Tams, Stefan; Thatcher, Jason; Grover, Varun; Pak, Richard
2015-01-01
The ubiquity of instant messages and email notifications in contemporary work environments has opened a Pandora's Box. This box is filled with countless interruptions coming from laptops, smartphones, and other devices, all of which constantly call for employees' attention. In this interruption era, workplace stress is a pervasive problem. To examine this problem, the present study hypothesizes that the three-way interaction among the frequency with which interrupting stimuli appear, their salience, and employees' deficits in inhibiting attentional responses to them impacts mental workload perceptions, ultimately leading to stress. The study, further, probes a related form of self-efficacy as a potential suppressor of interruption-based stress. The study used a 2 (low vs. high frequency) × 2 (low vs. high salience) mixed model design. The 128 subjects completed a test of their inhibitory deficits and rated their mental workload perceptions and experiences of stress following a computer-based task. Inhibitory deficits and increased interruption salience can alter the perception of mental workload in contemporary work environments for the worse, but interruption self-efficacy can help offset any resulting interruption-based stress. This study extends the literatures on work interruptions as well as on stress and coping in the workplace.
46 CFR 111.81-1 - Outlet boxes and junction boxes; general.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fixture, wiring device, or similar item, including each separately installed connection and junction box... used. (d) As appropriate, each outlet-box or junction-box installation must meet the following...
ERIC Educational Resources Information Center
Huitema, Bradley E.; McKean, Joseph W.
2007-01-01
Regression models used in the analysis of interrupted time-series designs assume statistically independent errors. Four methods of evaluating this assumption are the Durbin-Watson (D-W), Huitema-McKean (H-M), Box-Pierce (B-P), and Ljung-Box (L-B) tests. These tests were compared with respect to Type I error and power under a wide variety of error…
30 CFR 75.815 - Disconnect devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... phase-to-phase voltage of the circuit in which they are installed, and for the full-load current of the... explosion-proof enclosures, must be capable of interrupting the full-load current of the circuit or designed and installed to cause the current to be interrupted automatically prior to the opening of the...
30 CFR 75.815 - Disconnect devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... phase-to-phase voltage of the circuit in which they are installed, and for the full-load current of the... explosion-proof enclosures, must be capable of interrupting the full-load current of the circuit or designed and installed to cause the current to be interrupted automatically prior to the opening of the...
An improved portmanteau test for autocorrelated errors in interrupted time-series regression models.
Huitema, Bradley E; McKean, Joseph W
2007-08-01
A new portmanteau test for autocorrelation among the errors of interrupted time-series regression models is proposed. Simulation results demonstrate that the inferential properties of the proposed Q(H-M) test statistic are considerably more satisfactory than those of the well known Ljung-Box test and moderately better than those of the Box-Pierce test. These conclusions generally hold for a wide variety of autoregressive (AR), moving averages (MA), and ARMA error processes that are associated with time-series regression models of the form described in Huitema and McKean (2000a, 2000b).
Series and parallel arc-fault circuit interrupter tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jay Dean; Fresquez, Armando J.; Gudgel, Bob
2013-07-01
While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by openingmore » the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.« less
Walsh, Kristin E; Chui, Michelle Anne; Kieser, Mara A; Williams, Staci M; Sutter, Susan L; Sutter, John G
2011-01-01
To explore community pharmacy technician workflow change after implementation of an automated robotic prescription-filling device. At an independent community pharmacy in rural Mayville, WI, pharmacy technicians were observed before and 3 months after installation of an automated robotic prescription-filling device. The main outcome measures were sequences and timing of technician workflow steps, workflow interruptions, automation surprises, and workarounds. Of the 77 and 80 observations made before and 3 months after robot installation, respectively, 17 different workflow sequences were observed before installation and 38 after installation. Average prescription filling time was reduced by 40 seconds per prescription with use of the robot. Workflow interruptions per observation increased from 1.49 to 1.79 (P = 0.11), and workarounds increased from 10% to 36% after robot use. Although automated prescription-filling devices can increase efficiency, workflow interruptions and workarounds may negate that efficiency. Assessing changes in workflow and sequencing of tasks that may result from the use of automation can help uncover opportunities for workflow policy and procedure redesign.
24 CFR 3280.208 - Smoke alarm requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... basement and must install at the factory an electrical junction box for the installation of this smoke... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... system must be mounted on an electrical outlet box and connected by a permanent wiring method to a...
Hot tap thermowell installation
NASA Technical Reports Server (NTRS)
Romero, C. A.
1971-01-01
System permits valve housings or other fillings to be installed in live steam lines or water pipes without interrupting their operation, thus eliminating current tapping restrictions. Two basic assemblies for installation under pressure are described.
The Carnegie Quick Deploy Box (QDB) for use with broadband and intermediate period sensors
NASA Astrophysics Data System (ADS)
Wagner, L. S.; Roman, D.; Bartholomew, T.; Golden, S.; Schleigh, B.
2017-12-01
Recent data processing advances have increased the call for dense recordings of teleseismic data. However, traditional broadband field installations typically comprise 1) a sensor vault 2) a field box to hold the recording and power systems, and 3) a solar panel mount. The construction of these installations is time consuming and requires bulky construction materials, limiting the number of stations that can be installed from a single vehicle without repeated trips to a storage facility. Depending on the deployment location, watertight containers for both vault and field box can be difficult to find, resulting in a loss of data due to flooding. Recent technological improvements have made possible the direct burial of sensors (no vault required) and a reduction in the size of the solar panels needed to run a station. With support from the Brinson Foundation, we take advantage of these advances to create a field box/shipping container that will greatly simplify these types of seismic deployments. The goal of the Carnegie Quick Deploy Box (QDB) is to have everything needed for an intermediate period station install (except battery and shovel) contained in a single box for shipment, and to be able to leave everything (except the shovel) in that box when the station is deployed. The box is small enough ( 13"x13"x21") and lightweight enough (< 35 lbs) to be checked as airline luggage. The solar panel mount can be attached securely to the top of the box, but it can also be pole mounted with U-bolts or hose clamps. The sensor can be direct-buried. The sensor cable and solar panel cable plug into watertight bulkhead-fitted plugs on the outside of the box that are in turn plugged into the digitizer and power regulator inside the box. Our prototype boxes (Pelican Cases) have proved watertight when submerged for days. This equipment has been tested in Alaska in winter and Nicaragua in summer without failure due to flooding or power. The cost for parts for a single box (not including sensor cable, sensor, or digitizer) is $500. The setup is simple, and can be completed in a matter of minutes once the sensor is installed. QDBs such as ours will make possible a dramatic increase in the number of stations that can be installed, while also significantly decreasing the cost of deployment per station by reducing vehicle time, fuel, personnel time, and shipping costs.
Walsh, Kristin E.; Chui, Michelle Anne; Kieser, Mara A.; Williams, Staci M.; Sutter, Susan L.; Sutter, John G.
2012-01-01
Objective To explore community pharmacy technician workflow change after implementation of an automated robotic prescription-filling device. Methods At an independent community pharmacy in rural Mayville, WI, pharmacy technicians were observed before and 3 months after installation of an automated robotic prescription-filling device. The main outcome measures were sequences and timing of technician workflow steps, workflow interruptions, automation surprises, and workarounds. Results Of the 77 and 80 observations made before and 3 months after robot installation, respectively, 17 different workflow sequences were observed before installation and 38 after installation. Average prescription filling time was reduced by 40 seconds per prescription with use of the robot. Workflow interruptions per observation increased from 1.49 to 1.79 (P = 0.11), and workarounds increased from 10% to 36% after robot use. Conclusion Although automated prescription-filling devices can increase efficiency, workflow interruptions and workarounds may negate that efficiency. Assessing changes in workflow and sequencing of tasks that may result from the use of automation can help uncover opportunities for workflow policy and procedure redesign. PMID:21896459
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature monitoring device shall be installed in the fire box or in the ductwork immediately downstream of the fire box in a position before any substantial heat exchange occurs. (ii) Where a catalytic incinerator is used, temperature monitoring devices shall be installed in the gas stream immediately before...
Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baggu, Murali M; Smith, Kandler A; Friedl, Andrew
A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS withmore » little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.« less
NASA Technical Reports Server (NTRS)
Bachtell, E. E.; Thiemet, W. F.; Morosow, G.
1987-01-01
To demonstrate the design and integration of a reflective mesh surface to a deployable truss structure, a mesh reflector was installed on a 15 foot box truss cube. The specific features demonstrated include: (1) sewing seams in reflective mesh; (2) mesh stretching to desired preload; (3) installation of surface tie cords; (4) installation of reflective surface on truss; (5) setting of reflective surface; (6) verification of surface shape/accuracy; (7) storage and deployment; (8) repeatability of reflector surface; and (9) comparison of surface with predicted shape using analytical methods developed under a previous task.
Evaluation of bike boxes at signalized intersections.
DOT National Transportation Integrated Search
2011-01-01
This report presents a before-after study of bike boxes at 10 signalized intersections in Portland, Oregon. The bike boxes, also known as advanced stop lines or advanced stop boxes, were installed to increase visibility of cyclists and reduce conflic...
Shave, Megan E; Lindell, Catherine A
2017-01-01
Nest boxes for predators in agricultural regions are an easily implemented tool to improve local habitat quality with potential benefits for both conservation and agriculture. The potential for nest boxes to increase raptor populations in agricultural regions is of particular interest given their positions as top predators. This study examined the effects of cherry orchard nest boxes on the local breeding population of a declining species, the American Kestrel (Falco sparverius), in a fruit-growing region of Michigan. During the 2013-2016 study, we added a total of 23 new nest boxes in addition to 24 intact boxes installed previously; kestrels used up to 100% of our new boxes each season. We conducted temporally-replicated surveys along four roadside transects divided into 1.6 km × 500 m sites. We developed a multi-season occupancy model under a Bayesian framework and found that nest boxes had strong positive effects on first-year site occupancy, site colonization, and site persistence probabilities. The estimated number of occupied sites increased between 2013 and 2016, which correlated with the increase in number of sites with boxes. Kestrel detections decreased with survey date but were not affected by time of day or activity at the boxes themselves. These results indicate that nest boxes determined the presence of kestrels at our study sites and support the conclusion that the local kestrel population is likely limited by nest site availability. Furthermore, our results are highly relevant to the farmers on whose properties the boxes were installed, for we can conclude that installing a nest box in an orchard resulted in a high probability of kestrels occupying that orchard or the areas adjacent to it.
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
...) that BOX may provide. The one time setup and ongoing monthly fees associated with Participant.... Setup (one time charge for new BOX Participants) Installation $350 Cross Connect per T-1 250 Cross... proposed fees and credits for transactions on BOX offset one another in any particular transaction. The...
46 CFR 183.354 - Battery installations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Battery installations. 183.354 Section 183.354 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely...
46 CFR 183.354 - Battery installations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Battery installations. 183.354 Section 183.354 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely...
46 CFR 183.354 - Battery installations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Battery installations. 183.354 Section 183.354 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely...
46 CFR 183.354 - Battery installations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Battery installations. 183.354 Section 183.354 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely...
46 CFR 183.354 - Battery installations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Battery installations. 183.354 Section 183.354 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely...
46 CFR 129.356 - Battery installations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Battery installations. 129.356 Section 129.356 Shipping... INSTALLATIONS Power Sources and Distribution Systems § 129.356 Battery installations. (a) Large. Each large battery-installation must be located in a locker, room, or enclosed box dedicated solely to the storage of...
46 CFR 129.356 - Battery installations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Battery installations. 129.356 Section 129.356 Shipping... INSTALLATIONS Power Sources and Distribution Systems § 129.356 Battery installations. (a) Large. Each large battery-installation must be located in a locker, room, or enclosed box dedicated solely to the storage of...
46 CFR 129.356 - Battery installations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Battery installations. 129.356 Section 129.356 Shipping... INSTALLATIONS Power Sources and Distribution Systems § 129.356 Battery installations. (a) Large. Each large battery-installation must be located in a locker, room, or enclosed box dedicated solely to the storage of...
46 CFR 129.356 - Battery installations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Battery installations. 129.356 Section 129.356 Shipping... INSTALLATIONS Power Sources and Distribution Systems § 129.356 Battery installations. (a) Large. Each large battery-installation must be located in a locker, room, or enclosed box dedicated solely to the storage of...
46 CFR 129.356 - Battery installations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Battery installations. 129.356 Section 129.356 Shipping... INSTALLATIONS Power Sources and Distribution Systems § 129.356 Battery installations. (a) Large. Each large battery-installation must be located in a locker, room, or enclosed box dedicated solely to the storage of...
V/STOL tilt rotor research aircraft. Volume 3: Ship 2 instrumentation
NASA Technical Reports Server (NTRS)
1978-01-01
Information covering sensor cables, sensor installation, and sensor calibration for the XV-15 aircraft number 2 is included. For each junction box (J-box) designation there is a schematic of the J-box disconnect harness, instrumentation worksheets which show sensor location, and calibration data sheets for each sensor associated with that J-box. An index of measurement data codes to J-box locations is given in a table. Cross references are given.
V/STOL tilt rotor research aircraft. Volume 2: Ship 1 instrumentation
NASA Technical Reports Server (NTRS)
1978-01-01
Information covering sensor cables, sensor installation, and sensor calibration for the XV-15 aircraft number 1 is included. For each junction box (J-box) designation there is a schematic of the J-box disconnect harness instrumentation worksheets which show sensor location, and calibration data sheets for each sensor associated with that J-box. An index of measurement item codes to J-box locations is given in a table. Cross references are given.
46 CFR 120.354 - Battery installations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Battery installations. 120.354 Section 120.354 Shipping... and Distribution Systems § 120.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries...
46 CFR 120.354 - Battery installations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Battery installations. 120.354 Section 120.354 Shipping... and Distribution Systems § 120.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries...
46 CFR 120.354 - Battery installations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Battery installations. 120.354 Section 120.354 Shipping... and Distribution Systems § 120.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries...
46 CFR 120.354 - Battery installations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Battery installations. 120.354 Section 120.354 Shipping... and Distribution Systems § 120.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries...
46 CFR 120.354 - Battery installations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Battery installations. 120.354 Section 120.354 Shipping... and Distribution Systems § 120.354 Battery installations. (a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries...
Smart home in a box: usability study for a large scale self-installation of smart home technologies.
Hu, Yang; Tilke, Dominique; Adams, Taylor; Crandall, Aaron S; Cook, Diane J; Schmitter-Edgecombe, Maureen
2016-07-01
This study evaluates the ability of users to self-install a smart home in a box (SHiB) intended for use by a senior population. SHiB is a ubiquitous system, developed by the Washington State University Center for Advanced Studies in Adaptive Systems (CASAS). Participants involved in this study are from the greater Palouse region of Washington State, and there are 13 participants in the study with an average age of 69.23. The SHiB package, which included several different types of components to collect and transmit sensor data, was given to participants to self-install. After installation of the SHiB, the participants were visited by researchers for a check of the installation. The researchers evaluated how well the sensors were installed and asked the resident questions about the installation process to help improve the SHiB design. The results indicate strengths and weaknesses of the SHiB design. Indoor motion tracking sensors are installed with high success rate, low installation success rate was found for door sensors and setting up the Internet server.
Smart home in a box: usability study for a large scale self-installation of smart home technologies
Hu, Yang; Tilke, Dominique; Adams, Taylor; Crandall, Aaron S.; Schmitter-Edgecombe, Maureen
2017-01-01
This study evaluates the ability of users to self-install a smart home in a box (SHiB) intended for use by a senior population. SHiB is a ubiquitous system, developed by the Washington State University Center for Advanced Studies in Adaptive Systems (CASAS). Participants involved in this study are from the greater Palouse region of Washington State, and there are 13 participants in the study with an average age of 69.23. The SHiB package, which included several different types of components to collect and transmit sensor data, was given to participants to self-install. After installation of the SHiB, the participants were visited by researchers for a check of the installation. The researchers evaluated how well the sensors were installed and asked the resident questions about the installation process to help improve the SHiB design. The results indicate strengths and weaknesses of the SHiB design. Indoor motion tracking sensors are installed with high success rate, low installation success rate was found for door sensors and setting up the Internet server. PMID:28936390
Molded polymer solar water heater
Bourne, Richard C.; Lee, Brian E.
2004-11-09
A solar water heater has a rotationally-molded water box and a glazing subassembly disposed over the water box that enhances solar gain and provides an insulating air space between the outside environment and the water box. When used with a pressurized water system, an internal heat exchanger is integrally molded within the water box. Mounting and connection hardware is included to provide a rapid and secure method of installation.
2013-01-01
Background In March, 2007, a black box warning was issued by the Food and Drug Administration (FDA) to use the lowest possible erythropoiesis-stimulating agents (ESA) doses for treatment of anemia associated with renal disease. The goal is to determine if a change in ESA use was observed following the warning among US dialysis patients. Methods ESA therapy was examined from September 2004 through August 2009 (thirty months before and after the FDA black box warning) among adult Medicare hemodialysis patients. An interrupted time series model assessed the impact of the warnings. Results The FDA black box warning did not appear to influence ESA prescribing among the overall dialysis population. However, significant declines in ESA therapy after the FDA warnings were observed for selected populations. Patients with a hematocrit ≥36% had a declining month-to-month trend before (−164 units/week, p = <0.0001) and after the warnings (−80 units/week, p = .001), and a large drop in ESA level immediately after the black box (−4,744 units/week, p = <.0001). Not-for-profit facilities had a declining month-to-month trend before the warnings (−90 units/week, p = .009) and a large drop in ESA dose immediately afterwards (−2,487 units/week, p = 0.015). In contrast, for-profit facilities did not have a significant change in ESA prescribing. Conclusions ESA therapy had been both profitable for providers and controversial regarding benefits for nearly two decades. The extent to which a FDA black box warning highlighting important safety concerns influenced use of ESA therapy among nephrologists and dialysis providers was unknown. Our study found no evidence of changes in ESA prescribing for the overall dialysis population resulting from a FDA black box warning. PMID:23927675
14 CFR 121.705 - Mechanical interruption summary report.
Code of Federal Regulations, 2013 CFR
2013-01-01
... § 121.703. (b) The number of engines removed prematurely because of malfunction, failure or defect, listed by make and model and the aircraft type in which it was installed. (c) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed...
14 CFR 121.705 - Mechanical interruption summary report.
Code of Federal Regulations, 2012 CFR
2012-01-01
... § 121.703. (b) The number of engines removed prematurely because of malfunction, failure or defect, listed by make and model and the aircraft type in which it was installed. (c) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed...
14 CFR 121.705 - Mechanical interruption summary report.
Code of Federal Regulations, 2014 CFR
2014-01-01
... § 121.703. (b) The number of engines removed prematurely because of malfunction, failure or defect, listed by make and model and the aircraft type in which it was installed. (c) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed...
14 CFR 121.705 - Mechanical interruption summary report.
Code of Federal Regulations, 2011 CFR
2011-01-01
... § 121.703. (b) The number of engines removed prematurely because of malfunction, failure or defect, listed by make and model and the aircraft type in which it was installed. (c) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed...
Griffiths, Stephen R; Rowland, Jessica A; Briscoe, Natalie J; Lentini, Pia E; Handasyde, Kathrine A; Lumsden, Linda F; Robert, Kylie A
2017-01-01
Thermal properties of tree hollows play a major role in survival and reproduction of hollow-dependent fauna. Artificial hollows (nest boxes) are increasingly being used to supplement the loss of natural hollows; however, the factors that drive nest box thermal profiles have received surprisingly little attention. We investigated how differences in surface reflectance influenced temperature profiles of nest boxes painted three different colors (dark-green, light-green, and white: total solar reflectance 5.9%, 64.4%, and 90.3% respectively) using boxes designed for three groups of mammals: insectivorous bats, marsupial gliders and brushtail possums. Across the three different box designs, dark-green (low reflectance) boxes experienced the highest average and maximum daytime temperatures, had the greatest magnitude of variation in daytime temperatures within the box, and were consistently substantially warmer than light-green boxes (medium reflectance), white boxes (high reflectance), and ambient air temperatures. Results from biophysical model simulations demonstrated that variation in diurnal temperature profiles generated by painting boxes either high or low reflectance colors could have significant ecophysiological consequences for animals occupying boxes, with animals in dark-green boxes at high risk of acute heat-stress and dehydration during extreme heat events. Conversely in cold weather, our modelling indicated that there are higher cumulative energy costs for mammals, particularly smaller animals, occupying light-green boxes. Given their widespread use as a conservation tool, we suggest that before boxes are installed, consideration should be given to the effect of color on nest box temperature profiles, and the resultant thermal suitability of boxes for wildlife, particularly during extremes in weather. Managers of nest box programs should consider using several different colors and installing boxes across a range of both orientations and shade profiles (i.e., levels of canopy cover), to ensure target animals have access to artificial hollows with a broad range of thermal profiles, and can therefore choose boxes with optimal thermal conditions across different seasons.
Surface reflectance drives nest box temperature profiles and thermal suitability for target wildlife
Rowland, Jessica A.; Briscoe, Natalie J.; Lentini, Pia E.; Handasyde, Kathrine A.; Lumsden, Linda F.; Robert, Kylie A.
2017-01-01
Thermal properties of tree hollows play a major role in survival and reproduction of hollow-dependent fauna. Artificial hollows (nest boxes) are increasingly being used to supplement the loss of natural hollows; however, the factors that drive nest box thermal profiles have received surprisingly little attention. We investigated how differences in surface reflectance influenced temperature profiles of nest boxes painted three different colors (dark-green, light-green, and white: total solar reflectance 5.9%, 64.4%, and 90.3% respectively) using boxes designed for three groups of mammals: insectivorous bats, marsupial gliders and brushtail possums. Across the three different box designs, dark-green (low reflectance) boxes experienced the highest average and maximum daytime temperatures, had the greatest magnitude of variation in daytime temperatures within the box, and were consistently substantially warmer than light-green boxes (medium reflectance), white boxes (high reflectance), and ambient air temperatures. Results from biophysical model simulations demonstrated that variation in diurnal temperature profiles generated by painting boxes either high or low reflectance colors could have significant ecophysiological consequences for animals occupying boxes, with animals in dark-green boxes at high risk of acute heat-stress and dehydration during extreme heat events. Conversely in cold weather, our modelling indicated that there are higher cumulative energy costs for mammals, particularly smaller animals, occupying light-green boxes. Given their widespread use as a conservation tool, we suggest that before boxes are installed, consideration should be given to the effect of color on nest box temperature profiles, and the resultant thermal suitability of boxes for wildlife, particularly during extremes in weather. Managers of nest box programs should consider using several different colors and installing boxes across a range of both orientations and shade profiles (i.e., levels of canopy cover), to ensure target animals have access to artificial hollows with a broad range of thermal profiles, and can therefore choose boxes with optimal thermal conditions across different seasons. PMID:28472147
77 FR 11416 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-27
.... This proposed AD would require modifying COS boxes by installing new brackets, stiffeners, and hardware... installing new brackets, stiffeners, and hardware (bolts, washers, and nuts) as needed. FAA's Determination...
Navigating protected genomics data with UCSC Genome Browser in a Box.
Haeussler, Maximilian; Raney, Brian J; Hinrichs, Angie S; Clawson, Hiram; Zweig, Ann S; Karolchik, Donna; Casper, Jonathan; Speir, Matthew L; Haussler, David; Kent, W James
2015-03-01
Genome Browser in a Box (GBiB) is a small virtual machine version of the popular University of California Santa Cruz (UCSC) Genome Browser that can be run on a researcher's own computer. Once GBiB is installed, a standard web browser is used to access the virtual server and add personal data files from the local hard disk. Annotation data are loaded on demand through the Internet from UCSC or can be downloaded to the local computer for faster access. Software downloads and installation instructions are freely available for non-commercial use at https://genome-store.ucsc.edu/. GBiB requires the installation of open-source software VirtualBox, available for all major operating systems, and the UCSC Genome Browser, which is open source and free for non-commercial use. Commercial use of GBiB and the Genome Browser requires a license (http://genome.ucsc.edu/license/). © The Author 2014. Published by Oxford University Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bronfman, B. H.
Time-series analysis provides a useful tool in the evaluation of public policy outputs. It is shown that the general Box and Jenkins method, when extended to allow for multiple interrupts, enables researchers simultaneously to examine changes in drift and level of a series, and to select the best fit model for the series. As applied to urban renewal allocations, results show significant changes in the level of the series, corresponding to changes in party control of the Executive. No support is given to the ''incrementalism'' hypotheses as no significant changes in drift are found.
Cistern and planter box monitoring in Camden, NJ revisited
The Camden County Municipal Utilities Authority installed green infrastructure Stormwater Control Measures at multiple locations around the city of Camden, NJ. The Stormwater Control Measures include raised downspout planter boxes and cisterns. EPA is monitoring a subset of the ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemonds, David Preston
A breech lock for a glove box is provided that may be used to transfer one or more items into the glove box. The breech lock can be interchangeably installed in place of a plug, glove, or other device in a port or opening of a glove box. Features are provided to aid the removal of items from the breech lock by a gloved operator. The breech lock can be reused or, if needed, can be replaced with a plug, glove, or other device at the port or opening of the glove box.
11. SIDE VIEW OF INSTALLATION OF A CONTINUOUS ROTARYTUBE HYDROFLUORINATOR ...
11. SIDE VIEW OF INSTALLATION OF A CONTINUOUS ROTARY-TUBE HYDROFLUORINATOR LOCATED IN ROOM 146. THE HYDROFLUORINATOR IS BEING INSTALLED INSIDE A GLOVE BOX. HYDROFLUORINATION CONVERTED PLUTONIUM OXIDE TO PLUTONIUM TETRAFLUORIDE. (1/11/62) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
Installation of C-6533(XE-2)/ARC ICS in UH-1H helicopter
NASA Astrophysics Data System (ADS)
Hnat, J. A.
1980-07-01
This report documents the results of the installation of the C-6533(XE-2)/ARC ICS in UH-1H helicopter. Installation was performed at the AEL, Inc., Monmouth County Airport facility. Design of each installation was coordinated and approved by the Government. The mechanical and electrical installation drawings for the helicopter are attached as Appendix A of this report. The new ICS system consisted of new cabling, new intercoms and helmets rewired with new microphones. All four crew stations of the helicopter were reconfigured with the new system. Existing cabling for the standard ICS system remained in the aircraft but was securely stowed for later restoration of the aircraft. The helmets (4) were rewired using separate jacks for headphones and microphone lines. Transmit and receive cables were installed in the aircraft with a minimum separation of one inch between cables. A junction box was fabricated and installed on the aft end of the console to house the fan-out terminal strips. Transmit and receive lines' separation was maintained in the junction box. During the test phase the onboard radios were used with the new ICS system.
30 CFR 75.1600-1 - Communication facilities; main portals; installation requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., and shall be installed either in a building or in a box-like structure designed to protect the facilities from damage by inclement weather. At least one of these communication facilities shall be at a...
