. Postsurgical patients requiring ICU admission, mechanical ventilation, and sedation. Sevoflurane was administered with the MIRUS system targeted to a Richmond Agitation Sedation Scale from -3 to -5 by adaptation of minimum alveolar concentration. Data collected included Richmond Agitation Sedation Scale, minimum alveolar concentration, inspired and expired sevoflurane fraction, wake-up times, duration of sedation, sevoflurane consumption, respiratory and hemodynamic data, Simplified Acute Physiology Score II, Sepsis-related Organ Failure Assessment, and laboratory data and biomarkers of organ injury. Atmospheric pollution was monitored at different sites: before sevoflurane delivery (baseline) and during sedation with the probe 15 cm up to the MIRUS system (S1) and 15 cm from the filter-Reflector group (S2). Sixty-two patients were enrolled in the study. No technical failure occurred. Median Richmond Agitation Sedation Scale was -4.5 (interquartile range, -5 to -3.6) with sevoflurane delivered at a median minimum alveolar concentration of 0.45% (interquartile range, 0.4-0.53) yielding a mean inspiratory and expiratory concentrations of 0.79% (SD, 0.24) and 0.76% (SD, 0.18), respectively. Median awakening time was 4 minutes (2.2-5 min). Median duration of sevoflurane administration was 3.33 hours (2.33-5.75 hr), range 1-19 hours with a mean consumption of 7.89 mL/hr (SD, 2.99). Hemodynamics remained stable over the study period, and no laboratory data indicated liver or kidney injury or dysfunction. Median sevoflurane room air concentration was 0.10 parts per million (interquartile range, 0.07-0.15), 0.17 parts per million (interquartile range, 0.14-0.27), and 0.15 parts per million (interquartile range, 0.07-0.19) at baseline, S1, and S2, respectively. The MIRUS system is a promising and safe alternative for short-term sedation with sevoflurane of ICU patients. Atmospheric pollution is largely below the recommended thresholds (< 5 parts per million). Studies extended to more heterogeneous population of patients undergoing longer duration of sedation are needed to confirm these observations.
Comparison of Antivenom Dosing Strategies for Rattlesnake Envenomation.
Spyres, Meghan B; Skolnik, Aaron B; Moore, Elizabeth C; Gerkin, Richard D; Padilla-Jones, Angela; Ruha, Anne-Michelle
2018-06-01
This study compares maintenance with clinical- and laboratory-triggered (as-needed [PRN]) antivenom dosing strategies with regard to patient-centered outcomes after rattlesnake envenomation. This is a retrospective cohort study of adult rattlesnake envenomations treated at a regional toxicology center. Data on demographics, envenomation details, antivenom administration, length of stay, and laboratory and clinical outcomes were compared between the PRN and maintenance groups. Primary outcomes were hospital length of stay and total antivenom used, with a hypothesis of no difference between the two dosing strategies. A single regional toxicology center PATIENTS:: Three-hundred ten adult patients envenomated by rattlesnakes between 2007 and 2014 were included. Patients were excluded if no antivenom was administered or for receiving an antivenom other than Crofab (BTG International, West Conshohocken, PA). This is a retrospective study of rattlesnake envenomations treated with and without maintenance antivenom dosing. One-hundred forty-eight in the maintenance group and 162 in the PRN group were included. There was no difference in demographics or baseline envenomation severity or hemotoxicity (32.7% vs 40.5%; respectively; p = 0.158) between the two groups. Comparing the PRN with the maintenance group, less antivenom was used (8 [interquartile range, 6-12] vs 16 [interquartile range, 12-18] vials, respectively; p < 0.001), and hospital length of stay was shorter (27 hr [interquartile range, 20-44 hr] vs 34 hr [interquartile range, 24-43 hr], respectively; p = 0.014). There were no differences in follow-up outcomes of readmission, retreatment, or bleeding and surgical complications. Hospital length of stay was shorter, and less antivenom was used in patients receiving a PRN antivenom dosing strategy after rattlesnake envenomation.
Soon, Reni; Tschann, Mary; Salcedo, Jennifer; Stevens, Katelyn; Ahn, Hyeong Jun; Kaneshiro, Bliss
2017-08-01
To evaluate the efficacy of a paracervical block to decrease pain during osmotic dilator insertion before second-trimester abortion. In this double-blind, randomized trial, 41 women undergoing Laminaria insertion before a second-trimester abortion received either a paracervical block with 18 mL 1% lidocaine and 2 mL sodium bicarbonate or a sham block. Women were between 14 and 23 6/7 weeks of gestation. The primary outcome was pain immediately after insertion of Laminaria. Women assessed their pain on a 100-mm visual analog scale. Secondary outcomes included assessment of pain at other times during the insertion procedure and overall satisfaction with pain control. To detect a 25-mm difference in pain immediately after Laminaria insertion, at an α of 0.05 and 80% power, we aimed to enroll 20 patients in each arm. From May 2015 to December 2015, 20 women received a paracervical block and 21 received a sham block. Groups were similar in demographics, including parity, history of surgical abortion, and number of Laminaria placed. The paracervical block reduced pain after Laminaria insertion (median scores 13 mm [interquartile range 2-39] compared with 54 mm [interquartile range 27-61], P=.01, 95% CI -47.0 to -4.0). Women who received a paracervical block also reported higher satisfaction with overall pain control throughout the entire Laminaria insertion procedure (median scores 95 mm [interquartile range 78-100] compared with 70 mm [interquartile range 44-90], P=.05, 95% CI 0.0-37.0). Paracervical block is effective at reducing the pain of Laminaria insertion. Additionally, a paracervical block increases overall patient satisfaction with pain control during Laminaria placement. ClinicalTrials.gov, NCT02454296.
Nakanishi, Taizo; Goto, Tadahiro; Kobuchi, Taketsune; Kimura, Tetsuya; Hayashi, Hiroyuki; Tokuda, Yasuharu
2017-12-22
To compare bystander cardiopulmonary resuscitation skills retention between conventional learning and flipped learning for first-year medical students. A post-test only control group design. A total of 108 participants were randomly assigned to either the conventional learning or flipped learning. The primary outcome measures of time to the first chest compression and the number of total chest compressions during a 2-minute test period 6 month after the training were assessed with the Mann-Whitney U test. Fifty participants (92.6%) in the conventional learning group and 45 participants (83.3%) in the flipped learning group completed the study. There were no statistically significant differences 6 months after the training in the time to the first chest compression of 33.0 seconds (interquartile range, 24.0-42.0) for the conventional learning group and 31.0 seconds (interquartile range, 25.0-41.0) for the flipped learning group (U=1171.0, p=0.73) or in the number of total chest compressions of 101.5 (interquartile range, 90.8-124.0) for the conventional learning group and 104.0 (interquartile range, 91.0-121.0) for the flipped learning group (U=1083.0, p=0.75). The 95% confidence interval of the difference between means of the number of total chest compressions 6 months after the training did not exceed a clinically important difference defined a priori. There were no significant differences between the conventional learning group and the flipped learning group in our main outcomes. Flipped learning might be comparable to conventional learning, and seems a promising approach which requires fewer resources and enables student-centered learning without compromising the acquisition of CPR skills.
Rocha Ferreira, Graziela Santos; de Almeida, Juliano Pinheiro; Landoni, Giovanni; Vincent, Jean Louis; Fominskiy, Evgeny; Gomes Galas, Filomena Regina Barbosa; Gaiotto, Fabio A; Dallan, Luís Oliveira; Franco, Rafael Alves; Lisboa, Luiz Augusto; Palma Dallan, Luis Roberto; Fukushima, Julia Tizue; Rizk, Stephanie Itala; Park, Clarice Lee; Strabelli, Tânia Mara; Gelas Lage, Silvia Helena; Camara, Ligia; Zeferino, Suely; Jardim, Jaquelline; Calvo Arita, Elisandra Cristina Trevisan; Caldas Ribeiro, Juliana; Ayub-Ferreira, Silvia Moreira; Costa Auler, Jose Otavio; Filho, Roberto Kalil; Jatene, Fabio Biscegli; Hajjar, Ludhmila Abrahao
2018-04-30
The aim of this study was to evaluate the efficacy of perioperative intra-aortic balloon pump use in high-risk cardiac surgery patients. A single-center randomized controlled trial and a meta-analysis of randomized controlled trials. Heart Institute of São Paulo University. High-risk patients undergoing elective coronary artery bypass surgery. Patients were randomized to receive preskin incision intra-aortic balloon pump insertion after anesthesia induction versus no intra-aortic balloon pump use. The primary outcome was a composite endpoint of 30-day mortality and major morbidity (cardiogenic shock, stroke, acute renal failure, mediastinitis, prolonged mechanical ventilation, and a need for reoperation). A total of 181 patients (mean [SD] age 65.4 [9.4] yr; 32% female) were randomized. The primary outcome was observed in 43 patients (47.8%) in the intra-aortic balloon pump group and 42 patients (46.2%) in the control group (p = 0.46). The median duration of inotrope use (51 hr [interquartile range, 32-94 hr] vs 39 hr [interquartile range, 25-66 hr]; p = 0.007) and the ICU length of stay (5 d [interquartile range, 3-8 d] vs 4 d [interquartile range, 3-6 d]; p = 0.035) were longer in the intra-aortic balloon pump group than in the control group. A meta-analysis of 11 randomized controlled trials confirmed a lack of survival improvement in high-risk cardiac surgery patients with perioperative intra-aortic balloon pump use. In high-risk patients undergoing cardiac surgery, the perioperative use of an intra-aortic balloon pump did not reduce the occurrence of a composite outcome of 30-day mortality and major complications compared with usual care alone.
THE FUNDUS PHENOTYPE ASSOCIATED WITH THE p.Ala243Val BEST1 MUTATION.
Khan, Kamron N; Islam, Farrah; Moore, Anthony T; Michaelides, Michel
2018-03-01
To describe a highly recognizable and reproducible retinal phenotype associated with a specific BEST1 mutation-p.Ala243Val. Retrospective review of consecutive cases where genetic testing has identified p.Ala243Val BEST1 as the cause of disease. Electronic patient records were used to extract demographic, as well as functional and anatomical data. These data were compared with those observed with the most common BEST1 genotype, p.Arg218Cys. Eight individuals (six families) were identified with the p.Ala243Val BEST1 mutation and seven patients with the pathologic variant p.Arg218Cys. No patients with mutation of codon 243 knowingly had a family history of retinal disease, whereas all patients with the p.Arg218Cys variant did. The maculopathy was bilateral in all cases. The p.Ala243Val mutation was associated with a pattern dystrophy-type appearance, most visible with near-infrared reflectance and fundus autofluorescence imaging. This phenotype was never observed with any other genotype. This mutation was associated with an older median age of symptom onset (median = 42, interquartile range = 22) compared with those harboring the p.Arg218Cys mutation (median = 18, interquartile range = 12; Mann-Whitney U test; P < 0.05). Despite their older age, the final recorded acuity seemed to be better in the p.Ala243Val group (median = 0.55, interquartile range = 0.6475; median = 0.33, interquartile range = 0.358), although this did not reach statistical significance (Mann-Whitney U test; P > 0.05). The mutation p.Ala243Val is associated with highly recognizable and reproducible pattern dystrophy-like phenotype. Patients develop symptoms at a later age and tend to have better preservation of electrooculogram amplitudes.
Syphilis in Drug Users in Low and Middle Income Countries
Coffin, Lara S.; Newberry, Ashley; Hagan, Holly; Cleland, Charles M.; Des Jarlais, Don C.; Perlman, David C.
2009-01-01
Background Genital ulcer disease (GUD), including syphilis, is an important cause of morbidity in low and middle income (LMI) countries and syphilis transmission is associated with HIV transmission. Methods We conducted a literature review to evaluate syphilis infection among drug users in LMI countries for the period 1995–2007. Countries were categorized using the World Bank Atlas method (The World Bank, 2007) according to 2006 gross national income per capita. Results Thirty-two studies were included (N=13,848 subjects), mostly from Southeast Asia with some from Latin America, Eastern Europe, Central and East Asia, North Africa and the Middle East but none from regions such as Sub-Saharan Africa. The median prevalence of overall lifetime syphilis (N=32 studies) was 11.1% (interquartile range: 6.3% to 15.3%) and of HIV (N=31 studies) was 1.1% (interquartile range: 0.22% to 5.50%). There was a modest relation (r=0.27) between HIV and syphilis prevalence. Median syphilis prevalence by gender was 4.0% (interquartile range: 3.4% to 6.6%) among males (N=11 studies) and 19.9% (interquartile range: 11.4% to 36.0%) among females (N=6 studies). There was a strong relation (r= 0.68) between syphilis prevalence and female gender that may be related to female sex work. Conclusion Drug users in LMI countries have a high prevalence of syphilis but data are limited and, in some regions, entirely lacking. Further data are needed, including studies targeting the risks of women. Interventions to promote safer sex, testing, counseling and education, as well as health care worker awareness, should be integrated in harm reduction programs and health care settings to prevent new syphilis infections and reduce HIV transmission among drug users and their partners in LMI countries. PMID:19361976
Drummond, Peter D
2007-01-01
What is already known about this subject Repeated cycles of electrical stimulation inhibit cutaneous vasoconstriction to noradrenaline, but the mechanism is unknown. Investigating this is important because peripheral electrical stimulation is useful for pain modulation and appears to assist cutaneous wound healing. What this study adds Intermittent, brief electrical stimulation of the forearm over a 10-day period inhibited vasoconstriction and axon-reflex vasodilation to noradrenaline, but did not affect vasoconstriction to vasopressin or axon-reflex vasodilation to histamine. Thus, electrical stimulation may evoke a specific reduction in responsiveness to noradrenaline. Aim To investigate whether desensitization to the vasomotor effects of noradrenaline is a specific effect of electrical stimulation. Methods Three sites on the forearm of 10 healthy volunteers were stimulated with 0.2 mA direct current for 2 min twice daily for 10 days. Noradrenaline and histamine were then displaced from ring-shaped iontophoresis chambers into two of the pretreated sites and two untreated sites on the contralateral forearm. Axon-reflex vasodilation was measured from the centre of the ring described by the iontophoresis chamber with a laser Doppler flowmeter. One or two days later, noradrenaline and vasopressin were introduced into pretreated and untreated sites by iontophoresis, and vasoconstriction at sites of administration was measured in the heated forearm. Results The pretreatment blocked vasoconstriction to noradrenaline [median increase in flow 1%, interquartile range (IR) −41 to 52%; median decrease at the untreated site 53%, IR. −70 to −10%; P < 0.05], but did not block vasoconstriction to vasopressin (median decrease 42% at the untreated site and 45% at the pretreated site). Axon-reflex vasodilation to noradrenaline was diminished at the pretreated site (median increase in flow 33%, IR 2–321%; untreated site 247%, IR 31–1087%; P < 0.05). However, axon-reflex vasodilation to histamine did not differ significantly between the pretreated site (median increase 1085%) and the untreated site (median increase 1345%). Conclusions The conditioning pretreatment appears to evoke a specific decrease in responsiveness to noradrenaline. Repeated cycles of electrical stimulation may downregulate neural and vascular responses to noradrenaline by repetitively activating cutaneous sympathetic nerve fibres. PMID:17441931
Hansen, Lea K; Becher, Naja; Bastholm, Sara; Glavind, Julie; Ramsing, Mette; Kim, Chong J; Romero, Roberto; Jensen, Jørgen S; Uldbjerg, Niels
2014-01-01
To evaluate the microbial load and the inflammatory response in the distal and proximal parts of the cervical mucus plug. Experimental research. Twenty women with a normal, singleton pregnancy. Vaginal swabs and specimens from the distal and proximal parts of the cervical mucus plug. Immunohistochemistry, enzyme-linked immunosorbent assay, quantitative polymerase chain reaction and histology. The total bacterial load (16S rDNA) was significantly lower in the cervical mucus plug compared with the vagina (p = 0.001). Among women harboring Ureaplasma parvum, the median genome equivalents/g were 1574 (interquartile range 2526) in the proximal part, 657 (interquartile range 1620) in the distal part and 60,240 (interquartile range 96,386) in the vagina. Histological examinations and quantitative polymerase chain reaction revealed considerable amounts of lactobacilli and inflammatory cells in both parts of the cervical mucus plug. The matrix metalloproteinase-8 concentration was decreased in the proximal part of the plug compared with the distal part (p = 0.08). The cervical mucus plug inhibits, but does not block, the passage of Ureaplasma parvum during its ascending route from the vagina through the cervical canal. © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.
Adverse Drug Events and Medication Errors in African Hospitals: A Systematic Review.
Mekonnen, Alemayehu B; Alhawassi, Tariq M; McLachlan, Andrew J; Brien, Jo-Anne E
2018-03-01
Medication errors and adverse drug events are universal problems contributing to patient harm but the magnitude of these problems in Africa remains unclear. The objective of this study was to systematically investigate the literature on the extent of medication errors and adverse drug events, and the factors contributing to medication errors in African hospitals. We searched PubMed, MEDLINE, EMBASE, Web of Science and Global Health databases from inception to 31 August, 2017 and hand searched the reference lists of included studies. Original research studies of any design published in English that investigated adverse drug events and/or medication errors in any patient population in the hospital setting in Africa were included. Descriptive statistics including median and interquartile range were presented. Fifty-one studies were included; of these, 33 focused on medication errors, 15 on adverse drug events, and three studies focused on medication errors and adverse drug events. These studies were conducted in nine (of the 54) African countries. In any patient population, the median (interquartile range) percentage of patients reported to have experienced any suspected adverse drug event at hospital admission was 8.4% (4.5-20.1%), while adverse drug events causing admission were reported in 2.8% (0.7-6.4%) of patients but it was reported that a median of 43.5% (20.0-47.0%) of the adverse drug events were deemed preventable. Similarly, the median mortality rate attributed to adverse drug events was reported to be 0.1% (interquartile range 0.0-0.3%). The most commonly reported types of medication errors were prescribing errors, occurring in a median of 57.4% (interquartile range 22.8-72.8%) of all prescriptions and a median of 15.5% (interquartile range 7.5-50.6%) of the prescriptions evaluated had dosing problems. Major contributing factors for medication errors reported in these studies were individual practitioner factors (e.g. fatigue and inadequate knowledge/training) and environmental factors, such as workplace distraction and high workload. Medication errors in the African healthcare setting are relatively common, and the impact of adverse drug events is substantial but many are preventable. This review supports the design and implementation of preventative strategies targeting the most likely contributing factors.
Smerud, Hilde Kloster; Bárány, Peter; Lindström, Karin; Fernström, Anders; Sandell, Anna; Påhlsson, Peter; Fellström, Bengt
2011-10-01
Systemic corticosteroid treatment has been shown to exert some protection against renal deterioration in IgA nephropathy (IgAN) but is not commonly recommended for long-term use due to the well-known systemic side effects. In this study, we investigated the efficacy and safety of a new enteric formulation of the locally acting glucocorticoid budesonide (Nefecon®), designed to release the active compound in the ileocecal region. The primary objective was to evaluate the efficacy of targeted release budesonide on albuminuria. Budesonide 8 mg/day was given to 16 patients with IgAN for 6 months, followed by a 3-month follow-up period. The efficacy was measured as change in 24-h urine albumin excretion, serum creatinine and estimated glomerular filtration rate (eGFR). The median relative reduction in urinary albumin excretion was 23% during the treatment period (interquartile range: -0.36 to -0.04, P = 0.04) with pretreatment values ranging from 0.3 to 6 g/24 h (median: 1.5 g/24 h). The median reduction in urine albumin peaked at 40% (interquartile range: -0.58 to -0.15) 2 months after treatment discontinuation. Serum creatinine was reduced by 6% (interquartile range: -0.12 to -0.02; P = 0.003), and eGFR [Modification of Diet in Renal Disease (MDRD)] increased ∼8% (interquartile range: 0.02-0.16, P = 0.003) during treatment. No major corticosteroid-related side effects were observed. In the present pilot study, enteric budesonide targeted to the ileocecal region had a significant effect on urine albumin excretion, accompanied by a minor reduction of serum creatinine and a modest increase of eGFR calculated by the MDRD equation, while eGFR calculated from Cockcroft-Gault equation and cystatin C was not changed. Enteric budesonide may represent a new treatment of IgAN warranting further investigation.
Levels and Determinants of DDT and DDE Exposure in the VHEMBE Cohort.
Gaspar, Fraser W; Chevrier, Jonathan; Quirós-Alcalá, Lesliam; Lipsitt, Jonah M; Barr, Dana Boyd; Holland, Nina; Bornman, Riana; Eskenazi, Brenda
2017-07-07
Although indoor residual spraying (IRS) is an effective tool for malaria control, its use contributes to high insecticide exposure in sprayed communities and raises concerns about possible unintended health effects. The Venda Health Examination of Mothers, Babies and their Environment (VHEMBE) is a birth cohort study initiated in 2012 to characterize prenatal exposure to IRS insecticides and exposures' impacts on child health and development in rural South Africa. In this report, we describe the VHEMBE cohort and dichlorodiphenyltrichloroethane (DDT) and dichlorodiphenyldichloroethylene (DDE) serum concentrations measured in VHEMBE mothers when they presented for delivery. In addition, we applied a causal inference framework to estimate the potential reduction in population-level p , p' -DDT and p , p' -DDE serum concentrations under five hypothetical interventions. A total of 751 mothers were enrolled. Serum concentrations of p , p' isomers of DDT and DDE were above the limit of detection (LOD) in ≥98% of the samples, whereas the o , p' isomers were above the LOD in at least 80% of the samples. Median (interquartile range) p , p' -DDT and p , p' -DDE serum concentrations for VHEMBE cohort participants were 55.3 (19.0-259.3) and 242.2 (91.8-878.7) ng/g-lipid, respectively. Mothers reporting to have lived in a home sprayed with DDT for malaria control had ~5-7 times higher p , p' -DDT and p , p' -DDE serum concentrations than those who never lived in a home sprayed with DDT. Of the five potential interventions tested, we found increasing access to water significantly reduced p , p' -DDT exposure and increasing the frequency of household wet mopping significantly reduced p , p' -DDT and p , p' -DDE exposure. Our findings suggest that several intervention approaches may reduce DDT/DDE exposure in pregnant women living in IRS communities. https://doi.org/10.1289/EHP353.
Levels and Determinants of DDT and DDE Exposure in the VHEMBE Cohort
Gaspar, Fraser W.; Chevrier, Jonathan; Quirós-Alcalá, Lesliam; Lipsitt, Jonah M.; Barr, Dana Boyd; Holland, Nina; Bornman, Riana
2017-01-01
Background: Although indoor residual spraying (IRS) is an effective tool for malaria control, its use contributes to high insecticide exposure in sprayed communities and raises concerns about possible unintended health effects. Objective: The Venda Health Examination of Mothers, Babies and their Environment (VHEMBE) is a birth cohort study initiated in 2012 to characterize prenatal exposure to IRS insecticides and exposures’ impacts on child health and development in rural South Africa. Methods: In this report, we describe the VHEMBE cohort and dichlorodiphenyltrichloroethane (DDT) and dichlorodiphenyldichloroethylene (DDE) serum concentrations measured in VHEMBE mothers when they presented for delivery. In addition, we applied a causal inference framework to estimate the potential reduction in population-level p,p′-DDT and p,p′-DDE serum concentrations under five hypothetical interventions. A total of 751 mothers were enrolled. Results: Serum concentrations of p,p′ isomers of DDT and DDE were above the limit of detection (LOD) in ≥98% of the samples, whereas the o,p′ isomers were above the LOD in at least 80% of the samples. Median (interquartile range) p,p′-DDT and p,p′-DDE serum concentrations for VHEMBE cohort participants were 55.3 (19.0–259.3) and 242.2 (91.8–878.7) ng/g-lipid, respectively. Mothers reporting to have lived in a home sprayed with DDT for malaria control had ∼5–7 times higher p,p′-DDT and p,p′-DDE serum concentrations than those who never lived in a home sprayed with DDT. Of the five potential interventions tested, we found increasing access to water significantly reduced p,p′-DDT exposure and increasing the frequency of household wet mopping significantly reduced p,p′-DDT and p,p′-DDE exposure. Conclusion: Our findings suggest that several intervention approaches may reduce DDT/DDE exposure in pregnant women living in IRS communities. https://doi.org/10.1289/EHP353 PMID:28696207
Ferreira, Rita de Cassia dos Santos; Montenegro, Silvia Maria Lucena; Domingues, Ana Lucia Coutinho; Bandeira, Angela Pontes; Silveira, Carlos Antonio da Mota; Leite, Luiz Arthur Calheiros; Pereira, Clara de Almeida; Fernandes, Izolda Moura; Mertens, Alessandra Brainer; Almeida, Milena Oliveira
2014-05-21
It is suggested that interleukin (IL)-13 and transforming growth factor (TGF)-beta play a role in the pulmonary vascular changes found in animal models of schistosomiasis. The aim of this study was to assess and compare the serum levels of total TGF-beta and IL-13 of patients with schistosomiasis with pulmonary arterial hypertension (PAH) and patients with schistosomiasis without PAH. 34 patients from the schistosomiasis outpatient clinic of the Hospital das Clinicas, Recife, Pernambuco, Brazil, without PAH assessed by echocardiography and 34 patients from the Reference Centre of Pulmonary Hypertension of Pronto Socorro Cardiológico de Pernambuco, Recife, Brazil with PAH, confirmed by right heart catheterization, were enrolled on the study. Both groups presented with schistosomal periportal fibrosis after abdominal ultrasound. Serum levels of TGF-beta1 and IL-13 were determined by ELISA. Student t test to independent samples, Mann-Whitney test to nonparametric variables, Pearson correlation test for correlation analyses and Fisher Chi-squared test to compare categorical analyses were used. The median value of TGF-beta1 was significantly higher in patients with PAH (22496.9 pg/ml, interquartile range [IR] 15936.7 - 32087.8) than in patients without PAH (13629.9 pg/ml, IR: 10192.2- 22193.8) (p = 0.006). There was no difference in the median value of IL-13 in the group with Sch-PAH compared to patients without Sch-PAH (p > 0.05). Our results suggest that TGF-beta possibly plays a role in the pathogenesis of schistosomiasis-associated PAH.
Amigo, Hugo; Bustos, Patricia; Muzzo, Santiago; Alarcón, Ana María; Muñoz, Sergio
2010-08-01
Early onset of menarche has been linked to prevalence of obesity; however, this may differ for indigenous females. To analyse the relationship between age of menarche and nutritional status among indigenous and non-indigenous girls. The design of this study was cross-sectional. Date of menarche was determined through interviews, and all responses were confirmed by the girls' mothers. A total of 8504 adolescents were screened for recent menarche. One hundred and thirty-one girls of Mapuche (indigenous) and 143 girls of Chilean-Spanish background were identified and evaluated by anthropometric measurements. Median age of menarche was 150 months, interquartile range (IR) 143-157 in indigenous, and 145.5 months, IR 139-153 in non-indigenous girls (p = 0.04). The indigenous females showed a higher prevalence of overweight (36.4% vs 23.1%), although the frequency of obesity was similar (16.8% vs 16.3%). For indigenous girls, age of menarche was delayed by 2.69 months (confidence intervals (CI) -0.38 to 5.77). It was observed that girls with overweight experienced age of menarche 7.59 months earlier than those with normal weight, CI -10.78 to -4.41. In the analysis of obesity, the effect on age of menarche was similar, with onset 7.53 months earlier than for the normal weight, CI -11.34 to -3.72. Age of menarche is younger than has been previously reported and occurs earlier in girls with overweight and obesity, while being indigenous was not related.
Tunable optical coherence tomography in the infrared range using visible photons
NASA Astrophysics Data System (ADS)
Paterova, Anna V.; Yang, Hongzhi; An, Chengwu; Kalashnikov, Dmitry A.; Krivitsky, Leonid A.
2018-04-01
Optical coherence tomography (OCT) is an appealing technique for bio-imaging, medicine, and material analysis. For many applications, OCT in mid- and far-infrared (IR) leads to significantly more accurate results. Reported mid-IR OCT systems require light sources and photodetectors which operate in mid-IR range. These devices are expensive and need cryogenic cooling. Here, we report a proof-of-concept demonstration of a wavelength tunable IR OCT technique with detection of only visible range photons. Our method is based on the nonlinear interference of frequency correlated photon pairs. The nonlinear crystal, introduced in the Michelson-type interferometer, generates photon pairs with one photon in the visible and another in the IR range. The intensity of detected visible photons depends on the phase and loss of IR photons, which interact with the sample under study. This enables us to characterize sample properties and perform imaging in the IR range by detecting visible photons. The technique possesses broad wavelength tunability and yields a fair axial and lateral resolution, which can be tailored to the specific application. The work contributes to the development of versatile 3D imaging and material characterization systems working in a broad range of IR wavelengths, which do not require the use of IR-range light sources and photodetectors.
Jang, Sae; Vanderpool, Rebecca R; Avazmohammadi, Reza; Lapshin, Eugene; Bachman, Timothy N; Sacks, Michael; Simon, Marc A
2017-09-12
Right ventricular (RV) diastolic function has been associated with outcomes for patients with pulmonary hypertension; however, the relationship between biomechanics and hemodynamics in the right ventricle has not been studied. Rat models of RV pressure overload were obtained via pulmonary artery banding (PAB; control, n=7; PAB, n=5). At 3 weeks after banding, RV hemodynamics were measured using a conductance catheter. Biaxial mechanical properties of the RV free wall myocardium were obtained to extrapolate longitudinal and circumferential elastic modulus in low and high strain regions (E 1 and E 2 , respectively). Hemodynamic analysis revealed significantly increased end-diastolic elastance (E ed ) in PAB (control: 55.1 mm Hg/mL [interquartile range: 44.7-85.4 mm Hg/mL]; PAB: 146.6 mm Hg/mL [interquartile range: 105.8-155.0 mm Hg/mL]; P =0.010). Longitudinal E 1 was increased in PAB (control: 7.2 kPa [interquartile range: 6.7-18.1 kPa]; PAB: 34.2 kPa [interquartile range: 18.1-44.6 kPa]; P =0.018), whereas there were no significant changes in longitudinal E 2 or circumferential E 1 and E 2 . Last, wall stress was calculated from hemodynamic data by modeling the right ventricle as a sphere: stress=Pressure×radius2×thickness. RV pressure overload in PAB rats resulted in an increase in diastolic myocardial stiffness reflected both hemodynamically, by an increase in E ed , and biomechanically, by an increase in longitudinal E 1 . Modest increases in tissue biomechanical stiffness are associated with large increases in E ed . Hemodynamic measurements of RV diastolic function can be used to predict biomechanical changes in the myocardium. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Krieger, Eric V; Clair, Mathieu; Opotowsky, Alexander R; Landzberg, Michael J; Rhodes, Jonathan; Powell, Andrew J; Colan, Steven D; Valente, Anne Marie
2013-02-01
The role of exercise testing to risk stratify patients with repaired coarctation of the aorta (CoA) is controversial. Concentric left ventricular (LV) hypertrophy, defined as an increase in the LV mass-to-volume ratio (MVR), is associated with a greater incidence of adverse cardiovascular events. The objective of the present study was to determine whether a hypertensive response to exercise (HRE) is associated with increased LVMVR in patients with repaired CoA. Adults with repaired CoA who had a symptom-limited exercise test and cardiac magnetic resonance imaging examination within 2 years were identified. A hypertensive response to exercise was defined as a peak systolic blood pressure >220 mm Hg during a symptom-limited exercise test. The LV mass and volume were measured using cardiac magnetic resonance by an investigator who was unaware of patient status. We included 47 patients (median age 27.3 years, interquartile range 19.8 to 37.3), who had undergone CoA repair at a median age of 4.6 years (interquartile range 0.4 to 15.7). Those with (n = 11) and without (n = 36) HRE did not differ in age, age at repair, body surface area, arm-to-leg systolic blood pressure gradient, gender, or peak oxygen uptake with exercise. Those with a HRE had a greater mean systolic blood pressure at rest (146 ± 18 vs 137 ± 18 mm Hg, p = 0.04) and greater median LVMVR (0.85, interquartile range 0.7 to 1, vs 0.66, interquartile range 0.6 to 0.7; p = 0.04) than those without HRE. Adjusting for systolic blood pressure at rest, age, age at repair, and gender, the relation between HRE and LVMVR remained significant (p = 0.001). In conclusion, HRE was associated with increased LVMVR, even after adjusting for multiple covariates. Copyright © 2013 Elsevier Inc. All rights reserved.
Measured degree of dehydration in children and adolescents with type 1 diabetic ketoacidosis.
Ugale, Judith; Mata, Angela; Meert, Kathleen L; Sarnaik, Ashok P
2012-03-01
Successful management of diabetic ketoacidosis depends on adequate rehydration while avoiding cerebral edema. Our objectives are to 1) measure the degree of dehydration in children with type 1 diabetes mellitus and diabetic ketoacidosis based on change in body weight; and 2) investigate the relationships between measured degree of dehydration and clinically assessed degree of dehydration, severity of diabetic ketoacidosis, and routine serum laboratory values. Prospective observational study. University-affiliated tertiary care children's hospital. Sixty-six patients <18 yrs of age with type 1 diabetic ketoacidosis. Patients were weighed using a portable scale at admission; 8, 16, and 24 hrs; and daily until discharge. Measured degree of dehydration was based on the difference between admission and plateau weights. Clinical degree of dehydration was assessed by physical examination and severity of diabetic ketoacidosis was assessed by blood gas values as defined by international guidelines. Laboratory values obtained on admission included serum glucose, urea nitrogen, sodium, and osmolality. Median measured degree of dehydration was 5.2% (interquartile range, 3.1% to 7.8%). Fourteen (21%) patients were clinically assessed as mild dehydration, 49 (74%) as moderate, and three (5%) as severe. Patients clinically assessed as moderately dehydrated had a greater measured degree of dehydration (5.8%; interquartile range, 3.6% to 9.6%) than those assessed as mildly dehydrated (3.7%; interquartile range, 2.3% to 6.4%) or severely dehydrated (2.5%; interquartile range, 2.3% to 2.6%). Nine (14%) patients were assessed as mild diabetic ketoacidosis, 18 (27%) as moderate, and 39 (59%) as severe. Diabetic ketoacidosis severity groups did not differ in measured degree of dehydration. Variables independently associated with measured degree of dehydration included serum urea nitrogen and sodium concentration on admission. Hydration status in children with diabetic ketoacidosis cannot be accurately assessed by physical examination or blood gas values. Fluid therapy based on maintenance plus 6% deficit replacement is reasonable for most patients.
Mulligan, Angela A; Kuhnle, Gunter G C; Lentjes, Marleen A H; van Scheltinga, Veronica; Powell, Natasha A; McTaggart, Alison; Bhaniani, Amit; Khaw, Kay-Tee
2013-08-01
A diet rich in phyto-oestrogens has been suggested to protect against a variety of common diseases but UK intake data on phyto-oestrogens or their food sources are sparse. The present study estimates the average intakes of isoflavones, lignans, enterolignans and coumestrol from 7 d food diaries and provides data on total isoflavone, lignan and phyto-oestrogen consumption by food group. Development of a food composition database for twelve phyto-oestrogens and analysis of soya food and phyto-oestrogen consumption in a populationbased study. Men and women, aged 40–79 years, from the general population participating in the Norfolk arm of the European Prospective Investigation into Cancer and Nutrition (EPIC-Norfolk) between 1993 and 1997, with nutrient and food data from 7 d food diaries. A subset of 20 437 participants. The median daily phyto-oestrogen intake for all men was 1199 mg (interquartile range 934–1537mg; mean 1504mg, SD 1502mg) and 888mg for all women (interquartile range 710–1135 mg; mean 1205 mg, SD 1701mg). In soya consumers, median daily intakes were higher: 2861 mg in men (interquartile range 1304–7269mg; mean 5051mg, SD 5031mg) and 3142 mg in women (interquartile range 1089–7327mg; mean 5396 mg, SD 6092 mg). In both men and women, bread made the greatest contribution to phyto-oestrogen intake – 40?8% and 35?6%, respectively. In soya consumers, vegetable dishes and soya/goat’s/sheep’s milks were the main contributors – 45?7% and 21?3% in men and 38?4% and 33?7% in women, respectively. The ability to estimate phyto-oestrogen intake in Western populations more accurately will aid investigations into their suggested effects on health.
Chen, Hung-Yuan; Chiang, Chih-Kang; Wang, Hsi-Hao; Hung, Kuan-Yu; Lee, Yue-Joe; Peng, Yu-Sen; Wu, Kwan-Dun; Tsai, Tun-Jun
2008-08-01
Greater than 50% of dialysis patients experience sleep disturbances. Cognitive-behavioral therapy (CBT) is effective for treating chronic insomnia, but its effectiveness has never been reported in peritoneal dialysis (PD) patients and its association with cytokines is unknown. We investigated the effectiveness of CBT in PD patients by assessing changes in sleep quality and inflammatory cytokines. Randomized control study with parallel-group design. 24 PD patients with insomnia in a tertiary medical center without active medical and psychiatric illness were enrolled. The intervention group (N = 13) received CBT from a psychiatrist for 4 weeks and sleep hygiene education, whereas the control group (N = 11) received only sleep hygiene education. Primary outcomes were changes in the Pittsburgh Sleep Quality Index and Fatigue Severity Scale scores, and secondary outcomes were changes in serum interleukin 6 (IL-6), IL-1beta, IL-18, and tumor necrosis factor alpha levels during the 4-week trial. Median percentages of change in global Pittsburgh Sleep Quality Index scores were -14.3 (interquartile range, -35.7 to - 6.3) and -1.7 (interquartile range, -7.6 to 7.8) in the intervention and control groups, respectively (P = 0.3). Median percentages of change in global Fatigue Severity Scale scores were -12.1 (interquartile range, -59.8 to -1.5) and -10.5 (interquartile range, -14.3 to 30.4) in the intervention and control groups, respectively (P = 0.04). Serum IL-1beta level decreased in the intervention group, but increased in the control group (P = 0.04). There were no significant differences in changes in other cytokines. This study had a small number of participants and short observation period, and some participants concurrently used hypnotics. CBT may be effective for improving the quality of sleep and decreasing fatigue and inflammatory cytokine levels. CBT can be an effective nonpharmacological therapy for PD patients with sleep disturbances.
Index to Estimate the Efficiency of an Ophthalmic Practice.
Chen, Andrew; Kim, Eun Ah; Aigner, Dennis J; Afifi, Abdelmonem; Caprioli, Joseph
2015-08-01
A metric of efficiency, a function of the ratio of quality to cost per patient, will allow the health care system to better measure the impact of specific reforms and compare the effectiveness of each. To develop and evaluate an efficiency index that estimates the performance of an ophthalmologist's practice as a function of cost, number of patients receiving care, and quality of care. Retrospective review of 36 ophthalmology subspecialty practices from October 2011 to September 2012 at a university-based eye institute. The efficiency index (E) was defined as a function of adjusted number of patients (N(a)), total practice adjusted costs (C(a)), and a preliminary measure of quality (Q). Constant b limits E between 0 and 1. Constant y modifies the influence of Q on E. Relative value units and geographic cost indices determined by the Centers for Medicare and Medicaid for 2012 were used to calculate adjusted costs. The efficiency index is expressed as the following: E = b(N(a)/C(a))Q(y). Independent, masked auditors reviewed 20 random patient medical records for each practice and filled out 3 questionnaires to obtain a process-based quality measure. The adjusted number of patients, adjusted costs, quality, and efficiency index were calculated for 36 ophthalmology subspecialties. The median adjusted number of patients was 5516 (interquartile range, 3450-11,863), the median adjusted cost was 1.34 (interquartile range, 0.99-1.96), the median quality was 0.89 (interquartile range, 0.79-0.91), and the median value of the efficiency index was 0.26 (interquartile range, 0.08-0.42). The described efficiency index is a metric that provides a broad overview of performance for a variety of ophthalmology specialties as estimated by resources used and a preliminary measure of quality of care provided. The results of the efficiency index could be used in future investigations to determine its sensitivity to detect the impact of interventions on a practice such as training modules or practice restructuring.
Hartung, Julia C; Dold, Simone K; Thio, Marta; tePas, Arjan; Schmalisch, Gerd; Roehr, Charles Christoph
2014-06-01
Resuscitation guidelines give no preference over use of self-inflating bags (SIBs) or T-piece resuscitators (TPR) for manual neonatal ventilation. We speculated that devices would differ significantly regarding time required to adjust to changed ventilation settings. This was a laboratory study. Time to adjust from baseline peak inflation pressure (PIP) (20 cmH2O) to target PIP (25 and 40 cmH2O), ability to adhere to predefined ventilation settings (PIP, PEEP, and inflation rate [IR]), and the variability within and between operators were assessed for a SIB without manometer, SIB with manometer (SIBM), and two TPRs. Adjustment time was significantly longer with TPRs, compared with SIB and SIBM. The SIBM and TPRs were < 5% (median) off target PIP, and the SIB was 14% off target PIP. Significant variability between operators (interquartile range [IQR]: 71%) was seen with SIBs. PIP adjustment takes longer with TPRs, compared with SIB/SIBM. TPRs and SIBM allow satisfactory adherence to ventilation parameters. SIBs should only be used with manometer attached. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Selberherr, Andreas; Hörmann, Marcus; Prager, Gerhard; Riss, Philipp; Scheuba, Christian; Niederle, Bruno
2017-03-01
The purpose of this study was to demonstrate the high number of kidney stones in primary hyperparathyroidism (PHPT) and the low number of in fact "asymptomatic" patients. Forty patients with PHPT (28 female, 12 male; median age 58 (range 33-80) years; interquartile range 17 years [51-68]) without known symptoms of kidney stones prospectively underwent multidetector computed tomography (MDCT) and ultrasound (US) examinations of the urinary tract prior to parathyroid surgery. Images were evaluated for the presence and absence of stones, as well as for the number of stones and sizes in the long axis. The MDCT and US examinations were interpreted by two experienced radiologists who were blinded to all clinical and biochemical data. Statistical analysis was performed using the Wilcoxon signed-rank test. US revealed a total of 4 kidney stones in 4 (10 %) of 40 patients (median size 6.5 mm, interquartile range 11.5 mm). MDCT showed a total of 41 stones (median size was 3 mm, interquartile range 2.25 mm) in 15 (38 %) of 40 patients. The number of kidney stones detected with MDCT was significantly higher compared to US (p = 0.00124). MDCT is a highly sensitive method for the detection of "silent" kidney stones in patients with PHPT. By widely applying this method, the number of asymptomatic courses of PHPT may be substantially reduced. MDCT should be used primarily to detect kidney stones in PHPT and to exclude asymptomatic PHPT.
Gamma-knife radiosurgery in acromegaly: a 4-year follow-up study.
Attanasio, Roberto; Epaminonda, Paolo; Motti, Enrico; Giugni, Enrico; Ventrella, Laura; Cozzi, Renato; Farabola, Mario; Loli, Paola; Beck-Peccoz, Paolo; Arosio, Maura
2003-07-01
Stereotactic radiosurgery by gamma-knife (GK) is an attractive therapeutic option after failure of microsurgical removal in patients with pituitary adenoma. In these tumors or remnants of them, it aims to obtain the arrest of cell proliferation and hormone hypersecretion using a single precise high dose of ionizing radiation, sparing surrounding structures. The long-term efficacy and toxicity of GK in acromegaly are only partially known. Thirty acromegalic patients (14 women and 16 men) entered a prospective study of GK treatment. Most were surgical failures, whereas in 3 GK was the primary treatment. Imaging of the adenoma and target coordinates identification were obtained by high resolution magnetic resonance imaging. All patients were treated with multiple isocenters (mean, 8; range, 3-11). The 50% isodose was used in 27 patients (90%). The mean margin dose was 20 Gy (range, 15-35), and the dose to the visual pathways was always less than 8 Gy. After a median follow-up of 46 months (range, 9-96), IGF-I fell from 805 micro g/liter (median; interquartile range, 640-994) to 460 micro g/liter (interquartile range, 217-654; P = 0.0002), and normal age-matched IGF-I levels were reached in 7 patients (23%). Mean GH levels decreased from 10 micro g/liter (interquartile range, 6.4-15) to 2.9 micro g/liter (interquartile range, 2-5.3; P < 0.0001), reaching levels below 2.5 micro g/liter in 11 (37%). The rate of persistently pathological hormonal levels was still 70% at 5 yr by Kaplan-Meier analysis. The median volume was 1.43 ml (range, 0.20-3.7). Tumor shrinkage (at least 25% of basal volume) occurred after 24 months (range, 12-36) in 11 of 19 patients (58% of assessable patients). The rate of shrinkage was 79% at 4 yr. In no case was further growth observed. Only 1 patient complained of side-effects (severe headache and nausea immediately after the procedure, with full recovery in a few days with steroid therapy). Anterior pituitary failures were observed in 2 patients, who already had partial hypopituitarism, after 2 and 6 yr, respectively. No patient developed visual deficits. GK is a valid adjunctive tool in the management of acromegaly that controls GH/IGF-I hypersecretion and tumor growth, with shrinkage of adenoma and no recurrence of the disease in the considered observation period and with low acute and chronic toxicity.
Pulmonary rehabilitation in lymphangioleiomyomatosis: a controlled clinical trial.
Araujo, Mariana S; Baldi, Bruno G; Freitas, Carolina S G; Albuquerque, André L P; Marques da Silva, Cibele C B; Kairalla, Ronaldo A; Carvalho, Celso R F; Carvalho, Carlos R R
2016-05-01
Lymphangioleiomyomatosis (LAM) is a cystic lung disease frequently associated with reduced exercise capacity. The aim of this study was to assess safety and efficacy of pulmonary rehabilitation in LAM.This controlled clinical trial included 40 patients with LAM and a low physical activity level. The pulmonary rehabilitation programme comprised 24 aerobic and muscle strength training sessions and education. The primary outcome was exercise capacity (endurance time during a constant work rate exercise test). Secondary outcomes included health-related quality of life (St George's Respiratory Questionnaire (SGRQ)), 6-min walking distance (6MWD), dyspnoea, peak oxygen consumption (V'O2 ), daily physical activity (pedometer), symptoms of anxiety and depression, lung function and peripheral muscle strength (one-repetition maximum).The baseline characteristics were well balanced between the groups. The pulmonary rehabilitation group exhibited improvements in the following outcomes versus controls: endurance time (median (interquartile range) 169 (2-303) s versus -33 (-129-39) s; p=0.001), SGRQ (median (interquartile range) -8 (-16-2) versus 2 (-4-5); p=0.002) and 6MWD (median (interquartile range) 59 (13-81) m versus 20 (-12-30) m; p=0.002). Dyspnoea, peak V'O2 , daily physical activity and muscle strength also improved significantly. No serious adverse events were observed.Pulmonary rehabilitation is a safe intervention and improves exercise capacity, dyspnoea, daily physical activity, quality of life and muscle strength in LAM. Copyright ©ERS 2016.
Prehospital Emergency Care in Childhood Arterial Ischemic Stroke.
Stojanovski, Belinda; Monagle, Paul T; Mosley, Ian; Churilov, Leonid; Newall, Fiona; Hocking, Grant; Mackay, Mark T
2017-04-01
Immediately calling an ambulance is the key factor in reducing time to hospital presentation for adult stroke. Little is known about prehospital care in childhood arterial ischemic stroke (AIS). We aimed to determine emergency medical services call-taker and paramedic diagnostic sensitivity and to describe timelines of care in childhood AIS. This is a retrospective study of ambulance-transported children aged <18 years with first radiologically confirmed AIS, from 2008 to 2015. Interhospital transfers of children with preexisting AIS diagnosis were excluded. Twenty-three children were identified; 4 with unavailable ambulance records were excluded. Nineteen children were included in the study. Median age was 8 years (interquartile range, 3-14); median Pediatric National Institutes of Stroke Severity Scale score was 8 (interquartile range, 3-16). Emergency medical services call-taker diagnosis was stroke in 4 children (21%). Priority code 1 (lights and sirens) ambulances were dispatched for 13 children (68%). Paramedic diagnosis was stroke in 5 children (26%), hospital prenotification occurred in 8 children (42%), and 13 children (68%) were transported to primary stroke centers. Median prehospital timelines were onset to emergency medical services contact 13 minutes, call to scene 12 minutes, time at scene 14 minutes, transport time 43 minutes, and total prehospital time 71 minutes (interquartile range, 60-85). Emergency medical services call-taker and paramedic diagnostic sensitivity and prenotification rates are low in childhood AIS. © 2017 American Heart Association, Inc.
Location and size of flux ropes in Titan's ionosphere
NASA Astrophysics Data System (ADS)
Martin, C.; Arridge, C. S.; Badman, S. V.; Dieval, C.
2017-12-01
Cassini magnetometer data was surveyed during Titan flybys to find 73 instances of flux rope signatures. A force free flux rope model was utilised to obtain the radii, maximum magnetic field and flux content of flux ropes that adhere to the force-free assumptions. We find that flux ropes at Titan are similar in size in km and flux content to the giant flux ropes identified at Venus, with a median radii of 280 km and an inter-quartile range of 270 km, a median maximum magnetic field of 8 nT with an inter-quartile range of 7 nT and a median flux content of 76 Wb with a large inter-quartile range of 250 Wb. We additionally investigate the occurrence of flux ropes with respect to the Sun-lit facing hemisphere (zenith angle) and the ram-side of Titan within Saturn's corotating magnetosphere (angle of attack of the incoming plasma flow). We find that flux ropes are more commonly detected in Sun-lit areas of Titan's ionosphere, as well as the ram-side of Titan. We see a statistically-significant absence of flux ropes in all SLT sectors in the night side of Titan and the anti-ram side of Titan. We also comment on the physical mechanisms associated with the production of these flux ropes, with particular attention on the variability of Titan's environment in Saturn's magnetosphere.
Cheng, S; Teuffel, O; Ethier, M C; Diorio, C; Martino, J; Mayo, C; Regier, D; Wing, R; Alibhai, S M H; Sung, L
2011-01-01
Background: To describe (1) anticipated health-related quality of life during different strategies for febrile neutropaenia (FN) management and (2) attributes of those preferring inpatient management. Methods: Respondents were parents of children 0–18 years and children 12–18 years receiving cancer treatment. Anticipated health-related quality of life was elicited for four different FN management strategies: entire inpatient, early discharge, outpatient oral and outpatient intravenous (i.v.) therapy. Tools used to measure health-related quality of life were visual analogue scale (VAS), willingness to pay and time trade off. Results: A total of 155 parents and 43 children participated. For parents, median VAS scores were highest for early discharge (5.9, interquartile range 4.4–7.2) and outpatient i.v. (5.9, interquartile range 4.4–7.3). For children, median scores were highest for early discharge (6.1, interquartile range 4.6–7.2). In contrast, the most commonly preferred strategy for parents and children was inpatient in 55.0% and 37.2%, respectively. Higher current child health-related quality of life was associated with a stronger preference for outpatient management. Conclusion: Early discharge and outpatient i.v. management are associated with higher anticipated health-related quality of life, although the most commonly preferred strategy was inpatient care. This data may help with determining more cost-effective strategies for paediatric FN. PMID:21694729
Cheng, S; Teuffel, O; Ethier, M C; Diorio, C; Martino, J; Mayo, C; Regier, D; Wing, R; Alibhai, S M H; Sung, L
2011-08-23
To describe (1) anticipated health-related quality of life during different strategies for febrile neutropaenia (FN) management and (2) attributes of those preferring inpatient management. Respondents were parents of children 0-18 years and children 12-18 years receiving cancer treatment. Anticipated health-related quality of life was elicited for four different FN management strategies: entire inpatient, early discharge, outpatient oral and outpatient intravenous (i.v.) therapy. Tools used to measure health-related quality of life were visual analogue scale (VAS), willingness to pay and time trade off. A total of 155 parents and 43 children participated. For parents, median VAS scores were highest for early discharge (5.9, interquartile range 4.4-7.2) and outpatient i.v. (5.9, interquartile range 4.4-7.3). For children, median scores were highest for early discharge (6.1, interquartile range 4.6-7.2). In contrast, the most commonly preferred strategy for parents and children was inpatient in 55.0% and 37.2%, respectively. Higher current child health-related quality of life was associated with a stronger preference for outpatient management. Early discharge and outpatient i.v. management are associated with higher anticipated health-related quality of life, although the most commonly preferred strategy was inpatient care. This data may help with determining more cost-effective strategies for paediatric FN.
Lai, Agnes Y K; Ip, Mary S M; Lam, Jamie C M; Weaver, Terri E; Fong, Daniel Y T
2016-05-01
Our aim was to determine the pathway underlying the effects of continuous positive airway pressure (CPAP) adherence on intimate relationship with bed partner in men with obstructive sleep apnea (OSA). We hypothesized that CPAP with good adherence affected the intimate relationship with bed partner directly and indirectly, and it was mediated through daytime sleepiness and activity level in men with OSA. Data were obtained from an education program for enhancing CPAP adherence. Men who were newly diagnosed of OSA and CPAP therapy naïve were recruited in a tertiary teaching hospital. Self-reported quality of life [Functional Outcomes of Sleep Questionnaire], daytime sleepiness [Epworth Sleepiness Scale (ESS)], and negative emotion symptoms [depression, anxiety, stress scale] were assessed before and after CPAP treatment at 1-year assessment. Seventy-three men were included in the data analysis, with a mean ± SD age of 52 ± 10 years, body mass index of 29.0 ± 5.2 kg/m(2), ESS of 9.5 ± 5.6, and median [interquartile range(IR)] apnea and hypopnea index of 31 (21, 56) events/h. The median (IR) CPAP daily usage was 4.3(0, 6.1) h/day. From the path analysis, CPAP therapy was shown to improve intimate relationship directly (ß = 0.185) and indirectly (ß = 0.050) by reducing daytime sleepiness and increasing activity level. However, negative emotion symptoms were not the mediators between CPAP adherence and the intimate relationship. CPAP therapy with good adherence is related directly and indirectly to a better intimate relationship with bed partner in men with OSA. It was possibly attributed to reduced daytime sleepiness and increased activity level.
Tisè, Marco; Mazzarini, Laura; Fabrizzi, Giancarlo; Ferrante, Luigi; Giorgetti, Raffaele; Tagliabracci, Adriano
2011-05-01
The main importance in age estimation lies in the assessment of criminal liability and protection of unaccompanied minor immigrants, when their age is unknown. Under Italian law, persons are not criminally responsible before they reach the age of 14. The age of 18 is important when deciding whether juvenile or adult law must be applied. In the case of unaccompanied minors, it is important to assess age in order to establish special protective measures, and correct age estimation may prevent a person over 18 from benefiting from measures reserved for minors. Since the Greulich and Pyle method is one of the most frequently used in age estimation, the aim of this study was to assess the reproducibility and accuracy of the method on a large Italian sample of teenagers, to ascertain the applicability of the Atlas at the critical age thresholds of 14 and 18 years. This retrospective study examined posteroanterior X-ray projections of hand and wrist from 484 Italian-Caucasian young people (125 females, 359 males) between 11 and 19 years old. All radiographic images were taken from trauma patients hospitalized in the Azienda Ospedaliero Universitaria Ospedali Riuniti of Ancona (Italy) between 2006 and 2007. Two physicians analyzed all radiographic images separately. The blind method was used. In the case of an estimated age of 14 years old, the true age ranged from 12.2 to 15.9 years (median, 14.3 years, interquartile range, 1.0 years) for males, and 12.6 to 15.7 years (median, 14.2 years, interquartile range, 1.7 years) for females. In the case of an estimated age of 18 years, the true age ranged from 15.6 to 19.7 years (median, 17.7 years, interquartile range, 1.4 years) for males, and from 16.2 to 20.0 years (median, 18.7 years, interquartile range, 1.8 years) for females. Our study shows that although the GPM is a reproducible and repeatable method, there is a wide margin of error in the estimation of chronological age, mainly in the critical estimated ages of 14 and 18 years old in both males and females.
Vedel, Anne G; Holmgaard, Frederik; Rasmussen, Lars S; Langkilde, Annika; Paulson, Olaf B; Lange, Theis; Thomsen, Carsten; Olsen, Peter Skov; Ravn, Hanne Berg; Nilsson, Jens C
2018-04-24
Cerebral injury is an important complication after cardiac surgery with the use of cardiopulmonary bypass. The rate of overt stroke after cardiac surgery is 1% to 2%, whereas silent strokes, detected by diffusion-weighted magnetic resonance imaging, are found in up to 50% of patients. It is unclear whether a higher versus a lower blood pressure during cardiopulmonary bypass reduces cerebral infarction in these patients. In a patient- and assessor-blinded randomized trial, we allocated patients to a higher (70-80 mm Hg) or lower (40-50 mm Hg) target for mean arterial pressure by the titration of norepinephrine during cardiopulmonary bypass. Pump flow was fixed at 2.4 L·min -1 ·m -2 . The primary outcome was the total volume of new ischemic cerebral lesions (summed in millimeters cubed), expressed as the difference between diffusion-weighted imaging conducted preoperatively and again postoperatively between days 3 and 6. Secondary outcomes included diffusion-weighted imaging-evaluated total number of new ischemic lesions. Among the 197 enrolled patients, mean (SD) age was 65.0 (10.7) years in the low-target group (n=99) and 69.4 (8.9) years in the high-target group (n=98). Procedural risk scores were comparable between groups. Overall, diffusion-weighted imaging revealed new cerebral lesions in 52.8% of patients in the low-target group versus 55.7% in the high-target group ( P =0.76). The primary outcome of volume of new cerebral lesions was comparable between groups, 25 mm 3 (interquartile range, 0-118 mm 3 ; range, 0-25 261 mm 3 ) in the low-target group versus 29 mm 3 (interquartile range, 0-143 mm 3 ; range, 0-22 116 mm 3 ) in the high-target group (median difference estimate, 0; 95% confidence interval, -25 to 0.028; P =0.99), as was the secondary outcome of number of new lesions (1 [interquartile range, 0-2; range, 0-24] versus 1 [interquartile range, 0-2; range, 0-29] respectively; median difference estimate, 0; 95% confidence interval, 0-0; P =0.71). No significant difference was observed in frequency of severe adverse events. Among patients undergoing on-pump cardiac surgery, targeting a higher versus a lower mean arterial pressure during cardiopulmonary bypass did not seem to affect the volume or number of new cerebral infarcts. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02185885. © 2018 American Heart Association, Inc.
Goker, Berna; Block, Joel A
2006-01-01
The risk of developing bilateral disease progressing to total hip arthroplasty (THA) among patients who undergo unilateral THA for non-traumatic avascular necrosis (AVN) remains poorly understood. An analysis of the time-course to contralateral THA, as well as the effects of underlying AVN risk factors, is presented. Forty-seven consecutive patients who underwent THA for AVN were evaluated. Peri-operative and annual post-operative antero-posterior pelvis radiographs were examined for evidence of contralateral involvement. Patient age, weight, height, underlying AVN risk factor(s), date of onset of contralateral hip pain if occurred, and date of contralateral THA if performed, were recorded. Bone scan, computerized tomography and magnetic resonance imaging data were utilized when available. Twenty-one patients (46.6%) underwent contralateral THA for AVN within a median of 9 months after the initial THA (range 0-93, interquartile range 28.5 months). The median follow-up for patients without contralateral THA was 75 months (range 3-109, interquartile range 69 months). Thirty-four patients had radiographic findings of contralateral AVN at study entry; 25 were symptomatic bilaterally at entry and 7 developed contralateral symptoms within a mean time of 12 months (median 10 months, interquartile range 12 months). None of the 13 patients who were free of radiographic evidence of contralateral AVN at study entry developed evidence of AVN during the follow-up. AVN associated with glucocorticoid use was more likely to manifest as bilateral disease than either idiopathic AVN or ethanol-associated AVN (P=0.02 and P=0.03 respectively). Radiographically-evident AVN in the contralateral hip at THA is unlikely to remain asymptomatic for a prolonged period of time. Conversely, asymptomatic contralateral hips without radiographic evidence of AVN are unlikely to develop clinically significant AVN.
The expectation of applying IR guidance in medium range air-to-air missiles
NASA Astrophysics Data System (ADS)
Li, Lijuan; Liu, Ke
2016-10-01
IR guidance has been widely used in near range dogfight air-to-air missiles while radar guidance is dominant in medium and long range air-to-air missiles. With the development of stealth airplanes and advanced electronic countermeasures, radar missiles have met with great challenges. In this article, the advantages and potential problems of applying IR guidance in medium range air-to-air missiles are analyzed. Approaches are put forward to solve the key technologies including depressing aerodynamic heating, increasing missiles' sensitivity and acquiring target after launch. IR medium range air-to-air missiles are predicted to play important role in modern battle field.
Estimate of the influence of muzzle smoke on function range of infrared system
NASA Astrophysics Data System (ADS)
Luo, Yan-ling; Wang, Jun; Wu, Jiang-hui; Wu, Jun; Gao, Meng; Gao, Fei; Zhao, Yu-jie; Zhang, Lei
2013-09-01
Muzzle smoke produced by weapons shooting has important influence on infrared (IR) system while detecting targets. Based on the theoretical model of detecting spot targets and surface targets of IR system while there is muzzle smoke, the function range for detecting spot targets and surface targets are deduced separately according to the definition of noise equivalent temperature difference(NETD) and minimum resolution temperature difference(MRTD). Also parameters of muzzle smoke affecting function range of IR system are analyzed. Base on measured data of muzzle smoke for single shot, the function range of an IR system for detecting typical targets are calculated separately while there is muzzle smoke and there is no muzzle smoke at 8-12 micron waveband. For our IR system function range has reduced by over 10% for detecting tank if muzzle smoke exists. The results will provide evidence for evaluating the influence of muzzle smoke on IR system and will help researchers to improve ammo craftwork.
Pasupathy, Sivabaskari; Tavella, Rosanna; Grover, Suchi; Raman, Betty; Procter, Nathan E K; Du, Yang Timothy; Mahadavan, Gnanadevan; Stafford, Irene; Heresztyn, Tamila; Holmes, Andrew; Zeitz, Christopher; Arstall, Margaret; Selvanayagam, Joseph; Horowitz, John D; Beltrame, John F
2017-09-05
Contemporary ST-segment-elevation myocardial infarction management involves primary percutaneous coronary intervention, with ongoing studies focusing on infarct size reduction using ancillary therapies. N-acetylcysteine (NAC) is an antioxidant with reactive oxygen species scavenging properties that also potentiates the effects of nitroglycerin and thus represents a potentially beneficial ancillary therapy in primary percutaneous coronary intervention. The NACIAM trial (N-acetylcysteine in Acute Myocardial Infarction) examined the effects of NAC on infarct size in patients with ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention. This randomized, double-blind, placebo-controlled, multicenter study evaluated the effects of intravenous high-dose NAC (29 g over 2 days) with background low-dose nitroglycerin (7.2 mg over 2 days) on early cardiac magnetic resonance imaging-assessed infarct size. Secondary end points included cardiac magnetic resonance-determined myocardial salvage and creatine kinase kinetics. Of 112 randomized patients with ST-segment-elevation myocardial infarction, 75 (37 in NAC group, 38 in placebo group) underwent early cardiac magnetic resonance imaging. Median duration of ischemia pretreatment was 2.4 hours. With background nitroglycerin infusion administered to all patients, those randomized to NAC exhibited an absolute 5.5% reduction in cardiac magnetic resonance-assessed infarct size relative to placebo (median, 11.0%; [interquartile range 4.1, 16.3] versus 16.5%; [interquartile range 10.7, 24.2]; P =0.02). Myocardial salvage was approximately doubled in the NAC group (60%; interquartile range, 37-79) compared with placebo (27%; interquartile range, 14-42; P <0.01) and median creatine kinase areas under the curve were 22 000 and 38 000 IU·h in the NAC and placebo groups, respectively ( P =0.08). High-dose intravenous NAC administered with low-dose intravenous nitroglycerin is associated with reduced infarct size in patients with ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention. A larger study is required to assess the impact of this therapy on clinical cardiac outcomes. Australian New Zealand Clinical Trials Registry. URL: http://www.anzctr.org.au/. Unique identifier: 12610000280000. © 2017 American Heart Association, Inc.
Balaji, Seshadri; Daga, Ankana; Bradley, David J; Etheridge, Susan P; Law, Ian H; Batra, Anjan S; Sanatani, Shubayan; Singh, Anoop K; Gajewski, Kelly K; Tsao, Sabrina; Singh, Harinder R; Tisma-Dupanovic, Svjetlana; Tateno, Shigeru; Takamuro, Motoki; Nakajima, Hiromichi; Roos-Hesselink, Jolien W; Shah, Maully
2014-08-01
The study objective was to determine whether the extracardiac conduit Fontan confers an arrhythmia advantage over the intracardiac lateral tunnel Fontan. This multicenter study of 1271 patients compared bradyarrhythmia (defined as need for pacing) and tachyarrhythmia (defined as needing antiarrhythmic therapy) between 602 patients undergoing the intracardiac Fontan and 669 patients undergoing the extracardiac Fontan. The median age at the time of the Fontan procedure was 2.1 years (interquartile range, 1.6-3.2 years) for the intracardiac group and 3.0 years (interquartile range, 2.4-3.9) for the extracardiac group (P < .0001). The median follow-up was 9.2 years (interquartile range, 5-12.8) for the intracardiac group and 4.7 years (interquartile range, 2.8-7.7) for the extracardiac group (P < .0001). Early postoperative (<30 days) bradyarrhythmia occurred in 24 patients (4%) in the intracardiac group and 73 patients (11%) in the extracardiac group (P < .0001). Early postoperative (<30 days) tachyarrhythmia occurred in 32 patients (5%) in the intracardiac group and 53 patients (8%) in the extracardiac group (P = not significant). Late (>30 days) bradyarrhythmia occurred in 105 patients (18%) in the intracardiac group and 63 patients (9%) in the extracardiac group (P < .0001). Late (>30 days) tachyarrhythmia occurred in 58 patients (10%) in the intracardiac group and 23 patients (3%) in the extracardiac group (P < .0001). By multivariate analysis factoring time since surgery, more patients in the extracardiac group had early bradycardia (odds ratio, 2.9; 95% confidence interval, 1.8-4.6), with no difference in early tachycardia, late bradycardia, or late tachycardia. Overall arrhythmia burden is similar between the 2 groups, but the extracardiac Fontan group had a higher incidence of early bradyarrhythmias. There was no difference in the incidence of late tachyarrhythmias over time between the 2 operations. Therefore, the type of Fontan performed should be based on factors other than an anticipated reduction in arrhythmia burden from the extracardiac conduit. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Acute heart failure: perspectives from a randomized trial and a simultaneous registry.
Ezekowitz, Justin A; Hu, Jia; Delgado, Diego; Hernandez, Adrian F; Kaul, Padma; Leader, Rolland; Proulx, Guy; Virani, Sean; White, Michel; Zieroth, Shelley; O'Connor, Christopher; Westerhout, Cynthia M; Armstrong, Paul W
2012-11-01
Randomized controlled trials (RCT) are limited by their generalizability to the broader nontrial population. To provide a context for Acute Study of Nesiritide in Decompensated Heart Failure (ASCEND-HF) trial, we designed a complementary registry to characterize clinical characteristics, practice patterns, and in-hospital outcomes of acute heart failure patients. Eligible patients for the registry included those with a principal diagnosis of acute heart failure (ICD-9-CM 402 and 428; ICD-10 I50.x, I11.0, I13.0, I13.2) from 8 sites participating in ASCEND-HF (n=697 patients, 2007-2010). Baseline characteristics, treatments, and hospital outcomes from the registy were compared with ASCEND-HF RCT patients from 31 Canadian sites (n=465, 2007-2010). Patients in the registry were older, more likely to be female, and have chronic respiratory disease, less likely to have diabetes mellitus: they had a similar incidence of ischemic HF, atrial fibrillation, and similar B-type natriuretic peptide levels. Registry patients had higher systolic blood pressure (registry: median 132 mm Hg [interquartile range 115-151 mm Hg]; RCT: median 120 mm Hg [interquartile range 110-135 mm Hg]) and ejection fraction (registry: median 40% [interquartile range 27-58%]; RCT: median 29% [interquartile range 20-40 mm Hg]) than RCT patients. Registry patients presented more often via ambulance and had a similar total length of stay as RCT patients. In-hospital mortality was significantly higher in the registry compared with the RCT patients (9.3% versus 1.3%,P<0.001), and this remained after multivariable adjustment (odds ratio 6.6, 95% CI 2.6-16.8, P<0.001). Patients enrolled in a large RCT of acute heart failure differed significantly based on clinical characteristics, treatments, and inpatient outcomes from contemporaneous patients participating in a registry. These results highlight the need for context of RCTs to evaluate generalizability of results and especially the need to improve clinical outcomes in acute heart failure. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00475852.
Avasare, Rupali S; Canetta, Pietro A; Bomback, Andrew S; Marasa, Maddalena; Caliskan, Yasar; Ozluk, Yasemin; Li, Yifu; Gharavi, Ali G; Appel, Gerald B
2018-03-07
C3 glomerulopathy is a form of complement-mediated GN. Immunosuppressive therapy may be beneficial in the treatment of C3 glomerulopathy. Mycophenolate mofetil is an attractive treatment option given its role in the treatment of other complement-mediated diseases and the results of the Spanish Group for the Study of Glomerular Diseases C3 Study. Here, we study the outcomes of patients with C3 glomerulopathy treated with steroids and mycophenolate mofetil. We conducted a retrospective chart review of patients in the C3 glomerulopathy registry at Columbia University and identified patients treated with mycophenolate mofetil for at least 3 months and follow-up for at least 1 year. We studied clinical, histologic, and genetic data for the whole group and compared data for those who achieved complete or partial remission (responders) with those who did not achieve remission (nonresponders). We compared remission with mycophenolate mofetil with remission with other immunosuppressive regimens. We identified 30 patients who met inclusion criteria. Median age was 25 years old (interquartile range, 18-36), median creatinine was 1.07 mg/dl (interquartile range, 0.79-1.69), and median proteinuria was 3200 mg/g creatinine (interquartile range, 1720-6759). The median follow-up time was 32 months (interquartile range, 21-68). Twenty (67%) patients were classified as responders. There were no significant differences in baseline characteristics between responders and nonresponders, although initial proteinuria was lower (median 2468 mg/g creatinine) in responders compared with nonresponders (median 5000 mg/g creatinine) and soluble membrane attack complex levels were higher in responders compared with nonresponders. For those tapered off mycophenolate mofetil, relapse rate was 50%. Genome-wide analysis on complement genes was done, and in 12 patients, we found 18 variants predicted to be damaging. None of these variants were previously reported to be pathogenic. Mycophenolate mofetil with steroids outperformed other immunosuppressive regimens. Among patients who tolerated mycophenolate mofetil, combination therapy with steroids induced remission in 67% of this cohort. Heavier proteinuria at the start of therapy and lower soluble membrane attack complex levels were associated with treatment resistance. Copyright © 2018 by the American Society of Nephrology.
Mattioli, Sandro; Ruffato, Alberto; Lugaresi, Marialuisa; Pilotti, Vladimiro; Aramini, Beatrice; D'Ovidio, Frank
2010-11-01
Quality of outcome of the Heller-Dor operation is sometimes different between studies, likely because of technical reasons. We analyze the details of myotomy and fundoplication in relation to the results achieved over a 30-year single center's experience. From 1979-2008, a long esophagogastric myotomy and a partial anterior fundoplication to protect the surface of the myotomy was routinely performed with intraoperative manometry in 202 patients (97 men; median age, 55.5 years; interquartile range, 43.7-71 years) through a laparotomy and in 60 patients (24 men; median age, 46 years; interquartile range, 36.2-63 years) through a laparoscopy. The follow-up consisted of periodical interview, endoscopy, and barium swallow, and a semiquantitative scale was used to grade results. Mortality was 1 of 202 in the laparotomy group and 0 of 60 in the laparoscopy group. Median follow-up was 96 months (interquartile range, 48-190.5 months) in the laparotomy group and 48 months (interquartile range, 27-69.5 months) in the laparoscopy group. At intraoperative manometry, complete abolition of the high-pressure zone was obtained in 100%. The Dor-related high-pressure zone length and mean pressure were 4.5 ± 0.4 cm and 13.3 ± 2.2 mm Hg in the laparotomy group and 4.5 ± 0.5 cm and 13.2 ± 2.2 mm Hg in the laparoscopy group (P = .75). In the laparotomy group poor results (19/201 [9.5%]) were secondary to esophagitis in 15 (7.5%) of 201 patients (in 2 patients after 184 and 252 months, respectively) and to recurrent dysphagia in 4 (2%) of 201 patients, all with end-stage sigmoid achalasia. In the laparoscopy group 2 (3.3%) of 60 had esophagitis. A long esophagogastric myotomy protected by means of Dor fundoplication cures or substantially reduces dysphagia in the great majority of patients affected by esophageal achalasia and effectively controls postoperative esophagitis. Intraoperative manometry is likely the key factor for achieving the reported results. Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Nishisaki, Akira; Pines, Jesse M; Lin, Richard; Helfaer, Mark A; Berg, Robert A; Tenhave, Thomas; Nadkarni, Vinay M
2012-07-01
Attending physicians are only required to provide in-hospital coverage during daytime hours in many pediatric intensive care units. An in-hospital 24-hr pediatric intensive care unit attending coverage model has been increasingly popular, but the impact of 24-hr, in-hospital attending coverage on care processes and outcomes has not been reported. We compared processes of care and outcomes before and after the implementation of a 24-hr in-hospital pediatric intensive care unit attending physician model. Retrospective comparison of before and after cohorts. A single large, academic tertiary medical/surgical pediatric intensive care unit. : Pediatric intensive care unit admissions in 2000-2006. Transition to 24-hr from 12-hr in-hospital pediatric critical care attending physician coverage model in January 2004. A total of 18,702 patients were admitted to intensive care unit: 8,520 in 24 hrs; 10,182 in 12 hrs. Duration of mechanical ventilation was lower (median 33 hrs [interquartile range 12-88] vs. 48 hrs [interquartile range 16-133], adjusted reduction of 35% [95% confidence interval 25%-44%], p < .001) and intensive care unit length of stay was shorter (median 2 days [interquartile range 1-4] vs. 2 days [interquartile range 1-5], adjusted p < .001) for 24 hr vs. 12 hr coverage. The reduction in mechanical ventilation hours was similar when noninvasive, mechanical ventilation was included in ventilation hours (median 42 hrs vs. 56 hrs, adjusted reduction in ventilation hours: 33% [95% confidence interval 20-45], p < .001). Intensive care unit mortality was not significantly different (2.2% vs. 2.5%, adjusted p =.23). These associations were consistent across daytime and nighttime admissions, weekend and weekday admissions, and among subgroups with higher Pediatric Risk of Mortality III scores, postsurgical patients, and histories of previous intensive care unit admission. Implementation of 24-hr in-hospital pediatric critical care attending coverage was associated with shorter duration of mechanical ventilation and shorter length of intensive care unit stay. After accounting for potential confounders, this finding was consistent across a broad spectrum of critically ill children.
Vitamin D and parathyroid hormone status in a representative population living in Macau, China.
Ke, L; Mason, R S; Mpofu, E; Dibley, M; Li, Y; Brock, K E
2015-04-01
Associations between documented sun-exposure, exercise patterns and fish and supplement intake and 25-hydroxyvitamin D (25OHD) and parathyroid hormone (PTH) were investigated in a random household survey of Macau residents (aged 18-93). Blood samples (566) taken in summer were analyzed for 25OHD and PTH. In this Chinese population, 55% were deficient (25OHD <50nmol/L: median (interquartile range)=47.7 (24.2) nmol/L). Vitamin D deficiency was greatest in those aged <50 years: median (interquartile range)=43.3 (18.2) nmol/L, females: median (interquartile range)=45.5 (19.4) nmol/L and those with higher educational qualifications: median (interquartile range)=43.1 (18.7) nmol/L. In the total Macau population, statistically significant (p<0.01) modifiable associations with lower 25OHD levels were sunlight exposure (β=0.06), physical activity (PA) (measured as hours(hrs)/day: β=0.08), sitting (measured as hrs/day β=-0.20), intake of fish (β=0.08) and calcium (Ca) supplement intake (β=0.06) [linear regression analysis adjusting for demographic risk factors]. On similar analysis, and after adjustment for 25OHD, the only significant modifiable associations in the total population with PTH were sitting (β=-0.17), Body Mass Index (β=0.07) and Ca supplement intake (β=-0.06). In this Macau population less documented sun exposure, fish and Ca supplement intake and exercise were associated with lower 25OHD levels, especially in the younger population, along with the interesting finding that more sitting was associated with both lower 25OHD and high PTH blood levels. In conclusion, unlike findings from Caucasian populations, younger participants were significantly more vitamin D deficient, in particular highly educated single females. This may indicate the desire of young females to be pale and avoid the sun. There are also big differences in lifestyle between the older generation and the younger, in particular with respect to sun exposure and PA. This article is part of a Special Issue entitled '17th Vitamin D Workshop'. Copyright © 2015 Elsevier Ltd. All rights reserved.
Adolescent knowledge and attitudes related to clinical trials.
Brown, Devin L; Cowdery, Joan E; Jones, Toni Stokes; Langford, Aisha; Gammage, Catherine; Jacobs, Teresa L
2015-06-01
Poor enrollment plagues most clinical trials. Furthermore, despite mandates to improve minority representation in clinical trial participation, little progress has been made. We investigated the knowledge and attitudes of adolescents related to clinical trials and made race/ethnicity comparisons in an attempt to identify a possible educational intervention target. Students aged 13-18 years in southeast Michigan were offered participation through a class at one high school or two academic summer enrichment programs that drew from multiple high schools (73% response). Questionnaires previously validated in adults were administered. Non-Hispanic whites were compared with minorities using Wilcoxon rank-sum tests. Of the 82 respondents, the median age was 16 years (interquartile range: 15-17 years); 22 (28%) were white, 41 (51%) were African American, 11 (14%) were multiracial, 2 (2%) were American Indian or Alaska Native, 1 (1%) was Asian, 3 (4%) were Native Hawaiian or other Pacific Islander, and 2 respondents did not report a race (but did report Hispanic ethnicity). Nine (12%) were Hispanic. Only 27 (33%) had ever heard of a clinical trial. On a scale from 1 (most receptive) to 5 (least receptive) for learning more about a clinical trial for a relevant medical condition, the median score was 2 (interquartile range: 1-3) and for participating in a clinical trial for a relevant medical condition was 2 (interquartile range: 2-3). Overall knowledge was poor, with a median of 46% (interquartile range: 23%-62%) of knowledge answers correct. Knowledge was reduced (p = 0.0006) and attitudes were more negative (p = 0.05) in minorities than non-Hispanic whites, while minorities also endorsed more substantial barriers to trial participation (p = 0.0002). Distrust was similar between minority students and non-Hispanic whites (p = 0.15), and self-efficacy was greater in non-Hispanic whites (p = 0.05). Educational interventions directed toward adolescents that address knowledge, attitudes, and distrust in order to improve clinical trial awareness and receptivity overall are needed and may represent a tool to address disparities in minority enrollment in clinical trials. © The Author(s) 2015.
Cranston, Ross D; Baker, Jonathan R; Siegel, Aaron; Brand, Rhonda M; Janocko, Laura; McGowan, Ian
2018-03-01
Imiquimod can be used to treat internal anal high-grade squamous intraepithelial lesions. In HIV-1-infected individuals there is a theoretical concern for increased HIV replication in anorectal tissue secondary to imiquimod-induced mucosal inflammation. The purpose of this study was to assess local virologic, immunologic, and pathologic effects of imiquimod treatment in HIV-infected individuals. This was a pilot study at a single academic center. The study was conducted at the University of Pittsburgh Anal Dysplasia Clinic. HIV-1-infected individuals with biopsy-confirmed internal anal high-grade squamous intraepithelial lesions were included. Imiquimod cream was prescribed for intra-anal use 3 times per week for 9 weeks. Anal human papillomavirus typing, anal and rectal tissue HIV-1 RNA and DNA quantification, cytokine gene expression, and anal histology were measured. Nine evaluable participants (1 participant was lost to follow-up) were all white men with a median age of 46 years (interquartile range = 12 y) and a median CD4 T-cell count of 480 cells per cubic millimeter (interquartile range = 835). All were taking antiretroviral therapy, and 7 of 9 had HIV-1 RNA <50 copies per milliliter. The median dose of imiquimod used was 27.0 (interquartile range = 3.5), and there was a median of 11 days (interquartile range = 10 d) from last dose to assessment. There was no progression to cancer, no significant change in the number of human papillomavirus types detected, and no significant change in quantifiable cytokines/HIV-1 RNA or DNA levels in anal or rectal tissue. Seven (35%) of 20 high-grade lesions resolved to low-grade squamous intraepithelial lesions. The study was limited by the small number of participants and variable time to final assessment. Intra-anal imiquimod showed no evidence of immune activation or increase in HIV-1 viral replication in anal and rectal tissue and confirmed efficacy for intra-anal high-grade squamous intraepithelial lesion treatment morbidity. See Video Abstract at http://links.lww.com/DCR/A498.
Zuclich, Joseph A; Lund, David J; Stuck, Bruce E
2007-01-01
This report summarizes the results of a series of infrared (IR) laser-induced ocular damage studies conducted over the past decade. The studies examined retinal, lens, and corneal effects of laser exposures in the near-IR to far-IR transition region (wavelengths from 1.3-1.4 mum with exposure durations ranging from Q-switched to continuous wave). The corneal and retinal damage thresholds are tabulated for all pulsewidth regimes, and the wavelength dependence of the IR thresholds is discussed and contrasted to laser safety standard maximum permissible exposure limits. The analysis suggests that the current maximum permissible exposure limits could be beneficially revised to (1) relax the IR limits over wavelength ranges where unusually high safety margins may unintentionally hinder applications of recently developed military and telecommunications laser systems; (2) replace step-function discontinuities in the IR limits by continuously varying analytical functions of wavelength and pulsewidth which more closely follow the trends of the experimental retinal (for point-source laser exposures) and corneal ED50 threshold data; and (3) result in an overall simplification of the permissible exposure limits over the wavelength range from 1.2-2.6 mum. A specific proposal for amending the IR maximum permissible exposure limits over this wavelength range is presented.
Gong, Mali; Guo, Rui; He, Sifeng; Wang, Wei
2016-11-01
The security threats caused by multi-rotor unmanned aircraft vehicles (UAVs) are serious, especially in public places. To detect and control multi-rotor UAVs, knowledge of IR characteristics is necessary. The IR characteristics of a typical commercial quad-rotor UAV are investigated in this paper through thermal imaging with an IR camera. Combining the 3D geometry and IR images of the UAV, a 3D IR characteristics model is established so that the radiant power from different views can be obtained. An estimation of operating range to detect the UAV is calculated theoretically using signal-to-noise ratio as the criterion. Field experiments are implemented with an uncooled IR camera in an environment temperature of 12°C and a uniform background. For the front view, the operating range is about 150 m, which is close to the simulation result of 170 m.