30 CFR 75.1600-1 - Communication facilities; main portals; installation requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., and shall be installed either in a building or in a box-like structure designed to protect the facilities from damage by inclement weather. At least one of these communication facilities shall be at a...
30 CFR 75.1600-1 - Communication facilities; main portals; installation requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., and shall be installed either in a building or in a box-like structure designed to protect the facilities from damage by inclement weather. At least one of these communication facilities shall be at a...
30 CFR 75.1600-1 - Communication facilities; main portals; installation requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., and shall be installed either in a building or in a box-like structure designed to protect the facilities from damage by inclement weather. At least one of these communication facilities shall be at a...
30 CFR 75.1600-1 - Communication facilities; main portals; installation requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and shall be installed either in a building or in a box-like structure designed to protect the facilities from damage by inclement weather. At least one of these communication facilities shall be at a...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
.... Repeating this step for other periods produces a series of market basket levels over time. Dividing an index..., P.O. Box 8010, Baltimore, MD 21244-1850. Please allow sufficient time for mailed comments to be...); interrupted stays; and a per treatment adjustment for patients who undergo ECT. A complete discussion of the...
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2011 CFR
2011-01-01
... reported under § 91.1415. (b) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed. Propeller featherings for training, demonstration...
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2013 CFR
2013-01-01
... reported under § 91.1415. (b) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed. Propeller featherings for training, demonstration...
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2012 CFR
2012-01-01
... reported under § 91.1415. (b) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed. Propeller featherings for training, demonstration...
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2014 CFR
2014-01-01
... reported under § 91.1415. (b) The number of propeller featherings in flight, listed by type of propeller and engine and aircraft on which it was installed. Propeller featherings for training, demonstration...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
Performance and Health Test Procedure for Grid Energy Storage Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baggu, Murali M; Smith, Kandler A; Friedl, Andrew
A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with littlemore » modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.« less
Payload bay atmospheric vent airflow testing at the Vibration and Acoustic Test Facility
NASA Technical Reports Server (NTRS)
Johnston, James D., Jr.
1988-01-01
Several concerns related to venting the Space Shuttle Orbiter payload bay during launch led to laboratory experiments with a flight-type vent box installed in the wall of a subsonic wind tunnel. This report describes the test setups and procedures used to acquire data for characterization of airflow through the vent box and acoustic tones radiated from the vent-box cavity. A flexible boundary-layer spoiler which reduced the vent-tone amplitude is described.
DOT National Transportation Integrated Search
1991-01-01
During the construction of the I-295 cable-stayed bridge, an extensive array of mechanical strain gage points were installed in sections of the box girders, pylons, and piers. At each instrumented box girder section, five longitudinal gages were plac...
Installation and Testing Instructions for the Sandia Automatic Report Generator (ARG).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clay, Robert L.
Robert L. CLAY Sandia National Laboratories P.O. Box 969 Livermore, CA 94551, U.S.A. rlclay@sandia.gov In this report, we provide detailed and reproducible installation instructions of the Automatic Report Generator (ARG), for both Linux and macOS target platforms.
DOT National Transportation Integrated Search
2014-08-01
This report describes the instrumentation and data acquisition for a continuous curved steel box-girder composite bridge in : Connecticut. The computer-based remote monitoring system was installed in 2001, with accelerometers, tilt meters and : tempe...
Cryogenic distribution box for Fermi National Accelerator Laboratory
NASA Astrophysics Data System (ADS)
Svehla, M. R.; Bonnema, E. C.; Cunningham, E. K.
2017-12-01
Meyer Tool & Mfg., Inc (Meyer Tool) of Oak Lawn, Illinois is manufacturing a cryogenic distribution box for Fermi National Accelerator Laboratory (FNAL). The distribution box will be used for the Muon-to-electron conversion (Mu2e) experiment. The box includes twenty-seven cryogenic valves, two heat exchangers, a thermal shield, and an internal nitrogen separator vessel, all contained within a six-foot diameter ASME coded vacuum vessel. This paper discusses the design and manufacturing processes that were implemented to meet the unique fabrication requirements of this distribution box. Design and manufacturing features discussed include: 1) Thermal strap design and fabrication, 2) Evolution of piping connections to heat exchangers, 3) Nitrogen phase separator design, 4) ASME code design of vacuum vessel, and 5) Cryogenic valve installation.
Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for
NASA Technical Reports Server (NTRS)
Denson, Erik C.
2014-01-01
This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.
2. VIEW OF INTERIOR, EAST SIDE (SIDE A) OF BUILDING ...
2. VIEW OF INTERIOR, EAST SIDE (SIDE A) OF BUILDING 883. INSTALLATION OF ROLLING MILLS AND MOLTEN SALT BATH EQUIPMENT FOR DEPLETED URANIUM FABRICATION. THE CRANE NEAR THE CEILING WAS USED TO INSTALL THE EQUIPMENT. BOXES ON THE FLOOR CONTAINED EQUIPMENT TO BE INSTALLED. (1/23/57) - Rocky Flats Plant, Uranium Rolling & Forming Operations, Southeast section of plant, southeast quadrant of intersection of Central Avenue & Eighth Street, Golden, Jefferson County, CO
Numerical modeling of high-voltage circuit breaker arcs and their interraction with the power system
NASA Astrophysics Data System (ADS)
Orama, Lionel R.
In this work the interaction between series connected gas and vacuum circuit breaker arcs has been studied. The breakdown phenomena in vacuum interrupters during the post arc current period have been of special interest. Numerical models of gas and vacuum arcs were developed in the form of black box models. Especially, the vacuum post arc model was implemented by combining the existing transition model with an ion density function and expressions for the breakdown mechanisms. The test series studied reflect that for electric fields on the order of 10sp7V/m over the anode, the breakdown of the vacuum gap can result from a combination of both thermal and electrical stresses. For a particular vacuum device, the vacuum model helps to find the interruption limits of the electric field and power density over the anode. The series connection of gas and vacuum interrupters always performs better than the single gas device. Moreover, to take advantage of the good characteristics of both devices, the time between the current zero crossing in each interrupter can be changed. This current zero synchronization is controlled by changing the capacitance in parallel to the gas device. This gas/vacuum interrupter is suitable for interruption of very stressful short circuits in which the product of the dI/dt before current zero and the dV/dt after current zero is very high. Also, a single SF6 interrupter can be replaced by an air circuit breaker of the same voltage rating in series with a vacuum device without compromising the good performance of the SF6 device. Conceptually, a series connected vacuum device can be used for high voltage applications with equal distribution of electrical stresses between the individual interrupters. The equalization can be made by a sequential opening of the individual contact pairs, beginning with the interruptors that are closer to ground potential. This could eliminate the use of grading capacitors.
Field performance of timber bridges. 11, Spearfish Creek stress-laminated box-beam bridge
J. P. Wacker; M. A. Ritter; K. Stanfill-McMillan
The Spearfish Creek bridge was constructed in 1992 in Spearfish, South Dakota. It is a single-span, stress-laminated, box-beam superstructure. Performance of the bridge is being monitored for 5 years, beginning at installation. This report summarizes results for the first 3-1/2 years of monitoring and includes information on the design, construction, and field...
On becoming "Wide-Awake": Artful Re-Search and Co-Creative Process as Teacher Development
ERIC Educational Resources Information Center
Mantas, Kathy; Di Rezze, Gianna
2011-01-01
In this essay we reference a co-creative art installation entitled Box-ing In/Out (Di Rezze & Mantas, 2006; Mantas, 2004). Through this collaborative project we describe how artful re-search and the co-creative process can help teachers access and reframe tacit understandings of teaching and learning. We argue that the personal meaning making,…
NASA's Orbital Debris Conjuction Assessment and Collision Avoidance Strategy
NASA Technical Reports Server (NTRS)
Gavin, Richard T.
2010-01-01
NASA has successfully used debris avoidance maneuvers to protect our spacecraft for more than 20 . years. This process which started out using parametric data and maneuver boxes has seen considerable evolution and now allows us to continue nominal operations for all but the most threatening objects. This has greatly reduced the interruptions to the critical mission objectives being pursued by NASA s Space Station, Space Shuttle, and robotic satellites.
Cook, Diane J; Crandall, Aaron S; Thomas, Brian L; Krishnan, Narayanan C
2013-07-01
While the potential benefits of smart home technology are widely recognized, a lightweight design is needed for the benefits to be realized at a large scale. We introduce the CASAS "smart home in a box", a lightweight smart home design that is easy to install and provides smart home capabilities out of the box with no customization or training. We discuss types of data analysis that have been performed by the CASAS group and can be pursued in the future by using this approach to designing and implementing smart home technologies.
Information technology: opening the box.
Nussbaum, G M
1998-09-01
If you thought managed care was a tough nut to crack, wait until you have to start making decisions about your organization's information technology (IT). Information systems are complex and expensive, they can take years to implement, and, once installed, they need costly and regular upgrades. But for a contemporary clinical organization to function, this technology is as essential as power and water. For many years, information technology was seen as a black box, impenetrable and beyond real understanding. If done with knowledge and care, however, cracking the box opens up possibilities, not ruin.
14 CFR 29.812 - Emergency lighting.
Code of Federal Regulations, 2010 CFR
2010-01-01
... lighting system, they may be recharged from the rotorcraft's main electrical power system provided the... power supply independent of the main lighting system must be installed to— (1) Illuminate each passenger... upon interruption of the rotorcraft's normal electric power. (d) Any means required to assist the...
Morkem, Rachael; Williamson, Tyler; Patten, Scott; Queenan, John A; Wong, Sabrina T; Manca, Donna; Barber, David
2017-09-01
The purpose of this study was to describe the trends and patterns of antidepressant (AD) prescribing to children and adolescents in Canadian primary care before and after the black-box warning in 2004. Prescription data from the Canadian Primary Care Sentinel Surveillance Network, a repository of primary care data on over 1 million patients, was used to analyze AD prescribing to children (8-11 y) and adolescents (12-18 y) between 2000 and 2014. Interrupted time series analyses were used to assess the impact of the 2004 black-box warning on the prescribing levels of ADs. The 2004 black-box warning had a significant and immediate effect on the prescribing of AD. However, this drop was not sustained, and 5 years after the advisory AD prescribing rates reversed direction and started to rise. Selective serotonin reuptake inhibitors dominated as the most common AD prescribed throughout the study period, increasing from 66% prior to the black-box warning to 83.12% after 2009. The black-box warning effectively reduced AD prescribing in primary care for approximately 5 years before a reversal back to a positive rate of prescribing. This rebounding could reflect an emerging consensus about the trade-off in risks and benefits. Copyright © 2017 John Wiley & Sons, Ltd.
Viewing boxes: a survey in diagnostic radiology departments of Moroccan hospitals.
Bentayeb, F; Nfaoiu, K; Basraoui, O; Azevedo, A C P
2010-10-01
This work consists on a survey of the performance of viewing boxes installed in diagnostic radiology departments and included several aspects: checking the illuminance of the diagnostic rooms where the viewing boxes are located as well as the viewing boxes luminance levels and homogeneity. Seven hospitals took part in the survey, being three in the city of Casablanca and four in Rabat. A total of 136 viewing boxes and 18 diagnostic rooms have been checked. It was found that one diagnostic room works under normal conditions and that 80% of the viewing boxes present luminance levels below the international recommendations and the homogeneity is inadequate in 85%. Some simple and cheap initiatives can be performed in these departments to increase luminance and improve homogeneity levels such as cleaning and bulbs replacement. Copyright © 2009 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
1980-03-01
replacement of existing breaker boxes with preassembled meter sockets and disconnect switches. At Fort Eustis, the electric meters were also provided...entered a common box were found to be installed on the wrong side. The latter problem was a result of improper wiring during construction which had not...o ’t i thi v 4k mh i Ae n1 r, ow it k ’ips As Ii~’ !I rt ~’ o~w t hs e aIo , 1kwh ’liuensl Mos ’ ilowwI kmit’ one .%%lok isnh,’s no ______Alt_10 _00
77 FR 60331 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
... (NLG) retraction. This proposed AD would require installing a power interruption protection circuit for... unlocking and/or retraction of the NLG, which, while on the ground, could result in injury to ground... A320 aeroplane was preparing to initiate taxi, when an uncommanded nose landing gear (NLG) retraction...
Behavioral Correlates of System Operational Readiness (SOR): Summary of Workshop Proceedings.
1983-10-01
1978) time series ARIMA models Use ARIMA models for (Box & Jenkins, 1976) interrupted time series Stage 7. Interpretation 7.1 Formatting and re...This report describes a 2-day conference called to explore the methodology required to develop a behavioral model of system operational readiness (SOR...Participants discussed (4) the behavioral variables that should be included in the model , (2) the system level measures that should be included, (3
Interruption of Neural Function.
1987-05-01
applcbse) University of Colorado I Be. ADDRESS (City. Stele and ZIP Code) 10. SOURCE OF FUNDING NOS. Campus Box B-19 PROGRAM PROJECT TASK WORK UNIT Boulder...rectification, frequency-sensitive phenomena, safety, and some effects on bio - logical systems," invited review, Charles Polk, Ed., CRC Handbook of Biological...experimental test", Mathematical Bio - Sciences, Vol. 29, pp. 235-253, 1978. [131 Kuf1er. S. WV., J. G. Nicholls, and A. R. Martin, "From Nettron to Brain
Potential of pest regulation by insectivorous birds in Mediterranean woody crops.
Rey Benayas, José M; Meltzer, Jorge; de Las Heras-Bravo, Daniel; Cayuela, Luis
2017-01-01
Regulation of agricultural pests managing their natural enemies represents an alternative to chemical pesticides. We assessed the potential of insectivorous birds as pest regulators in woody crops located in central Spain. A total of 417 nest boxes installed in five field study sites (one vineyard, two fruit orchards, and two olive groves) were monitored for use and breeding of insectivorous birds and other species for four consecutive years (2013-2016). At all field sites except the two olive groves, where birds never occupied the nest boxes, predation experiments were conducted with Greater wax moth (Galleria mellonella) sentinel caterpillars, and food consumption by birds was estimated. Nesting of insectivorous birds, chiefly Great tit (Parus major), and sparrows (Passer domesticus and P. montanus) increased over time, averaging 60% per field site in the vineyard and fruit orchards by the fourth year. Use of nest boxes by sparrows and by Garden dormouse (Eliomys quercinus) was high at the fruit orchards (70%) and the vineyard (30%), respectively. Micro-habitat characteristics (nest box level) and meso-habitat characteristics (patch level) strongly affected use of nest boxes and bird breeding (i.e. number of laid eggs and produced chicks) in different years. Distance to natural or semi-natural vegetation did not consistently affect bird breeding, nor did we see consistent evidence of competition between adjacent breeding birds. Predation rates of sentinel caterpillars were approximately one-third higher near boxes with nesting birds (31.51 ± 43.13%) than at paired distant areas without nest boxes (22.45% ± 38.58%). Food consumption by insectivorous birds per ha and breeding season were conservatively estimated to range from 0.02 kg in one fruit orchard to 0.15 kg in the vineyard. We conclude that installation of nest boxes in Mediterranean woody crops enhances populations of insectivorous birds that regulate pests, but that the effects are moderate and highly context-dependent.
Potential of pest regulation by insectivorous birds in Mediterranean woody crops
Meltzer, Jorge; de las Heras-Bravo, Daniel; Cayuela, Luis
2017-01-01
Regulation of agricultural pests managing their natural enemies represents an alternative to chemical pesticides. We assessed the potential of insectivorous birds as pest regulators in woody crops located in central Spain. A total of 417 nest boxes installed in five field study sites (one vineyard, two fruit orchards, and two olive groves) were monitored for use and breeding of insectivorous birds and other species for four consecutive years (2013–2016). At all field sites except the two olive groves, where birds never occupied the nest boxes, predation experiments were conducted with Greater wax moth (Galleria mellonella) sentinel caterpillars, and food consumption by birds was estimated. Nesting of insectivorous birds, chiefly Great tit (Parus major), and sparrows (Passer domesticus and P. montanus) increased over time, averaging 60% per field site in the vineyard and fruit orchards by the fourth year. Use of nest boxes by sparrows and by Garden dormouse (Eliomys quercinus) was high at the fruit orchards (70%) and the vineyard (30%), respectively. Micro-habitat characteristics (nest box level) and meso-habitat characteristics (patch level) strongly affected use of nest boxes and bird breeding (i.e. number of laid eggs and produced chicks) in different years. Distance to natural or semi-natural vegetation did not consistently affect bird breeding, nor did we see consistent evidence of competition between adjacent breeding birds. Predation rates of sentinel caterpillars were approximately one-third higher near boxes with nesting birds (31.51 ± 43.13%) than at paired distant areas without nest boxes (22.45% ± 38.58%). Food consumption by insectivorous birds per ha and breeding season were conservatively estimated to range from 0.02 kg in one fruit orchard to 0.15 kg in the vineyard. We conclude that installation of nest boxes in Mediterranean woody crops enhances populations of insectivorous birds that regulate pests, but that the effects are moderate and highly context-dependent. PMID:28877166
NASA Astrophysics Data System (ADS)
Ballan, Michele; Manzolaro, Mattia; Meneghetti, Giovanni; Andrighetto, Alberto; Monetti, Alberto; Bisoffi, Giovanni; Prete, Gianfranco
2016-06-01
The SPES project at INFN-LNL aims at the production of neutron-rich Radioactive Ion Beams (RIBs) using the ISOL (Isotope Separation On Line) technique. A 40 MeV 200 μA proton beam will directly impinge a uranium carbide target, generating approximately 1013 fissions per second. The target system is installed under vacuum inside a water-cooled chamber, and have to maintain high working temperatures, close to 2000 °C. During operation the proton beam provides the heating power required to keep the target at the desired temperature level. As a consequence, its characteristics have to be strictly controlled in order to avoid undesired overheating. According to the original design of the control system, the proton beam can be suddenly interrupted in case of out of range vacuum or cooling water flow levels. With the aim to improve the reliability of the control system a set of temperature sensors has been installed close to the target. Their types and installation positions were defined taking into consideration the detailed information coming from a dedicated thermal-electric model that allowed to investigate the most critical and inaccessible target hot-spots. This work is focused on the definition and experimental validation of the aforementioned numerical model. Its results were used to appropriately install two type C thermocouples, a PT100 thermo-resistance and a residual primary beam current detector. In addition the numerical model will be used for the definition of appropriate thresholds for each installed temperature sensor, since it allows to define a relationship between the locally measured values with the overall calculated temperature field. In case of over temperatures the monitoring system will send warning signals or in case interrupt the proton beam.
30 CFR 18.53 - High-voltage longwall mining systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...
30 CFR 18.53 - High-voltage longwall mining systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...
30 CFR 18.53 - High-voltage longwall mining systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...
30 CFR 18.53 - High-voltage longwall mining systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...
30 CFR 18.53 - High-voltage longwall mining systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...
30 CFR 75.825 - Power centers.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and be designed and installed as follows: (1) Rated for the maximum phase-to-phase voltage of the circuit; (2) Rated for the full-load current of the circuit that is supplied power through the device. (3... current of the circuit or causes the current to be interrupted automatically before the disconnecting...
Safety and Fire Prevention Guide for Hospital Safety Managers.
1987-04-01
fault circuit interrupter (GFCI) protection is required for each circuit supplying receptacles in hydrotherapy rooms. GFCIs are usually installed in...the hydrotherapy unit instantaneously before a person could receive a fatal shock. [NFPA 70, Sec 680-62(a)] " . 4- 4-I TG No. 152 Apr il 1987 4-6
Economics of a nest-box program for the conservation of an endangered species: a reappraisal
Daniel A. Spring; Michael Bevers; John O.S. Kennedy; Dan Harley
2001-01-01
An optimization model is developed to identify timing and placement strategies for the installation of nest boxes and the harvesting of timber to meet joint timberâwildlife objectives. Optimal management regimes are determined on the basis of their impacts on the local abundance of a threatened species and net present value (NPV) and are identified for a range of NPV...
Field performance of timber bridges. 12, Christian Hollow stress-laminated box-beam bridge
J. P. Wacker; S. C. Catherman; R. G. Winnett
In January 1992, the Christian Hollow bridge was constructed in Steuben County, New York. The bridge is a single-span, stress-laminated box-beam superstructure that is 9.1 m long, 9.8 m wide, and 502 mm deep (30 ft long, 32 ft wide, and 19-3/4 in. deep). The performance of the bridge was continuously monitored for 28 months, beginning shortly after installation....
Influence of forces acting on side of machine on precision machining of large diameter holes
NASA Astrophysics Data System (ADS)
Fedorenko, M. A.; Bondarenko, J. A.; Sanina, T. M.
2018-03-01
One of the most important factors that increase efficiency, durability and reliability of rotating units is precision installation, preventive maintenance work, timely replacing of a failed or worn components and assemblies. These works should be carried out in the operation of the equipment, as the downtime in many cases leads to large financial losses. Stop of one unit of an industrial enterprise can interrupt the technological chain of production, resulting in a possible stop of the entire equipment. Improving the efficiency and optimization of the repair process increases accuracy of installation work when installing equipment, conducting restoration under operating conditions relevant for enterprises of different industries because it eliminates dismantling the equipment, sending it to maintenance, the expectation of equipment return, the new installation with the required quality and accuracy of repair.
How to be Green and Stay in the Black: Environmental Guideline Document.
1997-10-01
of the studies were within the American Society of Heating, Refrigera- tion, and Air conditioning Engineers (ASHRAE) Guidelines. Polaroid plans to...Whitney, Texas Instru- ments-Defense Group, Hughes Missile Systems, Boeing Defense Systems, and General Electric Air - craft Engines . The methodology...boxes, and the need to install space air thermostats. Description For Polaroid’s needs, engineers installed inte- grated, self-contained, thermally
NASA Astrophysics Data System (ADS)
Hirahara, S.; Nakayama, T.; Hori, S.; Sato, T.; Chiba, Y.; Okada, T.; Matsuzawa, T.
2015-12-01
Soon after the 2011 Tohoku earthquake, seismic activity of Tohoku region, NE Japan is induced in the inland area of Akita prefecture and the border area between Fukushima and Yamagata prefectures. We plan to install a total of 80 offline seismic observation stations in these areas for studying the effect of megathrust earthquake on the activities of inland earthquakes. In our project, maintenance will be held twice-a-year for 4 years from 2015 by using 2.0Hz short-period 3-component seismometer, KVS-300 and ultra-low-power data logger, EDR-X7000 (DC12V 0.08W power supply). We installed seismometer on the rock surface or the slope of the natural ground at the possible sites confirmed with low noise level to obtain distinct seismic waveform data. We report an improvement in installation method of the offline seismic observation station in the heavy snowfall area of Tohoku region based on the retrieved data. In the conventional method, seismometer was installed in the hand-dug hole of a slope in case it is not waterproof. Data logger and battery were installed in the box container on the ground surface, and then, GPS antenna was installed on the pole fixed by stepladder. There are risks of the inclination of seismometer and the damage of equipment in heavy snowfall area. In the new method, seismometer is installed in the robust concrete box on the buried basement consists of precast concrete mass to keep its horizontality. Data logger, battery, and GPS antenna are installed on a high place by using a single pole with anchor bolt and a pole mount cabinet to enhance their safety. As a result, total costs of installation are kept down because most of the equipment is reusable. Furthermore, an environmental burden of waste products is reduced.
77 FR 2442 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... removed for any alternative designs (e.g., TDG Aerospace UFI). Japan Airlines (JAL) noted that the... or concurrently with the installation of the ground fault interrupt relays, a dual crossfeed valve is...) Applicability This AD applies to The Boeing Company Model 767-200, -300, - 300F, and -400ER series airplanes...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-18
... installation and maintenance of universal fault interrupters (UFIs) using a certain supplemental type... series airplanes), as an example of an AD issued against the fuel pump motor- impeller assembly to ensure... circuit to burn through the motor-impeller assembly and through the housing. AirTran asserts that an arc...
30 CFR 250.402 - When and how must I secure a well?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations General Requirements § 250.402 When and how must I secure a well? Whenever you interrupt drilling operations, you must install a downhole safety device, such as a cement plug, bridge plug...
A Study of the Effects of Insulation Gaps on Building Heat Loss
1980-04-01
the Guarded Hot Box. Figure 4, taken from ASTM C-236, shows the essential details of the Guarded Hot Box Test Apparatus. Details of the Johns - Manville Research...The walls are 1-3/- inches thick and are of sandwich construction, with a core of 2 pcf polyvinyl-chloride foam ( Johns - Manville Vinylcel) with faces...Council of Canada (NRC) ane at the Johns - Manville Research Center, was installed and tested as a wall. The test history of that pane] is shown in Table 3
NASA Astrophysics Data System (ADS)
Guillotin, N.; Dupont, T.; Gayet, Ph; Pirotte, O.
2017-12-01
The High Intensity and Energy ISOLDE (HIE-ISOLDE) upgrade project at CERN includes the deployment of new superconducting accelerating structures operated at 4.5 K (ultimately of six cryo-modules) installed in series, and the refurbishing of the helium cryo-plant previously used to cool the ALEPH magnet during the operation of the LEP accelerator from 1989 to 2000. The helium refrigerator is connected to a new cryogenic distribution line, supplying a 2000-liter storage dewar and six interconnecting valve boxes (i.e jumper boxes), one for each cryo-module. After a first operation period with one cryo-module during six months in 2015, a second cryo-module has been installed and operated during 2016. The operation of the cryo-plant with these two cryo-modules has required significant technical enhancements and tunings for the compressor station, the cold-box and the cryogenic distribution system in order to reach nominal and stable operational conditions. The present paper describes the commissioning results and the lessons learnt during the operation campaign of 2016 together with the preliminary experience acquired during the 2017 operation phase with a third cryo-module.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Green infrastructure monitoring in Camden, NJ
The Camden County Municipal Utilities Authority (CCMUA) installed green infrastructure Stormwater Control Measures (SCMs) at multiple locations around the city of Camden, NJ. The SCMs include raised downspout planter boxes, rain gardens, and cisterns. The cisterns capture water ...
ERIC Educational Resources Information Center
Manathunga, Catherine; Selkrig, Mark; Baker, Alison
2018-01-01
This article interrogates the construction of a visual and sound installation that juxtaposes contemporary material with historical artefacts regarding academic work to offer an aesthetic mode of interruption in explorations of academic voice in university histories and in the contemporary university. Drawing upon Foucauldian histories of the…
First year results on cistern monitoring in Camden, NJ
The Camden County Municipal Utilities Authority (CCMUA) installed green infrastructure Stormwater Control Measures (SCMs) at multiple locations around the city of Camden, NJ. The SCMs include raised downspout planter boxes, rain gardens, and cisterns. The cisterns capture water ...
Gao, Junhong; Wan, Hong; Kong, Wei; Yue, Hong
2012-01-01
To provide a suitable vehicle-mounted installation to solve the problem of drinking water in the wild. The vehicle-mounted drinking water installation, made up of pre-treatment unit, purification unit, box and VECU, was used to storage, transport and purify water in the wild. The effect of purification was detected by assembling the installation in the wild and observing the change of water turbidity, TDS, the number of total bacteria and coliform bacteria before and after the treatment of water sources. The wild water sources, such as river water, rainwater, well water and spring water could be purified, and the quality of the treated water could meet the requirement of Drinking Water Quality Standard of CJ94-2005. The vehicle-mounted drinking water installation is suitable for purifying water sources in the wild for drinking use.
Mitigation of PID in commercial PV modules using current interruption method
NASA Astrophysics Data System (ADS)
Bora, Birinchi; Oh, Jaewon; Tatapudi, Sai; Sastry, Oruganty S.; Kumar, Rajesh; Prasad, Basudev; Tamizhmani, Govindasamy
2017-08-01
Potential-induced degradation (PID) is known to have a very severe effect on the reliability of PV modules. PID is caused due to the leakage of current from the cell circuit to the grounded frame under humid conditions of high voltage photovoltaic (PV) systems. There are multiple paths for the current leakage. The most dominant leakage path is from the cell to the frame through encapsulant, glass bulk and glass surface. This dominant path can be prevented by interrupting the electrical conductivity at the glass surface. In our previous works related to this topic, we demonstrated the effectiveness of glass surface conductivity interruption technique using one-cell PV coupons. In this work, we demonstrate the effectiveness of this technique using a full size commercial module susceptible to PID. The interruption of surface conductivity of the commercial module was achieved by attaching a narrow, thin flexible glass strips, from Corning, called Willow Glass on the glass surface along the inner edges of the frame. The flexible glass strip was attached to the module glass surface by heating the glass strip with an ionomer adhesive underneath using a handheld heat gun. The PID stress test was performed at 60°C and 85% RH for 96 hours at -600 V. Pre- and post-PID characterizations including I-V and electroluminescence were carried out to determine the performance loss and affected cell areas. This work demonstrates that the PID issue can be effectively addressed by using this current interruption technique. An important benefit of this approach is that this interruption technique can be applied after manufacturing the modules and after installing the modules in the field as well.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 96860. (2) Naval Western Oceanography Center, Pearl Harbor. Contact: Commanding Officer, Naval Western Oceanography Center, Box 113, Pearl Harbor, HI 96860. (3) Naval Air Station, Barbers Point. Contact: Commanding...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 96860. (2) Naval Western Oceanography Center, Pearl Harbor. Contact: Commanding Officer, Naval Western Oceanography Center, Box 113, Pearl Harbor, HI 96860. (3) Naval Air Station, Barbers Point. Contact: Commanding...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 96860. (2) Naval Western Oceanography Center, Pearl Harbor. Contact: Commanding Officer, Naval Western Oceanography Center, Box 113, Pearl Harbor, HI 96860. (3) Naval Air Station, Barbers Point. Contact: Commanding...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 96860. (2) Naval Western Oceanography Center, Pearl Harbor. Contact: Commanding Officer, Naval Western Oceanography Center, Box 113, Pearl Harbor, HI 96860. (3) Naval Air Station, Barbers Point. Contact: Commanding...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 96860. (2) Naval Western Oceanography Center, Pearl Harbor. Contact: Commanding Officer, Naval Western Oceanography Center, Box 113, Pearl Harbor, HI 96860. (3) Naval Air Station, Barbers Point. Contact: Commanding...
First year update on green infrastructure monitoring in Camden, NJ
The Camden County Municipal Utilities Authority (CCMUA) installed green infrastructure Stormwater Control Measures (SCMs) at multiple locations around the city of Camden, NJ. The SCMs include raised downspout planter boxes, rain gardens, and cisterns. The cisterns capture water ...
Cook, Diane J.; Crandall, Aaron S.; Thomas, Brian L.; Krishnan, Narayanan C.
2013-01-01
While the potential benefits of smart home technology are widely recognized, a lightweight design is needed for the benefits to be realized at a large scale. We introduce the CASAS “smart home in a box”, a lightweight smart home design that is easy to install and provides smart home capabilities out of the box with no customization or training. We discuss types of data analysis that have been performed by the CASAS group and can be pursued in the future by using this approach to designing and implementing smart home technologies. PMID:24415794
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-20
... replacement of the power control relays in the P91 and P92 power distribution panels for the fuel boost and override pumps with new, improved relays having a ground fault interrupter (GFI) feature, or installation... specify which relays may be replaced by GFIs or UFIs. We are proposing this AD to prevent pump housing...
Division and Brigade Stationing System: Installation Data Book.
1988-04-01
8217Division and Brigade Stationing Study: An Analysis of Environmental and Socioeconomic Effects (ESC, September 1987); Division and Brigade Stationing Study...composed of 0 partly decomposed moss, leaves , and twigs, matted together with many fine rootlets. In permafrost areas, destruction of this mat...maritime effect is seldom interrupted by drier and cooler continental air. Although rainfall averages about 48 inches a year, Y annual variation is large
Field Trial of an Aerosol-Based Enclosure Sealing Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, Curtis; Springer, David
2015-09-01
This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology.« less
Seithe, Mirko; Morina, Jeronim; Glöckner, Andreas
2016-12-01
The increased interest in complex-interactive behavior on the one hand and the cognitive and affective processes underlying behavior on the other are a challenge for researchers in psychology and behavioral economics. Research often necessitates that participants strategically interact with each other in dyads or groups. At the same time, to investigate the underlying cognitive and affective processes in a fine-grained manner, not only choices but also other variables such as decision time, information search, and pupil dilation should be recorded. The Bonn eXperimental System (BoXS) introduced in this article is an open-source platform that allows interactive as well as non-interactive experiments to be conducted while recording process measures very efficiently and completely browser-based. In the current version, BoXS has particularly been extended to enable conducting interactive eye-tracking and mouse-tracking experiments. One core advantage of BoXS is its simplicity. Using BoXS does not require prior installation for both experimenters and participants, which allows for running studies outside the laboratory and over the internet. Learning to program for BoXS is easy even for researchers without previous programming experience.
NASA Astrophysics Data System (ADS)
Mitsuzawa, K.; Goto, T.; Araki, E.; Watanabe, T.; Sugioka, H.; Kasaya, T.; Sayanagi, K.; Mikada, H.; Fujimoto, H.; Nagao, T.; Koizumi, K.; Asakawa, K.
2005-12-01
Western part of the Sagami Bay central Pacific side of Japan, is known as one of the high active tectonic areas. In this area, Teishi Knoll, volcanic seamount, erupted in 1989 and the earthquake swarms occurs repeatedly every few years in the eastern coast of the Izu Peninsula. The real-time deep sea floor observatory was deployed about 7 km off Hatsushima Island, Sagami Bay, at a depth of 1174 m in 1993 to monitor seismic activities, underwater pressure, water temperature and deep currents. The video camera and lights were also mounted in the observatory to monitor the relations among biological activities associated with the tectonic activities. The observation system including submarine electro-optical cable with a length of 8 km was completely renewed in 2000. The several underwater-mateable connectors are installed in the new observatory for additional observation instruments. A precise pressure sensor, ocean bottom gravity meter and ocean bottom electro-magnetic meter were installed using ROV Hyper-Dolphin in the cruise of R/V Natsushima from January 9 to 14, 2005. We start to operate them at February 10, 2005 after checking those of data qualities. We also installed an underwater internet interface, which is called Linux Box, as a prototype of underwater network system which was operated by Linux operating system. The Linux Box is a key network system for multidisciplinary observation network. It will be able to connect much kind of observation instruments as using internet connection. We put the precise pressure sensor as a sensor of the Linux Box in this experiment.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Radio Astronomy and Radio Research Installations. In order to minimize harmful interference at the National Radio Astronomy Observatory site located at Green Bank, Pocahontas County, W. Va., and at the... Astronomy Observatory, Post Office Box No. 2, Green Bank, WV 24944, in writing, of the technical particulars...
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Radio Astronomy and Radio Research Installations. In order to minimize harmful interference at the National Radio Astronomy Observatory site located at Green Bank, Pocahontas County, W. Va., and at the... Astronomy Observatory, Post Office Box No. 2, Green Bank, WV 24944, in writing, of the technical particulars...
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Radio Astronomy and Radio Research Installations. In order to minimize harmful interference at the National Radio Astronomy Observatory site located at Green Bank, Pocahontas County, W. Va., and at the... Astronomy Observatory, Post Office Box No. 2, Green Bank, WV 24944, in writing, of the technical particulars...
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Radio Astronomy and Radio Research Installations. In order to minimize harmful interference at the National Radio Astronomy Observatory site located at Green Bank, Pocahontas County, W. Va., and at the... Astronomy Observatory, Post Office Box No. 2, Green Bank, WV 24944, in writing, of the technical particulars...
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Radio Astronomy and Radio Research Installations. In order to minimize harmful interference at the National Radio Astronomy Observatory site located at Green Bank, Pocahontas County, W. Va., and at the... Astronomy Observatory, Post Office Box No. 2, Green Bank, WV 24944, in writing, of the technical particulars...
46 CFR 111.15-10 - Ventilation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-10 Ventilation. (a) General. Each room, locker, and box for storage batteries must be arranged or ventilated to prevent... with the battery charger so that the battery cannot be charged without ventilation. (c) Large battery...
46 CFR 111.15-10 - Ventilation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-10 Ventilation. (a) General. Each room, locker, and box for storage batteries must be arranged or ventilated to prevent... with the battery charger so that the battery cannot be charged without ventilation. (c) Large battery...
46 CFR 111.15-10 - Ventilation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-10 Ventilation. (a) General. Each room, locker, and box for storage batteries must be arranged or ventilated to prevent... with the battery charger so that the battery cannot be charged without ventilation. (c) Large battery...
46 CFR 111.15-10 - Ventilation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-10 Ventilation. (a) General. Each room, locker, and box for storage batteries must be arranged or ventilated to prevent... with the battery charger so that the battery cannot be charged without ventilation. (c) Large battery...
46 CFR 111.15-10 - Ventilation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-10 Ventilation. (a) General. Each room, locker, and box for storage batteries must be arranged or ventilated to prevent... with the battery charger so that the battery cannot be charged without ventilation. (c) Large battery...
2003-08-27
KENNEDY SPACE CENTER, FLA. - During power-up of the orbiter Discovery in the Orbiter Processing Facility, a technician moves a switch. Discovery has been undergoing Orbiter Major Modifications in the past year, ranging from wiring, control panels and black boxes to gaseous and fluid systems tubing and components. These systems were deserviced, disassembled, inspected, modified, reassembled, checked out and reserviced, as were most other systems onboard. The work includes the installation of the Multifunction Electronic Display Subsystem (MEDS) - a state-of-the-art “glass cockpit.”
2003-08-27
KENNEDY SPACE CENTER, FLA. - During power-up of the orbiter Discovery in the Orbiter Processing Facility, a technician turns on a switch. Discovery has been undergoing Orbiter Major Modifications in the past year, ranging from wiring, control panels and black boxes to gaseous and fluid systems tubing and components. These systems were deserviced, disassembled, inspected, modified, reassembled, checked out and reserviced, as were most other systems onboard. The work includes the installation of the Multifunction Electronic Display Subsystem (MEDS) - a state-of-the-art “glass cockpit.”
Code of Federal Regulations, 2013 CFR
2013-10-01
... cable connecting the shore power connection box or receptacle to the switchboard or main distribution... 46 Shipping 4 2013-10-01 2013-10-01 false Shore power. 120.390 Section 120.390 Shipping COAST... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS ELECTRICAL INSTALLATION Power Sources...
Chen, Yu-Xian
2018-01-01
This study designed a radio-frequency identification (RFID)-based Internet of Things (IoT) platform to create the core of a smart nest box. At the sensing level, we have deployed RFID-based sensors and egg detection sensors. A low-frequency RFID reader is installed in the bottom of the nest box and a foot ring RFID tag is worn on the leg of individual hens. The RFID-based sensors detect when a hen enters or exits the nest box. The egg-detection sensors are implemented with a resistance strain gauge pressure sensor, which weights the egg in the egg-collection tube. Thus, the smart nest box makes it possible to analyze the laying performance and behavior of individual hens. An evaluative experiment was performed using an enriched cage, a smart nest box, web camera, and monitoring console. The hens were allowed 14 days to become accustomed to the experimental environment before monitoring began. The proposed IoT platform makes it possible to analyze the egg yield of individual hens in real time, thereby enabling the replacement of hens with egg yield below a pre-defined level in order to meet the overall target egg yield rate. The results of this experiment demonstrate the efficacy of the proposed RFID-based smart nest box in monitoring the egg yield and laying behavior of individual hens. PMID:29538334
Chien, Ying-Ren; Chen, Yu-Xian
2018-03-14
This study designed a radio-frequency identification (RFID)-based Internet of Things (IoT) platform to create the core of a smart nest box. At the sensing level, we have deployed RFID-based sensors and egg detection sensors. A low-frequency RFID reader is installed in the bottom of the nest box and a foot ring RFID tag is worn on the leg of individual hens. The RFID-based sensors detect when a hen enters or exits the nest box. The egg-detection sensors are implemented with a resistance strain gauge pressure sensor, which weights the egg in the egg-collection tube. Thus, the smart nest box makes it possible to analyze the laying performance and behavior of individual hens. An evaluative experiment was performed using an enriched cage, a smart nest box, web camera, and monitoring console. The hens were allowed 14 days to become accustomed to the experimental environment before monitoring began. The proposed IoT platform makes it possible to analyze the egg yield of individual hens in real time, thereby enabling the replacement of hens with egg yield below a pre-defined level in order to meet the overall target egg yield rate. The results of this experiment demonstrate the efficacy of the proposed RFID-based smart nest box in monitoring the egg yield and laying behavior of individual hens.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Godwin, Aaron
The scope will be limited to analyzing the effect of the EFC within the system and how one improperly installed coupling affects the rest of the HPFL system. The discussion will include normal operations, impaired flow, and service interruptions. Normal operations are defined as two-way flow to buildings. Impaired operations are defined as a building that only has one-way flow being provided to the building. Service interruptions will be when a building does not have water available to it. The project will look at the following aspects of the reliability of the HPFL system: mean time to failure (MTTF) ofmore » EFCs, mean time between failures (MTBF), series system models, and parallel system models. These calculations will then be used to discuss the reliability of the system when one of the couplings fails. Compare the reliability of two-way feeds versus one-way feeds.« less
Action Cam Footage from U.S. Spacewalk 41
2017-05-09
This footage was taken by NASA astronaut Peggy Whitson during a spacewalk on the International Space Station on Thursday, March 30. She was joined on the spacewalk by NASA astronaut Shane Kimbrough. The two spacewalkers reconnected cables and electrical connections on PMA-3 at its new home on top of the Harmony module. They also installed the second of the two upgraded computer relay boxes on the station’s truss and installed shields and covers on PMA-3 and the now-vacant common berthing mechanism port on Tranquility.
Stokke, Jennifer M; Mazyck, David W
2008-04-01
The release of mercury to the environment is of particular concern because of its volatility, persistence, and tendency to bioaccumulate. The recovery of mercury from end-box exhaust at chlor-alkali facilities is important to prevent release into the environment and reduce emissions as required by NESHAP (National Emission Standards for Hazardous Air Pollutants). A pilot-scale photocatalytic reactor packed with silica-titania composite (STC) pellets was tested at a chloralkali facility over a 3-month period. This pilot reactor treated up to 10 ft3/min (ACFM) of end-box exhaust and achieved 95% removal. The pilot reactor was able to maintain excellent removal efficiency even with large fluctuations in influent mercury concentration (400-1600 microg/ft3). The STC pellets were regenerated ex situ by regeneration with hydrochloric acid and performed similarly to virgin STC pellets when returned to service. On the basis of these promising results, two full-scale reactors with in situ regeneration capabilities were installed and operated. After optimization, these reactors performed similarly to the pilot reactor. A cost analysis was performed comparing the treatment costs (i.e., cost per pound of mercury removed) for sulfur-impregnated activated carbon and the STC system. The STC proved to be both technologically and economically feasible for this installation.
Wang, Guohao; Xu, Yuquan
2012-01-01
Pseudomonas aeruginosa M18, a rhizosphere-isolated bacterial strain showing strong antifungal activity, can produce secondary metabolites such as phenazine-1-carboxylic acid and pyoluteorin (Plt). The LysR-type transcriptional regulator PltR activates the Plt biosynthesis operon pltLABCDEFG, the expression of which is induced by Plt. Here, we identified and characterized the non-conserved pltL promoter (pltLp) specifically activated by PltR and its upstream neighboring lys box from the complicated pltR–pltL intergenic sequence. The 22 bp palindromic lys box, which consists of two 9 bp complementary inverted repeats interrupted by 4 bp, was found to contain the conserved, GC-rich LysR-binding motif (T-N11-A). Evidence obtained in vivo from mutational and lacZ report analyses and in vitro from electrophoretic mobility shift assays reveals that the PltR protein directly bound to the pltLp region as the indispensable binding motif “lys box”, thereby transcriptionally activating the pltLp-driven plt operon expression. Plt, as a potential non-essential coinducer of PltR, specifically induced the pltLp expression and thus strengthened its biosynthetic plt operon expression. PMID:22761817
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-14
..., Notifications Concerning Interference to Radio Astronomy, Research and Receiving Installations. Form Number: N/A... Astronomy Observatory site located at Green, Pocahontas County, West Virginia, and at the Naval Radio... the west, shall notify the Interference Office, National Radio Astronomy Observatory, P.O. Box 2...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-22
..., Notifications Concerning Interference to Radio Astronomy, Research and Receiving Installations. Form Number: N/A... Astronomy Observatory site located at Green, Pocahontas County, West Virginia, and at the Naval Radio... Interference Office, National Radio Astronomy Observatory, P.O. Box 2, Green Bank, West Virginia 24944...
Evaluation of the Navy Master Planning Program
1976-05-01
34The most clear-cut evidence of the primitive state of federal self -evaluation lies in the widespread failure of agencies even to spell out program...the appropriate boxes and weight the respose , ŕ" to ř", depending on relative impact of the item selected). 1) change in installation mission
40 CFR 62.14104 - Requirements for municipal waste combustor operating practices.
Code of Federal Regulations, 2013 CFR
2013-07-01
...), proceed in accordance with ASME PTC 4.1-1964 (Reaffirmed 1991), Power Test Codes: Test Code for Steam Generating Units (with 1968 and 1969 Addenda). For design, construction, installation, calibration, and use... Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You may...
40 CFR 62.14104 - Requirements for municipal waste combustor operating practices.
Code of Federal Regulations, 2014 CFR
2014-07-01
...), proceed in accordance with ASME PTC 4.1-1964 (Reaffirmed 1991), Power Test Codes: Test Code for Steam Generating Units (with 1968 and 1969 Addenda). For design, construction, installation, calibration, and use... Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You may...
40 CFR 62.14104 - Requirements for municipal waste combustor operating practices.
Code of Federal Regulations, 2010 CFR
2010-07-01
...), proceed in accordance with ASME PTC 4.1-1964 (Reaffirmed 1991), Power Test Codes: Test Code for Steam Generating Units (with 1968 and 1969 Addenda). For design, construction, installation, calibration, and use... Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You may...
40 CFR 62.14104 - Requirements for municipal waste combustor operating practices.
Code of Federal Regulations, 2012 CFR
2012-07-01
...), proceed in accordance with ASME PTC 4.1-1964 (Reaffirmed 1991), Power Test Codes: Test Code for Steam Generating Units (with 1968 and 1969 Addenda). For design, construction, installation, calibration, and use... Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You may...
40 CFR 62.14104 - Requirements for municipal waste combustor operating practices.
Code of Federal Regulations, 2011 CFR
2011-07-01
...), proceed in accordance with ASME PTC 4.1-1964 (Reaffirmed 1991), Power Test Codes: Test Code for Steam Generating Units (with 1968 and 1969 Addenda). For design, construction, installation, calibration, and use... Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You may...
46 CFR 185.612 - Fire protection equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... releasing the extinguishing agent should the local manual release or stop valve controls fail to operate... at or near each pull box and stop valve control and in the space where the extinguishing agent...-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED”. Where a different extinguishing agent is installed, that...
Code of Federal Regulations, 2014 CFR
2014-10-01
... at a convenient location; (b) A cable connecting the shore power connection box or receptacle to the... 46 Shipping 7 2014-10-01 2014-10-01 false Shore power. 183.390 Section 183.390 Shipping COAST...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.390 Shore power. A vessel with an...
Code of Federal Regulations, 2012 CFR
2012-10-01
... at a convenient location; (b) A cable connecting the shore power connection box or receptacle to the... 46 Shipping 7 2012-10-01 2012-10-01 false Shore power. 183.390 Section 183.390 Shipping COAST...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.390 Shore power. A vessel with an...
78 FR 6200 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-30
... by installing a placard with the new (reduced) maximum load. We disagree because the customer COS box.... ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for certain The Boeing... under forward load levels less than the 9 g forward load requirements as defined by certain regulations...
Ty Lepionka Uses Disposal System Model to Communicate With Public
ERIC Educational Resources Information Center
Vassey, Emuel E., III
1976-01-01
A sanitarian uses a model to demonstrate installation and operation of a subsurface disposal system. The model contains a septic tank, inlet and outlet T's, distribution box, and drain lines in various stages of construction. The model is used to inform mobile home owners about environmental health practices. (MR)
78 FR 18531 - Airworthiness Directives; Learjet Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... cause damage to various components, including the MLG squat switches, brake hydraulic tubes, wheel speed... airplanes. This proposed AD was prompted by a report of a high-speed rejected takeoff caused by all four... necessary; and, for certain airplanes; installing a new wheel speed detect box assembly, nutplates, and...
Depending on Data: Business Intelligence Systems Drive Reform
ERIC Educational Resources Information Center
Halligan, Tom
2010-01-01
As more community colleges focus on using data to improve educational outcomes, many administrators are considering business intelligence applications that promise a path toward more informed decisions. Getting there, leaders say, requires more than installing some out-of-the-box solution; it requires changing the culture and finding skilled…
Alternative Financing of Alternative Energy.
ERIC Educational Resources Information Center
California Higher Education, 1982
1982-01-01
The University of San Francisco financed conversion of three dormitories to solar heat by having private investors purchase and install equipment through a limited partnership. A public utilities rebate and eventual donation of the equipment also resulted. Available from California Higher Education, P.O. Box 26541, Sacramento, CA 95826, $2.00.…
The Cheapbook: A Compendium of Inexpensive Exhibit Ideas, 1995 Edition.
ERIC Educational Resources Information Center
Orselli, Paul, Ed.
This guide includes complete installation descriptions of 30 exhibits. They include: the adjustable birthday cake, ball-in-tube, Bernoulli Box, chain wave, collapsible truss bridge, double wave device, eddy currents raceway, full-length mirror, geodesic domes, giant magnetic tangrams, harmonic cantilever, hyperboloid of revolution, lifting lever,…
76 FR 12617 - Airworthiness Directives; The Boeing Company Model 777-200 and -300 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... installing new operational software for the electrical load management system and configuration database... the electrical load management system operational software and configuration database software, in... Management, P.O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; telephone 206- 544-5000, extension 1...
Ma, Tracey; Byrne, Patrick A; Bhatti, Junaid A; Elzohairy, Yoassry
2016-10-01
Drinking and driving is a major risk factor for traffic injuries. Although ignition interlocks reduce drinking and driving while installed, several issues undermine their implementation including delayed eligibility for installation, low installation once eligible, and a return to previous risk levels after de-installation. The Canadian province of Ontario introduced a "Reduced Suspension with Ignition Interlock Conduct Review" Program, significantly changing pre-existing interlock policy. The Program incentivizes interlock installation and an "early" guilty plea. It also attempts to reduce long-term recidivism through behavioural feedback and compliance-based removal. This evaluation is the first in assessing Program impact. Ontario drivers with a first time alcohol-impaired driving conviction between July 1, 2005 and November 25, 2014 comprised the study cohort. Longitudinal analyses, using interrupted time series and Cox regression, were conducted in which exposure was the Program and the outcomes were ignition interlock installation (N=30,200), pre-trial elapsed time (N=30,200), and post-interlock recidivism (N=9326). After Program implementation, installation rates increased by 54% and pre-trial elapsed time decreased by 146 days. Results suggest no effect on post-interlock recidivism. Through an incentive-based design, this Program was effective at addressing two commonly cited barriers to interlock implementation- delayed eligibility for installation and low installation once eligible. Results reveal that installation rates are responsive not only to incentivization but also to other external factors, thus presenting an opportunity for policy makers to find unique ways to influence interlock uptake, and thereby, to extend their deterrent effects to a larger subset of the population. This study is one of the few that do not rely on proxy measures of installation rate. Copyright © 2016 Crown. Published by Elsevier Ltd.. All rights reserved.
Loop Group Parakeet Virtual Cable Concept Demonstrator
NASA Astrophysics Data System (ADS)
Dowsett, T.; McNeill, T. C.; Reynolds, A. B.; Blair, W. D.
2002-07-01
The Parakeet Virtual Cable (PVC) concept demonstrator uses the Ethernet Local Area Network (LAN) laid for the Battle Command Support System (BCSS) to connect the Parakeet DVT(DA) (voice terminal) to the Parakeet multiplexer. This currently requires pairs of PVC interface units to be installed for each DVT(DA) . To reduce the cost of a PVC installation, the concept of a Loop Group Parakeet Virtual Cable (LGPVC) was proposed. This device was designed to replace the up to 30 PVC boxes and the multiplexer at the multiplexer side of a PVC installation. While the demonstrator is largely complete, testing has revealed an incomplete understanding of how to emulate the proprietary handshaking occurring between the circuit switch and the multiplexer. The LGPVC concept cannot yet be demonstrated.
Biased insert for installing data transmission components in downhole drilling pipe
Hall, David R [Provo, UT; Briscoe, Michael A [Lehi, UT; Garner, Kory K [Payson, UT; Wilde, Tyson J [Spanish Fork, UT
2007-04-10
An apparatus for installing data transmission hardware in downhole tools includes an insert insertable into the box end or pin end of drill tool, such as a section of drill pipe. The insert typically includes a mount portion and a slide portion. A data transmission element is mounted in the slide portion of the insert. A biasing element is installed between the mount portion and the slide portion and is configured to create a bias between the slide portion and the mount portion. This biasing element is configured to compensate for varying tolerances encountered in different types of downhole tools. In selected embodiments, the biasing element is an elastomeric material, a spring, compressed gas, or a combination thereof.
Christophersen, Jon; Morrison, Bill
2018-02-14
Energy storage devices, primarily batteries, are now more important to consumers, industries and the military. With increasing technical complexity and higher user expectations, there is also a demand for highly accurate state-of-health battery assessment techniques. IMB incorporates patented, proprietary, and tested capabilities using control software and hardware that can be part of an embedded monitoring system. IMB directly measures the wideband impedance spectrum in seconds during battery operation with no significant impact on service life. It also can be applied to batteries prior to installation, confirming health before entering active service, as well as during regular maintenance. For more information about this project, visit http://www.inl.gov/rd100/2011/impedance-measurement-box/
Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganni, Venkatarao; Knudsen, Peter N.; Arenius, Dana M.