Normalization methods in time series of platelet function assays
Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham
2016-01-01
Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217
Influence of Antiflatulent Dietary Advice on Intrafraction Motion for Prostate Cancer Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lips, Irene M., E-mail: I.M.Lips@umcutrecht.nl; Kotte, Alexis N.T.J.; Gils, Carla H. van
Purpose: To evaluate the effect of an antiflatulent dietary advice on the intrafraction prostate motion in patients treated with intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods and Materials: Between February 2002 and December 2009, 977 patients received five-beam IMRT for prostate cancer to a dose of 76 Gy in 35 fractions combined with fiducial markers for position verification. In July 2008, the diet, consisting of dietary guidelines to obtain regular bowel movements and to reduce intestinal gas by avoiding certain foods and air swallowing, was introduced to reduce the prostate motion. The intrafraction prostate movement was determined from the portalmore » images of the first segment of all five beams. Clinically relevant intrafraction motion was defined as {>=}50% of the fractions with an intrafraction motion outside a range of 3 mm. Results: A total of 739 patients were treated without the diet and 105 patients were treated with radiotherapy after introduction of the diet. The median and interquartile range of the average intrafraction motion per patient was 2.53 mm (interquartile range, 2.2-3.0) without the diet and 3.00 mm (interquartile range, 2.4-3.5) with the diet (p < .0001). The percentage of patients with clinically relevant intrafraction motion increased statistically significant from 19.1% without diet to 42.9% with a diet (odds ratio, 3.18; 95% confidence interval, 2.07-4.88; p < .0001). Conclusions: The results of the present study suggest that antiflatulent dietary advice for patients undergoing IMRT for prostate cancer does not reduce the intrafraction movement of the prostate. Therefore, antiflatulent dietary advice is not recommended in clinical practice for this purpose.« less
Aggarwal, Neil R; Brower, Roy G; Hager, David N; Thompson, B Taylor; Netzer, Giora; Shanholtz, Carl; Lagakos, Adrian; Checkley, William
2018-04-01
High fractions of inspired oxygen may augment lung damage to exacerbate lung injury in patients with acute respiratory distress syndrome. Participants enrolled in Acute Respiratory Distress Syndrome Network trials had a goal partial pressure of oxygen in arterial blood range of 55-80 mm Hg, yet the effect of oxygen exposure above this arterial oxygen tension range on clinical outcomes is unknown. We sought to determine if oxygen exposure that resulted in a partial pressure of oxygen in arterial blood above goal (> 80 mm Hg) was associated with worse outcomes in patients with acute respiratory distress syndrome. Longitudinal analysis of data collected in these trials. Ten clinical trials conducted at Acute Respiratory Distress Syndrome Network hospitals between 1996 and 2013. Critically ill patients with acute respiratory distress syndrome. None. We defined above goal oxygen exposure as the difference between the fraction of inspired oxygen and 0.5 whenever the fraction of inspired oxygen was above 0.5 and when the partial pressure of oxygen in arterial blood was above 80 mm Hg. We then summed above goal oxygen exposures in the first five days to calculate a cumulative above goal oxygen exposure. We determined the effect of a cumulative 5-day above goal oxygen exposure on mortality prior to discharge home at 90 days. Among 2,994 participants (mean age, 51.3 yr; 54% male) with a study-entry partial pressure of oxygen in arterial blood/fraction of inspired oxygen that met acute respiratory distress syndrome criteria, average cumulative above goal oxygen exposure was 0.24 fraction of inspired oxygen-days (interquartile range, 0-0.38). Participants with above goal oxygen exposure were more likely to die (adjusted interquartile range odds ratio, 1.20; 95% CI, 1.11-1.31) and have lower ventilator-free days (adjusted interquartile range mean difference of -0.83; 95% CI, -1.18 to -0.48) and lower hospital-free days (adjusted interquartile range mean difference of -1.38; 95% CI, -2.09 to -0.68). We observed a dose-response relationship between the cumulative above goal oxygen exposure and worsened clinical outcomes for participants with mild, moderate, or severe acute respiratory distress syndrome, suggesting that the observed relationship is not primarily influenced by severity of illness. Oxygen exposure resulting in arterial oxygen tensions above the protocol goal occurred frequently and was associated with worse clinical outcomes at all levels of acute respiratory distress syndrome severity.
Mansfield, Robert T; Lin, Kimberly Y; Zaoutis, Theoklis; Mott, Antonio R; Mohamad, Zeinab; Luan, Xianqun; Kaufman, Beth D; Ravishankar, Chitra; Gaynor, J William; Shaddy, Robert E; Rossano, Joseph W
2015-07-01
The use of ventricular assist devices has increased dramatically in adult heart failure patients. However, the overall use, outcome, comorbidities, and resource utilization of ventricular assist devices in pediatric patients have not been well described. We sought to demonstrate that the use of ventricular assist devices in pediatric patients has increased over time and that mortality has decreased. A retrospective study of the Pediatric Health Information System database was performed for patients 20 years old or younger undergoing ventricular assist device placement from 2000 to 2010. None. Four hundred seventy-five pediatric patients were implanted with ventricular assist devices during the study period: 69 in 2000-2003 (era 1), 135 in 2004-2006 (era 2), and 271 in 2007-2010 (era 3). Median age at ventricular assist device implantation was 6.0 years (interquartile range, 0.5-13.8), and the proportion of children who were 1-12 years old increased from 29% in era 1 to 47% in era 3 (p = 0.002). The majority of patients had a diagnosis of cardiomyopathy; this increased from 52% in era 1 to 72% in era 3 (p = 0.003). Comorbidities included arrhythmias (48%), pulmonary hypertension (16%), acute renal failure (34%), cerebrovascular disease (28%), and sepsis/systemic inflammatory response syndrome (34%). Two hundred forty-seven patients (52%) underwent heart transplantation and 327 (69%) survived to hospital discharge. Hospital mortality decreased from 42% in era 1 to 25% in era 3 (p = 0.004). Median hospital length of stay increased (37 d [interquartile range, 12-64 d] in era 1 vs 69 d [interquartile range, 35-130] in era 3; p < 0.001) and median adjusted hospital charges increased ($630,630 [interquartile range, $227,052-$853,318] in era 1 vs $1,577,983 [interquartile range, $874,463-$2,280,435] in era 3; p < 0.001). Factors associated with increased mortality include age less than 1 year (odds ratio, 2.04; 95% CI, 1.01-3.83), acute renal failure (odds ratio, 2.1; 95% CI, 1.26-3.65), cerebrovascular disease (odds ratio, 2.1; 95% CI, 1.25-3.62), and extracorporeal membrane oxygenation (odds ratio, 3.16; 95% CI, 1.79-5.60). Ventricular assist device placement in era 3 (odds ratio, 0.3; 95% CI, 0.15-0.57) and a diagnosis of cardiomyopathy (odds ratio, 0.5; 95% CI, 0.32-0.84), were associated with decreased mortality. Large-volume centers had lower mortality (odds ratio, 0.55; 95% CI, 0.34-0.88), lower use of extracorporeal membrane oxygenation, and higher charges. The use of ventricular assist devices and survival after ventricular assist device placement in pediatric patients have increased over time, with a concomitant increase in resource utilization. Age under 1 year, certain noncardiac morbidities, and the use of extracorporeal membrane oxygenation are associated with worse outcomes. Lower mortality was seen at larger volume ventricular assist device centers.
Gener, G; Canoui-Poitrine, F; Revuz, J E; Faye, O; Poli, F; Gabison, G; Pouget, F; Viallette, C; Wolkenstein, P; Bastuji-Garin, S
2009-01-01
Antibiotics are frequently used to treat hidradenitis suppurativa (HS); however, few data on their efficacy are available. To evaluate the efficacy of a combination of systemic clindamycin (300 mg twice daily) and rifampicin (600 mg daily) in the treatment of patients with severe HS. Patients (n = 116) who received this combination were studied retrospectively. The main outcome measure was the severity of the disease, assessed by the Sartorius score, before and after 10 weeks of treatment. The Sartorius score dramatically improved at the end of treatment (median = 29, interquartile range = 14.5, vs. median = 14.5, interquartile range = 11; p < 0.001), as did other parameters of severity as well as the quality of life score. Eight patients (6.9%) stopped the treatment because of side effects. The combination of clindamycin and rifampicin is effective in the treatment of severe HS. Copyright 2009 S. Karger AG, Basel.
Geographic variability of adherence to occupational injury treatment guidelines.
Trujillo, Antonio J; Heins, Sara E; Anderson, Gerard F; Castillo, Renan C
2014-12-01
To determine the geographic variability and relationship between six occupational injury practice guidelines. Guidelines were developed by an expert panel and evaluated using workers' compensation claims data from a large, national insurance company (1999 to 2010). Percentage compliance for each guideline was adjusted for age and sex using linear regression and mapped by hospital referral region. Regions with the lowest compliance were identified, and correlations between guidelines were calculated. Compliance to the unnecessary home care guideline showed the lowest geographic variation (interquartile range: 97.3 to 99.0), and inappropriate shoulder bracing showed the highest variation (interquartile range: 77.7 to 90.8). Correlation between the guidelines was weak and not always positive. Different guidelines showed different degrees of geographic variation. Lack of correlation between guidelines suggests that these indicators were not associated with a single underlying health care quality or patient severity construct.
ERIC Educational Resources Information Center
Turegun, Mikhail
2011-01-01
Traditional curricular materials and pedagogical strategies have not been effective in developing conceptual understanding of statistics topics and statistical reasoning abilities of students. Much of the changes proposed by statistics education research and the reform movement over the past decade have supported efforts to transform teaching…
Assessing noise sources at synchrotron infrared ports
Lerch, Ph.; Dumas, P.; Schilcher, T.; Nadji, A.; Luedeke, A.; Hubert, N.; Cassinari, L.; Boege, M.; Denard, J.-C.; Stingelin, L.; Nadolski, L.; Garvey, T.; Albert, S.; Gough, Ch.; Quack, M.; Wambach, J.; Dehler, M.; Filhol, J.-M.
2012-01-01
Today, the vast majority of electron storage rings delivering synchrotron radiation for general user operation offer a dedicated infrared port. There is growing interest expressed by various scientific communities to exploit the mid-IR emission in microspectroscopy, as well as the far infrared (also called THz) range for spectroscopy. Compared with a thermal (laboratory-based source), IR synchrotron radiation sources offer enhanced brilliance of about two to three orders of magnitude in the mid-IR energy range, and enhanced flux and brilliance in the far-IR energy range. Synchrotron radiation also has a unique combination of a broad wavelength band together with a well defined time structure. Thermal sources (globar, mercury filament) have excellent stability. Because the sampling rate of a typical IR Fourier-transform spectroscopy experiment is in the kHz range (depending on the bandwidth of the detector), instabilities of various origins present in synchrotron radiation sources play a crucial role. Noise recordings at two different IR ports located at the Swiss Light Source and SOLEIL (France), under conditions relevant to real experiments, are discussed. The lowest electron beam fluctuations detectable in IR spectra have been quantified and are shown to be much smaller than what is routinely recorded by beam-position monitors. PMID:22186638
Fassier, Thomas; Darmon, Michel; Laplace, Christian; Chevret, Sylvie; Schlemmer, Benoit; Pochard, Frédéric; Azoulay, Elie
2007-01-01
Providing family members with clear, honest, and timely information is a major task for intensive care unit physicians. Time spent informing families has been associated with effectiveness of information but has not been measured in specifically designed studies. To measure time spent informing families of intensive care unit patients. One-day cross-sectional study in 90 intensive care units in France. Clocked time spent by physicians informing the families of each of 951 patients hospitalized in the intensive care unit during a 24-hr period. Median family information time was 16 (interquartile range, 8-30) mins per patient, with 20% of the time spent explaining the diagnosis, 20% on explaining treatments, and 60% on explaining the prognosis. One third of the time was spent listening to family members. Multivariable analysis identified one factor associated with less information time (room with more than one bed) and seven factors associated with more information time, including five patient-related factors (surgery on the study day, higher Logistic Organ Dysfunction score, coma, mechanical ventilation, and worsening clinical status) and two family-related factors (first contact with family and interview with the spouse). Median information time was 20 (interquartile range, 10-39) mins when three factors were present and 106.5 (interquartile range, 103-110) mins when five were present. This study identifies factors associated with information time provided by critical care physicians to family members of critically ill patients. Whether information time correlates with communication difficulties or communication skills needs to be evaluated. Information time provided by residents and nurses should be studied.
Videogame playing as distraction technique in course of venipuncture.
Minute, M; Badina, L; Cont, G; Montico, M; Ronfani, L; Barbi, E; Ventura, A
2012-01-01
Needle-related procedures (venipuncture, intravenous cannulation) are the most common source of pain and distress for children. Reducing needle related pain and anxiety could be important in order to prevent further distress, especially for children needing multiple hospital admissions. The aim of the present open randomized controlled trial was to investigate the efficacy of adding an active distraction strategy (videogame) to EMLA premedication in needle-related pain in children. One-hundred and nine children (4 -10 years of age) were prospectively recruited to enter in the study. Ninety-seven were randomized in two groups: CC group (conventional care: EMLA only) as control group and AD group (active distraction: EMLA plus videogame) as intervention group. Outcome measures were: self-reported pain by mean of FPS-R scale (main study outcome), observer-reported pain by FLACC scale, number of attempts for successful procedure. In both groups FPS-R median rate was 0 (interquartile range: 0-2), with significant pain (FPS-R > 4) reported by 9% of subjects. FLACC median rate was 1 in both groups (interquartile range 0-3 in CC group; 0-2 in AD group). The percentage of children with major pain (FLACC > 4) was 18% in CC group and 9% in AD group (p = 0.2). The median of necessary attempts to succeed in the procedures was 1 (interquartile range 1-2) in both groups.. Active distraction doesn't improve EMLA analgesia for iv cannulation and venipuncture. Even though, it resulted in an easily applicable strategy appreciated by children. This technique could be usefully investigated in other painful procedures.
Foley, J
2008-03-01
To develop baseline data in relation to paediatric minor oral surgical procedures undertaken with both general anaesthesia and nitrous oxide inhalation sedation within a Hospital Dental Service. Data were collected prospectively over a three-year period from May 2003 to June 2006 for patients attending the Departments of Paediatric Dentistry, Dundee Dental Hospital and Ninewells Hospital, NHS Tayside, Great Britain, for all surgical procedures undertaken with either inhalation sedation or general anaesthetic. Both operator status and the procedure being undertaken were noted. In addition, the operating time was recorded. Data for 166 patients (F: 102; M: 64) with a median age of 12.50 (inter-quartile range 10.00, 14.20) years showed that 195 surgical procedures were undertaken. Of these 160 and 35 were with general anaesthetic and sedation respectively. The surgical removal of impacted, carious and supernumerary unit(s) accounted for 53.8% of all procedures, whilst the exposure of impacted teeth and soft tissue surgery represented 34.9% and 11.3% of procedures respectively. The median surgical time for techniques undertaken with sedation was 30.00 (inter-quartile range 25.00, 43.50) minutes whilst that for general anaesthetic was similar at 30.00 (inter-quartile range 15.25, 40.00) minutes (not statistically significant, (Mann Whitney U, W = 3081.5, P = 0.331). The majority of paediatric minor oral surgical procedures entail surgical exposure or removal of impacted teeth. The median treatment time for most procedures undertaken with either general anaesthetic or nitrous oxide sedation was 30 minutes.
Mehra, Tarun; Koljonen, Virve; Seifert, Burkhardt; Volbracht, Jörk; Giovanoli, Pietro; Plock, Jan; Moos, Rudolf Maria
2015-01-01
Reimbursement systems have difficulties depicting the actual cost of burn treatment, leaving care providers with a significant financial burden. Our aim was to establish a simple and accurate reimbursement model compatible with prospective payment systems. A total of 370 966 electronic medical records of patients discharged in 2012 to 2013 from Swiss university hospitals were reviewed. A total of 828 cases of burns including 109 cases of severe burns were retained. Costs, revenues and earnings for severe and nonsevere burns were analysed and a linear regression model predicting total inpatient treatment costs was established. The median total costs per case for severe burns was tenfold higher than for nonsevere burns (179 949 CHF [167 353 EUR] vs 11 312 CHF [10 520 EUR], interquartile ranges 96 782-328 618 CHF vs 4 874-27 783 CHF, p <0.001). The median of earnings per case for nonsevere burns was 588 CHF (547 EUR) (interquartile range -6 720 - 5 354 CHF) whereas severe burns incurred a large financial loss to care providers, with median earnings of -33 178 CHF (30 856 EUR) (interquartile range -95 533 - 23 662 CHF). Differences were highly significant (p <0.001). Our linear regression model predicting total costs per case with length of stay (LOS) as independent variable had an adjusted R2 of 0.67 (p <0.001 for LOS). Severe burns are systematically underfunded within the Swiss reimbursement system. Flat-rate DRG-based refunds poorly reflect the actual treatment costs. In conclusion, we suggest a reimbursement model based on a per diem rate for treatment of severe burns.
Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Pelosi, Paolo; Silva, Pedro L; de Abreu, Marcelo Gama; Rocco, Patricia R M
2017-01-01
Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV ( n = 6/group) [tidal volume (V T ) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH 2 O, fraction of inspired oxygen (FiO 2 ) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated V T values ( n = 1200; mean V T = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH 2 0/ml and 2.0 ± 0.8 cmH 2 0/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9-33.1] and VV 5.4% [3.1-8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular adhesion molecule-1 compared to NV, with no significant differences between VV and NV. Compared to VCV, VV increased the expression of surfactant protein-D, suggesting protection from type II epithelial cell damage. In conclusion, in this experimental lung ischemia-reperfusion model, VV improved respiratory system elastance and reduced lung damage compared to VCV.
Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S.; Santos, Cintia L.; Huhle, Robert; Capelozzi, Vera L.; Pelosi, Paolo; Silva, Pedro L.; de Abreu, Marcelo Gama; Rocco, Patricia R. M.
2017-01-01
Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group) [tidal volume (VT) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH2O, fraction of inspired oxygen (FiO2) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9–33.1] and VV 5.4% [3.1–8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular adhesion molecule-1 compared to NV, with no significant differences between VV and NV. Compared to VCV, VV increased the expression of surfactant protein-D, suggesting protection from type II epithelial cell damage. In conclusion, in this experimental lung ischemia-reperfusion model, VV improved respiratory system elastance and reduced lung damage compared to VCV. PMID:28512431
Nakanjako, Damalie; Kiragga, Agnes N.; Musick, Beverly S.; Yiannoutsos, Constantin T.; Wools-Kaloustian, Kara; Diero, Lameck; Oyaro, Patrick; Lugina, Emanuel; Ssali, John C.; Kambugu, Andrew; Easterbrook, Philippa
2017-01-01
Objective To describe patterns of suboptimal immune recovery (SO-IR) and associated HIV-related-illnesses during the first 5 years following first-line antiretroviral therapy (ART) initiation across seven ART sites in East Africa. Design Retrospective analysis of data from seven ART clinical sites (three Uganda, two Kenya and two Tanzania). Methods SO-IR was described by proportions of ART-treated adults with CD4+ cell counts less than 200, less than 350 and less than 500 cells/μl. Kaplan–Meier survival analysis techniques were used to assess predictors of SO-IR, and incident rates of HIV-related illnesses at CD4+ cell counts less than 200, 200–350, 351–499, and >500 cells/μl, respectively. Results Overall 80 843 adults initiated non-nucleoside reverse transcriptase inhibitor-based first-line ART; 65% were women and median CD4+ cell count was 126 [interquartile range (IQR), 52–202] cells/μl. Cumulative probability of SO-IR <200 cells/μl, <350 cells/μl and <500 cells/μl, after 5 years, was 11, 38 and 63%, respectively. Incidence of HIV-related illnesses was higher among those with CD4+ cell counts less than 200 and 200–350 cells/μl, than those who achieved CD4 counts above these thresholds. The most common events, at CD4 <200 cells/μl, were pulmonary tuberculosis [incident rate 15.98 (15.47–16.51)/100 person-years at risk (PYAR), oral candidiasis [incident rate 12.5 (12.03–12.94)] and herpes zoster [incident rate 6.30 (5.99–6.64)] events/100 PYAR. With attainment of a CD4+ cell count level 200–350 cells/μl, there was a substantial reduction in events/100 PYAR – by 91% to 1.45 (1.29–1.63) for TB, by 94% to 0.75 (0.64–0.89) for oral candidiasis, by 84% to 0.99 (0.86–1.14) for Herpes Zoster, and by 78% to 1.22 (1.07–1.39) for chronic diarrhea. The incidence of all events decreased further with CD4 counts above these thresholds. Conclusion Around 40% of adults initiated on ART have suboptimal immune recovery with CD4 counts <350 cells/ml after five years. Such patients will require closer monitoring for both HIV-related and non-HIV-related clinical events. PMID:26959510
Effort of breathing in children receiving high-flow nasal cannula.
Rubin, Sarah; Ghuman, Anoopindar; Deakers, Timothy; Khemani, Robinder; Ross, Patrick; Newth, Christopher J
2014-01-01
High-flow humidified nasal cannula is often used to provide noninvasive respiratory support in children. The effect of high-flow humidified nasal cannula on effort of breathing in children has not been objectively studied, and the mechanism by which respiratory support is provided remains unclear. This study uses an objective measure of effort of breathing (Pressure. Rate Product) to evaluate high-flow humidified nasal cannula in critically ill children. Prospective cohort study. Quaternary care free-standing academic children's hospital. ICU patients younger than 18 years receiving high-flow humidified nasal cannula or whom the medical team planned to extubate to high-flow humidified nasal cannula within 72 hours of enrollment. An esophageal pressure monitoring catheter was placed to measure pleural pressures via a Bicore CP-100 pulmonary mechanics monitor. Change in pleural pressure (ΔPes) and respiratory rate were measured on high-flow humidified nasal cannula at 2, 5, and 8 L/min. ΔPes and respiratory rate were multiplied to generate the Pressure.Rate Product, a well-established objective measure of effort of breathing. Baseline Pes, defined as pleural pressure at end exhalation during tidal breathing, reflected the positive pressure generated on each level of respiratory support. Twenty-five patients had measurements on high-flow humidified nasal cannula. Median age was 6.5 months (interquartile range, 1.3-15.5 mo). Median Pressure,Rate Product was lower on high-flow humidified nasal cannula 8 L/min (median, 329 cm H2O·min; interquartile range, 195-402) compared with high-flow humidified nasal cannula 5 L/min (median, 341; interquartile range, 232-475; p = 0.007) or high-flow humidified nasal cannula 2 L/min (median, 421; interquartile range, 233-621; p < 0.0001) and was lower on high-flow humidified nasal cannula 5 L/min compared with high-flow humidified nasal cannula 2 L/min (p = 0.01). Baseline Pes was higher on high-flow humidified nasal cannula 8 L/min than on high-flow humidified nasal cannula 2 L/min (p = 0.03). Increasing flow rates of high-flow humidified nasal cannula decreased effort of breathing in children, with the most significant impact seen from high-flow humidified nasal cannula 2 to 8 L/min. There are likely multiple mechanisms for this clinical effect, including generation of positive pressure and washout of airway dead space.
Data Analysis and Statistical Methods for the Assessment and Interpretation of Geochronologic Data
NASA Astrophysics Data System (ADS)
Reno, B. L.; Brown, M.; Piccoli, P. M.
2007-12-01
Ages are traditionally reported as a weighted mean with an uncertainty based on least squares analysis of analytical error on individual dates. This method does not take into account geological uncertainties, and cannot accommodate asymmetries in the data. In most instances, this method will understate uncertainty on a given age, which may lead to over interpretation of age data. Geologic uncertainty is difficult to quantify, but is typically greater than analytical uncertainty. These factors make traditional statistical approaches inadequate to fully evaluate geochronologic data. We propose a protocol to assess populations within multi-event datasets and to calculate age and uncertainty from each population of dates interpreted to represent a single geologic event using robust and resistant statistical methods. To assess whether populations thought to represent different events are statistically separate exploratory data analysis is undertaken using a box plot, where the range of the data is represented by a 'box' of length given by the interquartile range, divided at the median of the data, with 'whiskers' that extend to the furthest datapoint that lies within 1.5 times the interquartile range beyond the box. If the boxes representing the populations do not overlap, they are interpreted to represent statistically different sets of dates. Ages are calculated from statistically distinct populations using a robust tool such as the tanh method of Kelsey et al. (2003, CMP, 146, 326-340), which is insensitive to any assumptions about the underlying probability distribution from which the data are drawn. Therefore, this method takes into account the full range of data, and is not drastically affected by outliers. The interquartile range of each population of dates (the interquartile range) gives a first pass at expressing uncertainty, which accommodates asymmetry in the dataset; outliers have a minor affect on the uncertainty. To better quantify the uncertainty, a resistant tool that is insensitive to local misbehavior of data is preferred, such as the normalized median absolute deviations proposed by Powell et al. (2002, Chem Geol, 185, 191-204). We illustrate the method using a dataset of 152 monazite dates determined using EPMA chemical data from a single sample from the Neoproterozoic Brasília Belt, Brazil. Results are compared with ages and uncertainties calculated using traditional methods to demonstrate the differences. The dataset was manually culled into three populations representing discrete compositional domains within chemically-zoned monazite grains. The weighted mean ages and least squares uncertainties for these populations are 633±6 (2σ) Ma for a core domain, 614±5 (2σ) Ma for an intermediate domain and 595±6 (2σ) Ma for a rim domain. Probability distribution plots indicate asymmetric distributions of all populations, which cannot be accounted for with traditional statistical tools. These three domains record distinct ages outside the interquartile range for each population of dates, with the core domain lying in the subrange 642-624 Ma, the intermediate domain 617-609 Ma and the rim domain 606-589 Ma. The tanh estimator yields ages of 631±7 (2σ) for the core domain, 616±7 (2σ) for the intermediate domain and 601±8 (2σ) for the rim domain. Whereas the uncertainties derived using a resistant statistical tool are larger than those derived from traditional statistical tools, the method yields more realistic uncertainties that better address the spread in the dataset and account for asymmetry in the data.
Olivotto, Iacopo; Maron, Barry J; Appelbaum, Evan; Harrigan, Caitlin J; Salton, Carol; Gibson, C Michael; Udelson, James E; O'Donnell, Christopher; Lesser, John R; Manning, Warren J; Maron, Martin S
2010-07-15
In hypertrophic cardiomyopathy (HCM), the clinical significance attributable to the broad range of left ventricular (LV) systolic function, assessed as the ejection fraction (EF), is incompletely resolved. We evaluated the EF using cardiovascular magnetic resonance (CMR) imaging in a large cohort of patients with HCM with respect to the clinical status and evidence of left ventricular remodeling with late gadolinium enhancement (LGE). CMR imaging was performed in 310 consecutive patients, aged 42 +/- 17 years. The EF in patients with HCM was 71 +/- 10% (range 28% to 89%), exceeding that of 606 healthy controls without cardiovascular disease (66 +/- 5%, p <0.001). LGE reflecting LV remodeling showed an independent, inverse relation to the EF (B-0.69, 95% confidence interval -0.86 to -0.52; p <0.001) and was greatest in patients with an EF <50%, in whom it constituted a median value of 29% of the LV volume (interquartile range 16% to 40%). However, the substantial subgroup with low-normal EF values of 50% to 65% (n = 45; 15% of the whole cohort), who were mostly asymptomatic or mildly symptomatic (37 or 82% with New York Heart Association functional class I to II), showed substantial LGE (median 5% of LV volume, interquartile range 2% to 10%). This overlapped with the subgroup with systolic dysfunction and significantly exceeded that of patients with an EF of 66% to 75% and >75% (median 2% of the LV volume, interquartile range 1.5% to 4%; p <0.01). In conclusion, in a large cohort of patients with HCM, a subset of patients with low-normal EF values (50% to 65%) was identified by contrast-enhanced CMR imaging as having substantial degrees of LGE, suggesting a transition phase, potentially heralding advanced LV remodeling and systolic dysfunction, with implications for clinical surveillance and management. Copyright (c) 2010. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finnegan, D.L.; Miller, T.L.; Zoller, W.H.
Particle and gas samples were collected at Mauna Loa volcano during and after its eruption in March and April, 1984 and at Kilauea volcano in 1983, 1984, and 1985 during various phases of its ongoing activity. In the last two Kilauea sampling missions, samples were collected during eruptive activity. The samples were analyzed by INAA for over 40 elements. We have found Ir in samples collected at Kilauea and Mauna Loa during fountaining activity as well as after eruptive activity. Os was also seen in the Mauna Loa samples. Enrichment factors for Ir in the volcanic fumes range from 10/supmore » 4/ to 10/sup 5/ relative to BHVO. Flux calculations for Ir at Mauna Loa and Kilauea had ranges of 80 to 3000 and 10 to 315 g/d respectively. The percentage of Ir released from the magma into the fumes ranged from 1% to 12% for both volcanoes. Calculations assuming the Deccan as the source of Ir for the K/T boundary layer show that the concentration of Ir left in the basalts may be too low to account for all of the K/T Ir. It would require a very high fraction (> 30%) of the Ir to be purged from the basalt to account for all the Ir, which cannot be supported by the Hawaiian data. 26 refs., 1 fig., 4 tabs.« less
Far-IR transparency and dynamic infrared signature control with novel conducting polymer systems
NASA Astrophysics Data System (ADS)
Chandrasekhar, Prasanna; Dooley, T. J.
1995-09-01
Materials which possess transparency, coupled with active controllability of this transparency in the infrared (IR), are today an increasingly important requirement, for varied applications. These applications include windows for IR sensors, IR-region flat panel displays used in camouflage as well as in communication and sight through night-vision goggles, coatings with dynamically controllable IR-emissivity, and thermal conservation coatings. Among stringent requirements for these applications are large dynamic ranges (color contrast), 'multi-color' or broad-band characteristics, extended cyclability, long memory retention, matrix addressability, small area fabricability, low power consumption, and environmental stability. Among materials possessing the requirements for variation of IR signature, conducting polymers (CPs) appear to be the only materials with dynamic, actively controllable signature and acceptable dynamic range. Conventional CPs such as poly(alkyl thiophene), poly(pyrrole) or poly(aniline) show very limited dynamic range, especially in the far-IR, while also showing poor transparency. We have developed a number of novel CP systems ('system' implying the CP, the selected dopant, the synthesis method, and the electrolyte) with very wide dynamic range (up to 90% in both important IR regions, 3 - 5 (mu) and 8 - 12 (mu) ), high cyclability (to 105 cycles with less than 10% optical degradation), nearly indefinite optical memory retention, matrix addressability of multi-pixel displays, very wide operating temperature and excellent environmental stability, low charge capacity, and processability into areas from less than 1 mm2 to more than 100 cm2. The criteria used to design and arrive at these CP systems, together with representative IR signature data, are presented in this paper.
A systematic review of population based epidemiological studies in Myasthenia Gravis
2010-01-01
Background The aim was to collate all myasthenia gravis (MG) epidemiological studies including AChR MG and MuSK MG specific studies. To synthesize data on incidence rate (IR), prevalence rate (PR) and mortality rate (MR) of the condition and investigate the influence of environmental and technical factors on any trends or variation observed. Methods Studies were identified using multiple sources and meta-analysis performed to calculate pooled estimates for IR, PR and MR. Results 55 studies performed between 1950 and 2007 were included, representing 1.7 billion population-years. For All MG estimated pooled IR (eIR): 5.3 per million person-years (C.I.:4.4, 6.1), range: 1.7 to 21.3; estimated pooled PR: 77.7 per million persons (C.I.:64.0, 94.3), range 15 to 179; MR range 0.1 to 0.9 per millions person-years. AChR MG eIR: 7.3 (C.I.:5.5, 7.8), range: 4.3 to 18.0; MuSK MG IR range: 0.1 to 0.32. However marked variation persisted between populations studied with similar methodology and in similar areas. Conclusions We report marked variation in observed frequencies of MG. We show evidence of increasing frequency of MG with year of study and improved study quality. This probably reflects improved case ascertainment. But other factors must also influence disease onset resulting in the observed variation in IR across geographically and genetically similar populations. PMID:20565885
Shanley, Ellen; Rauh, Mitchell J; Michener, Lori A; Ellenbecker, Todd S; Garrison, J Craig; Thigpen, Charles A
2011-09-01
Range of motion deficits in shoulder external rotation (ER), internal rotation (IR), total rotation range of motion (ER + IR), and horizontal adduction (HA) have been retrospectively associated with overhand athletes' arm injuries. The authors expected the incidence of upper extremity injury in high school softball and baseball players with side-to-side shoulder range of motion deficits to be greater than the incidence of upper extremity injury in players with normal shoulder range of motion. Cohort study (prognosis); Level of evidence, 2. High school softball and baseball players (N = 246) participated. Before the start of the season, passive shoulder ER, IR, and HA were assessed at 90° of abduction with the scapula stabilized. Relative risk (RR) was calculated to examine range of motion measure, by categorical criteria, and risk of upper extremity injury. Twenty-seven shoulder and elbow injuries (9 softball, 18 baseball) were observed during the season. The dominant shoulder of all injured players and baseball players displayed a significant decrease in HA (P = .05) and IR (P = .04). The dominant shoulder total rotation of injured baseball players displayed a significant decrease (mean difference = 8.0° ± 0.1°; P = .05) as compared with the dominant shoulder of uninjured baseball players. Players who displayed a decrease of ≥25° of IR in the dominant shoulder were at 4 times greater risk of upper extremity injury compared with players with a <25° decrease in IR, especially for baseball players. While we observed a 1.5 to 2 times increased risk of injury for the 10° to 20° loss in rotational range of motion for the overall sample and baseball, the risk estimates were not statistically significant (P > .05). There are large mean deficits in shoulder IR and HA between injured and noninjured players, but not in ER or total rotation. Passive shoulder IR loss ≥25° as compared bilaterally was predictive of arm injury. Shoulder range of motion deficits differed between sports and appeared more predictive of injury for baseball players.
Simonis, Fabienne D; de Iudicibus, Gianfranco; Cremer, Olaf L; Ong, David S Y; van der Poll, Tom; Bos, Lieuwe D; Schultz, Marcus J
2018-01-01
Macrolides have been associated with favorable immunological effects in various inflammatory disease states. We investigated the association between macrolide therapy and mortality in patients with the acute respiratory distress syndrome (ARDS). This was an unplanned secondary analysis of patients with ARDS within a large prospective observational study of critically ill patients in the intensive care units (ICUs) of two university-affiliated hospitals in the Netherlands. The exposure of interest was low-dose macrolide use prescribed for another reason than infection; we excluded patients who received high-dose macrolides for an infection. The primary endpoint was 30-day mortality. The association between macrolide therapy and mortality was determined in the whole cohort, as well as in a propensity score matched cohort; the association was compared between pulmonary versus non-pulmonary ARDS, and between two biological phenotypes based on plasma levels of 20 biomarkers. In total, 873 patients with ARDS were analyzed, of whom 158 patients (18%) received macrolide therapy during stay in ICU for a median duration of 3 (interquartile range, 1-4) days. Erythromycin was the most frequent prescribed macrolide (97%). Macrolide therapy was associated with reduced 30-day mortality in the whole cohort [22.8% vs. 31.6%; crude odds ratio (OR), 0.64 (interquartile range, 0.43-0.96), P=0.03]. The association in the propensity score matched cohort remained significant [22.8% vs. 32.9%; OR, 0.62 (interquartile range, 0.39-0.96), P=0.03]. Propensity matched associations with mortality were different in patients with non-pulmonary ARDS vs. pulmonary ARDS and also varied by biological phenotype. These data together show that low-dose macrolide therapy prescribed for another reason than infection is associated with decreased mortality in patients with ARDS.
Scientific Production of Research Fellows at the Zagreb University School of Medicine, Croatia
Polašek, Ozren; Kolčić, Ivana; Buneta, Zoran; Čikeš, Nada; Pećina, Marko
2006-01-01
Aim To evaluate scientific production among research fellows employed at the Zagreb University School of Medicine and identify factors associated with their scientific output. Method We conducted a survey among research fellows and their mentors during June 2005. The main outcome measure was publication success, defined for each fellow as publishing at least 0.5 articles per employment year in journals indexed in the Current Contents bibliographic database. Bivariate methods and binary logistic regression were used in data analysis. Results A total of 117 fellows (response rate 95%) and 83 mentors (100%) were surveyed. The highest scientific production was recorded among research fellows employed in public health departments (median 3.0 articles, interquartile range 4.0), compared with those from pre-clinical (median 0.0, interquartile range 2.0) and clinical departments (median 1.0, interquartile range 2.0) (Kruskal-Wallis, P = 0.003). A total of 36 (29%) research fellows published at least 0.5 articles per employment year and were considered successful. Three variables were associated with fellows’ publication success: mentor’s scientific production (odds ratio [OR], 3.14; 95% confidence interval [CI], 1.31-7.53), positive mentor’s assessment (OR, 3.15; 95% CI, 1.10-9.05), and fellows’ undergraduate publication in journals indexed in the Current Contents bibliographic database (OR, 4.05; 95% CI, 1.07-15.34). Conclusion Undergraduate publication could be used as one of the main criteria in selecting research fellows. One of the crucial factors in a fellow’s scientific production and career advancement is mentor’s input, which is why research fellows would benefit most from working with scientifically productive mentors. PMID:17042070
Prabhu, Malavika; Clapp, Mark A; McQuaid-Hanson, Emily; Ona, Samsiya; OʼDonnell, Taylor; James, Kaitlyn; Bateman, Brian T; Wylie, Blair J; Barth, William H
2018-07-01
To evaluate whether a liposomal bupivacaine incisional block decreases postoperative pain and represents an opioid-minimizing strategy after scheduled cesarean delivery. In a single-blind, randomized controlled trial among opioid-naive women undergoing cesarean delivery, liposomal bupivacaine or placebo was infiltrated into the fascia and skin at the surgical site, before fascial closure. Using an 11-point numeric rating scale, the primary outcome was pain score with movement at 48 hours postoperatively. A sample size of 40 women per group was needed to detect a 1.5-point reduction in pain score in the intervention group. Pain scores and opioid consumption, in oral morphine milligram equivalents, at 48 hours postoperatively were summarized as medians (interquartile range) and compared using the Wilcoxon rank-sum test. Between March and September 2017, 249 women were screened, 103 women enrolled, and 80 women were randomized. One woman in the liposomal bupivacaine group was excluded after randomization as a result of a vertical skin incision, leaving 39 patients in the liposomal bupivacaine group and 40 in the placebo group. Baseline characteristics between groups were similar. The median (interquartile range) pain score with movement at 48 hours postoperatively was 4 (2-5) in the liposomal bupivacaine group and 3.5 (2-5.5) in the placebo group (P=.72). The median (interquartile range) opioid use was 37.5 (7.5-60) morphine milligram equivalents in the liposomal bupivacaine group and 37.5 (15-75) morphine milligram equivalents in the placebo group during the first 48 hours postoperatively (P=.44). Compared with placebo, a liposomal bupivacaine incisional block at the time of cesarean delivery resulted in similar postoperative pain scores in the first 48 hours postoperatively. ClinicalTrials.gov, NCT02959996.
England, Timothy J; Hedstrom, Amanda; O'Sullivan, Saoirse; Donnelly, Richard; Barrett, David A; Sarmad, Sarir; Sprigg, Nikola; Bath, Philip M
2017-05-01
Repeated episodes of limb ischemia and reperfusion (remote ischemic conditioning [RIC]) may improve outcome after acute stroke. We performed a pilot blinded placebo-controlled trial in patients with acute ischemic stroke, randomized 1:1 to receive 4 cycles of RIC within 24 hours of ictus. The primary outcome was tolerability and feasibility. Secondary outcomes included safety, clinical efficacy (day 90), putative biomarkers (pre- and post-intervention, day 4), and exploratory hemodynamic measures. Twenty-six patients (13 RIC and 13 sham) were recruited 15.8 hours (SD 6.2) post-onset, age 76.2 years (SD 10.5), blood pressure 159/83 mm Hg (SD 25/11), and National Institutes of Health Stroke Scale (NIHSS) score 5 (interquartile range, 3.75-9.25). RIC was well tolerated with 49 out of 52 cycles completed in full. Three patients experienced vascular events in the sham group: 2 ischemic strokes and 2 myocardial infarcts versus none in the RIC group ( P =0.076, log-rank test). Compared with sham, there was a significant decrease in day 90 NIHSS score in the RIC group, median NIHSS score 1 (interquartile range, 0.5-5) versus 3 (interquartile range, 2-9.5; P =0.04); RIC augmented plasma HSP27 (heat shock protein 27; P <0.05, repeated 2-way ANOVA) and phosphorylated HSP27 ( P <0.001) but not plasma S100-β, matrix metalloproteinase-9, endocannabinoids, or arterial compliance. RIC after acute stroke is well tolerated and appears safe and feasible. RIC may improve neurological outcome, and protective mechanisms may be mediated through HSP27. A larger trial is warranted. URL: http://www.isrctn.com. Unique identifier: ISRCTN86672015. © 2017 American Heart Association, Inc.
Response to Antimalarials in Cutaneous Lupus Erythematosus A Prospective Analysis
Chang, Aileen Y.; Piette, Evan W.; Foering, Kristen P.; Tenhave, Thomas R.; Okawa, Joyce; Werth, Victoria P.
2012-01-01
Objective To demonstrate response to antimalarials in patients with cutaneous lupus erythematosus using activity scores from the Cutaneous Lupus Erythematosus Disease Area and Severity Index, a validated outcome measure. Design Prospective, longitudinal cohort study. Setting University cutaneous autoimmune disease clinic. Participants One hundred twenty-eight patients with cutaneous lupus erythematosus who presented from January 2007-July 2010 and had at least 2 visits with activity scores. Main Outcome Measures Response defined by 4-point or 20% decrease in activity score. Response to initiation determined with score before treatment and first visit at least 2 months after treatment. Response to continuation determined with score at first visit and most recent visit on treatment. Results Of 11 patients initiated on hydroxychloroquine, 55% were responders with a decrease in median (interquartile range) activity score from 8.0 (3.5-13) to 3.0 (1.8-7.3) (p=0.03). Of 15 patients who had failed hydroxychloroquine, 67% were responders to initiation of hydroxychloroquine-quinacrine, with a decrease in median (interquartile range) activity score from 6.0 (4.8-8.3) to 3.0 (0.75-5.0) (p=0.004). Nine out of 21 patients (43%) continued on hydroxychloroquine and 9 out of 21 patients (43%) continued on hydroxychloroquine-quinacrine were responders with a decrease in median (interquartile range) activity score from 6.0 (1.5-9.5) to 1.0 (0-4.5) (p=0.009) and 8.5 (4.25-17.5) to 5.0 (0.5-11.5) (p=0.01), respectively. Conclusion The use of quinacrine with hydroxychloroquine is associated with response in patients who fail hydroxychloroquine monotherapy. Further reduction in disease activity can be associated with continuation of antimalarials. PMID:21768444
Clinical presentation of patients with Ebola virus disease in Conakry, Guinea.
Bah, Elhadj Ibrahima; Lamah, Marie-Claire; Fletcher, Tom; Jacob, Shevin T; Brett-Major, David M; Sall, Amadou Alpha; Shindo, Nahoko; Fischer, William A; Lamontagne, Francois; Saliou, Sow Mamadou; Bausch, Daniel G; Moumié, Barry; Jagatic, Tim; Sprecher, Armand; Lawler, James V; Mayet, Thierry; Jacquerioz, Frederique A; Méndez Baggi, María F; Vallenas, Constanza; Clement, Christophe; Mardel, Simon; Faye, Ousmane; Faye, Oumar; Soropogui, Baré; Magassouba, Nfaly; Koivogui, Lamine; Pinto, Ruxandra; Fowler, Robert A
2015-01-01
In March 2014, the World Health Organization was notified of an outbreak of Zaire ebolavirus in a remote area of Guinea. The outbreak then spread to the capital, Conakry, and to neighboring countries and has subsequently become the largest epidemic of Ebola virus disease (EVD) to date. From March 25 to April 26, 2014, we performed a study of all patients with laboratory-confirmed EVD in Conakry. Mortality was the primary outcome. Secondary outcomes included patient characteristics, complications, treatments, and comparisons between survivors and nonsurvivors. Of 80 patients who presented with symptoms, 37 had laboratory-confirmed EVD. Among confirmed cases, the median age was 38 years (interquartile range, 28 to 46), 24 patients (65%) were men, and 14 (38%) were health care workers; among the health care workers, nosocomial transmission was implicated in 12 patients (32%). Patients with confirmed EVD presented to the hospital a median of 5 days (interquartile range, 3 to 7) after the onset of symptoms, most commonly with fever (in 84% of the patients; mean temperature, 38.6°C), fatigue (in 65%), diarrhea (in 62%), and tachycardia (mean heart rate, >93 beats per minute). Of these patients, 28 (76%) were treated with intravenous fluids and 37 (100%) with antibiotics. Sixteen patients (43%) died, with a median time from symptom onset to death of 8 days (interquartile range, 7 to 11). Patients who were 40 years of age or older, as compared with those under the age of 40 years, had a relative risk of death of 3.49 (95% confidence interval, 1.42 to 8.59; P=0.007). Patients with EVD presented with evidence of dehydration associated with vomiting and severe diarrhea. Despite attempts at volume repletion, antimicrobial therapy, and limited laboratory services, the rate of death was 43%.
Novel dry cryotherapy system for cooling the equine digit
Stefanovski, Darko; Lenfest, Margret; Chatterjee, Sraboni; Orsini, James
2018-01-01
Objectives Digital cryotherapy is commonly used for laminitis prophylaxis and treatment. Currently validated methods for distal limb cryotherapy involve wet application or compression technology. There is a need for a practical, affordable, dry cryotherapy method that effectively cools the digit. The objective of this study was to evaluate the hoof wall surface temperatures (HWSTs) achieved with a novel dry cryotherapy technology. Design Repeated-measures in vivo experimental study. Setting Experimental intervention at a single site. Participants 6 systemically healthy horses (3 mares, 3 geldings). Interventions Cryotherapy was applied to six horses for eight hours with a commercially available rubber and rubber and welded fabricice boot, which extended proximally to include the foot and pastern. Reusable malleable cold therapy packs were secured against the foot and pastern with the three built-in hook-and-loop fastener panels. Primary and secondary outcome measures HWST and pastern surface temperature of the cryotherapy-treated limb, HWST of the control limb and ambient temperature were recorded every five minutes throughout the study period. Results Results were analysed with mixed-effects multivariable regression analysis. The HWST (median 11.1°C, interquartile range 8.6°C–14.7°C) in the cryotherapy-treated limb was significantly decreased compared with the control limb (median 29.7°C, interquartile range 28.9°C–30.4°C) (P≤0.001). Cryotherapy limb HWST reached a minimum of 6.75°C (median) with an interquartile range of 4.1°C–9.3°C. Minimum HWST was achieved 68 minutes after cryotherapy pack application. Conclusions Dry application of cryotherapy significantly reduced HWST and reached minimums below the therapeutic target of 10°C. This cryotherapy method might offer an effective alternative for digital cooling. PMID:29344364
Ibrahim, Wanis H; Alousi, Faraj H; Al-Khal, Abdulatif; Bener, Abdulbari; AlSalman, Ahmed; Aamer, Aaiza; Khaled, Ahmed; Raza, Tasleem
2016-01-01
To determine the mean and median delays in pulmonary tuberculosis (PTB) diagnosis among adults in one of the world's highest gross domestic product per capita countries and identify patient and health system-related reasons for these delays. This is a cross-sectional, face-to-face, prospective study of 100 subjects with confirmed PTB, conducted at main tuberculosis (TB) admitting facilities in Qatar. The mean and median diagnostic delays were measured. The Chi-square test with two-sided P < 0.05 was considered to determine the association between factors and diagnostic delay. The mean and median total diagnostic delays of PTB were 53 (95% confidence interval [CI] 42.61-63.59) and 30 (interquartile range; Q1-Q3, 15-60) days, respectively. The mean patient factor delay was 45.7 (95% CI 28.1-63.4) days, and the median was 30 (interquartile range; Q1-Q3, 15-60) days. The mean health system factor delay was 46.3 (95% CI 35.46-57.06) days, and the median was 30 (interquartile range; Q1-Q3, 18-60) days. The most common cause of patient factor delay was neglect of TB symptoms by patients (in 39% of cases), and for health-care system factor delay was a failure (mostly at general and private care levels) to suspect PTB by doctors (in 57% of cases). There were no significant associations between the presence of language barrier, patient occupation or nationality, and diagnostic delay. Despite a favorable comparison to other countries, there is a substantial delay in the diagnosis of PTB in Qatar. Relevant actions including health education on TB are required to minimize this delay.
CDH1 gene polymorphisms, plasma CDH1 levels and risk of gastric cancer in a Chinese population.
Zhan, Zhen; Wu, Juan; Zhang, Jun-Feng; Yang, Ya-Ping; Tong, Shujuan; Zhang, Chun-Bing; Li, Jin; Yang, Xue-Wen; Dong, Wei
2012-08-01
The genetic polymorphisms in E-cadherin gene (CDH1) may affect invasive/metastatic development of gastric cancer by altering gene transcriptional activity of epithelial cell. Our study aims to explore the associations among CDH1 gene polymorphisms, and predisposition of gastric cancer. We genotyped four potentially functional polymorphisms (rs13689, rs1801552, rs16260 and rs17690554) of the CDH1 gene in a case-control study of 387 incident gastric cancer cases and 392 healthy controls by polymerase chain reaction-ligation detection reaction methods (PCR-LDR) and measured the plasma CDH1 levels using enzyme immunoassay among the subjects. The median and inter-quartile range were adopted for representing the mean level of non-normally distributed data, and we found the level of plasma CDH1 in gastric cancer patients (median: 171.00 pg/ml; inter-quartile range: 257.10 pg/ml) were significantly higher than that of controls (median: 137.40 pg/ml; inter-quartile range: 83.90 pg/ml, P = 0.003). However, none of the four polymorphisms or their haplotypes achieved significant differences in their distributions between gastric cancer cases and controls, and interestingly, in the subgroup analysis of gastric cancer, we found that CA genotype of rs26160 and CG genotype of rs17690554 were associated with the risk of diffuse gastric cancer, compared with their wild genotypes (OR = 2.98, 95 % CI: 1.60-5.53; OR = 2.10, 95 % CI: 1.14-3.85, respectively, P < 0.05). In conclusion, our results indicated that plasma CDH1 levels may serve as a risk marker against gastric cancer and variant genotypes of rs26160 and rs17690554 may contribute to the etiology of diffuse gastric cancer in this study. Further studies are warranted to verify these findings.
de Iudicibus, Gianfranco; Cremer, Olaf L.; Ong, David S. Y.; van der Poll, Tom; Bos, Lieuwe D.; Schultz, Marcus J.
2018-01-01
Background Macrolides have been associated with favorable immunological effects in various inflammatory disease states. We investigated the association between macrolide therapy and mortality in patients with the acute respiratory distress syndrome (ARDS). Methods This was an unplanned secondary analysis of patients with ARDS within a large prospective observational study of critically ill patients in the intensive care units (ICUs) of two university-affiliated hospitals in the Netherlands. The exposure of interest was low-dose macrolide use prescribed for another reason than infection; we excluded patients who received high-dose macrolides for an infection. The primary endpoint was 30-day mortality. The association between macrolide therapy and mortality was determined in the whole cohort, as well as in a propensity score matched cohort; the association was compared between pulmonary versus non-pulmonary ARDS, and between two biological phenotypes based on plasma levels of 20 biomarkers. Results In total, 873 patients with ARDS were analyzed, of whom 158 patients (18%) received macrolide therapy during stay in ICU for a median duration of 3 (interquartile range, 1–4) days. Erythromycin was the most frequent prescribed macrolide (97%). Macrolide therapy was associated with reduced 30-day mortality in the whole cohort [22.8% vs. 31.6%; crude odds ratio (OR), 0.64 (interquartile range, 0.43–0.96), P=0.03]. The association in the propensity score matched cohort remained significant [22.8% vs. 32.9%; OR, 0.62 (interquartile range, 0.39–0.96), P=0.03]. Propensity matched associations with mortality were different in patients with non-pulmonary ARDS vs. pulmonary ARDS and also varied by biological phenotype. Conclusions These data together show that low-dose macrolide therapy prescribed for another reason than infection is associated with decreased mortality in patients with ARDS. PMID:29430441
Cheuk, Queenie K Y; Lo, T K; Lee, C P; Yeung, Anita P C
2015-06-01
To evaluate the efficacy and safety of double balloon catheter for induction of labour in Chinese women with one previous caesarean section and unfavourable cervix at term. Retrospective cohort study. A regional hospital in Hong Kong. Women with previous caesarean delivery requiring induction of labour at term and with an unfavourable cervix from May 2013 to April 2014. Primary outcome was to assess rate of successful vaginal delivery (spontaneous or instrument-assisted) using double balloon catheter. Secondary outcomes were double balloon catheter induction-to-delivery and removal-to-delivery interval; cervical score improvement; oxytocin augmentation; maternal or fetal complications during cervical ripening, intrapartum and postpartum period; and risk factors associated with unsuccessful induction. All 24 Chinese women tolerated double balloon catheter well. After double balloon catheter expulsion or removal, the cervix successfully ripened in 18 (75%) cases. The improvement in Bishop score 3 (interquartile range, 2-4) was statistically significant (P<0.001). Overall, 18 (75%) cases were delivered vaginally. The median insertion-to-delivery and removal-to-delivery intervals were 19 (interquartile range, 13.4-23.0) hours and 6.9 (interquartile range, 4.1-10.8) hours, respectively. Compared with cases without, the interval to delivery was statistically significantly shorter in those with spontaneous balloon expulsion or spontaneous membrane rupture during ripening (7.8 vs 3.0 hours; P=0.025). There were no major maternal or neonatal complications. The only factor significantly associated with failed vaginal birth after caesarean was previous caesarean section for failure to progress (P<0.001). This is the first study using double balloon catheter for induction of labour in Asian Chinese women with previous caesarean section. Using double balloon catheter, we achieved a vaginal birth after caesarean rate of 75% without major complications.
St Louis, James D; Jodhka, Upinder; Jacobs, Jeffrey P; He, Xia; Hill, Kevin D; Pasquali, Sara K; Jacobs, Marshall L
2014-12-01
Contemporary outcomes data for complete atrioventricular septal defect (CAVSD) repair are limited. We sought to describe early outcomes of CAVSD repair across a large multicenter cohort, and explore potential associations with patient characteristics, including age, weight, and genetic syndromes. Patients in the Society of Thoracic Surgeons Congenital Heart Surgery Database having repair of CAVSD (2008-2011) were included. Preoperative, operative, and outcomes data were described. Univariate associations between patient factors and outcomes were described. Of 2399 patients (101 centers), 78.4% had Down syndrome. Median age at surgery was 4.6 months (interquartile range, 3.5-6.1 months), with 11.8% (n = 284) aged ≤ 2.5 months. Median weight at surgery was 5.0 kg (interquartile range, 4.3-5.8 kg) with 6.3% (n = 151) < 3.5 kg. Pulmonary artery band removal at CAVSD repair was performed in 122 patients (4.6%). Major complications occurred in 9.8%, including permanent pacemaker implantation in 2.7%. Median postoperative length of stay (PLOS) was 8 days (interquartile range, 5-14 days). Overall hospital mortality was 3.0%. Weight < 3.5 kg and age ≤ 2.5 months were associated with higher mortality, longer PLOS, and increased frequency of major complications. Patients with Down syndrome had lower rates of mortality and morbidities than other patients; PLOS was similar. In a contemporary multicenter cohort, most patients with CAVSD have repair early in the first year of life. Prior pulmonary artery band is rare. Hospital mortality is generally low, although patients at extremes of low weight and younger age have worse outcomes. Mortality and major complication rates are lower in patients with Down syndrome. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Del Razo, Luz M; García-Vargas, Gonzalo G; Valenzuela, Olga L; Castellanos, Erika Hernández; Sánchez-Peña, Luz C; Currier, Jenna M; Drobná, Zuzana; Loomis, Dana; Stýblo, Miroslav
2011-08-24
Human exposures to inorganic arsenic (iAs) have been linked to an increased risk of diabetes mellitus. Recent laboratory studies showed that methylated trivalent metabolites of iAs may play key roles in the diabetogenic effects of iAs. Our study examined associations between chronic exposure to iAs in drinking water, metabolism of iAs, and prevalence of diabetes in arsenicosis-endemic areas of Mexico. We used fasting blood glucose (FBG), fasting plasma insulin (FPI), oral glucose tolerance test (OGTT), glycated hemoglobin (HbA1c), and insulin resistance (HOMA-IR) to characterize diabetic individuals. Arsenic levels in drinking water and urine were determined to estimate exposure to iAs. Urinary concentrations of iAs and its trivalent and pentavalent methylated metabolites were measured to assess iAs metabolism. Associations between diabetes and iAs exposure or urinary metabolites of iAs were estimated by logistic regression with adjustment for age, sex, hypertension and obesity. The prevalence of diabetes was positively associated with iAs in drinking water (OR 1.13 per 10 ppb, p < 0.01) and with the concentration of dimethylarsinite (DMAsIII) in urine (OR 1.24 per inter-quartile range, p = 0.05). Notably, FPI and HOMA-IR were negatively associated with iAs exposure (β -2.08 and -1.64, respectively, p < 0.01), suggesting that the mechanisms of iAs-induced diabetes differ from those underlying type-2 diabetes, which is typically characterized by insulin resistance. Our study confirms a previously reported, but frequently questioned, association between exposure to iAs and diabetes, and is the first to link the risk of diabetes to the production of one of the most toxic metabolites of iAs, DMAsIII.
2011-01-01
Background Human exposures to inorganic arsenic (iAs) have been linked to an increased risk of diabetes mellitus. Recent laboratory studies showed that methylated trivalent metabolites of iAs may play key roles in the diabetogenic effects of iAs. Our study examined associations between chronic exposure to iAs in drinking water, metabolism of iAs, and prevalence of diabetes in arsenicosis-endemic areas of Mexico. Methods We used fasting blood glucose (FBG), fasting plasma insulin (FPI), oral glucose tolerance test (OGTT), glycated hemoglobin (HbA1c), and insulin resistance (HOMA-IR) to characterize diabetic individuals. Arsenic levels in drinking water and urine were determined to estimate exposure to iAs. Urinary concentrations of iAs and its trivalent and pentavalent methylated metabolites were measured to assess iAs metabolism. Associations between diabetes and iAs exposure or urinary metabolites of iAs were estimated by logistic regression with adjustment for age, sex, hypertension and obesity. Results The prevalence of diabetes was positively associated with iAs in drinking water (OR 1.13 per 10 ppb, p < 0.01) and with the concentration of dimethylarsinite (DMAsIII) in urine (OR 1.24 per inter-quartile range, p = 0.05). Notably, FPI and HOMA-IR were negatively associated with iAs exposure (β -2.08 and -1.64, respectively, p < 0.01), suggesting that the mechanisms of iAs-induced diabetes differ from those underlying type-2 diabetes, which is typically characterized by insulin resistance. Conclusions Our study confirms a previously reported, but frequently questioned, association between exposure to iAs and diabetes, and is the first to link the risk of diabetes to the production of one of the most toxic metabolites of iAs, DMAsIII. PMID:21864395
Automated external defibrillators and simulated in-hospital cardiac arrests.
Rossano, Joseph W; Jefferson, Larry S; Smith, E O'Brian; Ward, Mark A; Mott, Antonio R
2009-05-01
To test the hypothesis that pediatric residents would have shorter time to attempted defibrillation using automated external defibrillators (AEDs) compared with manual defibrillators (MDs). A prospective, randomized, controlled trial of AEDs versus MDs was performed. Pediatric residents responded to a simulated in-hospital ventricular fibrillation cardiac arrest and were randomized to using either an AED or MD. The primary end point was time to attempted defibrillation. Sixty residents, 21 (35%) interns, were randomized to 2 groups (AED = 30, MD = 30). Residents randomized to the AED group had a significantly shorter time to attempted defibrillation [median, 60 seconds (interquartile range, 53 to 71 seconds)] compared with those randomized to the MD group [median, 103 seconds (interquartile range, 68 to 288 seconds)] (P < .001). All residents in the AED group attempted defibrillation at <5 minutes compared with 23 (77%) in the MD group (P = .01). AEDs improve the time to attempted defibrillation by pediatric residents in simulated cardiac arrests. Further studies are needed to help determine the role of AEDs in pediatric in-hospital cardiac arrests.
Changing Epidemiology of Human Brucellosis, China, 1955-2014.
Lai, Shengjie; Zhou, Hang; Xiong, Weiyi; Gilbert, Marius; Huang, Zhuojie; Yu, Jianxing; Yin, Wenwu; Wang, Liping; Chen, Qiulan; Li, Yu; Mu, Di; Zeng, Lingjia; Ren, Xiang; Geng, Mengjie; Zhang, Zike; Cui, Buyun; Li, Tiefeng; Wang, Dali; Li, Zhongjie; Wardrop, Nicola A; Tatem, Andrew J; Yu, Hongjie
2017-02-01
Brucellosis, a zoonotic disease, was made statutorily notifiable in China in 1955. We analyzed the incidence and spatial-temporal distribution of human brucellosis during 1955-2014 in China using notifiable surveillance data: aggregated data for 1955-2003 and individual case data for 2004-2014. A total of 513,034 brucellosis cases were recorded, of which 99.3% were reported in northern China during 1955-2014, and 69.1% (258, 462/374, 141) occurred during February-July in 1990-2014. Incidence remained high during 1955-1978 (interquartile range 0.42-1.0 cases/100,000 residents), then decreased dramatically in 1979-1994. However, brucellosis has reemerged since 1995 (interquartile range 0.11-0.23 in 1995-2003 and 1.48-2.89 in 2004-2014); the historical high occurred in 2014, and the affected area expanded from northern pastureland provinces to the adjacent grassland and agricultural areas, then to southern coastal and southwestern areas. Control strategies in China should be adjusted to account for these changes by adopting a One Health approach.
Luttmann-Gibson, Heike; Sarnat, Stefanie Ebelt; Suh, Helen H; Coull, Brent A; Schwartz, Joel; Zanobetti, Antonella; Gold, Diane R
2014-02-01
We examine whether ambient air pollution is associated with oxygen saturation in 32 elderly subjects in Steubenville, Ohio. We used linear mixed models to examine the effects of fine particulate matter less than 2.5 μm (PM(2.5)), sulfate (SO(4)(-2)), elemental carbon, and gases on median oxygen saturation. An interquartile range increase of 13.4 μg/m in PM(2.5) on the previous day was associated with a decrease of -0.18% (95% confidence interval: -0.31 to -0.06) and a 5.1 μg/m(3) interquartile range increase in SO(4)(-2) on the previous day was associated with a decrease of -0.16% (95% confidence interval: -0.27 to -0.04) in oxygen saturation during the initial 5-minute rest period of the protocol. Increased exposure to air pollution, including the nontraffic pollutant SO(4)(-2) from industrial sources, led to changes in oxygen saturation that may reflect particle-induced pulmonary inflammatory or vascular responses.
Cancer patient experience, hospital performance and case mix: evidence from England.
Abel, Gary A; Saunders, Catherine L; Lyratzopoulos, Georgios
2014-01-01
This study aims to explore differences between crude and case mix-adjusted estimates of hospital performance with respect to the experience of cancer patients. This study analyzed the English 2011/2012 Cancer Patient Experience Survey covering all English National Health Service hospitals providing cancer treatment (n = 160). Logistic regression analysis was used to predict hospital performance for each of the 64 evaluative questions, adjusting for age, gender, ethnic group and cancer diagnosis. The degree of reclassification was explored across three categories (bottom 20%, middle 60% and top 20% of hospitals). There was high concordance between crude and adjusted ranks of hospitals (median Kendall's τ = 0.84; interquartile range: 0.82-0.88). Across all questions, a median of 5.0% (eight) of hospitals (interquartile range: 3.8-6.4%; six to ten hospitals) moved out of the extreme performance categories after case mix adjustment. In this context, patient case mix has only a small impact on measured hospital performance for cancer patient experience.
Sawinski, Deirdre; Patel, Nikunjkumar; Appolo, Brenda; Bloom, Roy
2017-05-01
Hepatitis C virus (HCV) infection is prevalent in the renal transplant population but direct acting antiviral agents (DAA) provide an effective cure of HCV infection without risk of allograft rejection. We report our experience treating 43 renal transplant recipients with 4 different DAA regimens. One hundred percent achieved a sustained viral response by 12 weeks after therapy, and DAA regimens were well tolerated. Recipients transplanted with a HCV+ donor responded equally well to DAA therapy those transplanted with a kidney from an HCV- donor, but recipients of HCV+ organs experienced significantly shorter wait times to transplantation, 485 days (interquartile range, 228-783) versus 969 days (interquartile range, 452-2008; P = 0.02). On this basis, we advocate for a strategy of early posttransplant HCV eradication to facilitate use of HCV+ organs whenever possible. Additional studies are needed to identify the optimal DAA regimen for kidney transplant recipients, accounting for efficacy, timing relative to transplant, posttransplant clinical outcomes, and cost.
Durga, Padmaja; Raavula, Parvathi; Gurajala, Indira; Gunnam, Poojita; Veerabathula, Prardhana; Reddy, Mukund; Upputuri, Omkar; Ramachandran, Gopinath
2015-09-01
To assess the effect of tranexamic acid on the quality of the surgical field. Prospective, randomized, double-blind study. Institutional, tertiary referral hospital. American Society of Anesthesiologists physical status class I patients, aged 8 to 60 months with Group II or III (Balakrishnan's classification) clefts scheduled for cleft palate repair. Children were randomized into two groups. The control group received saline, and the tranexamic acid group received tranexamic acid 10 mg/kg as a bolus, 15 minutes before incision. Grade of surgical field on a 10-point scale, surgeon satisfaction, and primary hemorrhage. Significant improvements were noted in surgeon satisfaction and median grade of assessment of the surgical field (4 [interquartile range, 4 to 6] in the control group vs. 3 [interquartile range, 2 to 4] in the test group; P = .003) in the tranexamic acid group compared to the control group. Preincision administration of 10 mg/kg of tranexamic acid significantly improved the surgical field during cleft palate repair.
Stone, M; Collins, A L; Silins, U; Emelko, M B; Zhang, Y S
2014-03-01
There is increasing global concern regarding the impacts of large scale land disturbance by wildfire on a wide range of water and related ecological services. This study explores the impact of the 2003 Lost Creek wildfire in the Crowsnest River basin, Alberta, Canada on regional scale sediment sources using a tracing approach. A composite geochemical fingerprinting procedure was used to apportion the sediment efflux among three key spatial sediment sources: 1) unburned (reference) 2) burned and 3) burned sub-basins that were subsequently salvage logged. Spatial sediment sources were characterized by collecting time-integrated suspended sediment samples using passive devices during the entire ice free periods in 2009 and 2010. The tracing procedure combines the Kruskal-Wallis H-test, principal component analysis and genetic-algorithm driven discriminant function analysis for source discrimination. Source apportionment was based on a numerical mass balance model deployed within a Monte Carlo framework incorporating both local optimization and global (genetic algorithm) optimization. The mean relative frequency-weighted average median inputs from the three spatial source units were estimated to be 17% (inter-quartile uncertainty range 0-32%) from the reference areas, 45% (inter-quartile uncertainty range 25-65%) from the burned areas and 38% (inter-quartile uncertainty range 14-59%) from the burned-salvage logged areas. High sediment inputs from burned and the burned-salvage logged areas, representing spatial source units 2 and 3, reflect the lasting effects of forest canopy and forest floor organic matter disturbance during the 2003 wildfire including increased runoff and sediment availability related to high terrestrial erosion, streamside mass wasting and river bank collapse. The results demonstrate the impact of wildfire and incremental pressures associated with salvage logging on catchment spatial sediment sources in higher elevation Montane regions where forest growth and vegetation recovery are relatively slow. Copyright © 2013 Elsevier B.V. All rights reserved.
Manickum, T; John, W; Terry, S; Hodgson, K
2014-11-01
Raw and potable water sample sources, from the Umgeni Water catchment areas (rivers, dams, boreholes) in central KwaZulu-Natal (South Africa), were screened for Uranium concentration and alpha and beta radioactivity. Test methods used were gas flow proportional counting for alpha-beta radioactivity, and kinetic phosphorescence analysis (KPA), for Uranium. The uranium levels (median = 0.525 μg/L, range = <0.050-5.010) were well below the international World Health Organization (WHO) (2011) guideline for drinking-water quality (≤15 μg/L). The corresponding alpha and beta radioactivity was ≤0.5 Bq/L (median = 0.084, Interquartile Range (IR) = 0.038, range = 0.018-0.094), and ≤1.0 Bq/L (median = 0.114, IR = 0.096, range = 0.024-0.734), respectively, in compliance with the international WHO limits. For uranium radionuclide, the average dose level, at uranium level of ±0.525 μg/L, was 0.06 μSv/a, which complies with the WHO reference dose level for drinking water (<0.1 mSv/a). There was a distinct trend of cluster of relatively higher Uranium levels of some sources that were found to be associated with the geology/geography and groundwater sources. Overall, the radiological water quality classification, with respect to WHO, is "Blue" - ideal; additional physicochemical analyses indicated good water quality. The analytical test methods employed were found to be suitable for preliminary screening for potential radioactive "hot spots". The observed Uranium levels, and the alpha/beta radioactivity, indicate contribution largely from Naturally Occurring Radioactive Material (NORM), with no significant health risk to humans, or to the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Herwald, Sanna E; Spies, James B; Yucel, E Kent
2017-02-01
The first participants in the independent interventional radiology (IR) residency match will begin prerequisite diagnostic radiology (DR) residencies before the anticipated launch of the independent IR programs in 2020. The aim of this study was to estimate the competitiveness level of the first independent IR residency matches before these applicants have already committed to DR residencies and possibly early specialization in IR (ESIR) programs. The Society of Chairs of Academic Radiology Departments (SCARD) Task Force on the IR Residency distributed a survey to all active SCARD members using SurveyMonkey. The survey requested the number of planned IR residency and ESIR positions. The average, minimum, and maximum of the range of planned independent IR residency positions were compared with the average, maximum, and minimum, respectively, of the range of planned ESIR positions, to model matches of average, high, and low competitiveness. Seventy-four active SCARD members (56%) answered at least one survey question. The respondents' programs planned to fill, in total, 98 to 102 positions in integrated IR residency programs, 61 to 76 positions in independent IR residency programs, and 50 to 77 positions in ESIR DR residency programs each year. The ranges indicate the uncertainty of some programs regarding the number of positions. The survey suggests that participating programs will fill sufficient independent IR residency positions to accommodate all ESIR applicants in a match year of average or low competitiveness, but not in a match year of high competitiveness. This suggestion does not account for certain difficult-to-predict factors that may affect the independent IR residency match. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Lunden, Jason B; Muffenbier, Mike; Giveans, M Russell; Cieminski, Cort J
2010-09-01
Clinical measurement, reliability. To compare intrarater and interrater reliability of shoulder internal rotation (IR) passive range of motion measurements utilizing a standard supine position and a sidelying position. Glenohumeral IR range of motion deficits are often noted in patients with shoulder pathology. Excellent intrarater reliability has been found when measuring this motion. However, interrater reliability has been reported as poor to fair. Some clinicians currently use a sidelying position for IR stretching with patients who have shoulder pathology. However, no objective data exist for IR passive range of motion measured in this sidelying position, either in terms of reliability or normative values. Seventy subjects (mean age, 36.8 years), with (n = 19) and without (n = 51) shoulder pathology, were included in this study. Shoulder IR passive range of motion of the dominant shoulder or involved shoulder was measured by 2 investigators in 2 positions: (1) a standard supine position, with the shoulder at 90 degrees of abduction, and (2) in sidelying on the tested side, with the shoulder flexed to 90 degrees . Intrarater reliability for supine measurements was good to excellent (ICC3,1 = 0.70-0.93) and for sidelying measurements was excellent (ICC3,1 = 0.94-0.98). Interrater reliability was fair to good for the supine measurement (ICC2,2 = 0.74-0.81) and good to excellent for the sidelying measurement (ICC2,2 = 0.88-0.96). The mean (range) value of the dominant shoulder sidelying IR passive range of motion was 40 degrees (11 degrees to 69 degrees ) for healthy subjects and 25 degrees (-16 degrees to 49 degrees) for subjects with shoulder pathology. For subjects with shoulder pathology, measurements of shoulder IR made in the sidelying position had superior intrarater and interrater reliability compared to those in the standard supine position.
The recent and prospective developments of cooled IR FPAs for double application at Electron NRI
NASA Astrophysics Data System (ADS)
Arutunov, V. A.; Vasilyev, I. S.; Ivanov, V. G.; Prokofyev, A. E.
2003-09-01
The recent and prospective developments of monolithic silicon IR-Schottky-barrier staring focal plane arrays (IR SB FPAs), photodetector assembly, and digital thermal imaging cameras (TICs) at Electron National Research Institute (Electron NRI) are considered. Basic parameters for IR SB FPAs with 256x256 and 512x512 pixels, and TICs based on these arrays are presented. The problems emerged while proceeding from the developments of IR SB FPAs for the wavelength range from 3 μm to 5 μm to the developments of those ones for xLWIR range are indicated (an abrupt increase in the level of background architecture). Possibility for further improvement in basic parameters of IR SB FPAs are discussed (a decrease in threshold signal power down to 0.5-1.0"1013 W/element with an increase in quantum efficiency, a decrease in output noise and proceeding to Schottky barriers of degenerated semiconductor/silicon heterojunction, and implementation of these array parameters in photodetector assembly with improved thermal background shielding taking into consideration an optical structure of TIC for concrete application). It is concluded that relative simplicity of the technology and expected low cost of monolithic silicon IR SB FPAs with basic parameters compared with hybrid IR FPAs for the wavelength ranges from 3 μm to 5 μm and from 8 μm to 12 μm maintain large monolithic IR SB FPAs as a basis for developments of double application digital TICs in the Russian Federation.
Shoulder rotational profiles in young healthy elite female and male badminton players.
Couppé, C; Thorborg, K; Hansen, M; Fahlström, M; Bjordal, J M; Nielsen, D; Baun, M; Storgaard, M; Magnusson, S P
2014-02-01
The aim of the present study was to profile shoulder passive range of motion (ROM) and isometric strength for external (ER) and internal (IR) rotation as part of a preseason screening in adolescent national badminton players. Passive external range of motion (EROM) and internal range of motion (IROM) were examined on the dominant and nondominant shoulder in 31 adolescent national badminton players (12 females and 19 males) with a standard goniometer. Muscle strength was examined with a hand-held dynamometer in ER and IR. Total range of motion (TROM = EROM+IROM) was lower on the dominant side compared with the nondominant side in both groups (P < 0.001). Males were generally stronger than females in all strength measurements except for IR on the dominant side (P < 0.01). In females, IR dominant side strength was greater compared with IR on the nondominant side (P < 0.05). TROM was reduced on the dominant side compared with the nondominant side in young elite badminton players, irrespective of gender. No rotational strength differences existed between the dominant and nondominant side in male players, but in female players a higher IR strength on the dominant side was not balanced by a higher ER strength. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Tobin, W Oliver; Guo, Yong; Krecke, Karl N; Parisi, Joseph E; Lucchinetti, Claudia F; Pittock, Sean J; Mandrekar, Jay; Dubey, Divyanshu; Debruyne, Jan; Keegan, B Mark
2017-09-01
Chronic lymphocytic inflammation with pontine perivascular enhancement responsive to steroids (CLIPPERS) is a central nervous system inflammatory syndrome predominantly affecting the brainstem, cerebellum, and spinal cord. Following its initial description, the salient features of CLIPPERS have been confirmed and expanded upon, but the lack of formalized diagnostic criteria has led to reports of patients with dissimilar features purported to have CLIPPERS. We evaluated clinical, radiological and pathological features of patients referred for suspected CLIPPERS and propose diagnostic criteria to discriminate CLIPPERS from non-CLIPPERS aetiologies. Thirty-five patients were evaluated for suspected CLIPPERS. Clinical and neuroimaging data were reviewed by three neurologists to confirm CLIPPERS by consensus agreement. Neuroimaging and neuropathology were reviewed by experienced neuroradiologists and neuropathologists, respectively, both of whom were blinded to the clinical data. CLIPPERS was diagnosed in 23 patients (18 male and five female) and 12 patients had a non-CLIPPERS diagnosis. CLIPPERS patients' median age of onset was 58 years (interquartile range, 24-72) and were followed a median of 44 months (interquartile range 38-63). Non-CLIPPERS patients' median age of onset was 52 years (interquartile range, 39-59) and were followed a median of 27 months (interquartile range, 14-47). Clinical symptoms of gait ataxia, diplopia, cognitive impairment, and facial paraesthesia did not discriminate CLIPPERS from non-CLIPPERS. Marked clinical and radiological corticosteroid responsiveness was observed in CLIPPERS (23/23), and clinical worsening occurred in all 12 CLIPPERS cases when corticosteroids were discontinued. Corticosteroid responsiveness was common but not universal in non-CLIPPERS [clinical improvement (8/12); radiological improvement (2/12); clinical worsening on discontinuation (3/8)]. CLIPPERS patients had brainstem predominant perivascular gadolinium enhancing lesions on magnetic resonance imaging that were discriminated from non-CLIPPERS by: homogenous gadolinium enhancing nodules <3 mm in diameter without ring-enhancement or mass effect, and homogenous T2 signal abnormality not significantly exceeding the T1 enhancement. Brain neuropathology on 14 CLIPPERS cases demonstrated marked CD3-positive T-lymphocyte, mild B-lymphocyte and moderate macrophage infiltrates, with perivascular predominance as well as diffuse parenchymal infiltration (14/14), present in meninges, white and grey matter, associated with variable tissue destruction, astrogliosis and secondary myelin loss. Clinical, radiological and pathological feature define CLIPPERS syndrome and are differentiated from non-CLIPPERS aetiologies by neuroradiological and neuropathological findings. © The Author (2017). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rapid discrimination of Panax notogeinseng of different grades by FT-IR and 2DCOS-IR
NASA Astrophysics Data System (ADS)
Ma, Fang; Chen, Jian-bo; Wu, Xian-xue; Zhou, Qun; Sun, Su-qin
2016-11-01
The herbal material of Notoginseng (the root of Panax notoginseng) is sold by "Tou" (the number of Notoginseng in every 500 g) to distinguish the grade. Normally the better quality, the few number of the "Tou" and the size of Notoginseng is bigger. In this study, three grades of Notoginseng harvested from Yunnan province were discriminated and identified by Fourier transform infrared spectroscopy (FT-IR) and two-dimensional correlation infrared spectroscopy (2DCOS-IR)). The correlation coefficient of IR spectra between the three grades of Notoginseng and starch are greater than 0.95 in the range of 1300-800 cm-1, means the main compositions of Notoginseng are starch polysaccharide. Also, when the size of Notoginseng is bigger, it may contain more polysaccharide. There is no difference in range of 815-1000 cm-1 of the 2DCOS-IR synchronous spectra of the three grades means polysaccharides possess good thermal stability. In the range of 1200-1300 cm-1 shows the inverse ration between the thermal sensitivity of C-O and the number of "Tou". Combination with the 2DCOS-IR asynchronous spectra, the response speed of amino acid (1640 cm-1) on the thermal perturbation is the fastest, followed by nitrate (1384 cm-1); the response speed of polysaccharides (1079 cm-1) is the slowest. The result proved that the 2DCOS-IR could discriminate different grades of Notoginseng.
Adverse events and dropouts in Alzheimer's disease studies: what can we learn?
Henley, David B; Sundell, Karen L; Sethuraman, Gopalan; Schneider, Lon S
2015-01-01
Interpreting Alzheimer's disease (AD) clinical trial (CT) outcomes is complicated by treatment dropouts and adverse events (AEs). In elderly participants, AE rates, dropouts, and deaths are important considerations as they may undermine the validity of clinical trials. Published discontinuation and safety data are limited. Safety data from 1054 placebo-treated participants in IDENTITY and IDENTITY-2, 76-week, Phase 3 AD studies conducted in 31 countries, were pooled, annualized, and summarized overall, by country and age group. Median age was 74.2 (interquartile range 67.9-79.5) years; 57.4% were female; and median observation time was 63.2 (interquartile range 41.6-77.4) weeks when study drug dosing was halted. Overall annualized rates for discontinuations, discontinuations due to AEs, serious adverse events (SAEs), and deaths were 21.6% (range 19.6%-24.0%), 8.2% (range 8.1%-8.3%), 12.0%, and 1.7%, respectively. AE and discontinuation rates varied by country and age groups. Fall, pneumonia, and atrial fibrillation AEs were more frequent in the oldest age group. These annualized placebo safety data provide insight into the course of enrolled patients with mild-to-moderate AD, and are useful in planning longer term trials and in monitoring safety. Copyright © 2015 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
[Fluoride content of bottled natural mineral waters in Spain and prevention of dental caries].
Maraver, Francisco; Vitoria, Isidro; Almerich-Silla, José Manuel; Armijo, Francisco
2015-01-01
The aim of the study was to determine the concentration of fluoride in natural mineral waters marketed in Spain in order to prevent tooth decay without the risk of causing dental fluorosis Descriptive and cross-sectional study during 2012. Natural mineral waters marketed in Spain. Three bottles with different bottling dates of 109 natural mineral waters (97 Spanish and 12 imported brands). Determination of fluoride by ion chromatography Median fluoride concentrations of the natural mineral waters bottled in Spain was 0.22 (range 0.00-4.16; interquartile range:0.37). Most samples (61 brands, 62%) contained less than 0.3mg/L. There are 19 Spanish brands with more than 0.6 mg/L. The median level in imported brands was 0.35 (range 0.10-1.21; interquartile range: 0.23). Only 28 of the 109 brands examined (25.6%) specified the fluoride content on the label. Good correlation was observed between the concentrations indicated and those determined. Fluoride concentrations in natural mineral waters showed high variation. Given the growing consumption of natural mineral waters in Spain, this type of information is important to make proper use of fluoride in the primary prevention of dental caries. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.
Quah, H M; Seow-Choen, F
2004-03-01
This study was designed to compare diathermy excision and diathermy coagulation in the treatment of symptomatic prolapsed piles. Forty-five consecutive patients were randomly assigned to diathermy excision hemorrhoidectomy (Group A, n = 25) and diathermy coagulation (Group B, n = 20) under general anesthesia. The median duration of surgery was ten minutes for both groups. There was no statistical difference in the severity of postoperative pain at rest between the two groups, but Group A patients felt less pain during defecation on the third postoperative day (median, 5 (interquartile range, 3-7) vs. 8 (4-9); P = 0.04) and on the sixth postoperative day (median, 5 (interquartile range, 2-6) vs. 9 (5-10); P = 0.02). There was, however, no statistical difference in postoperative oral analgesics use and patients' satisfaction scores between the two groups. Complication rates were similar except that diathermy coagulation tended to leave some residual skin components of external hemorrhoid especially in very large prolapsed piles. Group A patients resumed work earlier (mean, 12 (range, 4-20) vs. 17 (11-21) days); however, this was not statistically significant ( P = 0.1). Diathermy coagulation of hemorrhoids is a simple technique and may be considered in suitable cases.
High operating temperature IR-modules with reduced pitch for SWaP sensitive applications
NASA Astrophysics Data System (ADS)
Breiter, R.; Wendler, J.; Lutz, H.; Rutzinger, S.; Ihle, T.; Ziegler, J.; Rühlich, I.
2011-06-01
Low size, weight and power (SWaP) are the most critical requirements for portable thermal imagers like weapon sights or handheld observations devices. On the other hand due to current asymmetrical conflicts there are high requirements for the e/o performance of these devices providing the ability to distinguish between combatants and non-combatants in adequate ranges. Despite of all the success with uncooled technology, such requirements usually still require cooled detectors. AIM has developed a family of thermal weapon sights called HuntIR and RangIR based on high performance cooled IR-modules which are used e.g. in the infantryman of the future program of the German army (IdZ). The specific capability of these devices is a high ID range >1500m for tank targets being suitable in use as thermal sights for .50 cal rifles like the G82, targeting units for the 40mm AGL or for night observation. While such ranges sound far beyond the operational needs in urban operations, the a.m. specific needs of asymmetric warfare require sometimes even more range performance. High operating temperature (HOT) is introduced in the AIM MCT 640x512/15μm MWIR or LWIR modules for further reduction of cooler power consumption, shorter cooldown times and higher MTTF. As a key component to keep performance while further reducing SWaP AIM is developing a new cooled MCT IR-module with reduced pitch of 12 μm operating at a temperature >120 K. The module will provide full TV format with 640x480 elements sensitive in the MWIR spectral band. The paper will show recent results of AIM IR-modules with high operating temperature and the impact of design regarding the IR-module itself and thermal sights making use of it.
Left ventricular hypertrophy with strain and aortic stenosis.
Shah, Anoop S V; Chin, Calvin W L; Vassiliou, Vassilis; Cowell, S Joanna; Doris, Mhairi; Kwok, T'ng Choong; Semple, Scott; Zamvar, Vipin; White, Audrey C; McKillop, Graham; Boon, Nicholas A; Prasad, Sanjay K; Mills, Nicholas L; Newby, David E; Dweck, Marc R
2014-10-28
ECG left ventricular hypertrophy with strain is associated with an adverse prognosis in aortic stenosis. We investigated the mechanisms and outcomes associated with ECG strain. One hundred and two patients (age, 70 years [range, 63-75 years]; male, 66%; aortic valve area, 0.9 cm(2) [range, 0.7-1.2 cm(2)]) underwent ECG, echocardiography, and cardiovascular magnetic resonance. They made up the mechanism cohort. Myocardial fibrosis was determined with late gadolinium enhancement (replacement fibrosis) and T1 mapping (diffuse fibrosis). The relationship between ECG strain and cardiovascular magnetic resonance was then assessed in an external validation cohort (n=64). The outcome cohort was made up of 140 patients from the Scottish Aortic Stenosis and Lipid Lowering Trial Impact on Regression (SALTIRE) study and was followed up for 10.6 years (1254 patient-years). Compared with those without left ventricular hypertrophy (n=51) and left ventricular hypertrophy without ECG strain (n=30), patients with ECG strain (n=21) had more severe aortic stenosis, increased left ventricular mass index, more myocardial injury (high-sensitivity plasma cardiac troponin I concentration, 4.3 ng/L [interquartile range, 2.5-7.3 ng/L] versus 7.3 ng/L [interquartile range, 3.2-20.8 ng/L] versus 18.6 ng/L [interquartile range, 9.0-45.2 ng/L], respectively; P<0.001) and increased diffuse fibrosis (extracellular volume fraction, 27.4±2.2% versus 27.2±2.9% versus 30.9±1.9%, respectively; P<0.001). All patients with ECG strain had midwall late gadolinium enhancement (positive and negative predictive values of 100% and 86%, respectively). Indeed, late gadolinium enhancement was independently associated with ECG strain (odds ratio, 1.73; 95% confidence interval, 1.08-2.77; P=0.02), a finding confirmed in the validation cohort. In the outcome cohort, ECG strain was an independent predictor of aortic valve replacement or cardiovascular death (hazard ratio, 2.67; 95% confidence interval, 1.35-5.27; P<0.01). ECG strain is a specific marker of midwall myocardial fibrosis and predicts adverse clinical outcomes in aortic stenosis. © 2014 American Heart Association, Inc.
Understanding pave-IR : background, use, and advanced techniques
DOT National Transportation Integrated Search
2010-01-01
Why Has TxDOT Implemented Pave-IR? : Promote more uniform, higher quality pavements : Minimize/eliminate thermal segregation : Expand range of weather conditions for paving : Special Provision 341-024 : Contains option for contractor to use Pave-IR :...
Generation and multi-octave shaping of mid-infrared intense single-cycle pulses
NASA Astrophysics Data System (ADS)
Krogen, Peter; Suchowski, Haim; Liang, Houkun; Flemens, Noah; Hong, Kyung-Han; Kärtner, Franz X.; Moses, Jeffrey
2017-03-01
The generation of intense mid-infrared (mid-IR) optical pulses with customizable shape and spectra spanning a multiple-octave range of vibrational frequencies is an elusive technological capability. While some recent approaches to mid-IR supercontinuum generation—such as filamentation, multicolour four-wave-mixing and optical rectification—have successfully generated broad spectra, no process has been identified for achieving complex pulse shaping at the generation step. The adiabatic frequency converter allows for a one-to-one transfer of spectral phase through nonlinear frequency conversion over a larger-than-octave-spanning range and with an overall linear phase transfer function. Here, we show that we can convert shaped near-infrared (near-IR) pulses to shaped, energetic, multi-octave-spanning mid-IR pulses lasting only 1.2 optical cycles, and extendable to the sub-cycle regime. We expect this capability to enable a new class of precisely controlled nonlinear interactions in the mid-IR spectral range, from nonlinear vibrational spectroscopy to strong light-matter interactions and single-shot remote sensing.
Krishna, Sanjay [Albuquerque, NM; Hayat, Majeed M [Albuquerque, NM; Tyo, J Scott [Tucson, AZ; Jang, Woo-Yong [Albuquerque, NM
2011-12-06
Exemplary embodiments provide an infrared (IR) retinal system and method for making and using the IR retinal system. The IR retinal system can include adaptive sensor elements, whose properties including, e.g., spectral response, signal-to-noise ratio, polarization, or amplitude can be tailored at pixel level by changing the applied bias voltage across the detector. "Color" imagery can be obtained from the IR retinal system by using a single focal plane array. The IR sensor elements can be spectrally, spatially and temporally adaptive using quantum-confined transitions in nanoscale quantum dots. The IR sensor elements can be used as building blocks of an infrared retina, similar to cones of human retina, and can be designed to work in the long-wave infrared portion of the electromagnetic spectrum ranging from about 8 .mu.m to about 12 .mu.m as well as the mid-wave portion ranging from about 3 .mu.m to about 5 .mu.m.
Infrared imaging of subcutaneous veins.
Zharov, Vladimir P; Ferguson, Scott; Eidt, John F; Howard, Paul C; Fink, Louis M; Waner, Milton
2004-01-01
Imaging of subcutaneous veins is important in many applications, such as gaining venous access and vascular surgery. Despite a long history of medical infrared (IR) photography and imaging, this technique is not widely used for this purpose. Here we revisited and explored the capability of near-IR imaging to visualize subcutaneous structures, with a focus on diagnostics of superficial veins. An IR device comprising a head-mounted IR LED array (880 nm), a small conventional CCD camera (Toshiba Ik-mui, Tokyo, Japan), virtual-reality optics, polarizers, filters, and diffusers was used in vivo to obtain images of different subcutaneous structures. The same device was used to estimate the IR image quality as a function of wavelength produced by a tunable xenon lamp-based monochrometer in the range of 500-1,000 nm and continuous-wave Nd:YAG (1.06 microm) and diode (805 nm) lasers. The various modes of optical illumination were compared in vivo. Contrast of the IR images in the reflectance mode was measured in the near-IR spectral range of 650-1,060 nm. Using the LED array, various IR images were obtained in vivo, including images of vein structure in a pigmented, fatty forearm, varicose leg veins, and vascular lesions of the tongue. Imaging in the near-IR range (880-930 nm) provides relatively good contrast of subcutaneous veins, underscoring its value for diagnosis. This technique has the potential for the diagnosis of varicose veins with a diameter of 0.5-2 mm at a depth of 1-3 mm, guidance of venous access, podiatry, phlebotomy, injection sclerotherapy, and control of laser interstitial therapy. Copyright 2004 Wiley-Liss, Inc.
MIR and FIR Analysis of Inorganic Species in a Single Data Acquisition
NASA Astrophysics Data System (ADS)
Wang, Peng; Shilov, Sergey
2017-06-01
The extension of the mid IR towards the far IR spectral range below 400 \\wn is of great interest for molecular vibrational analysis for inorganic and organometallic chemistry, for geological, pharmaceutical, and physical applications, polymorph screening and crystallinity analysis as well as for matrix isolation spectroscopy. In these cases, the additional far infrared region offers insight to low energy vibrations which are observable only there. This includes inorganic species, lattice vibrations or intermolecular vibrations in the ordered solid state. The spectral range of a FTIR spectrometer is defined by the major optical components such as the source, beamsplitter, and detector. The globar source covers a broad spectral range from 8000 to 20 \\wn. However a bottle neck exists with respect to the beamsplitter and detector. To extend the spectral range further into the far IR and THz spectral ranges, one or more additional far IR beam splitters and detectors have been previously required. Two new optic components have been incorporated in a spectrometer to achieve coverage of both the mid and far infrared in a single scan: a wide range MIR-FIR beam splitter and the wide range DLaTGS detector that utilizes a diamond window. The use of a standard SiC IR source with these components yields a spectral range of 6000 down to 50 \\wn in one step for all types of transmittance, reflectance and ATR measurements. Utilizing the external water cooled mercury arc high power lamp the spectral range can be ultimately extended down to 10 \\wn. Examples of application will include emission in MIR-THz range, identification of pigments, additives in polymers, and polymorphism studies.
DDT-based indoor residual spraying suboptimal for visceral leishmaniasis elimination in India
Coleman, Michael; Foster, Geraldine M.; Deb, Rinki; Pratap Singh, Rudra; Ismail, Hanafy M.; Shivam, Pushkar; Ghosh, Ayan Kumar; Dunkley, Sophie; Kumar, Vijay; Coleman, Marlize; Hemingway, Janet; Paine, Mark J. I.; Das, Pradeep
2015-01-01
Indoor residual spraying (IRS) is used to control visceral leishmaniasis (VL) in India, but it is poorly quality assured. Quality assurance was performed in eight VL endemic districts in Bihar State, India, in 2014. Residual dichlorodiphenyltrichloroethane (DDT) was sampled from walls using Bostik tape discs, and DDT concentrations [grams of active ingredient per square meter (g ai/m2)] were determined using HPLC. Pre-IRS surveys were performed in three districts, and post-IRS surveys were performed in eight districts. A 20% threshold above and below the target spray of 1.0 g ai/m2 was defined as “in range.” The entomological assessments were made in four districts in IRS and non-IRS villages. Vector densities were measured: pre-IRS and 1 and 3 mo post-IRS. Insecticide susceptibility to 4% DDT and 0.05% deltamethrin WHO-impregnated papers was determined with wild-caught sand flies. The majority (329 of 360, 91.3%) of pre-IRS samples had residual DDT concentrations of <0.1 g ai/m2. The mean residual concentration of DDT post-IRS was 0.37 g ai/m2; 84.9% of walls were undersprayed, 7.4% were sprayed in range, and 7.6% were oversprayed. The abundance of sand flies in IRS and non-IRS villages was significantly different at 1 mo post-IRS only. Sand flies were highly resistant to DDT but susceptible to deltamethrin. The Stockholm Convention, ratified by India in 2006, calls for the complete phasing out of DDT as soon as practical, with limited use in the interim where no viable IRS alternatives exist. Given the poor quality of the DDT-based IRS, ready availability of pyrethroids, and susceptibility profile of Indian sand flies, the continued use of DDT in this IRS program is questionable. PMID:26124110
DDT-based indoor residual spraying suboptimal for visceral leishmaniasis elimination in India.
Coleman, Michael; Foster, Geraldine M; Deb, Rinki; Pratap Singh, Rudra; Ismail, Hanafy M; Shivam, Pushkar; Ghosh, Ayan Kumar; Dunkley, Sophie; Kumar, Vijay; Coleman, Marlize; Hemingway, Janet; Paine, Mark J I; Das, Pradeep
2015-07-14
Indoor residual spraying (IRS) is used to control visceral leishmaniasis (VL) in India, but it is poorly quality assured. Quality assurance was performed in eight VL endemic districts in Bihar State, India, in 2014. Residual dichlorodiphenyltrichloroethane (DDT) was sampled from walls using Bostik tape discs, and DDT concentrations [grams of active ingredient per square meter (g ai/m(2))] were determined using HPLC. Pre-IRS surveys were performed in three districts, and post-IRS surveys were performed in eight districts. A 20% threshold above and below the target spray of 1.0 g ai/m(2) was defined as "in range." The entomological assessments were made in four districts in IRS and non-IRS villages. Vector densities were measured: pre-IRS and 1 and 3 mo post-IRS. Insecticide susceptibility to 4% DDT and 0.05% deltamethrin WHO-impregnated papers was determined with wild-caught sand flies. The majority (329 of 360, 91.3%) of pre-IRS samples had residual DDT concentrations of <0.1 g ai/m(2). The mean residual concentration of DDT post-IRS was 0.37 g ai/m(2); 84.9% of walls were undersprayed, 7.4% were sprayed in range, and 7.6% were oversprayed. The abundance of sand flies in IRS and non-IRS villages was significantly different at 1 mo post-IRS only. Sand flies were highly resistant to DDT but susceptible to deltamethrin. The Stockholm Convention, ratified by India in 2006, calls for the complete phasing out of DDT as soon as practical, with limited use in the interim where no viable IRS alternatives exist. Given the poor quality of the DDT-based IRS, ready availability of pyrethroids, and susceptibility profile of Indian sand flies, the continued use of DDT in this IRS program is questionable.
Oxadiazole-carbazole polymer (POC)-Ir(ppy)3 tunable emitting composites
NASA Astrophysics Data System (ADS)
Bruno, Annalisa; Borriello, Carmela; Di Luccio, Tiziana; Sessa, Lucia; Concilio, Simona; Haque, Saif A.; Minarini, Carla
2017-04-01
POC polymer is an oxadiazole-carbazole copolymer we have previously synthetized and established as light emitting material in Organic Light Emitting Devices (OLEDs), although POC quantum yield emission efficiency and color purity still need to be enhanced. On the other hand, tris[2-phenylpyridinato-C2,N]iridium(III) (Ir(ppy)3) complexes, namely Ir(ppy)3 are among the brightest luminophores employed in green light emitting devices. Our aim, in this work, is to take advantage of Ir(ppy)3 bright emission by combining the Ir complex with blue emitting POC to obtain tunable light emitting composites over a wide range of the visible spectrum. Here we have investigated the optical proprieties POC based nanocomposites with different concentrations of Ir(ppy)3, ranging from 1 to 10 wt%. Both spectral and time resolved fluorescence measurements show an efficient energy transfer from the polymer to the dopants, resulting in white-emitting composites. The most intense and stable emission has been found when POC was doped with about 5 wt% concentration of Ir(ppy)3.
Tóth, Gábor; Sándor, Gábor László; Kleiner, Dénes; Szentmáry, Nóra; Kiss, Huba J; Blázovics, Anna; Nagy, Zoltán Zsolt
2016-11-01
Femtosecond laser is a revolutionary, innovative treatment method used in cataract surgery. To evaluate free radical quantity in the anterior chamber of the eye, during femtosecond laser assisted capsulotomy, in a porcine eye model. Seventy fresh porcine eyes were collected within 2 hours post mortem, were transported at 4 ºC and treated within 7 hours. Thirty-five eyes were used as control and 35 as femtosecond laser assisted capsulotomy group. A simple luminol-dependent chemiluminescence method was used to measure the total scavenger capacity in the aqueous humour, as an indicator of free radical production. The emitted photons were expressed in relative light unit %. The relative light unit % was lower in the control group (median 1%, interquartile range [0.4-3%]) than in the femtosecond laser assisted capsulotomy group (median 4.4%, interquartile range [1.5%-21%]) (p = 0.01). Femtosecond laser assisted capsulotomy decreases the antioxidant defense of the anterior chamber, which refers to a significant free radical production during femtosecond laser assisted capsulotomy. Orv. Hetil., 2016, 157(47), 1880-1883.
Higher sweat chloride levels in patients with asthma: a case-control study.
Awasthi, Shally; Dixit, Pratibha; Maurya, Nutan
2015-02-01
To screen asthmatic patients by sweat chloride test to identify proportion with Cystic Fibrosis (CF); (Sweat chloride level >60 mmol/L). Also, to compare sweat chloride levels between cases of bronchial asthma and age and sex matched healthy children aged 5 mo-15 y. The present case-control study was conducted in a tertiary care hospital in India. Cases of bronchial asthma, diagnosed by GINA guideline 2008, and age matched healthy controls were included. Case to control ratio was 2:1. Sweat Chloride test was done by Pilocarpine Iontophoresis method. From April 2010 through May 2012, 216 asthmatics and 112 controls were recruited. Among asthmatics, there was no case of Cystic Fibrosis. Mean sweat chloride levels in asthmatics was 22.39 ± 8.45 mmol/L (inter-quartile range - 15-28 mmol/L) and in controls 19.55 ± 7.04 mmol/L (inter-quartile range - 15-23.5 mmol/L) (p value = 0.048). No Cystic Fibrosis case was identified among asthmatics. Mean sweat chloride levels were higher in asthmatics as compared to controls.
Changing Epidemiology of Human Brucellosis, China, 1955–2014
Lai, Shengjie; Zhou, Hang; Xiong, Weiyi; Gilbert, Marius; Huang, Zhuojie; Yu, Jianxing; Yin, Wenwu; Wang, Liping; Chen, Qiulan; Li, Yu; Mu, Di; Zeng, Lingjia; Ren, Xiang; Geng, Mengjie; Zhang, Zike; Cui, Buyun; Li, Tiefeng; Wang, Dali; Li, Zhongjie; Wardrop, Nicola A.; Tatem, Andrew J.
2017-01-01
Brucellosis, a zoonotic disease, was made statutorily notifiable in China in 1955. We analyzed the incidence and spatial–temporal distribution of human brucellosis during 1955–2014 in China using notifiable surveillance data: aggregated data for 1955–2003 and individual case data for 2004–2014. A total of 513,034 brucellosis cases were recorded, of which 99.3% were reported in northern China during 1955–2014, and 69.1% (258, 462/374, 141) occurred during February–July in 1990–2014. Incidence remained high during 1955–1978 (interquartile range 0.42–1.0 cases/100,000 residents), then decreased dramatically in 1979–1994. However, brucellosis has reemerged since 1995 (interquartile range 0.11–0.23 in 1995–2003 and 1.48–2.89 in 2004–2014); the historical high occurred in 2014, and the affected area expanded from northern pastureland provinces to the adjacent grassland and agricultural areas, then to southern coastal and southwestern areas. Control strategies in China should be adjusted to account for these changes by adopting a One Health approach. PMID:28098531
Androgenic correlates of genetic variation in the gene encoding 5alpha-reductase type 1.
Ellis, Justine A; Panagiotopoulos, Sianna; Akdeniz, Aysel; Jerums, George; Harrap, Stephen B
2005-01-01
Androgens determine male secondary sexual characteristics and influence a variety of metabolic pathways. Circulating levels of androgens are highly heritable; however, the genes involved are largely unknown. The 5alpha-reductase enzymes types 1 and 2 responsible for converting testosterone to the more potent androgen dihydrotestosterone are encoded by the SRD5A1 and SRD5A2 genes, respectively. We performed indirect genetic association studies of SRD5A1 and SRD5A2 and the dihydrotestosterone/testosterone ratio that reflects the activity of 5alpha-reductase in 57 males with type 2 diabetes. We found evidence of significant association between a single nucleotide polymorphism in SRD5A1 and the dihydrotestosterone/testosterone ratio (median 0.10, interquartile range 0.08 vs. median 0.06, interquartile range 0.04, P = 0.009). The polymorphism was not associated with any diabetic phenotypes. These results suggest that functional genetic variants might exist in or around SRD5A1 that affect the activity of the 5alpha-reductase enzyme type 1 and influence androgen levels.
Göktay, Fatih; Altan, Zeynep Müzeyyen; Talas, Anıl; Akpınar, Esma; Özdemir, Ekin Özge; Aytekin, Sema
2016-01-01
Patient anxiety about nail surgery relates mainly to pain associated with needle puncture, anesthetic flow during the procedure, and postoperative care, as well as possible past traumatic experience. The aims of this study were to compare anxiety levels among patients undergoing nail surgery and skin punch biopsy and to assess the effects of demographic characteristics on anxiety. Forty-eight consecutive patients who were referred to a dermatological surgery unit for nail surgery intervention (group 1) and 50 age- and sex-matched patients referred to the same unit for skin punch biopsy (group 2) were enrolled in the study. Patients' anxiety levels were measured using Spielberger's State-Trait Anxiety Inventory. There was no significant difference in median anxiety level between group 1 (42.00; interquartile range, 6.50) and group 2 (41.00; interquartile range, 8.25) (P = .517). The demographic factors of patient sex, educational status, and prior surgery showed no significant effects on anxiety levels. Nail surgery does not seem to cause significantly greater anxiety than skin punch biopsy. © The Author(s) 2015.
Rathi, Vinay K; Wang, Bo; Ross, Joseph S; Downing, Nicholas S; Kesselheim, Aaron S; Gray, Stacey T
2017-02-01
The US Food and Drug Administration (FDA) approves high-risk medical devices based on premarket pivotal clinical studies demonstrating reasonable assurance of safety and effectiveness and may require postapproval studies (PAS) to further inform benefit-risk assessment. We conducted a cross-sectional analysis using publicly available FDA documents to characterize industry-sponsored pivotal studies and PAS of high-risk devices used in the treatment of otolaryngologic diseases. Between 2000 and 2014, the FDA approved 23 high-risk otolaryngologic devices based on 28 pivotal studies. Median enrollment was 118 patients (interquartile range, 67-181), and median duration of longest primary effectiveness end point follow-up was 26 weeks (interquartile range, 16-96). Fewer than half were randomized (n = 13, 46%), blinded (n = 12, 43%), or controlled (n = 10, 36%). The FDA required 23 PASs for 16 devices (70%): almost two-thirds (n = 15, 65%) monitored long-term performance, and roughly one-third (n = 8, 35%) focused on subgroups. Otolaryngologists should be aware of limitations in the strength of premarket evidence when considering the use of newly approved devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penner, Kyle; Dickinson, Mark; Dey, Arjun
Dusty galaxies at z {approx} 2 span a wide range of relative brightness between rest-frame mid-infrared (8 {mu}m) and ultraviolet wavelengths. We attempt to determine the physical mechanism responsible for this diversity. Dust-obscured galaxies (DOGs), which have rest-frame mid-IR to UV flux density ratios {approx}> 1000, might be abnormally bright in the mid-IR, perhaps due to prominent emission from active galactic nuclei and/or polycyclic aromatic hydrocarbons, or abnormally faint in the UV. We use far-infrared data from the GOODS-Herschel survey to show that most DOGs with 10{sup 12} L {sub Sun} {approx}< L {sub IR} {approx}< 10{sup 13} L {submore » Sun} are not abnormally bright in the mid-IR when compared to other dusty galaxies with similar IR (8-1000 {mu}m) luminosities. We observe a relation between the median IR to UV luminosity ratios and the median UV continuum power-law indices for these galaxies, and we find that only 24% have specific star formation rates that indicate the dominance of compact star-forming regions. This circumstantial evidence supports the idea that the UV- and IR-emitting regions in these galaxies are spatially coincident, which implies a connection between the abnormal UV faintness of DOGs and dust obscuration. We conclude that the range in rest-frame mid-IR to UV flux density ratios spanned by dusty galaxies at z {approx} 2 is due to differing amounts of UV obscuration. Of galaxies with these IR luminosities, DOGs are the most obscured. We attribute differences in UV obscuration to either (1) differences in the degree of alignment between the spatial distributions of dust and massive stars or (2) differences in the total dust content.« less
False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria
Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.
2015-01-01
Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values <1.5 mg/dl (P<0.001). Conclusions Use of small serum creatinine changes to diagnose AKI is limited by high false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID:26336912
False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.
Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry
2015-10-07
Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values <1.5 mg/dl (P<0.001). Use of small serum creatinine changes to diagnose AKI is limited by high false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.
Finn Davis, Katherine; Napolitano, Natalie; Li, Simon; Buffman, Hayley; Rehder, Kyle; Pinto, Matthew; Nett, Sholeen; Jarvis, J Dean; Kamat, Pradip; Sanders, Ronald C; Turner, David A; Sullivan, Janice E; Bysani, Kris; Lee, Anthony; Parker, Margaret; Adu-Darko, Michelle; Giuliano, John; Biagas, Katherine; Nadkarni, Vinay; Nishisaki, Akira
2017-10-01
To describe promoters and barriers to implementation of an airway safety quality improvement bundle from the perspective of interdisciplinary frontline clinicians and ICU quality improvement leaders. Mixed methods. Thirteen PICUs of the National Emergency Airway Registry for Children network. Remote or on-site focus groups with interdisciplinary ICU staff. Two semistructured interviews with ICU quality improvement leaders with quantitative and qualitative data-based feedbacks. Bundle implementation success (compliance) was defined as greater than or equal to 80% use for tracheal intubations for 3 consecutive months. ICUs were classified as early or late adopters. Focus group discussions concentrated on safety concerns and promoters and barriers to bundle implementation. Initial semistructured quality improvement leader interviews assessed implementation tactics and provided recommendations. Follow-up interviews assessed degree of acceptance and changes made after initial interview. Transcripts were thematically analyzed and contrasted by early versus late adopters. Median duration to achieve success was 502 days (interquartile range, 182-781). Five sites were early (median, 153 d; interquartile range, 146-267) and eight sites were late adopters (median, 783 d; interquartile range, 773-845). Focus groups identified common "promoter" themes-interdisciplinary approach, influential champions, and quality improvement bundle customization-and "barrier" themes-time constraints, competing paperwork and quality improvement activities, and poor engagement. Semistructured interviews with quality improvement leaders identified effective and ineffective tactics implemented by early and late adopters. Effective tactics included interdisciplinary quality improvement team involvement (early adopter: 5/5, 100% vs late adopter: 3/8, 38%; p = 0.08); ineffective tactics included physician-only rollouts, lack of interdisciplinary education, lack of data feedback to frontline clinicians, and misconception of bundle as research instead of quality improvement intervention. Implementation of an airway safety quality improvement bundle with high compliance takes a long time across diverse ICUs. Both early and late adopters identified similar promoter and barrier themes. Early adopter sites customized the quality improvement bundle and had an interdisciplinary quality improvement team approach.
Kim, Joon-Tae; Chung, Pil-Wook; Starkman, Sidney; Sanossian, Nerses; Stratton, Samuel J; Eckstein, Marc; Pratt, Frank D; Conwit, Robin; Liebeskind, David S; Sharma, Latisha; Restrepo, Lucas; Tenser, May-Kim; Valdes-Sueiras, Miguel; Gornbein, Jeffrey; Hamilton, Scott; Saver, Jeffrey L
2017-02-01
The Los Angeles Motor Scale (LAMS) is a 3-item, 0- to 10-point motor stroke-deficit scale developed for prehospital use. We assessed the convergent, divergent, and predictive validity of the LAMS when performed by paramedics in the field at multiple sites in a large and diverse geographic region. We analyzed early assessment and outcome data prospectively gathered in the FAST-MAG trial (Field Administration of Stroke Therapy-Magnesium phase 3) among patients with acute cerebrovascular disease (cerebral ischemia and intracranial hemorrhage) within 2 hours of onset, transported by 315 ambulances to 60 receiving hospitals. Among 1632 acute cerebrovascular disease patients (age 70±13 years, male 57.5%), time from onset to prehospital LAMS was median 30 minutes (interquartile range 20-50), onset to early postarrival (EPA) LAMS was 145 minutes (interquartile range 119-180), and onset to EPA National Institutes of Health Stroke Scale was 150 minutes (interquartile range 120-180). Between the prehospital and EPA assessments, LAMS scores were stable in 40.5%, improved in 37.6%, and worsened in 21.9%. In tests of convergent validity, against the EPA National Institutes of Health Stroke Scale, correlations were r=0.49 for the prehospital LAMS and r=0.89 for the EPA LAMS. Prehospital LAMS scores did diverge from the prehospital Glasgow Coma Scale, r=-0.22. Predictive accuracy (adjusted C statistics) for nondisabled 3-month outcome was as follows: prehospital LAMS, 0.76 (95% confidence interval 0.74-0.78); EPA LAMS, 0.85 (95% confidence interval 0.83-0.87); and EPA National Institutes of Health Stroke Scale, 0.87 (95% confidence interval 0.85-0.88). In this multicenter, prospective, prehospital study, the LAMS showed good to excellent convergent, divergent, and predictive validity, further establishing it as a validated instrument to characterize stroke severity in the field. © 2017 American Heart Association, Inc.
2011-01-01
Introduction The role of ICU design and particularly single-patient rooms in decreasing bacterial transmission between ICU patients has been debated. A recent change in our ICU allowed further investigation. Methods Pre-move ICU-A and pre-move ICU-B were open-plan units. In March 2007, ICU-A moved to single-patient rooms (post-move ICU-A). ICU-B remained unchanged (post-move ICU-B). The same physicians cover both ICUs. Cultures of specified resistant organisms in surveillance or clinical cultures from consecutive patients staying >48 hours were compared for the different ICUs and periods to assess the effect of ICU design on acquisition of resistant organisms. Results Data were collected for 62, 62, 44 and 39 patients from pre-move ICU-A, post-move ICU-A, pre-move ICU-B and post-move ICU-B, respectively. Fewer post-move ICU-A patients acquired resistant organisms (3/62, 5%) compared with post-move ICU-B patients (7/39, 18%; P = 0.043, P = 0.011 using survival analysis) or pre-move ICU-A patients (14/62, 23%; P = 0.004, P = 0.012 on survival analysis). Only the admission period was significant for acquisition of resistant organisms comparing pre-move ICU-A with post-move ICU-A (hazard ratio = 5.18, 95% confidence interval = 1.03 to 16.06; P = 0.025). More antibiotic-free days were recorded in post-move ICU-A (median = 3, interquartile range = 0 to 5) versus post-move ICU-B (median = 0, interquartile range = 0 to 4; P = 0.070) or pre-move ICU-A (median = 0, interquartile range = 0 to 4; P = 0.017). Adequate hand hygiene was observed on 140/242 (58%) occasions in post-move ICU-A versus 23/66 (35%) occasions in post-move ICU-B (P < 0.001). Conclusions Improved ICU design, and particularly use of single-patient rooms, decreases acquisition of resistant bacteria and antibiotic use. This observation should be considered in future ICU design. PMID:21914222
Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes.
Murphy, Helen R; Elleri, Daniela; Allen, Janet M; Harris, Julie; Simmons, David; Rayman, Gerry; Temple, Rosemary; Dunger, David B; Haidar, Ahmad; Nodale, Marianna; Wilinska, Malgorzata E; Hovorka, Roman
2011-02-01
This study evaluated closed-loop insulin delivery with a model predictive control (MPC) algorithm during early (12-16 weeks) and late gestation (28-32 weeks) in pregnant women with type 1 diabetes. Ten women with type 1 diabetes (age 31 years, diabetes duration 19 years, BMI 24.1 kg/m(2), booking A1C 6.9%) were studied over 24 h during early (14.8 weeks) and late pregnancy (28.0 weeks). A nurse adjusted the basal insulin infusion rate from continuous glucose measurements (CGM), fed into the MPC algorithm every 15 min. Mean glucose and time spent in target (63-140 mg/dL), hyperglycemic (>140 to ≥ 180 mg/dL), and hypoglycemic (<63 to ≤ 50 mg/dL) were calculated using plasma and sensor glucose measurements. Linear mixed-effects models were used to compare glucose control during early and late gestation. During closed-loop insulin delivery, median (interquartile range) plasma glucose levels were 117 (100.8-154.8) mg/dL in early and 126 (109.8-140.4) mg/dL in late gestation (P = 0.72). The overnight mean (interquartile range) plasma glucose time in target was 84% (50-100%) in early and 100% (94-100%) in late pregnancy (P = 0.09). Overnight mean (interquartile range) time spent hyperglycemic (>140 mg/dL) was 7% (0-40%) in early and 0% (0-6%) in late pregnancy (P = 0.25) and hypoglycemic (<63 mg/dL) was 0% (0-3%) and 0% (0-0%), respectively (P = 0.18). Postprandial glucose control, glucose variability, insulin infusion rates, and CGM sensor accuracy were no different in early or late pregnancy. MPC algorithm performance was maintained throughout pregnancy, suggesting that overnight closed-loop insulin delivery could be used safely during pregnancy. More work is needed to achieve optimal postprandial glucose control.
Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes
Murphy, Helen R.; Elleri, Daniela; Allen, Janet M.; Harris, Julie; Simmons, David; Rayman, Gerry; Temple, Rosemary; Dunger, David B.; Haidar, Ahmad; Nodale, Marianna; Wilinska, Malgorzata E.; Hovorka, Roman
2011-01-01
OBJECTIVE This study evaluated closed-loop insulin delivery with a model predictive control (MPC) algorithm during early (12–16 weeks) and late gestation (28–32 weeks) in pregnant women with type 1 diabetes. RESEARCH DESIGN AND METHODS Ten women with type 1 diabetes (age 31 years, diabetes duration 19 years, BMI 24.1 kg/m2, booking A1C 6.9%) were studied over 24 h during early (14.8 weeks) and late pregnancy (28.0 weeks). A nurse adjusted the basal insulin infusion rate from continuous glucose measurements (CGM), fed into the MPC algorithm every 15 min. Mean glucose and time spent in target (63–140 mg/dL), hyperglycemic (>140 to ≥180 mg/dL), and hypoglycemic (<63 to ≤50 mg/dL) were calculated using plasma and sensor glucose measurements. Linear mixed-effects models were used to compare glucose control during early and late gestation. RESULTS During closed-loop insulin delivery, median (interquartile range) plasma glucose levels were 117 (100.8–154.8) mg/dL in early and 126 (109.8–140.4) mg/dL in late gestation (P = 0.72). The overnight mean (interquartile range) plasma glucose time in target was 84% (50–100%) in early and 100% (94–100%) in late pregnancy (P = 0.09). Overnight mean (interquartile range) time spent hyperglycemic (>140 mg/dL) was 7% (0–40%) in early and 0% (0–6%) in late pregnancy (P = 0.25) and hypoglycemic (<63 mg/dL) was 0% (0–3%) and 0% (0–0%), respectively (P = 0.18). Postprandial glucose control, glucose variability, insulin infusion rates, and CGM sensor accuracy were no different in early or late pregnancy. CONCLUSIONS MPC algorithm performance was maintained throughout pregnancy, suggesting that overnight closed-loop insulin delivery could be used safely during pregnancy. More work is needed to achieve optimal postprandial glucose control. PMID:21216859
Chen, J; Li, Y; Wang, Z; McCulloch, P; Hu, L; Chen, W; Liu, G; Li, J; Lang, J
2018-02-01
To evaluate the clinical outcomes of high-intensity focused ultrasound (HIFU) and surgery in treating uterine fibroids, and prepare for a definitive randomised trial. Prospective multicentre patient choice cohort study (IDEAL Exploratory study) of HIFU, myomectomy or hysterectomy for treating symptomatic uterine fibroids. 20 Chinese hospitals. 2411 Chinese women with symptomatic fibroids. Prospective non-randomised cohort study with learning curve analysis (IDEAL Stage 2b Prospective Exploration Study). Complications, hospital stay, return to normal activities, and quality of life (measured with UFS-Qol and SF-36 at baseline, 6 and 12 months), and need for further treatment. Quality-of-life outcomes were adjusted using regression modelling. HIFU treatment quality was evaluated using LC-CUSUM to identify operator learning curves. A health economic analysis of costs was performed. 1353 women received HIFU, 472 hysterectomy and 586 myomectomy. HIFU patients were significantly younger (P < 0.001), slimmer (P < 0.001), better educated (P < 0.001), and wealthier (P = 0.002) than surgery patients. Both UFS and QoL improved more rapidly after HIFU than after surgery (P = 0.002 and P = 0.001, respectively at 6 months), but absolute differences were small. Major adverse events occurred in 3 (0.2%) of HIFU and in 133 (12.6%) of surgical cases (P < 0.001). Median time for hospital stay was 4 days (interquartile range, 0-5 days), 10 days (interquartile range, 8-12.5 days) and 8 days (interquartile range, 7-10 days). HIFU caused substantially less morbidity than surgery, with similar longer-term QoL. Despite group baseline differences and lack of blinding, these findings support the need for a randomised controlled trial (RCT) of HIFU treatment for fibroids. The IDEAL Exploratory design facilitated RCT protocol development. HIFU had much better short-term outcomes than surgery for fibroids in 2411-patient Chinese IDEAL format study. © 2017 Royal College of Obstetricians and Gynaecologists.
Hubert, Gordian J; Meretoja, Atte; Audebert, Heinrich J; Tatlisumak, Turgut; Zeman, Florian; Boy, Sandra; Haberl, Roman L; Kaste, Markku; Müller-Barna, Peter
2016-12-01
Intravenous thrombolysis with tissue-type plasminogen activator (tPA) for acute ischemic stroke is more effective when delivered early. Timely delivery is challenging particularly in rural areas with long distances. We compared delays and treatment rates of a large, decentralized telemedicine-based system and a well-organized, large, centralized single-hospital system. We analyzed the centralized system of the Helsinki University Central Hospital (Helsinki and Province of Uusimaa, Finland, 1.56 million inhabitants, 9096 km 2 ) and the decentralized TeleStroke Unit network in a predominantly rural area (Telemedical Project for Integrative Stroke Care [TEMPiS], South-East Bavaria, Germany, 1.94 million inhabitants, 14 992 km 2 ). All consecutive tPA treatments were prospectively registered. We compared tPA rates per total ischemic stroke admissions in the Helsinki and TEMPiS catchment areas. For delay comparisons, we excluded patients with basilar artery occlusions, in-hospital strokes, and those being treated after 270 minutes. From January 1, 2011, to December 31, 2013, 912 patients received tPA in Helsinki University Central Hospital and 1779 in TEMPiS hospitals. Area-based tPA rates were equal (13.0% of 7017 ischemic strokes in the Helsinki University Central Hospital area versus 13.3% of 14 637 ischemic strokes in the TEMPiS area; P=0.078). Median prehospital delays were longer (88; interquartile range, 60-135 versus 65; 48-101 minutes; P<0.001) but in-hospital delays were shorter (18; interquartile range, 13-30 versus 39; 26-56 minutes; P<0.001) in Helsinki University Central Hospital compared with TEMPiS with no difference in overall delays (117; interquartile range, 81-168 versus 115; 87-155 minutes; P=0.45). A decentralized telestroke thrombolysis service can achieve similar treatment rates and time delays for a rural population as a centralized system can achieve for an urban population. © 2016 American Heart Association, Inc.
Geographic Variance of Cost Associated With Hysterectomy.
Sheyn, David; Mahajan, Sangeeta; Billow, Megan; Fleary, Alexandra; Hayashi, Emi; El-Nashar, Sherif A
2017-05-01
To estimate whether the cost of hysterectomy varies by geographic region. This was a cross-sectional, population-based study using the 2013 Healthcare Cost and Utilization Project National Inpatient Sample of women older than 18 years undergoing inpatient hysterectomy for benign conditions. Hospital charges obtained from the National Inpatient Sample database were converted to actual costs using cost-to-charge ratios provided by the Healthcare Cost and Utilization Project. Multivariate regression was used to assess the effects that demographic factors, concomitant procedures, diagnoses, and geographic region have on hysterectomy cost above the median. Women who underwent hysterectomy for benign conditions were identified (N=38,414). The median cost of hysterectomy was $13,981 (interquartile range $9,075-29,770). The mid-Atlantic region had the lowest median cost of $9,661 (interquartile range $6,243-15,335) and the Pacific region had the highest median cost, $22,534 (interquartile range $15,380-33,797). Compared with the mid-Atlantic region, the Pacific (adjusted odds ratio [OR] 10.43, 95% confidence interval [CI] 9.44-11.45), South Atlantic (adjusted OR 5.39, 95% CI 4.95-5.86), and South Central (adjusted OR 2.40, 95% CI 2.21-2.62) regions were associated with the highest probability of costs above the median. All concomitant procedures were associated with an increased cost with the exception of bilateral salpingectomy (adjusted OR 1.03, 95% CI 0.95-1.12). Compared with vaginal hysterectomy, laparoscopic and robotic modes of hysterectomy were associated with higher probabilities of increased costs (adjusted OR 2.86, 95% CI 2.61-3.15 and adjusted OR 5.66, 95% CI 5.11-6.26, respectively). Abdominal hysterectomy was not associated with a statistically significant increase in cost compared with vaginal hysterectomy (adjusted OR 1.01, 95% CI 0.91-1.09). The cost of hysterectomy varies significantly with geographic region after adjusting for confounders.
Goei, Dustin; van Kuijk, Jan-Peter; Flu, Willem-Jan; Hoeks, Sanne E; Chonchol, Michel; Verhagen, Hence J M; Bax, Jeroen J; Poldermans, Don
2011-02-15
Plasma N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) levels improve preoperative cardiac risk stratification in vascular surgery patients. However, single preoperative measurements of NT-pro-BNP cannot take into account the hemodynamic stress caused by anesthesia and surgery. Therefore, the aim of the present study was to assess the incremental predictive value of changes in NT-pro-BNP during the perioperative period for long-term cardiac mortality. Detailed cardiac histories, rest left ventricular echocardiography, and NT-pro-BNP levels were obtained in 144 patients before vascular surgery and before discharge. The study end point was the occurrence of cardiovascular death during a median follow-up period of 13 months (interquartile range 5 to 20). Preoperatively, the median NT-pro-BNP level in the study population was 314 pg/ml (interquartile range 136 to 1,351), which increased to a median level of 1,505 pg/ml (interquartile range 404 to 6,453) before discharge. During the follow-up period, 29 patients (20%) died, 27 (93%) from cardiovascular causes. The median difference in NT-pro-BNP in the survivors was 665 pg/ml, compared to 5,336 pg/ml in the patients who died (p = 0.01). Multivariate Cox regression analyses, adjusted for cardiac history and cardiovascular risk factors (age, angina pectoris, myocardial infarction, stroke, diabetes mellitus, renal dysfunction, body mass index, type of surgery and the left ventricular ejection fraction), demonstrated that the difference in NT-pro-BNP level between pre- and postoperative measurement was the strongest independent predictor of cardiac outcome (hazard ratio 3.06, 95% confidence interval 1.36 to 6.91). In conclusion, the change in NT-pro-BNP, indicated by repeated measurements before surgery and before discharge is the strongest predictor of cardiac outcomes in patients who undergo vascular surgery. Copyright © 2011 Elsevier Inc. All rights reserved.
A Review of Online Evidence-based Practice Point-of-Care Information Summary Providers
Liberati, Alessandro; Moschetti, Ivan; Tagliabue, Ludovica; Moja, Lorenzo
2010-01-01
Background Busy clinicians need easy access to evidence-based information to inform their clinical practice. Publishers and organizations have designed specific tools to meet doctors’ needs at the point of care. Objective The aim of this study was to describe online point-of-care summaries and evaluate their breadth, content development, and editorial policy against their claims of being “evidence-based.” Methods We searched Medline, Google, librarian association websites, and information conference proceedings from January to December 2008. We included English Web-based point-of-care summaries designed to deliver predigested, rapidly accessible, comprehensive, periodically updated, evidence-based information to clinicians. Two investigators independently extracted data on the general characteristics and content presentation of summaries. We assessed and ranked point-of-care products according to: (1) coverage (volume) of medical conditions, (2) editorial quality, and (3) evidence-based methodology. We explored how these factors were associated. Results We retrieved 30 eligible summaries. Of these products, 18 met our inclusion criteria and were qualitatively described, and 16 provided sufficient data for quantitative evaluation. The median volume of medical conditions covered was 80.6% (interquartile range, 68.9% - 84.2%) and varied for the different products. Similarly, differences emerged for editorial policy (median 8.0, interquartile range 5.8 - 10.3) and evidence-based methodology scores (median 10.0, interquartile range 1.0 - 12.8) on a 15-point scale. None of these dimensions turned out to be significantly associated with the other dimensions (editorial quality and volume, Spearman rank correlation r = -0.001, P = .99; evidence-based methodology and volume, r = -0.19, P = .48; editorial and evidence-based methodology, r = 0.43, P =.09). Conclusions Publishers are moving to develop point-of-care summary products. Some of these have better profiles than others, and there is room for improved reporting of the strengths and weaknesses of these products. PMID:20610379
Gurvitch, R; Wood, D A; Tay, E L; Leipsic, J; Ye, J; Lichtenstein, S V; Thompson, C R; Carere, R G; Wijesinghe, N; Nietlispach, F; Boone, R H; Lauck, S; Cheung, A; Webb, J G
2010-09-28
Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.
Roca, Bernardino; Mendoza, María A; Roca, Manuel
2016-10-01
To compare the efficacy of extracorporeal shock wave therapy (ESWT) with botulinum toxin type A (BoNT-A) in the treatment of plantar fasciitis (PF). Open label, prospective, randomized study. A total of 72 patients were included. In all participants the median (and interquartile range) of the visual analog scale (VAS) of pain result, when taking the first steps, was 8 (6-9) points before treatment and 6 (4-8) points after treatment (p < 0.001). In the group of patients that received ESWT, the median (and interquartile range) of improvement in the VAS of pain result, when taking the first steps, was 2 (1-4) points, and in the group of patients that received BoNT-A the same result was 1 (0-2) points (p = 0.009). In the group of patients that received ESWT, the median (and interquartile range) of improvement in the Roles and Maudsley scale of pain result was 1 (0-1) points, and in the group of patients that received BoNT-A the same result was 0 (0-1) points (p = 0.006). In a multivariate analysis use of ESWT and lower weight were associated with improvement of pain with treatment in at least one of the three VAS of pain scales used in the study. ESWT was superior to BoNT-A in the control of pain in patients with PF. Implications for Rehabilitation Plantar fasciitis is characterized by pain at the calcaneal origin of the plantar fascia, exacerbated by weight bearing after prolonged periods of rest. Although studies comparing extracorporeal shock wave therapy or botulinum toxin type A to placebo suggest a superiority of the first one, no reliable data exist about it. Extracorporeal shock wave therapy was superior to botulinum toxin type A in the control of pain in patients with PF.
Antimalarial Activity of KAF156 in Falciparum and Vivax Malaria.
White, Nicholas J; Duong, Tran T; Uthaisin, Chirapong; Nosten, François; Phyo, Aung P; Hanboonkunupakarn, Borimas; Pukrittayakamee, Sasithon; Jittamala, Podjanee; Chuthasmit, Kittiphum; Cheung, Ming S; Feng, Yiyan; Li, Ruobing; Magnusson, Baldur; Sultan, Marc; Wieser, Daniela; Xun, Xiaolei; Zhao, Rong; Diagana, Thierry T; Pertel, Peter; Leong, F Joel
2016-09-22
KAF156 belongs to a new class of antimalarial agents (imidazolopiperazines), with activity against asexual and sexual blood stages and the preerythrocytic liver stages of malarial parasites. We conducted a phase 2, open-label, two-part study at five centers in Thailand and Vietnam to assess the antimalarial efficacy, safety, and pharmacokinetic profile of KAF156 in adults with acute Plasmodium vivax or P. falciparum malaria. Assessment of parasite clearance rates in cohorts of patients with vivax or falciparum malaria who were treated with multiple doses (400 mg once daily for 3 days) was followed by assessment of the cure rate at 28 days in a separate cohort of patients with falciparum malaria who received a single dose (800 mg). Median parasite clearance times were 45 hours (interquartile range, 42 to 48) in 10 patients with falciparum malaria and 24 hours (interquartile range, 20 to 30) in 10 patients with vivax malaria after treatment with the multiple-dose regimen and 49 hours (interquartile range, 42 to 54) in 21 patients with falciparum malaria after treatment with the single dose. Among the 21 patients who received the single dose and were followed for 28 days, 1 had reinfection and 7 had recrudescent infections (cure rate, 67%; 95% credible interval, 46 to 84). The mean (±SD) KAF156 terminal elimination half-life was 44.1±8.9 hours. There were no serious adverse events in this small study. The most common adverse events included sinus bradycardia, thrombocytopenia, hypokalemia, anemia, and hyperbilirubinemia. Vomiting of grade 2 or higher occurred in 2 patients, 1 of whom discontinued treatment because of repeated vomiting after receiving the single 800-mg dose. More adverse events were reported in the single-dose cohort, which had longer follow-up, than in the multiple-dose cohorts. KAF156 showed antimalarial activity without evident safety concerns in a small number of adults with uncomplicated P. vivax or P. falciparum malaria. (Funded by Novartis and others; ClinicalTrials.gov number, NCT01753323 .).
Cyclodiode photocoagulation for refractory glaucoma after penetrating keratoplasty.
Shah, P; Lee, G A; Kirwan, J K; Bunce, C; Bloom, P A; Ficker, L A; Khaw, P T
2001-11-01
This study analyzes the results of intraocular pressure (IOP) reduction by contact diode cycloablation (cyclodiode) in cases of refractory glaucoma after penetrating keratoplasty. Retrospective noncomparative, interventional case series. Twenty-eight eyes in 28 patients attending the Moorfields Eye Hospital. Cyclodiode (40 applications x 1.5 W x 1.5 seconds over 270-300 degrees ) was used to control the IOP in refractory glaucoma after penetrating keratoplasty. Postoperative IOP, graft status, visual acuity, and number of antiglaucoma medications were recorded after cyclodiode treatment. Cyclodiode resulted in a reduction of IOP from a median of 33 mmHg (interquartile range [28, 40.5]) to a median of 15 mmHg (interquartile range [12, 20.5]). Most patients had a significant lowering in IOP with a median reduction of 16 mmHg (interquartile range [12, 25]; P < 0.0001). IOPs of 6 to 21 mmHg were achieved in 22 patients (79%). Sixteen patients (57%) required more than one treatment with cyclodiode to control the IOP, with three patients (11%) requiring three treatments and two patients (7%) requiring four treatments. Visual acuity improved (> two Snellen lines of acuity) in three patients (11%) and remained the same (+/- one Snellen line) in 17 patients (61%). The mean number of antiglaucoma medications before cycloablation was 2.6 and was 1.8 after treatment (P < 0.001). Of the 19 patients (68%) with originally clear grafts, three grafts (16%) developed opacification. One patient (4%), with a history of nanophthalmos and recurrent uveal effusion, had delayed hypotony (IOP < 6 mmHg) occurring 46 months after the diode treatment. All patients had at least 6 months follow-up. These patients have often undergone multiple previous complicated ocular interventions and are often not suitable for filtration surgery. Reduction of IOP with maintenance of visual acuity and a good safety profile was achieved in most patients in this study but may require multiple treatments. We propose cyclodiode as an effective treatment for many patients in the management of refractory glaucoma after penetrating keratoplasty.
King, D; Hume, P; Gissane, C; Brughelli, M; Clark, T
2016-02-01
Head impacts and resulting head accelerations cause concussive injuries. There is no standard for reporting head impact data in sports to enable comparison between studies. The aim was to outline methods for reporting head impact acceleration data in sport and the effect of the acceleration thresholds on the number of impacts reported. A systematic review of accelerometer systems utilised to report head impact data in sport was conducted. The effect of using different thresholds on a set of impact data from 38 amateur senior rugby players in New Zealand over a competition season was calculated. Of the 52 studies identified, 42% reported impacts using a >10-g threshold, where g is the acceleration of gravity. Studies reported descriptive statistics as mean ± standard deviation, median, 25th to 75th interquartile range, and 95th percentile. Application of the varied impact thresholds to the New Zealand data set resulted in 20,687 impacts of >10 g, 11,459 (45% less) impacts of >15 g, and 4024 (81% less) impacts of >30 g. Linear and angular raw data were most frequently reported. Metrics combining raw data may be more useful; however, validity of the metrics has not been adequately addressed for sport. Differing data collection methods and descriptive statistics for reporting head impacts in sports limit inter-study comparisons. Consensus on data analysis methods for sports impact assessment is needed, including thresholds. Based on the available data, the 10-g threshold is the most commonly reported impact threshold and should be reported as the median with 25th and 75th interquartile ranges as the data are non-normally distributed. Validation studies are required to determine the best threshold and metrics for impact acceleration data collection in sport. Until in-field validation studies are completed, it is recommended that head impact data should be reported as median and interquartile ranges using the 10-g impact threshold.
Shahian, David M; He, Xia; Jacobs, Jeffrey P; Kurlansky, Paul A; Badhwar, Vinay; Cleveland, Joseph C; Fazzalari, Frank L; Filardo, Giovanni; Normand, Sharon-Lise T; Furnary, Anthony P; Magee, Mitchell J; Rankin, J Scott; Welke, Karl F; Han, Jane; O'Brien, Sean M
2015-10-01
Previous composite performance measures of The Society of Thoracic Surgeons (STS) were estimated at the STS participant level, typically a hospital or group practice. The STS Quality Measurement Task Force has now developed a multiprocedural, multidimensional composite measure suitable for estimating the performance of individual surgeons. The development sample from the STS National Database included 621,489 isolated coronary artery bypass grafting procedures, isolated aortic valve replacement, aortic valve replacement plus coronary artery bypass grafting, mitral, or mitral plus coronary artery bypass grafting procedures performed by 2,286 surgeons between July 1, 2011, and June 30, 2014. Each surgeon's composite score combined their aggregate risk-adjusted mortality and major morbidity rates (each weighted inversely by their standard deviations) and reflected the proportion of case types they performed. Model parameters were estimated in a Bayesian framework. Composite star ratings were examined using 90%, 95%, or 98% Bayesian credible intervals. Measure reliability was estimated using various 3-year case thresholds. The final composite measure was defined as 0.81 × (1 minus risk-standardized mortality rate) + 0.19 × (1 minus risk-standardized complication rate). Risk-adjusted mortality (median, 2.3%; interquartile range, 1.7% to 3.0%), morbidity (median, 13.7%; interquartile range, 10.8% to 17.1%), and composite scores (median, 95.4%; interquartile range, 94.4% to 96.3%) varied substantially across surgeons. Using 98% Bayesian credible intervals, there were 207 1-star (lower performance) surgeons (9.1%), 1,701 2-star (as-expected performance) surgeons (74.4%), and 378 3-star (higher performance) surgeons (16.5%). With an eligibility threshold of 100 cases over 3 years, measure reliability was 0.81. The STS has developed a multiprocedural composite measure suitable for evaluating performance at the individual surgeon level. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Weiss, Scott L; Fitzgerald, Julie C; Balamuth, Fran; Alpern, Elizabeth R; Lavelle, Jane; Chilutti, Marianne; Grundmeier, Robert; Nadkarni, Vinay M; Thomas, Neal J
2014-11-01
Delayed antimicrobials are associated with poor outcomes in adult sepsis, but data relating antimicrobial timing to mortality and organ dysfunction in pediatric sepsis are limited. We sought to determine the impact of antimicrobial timing on mortality and organ dysfunction in pediatric patients with severe sepsis or septic shock. Retrospective observational study. PICU at an academic medical center. One hundred thirty patients treated for severe sepsis or septic shock. None. We determined if hourly delays from sepsis recognition to initial and first appropriate antimicrobial administration were associated with PICU mortality (primary outcome); ventilator-free, vasoactive-free, and organ failure-free days; and length of stay. Median time from sepsis recognition to initial antimicrobial administration was 140 minutes (interquartile range, 74-277 min) and to first appropriate antimicrobial was 177 minutes (90-550 min). An escalating risk of mortality was observed with each hour delay from sepsis recognition to antimicrobial administration, although this did not achieve significance until 3 hours. For patients with more than 3-hour delay to initial and first appropriate antimicrobials, the odds ratio for PICU mortality was 3.92 (95% CI, 1.27-12.06) and 3.59 (95% CI, 1.09-11.76), respectively. These associations persisted after adjustment for individual confounders and a propensity score analysis. After controlling for severity of illness, the odds ratio for PICU mortality increased to 4.84 (95% CI, 1.45-16.2) and 4.92 (95% CI, 1.30-18.58) for more than 3-hour delay to initial and first appropriate antimicrobials, respectively. Initial antimicrobial administration more than 3 hours was also associated with fewer organ failure-free days (16 [interquartile range, 1-23] vs 20 [interquartile range, 6-26]; p = 0.04). Delayed antimicrobial therapy was an independent risk factor for mortality and prolonged organ dysfunction in pediatric sepsis.
Delayed Antimicrobial Therapy Increases Mortality and Organ Dysfunction Duration in Pediatric Sepsis
Weiss, Scott L.; Fitzgerald, Julie C.; Balamuth, Fran; Alpern, Elizabeth R.; Lavelle, Jane; Chilutti, Marianne; Grundmeier, Robert; Nadkarni, Vinay M.; Thomas, Neal J.
2014-01-01
Objectives Delayed antimicrobials are associated with poor outcomes in adult sepsis, but data relating antimicrobial timing to mortality and organ dysfunction in pediatric sepsis are limited. We sought to determine the impact of antimicrobial timing on mortality and organ dysfunction in pediatric patients with severe sepsis or septic shock. Design Retrospective observational study. Setting PICU at an academic medical center. Patients One hundred thirty patients treated for severe sepsis or septic shock. Interventions None. Measurements and Main Results We determined if hourly delays from sepsis recognition to initial and first appropriate antimicrobial administration were associated with PICU mortality (primary outcome); ventilator-free, vasoactive-free, and organ failure–free days; and length of stay. Median time from sepsis recognition to initial antimicrobial administration was 140 minutes (interquartile range, 74–277 min) and to first appropriate antimicrobial was 177 minutes (90–550 min). An escalating risk of mortality was observed with each hour delay from sepsis recognition to antimicrobial administration, although this did not achieve significance until 3 hours. For patients with more than 3-hour delay to initial and first appropriate antimicrobials, the odds ratio for PICU mortality was 3.92 (95% CI, 1.27–12.06) and 3.59 (95% CI, 1.09–11.76), respectively. These associations persisted after adjustment for individual confounders and a propensity score analysis. After controlling for severity of illness, the odds ratio for PICU mortality increased to 4.84 (95% CI, 1.45–16.2) and 4.92 (95% CI, 1.30–18.58) for more than 3-hour delay to initial and first appropriate antimicrobials, respectively. Initial antimicrobial administration more than 3 hours was also associated with fewer organ failure–free days (16 [interquartile range, 1–23] vs 20 [interquartile range, 6–26]; p = 0.04). Conclusions Delayed antimicrobial therapy was an independent risk factor for mortality and prolonged organ dysfunction in pediatric sepsis. PMID:25148597
Levin, Phillip D; Golovanevski, Mila; Moses, Allon E; Sprung, Charles L; Benenson, Shmuel
2011-01-01
The role of ICU design and particularly single-patient rooms in decreasing bacterial transmission between ICU patients has been debated. A recent change in our ICU allowed further investigation. Pre-move ICU-A and pre-move ICU-B were open-plan units. In March 2007, ICU-A moved to single-patient rooms (post-move ICU-A). ICU-B remained unchanged (post-move ICU-B). The same physicians cover both ICUs. Cultures of specified resistant organisms in surveillance or clinical cultures from consecutive patients staying >48 hours were compared for the different ICUs and periods to assess the effect of ICU design on acquisition of resistant organisms. Data were collected for 62, 62, 44 and 39 patients from pre-move ICU-A, post-move ICU-A, pre-move ICU-B and post-move ICU-B, respectively. Fewer post-move ICU-A patients acquired resistant organisms (3/62, 5%) compared with post-move ICU-B patients (7/39, 18%; P = 0.043, P = 0.011 using survival analysis) or pre-move ICU-A patients (14/62, 23%; P = 0.004, P = 0.012 on survival analysis). Only the admission period was significant for acquisition of resistant organisms comparing pre-move ICU-A with post-move ICU-A (hazard ratio = 5.18, 95% confidence interval = 1.03 to 16.06; P = 0.025). More antibiotic-free days were recorded in post-move ICU-A (median = 3, interquartile range = 0 to 5) versus post-move ICU-B (median = 0, interquartile range = 0 to 4; P = 0.070) or pre-move ICU-A (median = 0, interquartile range = 0 to 4; P = 0.017). Adequate hand hygiene was observed on 140/242 (58%) occasions in post-move ICU-A versus 23/66 (35%) occasions in post-move ICU-B (P < 0.001). Improved ICU design, and particularly use of single-patient rooms, decreases acquisition of resistant bacteria and antibiotic use. This observation should be considered in future ICU design.
Lee, Hong-Shik; Kim, Haeng-In; Lee, Sang-Shin
2012-06-10
A compact laser transmitter, which takes advantage of an optical subassembly module, was proposed and demonstrated, providing precisely aligned collinear IR and visible beams. The collimated IR beam acts as a long-range projectile for simulated combat, carrying an optical pulsed signal, whereas the visible beam plays the role of tracking the IR beam. The proposed laser transmitter utilizes IR (λ(1)=905 nm) and visible (λ(2)=660 nm) light sources, a fiber-optic collimator, and a beam combiner, which includes a wavelength division multiplexing (WDM) filter in conjunction with optical fiber. The device was built via the laser welding technique and then evaluated by investigating the characteristics of the generated light beams. The IR collimated beam produced had a Gaussian profile and a divergence angle of ~1.3 mrad, and the visible monitoring beam was appropriately collimated to be readily discernible in the vicinity of the transmitter. The two beams were highly aligned within an angle of 0.004 deg as anticipated. Finally, we performed a practical outdoor field test to assess the IR beam with the help of a receiver. An effective trajectory was observed ranging up to 660 m with an overall detectable beam width of ~60 cm.
High-power, continuous-wave, tunable mid-IR, higher-order vortex beam optical parametric oscillator
NASA Astrophysics Data System (ADS)
Aadhi, A.; Sharma, Varun; Samanta, G. K.
2018-05-01
We report on a novel experimental scheme to generate continuous-wave (cw), high power, and higher-order optical vortices tunable across mid-IR wavelength range. Using cw, two-crystal, singly resonant optical parametric oscillator (T-SRO) and pumping one of the crystals with Gaussian beam and the other crystal with optical vortices of orders, lp = 1 to 6, we have directly transferred the vortices at near-IR to the mid-IR wavelength range. The idler vortices of orders, li = 1 to 6, are tunable across 2276-3576 nm with a maximum output power of 6.8 W at order of, li = 1, for the pump power of 25 W corresponding to a near-IR vortex to mid-IR vortex conversion efficiency as high as 27.2%. Unlike the SROs generating optical vortices restricted to lower orders due to the elevated operation threshold with pump vortex orders, here, the coherent energy coupling between the resonant signals of the crystals of T-SRO facilitates the transfer of pump vortex of any order to the idler wavelength without stringent operation threshold condition. The generic experimental scheme can be used in any wavelength range across the electromagnetic spectrum and in all time scales from cw to ultrafast regime.
Cieminski, Cort J; Kelly, Shannon M; Nawrocki, Tatia J; Indrelie, Alisse J; Klaers, Hugo; Stelzmiller, Michael R
2016-09-01
Loss of shoulder internal rotation (IR) range of motion (ROM) is prevalent in overhead athletes, but it can also be seen in nonathletic persons. A paucity of normative data exists, however, for shoulder IR ROM in positions other than supine, especially in nonathletic persons. The aim of this study was to determine shoulder IR ROM differences between the sidelying, semi-sidelying, and supine positions as well as to establish initial normative values for IR ROM for the sidelying and semi-sidelying positions in nonathletic persons. IR ROM was measured on 204 nonathletic persons using the sidelying, semi-sidelying, and supine positions. Mean values of IR ROM for each position were calculated. Differences in IR ROM across the 3 positions and side-to-side differences were examined, including the influence of sex and age on IR ROM. Intra-rater and inter-rater reliability for the sidelying position was excellent. The sidelying position had significantly less IR ROM compared with the other positions, and there was a significant side-to-side IR ROM difference, greatest for the sidelying position (6.8°). Women had significantly more IR ROM than men did, with sidelying normative values of 49° and 55° for female dominant and nondominant shoulders, respectively, and 42° and 51° for male dominant and nondominant shoulders, respectively. This investigation establishes initial normative IR ROM values for the sidelying position for both shoulders and sexes. Health care providers can begin to examine IR ROM deficits using these normative values for the sidelying position. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Neurogranin as a Cerebrospinal Fluid Biomarker for Synaptic Loss in Symptomatic Alzheimer Disease
Kester, Maartje I.; Teunissen, Charlotte E.; Crimmins, Daniel L.; Herries, Elizabeth M.; Ladenson, Jack. H.; Scheltens, Philip; van der Flier, Wiesje M.; Morris, John C.; Holtzman, David M.; Fagan, Anne M.
2015-01-01
IMPORTANCE Neurogranin (NGRN) seems to be a promising novel cerebrospinal fluid (CSF) biomarker for synaptic loss; however, clinical, and especially longitudinal, data are sparse. OBJECTIVE To examine the utility of NGRN, with repeated CSF sampling, for diagnosis, prognosis, and monitoring of Alzheimer disease (AD). DESIGN, SETTING, AND PARTICIPANTS Longitudinal study of consecutive patients who underwent 2 lumbar punctures between the beginning of 1995 and the end of 2010 within the memory clinic–based Amsterdam Dementia Cohort. The study included 163 patients: 37 cognitively normal participants (mean [SE] age, 64 [2] years; 38% female; and mean [SE] Mini-Mental State Examination [MMSE] score, 28 [0.3]), 61 patients with mild cognitive impairment (MCI) (mean [SE] age, 68 [1] years; 38% female; and mean [SE] MMSE score, 27 [0.3]), and 65 patients with AD (mean [SE] age, 65 [1] years; 45% female; and mean [SE] MMSE score, 22 [0.7]). The mean (SE) interval between lumbar punctures was 2.0 (0.1) years, and the mean (SE) duration of cognitive follow-up was 3.8 (0.2) years. Measurements of CSF NGRN levels were obtained in January and February 2014. MAIN OUTCOME AND MEASURE Levels of NGRN in CSF samples. RESULTS Baseline CSF levels of NGRN in patients with AD (median level, 2381 pg/mL [interquartile range, 1651-3416 pg/mL]) were higher than in cognitively normal participants (median level, 1712 pg/mL [interquartile range, 1206-2724 pg/mL]) (P = .04). Baseline NGRN levels were highly correlated with total tau and tau phosphorylated at threonine 181 in all patient groups (all P < .001), but not with Aβ42. Baseline CSF levels of NGRN were also higher in patients with MCI who progressed to AD (median level, 2842 pg/mL [interquartile range, 1882-3950 pg/mL]) compared with those with stable MCI (median level, 1752 pg/mL [interquartile range, 1024-2438 pg/mL]) (P = .004), and they were predictive of progression from MCI to AD (hazard ratio, 1.8 [95% CI, 1.1-2.9]; stratified by tertiles). Linear mixed-model analyses demonstrated that within-person levels of NGRN increased over time in cognitively normal participants (mean [SE] level, 90 [45] pg/mL per year; P < .05) but not in patients with MCI or AD. CONCLUSIONS AND RELEVANCE Neurogranin is a promising biomarker for AD because levels were elevated in patients with AD compared with cognitively normal participants and predicted progression from MCI to AD. Within-person levels of NGRN increased in cognitively normal participants but not in patients with later stage MCI or AD, which suggests that NGRN may reflect presymptomatic synaptic dysfunction or loss. PMID:26366630
Microcystic macular oedema in multiple sclerosis is associated with disease severity
Gelfand, Jeffrey M.; Nolan, Rachel; Schwartz, Daniel M.; Graves, Jennifer
2012-01-01
Macular oedema typically results from blood–retinal barrier disruption. It has recently been reported that patients with multiple sclerosis treated with FTY-720 (fingolimod) may exhibit macular oedema. Multiple sclerosis is not otherwise thought to be associated with macular oedema except in the context of comorbid clinical uveitis. Despite a lack of myelin, the retina is a site of inflammation and microglial activation in multiple sclerosis and demonstrates significant neuronal and axonal loss. We unexpectedly observed microcystic macular oedema using spectral domain optical coherence tomography in patients with multiple sclerosis who did not have another reason for macular oedema. We therefore evaluated spectral domain optical coherence tomography images in consecutive patients with multiple sclerosis for microcystic macular oedema and examined correlations between macular oedema and visual and ambulatory disability in a cross-sectional analysis. Participants were excluded if there was a comorbidity that could account for the presence of macular oedema, such as uveitis, diabetes or other retinal disease. A microcystic pattern of macular oedema was observed on optical coherence tomography in 15 of 318 (4.7%) patients with multiple sclerosis. No macular oedema was identified in 52 healthy controls assessed over the same period. The microcystic oedema predominantly involved the inner nuclear layer of the retina and tended to occur in small, discrete patches. Patients with multiple sclerosis with microcystic macular oedema had significantly worse disability [median Expanded Disability Score Scale 4 (interquartile range 3–6)] than patients without macular oedema [median Expanded Disability Score Scale 2 (interquartile range 1.5–3.5)], P = 0.0002. Patients with multiple sclerosis with microcystic macular oedema also had higher Multiple Sclerosis Severity Scores, a measure of disease progression, than those without oedema [median of 6.47 (interquartile range 4.96–7.98) versus 3.65 (interquartile range 1.92–5.87), P = 0.0009]. Microcystic macular oedema occurred more commonly in eyes with prior optic neuritis than eyes without prior optic neuritis (50 versus 27%) and was associated with lower visual acuity (median logMAR acuity of 0.17 versus −0.1) and a thinner retinal nerve fibre layer. The presence of microcystic macular oedema in multiple sclerosis suggests that there may be breakdown of the blood–retinal barrier and tight junction integrity in a part of the nervous system that lacks myelin. Microcystic macular oedema may also contribute to visual dysfunction beyond that explained by nerve fibre layer loss. Microcystic changes need to be assessed, and potentially adjusted for, in clinical trials that evaluate macular volume as a marker of retinal ganglion cell survival. These findings also have implications for clinical monitoring in patients with multiple sclerosis on sphingosine 1-phosphate receptor modulating agents. PMID:22539259
Site Variability in Regulatory Oversight for an International Study of Pediatric Sepsis.
Michelson, Kelly N; Reubenson, Gary; Weiss, Scott L; Fitzgerald, Julie C; Ackerman, Kate K; Christie, LeeAnn; Bush, Jenny L; Nadkarni, Vinay M; Thomas, Neal J; Schreiner, Mark S
2018-04-01
Duplicative institutional review board/research ethics committee review for multicenter studies may impose administrative burdens and inefficiencies affecting study implementation and quality. Understanding variability in site-specific institutional review board/research ethics committee assessment and barriers to using a single review committee (an increasingly proposed solution) can inform a more efficient process. We provide needed data about the regulatory oversight process for the Sepsis PRevalence, OUtcomes, and Therapies multicenter point prevalence study. Survey. Sites invited to participate in Sepsis PRevalence, OUtcomes, and Therapies. Investigators at sites that expressed interest and/or participated in Sepsis PRevalence, OUtcomes, and Therapies. None. Using an electronic survey, we collected data about 1) logistics of protocol submission, 2) institutional review board/research ethics committee requested modifications, and 3) use of a single institutional review board (for U.S. sites). We collected surveys from 104 of 167 sites (62%). Of the 97 sites that submitted the protocol for institutional review board/research ethics committee review, 34% conducted full board review, 54% expedited review, and 4% considered the study exempt. Time to institutional review board/research ethics committee approval required a median of 34 (range 3-186) days, which took longer at sites that required protocol modifications (median [interquartile range] 50 d [35-131 d] vs 32 d [14-54 d)]; p = 0.02). Enrollment was delayed at eight sites due to prolonged (> 50 d) time to approval. Of 49 U.S. sites, 43% considered using a single institutional review board, but only 18% utilized this option. Time to final approval for U.S. sites using the single institutional review board was 62 days (interquartile range, 34-70 d) compared with 34 days (interquartile range, 15-54 d) for nonsingle institutional review board sites (p = 0.16). Variability in regulatory oversight was evident for this minimal-risk observational research study, most notably in the category of type of review conducted. Duplicative review prolonged time to protocol approval at some sites. Use of a single institutional review board for U.S. sites was rare and did not improve efficiency of protocol approval. Suggestions for minimizing these challenges are provided.
NASA Astrophysics Data System (ADS)
Li, Xin; Liang, Ji; Zhang, Hongxiang; Yang, Xing; Zhang, Hao; Pang, Wei; Zhang, Menglun
2017-06-01
This paper reports an uncooled infrared (IR) detector based on a micromachined piezoelectric resonator operating in resonant and resistive dual-modes. The two sensing modes achieved IR responsivities of 2.5 Hz/nW and 900 μdB/nW, respectively. Compared with the single mode operation, the dual-mode measurement improves the limit of detection by two orders of magnitude and meanwhile maintains high linearity and responsivity in a higher IR intensity range. A combination of the two sensing modes compensates for its own shortcomings and provides a much larger dynamic range, and thus, a wider application field of the proposed detector is realized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danilov, P A; Zayarnyi, D A; Ionin, A A
The specific features of photofragmentation of sols of gold nanoparticles under focused femtosecond laser pulses in IR (1030 nm) and visible (515 nm) ranges is experimentally investigated. A high photofragmentation efficiency of nanoparticles in the waist of a pulsed laser beam in the visible range (at moderate radiation scattering) is demonstrated; this efficiency is related to the excitation of plasmon resonance in nanoparticles on the blue shoulder of its spectrum, in contrast to the regime of very weak photofragmentation in an IR-laser field of comparable intensity. Possible mechanisms of femtosecond laser photofragmentation of gold nanoparticles are discussed. (extreme light fieldsmore » and their applications)« less
Validation of an algorithm to predict reulceration in amputation patients with diabetes.
Molines-Barroso, Raúl J; Lázaro-Martínez, José L; Álvaro-Afonso, Francisco J; Sanz-Corbalán, Irene; García-Klepzig, José L; Aragón-Sánchez, Javier
2017-06-01
The aim of this article was to assess the ability to predict reulceration in people with diabetes and a history of minor amputation according to the formula proposed by Miller et al. A retrospective study was performed on 156 consecutive records of patients with a recent history of simple or multiple forefoot amputation. The sample was divided according to Miller's formula into patients at low risk of reulceration and those at high risk; those were further divided into two subgroups according to whether or not the first segment of the forefoot had been amputated. Forty-eight (47·1%) individuals suffered forefoot reulceration, showing a median reulceration-free survival time of 8 months [interquartile range (IR) 3·6-14·8]. Nephropathy (P = 0.005) and Miller's formula (P = 0.028) were risk factors for reulceration-free survival time in the univariate analysis. The pattern relating to the first segment amputated [hazard ratio (HR) 2·853; P = 0·004; 95% confidence interval (CI) 1·391-5·849] and nephropathy (HR 2·468; P = 0.004; 95% CI 1.328-4.587) showed a significant hazard ratio in the multivariate Cox model. Participants with first segment amputation and one other amputation showed an association with the probability of reulceration in comparison with any other specific type of minor amputation. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Application of infrared uncooled cameras in surveillance systems
NASA Astrophysics Data System (ADS)
Dulski, R.; Bareła, J.; Trzaskawka, P.; PiÄ tkowski, T.
2013-10-01
The recent necessity to protect military bases, convoys and patrols gave serious impact to the development of multisensor security systems for perimeter protection. One of the most important devices used in such systems are IR cameras. The paper discusses technical possibilities and limitations to use uncooled IR camera in a multi-sensor surveillance system for perimeter protection. Effective ranges of detection depend on the class of the sensor used and the observed scene itself. Application of IR camera increases the probability of intruder detection regardless of the time of day or weather conditions. It also simultaneously decreased the false alarm rate produced by the surveillance system. The role of IR cameras in the system was discussed as well as technical possibilities to detect human being. Comparison of commercially available IR cameras, capable to achieve desired ranges was done. The required spatial resolution for detection, recognition and identification was calculated. The simulation of detection ranges was done using a new model for predicting target acquisition performance which uses the Targeting Task Performance (TTP) metric. Like its predecessor, the Johnson criteria, the new model bounds the range performance with image quality. The scope of presented analysis is limited to the estimation of detection, recognition and identification ranges for typical thermal cameras with uncooled microbolometer focal plane arrays. This type of cameras is most widely used in security systems because of competitive price to performance ratio. Detection, recognition and identification range calculations were made, and the appropriate results for the devices with selected technical specifications were compared and discussed.
Hip and ankle range of motion and hip muscle strength in young female ballet dancersand controls
Bennell, K.; Khan, K. M.; Matthews, B.; De Gruyter, M.; Cook, E.; Holzer, K.; Wark, J. D.
1999-01-01
OBJECTIVES: To compare the hip and ankle range of motion and hip muscle strength in 8-11 year old novice female ballet dancers and controls. METHODS: Subjects were 77 dancers and 49 controls (mean (SD) age 9.6 (0.8) and 9.6 (0.7) years respectively). Supine right active hip external rotation (ER) and internal rotation (IR) were measured using an inclinometer. A turnout protractor was used to assess standing active turnout range. The measure of ER achieved from below the hip during turnout (non-hip ER) was calculated by subtracting hip ER range from turnout range, and hip ER:IR was derived by dividing ER range by IR range. Range of right weight bearing ankle dorsiflexion was measured in a standing lunge using two methods: the distance from the foot to the wall (in centimetres) and the angle of the shank to the vertical via an inclinometer (in degrees). Right calf muscle range was measured in weight bearing using an inclinometer. A manual muscle tester was used to assess right isometric hip flexor, internal rotator, external rotator, abductor, and adductor strength. RESULTS: Dancers had less ER (p<0.05) and IR (p<0.01) range than controls but greater ER:IR (p<0.01). Although there was no difference in turnout between groups, the dancers had greater non-hip ER. Dancers had greater range of ankle dorsiflexion than controls, measured in both centimetres (p<0.01) and degrees (p<0.05), but similar calf muscle range. After controlling for body weight, controls had stronger hip muscles than dancers except for hip abductor strength which was similar. Regression analyses disclosed a moderate relation between turnout and hip ER (r = 0.40). There were no significant correlations between range of motion and training years and weekly training hours. CONCLUSIONS: Longitudinal follow up will assist in determining whether or not hip and ankle range in young dancers is genetically fixed and unable to be improved with further balletic training. PMID:10522638
Intentionally Short Range Communications (ISRC)
1993-05-01
ere known to the author. The first effort to develop a portable short-range communicator v, as in the carly- 1980s ( Hislop , 1982). The other was a...happenstance. The only previous effort known to the author to deliberately limit IR range was a proposal in the mid- 1980s . This attempt to develop an IR laser...B. Johnson, J. H. Yen. and G. A. Clapp. 1986. "Short-Range UV Communication Links," Proc. Tact. Comm. Conf. 1,60. Hislop , A. R. 1982. "A Head-Worn 60
On the Use of Rank Tests and Estimates in the Linear Model.
1982-06-01
assumption A5, McKean and Hettmansperger (1976) show that 10 w (W(N-c) - W (c+l))/ (2Z /2) (14) where 2Z is the 1-a interpercentile range of the standard...r(.75n) - r(.25n)) (13) The window width h incorporates a resistant estimate of scale, then interquartile range of the residuals, and a normalizing...alternative estimate of i is available with the additional assumption of symmetry of the error distribution. ASSUMPTION: A5. Suppose the underlying error
Qu, Hui-Qi; Li, Quan; Rentfro, Anne R; Fisher-Hoch, Susan P; McCormick, Joseph B
2011-01-01
The lack of standardized reference range for the homeostasis model assessment-estimated insulin resistance (HOMA-IR) index has limited its clinical application. This study defines the reference range of HOMA-IR index in an adult Hispanic population based with machine learning methods. This study investigated a Hispanic population of 1854 adults, randomly selected on the basis of 2000 Census tract data in the city of Brownsville, Cameron County. Machine learning methods, support vector machine (SVM) and Bayesian Logistic Regression (BLR), were used to automatically identify measureable variables using standardized values that correlate with HOMA-IR; K-means clustering was then used to classify the individuals by insulin resistance. Our study showed that the best cutoff of HOMA-IR for identifying those with insulin resistance is 3.80. There are 39.1% individuals in this Hispanic population with HOMA-IR>3.80. Our results are dramatically different using the popular clinical cutoff of 2.60. The high sensitivity and specificity of HOMA-IR>3.80 for insulin resistance provide a critical fundamental for our further efforts to improve the public health of this Hispanic population.
Qu, Hui-Qi; Li, Quan; Rentfro, Anne R.; Fisher-Hoch, Susan P.; McCormick, Joseph B.
2011-01-01
Objective The lack of standardized reference range for the homeostasis model assessment-estimated insulin resistance (HOMA-IR) index has limited its clinical application. This study defines the reference range of HOMA-IR index in an adult Hispanic population based with machine learning methods. Methods This study investigated a Hispanic population of 1854 adults, randomly selected on the basis of 2000 Census tract data in the city of Brownsville, Cameron County. Machine learning methods, support vector machine (SVM) and Bayesian Logistic Regression (BLR), were used to automatically identify measureable variables using standardized values that correlate with HOMA-IR; K-means clustering was then used to classify the individuals by insulin resistance. Results Our study showed that the best cutoff of HOMA-IR for identifying those with insulin resistance is 3.80. There are 39.1% individuals in this Hispanic population with HOMA-IR>3.80. Conclusions Our results are dramatically different using the popular clinical cutoff of 2.60. The high sensitivity and specificity of HOMA-IR>3.80 for insulin resistance provide a critical fundamental for our further efforts to improve the public health of this Hispanic population. PMID:21695082
O'Bichere, Austin; Green, Colin; Phillips, Robin K S
2004-09-01
Water for colostomy irrigation is largely absorbed by the colon, which may result in less efficient expulsion of stool. This study compared the outcome of colonic cleansing with water and polyethylene glycol solution. In a cross-over study, 41 colostomy irrigators were randomly assigned to water or polyethylene glycol solution irrigation first and then the other regimen, each for one week. Patients recorded fluid inflow time, total washout time, cramps, leakage episodes, number of stoma pouches used, and satisfaction scores (Visual Analog Scale, 1-10: 1 = poor, and 10 = excellent). The median and interquartile range for each variable was calculated, and the two treatments were compared (Wilcoxon's test). Eight patients failed to complete the study. Thirty-three patients (20 females; mean age, 55 (range, 39-73) years) provided 352 irrigation sessions: water (n = 176), and polyethylene glycol solution (n = 176). Irrigation was performed every 24, 48, and 72 hours by 17, 9, and 7 patients respectively, using 500 ml (n = 1), 750 ml (n = 2), 1,000 ml (n = 16), 1,500 ml (n = 11), 2,000 ml (n = 2), and 3,500 ml (n = 1) of fluid. The median and interquartile range for water vs. polyethylene glycol solution were: fluid inflow time (6 (range, 4.4-10.8) vs. 6.3 (range, 4.1-11) minutes; P = 0.48), total washout time (53 (range, 33-69) vs. 38 (range, 28-55) minutes; P = 0.01), leakage episodes (2.3 (range, 1.7-3.8) vs. 0.7 (range, 0.2-1); P < 0.001), satisfaction score (5.8 (range, 4-7.5) vs. 8.8 (range, 8.3-10); P < 0.001), and stoma pouch usage per week (75 (range, 45-80) vs. 43 (range, 0-80); P = 0.008). No difference was demonstrated for frequency of cramps ( P = 0.24). Polyethylene glycol solution performed significantly better than water and may be a superior alternative fluid regimen for colostomy irrigation.
Autonomous long-range open area fire detection and reporting
NASA Astrophysics Data System (ADS)
Engelhaupt, Darell E.; Reardon, Patrick J.; Blackwell, Lisa; Warden, Lance; Ramsey, Brian D.
2005-03-01
Approximately 5 billion dollars in US revenue was lost in 2003 due to open area fires. In addition many lives are lost annually. Early detection of open area fires is typically performed by manned observatories, random reporting and aerial surveillance. Optical IR flame detectors have been developed previously. They typically have experienced high false alarms and low flame detection sensitivity due to interference from solar and other causes. Recently a combination of IR detectors has been used in a two or three color mode to reduce false alarms from solar, or background sources. A combination of ultra-violet C (UVC) and near infra-red (NIR) detectors has also been developed recently for flame discrimination. Relatively solar-blind basic detectors are now available but typically detect at only a few tens of meters at ~ 1 square meter fuel flame. We quantify the range and solar issues for IR and visible detectors and qualitatively define UV sensor requirements in terms of the mode of operation, collection area issues and flame signal output by combustion photochemistry. We describe innovative flame signal collection optics for multiple wavelengths using UV and IR as low false alarm detection of open area fires at long range (8-10 km/m2) in daylight (or darkness). A circular array detector and UV-IR reflective and refractive devices including cylindrical or toroidal lens elements for the IR are described. The dispersion in a refractive cylindrical IR lens characterizes the fire and allows a stationary line or circle generator to locate the direction and different flame IR "colors" from a wide FOV. The line generator will produce spots along the line corresponding to the fire which can be discriminated with a linear detector. We demonstrate prototype autonomous sensors with RF digital reporting from various sites.