The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system.
Dismantling of the PETRA glove box: tritium contamination and inventory assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, R.
2015-03-15
The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followedmore » by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)« less
Opto-box: Optical modules and mini-crate for ATLAS pixel and IBL detectors
NASA Astrophysics Data System (ADS)
Bertsche, David
2016-11-01
The opto-box is a custom mini-crate for housing optical modules which process and transfer optoelectronic data. Many novel solutions were developed for the custom design and manufacturing. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35×10x8 cm3. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits, were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain. This conference proceeding is in support of the poster presented at the International Conference on New Frontiers in Physics (ICNFP) 2015 [1].
32 CFR 552.103 - Requirements for carrying and use.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and return. Stopping at other installation facilities while enroute is prohibited (i.e., Post Exchange..., weapons will be carried in an open manner (not concealed). Firearms will be unloaded when carried (i.e... readily accessible from the passenger area (i.e., locked tool box secured to bed of a truck). Firearms...
Pyrolysis oil combustion in a horizontal box furnace with an externally mixed nozzle
USDA-ARS?s Scientific Manuscript database
Combustion characteristics of neat biomass fast-pyrolysis oil were studied in a horizontal combustion chamber with a rectangular cross-section. An air-assisted externally mixed nozzle known to successfully atomize heavy fuel oils was installed in a modified nominal 100 kW (350,000 BTU/h nominal cap...
75 FR 15328 - Airworthiness Directives; The Boeing Company Model 757 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
... the flightcrew and supernumerary oxygen system installed under the oxygen mask stowage box at a flightcrew and supernumerary oxygen mask location, and replacing with a new non-conductive low-pressure flex-hose of the oxygen system if necessary. This AD results from reports of a low-pressure flex-hose of a...
46 CFR 110.10-1 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; 111.105-40; 113.05-7; and (2) Rules for Building and Classing Mobile Offshore Drilling Units, Part 4...-1; (31) IEC 61363-1 Electrical Installations of Ships and Mobile and Fixed Offshore Units—Part 1.... Box 12277, Research Triangle Park, NC 27709: (1) RP 12.6, Wiring Practices for Hazardous (Classified...
Connect Them Bones! An Interdisciplinary Study of Owl Pellets.
ERIC Educational Resources Information Center
Zipko, Stephen J.
1983-01-01
Discusses a field/laboratory study of the barn owl in which students collect and dissect owl pellets. Interdisciplinary lessons focus on eco-politics, reconstruction of owl prey skeletons, studies of predator-prey relationships, and construction/installation of nest boxes for owls and other birds. The unit begins and ends with an attitude…
ERIC Educational Resources Information Center
Collett, Peter
Data were collected for this study of the relationship between television watching and family life via a recording device (C-Box) consisting of a television set and a video camera. Designed for the study, this device was installed in 20 homes for one week to record the viewing area in front of the television set together with information on…
78 FR 51816 - Notice of Actions on Special Permit Applications
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-21
... OtterBox, Fort transportation in commerce Collins, CO. of a lithium ion battery which is permanently installed in a cell phone case as ``Lithium batteries contained in equipment.'' (modes 1, 4, 5) Denied 11296.... transportation in commerce of certain damaged or defective lithium batteries. (modes 1, 2, 3) Emergency Special...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
... assemblies (crosstubes) installed on Agusta S.p.A. (Agusta) Model AB412 and AB412EP; and Bell Helicopter... based on a supplemental type certificate (STC). This AD requires counting and recording the total number.... ADDRESSES: For service information identified in this AD, contact Aeronautical Accessories, Inc., P.O. Box...
Identification and modeling of the electrohydraulic systems of the main gun of a main battle tank
NASA Astrophysics Data System (ADS)
Campos, Luiz C. A.; Menegaldo, Luciano L.
2012-11-01
The black-box mathematical models of the electrohydraulic systems responsible for driving the two degrees of freedom (elevation and azimuth) of the main gun of a main battle tank (MBT) were identified. Such systems respond to gunner's inputs while acquiring and tracking targets. Identification experiments were designed to collect simultaneous data from two inertial measurement units (IMU) installed at the gunner's handle (input) and at the center of rotation of the turret (output), for the identification of the azimuth system. For the elevation system, IMUs were installed at the gunner's handle (input) and at the breech of the gun (output). Linear accelerations and angular rates were collected for both input and output. Several black-box model architectures were investigated. As a result, nonlinear autoregressive with exogenous variables (NARX) second order model and nonlinear finite impulse response (NFIR) fourth order model, demonstrate to best fit the experimental data, with low computational costs. The derived models are being employed in a broader research, aiming to reproduce such systems in a laboratory virtual main gun simulator.
2003-08-27
KENNEDY SPACE CENTER, FLA. - During power-up of the orbiter Discovery in the Orbiter Processing Facility, a technician (left) looks at the circuit breaker lights in the cabin. Discovery has been undergoing Orbiter Major Modifications in the past year, ranging from wiring, control panels and black boxes to gaseous and fluid systems tubing and components. These systems were deserviced, disassembled, inspected, modified, reassembled, checked out and reserviced, as were most other systems onboard. The work includes the installation of the Multifunction Electronic Display Subsystem (MEDS) - a state-of-the-art “glass cockpit.”
Remediating Third-Party Software Vulnerabilities on U.S. Army Information Systems
2012-06-01
tended to result in the defacement of websites. Attacks coming from Eastern Europe and Russia were directed primarily at Point of Sale (PoS) systems.55...interrupt the user to ask their permission to install a security update. This method is used by Sun Java, Apple QuickTime/Safari/ iTunes , Adobe Flash...only be obtained by contacting its sales department. Several vendors offered a wide range of useful videos, including Microsoft, LANDesk, CFEngine
Cooling system for electronic components
Anderl, William James; Colgan, Evan George; Gerken, James Dorance; Marroquin, Christopher Michael; Tian, Shurong
2015-12-15
Embodiments of the present invention provide for non interruptive fluid cooling of an electronic enclosure. One or more electronic component packages may be removable from a circuit card having a fluid flow system. When installed, the electronic component packages are coincident to and in a thermal relationship with the fluid flow system. If a particular electronic component package becomes non-functional, it may be removed from the electronic enclosure without affecting either the fluid flow system or other neighboring electronic component packages.
Cooling system for electronic components
Anderl, William James; Colgan, Evan George; Gerken, James Dorance; Marroquin, Christopher Michael; Tian, Shurong
2016-05-17
Embodiments of the present invention provide for non interruptive fluid cooling of an electronic enclosure. One or more electronic component packages may be removable from a circuit card having a fluid flow system. When installed, the electronic component packages are coincident to and in a thermal relationship with the fluid flow system. If a particular electronic component package becomes non-functional, it may be removed from the electronic enclosure without affecting either the fluid flow system or other neighboring electronic component packages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malcolm, J; Mein, S; McNiven, A
2015-06-15
Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria ofmore » 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.« less
Solar hot water system installed at Day's Lodge, Atlanta, Georgia
NASA Technical Reports Server (NTRS)
1980-01-01
The solar energy hot water system installed in the Days Inns of America, Inc., Atlanta, Georgia is described. This system provides for 81 percent of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drain whenever the collector plates approach freezing or when power is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric Domestic Hot Water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting.
Solar hot water system installed at Quality Inn, Key West, Florida
NASA Astrophysics Data System (ADS)
1980-04-01
The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.
Solar hot water system installed at Quality Inn, Key West, Florida
NASA Technical Reports Server (NTRS)
1980-01-01
The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.
Wagner, Stephen J; Myrup, Andrew; Awatefe, Helen; Thompson-Montgomery, Dedeene; Hirayama, Junichi; Skripchenko, Andrey
2008-12-01
Extensive periods without agitation can occasionally occur during platelet (PLT) shipment and can affect PLT quality during 5- to 7-day storage. The use of buffer-containing PLT additive solutions (ASs) may better preserve PLT quality during storage by maintaining PLT pH and other in vitro variables. A newly described bicarbonate-containing AS, M-sol, was compared to plasma for preservation of whole blood-derived PLT concentrates in which a 30-hour interruption of agitation was included. ABO-identical PLT-rich plasma intermediate products were pooled in sets of four, split, and centrifuged with subsequent plasma expression (n = 12). Two units were resuspended with M-sol AS to produce a 70 percent solution/30 percent plasma PLT concentrate; 2 units were resuspended in 100 percent plasma. One M-sol resuspended unit and 1 plasma unit were held on a laboratory bench in a standard shipping box for 30 hours between Day 2 and Day 3, while the other M-sol and plasma unit were continuously agitated. Standard in vitro testing for PLT quality variables on each set of 4 units was performed during storage (n = 12). Interrupting agitation of PLTs suspended in M-sol resulted in less of a pH decrement during storage than that of PLTs suspended in 100 percent plasma. On Days 5 and 7, the pH differences between M-sol and plasma units were 0.56 and 0.75 pH units, respectively (p < 0.0003). In addition, PLTs suspended in M-sol and subjected to an interruption of agitation had lesser Day 7 CD62+ cells, glucose utilization, and lactate production and greater hypotonic stress response, morphology, swirling, and aggregation response than those suspended in plasma (p = 0.005). The in vitro properties of PLTs suspended in 70 percent M-sol/30 percent plasma and subjected to a 30-hour interruption of agitation are better maintained during 7-day storage than those of matched units suspended in plasma.
Injuries in competitive boxing. A prospective study.
Siewe, J; Rudat, J; Zarghooni, K; Sobottke, R; Eysel, P; Herren, C; Knöll, P; Illgner, U; Michael, J
2015-03-01
Boxing remains a subject of controversy and is often classified as dangerous. But the discussion is based mostly on retrospective studies. This survey was conducted as a prospective study. From October 2012 to September 2013, 44 competitive boxers were asked to report their injuries once a month. The questionnaire collected general information (training, competition) and recorded the number of bouts fought, injuries and resulting lost days. A total of 192 injuries were recorded, 133 of which resulted in interruption of training or competition. Each boxer sustained 3 injuries per year on average. The injury rate was 12.8 injuries per 1 000 h of training. Boxers fighting more than 3 bouts per year sustain more injuries (p=0.0075). The injury rate does is not a function of age (age≤19 vs. > 19a, p=0.53). Injuries to the head and the upper limbs occur most frequently. The most common injuries are soft tissue lacerations and contusions. Head injuries with neurological symptoms rarely occur (4.2%). Boxing has a high injury rate that is comparable with other contact sports, but most injuries are minor. Injury frequency is not a function of whether the boxer competes in the junior or adult category. Athletes fighting many bouts per year have a greater risk of injury. © Georg Thieme Verlag KG Stuttgart · New York.
Quantitative understanding of explosive stimulus transfer
NASA Technical Reports Server (NTRS)
Schimmel, M. L.
1973-01-01
The mechanisms of detonation transfer across hermetically sealed interfaces created by necessary interruptions in high explosive trains, such as at detonators to explosive columns, field joints in explosive columns, and components of munitions fuse trains are demostrated. Reliability of detonation transfer is limited by minimizing explosive quantities, the use of intensitive explosives for safety, and requirements to propagate across gaps and angles dictated by installation and production restraints. The major detonation transfer variables studied were: explosive quanity, sensitivity, and thickness, and the separation distances between donor and acceptor explosives.
NASA Astrophysics Data System (ADS)
Yokomizu, Yasunobu
Dispersed generation systems, such as micro gas-turbines and fuel cells, have been installed on some of commercial facilities. Smaller dispersed generators like solar photovoltaics have been also located on the several of individual homes. The trends in the introduction of the these generation systems seem to continue in the future and to cause the power system to have the enormous number of the dispersed generation systems. The present report discusses the near-future power distribution systems.
Data Center Energy Efficiency Measurement Assessment Kit Guide and Specification
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-10-26
A portable and temporary wireless mesh assessment kit can be used to speed up and reduce the costs of a data center energy use assessment and overcome the issues with respect to shutdowns. The assessment kit is comprised of temperature, relative humidity, and pressure sensors. Also included are power meters that can be installed on computer room air conditioners (CRACs) without intrusive interruption of data center operations. The assessment kit produces data required for a detailed energy assessment of the data center.
Operation and maintenance cost data for residential photovoltaic modules/panels
NASA Technical Reports Server (NTRS)
Oster, J. R., Jr.; Zaremski, D. R., Jr.; Albert, E. M.; Hawkins, S. L.
1980-01-01
Costs associated with the operation and maintenance of residential photovoltaic modules and arrays are studied. Six basic topics related to operation and maintenance to photovoltaic arrays are investigated: maintenance; cleaning; panel replacement; gasket repair/replacement; wiring repair/replacement; and termination repair/replacement. The effects of the mounting types (rack mount, stand off mount, direct mount and integral mount) and the installation/replacement type (sequential, partial interruption and independent) are identified and described. Methods of reducing maintenance costs are suggested.
1988-06-01
Mencer Mitzi S. Miller Dist J. W. Zolyniak Prepared by the Oak Ridge Gaseous Diffusion Plant Oak Ridge, Tennessee 37831 operated by MARTIN MARIETTA...Drop A20 S Oak Ridge, TN 37830 * Mailing Address for Regular Mail: Martin Marietta Energy Systems, Inc. P.O. Box 2003 Oak Ridge, TN 37831-7440 Mitzi
Code of Federal Regulations, 2011 CFR
2011-07-01
... NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 Edition 126.15 NFPA 14, Standard for...-2959: ASTM F-1121, Standard Specification for International Shore Connections for Marine Fire Applications, 1987 Edition 126.15 National Fire Protection Association (NFPA), One Batterymarch Park, P.O. Box...
Code of Federal Regulations, 2012 CFR
2012-07-01
... NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 Edition 126.15 NFPA 14, Standard for...-2959: ASTM F-1121, Standard Specification for International Shore Connections for Marine Fire Applications, 1987 Edition 126.15 National Fire Protection Association (NFPA), One Batterymarch Park, P.O. Box...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... verify the part number of the low-pressure flex-hoses of the flightcrew and supernumerary oxygen system installed under the oxygen mask stowage box at flightcrew and supernumerary oxygen mask locations, and... reports of low- pressure flex-hoses of the flightcrew oxygen system that burned through due to inadvertent...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... AD requires inspecting to verify the part number of the low-pressure flex-hoses of the crew oxygen system installed under the oxygen mask stowage boxes located within the flight deck, and replacing the... of low-pressure flex-hoses of the crew oxygen system that burned through due to inadvertent...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
... oxygen system installed under the oxygen mask stowage box at a flightcrew and supernumerary oxygen mask... proposed AD results from reports of a low-pressure flex-hose of the flightcrew oxygen system that burned...-hoses used in the flightcrew and supernumerary oxygen systems to melt or burn, resulting in oxygen...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
... oxygen system installed under the oxygen mask stowage boxes located within the flight deck, and replacing... from reports of low-pressure flex-hoses of the crew oxygen system that burned through due to... prevent inadvertent electrical current, which can cause the low-pressure flex-hoses of the crew oxygen...
Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Rough-In.
ERIC Educational Resources Information Center
Arneson, R.; And Others
One of two individualized courses included in an electrical wiring curriculum, this course covers electrical installations that are generally hidden within the structure. The course is comprised of four units: (1) Outlet and Switch Boxes, (2) Wiring, (3) Service Entrance, and (4) Signal and Low Voltage Systems. Each unit begins with a Unit…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-26
... prevention and waste management data, including recycling information, for such chemicals. 42 U.S.C. 13106..., install, and utilize technology and systems for the purposes of collecting, validating, and verifying... (Part I: Sec. 5, 5.1) with a check box that reads ``No U.S. Parent Company (for TRI Reporting purposes...
Harris, Chad T; Haw, Dustin W; Handler, William B; Chronik, Blaine A
2013-09-01
Eddy currents are generated in MR by the use of rapidly switched electromagnets, resulting in time varying and spatially varying magnetic fields that must be either minimized or corrected. This problem is further complicated when non-cylindrical insert magnets are used for specialized applications. Interruption of the coupling between an insert coil and the MR system is typically accomplished using active magnetic shielding. A new method of actively shielding insert gradient and shim coils of any surface geometry by use of the boundary element method for coil design with a minimum energy constraint is presented. This method was applied to shield x- and z-gradient coils for two separate cases: a traditional cylindrical primary gradient with cylindrical shield and, to demonstrate its versatility in surface geometry, the same cylindrical primary gradients with a rectangular box-shaped shield. For the cylindrical case this method produced shields that agreed with analytic solutions. For the second case, the rectangular box-shaped shields demonstrated very good shielding characteristics despite having a different geometry than the primary coils. Copyright © 2013 Elsevier Inc. All rights reserved.
CSciBox: An Intelligent Assistant for Dating Ice and Sediment Cores
NASA Astrophysics Data System (ADS)
Finlinson, K.; Bradley, E.; White, J. W. C.; Anderson, K. A.; Marchitto, T. M., Jr.; de Vesine, L. R.; Jones, T. R.; Lindsay, C. M.; Israelsen, B.
2015-12-01
CSciBox is an integrated software system for the construction and evaluation of age models of paleo-environmental archives. It incorporates a number of data-processing and visualization facilities, ranging from simple interpolation to reservoir-age correction and 14C calibration via the Calib algorithm, as well as a number of firn and ice-flow models. It employs modern database technology to store paleoclimate proxy data and analysis results in an easily accessible and searchable form, and offers the user access to those data and computational elements via a modern graphical user interface (GUI). In the case of truly large data or computations, CSciBox is parallelizable across modern multi-core processors, or clusters, or even the cloud. The code is open source and freely available on github, as are one-click installers for various versions of Windows and Mac OSX. The system's architecture allows users to incorporate their own software in the form of computational components that can be built smoothly into CSciBox workflows, taking advantage of CSciBox's GUI, data importing facilities, and plotting capabilities. To date, BACON and StratiCounter have been integrated into CSciBox as embedded components. The user can manipulate and compose all of these tools and facilities as she sees fit. Alternatively, she can employ CSciBox's automated reasoning engine, which uses artificial intelligence techniques to explore the gamut of age models and cross-dating scenarios automatically. The automated reasoning engine captures the knowledge of expert geoscientists, and can output a description of its reasoning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barbose, Galen L.; Darghouth, Naïm R.; Millstein, Dev
Now in its eighth edition, Lawrence Berkeley National Laboratory (LBNL)’s Tracking the Sun report series is dedicated to summarizing trends in the installed price of grid-connected solar photovoltaic (PV) systems in the United States. The present report focuses on residential and nonresidential systems installed through year-end 2014, with preliminary trends for the first half of 2015. As noted in the text box below, this year’s report incorporates a number of important changes and enhancements. Among those changes, this year's report focuses solely on residential and nonresidential PV systems; data on utility-scale PV are reported in LBNL’s companion Utility-Scale Solar reportmore » series. Installed pricing trends presented within this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. In total, data were collected for roughly 400,000 individual PV systems, representing 81% of all U.S. residential and non-residential PV capacity installed through 2014 and 62% of capacity installed in 2014, though a smaller subset of this data were used in analysis.« less
2017-05-12
iss051e041841 (05/12/2017) -- NASA astronaut Peggy Whitson is seen during the 200th spacewalk in support of the International Space Station. Expedition 51 Commander Peggy Whitson and Flight Engineer Jack Fischer of NASA successfully replaced a large avionics box that supplies electricity and data connections to the science experiments. The astronauts also completed additional tasks to install a connector that will route data to the Alpha Magnetic Spectrometer, repair insulation at the connecting point of the Japanese robotic arm, and install a protective shield on the Pressurized Mating Adapter-3. This adapter will host a new international docking port for the arrival of commercial crew spacecraft.
2017-05-12
iss051e041847 (05/12/2017) -- NASA astronaut Peggy Whitson is seen during the 200th spacewalk in support of the International Space Station. Expedition 51 Commander Peggy Whitson and Flight Engineer Jack Fischer of NASA successfully replaced a large avionics box that supplies electricity and data connections to the science experiments. The astronauts also completed additional tasks to install a connector that will route data to the Alpha Magnetic Spectrometer, repair insulation at the connecting point of the Japanese robotic arm, and install a protective shield on the Pressurized Mating Adapter-3. This adapter will host a new international docking port for the arrival of commercial crew spacecraft.
2017-05-12
iss051e041836 (05/12/2017) -- NASA astronaut Peggy Whitson is seen prior to the 200th spacewalk in support of the International Space Station. Expedition 51 Commander Peggy Whitson and Flight Engineer Jack Fischer of NASA successfully replaced a large avionics box that supplies electricity and data connections to the science experiments. The astronauts also completed additional tasks to install a connector that will route data to the Alpha Magnetic Spectrometer, repair insulation at the connecting point of the Japanese robotic arm, and install a protective shield on the Pressurized Mating Adapter-3. This adapter will host a new international docking port for the arrival of commercial crew spacecraft.
2017-05-12
iss051e041849 (05/12/2017) -- NASA astronaut Peggy Whitson is seen during the 200th spacewalk in support of the International Space Station. Expedition 51 Commander Peggy Whitson and Flight Engineer Jack Fischer of NASA successfully replaced a large avionics box that supplies electricity and data connections to the science experiments. The astronauts also completed additional tasks to install a connector that will route data to the Alpha Magnetic Spectrometer, repair insulation at the connecting point of the Japanese robotic arm, and install a protective shield on the Pressurized Mating Adapter-3. This adapter will host a new international docking port for the arrival of commercial crew spacecraft.
2017-05-12
iss051e041844 (05/12/2017) -- NASA astronaut Jack Fischer is seen during the 200th spacewalk in support of the International Space Station. Expedition 51 Commander Peggy Whitson and Flight Engineer Jack Fischer of NASA successfully replaced a large avionics box that supplies electricity and data connections to the science experiments. The astronauts also completed additional tasks to install a connector that will route data to the Alpha Magnetic Spectrometer, repair insulation at the connecting point of the Japanese robotic arm, and install a protective shield on the Pressurized Mating Adapter-3. This adapter will host a new international docking port for the arrival of commercial crew spacecraft.
2017-05-12
iss051e041860 (05/12/2017) -- NASA astronaut Peggy Whitson is seen during the 200th spacewalk in support of the International Space Station. Expedition 51 Commander Peggy Whitson and Flight Engineer Jack Fischer of NASA successfully replaced a large avionics box that supplies electricity and data connections to the science experiments. The astronauts also completed additional tasks to install a connector that will route data to the Alpha Magnetic Spectrometer, repair insulation at the connecting point of the Japanese robotic arm, and install a protective shield on the Pressurized Mating Adapter-3. This adapter will host a new international docking port for the arrival of commercial crew spacecraft.
NASA Technical Reports Server (NTRS)
Shain, W. M.
1976-01-01
A full scale inlet test was to be done in the NASA-ARC 40' X 80' WT to demonstrate satisfactory inlet performance at high angles of attack. The inlet was designed to match a Hamilton-Standard 55 inch, variable pitch fan, driven by a Lycoming T55-L-11A gas generator. The test was installed in the wind tunnel on two separate occasions, but mechanical failures in the fan drive gear box early in each period terminated testing. A detailed description is included of the Model, installation, instrumentation and data reduction procedures.
A minimalist approach to receiver architecture
NASA Technical Reports Server (NTRS)
Collins, O.
1991-01-01
New signal processing techniques are described for Deep Space Network radios and a proposed receiver architecture is presented, as well as experimental results on this new receiver's analog front end. The receiver's design employs direct downconversion rather than high speed digitization, and it is just as suitable for use as a space based probe relay receiver as it is for installation at a ground antenna. The advantages of having an inexpensive, shoe box size receiver, which could be carried around to antennas of opportunity, used for spacecraft testing or installed in the base of every antenna in a large array are the force behind this project.
IPv6 testing and deployment at Prague Tier 2
NASA Astrophysics Data System (ADS)
Kouba, Tomáŝ; Chudoba, Jiří; Eliáŝ, Marek; Fiala, Lukáŝ
2012-12-01
Computing Center of the Institute of Physics in Prague provides computing and storage resources for various HEP experiments (D0, Atlas, Alice, Auger) and currently operates more than 300 worker nodes with more than 2500 cores and provides more than 2PB of disk space. Our site is limited to one C-sized block of IPv4 addresses, and hence we had to move most of our worker nodes behind the NAT. However this solution demands more difficult routing setup. We see the IPv6 deployment as a solution that provides less routing, more switching and therefore promises higher network throughput. The administrators of the Computing Center strive to configure and install all provided services automatically. For installation tasks we use PXE and kickstart, for network configuration we use DHCP and for software configuration we use CFEngine. Many hardware boxes are configured via specific web pages or telnet/ssh protocol provided by the box itself. All our services are monitored with several tools e.g. Nagios, Munin, Ganglia. We rely heavily on the SNMP protocol for hardware health monitoring. All these installation, configuration and monitoring tools must be tested before we can switch completely to IPv6 network stack. In this contribution we present the tests we have made, limitations we have faced and configuration decisions that we have made during IPv6 testing. We also present testbed built on virtual machines that was used for all the testing and evaluation.
Reliability of excess-flow check-valves in turbine lubrication systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dundas, R.E.
1996-12-31
Reliability studies on excess-flow check valves installed in a gas turbine lubrication system for prevention of spray fires subsequent to fracture or separation of lube lines were conducted. Fault-tree analyses are presented for the case of failure of a valve to close when called upon by separation of a downstream line, as well as for the case of accidental closure during normal operation, leading to interruption of lubricating oil flow to a bearing. The probabilities of either of these occurrences are evaluated. The results of a statistical analysis of accidental closure of excess-flow check valves in commercial airplanes in themore » period 1986--91 are also given, as well as a summary of reliability studies on the use of these valves in residential gas installations, conducted under the sponsorship of the Gas Research Institute.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shinichi Aose; Takafumi Kitajima; Kouji Ogasawara
CPF (Chemical Processing Facility) was constructed at Nuclear Fuel Cycle Engineering Laboratories of JAEA (Japan Atomic Energy Agency) in 1980 as a basic research field where spent fuel pins from fast reactor (FR) and high level liquid waste can be dealt with. The renovation consists of remodeling of the CA-3 cell and the laboratory A, installation of globe boxes, hoods and analytical equipments to the laboratory C and the analytical laboratory. Also maintenance equipments in the CA-5 cell which had been out of order were repaired. The CA-3 cell is the main cell in which important equipments such as amore » dissolver, a clarifier and extractors are installed for carrying out the hot test using the irradiated FR fuel. Since the CPF had specialized originally in the research function for the Purex process, it was desired to execute the research and development of such new, various reprocessing processes. Formerly, equipments were arranged in wide space and connected with not only each other but also with utility supply system mainly by fixed stainless steel pipes. It caused shortage of operation space in flexibility for basic experimental study. Old equipments in the CA-3 cell including vessels and pipes were removed after successful decontamination, and new equipments were installed conformably to the new design. For the purpose of easy installation and rearranging the experimental equipments, equipments are basically connected by flexible pipes. Since dissolver is able to be easily replaced, various dissolution experiments is conducted. Insoluble residue generated by dissolution of spent fuel is clarified by centrifugal. This small apparatus is effective to space-saving. Mini mixer settlers or centrifugal contactors are put on to the prescribed limited space in front of the backside wall. Fresh reagents such as solvent, scrubbing and stripping solution are continuously fed from the laboratory A to the extractor by the reagent supply system with semi-automatic observation system. The in-cell crane in CA-5 was renovated to increase driving efficiency. At the renovation for the in-cell crane, full scale mockup test and 3D simulation test had been executed in advance. After the renovation, hot tests in the CPF had been resumed from JFY 2002. New equipments such as dissolver, extractor, electrolytic device, etc. were installed in CA-3 conformably to the new design laid out in order to ensure the function and space. Glove boxes in the analysis laboratory were renewed in order to let it have flexibility from the viewpoint of conducting basic experiments (ex. U crystallization). Glove boxes and hoods were newly installed in the laboratory A for basic research and analysis, especially on MA chemistries. One laboratory (the laboratory C) was established to research about dry reprocessing. The renovation of the CPF has been executed in order to contribute to the development on the advanced fast reactor fuel cycle system, which will give us many sort of technical subject and experimental theme to be solved in the 2. Generation of the CPF.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... for Marine Fire Applications, (approved March 1, 2010) 126.15 National Fire Protection Association (NFPA), One Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101: NFPA 10, Standard for Portable Fire Extinguishers, 1998 Edition 126.15 NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 Edition 126...