Birko, Stanislav; Dove, Edward S; Özdemir, Vural
2015-01-01
The extent of consensus (or the lack thereof) among experts in emerging fields of innovation can serve as antecedents of scientific, societal, investor and stakeholder synergy or conflict. Naturally, how we measure consensus is of great importance to science and technology strategic foresight. The Delphi methodology is a widely used anonymous survey technique to evaluate consensus among a panel of experts. Surprisingly, there is little guidance on how indices of consensus can be influenced by parameters of the Delphi survey itself. We simulated a classic three-round Delphi survey building on the concept of clustered consensus/dissensus. We evaluated three study characteristics that are pertinent for design of Delphi foresight research: (1) the number of survey questions, (2) the sample size, and (3) the extent to which experts conform to group opinion (the Group Conformity Index) in a Delphi study. Their impacts on the following nine Delphi consensus indices were then examined in 1000 simulations: Clustered Mode, Clustered Pairwise Agreement, Conger's Kappa, De Moivre index, Extremities Version of the Clustered Pairwise Agreement, Fleiss' Kappa, Mode, the Interquartile Range and Pairwise Agreement. The dependency of a consensus index on the Delphi survey characteristics was expressed from 0.000 (no dependency) to 1.000 (full dependency). The number of questions (range: 6 to 40) in a survey did not have a notable impact whereby the dependency values remained below 0.030. The variation in sample size (range: 6 to 50) displayed the top three impacts for the Interquartile Range, the Clustered Mode and the Mode (dependency = 0.396, 0.130, 0.116, respectively). The Group Conformity Index, a construct akin to measuring stubbornness/flexibility of experts' opinions, greatly impacted all nine Delphi consensus indices (dependency = 0.200 to 0.504), except the Extremity CPWA and the Interquartile Range that were impacted only beyond the first decimal point (dependency = 0.087 and 0.083, respectively). Scholars in technology design, foresight research and future(s) studies might consider these new findings in strategic planning of Delphi studies, for example, in rational choice of consensus indices and sample size, or accounting for confounding factors such as experts' variable degrees of conformity (stubbornness/flexibility) in modifying their opinions.
Birko, Stanislav; Dove, Edward S.; Özdemir, Vural
2015-01-01
The extent of consensus (or the lack thereof) among experts in emerging fields of innovation can serve as antecedents of scientific, societal, investor and stakeholder synergy or conflict. Naturally, how we measure consensus is of great importance to science and technology strategic foresight. The Delphi methodology is a widely used anonymous survey technique to evaluate consensus among a panel of experts. Surprisingly, there is little guidance on how indices of consensus can be influenced by parameters of the Delphi survey itself. We simulated a classic three-round Delphi survey building on the concept of clustered consensus/dissensus. We evaluated three study characteristics that are pertinent for design of Delphi foresight research: (1) the number of survey questions, (2) the sample size, and (3) the extent to which experts conform to group opinion (the Group Conformity Index) in a Delphi study. Their impacts on the following nine Delphi consensus indices were then examined in 1000 simulations: Clustered Mode, Clustered Pairwise Agreement, Conger’s Kappa, De Moivre index, Extremities Version of the Clustered Pairwise Agreement, Fleiss’ Kappa, Mode, the Interquartile Range and Pairwise Agreement. The dependency of a consensus index on the Delphi survey characteristics was expressed from 0.000 (no dependency) to 1.000 (full dependency). The number of questions (range: 6 to 40) in a survey did not have a notable impact whereby the dependency values remained below 0.030. The variation in sample size (range: 6 to 50) displayed the top three impacts for the Interquartile Range, the Clustered Mode and the Mode (dependency = 0.396, 0.130, 0.116, respectively). The Group Conformity Index, a construct akin to measuring stubbornness/flexibility of experts’ opinions, greatly impacted all nine Delphi consensus indices (dependency = 0.200 to 0.504), except the Extremity CPWA and the Interquartile Range that were impacted only beyond the first decimal point (dependency = 0.087 and 0.083, respectively). Scholars in technology design, foresight research and future(s) studies might consider these new findings in strategic planning of Delphi studies, for example, in rational choice of consensus indices and sample size, or accounting for confounding factors such as experts’ variable degrees of conformity (stubbornness/flexibility) in modifying their opinions. PMID:26270647
Remote sensing of planetary properties and biosignatures on extrasolar terrestrial planets
NASA Technical Reports Server (NTRS)
Des Marais, David J.; Harwit, Martin O.; Jucks, Kenneth W.; Kasting, James F.; Lin, Douglas N C.; Lunine, Jonathan I.; Schneider, Jean; Seager, Sara; Traub, Wesley A.; Woolf, Neville J.
2002-01-01
The major goals of NASA's Terrestrial Planet Finder (TPF) and the European Space Agency's Darwin missions are to detect terrestrial-sized extrasolar planets directly and to seek spectroscopic evidence of habitable conditions and life. Here we recommend wavelength ranges and spectral features for these missions. We assess known spectroscopic molecular band features of Earth, Venus, and Mars in the context of putative extrasolar analogs. The preferred wavelength ranges are 7-25 microns in the mid-IR and 0.5 to approximately 1.1 microns in the visible to near-IR. Detection of O2 or its photolytic product O3 merits highest priority. Liquid H2O is not a bioindicator, but it is considered essential to life. Substantial CO2 indicates an atmosphere and oxidation state typical of a terrestrial planet. Abundant CH4 might require a biological source, yet abundant CH4 also can arise from a crust and upper mantle more reduced than that of Earth. The range of characteristics of extrasolar rocky planets might far exceed that of the Solar System. Planetary size and mass are very important indicators of habitability and can be estimated in the mid-IR and potentially also in the visible to near-IR. Additional spectroscopic features merit study, for example, features created by other biosignature compounds in the atmosphere or on the surface and features due to Rayleigh scattering. In summary, we find that both the mid-IR and the visible to near-IR wavelength ranges offer valuable information regarding biosignatures and planetary properties; therefore both merit serious scientific consideration for TPF and Darwin.
Remote sensing of planetary properties and biosignatures on extrasolar terrestrial planets.
Des Marais, David J; Harwit, Martin O; Jucks, Kenneth W; Kasting, James F; Lin, Douglas N C; Lunine, Jonathan I; Schneider, Jean; Seager, Sara; Traub, Wesley A; Woolf, Neville J
2002-01-01
The major goals of NASA's Terrestrial Planet Finder (TPF) and the European Space Agency's Darwin missions are to detect terrestrial-sized extrasolar planets directly and to seek spectroscopic evidence of habitable conditions and life. Here we recommend wavelength ranges and spectral features for these missions. We assess known spectroscopic molecular band features of Earth, Venus, and Mars in the context of putative extrasolar analogs. The preferred wavelength ranges are 7-25 microns in the mid-IR and 0.5 to approximately 1.1 microns in the visible to near-IR. Detection of O2 or its photolytic product O3 merits highest priority. Liquid H2O is not a bioindicator, but it is considered essential to life. Substantial CO2 indicates an atmosphere and oxidation state typical of a terrestrial planet. Abundant CH4 might require a biological source, yet abundant CH4 also can arise from a crust and upper mantle more reduced than that of Earth. The range of characteristics of extrasolar rocky planets might far exceed that of the Solar System. Planetary size and mass are very important indicators of habitability and can be estimated in the mid-IR and potentially also in the visible to near-IR. Additional spectroscopic features merit study, for example, features created by other biosignature compounds in the atmosphere or on the surface and features due to Rayleigh scattering. In summary, we find that both the mid-IR and the visible to near-IR wavelength ranges offer valuable information regarding biosignatures and planetary properties; therefore both merit serious scientific consideration for TPF and Darwin.
System and method for online inspection of turbines using an optical tube with broadspectrum mirrors
Baleine, Erwan
2015-12-22
An optical inspection system for nondestructive internal visual inspection and non-contact infra-red (IR) temperature monitoring of an online, operating power generation turbine. The optical inspection system includes an optical tube having a viewing port, at least one reflective mirror or a mirror array having a reflectivity spectral range from 550 nm to 20 .mu.m, and capable of continuous operation at temperatures greater than 932 degrees Fahrenheit (500 degrees Celsius), and a transparent window with high transmission within the same spectral range mounted distal the viewing port. The same optical mirror array may be used to measure selectively surface temperature of metal turbine blades in the near IR range (approximately 1 .mu.m wavelength) and of thermal barrier coated turbine blades in the long IR range (approximately 10 .mu.m wavelength).
Characteristics of upper limb muscular strength in male wheelchair tennis players
Moon, Hyo-Bin; Park, Seung-Jae; Kim, Al-Chan; Jang, Jee-Hun
2013-01-01
The purpose of this study was to identify the characteristics of muscular strength in upper limb and to present the preliminary information for development of sports injury prevention program and exercise rehabilitation program in wheelchair tennis players. Participants were 12 male wheelchair tennis players. Muscular strength was measured in shoulder and elbow joints with isokinetic dynamometer. Ipsilateral (IR) and bilateral (BR) balance ratio were calculated with isokinetic strength at 60°/sec. As a result, extension strength (ES) was significantly higher than flexion strength (FS) (P< 0.001), and IR in both sides and BR in ES were maintained within normal range whereas BR in FS was lower than normal range in shoulder joint. In elbow joint FS was significantly higher than ES (P< 0.05), and IR and BR were lower than normal range. Consequently, the different tendency in IR between shoulder and elbow joints and lower IR and BR in elbow joints could be the characteristics in male wheelchair tennis players. It is suggested that flexor strengthening program in nondominant shoulder joint, extensor strengthening program in both elbow joint, and flexor strengthening program in non-dominant elbow joint should be introduced for male wheelchair tennis players. PMID:24278887
Schwaighofer, Andreas; Alcaráz, Mirta R.; Araman, Can; Goicoechea, Héctor; Lendl, Bernhard
2016-01-01
Fourier transform infrared (FTIR) and circular dichroism (CD) spectroscopy are analytical techniques employed for the analysis of protein secondary structure. The use of CD spectroscopy is limited to low protein concentrations (<2 mg ml−1), while FTIR spectroscopy is commonly used in a higher concentration range (>5 mg ml−1). Here we introduce a quantum cascade laser (QCL)-based IR transmission setup for analysis of protein and polypeptide secondary structure at concentrations as low as 0.25 mg ml−1 in deuterated buffer solution. We present dynamic QCL-IR spectra of the temperature-induced α-helix to β-sheet transition of poly-L-lysine. The concentration dependence of the α-β transition temperature between 0.25 and 10 mg ml−1 was investigated by QCL-IR, FTIR and CD spectroscopy. By using QCL-IR spectroscopy it is possible to perform IR spectroscopic analysis in the same concentration range as CD spectroscopy, thus enabling a combined analysis of biomolecules secondary structure by CD and IR spectroscopy. PMID:27633337
Schwaighofer, Andreas; Alcaráz, Mirta R; Araman, Can; Goicoechea, Héctor; Lendl, Bernhard
2016-09-16
Fourier transform infrared (FTIR) and circular dichroism (CD) spectroscopy are analytical techniques employed for the analysis of protein secondary structure. The use of CD spectroscopy is limited to low protein concentrations (<2 mg ml(-1)), while FTIR spectroscopy is commonly used in a higher concentration range (>5 mg ml(-1)). Here we introduce a quantum cascade laser (QCL)-based IR transmission setup for analysis of protein and polypeptide secondary structure at concentrations as low as 0.25 mg ml(-1) in deuterated buffer solution. We present dynamic QCL-IR spectra of the temperature-induced α-helix to β-sheet transition of poly-L-lysine. The concentration dependence of the α-β transition temperature between 0.25 and 10 mg ml(-1) was investigated by QCL-IR, FTIR and CD spectroscopy. By using QCL-IR spectroscopy it is possible to perform IR spectroscopic analysis in the same concentration range as CD spectroscopy, thus enabling a combined analysis of biomolecules secondary structure by CD and IR spectroscopy.
NASA Astrophysics Data System (ADS)
Asanova, Tatyana I.; Asanov, Igor P.; Kim, Min-Gyu; Gerasimov, Evgeny Yu.; Zadesenets, Andrey V.; Plyusnin, Pavel E.; Korenev, Sergey V.
2013-10-01
The formation mechanism of Pd-Ir nanoparticles during thermal decomposition of double complex salt [Pd(NH3)4][IrCl6] has been studied by in situ X-ray absorption (XAFS) and photoelectron (XPS) spectroscopies. The changes in the structure of the Pd and Ir closest to the surroundings and chemical states of Pd, Ir, Cl, and N atoms were traced in the range from room temperature to 420 °C in inert atmosphere. It was established that the thermal decomposition process is carried out in 5 steps. The Pd-Ir nanoparticles are formed in pyramidal/rounded Pd-rich (10-200 nm) and dendrite Ir-rich (10-50 nm) solid solutions. A d charge depletion at Ir site and a gain at Pd, as well as the intra-atomic charge redistribution between the outer d and s and p electrons of both Ir and Pd in Pd-Ir nanoparticles, were found to occur.
Sales, Arthur H A; Barz, Melanie; Bette, Stefanie; Wiestler, Benedikt; Ryang, Yu-Mi; Meyer, Bernhard; Bretschneider, Martin; Ringel, Florian; Gempt, Jens
2017-07-25
Postoperative ischemia is a frequent phenomenon in patients with brain tumors and is associated with postoperative neurological deficits and impaired overall survival. Particularly in the field of cardiac and vascular surgery, the application of a brief ischemic stimulus not only in the target organ but also in remote tissues can prevent subsequent ischemic damage. We hypothesized that remote ischemic preconditioning (rIPC) in patients with brain tumors undergoing elective surgical resection reduces the incidence of postoperative ischemic tissue damage and its consequences. Sixty patients were randomly assigned to two groups, with 1:1 allocation, stratified by tumor type (glioma or metastasis) and previous treatment with radiotherapy. rIPC was induced by inflating a blood pressure cuff placed on the upper arm three times for 5 min at 200 mmHg in the treatment group after induction of anesthesia. Between the cycles, the blood pressure cuff was released to allow reperfusion. In the control group no preconditioning was performed. Early postoperative magnetic resonance images (within 72 h after surgery) were evaluated by a neuroradiologist blinded to randomization for the presence of ischemia and its volume. Fifty-eight of the 60 patients were assessed for occurrence of postoperative ischemia. Of these 58 patients, 44 had new postoperative ischemic lesions. The incidence of new postoperative ischemic lesions was significantly higher in the control group (27/31) than in the rIPC group (17/27) (p = 0.03). The median infarct volume was 0.36 cm 3 (interquartile range (IR): 0.0-2.35) in the rIPC group compared with 1.30 cm 3 (IR: 0.29-3.66) in the control group (p = 0.09). Application of rIPC was associated with reduced incidence of postoperative ischemic tissue damage in patients undergoing elective brain tumor surgery. This is the first study indicating a benefit of rIPC in brain tumor surgery. German Clinical Trials Register, DRKS00010409 . Retrospectively registered on 13 October 2016.
Grossmann, Mathis; Hoermann, Rudolf; Francis, Claire; Hamilton, Emma J; Tint, Aye; Kaitu'u-Lino, Tu'uhevaha; Kuswanto, Kent; Lappas, Martha; Sikaris, Ken; Zajac, Jeffery D; Permezel, Michael; Tong, Stephen
2013-05-14
There has been recent evidence suggesting the presence of anti-thyroid peroxidase antibodies (TPOAb) increases the risk of miscarriage, and levothyroxine can rescue miscarriages associated with TPOAb. We propose the most clinically pragmatic cohort to screen for TPOAb are women presenting for management of a missed miscarriage and have never birthed a liveborn. We measured serum TPOAb among nulliparous women presenting for management of miscarriage, and compared levels with women who have had 2 or more livebirths (and never miscarried). Given its potential role in immunomodulation, we also measured Vitamin D levels. We performed a prospective descriptive cohort study at a tertiary hospital (Mercy Hospital for Women, Victoria, Australia). We measured TPOAb and Vitamin D levels in serum obtained from 118 nulliparous women presenting for management of miscarriage, and 162 controls with 2 or more livebirths (and no miscarriages). Controls were selected from a serum biobank prospectively collected in the first trimester at the same hospital. Nulliparous women with 1 or more miscarriages had higher thyroid peroxidase antibody (TPOAb) levels than those with 2 or more livebirths; TPOAb in miscarriage group was 0.3 mIU/L (interquartile range [IR]: 0.2-0.7) vs 0.2 mIU/L among controls (IR 0.0-0.5; p < 0.0001). We confirmed TPOAb levels were not correlated with serum human chorionic gonadotrophin (hCG) concentrations in either the miscarriage or control groups. In contrast, thyroid stimulating hormone, fT3 and fT4 levels (thyroid hormones) either trended towards a correlation, or were significantly correlated with serum hCG levels in the two groups. Of the entire cohort that was predominantly caucasian, only 12% were Vitamin D sufficient. Low Vitamin D levels were not associated with miscarriage. We have confirmed the association between miscarriage and increased TPOAb levels. Furthermore, it appears TPOAb levels in maternal blood are not influenced by serum hCG levels. Therefore, we propose the day nulliparous women present for management for miscarriage is a clinically relevant, and pragmatic time to screen for TPOAb.
Infrared Signature Modeling and Analysis of Aircraft Plume
NASA Astrophysics Data System (ADS)
Rao, Arvind G.
2011-09-01
In recent years, the survivability of an aircraft has been put to task more than ever before. One of the main reasons is the increase in the usage of Infrared (IR) guided Anti-Aircraft Missiles, especially due to the availability of Man Portable Air Defence System (MANPADS) with some terrorist groups. Thus, aircraft IR signatures are gaining more importance as compared to their radar, visual, acoustic, or any other signatures. The exhaust plume ejected from the aircraft is one of the important sources of IR signature in military aircraft that use low bypass turbofan engines for propulsion. The focus of the present work is modelling of spectral IR radiation emission from the exhaust jet of a typical military aircraft and to evaluate the aircraft susceptibility in terms of the aircraft lock-on range due to its plume emission, for a simple case against a typical Surface to Air Missile (SAM). The IR signature due to the aircraft plume is examined in a holistic manner. A comprehensive methodology of computing IR signatures and its affect on aircraft lock-on range is elaborated. Commercial CFD software has been used to predict the plume thermo-physical properties and subsequently an in-house developed code was used for evaluating the IR radiation emitted by the plume. The LOWTRAN code has been used for modeling the atmospheric IR characteristics. The results obtained from these models are in reasonable agreement with some available experimental data. The analysis carried out in this paper succinctly brings out the intricacy of the radiation emitted by various gaseous species in the plume and the role of atmospheric IR transmissivity in dictating the plume IR signature as perceived by an IR guided SAM.
Guney, Hande; Harput, Gulcan; Colakoglu, Filiz; Baltaci, Gul
2016-02-01
Glenohumeral (GH) internal-rotation deficit (GIRD) and lower eccentric external-rotator (ER) to concentric internal-rotator (IR) strength (ER:IR) ratio have been documented as risk factors for shoulder injuries, but there is no information on whether GIRD has an adverse effect on ER:IR ratio in adolescent overhead athletes. The aim of this study was to investigate the effects of GIRD on functional ER:IR ratio of the adolescent overhead athletes. Cross-sectional study. University research laboratory. 52 adolescent overhead athletes. To determine GIRD, the range of GH IR and ER motion was measured with a digital inclinometer. An isokinetic dynamometer was used to assess eccentric and concentric IR and ER muscle strength of the dominant and nondominant shoulders. One-way ANCOVA where sport type was set as a covariate was used to analyze the difference between athletes with and without GIRD. After standardized examinations of all shoulders, the athletes were divided into 2 groups, shoulders with (n = 27) and without GIRD (n = 25). There was a significant difference between groups in functional ER:IR ratio (P < .001). Athletes with GIRD had lower ER:IR ratio (0.56) than athletes without GIRD (0.83). As GIRD has an adverse effect on functional ratio of the shoulder-rotator muscles, interventions for adolescent overhead athletes should include improving GH-rotation range of motion.
NASA Astrophysics Data System (ADS)
Pereverzev, Sergey
2017-02-01
Many life-relevant interaction energies are in IR range, and it is reasonable to believe that some biochemical reactions inside cells can results in emission of IR photons. Cells can use this emission for non-chemical and non-electrical signaling. Detecting weak infrared radiation from live cells is complicated because of strong thermal radiation background and absorption of radiation by tissues. A microfluidic device with live cells inside a vacuum cryogenic environment should suppress this background, and thereby permit observation of live cell auto-luminescence or signaling in the IR regime. One can make IR-transparent windows not emitting in this range, so only the cell and a small amount of liquid around it will emit infrared radiation. Currently mid-IR spectroscopy of single cells requires the use of a synchrotron source to measure absorption or reflection spectra. Decreasing of thermal radiation background will allow absorption and reflection spectroscopy of cells without using synchrotron light. Moreover, cell auto-luminescence can be directly measured. The complete absence of thermal background radiation for cryogenically cooled samples allows the use IR photon-sensitive detectors and obtaining single molecule sensitivity in IR photo-luminescence measurements. Due to low photon energies, photo-luminescence measurements will be non-distractive for pressures samples. The technique described here is based upon US patent 9366574.
Atar, Shaul; Tolstrup, Kirsten; Cercek, Bojan; Siegel, Robert J
2007-07-01
Chlamydia pneumoniae has previously been associated with higher prevalence of valvular and cardiac calcifications. To investigate a possible association of seropositivity for C. pneumoniae and the presence of cardiac calcifications (mitral annular or aortic root calcification, and aortic valve sclerosis). We retrospectively analyzed serological data (immunoglobulin G TWAR antibodies) from the AZACS trial (Azithromycin in Acute Coronary Syndromes), and correlated the serological findings according to titer levels with the presence of cardiac calcifications as detected by transthoracic echocardiography. In 271 patients, age 69 +/- 13 years, who underwent both serological and echocardiographic evaluation, we found no significant association between the "calcification sum score" (on a scale of 0-3) in seropositive compared to seronegative patients (1.56 +/- 1.15 vs.1.35 +/- 1.15, respectively, P = 0.26). The median calcification sum score was 1 (interquartile range 0-3) for the seronegative group, and 2 (interquartile range 0-3) for the seropositive group (P = 0.2757). In addition, we did not find a significant correlation of any of the individual sites of cardiac calcification and C. pneumoniae seropositivity. Our findings suggest that past C. pneumoniae infection may not be associated with the pathogenesis of valvular and cardiac calcifications.
Shaw, Leslee J.; Berman, Daniel S.; Picard, Michael H.; Friedrich, Matthias G.; Kwong, Raymond Y.; Stone, Gregg W.; Senior, Roxy; Min, James K.; Hachamovitch, Rory; Scherrer-Crosbie, Marielle; Mieres, Jennifer H.; Marwick, Thomas H.; Phillips, Lawrence M.; Chaudhry, Farooq A.; Pellikka, Patricia A.; Slomka, Piotr; Arai, Andrew E.; Iskandrian, Ami E.; Bateman, Timothy M.; Heller, Gary V.; Miller, Todd D.; Nagel, Eike; Goyal, Abhinav; Borges-Neto, Salvador; Boden, William E.; Reynolds, Harmony R.; Hochman, Judith S.; Maron, David J.; Douglas, Pamela S.
2014-01-01
The lack of standardized reporting of the magnitude of ischemia on noninvasive imaging contributes to variability in translating the severity of ischemia across stress imaging modalities. We identified the risk of coronary artery disease (CAD) death or myocardial infarction (MI) associated with ≥10% ischemic myocardium on stress nuclear imaging as the risk threshold for stress echocardiography and cardiac magnetic resonance. A narrative review revealed that ≥10% ischemic myocardium on stress nuclear imaging was associated with a median rate of CAD death or MI of 4.9%/year (interquartile range: 3.75% to 5.3%). For stress echocardiography, ≥3 newly dysfunctional segments portend a median rate of CAD death or MI of 4.5%/year (interquartile range: 3.8% to 5.9%). Although imprecisely delineated, moderate-severe ischemia on cardiac magnetic resonance may be indicated by ≥4 of 32 stress perfusion defects or ≥3 dobutamine-induced dysfunctional segments. Risk-based thresholds can define equivalent amounts of ischemia across the stress imaging modalities, which will help to translate a common understanding of patient risk on which to guide subsequent management decisions. PMID:24925328
Issar, Tushar; Arnold, Ria; Kwai, Natalie C G; Pussell, Bruce A; Endre, Zoltan H; Poynten, Ann M; Kiernan, Matthew C; Krishnan, Arun V
2018-05-01
To demonstrate construct validity of the Total Neuropathy Score (TNS) in assessing peripheral neuropathy in subjects with chronic kidney disease (CKD). 113 subjects with CKD and 40 matched controls were assessed for peripheral neuropathy using the TNS. An exploratory factor analysis was conducted and internal consistency of the scale was evaluated using Cronbach's alpha. Construct validity of the TNS was tested by comparing scores between case and control groups. Factor analysis revealed valid item correlations and internal consistency of the TNS was good with a Cronbach's alpha of 0.897. Subjects with CKD scored significantly higher on the TNS (CKD: median, 6, interquartile range, 1-13; controls: median, 0, interquartile range, 0-1; p < 0.001). Subgroup analysis revealed construct validity was maintained for subjects with stages 3-5 CKD with and without diabetes. The TNS is a valid measure of peripheral neuropathy in patients with CKD. The TNS is the first neuropathy scale to be formally validated in patients with CKD. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
A strategy for optimizing staffing to improve the timeliness of inpatient phlebotomy collections.
Morrison, Aileen P; Tanasijevic, Milenko J; Torrence-Hill, Joi N; Goonan, Ellen M; Gustafson, Michael L; Melanson, Stacy E F
2011-12-01
The timely availability of inpatient test results is a key to physician satisfaction with the clinical laboratory, and in an institution with a phlebotomy service may depend on the timeliness of blood collections. In response to safety reports filed for delayed phlebotomy collections, we applied Lean principles to the inpatient phlebotomy service at our institution. Our goal was to improve service without using additional resources by optimizing our staffing model. To evaluate the effect of a new phlebotomy staffing model on the timeliness of inpatient phlebotomy collections. We compared the median time of morning blood collections and average number of safety reports filed for delayed phlebotomy collections during a 6-month preimplementation period and 5-month postimplementation period. The median time of morning collections was 17 minutes earlier after implementation (7:42 am preimplementation; interquartile range, 6:27-8:48 am; versus 7:25 am postimplementation; interquartile range, 6:20-8:26 am). The frequency of safety reports filed for delayed collections decreased 80% from 10.6 per 30 days to 2.2 per 30 days. Reallocating staff to match the pattern of demand for phlebotomy collections throughout the day represents a strategy for improving the performance of an inpatient phlebotomy service.
The Effect of Manual Restraint on Physiological Parameters in Barred Owls ( Strix varia ).
Doss, Grayson A; Mans, Christoph
2017-03-01
Manual restraint is commonly necessary when working with avian species in medical, laboratory, and field settings. Despite their prevalence, little is known about the stress response in raptorial bird species. To further understand the effect of restraint on the stress response in birds of prey, 12 barred owls ( Strix varia ) were manually restrained for 15 minutes. Physiological parameters (cloacal temperature, respiratory rate, heart rate) were followed over time and recorded at defined points during the restraint period. Heart rate decreased significantly over the restraint period by a mean ± SD of -73 ± 46 beats/min. Respiratory rate also decreased significantly (median: -11 breaths/min, interquartile range: -8 to -18). Cloacal temperature increased significantly over time in manually restrained owls (median: +1.5°C [+2.7°F], interquartile range: 1.3°C-2.1°C [2.3°F-3.8°F]). This study is the first to document stress hyperthermia in an owl species. Similar to another raptorial bird, the red-tailed hawk ( Buteo jamaicensis ), both heart rate and respiratory rate decreased and cloacal temperature increased over time in restrained barred owls. Barred owls appear to cope differently to restraint stress when compared to psittacine species.
Differences in sleep architecture between left and right temporal lobe epilepsy.
Nakamura, Miki; Jin, Kazutaka; Kato, Kazuhiro; Itabashi, Hisashi; Iwasaki, Masaki; Kakisaka, Yosuke; Nakasato, Nobukazu
2017-01-01
To investigate whether seizure lateralization affects sleep macrostructure in patients with left and right temporal lobe epilepsy (TLE), as rapid eye movement (REM) sleep is shorter in patients with right hemispheric cerebral infarction than with left. We retrospectively analyzed data from 16 patients with TLE (6 men and 10 women aged 34.9 ± 11.4 years) who underwent polysomnography as well as long-term video electroencephalography. Ten patients were diagnosed with left TLE and six patients with right TLE. Sleep stages and respiratory events were scored based on the American Academy of Sleep Medicine criteria. Sleep and respiratory parameters were compared between the patient groups. Percentage of REM stage sleep was significantly (p < 0.05) lower in patients with left TLE (median 8.8 %, interquartile range 5.5-13.8 %) than in patients with right TLE (median 17.0 %, interquartile range 14.1-18.3 %). The other parameters showed no significant differences. Shorter REM sleep in patients with left TLE sharply contrasts with the previous report of shorter REM sleep in patients with right cerebral infarction. Laterality of the irritative epileptic focus versus destructive lesion may have different effects on the sleep macrostructures.
van der Woude, Olga C P; Cuper, Natascha J; Getrouw, Chavalleh; Kalkman, Cor J; de Graaff, Jurgen C
2013-06-01
Poor vein visibility can make IV cannulation challenging in children with dark skin color. In the operating room, we studied the effectiveness of a near-infrared vascular imaging device (VascuLuminator) to facilitate IV cannulation in children with dark skin color. In the operating room of a general hospital in Curacao, all consecutive children (0-15 years of age) requiring IV cannulation were included in a pragmatic cluster randomized clinical trial. The VascuLuminator was made available to anesthesiologists at the operating complex in randomized clusters of 1 week. Success at first attempt was 63% (27/43, 95% confidence interval [CI], 47%-77%) in the VascuLuminator group vs 51% (23 of 45 patients, 95% CI, 36%-66%) in the control group (P = 0.27). Median time to successful cannulation was 53 seconds (interquartile range: 34-154) in the VascuLuminator group and 68 seconds (interquartile range: 40-159) in the control group (P = 0.54), and hazard ratio was 1.12 (95% CI, 0.73-1.71). The VascuLuminator has limited value in improving success at first attempt of facilitating IV cannulation in children with dark skin color.
Multidrug-resistant tuberculosis around the world: what progress has been made?
Mirzayev, Fuad; Wares, Fraser; Baena, Inés Garcia; Zignol, Matteo; Linh, Nguyen; Weyer, Karin; Jaramillo, Ernesto; Floyd, Katherine; Raviglione, Mario
2015-01-01
Multidrug-resistant tuberculosis (MDR-TB) (resistance to at least isoniazid and rifampicin) will influence the future of global TB control. 88% of estimated MDR-TB cases occur in middle- or high-income countries, and 60% occur in Brazil, China, India, the Russian Federation and South Africa. The World Health Organization collects country data annually to monitor the response to MDR-TB. Notification, treatment enrolment and outcome data were summarised for 30 countries, accounting for >90% of the estimated MDR-TB cases among notified TB cases worldwide. In 2012, a median of 14% (interquartile range 6–50%) of estimated MDR-TB cases were notified in the 30 countries studied. In 15 of the 30 countries, the number of patients treated for MDR-TB in 2012 (71 681) was >50% higher than in 2011. Median treatment success was 53% (interquartile range 40–70%) in the 25 countries reporting data for 30 021 MDR-TB cases who started treatment in 2010. Although progress has been noted in the expansion of MDR-TB care, urgent efforts are required in order to provide wider access to diagnosis and treatment in most countries with the highest burden of MDR-TB. PMID:25261327
Use of Intranasal Dexmedetomidine as a Solo Sedative for MRI of Infants.
Olgun, Gokhan; Ali, Mir Hyder
2018-01-23
Dexmedetomidine, a selective α-2 receptor agonist, can be delivered via the intranasal (IN) route and be used for procedural sedation. The drug's favorable hemodynamic profile and relative ease of application make it a promising agent for sedation during radiologic procedures, although there are few studies on its efficacy for MRI studies. A retrospective chart review was performed between June 2014 and December 2016. Outpatients between 1 and 12 months of age who received 4 μg/kg of IN dexmedetomidine for MRI were included in the analysis. Our aim with this study was to determine the rate of successful completion of the sedation procedure without the need for a rescue drug (other than repeat IN dexmedetomidine). A total of 52 subjects were included in our study. Median (interquartile range) patient age was 7 (5-8) months. Median (interquartile range) procedure length was 40 (35-50) minutes. Overall success rate (including first dose and any rescue dose IN) of dexmedetomidine was 96.2%. None of the patients had significant adverse effects related to dexmedetomidine. IN dexmedetomidine is an effective solo sedative agent for MRI in infants. Copyright © 2018 by the American Academy of Pediatrics.
Doping Evolution of Magnetic Order and Magnetic Excitations in (Sr1 -xLax)3Ir2O7
NASA Astrophysics Data System (ADS)
Lu, Xingye; McNally, D. E.; Moretti Sala, M.; Terzic, J.; Upton, M. H.; Casa, D.; Ingold, G.; Cao, G.; Schmitt, T.
2017-01-01
We use resonant elastic and inelastic x-ray scattering at the Ir-L3 edge to study the doping-dependent magnetic order, magnetic excitations, and spin-orbit excitons in the electron-doped bilayer iridate (Sr1 -xLax )3Ir2 O7 (0 ≤x ≤0.065 ). With increasing doping x , the three-dimensional long range antiferromagnetic order is gradually suppressed and evolves into a three-dimensional short range order across the insulator-to-metal transition from x =0 to 0.05, followed by a transition to two-dimensional short range order between x =0.05 and 0.065. Because of the interactions between the Jeff=1/2 pseudospins and the emergent itinerant electrons, magnetic excitations undergo damping, anisotropic softening, and gap collapse, accompanied by weakly doping-dependent spin-orbit excitons. Therefore, we conclude that electron doping suppresses the magnetic anisotropy and interlayer couplings and drives (Sr1 -xLax )3Ir2 O7 into a correlated metallic state with two-dimensional short range antiferromagnetic order. Strong antiferromagnetic fluctuations of the Jeff=1/2 moments persist deep in this correlated metallic state, with the magnon gap strongly suppressed.
Riveros-Perez, Efrain; Wood, Cristina
2018-03-01
To assess the management and maternal outcomes of placenta accreta spectrum (PAS) disorders. A retrospective chart review was conducted of patients diagnosed with PAS disorders (placenta creta, increta, or percreta) who were treated at a US tertiary care center between February 1, 2011, and January 31, 2016. Obstetric management, anesthetic management, and maternal outcomes were analyzed. A total of 43 cases were identified; placenta previa was diagnosed among 33 (77%). Median age was 33 years (range 23-42). Median blood loss was 1500 mL (interquartile range 1000-2500); blood loss was greatest among the 10 patients with placenta percreta (3250 mL, interquartile range 2200-6000). Transfusion of blood products was necessary among 14 (33%) patients, with no difference in frequency according to the degree of placental invasion (P=0.107). Surgical complications occurred among 10 (23%) patients. Overall, 30 (70%) patients received combined spinal-epidural plus general anesthesia, 4 (9%) received only general anesthesia, and 9 (21%) underwent surgery with combined spinal-epidural anesthesia. One patient experienced difficult airway and another experienced accidental dural puncture. Placenta previa and accreta coexist in many patients, leading to substantial bleeding related to the degree of myometrial invasion. An interdisciplinary team approach plus the use of combined spinal-epidural anesthesia, transitioning to general anesthesia, were advisable and safe. © 2017 International Federation of Gynecology and Obstetrics.
Infrared solar physics from the South Pole
NASA Technical Reports Server (NTRS)
Deming, Drake
1989-01-01
Infrared (IR) observations of the sun could greatly benefit from the quality of the South Pole as an IR site, and the potential for multi-day sequences of uninterrupted observations. A nearly continuous picture of the evolution of the magnetic field in solar active regions could be obtained using vector magnetographs, especially vector magnetographs which incorporate IR array detectors. Observations of the sun over a range of wavelengths in the IR continuum could also be used to study the vertical propagation characteristics of the solar p-mode oscillations.
Near infrared harvesting dye-sensitized solar cells enabled by rare-earth upconversion materials.
Li, Deyang; Ågren, Hans; Chen, Guanying
2018-02-01
Dye-sensitized solar cells (DSSCs) have been deemed as promising alternatives to silicon solar cells for the conversion of clean sunlight energy into electricity. A major limitation to their conversion efficiency is their inability to utilize light in the infrared (IR) spectral range, which constitutes almost half the energy of the sun's radiation. This fact has elicited motivations and endeavors to extend the response wavelength of DSSCs to the IR range. Photon upconversion through rare-earth ions constitutes one of the most promising approaches toward the goal of converting near-IR (NIR) or IR light into visible or ultraviolet light, where DSSCs typically have high sensitivity. In the present review, we summarize recent progress based on the utilization of various upconversion materials and device structures to improve the performance of dye-sensitized solar cells.
Molecular hydrogen in the vicinity of NGC 7538 IRS 1 and IRS 2 - Temperature and ortho-to-para ratio
NASA Technical Reports Server (NTRS)
Hoban, Susan; Reuter, Dennis C.; Mumma, Michael J.; Storrs, Alex D.
1991-01-01
Near-infrared spectroscopic observations of the active star-forming region near NGC 7538 IRS 1 and IRS 2 were made. The relative intensities of the v = 1-0 Q(1), Q(3), and Q(5) lines of molecular hydrogen are used to calculate a rotational excitation temperature. Comparison of the measured intensity of the Q(2) transition relative to the intensity of Q(1) and Q(3) permitted the retrieval of the ratio of ortho-to-para hydrogen. It is found that an ortho-to-para ratio of between 1.6 and 2.35 is needed to explain the Q-branch line intensity ratios, depending on the excitation model used. This range in ortho-to-para ratios implies a range of molecular hydrogen formation temperature of approximately 105 K to 140 K.
Multi-wavelength mid-IR light source for gas sensing
NASA Astrophysics Data System (ADS)
Karioja, Pentti; Alajoki, Teemu; Cherchi, Matteo; Ollila, Jyrki; Harjanne, Mikko; Heinilehto, Noora; Suomalainen, Soile; Viheriälä, Jukka; Zia, Nouman; Guina, Mircea; Buczyński, Ryszard; Kasztelanic, Rafał; Kujawa, Ireneusz; Salo, Tomi; Virtanen, Sami; Kluczyński, Paweł; Sagberg, Hâkon; Ratajczyk, Marcin; Kalinowski, Przemyslaw
2017-02-01
Cost effective multi-wavelength light sources are key enablers for wide-scale penetration of gas sensors at Mid-IR wavelength range. Utilizing novel Mid-IR Si-based photonic integrated circuits (PICs) filter and wide-band Mid-IR Super Luminescent Light Emitting Diodes (SLEDs), we show the concept of a light source that covers 2.5…3.5 μm wavelength range with a resolution of <1nm. The spectral bands are switchable and tunable and they can be modulated. The source allows for the fabrication of an affordable multi-band gas sensor with good selectivity and sensitivity. The unit price can be lowered in high volumes by utilizing tailored molded IR lens technology and automated packaging and assembling technologies. The status of the development of the key components of the light source are reported. The PIC is based on the use of micron-scale SOI technology, SLED is based on AlGaInAsSb materials and the lenses are tailored heavy metal oxide glasses fabricated by the use of hot-embossing. The packaging concept utilizing automated assembly tools is depicted. In safety and security applications, the Mid-IR wavelength range covered by the novel light source allows for detecting several harmful gas components with a single sensor. At the moment, affordable sources are not available. The market impact is expected to be disruptive, since the devices currently in the market are either complicated, expensive and heavy instruments, or the applied measurement principles are inadequate in terms of stability and selectivity.
Coleman, Sylvester; Dadzie, Samuel K; Seyoum, Aklilu; Yihdego, Yemane; Mumba, Peter; Dengela, Dereje; Ricks, Philip; George, Kristen; Fornadel, Christen; Szumlas, Daniel; Psychas, Paul; Williams, Jacob; Appawu, Maxwell A; Boakye, Daniel A
2017-08-10
Indoor residual spraying (IRS) is being implemented as one of the malaria prevention methods in the Northern Region of Ghana. Changes in longevity, sporozoite and entomological inoculation rates (EIRs) of major malaria vectors were monitored to assess the impact of IRS in selected districts. Monthly human landing catches (HLCs) were used to collect mosquitoes from sentinel sites in three adjacent districts between July 2009 and December 2014: Savelugu Nanton (SND) where IRS had been implemented from 2008 to 2014; Tolon Kumbungu (TKD) where IRS had been implemented between 2008 and 2012 and Tamale Metropolis (TML) with no history of IRS. Mosquitoes were morphologically identified to species level and into sibling species, using PCR. Samples of Anopheles gambiae sensu lato (s.l.) were examined for parity and infectivity. EIR was calculated from biting and infectivity rates of malaria vectors. Parity rates of An. gambiae s.l. decreased significantly (p < 0.0001) in SND from 44.8% in 2011 to 28.1% by 2014, and in TKD from 53.3% in 2011 to 46.6% in 2012 (p = 0.001). However 2 years after IRS was discontinued in TKD, the proportion of parous An. gambiae s.l. increased significantly to 68.5% in 2014 (p < 0.0001). Parity rates in the unsprayed district remained high throughout the study period, ranging between 68.6% in 2011 and 72.3% in 2014. The sum of monthly EIRs post-IRS season (July-December) in SND ranged between 2.1 and 6.3 infective bites/person/season (ib/p/s) during the 3 years that the district was sprayed with alphacypermethrin. EIR in SND was reduced to undetectable levels when the insecticide was switched to pirimiphos methyl CS in 2013 and 2014. Two years after IRS was withdrawn from TKD the sum of monthly EIRs (July-December) increased by about fourfold from 41.8 ib/p/s in 2012 to 154.4 ib/p/s in 2014. The EIR in the control area, TML, ranged between 35 ib/p/s in 2009 to 104.71 ib/p/s by 2014. This study demonstrates that IRS application did have a significant impact on entomological indicators of malaria transmission in the IRS project districts of Northern Ghana. Transmission indicators increased following the withdrawal of IRS from Tolon Kumbungu District.
Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber.
Lee, Bongsoo; Shin, Sang Hun; Jang, Kyoung Won; Yoo, Wook Jae
2015-05-11
In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD) based on a BCF-12 as a plastic scintillating fiber (PSF) and a fiber-optic thermometer (FOT) using a silver halide optical fiber as an infrared optical fiber (IR fiber). During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of -0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber.
Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber
Lee, Bongsoo; Shin, Sang Hun; Jang, Kyoung Won; Yoo, Wook Jae
2015-01-01
In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD) based on a BCF-12 as a plastic scintillating fiber (PSF) and a fiber-optic thermometer (FOT) using a silver halide optical fiber as an infrared optical fiber (IR fiber). During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of −0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber. PMID:25970257
Dengela, Dereje; Seyoum, Aklilu; Lucas, Bradford; Johns, Benjamin; George, Kristen; Belemvire, Allison; Caranci, Angela; Norris, Laura C; Fornadel, Christen M
2018-01-30
Indoor residual spraying (IRS) is the application of insecticide to the interior walls of household structures that often serve as resting sites for mosquito vectors of malaria. Human exposure to malaria vectors is reduced when IRS involves proper application of pre-determined concentrations of the active ingredient specific to the insecticide formulation of choice. The impact of IRS can be affected by the dosage of insecticide, spray coverage, vector behavior, vector susceptibility to insecticides, and the residual efficacy of the insecticide applied. This report compiles data on the residual efficacy of insecticides used in IRS campaigns implemented by the United States President's Malaria Initiative (PMI)/United States Agency for International Development (USAID) in 17 African countries and compares observed length of efficacy to ranges proposed in World Health Organization (WHO) guidelines. Additionally, this study provides initial analysis on variation of mosquito mortality depending on the surface material of sprayed structures, country spray program, year of implementation, source of tested mosquitoes, and type of insecticide. Residual efficacy of the insecticides used for PMI/USAID-supported IRS campaigns was measured in Benin, Burkina Faso, Ethiopia, Ghana, Kenya, Liberia, Madagascar, Malawi, Mali, Mozambique, Nigeria, Rwanda, Senegal, Tanzania, Uganda, Zambia and Zimbabwe. The WHO cone bioassay tests were used to assess the mortality rate of mosquitoes exposed to insecticide-treated mud, wood, cement, and other commonly used housing materials. Baseline tests were performed within weeks of IRS application and follow-up tests were continued until the mortality of exposed mosquitoes dropped below 80% or the program monitoring period ended. Residual efficacy in months was then evaluated with respect to WHO guidelines that provide suggested ranges of residual efficacy for insecticide formulations recommended for use in IRS. Where the data allowed, direct comparisons of mosquito mortality rates were then made to determine any significant differences when comparing insecticide formulation, country, year, surface type, and the source of the mosquitoes used in testing. The residual efficacy of alpha-cypermethrin ranged from 4 to 10 months (average = 6.4 months), with no reported incidents of underperformance when compared to the efficacy range provided in WHO guidelines. Deltamethrin residual efficacy results reported a range of 1 to 10 months (average = 4.9 months), with two instances of underperformance. The residual efficacy of bendiocarb ranged from 2 weeks to 7 months (average = 2.8 months) and failed to achieve proposed minimum efficacy on 14 occasions. Lastly, long-lasting pirimiphos-methyl efficacy ranged from 2 months to 9 months (average = 5.3 months), but reported 13 incidents of underperformance. Much of the data used to determine application rate and expected efficacy of insecticides approved for use in IRS programs are collected in controlled laboratory or pilot field studies. However, the generalizability of the results obtained under controlled conditions are limited and unlikely to account for variation in locally sourced housing materials, climate, and the myriad other factors that may influence the bio-efficacy of insecticides. Here, data are presented that confirm the variation in residual efficacy observed when monitoring household surfaces sprayed during PMI/USAID-supported IRS campaigns. All insecticides except alpha-cypermethrin showed evidence of failing to meet the minimum range of residual efficacy proposed in WHO criteria at least once. However, this initial effort in characterizing program-wide insecticide bio-efficacy indicates that some insecticides, such as bendiocarb and pirimiphos-methyl, may be vulnerable to variations in the local environment. Additionally, the comparative analysis performed in this study provides evidence that mosquito mortality rates differ with respect to factors including: the types of insecticide sprayed, surface material, geographical location, year of spraying, and tested mosquitoes. It is, therefore, important to locally assess the residual efficacy of insecticides on various surfaces to inform IRS programming.
Multiple-frame IR photo-recorder KIT-3M
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roos, E; Wilkins, P; Nebeker, N
2006-05-15
This paper reports the experimental results of a high-speed multi-frame infrared camera which has been developed in Sarov at VNIIEF. Earlier [1] we discussed the possibility of creation of the multi-frame infrared radiation photo-recorder with framing frequency about 1 MHz. The basis of the photo-recorder is a semiconductor ionization camera [2, 3], which converts IR radiation of spectral range 1-10 micrometers into a visible image. Several sequential thermal images are registered by using the IR converter in conjunction with a multi-frame electron-optical camera. In the present report we discuss the performance characteristics of a prototype commercial 9-frame high-speed IR photo-recorder.more » The image converter records infrared images of thermal fields corresponding to temperatures ranging from 300 C to 2000 C with an exposure time of 1-20 {micro}s at a frame frequency up to 500 KHz. The IR-photo-recorder camera is useful for recording the time evolution of thermal fields in fast processes such as gas dynamics, ballistics, pulsed welding, thermal processing, automotive industry, aircraft construction, in pulsed-power electric experiments, and for the measurement of spatial mode characteristics of IR-laser radiation.« less
Modeling Infrared Signal Reflections to Characterize Indoor Multipath Propagation
De-La-Llana-Calvo, Álvaro; Lázaro-Galilea, José Luis; Gardel-Vicente, Alfredo; Rodríguez-Navarro, David; Bravo-Muñoz, Ignacio; Tsirigotis, Georgios; Iglesias-Miguel, Juan
2017-01-01
In this paper, we propose a model to characterize Infrared (IR) signal reflections on any kind of surface material, together with a simplified procedure to compute the model parameters. The model works within the framework of Local Positioning Systems (LPS) based on IR signals (IR-LPS) to evaluate the behavior of transmitted signal Multipaths (MP), which are the main cause of error in IR-LPS, and makes several contributions to mitigation methods. Current methods are based on physics, optics, geometry and empirical methods, but these do not meet our requirements because of the need to apply several different restrictions and employ complex tools. We propose a simplified model based on only two reflection components, together with a method for determining the model parameters based on 12 empirical measurements that are easily performed in the real environment where the IR-LPS is being applied. Our experimental results show that the model provides a comprehensive solution to the real behavior of IR MP, yielding small errors when comparing real and modeled data (the mean error ranges from 1% to 4% depending on the environment surface materials). Other state-of-the-art methods yielded mean errors ranging from 15% to 40% in test measurements. PMID:28406436
Liu, Sibao; Dutta, Saikat; Zheng, Weiqing; Gould, Nicholas S; Cheng, Ziwei; Xu, Bingjun; Saha, Basudeb; Vlachos, Dionisios G
2017-08-24
Renewable jet-fuel-range alkanes are synthesized by hydrodeoxygenation of lignocellulose-derived high-carbon furylmethanes over ReO x -modified Ir/SiO 2 catalysts under mild reaction conditions. Ir-ReO x /SiO 2 with a Re/Ir molar ratio of 2:1 exhibits the best performance, achieving a combined alkanes yield of 82-99 % from C 12 -C 15 furylmethanes. The catalyst can be regenerated in three consecutive cycles with only about 12 % loss in the combined alkanes yield. Mechanistically, the furan moieties of furylmethanes undergo simultaneous ring saturation and ring opening to form a mixture of complex oxygenates consisting of saturated furan rings, mono-keto groups, and mono-hydroxy groups. Then, these oxygenates undergo a cascade of hydrogenolysis reactions to alkanes. The high activity of Ir-ReO x /SiO 2 arises from a synergy between Ir and ReO x , whereby the acidic sites of partially reduced ReO x activate the C-O bonds of the saturated furans and alcoholic groups while the Ir sites are responsible for hydrogenation with H 2 . © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Long range thermal weapon sights for the German future infantryman program IdZ
NASA Astrophysics Data System (ADS)
Breiter, Rainer; Ihle, Tobias; Mauk, Karl-Heinz; Münzberg, Mario; Rode, Werner
2007-04-01
In December 2004 AIM started the series production of the HuntIR long range thermal weapon sight. The sight is fielded in the Germany Future Infantryman (IdZ) basic system and since that time in continuous service in various out of area missions with German participation. For very long identification ranges >1500m cooled technology still outperforms uncooled sights, even with respect to smaller size and lower weight because the typical F/1 design of uncooled systems overcompensates cooler weight for focal length >175mm. The HuntIR sight is therefore based on a cooled MWIR detection module for long range battlefield surveillance and target engagement. The device specifically is a perfect match to state of the art small arms like 0.50 cal sniper rifles or crew served weapons like the 40mm high velocity grenade machine gun (GMG) which provide engagement ranges >1500m and need an adequate sight performance beyond that. A recent modification of HuntIR was done to provide a wider field of view for improved situation awareness in urban operations and specifically to allow the engagement of the 40mm GMG in ranges between 250-1200m. The qualification tests of the sight by the German infantry were successfully completed mid 2006. To match the demand of the follow-up program IdZ-ES additional components have to be integrated. Most important are a laser range finder (LRF), 3 axis digital magnetic compass (DMC) and a wireless data link. LRF and DMC together with a highly sophisticated fire control computer provide improved first round hit probability, the DMC additionally improves the fire control in any case of steep trajectories or for pronounced ballistic trajectories to avoid any need to precisely level the GMG. This new sight is done under the brand name RangIR. An important additional feature is the interface for air burst ammunition (ABM). The optical distance is measured by the LRF, the fire control computer accurately evaluates the trajectory under the given angle, muzzle velocity, temperature and range conditions to define the time-of-flight. This fully integrated IR fire control system is available mid 2007. The development phase of the IdZES program is under contract, series deliveries expected in 2009. The RangIR will see some specific modifications for the link and a man machine interface to control the whole IdZ-ES system components ergonomically from the weapon with optimized power supply concepts to minimize the number of batteries, chargers etc.
AFM-IR: Technology and Applications in Nanoscale Infrared Spectroscopy and Chemical Imaging.
Dazzi, Alexandre; Prater, Craig B
2016-12-13
Atomic force microscopy-based infrared spectroscopy (AFM-IR) is a rapidly emerging technique that provides chemical analysis and compositional mapping with spatial resolution far below conventional optical diffraction limits. AFM-IR works by using the tip of an AFM probe to locally detect thermal expansion in a sample resulting from absorption of infrared radiation. AFM-IR thus can provide the spatial resolution of AFM in combination with the chemical analysis and compositional imaging capabilities of infrared spectroscopy. This article briefly reviews the development and underlying technology of AFM-IR, including recent advances, and then surveys a wide range of applications and investigations using AFM-IR. AFM-IR applications that will be discussed include those in polymers, life sciences, photonics, solar cells, semiconductors, pharmaceuticals, and cultural heritage. In the Supporting Information , the authors provide a theoretical section that reviews the physics underlying the AFM-IR measurement and detection mechanisms.
Discrimination of wild-growing and cultivated Lentinus edodes by tri-step infrared spectroscopy
NASA Astrophysics Data System (ADS)
Lin, Haojian; Liu, Gang; Yang, Weimei; An, Ran; Ou, Quanhong
2018-01-01
It's not easy to discriminate dried wild-growing Lentinus edodes (WL) and cultivated Lentinus edodes (CL) by conventional method based on the morphological inspection of fruiting bodies. In this paper, fruiting body samples of WL and CL are discriminated by a tri-step IR spectroscopy method, including Fourier transform infrared (FT-IR) spectroscopy, second derivatives infrared (SD-IR) spectroscopy and two-dimensional correlation infrared (2D-IR) spectroscopy under thermal perturbation. The results show that the FT-IR spectra of WL and CL are similar in holistic spectral profile. More significant differences are exhibited in their SD-IR spectra in the range of 1700 - 900 cm-1. Furthermore, more evident differences have been observed in their synchronous 2D-IR spectra in the range of 2970 - 2900, 1678 - 1390, 1250 -1104 and 1090 - 1030 cm-1. The CL has thirteen auto-peaks at 2958, 2921, 1649, 1563, 1450, 1218, 1192, 1161, 1140, 1110, 1082, 1065 and 1047 cm-1, in which the four strongest auto-peaks are at 2921, 1563, 1192 and 1082 cm-1. The WL shows fifteen auto-peaks at 2960, 2937, 2921, 1650, 1615, 1555, 1458, 1219, 1190, 1138, 1111, 1084, 1068, 1048 and 1033 cm-1, in which the four strongest auto-peaks are at 2921, 1650, 1190 and 1068 cm-1. This study shows the potential of FT-IR spectroscopy and 2D correlation analysis in a simple and quick distinction of wild-growing and cultivated mushrooms.
Infrared radiation from hot cones on cool conifers attracts seed-feeding insects
Takács, Stephen; Bottomley, Hannah; Andreller, Iisak; Zaradnik, Tracy; Schwarz, Joseph; Bennett, Robb; Strong, Ward; Gries, Gerhard
2008-01-01
Foraging animals use diverse cues to locate resources. Common foraging cues have visual, auditory, olfactory, tactile or gustatory characteristics. Here, we show a foraging herbivore using infrared (IR) radiation from living plants as a host-finding cue. We present data revealing that (i) conifer cones are warmer and emit more near-, mid- and long-range IR radiation than needles, (ii) cone-feeding western conifer seed bugs, Leptoglossus occidentalis (Hemiptera: Coreidae), possess IR receptive organs and orient towards experimental IR cues, and (iii) occlusion of the insects' IR receptors impairs IR perception. The conifers' cost of attracting cone-feeding insects may be offset by occasional mast seeding resulting in cone crops too large to be effectively exploited by herbivores. PMID:18945664
Infrared radiation from hot cones on cool conifers attracts seed-feeding insects.
Takács, Stephen; Bottomley, Hannah; Andreller, Iisak; Zaradnik, Tracy; Schwarz, Joseph; Bennett, Robb; Strong, Ward; Gries, Gerhard
2009-02-22
Foraging animals use diverse cues to locate resources. Common foraging cues have visual, auditory, olfactory, tactile or gustatory characteristics. Here, we show a foraging herbivore using infrared (IR) radiation from living plants as a host-finding cue. We present data revealing that (i) conifer cones are warmer and emit more near-, mid- and long-range IR radiation than needles, (ii) cone-feeding western conifer seed bugs, Leptoglossus occidentalis (Hemiptera: Coreidae), possess IR receptive organs and orient towards experimental IR cues, and (iii) occlusion of the insects' IR receptors impairs IR perception. The conifers' cost of attracting cone-feeding insects may be offset by occasional mast seeding resulting in cone crops too large to be effectively exploited by herbivores.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Wilcoxon-Mann-Whitney Test (a) When n and m are less than 21, use Table 1. In order to find the appropriate... trigger (Step 3). The interquartile range (R) is the difference between the quartiles M-1 and M1; these... baseline observations were obtained, calculate the median (M) of all baseline observations: Instructions...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Wilcoxon-Mann-Whitney Test (a) When n and m are less than 21, use Table 1. In order to find the appropriate... trigger (Step 3). The interquartile range (R) is the difference between the quartiles M-1 and M1; these... baseline observations were obtained, calculate the median (M) of all baseline observations: Instructions...
NASA Astrophysics Data System (ADS)
Shang, T.; Yang, H. L.; Zhan, Q. F.; Zuo, Z. H.; Xie, Y. L.; Liu, L. P.; Zhang, S. L.; Zhang, Y.; Li, H. H.; Wang, B. M.; Wu, Y. H.; Zhang, S.; Li, Run-Wei
2016-10-01
We report an investigation of anomalous-Hall resistance (AHR) and spin-Hall magnetoresistance (SMR) in Pt/Ir20Mn80/Y3Fe5O12 (Pt/IrMn/YIG) heterostructures. The AHR of Pt/IrMn/YIG heterostructures with an antiferromagnetic inserted layer is dramatically enhanced as compared to that of the Pt/YIG bilayer. The temperature dependent AHR behavior is nontrivial, while the IrMn thickness dependent AHR displays a peak at an IrMn thickness of 3 nm. The observed SMR in the temperature range of 10-300 K indicates that the spin current generated in the Pt layer can penetrate the IrMn layer (≤3 nm) to interact with the ferromagnetic YIG layer. The lack of conventional anisotropic magnetoresistance (AMR) implies that the insertion of the IrMn layer between Pt and YIG could efficiently suppress the magnetic proximity effect (MPE) on induced Pt moments by YIG.
NASA Astrophysics Data System (ADS)
Jin, Chengzhi; Liu, Jiangping; Chen, Yu; Guan, Ruilin; Ouyang, Cheng; Zhu, Yanjiao; Ji, Liangnian; Chao, Hui
2016-02-01
Mitophagy, which is a special autophagy that removes damaging mitochondria to maintain sufficient healthy mitochondria, provides an alternative path for addressing dysfunctional mitochondria and avoiding cellular death. In the present study, by coupling the triphenylamine group with 2-phenylimidazo[4,5-f][1,10]phenanthroline derivatives, we synthesized five Ir(III) complexes with an AIE property that are expected to fulfill requirements for real-time monitoring of mitophagy. Ir1-Ir5 were exploited to image mitochondria with a short incubation time by confocal microscopy and inductive coupled plasma-mass spectrometry (ICP-MS). Due to aggregation-induced emission (AIE), Ir1-Ir5 exhibited excellent photostability compared to MitoTracker Green (MTG). Moreover, Ir1-Ir5 manifested satisfactory photostability in the mitochondrial physiological pH range. In addition, the uptake mechanism of Ir1 was investigated using confocal microscopy and flow cytometry analysis. Finally, using both Ir1 and LysoTracker Green, we were able to achieve real-time monitoring of mitophagy.
An Initial Evaluation of the Impact of Pokémon GO on Physical Activity.
Xian, Ying; Xu, Hanzhang; Xu, Haolin; Liang, Li; Hernandez, Adrian F; Wang, Tracy Y; Peterson, Eric D
2017-05-16
Pokémon GO is a location-based augmented reality game. Using GPS and the camera on a smartphone, the game requires players to travel in real world to capture animated creatures, called Pokémon. We examined the impact of Pokémon GO on physical activity (PA). A pre-post observational study of 167 Pokémon GO players who were self-enrolled through recruitment flyers or online social media was performed. Participants were instructed to provide screenshots of their step counts recorded by the iPhone Health app between June 15 and July 31, 2016, which was 3 weeks before and 3 weeks after the Pokémon GO release date. Of 167 participants, the median age was 25 years (interquartile range, 21-29 years). The daily average steps of participants at baseline was 5678 (SD, 2833; median, 5718 [interquartile range, 3675-7279]). After initiation of Pokémon GO, daily activity rose to 7654 steps (SD, 3616; median, 7232 [interquartile range, 5041-9744], pre-post change: 1976; 95% CI, 1494-2458, or a 34.8% relative increase [ P <0.001]). On average, 10 000 "XP" points (a measure of game progression) was associated with 2134 additional steps per day (95% CI, 1673-2595), suggesting a potential dose-response relationship. The number of participants achieving a goal of 10 000+ steps per day increased from 15.3% before to 27.5% after (odds ratio, 2.06; 95% CI, 1.70-2.50). Increased PA was also observed in subgroups, with the largest increases seen in participants who spent more time playing Pokémon GO, those who were overweight/obese, or those with a lower baseline PA level. Pokémon GO participation was associated with a significant increase in PA among young adults. Incorporating PA into gameplay may provide an alternative way to promote PA in persons who are attracted to the game. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02888314. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Patel, Priyesh A; Liang, Li; Khazanie, Prateeti; Hammill, Bradley G; Fonarow, Gregg C; Yancy, Clyde W; Bhatt, Deepak L; Curtis, Lesley H; Hernandez, Adrian F
2016-07-01
Diabetes mellitus, heart failure (HF), and chronic kidney disease are common comorbidities, but overall use and safety of antihyperglycemic medications (AHMs) among patients with these comorbidities are poorly understood. Using Get With the Guidelines-Heart Failure and linked Medicare Part D data, we assessed AHM use within 90 days of hospital discharge among HF patients with diabetes mellitus discharged from Get With the Guidelines-Heart Failure hospitals between January 1, 2006, and October 1, 2011. We further summarized use by renal function and assessed renal contraindicated AHM use for patients with estimated glomerular filtration rate <30 mL/min/1.73m(2). Among 8791 patients meeting inclusion criteria, the median age was 77 (interquartile range 71-83), 62.3% were female, median body mass index was 29.7 (interquartile range 25.5-35.3), median hemoglobin A1c was 6.8 (interquartile range 6.2-7.8), and 34% had ejection fraction <40%. 74.9% of patients filled a prescription for an AHM, with insulin (39.5%), sulfonylureas (32.4%), and metformin (17%) being the most commonly used AHMs. Insulin use was higher and sulfonylurea/metformin use was lower among patients with lower renal function classes. Among 1512 patients with estimated glomerular filtration rate <30 mL/min/1.73m(2), 35.4% filled prescriptions for renal contraindicated AHMs per prescribing information, though there was a trend toward lower renal contraindicated AHM use over time (Cochran-Mantel-Haenszel row-mean score test P=0.048). Although use of other AHMs was low overall, thiazolidinediones were used in 6.6% of HF patients, and dipeptidyl peptidase-4 inhibitors were used in 5.1%, with trends for decreasing thiazolidinedione use and increased dipeptidyl peptidase-4 inhibitor use over time (P<0.001). Treatment of diabetes mellitus in patients with HF and chronic kidney disease is complex, and these patients are commonly treated with renal contraindicated AHMs, including over 6% receiving a thiazolidinedione, despite known concerns regarding HF. More research regarding safety and efficacy of various AHMs among HF patients is needed. © 2016 American Heart Association, Inc.
Poeran, Jashvant; Mazumdar, Madhu; Rasul, Rehana; Meyer, Joanne; Sacks, Henry S; Koll, Brian S; Wallach, Frances R; Moskowitz, Alan; Gelijns, Annetine C
2016-02-01
Antibiotic use, particularly type and duration, is a crucial modifiable risk factor for Clostridium difficile. Cardiac surgery is of particular interest because prophylactic antibiotics are recommended for 48 hours or less (vs ≤24 hours for noncardiac surgery), with increasing vancomycin use. We aimed to study associations between antibiotic prophylaxis (duration/vancomycin use) and C difficile among patients undergoing coronary artery bypass grafting. We extracted data on coronary artery bypass grafting procedures from the national Premier Perspective claims database (2006-2013, n = 154,200, 233 hospitals). Multilevel multivariable logistic regressions measured associations between (1) duration (<2 days, "standard" vs ≥2 days, "extended") and (2) type of antibiotic used ("cephalosporin," "cephalosporin + vancomycin," "vancomycin") and C difficile as outcome. Overall C difficile prevalence was 0.21% (n = 329). Most patients (59.7%) received a cephalosporin only; in 33.1% vancomycin was added, whereas 7.2% received vancomycin only. Extended prophylaxis was used in 20.9%. In adjusted analyses, extended prophylaxis (vs standard) was associated with significantly increased C difficile risk (odds ratio, 1.43; confidence interval, 1.07-1.92), whereas no significant associations existed for vancomycin use as adjuvant or primary prophylactic compared with the use of cephalosporins (odds ratio, 1.21; confidence interval, 0.92-1.60, and odds ratio, 1.39; confidence interval, 0.94-2.05, respectively). Substantial inter-hospital variation exists in the percentage of extended antibiotic prophylaxis (interquartile range, 2.5-35.7), use of adjuvant vancomycin (interquartile range, 4.2-61.1), and vancomycin alone (interquartile range, 2.3-10.4). Although extended use of antibiotic prophylaxis was associated with increased C difficile risk after coronary artery bypass grafting, vancomycin use was not. The observed hospital variation in antibiotic prophylaxis practices suggests great potential for efforts aimed at standardizing practices that subsequently could reduce C difficile risk. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Zifan, Ali; Ledgerwood-Lee, Melissa; Mittal, Ravinder K
2016-12-01
Three-dimensional high-definition anorectal manometry (3D-HDAM) is used to assess anal sphincter function; it determines profiles of regional pressure distribution along the length and circumference of the anal canal. There is no consensus, however, on the best way to analyze data from 3D-HDAM to distinguish healthy individuals from persons with sphincter dysfunction. We developed a computer analysis system to analyze 3D-HDAM data and to aid in the diagnosis and assessment of patients with fecal incontinence (FI). In a prospective study, we performed 3D-HDAM analysis of 24 asymptomatic healthy subjects (control subjects; all women; mean age, 39 ± 10 years) and 24 patients with symptoms of FI (all women; mean age, 58 ± 13 years). Patients completed a standardized questionnaire (FI severity index) to score the severity of FI symptoms. We developed and evaluated a robust prediction model to distinguish patients with FI from control subjects using linear discriminant, quadratic discriminant, and logistic regression analyses. In addition to collecting pressure information from the HDAM data, we assessed regional features based on shape characteristics and the anal sphincter pressure symmetry index. The combination of pressure values, anal sphincter area, and reflective symmetry values was identified in patients with FI versus control subjects with an area under the curve value of 1.0. In logistic regression analyses using different predictors, the model identified patients with FI with an area under the curve value of 0.96 (interquartile range, 0.22). In discriminant analysis, results were classified with a minimum error of 0.02, calculated using 10-fold cross-validation; different combinations of predictors produced median classification errors of 0.16 in linear discriminant analysis (interquartile range, 0.25) and 0.08 in quadratic discriminant analysis (interquartile range, 0.25). We developed and validated a novel prediction model to analyze 3D-HDAM data. This system can accurately distinguish patients with FI from control subjects. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.
Gao, S; Sun, F-K; Fan, Y-C; Shi, C-H; Zhang, Z-H; Wang, L-Y; Wang, K
2015-08-01
Glutathione-S-transferase P1 (GSTP1) methylation has been demonstrated to be associated with oxidative stress induced liver damage in acute-on-chronic hepatitis B liver failure (ACHBLF). To evaluate the methylation level of GSTP1 promoter in acute-on-chronic hepatitis B liver failure and determine its predictive value for prognosis. One hundred and five patients with acute-on-chronic hepatitis B liver failure, 86 with chronic hepatitis B (CHB) and 30 healthy controls (HC) were retrospectively enrolled. GSTP1 methylation level in peripheral mononuclear cells (PBMC) was detected by MethyLight. Clinical and laboratory parameters were obtained. GSTP1 methylation levels were significantly higher in patients with acute-on-chronic hepatitis B liver failure (median 16.84%, interquartile range 1.83-59.05%) than those with CHB (median 1.25%, interquartile range 0.48-2.47%; P < 0.01) and HC (median 0.80%, interquartile range 0.67-1.27%; P < 0.01). In acute-on-chronic hepatitis B liver failure group, nonsurvivors showed significantly higher GSTP1 methylation levels (P < 0.05) than survivors. GSTP1 methylation level was significantly correlated with total bilirubin (r = 0.29, P < 0.01), prothrombin time activity (r = -0.24, P = 0.01) and model for end-stage liver disease (MELD) score (r = 0.26, P = 0.01). When used to predict 1- or 2-month mortality of acute-on-chronic hepatitis B liver failure, GSTP1 methylation showed significantly better predictive value than MELD score [area under the receiver operating characteristic curve (AUC) 0.89 vs. 0.72, P < 0.01; AUC 0.83 vs. 0.70, P < 0.05 respectively]. Meanwhile, patients with GSTP1 methylation levels above the cut-off points showed significantly poorer survival than those below (P < 0.05). Aberrant GSTP1 promoter methylation exists in acute-on-chronic hepatitis B liver failure and shows high predictive value for short-term mortality. It might serve as a potential prognostic marker for acute-on-chronic hepatitis B liver failure. © 2015 John Wiley & Sons Ltd.
Gupta, Mihir; Miller, Christopher J; Baker, Jason V; Lazar, Jason; Bogner, Johannes R; Calmy, Alexandra; Soliman, Elsayed Z; Neaton, James D
2013-03-01
We assessed the relation of inflammatory and coagulation biomarkers with electrocardiographic (ECG) evidence of myocardial ischemia. High-sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), and D-dimer levels were measured at study entry for 3,085 human immunodeficiency virus-infected participants (mean age 44 years; 26.4% women; 24.6% black) in the Strategies for Management of Antiretroviral Therapy trial. Logistic regression models were used to examine the associations of these biomarkers with prevalent and incident myocardial ischemia. The latter analyses were performed for 1,411 participants who were randomly assigned to receive continuous antiretroviral therapy during follow-up to suppress the human immunodeficiency virus viral load and had ≥1 ECG reading during the follow-up period. The median hsCRP, IL-6, and D-dimer level was 1.65 μg/ml (interquartile range 0.69 to 4.11), 1.60 pg/ml (interquartile range 1.00 to 2.75), and 0.18 μg/ml (interquartile range 0.11 to 0.32), respectively. At baseline, the prevalence of major or minor Q-QS or ST-T ECG abnormalities was 18.6%. The biomarker levels were associated with prevalent major or minor ischemic abnormalities on the univariate analyses; however, adjustment for traditional risk factors attenuated these associations. The adjusted odds ratio for major or minor ischemic abnormalities and 95% confidence intervals for the greatest versus lowest quartiles was 1.3 (95% confidence interval 0.9 to 1.7) for hsCRP, 1.0 (95% confidence interval 0.7 to 1.3) for IL-6, and 1.1 (95% confidence interval 0.9 to 1.5) for D-dimer. During a median follow-up of 2.3 years, new definite or probable ischemic ECG abnormalities developed in 11.7% of participants receiving continuous antiretroviral therapy. Biomarker levels were not associated with incident abnormalities on unadjusted or adjusted analyses. In conclusion, higher levels of hsCRP, IL-6, and D-dimer were not associated with ischemic ECG abnormalities. Elevated biomarker levels and ECG abnormalities indicating myocardial ischemia might reflect different risk pathways for cardiovascular disease. Copyright © 2013 Elsevier Inc. All rights reserved.
Li, Debbie; Baxter, Nancy N; McLeod, Robin S; Moineddin, Rahim; Wilton, Andrew S; Nathens, Avery B
2014-12-01
There is increasing evidence to support the use of percutaneous abscess drainage, laparoscopy, and primary anastomosis in managing acute diverticulitis. The aim of this study was to evaluate how practices have evolved and to determine the effects on clinical outcomes. This is a population-based retrospective cohort study using administrative discharge data. This study was conducted in Ontario, Canada. All patients had been hospitalized for a first episode of acute diverticulitis (2002-2012). Temporal changes in treatment strategies and outcomes were evaluated by using the Cochran-Armitage test for trends. Multivariable logistic regression with generalized estimating equations was used to test for trends while adjusting for patient characteristics. There were 18,543 patients hospitalized with a first episode of diverticulitis, median age 60 years (interquartile range, 48-74). From 2002 to 2012, there was an increase in the proportion of patients admitted with complicated disease (abscess, perforation), 32% to 38%, yet a smaller proportion underwent urgent operation, 28% to 16% (all p < 0.001). The use of percutaneous drainage increased from 1.9% of admissions in 2002 to 3.3% in 2012 (p < 0.001). After adjusting for changes in patient and disease characteristics over time, the odds of urgent operation decreased by 0.87 per annum (95% CI, 0.85-0.89). In those undergoing urgent surgery (n = 3873), the use of laparoscopy increased (9% to 18%, p <0.001), whereas the use of the Hartmann procedure remained unchanged (64%). During this time, in-hospital mortality decreased (2.7% to 1.9%), as did the median length of stay (5 days, interquartile range, 3-9; to 3 days, interquartile range, 2-6; p <0.001). There is the potential for residual confounding, because clinical parameters available for risk adjustment were limited to fields existing within administrative data. There has been an increase in the use of nonoperative and minimally invasive strategies in treating patients with a first episode of acute diverticulitis. However, the Hartmann procedure remains the most frequently used urgent operative approach. Mortality and length of stay have improved during this time.
Al Jaaly, Emad; Fiorentino, Francesca; Reeves, Barnaby C; Ind, Philip W; Angelini, Gianni D; Kemp, Scott; Shiner, Robert J
2013-10-01
We compared the efficacy of noninvasive ventilation with bilevel positive airway pressure added to usual care versus usual care alone in patients undergoing coronary artery bypass grafting. We performed a 2-group, parallel, randomized controlled trial. The primary outcome was time until fit for discharge. Secondary outcomes were partial pressure of carbon dioxide, forced expiratory volume in 1 second, atelectasis, adverse events, duration of intensive care stay, and actual postoperative stay. A total of 129 patients were randomly allocated to bilevel positive airway pressure (66) or usual care (63). Three patients allocated to bilevel positive airway pressure withdrew. The median duration of bilevel positive airway pressure was 16 hours (interquartile range, 11-19). The median duration of hospital stay until fit for discharge was 5 days for the bilevel positive airway pressure group (interquartile range, 4-6) and 6 days for the usual care group (interquartile range, 5-7; hazard ratio, 1.68; 95% confidence interval, 1.08-2.31; P = .019). There was no significant difference in duration of intensive care, actual postoperative stay, and mean percentage of predicted forced expiratory volume in 1 second on day 3. Mean partial pressure of carbon dioxide was significantly reduced 1 hour after bilevel positive airway pressure application, but there was no overall difference between the groups up to 24 hours. Basal atelectasis occurred in 15 patients (24%) in the usual care group and 2 patients (3%) in the bilevel positive airway pressure group. Overall, 30% of patients in the bilevel positive airway pressure group experienced an adverse event compared with 59% in the usual care group. Among patients undergoing elective coronary artery bypass grafting, the use of bilevel positive airway pressure at extubation reduced the recovery time. Supported by trained staff, more than 75% of all patients allocated to bilevel positive airway pressure tolerated it for more than 10 hours. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Gionfriddo, Ashley; Nonoyama, Mika L; Laussen, Peter C; Cox, Peter N; Clarke, Megan; Floh, Alejandro A
2018-06-01
To promote standardization, the Centers for Disease Control and Prevention introduced a new ventilator-associated pneumonia classification, which was modified for pediatrics (pediatric ventilator-associated pneumonia according to proposed criteria [PVAP]). We evaluated the frequency of PVAP in a cohort of children diagnosed with ventilator-associated pneumonia according to traditional criteria and compared their strength of association with clinically relevant outcomes. Retrospective cohort study. Tertiary care pediatric hospital. Critically ill children (0-18 yr) diagnosed with ventilator-associated pneumonia between January 2006 and December 2015 were identified from an infection control database. Patients were excluded if on high frequency ventilation, extracorporeal membrane oxygenation, or reintubated 24 hours following extubation. None. Patients were assessed for PVAP diagnosis. Primary outcome was the proportion of subjects diagnosed with PVAP. Secondary outcomes included association with intervals of care. Two hundred seventy-seven children who had been diagnosed with ventilator-associated pneumonia were eligible for review; 46 were excluded for being ventilated under 48 hours (n = 16), on high frequency ventilation (n = 12), on extracorporeal membrane oxygenation (n = 8), ineligible bacteria isolated from culture (n = 8), and other causes (n = 4). ICU admission diagnoses included congenital heart disease (47%), neurological (16%), trauma (7%), respiratory (7%), posttransplant (4%), neuromuscular (3%), and cardiomyopathy (3%). Only 16% of subjects (n = 45) met the new PVAP definition, with 18% (n = 49) having any ventilator-associated condition. Failure to fulfill new definitions was based on inadequate increase in mean airway pressure in 90% or FIO2 in 92%. PVAP was associated with prolonged ventilation (median [interquartile range], 29 d [13-51 d] vs 16 d [8-34.5 d]; p = 0.002), ICU (median [interquartile range], 40 d [20-100 d] vs 25 d [14-61 d]; p = 0.004) and hospital length of stay (median [interquartile range], 81 d [40-182 d] vs 54 d [31-108 d]; p = 0.04), and death (33% vs 16%; p = 0.008). Few children with ventilator-associated pneumonia diagnosis met the proposed PVAP criteria. PVAP was associated with increased morbidity and mortality. This work suggests that additional study is required before new definitions for ventilator-associated pneumonia are introduced for children.
Patient Advocacy Organizations, Industry Funding, and Conflicts of Interest.
Rose, Susannah L; Highland, Janelle; Karafa, Matthew T; Joffe, Steven
2017-03-01
Patient advocacy organizations (PAOs) are influential health care stakeholders that provide direct counseling and education for patients, engage in policy advocacy, and shape research agendas. Many PAOs report having financial relationships with for-profit industry, yet little is known about the nature of these relationships. To describe the nature of industry funding and partnerships between PAOs and for-profit companies in the United States. A survey was conducted from September 1, 2013, to June 30, 2014, of a nationally representative random sample of 439 PAO leaders, representing 5.6% of 7865 PAOs identified in the United States. Survey questions addressed the nature of their activities, their financial relationships with industry, and the perceived effectiveness of their conflict of interest policies. Amount and sources of revenue as well as organizational experiences with and policies regarding financial conflict of interest. Of the 439 surveys mailed to PAO leaders, 289 (65.8%) were returned with at least 80% of the questions answered. The PAOs varied widely in terms of size, funding, activities, and disease focus. The median total revenue among responding organizations was $299 140 (interquartile range, $70 000-$1 200 000). A total of 165 of 245 PAOs (67.3%) reported receiving industry funding, with 19 of 160 PAOs (11.9%) receiving more than half of their funding from industry. Among the subset of PAOs that received industry funding, the median amount was $50 000 (interquartile range, $15 000-$200 000); the median proportion of industry support derived from the pharmaceutical, device, and/or biotechnology sectors was 45% (interquartile range, 0%-100%). A total of 220 of 269 respondents (81.8%) indicated that conflicts of interest are very or moderately relevant to PAOs, and 94 of 171 (55.0%) believed that their organizations' conflict of interest policies were very good. A total of 22 of 285 PAO leaders (7.7%) perceived pressure to conform their positions to the interests of corporate donors. Patient advocacy organizations engage in wide-ranging health activities. Although most PAOs receive modest funding from industry, a minority receive substantial industry support, raising added concerns about independence. Many respondents report a need to improve their conflict of interest policies to help maintain public trust.
Choquette, Anne F.
2014-01-01
This report summarizes pesticide and nitrate (as nitrogen) results from quarterly sampling of 31 surficial-aquifer wells in the Lake Wales Ridge Monitoring Network during April 1999 through January 2005. The wells, located adjacent to citrus orchards and used for monitoring only, were generally screened (sampled) within 5 to 40 feet of the water table. Of the 44 citrus pesticides and pesticide degradates analyzed, 17 were detected in groundwater samples. Parent pesticides and degradates detected in quarterly groundwater samples, ordered by frequency of detection, included norflurazon, demethyl norflurazon, simazine, diuron, bromacil, aldicarb sulfone, aldicarb sulfoxide, deisopropylatrazine (DIA), imidacloprid, metalaxyl, thiazopyr monoacid, oxamyl, and aldicarb. Reconnaissance sampling of five Network wells yielded detection of four additional pesticide degradates (hydroxysimazine, didealkylatrazine, deisopropylhydroxyatrazine, and hydroxyatrazine). The highest median concentration values per well, based on samples collected during the 1999–2005 period (n=14 to 24 samples per well), included 3.05 µg/L (micrograms per liter) (simazine), 3.90 µg/L (diuron), 6.30 µg/L (aldicarb sulfone), 6.85 µg/L (aldicarb sulfoxide), 22.0 µg/L (demethyl norflurazon), 25.0 µg/ (norflurazon), 89 µg/ (bromacil), and 25.5 mg/L (milligrams per liter) (nitrate). Nitrate concentrations exceeded the 10 mg/L (as nitrogen) drinking water standard in one or more groundwater samples from 28 of the wells, and the median nitrate concentration among these wells was 14 mg/L. Sampled groundwater pesticide concentrations exceeded Florida’s health-guidance benchmarks for aldicarb sulfoxide and aldicarb sulfone (4 wells), the sum of aldicarb and its degradates (6 wells), simazine (2 wells), the sum of simazine and DIA (3 wells), diuron (2 wells), bromacil (1 well), and the sum of norflurazon and demethyl norflurazon (1 well). The magnitude of fluctuations in groundwater pesticide concentrations varied between wells and between pesticide compounds. Of the 10 pesticide compounds detected at sufficient frequency to assess temporal variability in quarterly sampling records, median values of the relative interquartile range (ratio of the interquartile range to the median) among wells typically ranged from about 100 to 150 percent. The relative interquartile range of pesticide concentrations at individual wells could be much higher, sometimes exceeding 200 to 500 percent. No distinct spatial patterns were apparent among median pesticide concentrations in sampled wells; nitrate concentrations tended to be greater in samples from wells in the northern part of the study area.
Pomytkin, Igor; Costa-Nunes, João P; Kasatkin, Vladimir; Veniaminova, Ekaterina; Demchenko, Anna; Lyundup, Alexey; Lesch, Klaus-Peter; Ponomarev, Eugene D; Strekalova, Tatyana
2018-04-24
While the insulin receptor (IR) was found in the CNS decades ago, the brain was long considered to be an insulin-insensitive organ. This view is currently revisited, given emerging evidence of critical roles of IR-mediated signaling in development, neuroprotection, metabolism, and plasticity in the brain. These diverse cellular and physiological IR activities are distinct from metabolic IR functions in peripheral tissues, thus highlighting region specificity of IR properties. This particularly concerns the fact that two IR isoforms, A and B, are predominantly expressed in either the brain or peripheral tissues, respectively, and neurons express exclusively IR-A. Intriguingly, in comparison with IR-B, IR-A displays high binding affinity and is also activated by low concentrations of insulin-like growth factor-2 (IGF-2), a regulator of neuronal plasticity, whose dysregulation is associated with neuropathologic processes. Deficiencies in IR activation, insulin availability, and downstream IR-related mechanisms may result in aberrant IR-mediated functions and, subsequently, a broad range of brain disorders, including neurodevelopmental syndromes, neoplasms, neurodegenerative conditions, and depression. Here, we discuss findings on the brain-specific features of IR-mediated signaling with focus on mechanisms of primary receptor activation and their roles in the neuropathology. We aimed to uncover the remaining gaps in current knowledge on IR physiology and highlight new therapies targeting IR, such as IR sensitizers. © 2018 John Wiley & Sons Ltd.
Results from the Air Force Geophysics Laboratory survey catalog. [IR astronomy
NASA Technical Reports Server (NTRS)
Price, S. D.; Walker, R. G.
1977-01-01
Results of an IR survey program designed to obtain the spatial and brightness distributions of a representative sample of IR-emitting objects in the 3-30 micron range are analyzed. Small cryogenically cooled telescopes carried above the atmosphere on sounding rockets were employed in the research. Minimization of sky noise and photon background, experimental equipment, and data reduction techniques are discussed.
Emission characteristics of dispenser cathodes with a fine-grained tungsten top layer
NASA Astrophysics Data System (ADS)
Kimura, S.; Higuchi, T.; Ouchi, Y.; Uda, E.; Nakamura, O.; Sudo, T.; Koyama, K.
1997-02-01
In order to improve the emission stability of the Ir-coated dispenser cathode under ion bombardment, a fine-grained tungsten top layer was applied on the substrate porous tungsten plug before Ir coating. The emission characteristics were studied after being assembled in a CRT gun. Cathode current was measured under pulse operation in a range of 0.1-9% duty. Remarkable anti-ion bombardment characteristics were observed over the range of 1-6% duty. The improved cathode showed 1.5 times higher emission current than that of a conventional Ir-coated dispenser cathode at 4% duty. AES analysis showed that the recovering rates of surface Ba and O atoms after ion bombardment were 2.5 times higher. From these results it is confirmed that the Ir coated cathode with a fine-grained tungsten top layer is provided with a good tolerance against the ion bombardment.
Reference ranges of HOMA-IR in normal-weight and obese young Caucasians.
Shashaj, Blegina; Luciano, Rosa; Contoli, Benedetta; Morino, Giuseppe Stefano; Spreghini, Maria Rita; Rustico, Carmela; Sforza, Rita Wietrzycowska; Dallapiccola, Bruno; Manco, Melania
2016-04-01
Insulin resistance (IR) may develop very early in life being associated with occurrence of cardiometabolic risk factors (CMRFs). Aim of the present study was to identify in young Caucasians normative values of IR as estimated by the homeostasis model assessment (HOMA-IR) and cutoffs diagnostic of CMRFs. Anthropometrics and biochemical parameters were assessed in 2753 Caucasians (age 2-17.8 years; 1204 F). Reference ranges of HOMA-IR were defined for the whole population and for samples of normal-weight and overweight/obese individuals. The receiver operator characteristic analysis was used to find cutoffs of HOMA-IR accurately identifying individuals with any CMRF among total cholesterol and/or triglycerides higher than the 95th percentile and/or HDL cholesterol lower than the 5th for age and sex, impaired glucose tolerance, and alanine aminotransferase levels ≥40 U/l. Overweight/obese individuals had higher HOMA-IR levels compared with normal-weight peers (p < 0.0001) at any age. HOMA-IR index rose progressively with age, plateaued between age 13 and 15 years and started decreasing afterward. HOMA-IR peaked at age 13 years in girls and at 15 years in boys. The 75th percentile of HOMA-IR in the whole population (3.02; AUROC = 0.73, 95 % CI = 0.70-0.75), in normal-weight (1.68; AUROC = 0.76, 95 % CI = 0.74-0.79), and obese (3.42; AUROC = 0.71, 95 % CI = 0.69-0.72) individuals identified the cutoffs best classifying individuals with any CMRF. Percentiles of HOMA-IR varied significantly in young Caucasians depending on sex, age, and BMI category. The 75th percentile may represent an accurate cutoff point to suspect the occurrence of one or more CMRFs among high total cholesterol and triglycerides, low HDL cholesterol, and ALT ≥ 40 UI/l.
Attosecond control of dissociative ionization of O{sub 2} molecules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siu, W.; Kelkensberg, F.; Gademann, G.
We demonstrate that dissociative ionization of O{sub 2} can be controlled by the relative delay between an attosecond pulse train (APT) and a copropagating infrared (IR) field. Our experiments reveal a dependence of both the branching ratios between a range of electronic states and the fragment angular distributions on the extreme ultraviolet (XUV) to IR time delay. The observations go beyond adiabatic propagation of dissociative wave packets on IR-induced quasistatic potential energy curves and are understood in terms of an IR-induced coupling between electronic states in the molecular ion.
Coatings masking in near, medium, and far infrared used for ship camouflage
NASA Astrophysics Data System (ADS)
Milewski, S.; Dulski, R.; Kastek, M.; Trzaskawka, P.; Barela, J.; Firmanty, K.
2011-11-01
The increasing range of naval engagements results in development of camouflages applied on warships that mask their signatures first in visible and next in and IR spectra. Camouflage applied on warships that mask their IR signatures is one of the most basic countermeasure methods against attacks by heat-seeking missiles. A set of special coatings applied to the ship's hull allows misidentification by enemies weapon and so make the ship harder to destroy. Thus the knowledge on actual thermal contrast between the ship and surrounding background is required in order to provide an effective antimissile defense. The paper presents selected aspects related to ship's camouflage realized by altering its thermal signature as well as the results of radiometric measurement of thermal radiation of IR-masking coatings. Measurements were performed using IR imaging spectrometers in near, medium and far infrared spectra. The presented measurement results constitute the basis for the assessment of the effectiveness of IR masking methods and additionally provide the opportunity to effectively simulate the properties of masking coatings and further to optimize their radiometric properties in the infrared range.
NASA Astrophysics Data System (ADS)
Liu, Yan; Yu, Li; Jia, Xiaowen; Zhao, Jianzhou; Weng, Hongming; Peng, Yingying; Chen, Chaoyu; Xie, Zhuojin; Mou, Daixiang; He, Junfeng; Liu, Xu; Feng, Ya; Yi, Hemian; Zhao, Lin; Liu, Guodong; He, Shaolong; Dong, Xiaoli; Zhang, Jun; Xu, Zuyan; Chen, Chuangtian; Cao, Gang; Dai, Xi; Fang, Zhong; Zhou, X. J.
2015-08-01
The low energy electronic structure of Sr2IrO4 has been well studied and understood in terms of an effective Jeff = 1/2 Mott insulator model. However, little work has been done in studying its high energy electronic behaviors. Here we report a new observation of the anomalous high energy electronic structure in Sr2IrO4. By taking high-resolution angle-resolved photoemission measurements on Sr2IrO4 over a wide energy range, we have revealed for the first time that the high energy electronic structures show unusual nearly-vertical bands that extend over a large energy range. Such anomalous high energy behaviors resemble the high energy waterfall features observed in the cuprate superconductors. While strong electron correlation plays an important role in producing high energy waterfall features in the cuprate superconductors, the revelation of the high energy anomalies in Sr2IrO4, which exhibits strong spin-orbit coupling and a moderate electron correlation, points to an unknown and novel route in generating exotic electronic excitations.
Liu, Yan; Yu, Li; Jia, Xiaowen; Zhao, Jianzhou; Weng, Hongming; Peng, Yingying; Chen, Chaoyu; Xie, Zhuojin; Mou, Daixiang; He, Junfeng; Liu, Xu; Feng, Ya; Yi, Hemian; Zhao, Lin; Liu, Guodong; He, Shaolong; Dong, Xiaoli; Zhang, Jun; Xu, Zuyan; Chen, Chuangtian; Cao, Gang; Dai, Xi; Fang, Zhong; Zhou, X J
2015-08-12
The low energy electronic structure of Sr2IrO4 has been well studied and understood in terms of an effective Jeff = 1/2 Mott insulator model. However, little work has been done in studying its high energy electronic behaviors. Here we report a new observation of the anomalous high energy electronic structure in Sr2IrO4. By taking high-resolution angle-resolved photoemission measurements on Sr2IrO4 over a wide energy range, we have revealed for the first time that the high energy electronic structures show unusual nearly-vertical bands that extend over a large energy range. Such anomalous high energy behaviors resemble the high energy waterfall features observed in the cuprate superconductors. While strong electron correlation plays an important role in producing high energy waterfall features in the cuprate superconductors, the revelation of the high energy anomalies in Sr2IrO4, which exhibits strong spin-orbit coupling and a moderate electron correlation, points to an unknown and novel route in generating exotic electronic excitations.
The magnetic and crystal structures of Sr2IrO4: A neutron diffraction study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, Feng; Chi, Songxue; Chakoumakos, Bryan C
2013-01-01
We report a single-crystal neutron diffraction study of the layered Sr2IrO4. This work unambigu- ously determines the magnetic and crystal structures, and reveals that the spin orientation rigidly tracks the staggered rotation of the IrO6 octahedra in Sr2IrO4. The long-range antiferromagnetic order has a canted spin configuration with an ordered moment of 0.208(3) B/Ir site within the basal plane; a detailed examination of the spin canting yields 0.202(3) and 0.049(2) B/site for the a-axis and the b-axis, respectively. It is intriguing that forbidden nuclear reflections of space group I41/acd are also observed in a wide temperature range from 4 Kmore » to 600 K, which suggests a reduced crystal structure symmetry. This neutron scattering work provides a direct, well-refined experimen- tal characterization of the magnetic and crystal structures that are crucial to the understanding of the unconventional magnetism existent in this unusual magnetic insulator.« less
Unaka, Ndidi I; Statile, Angela; Haney, Julianne; Beck, Andrew F; Brady, Patrick W; Jerardi, Karen E
2017-02-01
The average American adult reads at an 8th-grade level. Discharge instructions written above this level might increase the risk of adverse outcomes for children as they transition from hospital to home. We conducted a cross-sectional study at a large urban academic children's hospital to describe readability levels, understandability scores, and completeness of written instructions given to families at hospital discharge. Two hundred charts for patients discharged from the hospital medicine service were randomly selected for review. Written discharge instructions were extracted and scored for readability (Fry Readability Scale [FRS]), understandability (Patient Education Materials Assessment Tool [PEMAT]), and completeness (5 criteria determined by consensus). Descriptive statistics enumerated the distribution of readability, understandability, and completeness of written discharge instructions. Of the patients included in the study, 51% were publicly insured. Median age was 3.1 years, and median length of stay was 2.0 days. The median readability score corresponded to a 10th-grade reading level (interquartile range, 8-12; range, 1-13). Median PEMAT score was 73% (interquartile range, 64%-82%; range, 45%-100%); 36% of instructions scored below 70%, correlating with suboptimal understandability. The diagnosis was described in only 33% of the instructions. Although explicit warning signs were listed in most instructions, 38% of the instructions did not include information on the person to contact if warning signs developed. Overall, the readability, understandability, and completeness of discharge instructions were subpar. Efforts to improve the content of discharge instructions may promote safe and effective transitions home. Journal of Hospital Medicine 2017;12:98-101. © 2017 Society of Hospital Medicine.
Electromagnetic Navigation Bronchoscopy for Identifying Lung Nodules for Thoracoscopic Resection.
Marino, Katy A; Sullivan, Jennifer L; Weksler, Benny
2016-08-01
Pulmonary nodules smaller than 1 cm can be difficult to identify during minimally invasive resection, necessitating conversion to thoracotomy. We hypothesized that localizing nodules with electromagnetic navigation bronchoscopy and marking them with methylene blue would allow minimally invasive resection and reduce conversion to thoracotomy. We retrospectively identified all patients who underwent electromagnetic navigation bronchoscopy followed by minimally invasive resection of a pulmonary nodule from 2011 to 2014. Lung nodules smaller than 10 mm and nodules smaller than 20 mm that were also located more than 10 mm from the pleural surface were localized and marked with methylene blue. Immediately after marking, all patients underwent resection. Seventy patients underwent electromagnetic navigation bronchoscopy marking followed by minimally invasive resection. The majority of patients (68/70, 97%) had one nodule localized; 2 patients (2/70, 3%) had two nodules localized. The median nodule size was 8 mm (range, 4-17 mm; interquartile range, 5 mm). The median distance from the pleural surface was 6 mm (range, 1-19 mm; interquartile range, 6 mm). There were no conversions to thoracotomy. Nodule marking was successful in 70 of 72 attempts (97.2%); two nodules were identified by palpation. The nodules were most commonly metastases from other sites (31/70, 44.3%). There were no adverse events related to electromagnetic navigation bronchoscopy-guided marking or wedge resection, and minimal adverse events after resections that were more extensive. Localizing and marking small pulmonary nodules using electromagnetic navigation bronchoscopy is safe and effective for nodule identification before minimally invasive resection. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Nowak, Rebecca G; Gravitt, Patti E; He, Xin; Ketende, Sosthenes; Dauda, Wuese; Omuh, Helen; Blattner, William A; Charurat, Manhattan E
2016-04-01
Prevalence estimates of anal high-risk human papillomavirus (HR-HPV) are needed in sub-Saharan Africa where HIV is endemic. This study evaluated anal HR-HPV in Nigeria among HIV-positive and HIV-negative men who have sex with men (MSM) for future immunization recommendations. We conducted a cross-sectional study to compare the prevalence of anal HR-HPV infections between 64 HIV-negative and 90 HIV-positive MSM. Multivariate Poisson regression analyses were used to examine demographic and behavioral risk factors associated with any HR-HPV infections. The median age of the 154 participants was 25 years (interquartile range, 22-28 years; range, 16-38 years), and the median age at initiation of anal sex with another man was 16 years (interquartile range, 13-18 years; range, 7-29 years). The prevalence of anal HR-HPV was higher among HIV-positive than HIV-negative MSM (91.1% vs. 40.6%, P < 0.001). In the multivariate analysis, HIV infection (adjusted prevalence ratio [aPR], 2.02; 95% confidence interval [CI], 1.49-2.72), 10 years or more since anal sexual debut (aPR, 1.26; 95% CI, 1.07-1.49), and concurrent relationships with men (aPR, 1.32; 95% CI, 1.04-1.67) were associated with increased anal HR-HPV prevalence. Anal HR-HPV infection is high for young Nigerian MSM, and rates are amplified in those coinfected with HIV. Providing universal coverage as well as catch-up immunization for young MSM may be an effective anal cancer prevention strategy in Nigeria.
Hecht, Silke; Adams, W H; Cunningham, M A; Lane, I F; Howell, N E
2013-01-01
Effective teaching of veterinary radiology can be challenging in a traditional classroom environment. Audience response systems, colloquially known as "clickers," provide a means of encouraging student interaction. The purpose of this study was to compare student performance and course evaluations before and after using the Classroom Performance System™ in the third-year (fifth semester) didactic radiology course at the University of Tennessee College of Veterinary Medicine. Overall student performance was assessed by comparing median numeric final course grades (%) between years without and with use of the Classroom Performance System™. Grades of students were determined for individual instructors' sections. Student evaluations of the radiology course were compared for the years available (2007-2010). Student interactions were also evaluated subjectively by instructors who used the Classroom Performance System™. There was a significant difference (p = 0.009) between the median student grade before (2005 - 2008, median 82.2%; interquartile range 77.6-85.7%; range 61.9-95.5%) and after use of the classroom performance system (2009-2010, median 83.6%; interquartile range 79.9-87.9%; range 68.2-93.2%). There was no statistically significant difference in median student grades for individual instructors over the study period. The radiology course student evaluation scores were significantly higher in years where the Classroom Performance System™ was used in comparison to previous years (P = 0.019). Subjectively, students appeared more involved when using clickers. Findings indicated that the Classroom Performance System™ may be a useful tool for enhancing veterinary radiology education. © 2012 Veterinary Radiology & Ultrasound.
O'Connor, Jeremy M; Fessele, Kristen L; Steiner, Jean; Seidl-Rathkopf, Kathi; Carson, Kenneth R; Nussbaum, Nathan C; Yin, Emily S; Adelson, Kerin B; Presley, Carolyn J; Chiang, Anne C; Ross, Joseph S; Abernethy, Amy P; Gross, Cary P
2018-05-10
The US Food and Drug Administration (FDA) is increasing its pace of approvals for novel cancer therapeutics, including for immune checkpoint inhibitors of programmed cell death 1 protein (anti-PD-1 agents). However, little is known about how quickly anti-PD-1 agents reach eligible patients in practice or whether such patients differ from those studied in clinical trials that lead to FDA approval (pivotal clinical trials). To assess the speed with which anti-PD-1 agents reached eligible patients in practice and to compare the ages of patients treated in clinical practice with the ages of those treated in pivotal clinical trials. This retrospective cohort study, performed from January 1, 2011, through August 31, 2016, included patients from the Flatiron Health Network who were eligible for anti-PD-1 treatment of selected cancer types, which included melanoma, non-small cell lung cancer (NSCLC), and renal cell carcinoma (RCC). Cumulative proportions of eligible patients receiving anti-PD-1 treatment and their age distributions. The study identified 3089 patients who were eligible for anti-PD-1 treatment (median age, 66 [interquartile range, 56-75] years for patients with melanoma, 66 [interquartile range, 58-72] years for patients with RCC, and 67 [interquartile range, 59-74] years for patients with NSCLC; 1742 male [56.4%] and 1347 [43.6%] female; 2066 [66.9%] white). Of these patients, 2123 (68.7%) received anti-PD-1 treatment, including 439 eligible patients with melanoma (79.1%), 1417 eligible patients with NSCLC (65.6%), and 267 eligible patients with RCC (71.2%). Within 4 months after FDA approval, greater than 60% of eligible patients in each cohort had received anti-PD-1 treatment. Overall, similar proportions of older and younger patients received anti-PD-1 treatment during the first 9 months after FDA approval. However, there were significant differences in age between clinical trial participants and patients receiving anti-PD-1 treatment in clinical practice, with more patients being older than 65 years in clinical practice (range, 327 of 1365 [60.6%] to 46 of 72 [63.9%]) than in pivotal clinical trials (range, 38 of 120 [31.7%] to 223 of 544 [41.0%]; all P < .001). Anti-PD-1 agents rapidly reached patients in clinical practice, and patients treated in clinical practice differed significantly from patients treated in pivotal clinical trials. Future actions are needed to ensure that rapid adoption occurs on the basis of representative trial evidence.
Bongiovanni, Marzia; Fresa, Raffaella; Visalli, Natalia; Bitterman, Olimpia; Suraci, Concetta; Napoli, Angela
2016-06-01
The aim of this study was to assess carbohydrate (CHO)-to-insulin ratio (CHO/IR) values in pregnant women with type 1 diabetes and to describe differences in CHO/IR across each week of pregnancy. This was a multicenter, retrospective, observational study (2006-2012) of 101 white pregnant women with a mean age of 32 (range, 18-43) years who had type 1 diabetes and were under continuous subcutaneous insulin infusion (CSII) therapy. These patients had the following characteristics: type 1 diabetes duration was 1 year (range, 1-31 years), the pregestational glycosylated hemoglobin level was 6.9% (range, 6.8-12.1%), the median weight gain during pregnancy was 14 kg (-3; 25 kg), with delivery at 37 weeks (range, 30-40 weeks), and the child had a birth weight of 3.530 kg (range, 1.480-5.250 kg). The CHO/IR was measured by dividing the CHO (in g) of each meal by insulin unit injected to acquire and maintain the following glycemic targets: fasting <90 mg/dL and 1-h postprandial <130 mg/dL. Simultaneously, CHO/IR indices were calculated through 500/total daily doses of insulin and 300/total daily doses of insulin. Education and management before and during pregnancy were in agreement with Italian Association of Dietitians, Association of Medical Diabetologists, and Italian Society of Diabetology recommendations. Data were analyzed using SPSS software (version 20.0; SPSS, Inc., Chicago, IL). The CHO/IR decreased on average from 9.6 (5-18) to 5.4 (2.3-8) at breakfast, from 10 (3.5-16) to 8.4 (3.0-17.8) at lunch, and from 12.5 (8-20) to 6.1 (4.2-12) at dinner. The CHO/IR calculated using the "500 rule" decreased from 14.3 (10-20.3) to 8.6 (4.1-15.9). Using the "300 rule," the ratios decreased from 8.5 (6-12.1) to 5.2 (2.4-9.5). The bivariate correlation between the values calculated more appropriate values using the "300 rule" for breakfast and the "500 rule" for lunch and dinner across all weeks of pregnancy. CHO/IR reduction in pregnancy is likely due to an increase in insulin resistance.
Single ZnO nanowire-PZT optothermal field effect transistors.
Hsieh, Chun-Yi; Lu, Meng-Lin; Chen, Ju-Ying; Chen, Yung-Ting; Chen, Yang-Fang; Shih, Wan Y; Shih, Wei-Heng
2012-09-07
A new type of pyroelectric field effect transistor based on a composite consisting of single zinc oxide nanowire and lead zirconate titanate (ZnO NW-PZT) has been developed. Under infrared (IR) laser illumination, the transconductance of the ZnO NW can be modulated by optothermal gating. The drain current can be increased or decreased by IR illumination depending on the polarization orientation of the Pb(Zr(0.3)Ti(0.7))O(3) (PZT) substrate. Furthermore, by combining the photocurrent behavior in the UV range and the optothermal gating effect in the IR range, the wide spectrum of response of current by light offers a variety of opportunities for nanoscale optoelectronic devices.
Glass formation and short-range order structures in the BaS + La 2S 3 + GeS 2 system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Josh R.; Martin, Steve W.; Ballato, John
Here, infrared (IR) optical materials have enabled a broad range of optical sensing and measurement applications in the mid-wave and long-wave IR. Many IR transmitting glasses are based on covalently-bonded selenides and tellurides, such as As 2Se 3 and GeTe 2, which typically have relatively low glass transition temperatures ( T g) on the order of 200 to 350 °C. Many applications have working temperatures above the T g of these materials, which compels the development of new IR materials. This work studies the underlying short-range order (SRO) structure and glass formability of a new family of ionically-bonded sulfide glasses,more » xBaS + yLa 2S 3 + (1 – x – y)GeS 2, to develop high T g optical materials with a broad IR transmission range. These sulfide glasses were produced by melting sulfide materials inside evacuated and sealed carbon-coated silica ampoules at 1150 °C for 12 h and quenching to room temperature to form glass. Glass samples were then characterized by IR and Raman spectroscopies and differential thermal analysis (DTA). It was found that by increasing the modifier concentration, the predominantly Ge 4 SRO units, the superscript defines the number of bridging sulfur (BS) ions in the tetrahedral network found in GeS 2 glasses, are ultimately converted to Ge 0 units at >40 mol% network modifier content through the generation of non-bridging sulfur (NBS) ions. These molecular ionic units still form a glassy network, with some of the highest reported T g values to date for a pure sulfide glass. This suggests that this composition has strong ionic bonds between negatively-charged tetrahedral SRO units and the positively-charged modifier cations. While the glass network is depolymerized in the high modifier content glasses though the formation of a high concentration of molecular ionic Ge 0 SRO groups, they are, nevertheless, homogeneous glassy materials that exhibit the largest T g and Δ T (difference between crystallization temperature, T c, and T g) values of glasses in this system, making them the optimal glasses for high T g IR optical components, including, potentially, refractory IR optical fibers.« less
Glass formation and short-range order structures in the BaS + La 2S 3 + GeS 2 system
Roth, Josh R.; Martin, Steve W.; Ballato, John; ...
2018-06-01
Here, infrared (IR) optical materials have enabled a broad range of optical sensing and measurement applications in the mid-wave and long-wave IR. Many IR transmitting glasses are based on covalently-bonded selenides and tellurides, such as As 2Se 3 and GeTe 2, which typically have relatively low glass transition temperatures ( T g) on the order of 200 to 350 °C. Many applications have working temperatures above the T g of these materials, which compels the development of new IR materials. This work studies the underlying short-range order (SRO) structure and glass formability of a new family of ionically-bonded sulfide glasses,more » xBaS + yLa 2S 3 + (1 – x – y)GeS 2, to develop high T g optical materials with a broad IR transmission range. These sulfide glasses were produced by melting sulfide materials inside evacuated and sealed carbon-coated silica ampoules at 1150 °C for 12 h and quenching to room temperature to form glass. Glass samples were then characterized by IR and Raman spectroscopies and differential thermal analysis (DTA). It was found that by increasing the modifier concentration, the predominantly Ge 4 SRO units, the superscript defines the number of bridging sulfur (BS) ions in the tetrahedral network found in GeS 2 glasses, are ultimately converted to Ge 0 units at >40 mol% network modifier content through the generation of non-bridging sulfur (NBS) ions. These molecular ionic units still form a glassy network, with some of the highest reported T g values to date for a pure sulfide glass. This suggests that this composition has strong ionic bonds between negatively-charged tetrahedral SRO units and the positively-charged modifier cations. While the glass network is depolymerized in the high modifier content glasses though the formation of a high concentration of molecular ionic Ge 0 SRO groups, they are, nevertheless, homogeneous glassy materials that exhibit the largest T g and Δ T (difference between crystallization temperature, T c, and T g) values of glasses in this system, making them the optimal glasses for high T g IR optical components, including, potentially, refractory IR optical fibers.« less
Fabrication of flexible Ir and Ir-Rh wires and application for thermocouple
NASA Astrophysics Data System (ADS)
Murakami, Rikito; Kamada, Kei; Shoji, Yasuhiro; Yokota, Yuui; Yoshino, Masao; Kurosawa, Shunsuke; Ohashi, Yuji; Yamaji, Akihiro; Yoshikawa, Akira
2018-04-01
The fabrication and thermal electromotive force characteristics of Ir/Ir-Rh thermocouples capable of repeated bending deformation are described. Ir and Ir-Rh wires with a diameter of 0.5 mm were fabricated using the alloy-micro-pulling-down method. Scanning electron microscopy and electron backscattering diffraction of the radial cross section of the grown wires were performed to investigate the microstructure and orientation of the crystal grains. At the start of growth, the microstructure was polycrystalline with diameters of several hundred micrometers, while at the 8-m growth point it was found to be monocrystalline. The observed single crystals of pure Ir and Ir-Rh alloy were oriented in the 〈1 1 3〉 and 〈1 1 2〉 directions, respectively, whereas the polycrystalline Ir-Rh samples showed preferential growth in the 〈1 0 0〉 direction. The thermal electromotive force of the fabricated Ir/Ir-Rh thermocouple was measured by the comparison technique and the fixed-point technique, and the thermoelectric power was estimated to be 5.9 μV/°C in the range from 600°C to 1100°C.
Structure symmetry determination and magnetic evolution in Sr 2Ir 1–xRh xO 4
Ye, Feng; Wang, Xiaoping; Hoffmann, Christina; ...
2015-11-23
We use single-crystal neutron diffraction to determine the crystal structure symmetry and to study the magnetic evolution in the rhodium doped iridates Sr 2Ir 1–xRh xO 4 (0 ≤ x ≤ 0.16). Throughout this doping range, the crystal structure retains a tetragonal symmetry (space group I4 1/a) with two distinct magnetic Ir sites in the unit cell forming staggered IrO 6 rotation. Upon Rh doping, the magnetic order is suppressed and the magnetic moment of Ir4+ is reduced from 0.21 μ B/Ir for x = 0 to 0.18 μ B/Ir for x = 0.12. As a result, the magnetic structuremore » at x = 0.12 is different from that of the parent compound while the moments remain in the basal plane.« less
Hou, Dianwei; Nissimagoudar, Arun S; Bian, Qiang; Wu, Kui; Pan, Shilie; Li, Wu; Yang, Zhihua
2018-06-15
Infrared nonlinear optical (IR NLO) crystals are the major materials to widen the output range of solid-state lasers to mid- or far-infrared regions. The IR NLO crystals used in the middle IR region are still inadequate for high-power laser applications because of deleterious thermal effects (lensing and expansion), low laser-induced damage threshold, and two-photon absorption. Herein, the unbiased global minimum search method was used for the first time to search for IR NLO optical materials and ultimately found a new IR NLO material NaGaS 2 . It meets the stringent demands for IR NLO materials pumped by high-power laser with the highest thermal conductivity among common IR NLO materials able to avoid two-photon absorption, a classic nonlinear coefficient, and wide infrared transparency.
NASA Astrophysics Data System (ADS)
Spinoglio, L.; Alonso-Herrero, A.; Armus, L.; Baes, M.; Bernard-Salas, J.; Bianchi, S.; Bocchio, M.; Bolatto, A.; Bradford, C.; Braine, J.; Carrera, F. J.; Ciesla, L.; Clements, D. L.; Dannerbauer, H.; Doi, Y.; Efstathiou, A.; Egami, E.; Fernández-Ontiveros, J. A.; Ferrara, A.; Fischer, J.; Franceschini, A.; Gallerani, S.; Giard, M.; González-Alfonso, E.; Gruppioni, C.; Guillard, P.; Hatziminaoglou, E.; Imanishi, M.; Ishihara, D.; Isobe, N.; Kaneda, H.; Kawada, M.; Kohno, K.; Kwon, J.; Madden, S.; Malkan, M. A.; Marassi, S.; Matsuhara, H.; Matsuura, M.; Miniutti, G.; Nagamine, K.; Nagao, T.; Najarro, F.; Nakagawa, T.; Onaka, T.; Oyabu, S.; Pallottini, A.; Piro, L.; Pozzi, F.; Rodighiero, G.; Roelfsema, P.; Sakon, I.; Santini, P.; Schaerer, D.; Schneider, R.; Scott, D.; Serjeant, S.; Shibai, H.; Smith, J.-D. T.; Sobacchi, E.; Sturm, E.; Suzuki, T.; Vallini, L.; van der Tak, F.; Vignali, C.; Yamada, T.; Wada, T.; Wang, L.
2017-11-01
IR spectroscopy in the range 12-230 μm with the SPace IR telescope for Cosmology and Astrophysics (SPICA) will reveal the physical processes governing the formation and evolution of galaxies and black holes through cosmic time, bridging the gap between the James Webb Space Telescope and the upcoming Extremely Large Telescopes at shorter wavelengths and the Atacama Large Millimeter Array at longer wavelengths. The SPICA, with its 2.5-m telescope actively cooled to below 8 K, will obtain the first spectroscopic determination, in the mid-IR rest-frame, of both the star-formation rate and black hole accretion rate histories of galaxies, reaching lookback times of 12 Gyr, for large statistically significant samples. Densities, temperatures, radiation fields, and gas-phase metallicities will be measured in dust-obscured galaxies and active galactic nuclei, sampling a large range in mass and luminosity, from faint local dwarf galaxies to luminous quasars in the distant Universe. Active galactic nuclei and starburst feedback and feeding mechanisms in distant galaxies will be uncovered through detailed measurements of molecular and atomic line profiles. The SPICA's large-area deep spectrophotometric surveys will provide mid-IR spectra and continuum fluxes for unbiased samples of tens of thousands of galaxies, out to redshifts of z 6.
Infrared measurements on ultraviolet photolysis products at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Dong, Weibing; He, Ping; Wang, Jessie; Zhou, Zhaohui; Wang, Hongxin
2013-01-01
Combination of ultraviolet (UV) photolysis with infrared (IR) spectroscopy (or UV/IR for abbreviation) is a powerful tool to study various chemical photoreactions, while cryostat and sample-cell windows define the working ranges for both UV and IR beams. Although diamond window has a very wide transmission range from UV to IR, the extreme cost, the absorptions at 1800-2600 cm-1 and other problems prevent it from being the solution for all cases. In this paper, a gas-exchange cryostat was modified to realize a UV/mid-IR experiment at cryogenic temperatures. Several windows (including diamond) were discussed as options. A di-nitrogen iron complex trans-[Fe(DMeOPrPE)2(N2)H][BPh4] [DMeOPrPE = 1,2-bis(dimethoxypropylphosphino)ethane] was studied as a real photolysis example. Alternatively, a cold-finger cryostat was modified for UV/far-IR compatible experiments. Non-photolysis samples K5[Mo4O11(R,S-Hhomocit)2]Cl·5H2O (H4homocit = homocitric acid) and [(n-Bu)4N]2[Fe4S4(PPh)4] were studied at cryogenic temperatures. Sample cell windows can also be used as a natural way for choosing photolysis wavelength (in addition to the use of optical filters).
Dilute stuffing in the pyrochlore iridate Eu2Ir2O7
NASA Astrophysics Data System (ADS)
Telang, Prachi; Mishra, Kshiti; Sood, A. K.; Singh, Surjeet
2018-06-01
The pyrochlore Eu2Ir2O7 has recently attracted significant attention as a candidate Weyl semimetal. The previous reports on this compound unanimously show a thermally induced metal-to-insulator (MI) transition, concomitant with antiferromagnetic long-range ordering of the Ir moments below TN˜120 K. However, there are contradictory reports concerning the slope d ρ /d T of the resistivity plots (ρ ) in the "metallic" state above the MI transition, and the value of ρ in the insulating state, both of which show significant sample dependence. Here, we explore this issue by investigating six different Eu2Ir2O7 samples with slightly varying Eu:Ir ratio. High-resolution synchrotron powder diffraction is done to probe minor variations in the cell parameters of the various Eu2Ir2O7 samples investigated here. Specific heat (Cp) and magnetic susceptibility of all the samples showed long-range antiferromagnetic ordering upon cooling below TN˜120 K. The transitions are, however, found to be smeared out for the off-stoichiometric samples. We show that the sign of d ρ /d T above the MI transition is highly sensitive to the unit-cell length, which, in turn, depends on the level of Eu stuffing at the Ir site. Samples with composition close to the ideal stoichiometry (Eu:Ir =1 ) showed a change of sign of d ρ /d T from negative to positive upon cooling below a certain temperature T*>TMI . With increasing Eu stuffing, T* decreased until a negative d ρ /d T persisted without any sign change down to TMI.
Linder, Brian J; Rivera, Marcelino E; Ziegelmann, Matthew J; Elliott, Daniel S
2015-09-01
To evaluate long-term device outcomes following primary artificial urinary sphincter (AUS) implantation. We identified 1802 male patients with stress urinary incontinence that underwent AUS placement from 1983 to 2011. Of these, 1082 (60%) were involving primary implantations and comprise the study cohort. Multiple clinical and surgical variables were evaluated for potential association with treatment failure, defined as any secondary surgery. Patient follow-up was obtained through office examination, operative report, and written or telephone correspondence. Patients undergoing AUS implantation had a median age of 71 years (interquartile range 66-76) and median follow-up of 4.1 years (interquartile range 0.8-7.7). Overall, 338 of 1082 patients (31.2%) underwent secondary surgery, including 89 for device infection and/or erosion, 131 for device malfunction, 89 for urethral atrophy, and 29 for pump malposition or tubing complications. No patient-related risk factors were independently associated with an increased risk of secondary surgery on multivariable analysis. Secondary surgery-free survival was 90% at 1 year, 74% at 5 years, 57% at 10 years, and 41% at 15 years. Primary AUS implantation is associated with acceptable long-term outcomes. Recognition of long-term success is important for preoperative patient counseling. Copyright © 2015 Elsevier Inc. All rights reserved.
Poola, Ashwini Suresh; Rentea, Rebecca M; Weaver, Katrina L; St Peter, Shawn David
2017-05-01
While there is literature on techniques for pectus bar removal, there are limited reports on post-operative management. This can include obtaining a postoperative chest radiograph (CXR) despite the minimal risk of associated intra-thoracic complications. This is a review of our experience with bar removal and lack of routine post-operative CXR. A single institution retrospective chart review was performed from 2000 to 2015. Patients who underwent a pectus bar removal procedure were included. We assessed operative timing of bar placement and removal, procedure length, intra-operative and post-operative complications and post-operative CXR findings, specifically the rate of pneumothoraces. 450 patients were identified in this study. Median duration of bar placement prior to removal was 35 months (interquartile range 30 and 36 months). Sixtey-four patients obtained a post-operative CXR. Of these, only one (58%) film revealed a pneumothorax; this was not drained. A CXR was not obtained in 386 (86%) patients with no immediate or delayed complications from this practice. Median follow-up time for all patients was 11 months (interquartile range 7.5-17 months). The risk for a clinically relevant pneumothorax is minimal following bar removal. This suggests that not obtaining routine imaging following bar removal may be a safe practice.
van der Westhuizen, J; Kuo, P Y; Reed, P W; Holder, K
2011-03-01
Gastric absorption of oral paracetamol (acetaminophen) may be unreliable perioperatively in the starved and stressed patient. We compared plasma concentrations of parenteral paracetamol given preoperatively and oral paracetamol when given as premedication. Patients scheduled for elective ear; nose and throat surgery or orthopaedic surgery were randomised to receive either oral or intravenous paracetamol as preoperative medication. The oral dose was given 30 minutes before induction of anaesthesia and the intravenous dose given pre-induction. All patients were given a standardised anaesthetic by the same specialist anaesthetist who took blood for paracetamol concentrations 30 minutes after the first dose and then at 30 minute intervals for 240 minutes. Therapeutic concentrations of paracetamol were reached in 96% of patients who had received the drug parenterally, and 67% of patients who had received it orally. Maximum median plasma concentrations were 19 mg.l(-1) (interquartile range 15 to 23 mg.l(-1)) and 13 mg.l(-1) (interquartile range 0 to 18 mg.l(-1)) for the intravenous and oral group respectively. The difference between intravenous and oral groups was less marked after 150 minutes but the intravenous preparation gave higher plasma concentrations throughout the study period. It can be concluded that paracetamol gives more reliable therapeutic plasma concentrations when given intravenously.
The impact of a dedicated research education month for anesthesiology residents.
Freundlich, Robert E; Newman, Jessica W; Tremper, Kevin K; Mhyre, Jill M; Kheterpal, Sachin; Sanford, Theodore J; Tait, Alan R
2015-01-01
An educational intervention was implemented at the University of Michigan starting in 2008, in which anesthesiology interns complete a dedicated month-long didactic rotation in evidence-based medicine (EBM) and research methodology. We sought to assess its utility. Scores on a validated EBM test before and after the rotation were compared and assessed for significance of improvement. A survey was also given to gauge satisfaction with the quality of the rotation and self-reported improvement in understanding of EBM topics. Fourteen consecutive interns completed the research rotation during the study period. One hundred percent completed both the pre- and postrotation test. The mean pretest score was 7.78 ± 2.46 (median = 7.5, 0-15 scale, and interquartile range 7.0-10.0) and the mean posttest score was 10.00 ± 2.35 (median = 9.5, interquartile range 8.0-12.3), which represented a statistically significant increase (P = 0.011, Wilcoxon signed-rank test). All fourteen of the residents "agreed" or "strongly agreed" that they would recommend the course to future interns and that the course increased their ability to critically review the literature. Our findings demonstrate that this can be an effective means of improving understanding of EBM topics and anesthesiology research.
Potential Reporting Bias in Neuroimaging Studies of Sex Differences.
David, Sean P; Naudet, Florian; Laude, Jennifer; Radua, Joaquim; Fusar-Poli, Paolo; Chu, Isabella; Stefanick, Marcia L; Ioannidis, John P A
2018-04-17
Numerous functional magnetic resonance imaging (fMRI) studies have reported sex differences. To empirically evaluate for evidence of excessive significance bias in this literature, we searched for published fMRI studies of human brain to evaluate sex differences, regardless of the topic investigated, in Medline and Scopus over 10 years. We analyzed the prevalence of conclusions in favor of sex differences and the correlation between study sample sizes and number of significant foci identified. In the absence of bias, larger studies (better powered) should identify a larger number of significant foci. Across 179 papers, median sample size was n = 32 (interquartile range 23-47.5). A median of 5 foci related to sex differences were reported (interquartile range, 2-9.5). Few articles (n = 2) had titles focused on no differences or on similarities (n = 3) between sexes. Overall, 158 papers (88%) reached "positive" conclusions in their abstract and presented some foci related to sex differences. There was no statistically significant relationship between sample size and the number of foci (-0.048% increase for every 10 participants, p = 0.63). The extremely high prevalence of "positive" results and the lack of the expected relationship between sample size and the number of discovered foci reflect probable reporting bias and excess significance bias in this literature.
Schmid, Sabrina; Goldberg-Bockhorn, Eva; Schwarz, Silke; Rotter, Nicole; Kassubek, Jan; Del Tredici, Kelly; Pinkhardt, Elmar; Otto, Markus; Ludolph, Albert C; Oeckl, Patrick
2018-06-01
In autopsy cases staged for sporadic Parkinson's disease (PD), the neuropathology is characterized by a preclinical phase that targets the enteric nervous system of the gastrointestinal tract (GIT). Therefore, the ENS might be a source of potential (presymptomatic) PD biomarkers. In this clinically based study, we examined the alpha-synuclein (αSyn) concentration in an easily accessible protein storage medium of the GIT, dental calculus, in 21/50 patients with PD and 28/50 age- and gender-matched controls using ELISA. αSyn was detectable in dental calculus and the median concentration in the control patients was 8.6 pg/mg calculus (interquartile range 2.6-13.1 pg/mg). αSyn concentrations were significantly influenced by blood contamination and samples with a hemoglobin concentration of > 4000 ng/mL were excluded. There was no significant difference of αSyn concentrations in the dental calculus of PD patients (5.76 pg/mg, interquartile range 2.91-9.74 pg/mg) compared to those in controls (p = 0.40). The total αSyn concentration in dental calculus is not a suitable biomarker for sporadic PD. Disease-related variants such as oligomeric or phosphorylated αSyn in calculus might prove to be more specific.
Central obesity, leptin and cognitive decline: the Sacramento Area Latino Study on Aging.
Zeki Al Hazzouri, Adina; Haan, Mary N; Whitmer, Rachel A; Yaffe, Kristine; Neuhaus, John
2012-01-01
Central obesity is a risk factor for cognitive decline. Leptin is secreted by adipose tissue and has been associated with better cognitive function. Aging Mexican Americans have higher levels of obesity than non-Hispanic Whites, but no investigations examined the relationship between leptin and cognitive decline among them or the role of central obesity in this association. We analyzed 1,480 dementia-free older Mexican Americans who were followed over 10 years. Cognitive function was assessed every 12-15 months with the Modified Mini Mental State Exam (3MSE) and the Spanish and English Verbal Learning Test (SEVLT). For females with a small waist circumference (≤35 inches), an interquartile range difference in leptin was associated with 35% less 3MSE errors and 22% less decline in the SEVLT score over 10 years. For males with a small waist circumference (≤40 inches), an interquartile range difference in leptin was associated with 44% less 3MSE errors and 30% less decline in the SEVLT score over 10 years. There was no association between leptin and cognitive decline among females or males with a large waist circumference. Leptin interacts with central obesity in shaping cognitive decline. Our findings provide valuable information about the effects of metabolic risk factors on cognitive function. Copyright © 2012 S. Karger AG, Basel.
Colacino, Justin A.; Arthur, Anna E.; Ferguson, Kelly K.; Rozek, Laura S.
2014-01-01
Chronic cadmium exposure may cause disease through induction of systemic oxidative stress and inflammation. Factors that mitigate cadmium toxicity and could serve as interventions in exposed populations have not been well characterized. We used data from the 2003–2010 National Health and Nutrition Examination Survey to quantify diet’s role in modifying associations between cadmium exposure and oxidative stress and inflammation. We created a composite antioxidant and anti-inflammatory diet score (ADS) by ranking participants by quintile of intake across a panel of 19 nutrients. We identified associations and effect modification between ADS, urinary cadmium, and markers of oxidative stress and inflammation by multiple linear regression. An interquartile range increase in urinary cadmium was associated with a 47.5%, 8.8%, and 3.7% increase in C-reactive protein (CRP), gamma glutamyl transferase (GGT), and alkaline phosphatase (ALP), respectively. An interquartile range increase in ADS was associated with an 7.4%, 3.3%, 5.2%, and 2.5% decrease in CRP, GGT, ALP, and total white blood cell count respectively, and a 3.0% increase in serum bilirubin. ADS significantly attenuated the association between cadmium exposure, CRP and ALP. Dietary interventions may provide a route to reduce the impact of cadmium toxicity on the population level. PMID:24607659
Vakarin, Vladyslav; Ramírez, Joan Manel; Frigerio, Jacopo; Ballabio, Andrea; Le Roux, Xavier; Liu, Qiankun; Bouville, David; Vivien, Laurent; Isella, Giovanni; Marris-Morini, Delphine
2017-09-01
This Letter explores the use of Ge-rich Si 0.2 Ge 0.8 waveguides on graded Si 1-x Ge x substrate for the demonstration of ultra-wideband photonic integrated circuits in the mid-infrared (mid-IR) wavelength range. We designed, fabricated, and characterized broadband Mach-Zehnder interferometers fully covering a range of 3 μm in the mid-IR band. The fabricated devices operate indistinctly in quasi-TE and quasi-TM polarizations, and have an extinction ratio higher than 10 dB over the entire operating wavelength range. The obtained results are in good correlation with theoretical predictions, while numerical simulations indicate that the device bandwidth can reach one octave with low additional losses. This Letter paves the way for further realization of mid-IR integrated spectrometers using low-index-contrast Si 1-x Ge x waveguides with high germanium concentration.
NASA Astrophysics Data System (ADS)
Martins, Cyril; Lenz, Benjamin; Perfetti, Luca; Brouet, Veronique; Bertran, François; Biermann, Silke
2018-03-01
We address the role of nonlocal Coulomb correlations and short-range magnetic fluctuations in the high-temperature phase of Sr2IrO4 within state-of-the-art spectroscopic and first-principles theoretical methods. Introducing an "oriented-cluster dynamical mean-field scheme", we compute momentum-resolved spectral functions, which we find to be in excellent agreement with angle-resolved photoemission spectra. We show that while short-range antiferromagnetic fluctuations are crucial to accounting for the electronic properties of Sr2IrO4 even in the high-temperature paramagnetic phase, long-range magnetic order is not a necessary ingredient of the insulating state. Upon doping, an exotic metallic state is generated, exhibiting cuprate-like pseudo-gap spectral properties, for which we propose a surprisingly simple theoretical mechanism.
Sensitive photo-thermal response of graphene oxide for mid-infrared detection
NASA Astrophysics Data System (ADS)
Bae, Jung Jun; Yoon, Jung Hyun; Jeong, Sooyeon; Moon, Byoung Hee; Han, Joong Tark; Jeong, Hee Jin; Lee, Geon-Woong; Hwang, Ha Ryong; Lee, Young Hee; Jeong, Seung Yol; Lim, Seong Chu
2015-09-01
This study characterizes the effects of incident infrared (IR) radiation on the electrical conductivity of graphene oxide (GO) and examines its potential for mid-IR detection. Analysis of the mildly reduced GO (m-GO) transport mechanism near room temperature reveals variable range hopping (VRH) for the conduction of electrons. This VRH behavior causes the m-GO resistance to exhibit a strong temperature dependence, with a large negative temperature coefficient of resistance of approximately -2 to -4% K-1. In addition to this hopping transport, the presence of various oxygen-related functional groups within GO enhances the absorption of IR radiation significantly. These two GO material properties are synergically coupled and provoke a remarkable photothermal effect within this material; specifically, a large resistance drop is exhibited by m-GO in response to the increase in temperature caused by the IR absorption. The m-GO bolometer effect identified in this study is different from that exhibited in vanadium oxides, which require added gold-black films that function as IR absorbers owing to their limited IR absorption capability.This study characterizes the effects of incident infrared (IR) radiation on the electrical conductivity of graphene oxide (GO) and examines its potential for mid-IR detection. Analysis of the mildly reduced GO (m-GO) transport mechanism near room temperature reveals variable range hopping (VRH) for the conduction of electrons. This VRH behavior causes the m-GO resistance to exhibit a strong temperature dependence, with a large negative temperature coefficient of resistance of approximately -2 to -4% K-1. In addition to this hopping transport, the presence of various oxygen-related functional groups within GO enhances the absorption of IR radiation significantly. These two GO material properties are synergically coupled and provoke a remarkable photothermal effect within this material; specifically, a large resistance drop is exhibited by m-GO in response to the increase in temperature caused by the IR absorption. The m-GO bolometer effect identified in this study is different from that exhibited in vanadium oxides, which require added gold-black films that function as IR absorbers owing to their limited IR absorption capability. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr04039f
Krishna, Sanjeev; Planche, Tim; Agbenyega, Tsiri; Woodrow, Charles; Agranoff, Dan; Bedu-Addo, George; Owusu-Ofori, Alex K.; Appiah, John Adabie; Ramanathan, Surash; Mansor, Sharif M.; Navaratnam, Visweswaran
2001-01-01
We report the first detailed pharmacokinetic assessment of intrarectal (i.r.) artesunate (ARS) in African children. Artesunate was given intravenously (i.v.; 2.4 mg/kg of body weight) and i.r. (10 or 20 mg/kg formulated as 50- or 200-mg suppositories [Rectocaps]) in a crossover study design to 34 Ghanaian children with moderate falciparum malaria. The median relative bioavailability of dihydroartemisinin (DHA), the active antimalarial metabolite of ARS, was higher in the low-dose i.r. group (10 mg/kg) than in the high-dose i.r. group (20 mg/kg) (58 versus 23%; P = 0.018). There was wide interpatient variation in the area under the concentration-time curve after i.r. ARS administration (up to 9-fold in the high-dose group and 20-fold in the low-dose group). i.r. administered ARS was more rapidly absorbed in the low-dose group than the high-dose group (median [range] absorption half-lives, 0.7 h [0.3 to 1.24 h] versus 1.1 h [0.6 to 2.7 h] [P = 0.023]. i.r. administered ARS was eliminated with a median (range) half-life of 0.8 h (0.4 to 2.7 h) (low-dose group and 0.9 h (0.1 to 2.5 h) (high-dose group) (P = 1). The fractional clearances of DHA were 3.9, 2.6, and 1.5 liters/kg/h for the 20-mg/kg, 10-mg/kg and i.v. groups, respectively (P = 0.001 and P = 0.06 for the high-and low-dose i.r. groups compared with the i.v. groups, respectively). The median volumes of distribution for DHA were 1.5 liters kg (20 mg/kg, i.r. group), 1.8 liters/kg (10 mg/kg, i.r. group), and 0.6 liters/kg (i.v. group) (P < 0.05 for both i.r. groups compared with the i.v. group). Parasite clearance kinetics were comparable in all treatment groups. i.r. administered ARS may be a useful alternative to parenterally administered ARS in the management of moderate childhood malaria and should be studied further. PMID:11158748
Alcaráz, Mirta R; Schwaighofer, Andreas; Goicoechea, Héctor; Lendl, Bernhard
2016-06-01
In this work, a novel EC-QCL-based setup for mid-IR transmission measurements in the amide I region is introduced for monitoring dynamic changes in secondary structure of proteins. For this purpose, α-chymotrypsin (aCT) acts as a model protein, which gradually forms intermolecular β-sheet aggregates after adopting a non-native α-helical structure induced by exposure to 50 % TFE. In order to showcase the versatility of the presented setup, the effects of varying pH values and protein concentration on the rate of β-aggregation were studied. The influence of the pH value on the initial reaction rate was studied in the range of pH 5.8-8.2. Results indicate an increased aggregation rate at elevated pH values. Furthermore, the widely accessible concentration range of the laser-based IR transmission setup was utilized to investigate β-aggregation across a concentration range of 5-60 mg mL(-1). For concentrations lower than 20 mg mL(-1), the aggregation rate appears to be independent of concentration. At higher values, the reaction rate increases linearly with protein concentration. Extended MCR-ALS was employed to obtain pure spectral and concentration profiles of the temporal transition between α-helices and intermolecular β-sheets. Comparison of the global solutions obtained by the modelled data with results acquired by the laser-based IR transmission setup at different conditions shows excellent agreement. This demonstrates the potential and versatility of the EC-QCL-based IR transmission setup to monitor dynamic changes of protein secondary structure in aqueous solution at varying conditions and across a wide concentration range. Graphical abstract EC-QCL IR spectroscopy for monitoring protein conformation change.
Merino-Ingelmo, Raquel; Santos-de Soto, José; Coserria-Sánchez, Félix; Descalzo-Señoran, Alfonso; Valverde-Pérez, Israel
2014-05-01
Percutaneous pulmonary valvuloplasty is the preferred interventional procedure for pulmonary valve stenosis. The aim of this study was to evaluate the effectiveness of this technique, assess the factors leading to its success, and determine the long-term results in the pediatric population. The study included 53 patients with pulmonary valve stenosis undergoing percutaneous balloon valvuloplasty between December 1985 and December 2000. Right ventricular size and functional echocardiographic parameters, such as pulmonary regurgitation and residual transvalvular gradient, were assessed during long-term follow-up. Peak-to-peak transvalvular gradient decreased from 74 mmHg [interquartile range, 65-100 mmHg] to 20 mmHg [interquartile range, 14-34 mmHg]. The procedure was unsuccessful in 2 patients (3.77%). The immediate success rate was 73.58%. Follow-up ranged from 10 years to 24 years (median, 15 years). During follow-up, all patients developed late pulmonary regurgitation which was assessed as grade II in 58.4% and grade III in 31.2%. There was only 1 case of long-term restenosis (2.1%). Severe right ventricular dilatation was observed in 27.1% of the patients. None of the patients developed significant right ventricular dysfunction. Pulmonary valve replacement was not required in any of the patients. Percutaneous balloon valvuloplasty is an effective technique in the treatment of pulmonary valve stenosis with good long-term results. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Impact of Infrared Lunar Laser Ranging on Lunar Dynamics
NASA Astrophysics Data System (ADS)
Viswanathan, Vishnu; Fienga, Agnès; Manche, Hervé; Gastineau, Mickael; Courde, Clément; Torre, Jean-Marie; Exertier, Pierre; Laskar, Jacques; LLR Observers : Astrogeo-OCA, Apache Point, McDonald Laser Ranging Station, Haleakala Observatory, Matera Laser Ranging Observatory
2016-10-01
Since 2015, in addition to the traditional green (532nm), infrared (1064nm) has been the preferred wavelength for lunar laser ranging at the Calern lunar laser ranging (LLR) site in France. Due to the better atmospheric transmission of IR with respect to Green, nearly 3 times the number of normal points have been obtained in IR than in Green [ C.Courde et al 2016 ]. In our study, in addition to the historical data obtained from various other LLR sites, we include the recent IR normal points obtained from Calern over the 1 year time span (2015-2016), constituting about 4.2% of data spread over 46 years of LLR. Near even distribution of data provided by IR on both the spatial and temporal domain, helps us to improve constraints on the internal structure of the Moon modeled within the planetary ephemeris : INPOP [ Fienga et al 2015 ]. IERS recommended models have been used in the data reduction software GINS (GRGS,CNES) [ V.Viswanathan et al 2015 ]. Constraints provided by GRAIL, on the Lunar gravitational potential and Love numbers have been taken into account in the least-square fit procedure. New estimates on the dynamical parameters of the lunar core will be presented.
NASA Astrophysics Data System (ADS)
Xu, Beilei; Zhang, Guijun; Xu, Changhua; Sun, Suqin
2015-09-01
Fourier transform infrared spectroscopy (FT-IR) associated with second derivative infrared spectroscopy (SD-IR) and two-dimensional correlation infrared spectroscopy (2D-IR) are employed to analyze various processed products and different extracts of Rhizoma Coptidis. There is a shift of the peak of 1641 cm-1 of raw Rhizoma Coptidis after processed, which drifts to lower wave number. Peaks at 1508, 1387, 1363, 1332, 1274 and 1234 cm-1 barely change in most samples, except an obvious enhancement of these peaks after processed, suggesting that processed Rhizoma Coptidis may have higher content of berberine than raw material, which is corresponding to the results of correlation coefficients analysis. There are some differences in the absorption peaks in the range of 1800-1000 cm-1 in the SD-IR spectra, which have better resolution, of different processed products. 2D-IR spectra, which elevate the resolution further, can present more differences among the products in the range of 1300-800 cm-1 and 1800-1300 cm-1. Analysis of aqueous, ethanol and petroleum ether extracts of various processed products proves that there are distinctive differences of all auto-peaks in shapes and intensities in all of them. With the advantages of high resolution, high speed and convenience, FT-IR combined with 2D-IR can quickly and precisely distinguish various processed products of Rhizoma Coptidis and can be applied to predict the tendency of transformation of the complicated chemical mixture systems under heat perturbation.
de Blaquière, Gail E; May, Felicity E B; Westley, Bruce R
2009-06-01
Insulin-like growth factors (IGFs) are thought to promote tumour progression and metastasis in part by stimulating cell migration. Insulin receptor substrate-1 (IRS-1) and IRS-2 are multisite docking proteins positioned immediately downstream from the type I IGF and insulin receptors. IRS-2 but not IRS-1 has been reported to be involved in the migratory response of breast cancer cells to IGFs. The purpose of this investigation was to determine if IRS-1 is involved in, and to assess the contributions of IRS-1 and IRS-2 to, the migratory response of breast cancer cells to IGFs. The expression of IRS-1 and IRS-2 varied considerably between ten breast cancer cell lines. Oestrogen increases expression of the type I IGF receptor, IRS-1 and IRS-2 in MCF-7 and ZR-75 cells. Oestrogens may control the sensitivity of breast cancer cells to IGFs by regulating the expression of components of the IGF signal transduction pathway. The migratory response to a range of IGF-1 concentrations was measured in MCF-7 and MDA-MB-231 breast cancer cells in which IRS-1 and IRS-2 levels were modulated using a doxycycline-inducible expression system. Induction of both IRS-1 and IRS-2 expression increased the sensitivity of the migratory response to IGF-1 but did not increase the magnitude of the response stimulated at higher concentrations of IGF-1. Knockdown of IRS-1, IRS-2 and the type I IGF receptor in MCF-7 and MDA-MB-2231 cells decreased sensitivity to IGF-1. We conclude that both IRS-1 and IRS-2 control the migratory response of breast cancer cells to IGF-1 and may, therefore, be key molecules in determining breast cancer spread.
Semiannual Report to the Congress. April 1, 2012 - September 30, 2012
2012-10-01
community for the ir professionalism a nd devotion to the mission. We thank the soldiers, Marin es, sailors, and airmen whose service and sacrifice...were ordered to pay $43,806 and $25,504 to the IRS , respectively. Seven Guilty Pleas in Wide-Ranging Bribery Scheme at Naval Air Station North Island...Calif. Overview: A joint investigation with the FBI, NCIS, IRS -Criminal Investigation and the Gen- eral Services Administration OIG identified a
Noninvasive Thermal Ablation of Osteomyelitis-Causing Bacteria using Functionalized Nanoparticles
2012-03-01
2008). One alternative approach to antibiotics includes the use of near infrared ( IR ) radiation to thermally kill pathogenic organisms (Kam, 2005...Zharov, 2006). Whereas near IR wavelengths pass harmlessly through the human body, they are known to heat gold nanoshells to high temperatures (>70°C...nanoparticles both alone and complexed with PlyCB (Fig. 8). Task 3. Determine depth of IR radiation penetration and range of thermal damage. (months 11- 15
A dual-waveband dynamic IR scene projector based on DMD
NASA Astrophysics Data System (ADS)
Hu, Yu; Zheng, Ya-wei; Gao, Jiao-bo; Sun, Ke-feng; Li, Jun-na; Zhang, Lei; Zhang, Fang
2016-10-01
Infrared scene simulation system can simulate multifold objects and backgrounds to perform dynamic test and evaluate EO detecting system in the hardware in-the-loop test. The basic structure of a dual-waveband dynamic IR scene projector was introduced in the paper. The system's core device is an IR Digital Micro-mirror Device (DMD) and the radiant source is a mini-type high temperature IR plane black-body. An IR collimation optical system which transmission range includes 3-5μm and 8-12μm is designed as the projection optical system. Scene simulation software was developed with Visual C++ and Vega soft tools and a software flow chart was presented. The parameters and testing results of the system were given, and this system was applied with satisfying performance in an IR imaging simulation testing.
Radical protection by differently composed creams in the UV/VIS and IR spectral ranges.
Meinke, Martina C; Syring, Felicia; Schanzer, Sabine; Haag, Stefan F; Graf, Rüdiger; Loch, Manuela; Gersonde, Ingo; Groth, Norbert; Pflücker, Frank; Lademann, Jürgen
2013-01-01
Modern sunscreens are well suited to provide sufficient protection in the UV range because the filter substances absorb or scatter UV radiation. Although up to 50% of radicals are formed in the visible and infrared spectral range during solar radiation protection strategies are not provided in this range. Previous investigations of commercially available products have shown that in addition to physical filters, antioxidants (AO) are necessary to provide protective effects in the infrared range by neutralizing already formed radicals. In this study, the efficacy of filter substances and AO to reduce radical formation in both spectral ranges was investigated after UV/VIS or IR irradiation. Optical properties and radical protection were determined for the investigated creams. It was found that organic UV filters lower radical formation in the UV/VIS range to 35% compared to untreated skin, independent of the presence of AO. Further reduction to 14% was reached by addition of 2% physical filters, whereas physical filters alone were ineffective in the UV/VIS range due to the low concentration. In contrast, this filter type reduced radical formation in the IR range significantly to 65%; similar effects were aroused after application of AO. Sunscreens which contain organic UV filters, physical filters and AO ensure protection in the complete solar spectrum. © 2013 The American Society of Photobiology.
NASA Technical Reports Server (NTRS)
Hansell, R. A., Jr.; Reid, J. S.; Tsay, S. C.; Roush, T. L.; Kalashnikova, O. V.
2011-01-01
To determine a plausible range of mass extinction efficiencies (MEE) of terrestrial atmospheric dust from the near to thermal IR, sensitivity analyses are performed over an extended range of dust microphysical and chemistry perturbations. The IR values are subsequently compared to those in the near-IR, to evaluate spectral relationships in their optical properties. Synthesized size distributions consistent with measurements, model particle size, while composition is defined by the refractive indices of minerals routinely observed in dust, including the widely used OPAC/Hess parameterization. Single-scattering properties of representative dust particle shapes are calculated using the T-matrix, Discrete Dipole Approximation and Lorenz-Mie light-scattering codes. For the parameterizations examined, MEE ranges from nearly zero to 1.2 square meters per gram, with the higher values associated with non-spheres composed of quartz and gypsum. At near-IR wavelengths, MEE for non-spheres generally exceeds those for spheres, while in the thermal IR, shape-induced changes in MEE strongly depend on volume median diameter (VMD) and wavelength, particularly for MEE evaluated at the mineral resonant frequencies. MEE spectral distributions appear to follow particle geometry and are evidence for shape dependency in the optical properties. It is also shown that non-spheres best reproduce the positions of prominent absorption peaks found in silicates. Generally, angular particles exhibit wider and more symmetric MEE spectral distribution patterns from 8-10 micrometers than those with smooth surfaces, likely due to their edge-effects. Lastly, MEE ratios allow for inferring dust optical properties across the visible-IR spectrum. We conclude the MEE of dust aerosol are significant for the parameter space investigated, and are a key component for remote sensing applications and the study of direct aerosol radiative effects.
Pigments which reflect infrared radiation from fire
Berdahl, Paul H.
1998-01-01
Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer (.mu.m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 .mu.m or, for cool smoky fires, about 2 .mu.m to about 16 .mu.m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 .mu.m to about 2 .mu.m and thin leafing aluminum flake pigments.
Coherent infrared imaging camera (CIRIC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchinson, D.P.; Simpson, M.L.; Bennett, C.A.
1995-07-01
New developments in 2-D, wide-bandwidth HgCdTe (MCT) and GaAs quantum-well infrared photodetectors (QWIP) coupled with Monolithic Microwave Integrated Circuit (MMIC) technology are now making focal plane array coherent infrared (IR) cameras viable. Unlike conventional IR cameras which provide only thermal data about a scene or target, a coherent camera based on optical heterodyne interferometry will also provide spectral and range information. Each pixel of the camera, consisting of a single photo-sensitive heterodyne mixer followed by an intermediate frequency amplifier and illuminated by a separate local oscillator beam, constitutes a complete optical heterodyne receiver. Applications of coherent IR cameras are numerousmore » and include target surveillance, range detection, chemical plume evolution, monitoring stack plume emissions, and wind shear detection.« less
Biological effects and medical applications of infrared radiation
Tsai, Shang-Ru; Hamblin, Michael R
2017-01-01
Infrared (IR) radiation is electromagnetic radiation with wavelengths between 760 nm and 100,000 nm. Low-level light therapy (LLLT) or photobiomodulation (PBM) therapy generally employs light at red and near-infrared wavelengths (600–100 nm) to modulate biological activity. Many factors, conditions, and parameters influence the therapeutic effects of IR, including fluence, irradiance, treatment timing and repetition, pulsing, and wavelength. Increasing evidence suggests that IR can carry out photostimulation and photobiomodulation effects particularly benefiting neural stimulation, wound healing, and cancer treatment. Nerve cells respond particularly well to IR, which has been proposed for a range of neurostimulation and neuromodulation applications, and recent progress in neural stimulation and regeneration are discussed in this review. The applications of IR therapy have moved on rapidly in recent years. For example, IR therapy has been developed that does not actually require an external power source, such as IR-emitting materials, and garments that can be powered by body heat alone. Another area of interest is the possible involvement of solar IR radiation in photoaging or photorejuvenation as opposites sides of the coin, and whether sunscreens should protect against solar IR? A better understanding of new developments and biological implications of IR could help us to improve therapeutic effectiveness or develop new methods of PBM using IR wavelengths. PMID:28441605
Biological effects and medical applications of infrared radiation.
Tsai, Shang-Ru; Hamblin, Michael R
2017-05-01
Infrared (IR) radiation is electromagnetic radiation with wavelengths between 760nm and 100,000nm. Low-level light therapy (LLLT) or photobiomodulation (PBM) therapy generally employs light at red and near-infrared wavelengths (600-100nm) to modulate biological activity. Many factors, conditions, and parameters influence the therapeutic effects of IR, including fluence, irradiance, treatment timing and repetition, pulsing, and wavelength. Increasing evidence suggests that IR can carry out photostimulation and photobiomodulation effects particularly benefiting neural stimulation, wound healing, and cancer treatment. Nerve cells respond particularly well to IR, which has been proposed for a range of neurostimulation and neuromodulation applications, and recent progress in neural stimulation and regeneration are discussed in this review. The applications of IR therapy have moved on rapidly in recent years. For example, IR therapy has been developed that does not actually require an external power source, such as IR-emitting materials, and garments that can be powered by body heat alone. Another area of interest is the possible involvement of solar IR radiation in photoaging or photorejuvenation as opposites sides of the coin, and whether sunscreens should protect against solar IR? A better understanding of new developments and biological implications of IR could help us to improve therapeutic effectiveness or develop new methods of PBM using IR wavelengths. Copyright © 2016. Published by Elsevier B.V.
Liu, Yan; Yu, Li; Jia, Xiaowen; Zhao, Jianzhou; Weng, Hongming; Peng, Yingying; Chen, Chaoyu; Xie, Zhuojin; Mou, Daixiang; He, Junfeng; Liu, Xu; Feng, Ya; Yi, Hemian; Zhao, Lin; Liu, Guodong; He, Shaolong; Dong, Xiaoli; Zhang, Jun; Xu, Zuyan; Chen, Chuangtian; Cao, Gang; Dai, Xi; Fang, Zhong; Zhou, X. J.
2015-01-01
The low energy electronic structure of Sr2IrO4 has been well studied and understood in terms of an effective Jeff = 1/2 Mott insulator model. However, little work has been done in studying its high energy electronic behaviors. Here we report a new observation of the anomalous high energy electronic structure in Sr2IrO4. By taking high-resolution angle-resolved photoemission measurements on Sr2IrO4 over a wide energy range, we have revealed for the first time that the high energy electronic structures show unusual nearly-vertical bands that extend over a large energy range. Such anomalous high energy behaviors resemble the high energy waterfall features observed in the cuprate superconductors. While strong electron correlation plays an important role in producing high energy waterfall features in the cuprate superconductors, the revelation of the high energy anomalies in Sr2IrO4, which exhibits strong spin-orbit coupling and a moderate electron correlation, points to an unknown and novel route in generating exotic electronic excitations. PMID:26267653
Evaluation of window-tinting films for sunlight phototherapy.
Vreman, Hendrik J; Slusher, Tina M; Wong, Ronald J; Schulz, Stephanie; Olusanya, Bolajoko O; Stevenson, David K
2013-12-01
We evaluated nine semi-transparent plastic window-tinting films for their ability to block ultraviolet A (UVA) and infrared (IR) radiation and transmit therapeutic blue light (400-520 nm) for treating jaundiced newborns. For indoor testing, three light sources (TL/52 special blue fluorescent, Black Light UVA and IR heat lamps) were positioned above each film and measured successively using a thermocouple thermometer, UVA radiometer and blue light irradiance meter, placed below each film. For outdoor testing, the same setup was used with the sun at zenith and a cloudless sky. Compared with unfiltered radiation, blue light transmission through films ranged from 24 to 83%, UVA transmission was 0.1-7.1% and reductions in IR heat were 6-12°C and 5-10°C for heat lamp and sun, respectively. The data suggest that most of the relatively low-cost window-tinting films tested can effectively reduce sunlight UV and IR and offer a range of significant attenuations of therapeutic blue light.
Moreno-Pérez, V.; Elvira, JLL.; Fernandez-Fernandez, J.; Vera-Garcia, FJ.
2018-01-01
Background Glenohumeral internal rotation deficit and external rotation strength have been associated with the development of shoulder pain in overhead athletes. Objective To examine the bilateral passive shoulder rotational range of motion (ROM), the isometric rotational strength and unilateral serve speed in elite tennis players with and without shoulder pain history (PH and NPH, respectively) and compare between dominant and non-dominant limbs and between groups. Study Design Cohort study. Methods Fifty-eight elite tennis players were distributed into the PH group (n = 20) and the NPH group (n = 38). Serve velocity, dominant and non-dominant passive shoulder external and internal rotation (ER and IR) ROM, total arc of motion (TAM: the sum of IR and ER ROM), ER and IR isometric strength, bilateral deficits and ER/IR strength ratio were measured in both groups. Questionnaires were administered in order to classify characteristics of shoulder pain. Results The dominant shoulder showed significantly reduced IR ROM and TAM, and increased ER ROM compared to the non-dominant shoulder in both groups. Isometric ER strength and ER/IR strength ratio were significantly lower in the dominant shoulder in the PH group when compared with the NPH group. No significant differences between groups were found for serve speed. Conclusion These data show specific adaptations in the IR, TAM and ER ROM in the dominant shoulder in both groups. Isometric ER muscle weakness and ER/IR strength ratio deficit appear to be associated with history of shoulder injuries in elite tennis players. It would be advisable for clinicians to use the present information to design injury prevention programs. Level of evidence 2 PMID:29484240
Moreno-Pérez, V; Elvira, Jll; Fernandez-Fernandez, J; Vera-Garcia, F J
2018-02-01
Glenohumeral internal rotation deficit and external rotation strength have been associated with the development of shoulder pain in overhead athletes. To examine the bilateral passive shoulder rotational range of motion (ROM), the isometric rotational strength and unilateral serve speed in elite tennis players with and without shoulder pain history (PH and NPH, respectively) and compare between dominant and non-dominant limbs and between groups. Cohort study. Fifty-eight elite tennis players were distributed into the PH group (n = 20) and the NPH group (n = 38). Serve velocity, dominant and non-dominant passive shoulder external and internal rotation (ER and IR) ROM, total arc of motion (TAM: the sum of IR and ER ROM), ER and IR isometric strength, bilateral deficits and ER/IR strength ratio were measured in both groups. Questionnaires were administered in order to classify characteristics of shoulder pain. The dominant shoulder showed significantly reduced IR ROM and TAM, and increased ER ROM compared to the non-dominant shoulder in both groups. Isometric ER strength and ER/IR strength ratio were significantly lower in the dominant shoulder in the PH group when compared with the NPH group. No significant differences between groups were found for serve speed. These data show specific adaptations in the IR, TAM and ER ROM in the dominant shoulder in both groups. Isometric ER muscle weakness and ER/IR strength ratio deficit appear to be associated with history of shoulder injuries in elite tennis players. It would be advisable for clinicians to use the present information to design injury prevention programs. 2.
Rudolff, Andrea S; Moens, Yves P S; Driessen, Bernd; Ambrisko, Tamas D
2014-07-01
To assess agreement between infrared (IR) analysers and a refractometer for measurements of isoflurane, sevoflurane and desflurane concentrations and to demonstrate the effect of customized calibration of IR analysers. In vitro experiment. Six IR anaesthetic monitors (Datex-Ohmeda) and a single portable refractometer (Riken). Both devices were calibrated following the manufacturer's recommendations. Gas samples were collected at common gas outlets of anaesthesia machines. A range of agent concentrations was produced by stepwise changes in dial settings: isoflurane (0-5% in 0.5% increments), sevoflurane (0-8% in 1% increments), or desflurane (0-18% in 2% increments). Oxygen flow was 2 L minute(-1) . The orders of testing IR analysers, agents and dial settings were randomized. Duplicate measurements were performed at each setting. The entire procedure was repeated 24 hours later. Bland-Altman analysis was performed. Measurements on day-1 were used to yield calibration equations (IR measurements as dependent and refractometry measurements as independent variables), which were used to modify the IR measurements on day-2. Bias ± limits of agreement for isoflurane, sevoflurane and desflurane were 0.2 ± 0.3, 0.1 ± 0.4 and 0.7 ± 0.9 volume%, respectively. There were significant linear relationships between differences and means for all agents. The IR analysers became less accurate at higher gas concentrations. After customized calibration, the bias became almost zero and the limits of agreement became narrower. If similar IR analysers are used in research studies, they need to be calibrated against a reference method using the agent in question at multiple calibration points overlapping the range of interest. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Harput, Gulcan; Guney, Hande; Toprak, Ugur; Colakoglu, Filiz; Baltaci, Gul
2017-11-01
There is limited information in the literature that shows whether scapular taping has an effect on the acromiohumeral distance (AHD) and shoulder functions. The aim of this study was to investigate the acute effects of scapular Kinesio Taping® on shoulder internal rotation (IR) and external rotation (ER) strength, IR and ER range of motion (ROM) and AHD in asymptomatic overhead athletes. Forty-one volleyball athletes (24 men, 17 women; mean age: 16.1±1.5 years, body mass: 66.5±9.6 kg, body height: 179.6±8.4 cm, Body Mass Index: 20.5±2.3 kg/m2, time participating in overhead sports activity: 6.2±1.4 h/week, experience in sport: 4.1±2.4 years) were included in this study. Shoulder IR and ER ROM, total rotation ROM, AHD, shoulder isometric IR and ER strength and ER:IR strength ratio of the dominant side were tested before and after taping. Scapular taping increased the shoulder IR (P<0.001) and total ROM (P<0.001), AHD (P<0.001), shoulder IR (P=0.002) and ER (P=0.006) strength. ER ROM and ER:IR ratio did not change after taping (P=0.26, P=0.98, respectively). The results of this study suggest that scapular taping could be an effective method for enhancing the acromiohumeral distance, shoulder rotator strength and range of motion. Therefore, scapular taping could be recommended for not only in the asymptomatic athletes' shoulder exercise training but also in the prevention of subacromial impingement syndrome.
MTF measurement of IR optics in different temperature ranges
NASA Astrophysics Data System (ADS)
Bai, Alexander; Duncker, Hannes; Dumitrescu, Eugen
2017-10-01
Infrared (IR) optical systems are at the core of many military, civilian and manufacturing applications and perform mission critical functions. To reliably fulfill the demanding requirements imposed on today's high performance IR optics, highly accurate, reproducible and fast lens testing is of crucial importance. Testing the optical performance within different temperature ranges becomes key in many military applications. Due to highly complex IR-Applications in the fields of aerospace, military and automotive industries, MTF Measurement under realistic environmental conditions become more and more relevant. A Modulation Transfer Function (MTF) test bench with an integrated thermal chamber allows measuring several sample sizes in a temperature range from -40 °C to +120°C. To reach reliable measurement results under these difficult conditions, a specially developed temperature stable design including an insulating vacuum are used. The main function of this instrument is the measurement of the MTF both on- and off-axis at up to +/-70° field angle, as well as measurement of effective focal length, flange focal length and distortion. The vertical configuration of the system guarantees a small overall footprint. By integrating a high-resolution IR camera with focal plane array (FPA) in the detection unit, time consuming measurement procedures such as scanning slit with liquid nitrogen cooled detectors can be avoided. The specified absolute accuracy of +/- 3% MTF is validated using internationally traceable reference optics. Together with a complete and intuitive software solution, this makes the instrument a turn-key device for today's state-of- the-art optical testing.
Range estimation of passive infrared targets through the atmosphere
NASA Astrophysics Data System (ADS)
Cho, Hoonkyung; Chun, Joohwan; Seo, Doochun; Choi, Seokweon
2013-04-01
Target range estimation is traditionally based on radar and active sonar systems in modern combat systems. However, jamming signals tremendously degrade the performance of such active sensor devices. We introduce a simple target range estimation method and the fundamental limits of the proposed method based on the atmosphere propagation model. Since passive infrared (IR) sensors measure IR signals radiating from objects in different wavelengths, this method has robustness against electromagnetic jamming. The measured target radiance of each wavelength at the IR sensor depends on the emissive properties of target material and various attenuation factors (i.e., the distance between sensor and target and atmosphere environment parameters). MODTRAN is a tool that models atmospheric propagation of electromagnetic radiation. Based on the results from MODTRAN and atmosphere propagation-based modeling, the target range can be estimated. To analyze the proposed method's performance statistically, we use maximum likelihood estimation (MLE) and evaluate the Cramer-Rao lower bound (CRLB) via the probability density function of measured radiance. We also compare CRLB and the variance of MLE using Monte-Carlo simulation.
Radiance and atmosphere propagation-based method for the target range estimation
NASA Astrophysics Data System (ADS)
Cho, Hoonkyung; Chun, Joohwan
2012-06-01
Target range estimation is traditionally based on radar and active sonar systems in modern combat system. However, the performance of such active sensor devices is degraded tremendously by jamming signal from the enemy. This paper proposes a simple range estimation method between the target and the sensor. Passive IR sensors measures infrared (IR) light radiance radiating from objects in dierent wavelength and this method shows robustness against electromagnetic jamming. The measured target radiance of each wavelength at the IR sensor depends on the emissive properties of target material and is attenuated by various factors, in particular the distance between the sensor and the target and atmosphere environment. MODTRAN is a tool that models atmospheric propagation of electromagnetic radiation. Based on the result from MODTRAN and measured radiance, the target range is estimated. To statistically analyze the performance of proposed method, we use maximum likelihood estimation (MLE) and evaluate the Cramer-Rao Lower Bound (CRLB) via the probability density function of measured radiance. And we also compare CRLB and the variance of and ML estimation using Monte-Carlo.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veiga, L. S. I.; Etter, M.; Glazyrin, K.
Here, we explore the response of Ir 5d orbitals to pressure in β-Li 2IrO 3, a hyperhoneycomb iridate in proximity to a Kitaev quantum spin-liquid (QSL) ground state. X-ray absorption spectroscopy reveals a reconstruction of the electronic ground state below 2 GPa, the same pressure range where x-ray magnetic circular dichroism shows an apparent collapse of magnetic order. The electronic reconstruction, which manifests a reduction in the effective spin-orbit interaction in 5d orbitals, pushes β-Li 2IrO 3 further away from the pure J eff = 1/2 limit. Although lattice symmetry is preserved across the electronic transition, x-ray diffraction shows amore » highly anisotropic compression of the hyperhoneycomb lattice which affects the balance of bond-directional Ir-Ir exchange interactions driven by spin-orbit coupling at Ir sites. An enhancement of symmetric anisotropic exchange over Kitaev and Heisenberg exchange interactions seen in theoretical calculations that use precisely this anisotropic Ir-Ir bond compression provides one possible route to the realization of a QSL state in this hyperhoneycomb iridate at high pressures.« less
NASA Astrophysics Data System (ADS)
Mao, Yifei; Zhang, Jijun; Lin, Liwen; Lai, Jianming; Min, Jiahua; Liang, Xiaoyan; Huang, Jian; Tang, Ke; Wang, Linjun
2018-04-01
Different wavelength IR light (770-1150 nm) was used to evaluate the effect of IR light on the carrier transport performance of CdZnTe detector. The effective mobility-lifetime product (μτ*) of CdZnTe achieved 10-2 cm2 V-1 when the IR wavelength was in the range of 820-920 nm, but decreased to 1 × 10-4 cm2 V-1 when the wavelength was longer than 920 nm. The mechanism about how IR light affecting the carrier transport property of CdZnTe detector was analyzed with Shockley-Read-Hall model. The defect of doubly ionized Cd vacancy ([VCd]2-) was found to be the main factor that assist IR light affecting the μτ of CdZnTe detector. The photoconductive experiment under 770-1150 nm IR illumination was carried out, and three kinds of photocurrent curve were detected and analyzed by solving the Hecht equation. The experiments demonstrated the effect of [VCd]2- defect on the carrier transport property of CdZnTe detector under IR illumination.
Oei, Ju Lee; Abdel-Latif, Mohamed E; Craig, Fiona; Kee, Aivy; Austin, Marie-Paule; Lui, Kei
2009-04-01
The aim of the present study was to determine the characteristics and short-term outcomes of mother-infant pairs with comorbid drug dependency and psychiatric disorders. A population-based retrospective chart review was carried out of 879 drug-dependent mother and infant pairs in New South Wales (NSW) and the Australian Capital Territory (ACT) who delivered between 1 January and 31 December 2004. Psychiatric comorbidity (dual diagnosis, DD) was identified in 396 (45%) of the 879 drug-dependent women. DSM-IV depression (79%), followed by anxiety (20%), was most prevalent. DD women were more likely to use amphetamines (29% vs 18%, p < 0.05), less likely to use opiates (42% vs 51%, p < 0.05) and to have had no antenatal care (24% vs 8%, p < 0.05). They also had more previous pregnancies (4, range = 2-5 vs 3, range = 2-5, p < 0.05) and domestic violence (29% vs 14%, p < 0.05) was more common. DD infants were less likely to be admitted to a nursery (47% vs 55%, p < 0.05). Withdrawal scores were similar (maximum median Finnegan scores = 4 (interquartile range = 3-8) vs 10 (interquartile range = 7-12, p = 0.30) but fewer needed withdrawal medication (19% vs 27%, p < 0.05). Maternal psychotropic agents did not worsen the severity of neonatal withdrawal. Psychiatric comorbidity, especially depression, is common and affects almost half of drug-using mothers. Antenatal care, drug use and social outcomes are worse for DD mothers and their infants. It is recommended that all drug-using women be assessed antenatally for psychosocial disorders so that timely mental health intervention can be offered, if required.
de Waard, Claudia S; Poot, Antonius J; den Elzen, Wendy P J; Wind, Annet W; Caljouw, Monique A A; Gussekloo, Jacobijn
2018-06-01
Understanding patient satisfaction from the perspective of older adults is important to improve quality of their care. Since patient and care variables which can be influenced are of specific interest, this study examines the relation between patient satisfaction and the perceived doctor-patient relationship in older persons and their general practitioners (GPs). Cross-sectional survey. Older persons (n = 653, median age 87 years; 69.4% female) living in 41 residential homes. Patient satisfaction (report mark) and perceived doctor-patient relationship (Leiden Perioperative care Patient Satisfaction questionnaire); relationships were examined by comparing medians and use of regression models. The median satisfaction score was 8 (interquartile range 7.5-9; range 0-10) and doctor-patient relationship 65 (interquartile range 63-65; range 13-65). Higher satisfaction scores were related to higher scores on doctor-patient relationship (Jonckheere Terpstra test, p for trend <.001) independent of gender, age, duration of stay in the residential home, functional and clinical characteristics. Adjusted for these characteristics, per additional point for doctor-patient relationship, satisfaction increased with 0.103 points (β = 0.103, 95% CI 0.092-0.114; p < .001). In those with a 'low' doctor-patient relationship rating, the percentage awarding 'sufficient or good' to their GP for 'understanding about the personal situation' was 12%, 'receiving attention as an individual' 22%, treating the patient kindly 78%, and being polite 94%. In older persons, perceived doctor-patient relationship and patient satisfaction are related, irrespective of patient characteristics. GPs may improve patient satisfaction by focusing more on the affective aspects of the doctor-patient relationship. Key Points Examination of the perceived doctor-patient relationship as a variable might better accommodate patients' expectations and improve satisfaction with the provided primary care.