Code of Federal Regulations, 2013 CFR
2013-07-01
... for Marine Fire Applications, (approved March 1, 2010) 126.15 National Fire Protection Association (NFPA), One Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101: NFPA 10, Standard for Portable Fire Extinguishers, 1998 Edition 126.15 NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 Edition 126...
Code of Federal Regulations, 2010 CFR
2010-07-01
... accumulate on electrical installations, wiring shall be in rigid conduit or in boxes containing no taps... pressure. (12) Wiring, motors and equipment in a spray booth shall be of approved explosion-proof type for..., Hazardous Locations. Wiring, motors and equipment within 20 feet (6.1m) of any interior spraying area and...
Helium Transfer System for the Superconducting Devices at NSRRC
NASA Astrophysics Data System (ADS)
Li, H. C.; Hsiao, F. Z.; Chang, S. H.; Chiou, W. S.
2006-04-01
A helium cryogenic plant with a maximum cooling power of 450 W at 4.5K was installed at the end of the year 2003. This plant has provide the cooling power for the test of one superconducting cavity and the commission of one superconducting magnet for nine months. In November 2004, we installed one helium transfer system in NSRRC's storage ring to fulfill the cooling requirement for the operation of one superconducting cavity and two superconducting magnets. This helium transfer system consists of a switch valve box and the nitrogen-shielding multi-channel transfer lines. The averaged heat leak to the helium process line (including the straight section, the joint, the elbow, the coupling) at liquid helium temperature is specified to be less than 0.1 W/m at 4.2K; the total heat leak of the switching valve box to helium process lines is less than 16 W at 4.2K. In this paper we present the function, design parameters and test result of the helium transfer system. Commissioning results of both the cavity and the magnets using this helium transfer system will be shown as well.
Reducing Undue Conservatism in "Higher Frequency" Structural Design Loads in Aerospace Components
NASA Technical Reports Server (NTRS)
Knight, J. Brent
2012-01-01
This study is intended to investigate the frequency dependency of significant strain due to vibratory loads in aerospace vehicle components. The notion that "higher frequency" dynamic loads applied as static loads is inherently conservative is perceived as widely accepted. This effort is focused on demonstrating that principle and attempting to evolve methods to capitalize on it to mitigate undue conservatism. It has been suggested that observations of higher frequency modes that resulted in very low corresponding strain did so due to those modes not being significant. Two avionics boxes, one with its first significant mode at 341 Hz and the other at 857 Hz, were attached to a flat panel installed on a curved orthogrid panel which was driven acoustically in tests performed at NASA/MSFC. Strain and acceleration were measured at select locations on each of the boxes. When possible, strain gage rosettes and accelerometers were installed on either side of a given structural member so that measured strain and acceleration data would directly correspond to one another. Ultimately, a frequency above which vibratory loads can be disregarded for purposes of static structural analyses and sizing of typical robust aerospace components is sought.
Thermal Response Testing Takes a Step Forward
Clemenzi, Rick; Ewbank, Garen; Siglin, Judy; ...
2017-09-01
Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout jobmore » of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects« less
Thermal Response Testing Takes a Step Forward
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clemenzi, Rick; Ewbank, Garen; Siglin, Judy
Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout jobmore » of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects« less
Helicopter internal noise control: Three case histories
NASA Technical Reports Server (NTRS)
Edwards, B. D.; Cox, C. R.
1978-01-01
Case histories are described in which measurable improvements in the cabin noise environments of the Bell 214B, 206B, and 222 were realized. These case histories trace the noise control efforts followed in each vehicle. Among the design approaches considered, the addition of a fluid pulsation damper in a hydraulic system and the installation of elastomeric engine mounts are highlighted. It is concluded that substantial weight savings result when the major interior noise sources are controlled by design, both in altering the noise producing mechanism and interrupting the sound transmission paths.
Isolation contactor state control system
Bissontz, Jay E.
2017-05-16
A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.
The Design of Pressure Safety Systems in the Alumina Industry
NASA Astrophysics Data System (ADS)
Haneman, Brady
The alumina refinery presents the designer with multiple challenges. For a given process flowsheet, the mechanical equipment installed must be routinely inspected and maintained. Piping systems must also be inspected routinely for signs of erosion and/or corrosion. Rapid deposits of chemical species such as lime, silica, and alumina on equipment and piping need special consideration in the mechanical design of the facilities, such that fluid flows are not unduly interrupted. Above and beyond all else, the process plant must be a safe place of work for refinery personnel.
SNS Central Helium Liquefier spare Carbon Bed installation and commissioning
NASA Astrophysics Data System (ADS)
DeGraff, B.; Howell, M.; Kim, S.; Neustadt, T.
2017-12-01
The Spallation Neutron Source (SNS) Central Helium Liquefier (CHL) at Oak Ridge National Laboratory (ORNL) has been without major operations downtime since operations were started back in 2006. This system utilizes a vessel filled with activated carbon as the final major component to remove oil vapor from the compressed helium circuit prior to insertion into the system’s cryogenic cold box. The need for a spare carbon bed at SNS due to the variability of carbon media lifetime calculation to adsorption efficiency will be discussed. The fabrication, installation and commissioning of this spare carbon vessel will be presented. The novel plan for connecting the spare carbon vessel piping to the existing infrastructure will be presented.
NASA Astrophysics Data System (ADS)
Casagrande, F.; Ganni, V.; Knudsen, P.; Jones, S.; Sidi-Yekhlef, A.; Tatsumoto, H.; Nguyen, C.; Fila, A.; Vargas, G.; Dudley, C.; Joseph, N.; Stanley, S.; Dixon, K.; Norton, R.; Laverdure, N.; Yang, S.
2017-12-01
Construction and installation of the FRIB 4.5 K helium refrigeration system is nearing completion, with compressor system commissioning and 4.5 K refrigerator commissioning on schedule to occur in late 2017. The LINAC 4.5 K helium distribution system, all major process equipment, and the cryogenic distribution for the sub-systems have been procured and delivered. The sub-atmospheric cold box fabrication is planned to begin the summer of 2017, which is on schedule for commissioning in the spring of 2018. Commissioning of the support systems, such as the helium gas storage, helium purifier, and oil processor is planned to be complete by the summer of 2017. This paper presents details of the equipment procured, installation status and commissioning plans.
2009-02-01
power battery box and controllers, WiFi radio, network switch, vault seismometers, infrasonic digitizers, and excess cabling. In addition to the...installed around the boreholes. Immediately upon completion, each site will be cleared of all unused equipment, debris, materials, and trash . All...controllers, WiFi radio, network switch, vault seismometers, infrasonic digitizers, and excess cabling. In addition to the permanent infrastructure listed
HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant
2016-09-01
material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... flex-hoses of the crew oxygen system installed under the oxygen mask stowage boxes in the flight deck... results from reports of low-pressure flex- hoses of the crew oxygen system that burned through due to... prevent inadvertent electrical current, which can cause the low-pressure flex-hoses of the crew oxygen...
Installation Restoration Program. Phase 1. Records Search, England AFB, Louisiana
1983-05-01
compound shown on Figure 4.3. No herbicides, expired DDT or other pesticides were stored at this site. Some battery acid was stored in plastic boxes...Union Carbide Corporation, Chemicals and Plastics Divi- sion, Environomental Engineering Department. As a pro- cess/project engineer performed...paper mill waste treatment facility. Project Manager on Solid and Hazardous Waste study for a diverse chemicals and plastics production facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barbose, Galen; Darghouth, Naïm; Millstein, Dev
Now in its ninth edition, Lawrence Berkeley National Laboratory (LBNL)’s Tracking the Sun report series is dedicated to summarizing trends in the installed price of grid-connected solar photovoltaic (PV) systems in the United States. The present report focuses on residential and non-residential systems installed through year-end 2015, with preliminary trends for the first half of 2016. An accompanying LBNL report, Utility-Scale Solar, addresses trends in the utility-scale sector. This year’s report incorporates a number of important changes and enhancements from prior editions. Among those changes, LBNL has made available a public data file containing all non-confidential project-level data underlying themore » analysis in this report. Installed pricing trends presented within this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. Refer to the text box to the right for several key notes about these data. In total, data were collected and cleaned for more than 820,000 individual PV systems, representing 85% of U.S. residential and non-residential PV systems installed cumulatively through 2015 and 82% of systems installed in 2015. The analysis in this report is based on a subset of this sample, consisting of roughly 450,000 systems with available installed price data.« less
Evaluation of numerical models by FerryBox and Fixed Platform in-situ data in the southern North Sea
NASA Astrophysics Data System (ADS)
Haller, M.; Janssen, F.; Siddorn, J.; Petersen, W.; Dick, S.
2015-02-01
FerryBoxes installed on ships of opportunity (SoO) provide high-frequency surface biogeochemical measurements along selected tracks on a regular basis. Within the European FerryBox Community, several FerryBoxes are operated by different institutions. Here we present a comparison of model simulations applied to the North Sea with FerryBox temperature and salinity data from a transect along the southern North Sea and a more detailed analysis at three different positions located off the English East coast, at the Oyster Ground and in the German Bight. In addition to the FerryBox data, data from a Fixed Platform of the MARNET network are applied. Two operational hydrodynamic models have been evaluated for different time periods: results of BSHcmod v4 are analysed for 2009-2012, while simulations of FOAM AMM7 NEMO have been available from MyOcean data base for 2011 and 2012. The simulation of water temperatures is satisfying; however, limitations of the models exist, especially near the coast in the southern North Sea, where both models are underestimating salinity. Statistical errors differ between the models and the measured parameters, as the root mean square error (rmse) accounts for BSHcmod v4 to 0.92 K, for AMM7 only to 0.44 K. For salinity, BSHcmod is slightly better than AMM7 (0.98 and 1.1 psu, respectively). The study results reveal weaknesses of both models, in terms of variability, absolute levels and limited spatial resolution. In coastal areas, where the simulation of the transition zone between the coasts and the open ocean is still a demanding task for operational modelling, FerryBox data, combined with other observations with differing temporal and spatial scales serve as an invaluable tool for model evaluation and optimization. The optimization of hydrodynamical models with high frequency regional datasets, like the FerryBox data, is beneficial for their subsequent integration in ecosystem modelling.
NASA Astrophysics Data System (ADS)
Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming
2016-11-01
Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.
Development of locomotor activity of rat pups in figure-eight mazes.
Ruppert, P H; Dean, K F; Reiter, L W
1985-05-01
In a series of four experiments, social and experiential factors that influence the development of motor activity in rat pups were examined. Motor activity was monitored from postnatal Days 13 to 21 as photocell interruptions in figure-eight mazes and comparisons were made between pups maintained in a nest box containing a dam and siblings and allowed access to the maze for 23 hr/day, pups tested daily for 1 hr/day vs pups tested only on postnatal Days 15, 18, or 21, pups tested daily for either 5 min, 30 min, or 1 hr/day, and pups tested daily for 30 min/day either singly in a maze, paired with a littermate, or paired with an anesthetized pup of the same age. A monotonic increase in activity was seen for nest-box testing, minimal developmental change was seen for pups tested on only a single day or for pups tested with an anesthetized pup, whereas all other groups showed an inverted U-shaped profile of activity which was influenced by the duration of testing and/or the presence of a littermate. These data emphasize the relevance of environmental factors as determinants of preweaning behavior.
Vaccine refrigeration: thinking outside of the box.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator with a battery back-up power supply and microprocessor control system is also described.
Cistern and planter box monitoring in Camden, NJ revisited ...
The Camden County Municipal Utilities Authority installed green infrastructure Stormwater Control Measures at multiple locations around the city of Camden, NJ. The Stormwater Control Measures include raised downspout planter boxes and cisterns. EPA is monitoring a subset of the locations to document the performance of individual Stormwater Control Measures. The selected monitoring sites include two sets of raised downspout planter boxes and five cisterns. These Stormwater Control Measures are being monitored: to investigate their hydrologic performances, to document water consumption patterns of cisterns for a better understanding of the supply and demand relationship, and to analyze cistern water quality. The continuous electronic monitoring devices included time domain reflectometers, rain gauges and pressure transducers. EPA decided to monitor these Stormwater Control Measures for three years and second year monitoring is ongoing. Monitoring data present the internal water flow patterns and media saturation frequency of the raised planter boxes and the capture ratio, water use patterns and water quality analysis of cisterns. Second year monitoring shows larger capture ratio for cisterns compared to the first year data and higher metal concentration at one site. The high metal concentration was later resolved by flushing the cistern and resampling. The presentation will summarize the comparison between first and second year data, providing results from the
Feasibility of white-rot fungi for biodegradation of PCP-treated ammunition boxes. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholze, R.J.; Lamar, R.T.; Bolduc, J.
1995-01-01
Millions of pounds of wood ammunition boxes treated with the wood preservative pentachiorophenol (PCP) are being stockpiled at military installations, primarily depots, because cost-effective disposal is not readily available. The Army needs cost-effective and environmentally benign treatment methods for destruction and disposal of PCP-treated wood products. This research investigated the use of white-rot fungi to biodegrade PCP-treated wood. Results showed that white-rot fungi effectively decreased the PCP concentration in contaminated hardwood and softwood chips. Under ideal laboratory conditions the fungi reduced the PCP concentration by 80 percent; a field study showed only a 30 percent decrease in PCP concentration. Despitemore » this disparity, this study demonstrated the feasibility of using white-rot fungi to reduce PCP in treated wood.« less
Sassi, C G; Cameli, M; Dokollari, A; Diciolla, F; Scolletta, S; Ricci, C; Lucatelli, P; Mondillo, S; Maccherini, M
2017-05-01
There are limited clinical reports concerning internal power cable fixing in left ventricular assist device (L-VAD) patients. Actually there are no reports in the literature about Jarvik 2000 internal cable repair. We show the first description of a technique for surgical reparation of such a fatal complication. The patient was a 62-year-old woman who had L-VAD implantation (Jarvik 2000) with outflow graft apposition in descending thoracic aorta through left thoracotomy access, in 2009. She arrived urgently on January 25, 2014 for Jarvik 2000 dysfunction correlated with head movements. The neck X-rays revealed the rupture of one of the nine power cables located inside the neck and the damaging of two more cables nearby to be ruptured. On the same day she got pump failure due to the final interruption of the remaining two cables, we were obliged to install femoro-femoral extracorporeal membrane oxygenation (ECMO) assistance, to repair the power cables, approaching them through a pacemaker extension cable. The L-VAD outflow was occluded with vascular ball occluder inserted via right axillary artery under fluoroscopy before ECMO installation. At the end the ECMO assistance was interrupted and the Jarvik 2000 was turned back on. The patient was dismissed from the hospital 12 days after the procedure. At the moment the international literature is poor regarding this issue. This case provides evidence that in emergency conditions ECMO assistance is mandatory and a hybrid surgical and radiological approach could help to repair the damage in safe conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
Effect of heart checks on flexural properties of reclaimed 6 by 8 Douglas-fir timbers
David W. Green; Robert H. Falk; Scott F. Lantz
2001-01-01
A sampling of nominal 6- by 8-inch (standard 140- by 184-mm) Douglas-fir timbers was obtained from an industrial military building in Minnesota. Thirty selected timbers had heart checks (boxed heart splits), which are characteristic of most old timbers installed in dry locations. Sixty selected timbers did not have heart checks. Most of the beams would grade as Select...
Parenting Outside the Box, Part Three: The New “Normal” | Poster
Editor’s Note: This article is the final installment in a series describing one NCI at Frederick parent’s perspective on special needs parenting. Part one can be found here, and part two can be found here. Parents of special-needs children do their best to help their kids thrive in typical society, but at times this can be challenging. For instance, I want my son, Harrison, to
1986-06-01
63’ Reference Date Tinx- Point Elevation: Drilling Started:11/8/84 1330hrs Drillinz Cornpleted:11/12/84 1100 Site Sketch Waer Leel: 13.5’ 11/9/84 0900...Box 1401 TELEPHONE (302) 736 4761I DOVER. DELAWARE 1 9903 I MEMORANDUM 3 TO: Mr. Kevin Burdette FROM: Philip J. Cherry’j DATE: October 22, 1984 The
2013-12-23
the CnC drive, building and integration of the plasma head, installation of gas distribution system, and control systems for the machine. The machine...Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 antimicrobial coatings, atmospheric pressure plasma liquid deposition...polyester fabric using Triton Systems novel atmospheric pressure plasma deposition process (Invexus™). It is envisioned that these new antimicrobial
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
... low-pressure flex-hoses of the crew oxygen system installed under the oxygen mask stowage boxes in the.... This proposed AD results from reports of low-pressure flex-hoses of the crew oxygen system that burned... the crew oxygen system to melt or burn, causing oxygen system leakage and smoke or fire. DATES: We...
Installation and pre-commissioning of the cryogenic system of JT-60SA tokamak
NASA Astrophysics Data System (ADS)
Hoa, C.; Michel, F.; Roussel, P.; Fejoz, P.; Girard, S.; Goncalves, R.; Lamaison, V.; Natsume, K.; Kizu, K.; Koide, Y.; Yoshida, K.; Cardella, A.; Portone, A.; Verrecchia, M.; Wanner, M.; Beauvisage, J.; Bertholat, F.; Gaillard, G.; Heloin, V.; Langevin, B.; Legrand, J.; Maire, S.; Perrier, J. M.; Pudys, V.
2017-02-01
The cryogenic system for the superconducting tokamak JT-60SA is currently being commissioned in Naka, Japan and shall be ready for operation in summer 2016. This contribution is part of the Broader Approach agreement between Japan and Europe. With an equivalent refrigeration capacity of about 9.5 kW at 4.5 K the cryogenic system will supply cryo-pump panels at 3.7 K, superconducting magnets and their structures at 4.4 K, high temperature superconducting current leads at 50 K and thermal shields between 80 K and 100 K. The system has been specifically designed to handle large pulse loads at 4.4 K during plasma operation. The mechanical and electrical assembly of the cryogenic system has been achieved within six months by October 2015. The main contractor Air Liquide Advanced Technology (AL-aT) have supplied eight parallel working screw compressors with a common oil removal and dryer system, a Refrigeration Cold Box and an Auxiliary Cold box with cold rotating machines. F4E has provided six GHe storage vessels and QST has provided the complete infrastructure and the facilities for the utilities. The paper gives an overview of the main design features, the infrastructure and the status of installation and pre-commissioning.
The efficiency of gravity distribution devices for on-site wastewater treatment systems.
Patel, T; O'Luanaigh, N; Gill, L W
2008-01-01
A detailed analysis of different types of gravity distribution devices, designed to split on-site wastewater effluent equally between percolation trenches, has been carried out both in the laboratory and also in the field under realistic loading conditions. Five different types of distribution device have been compared: a V-notch distribution box, stilling chamber box, T-splitters with and without baffles and tipping bucket device. The trials carried out in the laboratory with clean water showed that flow distribution for all devices was sensitive to both the off-level installation angles and variable flow rates, with the most stable performance achieved using the T-splitters with baffles and tipping bucket devices. In parallel to this, the on-site flow regime experienced at two sites was continuously monitored using a tipping bucket and data-logger over eighteen month periods, finding that the most common flow rates at the distribution unit were in the range of 0.1-2.5 L/min. The on-site performance of these devices receiving both septic tank and secondary treated effluent showed that significant solid deposition and biofilm development had severely affected the equal distribution between the trenches, hence highlighting the need for regular maintenance to ensure efficient performance over time after installation. IWA Publishing 2008.
NASA Technical Reports Server (NTRS)
Lee, Sangwoo; Miller, David O.; Schwemmer, Geary; Wilkerson, Thomas D.; Andrus, Ionio; Egbert, Cameron; Anderson, Mark; Starr, David OC. (Technical Monitor)
2002-01-01
Background noise reduction of War signals is one of the most important factors in achieving better signal to noise ratio and precise atmospheric data from Mar measurements. Fahey Perot etalons have been used in several lidar systems as narrow band pass filters in the reduction of scattered sunlight. An slalom with spectral bandwidth, (Delta)v=0.23/cm, free spectral range, FSR=6.7/cm, and diameter, d=24mm was installed in a fiber coupled box which included a 500 pm bandwidth interference Filter. The slalom box couples the telescope and detector with 200 pm core fibers and 21 mm focal length collimators. The angular magnification is M=48. The etalon box was inserted into the Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE) system and tested during the HARGLO-2 intercomparison campaign conducted in November 2001 at Wallops Island, Virginia. This paper presents the preliminary test results of the slalom and a complete analysis will be presented at the conference.
Research of intelligent bus coin box
NASA Astrophysics Data System (ADS)
Xin, Shihao
2017-03-01
In the energy-saving emission reduction of the social context, in response to low-carbon travel, buses become the majority of people choose. We have designed this sorting machine for the present situation that the bus company has received a large amount of mixed zero coins and employed a large amount of manpower to sort out and lower the efficiency. Its function is to separate the coins and notes mixed, and the coins sort storage, the display shows the value of the received coins, so that the whole mechanized inventory classification, reduce the cost of clearing up and improve the efficiency of zero cash recycling, use Simple mechanical principles for classification, to be efficient, accurate and practical. Really meet the current city bus companies, commerce and banking and other industries in order to zero notes, zero coins in the actual demand. The size and specification of this machine are designed according to the size of the bus coin box. It is suitable for almost all buses. It can be installed in the coin box directly, real-time sorting and real-time counting. The difficulty of clearing change.
SNS Central Helium Liquefier spare Carbon Bed installation and commissioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Degraff, Brian D.; Howell, Matthew P.; Kim, Sang-Ho
The Spallation Neutron Source (SNS) Central Helium Liquefier (CHL) at Oak Ridge National Laboratory (ORNL) has been without major operations downtime since operations were started back in 2006. This system utilizes a vessel filled with activated carbon as the final major component to remove oil vapor from the compressed helium circuit prior to insertion into the system's cryogenic cold box. The need for a spare carbon bed at SNS due to the variability of carbon media lifetime calculation to adsorption efficiency will be discussed. The fabrication, installation and commissioning of this spare carbon vessel will be presented. The novel planmore » for connecting the spare carbon vessel piping to the existing infrastructure will be presented.« less
Lightning protection of a modern wind energy system
NASA Astrophysics Data System (ADS)
Jaeger, D.
Due to their considerable height and frequent location above flat terrain, wind energy systems may be struck by lightning, with two types of severe effects: the physical destruction of structurally and/or mechanically important elements, such as a rotor blade, or the damage or interruption of system electrical and electronic equipment. The GROWIAN II DEMO lightning protection program has undertaken the development of measures which in their sophistication and complexity approximate those for aircraft. These protective measures are applied to the carbon fiber-reinforced plastic composite rotor blades, the rotor bearing, and electrical circuitry installed within the wind turbine's nacelle.
Modular Seafloor and Water Column Systems for the Ocean Observatories Initiative Cabled Array
NASA Astrophysics Data System (ADS)
Delaney, J. R.; Manalang, D.; Harrington, M.; Tilley, J.; Dosher, J.; Cram, G.; Harkins, G.; McGuire, C.; Waite, P.; McRae, E.; McGinnis, T.; Kenney, M.; Siani, C.; Michel-Hart, N.; Denny, S.; Boget, E.; Kawka, O. E.; Daly, K. L.; Luther, D. S.; Kelley, D. S.; Milcic, M.
2016-02-01
Over the past decade, cabled ocean observatories have become an increasingly important way to collect continuous real-time data at remote subsea locations. This has led to the development of a class of subsea systems designed and built specifically to distribute power and bandwidth among sensing instrumentation on the seafloor and throughout the water column. Such systems are typically powered by shore-based infrastructure and involve networks of fiber optic and electrical cabling that provide real-time data access and control of remotely deployed instrumentation. Several subsea node types were developed and/or adapted for cabled use in order to complete the installation of the largest North American scientific cabled observatory in Oct, 2014. The Ocean Observatories Initiative (OOI) Cabled Array, funded by the US National Science Foundation, consists of a core infrastructure that includes 900 km of fiber optic/electrical cables, seven primary nodes, 18 seafloor junction boxes, three mooring-mounted winched profiling systems, and three wire-crawling profiler systems. In aggregate, the installed infrastructure has 200 dedicated scientific instrument ports (of which 120 are currently assigned), and is capable of further expansion. The installed system has a 25-year design life for reliable, sustained monitoring; and all nodes, profilers and instrument packages are ROV-serviceable. Now in it's second year of operation, the systems that comprise the Cabled Array are providing reliable, 24/7 real-time data collection from deployed instrumentation, and offer a modular and scalable class of subsea systems for ocean observing. This presentation will provide an overview of the observatory-class subsystems of the OOI Cabled Array, focusing on the junction boxes, moorings and profilers that power and communicate with deployed instrumentation.
STS-109 Mission Highlights Resource Tape
NASA Astrophysics Data System (ADS)
2002-05-01
This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.
NASA Astrophysics Data System (ADS)
Naito, Yuji; Shimizu, Iwao; Yamaguchi, Iwao; Kaiho, Katsuyuki; Yanabu, Satoru
Using high temperature superconductor, a Superconducting Fault Current Limiter (SFCL) was made and tested. Superconductor and vacuum interrupter as commutation switch are connected in parallel with bypass coil. When a fault occurs and the excessive current flows, superconductor is first quenched and the current is transferred to bypass coil because on voltage drop of superconductor. At the same time, since magnetic field is generated by current which flows in bypass coil, commutation switch is immediately driven by electromagnetic repulsion plate connected to driving rod of vacuum interrupter, and superconductor is separated from this circuit. Using the testing model, we could separate the superconductor from a circuit due to movement of vacuum interrupter within half-cycle current and transfer all current to bypass coil. Since operation of a commutation switch is included in current limiting operation of this testing model, it is one of helpful circuit of development of SFCL in the future. Moreover, since it can make the consumed energy of superconductor small during fault state due to realization of high-speed switch with simple composition, the burden of superconductor is reduced compared with conventional resistive type SFCL and it is considered that the flexibility of a SFCL design increases. Cooperation with a circuit breaker was also considered, the trial calculation of a parameter and energy of operation is conducted and discussion in the case of installing the SFCL to electric power system is made.
10. Photocopied August 1978. CLOSEUP VIEW OF TURBINE SHAFT PENETRATING ...
10. Photocopied August 1978. CLOSE-UP VIEW OF TURBINE SHAFT PENETRATING THE STEEL PLATE BULKHEAD THROUGH A STUFFING BOX AND AND ALSO SHOWING THE CONTROL GATE SHAFT. THIS PARTICULAR UNIT WAS INSTALLED IN 1916. THE ADMISSION OF WATER TO ALL FOUR RUNNERS IN A PENSTOCK UNIT COULD SIMULTANEOUSLY BE CONTROLLED BY THE CONTROL SHAFT ON THE LEFT. (899) - Michigan Lake Superior Power Company, Portage Street, Sault Ste. Marie, Chippewa County, MI
ARRANGEMENT FOR REPLACING FILTERS
Blomgren, R.A.; Bohlin, N.J.C.
1957-08-27
An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.
Impact of PID on industrial rooftop PV-installations
NASA Astrophysics Data System (ADS)
Buerhop, Claudia; Fecher, Frank W.; Pickel, Tobias; Patel, Tirth; Zetzmann, Cornelia; Camus, Christian; Hauch, Jens; Brabec, Christoph J.
2017-08-01
Potential induced degradation (PID) causes severe damage and financial losses even in modern PV-installations. In Germany, approximately 19% of PV-installations suffer from PID and resulting power loss. This paper focuses on the impact of PID in real installations and how different evaluated time intervals influence the performance ratio (PR) and the determined degradation rate. The analysis focuses exemplarily on a 314 kWp PV-system in the Atlantic coastal climate. IR-imaging is used for identifying PID without operation interruption. Historic electric performance data are available from a monitoring system for several years on system level, string level as well as punctually measured module string IV- curves. The data sets are combined for understanding the PID behavior of this PV plant. The number of PID affected cells within a string varies strongly between 1 to 22% with the string position on the building complex. With increasing number of PID-affected cells the performance ratio decreases down to 60% for daily and monthly periods. Local differences in PID evolution rates are identified. An average PR-reduction of -3.65% per year is found for the PV-plant. On the string level the degradation rate varied up to 8.8% per year depending on the string position and the time period. The analysis reveals that PID generation and evolution in roof-top installations on industrial buildings with locally varying operation conditions can be fairly complex. The results yield that local operating conditions, e.g. ambient weather conditions as well as surrounding conditions on an industrial building, seem to have a dominating impact on the PID evolution rate.
Energy saver A-sector power test results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, P.; Flora, R.; Tool, G.
1982-09-15
The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied bymore » three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.« less
2009-07-01
BET, helium pycnometer, particle size laser scattering analysis, X-ray diffraction, TGA, DSC, calorimeter, etc.) • Initiated manufacturing of...boxes are then packed into a one-gallon aluminum paint can along with sufficient padding, after which the lid is installed in the usual manner. The... paint cans are stored for later use in a magazine without temperature and humidity control. In a typical lot of 10,000 primers, 900 are immediately
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, R.J.
1997-07-01
This narrative addresses the development of the subsea flexible pipe catenary handling tools and procedures as used in the Gulf of Mexico on the Enserch Garden Banks 388 Freestanding Production Riser. The philosophy that was invoked for the development of the tools and procedures was targeted on long term utilization and field maintenance capability with minimum vessel relocation requirements and minimum production interruptions. The initial emphasis for the required tools and procedures was to develop worker safe, environmentally friendly and cost effective equipment. These tools are for the deployment and installation of 3-inch Production and Annulus flexible pipe catenaries frommore » the Enserch Garden Banks 388 Floating Production Vessel to the system`s Freestanding Production Riser. The Pull In Jib system is common to the handling of all the catenaries. The Pull In Jib system has been designed to support the greater loads of the 8-inch and 12-inch export line catenaries.« less
Aeroelastic performance evaluation of a flexure box morphing airfoil concept
NASA Astrophysics Data System (ADS)
Pankonien, Alexander M.; Inman, Daniel J.
2014-04-01
The flexure-box morphing aileron concept utilizes Macro-Fiber Composites (MFCs) and a compliant box to create a conformal morphing aileron. This work evaluates the impact of the number of MFCs on the performance, power and mass of the aileron by experimentally investigating two different actuator configurations: unimorph and bimorph. Implemented in a NACA 0012 airfoil with 304.8 mm chord, the unimorph and bimorph configurations are experimentally tested over a range of flow speeds from 5 to 20 m/s and angles of attack from -20 to 20 degrees under aerodynamic loads in a wind tunnel. An embedded flexible sensor is installed in the aileron to evaluate the effect of aerodynamic loading on tip position. For both design choices, the effect of actuation on lift, drag and pitching moment coefficients are measured. Finally, the impact on aileron mass and average power consumption due to the added MFCs is considered. The results showed the unimorph exhibiting superior ability to influence flow up to 15 m/s, with equivalent power consumption and lower overall mass. At 20 m/s, the bimorph exhibited superior control over aerodynamic forces and the unimorph experienced significant deformation due to aerodynamic loading.
Prediction on flexural strength of encased composite beam with cold-formed steel section
NASA Astrophysics Data System (ADS)
Khadavi, Tahir, M. M.
2017-11-01
A flexural strength of composite beam designed as boxed shaped section comprised of lipped C-channel of cold-formed steel (CFS) facing each other with reinforcement bars is proposed in this paper. The boxed shaped is kept restrained in position by a profiled metal decking installed on top of the beam to form a slab system. This profiled decking slab is cast by using self-compacting concrete where the concrete is in compression when load is applied to the beam. Reinforcement bars are used as shear connector between slab and CFS as beam. A numerical analysis method proposed by EC4 is used to predict the flexural strength of the proposed composite beam. It was assumed that elasto-plastic behaviour is developed in the cross -sectional of the proposed beam. The calculated predicted flexural strength of the proposed beam shows reasonable flexural strength for cold-formed composite beam.
High Speed Solid State Circuit Breaker
NASA Technical Reports Server (NTRS)
Podlesak, Thomas F.
1993-01-01
The U.S. Army Research Laboratory, Fort Monmouth, NJ, has developed and is installing two 3.3 MW high speed solid state circuit breakers at the Army's Pulse Power Center. These circuit breakers will interrupt 4160V three phase power mains in no more than 300 microseconds, two orders of magnitude faster than conventional mechanical contact type circuit breakers. These circuit breakers utilize Gate Turnoff Thyristors (GTO's) and are currently utility type devices using air cooling in an air conditioned enclosure. Future refinements include liquid cooling, either water or two phase organic coolant, and more advanced semiconductors. Each of these refinements promises a more compact, more reliable unit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, R. J.; Ahn, J.W.; Bortolon, A.
The twelve-strap high-harmonic fast-wave (HHFW) antenna on NSTX has exhibited a high-voltage standoff around 25 kV during previous experimental campaigns; this standoff needs to be improved for increased power coupling. During the recent NSTX-U upgrade period, a test-stand was set up with two antenna straps along with Faraday screens for testing purposes. Using a diagnostic suite consisting of a fast camera, a residual gas analyzer, a pressure gage, high-voltage probes, and an infrared camera, several interesting discoveries were made, leading to possible improvements of the antenna RF voltage operation level. First, arcing was observed outside the Faraday shields towards themore » low-voltage ("grounded") end of the straps (faraday shield box ends); this arcing was successfully eliminated by installing an additional grounding point between the Faraday shield box and the vessel wall. Second, considerable outgassing was observed during the RF pulse and the amount of outgassing was found to decrease with increasing RF power, possibly indicative of multipacting. Finally, infrared camera measurements of heating on the Faraday shield assembly suggest that the return currents on the Faraday shield box are highly localized at the box sides and possibly account for the pressure increase observed. Computations of these RF currents using Microwave Studio show qualitative agreement with the heated regions. New grounding points between the antenna box and the vessel have been implemented in NSTX-U, where future tests will be done to determine if the high-voltage standoff has improved. Further antenna improvements will be sought through future experiments on the test stand.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-04-01
When piping develops leaks, the natural instinct is to shut the process down, purge the lines and call in maintenance crews to make the repairs. There is, however, an alternative: on-the-fly repairs. Through the use of specialized tools, equipment and technicians, shut-off valves can be installed and leaks repaired without interrupting production. The split sleeve offers one of the simpler approaches to on-the-fly repairs. Two half cylinders with inside diameter slightly larger than the outside diameter slightly larger than the outside diameter of the pipe to be repaired are slipped over the latter some distance form the leak and looselymore » bolted together. The cylinder is then slid over the leaking area and the bolts tightened. Gaskets inside the half cylinders provide the needed seal between the pipe and the cylinder. Installing a shut-off valve in an operating pipeline requires much more specialized equipment and skills than does repairing a leak with a split sleeve. A device available from International Piping Services Co. allows a trained crew to isolate a section of pipe, drill out the isolated portion, install a blocking valve and then remove the isolation system--all while continuing to operate the pipeline at temperatures to 700 F and pressures to 700 psi. But Herb Porter, CEO of Ipsco, cautions that unlike the repairing leaks with a split sleeve, installing a blocking valve on-the-fly always demands the services of a highly trained crew.« less
Field Trial of an Aerosol-Based Enclosure Sealing Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, Curtis; Springer, David
2015-09-01
This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology. However, this technology is capable of bringing the air leakage of a building that was built with standard construction techniques and HERS-verified sealing down to levels that would meet DOE Zero Energy Ready Homes program requirements. When a developer is striving to meet a tighter envelope leakage specification, this technology could greatly reduce the cost to achieve that goal by providing a simple and relatively low cost method for reducing the air leakage of a building envelope with little to no change in their common building practices.« less
2018-02-02
iss054e027048 (Feb. 2, 2018) --- A Russian spacewalker is seen in an Orlan spacesuit with blue stripes (center image) working outside the Zvezda service module during the longest spacewalk in Russian space program history on Feb. 2, 2018. Cosmonauts Alexander Misurkin and Anton Shkaplerov wrapped up the eight hour and 13 minute spacewalk after installing a new electronics and telemetry box for the high gain antenna on Zvezda. The new gear will enhance communications between Russian flight controllers and the Russian modules.
Installation Restoration Program Phase 2. Confirmation/Quantification. Stage 1. Volume 1.
1986-10-10
FIGUR 1- EEA LNO EFIG I AiNLanfl GUARD BASESHOWING PHSE II INVTIGTOIE I 1- ........ Site No. - I MAA Site No.Northwest Landfill TS Site.No.4 West...Protective Steel PVC Cap Flush Mount in Casing Plastic Nelson Valve Box Land Surface PVC Cap . Cement Grout 0 L n aBentonite Pellet 4" Diameter Seal...12.0 feet BLS. Clays of high plasticity predominate in all three wells. No sand lenses were encountered and the topsoil at all three well locations is
Final Environmental Assessment for Installation Development at Little Rock Air Force Base Arkansas
2006-10-18
southwest corners of the base. Long, narrow ridges, oriented from east to west, typify the region to the north of the base. The southernmost of these...grassy areas on base were limited to the three-toed box turtle (Terrapene carolina triunguis) and Fowler’s toad (Bufo woodhousei fowleri) (USAF 2002...known to other tribes as “Ugaxpa,” or “downstream people.” They settled four villages at the mouth of the Arkansas River where they remained until
1994-03-01
AND THE 7.X 4 C12’r RIGE PA SBOON PER NSONS OF BOX AND HAVINM BIYENSI1ON OF 17-AND2 LONG BY 11-1/2" WIDE BY 8-14’" HIOP, MRE SN)M. MAIMUM LADO WEIGHT O...INSTALL EACH STRAP FROM A TIEDOWN ANCHOR ON SIDE OF FATRACK, AROUND ENC OF PALLET AT EACH LOCATION SHOWN. TO A TI MWN ACHOR ON THE OPPOSITE SIDE OF
Zinc Bromide Flow Battery Installation for Islanding and Backup Power
2016-09-18
ability to control the generation has become more difficult with the increase of renewable energy systems such as solar photovoltaics ( PV ) and wind... PV and Inverter Room Building 6311 Rooftop Solar PV 30kW 232kW STC PV Array B5-PS2T33 Pad Switchboard ZnBr Energy Storage System (ESS) PowerBoxEnergy...Agreement • 1.5 MW of Photovoltaic • PV Parking lot lights • 24 Solar Thermal systems including the Combat Training Tank (Pool) Energy/Water Efficiency
Commander’s Guide to Public Involvement in the Army’s Installation, Restoration Program
1990-11-01
posed by chemicals at the local level and for dealing with emergencies within their communities. Industry is responsible for gathering information on the...helping set up procedures to handle chemical emergencies. At the federal level, EPA is responsible for ensuring that industry complies with the law’s...2816 Agana. GU 96910 011-671-734-2671 PUERTO RICO Environmental Quality Board 204 Del Parque Street Mail to: P.O. Box 11488 Santirce, PR 00910 (809) 725
Silica-Based Optical Time-Shift Network.
1996-03-01
consisted of semiconductor lasers and detectors, RF transfer -switches, low noise RF amplifiers (LNA), and T2L circuitries installed to enable switching...F/O TRANSFER BOX (1) RADIATING ELEMENTS 1:8 POWER DIVIDER (24 CARDS) 1.4 POWER DIVIDER (24) Tr/R MODULE (24) F/O DELAY WITH 2 TRANSFER SWITCHES AND 1...of the mode can travel is the velocity of light (= c/ni) in the outer clad, the part of it that lies beyond a critical radius Rc would not be able to
An Analysis Platform for Mobile Ad Hoc Network (MANET) Scenario Execution Log Data
2016-01-01
these technologies. 4.1 Backend Technologies • Java 1.8 • my-sql-connector- java -5.0.8.jar • Tomcat • VirtualBox • Kali MANET Virtual Machine 4.2...Frontend Technologies • LAMPP 4.3 Database • MySQL Server 5. Database The SEDAP database settings and structure are described in this section...contains all the backend java functionality including the web services, should be placed in the webapps directory inside the Tomcat installation
Skylight book. Capturing the Sun and the Moon: a guide to creating natural light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burns, A.
1976-01-01
The following topics are covered: planning; essential tools: hand and power; safety hints; curb installation; plexiglas or plate glass skylight; the plexiglas box skylight; tips on working with plexiglas; checking for leaks; framing the shaftway; electric work; shaftwall insulation; covering the shaftway with drywall; other kinds of wall coverings; internal storm windows; plants under your skylight; skylight manufacturers; and places to buy things. There are 38 pages of pictures of the use of skylights. (MHR)
Discovery Orbiter Major Modifications
2003-08-27
During power-up of the orbiter Discovery in the Orbiter Processing Facility, a technician moves a circuit reset on the cockpit console. Discovery has been undergoing Orbiter Major Modifications in the past year, ranging from wiring, control panels and black boxes to gaseous and fluid systems tubing and components. These systems were deserviced, disassembled, inspected, modified, reassembled, checked out and reserviced, as were most other systems onboard. The work includes the installation of the Multifunction Electronic Display Subsystem (MEDS) - a state-of-the-art “glass cockpit.”
A tele-home care system exploiting the DVB-T technology and MHP.
Angius, G; Pani, D; Raffo, L; Randaccio, P; Seruis, S
2008-01-01
The aim of this research work is the development of a low-cost system for telemedicine based on the DVB-T technology. The diffusion of DVB-T standard and the low cost of DVB-T set-top boxes bring the vision of a capillary distribution of tele-home care monitoring systems with easy-to-use patient's interface. Exploiting the potentiality of the DVB-T set-top box, we transformed it into an "on-demand tele-home care interface". The Xlet we developed is able to govern the functionality of an external microcontroller-based unit for the acquisition of the bio-signals of interest. The uplink connection is used to send the exam results to a remote care center. The Xlet providing the patient interface on the set-top box is uploaded by a DVB-T broadcaster without any intervention in the patient's home. A prototypal low-cost base station for the acquisition of the patient's signals (1-lead ECG) has been developed. It is able to be connected to the set-top box via an infrared link. A smart-card-based system is in charge for the customization of the Xlet for every patient. The proposed system, based on a currently widespread infrastructure, is able to allow the patients monitoring from home without any installation procedure. Even untrained (or elderly) people can easily use such system due to their practice with the basic DVB-T home-entertainment equipments.
NASA Astrophysics Data System (ADS)
Petersen, W.; Wehde, H.; Krasemann, H.; Colijn, F.; Schroeder, F.
2008-04-01
An automatic measuring system called " FerryBox" was installed in the North Sea on a ferry travelling between Germany (Cuxhaven) and Great Britain (Harwich), enabling online oceanographic and biological measurements such as salinity, temperature, fluorescence, turbidity, oxygen, pH, and nutrient concentrations. Observations made along the ferry transect reveal characteristic phenomena such as high salinity inflow through the Channel into the Southern Bight, algal bloom dynamics and related oxygen and pH changes. Combination of these online observations with remote sensing enhances the spatial resolution of the transect related measurements. Several examples of the synergy between these two measuring strategies are shown, both for large-scale algal blooms in the North Sea as well as for local intense but short-term blooms in the German Bight. Coherence of the data sets can be gained and improved by using water transport models in order to obtain synoptic overviews of the remotely sensed and FerryBox related parameters. Limitations of the currently used algorithms for deriving chlorophyll- a from remote sensing images for coastal and shelf seas (Case-2 water) are discussed, as well as depth related processes which cannot be properly resolved on the basis of water intake at a fixed point. However, in unstratified coastal waters under normal conditions FerryBox data represent average conditions. The importance of future applications of this combination of methods for monitoring of coastal waters is emphasized.
Validation and performance of the LHC cryogenic system through commissioning of the first sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serio, L.; Bouillot, A.; Casas-Cubillos, J.
2007-12-01
The cryogenic system [1] for the Large Hadron Collider accelerator is presently in its final phase of commissioning at nominal operating conditions. The refrigeration capacity for the LHC is produced using eight large cryogenic plants and eight 1.8 K refrigeration units installed on five cryogenic islands. Machine cryogenic equipment is installed in a 26.7-km circumference ring deep underground tunnel and are maintained at their nominal operating conditions via a distribution system consisting of transfer lines, cold interconnection boxes at each cryogenic island and a cryogenic distribution line. The functional analysis of the whole system during all operating conditions was establishedmore » and validated during the first sector commissioning in order to maximize the system availability. Analysis, operating modes, main failure scenarios, results and performance of the cryogenic system are presented.« less
Photovoltaic failure and degradation modes
Jordan, Dirk C.; Silverman, Timothy J.; Wohlgemuth, John H.; ...
2017-01-30
The extensive photovoltaic field reliability literature was analyzed and reviewed. Future work is prioritized based upon information assembled from recent installations, and inconsistencies in degradation mode identification are discussed to help guide future publication on this subject. Reported failure rates of photovoltaic modules fall mostly in the range of other consumer products; however, the long expected useful life of modules may not allow for direct comparison. In general, degradation percentages are reported to decrease appreciably in newer installations that are deployed after the year 2000. However, these trends may be convoluted with varying manufacturing and installation quality world-wide. Modules inmore » hot and humid climates show considerably higher degradation modes than those in desert and moderate climates, which warrants further investigation. Delamination and diode/j-box issues are also more frequent in hot and humid climates than in other climates. The highest concerns of systems installed in the last 10 years appear to be hot spots followed by internal circuitry discoloration. Encapsulant discoloration was the most common degradation mode, particularly in older systems. In newer systems, encapsulant discoloration appears in hotter climates, but to a lesser degree. Lastly, thin-film degradation modes are dominated by glass breakage and absorber corrosion, although the breadth of information for thin-film modules is much smaller than for x-Si.« less
Photovoltaic failure and degradation modes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jordan, Dirk C.; Silverman, Timothy J.; Wohlgemuth, John H.
The extensive photovoltaic field reliability literature was analyzed and reviewed. Future work is prioritized based upon information assembled from recent installations, and inconsistencies in degradation mode identification are discussed to help guide future publication on this subject. Reported failure rates of photovoltaic modules fall mostly in the range of other consumer products; however, the long expected useful life of modules may not allow for direct comparison. In general, degradation percentages are reported to decrease appreciably in newer installations that are deployed after the year 2000. However, these trends may be convoluted with varying manufacturing and installation quality world-wide. Modules inmore » hot and humid climates show considerably higher degradation modes than those in desert and moderate climates, which warrants further investigation. Delamination and diode/j-box issues are also more frequent in hot and humid climates than in other climates. The highest concerns of systems installed in the last 10 years appear to be hot spots followed by internal circuitry discoloration. Encapsulant discoloration was the most common degradation mode, particularly in older systems. In newer systems, encapsulant discoloration appears in hotter climates, but to a lesser degree. Lastly, thin-film degradation modes are dominated by glass breakage and absorber corrosion, although the breadth of information for thin-film modules is much smaller than for x-Si.« less
NASA Astrophysics Data System (ADS)
Delaney, J. R.; Kelley, D. S.; Proskurowski, G. K.; Kawka, O. E.; Fundis, A.; Mulvihill, M.; Harkins, G.; Harrington, M.; McGuire, C.; Manalang, D.; Light, R.; Stewart, A.; Brand, B.
2013-12-01
Since mid-year 2011, NSF's Ocean Observatories Initiative has made considerable progress in installing its cabled seafloor and water-column component off the Washington-Oregon Coast. The Primary Infrastructure is nearly operational and includes ~900 km of high-power (10 kV) and bandwidth (10 Gbs) submarine electro-optical cable and 7 seafloor power- and communications switching stations (nodes) in a two-cable network spanning tectonically active zones across the Juan de Fuca Plate, with access to the overlying ocean. The system is connected to a shore-landing in Pacific City, Oregon, with a dual-path terrestrial backhaul to Portland where connections to major continent-wide, high-speed networks link via the Internet to the undersea system. During summer 2013 the VISIONS'13 expedition, using the R/V Thompson and the remotely operated vehicle (ROV) ROPOS, placed a number of secondary infrastructure elements on the seafloor, ready to be connected to the Primary Nodes when the system is fully tested and accepted by the Consortium for Ocean Leadership. Secondary infrastructure installed using the ROV ROPOS includes over 23,000 meters of extension cables, which comprise twelve electro-optical and electrical cables that provide links from the Primary Nodes to experimental sites and instrument clusters. Smaller nodes (junction boxes) were also deployed, with three installed on the seafloor. All cables and junction boxes were fully tested, which included powering up and communicating through the nodes and sensors using the ROV ROPOS as a power-communication source, and live data transmission of the resultant engineering and science data to the ship located 3000-1500m above the seafloor. Locations include sites near the base of the continental slope and on Axial Seamount, the most magmatically active volcano on the Juan de Fuca Ridge. Real-time data streamed from instruments connected to extension cables at Axial Volcano via ROPOS revealed a significant local earthquake on the volcano, and a minor signal showing direct tidal measurements from 300 miles offshore. Sensors to be installed and connected in 2014 will provide seismic information, current velocities, inflation and deflation measurements of the volcanic caldera, high-definition video on demand, digital-still imagery, chemical data from methane seeps and vent sites using mass spectrometers, and an array of thermistors in a low-temperature vent field. Six instrumented full water-column moorings with two different types of profilers will be installed and connected to the cable in 2014.
NASA Technical Reports Server (NTRS)
Ko, William L.; Fleischer, Van Tran
2009-01-01
The Ko displacement theory previously formulated for deformed shape predictions of nonuniform beam structures is further developed mathematically. The further-developed displacement equations are expressed explicitly in terms of geometrical parameters of the beam and bending strains at equally spaced strain-sensing stations along the multiplexed fiber-optic sensor line installed on the bottom surface of the beam. The bending strain data can then be input into the displacement equations for calculations of local slopes, deflections, and cross-sectional twist angles for generating the overall deformed shapes of the nonuniform beam. The further-developed displacement theory can also be applied to the deformed shape predictions of nonuniform two-point supported beams, nonuniform panels, nonuniform aircraft wings and fuselages, and so forth. The high degree of accuracy of the further-developed displacement theory for nonuniform beams is validated by finite-element analysis of various nonuniform beam structures. Such structures include tapered tubular beams, depth-tapered unswept and swept wing boxes, width-tapered wing boxes, and double-tapered wing boxes, all under combined bending and torsional loads. The Ko displacement theory, combined with the fiber-optic strain-sensing system, provide a powerful tool for in-flight deformed shape monitoring of unmanned aerospace vehicles by ground-based pilots to maintain safe flights.
Servicing a globally broadcast interrupt signal in a multi-threaded computer
Attinella, John E.; Davis, Kristan D.; Musselman, Roy G.; Satterfield, David L.
2015-12-29
Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whether global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.
Wind Noise Reduction in a Non-Porous Subsurface Windscreen
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J.; Shams, Qamar A.; Knight, H. Keith
2012-01-01
Measurements of wind noise reduction were conducted on a box-shaped, subsurface windscreen made of closed cell polyurethane foam. The windscreen was installed in the ground with the lid flush with the ground surface. The wind was generated by means of a fan, situated on the ground, and the wind speed was measured at the center of the windscreen lid with an ultrasonic anemometer. The wind speed was controlled by moving the fan to selected distances from the windscreen. The wind noise was measured on a PCB Piezotronics 3†electret microphone. Wind noise spectra were measured with the microphone exposed directly to the wind (atop the windscreen lid) and with the microphone installed inside the windscreen. The difference between the two spectra comprises the wind noise reduction. At wind speeds of 3, 5, and 7 m/s, the wind noise reduction is typically 15 dB over the frequency range of 0.1-20 Hz.
Solar hot water system installed at Day's Lodge, Atlanta, Georgia
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1980-09-01
The solar energy hot water system installed in the Days Inns of America, Inc., Day's Lodge I-85 and Shallowford Road, NE Atlanta, Georgia is described. This system is one of eleven systems planned under this grant and was designed to provide for 81% of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drains whenever the collector plates approach freezing or when powermore » is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric domestic hot water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting. Operation of this system was begun in August, 1979. The solar components were partly funded ($18,042 of $36,084 cost) by the Department of Energy.« less
Fuel cells provide a revenue-generating solution to power quality problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, J.M. Jr.