Increased prevalence of gallbladder polyps in acromegaly.
Annamalai, Anand K; Gayton, Emma L; Webb, Alison; Halsall, David J; Rice, Caiomhe; Ibram, Ferda; Chaudhry, Afzal N; Simpson, Helen L; Berman, Laurence; Gurnell, Mark
2011-07-01
Several studies have suggested an increased prevalence of benign and malignant tumors in acromegaly, particularly colonic neoplasms. The gallbladder's epithelial similarity to the colon raises the possibility that gallbladder polyps (GBP) may occur more frequently in acromegaly. Thirty-one patients with newly diagnosed acromegaly (14 females, 17 males; mean age 54.7 yr, range 27-76 yr) were referred to our center between 2004 and 2008. All had pituitary adenomas and were treated with somatostatin analogs prior to transsphenoidal surgery. Biliary ultrasonography was performed at the time of referral. In a retrospective case-cohort study, we compared the prevalence of GBP in these scans with those of 13,234 consecutive patients (age range 20-80 yr) presenting at the hospital for abdominal/biliary ultrasound during the same time interval. Associations between GH and IGF-I levels and GBP in acromegaly were also examined. There was a higher prevalence of GBP in patients with acromegaly compared with controls (29.03 vs 4.62%, P = 0.000008); relative risk was 6.29 (95% confidence interval 3.61-10.96). Eight of nine patients with acromegaly and GBP were older than 50 yr of age. GH levels were higher in those with GBP (median 30.8 μg/liter, interquartile range 10.9-39.1) than those without (8.2 μg/liter, interquartile range 6.0-16.0), but IGF-I levels were comparable. This is the first study to demonstrate an increased prevalence of GBP in patients with newly diagnosed acromegaly. Further studies are required to determine whether these patients are at increased risk of developing gallbladder carcinoma and to define the role, if any, of biliary ultrasound surveillance.
NASA Astrophysics Data System (ADS)
Denis-Bacelar, Ana M.; Chittenden, Sarah J.; Murray, Iain; Divoli, Antigoni; McCready, V. Ralph; Dearnaley, David P.; O'Sullivan, Joe M.; Johnson, Bernadette; Flux, Glenn D.
2017-04-01
Skeletal tumour burden is a biomarker of prognosis and survival in cancer patients. This study proposes a novel method based on the linear quadratic model to predict the reduction in metastatic tumour burden as a function of the absorbed doses delivered from molecular radiotherapy treatments. The range of absorbed doses necessary to eradicate all the bone lesions and to reduce the metastatic burden was investigated in a cohort of 22 patients with bone metastases from castration-resistant prostate cancer. A metastatic burden reduction curve was generated for each patient, which predicts the reduction in metastatic burden as a function of the patient mean absorbed dose, defined as the mean of all the lesion absorbed doses in any given patient. In the patient cohort studied, the median of the patient mean absorbed dose predicted to reduce the metastatic burden by 50% was 89 Gy (interquartile range: 83-105 Gy), whilst a median of 183 Gy (interquartile range: 107-247 Gy) was found necessary to eradicate all metastases in a given patient. The absorbed dose required to eradicate all the lesions was strongly correlated with the variability of the absorbed doses delivered to multiple lesions in a given patient (r = 0.98, P < 0.0001). The metastatic burden reduction curves showed a potential large reduction in metastatic burden for a small increase in absorbed dose in 91% of patients. The results indicate the range of absorbed doses required to potentially obtain a significant survival benefit. The metastatic burden reduction method provides a simple tool that could be used in routine clinical practice for patient selection and to indicate the required administered activity to achieve a predicted patient mean absorbed dose and reduction in metastatic tumour burden.
Out-of-pocket costs for childhood stroke: the impact of chronic illness on parents' pocketbooks.
Plumb, Patricia; Seiber, Eric; Dowling, Michael M; Lee, JoEllen; Bernard, Timothy J; deVeber, Gabrielle; Ichord, Rebecca N; Bastian, Rachel; Lo, Warren D
2015-01-01
Direct costs for children who had stroke are similar to those for adults. There is no information regarding the out-of-pocket costs families encounter. We described the out-of-pocket costs families encountered in the first year after a child's ischemic stroke. Twenty-two subjects were prospectively recruited at four centers in the United States and Canada in 2008 and 2009 as part of the "Validation of the Pediatric NIH Stroke Scale" study; families' indirect costs were tracked for 1 year. Every 3 months, parents reported hours they did not work, nonreimbursed costs for medical visits or other health care, and mileage. They provided estimates of annual income. We calculated total out-of-pocket costs in US dollars and reported costs as a proportion of annual income. Total median out-of-pocket cost for the year after an ischemic stroke was $4354 (range, $0-$28,666; interquartile range, $1008-$8245). Out-of-pocket costs were greatest in the first 3 months after the incident stroke, with the largest proportion because of lost wages, followed by transportation, and nonreimbursed health care. For the entire year, median costs represented 6.8% (range, 0%-81.9%; interquartile range, 2.7%-17.2%) of annual income. Out-of-pocket expenses are significant after a child's ischemic stroke. The median costs are noteworthy provided that the median American household had cash savings of $3650 at the time of the study. These results with previous reports of direct costs provide a more complete view of the overall costs to families and society. Childhood stroke creates an under-recognized cost to society because of decreased parental productivity. Copyright © 2015 Elsevier Inc. All rights reserved.
Gupta, Ayush; Kapil, Arti; Kabra, S K; Lodha, Rakesh; Sood, Seema; Dhawan, Benu; Das, Bimal K; Sreenivas, V
2013-12-01
Healthcare associated infections (HAIs) are responsible for morbidity and mortality among immunocompromised and critically ill patients. We undertook this study to estimate the burden of HAIs in the paediatric cancer patients in a tertiary care hospital in north India. This prospective, observational study, based on active surveillance for a period of 11 months was undertaken in a 4-bedded isolated, cubicle for paediatric cancer patients. Patients who stayed in the cubicle for ≥48 h, were followed prospectively for the development of HAIs. Of the 138 patients, 13 developed 14 episodes of HAIs during the study period. Patient-days calculated were 1273 days. Crude infection rate (CIR) and incidence density (ID) of all HAIs were 9.4/100 patients and 11/1000 patient-days, respectively. Of the 14 episodes of HAIs, seven (50%) were of blood stream infections (HA-BSI), five (36%) of pneumonia (HAP) and two (14%) urinary tract infections (HA-UTI). The CIRs of HA-BSI, HAP and HA-UTI were 5.1, 3.6 and 1.4/100 patients, respectively. The corresponding IDs were 5.5, 3.9 and 1.6/1000 patient-days, respectively. Mean length of stay was significantly higher in patients who developed an HAI [13.8 (range 7-30), median (Interquartile range) 12 (11-14)] vs 7.5 days [range 2-28, median (interquartile range) 7 (5-9); P<0.0001]. Also mortality was significantly higher in patients who developed an HAI [23% (3/13) vs 3% (4/125), P<0.05]. The incidence of HAIs in the paediatric cancer patients in the study was 11/1000 patient days, of which HA-BSIs were the commonest. HAIs were associated with an increase in morbidity and mortality amongst this high risk patient population.
Review of infrared technology in The Netherlands
NASA Astrophysics Data System (ADS)
de Jong, Arie N.
1993-11-01
The use of infrared sensors in the Netherlands is substantial. Users can be found in a variety of disciplines, military as well as civil. This need for IR sensors implied a long history on IR technology and development. The result was a large technological-capability allowing the realization of IR hardware: specialized measuring equipment, engineering development models, prototype and production sensors for different applications. These applications range from small size, local radiometry up to large space-borne imaging. Large scale production of IR sensors has been realized for army vehicles. IR sensors have been introduced now in all of the armed forces. Facilities have been built to test the performance of these sensors. Models have been developed to predict the performance of a new sensor. A great effort has been spent on atmospheric research, leading to knowledge upon atmospheric- and background limitations of IR sensors.
NASA Astrophysics Data System (ADS)
Chan, Kenneth H.; Tom, Henry; Darling, Cynthia L.; Fried, Daniel
2015-02-01
Previous studies have established that caries lesions can be imaged with high contrast without the interference of stains at near-IR wavelengths greater than 1300-nm. It has been demonstrated that computer controlled laser scanning systems utilizing IR lasers operating at high pulse repetition rates can be used for serial imaging and selective removal of caries lesions. In this study, we report our progress towards the development of algorithms for generating rasterized ablation maps from near-IR reflectance images for the removal of natural lesions from tooth occlusal surfaces. An InGaAs camera and a filtered tungsten-halogen lamp producing near-IR light in the range of 1500-1700-nm were used to collect crosspolarization reflectance images of tooth occlusal surfaces. A CO2 laser operating at a wavelength of 9.3- μm with a pulse duration of 10-15-μs was used for image-guided ablation.
Noncontact localized internal infrared radiation measurement using an infrared point detector
NASA Astrophysics Data System (ADS)
Hisaka, Masaki
2017-12-01
The techniques for temperature measurement within the human body are important for clinical applications. A method for noncontact local infrared (IR) radiation measurements was investigated deep within an object to simulate how the core human body temperature can be obtained. To isolate the IR light emitted from a specific area within the object from the external noise, the radiating IR light was detected using an IR point detector, which comprises a pinhole and a thermopile positioned at an imaging relation with the region of interest within the object. The structure of the helical filament radiating IR light inside a light bulb was thermally imaged by scanning the bulb in two dimensions. Moreover, this approach was used to effectively measure IR light in the range of human body temperature using a glass plate placed in front of the heat source, mimicking the ocular fundus.
Comparative studies on cervical and colonic malignancies using FTIR microspectroscopy
NASA Astrophysics Data System (ADS)
Mordechai, Shaul; Mark, Shlomo; Podshyvalov, A.; Kantarovich, Keren; Bernshtain, Y.; Salman, Ahmad; Erukhimovitch, Vitaly; Guterman, Hugo; Goldstein, Jed; Argov, Shmuel; Jagannathan, R.
2003-07-01
IR spectroscopy provides a new diagnostic tool due to its sensitivity to molecular composition and structure in cells, which accompany transformation from healthy to diseased state. The IR spectrum of a sample is, therefore, a biochemical fingerprint. It has been found that the most significant changes occur in the mid-IR spectral range 3-25 mm. Encouraging results have been reported in the literature on various types of cancers, such as human breast, lung, colon, cervical, and leukemia using FT-IR microspectroscopy. Much progress has also been made by several groups on IR spectral maps and IR imaging with good agreement between the data and the histopathological information. In an attempt to characterize healthy and diseased tissues, infrared microspectroscopy of cervical and colon human tissues was studied using an infrared microscopy. The comparative qualitative and quantitative changes detected using FTIR microspectroscopy are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowlan, Pamela Renee
2016-05-02
These are slides dealing with frontiers in chemical physics. The following topics are covered: Time resolving chemistry with ultrashort pulses in the 0.1-40 THz spectral range; Example: Mid-infrared absorption spectrum of the intermediate state CH 2OO; Tracking reaction dynamics through changes in the spectra; Single-shot measurement of the mid-IR absorption dynamics; Applying 2D coherent mid-IR spectroscopy to learn more about transition states; Time resolving chemical reactions at a catalysis using mid-IR and THz pulses; Studying topological insulators requires a surface sensitive probe; Nonlinear phonon dynamics in Bi 2Se 3; THz-pump, SHG-probe as a surface sensitive coherent 2D spectroscopy; Nanometer andmore » femtosecond spatiotemporal resolution mid-IR spectroscopy; Coherent two-dimensional THz/mid-IR spectroscopy with 10nm spatial resolution; Pervoskite oxides as catalysts; Functionalized graphene for catalysis; Single-shot spatiotemporal measurements; Spatiotemporal pulse measurement; Intense, broad-band THz/mid-IR generation with organic crystals.« less
Infrared Imaging Tools for Diagnostic Applications in Dermatology.
Gurjarpadhye, Abhijit Achyut; Parekh, Mansi Bharat; Dubnika, Arita; Rajadas, Jayakumar; Inayathullah, Mohammed
Infrared (IR) imaging is a collection of non-invasive imaging techniques that utilize the IR domain of the electromagnetic spectrum for tissue assessment. A subset of these techniques construct images using back-reflected light, while other techniques rely on detection of IR radiation emitted by the tissue as a result of its temperature. Modern IR detectors sense thermal emissions and produce a heat map of surface temperature distribution in tissues. Thus, the IR spectrum offers a variety of imaging applications particularly useful in clinical diagnostic area, ranging from high-resolution, depth-resolved visualization of tissue to temperature variation assessment. These techniques have been helpful in the diagnosis of many medical conditions including skin/breast cancer, arthritis, allergy, burns, and others. In this review, we discuss current roles of IR-imaging techniques for diagnostic applications in dermatology with an emphasis on skin cancer, allergies, blisters, burns and wounds.
Noncontact localized internal infrared radiation measurement using an infrared point detector
NASA Astrophysics Data System (ADS)
Hisaka, Masaki
2018-06-01
The techniques for temperature measurement within the human body are important for clinical applications. A method for noncontact local infrared (IR) radiation measurements was investigated deep within an object to simulate how the core human body temperature can be obtained. To isolate the IR light emitted from a specific area within the object from the external noise, the radiating IR light was detected using an IR point detector, which comprises a pinhole and a thermopile positioned at an imaging relation with the region of interest within the object. The structure of the helical filament radiating IR light inside a light bulb was thermally imaged by scanning the bulb in two dimensions. Moreover, this approach was used to effectively measure IR light in the range of human body temperature using a glass plate placed in front of the heat source, mimicking the ocular fundus.
Thermal weapon sights with integrated fire control computers: algorithms and experiences
NASA Astrophysics Data System (ADS)
Rothe, Hendrik; Graswald, Markus; Breiter, Rainer
2008-04-01
The HuntIR long range thermal weapon sight of AIM is deployed in various out of area missions since 2004 as a part of the German Future Infantryman system (IdZ). In 2007 AIM fielded RangIR as upgrade with integrated laser Range finder (LRF), digital magnetic compass (DMC) and fire control unit (FCU). RangIR fills the capability gaps of day/night fire control for grenade machine guns (GMG) and the enhanced system of the IdZ. Due to proven expertise and proprietary methods in fire control, fast access to military trials for optimisation loops and similar hardware platforms, AIM and the University of the Federal Armed Forces Hamburg (HSU) decided to team for the development of suitable fire control algorithms. The pronounced ballistic trajectory of the 40mm GMG requires most accurate FCU-solutions specifically for air burst ammunition (ABM) and is most sensitive to faint effects like levelling or firing up/downhill. This weapon was therefore selected to validate the quality of the FCU hard- and software under relevant military conditions. For exterior ballistics the modified point mass model according to STANAG 4355 is used. The differential equations of motions are solved numerically, the two point boundary value problem is solved iteratively. Computing time varies according to the precision needed and is typical in the range from 0.1 - 0.5 seconds. RangIR provided outstanding hit accuracy including ABM fuze timing in various trials of the German Army and allied partners in 2007 and is now ready for series production. This paper deals mainly with the fundamentals of the fire control algorithms and shows how to implement them in combination with any DSP-equipped thermal weapon sights (TWS) in a variety of light supporting weapon systems.
Controlling T c of Iridium films using interfacial proximity effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hennings-Yeomans, R; Chang, CL; Ding, J
High precision calorimetry using superconducting transition edge sensors requires the use of superconducting films with a suitable T c, depending on the application. To advance high-precision macrocalorimetry, we require low-T c films that are easy to fabricate. A simple and effective way to suppress T c of superconducting Iridium through the proximity effect is demonstrated by using Ir/Pt bilayers as well as Au/Ir/Au trilayers. While Ir/Au films fabricated by applying heat to the substrate during Ir deposition have been used in the past for superconducting sensors, we present results of T c suppression on Iridium by deposition at room temperature in Au/Ir/Au trilayers and Ir/Pt bilayers in the range ofmore » $$\\sim$$20-100~mK. Measurements of the relative impedance between the Ir/Pt bilayers and Au/Ir/Au trilayers fabricated show factor of $$\\sim$$10 higher values in the Ir/Pt case. These new films could play a key role in the development of scalable superconducting transition edge sensors that require low-T c films to minimize heat capacity and maximize energy resolution, while keeping high-yield fabrication methods.« less
Veiga, L. S. I.; Etter, M.; Glazyrin, K.; ...
2017-10-10
Here, we explore the response of Ir 5d orbitals to pressure in β-Li 2IrO 3, a hyperhoneycomb iridate in proximity to a Kitaev quantum spin-liquid (QSL) ground state. X-ray absorption spectroscopy reveals a reconstruction of the electronic ground state below 2 GPa, the same pressure range where x-ray magnetic circular dichroism shows an apparent collapse of magnetic order. The electronic reconstruction, which manifests a reduction in the effective spin-orbit interaction in 5d orbitals, pushes β-Li 2IrO 3 further away from the pure J eff = 1/2 limit. Although lattice symmetry is preserved across the electronic transition, x-ray diffraction shows amore » highly anisotropic compression of the hyperhoneycomb lattice which affects the balance of bond-directional Ir-Ir exchange interactions driven by spin-orbit coupling at Ir sites. An enhancement of symmetric anisotropic exchange over Kitaev and Heisenberg exchange interactions seen in theoretical calculations that use precisely this anisotropic Ir-Ir bond compression provides one possible route to the realization of a QSL state in this hyperhoneycomb iridate at high pressures.« less
NASA Astrophysics Data System (ADS)
Veiga, L. S. I.; Etter, M.; Glazyrin, K.; Sun, F.; Escanhoela, C. A.; Fabbris, G.; Mardegan, J. R. L.; Malavi, P. S.; Deng, Y.; Stavropoulos, P. P.; Kee, H.-Y.; Yang, W. G.; van Veenendaal, M.; Schilling, J. S.; Takayama, T.; Takagi, H.; Haskel, D.
2017-10-01
We explore the response of Ir 5 d orbitals to pressure in β -Li2IrO3 , a hyperhoneycomb iridate in proximity to a Kitaev quantum spin-liquid (QSL) ground state. X-ray absorption spectroscopy reveals a reconstruction of the electronic ground state below 2 GPa, the same pressure range where x-ray magnetic circular dichroism shows an apparent collapse of magnetic order. The electronic reconstruction, which manifests a reduction in the effective spin-orbit interaction in 5 d orbitals, pushes β -Li2IrO3 further away from the pure Jeff=1 /2 limit. Although lattice symmetry is preserved across the electronic transition, x-ray diffraction shows a highly anisotropic compression of the hyperhoneycomb lattice which affects the balance of bond-directional Ir-Ir exchange interactions driven by spin-orbit coupling at Ir sites. An enhancement of symmetric anisotropic exchange over Kitaev and Heisenberg exchange interactions seen in theoretical calculations that use precisely this anisotropic Ir-Ir bond compression provides one possible route to the realization of a QSL state in this hyperhoneycomb iridate at high pressures.
NASA Astrophysics Data System (ADS)
Kim, Sungho
2017-06-01
Automatic target recognition (ATR) is a traditionally challenging problem in military applications because of the wide range of infrared (IR) image variations and the limited number of training images. IR variations are caused by various three-dimensional target poses, noncooperative weather conditions (fog and rain), and difficult target acquisition environments. Recently, deep convolutional neural network-based approaches for RGB images (RGB-CNN) showed breakthrough performance in computer vision problems, such as object detection and classification. The direct use of RGB-CNN to the IR ATR problem fails to work because of the IR database problems (limited database size and IR image variations). An IR variation-reduced deep CNN (IVR-CNN) to cope with the problems is presented. The problem of limited IR database size is solved by a commercial thermal simulator (OKTAL-SE). The second problem of IR variations is mitigated by the proposed shifted ramp function-based intensity transformation. This can suppress the background and enhance the target contrast simultaneously. The experimental results on the synthesized IR images generated by the thermal simulator (OKTAL-SE) validated the feasibility of IVR-CNN for military ATR applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Soren A.; Dippo, Patricia; Mansfield, Lorelle M.
2016-11-21
We use two-wavelength excitation photoluminescence spectroscopy to probe defect states in CIGS thin films. Above-Eg excitation is combined with a tunable IR bias light that modulates the population of the defect states. We find that IR illumination in the range of 1400-2000 nm (0.62-0.89 eV) causes a reduction of the PL intensity, the magnitude of which scales linearly with IR power. Further, KF post deposition treatment has only a modest influence on the effect of the IR excitation. Initial data suggest that we have developed an optical characterization tool for band-gap defect states.
Achromatic wave plates for the mid-infrared
NASA Astrophysics Data System (ADS)
Beasley, J. Donald; Marlowe, Philip D.
2012-06-01
Achromatic wave plates are useful in various mid-IR applications, such as analyzing or controlling the spectrum available from CO2 and other lasers, and for the study of IR spectra from distant stars. Their production relies upon the technical skills of those who grow the required high quality crystals and upon those who fabricate the optical parts to the needed precision. Two materials are described - one useful for light in the spectral range of the visible through the near IR and another that functions well in mid-IR applications from 2.5 μm to 11.5 μm. Some limitations imposed by inherent material properties will also be discussed.
Soh, JunYi; Chueng, Adeline; Adio, Aminat; Cooper, Alan J; Birch, Brian R; Lwaleed, Bashir A
2013-04-01
Fourier transform infrared (FT-IR) imaging is increasingly being applied to biomedical specimens, but strong IR absorption by water complicates live cell imaging. This study investigates the viability of adherent epithelial cells maintained for short periods under mineral oils in order to facilitate live cell spectroscopy using FT-IR with subsequent imaging. The MGH-U1 urothelial or CaCo2 colorectal cancer cell lines were grown on plastic surfaces or mid-range infrared transparent windows. Medium in established cultures was replaced with paraffin mineral oil, or Fluorolube, for up to 2 h, and viability assessed by supravital staining. Drug handling characteristics were also assessed. Imaging of preparations was attempted by reflectance and transmission using a Varian FT-IR microscope. Cells covered by mineral oil remained viable for 2 h, with recovery into normal medium possible. MTT ((3-(4,5-dimethylthlazol-2-yl)-2,5-diphenyl tetrazolium) conversion to crystalline formazan and differential patterns of drug uptake were maintained. The combination of a calcium fluoride substrate, Fluorolube oil, and transmission optics proved best for spectroscopy. Spectral features were used to obtain images of live cells. The viability of cells overlaid with IR transparent oils was assessed as part of a technique to optimise conditions for FT-IR imaging. Images of untreated cells were obtained using both reflectance and transmission. This represents an effective means of imaging live cells by IR spectroscopy, and also means that imaging is not necessarily a terminal event. It also increases options for producing images based on real-time biochemistry in a range of in vitro experimental and 'optical biopsy' contexts.
Bosdou, J K; Venetis, C A; Dafopoulos, K; Zepiridis, L; Chatzimeletiou, K; Anifandis, G; Mitsoli, A; Makedos, A; Messinis, I E; Tarlatzis, B C; Kolibianakis, E M
2016-05-01
Does pretreatment with transdermal testosterone increase the number of cumulus-oocyte complexes (COCs) retrieved by more than 1.5 in poor responders undergoing intracytoplasmic sperm injection (ICSI), using recombinant follicle stimulating hormone (FSH) and gonadotrophin releasing hormone agonists (GnRHa)? Testosterone pretreatment failed to increase the number of COCs by more than 1.5 as compared with no pretreatment in poor responders undergoing ICSI (difference between medians: 0.0, 95% CI: -1.0 to +1.0). Androgens are thought to play an important role in early follicular development by enhancing ovarian sensitivity to FSH. In a recent meta-analysis, testosterone pretreatment resulted in an increase of 1.5 COCs as compared with no pretreatment. However, this effect was based on the analysis of only two randomized controlled trials (RCTs) including 163 patients. Evidently, there is a need for additional RCTs that will allow firmer conclusions to be drawn. The present RCT was designed to detect a difference of 1.5 COCs (sample size required = 48 patients). From 02/2014 until 04/2015, 50 poor responders fulfilling the Bologna criteria have been randomized (using a randomization list) to either testosterone pretreatment for 21 days ( ITALIC! n = 26) or no pretreatment ( ITALIC! n = 24). All patients underwent a long follicular GnRHa protocol. Recombinant FSH stimulation was started on Day 22 following GnRHa initiation. In the testosterone pretreatment group, a daily dose of 10 mg of testosterone gel was applied transdermally for 21 days starting from GnRHa initiation. Results are expressed as median (interquartile range). No differences in baseline characteristics were observed between the two groups compared. Testosterone levels [median (interquartile range)] were significantly higher in the testosterone pretreatment on the day of initiation of FSH stimulation [114 (99.5) ng/dl versus 20 (20) ng/dl, respectively, ITALIC! P < 0.001]. Duration of FSH stimulation [median (interquartile range)] was similar between the groups compared [12.5 (3.0) days versus 12 (3.0) days, respectively, ITALIC! P = 0.52]. The number of COCs retrieved [median (interquartile range)] was not different between the testosterone pretreatment and the no pretreatment groups [3.5 (4.0) versus 3.0 (3.0), 95% CI for the median: 2.0-5.0 versus 2.7-4.3, respectively; difference between medians: 0.0, 95% CI: +1.0 to -1.0). Similarly no differences were observed regarding fertilization rates [median (interquartile range)] [66.7% (32.5) versus 66.7% (42.9), respectively, ITALIC! P = 0.97] and live birth rates per randomized patient (7.7% versus 8.3%, respectively, rate difference: -0.6%, 95% CI: -19.0 to +16.9). The study was not powered to detect differences less than 1.5 COCs, although it is doubtful whether these differences would be clinically relevant. Moreover, due to sample size restrictions, no conclusions can be drawn regarding the probability of live birth. The results of this randomized clinical trial, suggesting that pretreatment with 10 mg of transdermal testosterone for 21 days does not improve ovarian response by more than 1.5 oocytes, could be used to more accurately consult patients with poor ovarian response. However, an improvement in IVF outcome using a higher dose of testosterone or a longer pretreatment period cannot be excluded. The study was partially funded by a Scholarship from the Academy of Athens. C.A.V. reports personal fees and non-financial support from Merck, Sharp and Dome, personal fees and non-financial support from Merck Serono, personal fees and non-financial support from IPSEN Hellas S.A., outside the submitted work. B.C.T. reports grants from Merck Serono, grants from Merck Sharp & Dohme, personal fees from Merck Serono, personal fees from Merck Sharp & Dohme, personal fees from IBSA & Ferring, outside the submitted work. NCT01961336. 10 October 2013. 02/2014. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sailer, Heiko; Shinoda, Kei; Blatsios, Georgios; Kohler, Konrad; Bondzio, Lars; Zrenner, Eberhart; Gekeler, Florian
2007-08-01
Retinal implants are intended to replace photoreceptors in patients suffering from degenerative retinal diseases such as retinitis pigmentosa. Data show that photodiodes in subretinal implants are not powerful enough to stimulate overlying retinal tissue by simply transforming light energy into electrical energy. Therefore, infrared (IR) irradiation has been envisioned to supply additional energy. While epiretinal implants mostly use induction coils for wireless energy transfer, IR irradiation seems to be an additional option. This study investigated the feasibility of an IR energy supply for an active subretinal implant by assessing thermal effects of IR irradiation onto the rabbit retina. Polyimide foil strips carrying an optical sensor as well as a thermal sensor were implanted into the subretinal space of the eyes of nine rabbits using a transchoroidal surgical approach. The area of the thermal sensor was irradiated by an IR laser (830 nm) focused on the device. The sensor provided simultaneous real-time measurements of absolute temperature and irradiation density, allowing direct correlation of the temperature increase to different intensities of IR irradiation. Possible IR-related damage to the retina was examined in histological sections. Temperature changes in living and dead animals were evaluated as a function of IR irradiation power of between 0.1 mW and 40 mW (0.03 mW/mm2-12.7 mW/mm2). We found an exponential relationship between IR irradiation power and temperature increase over the whole range (up to 12.7 mW/mm2) in the living animal. The maximum temperature increase caused by IR irradiation of 40 mW (12.7 mW/mm2) was 4.5 degrees C. The ratio of temperature increase to IR irradiation density postmortem (i.e., without ocular blood flow) was linear over the whole range, with 1.15 degrees C per 1 mW/mm2. Thus, the cooling effect of ocular blood flow varied depending on IR irradiance density. In histological sections, no IR-induced damage to the retina was detected. A temperature increase of 3.2 degrees C in the living rabbit eye is to be expected when powering a subretinal implant with 15 mW (4.8 mW/mm2) IR power, the wattage used in an external power supply for an active implant with 1,500 electrodes. This appears to be a tolerable increase for ocular tissue.
Exploring the Full Range of Properties of Quasar Spectral Distributions
NASA Technical Reports Server (NTRS)
Wilkes, B.
1998-01-01
The aim of this work is to support our ISO, far-infrared (IR) observing program of quasars and active galaxies. We have obtained, as far as possible, complete spectral energy distributions (radio-X-ray) of the ISO sample in order to fully delineate the continuum shapes and to allow detailed modelling of that continuum. This includes: ground-based optical, near-IR and mm data, the spectral ranges closest to the ISO data, within 1-2 years of the ISO observations themselves. ISO was launched in Nov 1995 and is currently observing routinely. It has an estimated lifetime is 2 years. All near-IR and optical imaging and spectroscopy are now in hand and in the process of being reduced, mm data collection and proposal writing continues.
Pigments which reflect infrared radiation from fire
Berdahl, P.H.
1998-09-22
Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer ({micro}m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 {micro}m or, for cool smoky fires, about 2 {micro}m to about 16 {micro}m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 {micro}m to about 2 {micro}m and thin leafing aluminum flake pigments. 4 figs.
Concepts for compact mid-IR spectroscopy in photochemistry
NASA Astrophysics Data System (ADS)
Cu-Nguyen, Phuong-Ha; Wang, Ziyu; Zappe, Hans
2016-11-01
Mid-infrared (IR) spectroscopy, typically 3 to 5 µm, is often the technology of choice to monitor the interaction between and concentration of molecules during photochemical reactions. However, classical mid-IR spectrometers are bulky, complex and expensive, making them unsuitable for use in the miniaturized microreactors increasingly being employed for chemical synthesis. We present here the concept for an ultra-miniaturized mid-IR spectrometer directly integrated onto a chemical microreactor to monitor the chemical reaction. The spectrometer is based on micro-machined Fabry-Perot resonator filters realized using pairs of Bragg mirrors to achieve a high spectral resolution. The fabrication of the optical filters is outlined and the measurement of transmittance spectra in the mid-IR range show a good agreement with theory and are thus promising candidates for a fully integrated system.
NASA Astrophysics Data System (ADS)
Suzuki, Toyoaki; Wada, Takehiko; Hirose, Kazuyuki; Makitsubo, Hironobu; Kaneda, Hidehiro
2012-08-01
We have evaluated the optical and electrical properties of a far-infrared (IR) transparent electrode for extrinsic germanium (Ge) photoconductors at 4 K, which was fabricated by molecular beam epitaxy (MBE). As a far-IR transparent electrode, an aluminum (Al)-doped Ge layer is formed at well-optimized doping concentration and layer thickness in terms of the three requirements: high far-IR transmittance, low-resistivity, and excellent ohmic contact. The Al-doped Ge layer has the far-IR transmittance of >95% within the wavelength range of 40-200 μm, while low-resistivity ( ˜5 Ω cm) and ohmic contact are ensured at 4 K. We demonstrate the applicability of the MBE technology in fabricating the far-IR transparent electrode satisfying the above requirements.
NASA Astrophysics Data System (ADS)
Vollmer, M.
2013-11-01
'Infrared' is a very wide field in physics and the natural sciences which has evolved enormously in recent decades. It all started in 1800 with Friedrich Wilhelm Herschel's discovery of infrared (IR) radiation within the spectrum of the Sun. Thereafter a few important milestones towards widespread use of IR were the quantitative description of the laws of blackbody radiation by Max Planck in 1900; the application of quantum mechanics to understand the rotational-vibrational spectra of molecules starting in the first half of the 20th century; and the revolution in source and detector technologies due to micro-technological breakthroughs towards the end of the 20th century. This has led to much high-quality and sophisticated equipment in terms of detectors, sources and instruments in the IR spectral range, with a multitude of different applications in science and technology. This special issue tries to focus on a few aspects of the astonishing variety of different disciplines, techniques and applications concerning the general topic of infrared radiation. Part of the content is based upon an interdisciplinary international conference on the topic held in 2012 in Bad Honnef, Germany. It is hoped that the information provided here may be useful for teaching the general topic of electromagnetic radiation in the IR spectral range in advanced university courses for postgraduate students. In the most general terms, the infrared spectral range is defined to extend from wavelengths of 780 nm (upper range of the VIS spectral range) up to wavelengths of 1 mm (lower end of the microwave range). Various definitions of near, middle and far infrared or thermal infrared, and lately terahertz frequencies, are used, which all fall in this range. These special definitions often depend on the scientific field of research. Unfortunately, many of these fields seem to have developed independently from neighbouring disciplines, although they deal with very similar topics in respect of the underlying physics. There are now at least six different disciplines that deal with infrared radiation in one form or another, and in one or several different spectral portions of the whole IR range. These are spectroscopy, astronomy, thermal imaging, detector and source development and metrology, as well the field of optical data transmission. Scientists working in these fields range from chemists and astronomers through to physicists and even photographers. This issue presents examples from some of these fields. All the papers—though some of them deal with fundamental or applied research—include interesting elements that make them directly applicable to university-level teaching at the graduate or postgraduate level. Source (e.g. quantum cascade lasers) and detector development (e.g. multispectral sensors), as well as metrology issues and optical data transmission, are omitted since they belong to fundamental research journals. Using a more-or-less arbitrary order according to wavelength range, the issue starts with a paper on the physics of near-infrared photography using consumer product cameras in the spectral range from 800 nm to 1.1 µm [1]. It is followed by a series of three papers dealing with IR imaging in spectral ranges from 3 to 14 µm [2-4]. One of them deals with laboratory courses that may help to characterize the IR camera response [2], the second discusses potential applications for nondestructive testing techniques [3] and the third gives an example of how IR thermal imaging may be used to understand cloud cover of the Earth [4], which is the prerequisite for successful climate modelling. The next two papers cover the vast field of IR spectroscopy [5, 6]. The first of these deals with Fourier transform infrared spectroscopy in the spectral range from 2.5 to 25 µm, studying e.g. ro-vibrational excitations in gases or optical phonon interactions within solids [5]. The second deals mostly with the spectroscopy of liquids such as biofuels and special techniques such as attenuated total reflectance [6]. The two final papers deal with what seem to be wholly different scientific fields [7, 8]. One paper describes SOFIA, an aeroplane-based astronomical observatory covering the whole IR range [7], while the other represents a small review of the quite new topic of terahertz physics at the upper end of the IR spectral range, from around 30 µm to 3 mm wavelength, and its many applications in science and industry [8]. Although artificially separated, all these fields use similar kinds of detectors, similar kinds of IR sources and similar technologies, while the instruments use the same physical principles. We are convinced that the field of infrared physics will develop over the next decade in the same dynamic way as during the last, and this special issue may serve as starting point for regular submissions on the topic. At any rate, it shines a light on this fascinating and many-faceted subject, which started more than 200 years ago. References [1] Mangold K, Shaw J A and Vollmer M 2013 The physics of near-infrared photography Eur. J. Phys. 34 S51-71 [2] Vollmer M and Möllmann K-P 2013 Characterization of IR cameras in student labs Eur. J. Phys. 34 S73-90 [3] Ibarra-Castanedo C, Tarpani J R and Maldague X P V 2013 Nondestructive testing with thermography Eur. J. Phys. 34 S91-109 [4] Shaw J A and Nugent P W 2013 Physics principles in radiometric infrared imaging of clouds in the atmosphere Eur. J. Phys. 34 S111-21 [5] Möllmann K-P and Vollmer M 2013 Fourier transform infrared spectroscopy in physics laboratory courses Eur. J. Phys. 34 S123-37 [6] Heise H M, Fritzsche J, Tkatsch H, Waag F, Karch K, Henze K, Delbeck S and Budde J 2013 Recent advances in mid- and near-infrared spectroscopy with applications for research and teaching, focusing on petrochemistry and biotechnology relevant products Eur. J. Phys. 34 S139-59 [7] Krabbe A, Mehlert D, Röser H-P and Scorza C 2013 SOFIA, an airborne observatory for infrared astronomy Eur. J. Phys. 34 S161-77 [8] Zouaghi W, Thomson M D, Rabia K, Hahn R, Blank V and Roskos H G 2013 Broadband terahertz spectroscopy: principles, fundamental research and potential for industrial applications Eur. J. Phys. 34 S179-99
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fan, Lisha; Jacobs, Christopher B.; Rouleau, Christopher M.
In this paper, we demonstrate the reproducible epitaxial growth of 100 nm thick Ir(001) films on a heteroepitaxial stack consisting of 5 nm Ir and 100 nm yttria-stabilized zirconia (YSZ) grown on Si(001) substrates. It is shown that a 5 nm thick Ir layer grown by pulsed laser deposition in the same chamber as the YSZ film without breaking the vacuum is the key to stabilizing Ir(001) epitaxial growth. Growth of the Ir seed layer with pure (001) orientation occurs only in a narrow growth temperature window from 550 to 750 °C, and the fraction of Ir(111) increases at substratemore » temperatures outside of this window. The Ir seed layer prevents exposure of the YSZ film to air during sample transfer and enables highly reproducible Ir(001) heteroepitaxy on YSZ buffered Si(001). In contrast, if Ir is grown directly on a bare YSZ layer that was exposed to ambient conditions, the films are prone to change orientation to (111). These results reveal that preserving the chemical and structural purity of the YSZ surface is imperative for achieving Ir(001) epitaxy. The narrow range of the mosaic spread values from eight experiments demonstrates the high yield and high reproducibility of Ir(001) heteroepitaxy by this approach. Lastly, the improved Ir(001) epitaxial growth method is of great significance for integrating a variety of technologically important materials such as diamond, graphene, and functional oxides on a Si platform.« less
Fan, Lisha; Jacobs, Christopher B.; Rouleau, Christopher M.; ...
2016-11-18
In this paper, we demonstrate the reproducible epitaxial growth of 100 nm thick Ir(001) films on a heteroepitaxial stack consisting of 5 nm Ir and 100 nm yttria-stabilized zirconia (YSZ) grown on Si(001) substrates. It is shown that a 5 nm thick Ir layer grown by pulsed laser deposition in the same chamber as the YSZ film without breaking the vacuum is the key to stabilizing Ir(001) epitaxial growth. Growth of the Ir seed layer with pure (001) orientation occurs only in a narrow growth temperature window from 550 to 750 °C, and the fraction of Ir(111) increases at substratemore » temperatures outside of this window. The Ir seed layer prevents exposure of the YSZ film to air during sample transfer and enables highly reproducible Ir(001) heteroepitaxy on YSZ buffered Si(001). In contrast, if Ir is grown directly on a bare YSZ layer that was exposed to ambient conditions, the films are prone to change orientation to (111). These results reveal that preserving the chemical and structural purity of the YSZ surface is imperative for achieving Ir(001) epitaxy. The narrow range of the mosaic spread values from eight experiments demonstrates the high yield and high reproducibility of Ir(001) heteroepitaxy by this approach. Lastly, the improved Ir(001) epitaxial growth method is of great significance for integrating a variety of technologically important materials such as diamond, graphene, and functional oxides on a Si platform.« less
2009-06-01
additionally be utilized to cover a wider spectral range. In recent years, the long-wave IR ( LWIR : 8–12 m) region of the electromagnetic spectrum has been... LWIR region, and they can be sensed by their apparent temper- atures and spectral signatures in the LWIR . Currently, there are three main material...technologies for photonic IR photodetectors in the LWIR region. The HgCdTe (MCT) detector is the current state of the art due to its high responsivity
2008-06-01
IR )/laser designator (LD)/laser range finder (LRF) sensor. The Class I UAS consists of a Class I UAV, a cen- tralized controller and a minimal set...utility of a backpackable, affordable, easy-to- operate and responsive reconnais- sance and surveillance system through experimentation. • Use EO/ IR ...ARMY AL&T 33APRIL - JUNE 2008 • “The IR sensor pinpointed the enemy even after the sun went down. We could have really used this in Iraq.” • “The UAV
Synthesis of oxindole from acetanilide via Ir(iii)-catalyzed C-H carbenoid functionalization.
Patel, Pitambar; Borah, Gongutri
2016-12-22
Herein we disclose the first report on the synthesis of oxindole derivatives from acetanilide via Ir(iii)-catalyzed intermolecular C-H functionalization with diazotized Meldrum's acid. A broad range of substituted anilides were found to react smoothly under the Ir(iii)-catalytic system to afford the corresponding N-protected oxindoles. The N-protecting groups, such as Ac, Bz or Piv, can be easily removed to furnish the oxindole. Various synthetic applications of the synthesized oxindole were also demonstrated.
Influence of electron doping on the ground state of (Sr 1-xLa x) 2IrO 4
Chen, Xiang; Hogan, Tom; Walkup, D.; ...
2015-08-17
The evolution of the electronic properties of electron-doped (Sr 1-xLa x) 2IrO 4 is experimentally explored as the doping limit of La is approached. As electrons are introduced, the electronic ground state transitions from a spin-orbit Mott phase into an electronically phase separated state, where long-range magnetic order vanishes beyond x = 0:02 and charge transport remains percolative up to the limit of La substitution (x =0:06). In particular, the electronic ground state remains inhomogeneous even beyond the collapse of the parent state's long-range antiferromagnetic order, while persistent short-range magnetism survives up to the highest La-substitution levels. Furthermore, as electronsmore » are doped into Sr 2IrO 4, we observe the appearance of a low temperature magnetic glass-like state intermediate to the complete suppression of antiferromagnetic order. Universalities and di erences in the electron-doped phase diagrams of single layer and bilayer Ruddlesden-Popper strontium iridates are discussed.« less
Larochelle, Marc R; Bernson, Dana; Land, Thomas; Stopka, Thomas J; Wang, Na; Xuan, Ziming; Bagley, Sarah M; Liebschutz, Jane M; Walley, Alexander Y
2018-06-19
Opioid overdose survivors have an increased risk for death. Whether use of medications for opioid use disorder (MOUD) after overdose is associated with mortality is not known. To identify MOUD use after opioid overdose and its association with all-cause and opioid-related mortality. Retrospective cohort study. 7 individually linked data sets from Massachusetts government agencies. 17 568 Massachusetts adults without cancer who survived an opioid overdose between 2012 and 2014. Three types of MOUD were examined: methadone maintenance treatment (MMT), buprenorphine, and naltrexone. Exposure to MOUD was identified at monthly intervals, and persons were considered exposed through the month after last receipt. A multivariable Cox proportional hazards model was used to examine MOUD as a monthly time-varying exposure variable to predict time to all-cause and opioid-related mortality. In the 12 months after a nonfatal overdose, 2040 persons (11%) enrolled in MMT for a median of 5 months (interquartile range, 2 to 9 months), 3022 persons (17%) received buprenorphine for a median of 4 months (interquartile range, 2 to 8 months), and 1099 persons (6%) received naltrexone for a median of 1 month (interquartile range, 1 to 2 months). Among the entire cohort, all-cause mortality was 4.7 deaths (95% CI, 4.4 to 5.0 deaths) per 100 person-years and opioid-related mortality was 2.1 deaths (CI, 1.9 to 2.4 deaths) per 100 person-years. Compared with no MOUD, MMT was associated with decreased all-cause mortality (adjusted hazard ratio [AHR], 0.47 [CI, 0.32 to 0.71]) and opioid-related mortality (AHR, 0.41 [CI, 0.24 to 0.70]). Buprenorphine was associated with decreased all-cause mortality (AHR, 0.63 [CI, 0.46 to 0.87]) and opioid-related mortality (AHR, 0.62 [CI, 0.41 to 0.92]). No associations between naltrexone and all-cause mortality (AHR, 1.44 [CI, 0.84 to 2.46]) or opioid-related mortality (AHR, 1.42 [CI, 0.73 to 2.79]) were identified. Few events among naltrexone recipients preclude confident conclusions. A minority of opioid overdose survivors received MOUD. Buprenorphine and MMT were associated with reduced all-cause and opioid-related mortality. National Center for Advancing Translational Sciences of the National Institutes of Health.
Beshish, Asaad G; Baginski, Mathew R; Johnson, Thomas J; Deatrick, Barry K; Barbaro, Ryan P; Owens, Gabe E
2018-04-13
The purpose of this study is to describe the functional status of survivors from extracorporeal cardiopulmonary resuscitation instituted during in-hospital cardiac arrest using the Functional Status Scale. We aimed to determine risk factors leading to the development of new morbidity and unfavorable functional outcomes. This was a single-center retrospective chart review abstracting patient characteristics/demographic data, duration of cardiopulmonary resuscitation, duration of extracorporeal membrane oxygenation support, as well as maximum lactate levels within 2 hours before and after extracorporeal cardiopulmonary resuscitation. Cardiac arrest was defined as the administration of chest compressions for a nonperfusing cardiac rhythm. Extracorporeal cardiopulmonary resuscitation was defined by instituting extracorporeal membrane oxygenation during active chest compressions. Functional Status Scale scores were calculated at admission and on hospital discharge for patients who survived. Patients admitted in the pediatric cardiac ICU at C.S. Mott Children's Hospital from January 1, 2005, to December 31, 2015. Children less than 18 years who underwent extracorporeal cardiopulmonary resuscitation. Not applicable. Of 608 extracorporeal membrane oxygenation events during the study period, 80 were extracorporeal cardiopulmonary resuscitation (14%). There were 40 female patients (50%). Median age was 40 days (interquartile range, 9-342 d). Survival to hospital discharge was 48% (38/80). Median Functional Status Scale score at admission was 6 (interquartile range, 6-6) and at hospital discharge 9 (interquartile range, 8-11). Out of 38 survivors, 19 (50%) had a change of Functional Status Scale score greater than or equal to 3, that is consistent with new morbidity, and 26 (68%) had favorable functional outcomes with a change in Functional Status Scale score of less than 5. This is the first extracorporeal cardiopulmonary resuscitation report to examine changes in Functional Status Scale from admission (baseline) to discharge as a measure of overall functional outcome. Half of surviving patients (19/38) had new morbidity, while 68% (26/38) had favorable outcomes. Lactate levels, duration of cardiopulmonary resuscitation, and duration of extracorporeal membrane oxygenation were not found to be risk factors for the development of new morbidity and poor functional outcomes. Functional Status Scale may be used as a metric to monitor improvement of extracorporeal cardiopulmonary resuscitation outcomes and help guide research initiatives to decrease morbidity in this patient population.
Geographic clustering of elevated blood heavy metal levels in pregnant women.
King, Katherine E; Darrah, Thomas H; Money, Eric; Meentemeyer, Ross; Maguire, Rachel L; Nye, Monica D; Michener, Lloyd; Murtha, Amy P; Jirtle, Randy; Murphy, Susan K; Mendez, Michelle A; Robarge, Wayne; Vengosh, Avner; Hoyo, Cathrine
2015-10-09
Cadmium (Cd), lead (Pb), mercury (Hg), and arsenic (As) exposure is ubiquitous and has been associated with higher risk of growth restriction and cardiometabolic and neurodevelopmental disorders. However, cost-efficient strategies to identify at-risk populations and potential sources of exposure to inform mitigation efforts are limited. The objective of this study was to describe the spatial distribution and identify factors associated with Cd, Pb, Hg, and As concentrations in peripheral blood of pregnant women. Heavy metals were measured in whole peripheral blood of 310 pregnant women obtained at gestational age ~12 weeks. Prenatal residential addresses were geocoded and geospatial analysis (Getis-Ord Gi* statistics) was used to determine if elevated blood concentrations were geographically clustered. Logistic regression models were used to identify factors associated with elevated blood metal levels and cluster membership. Geospatial clusters for Cd and Pb were identified with high confidence (p-value for Gi* statistic <0.01). The Cd and Pb clusters comprised 10.5 and 9.2 % of Durham County residents, respectively. Medians and interquartile ranges of blood concentrations (μg/dL) for all participants were Cd 0.02 (0.01-0.04), Hg 0.03 (0.01-0.07), Pb 0.34 (0.16-0.83), and As 0.04 (0.04-0.05). In the Cd cluster, medians and interquartile ranges of blood concentrations (μg/dL) were Cd 0.06 (0.02-0.16), Hg 0.02 (0.00-0.05), Pb 0.54 (0.23-1.23), and As 0.05 (0.04-0.05). In the Pb cluster, medians and interquartile ranges of blood concentrations (μg/dL) were Cd 0.03 (0.02-0.15), Hg 0.01 (0.01-0.05), Pb 0.39 (0.24-0.74), and As 0.04 (0.04-0.05). Co-exposure with Pb and Cd was also clustered, the p-values for the Gi* statistic for Pb and Cd was <0.01. Cluster membership was associated with lower education levels and higher pre-pregnancy BMI. Our data support that elevated blood concentrations of Cd and Pb are spatially clustered in this urban environment compared to the surrounding areas. Spatial analysis of metals concentrations in peripheral blood or urine obtained routinely during prenatal care can be useful in surveillance of heavy metal exposure.
Persaud, Deborah; Patel, Kunjal; Karalius, Brad; Rainwater-Lovett, Kaitlin; Ziemniak, Carrie; Ellis, Angela; Chen, Ya Hui; Richman, Douglas; Siberry, George K.; Van Dyke, Russell B.; Burchett, Sandra; Seage, George R.; Luzuriaga, Katherine
2014-01-01
Importance Combination antiretroviral therapy (cART) initiated within several weeks of HIV infection in adults limits proviral reservoirs that preclude HIV cure. Biomarkers of restricted proviral reservoirs may aid in the monitoring of HIV remission or cure. Objectives To quantify peripheral blood proviral reservoir size in perinatally HIV-infected adolescents and to identify correlates of limited proviral reservoirs. Design, Setting, and Participants A cross-sectional study including 144 perinatally HIV-infected (PHIV+) youth (median age: 14.3 years), enrolled in the US-based Pediatric HIV/AIDS Cohort Study, on durable (median: 10.2 years) cART, stratified by age at virologic control. Main Outcome and Measures The primary endpoint was peripheral blood mononuclear cell (PBMC) proviral load following virologic control at different ages. Correlations between proviral load and markers of active HIV production (HIV-specific antibodies, 2-long terminal repeat (2-LTR) circles), and markers of immune activation and inflammation were also assessed. Results Proviral reservoir size was markedly reduced in the PHIV+ youth who achieved virologic control by age 1 year (4.2 [interquartile range, 2.6-8 6] copies per 1 million PBMCs) compared to those who achieved virologic control between 1-5 years of age (19.4 [interquartile range, 5.5-99.8] copies per 1 million PBMCs) or after age 5 years (−(70.7 [interquartile range, 23.2-209.4] copies per 1 million PBMCs; P < .00l). A proviral burden <10 copies/million PBMCs was measured in 11 (79%), 20 (40%), and 13 (18%) participants with virologic control at ages <1 year, 1-5 years, and >5 years, respectively (p<0.001). Lower proviral load was associated with undetectable 2-LTR circles (p<0.001) and HIV negative or indeterminate serostatus (p<0.001), but not with concentrations of soluble immune activation markers CD14 and CD163. Conclusions and Relevance Early effective cART along with prolonged virologic suppression after perinatal HIV infection leads to negligible peripheral blood proviral reservoirs in adolescence and is associated with negative or indeterminate HIV serostatus. These findings highlight the long-term effect of early effective control of HIV replication on biomarkers of HIV persistence in perinatal infection and the utility of HIV serostatus as a biomarker for small proviral reservoir size, though not necessarily of cure. PMID:25286283
Buonerba, Carlo; Sonpavde, Guru; Vitrone, Francesca; Bosso, Davide; Puglia, Livio; Izzo, Michela; Iaccarino, Simona; Scafuri, Luca; Muratore, Margherita; Foschini, Francesca; Mucci, Brigitta; Tortora, Vincenzo; Pagliuca, Martina; Ribera, Dario; Riccio, Vittorio; Morra, Rocco; Mosca, Mirta; Cesarano, Nicola; Di Costanzo, Ileana; De Placido, Sabino; Di Lorenzo, Giuseppe
2017-01-01
Background: Cabazitaxel is a second-generation taxane that is approved for use with concomitant low dose daily prednisone in metastatic castration resistant prostate cancer (mCRPC) after docetaxel failure. Since the role of daily corticosteroids in improving cabazitaxel efficacy or ameliorating its safety profile has not been adequately investigated so far, we compared outcomes of patients receiving cabazitaxel with or without daily corticosteroids in a retrospective single-Institution cohort of mCRPC patients. Patients and methods: Medical records of deceased patients with documented mCRPC treated with cabazitaxel following prior docetaxel between January, 2011 and January, 2017 were reviewed at the single participating center. Patients who were receiving daily doses of systemic corticosteroids other than low dose daily prednisone or prednisolone (<= 10 mg a day) were excluded. The primary end point of this analysis was overall survival (OS). Secondary end-points were exposure to cabazitaxel as well as incidence of grade 3-4 adverse events. Univariable and multivariable Cox proportional hazards regression was used to evaluate prednisone use and other variables as potentially prognostic for overall survival. Results: Overall, among 91 patients, 57 patients received cabazitaxel concurrently with low dose prednisone and 34 patients did not receive concurrent prednisone. The median overall survival of the population was 9.8 months (interquartile range, 9 to 14). Patients receiving prednisone had an overall survival of 9 months (interquartile range, 8 to 12) vs.14 months (interquartile range, 9.4 to 16.7) for patients not treated with prednisone. Approximately 45% of patients had a >30% PSA decline at 12 weeks. Prednisone use was not significantly prognostic for overall survival or PSA decline ≥30% rates on regression analyses. Importantly, a >30% PSA decline at 12, but not at 3, 6, 9 weeks, was prognostic for improved survival at multivariate analysis Conclusions: The data presented here support the hypothesis that omitting daily corticosteroids in cabazitaxel-treated patients has no negative impact on either survival or safety profile. In the large prospective trial CABACARE, cabazitaxel-treated patients will be randomized to receive or not receive daily prednisone. The CABACARE (EudraCT n. 2016-003646-81) study is currently ongoing at University Federico II of Naples and at other multiple participating centers in Italy.
Buonerba, Carlo; Sonpavde, Guru; Vitrone, Francesca; Bosso, Davide; Puglia, Livio; Izzo, Michela; Iaccarino, Simona; Scafuri, Luca; Muratore, Margherita; Foschini, Francesca; Mucci, Brigitta; Tortora, Vincenzo; Pagliuca, Martina; Ribera, Dario; Riccio, Vittorio; Morra, Rocco; Mosca, Mirta; Cesarano, Nicola; Di Costanzo, Ileana; De Placido, Sabino; Di Lorenzo, Giuseppe
2017-01-01
Background: Cabazitaxel is a second-generation taxane that is approved for use with concomitant low dose daily prednisone in metastatic castration resistant prostate cancer (mCRPC) after docetaxel failure. Since the role of daily corticosteroids in improving cabazitaxel efficacy or ameliorating its safety profile has not been adequately investigated so far, we compared outcomes of patients receiving cabazitaxel with or without daily corticosteroids in a retrospective single-Institution cohort of mCRPC patients. Patients and methods: Medical records of deceased patients with documented mCRPC treated with cabazitaxel following prior docetaxel between January, 2011 and January, 2017 were reviewed at the single participating center. Patients who were receiving daily doses of systemic corticosteroids other than low dose daily prednisone or prednisolone (<= 10 mg a day) were excluded. The primary end point of this analysis was overall survival (OS). Secondary end-points were exposure to cabazitaxel as well as incidence of grade 3-4 adverse events. Univariable and multivariable Cox proportional hazards regression was used to evaluate prednisone use and other variables as potentially prognostic for overall survival. Results: Overall, among 91 patients, 57 patients received cabazitaxel concurrently with low dose prednisone and 34 patients did not receive concurrent prednisone. The median overall survival of the population was 9.8 months (interquartile range, 9 to 14). Patients receiving prednisone had an overall survival of 9 months (interquartile range, 8 to 12) vs.14 months (interquartile range, 9.4 to 16.7) for patients not treated with prednisone. Approximately 45% of patients had a >30% PSA decline at 12 weeks. Prednisone use was not significantly prognostic for overall survival or PSA decline ≥30% rates on regression analyses. Importantly, a >30% PSA decline at 12, but not at 3, 6, 9 weeks, was prognostic for improved survival at multivariate analysis Conclusions: The data presented here support the hypothesis that omitting daily corticosteroids in cabazitaxel-treated patients has no negative impact on either survival or safety profile. In the large prospective trial CABACARE, cabazitaxel-treated patients will be randomized to receive or not receive daily prednisone. The CABACARE (EudraCT n. 2016-003646-81) study is currently ongoing at University Federico II of Naples and at other multiple participating centers in Italy. PMID:28928853
Yorifuji, Takashi; Suzuki, Etsuji; Kashima, Saori
2014-08-13
Epidemiological studies have shown adverse effects of short-term exposure to air pollution on respiratory disease outcomes; however, few studies examined this association on an hourly time scale. We evaluated the associations between hourly changes in air pollution and the risk of respiratory disease in the elderly, using the time of the emergency call as the disease onset for each case. We used a time-stratified case-crossover design. Study participants were 6,925 residents of the city of Okayama, Japan, aged 65 or above who were taken to hospital emergency rooms between January 2006 and December 2010 for onset of respiratory disease. We calculated city-representative hourly average concentrations of air pollutants from several monitoring stations. By using conditional logistic regression models, we estimated odds ratios per interquartile-range increase in each pollutant by exposure period prior to emergency call, adjusting for hourly ambient temperature, hourly relative humidity, and weekly numbers of reported influenza cases aged ≥60. Suspended particulate matter (SPM) exposure 24 to <72 hours prior to the onset and ozone exposure 48 to <96 hours prior to the onset were associated with the increased risk of respiratory disease. For example, following one interquartile-range increase, odds ratios were 1.05 (95% confidence interval: 1.01, 1.09) for SPM exposure 24 to <48 hours prior to the onset and 1.13 (95% confidence interval: 1.04, 1.23) for ozone exposure 72 to <96 hours prior to the onset. Sulfur dioxide (SO2) exposure 0 to <24 hours prior to onset was associated with the increased risk of pneumonia and influenza: odds ratio was 1.07 per one interquartile-range increase (95% confidence interval: 1.00, 1.14). Elevated risk for pneumonia and influenza of SO2 was observed at shorter lags (i.e., 8-18 hours) than the elevated risks for respiratory disease of SPM or ozone. Overall, the effect estimates for chronic obstructive pulmonary disease and allied conditions were equivocal. This study provides further evidence that hourly changes in air pollution exposure increase the risks of respiratory disease, and that SO2 may be related with more immediate onset of the disease than other pollutants.
Zittema, Debbie; van den Berg, Else; Meijer, Esther; Boertien, Wendy E; Muller Kobold, Anneke C; Franssen, Casper F M; de Jong, Paul E; Bakker, Stephan J L; Navis, Gerjan; Gansevoort, Ron T
2014-09-05
Plasma copeptin, a marker of arginine vasopressin, is elevated in patients with autosomal dominant polycystic kidney disease and predicts disease progression. It is unknown whether elevated copeptin levels result from decreased kidney clearance or as compensation for impaired concentrating capacity. Data from patients with autosomal dominant polycystic kidney disease and healthy kidney donors before and after donation were used, because after donation, overall GFR decreases with a functionally normal kidney. Data were obtained between October of 2008 and January of 2012 from healthy kidney donors who visited the institution for routine measurements predonation and postdonation and patients with autosomal dominant polycystic kidney disease who visited the institution for kidney function measurement. Plasma copeptin levels were measured using a sandwich immunoassay, GFR was measured as (125)I-iothalamate clearance, and urine concentrating capacity was measured as urine-to-plasma ratio of urea. In patients with autosomal dominant polycystic kidney disease, total kidney volume was measured with magnetic resonance imaging. Patients with autosomal dominant polycystic kidney disease (n=122, age=40 years, men=56%) had significantly higher copeptin levels (median=6.8 pmol/L; interquartile range=3.4-15.7 pmol/L) compared with donors (n=134, age=52 years, men=49%) both predonation and postdonation (median=3.8 pmol/L; interquartile range=2.8-6.3 pmol/L; P<0.001; median=4.4 pmol/L; interquartile range=3.6-6.1 pmol/L; P<0.001). In donors, copeptin levels did not change after donation, despite a significant fall in GFR (from 105 ± 17 to 66 ± 10; P<0.001). Copeptin and GFR were significantly associated in patients with autosomal dominant polycystic kidney disease (β=-0.45, P<0.001) but not in donors. In patients with autosomal dominant polycystic kidney disease, GFR and total kidney volume were both associated significantly with urine-to-plasma ratio of urea (β=0.84, P<0.001; β=-0.51, P<0.001, respectively). On the basis of the finding in donors that kidney clearance is not a main determinant of plasma copeptin levels, it was hypothesized that, in patients with autosomal dominant polycystic kidney disease, kidney damage and associated impaired urine concentration capacity determine copeptin levels. Copyright © 2014 by the American Society of Nephrology.
High-Temperature Oxidation Behavior of Iridium-Rhenium Alloys
NASA Technical Reports Server (NTRS)
Reed, Brian D.
1995-01-01
The life-limiting mechanism for radiation-cooled rockets made from iridium-coated rhenium (Ir/Re) is the diffusion of Re into the Ir layer and the subsequent oxidation of the resulting Ir-Re alloy from the inner surface. In a previous study, a life model for Ir/Re rockets was developed. It incorporated Ir-Re diffusion and oxidation data to predict chamber lifetimes as a function of temperature and oxygen partial pressure. Oxidation testing at 1540 deg C suggested that a 20-wt percent Re concentration at the inner wall surface should be established as the failure criterion. The present study was performed to better define Ir-oxidation behavior as a function of Re concentration and to supplement the data base for the life model. Samples ranging from pure Ir to Ir-40 wt percent Re (Ir-40Re) were tested at 1500 deg C, in two different oxygen environments. There were indications that the oxidation rate of the Ir-Re alloy increased significantly when it went from a single-phase solid solution to a two-phase mixture, as was suggested in previous work. However, because of testing anomalies in this study, there were not enough dependable oxidation data to definitively raise the Ir/Re rocket failure criterion from 20-wt percent Re to a Re concentration corresponding to entry into the two-phase region.
Revenue Potential for Inpatient IR Consultation Services: A Financial Model.
Misono, Alexander S; Mueller, Peter R; Hirsch, Joshua A; Sheridan, Robert M; Siddiqi, Assad U; Liu, Raymond W
2016-05-01
Interventional radiology (IR) has historically failed to fully capture the value of evaluation and management services in the inpatient setting. Understanding financial benefits of a formally incorporated billing discipline may yield meaningful insights for interventional practices. A revenue modeling tool was created deploying standard financial modeling techniques, including sensitivity and scenario analyses. Sensitivity analysis calculates revenue fluctuation related to dynamic adjustment of discrete variables. In scenario analysis, possible future scenarios as well as revenue potential of different-size clinical practices are modeled. Assuming a hypothetical inpatient IR consultation service with a daily patient census of 35 patients and two new consults per day, the model estimates annual charges of $2.3 million and collected revenue of $390,000. Revenues are most sensitive to provider billing documentation rates and patient volume. A range of realistic scenarios-from cautious to optimistic-results in a range of annual charges of $1.8 million to $2.7 million and a collected revenue range of $241,000 to $601,000. Even a small practice with a daily patient census of 5 and 0.20 new consults per day may expect annual charges of $320,000 and collected revenue of $55,000. A financial revenue modeling tool is a powerful adjunct in understanding economics of an inpatient IR consultation service. Sensitivity and scenario analyses demonstrate a wide range of revenue potential and uncover levers for financial optimization. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Gilliom, Robert J.; Helsel, Dennis R.
1986-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations, for determining the best performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.
Ghosh, Jo Kay C.; Wilhelm, Michelle; Su, Jason; Goldberg, Daniel; Cockburn, Myles; Jerrett, Michael; Ritz, Beate
2012-01-01
Few studies have examined associations of birth outcomes with toxic air pollutants (air toxics) in traffic exhaust. This study included 8,181 term low birth weight (LBW) children and 370,922 term normal-weight children born between January 1, 1995, and December 31, 2006, to women residing within 5 miles (8 km) of an air toxics monitoring station in Los Angeles County, California. Additionally, land-use-based regression (LUR)-modeled estimates of levels of nitric oxide, nitrogen dioxide, and nitrogen oxides were used to assess the influence of small-area variations in traffic pollution. The authors examined associations with term LBW (≥37 weeks’ completed gestation and birth weight <2,500 g) using logistic regression adjusted for maternal age, race/ethnicity, education, parity, infant gestational age, and gestational age squared. Odds of term LBW increased 2%–5% (95% confidence intervals ranged from 1.00 to 1.09) per interquartile-range increase in LUR-modeled estimates and monitoring-based air toxics exposure estimates in the entire pregnancy, the third trimester, and the last month of pregnancy. Models stratified by monitoring station (to investigate air toxics associations based solely on temporal variations) resulted in 2%–5% increased odds per interquartile-range increase in third-trimester benzene, toluene, ethyl benzene, and xylene exposures, with some confidence intervals containing the null value. This analysis highlights the importance of both spatial and temporal contributions to air pollution in epidemiologic birth outcome studies. PMID:22586068
Financial Ties Between Emergency Physicians and Industry: Insights From Open Payments Data.
Fleischman, William; Ross, Joseph S; Melnick, Edward R; Newman, David H; Venkatesh, Arjun K
2016-08-01
The Open Payments program requires reporting of payments by medical product companies to teaching hospitals and licensed physicians. We seek to describe nonresearch, nonroyalty payments made to emergency physicians in the United States. We performed a descriptive analysis of the most recent Open Payments data released to the public by the Centers for Medicare & Medicaid Services covering the 2014 calendar year. We calculated the median payment, the total pay per physician, the types of payments, and the drugs and devices associated with payments to emergency physicians. For context, we also calculated total pay per physician and the percentage of active physicians receiving payments for all specialties. There were 46,405 payments totaling $10,693,310 to 12,883 emergency physicians, representing 30% of active emergency physicians in 2013. The percentage of active physicians within a specialty who received a payment ranged from 14.6% in preventive medicine to 91% in orthopedic surgery. The median payment and median total pay to emergency physicians were $16 (interquartile range $12 to $68) and $44 (interquartile range $16 to $123), respectively. The majority of payments (83%) were less than $100. Food and beverage (86%) was the most frequent type of payment. The most common products associated with payments to emergency physicians were rivaroxaban, apixaban, ticagrelor, ceftaroline, canagliflozin, dabigatran, and alteplase. Nearly a third of emergency physicians received nonresearch, nonroyalty payments from industry in 2014. Most payments were of small monetary value and for activities related to the marketing of antithrombotic drugs. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1986-02-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensoredmore » observations, for determining the best performing parameter estimation method for any particular data det. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.« less
Estimation of distributional parameters for censored trace-level water-quality data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1984-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water-sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations,more » for determining the best-performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least-squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification. 6 figs., 6 tabs.« less
Daniels, Tracey; Goodacre, Lynne; Sutton, Chris; Pollard, Kim; Conway, Steven; Peckham, Daniel
2011-08-01
People with cystic fibrosis have a high treatment burden. While uncertainty remains about individual patient level of adherence to medication, treatment regimens are difficult to tailor, and interventions are difficult to evaluate. Self- and clinician-reported measures are routinely used despite criticism that they overestimate adherence. This study assessed agreement between rates of adherence to prescribed nebulizer treatments when measured by self-report, clinician report, and electronic monitoring suitable for long-term use. Seventy-eight adults with cystic fibrosis were questioned about their adherence to prescribed nebulizer treatments over the previous 3 months. Self-report was compared with clinician report and stored adherence data downloaded from the I-Neb nebulizer system. Adherence measures were expressed as a percentage of the prescribed regimen, bias was estimated by the paired difference in mean (95% CI) patient and clinician reported and actual adherence. Agreement between adherence measures was calculated using intraclass correlation coefficients (95% CI), and disagreements for individuals were displayed using Bland-Altman plots. Patient-identified prescriptions matched the medical record prescription. Median self-reported adherence was 80% (interquartile range, 60%-95%), whereas median adherence measured by nebulizer download was 36% (interquartile range, 5%-84.5%). Nine participants overmedicated and underreported adherence. Median clinician report ranged from 50% to 60%, depending on profession. Extensive discrepancies between self-report and clinician report compared with nebulizer download were identified for individuals. Self- and clinician-reporting of adherence does not provide accurate measurement of adherence when compared with electronic monitoring. Using inaccurate measures has implications for treatment burden, clinician prescribing practices, cost, and accuracy of trial data.
Ghosh, Jo Kay C; Wilhelm, Michelle; Su, Jason; Goldberg, Daniel; Cockburn, Myles; Jerrett, Michael; Ritz, Beate
2012-06-15
Few studies have examined associations of birth outcomes with toxic air pollutants (air toxics) in traffic exhaust. This study included 8,181 term low birth weight (LBW) children and 370,922 term normal-weight children born between January 1, 1995, and December 31, 2006, to women residing within 5 miles (8 km) of an air toxics monitoring station in Los Angeles County, California. Additionally, land-use-based regression (LUR)-modeled estimates of levels of nitric oxide, nitrogen dioxide, and nitrogen oxides were used to assess the influence of small-area variations in traffic pollution. The authors examined associations with term LBW (≥37 weeks' completed gestation and birth weight <2,500 g) using logistic regression adjusted for maternal age, race/ethnicity, education, parity, infant gestational age, and gestational age squared. Odds of term LBW increased 2%-5% (95% confidence intervals ranged from 1.00 to 1.09) per interquartile-range increase in LUR-modeled estimates and monitoring-based air toxics exposure estimates in the entire pregnancy, the third trimester, and the last month of pregnancy. Models stratified by monitoring station (to investigate air toxics associations based solely on temporal variations) resulted in 2%-5% increased odds per interquartile-range increase in third-trimester benzene, toluene, ethyl benzene, and xylene exposures, with some confidence intervals containing the null value. This analysis highlights the importance of both spatial and temporal contributions to air pollution in epidemiologic birth outcome studies.
Sympathetic nerve dysfunction is common in patients with chronic intestinal pseudo-obstruction.
Mattsson, Tomas; Roos, Robert; Sundkvist, Göran; Valind, Sven; Ohlsson, Bodil
2008-02-01
To clarify whether disturbances in the autonomic nervous system, reflected in abnormal cardiovascular reflexes, could explain symptoms of impaired heat regulation in patients with intestinal pseudo-obstruction. Chronic intestinal pseudo-obstruction is a clinical syndrome characterized by diffuse, unspecific gastrointestinal symptoms due to damage to the enteric nervous system or the smooth muscle cells. These patients often complain of excessive sweating or feeling cold, suggesting disturbances in the autonomic nervous system. Earlier studies have pointed to a coexistence of autonomic disturbances in the enteric and cardiovascular nervous system. Thirteen consecutive patients (age range 23 to 79, mean 44 y) fulfilling the criteria for chronic intestinal pseudo-obstruction were investigated. Six of them complained of sweating or a feeling of cold. Examination of autonomic reflexes included heart rate variation to deep-breathing (expiration/inspiration index), heart rate reaction to tilt (acceleration index, brake index), and vasoconstriction (VAC) due to indirect cooling by laser doppler (VAC-index; high index indicates impaired VAC). Test results in patients were compared with healthy individuals. Patients had significantly higher (more abnormal) median VAC-index compared with healthy controls [1.79 (interquartile ranges 1.89) vs. 0.08 (interquartile ranges 1.29); P=0.0007]. However, symptoms of impaired heat regulation were not related to the VAC-index. There were no differences in expiration/inspiration, acceleration index, or brake index between patients and controls. The patients with severe gastrointestinal dysmotility showed impaired sympathetic nerve function which, however, did not seem to be associated with symptoms of impaired heat regulation.
MicrOmega IR: a new infrared hyperspectral imaging microscope or in situ analysis
NASA Astrophysics Data System (ADS)
Vaitua, Leroi; Bibring, Jean-Pierre; Berthé, Michel
2017-11-01
MicrOmega IR is an ultra miniaturized Near Infrared hyperspectral microscope for in situ analysis of samples. It is designed to be implemented on board space planetary vehicles (lander and/or rovers). It acquires images of samples typically some 5 mm in width with a spatial sampling of 20 μm. On each pixel, MicrOmega acquires the spectrum in the spectral range 0.9 - 2.6 μm, with a possibility to extend the sensibility up to 4 μm. The spectrum will be measured in up to 300 contiguous spectral channels (600 in the extended range): given the diagnostic spectral features present in this domain, it provides the composition of each spatially resolved constituent. MicrOmega has thus the potential to identify: minerals, such as pyroxene and olivine, ferric oxides, hydrated phases such as phyllosilicates, sulfates and carbonates, ices and organics. The composition of the various phases within a given sample is a critical record of its formation and evolution. Coupled to the mapping information, it provides unique clues to describe the history of the parent body. In particular, the capability to identify hydrated grains and to characterize their adjacent phases has a huge potential in the search for potential bio-relics in Martian samples. This purely non destructive characterization enables further analyses (e.g. through mass spectrometry) to be performed, and/or to contribute to sample selection to return to Earth. MicrOmega IR is coupled to a visible microscope: MicrOmega VIS. Thus, the MicrOmega instrument is developed by an international consortium: IAS (Orsay, France), LESIA (Meudon, France), CBM (Orléans, France), University Of Bern (Bern, Switzerland), IKI (Moscow, Russia). This instrument (MicrOmega IR, MicrOmega VIS and the electronics) is selected for the ESA Exomars mission (launch scheduled for 2013). MicrOmega IR will be used in a reduced spectral range (0.9 - 2.6 μm), due to power, mass and thermal constraints: however, most minerals and other constituents have diagnostic spectral signature in this range. A full demonstrator model of ExoMars/MicrOmega IR has been assembled at IAS and we will present the design and the experimental results.
Anomaly Detection for Data Reduction in an Unattended Ground Sensor (UGS) Field
2014-09-01
information (shown with solid lines in the diagram). Typically, this would be a mobile ad - hoc network (MANET). The clusters are connected to other nodes...interquartile ranges MANET mobile ad - hoc network OSUS Open Standards for Unattended Sensors TOC tactical operations center UAVs unmanned aerial vehicles...19b. TELEPHONE NUMBER (Include area code ) 301-394-1221 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii Contents List of
Ibrahim, Moustafa I; Ramy, Ahmed R; Abdelhamid, Ahmed S; Ellaithy, Mohamed I; Omar, Amna; Harara, Rany M; Fathy, Hayam; Abolouz, Ashraf S
2017-03-01
To assess maternal serum amyloid A (SAA) levels among women with primary unexplained recurrent early pregnancy loss (REPL). A prospective study was conducted among women with missed spontaneous abortion in the first trimester at Ain Shams University Maternity Hospital, Cairo, Egypt, between January 21 and December 25, 2014. Women with at least two consecutive primary unexplained REPLs and no previous live births were enrolled. A control group was formed of women with no history of REPL who had at least one previous uneventful pregnancy with no adverse outcomes. Serum samples were collected to measure SAA levels. The main outcome was the association between SAA and primary unexplained REPL. Each group contained 96 participants. Median SAA level was significantly higher among women with REPL (50.0 μg/mL, interquartile range 26.0-69.0) than among women in the control group (11.6 μg/mL, interquartile range 6.2-15.5; P<0.001). The SAA level was an independent indicator of primary unexplained REPL, after adjusting for maternal age and gestational age (odds ratio 1.12, 95% confidence interval 1.06-1.19; P<0.001). Elevated SAA levels found among women with primary unexplained REPL could represent a novel biomarker for this complication of pregnancy. © 2016 International Federation of Gynecology and Obstetrics.
Autonomic regulation in fetuses with Congenital Heart Disease
Siddiqui, Saira; Wilpers, Abigail; Myers, Michael; Nugent, J. David; Fifer, William P.; Williams, Ismée A.
2015-01-01
Background Exposure to antenatal stressors affects autonomic regulation in fetuses. Whether the presence of congenital heart disease (CHD) alters the developmental trajectory of autonomic regulation is not known. Aims/Study Design This prospective observational cohort study aimed to further characterize autonomic regulation in fetuses with CHD; specifically hypoplastic left heart syndrome (HLHS), transposition of the great arteries (TGA), and tetralogy of Fallot (TOF). Subjects From 11/2010 – 11/2012, 92 fetuses were enrolled: 41 controls and 51 with CHD consisting of 19 with HLHS, 12 with TGA, and 20 with TOF. Maternal abdominal fetal electrocardiogram (ECG) recordings were obtained at 3 gestational ages: 19-27 weeks (F1), 28-33 weeks (F2), and 34-38 weeks (F3). Outcome measures Fetal ECG was analyzed for mean heart rate along with 3 measures of autonomic variability of the fetal heart rate: interquartile range, standard deviation, and root mean square of the standard deviation of the heart rate (RMSSD), a measure of parasympathetic activity. Results During F1 and F2 periods, HLHS fetuses demonstrated significantly lower mean HR than controls (p<0.05). Heart rate variability at F3, as measured by standard deviation, interquartile range, and RMSSD was lower in HLHS than controls (p<0.05). Other CHD subgroups showed a similar, though non-significant trend towards lower variability. Conclusions Autonomic regulation in CHD fetuses differs from controls with HLHS fetuses most markedly affected. PMID:25662702
Crisp, Tom; Khan, Faisal; Padhiar, Nat; Morrissey, Dylan; King, John; Jalan, Rosy; Maffulli, Nicola; Frcr, Otto Chan
2008-01-01
To evaluate a novel conservative management modality for patellar tendinopathy. We recruited nine patients with patellar tendinopathy who had failed conservative management and showed evidence of neovascularisation on power Doppler scanning. A high volume ultrasound guided injection at the interface between the patellar tendon and Hoffa's body. The injection contained 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone, and between 12 and 40 ml normosaline. 100 mm visual analogue scales (VAS) for pain and for function, and Victorian Institute of Sport Assessment - Patellar tendon (VISA-P) questionnaires at an average of 9 months from the injection. All but one patient (whose pain was unchanged) improved (p = 0.028). The mean improvement in function 2 weeks after injection was 58 mm on VAS (interquartile range 27 - 88, p = 0.018). The mean improvement in pain 2 weeks after injection was 56 mm on a VAS scale (interquartile range 32 - 80, p = 0.018). At a mean follow up of 9 months, an improvement of 22 points from a baseline score of 46 on the VISA-P questionnaire (100 being normal) was established. High volume injections to mechanically disrupt the neovascularisation in patellar tendinopathy are helpful in the management of this condition. Controlled trials would be warranted to investigate in a more conclusive fashion this management modality.
Soil organic carbon and total nitrogen pools in permafrost zones of the Qinghai-Tibetan Plateau.
Zhao, Lin; Wu, Xiaodong; Wang, Zhiwei; Sheng, Yu; Fang, Hongbing; Zhao, Yonghua; Hu, Guojie; Li, Wangping; Pang, Qiangqiang; Shi, Jianzong; Mo, Bentian; Wang, Qian; Ruan, Xirui; Li, Xiaodong; Ding, Yongjian
2018-02-26
There are several publications related to the soil organic carbon (SOC) on the Qinghai-Tibetan Plateau (QTP). However, most of these reports were from different parts of the plateau with various sampling depth. Here, we present the results from a systematic sampling and analysis of 200 soil pits. Most of the pits were deeper than 2 m from an east-west transect across the plateau. The SOC and total nitrogen (TN) pools of the 148 × 10 4 km 2 , the area of the permafrost zone, for the upper 2 m soils calculated from the vegetation map were estimated to be 17.07 Pg (interquartile range: 11.34-25.33 Pg) and 1.72 Pg (interquartile range: 1.08-2.06 Pg), respectively. We also predicted the distribution of land cover types in 2050 and 2070 using decision tree rules and climate scenarios, and then predicted SOC and TN pools of this region. The results suggested that the SOC and TN pools will decrease in the future. The results not only contribute to the carbon and nitrogen storage and stocks in the permafrost regions as a whole but most importantly, to our knowledge of the possible changes of C and N storage on the QTP in the future.
Noveanu, Markus; Breidthardt, Tobias; Cayir, Sevgi; Potocki, Mihael; Laule, Kirsten; Mueller, Christian
2009-09-01
Obesity may reduce diagnostic accuracy of B-type natriuretic peptide (BNP) and affect long-term outcome. This study evaluated patients included in the BASEL study (N = 452). We compared BNP levels in patients with (n = 86) and without (n = 366) obesity (body mass index <30 and >30 kg/m(2)) and determined sensitivities and specificities of BNP in both patient groups by receiver-operating characteristic analysis. Impact of BNP measurements on patient management and outcome in obesity, as well as 360-day mortality, was assessed. The BNP levels were lower in obese patients (172 pg/mL [interquartile range 31-515] vs 306 [interquartile range 75-1,040]). The optimal BNP cut-point to detect heart failure was 182 pg/mL in obese patients and 298 pg/mL nonobese patients. Obese patients had lower in-hospital mortality (3.5% vs 8.5%, P = .045) and 360-day mortality (15% vs 30%, P = .001). In obese patients, the determination of BNP levels reduced time to initiation of the appropriate treatment (96 +/- 98 vs 176 +/- 230, P < .05) without impacting other end points. Adjustment of BNP values in the assessment of obese patients presenting with acute dyspnea seems necessary to improve diagnostic accuracy and patient management. Obese patients had half the short- and long-term mortality of nonobese patients, independent of their final discharge diagnosis.
Factors Associated With Mortality in Low-Risk Pediatric Critical Care Patients in The Netherlands.
Verlaat, Carin W; Visser, Idse H; Wubben, Nina; Hazelzet, Jan A; Lemson, Joris; van Waardenburg, Dick; van der Heide, Douwe; van Dam, Nicolette A; Jansen, Nicolaas J; van Heerde, Mark; van der Starre, Cynthia; van Asperen, Roelie; Kneyber, Martin; van Woensel, Job B; van den Boogaard, Mark; van der Hoeven, Johannes
2017-04-01
To determine differences between survivors and nonsurvivors and factors associated with mortality in pediatric intensive care patients with low risk of mortality. Retrospective cohort study. Patients were selected from a national database including all admissions to the PICUs in The Netherlands between 2006 and 2012. Patients less than 18 years old admitted to the PICU with a predicted mortality risk lower than 1% according to either the recalibrated Pediatric Risk of Mortality or the Pediatric Index of Mortality 2 were included. None. In total, 16,874 low-risk admissions were included of which 86 patients (0.5%) died. Nonsurvivors had more unplanned admissions (74.4% vs 38.5%; p < 0.001), had more complex chronic conditions (76.7% vs 58.8%; p = 0.001), were more often mechanically ventilated (88.1% vs 34.9%; p < 0.001), and had a longer length of stay (median, 11 [interquartile range, 5-32] d vs median, 3 [interquartile range, 2-5] d; p < 0.001) when compared with survivors. Factors significantly associated with mortality were complex chronic conditions (odds ratio, 3.29; 95% CI, 1.97-5.50), unplanned admissions (odds ratio, 5.78; 95% CI, 3.40-9.81), and admissions in spring/summer (odds ratio, 1.67; 95% CI, 1.08-2.58). Nonsurvivors in the PICU with a low predicted mortality risk have recognizable risk factors including complex chronic condition and unplanned admissions.