Electric power quality and reliability are becoming increasingly important as computers and microprocessors assume a larger role in commercial, health care and industrial buildings and processes. At the same time, constraints on transmission and distribution of power from central stations are making local areas vulnerable to low voltage, load addition limitations, power quality and power reliability problems. Many customers currently utilize some form of premium power in the form of standby generators and/or UPS systems. These include customers where continuous power is required because of health and safety or security reasons (hospitals, nursing homes, places of public assembly, air trafficmore » control, military installations, telecommunications, etc.) These also include customers with industrial or commercial processes which can`t tolerance an interruption of power because of product loss or equipment damage. The paper discusses the use of the PC25 fuel cell power plant for backup and parallel power supplies for critical industrial applications. Several PC25 installations are described: the use of propane in a PC25; the use by rural cooperatives; and a demonstration of PC25 technology using landfill gas.« less
Multimodal Excitatory Interfaces with Automatic Content Classification
NASA Astrophysics Data System (ADS)
Williamson, John; Murray-Smith, Roderick
We describe a non-visual interface for displaying data on mobile devices, based around active exploration: devices are shaken, revealing the contents rattling around inside. This combines sample-based contact sonification with event playback vibrotactile feedback for a rich and compelling display which produces an illusion much like balls rattling inside a box. Motion is sensed from accelerometers, directly linking the motions of the user to the feedback they receive in a tightly closed loop. The resulting interface requires no visual attention and can be operated blindly with a single hand: it is reactive rather than disruptive. This interaction style is applied to the display of an SMS inbox. We use language models to extract salient features from text messages automatically. The output of this classification process controls the timbre and physical dynamics of the simulated objects. The interface gives a rapid semantic overview of the contents of an inbox, without compromising privacy or interrupting the user.
A 21st-century shift from fossil-fuel to biogenic methane emissions indicated by ¹³CH₄.
Schaefer, Hinrich; Mikaloff Fletcher, Sara E; Veidt, Cordelia; Lassey, Keith R; Brailsford, Gordon W; Bromley, Tony M; Dlugokencky, Edward J; Michel, Sylvia E; Miller, John B; Levin, Ingeborg; Lowe, Dave C; Martin, Ross J; Vaughn, Bruce H; White, James W C
2016-04-01
Between 1999 and 2006, a plateau interrupted the otherwise continuous increase of atmospheric methane concentration [CH4] since preindustrial times. Causes could be sink variability or a temporary reduction in industrial or climate-sensitive sources. We reconstructed the global history of [CH4] and its stable carbon isotopes from ice cores, archived air, and a global network of monitoring stations. A box-model analysis suggests that diminishing thermogenic emissions, probably from the fossil-fuel industry, and/or variations in the hydroxyl CH4 sink caused the [CH4] plateau. Thermogenic emissions did not resume to cause the renewed [CH4] rise after 2006, which contradicts emission inventories. Post-2006 source increases are predominantly biogenic, outside the Arctic, and arguably more consistent with agriculture than wetlands. If so, mitigating CH4 emissions must be balanced with the need for food production. Copyright © 2016, American Association for the Advancement of Science.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology. However, this technology is capable of bringing the air leakage of a building that was built with standard construction techniques and HERS-verified sealing down to levels that would meet DOE Zero Energy Ready Homes program requirements. When a developer is striving to meet a tighter envelope leakage specification, this technology could greatly reduce the cost to achieve that goal by providing a simple and relatively low cost method for reducing the air leakage of a building envelope with little to no change in their common building practices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Attinella, John E.; Davis, Kristan D.; Musselman, Roy G.
Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whethermore » global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.« less
Robust characterization of small grating boxes using rotating stage Mueller matrix polarimeter
NASA Astrophysics Data System (ADS)
Foldyna, M.; De Martino, A.; Licitra, C.; Foucher, J.
2010-03-01
In this paper we demonstrate the robustness of the Mueller matrix polarimetry used in multiple-azimuth configuration. We first demonstrate the efficiency of the method for the characterization of small pitch gratings filling 250 μm wide square boxes. We used a Mueller matrix polarimeter directly installed in the clean room has motorized rotating stage allowing the access to arbitrary conical grating configurations. The projected beam spot size could be reduced to 60x25 μm, but for the measurements reported here this size was 100x100 μm. The optimal values of parameters of a trapezoidal profile model, acquired for each azimuthal angle separately using a non-linear least-square minimization algorithm, are shown for a typical grating. Further statistical analysis of the azimuth-dependent dimensional parameters provided realistic estimates of the confidence interval giving direct information about the accuracy of the results. The mean values and the standard deviations were calculated for 21 different grating boxes featuring in total 399 measured spectra and fits. The results for all boxes are summarized in a table which compares the optical method to the 3D-AFM. The essential conclusion of our work is that the 3D-AFM values always fall into the confidence intervals provided by the optical method, which means that we have successfully estimated the accuracy of our results without using direct comparison with another, non-optical, method. Moreover, this approach may provide a way to improve the accuracy of grating profile modeling by minimizing the standard deviations evaluated from multiple-azimuths results.
NASA Astrophysics Data System (ADS)
Grüebler, Martin U.; Widmer, Silv; Korner-Nievergelt, Fränzi; Naef-Daenzer, Beat
2014-07-01
The microclimate of potential roost-sites is likely to be a crucial determinant in the optimal roost-site selection of endotherms, in particular during the winter season of temperate zones. Available roost-sites for birds and mammals in European high trunk orchards are mainly tree cavities, wood stacks and artificial nest boxes. However, little is known about the microclimatic patterns inside cavities and thermal advantages of using these winter roost-sites. Here, we simultaneously investigate the thermal patterns of winter roost-sites in relation to winter ambient temperature and their insulation capacity. While tree cavities and wood stacks strongly buffered the daily cycle of temperature changes, nest boxes showed low buffering capacity. The buffering effect of tree cavities was stronger at extreme ambient temperatures compared to temperatures around zero. Heat sources inside roosts amplified Δ T (i.e., the difference between inside and outside temperatures), particularly in the closed roosts of nest boxes and tree cavities, and less in the open wood stacks with stronger circulation of air. Positive Δ T due to the installation of a heat source increased in cold ambient temperatures. These results suggest that orchard habitats in winter show a spatiotemporal mosaic of sites providing different thermal benefits varying over time and in relation to ambient temperatures. At cold temperatures tree cavities provide significantly higher thermal benefits than nest boxes or wood stacks. Thus, in winter ecology of hole-using endotherms, the availability of tree cavities may be an important characteristic of winter habitat quality.
3D resistivity method to monitor degradation of an organic contaminant in sand boxes
NASA Astrophysics Data System (ADS)
Fernandez, P. M.; Bloem, E.; Philippe, R.; French, H. K.
2015-12-01
Degradation of organic chemicals under various saturation conditions is a process highly relevant to protect groundwater. The redox potential drives the degradation of organic compounds. Its variation affects the water chemistry, gas release and responses of the geo-electrical signature. This study explores how non-invasive measurements sensitive to geo-electrical properties provides quantitative information about the in-situ redox situation. During this presentation, the preliminary results of a laboratory experiment to study the degradation of deicing chemicals with 3D resistivity and self-potential techniques, water samples will be shown. The experiment consists of sand boxes (1.0x0.5x0.4 m) to which both sides of each box is contaminated with propylene glycol, an aircraft deicing fluid, commonly used in Norwegian airports. Each source is placed near the water table with static conditions. At one side a conductor is placed, linking the contamination zone at the water table and the unsaturated zone with a low water content, to improve the degradation by facilitating the electron exchange. At the other side, degradation occurs under natural conditions. Each box is equipped with 288 electrodes, distributed on six faces to perform 3D resistivity measurements. In addition to the resistivity, self-potential measurements are taken from the sand surface. Six water wells are installed above and below the water table to provide more information on the degradation processes. Moreover, measurements of carbon dioxide on the surface are performed as higher concentrations are expected where the pollutant is degraded.
1989-02-01
contrac: b. Stitt b) Oklahoma L a) Motor housings, junction and switch boxes, ocher a. Arvua o be Avoided electrical equipment I b. Azau to beTreated w...REPORT DOCUMENTATION PAGE ! ,a,,mo i.,e0q 8 1. AGENCY USE ONLY ’ L -ave aianK) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED l February 1989 Final...recommendations for further action. The subcontractor effort was conducted by the following Science & Technology, Inc. (SciTek) personnel: Mr. Tracy C. Brown
1985-08-09
and regulations. Additional hazard areas refer to non-regulated operations and/or practices that pose potential risks to human and environmental ...ORGANI1A’iON REPORT NUMPERASE IRP-IIa-AFP6 64 xAfi OF PEROING ORG IS ZArTON Śo 7a.AM OF MONITORING OAYIZAToN Environmental Science ’ aeedwabi.) U.S. Air...Force and Engineering, Inc ca ed AORESS Y. State, And ZIP C017) AOSS Approvetaoe pblic reease; P. Box ESE Occupational and Environmental Gainesville, FL
Executing application function calls in response to an interrupt
Almasi, Gheorghe; Archer, Charles J.; Giampapa, Mark E.; Gooding, Thomas M.; Heidelberger, Philip; Parker, Jeffrey J.
2010-05-11
Executing application function calls in response to an interrupt including creating a thread; receiving an interrupt having an interrupt type; determining whether a value of a semaphore represents that interrupts are disabled; if the value of the semaphore represents that interrupts are not disabled: calling, by the thread, one or more preconfigured functions in dependence upon the interrupt type of the interrupt; yielding the thread; and if the value of the semaphore represents that interrupts are disabled: setting the value of the semaphore to represent to a kernel that interrupts are hard-disabled; and hard-disabling interrupts at the kernel.
NASA Astrophysics Data System (ADS)
Azarov, A. V.; Zhukova, N. S.; Kozlovtseva, E. Yu; Dobrinsky, D. R.
2018-05-01
The article considers obtaining mathematical models to assess the efficiency of the dust collectors using an integrated system of analysis and data management STATISTICA Design of Experiments. The procedure for obtaining mathematical models and data processing is considered by the example of laboratory studies on a mounted installation containing a dust collector in counter-swirling flows (CSF) using gypsum dust of various fractions. Planning of experimental studies has been carried out in order to reduce the number of experiments and reduce the cost of experimental research. A second-order non-position plan (Box-Bencken plan) was used, which reduced the number of trials from 81 to 27. The order of statistical data research of Box-Benken plan using standard tools of integrated system for analysis and data management STATISTICA Design of Experiments is considered. Results of statistical data processing with significance estimation of coefficients and adequacy of mathematical models are presented.
NASA Technical Reports Server (NTRS)
Marze, H. J.; Dambra, F.
1978-01-01
Noise sources inside helicopter cabins are considered with emphasis on the mechanisms of vibration generation inside the main gear box and mechanisms of transmission between source and cabin. The dynamic behavior of the main gear box components is examined in relation to the transfer of vibration energy to the structure. It is indicated that although improvements can be made in noise reduction at the source, a soundproofing treatment isolating the passenger from the noise source is necessary. Soundproofing treatments installed and optimized include: (1) an acoustic screen using the weight effect to isolate the passenger from the noise source; (2) a damping treatment to limit the conversion of the vibratory energy into acoustic energy; and (3) an absorbing treatment achieved either through HELMHOLTZ resonators or through a glass wool blanket to limit the propagation of acoustic waves and the wave reflection effects in the cabin. The application of treatments at the source and the optimization of the sound barriers improved the noise level by about 30 db.
A Study of Light Level Effect on the Accuracy of Image Processing-based Tomato Grading
NASA Astrophysics Data System (ADS)
Prijatna, D.; Muhaemin, M.; Wulandari, R. P.; Herwanto, T.; Saukat, M.; Sugandi, W. K.
2018-05-01
Image processing method has been used in non-destructive tests of agricultural products. Compared to manual method, image processing method may produce more objective and consistent results. Image capturing box installed in currently used tomato grading machine (TEP-4) is equipped with four fluorescence lamps to illuminate the processed tomatoes. Since the performance of any lamp will decrease if its service time has exceeded its lifetime, it is predicted that this will affect tomato classification. The objective of this study was to determine the minimum light levels which affect classification accuracy. This study was conducted by varying light level from minimum and maximum on tomatoes in image capturing boxes and then investigates its effects on image characteristics. Research results showed that light intensity affects two variables which are important for classification, for example, area and color of captured image. Image processing program was able to determine correctly the weight and classification of tomatoes when light level was 30 lx to 140 lx.
Understanding Emergency Medicine Physicians Multitasking Behaviors Around Interruptions.
Fong, Allan; Ratwani, Raj M
2018-06-11
Interruptions can adversely impact human performance, particularly in fast-paced and high-risk environments such as the emergency department (ED). Understanding physician behaviors before, during, and after interruptions is important to the design and promotion of safe and effective workflow solutions. However, traditional human factors based interruption models do not accurately reflect the complexities of real-world environments like the ED and may not capture multiple interruptions and multitasking. We present a more comprehensive framework for understanding interruptions that is composed of three phases, each with multiple levels: Interruption Start Transition, Interruption Engagement, and Interruption End Transition. This three-phase framework is not constrained to discrete task transitions, providing a robust method to categorize multitasking behaviors around interruptions. We apply this framework in categorizing 457 interruption episodes. 457 interruption episodes were captured during 36 hours of observation. The interrupted task was immediately suspended 348 (76.1%) times. Participants engaged in new self-initiated tasks during the interrupting task 164 (35.9%) times and did not directly resume the interrupted task in 284 (62.1%) interruption episodes. Using this framework provides a more detailed description of the types of physician behaviors in complex environments. Understanding the different types of interruption and resumption patterns, which may have a different impact on performance, can support the design of interruption mitigation strategies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Assimilating Ferry Box data into the Aegean Sea model
NASA Astrophysics Data System (ADS)
Korres, G.; Ntoumas, M.; Potiris, M.; Petihakis, G.
2014-12-01
Operational monitoring and forecasting of marine environmental conditions is a necessary tool for the effective management and protection of the marine ecosystem. It requires the use of multi-variable real-time measurements combined with advanced physical and ecological numerical models. Towards this, a FerryBox system was originally installed and operated in the route Piraeus-Heraklion in 2003 for one year. Early 2012 the system was upgraded and moved to a new high-speed ferry traveling daily in the same route as before. This route is by large traversing the Cretan Sea being the largest and deepest basin (2500 m) in the south Aegean Sea. The HCMR Ferry Box is today the only one in the Mediterranean and thus it can be considered as a pilot case. The analysis of FerryBox SST and SSS in situ data revealed the presence of important regional and sub-basin scale physical phenomena, such as wind-driven coastal upwelling and the presence of a mesoscale cyclone to the north of Crete. In order to assess the impact of the FerryBox SST data in constraining the Aegean Sea hydrodynamic model which is part of the POSEIDON forecasting system, the in situ data were assimilated using an advanced multivariate assimilation scheme based on the Singular Evolutive Extended Kalman (SEEK) filter, a simplified square-root extended Kalman filter that operates with low-rank error covariance matrices as a way to reduce the computational burden. Thus during the period mid-August 2012-mid January 2013 in addition to the standard assimilating parameters, daily SST data along the ferryboat route from Piraeus to Heraklion were assimilated into the model. Inter-comparisons between the control run of the system (model run that uses only the standard data set of observations) and the experiment where the observational data set is augmented with the FerryBox SST data produce interesting results. Apart from the improvement of the SST error, the additional assimilation of daily of FerryBox SST observations is found to have a significant impact on the correct representation of the dynamical dipole in the central Cretan Sea and other dynamic features of the South Aegean Sea, which is then depicted in the decrease of the basin wide SSH RMS error.
Wireless modification of the intraoperative examination monitor for awake surgery.
Yoshimitsu, Kitaro; Maruyama, Takashi; Muragaki, Yoshihiro; Suzuki, Takashi; Saito, Taiichi; Nitta, Masayuki; Tanaka, Masahiko; Chernov, Mikhail; Tamura, Manabu; Ikuta, Soko; Okamoto, Jun; Okada, Yoshikazu; Iseki, Hiroshi
2011-01-01
The dedicated intraoperative examination monitor for awake surgery (IEMAS) was originally developed by us to facilitate the process of brain mapping during awake craniotomy and successfully used in 186 neurosurgical procedures. This information-sharing device provides the opportunity for all members of the surgical team to visualize a wide spectrum of the integrated intraoperative information related to the condition of the patient, nuances of the surgical procedure, and details of the cortical mapping, practically without interruption of the surgical manipulations. The wide set of both anatomical and functional parameters, such as view of the patient's mimic and face movements while answering the specific questions, type of the examination test, position of the surgical instruments, parameters of the bispectral index monitor, and general view of the surgical field through the operating microscope, is presented compactly in one screen with several displays. However, the initially designed IEMAS system was occasionally affected by interruption or detachment of the connecting cables, which sometimes interfered with its effective clinical use. Therefore, a new modification of the device was developed. The specific feature is installation of wireless information transmitting technology using audio-visual transmitters and receivers for transfer of images and verbal information. The modified IEMAS system is very convenient to use in the narrow space of the operating room.
Civionics specifications for fiber optic sensors for structural health monitoring
NASA Astrophysics Data System (ADS)
Rivera, Evangeline; Mufti, Aftab A.; Thomson, Douglas J.
2004-07-01
As the design and construction of civil structures continue to evolve, it is becoming imperative that these structures be monitored for their health. In order to meet this need, the discipline of Civionics has emerged. It involves the applications to civil structures and aims to assist engineers in realizing the full benefits of structural health monitoring (SHM). Therefore, the goal of the specification outlined in this work is to ensure that correct installation and operating of fiber optic sensors, such as bridges, will be discussed that motivated the writing of these specifications. The main reason for the failure of FOS based monitoring systems can be traced directly to the installation of the fiber sensor itself. Therefore, by creating a standard procedure for SHM, several ambiguities are eliminated such as fiber sensor specifications and the types of cables required. As a result, these specifications will help ensure that the sensors will survive the installation process and eventually prove their value over years of monitoring the health of the structure. The Civionics FOS specifications include the requirements for fiber sensors, specifically Bragg grating sensors, and their corresponding readout unit. It also includes specifications on the cables, conduits, junction boxes, cable termination and the environmental.
Measurements on Compressor-Blade Lattices
NASA Technical Reports Server (NTRS)
Weinig, F.
1948-01-01
At the end & 1940 an investigation of a guide-vane lattice for the compressor of a TL unit [NACA comment: Turbojet] was requested. The greatest possible Mach number had to be attained. The investigation was conducted with an annular lattice subjected to axial flow. A direct-current shunt motor with a useful output of 235 horsepower at en engine speed of 1800 qm was available for driving the necessary blower. In designing the blower the speed was set at 10,000 rpm. A gear box fran an armored car was used as gearing in which supplementary fresh oil lubrication was installed. The gear box was used to step up from low to high speeds. The blower that was designed is two stage. The hub-tip ratios are 0.79 to 0.82; the design pressure coefficient for each stage is 0.6 and the design flow coefficient is 0.4. The rotor dosimeter D sub a is 0.39 meters and the resulting peripheral speed is u sub a = 204 meters per second [NACA comment: Value corrected from the German]. The blower was entirely satisfactory. The construction of the test stand is shown in figure 1. The air flows in through an annular Inlet, which is used in the measurement of the quantity of air, and is deflected into an inward-pointing radial slot. A spiral motion is imparted to the air by a guide-vane installation manually adjustable as desired, which enables injection of the air, after it has been deflected from the radial direction to the axial direction, into the lattice being investigated at any desired angle.
Rivera, A Joy
2014-05-01
The purpose of this study was to understand the cognitive processes underlying nurses' decision to interrupt other nurses. The Institute of Medicine (2000) reported that interruptions are likely contributors to medical errors. Unfortunately, the research to date has been quite homogenous, focusing only on the healthcare provider being interrupted, ignoring the true complexities of interruptions. This study took a socio-technical approach being the first to examine interruptions from the viewpoint of the interrupting nurse. Over 15 h of observations and 10 open-ended interviews with expert nurses in a Neuroscience Surgical Intensive Care Unit were conducted. It was found that nurses conduct a quick cost-benefit assessment to determine the interruptibility of other nurses and whether an interruption is value-added vs. non-value added. To complete the assessment, nurses consider several conditional factors related to the interruptee, the interrupter, and the nature of the interruption content, and different potential consequences of the interruption. Published by Elsevier Ltd.
New Opportunities for Cabled Ocean Observatories
NASA Astrophysics Data System (ADS)
Duennebier, F. K.; Butler, R.; Karl, D. M.; Roger, L. B.
2002-12-01
With the decommissioning of transoceanic telecommunications cables as they become obsolete or uneconomical, there is an opportunity to use these systems for ocean observatories. Two coaxial cables, TPC-1 and HAW-2 are currently in use for observatories, and another, ANZCAN, is scheduled to be used beginning in 2004 to provide a cabled observatory at Station ALOHA, north of Oahu. The ALOHA observatory will provide several Mb/s data rates and about 1 kW of power to experiments installed at Station ALOHA. Sensors can be installed either by wet mateable connection to a junction box on the ocean floor using an ROV, or by acoustic data link to the system. In either case real-time data will be provided to users over the Internet. A Small Experiment Module, to be first installed at the Hawaii-2 Observatory, and later at Station ALOHA, will provide relatively cheap and uncomplicated access to the observatories for relatively simple sensors. Within the next few years, the first electro-optical cables installed in the 1980's will be decommissioned and could be available for scientific use. These cables could provide long "extension cords" (thousands of km) with very high bandwidth and reasonable power to several observatories in remote locations in the ocean. While they could be used in-place, a more exciting scenario is to use cable ships to pick up sections of cable and move them to locations of higher scientific interest. While such moves would not be cheap, the costs would rival the cost of installation and maintenance of a buoyed observatory, with far more bandwidth and power available for science use.
NASA Astrophysics Data System (ADS)
Mottershead, Derek N.; Stephenson, Wayne J.; Hemmingsen, Maree A.
2016-07-01
The sites of two field experiments based on micro-erosion metering, one in UK the other in New Zealand, were independently revisited respectively 33 and 17 years after installation. At both sites natural weathering and erosion processes had been inadvertently interrupted by the experimental works, leading to the development of new microscale landforms. These are interpreted in the context of modifications of the controls on weathering processes, leading to enhanced understanding of the processes themselves. This has lessons for the geomorphologist in maintaining a long-term watching brief over former experimental sites, lest some unintended and potentially beneficial outcome has ensued. This theme is embraced by the Law of Unintended Consequences.
An eye movement analysis of the effect of interruption modality on primary task resumption.
Ratwani, Raj; Trafton, J Gregory
2010-06-01
We examined the effect of interruption modality (visual or auditory) on primary task (visual) resumption to determine which modality was the least disruptive. Theories examining interruption modality have focused on specific periods of the interruption timeline. Preemption theory has focused on the switch from the primary task to the interrupting task. Multiple resource theory has focused on interrupting tasks that are to be performed concurrently with the primary task. Our focus was on examining how interruption modality influences task resumption.We leverage the memory-for-goals theory, which suggests that maintaining an associative link between environmental cues and the suspended primary task goal is important for resumption. Three interruption modality conditions were examined: auditory interruption with the primary task visible, auditory interruption with a blank screen occluding the primary task, and a visual interruption occluding the primary task. Reaction time and eye movement data were collected. The auditory condition with the primary task visible was the least disruptive. Eye movement data suggest that participants in this condition were actively maintaining an associative link between relevant environmental cues on the primary task interface and the suspended primary task goal during the interruption. These data suggest that maintaining cue association is the important factor for reducing the disruptiveness of interruptions, not interruption modality. Interruption-prone computing environments should be designed to allow for the user to have access to relevant primary task cues during an interruption to minimize disruptiveness.
Improving the effectiveness of an interruption lag by inducing a memory-based strategy.
Morgan, Phillip L; Patrick, John; Tiley, Leyanne
2013-01-01
The memory for goals model (Altmann & Trafton, 2002) posits the importance of a short delay (the 'interruption lag') before an interrupting task to encode suspended goals for retrieval post-interruption. Two experiments used the theory of soft constraints (Gray, Simms, Fu & Schoelles, 2006) to investigate whether the efficacy of an interruption lag could be improved by increasing goal-state access cost to induce a more memory-based encoding strategy. Both experiments used a copying task with three access cost conditions (Low, Medium, and High) and a 5-s interruption lag with a no lag control condition. Experiment 1 found that the participants in the High access cost condition resumed more interrupted trials and executed more actions correctly from memory when coupled with an interruption lag. Experiment 2 used a prospective memory test post-interruption and an eyetracker recorded gaze activity during the interruption lag. The participants in the High access cost condition with an interruption lag were best at encoding target information during the interruption lag, evidenced by higher scores on the prospective memory measure and more gaze activity on the goal-state during the interruption lag. Theoretical and practical issues regarding the use of goal-state access cost and an interruption lag are discussed. Copyright © 2012. Published by Elsevier B.V.
Do interruptions affect quality of work?
Foroughi, Cyrus K; Werner, Nicole E; Nelson, Erik T; Boehm-Davis, Deborah A
2014-11-01
The aim of this study was to determine if interruptions affect the quality of work. Interruptions are commonplace at home and in the office. Previous research in this area has traditionally involved time and errors as the primary measures of disruption. Little is known about the effect interruptions have on quality of work. Fifty-four students outlined and wrote three essays using a within-subjects design. During Condition 1, interruptions occurred while participants were outlining. During Condition 2, interruptions occurred while they were writing. No interruptions occurred in Condition 3. Quality of work was significantly reduced in both interruption conditions when compared to the non-interruption condition. The number of words produced was significantly reduced when participants were interrupted while writing the essay but not when outlining the essay. This research represents a crucial first step in understanding the effect interruptions have on quality of work. Our research suggests that interruptions negatively impact quality of work during a complex, creative writing task. Since interruptions are such a prevalent part of daily life, more research needs to be conducted to determine what other tasks are negatively impacted. Moreover, the underlying mechanism(s) causing these decrements needs to be identified. Finally, strategies and systems need to be designed and put in place to help counteract the decline in quality of work caused by interruptions.
1988-11-01
paint chips at the sampling site. 0 Clean water tanks, pumps, mud pans, hoses, including hoses and tanks used to transfer water from source to drill rig...TO’ LCA , Filll I F’APCr,;I~- € C/ " rKL2PIrlA , ATTFNrIGN TO SMOKING. ALCOHOLF MFDrICATIONP AND FXPOSI.RE TO CARCINOGENS.1 ENERAL MEDICAl. HISTORY...A. General: 1. Place samples in core trough for visual inspection. After logging, place selected samples in sample jars or wood core boxes. 2. Seal
International Space Station (ISS)
2007-06-11
STS-117 astronauts and mission specialists Jim Reilly (center frame), and John “Danny” Olivas (bottom center), participated in the first Extra Vehicular Activity (EVA) as construction resumed on the International Space Station (ISS). Among other tasks, the two connected power, data, and cooling cables between trusses 1 (S1) and 3 (S3), released the launch restraints from and deployed the four solar array blanket boxes on S4, and released the cinches and winches holding the photovoltaic radiator on S4. The primary mission objective was the installment of the second and third starboard truss segments (S3 and S4).
Investigating Interruptions: Implications for Flightdeck Performance
NASA Technical Reports Server (NTRS)
Latorella, Kara A.