Autonomic regulation in fetuses with congenital heart disease.
Siddiqui, Saira; Wilpers, Abigail; Myers, Michael; Nugent, J David; Fifer, William P; Williams, Ismée A
2015-03-01
Exposure to antenatal stressors affects autonomic regulation in fetuses. Whether the presence of congenital heart disease (CHD) alters the developmental trajectory of autonomic regulation is not known. This prospective observational cohort study aimed to further characterize autonomic regulation in fetuses with CHD; specifically hypoplastic left heart syndrome (HLHS), transposition of the great arteries (TGA), and tetralogy of Fallot (TOF). From 11/2010 to 11/2012, 92 fetuses were enrolled: 41 controls and 51 with CHD consisting of 19 with HLHS, 12 with TGA, and 20 with TOF. Maternal abdominal fetal electrocardiogram (ECG) recordings were obtained at 3 gestational ages: 19-27 weeks (F1), 28-33 weeks (F2), and 34-38 weeks (F3). Fetal ECG was analyzed for mean heart rate along with 3 measures of autonomic variability of the fetal heart rate: interquartile range, standard deviation, and root mean square of the standard deviation of the heart rate (RMSSD), a measure of parasympathetic activity. During F1 and F2 periods, HLHS fetuses demonstrated significantly lower mean HR than controls (p<0.05). Heart rate variability at F3, as measured by standard deviation, interquartile range, and RMSSD was lower in HLHS than controls (p<0.05). Other CHD subgroups showed a similar, though non-significant trend towards lower variability. Autonomic regulation in CHD fetuses differs from controls, with HLHS fetuses most markedly affected. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kim, Hyun-Jung; Kim, Jin-Tae; Kim, Hee-Soo; Kim, Chong-Sung; Kim, Seong-Deok
2011-04-01
The relative effectiveness of GlideScope(®) videolaryngoscopy (GV) for nasotracheal intubation in pediatric patients is unclear. The purpose of this study is to evaluate the usefulness of GV for nasotracheal intubation compared with direct laryngoscopy (DL) in pediatric patients. Our patient cohort consisted of 80 children <10 years of age who required nasotracheal intubation for elective dental or facial surgery. The patients were randomly allocated to GV (n = 40) or DL (n = 40) group. The time to intubation (TTI), glottic view grade, frequency of Magill forceps use, and degree of difficulty in intubation were evaluated. The median TTI was similar between the groups. The TTI of the former 20 patients was faster in the DL group (53.3 s, interquartile range: 42.0-64.3) than GV group (65.9 s, interquartile range: 56.0-93.9) (P = 0.007), whereas the TTI of the latter 20 patients was comparable between the groups. There were no significant differences in glottic view grade, frequency of Magill forceps use, and degree of difficulty in intubation between the two groups. GV can provide similar intubation performance characteristics compared with DL when used for nasotracheal intubation in pediatric patients. However, experience is needed to be skillful in the GV to acquire comparable TTI with DL. © 2011 Blackwell Publishing Ltd.
Berney, Susan C; Rose, Joleen W; Bernhardt, Julie; Denehy, Linda
2015-08-01
Critical illness can result in impaired physical function. Increased physical activity, additional to rehabilitation, has demonstrated improved functional independence at hospital discharge. The purpose of this study was to measure patterns of physical activity in a group of critically ill patients. This was a single-center, open, observational behavioral mapping study performed in a quaternary intensive care unit (ICU) in Melbourne, Australia. Observations were collected every 10 minutes for 8 hours between 8:00 am and 5:00 pm with the highest level of physical activity, patient location, and persons present at the bedside recorded. Two thousand fifty observations were collected across 8 days. Patients spent more than 7 hours in bed (median [interquartile range] of 100% [69%-100%]) participating in little or no activity for approximately 7 hours of the day (median [interquartile range] 96% [76%-96%]). Outside rehabilitation, no activities associated with ambulation were undertaken. Patients who were ventilated at the time of observation compared with those who were not were less likely to be out of bed (98% reduction in odds). Patients spent up to 30% of their time alone. Outside rehabilitation, patients in ICU are inactive and spend approximately one-third of the 8-hour day alone. Strategies to increase physical activity levels in ICU are required. Copyright © 2015 Elsevier Inc. All rights reserved.
Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial.
Suzuki, Satoshi; Woinarski, Nicholas C Z; Lipcsey, Miklos; Candal, Cristina Lluch; Schneider, Antoine G; Glassford, Neil J; Eastwood, Glenn M; Bellomo, Rinaldo
2014-12-01
The aim of this study is to study the feasibility, safety, and physiological effects of pulse pressure variation (PPV)-guided fluid therapy in patients after cardiac surgery. We conducted a pilot prospective before-and-after study during mandatory ventilation after cardiac surgery in a tertiary intensive care unit. We introduced a protocol to deliver a fluid bolus for a PPV≥13% for at least >10 minutes during the intervention period. We studied 45 control patients and 53 intervention patients. During the intervention period, clinicians administered a fluid bolus on 79% of the defined PPV trigger episodes. Median total fluid intake was similar between 2 groups during mandatory ventilation (1297 mL [interquartile range 549-1968] vs 1481 mL [807-2563]; P=.17) and the first 24 hours (3046 mL [interquartile range 2317-3982] vs 3017 mL [2192-4028]; P=.73). After adjusting for several baseline factors, PPV-guided fluid management significantly increased fluid intake during mandatory ventilation (P=.004) but not during the first 24 hours (P=.47). Pulse pressure variation-guided fluid therapy, however, did not significantly affect hemodynamic, renal, and metabolic variables. No serious adverse events were noted. Pulse pressure variation-guided fluid management was feasible and safe during mandatory ventilation after cardiac surgery. However, its advantages may be clinically small. Copyright © 2014 Elsevier Inc. All rights reserved.
Colacino, Justin A; Arthur, Anna E; Ferguson, Kelly K; Rozek, Laura S
2014-05-01
Chronic cadmium exposure may cause disease through induction of systemic oxidative stress and inflammation. Factors that mitigate cadmium toxicity and could serve as interventions in exposed populations have not been well characterized. We used data from the 2003-2010 National Health and Nutrition Examination Survey to quantify diet׳s role in modifying associations between cadmium exposure and oxidative stress and inflammation. We created a composite antioxidant and anti-inflammatory diet score (ADS) by ranking participants by quintile of intake across a panel of 19 nutrients. We identified associations and effect modification between ADS, urinary cadmium, and markers of oxidative stress and inflammation by multiple linear regression. An interquartile range increase in urinary cadmium was associated with a 47.5%, 8.8%, and 3.7% increase in C-reactive protein (CRP), gamma glutamyl transferase (GGT), and alkaline phosphatase (ALP), respectively. An interquartile range increase in ADS was associated with an 7.4%, 3.3%, 5.2%, and 2.5% decrease in CRP, GGT, ALP, and total white blood cell count respectively, and a 3.0% increase in serum bilirubin. ADS significantly attenuated the association between cadmium exposure, CRP and ALP. Dietary interventions may provide a route to reduce the impact of cadmium toxicity on the population level. Copyright © 2014 Elsevier Inc. All rights reserved.
Lung transplantation for high-risk patients with idiopathic pulmonary fibrosis.
De Oliveira, Nilto C; Julliard, Walker; Osaki, Satoru; Maloney, James D; Cornwell, Richard D; Sonetti, David A; Meyer, Keith C
2016-10-07
Survival for patients with idiopathic pulmonary fibrosis (IPF) and high lung allocation score (LAS) values may be significantly reduced in comparison to those with lower LAS values. To evaluate outcomes for high-risk IPF patients as defined by LAS values ≥46 (N=42) versus recipients with LAS values <46 (N=89). We retrospectively reviewed records of 131 consecutive patients with IPF who received lung transplants at our institution between 1999 and 2013. The mean LAS was significantly higher (59.5, interquartile range 43.9-75.9 vs. 39.3, interquartile range 37.7-44.3; p<0.01) for the high-risk cohort. The higher LAS cohort had significantly lower percent predicted forced vital capacity (FVC) versus recipients with LAS <46 (41.3±14.1% vs. 53.2±16.2%; p<0.01) and required more supplemental oxygen (7±5 vs. 4±2 L/min, p<0.01) prior to transplant versus recipients with LAS <46. Although the incidence of early post-LTX pulmonary complications was increased for the higher LAS group versus recipients with LAS <46, 30-day mortality and actuarial survival did not differ between the two cohorts. Although lung transplantation in patients with IPF and high LAS values is associated with increased risk of early post-transplant complications, long-term post-transplant survival for our high-LAS cohort was equivalent to that for the lower LAS recipients.
The use of theatre time for paediatric dentistry under general anaesthesia.
Foley, Jennifer; Soldani, Francesca
2007-01-01
The aim of this paper was to determine the use of theatre time for all procedures performed under general anaesthetic on a paediatric dental list. A prospective study of paediatric dental general anaesthetic procedures was undertaken at Ninewells Hospital and Medical School, NHS Tayside, Dundee, UK. Data were collected prospectively for 71 operating lists over a 3-year period from April 2003 to March 2006. Both operator status and the procedure being undertaken were recorded. In addition, pre-anaesthetic, anaesthetic, operating and disconnection times were recorded. Of the 71 lists examined, 61 either finished early or on time, with a median unused time of 32.50 min (interquartile range = 19.50, 50.00 min), whilst 10 lists finished late with a median overrun time of 30.50 min (interquartile range = 9.25, 45.50 min). Comparing lists which finished late with those which were completed within time, the median pre-anaesthetic time was significantly longer (Mann-Whitney U-test, W = 20.05, P = 0.048). Overall, the theatre was in use for 78.22% of time combining pre-anaesthetic, anaesthetic, operating and disconnection times; hence, there was poor time utilization of theatre for 21.78% of the total theatre time. Overall, 85.9% of theatre sessions for dental procedures under general anaesthetic in children finished early or on time. Where lists finished late, the duration of the pre-anaesthetic time appeared to be the significant factor.
Early neurodevelopmental outcomes of infants with intestinal failure.
So, Stephanie; Patterson, Catherine; Gold, Anna; Rogers, Alaine; Kosar, Christina; de Silva, Nicole; Burghardt, Karolina Maria; Avitzur, Yaron; Wales, Paul W
2016-10-01
The survival rate of infants and children with intestinal failure is increasing, necessitating a greater focus on their developmental trajectory. To evaluate neurodevelopmental outcomes in children with intestinal failure at 0-15months corrected age. Analysis of clinical, demographic and developmental assessment results of 33 children followed in an intestinal rehabilitation program between 2011 and 2014. Outcome measures included: Prechtl's Assessment of General Movements, Movement Assessment of Infants, Alberta Infant Motor Scale and Mullen Scales of Early Learning. Clinical factors were correlated with poorer developmental outcomes at 12-15months corrected age. Thirty-three infants (17 males), median gestational age 34weeks (interquartile range 29.5-36.0) with birth weight 1.98kg (interquartile range 1.17-2.50). Twenty-nine (88%) infants had abnormal General Movements. More than half had suspect or abnormal scores on the Alberta Infant Motor Scale and medium to high-risk scores for future neuromotor delay on the Movement Assessment of Infants. Delays were seen across all Mullen subscales, most notably in gross motor skills. Factors significantly associated with poorer outcomes at 12-15months included: prematurity, low birth weight, central nervous system co-morbidity, longer neonatal intensive care admission, necrotizing enterocolitis diagnosis, number of operations and conjugated hyperbilirubinemia. Multiple risk factors contribute to early developmental delay in children with intestinal failure, highlighting the importance of close developmental follow-up. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Taylor, Darlene; Durigon, Monica; Davis, Heather; Archibald, Chris; Konrad, Bernhard; Coombs, Daniel; Gilbert, Mark; Cook, Darrel; Krajden, Mel; Wong, Tom; Ogilvie, Gina
2015-03-01
Failure to understand the risk of false-negative HIV test results during the window period results in anxiety. Patients typically want accurate test results as soon as possible while clinicians prefer to wait until the probability of a false-negative is virtually nil. This review summarizes the median window periods for third-generation antibody and fourth-generation HIV tests and provides the probability of a false-negative result for various days post-exposure. Data were extracted from published seroconversion panels. A 10-day eclipse period was used to estimate days from infection to first detection of HIV RNA. Median (interquartile range) days to seroconversion were calculated and probabilities of a false-negative result at various time periods post-exposure are reported. The median (interquartile range) window period for third-generation tests was 22 days (19-25) and 18 days (16-24) for fourth-generation tests. The probability of a false-negative result is 0.01 at 80 days' post-exposure for third-generation tests and at 42 days for fourth-generation tests. The table of probabilities of falsely-negative HIV test results may be useful during pre- and post-test HIV counselling to inform co-decision making regarding the ideal time to test for HIV. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, Jay P.; Levy, Larry; Oh, Julia L.
Purpose: To examine the outcome of patients who developed an isolated locoregional recurrence (LRR) involving the supraclavicular fossa (SCV) after initial treatment with modified radical mastectomy and chemotherapy. Methods and Materials: Records from 140 breast cancer patients treated on five prospective trials with mastectomy and doxorubicin-based chemotherapy, with or without radiation, who developed a LRR were reviewed. Kaplan-Meier survival times were calculated using date of LRR as time zero. Results: The median follow-up after LRR was 2.9 years (N = 140; interquartile range, 1.3-6.6 years). In all, 47 of 140 patients (34%) had an SCV component to their LRR. Thesemore » patients had lower 3-y distant metastasis-free survival (40% vs. 54%, p = 0.003) and overall survival (49% vs. 69%, p = 0.04) than patients without an SCV component. Multivariate analysis revealed that LRR involving an SCV component (hazard ratio, 1.96, p = 0.004) and patients with lymphovascular space invasion in their primary tumors (hazard ratio, 1.65, p = 0.029) were independently associated with a poor distant metastasis-free survival. However, among 23 patients with isolated SCV recurrence, Overall survival was not statistically significantly different between isolated chest wall recurrence and isolated SCV recurrence. Patients with isolated SCV recurrence displayed a median follow-up of 3.3 years (IR, 1.2-5.2). Only 6 LRR of 23 patients were treated with aggressive local therapy, including surgery, chemotherapy, and radiation (alone or in combination). Conclusions: Although breast cancer recurrence with SCV involvement carries a high risk of distant metastasis and death, among women with recurrence limited to the SCV alone, overall survival after isolated SCV recurrence can be long (25% >5 years).« less
Mubarak, Muhammed; Shakeel, Shaheera; Abbas, Khawar; Aziz, Tahir; Zafar, Mirza Naqi; Naqvi, Syed Anwer; Rizvi, Syed Adibul Hasan
2017-02-01
Our aim was to determine the clinical significance of borderline lymphocytic infiltrates on indicated renal allograft biopsies in a living related renal transplant setting. The study was conducted at the histopathology department of Sindh Institute of Urology and Transplantation. A retrospective review of 421 renal transplant patients was conducted from October 2007 to September 2008 to identify patients in whom a histologic diagnosis of borderline changes was made on dysfunctional renal allograft biopsies. Demographic, clinical, and laboratory data; biopsy findings; treatments given; and responses to treatment were collected and analyzed. Standard biopsy indications determined the need for graft biopsies. Biopsies were reported according to Banff criteria. Mean age was 26.92 ± 9.14 years (range, 10-45) for recipients and 38.46 ± 9.16 years (range, 19-50) for donors. Males were predominant among recipients (84.6% vs 15.4%), and females were predominant among donors (57.7% vs 42.3%). The best serum creatinine levels were 1.79 ± 1.15 mg/dL (range, 0.83-6.12). These were achieved after a median of 3 days (interquartile range, 2-7.25). Dysfunctional biopsies exhibiting borderline infiltrates were performed at a median duration of 5.5 days (interquartile range, 3-14.25). Mean serum creatinine at the time of biopsy was 2.34 ± 1.43 mg/dL (range, 1.25-8.25). The biopsies showed borderline cellular infiltrates (interstitial inflammation 1 [i1] and tubulitis 1 and [t1] lesions). All recipients except one received antirejection treatment (antithymocyte globulin, n = 5; escalation of mycophenolate mofetil dosage, n = 1; pulse steroids, n = 19); all recipients responded with a decline in serum creatinine toward baseline, with a mean serum creatinine of 1.31 ± 0.42 mg/dL (range, 0.40-2.71). This response was achieved at a median duration of 9.73 ± 5.32 days (range, 1-23) after starting treatment. The borderline cellular infiltrates on dysfunctional renal allograft biopsies signify evolving phases of acute cellular rejection. These infiltrates responded favorably to antirejection treatment in our setting.
IR characteristic simulation of city scenes based on radiosity model
NASA Astrophysics Data System (ADS)
Xiong, Xixian; Zhou, Fugen; Bai, Xiangzhi; Yu, Xiyu
2013-09-01
Reliable modeling for thermal infrared (IR) signatures of real-world city scenes is required for signature management of civil and military platforms. Traditional modeling methods generally assume that scene objects are individual entities during the physical processes occurring in infrared range. However, in reality, the physical scene involves convective and conductive interactions between objects as well as the radiations interactions between objects. A method based on radiosity model describes these complex effects. It has been developed to enable an accurate simulation for the radiance distribution of the city scenes. Firstly, the physical processes affecting the IR characteristic of city scenes were described. Secondly, heat balance equations were formed on the basis of combining the atmospheric conditions, shadow maps and the geometry of scene. Finally, finite difference method was used to calculate the kinetic temperature of object surface. A radiosity model was introduced to describe the scattering effect of radiation between surface elements in the scene. By the synthesis of objects radiance distribution in infrared range, we could obtain the IR characteristic of scene. Real infrared images and model predictions were shown and compared. The results demonstrate that this method can realistically simulate the IR characteristic of city scenes. It effectively displays the infrared shadow effects and the radiation interactions between objects in city scenes.
Cramer, Joel; Seifert, Tom; Kronenberg, Alexander; Fuhrmann, Felix; Jakob, Gerhard; Jourdan, Martin; Kampfrath, Tobias; Kläui, Mathias
2018-02-14
We measure the inverse spin Hall effect of Cu 1-x Ir x thin films on yttrium iron garnet over a wide range of Ir concentrations (0.05 ⩽ x ⩽ 0.7). Spin currents are triggered through the spin Seebeck effect, either by a continuous (dc) temperature gradient or by ultrafast optical heating of the metal layer. The spin Hall current is detected by electrical contacts or measurement of the emitted terahertz radiation. With both approaches, we reveal the same Ir concentration dependence that follows a novel complex, nonmonotonous behavior as compared to previous studies. For small Ir concentrations a signal minimum is observed, whereas a pronounced maximum appears near the equiatomic composition. We identify this behavior as originating from the interplay of different spin Hall mechanisms as well as a concentration-dependent variation of the integrated spin current density in Cu 1-x Ir x . The coinciding results obtained for dc and ultrafast stimuli provide further support that the spin Seebeck effect extends to terahertz frequencies, thus enabling a transfer of established spintronic measurement schemes into the terahertz regime. Our findings also show that the studied material allows for efficient spin-to-charge conversion even on ultrafast time scales.
Metal-Insulator Transition in Epitaxial Pyrochlore Iridates Bi2Ir2O7 thin Films
NASA Astrophysics Data System (ADS)
Chu, Jiun-Haw; Liu, Jian; Yi, Di; Rayan-Serrao, C.; Suresha, S.; Marti, Xavi; Riggs, Scott; Shapiro, Max; Ian, Fisher; Ramesh, R.
2013-03-01
Recently there is a surge of interest in searching for topological order in correlated electronic systems such as transition metal oxides. The strong spin-orbit interaction of 5d electrons and the geometric frustration in the crystal lattice make the pyrochlore iridate(A2Ir2O7) an ideal candidate to achieve this goal. Pioneering experiments on bulk polycrystalline and single crystal samples revealed a temperature dependent metal-insulator transition coupled to a long range magnetic order, and the transition temperature can be tuned by either A-site ionic radius or an external pressure. In this talk we present our efforts to understand and control the metal-insulator transition and the underlying electronic structure of pyrochlore iridates via epitaxial Bi2Ir2O7 thin films. Bulk Bi2Ir2O7 is located at the metallic side of the phase diagram. However as the film's thickness decreases the transport evolves from a metallic to a strongly localized character. Resonant X-ray spectroscopy suggests that the density of states near Fermi level is dominated by the Ir Je ff =1/2 states. Intriguingly, the magnetoresistance shows a linear field dependence over a wide range of fields at low temperatures, which is possibly consistent with the existence of Dirac nodes.
VERY LARGE INTERSTELLAR GRAINS AS EVIDENCED BY THE MID-INFRARED EXTINCTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Shu; Jiang, B. W.; Li, Aigen, E-mail: shuwang@mail.bnu.edu.cn, E-mail: bjiang@bnu.edu.cn, E-mail: wanshu@missouri.edu, E-mail: lia@missouri.edu
The sizes of interstellar grains are widely distributed, ranging from a few angstroms to a few micrometers. The ultraviolet (UV) and optical extinction constrains the dust in the size range of a couple hundredths of micrometers to several submicrometers. The near and mid infrared (IR) emission constrains the nanometer-sized grains and angstrom-sized very large molecules. However, the quantity and size distribution of micrometer-sized grains remain unknown because they are gray in the UV/optical extinction and they are too cold and emit too little in the IR to be detected by IRAS, Spitzer, or Herschel. In this work, we employ themore » ∼3–8 μm mid-IR extinction, which is flat in both diffuse and dense regions to constrain the quantity, size, and composition of the μm-sized grain component. We find that, together with nano- and submicron-sized silicate and graphite (as well as polycyclic aromatic hydrocarbons), μm-sized graphite grains with C/H ≈ 137 ppm and a mean size of ∼1.2 μm closely fit the observed interstellar extinction of the Galactic diffuse interstellar medium from the far-UV to the mid-IR, as well as the near-IR to millimeter thermal emission obtained by COBE/DIRBE, COBE/FIRAS, and Planck up to λ ≲ 1000 μm. The μm-sized graphite component accounts for ∼14.6% of the total dust mass and ∼2.5% of the total IR emission.« less
Bennell, K; Khan, K; Matthews, B; Singleton, C
2001-01-01
Objectives—To evaluate in a 12 month longitudinal study changes in hip and ankle range of motion and hip muscle strength in young female novice ballet dancers. Methods—Fifty three of the original 77 (69%) female dancers aged 8–11 years and 40 of the original 49 (82%) controls returned for follow up measurements one year later. Supine right active hip external (ER) and internal (IR) rotation were measured using an inclinometer. A turnout protractor was used to assess standing active turnout range. Range of right weight bearing ankle dorsiflexion and calf muscle length were measured in a standing lunge position using an inclinometer. A manual muscle tester was used to assess right hip flexor, IR, ER, abductor and adductor strength. Results—The mean (SD) 12 month change in hip ER did not differ between dancers (11.7 (11.3)°) and controls (8.1 (17.6)°). Dancers gained 12.5 (13.5)° hip IR which was significantly greater than controls (0.5 (13.9)°). Greater IR change was associated with improved IR strength (r = 0.34, p<0.001). Dancers increased total turnout (12.0 (16.7)°) significantly more than controls (2.2 (20.0)°). There was no significant change in ankle dorsiflexion range in either group. Dancers and controls increased in all measures of hip muscle strength (p<0.001) and dancers achieved significantly greater gains in three out of five muscle groups (all, p<0.05). Conclusions—Total hip range of motion increased in both ballet students and controls at this young age. However, ankle dorsiflexion did not, which is probably due to this movement being blocked by bony apposition, rather than soft tissue stretch. This has implications for ballet teachers, as it has long been accepted that this movement could be improved with training. Dancers had greater increases in hip strength after 12 months compared with controls in muscles specific for ballet, suggesting that hip strength can be trained at this young age. Whether these gains are permanent requires further study. Key Words: dance; ballet; range of motion; muscle strength PMID:11157464
Larkin, James; Chmielowski, Bartosz; Lao, Christopher D; Hodi, F Stephen; Sharfman, William; Weber, Jeffrey; Suijkerbuijk, Karijn P M; Azevedo, Sergio; Li, Hewei; Reshef, Daniel; Avila, Alexandre; Reardon, David A
2017-06-01
Despite unprecedented efficacy across multiple tumor types, immune checkpoint inhibitor therapy is associated with a unique and wide spectrum of immune-related adverse events (irAEs), including neurologic events ranging from mild headache to potentially life-threatening encephalitis. Here, we summarize neurologic irAEs associated with nivolumab and ipilimumab melanoma treatment, present cases of treatment-related encephalitis, and provide practical guidance on diagnosis and management. We searched a Global Pharmacovigilance and Epidemiology database for neurologic irAEs reported over an 8-year period in patients with advanced melanoma receiving nivolumab with or without ipilimumab from 12 studies sponsored by Bristol-Myers Squibb. Serious neurologic irAEs were reviewed, and relationship to nivolumab or ipilimumab was assigned. In our search of 3,763 patients, 35 patients (0.93%) presented with 43 serious neurologic irAEs, including neuropathy ( n = 22), noninfective meningitis ( n = 5), encephalitis ( n = 6), neuromuscular disorders ( n = 3), and nonspecific adverse events ( n = 7). Study drug was discontinued ( n = 20), interrupted ( n = 8), or unchanged ( n = 7). Most neurologic irAEs resolved (26/35 patients; 75%). Overall, median time to onset was 45 days (range 1-170) and to resolution was 32 days (2-809+). Median time to onset of encephalitis was 55.5 days (range 18-297); four cases resolved and one was fatal. Both oncologists and neurologists need to be aware of signs and symptoms of serious but uncommon neurologic irAEs associated with checkpoint inhibitors. Prompt diagnosis and management using an established algorithm are critical to minimize serious complications from these neurologic irAEs. With increasing use of checkpoint inhibitors in cancer, practicing oncologists need to be aware of the potential risk of neurologic immune-related adverse events and be able to provide prompt treatment of this uncommon, but potentially serious, class of adverse events. We summarize neurologic adverse events related to nivolumab alone or in combination with ipilimumab in patients with advanced melanoma from 12 studies and examine in depth 6 cases of encephalitis. We also provide input and guidance on the existing neurologic adverse events management algorithm for nivolumab and ipilimumab. © AlphaMed Press 2017.
Chmielowski, Bartosz; Lao, Christopher D.; Hodi, F. Stephen; Sharfman, William; Weber, Jeffrey; Suijkerbuijk, Karijn P. M.; Azevedo, Sergio; Li, Hewei; Reshef, Daniel; Avila, Alexandre; Reardon, David A.
2017-01-01
Abstract Background. Despite unprecedented efficacy across multiple tumor types, immune checkpoint inhibitor therapy is associated with a unique and wide spectrum of immune‐related adverse events (irAEs), including neurologic events ranging from mild headache to potentially life‐threatening encephalitis. Here, we summarize neurologic irAEs associated with nivolumab and ipilimumab melanoma treatment, present cases of treatment‐related encephalitis, and provide practical guidance on diagnosis and management. Methods. We searched a Global Pharmacovigilance and Epidemiology database for neurologic irAEs reported over an 8‐year period in patients with advanced melanoma receiving nivolumab with or without ipilimumab from 12 studies sponsored by Bristol‐Myers Squibb. Serious neurologic irAEs were reviewed, and relationship to nivolumab or ipilimumab was assigned. Results. In our search of 3,763 patients, 35 patients (0.93%) presented with 43 serious neurologic irAEs, including neuropathy (n = 22), noninfective meningitis (n = 5), encephalitis (n = 6), neuromuscular disorders (n = 3), and nonspecific adverse events (n = 7). Study drug was discontinued (n = 20), interrupted (n = 8), or unchanged (n = 7). Most neurologic irAEs resolved (26/35 patients; 75%). Overall, median time to onset was 45 days (range 1–170) and to resolution was 32 days (2–809+). Median time to onset of encephalitis was 55.5 days (range 18–297); four cases resolved and one was fatal. Conclusion. Both oncologists and neurologists need to be aware of signs and symptoms of serious but uncommon neurologic irAEs associated with checkpoint inhibitors. Prompt diagnosis and management using an established algorithm are critical to minimize serious complications from these neurologic irAEs. Implications for Practice. With increasing use of checkpoint inhibitors in cancer, practicing oncologists need to be aware of the potential risk of neurologic immune‐related adverse events and be able to provide prompt treatment of this uncommon, but potentially serious, class of adverse events. We summarize neurologic adverse events related to nivolumab alone or in combination with ipilimumab in patients with advanced melanoma from 12 studies and examine in depth 6 cases of encephalitis. We also provide input and guidance on the existing neurologic adverse events management algorithm for nivolumab and ipilimumab. PMID:28495807
Synthesis of monoclinic IrTe 2 under high pressure and its physical properties
Li, X.; Yan, J. -Q.; Singh, D. J.; ...
2015-10-12
In a pressure-temperature (P-T) diagram for synthesizing IrTe 2 compounds, the well-studied trigonal (H) phase with the CdI 2-type structure is stable at low pressures. The superconducting cubic (C) phase can be synthesized under higher temperatures and pressures. A rhombohedral phase with the crystal structure similar to the C phase can be made at ambient pressure; but the phase contains a high concentration of Ir deficiency. Here, we report that a rarely studied monoclinic (M) phase can be stabilized in narrow ranges of pressure and temperature in this P-T diagram. Moreover, the peculiar crystal structure of the M-IrTe 2 eliminatesmore » the tendency to form Ir-Ir dimers found in the H phase. The M phase has been fully characterized by structural determination and measurements of electrical resistivity, thermoelectric power, DC magnetization, and specific heat. These physical properties have been compared with those in the H and C phases of Ir 1-xTe 2. Finally, we present magnetic and transport properties and specific heat of the M-IrTe 2 can be fully justified by calculations with the density-functional theory.« less
FT-IR and DFT study of lemon peel
NASA Astrophysics Data System (ADS)
Berezin, K. V.; Likhter, A. M.; Shagautdinova, I. T.; Chernavina, M. L.; Novoselova, A. V.
2017-03-01
Experimental FT-IR spectra of lemon peel are registered in the 650 - 3800 cm-1 range. The influence of peel artificial and natural dehydration on its vibrational spectrum is studied. The colored outer surface of lemon peel is proved not to have a significant impact on FT-IR spectrum. It is determined that only dehydration processes affect the FT-IR vibrational spectrum of the peel when a lemon is stored for 28 days under natural laboratory conditions. Polymer molecule models for dietary fibers, such as cellulose, hemicellulose, pectin, lignin, as well as hesperidin - flavonoid glycoside, and free moisture cluster are developed within the framework of DFT/B3LYP/6-31G(d) theoretical method. By implementing supramolecular approach, modeling of the vibrational FT-IR spectrum of lemon peel is carried out and its detailed theoretical interpretation is presented.
A dual-band adaptor for infrared imaging.
McLean, A G; Ahn, J-W; Maingi, R; Gray, T K; Roquemore, A L
2012-05-01
A novel imaging adaptor providing the capability to extend a standard single-band infrared (IR) camera into a two-color or dual-band device has been developed for application to high-speed IR thermography on the National Spherical Tokamak Experiment (NSTX). Temperature measurement with two-band infrared imaging has the advantage of being mostly independent of surface emissivity, which may vary significantly in the liquid lithium divertor installed on NSTX as compared to that of an all-carbon first wall. In order to take advantage of the high-speed capability of the existing IR camera at NSTX (1.6-6.2 kHz frame rate), a commercial visible-range optical splitter was extensively modified to operate in the medium wavelength and long wavelength IR. This two-band IR adapter utilizes a dichroic beamsplitter, which reflects 4-6 μm wavelengths and transmits 7-10 μm wavelength radiation, each with >95% efficiency and projects each IR channel image side-by-side on the camera's detector. Cutoff filters are used in each IR channel, and ZnSe imaging optics and mirrors optimized for broadband IR use are incorporated into the design. In-situ and ex-situ temperature calibration and preliminary data of the NSTX divertor during plasma discharges are presented, with contrasting results for dual-band vs. single-band IR operation.
Local structural aspects of metal-metal transition in IrTe2 from x-ray PDF
NASA Astrophysics Data System (ADS)
Yu, Runze; Abeykoon, Milinda; Zhou, Haidong; Yin, Weiguo; Bozin, Emil S.
Evolution of local atomic structure across the metal-metal transition in IrTe2 is explored by pair distribution function (PDF) analysis of x-ray total scattering data over 80 K
Natterer, F D; Rusponi, S; Papagno, M; Carbone, C; Brune, H
2012-08-08
We compare different growth methods with the aim of optimizing the long-range order of a graphene layer grown on Ru(0001). Combining chemical vapor deposition with carbon loading and segregation of the surface layer leads to autocorrelation lengths of 240 Å. We present several routes to band gap and charge carrier mobility engineering for the example of graphene on Ir(111). Ir cluster superlattices self-assembled onto the graphene moiré pattern produce a strong renormalization of the electron group velocity close to the Dirac point, leading to highly anisotropic Dirac cones and the enlargement of the gap from 140 to 340 meV. This gap can further be enhanced to 740 meV by Na co-adsorption onto the Ir cluster superlattice at room temperature. This value is close to that of Ge, and the high group velocity of the charge carriers is fully preserved. We also present data for Na adsorbed without the Ir clusters. In both cases we find that the Na is on top of the graphene layer.
NASA Astrophysics Data System (ADS)
Antoniou, P. E.; Bousbouras, P.; Sandaltzopoulos, R.; Kaldoudi, E.
2008-04-01
Complex interventional radiology (IR) procedures contribute an increasing percentage of the overall medical radiation exposure of the population making accurate dosimetry a challenge. Magnetic resonance (MR) based polymer gel dosimetry has been widely employed in complex dosimetric problems in radiotherapy. The aim of this note is to investigate the feasibility of normoxic gel dosimetry in IR. Dose response, energy dependence and dose rate dependence were investigated in irradiation set-ups relevant to IR for a particular normoxic gel, based on methacrylic acid (MAA) as the monomer and including tetrakis-hydroxy-methyl-phosphonium chloride (THPC) as antioxidant. The gel presents a linear dose response beyond a 25 cGy threshold. No significant energy dependence was observed in the useful range of interventional radiology (80-110 kVp). A linear correlation between the gel response and dose rate was observed in the range of dose rates relevant to IR (5-8 cGy min-1). These results demonstrate a reduction of gel sensitivity at very low dose rate levels. A possible explanation of this effect is suggested.
The "PHS Increased Risk" Label Is Associated With Nonutilization of Hundreds of Organs per Year.
Volk, Michael L; Wilk, Amber R; Wolfe, Cameron; Kaul, Daniel R
2017-07-01
The Public Health Service "Increased Risk" (PHS IR) designation identifies donors at increased risk of transmitting hepatitis B, C, and human immunodeficiency virus. Although the risk remains very low in the era of nucleic acid testing, we hypothesized that this label may result in decreased organ utilization. Organ Procurement and Transplantation Network data were used to compare utilization rates between PHS-IR and non-PHS-IR donors, as well as to compare export rates and variation in utilization. Among adult standard criteria donors between 2010 and 2013 with a known PHS-IR status, covariate-adjusted utilization rates were lower among PHS-IR donors than non-PHS-IR donors for all organs. For example, 4073 (76.7%) of 5314 PHS-IR kidneys were used, compared with 25 490 (83.7%) of 30 456 non-PHS-IR kidneys-an absolute difference of 7%. Furthermore, all PHS-IR organs had higher export rates than non-PHS-IR organs. For example, 28.7% of PHS-IR kidneys were exported versus 19.7% of non-PHS-IR kidneys. Finally, the utilization rate of PHS-IR organs varied by Donation Service Area; utilization ranged from 20% to 100% among adult kidneys, suggesting significant variation in practices. Similar patterns were seen among pediatric donors. Based on the covariate-adjusted model, if the PHS-IR label did not exist, there could be an additional 313 transplants performed in the United States each year. The PHS "increased risk" label appears to be associated with nonutilization of hundreds of organs per year, despite the very low risk of disease transmission. Better tools are needed to communicate the magnitude of risk to patients and their families.
Nanostructured F doped IrO2 electro-catalyst powders for PEM based water electrolysis
NASA Astrophysics Data System (ADS)
Kadakia, Karan Sandeep; Jampani, Prashanth H.; Velikokhatnyi, Oleg I.; Datta, Moni Kanchan; Park, Sung Kyoo; Hong, Dae Ho; Chung, Sung Jae; Kumta, Prashant N.
2014-12-01
Fluorine doped iridium oxide (IrO2:F) powders with varying F content ranging from 0 to 20 wt.% has been synthesized by using a modification of the Adams fusion method. The precursors (IrCl4 and NH4F) are mixed with NaNO3 and heated to elevated temperatures to form high surface area nanomaterials as electro-catalysts for PEM based water electrolysis. The catalysts were then coated on a porous Ti substrate and have been studied for the oxygen evolution reaction in PEM based water electrolysis. The IrO2:F with an optimum composition of IrO2:10 wt.% F shows remarkably superior electrochemical activity and chemical stability compared to pure IrO2. The results have also been supported via kinetic studies by conducting rotating disk electrode (RDE) experiments. The RDE studies confirm that the electro-catalysts follow the two electron transfer reaction for electrolysis with calculated activation energy of ∼25 kJ mol-1. Single full cell tests conducted also validate the superior electrochemical activity of the 10 wt.% F doped IrO2.
Upconversion of the mid-IR pulses to the near-IR in LiGaS2
NASA Astrophysics Data System (ADS)
Kato, Kiyoshi; Umemura, Nobuhiro; Okamoto, Takuya; Petrov, Valentin
2018-02-01
This paper reports on the phase-matching properties of LiGaS2 for upconverting a Nd:YAG laser-pumped KTP and AgGaS2 optical parametric oscillator (OPO) at mid-IR to the near-IR by mixing with its pump source together with the new Sellmeier equations that provide a good reproduction of the present experimental results as well as the published data points of second-harmonic generation (SHG) and sum-frequency generation (SFG) of a CO2 laser, a Ti:Al2O3 laser-pumped optical parametric amplifier (OPA), and a Nd:YAG laser-pumped OPO in the mid-IR. This index formula gives the important information that group velocity mismatch (GVM) (Δsp = 1/υs - 1/υp) of LiGaS2 in the 4 - 11 μm range is 12 27 fs/mm lower than that of the widely used LiInS2, which makes it ideal for the upconversion of the mid-IR femtosecond pulses having large spectral bandwidths to the near-IR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kronbo, Camilla H.; Nielsen, Morten B.; Kevy, Simone M.
The high pressure behaviors of the two perovskite structures (hexagonal 6H-SrIrO{sub 3} and orthorhombic 3C-SrIrO{sub 3}) have been studied in diamond anvil cells to 43 and 60 GPa, respectively, using synchrotron powder X-ray diffraction. 6H-SrIrO{sub 3} was first synthesized at ambient pressure and subsequently transformed into 3C-SrIrO{sub 3} in a large volume press at 8.8 GPa and 1000 °C. Both polymorphs were found to retain the initial symmetry up to the highest pressures measured, but in the case of 6H-SrIrO{sub 3}, two anomalies were identified: a change in the axial compressibilities at 24 GPa and a change in both themore » axial and volume compressibilities at 32 GPa. Fitting a 3rd order Birch-Murnaghan equation of state to the obtained P-V data yielded bulk moduli of K{sub 0}=151.5(12) GPa (fitted range 0« less
Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul
2016-01-01
Context: Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. Objective: To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Design: Cross-sectional study. Setting: University laboratory. Participants: Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m2). Main Outcome Measure(s): Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. Results: External-rotation ROM was greater (t38 = 4.92, P < .001), but IR ROM (t38 = −8.61, P < .001) and total ROM (t38 = −3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t38 = 2.89, P = .006) and eccentric external-rotator (t38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t38 = −3.60, P < .001). Conclusions: Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries. PMID:27813683
Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul
2016-09-01
Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Cross-sectional study. University laboratory. Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m 2 ). Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. External-rotation ROM was greater (t 38 = 4.92, P < .001), but IR ROM (t 38 = -8.61, P < .001) and total ROM (t 38 = -3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t 38 = 2.89, P = .006) and eccentric external-rotator (t 38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t 38 = -3.60, P < .001). Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries.
High performance, low dissipation quantum cascade lasers across the mid-IR range.
Bismuto, Alfredo; Blaser, Stéphane; Terazzi, Romain; Gresch, Tobias; Muller, Antoine
2015-03-09
In this work, we present the development of low consumption quantum cascade lasers across the mid-IR range. In particular, short cavity single-mode lasers with optimised facet reflectivities have been fabricated from 4.5 to 9.2 μm. Threshold dissipated powers as low as 0.5 W were obtained in continuous wave operation at room temperature. In addition, the beneficial impact of reducing chip length on laser mounting yield is discussed. High power single-mode lasers from the same processed wafers are also presented.
Limitations of insulin resistance assessment in polycystic ovary syndrome
Lewandowski, Krzysztof C; Płusajska, Justyna; Horzelski, Wojciech; Bieniek, Ewa; Lewiński, Andrzej
2018-01-01
Background Though insulin resistance (IR) is common in polycystic ovary syndrome (PCOS), there is no agreement as to what surrogate method of assessment of IR is most reliable. Subjects and methods In 478 women with PCOS, we compared methods based on fasting insulin and either fasting glucose (HOMA-IR and QUICKI) or triglycerides (McAuley Index) with IR indices derived from glucose and insulin during OGTT (Belfiore, Matsuda and Stumvoll indices). Results There was a strong correlation between IR indices derived from fasting values HOMA-IR/QUICKI, r = −0.999, HOMA-IR/McAuley index, r = −0.849 and between all OGTT-derived IR indices (e.g. r = −0.876, for IRI/Matsuda, r = −0.808, for IRI/Stumvoll, and r = 0.947, for Matsuda/Stumvoll index, P < 0.001 for all), contrasting with a significant (P < 0.001), but highly variable correlation between IR indices derived from fasting vs OGTT-derived variables, ranging from r = −0.881 (HOMA-IR/Matsuda), through r = 0.58, or r = −0.58 (IRI/HOMA-IR, IRI/QUICKI, respectively) to r = 0.41 (QUICKI/Stumvoll), and r = 0.386 for QUICKI/Matsuda indices. Detailed comparison between HOMA-IR and IRI revealed that concordance between HOMA and IRI was poor for HOMA-IR/IRI values above 75th and 90th percentile. For instance, only 53% (70/132) women with HOMA-IR >75th percentile had IRI value also above 75th percentile. There was a significant, but weak correlation of all IR indices with testosterone concentrations. Conclusions Significant number of women with PCOS can be classified as being either insulin sensitive or insulin resistant depending on the method applied, as correlation between various IR indices is highly variable. Clinical application of surrogate indices for assessment of IR in PCOS must be therefore viewed with an extreme caution. PMID:29436386
Ahmed, Adil; Chandra, Subhash; Herasevich, Vitaly; Gajic, Ognjen; Pickering, Brian W
2011-07-01
The care of critically ill patients generates large quantities of data. Increasingly, these data are presented to the provider within an electronic medical record. The manner in which data are organized and presented can impact on the ability of users to synthesis that data into meaningful information. The objective of this study was to test the hypothesis that novel user interfaces, which prioritize the display of high-value data to providers within system-based packages, reduce task load, and result in fewer errors of cognition compared with established user interfaces that do not. Randomized crossover study. Academic tertiary referral center. Attending, resident and fellow critical care physicians. Novel health care record user interface. Subjects randomly assigned to either a standard electronic medical record or a novel user interface, were asked to perform a structured task. The task required the subjects to use the assigned electronic environment to review the medical record of an intensive care unit patient said to be actively bleeding for data that formed the basis of answers to clinical questions posed in the form of a structured questionnaire. The primary outcome was task load, measured using the paper version of the NASA-task load index. Secondary outcome measures included time to task completion, number of errors of cognition measured by comparison of subject to post hoc gold standard questionnaire responses, and the quantity of information presented to subjects by each environment. Twenty subjects completed the task on eight patients, resulting in 160 patient-provider encounters (80 in each group). The standard electronic medical record contained a much larger data volume with a median (interquartile range) number of data points per patient of 1008 (895-1183) compared with 102 (77-112) contained within the novel user interface. The median (interquartile range) NASA-task load index values were 38.8 (32-45) and 58 (45-65) for the novel user interface compared with the standard electronic medical record (p < .001). The median (interquartile range) times in seconds taken to complete the task for four consecutive patients were 93 (57-132), 60 (48-71), 68 (48-80), and 54 (42-64) for the novel user interface compared with 145 (109-201), 125 (113-162), 129 (100-145), and 112 (92-123) for the standard interface (p < .0001), respectively. The median (interquartile range) number of errors per provider was 0.5 (0-1) and two (0.25-3) for the novel user interface and standard electronic medical record interface, respectively (p = .007). A novel user interface was designed based on the information needs of intensive care unit providers with a specific goal of development being the reduction of task load and errors of cognition associated with filtering, extracting, and using medical data contained within a comprehensive electronic medical record. The results of this simulated clinical experiment suggest that the configuration of the intensive care unit user interface contributes significantly to the task load, time to task completion, and number of errors of cognition associated with the identification, and subsequent use, of relevant patient data. Task-specific user interfaces, developed from an understanding of provider information requirements, offer advantages over interfaces currently available within a standard electronic medical record.
Fieseler, Georg; Jungermann, Philipp; Koke, Alexander; Irlenbusch, Lars; Delank, Karl-Stefan; Schwesig, Rene
2015-03-01
Our objective was to investigate the influence of workload and consecutive changes on active range of motion and isometric strength of team handball athletes' throwing shoulders (TSs) because the available data are insufficient. In a longitudinal investigation, 31 professional male handball athletes underwent a clinical shoulder examination. Athletes were examined at the beginning (week 0), at the end (week 6) of the preseasonal training, and at the end of the half-season (week 22) on both shoulders to determine isometric rotational strength (hand held dynamometer) and active range of motion (goniometer). This analysis demonstrates the results subsequently from week 6 to week 22 and from week 0 to week 22. The glenohumeral internal rotation (IR) deficit (GIRD), external rotation (ER) gain, and ER at the TS increased significantly (P < .05, η(2) > 0.10, d > 0.30) in the first sequence (week 6 to week 22) but not significantly from week 0 to week 22. The total range of motion remained stable, and IR changed but not significantly. There was no influence on IR, ER, and total range of motion at the non-TS. The isometric strength of the TS and non-TS IR did not change. The isometric strength in ER significantly increased bilaterally during the investigation period. Our data verify changes and influences, such as an increasing GIRD, at the overhead TS joint in accordance with the workload during team handball season. ER gain did improve after the half-season period but did not fully compensate the GIRD at the TS. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Effects of insulin resistance on white matter microstructure in middle-aged and older adults
Coutu, Jean-Philippe; Rosas, H. Diana; Salat, David H.
2014-01-01
Objective: To investigate the potential relationship between insulin resistance (IR) and white matter (WM) microstructure using diffusion tensor imaging in cognitively healthy middle-aged and older adults. Methods: Diffusion tensor imaging was acquired from 127 individuals (age range 41–86 years). IR was evaluated by the homeostasis model assessment of IR (HOMA-IR). Participants were divided into 2 groups based on HOMA-IR values: “high HOMA-IR” (≥2.5, n = 27) and “low HOMA-IR” (<2.5, n = 100). Cross-sectional voxel-based comparisons were performed using Tract-Based Spatial Statistics and anatomically defined regions of interest analysis. Results: The high HOMA-IR group demonstrated decreased axial diffusivity broadly throughout the cerebral WM in areas such as the corpus callosum, corona radiata, cerebral peduncle, posterior thalamic radiation, and right superior longitudinal fasciculus, and WM underlying the frontal, parietal, and temporal lobes, as well as decreased fractional anisotropy in the body and genu of corpus callosum and parts of the superior and anterior corona radiata, compared with the low HOMA-IR group, independent of age, WM signal abnormality volume, and antihypertensive medication status. These regions additionally demonstrated linear associations between diffusion measures and HOMA-IR across all subjects, with higher HOMA-IR values being correlated with lower axial diffusivity. Conclusions: In generally healthy adults, greater IR is associated with alterations in WM tissue integrity. These cross-sectional findings suggest that IR contributes to WM microstructural alterations in middle-aged and older adults. PMID:24771537
Heinrich, Hannah T M; Bremer, Phil J; Daughney, Christopher J; McQuillan, A James
2007-02-27
Acid-base functional groups at the surface of Anoxybacillus flavithermus (AF) were assigned from the modeling of batch titration data of bacterial suspensions and compared with those determined from in situ infrared spectroscopic titration analysis. The computer program FITMOD was used to generate a two-site Donnan model (site 1: pKa = 3.26, wet concn = 2.46 x 10(-4) mol g(-1); site 2: pKa = 6.12, wet concn = 6.55 x 10(-5) mol g(-1)), which was able to describe data for whole exponential phase cells from both batch acid-base titrations at 0.01 M ionic strength and electrophoretic mobility measurements over a range of different pH values and ionic strengths. In agreement with information on the composition of bacterial cell walls and a considerable body of modeling literature, site 1 of the model was assigned to carboxyl groups, and site 2 was assigned to amino groups. pH difference IR spectra acquired by in situ attenuated total reflection infrared (ATR-IR) spectroscopy confirmed the presence of carboxyl groups. The spectra appear to show a carboxyl pKa in the 3.3-4.0 range. Further peaks were assigned to phosphodiester groups, which deprotonated at slightly lower pH. The presence of amino groups could not be confirmed or discounted by IR spectroscopy, but a positively charged group corresponding to site 2 was implicated by electrophoretic mobility data. Carboxyl group speciation over a pH range of 2.3-10.3 at two different ionic strengths was further compared to modeling predictions. While model predictions were strongly influenced by the ionic strength change, pH difference IR data showed no significant change. This meant that modeling predictions agreed reasonably well with the IR data for 0.5 M ionic strength but not for 0.01 M ionic strength.
Fragile magnetic order in the honeycomb lattice Iridate Na2IrO3 revealed by magnetic impurity doping
NASA Astrophysics Data System (ADS)
Mehlawat, Kavita; Sharma, G.; Singh, Yogesh
2015-10-01
We report the structure, magnetic, and thermal property measurements on single-crystalline and polycrystalline samples of the Ru-substituted honeycomb lattice iridate Na2Ir1 -xRuxO3 (x =0 ,0.05 ,0.1 ,0.15 ,0.2 ,0.3 ,0.5 ) . The evolution of magnetism in Na2Ir1 -xRuxO3 has been studied using dc and ac magnetic susceptibilities and heat-capacity measurements. The parent compound Na2IrO3 is a spin-orbit-driven Mott insulator with magnetic order of reduced moments below TN=15 K . In the Ru-substituted samples the antiferromagnetic long-range state is replaced by a spin-glass-like state even for the smallest substitution suggesting that the magnetic order in Na2IrO3 is extremely fragile. We argue that these behaviors indicate the importance of nearest-neighbor magnetic exchange in the parent Na2IrO3 . Additionally, all samples show insulating electrical transport.
NASA Astrophysics Data System (ADS)
Xiang, Li; Wang, Jingjuan; Zhang, Guijun; Rong, Lixin; Wu, Haozhong; Sun, Suqin; Guo, Yizhen; Yang, Yanfang; Lu, Lina; Qu, Lei
2016-11-01
Rhizoma Chuanxiong (CX) and Radix Angelica sinensis (DG) are very important Traditional Chinese Medicine (TCM) and usually used in clinic. They both are from the Umbelliferae family, and have almost similar chemical constituents with each other. It is complicated, time-consuming and laborious to discriminate them by using the chromatographic methods such as high performance liquid chromatography (HPLC) and gas chromatography (GC). Therefore, to find a fast, applicable and effective identification method for two herbs is urged in quality research of TCM. In this paper, by using a three-stage infrared spectroscopy (Fourier transform infrared spectroscopy (FT-IR), the second derivative infrared spectroscopy (SD-IR) and two-dimensional correlation infrared spectroscopy (2D-IR)), we analyzed and discriminated CX, DG and their different extracts (aqueous extract, alcoholic extract and petroleum ether extract). In FT-IR, all the CX and DG samples' spectra seemed similar, but they had their own unique macroscopic fingerprints to identify. Through comparing with the spectra of sucrose and the similarity calculation, we found the content of sucrose in DG raw materials was higher than in CX raw materials. The significant differences in alcoholic extract appeared that in CX alcoholic extract, the peaks at 1743 cm-1 was obviously stronger than the peak at same position in DG alcoholic extract. Besides in petroleum ether extract, we concluded CX contained much more ligustilide than DG by the similarity calculation. With the function of SD-IR, some tiny differences were amplified and overlapped peaks were also unfolded in FT-IR. In the range of 1100-1175 cm-1, there were six peaks in the SD-IR spectra of DG and the intensity, shape and location of those six peaks were similar to that of sucrose, while only two peaks could be observed in that of CX and those two peaks were totally different from sucrose in shape and relative intensity. This result was consistent with that of the FT-IR. Several undetected characteristic fingerprints in FT-IR and SD-IR spectra were further disclosed by 2D-IR spectra. In the range of 1120-1500 cm-1, the FT-IR spectra and the SD-IR spectra of aqueous extract of CX and DG were almost similar and hard to be discriminated, but the 2D-IR spectra were markedly different. These findings indicated that the three-stage infrared spectroscopy can identify not only the main compositions in these two medicinal materials and their different extracts, but also can compare the differences of categories and quantities of chemical constituents between the similar samples. In conclusion, the three-stage infrared spectroscopy could identify the two similar TCM (CX and DG) quickly and effectively.
Ultra-Low-Noise Sub-mm/Far-IR Detectors for Space-Based Telescopes
NASA Astrophysics Data System (ADS)
Rostem, Karwan
The sub-mm and Far-IR spectrum is rich with information from a wide range of astrophysical sources, including exoplanet atmospheres and galaxies at the peak star formation. In the 10-400 μm range, the spectral lines of important chemical species such H2O, HD, and [OI] can be used to map the formation and evolution of planetary systems. Dust emission in this spectral range is also an important tool for characterizing the morphology of debris disks and interstellar magnetic fields. At larger scales, accessing the formation and distribution of luminous Far-IR and sub-mm galaxies is essential to understanding star formation triggers, as well as the last stages of reionization at z 6. Detector technology is essential to realizing the full science potential of a next-generation Far-IR space telescope (Far-IR Surveyor). The technology gap in large-format, low-noise and ultra-low-noise Far-IR direct detectors is specifically highlighted by NASA's Cosmic Origins Program, and prioritized for development now to enable a flagship mission such as the Far-IR Surveyor that will address the key Cosmic Origins science questions of the next two decades. The detector requirements for a mid-resolution spectrometer are as follows: (1) Highly sensitive detectors with performance approaching 10^-19 - 10^-20 WHz 1/2 for background- limited operation in telescopes with cold optics. (2) Detector time constant in the sub- millisecond range. (3) Scalable architecture to a kilo pixel array with uniform detector characteristics. (4) Compatibility with space operation in the presence of particle radiation. We propose phononic crystals to meet the requirements of ultra-low-noise thermal detectors. By design, a phononic crystal exhibits phonon bandgaps where heat transport is forbidden. The size and location of the bandgaps depend on the elastic properties of the dielectric and the geometry of the phononic unit cell. A wide-bandwidth low-pass thermal filter with a cut-off frequency of 1.5 GHz and extending to 10 GHz can be realized with quasi-periodic phononic structures. A few 10^-19 WHz-1/2 detector sensitivity is readily accessible with phononic filter thermal isolation. Phononic filters are naturally compact, <20 μm in longest dimension, and contribute negligible heat capacity to a thermal sensor. We propose a three-year effort to fabricate and test phononic-isolated Transition- Edge Sensor arrays suitable for background-limited operation in a Far-IR Sur- veyor. We emphasize that phononic thermal isolation offers a viable path towards detector sensitivities an order of magnitude above that achieved with current state-of-the-art thermal detector technologies. Our effort addresses the APRA solicitation for advancing detector design and operation towards highly sensitive, compact, and robust characteristics.
NASA Technical Reports Server (NTRS)
Rujopakarn, W.; Rieke, G. H.; Papovich, C. J.; Weiner, B. J.; Rigby, Jane; Rex, M.; Bian, F.; Kuhn, O. P.; Thompson, D.
2012-01-01
We present spectroscopic observations in the rest-frame optical and near- to mid-infrared wavelengths of four gravitationally lensed infrared (IR) luminous star-forming galaxies at redshift 1 < z < 3 from the LUCIFER instrument on the Large Binocular Telescope and the Infrared Spectrograph on Spitzer. The sample was selected to represent pure, actively star-forming systems, absent of active galactic nuclei. The large lensing magnifications result in high signal-to-noise spectra that can probe faint IR recombination lines, including Paa and Bra at high redshifts. The sample was augmented by three lensed galaxies with similar suites of unpublished data and observations from the literature, resulting in the final sample of seven galaxies. We use the IR recombination lines in conjunction with Ha observations to probe the extinction, Av, of these systems, as well as testing star formation rate (SFR) indicators against the SFR measured by fitting spectral energy distributions to far-IR photometry. Our galaxies occupy a range of Av from 0 to 5.9 mag, larger than previously known for a similar range of IR luminosities at these redshifts. Thus, estimates of SFR even at z 2 must take careful count of extinction in the most IR luminous galaxies.We also measure extinction by comparing SFR estimates from optical emission lines with those from far- IR measurements. The comparison of results from these two independent methods indicates a large variety of dust distribution scenarios at 1 < z < 3. Without correcting for dust extinction, the Ha SFR indicator underestimates the SFR; the size of the necessary correction depends on the IR luminosity and dust distribution scenario. Individual SFR estimates based on the 6.2µm polycyclic aromatic hydrocarbon emission line luminosity do not show a systematic discrepancy with extinction, although a considerable, 0.2 dex, scatter is observed.
Benjamin, Sara E; Neelon, Brian; Ball, Sarah C; Bangdiwala, Shrikant I; Ammerman, Alice S; Ward, Dianne S
2007-01-01
Background Few assessment instruments have examined the nutrition and physical activity environments in child care, and none are self-administered. Given the emerging focus on child care settings as a target for intervention, a valid and reliable measure of the nutrition and physical activity environment is needed. Methods To measure inter-rater reliability, 59 child care center directors and 109 staff completed the self-assessment concurrently, but independently. Three weeks later, a repeat self-assessment was completed by a sub-sample of 38 directors to assess test-retest reliability. To assess criterion validity, a researcher-administered environmental assessment was conducted at 69 centers and was compared to a self-assessment completed by the director. A weighted kappa test statistic and percent agreement were calculated to assess agreement for each question on the self-assessment. Results For inter-rater reliability, kappa statistics ranged from 0.20 to 1.00 across all questions. Test-retest reliability of the self-assessment yielded kappa statistics that ranged from 0.07 to 1.00. The inter-quartile kappa statistic ranges for inter-rater and test-retest reliability were 0.45 to 0.63 and 0.27 to 0.45, respectively. When percent agreement was calculated, questions ranged from 52.6% to 100% for inter-rater reliability and 34.3% to 100% for test-retest reliability. Kappa statistics for validity ranged from -0.01 to 0.79, with an inter-quartile range of 0.08 to 0.34. Percent agreement for validity ranged from 12.9% to 93.7%. Conclusion This study provides estimates of criterion validity, inter-rater reliability and test-retest reliability for an environmental nutrition and physical activity self-assessment instrument for child care. Results indicate that the self-assessment is a stable and reasonably accurate instrument for use with child care interventions. We therefore recommend the Nutrition and Physical Activity Self-Assessment for Child Care (NAP SACC) instrument to researchers and practitioners interested in conducting healthy weight intervention in child care. However, a more robust, less subjective measure would be more appropriate for researchers seeking an outcome measure to assess intervention impact. PMID:17615078
NASA Technical Reports Server (NTRS)
Gruppioni, Carlotta; Pozzi, F.; Rodighiero, G.; Delvecchio, I.; Berta, S.; Pozzetti, L.; Zamorani, G.; Andreani, P.; Cimatti, A.; Ilbert, O.;
2013-01-01
We exploit the deep and extended far-IR data sets (at 70, 100 and 160 µm) of the Herschel Guaranteed Time Observation (GTO) PACS Evolutionary Probe (PEP) Survey, in combination with the Herschel Multi-tiered Extragalactic Survey data at 250, 350 and 500 µm, to derive the evolution of the rest-frame 35-, 60-, 90- and total infrared (IR) luminosity functions (LFs) up to z 4.We detect very strong luminosity evolution for the total IR LF (LIR ? (1 + z)(sup 3.55 +/- 0.10) up to z 2, and ? (1 + z)(sup 1.62 +/- 0.51) at 2 less than z less than approximately 4) combined with a density evolution (? (1 + z)(sup -0.57 +/- 0.22) up to z 1 and ? (1 + z)(sup -3.92 +/- 0.34) at 1 less than z less than approximately 4). In agreement with previous findings, the IR luminosity density (?IR) increases steeply to z 1, then flattens between z 1 and z 3 to decrease at z greater than approximately 3. Galaxies with different spectral energy distributions, masses and specific star formation rates (SFRs) evolve in very different ways and this large and deep statistical sample is the first one allowing us to separately study the different evolutionary behaviours of the individual IR populations contributing to ?IR. Galaxies occupying the well-established SFR-stellar mass main sequence (MS) are found to dominate both the total IR LF and ?IR at all redshifts, with the contribution from off-MS sources (=0.6 dex above MS) being nearly constant (20 per cent of the total ?IR) and showing no significant signs of increase with increasing z over the whole 0.8 < z <2.2 range. Sources with mass in the range 10 = log(M/solar mass) = 11 are found to dominate the total IR LF, with more massive galaxies prevailing at the bright end of the high-z (greater than approximately 2) LF. A two-fold evolutionary scheme for IR galaxies is envisaged: on the one hand, a starburst-dominated phase in which the Super Massive Black Holes (SMBH) grows and is obscured by dust (possibly triggered by a major merging event), is followed by an AGN-dominated phase, then evolving towards a local elliptical. On the other hand, moderately star-forming galaxies containing a low-luminosity AGN have various properties suggesting they are good candidates for systems in a transition phase preceding the formation of steady spiral galaxies.
NASA Astrophysics Data System (ADS)
Dermíšek, Radovan; McGinnis, Navin
2018-03-01
We use the IR fixed point predictions for gauge couplings and the top Yukawa coupling in the minimal supersymmetric model (MSSM) extended with vectorlike families to infer the scale of vectorlike matter and superpartners. We quote results for several extensions of the MSSM and present results in detail for the MSSM extended with one complete vectorlike family. We find that for a unified gauge coupling αG>0.3 vectorlike matter or superpartners are expected within 1.7 TeV (2.5 TeV) based on all three gauge couplings being simultaneously within 1.5% (5%) from observed values. This range extends to about 4 TeV for αG>0.2 . We also find that in the scenario with two additional large Yukawa couplings of vectorlike quarks the IR fixed point value of the top Yukawa coupling independently points to a multi-TeV range for vectorlike matter and superpartners. Assuming a universal value for all large Yukawa couplings at the grand unified theory scale, the measured top quark mass can be obtained from the IR fixed point for tan β ≃4 . The range expands to any tan β >3 for significant departures from the universality assumption. Considering that the Higgs boson mass also points to a multi-TeV range for superpartners in the MSSM, adding a complete vectorlike family at the same scale provides a compelling scenario where the values of gauge couplings and the top quark mass are understood as a consequence of the particle content of the model.
The infrared emission from the elliptical galaxy NGC 1052
NASA Technical Reports Server (NTRS)
Becklin, E. E.; Tokunaga, A. T.; Wynn-Williams, C. G.
1982-01-01
Multi-aperture IR photometry of the elliptical galaxy NGC 1052 shows that its IR excess is confined to a region smaller than 2 arc sec (300 pc) in diameter coincident with the visible nucleus. It is suggested that the emission in the 5-20 micron range arises from dust heated by the nonthermal source seen at other wavelengths.
FT-IR spectrum of grape seed oil and quantum models of fatty acids triglycerides
NASA Astrophysics Data System (ADS)
Berezin, K. V.; Antonova, E. M.; Shagautdinova, I. T.; Chernavina, M. L.; Dvoretskiy, K. N.; Grechukhina, O. N.; Vasilyeva, L. M.; Rybakov, A. V.; Likhter, A. M.
2018-04-01
FT-IR spectra of grape seed oil and glycerol were registered in the 650-4000 cm-1 range. Molecular models of glycerol and some fatty acids that compose the oil under study - linoleic, oleic, palmitic and stearic acids - as well as their triglycerides were developed within B3LYP/6-31G(d) density functional model. A vibrating FT-IR spectrum of grape seed oil was modeled on the basis of calculated values of vibrating wave numbers and IR intensities of the fatty acids triglycerides and with regard to their percentage. Triglyceride spectral bands that were formed by glycerol linkage vibrations were revealed. It was identified that triglycerol linkage has a small impact on the structure of fatty acids and, consequently, on vibrating wave numbers. The conducted molecular modeling became a basis for theoretical interpretation on 10 experimentally observed absorption bands in FT-IR spectrum of grape seed oil.
Yusuf, Imran H; Peirson, Stuart N; Patel, Chetan K
2012-03-01
To evaluate whether occlusive intraocular lenses (IOLs) produced by several manufacturers for clinical use equivalently transmit near-infrared (IR) light for scanning laser ophthalmoscopy (SLO) or optical coherence tomography (OCT) imaging. Nuffield Laboratory of Ophthalmology, Oxford University, United Kingdom. Evaluation of diagnostic test or technology. The study evaluated 6 black IOLs of 2 designs: 3 poly(methyl methacrylate) (PMMA) and 3 iris-claw anterior chamber IOLs. Each IOL was placed between a broad-spectrum white light source and a spectroradiometer to generate transmission spectra. Transmission in the near-IR range was examined using an 850 nm light-emitting diode. Scanning laser ophthalmoscopy or OCT imaging using Spectralis spectral-domain SLO or OCT was attempted through occlusive IOLs in a model eye. Artisan iris-claw and MS 612 PMMA occlusive IOLs totally occluded all wavelengths of light, including in the near IR range in which SLO and OCT imaging systems operate. It was not possible to capture SLO or OCT images through the iris-claw and PMMA occlusive IOLs in a model eye. Results suggest the property of near-IR transmission that permits SLO or OCT imaging through occlusive IOLs is restricted to the Morcher range of occlusive IOLs. Patients with non-near IR transmitting IOLs will not be able to receive detailed posterior segment monitoring with SLO or OCT. This finding may have a significant impact on preoperative occlusive IOL selection and the management of current patients with occlusive IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Layered chalcogenide glass structures for IR lenses
NASA Astrophysics Data System (ADS)
Gibson, Daniel; Bayya, Shyam; Sanghera, Jas; Nguyen, Vinh; Scribner, Dean; Maksimovic, Velimir; Gill, John; Yi, Allen; Deegan, John; Unger, Blair
2014-07-01
A technique for fabricating novel infrared (IR) lenses can enable a reduction in the size and weight of IR imaging optics through the use of layered glass structures. These structures can range from having a few thick glass layers, mimicking cemented doublets and triplets, to having many thin glass layers approximating graded index (GRIN) lenses. The effectiveness of these structures relies on having materials with diversity in refractive index (large Δn) and dispersion and similar thermo-viscous behavior (common glass transition temperature, ΔTg = 10°C). A library of 13 chalcogenide glasses with broad IR transmission (NIR through LWIR bands) was developed to satisfy these criteria. The lens fabrication methodology, including glass design and synthesis, sheet fabrication, preform making, lens molding and surface finishing are presented.
IRAS observations of young stellar objects in the Corona Australis dark cloud
NASA Technical Reports Server (NTRS)
Wilking, Bruce A.; Greene, Thomas P.; Lada, Charles J.; Meyer, Michael R.; Young, Erick T.
1992-01-01
The young stellar object (YSO) population associated with the dark cloud complex in Corona Australis is studied by synthesizing IRAS data with newly obtained near-IR and mid-IR photometry and previously published optical/IR data. Twenty-four YSOs in the Cr A complex are identified. The observed range of spectral energy distribution shapes and bolometric luminosities are consistent with those observed in other dark clouds. The duration and efficiency of star formation are found to be similar to the Rho Ophiuchi IR cluster. The low number of YSOs compared to other dark clouds is understood by a reevaluation of the molecular mass of the R Cr A cloud which shows it to be much less massive than previously assumed.
ACS experiment for atmospheric studies on "ExoMars-2016" Orbiter
NASA Astrophysics Data System (ADS)
Korablev, O. I.; Montmessin, F.; Fedorova, A. A.; Ignatiev, N. I.; Shakun, A. V.; Trokhimovskiy, A. V.; Grigoriev, A. V.; Anufreichik, K. A.; Kozlova, T. O.
2015-12-01
ACS is a set of spectrometers for atmospheric studies (Atmospheric Chemistry Suite). It is one of the Russian instruments for the Trace Gas Orbiter (TGO) of the Russian-European "ExoMars" program. The purpose of the experiment is to study the Martian atmosphere by means of two observations regimes: sensitive trace gases measurements in solar occultations and by monitoring the atmospheric state during nadir observations. The experiment will allow us to approach global problems of Mars research such as current volcanism, and the modern climate status and its evolution. Also, the experiment is intended to solve the mystery of methane presence in the Martian atmosphere. Spectrometers of the ACS set cover the spectral range from the near IR-range (0.7 μm) to the thermal IR-range (17 μm) with spectral resolution λ/Δλ reaching 50000. The ACS instrument consists of three independent IR spectrometers and an electronics module, all integrated in a single unit with common mechanical, electrical and thermal interfaces. The article gives an overview of scientific tasks and presents the concept of the experiment.
Wabitsch, Martin; Pridzun, Lutz; Ranke, Michael; von Schnurbein, Julia; Moss, Anja; Brandt, Stephanie; Kohlsdorf, Katja; Moepps, Barbara; Schaab, Michael; Funcke, Jan-Bernd; Gierschik, Peter; Fischer-Posovszky, Pamela; Flehmig, Bertram; Kratzsch, Jürgen
2017-03-01
Functional leptin deficiency is characterized by high levels of circulating immunoreactive leptin (irLep), but a reduced bioactivity of the hormone due to defective receptor binding. As a result of the fact that affected patients can be successfully treated with metreleptin, it was aimed to develop and validate a diagnostic tool to detect functional leptin deficiency. An immunoassay capable of recognizing the functionally relevant receptor-binding complex with leptin was developed (bioLep). The analytical quality of bioLep was validated and compared to a conventional assay for immune-reactive leptin (irLep). Its clinical relevance was evaluated in a cohort of lean and obese children and adults as well as in children diagnosed with functional leptin deficiency and their parents. In the clinical cohort, a bioLep/irLep ratio of 1.07 (range: 0.80-1.41) was observed. Serum of patients with non-functional leptin due to homozygous amino acid exchanges (D100Y or N103K) revealed high irLep but non-detectable bioLep levels. Upon treatment of these patients with metreleptin, irLep levels decreased, whereas levels of bioLep increased continuously. In patient relatives with heterozygous amino acid exchanges, a bioLep/irLep ratio of 0.52 (range: 0.48-0.55) being distinct from normal was observed. The new bioLep assay is able to diagnose impaired leptin bioactivity in severely obese patients with a homozygous gene defect and in heterozygous carriers of such mutations. The assay serves as a diagnostic tool to monitor leptin bioactivity during treatment of these patients. © 2017 The authors.
NASA Astrophysics Data System (ADS)
Klemenkova, Z. S.; Novskova, T. A.; Lyashchenko, A. K.
2008-04-01
The IR absorption spectra of aqueous solutions of dimethylsulfoxide (DMSO) with concentrations from 100% H2O to 100% DMSO were recorded over the frequency range 50-500 cm-1. The absorption spectra were described using the theoretical scheme of hindered rotators. A model was developed according to which orientation relaxation in solution was related to separate rotations of H2O and DMSO molecules through fixed small and (or) large angles in a unified network of H-bonds consisting of several subsystems ordered to various degrees. The calculated absorption spectra were in agreement with the experimental data in the far IR region. Elementary motions of molecules were found to slow down in the passage from pure dimethylsulfoxide to its aqueous solutions. The special features of the hydrophilic and hydrophobic hydration of DMSO polar and nonpolar groups were considered.
CHARMS: The Cryogenic, High-Accuracy Refraction Measuring System
NASA Technical Reports Server (NTRS)
Frey, Bradley; Leviton, Douglas
2004-01-01
The success of numerous upcoming NASA infrared (IR) missions will rely critically on accurate knowledge of the IR refractive indices of their constituent optical components at design operating temperatures. To satisfy the demand for such data, we have built a Cryogenic, High-Accuracy Refraction Measuring System (CHARMS), which, for typical 1R materials. can measure the index of refraction accurate to (+ or -) 5 x 10sup -3 . This versatile, one-of-a-kind facility can also measure refractive index over a wide range of wavelengths, from 0.105 um in the far-ultraviolet to 6 um in the IR, and over a wide range of temperatures, from 10 K to 100 degrees C, all with comparable accuracies. We first summarize the technical challenges we faced and engineering solutions we developed during the construction of CHARMS. Next we present our "first light," index of refraction data for fused silica and compare our data to previously published results.
Kandhro, Aftab A; Laghari, Abdul Hafeez; Mahesar, Sarfaraz A; Saleem, Rubina; Nelofar, Aisha; Khan, Salman Tariq; Sherazi, S T H
2013-11-01
A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887cm(-1). Excellent coefficient of determination (R(2)) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product. Copyright © 2013 Elsevier B.V. All rights reserved.
Analysis of in vitro interactions of protein tyrosine phosphatase 1B with insulin receptors.
Wang, X Y; Bergdahl, K; Heijbel, A; Liljebris, C; Bleasdale, J E
2001-02-28
One strategy to treat the insulin resistance that is central to type II diabetes mellitus may be to maintain insulin receptors (IR) in the active (tyrosine phosphorylated) form. Because protein tyrosine phosphatase 1B (PTP1B) binds and subsequently dephosphorylates IR, inhibitors of PTP1B-IR binding are potential insulin 'sensitizers.' A Scintillation Proximity Assay (SPA) was developed to characterize and quantitate PTP1B-IR binding. Human IR were solubilized and captured on wheat germ agglutinin (WGA)-coated SPA beads. Subsequent binding of human, catalytically inactive [35S] PTP1B Cys(215)/Ser (PTP1B(C215S)) to the lectin-anchored IR results in scintillation from the SPA beads that can be quantitated. Binding of PTP1B to IR was pH- and divalent cation-sensitive. Ca(2+) and Mn(2+), but not Mg(2+), dramatically attenuated the loss of PTP1B-IR binding observed when pH was raised from 6.2 to 7.8. PTP1B binding to IR from insulin-stimulated cells was much greater than to IR from unstimulated cells and was inhibited by either an antiphosphotyrosine antibody or treatment of IR with alkaline phosphatase, suggesting that tyrosine phosphorylation of IR is required for PTP1B binding. Phosphopeptides modeled after various IR phosphotyrosine domains each only partially inhibited PTP1B-IR binding, indicating that multiple domains of IR are likely involved in binding PTP1B. However, competitive displacement of [35S]PTP1B(C215S) by PTP1B(C215S) fitted best to a single binding site with a K(d) in the range 100-1000 nM, depending upon pH and divalent cations. PNU-200898, a potent and selective inhibitor of PTP1B whose orientation in the active site of PTP1B has been solved, competitively inhibited catalysis and PTP1B-IR binding with equal potency. The results of this novel assay for PTP1B-IR binding suggest that PTP1B binds preferentially to tyrosine phosphorylated IR through its active site and that binding may be susceptible to therapeutic disruption by small molecules.
Costs and cost-effectiveness of malaria control interventions - a systematic review
2011-01-01
Background The control and elimination of malaria requires expanded coverage of and access to effective malaria control interventions such as insecticide-treated nets (ITNs), indoor residual spraying (IRS), intermittent preventive treatment (IPT), diagnostic testing and appropriate treatment. Decisions on how to scale up the coverage of these interventions need to be based on evidence of programme effectiveness, equity and cost-effectiveness. Methods A systematic review of the published literature on the costs and cost-effectiveness of malaria interventions was undertaken. All costs and cost-effectiveness ratios were inflated to 2009 USD to allow comparison of the costs and benefits of several different interventions through various delivery channels, across different geographical regions and from varying costing perspectives. Results Fifty-five studies of the costs and forty three studies of the cost-effectiveness of malaria interventions were identified, 78% of which were undertaken in sub-Saharan Africa, 18% in Asia and 4% in South America. The median financial cost of protecting one person for one year was $2.20 (range $0.88-$9.54) for ITNs, $6.70 (range $2.22-$12.85) for IRS, $0.60 (range $0.48-$1.08) for IPT in infants, $4.03 (range $1.25-$11.80) for IPT in children, and $2.06 (range $0.47-$3.36) for IPT in pregnant women. The median financial cost of diagnosing a case of malaria was $4.32 (range $0.34-$9.34). The median financial cost of treating an episode of uncomplicated malaria was $5.84 (range $2.36-$23.65) and the median financial cost of treating an episode of severe malaria was $30.26 (range $15.64-$137.87). Economies of scale were observed in the implementation of ITNs, IRS and IPT, with lower unit costs reported in studies with larger numbers of beneficiaries. From a provider perspective, the median incremental cost effectiveness ratio per disability adjusted life year averted was $27 (range $8.15-$110) for ITNs, $143 (range $135-$150) for IRS, and $24 (range $1.08-$44.24) for IPT. Conclusions A transparent evidence base on the costs and cost-effectiveness of malaria control interventions is provided to inform rational resource allocation by donors and domestic health budgets and the selection of optimal packages of interventions by malaria control programmes. PMID:22050911
Management of adverse events related to new cancer immunotherapy (immune checkpoint inhibitors).
Bourke, Jack M; O'Sullivan, Michael; Khattak, Muhammad A
2016-11-07
New immunotherapies have significantly improved survival in certain advanced cancers in recent years, particularly metastatic melanoma and lung cancer. The most effective of these therapies are the immune checkpoint inhibitors (ICIs) such as ipilimumab, nivolumab and pembrolizumab. The use of ICIs will continue to increase in the coming years as evidence of their benefit in a range of other cancers builds. ICIs are associated with novel immune-related adverse events (irAEs), which can involve a wide range of organs. The most common irAEs involve the skin (rash, pruritus), gastrointestinal tract (diarrhoea, colitis) and endocrine system (thyroid, pituitary). While severity is generally mild, life-threatening complications can occur if not recognised and treated promptly. Due to the diverse manifestations of irAEs, patients may present to doctors who are not familiar with these drugs, which creates the potential for delays in management. Management of irAEs depends on severity and the organ affected. Systemic steroids are often required and ICI therapy may be withheld or discontinued. Additional immunosuppressive medications may be necessary in steroid-refractory cases. This review provides an overview of the potential toxicities and their management for general clinicians. Broader awareness of these issues among medical professionals will hopefully reduce unnecessary delays in diagnosis and treatment. Patient and carer education regarding irAEs is extremely important; patients and carers should be advised to seek urgent medical attention if required.
Mid infrared LHS system packaging using flexible waveguides
NASA Technical Reports Server (NTRS)
Yu, Chung
1987-01-01
As mid IR fiber optic systems are rapidly approaching a reality, so is the feasibility of fiber optic laser heterodyne systems. Laser heterodyne spectroscopy for high resolution monitoring of atmospheric gaseous pollutants is necessarily in the mid IR, the region in which the absorption signature of gaseous species is most prominent. It so happens that the lowest theoretical loss due to Rayleigh-Brillouin scattering also lies in the mid IR. Prospects of highly efficient laser heterodyne systems are thus very good. Such fibers are now beginning to be commercially available, and a test program is being conducted for such fibers with ambient temperature ranging from cryogenic to above room, and stringest mechanical flexibility requirements. Preliminary results are encouraging. A program is being started to explore the possibility of mid IR fiber optic device applications, by taking advantage of this phonon rich region. The potential long interaction length in fibers coupled with predicted extremely low losses point to stimulated Brillouin scattering based devices in the mW range. The generation of backscattered sBs at low laser powers is significant not only as an ultimate power limiting factor for laser transmission in fibers in the mid IR, but also the presence of frequency-shifted multiple order sBs Stokes and antiStokes lines will certainly have severe effect on the laser beats crucial in high resolution heterodyne spectroscopy.
Liu, Sibao; Simonetti, Trent; Zheng, Weiqing; Saha, Basudeb
2018-05-09
High yields of diesel-range alkanes are prepared by hydrodeoxygenation of vegetable oils and waste cooking oils over ReO x -modified Ir/SiO 2 catalysts under mild reaction conditions. The catalyst containing a Re/Ir molar ratio of 3 exhibits the best performance, achieving 79-85 wt % yield of diesel-range alkanes at 453 K and 2 MPa H 2 . The yield is nearly quantitative for the theoretical possible long-chain alkanes on the basis of weight of the converted oils. The catalyst retains comparable activity upon regeneration through calcination. Control experiments using probe molecules as model substrates suggest that C=C bonds of unsaturated triglycerides and free fatty acids are first hydrogenated to their corresponding saturated intermediates, which are then converted to aldehyde intermediates through hydrogenolysis of acyl C-O bonds and subsequently hydrogenated to fatty alcohols. Finally, long-chain alkanes without any carbon loss are formed by direct hydrogenolysis of the fatty alcohols. Small amounts of alkanes with one carbon fewer are also formed by decarbonylation of the aldehyde intermediates. A synergy between Ir and partially reduced ReO x sites is discussed to elucidate the high activity of Ir-ReO x /SiO 2. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Possible Mechanism of Infrared Radiation Reception: The Role of the Temperature Factor
NASA Astrophysics Data System (ADS)
Yachnev, I. L.; Penniyaynen, V. A.; Podzorova, S. A.; Rogachevskii, I. V.; Krylov, B. V.
2018-02-01
The role of the temperature factor in the mechanism of reception of the CO2 laser low-power infrared (IR) radiation (λ = 10.6 μm) by a sensory neuron membrane has been studied. Organotypic embryonic tissue culture has been used to measure and estimate the temperature of a sensory ganglia monolayer exposed to radiation at different energy densities. The effects of tissue exposure to low-power IR radiation have been investigated. It has been found that inhibition of tissue growth by radiation of low energy density (10-14-10-10 J/cm2) is replaced by tissue growth (10-7-10-4 J/cm2), and again followed by inhibition in the range of 0.1-6 J/cm2. A statistically significant specific reaction to nonthermal radiation has been detected at the radiation power density of 3 × 10-10 J/cm2, which is due to activation of the Na+,K+-ATPase transducer function. The mechanisms of interaction of IR radiation with embryonic nerve tissue have been considered. Low-power IR radiation with the wavelength of 10.6 μm has been demonstrated to specifically activate a novel signal transducer function of the sodium pump, which controls the reception of nonthermal IR radiation in the energy density range of 10-14 to 10-10 J/cm2.
Reaction mechanism for oxygen evolution on RuO 2, IrO 2, and RuO 2@IrO 2 core-shell nanocatalysts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Zhong; Zhang, Yu; Liu, Shizhong
Iridium dioxide, IrO 2, is second to the most active RuO 2 catalyst for the oxygen evolution reaction (OER) in acid, and is used in proton exchange membrane water electrolyzers due to its high durability. In order to improve the activity of IrO 2-based catalysts, we prepared RuO 2@IrO 2 core-shell nanocatalysts using carbon-supported Ru as the template. At 1.48 V, the OER specific activity of RuO 2@IrO 2 is threefold that of IrO 2. While the activity volcano plots over wide range of materials have been reported, zooming into the top region to clarify the rate limiting steps ofmore » most active catalysts is important for further activity enhancement. Here, we verified theory-proposed sequential water dissociation pathway in which the O—O bond forms on a single metal site, not via coupling of two adsorbed intermediates, by fitting measured polarization curves using a kinetic equation with the free energies of adsorption and activation as the parameters. Consistent with theoretical calculations, we show that the OER activities of IrO 2 and RuO 2@IrO 2 are limited by the formation of O adsorbed phase, while the OOH formation on the adsorbed O limits the reaction rate on RuO 2.« less
Reaction mechanism for oxygen evolution on RuO 2, IrO 2, and RuO 2@IrO 2 core-shell nanocatalysts
Ma, Zhong; Zhang, Yu; Liu, Shizhong; ...
2017-10-28
Iridium dioxide, IrO 2, is second to the most active RuO 2 catalyst for the oxygen evolution reaction (OER) in acid, and is used in proton exchange membrane water electrolyzers due to its high durability. In order to improve the activity of IrO 2-based catalysts, we prepared RuO 2@IrO 2 core-shell nanocatalysts using carbon-supported Ru as the template. At 1.48 V, the OER specific activity of RuO 2@IrO 2 is threefold that of IrO 2. While the activity volcano plots over wide range of materials have been reported, zooming into the top region to clarify the rate limiting steps ofmore » most active catalysts is important for further activity enhancement. Here, we verified theory-proposed sequential water dissociation pathway in which the O—O bond forms on a single metal site, not via coupling of two adsorbed intermediates, by fitting measured polarization curves using a kinetic equation with the free energies of adsorption and activation as the parameters. Consistent with theoretical calculations, we show that the OER activities of IrO 2 and RuO 2@IrO 2 are limited by the formation of O adsorbed phase, while the OOH formation on the adsorbed O limits the reaction rate on RuO 2.« less
Cerný, Radovan; Renaudin, Guillaume; Favre-Nicolin, Vincent; Hlukhyy, Viktor; Pöttgen, Rainer
2004-06-01
The new binary compound Mg(1 + x)Ir(1 - x) (x = 0-0.054) was prepared by melting the elements in the Mg:Ir ratio 2:3 in a sealed tantalum tube under an argon atmosphere in an induction furnace (single crystals) or by annealing cold-pressed pellets of the starting composition Mg:Ir 1:1 in an autoclave under an argon atmosphere (powder sample). The structure was independently solved from high-resolution synchrotron powder and single-crystal X-ray data: Pearson symbol oC304, space group Cmca, lattice parameters from synchrotron powder data a = 18.46948 (6), b = 16.17450 (5), c = 16.82131 (5) A. Mg(1 + x)Ir(1 - x) is a topologically close-packed phase, containing 13 Ir and 12 Mg atoms in the asymmetric unit, and has a narrow homogeneity range. Nearly all the atoms have Frank-Kasper-related coordination polyhedra, with the exception of two Ir atoms, and this compound contains the shortest Ir-Ir distances ever observed. The solution of a rather complex crystal structure from powder diffraction, which was fully confirmed by the single-crystal method, shows the power of powder diffraction in combination with the high-resolution data and the global optimization method.
The Scope Of Fourier Transform Infrared (FTIR)
NASA Astrophysics Data System (ADS)
Hirschfeld, T.
1981-10-01
Three auarters of a century after its inception, a generation after its advantages were recognized, and a decade after its first commercialization, FT-IR dominates the growth of the IR market, and reigns alone over its high performance end. What lies ahead for FT-IR now? On one hand, the boundary between it and the classical scanning spectrometers is becoming fuzzy, as gratings attempt to use as much of FT-IR's computer technology as they can handle, and smaller FT systems invade the medium cost instrument range. On the other hand, technology advances in IR detectors, non-Fourier interference devices, and the often announced tunable laser are at long last getting set to make serious inroads in the field (although not necessarily in the manner most of us expected). However, the dominance of FT-IR as the leading edge of IR spectroscopy seems assured for a good many years. The evolution of FT-IR will be dominated by demands not yet fully satisfied such as rapid sample turnover, better quantitation, automated interpretation, higher GC-IR sensitivity, improved LC-IR, and, above all else, reliability and ease of use. These developments will be based on multiple small advances in hardware, large advances in the way systems are put together, and the traditional yearly revolutionary advances of the computer industry. The big question in the field will, however, still be whether our ambition and our skill can continue to keep up with the advances of our tools. It will be fun.
You, Youngmin; Nam, Wonwoo
2012-11-07
The development of cyclometalated Ir(III) complexes has enabled important breakthroughs in electroluminescence because such complexes permit the efficient population of triplet excited states that give rise to luminescent transitions. The triplet states of Ir(III) complexes are advantageous over those of other transition metal complexes in that their electronic transitions and charge-transfer characteristics are tunable over wide ranges. These favorable properties suggest that Ir(III) complexes have significant potential in a variety of photofunctions other than electroluminescence. In this critical review, we describe recent photonic applications of novel Ir(III) complexes. Ir(III) complexes have been shown to affect the exciton statistics in the active layers of organic photovoltaic cells, thereby improving the photon-to-current conversion efficiencies. Nonlinear optical applications that take advantage of the strong charge-transfer properties of triplet transitions are also discussed. The tunability of the electrochemical potentials facilitates the development of efficient photocatalysis in the context of water photolysis or organic syntheses. The photoredox reactivities of Ir(III) complexes have been employed in studies of charge migration along DNA chains. The photoinduced cytotoxicity of Ir(III) complexes on live cells suggests that the complexes may be useful in photodynamic therapy. Potential biological applications of the complexes include phosphorescence labeling and sensing. Intriguing platforms based on cyclometalated Ir(III) complexes potentially provide novel protein tagging and ratiometric detection. We envision that future research into the photofunctionality of Ir(III) complexes will provide important breakthroughs in a variety of photonic applications.
Sturrock, H.; Hsiang, M.; Roberts, K.; Kleinschmidt, I.; Nghipumbwa, M.; Uusiku, P.; Smith, J.; Bennet, A.; Kizito, W.; Takarinda, K.; Ade, S.; Gosling, R.
2018-01-01
Setting: A comparison of routine Namibia National Malaria Programme data (reported) vs. household survey data (administrative) on indoor residual spraying (IRS) in western Zambezi region, Namibia, for the 2014–2015 malaria season. Objectives: To determine 1) IRS coverage (administrative and reported), 2) its effect on malaria incidence, and 3) reasons for non-uptake of IRS in western Zambezi region, Namibia, for the 2014–2015 malaria season. Design: This was a descriptive study. Results: IRS coverage in western Zambezi region was low, ranging from 42.3% to 52.2% for administrative coverage vs. 45.9–66.7% for reported coverage. There was no significant correlation between IRS coverage and malaria incidence for this region (r = −0.45, P = 0.22). The main reasons for households not being sprayed were that residents were not at home during spraying times or that spray operators did not visit the households. Conclusions: IRS coverage in western Zambezi region, Namibia, was low during the 2014–2015 malaria season because of poor community engagement and awareness of times for spray operations within communities. Higher IRS coverage could be achieved through improved community engagement. Better targeting of the highest risk areas by the use of malaria surveillance will be required to mitigate malaria transmission. PMID:29713594
Mumbengegwi, D R; Sturrock, H; Hsiang, M; Roberts, K; Kleinschmidt, I; Nghipumbwa, M; Uusiku, P; Smith, J; Bennet, A; Kizito, W; Takarinda, K; Ade, S; Gosling, R
2018-04-25
Setting: A comparison of routine Namibia National Malaria Programme data (reported) vs. household survey data (administrative) on indoor residual spraying (IRS) in western Zambezi region, Namibia, for the 2014-2015 malaria season. Objectives: To determine 1) IRS coverage (administrative and reported), 2) its effect on malaria incidence, and 3) reasons for non-uptake of IRS in western Zambezi region, Namibia, for the 2014-2015 malaria season. Design: This was a descriptive study. Results: IRS coverage in western Zambezi region was low, ranging from 42.3% to 52.2% for administrative coverage vs. 45.9-66.7% for reported coverage. There was no significant correlation between IRS coverage and malaria incidence for this region ( r = -0.45, P = 0.22). The main reasons for households not being sprayed were that residents were not at home during spraying times or that spray operators did not visit the households. Conclusions: IRS coverage in western Zambezi region, Namibia, was low during the 2014-2015 malaria season because of poor community engagement and awareness of times for spray operations within communities. Higher IRS coverage could be achieved through improved community engagement. Better targeting of the highest risk areas by the use of malaria surveillance will be required to mitigate malaria transmission.
Sun, Jifu; Wu, Wanhua; Zhao, Jianzhang
2012-06-25
Cyclometalated Ir(III) complexes with acetylide ppy and bpy ligands were prepared (ppy = 2-phenylpyridine, bpy = 2,2'-bipyridine) in which naphthal (Ir-2) and naphthalimide (NI) were attached onto the ppy (Ir-3) and bpy ligands (Ir-4) through acetylide bonds. [Ir(ppy)(3)] (Ir-1) was also prepared as a model complex. Room-temperature phosphorescence was observed for the complexes; both neutral and cationic complexes Ir-3 and Ir-4 showed strong absorption in the visible range (ε=39,600 M(-1) cm(-1) at 402 nm and ε=25,100 M(-1) cm(-1) at 404 nm, respectively), long-lived triplet excited states (τ(T)=9.30 μs and 16.45 μs) and room-temperature red emission (λ(em)=640 nm, Φ(p)=1.4 % and λ(em)=627 nm, Φ(p)=0.3 %; cf. Ir-1: ε=16,600 M(-1) cm(-1) at 382 nm, τ(em)=1.16 μs, Φ(p)=72.6 %). Ir-3 was strongly phosphorescent in non-polar solvent (i.e., toluene), but the emission was completely quenched in polar solvents (MeCN). Ir-4 gave an opposite response to the solvent polarity, that is, stronger phosphorescence in polar solvents than in non-polar solvents. Emission of Ir-1 and Ir-2 was not solvent-polarity-dependent. The T(1) excited states of Ir-2, Ir-3, and Ir-4 were identified as mainly intraligand triplet excited states ((3)IL) by their small thermally induced Stokes shifts (ΔE(s)), nanosecond time-resolved transient difference absorption spectroscopy, and spin-density analysis. The complexes were used as triplet photosensitizers for triplet-triplet annihilation (TTA) upconversion and quantum yields of 7.1 % and 14.4 % were observed for Ir-2 and Ir-3, respectively, whereas the upconversion was negligible for Ir-1 and Ir-4. These results will be useful for designing visible-light-harvesting transition-metal complexes and for their applications as triplet photosensitizers for photocatalysis, photovoltaics, TTA upconversion, etc. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lead Apron Inspection Using Infrared Light: A Model Validation Study.
McKenney, Sarah E; Otero, Hansel J; Fricke, Stanley T
2018-02-01
To evaluate defect detection in radiation protective apparel, typically called lead aprons, using infrared (IR) thermal imaging. The use of IR lighting eliminates the need for access to x-ray-emitting equipment and radiation dose to the inspector. The performance of radiation workers was prospectively assessed using both a tactile inspection and the IR inspection with a lead apron phantom over a 2-month period. The phantom was a modified lead apron with a series of nine holes of increasing diameter ranging from 2 to 35 mm in accordance with typical rejection criteria. Using the tactile method, a radiation worker would feel for the defects in the lead apron. For the IR inspection, a 250-W IR light source was used to illuminate the lead apron phantom; an IR camera detected the transmitted radiation. The radiation workers evaluated two stills from the IR camera. From the 31 participants inspecting the lead apron phantom with the tactile method, only 2 participants (6%) correctly discovered all 9 holes and 1 participant reported a defect that was not there; 10 of the 20 participants (50%) correctly identified all 9 holes using the IR method. Using a weighted average, 5.4 defects were detected with the tactile method and 7.5 defects were detected with the IR method. IR light can penetrate an apron's protective outer fabric and illuminate defects below the current standard rejection size criteria. The IR method improves defect detectability as compared with the tactile method. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Eisler, K.; Goldammer, M.; Rothenfusser, M.; Arnold, W.; Homma, C.
2012-05-01
The spectral selective thermography with infrared filters can be used to determine or to distinguish materials such as contaminations on a metallic component. With additional visual information, the indications by the IR signal can be selectively accentuated or suppressed for easier evaluation of passive and active thermography measurements. For flash thermography the detected IR signal between 3.4 and 5.1 μm is analyzed with regard to the spectral material information. The presented hybrid camera uses beam overlapping to obtain combined images of both in the infrared and the visual range.
Air Pollution and Ischemic Stroke Among Young Adults.
Yitshak Sade, Maayan; Novack, Victor; Ifergane, Gal; Horev, Anat; Kloog, Itai
2015-12-01
Studies have demonstrated consistent associations between cardiovascular illness and particulate matter (PM) <10 and <2.5 μm in diameter, but stroke received less attention. We hypothesized that air pollution, an inflammation progenitor, can be associated with stroke incidence in young patients in whom the usual risk factors for stroke are less prevalent. We aimed to evaluate the association between stroke incidence and exposure to PM <10 and <2.5 μm, in a desert area characterized by a wide range of PM. We included all members of the largest health maintenance organization in Israel, who were admitted to a local hospital with stroke between 2005 and 2012. Exposure assessment was based on a hybrid model incorporating daily satellite remote sensing data at 1-km spatial resolution. We performed case-crossover analysis, stratified by personal characteristics and distance from main roads. We identified 4837 stroke cases (89.4% ischemic stroke). Interquartile range of PM <10 and <2.5 μm was 36.3 to 54.7 and 16.7 to 23.3 μg/m(3), respectively. The subjects' average age was 70 years; 53.4% were males. Associations between ischemic stroke and increases of interquartile range average concentrations of particulate matter <10 or <2.5 μm at the day of the event were observed among subjects <55 years (odds ratio [95% confidence interval], 1.11 [1.02-1.20] and 1.10 [1.00-1.21]). Stronger associations were observed in subjects living within 75 m from a main road (1.22 [1.03-1.43] and 1.26 [1.04-1.51]). We observed higher risk for ischemic stroke associated with PM among young adults. This finding can be explained by the inflammatory mechanism, linking air pollution and stroke. © 2015 American Heart Association, Inc.
Borghol-Kassar, R; Menezo-Rozalén, J L; Harto-Castaño, M A; Desco-Esteban, M C
2015-03-01
The aim of this article is to study the effect of unilateral congenital cataract surgery on ocular growth and corneal flattening. This is a cross-sectional study of 59 patients operated on due to a unilateral congenital cataract. The median age of the patients at the time of diagnosis was 17 months (interquartile range, 5-39 months). The median age at cataract the time of surgery was 28 months (interquartile range, 8-52 months), and the mean follow-up between cataract surgery and assessments was 149.7±69.9 months (range, 30-319 months). Axial length and corneal curvature were measured in both operated and non-operated eyes, comparing the results between them. There were no statistically significant differences for axial length growth or corneal flattening between operated and non-operated eyes: axial length (P=.327, Student t test) and corneal curvature (P=.078, Student t test). A sub-analysis was performed using the visual acuity and the age of the patient at the time of surgery. The only statistically significant data (P=.007, Student t test) was a lower axial length in operated eyes compared to non-operated eyes, in the non-deep-amblyopia group. No significant axial length growth modifications were observed between operated and non-operated eyes. Only the non-deep-amblyopia group presented with a lower axial length in the operated eyes compared to non-operated eyes. No significant differences in corneal flattening were found between groups after unilateral congenital cataract surgery. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Litton, Edward; Elliott, Rosalind; Thompson, Kelly; Watts, Nicola; Seppelt, Ian; Webb, Steven A R
2017-06-01
To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs. A cross-sectional, observational study. Australian and New Zealand ICUs. All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015. Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight. The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79-83) versus 77 dB (95% CI, 77-78), mean difference 4 dB (95% CI, 0-2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1-4) and three (interquartile range, 2-5), respectively. Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.
The operative outcomes of displaced medial-end clavicle fractures.
Sidhu, Verinder S; Hermans, Deborah; Duckworth, David G
2015-11-01
Nonoperative treatment of displaced medial clavicle fractures often leads to poor functional outcomes and painful nonunions. This study investigates the functional outcomes of patients undergoing operative fixation of these fractures. We investigated 27 patients undergoing operative fixation of a medial clavicle fracture; 24 had an acute, displaced fracture and 3 had fixation for nonunions. Preoperative radiographs or computed tomography scans were obtained, and data collected included age, sex, mechanism of injury, and fixation method. Follow-up included physical examination and radiographs for assessment of union; Disabilities of the Arm, Shoulder, and Hand scores at 12 months; and the recording of complications. The median age was 37 years (interquartile range, 17-47 years). There were 26 male patients and one female patient included, with 7 physeal injuries and 20 adult injuries. The most common mechanism of fracture was vehicular accident (n = 15). Three patients had operations for nonunions and 2 for a periprosthetic fracture medial to an existing plate. The fracture was fixed with plate and screws in 19 cases and with transosseous sutures in 8 cases. The median Disabilities of the Arm, Shoulder, and Hand score at 12 months was 0.4 (interquartile range, 0-5.0), with a union rate of 100% at 12 months. All patients had full shoulder range of motion at final follow-up and were able to return to preinjury occupational activities. There were no significant complications. Operative fixation of displaced medial clavicle fractures results in anatomic reconstruction and excellent functional outcomes, even in the setting of fixation performed for symptomatic nonunion. Early intervention can minimize the risk of painful nonunion. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Evaluating galactic habitability using high-resolution cosmological simulations of galaxy formation
NASA Astrophysics Data System (ADS)
Forgan, Duncan; Dayal, Pratika; Cockell, Charles; Libeskind, Noam
2017-01-01
We present the first model that couples high-resolution simulations of the formation of local group galaxies with calculations of the galactic habitable zone (GHZ), a region of space which has sufficient metallicity to form terrestrial planets without being subject to hazardous radiation. These simulations allow us to make substantial progress in mapping out the asymmetric three-dimensional GHZ and its time evolution for the Milky Way (MW) and Triangulum (M33) galaxies, as opposed to works that generally assume an azimuthally symmetric GHZ. Applying typical habitability metrics to MW and M33, we find that while a large number of habitable planets exist as close as a few kiloparsecs from the galactic centre, the probability of individual planetary systems being habitable rises as one approaches the edge of the stellar disc. Tidal streams and satellite galaxies also appear to be fertile grounds for habitable planet formation. In short, we find that both galaxies arrive at similar GHZs by different evolutionary paths, as measured by the first and third quartiles of surviving biospheres. For the MW, this interquartile range begins as a narrow band at large radii, expanding to encompass much of the Galaxy at intermediate times before settling at a range of 2-13 kpc. In the case of M33, the opposite behaviour occurs - the initial and final interquartile ranges are quite similar, showing gradual evolution. This suggests that Galaxy assembly history strongly influences the time evolution of the GHZ, which will affect the relative time lag between biospheres in different galactic locations. We end by noting the caveats involved in such studies and demonstrate that high-resolution cosmological simulations will play a vital role in understanding habitability on galactic scales, provided that these simulations accurately resolve chemical evolution.
Thomsen, Felix Sebastian Leo; Delrieux, Claudio Augusto; de Luis-García, Rodrigo
2017-03-01
Descriptors extracted from magnetic resonance imaging (MRI) of the brain can be employed to locate and characterize a wide range of pathologies. Scalar measures are typically derived within a single-voxel unit, but neighborhood-based texture measures can also be applied. In this work, we propose a new set of descriptors to compute local texture characteristics from scalar measures of diffusion tensor imaging (DTI), such as mean and radial diffusivity, and fractional anisotropy. We employ weighted rotational invariant local operators, namely standard deviation, inter-quartile range, coefficient of variation, quartile coefficient of variation and skewness. Sensitivity and specificity of those texture descriptors were analyzed with tract-based spatial statistics of the white matter on a diffusion MRI group study of elderly healthy controls, patients with mild cognitive impairment (MCI), and mild or moderate Alzheimer's disease (AD). In addition, robustness against noise has been assessed with a realistic diffusion-weighted imaging phantom and the contamination of the local neighborhood with gray matter has been measured. The new texture operators showed an increased ability for finding formerly undetected differences between groups compared to conventional DTI methods. In particular, the coefficient of variation, quartile coefficient of variation, standard deviation and inter-quartile range of the mean and radial diffusivity detected significant differences even between previously not significantly discernible groups, such as MCI versus moderate AD and mild versus moderate AD. The analysis provided evidence of low contamination of the local neighborhood with gray matter and high robustness against noise. The local operators applied here enhance the identification and localization of areas of the brain where cognitive impairment takes place and thus indicate them as promising extensions in diffusion MRI group studies.
Mehta, Amar J; Kubzansky, Laura D; Coull, Brent A; Kloog, Itai; Koutrakis, Petros; Sparrow, David; Spiro, Avron; Vokonas, Pantel; Schwartz, Joel
2015-01-27
There is mixed evidence suggesting that air pollution may be associated with increased risk of developing psychiatric disorders. We aimed to investigate the association between air pollution and non-specific perceived stress, often a precursor to development of affective psychiatric disorders. This longitudinal analysis consisted of 987 older men participating in at least one visit for the Veterans Administration Normative Aging Study between 1995 and 2007 (n = 2,244 visits). At each visit, participants were administered the 14-item Perceived Stress Scale (PSS), which quantifies stress experienced in the previous week. Scores ranged from 0-56 with higher scores indicating increased stress. Differences in PSS score per interquartile range increase in moving average (1, 2, and 4-weeks) of air pollution exposures were estimated using linear mixed-effects regression after adjustment for age, race, education, physical activity, anti-depressant medication use, seasonality, meteorology, and day of week. We also evaluated effect modification by season (April-September and March-October for warm and cold season, respectively). Fine particles (PM2.5), black carbon (BC), nitrogen dioxide, and particle number counts (PNC) at moving averages of 1, 2, and 4-weeks were associated with higher perceived stress ratings. The strongest associations were observed for PNC; for example, a 15,997 counts/cm(3) interquartile range increase in 1-week average PNC was associated with a 3.2 point (95%CI: 2.1-4.3) increase in PSS score. Season modified the associations for specific pollutants; higher PSS scores in association with PM2.5, BC, and sulfate were observed mainly in colder months. Air pollution was associated with higher levels of perceived stress in this sample of older men, particularly in colder months for specific pollutants.
Beng Leong, Lim; Wei Ming, Ng; Wei Feng, Lee
2018-06-19
We reviewed the use of noninvasive ventilation (NIV) versus high flow nasal cannula (HFNC) oxygen in adult acute respiratory failure (ARF). We searched major databases and included randomized trials comparing at least NIV with HFNC or NIV+HFNC with NIV in ARF. Primary outcomes included intubation/re-intubation rates. Secondary outcomes were ICU mortality and morbidities. Five trials were included; three compared HFNC with NIV, one compared HFNC, NIV and oxygen whereas one compared HFNC+NIV with NIV. Patients had hypoxaemic ARF (PaO2/FiO2≤300 mmHg). Heterogeneity prevented result pooling. Three and two studies had superiority and noninferiority design, respectively. Patients were postcardiothoracic surgery, mixed medical/surgical patients and those with pneumonia. Two trials were conducted after extubation, two before intubation and one during intubation. Three trials reported intubation/re-intubation rates as the primary outcomes. The other two trials reported the lowest peripheral capillary oxygen saturation readings during bronchoscopy or intubation. In the former three trials, the odds ratio for intubation/re-intubation rates between HFNC versus the NIV group ranged from 0.80 (95% confidence interval: 0.54-1.19) to 1.65 (95% confidence interval: 0.96-2.84). In the latter two trials, only one reported a difference in the lowest peripheral capillary oxygen saturation between NIV+HFNC versus the NIV group during intubation [100% (interquartile range: 95-100) vs. 96% (interquartile range: 92-99); P=0.029]. The secondary outcomes included differences in ICU mortality and patient tolerability, favouring HFNC, were conflicting, but highlighted future research directions. These include patients with hypercapneic ARF, more severe hypoxaemia (PaO2/FiO2≤200 mmHg), a superiority design, an oxygen arm and patient-centred outcomes.
Al-Tamimi, Yahia Z; Helmy, Adel; Bavetta, Seb; Price, Stephen J
2009-01-01
Intraparenchymal monitoring devices play an important role in the daily management of head injury and other critically ill neurosurgical patients. Although zero drift data exist for the Camino system (Camino Laboratories, San Diego, CA), only in vitro data exist for the Codman system (Codman and Shurtleff, Inc., Raynham, MA). The aim of this study was to assess the extent of zero drift for the Codman intracranial pressure (ICP) monitor in patients being monitored in 2 neurointensive care units. This was a prospective study conducted at 2 neurointensive care units. Eighty-eight patients who required ICP monitoring and who presented to the 2 neurosurgical departments, Center 1 (n = 48) and Center 2 (n = 40), were recruited for participation. The duration of ICP monitoring was noted, as was the resultant pressure reading in normal saline on removing the ICP monitor (zero drift). The median absolute zero drift for the group was 2.0 mm Hg (interquartile range, 1-3 mm Hg). The median time in situ was 108 hours (interquartile range, 69-201 hours). There was a positive correlation between the drift and time of the probe spent in situ (Spearman's correlation coefficient = 0.342; P = 0.001). Of the readings, 20 and 2% showed a drift greater than 5 and 10 mm Hg in magnitude, respectively. These data demonstrate that a small amount of zero drift exists in ICP monitors and that this drift increases with time. The wide range in the data demonstrates that some drift readings are quite excessive. This reinforces the school of thought that, although ICP readings contribute significantly to the management of neurosurgical patients, they should be interpreted carefully and in conjunction with clinical and radiological assessment of patients.
Zhang, Lihua; Desai, Nihar R; Li, Jing; Hu, Shuang; Wang, Qing; Li, Xi; Masoudi, Frederick A; Spertus, John A; Nuti, Sudhakar V; Wang, Sisi; Krumholz, Harlan M; Jiang, Lixin
2015-01-01
Background Early clopidogrel administration to patients with acute myocardial infarction (AMI) has been demonstrated to improve outcomes in a large Chinese trial. However, patterns of use of clopidogrel for patients with AMI in China are unknown. Methods and Results From a nationally representative sample of AMI patients from 2006 and 2011, we identified 11 944 eligible patients for clopidogrel therapy and measured early clopidogrel use, defined as initiation within 24 hours of hospital admission. Among the patients eligible for clopidogrel, the weighted rate of early clopidogrel therapy increased from 45.7% in 2006 to 79.8% in 2011 (P<0.001). In 2006 and 2011, there was significant variation in early clopidogrel use by region, ranging from 1.5% to 58.0% in 2006 (P<0.001) and 48.7% to 87.7% in 2011 (P<0.001). While early use of clopidogrel was uniformly high in urban hospitals in 2011 (median 89.3%; interquartile range: 80.1% to 94.5%), there was marked heterogeneity among rural hospitals (median 50.0%; interquartile range: 11.5% to 84.4%). Patients without reperfusion therapy and those admitted to rural hospitals were less likely to be treated with clopidogrel. Conclusions Although the use of early clopidogrel therapy in patients with AMI has increased substantially in China, there is notable wide variation across hospitals, with much less adoption in rural hospitals. Quality improvement initiatives are needed to increase consistency of early clopidogrel use for patients with AMI. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier: NCT01624883. PMID:26163041
Vanhommerig, Joost W; Bezemer, Daniela; Molenkamp, Richard; Van Sighem, Ard I; Smit, Colette; Arends, Joop E; Lauw, Fanny N; Brinkman, Kees; Rijnders, Bart J; Newsum, Astrid M; Bruisten, Sylvia M; Prins, Maria; Van Der Meer, Jan T; Van De Laar, Thijs J; Schinkel, Janke
2017-09-24
MSM are at increased risk for infection with HIV-1 and hepatitis C virus (HCV). Is HIV/HCV coinfection confined to specific HIV transmission networks? A HIV phylogenetic tree was constructed for 5038 HIV-1 subtype B polymerase (pol) sequences obtained from MSM in the AIDS therapy evaluation in the Netherlands cohort. We investigated the existence of HIV clusters with increased HCV prevalence, the HIV phylogenetic density (i.e. the number of potential HIV transmission partners) of HIV/HCV-coinfected MSM compared with HIV-infected MSM without HCV, and the overlap in HIV and HCV phylogenies using HCV nonstructural protein 5B sequences from 183 HIV-infected MSM with acute HCV infection. Five hundred and sixty-three of 5038 (11.2%) HIV-infected MSM tested HCV positive. Phylogenetic analysis revealed 93 large HIV clusters (≥10 MSM), 370 small HIV clusters (2-9 MSM), and 867 singletons with a median HCV prevalence of 11.5, 11.6, and 9.3%, respectively. We identified six large HIV clusters with elevated HCV prevalence (range 23.5-46.2%). Median HIV phylogenetic densities for MSM with HCV (3, interquartile range 1-7) and without HCV (3, interquartile range 1-8) were similar. HCV phylogeny showed 12 MSM-specific HCV clusters (clustersize: 2-39 HCV sequences); 12.7% of HCV infections were part of the same HIV and HCV cluster. We observed few HIV clusters with elevated HCV prevalence, no increase in the HIV phylogenetic density of HIV/HCV-coinfected MSM compared to HIV-infected MSM without HCV, and limited overlap between HIV and HCV phylogenies among HIV/HCV-coinfected MSM. Our data do not support the existence of MSM-specific sexual networks that fuel both the HIV and HCV epidemic.
Wu, Shaowei; Gennings, Chris; Wright, Rosalind J; Wilson, Ander; Burris, Heather H; Just, Allan C; Braun, Joseph M; Svensson, Katherine; Zhong, Jia; Brennan, Kasey J M; Dereix, Alexandra; Cantoral, Alejandra; Schnaas, Lourdes; Téllez-Rojo, Martha Maria; Wright, Robert O; Baccarelli, Andrea A
2018-01-01
Maternal stress during pregnancy may influence childhood growth and adiposity, possibly through immune/inflammatory programming. We investigated whether exposure to prenatal stress and methylation in inflammation-related genes were associated with childhood adiposity in 424 mother-child pairs in Mexico City, Mexico. A stress index was created based on four prenatally administered stress-related scales (Exposure to Violence, Crisis in Family Systems, State-Trait Anxiety Inventory, and Edinburgh Postnatal Depression Scale). We measured weight, height, body fat mass (BFM), percentage body fat (PBF), and waist circumference in early childhood (age range, 4-6 years). Body mass index (BMI) z scores were calculated according to World Health Organization standards. DNA methylation in gene promoters of tumor necrosis factor α, interleukin 8, and interleukin 6 (IL6) in umbilical cord blood were determined by pyrosequencing. An interquartile range increase in stress index (27.3) was associated with decreases of 0.14 unit in BMI z score (95% confidence interval [CI] = -0.28 to -0.005), 5.6% in BFM (95% CI = -9.7 to -1.4), 3.5% in PBF (95% CI = -6.3 to -0.5), and 1.2% in waist circumference (95% CI = -2.4 to -0.04) in multivariable-adjusted models. An interquartile range increase in IL6 methylation (3.9%) was associated with increases of 0.23 unit in BMI z score (95% CI = 0.06-0.40), 8.1% (95% CI = 2.3-14.3) in BFM, 5.5% (95% CI = 1.7-9.5) in PBF, and 1.7% (95% CI = 0.2-3.3) in waist circumference. Prenatal stress was associated with decreased childhood adiposity, whereas cord blood IL6 methylation was associated with increased childhood adiposity in Mexican children.
Kaida, Angela; Matthews, Lynn T; Ashaba, Scholastic; Tsai, Alexander C; Kanters, Steve; Robak, Magdalena; Psaros, Christina; Kabakyenga, Jerome; Boum, Yap; Haberer, Jessica E; Martin, Jeffrey N; Hunt, Peter W; Bangsberg, David R
2014-12-01
Among HIV-infected women, perinatal depression compromises clinical, maternal, and child health outcomes. Antiretroviral therapy (ART) is associated with lower depression symptom severity but the uniformity of effect through pregnancy and postpartum periods is unknown. We analyzed prospective data from 447 HIV-infected women (18-49 years) initiating ART in rural Uganda (2005-2012). Participants completed blood work and comprehensive questionnaires quarterly. Pregnancy status was assessed by self-report. Analysis time periods were defined as currently pregnant, postpartum (0-12 months post-pregnancy outcome), or non-pregnancy-related. Depression symptom severity was measured using a modified Hopkins Symptom Checklist 15, with scores ranging from 1 to 4. Probable depression was defined as >1.75. Linear regression with generalized estimating equations was used to compare mean depression scores over the 3 periods. At enrollment, median age was 32 years (interquartile range: 27-37), median CD4 count was 160 cells per cubic millimeter (interquartile range: 95-245), and mean depression score was 1.75 (s = 0.58) (39% with probable depression). Over 4.1 median years of follow-up, 104 women experienced 151 pregnancies. Mean depression scores did not differ across the time periods (P = 0.75). Multivariable models yielded similar findings. Increasing time on ART, viral suppression, better physical health, and "never married" were independently associated with lower mean depression scores. Findings were consistent when assessing probable depression. Although the lack of association between depression and perinatal periods is reassuring, high depression prevalence at treatment initiation and continued incidence across pregnancy and non-pregnancy-related periods of follow-up highlight the critical need for mental health services for HIV-infected women to optimize both maternal and perinatal health.
Vaswani, Devin; Wallace, Adam N; Eiswirth, Preston S; Madaelil, Thomas P; Chang, Randy O; Tomasian, Anderanik; Jennings, Jack W
2018-03-14
To evaluate the effectiveness of percutaneous image-guided thermal ablation in achieving local tumor control and pain palliation of sarcoma metastases within the musculoskeletal system. Retrospective review of 64 sarcoma metastases within the musculoskeletal system in 26 women and 15 men (total = 41) treated with ablation between December 2011 and August 2016 was performed. Mean age of the cohort was 42.9 years ± 16.0 years. Two subgroups were treated: oligometastatic disease (n = 13) and widely metastatic disease (n = 51). A variety of sarcoma histologies were treated with average tumor volume of 42.5 cm 3 (range 0.1-484.7 cm 3 ). Pain scores were recorded before and 4 weeks after therapy for 59% (38/64) of treated lesions. Follow-up imaging was evaluated for local control and to monitor sites of untreated disease as an internal control. Fifty-eight percent (37/64) were lost to imaging follow-up at varying time points over a year. Complication rate was 5% (3/64; one minor and two major events). One-year local tumor control rates were 70% (19/27) in all patients, 67% (12/18) in the setting of progression of untreated metastases, and 100% (10/10) in the setting of oligometastatic disease. Median pain scores decreased from 8 (interquartile range 5.0-9.0) to 3 (interquartile range 0.1-4.0) 1 month after the procedure (P < 0.001). Image-guided percutaneous ablation is an effective option for local tumor control and pain palliation of metastatic sarcomas within the musculoskeletal system. Treatment in the setting of oligometastatic disease offers potential for remission. Level 4, Retrospective Review.
HIP AND GLENOHUMERAL PASSIVE RANGE OF MOTION IN COLLEGIATE SOFTBALL PLAYERS
Plummer, Hillary; Brambeck, Allison
2016-01-01
Background and Purpose Range of motion deficits at the hip and glenohumeral joint (GHJ) may contribute to the incidence of injury in softball players. With injury in softball players on the rise, softball related studies in the literature are important. The purpose of this study was to examine hip and GHJ passive range of motion (PROM) patterns in collegiate softball players. Hypothesis It was hypothesized that the position players would exhibit significantly different PROM patterns than pitchers. Additionally, position players would exhibit significantly different side-to-side differences in PROM for both the hip and GHJ compared to pitchers. Study Design Prospective cohort study. Methods Forty-nine collegiate softball players (19.63 ± 1.15 years; 170.88 ± 8.08 cm; 72.96 ± 19.41 kg) participated. Passive hip and GHJ internal (IR) and external rotation (ER) measures were assessed. Glenohumeral PROM was measured with the participants supine with the arm abducted to 90 °. The measurements were recorded when the scapula began to move or a firm capsular end-feel was achieved. The hip was positioned in 90 ° of flexion and passively rotated until a capsular end-feel was achieved. Total PROM was calculated by taking the sum of IR and ER for both the hip and GHJ. Results No significant side-to-side PROM differences were observed in pitchers, at the GHJ or hip joint. Position players throwing side hip IR was significantly greater than the non-throwing side hip (p = 0.002). The non-throwing side hip had significantly greater ER compared to the throwing side hip (p = 0.002). When examining side-to-side differences at the GHJ, IR was significantly greater in the non-throwing shoulder (p = 0.047). No significant differences in total range of motion of the hip and GHJ were observed. Conclusion In the current study, position players displayed side-to-side differences in hip and GHJ IR PROM while no statistically significant differences were observed in the softball pitchers. The findings of the current study add to the body of literature related to PROM in throwing athletes, additionally these are the first hip IR and ER PROM data presented in softball players. Level of Evidence Level 3 PMID:27757286
NASA Technical Reports Server (NTRS)
Wasson, J. T.; Schaudy, R.; Bild, R. W.; Chou, C.-L.
1974-01-01
The metal from 17 mesosiderites has been analyzed for Ni, Ga, Ge, and Ir by the techniques of atomic-absorption spectrometry and neutron activation. Most mesosiderite metal samples fall in a narrow compositional range: Ni, 7.0-9.0%; Ga, 13-16 ppm; Ge, 47-58 ppm; and Ir, 2.4-4.4 ppm. Most of those falling outside these ranges belong to Powell's (1971) least-metamorphosed type. Mesosiderite metal falls in the same general composition range as IIIAB irons, IIIE irons, pallasites and H-group chondrite metal. There are distinct differences in detail, however, and firm evidence for a close genetic relationship between any of these groups and the mesosiderites is lacking.
NASA Astrophysics Data System (ADS)
Tu-ya; Yang, Ping; Sun, Su-qin; Zhou, Qun; Bao, Xiao-hua; Noda, Isao
2010-06-01
Fourier-transform infrared spectroscopy (FTIR) and two-dimensional correlation infrared spectroscopy (2D-IR)) are employed to analyze various processed products and ether extracts of Radix Aconiti kusnezoffii. There is a resemblance among the spectra of different processed products. The major difference lies in the absorption peak at 1641 cm -1 in the IR spectra, which reflects the transformation of raw aconite to the processed products. There are distinctive differences in the absorption peaks in the range of 1800-1500 cm -1 in the second derivative spectra, which has better resolution, of different processed products. 2D-IR spectra, which elevate the resolution further, can present even more differences among the products in the range of 1800-800 cm -1. Analysis of ether extracts of various processed products proves that there are alcohols, esters, carboxylic acids or ketones in all of them. However, their contents in different samples have obvious differences. With the advantages of high resolution, high-speed and convenience, IR can quickly and precisely distinguish various processed products of Radix A. kusnezoffii, and can be applied to predict the tendency of transformation of the complicated chemical mixture systems under heat perturbation.
Measurements of Plasma Power Losses in the C-2 Field-Reversed Configuration Experiment
NASA Astrophysics Data System (ADS)
Korepanov, Sergey; Smirnov, Artem; Garate, Eusebio; Donin, Alexandr; Kondakov, Alexey; Singatulin, Shavkat
2013-10-01
A high-confinement operating regime with plasma lifetimes significantly exceeding past empirical scaling laws was recently obtained by combining plasma gun edge biasing and tangential Neutral Beam Injection in the C-2 field-reversed configuration (FRC) experiment. To analyze the power balance in C-2, two new diagnostic instruments - the pyroelectric (PE) and infrared (IR) bolometers - were developed. The PE bolometer, designed to operate in the incident power density range from 0.1-100 W/cm2, is used to measure the radial power loss, which is dominated by charge-exchange neutrals and radiation. The IR bolometer, which measures power irradiated onto a thin metal foil inserted in the plasma, is designed for the power density range from 0.5-5 kW/cm2. The IR bolometer is used to measure the axial power loss from the plasma near the end divertors. The maximum measurable pulse duration of ~ 10 ms is limited by the heat capacitance of the IR detector. Both detectors have time resolution of about 10-100 μs and were calibrated in absolute units using a high power neutral beam. We present the results of first direct measurements of axial and radial plasma power losses in C-2.
Liu, Feng; Dumont, Charles; Zhu, Yongjin; DeGrado, William F; Gai, Feng; Gruebele, Martin
2009-02-14
We present fluorescence-detected measurements of the temperature-jump relaxation kinetics of the designed three-helix bundle protein alpha(3)D taken under solvent conditions identical to previous infrared-detected kinetics. The fluorescence-detected rate is similar to the IR-detected rate only at the lowest temperature where we could measure it (326 K). The fluorescence-detected rate decreases by a factor of 3 over the 326-344 K temperature range, whereas the IR-detected rate remains nearly constant over the same range. To investigate this probe dependence, we tested an extensive set of physically reasonable one-dimensional (1D) free energy surfaces by Langevin dynamics simulation. The simulations included coordinate- and temperature-dependent roughness, diffusion coefficients, and IR/fluorescence spectroscopic signatures. None of these can reproduce the IR and fluorescence data simultaneously, forcing us to the conclusion that a 1D free energy surface cannot accurately describe the folding of alpha(3)D. This supports the hypothesis that alpha(3)D has a multidimensional free energy surface conducive to downhill folding at 326 K, and that it is already an incipient downhill folder with probe-dependent kinetics near its melting point.
Gatus, Mark R D; Bhadbhade, Mohan; Messerle, Barbara A
2017-10-24
Two highly versatile xanthene scaffolds containing pairs of heteroditopic ligands were found to be capable of accommodating a range of transition metal ions, including Au(i), Ir(i), Ir(iii), Rh(i), and Ru(ii) to generate an array of heterobimetallic complexes. The metal complexes were fully characterised and proved to be stable in the solid and solution state, with no observed metal-metal scrambling. Heterobimetallic complexes containing the Rh(i)/Ir(i) combinations were tested as catalysts for the two-step dihydroalkoxylation reaction of alkynediols and sequential hydroamination/hydrosilylation reaction of alkynamines.
A new high efficiency InP acousto-optic device for IR wavelengths
NASA Astrophysics Data System (ADS)
Soos, Jolanta I.; Rosemeier, Ronald G.; Rosenbaum, Joel
1990-09-01
InP acoustooptic Bragg cells which are IR-transparent in the 1-10 micron bandpass have a center frequency in the 200-600 MHz range, and a diffraction efficiency of 40-60 percent, on the basis of 1-W RF driving power. These devices are anticipated to be ideal in such applications as fiber-optic modulators, IR scanners, deflectors, and HF mode-lockers. In the course of fabrication, the photoelastic constant p44 has been defined; using other crystallographic configurations, such photoelastic constants as p11 and p12 are expected to emerge.
Intrinsic Raman spectroscopy for quantitative biological spectroscopy Part II
Bechtel, Kate L.; Shih, Wei-Chuan; Feld, Michael S.
2009-01-01
We demonstrate the effectiveness of intrinsic Raman spectroscopy (IRS) at reducing errors caused by absorption and scattering. Physical tissue models, solutions of varying absorption and scattering coefficients with known concentrations of Raman scatterers, are studied. We show significant improvement in prediction error by implementing IRS to predict concentrations of Raman scatterers using both ordinary least squares regression (OLS) and partial least squares regression (PLS). In particular, we show that IRS provides a robust calibration model that does not increase in error when applied to samples with optical properties outside the range of calibration. PMID:18711512
Chow, Shiao Y; Stevens, Marc Y; Åkerbladh, Linda; Bergman, Sara; Odell, Luke R
2016-06-27
A novel, mild and facile preparation of alkyl amides from unactivated alkyl iodides employing a fac-Ir(ppy)3 -catalyzed radical aminocarbonylation protocol has been developed. Using a two-chambered system, alkyl iodides, fac-Ir(ppy)3 , amines, reductants, and CO gas (released ex situ from Mo(CO)6 ), were combined and subjected to an initial radical reductive dehalogenation generating alkyl radicals, and a subsequent aminocarbonylation with amines affording a wide range of alkyl amides in moderate to excellent yields. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Case-Control Study on the Impact of Ventilator-Associated Tracheobronchitis in the PICU.
Wheeler, Derek S; Whitt, John D; Lake, Michael; Butcher, John; Schulte, Marion; Stalets, Erika
2015-07-01
Hospital-acquired infections increase morbidity, mortality, and charges in the PICU. We implemented a quality improvement bundle directed at ventilator-associated pneumonia in our PICU in 2005. We observed an increase in ventilator-associated tracheobronchitis coincident with the near-elimination of ventilator-associated pneumonia. The impact of ventilator-associated tracheobronchitis on critically ill children has not been previously described. Accordingly, we hypothesized that ventilator-associated tracheobronchitisis associated with increased length of stay, mortality, and hospital charge. Retrospective case-control study. Critically ill children admitted to a quaternary PICU at a free-standing academic children's hospital in the United States. None. We conducted a retrospective case control study, with institutional review board approval, of 77 consecutive cases of ventilator-associated tracheobronchitis admitted to our PICU from 2004-2010. We matched each case with a control based on the following criteria (in rank order): age range (< 30 d, 30 d to 24 mo, 24 mo to 12 yr, > 12 yr), admission Pediatric Risk of Mortality III score ± 10, number of ventilator days of control group (> 75% of days until development of ventilator-associated tracheobronchitis), primary diagnosis, underlying organ system dysfunction, surgical procedure, and gender. The primary outcome measured was PICU length of stay. Secondary outcomes included ventilator days, hospital length of stay, mortality, and PICU and hospital charges. Data was analyzed using chi square analysis and p less than 0.05 was considered significant. We successfully matched 45 of 77 ventilator-associated tracheobronchitis patients with controls. There were no significant differences in age, gender, diagnosis, or Pediatric Risk of Mortality III score between groups. Ventilator-associated tracheobronchitis patients had a longer PICU length of stay (median, 21.5 d, interquartile range, 24 d) compared to controls (median, 18 d; interquartile range, 17 d), although not statistically significant (p = 0.13). Ventilator days were also longer in the ventilator-associated tracheobronchitis patients (median, 17 d; IQR, 22 d) versus control (median, 10.5 d; interquartile range, 13 d) (p = 0.01). There was no significant difference in total hospital length of stay (54 d vs 36 d; p = 0.69). PICU mortality was higher in the ventilator-associated tracheobronchitis group (15% vs 5%; p = 0.14), although not statistically significant. There was an increase in both median PICU charges ($197,393 vs $172,344; p < 0.05) and hospital charges ($421,576 vs $350,649; p < 0.05) for ventilator-associated tracheobronchitis patients compared with controls. Ventilator-associated tracheobronchitis is a clinically significant hospital-acquired infection in the PICU and is associated with longer duration of mechanical ventilation and healthcare costs, possibly through causing a longer PICU length of stay. Quality improvement efforts should be directed at reducing the incidence of ventilator-associated tracheobronchitis in the PICU.
High dynamic range infrared radiometry and imaging
NASA Technical Reports Server (NTRS)
Coon, Darryl D.; Karunasiri, R. P. G.; Bandara, K. M. S. V.
1988-01-01
The use is described of cryogenically cooled, extrinsic silicon infrared detectors in an unconventional mode of operation which offers an unusually large dynamic range. The system performs intensity-to-frequency conversion at the focal plane via simple circuits with very low power consumption. The incident IR intensity controls the repetition rate of short duration output pulses over a pulse rate dynamic range of about 10(6). Theory indicates the possibility of monotonic and approx. linear response over the full dynamic range. A comparison between the theoretical and the experimental results shows that the model provides a reasonably good description of experimental data. Some measurements of survivability with a very intense IR source were made on these devices and found to be very encouraging. Evidence continues to indicate that some variations in interpulse time intervals are deterministic rather than probabilistic.
Riyapan, Sattha; Lubin, Jeffrey
2016-03-01
We attempted to determine the effect of prearrival instructions that included the specific location of automated external defibrillators (AEDs) in a public venue on the time to defibrillation in a simulated cardiac arrest scenario using untrained bystanders. The study was a randomized controlled trial at an urban shopping mall. Participants were asked to retrieve an AED and come back to defibrillate a mannequin. Only the experimental group received the location of the AED. We measured the percentage of shocks that were delivered in less than 3 minutes from the start of the scenario and also recorded several other time intervals. Thirty-nine participants completed the study, with 20 participants in the experimental group. The median time to defibrillation in the experimental group was 2.6 minutes (interquartile range, 2.4-2.8) which was significantly less than the control group's median time of 5.9 minutes (interquartile range, 4.38-7.65). Ninety percent (95% confidence interval, 68.3%-98.8%) of the participants in the experimental group defibrillated within 3 minutes, which was significantly different from the control group (10.5%; 95% confidence interval, 1.3%-33.1%). In this study, a prearrival protocol providing participants with the location of the nearest AED in a public building resulted in a significant decrease in the time required to deliver a simulated shock. Further investigations in various types of public settings are needed to confirm the results. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Hui; Tian, Yaohua; Song, Jing; Cao, Yaying; Xiang, Xiao; Huang, Chao; Li, Man; Hu, Yonghua
2018-03-01
There is growing interest in the association between ambient air pollution and congestive heart failure (CHF), but research data from developing countries are very limited. The primary aim of this study was to examine the association between short-term exposure to air pollution and hospital admission for CHF in China. A time-stratified case-crossover study was conducted between 2014 and 2015 in 26 large Chinese cities among 105,501 CHF hospitalizations. Conditional logistic regression models were applied to estimate the percentage changes in CHF admissions in relation to per interquartile range increases in air pollutant concentrations. Air pollution was positively associated with CHF hospitalizations. An interquartile range increase in fine particulate, particulate matter less than 10 µm in aerodynamic diameter, sulfur dioxide, nitrogen dioxide, carbon monoxide, and ozone concentrations on the current day corresponded to 1.2% (95% confidence interval [CI] 0.5%, 1.8%), 1.3% (95% CI 0.5%, 2.0%), 1.0% (95% CI 0.2%, 1.7%), 1.6% (95% CI 0.6%, 2.5%), 1.2% (95% CI 0.5%, 1.9%), and 0.4% (95% CI -0.9%, 1.7%) increases in CHF admissions, respectively. In conclusion, our findings contribute to the limited scientific literature concerning the effects of air pollution on CHF risk for high-exposure settings typical in developing countries, which may have significant public health implications for prevention of CHF in China. Copyright © 2017 Elsevier Inc. All rights reserved.
Nazeri, Pantea; Mirmiran, Parvin; Mehrabi, Yadollah; Hedayati, Mehdi; Delshad, Hossein; Azizi, Fereidoun
2010-12-01
Production of iodized salt in Iran for household consumption began in 1990. Previous studies have reported sustainable elimination of iodine deficiency disorders in Iran. The aim of this study was to evaluate the iodine nutritional status in Tehran in 2009. In this cross-sectional study, 383 Tehranian households were enrolled through randomized cluster sampling and a total of 639 adult subjects (242 men and 397 women), aged 19 and over, participated. A 24-hour urine sample was collected for measurement of urinary iodine, sodium, and creatinine concentrations using the digestion method, flame photometry, and autoanalyzer assay, respectively. Salt intake was estimated and iodine content of household salt was measured by titration. Median (interquartile range) iodine content of household salt and urinary iodine concentration (UIC) in Tehran were 21.2 (3.2-31.7) parts per million and 70.0 (34.0-131.2) μg/L, respectively. There was no statistically significant difference in 24-hour UICs between men and women. Median (interquartile range) daily salt intake was 7.6 (5.5-9.8) g, which was not different in the two genders. According to the WHO/ICCIDD/UNICEF classification, 11.2%, 25.9%, 26.7%, 25.1%, 8.0%, and 3.2% of participants had UIC <20, 20-49, 50-99, 100-199, 200-299, and >300 μg/L, respectively. Mild iodine deficiency has recurred in Tehranians. The results emphasize the need for continuous monitoring in all regions, even in a country with iodine sufficiency.
Recipient Age and Mortality Risk after Liver Transplantation: A Population-Based Cohort Study.
Chen, Hsiu-Pin; Tsai, Yung-Fong; Lin, Jr-Rung; Liu, Fu-Chao; Yu, Huang-Ping
2016-01-01
The aim of the present large population-based cohort study is to explore the risk factors of age-related mortality in liver transplant recipients in Taiwan. Basic information and data on medical comorbidities for 2938 patients who received liver transplants between July 1, 1998, and December 31, 2012, were extracted from the National Health Insurance Research Database on the basis of ICD-9-codes. Mortality risks were analyzed after adjusting for preoperative comorbidities and compared among age cohorts. All patients were followed up until the study endpoint or death. This study finally included 2588 adults and 350 children [2068 (70.4%) male and 870 (29.6%) female patients]. The median age at transplantation was 52 (interquartile range, 43-58) years. Recipients were categorized into the following age cohorts: <20 (n = 350, 11.9%), 20-39 (n = 254, 8.6%), 40-59 (n = 1860, 63.3%), and ≥60 (n = 474, 16.1%) years. In the total population, 428 deaths occurred after liver transplantation, and the median follow-up period was 2.85 years (interquartile range, 1.2-5.5 years). Dialysis patients showed the highest risk of mortality irrespective of age. Further, the risk of death increased with an increase in the age at transplantation. Older liver transplant recipients (≥60 years), especially dialysis patients, have a higher mortality rate, possibly because they have more medical comorbidities. Our findings should make clinicians aware of the need for better risk stratification among elderly liver transplantation candidates.
Effect of collaborative care on cost variation in an intensive care unit.
Garland, Allan
2013-05-01
Improving the cost-effectiveness of health care requires an understanding of the genesis of health care costs and in particular the sources of cost variation. Little is known about how multiple physicians, caring collaboratively for patients, contribute to costs. To explore the effect of collaborative care by physicians on variation in discretionary costs in an intensive care unit (ICU) by determining the contributions of the attending intensivists and ICU fellows. Prospective, observational study using a multivariable model of median discretionary costs for the first day in the ICU, adjusting for confounding variables. Analysis included 3514 patients who spent more than 2 hours in the ICU on the initial day. Impact of the physicians was assessed via variables representing the specific intensivist and ICU fellow responsible on the first ICU day and allowing for interaction terms. On the initial day, patients spent a median of 10.6 hours (interquartile range, 6.3-16.5) in the ICU, with median discretionary costs of $1343 (interquartile range, $788-2208). There was large variation in adjusted costs attributable to both the intensivists ($359; 95% CI, $244-$474) and the fellows ($756; 95% CI, $550-$965). The interaction terms were not significant (P = .12-.79). In an ICU care model with intensivists and subspecialty fellows, both types of physicians contributed significantly to the observed variation in discretionary costs. However, even in the presence of a hierarchical arrangement of clinical responsibilities, the influences on costs of the 2 types of physicians were independent.
Katheria, Anup; Rich, Wade; Finer, Neil
2012-11-01
To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions.
Quantification of Maternal Serum Cell-Free Fetal DNA in Early-Onset Preeclampsia
Yu, Hong; Shen, Yanting; Ge, Qinyu; He, Youji; Qiao, Dongyan; Ren, Mulan; Zhang, Jianqiong
2013-01-01
The aim of this study was to determine whether the increased serum cell-free fetal DNA (cffDNA) level of gravidas developed into early-onset preeclampsia (EOPE) subsequently in the early second trimesters is related to prenatal screening markers. Serum was collected from 1011 gravidas. The level of cffDNA and prenatal screening markers were analyzed in 20 cases with EOPE and 20 controls. All fetuses were male. The maternal serum cffDNA level was assessed by amplification of the Y chromosome specific gene. Correlations between the variables were examined. (Logged) cffDNA in EOPE (median, 3.08; interquartile range, 2.93–3.68) was higher than controls (median, 1.79; interquartile range, 1.46–2.53). The increased level of (logged) cffDNA was correlated significantly with the increased human chorionic gonadotropin (HCG) level (r = 0.628, p < 0.001). Significant reciprocal correlations between cffDNA and babies’ birth weight as well as gestation weeks at delivery were noted (r = −0.516, p = 0.001; r = −0.623, p < 0.001, respectively). The sensitivity and specificity of cffDNA to discriminate between the EOPE cases and the controls were 90% and 85%, respectively. CffDNA is a potential marker for EOPE, which had a significant reciprocal correlation with babies’ birth weight and gestation weeks at delivery. Moreover, it may help in indicating the underlying hypoxic condition in the placenta. PMID:23567271
Unger, L W; Muckenhuber, M; Riss, S; Argeny, S; Stift, J; Mesteri, I; Stift, A
2018-04-28
As adjuvant chemotherapy in colorectal cancer relies on the identification of lymph node metastases, the pathologist's dedication may have a considerable influence on postoperative survival. The aim of this retrospective study was to assess the impact of the pathologist's dedication on lymph node detection rate and postoperative survival in patients operated on by a single experienced colorectal surgeon within a 5-year period. We assessed 229 patients undergoing total mesorectal excision or complete mesocolic excision by the senior author between 1 January 2009 and 31 December 2013. Pathologists were grouped as 'general pathologist' or 'dedicated pathologist' depending on their dedication/specialization. Dedicated pathologists found statistically significantly more lymph nodes in colorectal specimens than general pathologists [23 (interquartile range 24) vs 14 (interquartile range 11), respectively; P < 0.001]. The detection rate of ≥ 12 lymph nodes per specimen was significantly higher in the dedicated pathologist group [65/74 (87.8%) vs 105/155 (67.7%); P = 0.016]. However, postoperative survival did not differ in the respective subgroups. In the multivariable analysis by Cox proportional hazard model, International Union against Cancer Stage IV was the only factor associated with decreased disease-specific survival (hazard ratio 28.257; 95% CI 3.850-207.386; P = 0.001). In our centre, the pathologist's dedication has an impact on lymph node detection rate but does not influence postoperative disease-specific survival. Colorectal Disease © 2018 The Association of Coloproctology of Great Britain and Ireland.
Tang, Tien; Abbott, Sally; le Roux, Carel W; Wilson, Violet; Singhal, Rishi; Bellary, Srikanth; Tahrani, Abd A
2018-03-01
We examined the relationship between weight changes after preoperative glucagon-like peptide-1 receptor agonist (GLP-1RA) treatment and weight changes from the start of medical weight management (MWM) until 12 months after bariatric surgery in patients with type 2 diabetes in a retrospective cohort study. A total of 45 patients (64.4% women, median [interquartile range] age 49 [45-60] years) were included. The median (interquartile range) weight loss from start of MWM until 12 months post-surgery was 17.9% (13.0%-29.3%). GLP-1RA treatment during MWM resulted in 5.0% (1.9%-7.7%) weight loss. Weight loss during GLP-1RA treatment predicted weight loss from the start of MWM until 12 months post-surgery, but not postoperative weight loss after adjustment. The proportion of weight loss from start of MWM to 12 months post-surgery attributed to GLP-1RA treatment was negatively associated with that attributed to surgery, after adjustment. In conclusion, weight change after GLP-1RA treatment predicted the weight loss achieved by a combination of MWM and bariatric surgery, but not weight loss induced by surgery only. Failure to lose weight after GLP-1RA treatment should not be considered a barrier to undergoing bariatric surgery. © 2017 John Wiley & Sons Ltd.
Threlkeld, Zachary D; Kozak, Benjamin; McCoy, David; Cole, Sara; Martin, Christine; Singh, Vineeta
2017-07-01
Shorter time-to-thrombolysis in acute ischemic stroke (AIS) is associated with improved functional outcome and reduced morbidity. We evaluate the effect of several interventions to reduce time-to-thrombolysis at an urban, public safety net hospital. All patients treated with tissue plasminogen activator for AIS at our institution between 2008 and 2015 were included in a retrospective analysis of door-to-needle (DTN) time and associated factors. Between 2011 and 2014, we implemented 11 distinct interventions to reduce DTN time. Here, we assess the relative impact of each intervention on DTN time. The median DTN time pre- and postintervention decreased from 87 (interquartile range: 68-109) minutes to 49 (interquartile range: 39-63) minutes. The reduction was comprised primarily of a decrease in median time from computed tomography scan order to interpretation. The goal DTN time of 60 minutes or less was achieved in 9% (95% confidence interval: 5%-22%) of cases preintervention, compared with 70% (58%-81%) postintervention. Interventions with the greatest impact on DTN time included the implementation of a stroke group paging system, dedicated emergency department stroke pharmacists, and the development of a stroke code supply box. Multidisciplinary, collaborative interventions are associated with a significant and substantial reduction in time-to-thrombolysis. Such targeted interventions are efficient and achievable in resource-limited settings, where they are most needed. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
A Prospective Study of Serum Trace Elements in Healthy Korean Pregnant Women
Choi, Rihwa; Sun, Jiyu; Yoo, Heejin; Kim, Seonwoo; Cho, Yoon Young; Kim, Hye Jeong; Kim, Sun Wook; Chung, Jae Hoon; Oh, Soo-young; Lee, Soo-Youn
2016-01-01
This prospective study sought to investigate serum levels of trace elements (cobalt, copper, zinc, and selenium) and to assess their effects on pregnancy and neonatal outcomes. Serum levels of trace elements in 245 Korean pregnant women (median gestational age at delivery was 39 + 4 weeks and interquartile range was 38 + 4–40 + 1 weeks) were compared with those of 527 general adults and those of previous studies in other ethnic groups. Pregnancy and neonatal outcomes including gestational diabetes, preeclampsia, neonatal birth weight, and congenital abnormalities were assessed. The median serum trace element concentrations of all pregnant women were: cobalt: 0.39 μg/L (interquartile range, IQR 0.29–0.53), copper: 165.0 μg/dL (IQR 144.0–187.0), zinc: 57.0 μg/dL (IQR 50.0–64.0), and selenium: 94.0 μg/L (IQR 87.0–101.0). Serum cobalt and copper concentrations were higher in pregnant women than in the general population, whereas zinc and selenium levels were lower (p < 0.01). Concentrations of all four trace elements varied significantly during the three trimesters (p < 0.05), and seasonal variation was found in copper, zinc, and selenium, but was not observed for cobalt. The prevalence of preeclampsia was significantly lower with high copper (p = 0.03). Trace element levels varied by pregnancy trimester and season, and alteration in copper status during pregnancy might influence pregnancy outcomes such as preeclampsia. PMID:27886083
A Prospective Study of Serum Trace Elements in Healthy Korean Pregnant Women.
Choi, Rihwa; Sun, Jiyu; Yoo, Heejin; Kim, Seonwoo; Cho, Yoon Young; Kim, Hye Jeong; Kim, Sun Wook; Chung, Jae Hoon; Oh, Soo-Young; Lee, Soo-Youn
2016-11-23
This prospective study sought to investigate serum levels of trace elements (cobalt, copper, zinc, and selenium) and to assess their effects on pregnancy and neonatal outcomes. Serum levels of trace elements in 245 Korean pregnant women (median gestational age at delivery was 39 + 4 weeks and interquartile range was 38 + 4-40 + 1 weeks) were compared with those of 527 general adults and those of previous studies in other ethnic groups. Pregnancy and neonatal outcomes including gestational diabetes, preeclampsia, neonatal birth weight, and congenital abnormalities were assessed. The median serum trace element concentrations of all pregnant women were: cobalt: 0.39 μg/L (interquartile range, IQR 0.29-0.53), copper: 165.0 μg/dL (IQR 144.0-187.0), zinc: 57.0 μg/dL (IQR 50.0-64.0), and selenium: 94.0 μg/L (IQR 87.0-101.0). Serum cobalt and copper concentrations were higher in pregnant women than in the general population, whereas zinc and selenium levels were lower ( p < 0.01). Concentrations of all four trace elements varied significantly during the three trimesters ( p < 0.05), and seasonal variation was found in copper, zinc, and selenium, but was not observed for cobalt. The prevalence of preeclampsia was significantly lower with high copper ( p = 0.03). Trace element levels varied by pregnancy trimester and season, and alteration in copper status during pregnancy might influence pregnancy outcomes such as preeclampsia.
Barriers and facilitators of sports in Dutch Paralympic athletes: An explorative study.
Jaarsma, E A; Geertzen, J H B; de Jong, R; Dijkstra, P U; Dekker, R
2014-10-01
The purpose of this study was to gain insight in barriers and facilitators of sports in paralympic athletes. An online questionnaire was distributed through the Netherlands Olympic Committee and National Sports Confederation to determine personal and environmental barriers and facilitators of sports participation. The International Classification of Functioning, Disability and Health model and theory of planned behavior were used to respectively categorize the results in environmental and personal factors, and attitude, subjective norm and perceived behavioral control. Seventy-six Dutch Paralympic athletes completed the questionnaire (51% response rate). Barriers and facilitators experienced by ambulant and wheelchair athletes were compared. Most frequently mentioned personal barrier was dependency of others (22%), while most frequently mentioned environmental barrier was lack of sports facilities (30%). Wheelchair athletes mentioned more barriers (median = 3, interquartile range: 0.5-6), than ambulant athletes (median = 1.0,interquartile range:0.0-3.0, P = 0.023). One-third of the athletes did not experience any barriers. Most frequently mentioned personal facilitators to initiate sports participation were fun (78%), health (61%), and competition (53%). Most frequently mentioned environmental facilitator was social support (40%). This study indicated that barriers of sport were mostly environmental, while facilitators were usually personal factors. Attitude and subjective norm were considered the most important components for intention to participation in sports. The facilitators outweighed the barriers and kept the athletes being active in sports. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Interdisciplinary simulation-based training to improve delivery room communication.
Dadiz, Rita; Weinschreider, Joanne; Schriefer, Jan; Arnold, Christine; Greves, Cole D; Crosby, Erin C; Wang, Hongyue; Pressman, Eva K; Guillet, Ronnie
2013-10-01
Poor communication among obstetric and pediatric professionals is associated with adverse perinatal events leading to severe disability and neonatal mortality. This study evaluated the effectiveness of an interdisciplinary simulation-based training (SBT) program to improve delivery room communication between obstetric and pediatric teams. Obstetric and pediatric teams participated in an SBT annually during 3 academic years, 2008-2011 (Y1-Y3), in a prospective, observational study. Eligible participants (n = 228) included attendings, fellows, house staff, midlevel providers, and nurses involved in delivery room care. Simulations were videotaped and evaluated using a validated 20-item checklist of best communication practices. Checklist scores were compared across years with the Kruskal-Wallis test. Providers were also surveyed annually regarding communication during actual deliveries using a standardized questionnaire. Ratings were analyzed using two-way analysis of covariance. At least 60% of eligible providers participated in 1 or more SBT sessions and completed surveys annually. Checklist scores on communication during SBT improved from Y1 (median, 6; interquartile range, 4) to Y3 (median, 11; interquartile range, 6) (P < 0.001). Survey results showed the perception of improvement over time in interteam communication during actual deliveries by obstetric (P < 0.005) and pediatric (P < 0.0001) providers. The obstetric team also perceived improved provider communication with the family (P < 0.05). Communication during SBT as well as the perception of communication during actual deliveries improved across the study period. The potential of a checklist to standardize delivery room communication and improve patient outcomes merits further investigation.
Buckingham, Bruce A; Beck, Roy W; Ruedy, Katrina J; Cheng, Peiyao; Kollman, Craig; Weinzimer, Stuart A; DiMeglio, Linda A; Bremer, Andrew A; Slover, Robert; Cantwell, Martin
2013-05-01
This article describes our experience with inpatient hybrid closed-loop control (HCLC) initiated shortly after the diagnosis of type 1 diabetes in a randomized trial designed to assess the effectiveness of inpatient HCLC followed by outpatient sensor-augmented pump (SAP) therapy on the preservation of β-cell function. Forty-eight individuals with newly diagnosed type 1 diabetes and positive pancreatic autoantibodies (7.8-37.7 years old) received inpatient HCLC therapy for up to 93 h, initiated within 7 days of diagnosis. On initiation of HCLC, mean glucose concentration was 240±100 mg/dL. During the first day of HCLC, median of the participant's mean glucose concentrations fell rapidly to 146 mg/dL, a level of control that was sustained on Days 2 and 3 (138 mg/dL and 139 mg/dL, respectively). By Day 3, the median percentage of glucose values >250 and <60 mg/dL was <1%. During the first 2 weeks of SAP treatment at home, the median participant mean glucose level was 126 mg/dL (interquartile range, 117, 137 mg/dL), and the median percentage of values between 71 and 180 mg/dL was 85% (interquartile range, 80%, 90%). Inpatient HCLC followed by outpatient SAP therapy can provide a safe and effective means to rapidly reverse glucose toxicity and establish near-normal glycemic control in patients with newly diagnosed type 1 diabetes.
Walsh, Jessica A; McFadden, Molly; Woodcock, Jamie; Clegg, Daniel O; Helliwell, Philip; Dommasch, Erica; Gelfand, Joel M; Krueger, Gerald G; Duffin, Kristina Callis
2013-12-01
The Psoriasis Area and Severity Index (PASI) is considered the gold standard assessment tool for psoriasis severity, but PASI is limited by its complexity and insensitivity in people with mild psoriasis. We sought to evaluate the product of a Physician Global Assessment (PGA) and Body Surface Area (BSA) (PGAxBSA) as an alternative to PASI. Psoriasis severity was evaluated at 6-month intervals in participants of the Utah Psoriasis Initiative registry. Correlation coefficients were used to compare PGAxBSA with PASI and the Simplified PASI (SPASI). Between August 2008 and November 2010, 435 assessments were completed in 226 participants. The median PASI score was 3.2 (interquartile range 1.8-5.4) and the median BSA was 3.0% (interquartile range 1.0%-5.0%). PGAxBSA had higher correlations with PASI than SPASI (0.87 vs 0.76, P < .001). PGAxBSA also had higher correlations with a Global Patient Assessment of psoriasis severity (0.65) than both PASI (0.59, P < .001) and SPASI (0.51, P < .001). The use of PGAxBSA for measuring severe psoriasis and response to therapy is unclear, because most participants had mild to moderate psoriasis and data were not collected at predefined intervals in relation to therapy initiation. Interrater reliability was not assessed. PGAxBSA is a simple and sensitive instrument for measuring psoriasis severity. Copyright © 2013 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Long-term treatment of uterine fibroids with ulipristal acetate ☆.
Donnez, Jacques; Vázquez, Francisco; Tomaszewski, Janusz; Nouri, Kazem; Bouchard, Philippe; Fauser, Bart C J M; Barlow, David H; Palacios, Santiago; Donnez, Olivier; Bestel, Elke; Osterloh, Ian; Loumaye, Ernest
2014-06-01
To investigate the efficacy and safety of ulipristal acetate (UPA) for long-term treatment of symptomatic uterine fibroids. Repeated intermittent open-label UPA courses, each followed by randomized double-blind norethisterone acetate (NETA) or placebo. European clinical gynecology centers. Two hundred and nine women with symptomatic fibroids including heavy menstrual bleeding. Patients received up to four 3-month courses of UPA 10 mg daily, immediately followed by 10-day double-blind treatment with NETA (10 mg daily) or placebo. Amenorrhea, fibroid volume, endometrial histology. After the first UPA course, amenorrhea occurred in 79% of women, with median onset (from treatment start) of 4 days (interquartile range, 2-6 days). Median fibroid volume change was -45% (interquartile range, -66%; -25%). Amenorrhea rates were 89%, 88%, and 90% for the 131, 119, and 107 women who received treatment courses 2, 3, and 4, respectively. Median times to amenorrhea were 2, 3, and 3 days for treatment courses 2, 3, and 4, respectively. Median fibroid volume changes from baseline were -63%, -67%, and -72% after treatment courses 2, 3, and 4, respectively. All endometrial biopsies showed benign histology without hyperplasia; NETA did not affect fibroid volume or endometrial histology. Repeated 3-month UPA courses effectively control bleeding and shrink fibroids in patients with symptomatic fibroids. ClinicalTrials.gov (www.clinicaltrials.gov) registration numbers NCT01156857 (PEARL III) and NCT01252069 (PEARL III extension). Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Godah, Mohammad W; Abdul Khalek, Rima A; Kilzar, Lama; Zeid, Hiba; Nahlawi, Acile; Lopes, Luciane Cruz; Darzi, Andrea J; Schünemann, Holger J; Akl, Elie A
2016-12-01
Low- and middle-income countries adapt World Health Organization (WHO) guidelines instead of de novo development for financial, epidemiologic, sociopolitical, cultural, organizational, and other reasons. To systematically evaluate reported processes used in the adaptation of WHO guidelines for human immunodeficiency virus (HIV) and tuberculosis (TB). We searched three online databases/repositories: United States Agency for International Development (USAID) AIDS Support and Technical Resources - Sector One program (AIDSTAR-One) National Treatment Database; the AIDSspace Guideline Repository, and WHO Database of national HIV and TB guidelines. We assessed the rigor and quality of reported adaptation methodology using the ADAPTE process as benchmark. Of 170 eligible guidelines, only 32 (19%) reported documentation on the adaptation process. The median and interquartile range of the number of ADAPTE steps fulfilled by the eligible guidelines were 11.5 (10, 13.5) (out of 23 steps). The number of guidelines (out of 32 steps) fulfilling each ADAPTE step was 18 (interquartile range, 5-27). Seventeen of 32 guidelines (53%) met all steps relevant to the setup phase, whereas none met all steps relevant to the adaptation phase. The number of well-documented adaptation methodologies in national HIV and/or TB guidelines is very low. There is a need for the use of standardized and systematic framework for guideline adaptation and improved reporting of processes used. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Contini, D.; Donateo, A.; Belosi, F.; Grasso, F. M.; Santachiara, G.; Prodi, F.
2010-08-01
This work reports an analysis of the concentration, size distribution, and deposition velocity of atmospheric particles over snow and iced surfaces on the Nansen Ice Sheet (Antarctica). Measurements were performed using the eddy-correlation method at a remote site during the XXII Italian expedition of the National Research Program in Antarctica (PNRA) in 2006. The measurement system was based on a condensation particle counter (CPC) able to measure particles down to 9 nm in diameter with a 50% efficiency and a Differential Mobility Particle Sizer for evaluating particle size distributions from 11 to 521 nm diameter in 39 channels. A method based on postprocessing with digital filters was developed to take into account the effect of the slow time response of the CPC. The average number concentration was 1338 cm-3 (median, 978 cm-3; interquartile range, 435-1854 cm-3). Higher concentrations were observed at low wind velocities. Results gave an average deposition velocity of 0.47 mm/s (median, 0.19 mm/s; interquartile range, -0.21 -0.88 mm/s). Deposition increased with the friction velocity and was on average 0.86 mm/s during katabatic wind characterized by velocities higher than 4 m/s. Observed size distributions generally presented two distinct modes, the first at approximately 15-20 nm and the second (representing on average 70% of the total particles) at 60-70 nm. Under strong-wind conditions, the second mode dominated the average size distribution.
Changes in toe clearance during treadmill walking after long-duration spaceflight.
Miller, Christopher A; Peters, Brian T; Brady, Rachel R; Richards, Jason R; Ploutz-Snyder, Robert J; Mulavara, Ajitkumar P; Bloomberg, Jacob J
2010-10-01
Astronauts exhibit sensorimotor changes upon return from long-duration spaceflight that can result in altered gait kinematics and possibly an increased risk of tripping. Toe trajectory during locomotion is a precise motor control task involving both legs, thus providing a composite metric of locomotor control. The purpose of this study was to determine whether astronauts are at an increased risk of tripping after their return from long-duration spaceflight. This was accomplished by assessing the pre- to postflight changes in toe clearance during treadmill walking. Ten crewmembers walked on a treadmill while performing a visual-acuity task pre- and postflight. In the three subjects on whom landing day data were available, each exhibited a characteristic of increased tripping risk on landing day: either a decreased median toe clearance or an increased interquartile range (a measure of variance). For all crewmembers, toe clearance median and interquartile range were not significantly different from preflight for the other postflight sessions (the earliest being 1 d after landing). A follow-up analysis showed that changes in foot pitch, ankle dorsiflexion, and pelvis roll angles were significant predictors of changes in toe clearance. The landing-day observations indicated an increased risk of tripping, which may pose a hazard during locomotion immediately upon return to Earth, especially in an emergency scenario. However, tripping risk on subsequent days was not different than preflight. The joint angle analysis suggested that the crewmembers tried to reestablish their normal walking pattern postflight, instead of developing a new motor control strategy.
Fine particulate matter and risk of preterm birth in Connecticut in 2000-2006: a longitudinal study.
Pereira, Gavin; Belanger, Kathleen; Ebisu, Keita; Bell, Michelle L
2014-01-01
Several studies have examined associations between particulate matter with aerodynamic diameter of 2.5 µm or less (PM2.5) and preterm birth, but it is uncertain whether results were affected by individual predispositions (e.g., genetic factors, social conditions) that might vary considerably between women. We tested the hypothesis that a woman is at greater risk of preterm delivery when she has had elevated exposure to ambient PM2.5 during a pregnancy than when she has not by comparing pregnancies in the same woman. From 271,204 births, we selected 29,175 women who had vaginal singleton livebirths at least twice in Connecticut in 2000-2006 (n = 61,688 births). Analyses matched pregnancies to the same woman. Adjusted odds ratios per interquartile range (2.33-µg/m(3)) increase in PM2.5 in the first trimester, second trimester, third trimester, and whole pregnancy were 1.07 (95% confidence interval (CI): 1.00, 1.15), 0.96 (95% CI: 0.90, 1.03), 1.03 (95% CI: 0.97, 1.08), and 1.13 (95% CI: 1.01, 1.28), respectively. Among Hispanic women, the odds ratio per interquartile range increase in whole-pregnancy exposure was 1.31 (95% CI: 1.00, 1.73). Pregnancies with elevated PM2.5 exposure were more likely to result in preterm birth than were other pregnancies to the same woman at lower exposure. Associations were most pronounced in the first trimester and among Hispanic women.
Early Life Experiences and Telomere Length in Adult Rhesus Monkeys: An Exploratory Study
Schneper, Lisa M.; Brooks-Gunn, Jeanne; Notterman, Daniel A.; Suomi, Stephen J.
2016-01-01
Objective Child rearing environments have been associated with morbidity in adult rhesus monkeys. We examine whether such links are also seen with leukocyte telomere length. Methods To determine telomere length in leukocytes, blood was collected from 11 adult females aged seven to ten years who had been exposed to different rearing environments between birth and seven months. Four had been reared with their mothers in typical social groups comprised of other females, their offspring, and 1–2 adult males. The other seven had been reared in either small groups of peers or in individual cages with extensive peer interaction daily. After seven months, all shared a common environment. Results Telomere lengths were longer for those adults who had been reared with their mothers in social groups (median = 16.0 kb, interquartile range = 16.5–15.4) than for those who were reared without their mothers (median = 14.0 kb, interquartile range = 14.3–12.7; 2.2 kb/telomere difference, p<0.027). Conclusions This observation adds to emerging knowledge about early adverse child rearing conditions and their potential for influencing later morbidity. As newborns were randomly assigned to the mother or other rearing conditions, the findings are not confounded by other conditions that co-occur with adverse child rearing environments in humans (e.g., prenatal stress, nutrition and health as well as postnatal nutrition and negative life experiences over and above rearing conditions). PMID:27763985
Milner, Rowan J; Peyton, Jamie; Cooke, Kirsten; Fox, Leslie E; Gallagher, Alexander; Gordon, Patti; Hester, Juli
2005-10-01
To determine response rates and survival times for cats with lymphoma treated with the University of Wisconsin-Madison chemotherapy protocol. Retrospective study. 38 cats with lymphoma. Medical records were reviewed, and information on age, sex, breed, FeLV and FIV infection status, anatomic form, clinical stage, and survival time was obtained. Immunophenotyping was not performed. Mean +/- SD age of the cats was 10.9 +/- 4.4 years. Overall median survival time was 210 days (interquartile range, 90 to 657 days), and overall duration of first remission was 156 days (interquartile range, 87 to 316 days). Age, sex, anatomic form, and clinical stage were not significantly associated with duration of first remission or survival time. Eighteen of the 38 (47%) cats had complete remission, 14 (37%) had partial remission, and 6 (16%) had no response. Duration of first remission was significantly longer for cats with complete remission (654 days) than for cats with partial remission (114 days). Median survival time for cats with complete remission (654 days) was significantly longer than median survival time for cats with partial remission (122 days) and for cats with no response (11 days). Results suggested that a high percentage of cats with lymphoma will respond to treatment with the University of Wisconsin-Madison chemotherapy protocol. Age, sex, anatomic form, and clinical stage were not significantly associated with duration of first response or survival time, but initial response to treatment was.
Canadian veterinarians’ use of analgesics in cattle, pigs, and horses in 2004 and 2005
Hewson, Caroline J.; Dohoo, Ian R.; Lemke, Kip A.; Barkema, Herman W.
2007-01-01
Anecdotal evidence suggests that many veterinarians may not use analgesics in livestock for routine surgical procedures or painful disease states. To investigate this, we conducted a national mail survey of a random sample of 1431 Canadian veterinarians (response rate, 50.1%). Questions primarily concerned veterinarians’ analgesic usage for common surgeries and medical conditions in beef and dairy cattle, pigs, and horses, and attitudes toward pain management. More than 90% of veterinarians used analgesic drugs for equine surgeries, for cesarean section in sows and cows, and for bovine claw amputation and omentopexy. However, in these and other categories, the analgesics used were often inadequate, and many veterinarians did not give analgesics to young animals. When castrated, < 0.001% of piglets received analgesia, compared with 6.9% of beef calves and 18.7% of dairy calves ≤ 6 mo of age, 19.9% of beef calves and 33.2% of dairy calves > 6 mo of age, and 95.8% of horses. Respondents largely agreed that there are no long-acting, cost-effective analgesics available for use in livestock (median rating 8/10; interquartile range 4–9), and that the long or unknown withdrawal periods of some drugs outweighed the benefits of using them (median rating 7/10; interquartile range 4–9). The results indicate an urgent need for veterinarians to manage pain in livestock better. Continuing education would help, as would an increase in the number of approved, cost-effective analgesic drugs with known withdrawal periods. PMID:17334029
Ramler, Paul I; van den Akker, Thomas; Henriquez, Dacia D C A; Zwart, Joost J; van Roosmalen, Jos
2017-06-19
Postpartum hemorrhage remains the leading cause of maternal morbidity and mortality worldwide. Few population-based studies have examined the epidemiology of massive transfusion for postpartum hemorrhage. The aim of this study was to determine the incidence, management, and outcomes of women with postpartum hemorrhage who required massive transfusion in the Netherlands between 2004 and 2006. Data for all women from a gestational age of 20 weeks onwards who had postpartum hemorrhage requiring eight or more red blood cell concentrates were obtained from a nationwide population-based cohort study including all 98 hospitals with a maternity unit in the Netherlands. Three hundred twenty-seven women who had postpartum hemorrhage requiring massive transfusion were identified (massive transfusion rate 91 per 100,000 deliveries (95% confidence interval: 81-101)). The median blood loss was 4500 mL (interquartile range 3250-6000 mL) and the median number of red blood cell concentrates transfused was 11 units (interquartile range 9-16 units). Among women receiving massive transfusion, the most common cause of hemorrhage was uterine atony. Eighty-three women (25%) underwent hysterectomy, 227 (69%) were admitted to an intensive care unit, and three women died (case fatality rate 0,9%). The number of women in the Netherlands who had postpartum hemorrhage treated with massive transfusion was relatively high compared to other comparable settings. Evidence-based uniform management guidelines are necessary.