1999-01-01
A fundamental aspect of multiple task management is attending to new stimuli and integrating associated task requirements into an ongoing task set; this is "interruption management" (IM). Anecdotal evidence and field studies indicate the frequency and consequences of interruptions, however experimental investigations of mechanisms influencing IM are scarce. Interruptions on commercial flightdecks are numerous, of various forms, and have been cited as contributing factors in many aviation incident and accident reports. This research grounds an experimental investigation of flightdeck interruptions in a proposed IM stage model. This model organizes basic research, identifies influencing mechanisms, and suggests appropriate dependent measures for IM. Fourteen airline pilots participated in a flightdeck simulation experiment to investigate the general effects of performing an interrupting task and interrupted procedure, and the effects of specific task factors: (1) modality; (2) embeddedness, or goal-level, of an interruption; (3) strength of association, or coupling-strength, between interrupted tasks; (4) semantic similarity; and (5) environmental stress. General effects of interruptions were extremely robust. All individual task factors significantly affected interruption management, except "similarity." Results extend the Interruption Management model, and are interpreted for their implications for interrupted flightdeck performance and intervention strategies for mitigating their effects on the flightdeck.
Flynn, Fran; Evanish, Julie Q; Fernald, Josephine M; Hutchinson, Dawn E; Lefaiver, Cheryl
2016-08-01
Because of the high frequency of interruptions during medication administration, the effectiveness of strategies to limit interruptions during medication administration has been evaluated in numerous quality improvement initiatives in an effort to reduce medication administration errors. To evaluate the effectiveness of evidence-based strategies to limit interruptions during scheduled, peak medication administration times in 3 progressive cardiac care units (PCCUs). A secondary aim of the project was to evaluate the impact of limiting interruptions on medication errors. The percentages of interruptions and medication errors before and after implementation of evidence-based strategies to limit interruptions were measured by using direct observations of nurses on 2 PCCUs. Nurses in a third PCCU served as a comparison group. Interruptions (P < .001) and medication errors (P = .02) decreased significantly in 1 PCCU after implementation of evidence-based strategies to limit interruptions. Avoidable interruptions decreased 83% in PCCU1 and 53% in PCCU2 after implementation of the evidence-based strategies. Implementation of evidence-based strategies to limit interruptions in PCCUs decreases avoidable interruptions and promotes patient safety. ©2016 American Association of Critical-Care Nurses.
Realization of the variant for management of AzT-2 telescope
NASA Astrophysics Data System (ADS)
Shavlovskyi, V. I.; Puha, S. P.; Vidmachenko, A. P.; Volovyk, D. V.; Puha, G. P.; Obolonskyi, V. O.; Kratko, O. O.; Stefurak, M. V.
2018-05-01
For the control system of the focus of the secondary mirror of the telescope AZT-2 we developed, manufactured and installed on the tube of the telescope a special shield for the addressable microcontroller. To manage its work with using a personal computer, a special control program was written. The tests of this system showed the ability to control the motor of focus unit both from the staff manual console and from the controller. To supply a stabilized voltage of 110 volts to the appropriate consumers, for a network of supplying control signals from a personal computer to the executive nodes via RS485 port, a series of distribution boxes were installed on the column and on the tube of the telescope. The developed software was also adapted to the algorithm of the existing manual system with manual operation. The control system of the telescope AZT-2 was tested in July-September 2017 at observations with the layout of filter polarimeter.
Cane, James E; Cauchard, Fabrice; Weger, Ulrich W
2012-01-01
Two experiments examined how interruptions impact reading and how interruption lags and the reader's spatial memory affect the recovery from such interruptions. Participants read paragraphs of text and were interrupted unpredictably by a spoken news story while their eye movements were monitored. Time made available for consolidation prior to responding to the interruption did not aid reading resumption. However, providing readers with a visual cue that indicated the interruption location did aid task resumption substantially in Experiment 2. Taken together, the findings show that the recovery from interruptions during reading draws on spatial memory resources and can be aided by processes that support spatial memory. Practical implications are discussed.
Interruption as a test of the user-computer interface
NASA Technical Reports Server (NTRS)
Kreifeldt, J. G.; Mccarthy, M. E.
1981-01-01
In order to study the effects different logic systems might have on interrupted operation, an algebraic calculator and a reverse polish notation calculator were compared when trained users were interrupted during problem entry. The RPN calculator showed markedly superior resistance to interruption effects compared to the AN calculator although no significant differences were found when the users were not interrupted. Causes and possible remedies for interruption effects are speculated. It is proposed that because interruption is such a common occurrence, it be incorporated into comparative evaluation tests of different logic system and control/display system and that interruption resistance be adopted as a specific design criteria for such design.
A food contaminant detection system based on high-Tc SQUIDs
NASA Astrophysics Data System (ADS)
Tanaka, Saburo; Fujita, H.; Hatsukade, Y.; Nagaishi, T.; Nishi, K.; Ota, H.; Otani, T.; Suzuki, S.
2006-05-01
We have designed and constructed a computer controlled food contaminant detection system for practical use, based on high-Tc SQUID detectors. The system, which features waterproof stainless steel construction, is acceptable under the HACCP (Hazard Analysis and Critical Control Point) programme guidelines. The outer dimensions of the system are 1500 mm length × 477 mm width × 1445 mm height, and it can accept objects up to 200 mm wide × 80 mm high. An automatic liquid nitrogen filling system was installed in the standard model. This system employed a double-layered permeable metallic shield with a thickness of 1 mm as a magnetically shielded box. The distribution of the magnetic field in the box was simulated by FEM; the gap between each shield layer was optimized before fabrication. A shielding factor of 732 in the Z-component was achieved. This value is high enough to safely operate the system in a non-laboratory environment, i.e., a factory. During testing, we successfully detected a steel contaminant as small as 0.3 mm in diameter at a distance of 75 mm.
A Safe Solution to Dopant Gas Desorption from Metal Surfaces
NASA Astrophysics Data System (ADS)
Nakanoya, Tsutomu; Egami, Maki
2006-11-01
TOXICAPTURE™ is used to further minimize trace toxic dopant gas inside cylinder valve outlets, which, over time, may desorb from metal surfaces. When outlet caps or connections to ion source gas cylinders are disconnected in order to perform installations or bottle changes, there always is some risk that toxic fumes resulting from desorption of the metal surface in contact with dopant gas are released in air and inhaled by the operator. TOXICAPTURE™ is a simple and easy solution to reduce this risk that may damage human health or may pollute clean room environment. TOXICAPTURE™ will react with the poison gas vapor to form nontoxic and solid material through irreversible chemical reactions. TOXICAPTURE™ prevents contamination and corrosion on gas contact surfaces of gas pipings, pressure regulators, pneumatic valves, mass flow controllers, and other parts in a gas box. TOXICAPTURE™ is highly effective in shortening the time to achieve high vacuum and in extending the lifetime of devices in the gas box. In this paper, we introduce the structure, functions, reactivity, applications, and effectivity of TOXICAPTURE™.
Control and protection of outdoor embedded camera for astronomy
NASA Astrophysics Data System (ADS)
Rigaud, F.; Jegouzo, I.; Gaudemard, J.; Vaubaillon, J.
2012-09-01
The purpose of CABERNET- Podet-Met (CAmera BEtter Resolution NETwork, Pole sur la Dynamique de l'Environnement Terrestre - Meteor) project is the automated observation, by triangulation with three cameras, of meteor showers to perform a calculation of meteoroids trajectory and velocity. The scientific goal is to search the parent body, comet or asteroid, for each observed meteor. To install outdoor cameras in order to perform astronomy measurements for several years with high reliability requires a very specific design for the box. For these cameras, this contribution shows how we fulfilled the various functions of their boxes, such as cooling of the CCD, heating to melt snow and ice, the protecting against moisture, lightning and Solar light. We present the principal and secondary functions, the product breakdown structure, the technical solutions evaluation grid of criteria, the adopted technology products and their implementation in multifunction subsets for miniaturization purpose. To manage this project, we aim to get the lowest manpower and development time for every part. In appendix, we present the measurements the image quality evolution during the CCD cooling, and some pictures of the prototype.
Minimum airflow reset of single-duct VAV terminal boxes
NASA Astrophysics Data System (ADS)
Cho, Young-Hum
Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.
SiMon: Simulation Monitor for Computational Astrophysics
NASA Astrophysics Data System (ADS)
Xuran Qian, Penny; Cai, Maxwell Xu; Portegies Zwart, Simon; Zhu, Ming
2017-09-01
Scientific discovery via numerical simulations is important in modern astrophysics. This relatively new branch of astrophysics has become possible due to the development of reliable numerical algorithms and the high performance of modern computing technologies. These enable the analysis of large collections of observational data and the acquisition of new data via simulations at unprecedented accuracy and resolution. Ideally, simulations run until they reach some pre-determined termination condition, but often other factors cause extensive numerical approaches to break down at an earlier stage. In those cases, processes tend to be interrupted due to unexpected events in the software or the hardware. In those cases, the scientist handles the interrupt manually, which is time-consuming and prone to errors. We present the Simulation Monitor (SiMon) to automatize the farming of large and extensive simulation processes. Our method is light-weight, it fully automates the entire workflow management, operates concurrently across multiple platforms and can be installed in user space. Inspired by the process of crop farming, we perceive each simulation as a crop in the field and running simulation becomes analogous to growing crops. With the development of SiMon we relax the technical aspects of simulation management. The initial package was developed for extensive parameter searchers in numerical simulations, but it turns out to work equally well for automating the computational processing and reduction of observational data reduction.
AIDE - Advanced Intrusion Detection Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Cathy L.
2013-04-28
Would you like to know when someone has dropped an undesirable executable binary on our system? What about something less malicious such as a software installation by a user? What about the user who decides to install a newer version of mod_perl or PHP on your web server without letting you know beforehand? Or even something as simple as when an undocumented config file change is made by another member of the admin group? Do you even want to know about all the changes that happen on a daily basis on your server? The purpose of an intrusion detection systemmore » (IDS) is to detect unauthorized, possibly malicious activity. The purpose of a host-based IDS, or file integrity checker, is check for unauthorized changes to key system files, binaries, libraries, and directories on the system. AIDE is an Open Source file and directory integrity checker. AIDE will let you know when a file or directory has been added, deleted, modified. It is included with the Red Hat Enterprise 6. It is available for other Linux distros. This is a case study describing the process of configuring AIDE on an out of the box RHEL6 installation. Its goal is to illustrate the thinking and the process by which a useful AIDE configuration is built.« less
Causes and occurrences of interruptions during ED triage.
Johnson, Kimberly D; Motavalli, Michele; Gray, Dean; Kuehn, Connie
2014-09-01
Interruptions have been shown to cause errors and delays in the treatment of emergency patients and pose a real threat during the triage process. Missteps during the triage assessment can send a patient down the wrong treatment path and lead to delays. The purpose of this project was to identify the types and frequency of interruptions during the ED triage interview process. A focus group of emergency nurses was organized to identify the types of interruptions that commonly occur during the triage interview. These interruptions would be validated through observations in triage. A tally sheet was developed and implemented to determine how often each interruption occurred during an 8-hour shift. Triage nurses completed the tally sheets while working the first shift (7 am to 3 pm). This shift was selected because patient intake in the US Department of Veterans Affairs Emergency Department is highest during this time. The categories of interruptions identified included provision of conveniences to visitors, coworker-related interruptions, patient care-related interruptions, locating of family members in the emergency department, and other miscellaneous interruptions. Tally sheets were completed by the triage nurses during 10 shifts. On average, triage nurses were interrupted 48.2 times during an 8-hour shift (7 interruptions per hour). After reviewing the data, we found that only 22% of interruptions were related to patient care. More frequently, the causes of interruptions were not related to patient care: opening the door (33%), providing conveniences to visitors (21%), waiting patients or family members asking "How much longer?" (14%), and other causes (10%). Frequent interruptions can interfere with concentration and may affect patient care. Non-patient care-related interruptions not only can be frustrating to the triage nurse but also can be offensive to triage patients; they ultimately delay care and may even affect the quality of care. However, because scarce research is available regarding interruptions during ED triage, the effects on patient outcomes are unclear. Additional research needs to be conducted to explore the causes and effects of interruptions to the triage process. Copyright © 2014 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.
Evaluation and Impact of Workflow Interruptions During Robot-assisted Surgery.
Allers, Jenna C; Hussein, Ahmed A; Ahmad, Nabeeha; Cavuoto, Lora; Wing, Joseph F; Hayes, Robin M; Hinata, Nobuyuki; Bisantz, Ann M; Guru, Khurshid A
2016-06-01
To analyze and categorize causes for interruptions during robot-assisted surgery. We analyzed 10 robot-assisted prostatectomies that were performed by 3 surgeons from October 2014 to June 2015. Interruptions to surgery were defined in terms of duration, stage of surgery, personnel involved, reasons, and impact of the interruption on the surgical workflow. The main reasons for interruptions included the following: console surgeons switching (29%); preparation of the surgical equipment, such as cleaning or changing the camera (29%) or an instrument (27%); or when a suture, stapler, or clip was needed (12%). The most common interruption duration was 10-29 seconds (47.6%), and the least common interruption duration was greater than 90 seconds (3.6%). Additionally, about 14% of the interruptions were considered avoidable, whereas the remaining 86% of interruptions were necessary for surgery. By identifying and analyzing interruptions, we can develop evidence-based strategies to improve operating room efficiency, lower costs, and advance patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.
Assessment of teacher interruptions on learners during oral case presentations.
Yang, Glen; Chin, Rachel
2007-06-01
Studies have only recently begun to investigate the effects of interruptions on physicians in the emergency department (ED). To determine the frequency and nature of interruptions by the training physician that occur when medical trainees do oral case presentations (OCPs) in the ED. This was an observational study. Learner OCPs to attending emergency physicians were observed in the ED of an urban Level 1 trauma center at a major teaching hospital. A single investigator followed attending physicians blinded to the study objective in a nonrandomized convenience sampling of all ED shifts, recording information regarding teacher interruptions during new patient presentations. Learners completed a brief questionnaire after each OCP. A total of 196 OCPs were observed. The mean (+/-SD) duration of OCPs was 3.30 (+/-1.85) minutes, and the mean (+/-SD) number of interruptions was 0.75 (+/-0.60) per minute and 2.49 (+/-1.95) per OCP. The number of interruptions (per OCP) and duration of OCP varied by learner level of training, with more experienced learners giving shorter presentations and being interrupted less often. Frequency (per minute) of interruptions did not vary by learner level. In 40.3% of OCPs, attending physicians interrupted to give an assessment and/or a plan before the learner had done so, but 8.3% of interrupted learners believed that teacher interruptions were "disruptive" to their OCP. Attending emergency physicians frequently interrupt learners during new patient OCPs, with the number of interruptions varying by learner level of training. Teacher interruptions appear to have minimal, if any, detrimental effect on the perceived effectiveness of OCPs as a learning experience.
Testing Of Choiced Ceramics Cutting Tools At Irregular Interrupted Cut
NASA Astrophysics Data System (ADS)
Kyncl, Ladislav; Malotová, Šárka; Nováček, Pavel; Nicielnik, Henryk; Šoková, Dagmar; Hemžský, Pavel; Pitela, David; Holubjak, Jozef
2015-12-01
This article discusses the test of removable ceramic cutting inserts during machining irregular interrupted cut. Tests were performed on a lathe, with the preparation which simulated us the interrupted cut. By changing the number of plates mounted in a preparation it simulate us a regular or irregular interrupted cut. When with four plates it was regular interrupted cut, the remaining three variants were already irregular cut. It was examined whether it will have the irregular interrupted cutting effect on the insert and possibly how it will change life of inserts during irregular interrupted cut (variable delay between shocks).
A Sensor-Based Method for Diagnostics of Machine Tool Linear Axes.
Vogl, Gregory W; Weiss, Brian A; Donmez, M Alkan
2015-01-01
A linear axis is a vital subsystem of machine tools, which are vital systems within many manufacturing operations. When installed and operating within a manufacturing facility, a machine tool needs to stay in good condition for parts production. All machine tools degrade during operations, yet knowledge of that degradation is illusive; specifically, accurately detecting degradation of linear axes is a manual and time-consuming process. Thus, manufacturers need automated and efficient methods to diagnose the condition of their machine tool linear axes without disruptions to production. The Prognostics and Health Management for Smart Manufacturing Systems (PHM4SMS) project at the National Institute of Standards and Technology (NIST) developed a sensor-based method to quickly estimate the performance degradation of linear axes. The multi-sensor-based method uses data collected from a 'sensor box' to identify changes in linear and angular errors due to axis degradation; the sensor box contains inclinometers, accelerometers, and rate gyroscopes to capture this data. The sensors are expected to be cost effective with respect to savings in production losses and scrapped parts for a machine tool. Numerical simulations, based on sensor bandwidth and noise specifications, show that changes in straightness and angular errors could be known with acceptable test uncertainty ratios. If a sensor box resides on a machine tool and data is collected periodically, then the degradation of the linear axes can be determined and used for diagnostics and prognostics to help optimize maintenance, production schedules, and ultimately part quality.
NASA Astrophysics Data System (ADS)
Shinkai, Takeshi; Koshiduka, Tadashi; Mori, Tadashi; Uchii, Toshiyuki; Tanaka, Tsutomu; Ikeda, Hisatoshi
Current zero measurements are performed for 245kV-50kA-60Hz short line fault (L90) interruption tests with a self-blast interrupting chamber (double volume system) which has the interrupting capability up to 245kV-50kA-50Hz L90. Lower L90 interruption capability is observed for longer arcing time although very high pressure rise is obtained. It may be caused by higher blowing temperature and lower blowing density for longer arcing time. Interruption criteria and a optimization method of the chamber design are discussed to improve L90 interruption capability with it. The new chambers are designed at 245kV-50kA-60Hz to improve gas density in thermal volume for long arcing time. 245kV-50kA-60Hz L90 interruptions are performed with the new chamber. The suggested optimization method is an efficient tool for the self-blast interrupting chamber design although study of computing methods is required to calculate arc conductance around current zero as a direct criterion for L90 interruption capability with higher accuracy.
Mamykina, Lena; Carter, Eileen J; Sheehan, Barbara; Stanley Hum, R; Twohig, Bridget C; Kaufman, David R
2017-05-01
To examine the apparent purpose of interruptions in a Pediatric Intensive Care Unit and opportunities to reduce their burden with informatics solutions. In this prospective observational study, researchers shadowed clinicians in the unit for one hour at a time, recording all interruptions participating clinicians experienced or initiated, their starting time, duration, and a short description that could help to infer their apparent purpose. All captured interruptions were classified inductively on their source and apparent purpose and on the optimal representational media for fulfilling their apparent purpose. The researchers observed thirty-four one-hour sessions with clinicians in the unit, including 21 nurses and 13 residents and house physicians. The physicians were interrupted on average 11.9 times per hour and interrupted others 8.8 times per hour. Nurses were interrupted 8.6 times per hour and interrupted others 5.1 times per hour. The apparent purpose of interruptions included Information Seeking and Sharing (n=259, 46.3%), Directives and Requests (n=70, 12%), Shared Decision-Making (n=49, 8.8%), Direct Patient Care (n=36, 6.4%), Social (n=71, 12.7%), Device Alarms (n=28, 5%), and Non-Clinical (n=10, 1.8%); 6.6% were not classified due to insufficient description. Of all captured interruptions, 29.5% were classified as being better served with informational displays or computer-mediated communication. Deeper understanding of the purpose of interruptions in critical care can help to distinguish between interruptions that require face-to-face conversation and those that can be eliminated with informatics solutions. The proposed taxonomy of interruptions and representational analysis can be used to further advance the science of interruptions in clinical care. Copyright © 2017 Elsevier Inc. All rights reserved.
Coping with interruptions in clinical nursing-A qualitative study.
Laustsen, Sussie; Brahe, Liselotte
2018-04-01
To gain knowledge on how nurses' cope with interruptions in clinical practice. Interruptions may delay work routines and result in wasted time, disorganised planning and ineffective working procedures, affecting nurses' focus and overview in different ways. Research has identified a growing problem linking errors or adverse events with interruptions. It may affect patient safety if nurses are not paying attention to interruptions. Little is known about how nurses cope with interruptions DESIGN: The study was inspired by ethnographic fieldwork with a hermeneutical phenomenological approach. Observations were performed combined with semi-structured qualitative interviews. Managing interruptions depend on level of competence, working environment, dialogue and matching of expectations, collegial roles and implicit rules. Working procedures impact on how nurses are exposed to unnecessary interruptions. The latter affects overview and the ability to put the foot down and decline being interrupted. Professional competencies for example prioritising, keeping focus and collaborating across disciplines are needed to cope with interruptions. Culture work and matching of expectations are important to reflect on and discuss personal- and group behaviour caused by interruptions. We need to focus on the role of each nurse in the professional team, types of personality and unspoken rules. Professional competencies for example prioritising, keeping focus and cooperating across disciplines are needed to cope with interruptions. Coping with interruptions is important for the nursing profession, quality of care and patient safety. Changing practice requires multidisciplinary cooperation accepting different agendas at personal, group and organisational levels. Nurses must understand the meaning and nature of different types of interruptions to develop coping strategies and maintain quality in care and patient safety in multidisciplinary teamwork. © 2018 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Cheng, Xian; Duan, Xiongying; Liao, Minfu; Huang, Zhihui; Luo, Yan; Zou, Jiyan
2013-08-01
Hybrid circuit breaker (HCB) technology based on a vacuum interrupter and a SF6 interrupter in series has become a new research direction because of the low-carbon requirements for high voltage switches. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage (TRV), while the SF6 interrupter can withstand the peak part of the voltage easily. An HCB can take advantage of the interrupters in the current interruption process. In this study, an HCB model based on the vacuum ion diffusion equations, ion density equation, and modified Cassie-Mayr arc equation is explored. A simulation platform is constructed by using a set of software called the alternative transient program (ATP). An HCB prototype is also designed, and the short circuit current is interrupted by the HCB under different action sequences of contacts. The voltage distribution of the HCB is analyzed through simulations and tests. The results demonstrate that if the vacuum interrupter withstands the initial TRV and interrupts the post-arc current first, then the recovery speed of the dielectric strength of the SF6 interrupter will be fast. The voltage distribution between two interrupters is determined by their post-arc resistance, which happens after current-zero, and subsequently, it is determined by the capacitive impedance after the post-arc current decays to zero.
The Effect of Interruption Duration and Demand on Resuming Suspended Goals
ERIC Educational Resources Information Center
Monk, Christopher A.; Trafton, J. Gregory; Boehm-Davis, Deborah A.
2008-01-01
The time to resume task goals after an interruption varied depending on the duration and cognitive demand of interruptions, as predicted by the memory for goals model (Altmann & Trafton, 2002). Three experiments using an interleaved tasks interruption paradigm showed that longer and more demanding interruptions led to longer resumption times in a…
2010-11-01
CAPE CANAVERAL, Fla. -- In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, the Alpha Magnetic Spectrometer-2 (AMS) will be rotated 180 degrees to provide better access for work to be performed on its avionics box. Technicians also will install a flight releasable grappling fixture to AMS while it is upside down. AMS is designed to operate as an external experiment on the International Space Station. It will use the unique environment of space to study the universe and its origin by searching for dark matter. AMS will fly to the station aboard space shuttle Endeavour's STS-134 mission targeted to launch Feb. 27, 2011. Photo credit: NASA/Jack Pfaller
2010-11-01
CAPE CANAVERAL, Fla. -- In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, the Alpha Magnetic Spectrometer-2 (AMS) will be rotated 180 degrees to provide better access for work to be performed on its avionics box. Technicians also will install a flight releasable grappling fixture to AMS while it is upside down. AMS is designed to operate as an external experiment on the International Space Station. It will use the unique environment of space to study the universe and its origin by searching for dark matter. AMS will fly to the station aboard space shuttle Endeavour's STS-134 mission targeted to launch Feb. 27, 2011. Photo credit: NASA/Jack Pfaller
2010-11-01
CAPE CANAVERAL, Fla. -- In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, the Alpha Magnetic Spectrometer-2 (AMS) rotates 180 degrees to provide better access for work to be performed on its avionics box. Technicians also will install a flight releasable grappling fixture to AMS while it is upside down. AMS is designed to operate as an external experiment on the International Space Station. It will use the unique environment of space to study the universe and its origin by searching for dark matter. AMS will fly to the station aboard space shuttle Endeavour's STS-134 mission targeted to launch Feb. 27, 2011. Photo credit: NASA/Jack Pfaller
2010-11-01
CAPE CANAVERAL, Fla. -- In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, the Alpha Magnetic Spectrometer-2 (AMS) is positioned at a 180-degree angle to provide better access for work to be performed on its avionics box. Technicians also will install a flight releasable grappling fixture to AMS while it is upside down. AMS is designed to operate as an external experiment on the International Space Station. It will use the unique environment of space to study the universe and its origin by searching for dark matter. AMS will fly to the station aboard space shuttle Endeavour's STS-134 mission targeted to launch Feb. 27, 2011. Photo credit: NASA/Jack Pfaller
2010-11-01
CAPE CANAVERAL, Fla. -- In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, the Alpha Magnetic Spectrometer-2 (AMS) rotates 180 degrees to provide better access for work to be performed on its avionics box. Technicians also will install a flight releasable grappling fixture to AMS while it is upside down. AMS is designed to operate as an external experiment on the International Space Station. It will use the unique environment of space to study the universe and its origin by searching for dark matter. AMS will fly to the station aboard space shuttle Endeavour's STS-134 mission targeted to launch Feb. 27, 2011. Photo credit: NASA/Jack Pfaller
Standard Engineering Installation Package, Standard Remote Terminals (SRT).
1981-10-30
6L L o 0 100 BOLT // M 0 (NOTE 3) N o @ 12 P o 13 NOTE: USE MiTN SAAD-D-4053 AND 0 14 • STD-SD-00SS DWS. 1I USE 3(4 CONDUIT AND BOX CONN. PUNCH OUT 3/4...TERMINAL STRIP. USE # BOLT TO MOUNT CONNECTOR TO DLII. USE OG STD-SO-007 FOR TERMINAL STRIP TERMINA- TION TO 153 PATCH PANEL. *1 f DUS1 is not or’dered... BOLTED TO FLOOR AS PER DUG 3I ®STu-SD-OO69 PROVIDING THERE IS INO CROSS OVLR WITH POWER AND SIGNAL CABLES. CROSSOVER WILL BE SEPERATED BY 4" MINIMUM
The acoustic design of the Centro Nacional de las Artes in Mexico City
NASA Astrophysics Data System (ADS)
Cooper, Rusell
2002-11-01
In this paper the acoustic design of the separate buildings housing the school of music, school of drama, and school of dance that opened in 1996 will be described. Spaces that JHA designed included practice rooms, studios, rehearsal rooms, black box, and concert hall. Details of room acoustic treatments, sound isolation measures, and venturi air flow will be illustrated. An overview of the entire project will also include the 500 seat multipurpose theater (with variable absorption systems) and the Alla Magna. Differences between the American and Mexican styles of consulting, importing of materials, installation, and commissioning will also be discussed.
Engaging spaces: Intimate electro-acoustic display in alternative performance venues
NASA Astrophysics Data System (ADS)
Bahn, Curtis; Moore, Stephan
2004-05-01
In past presentations to the ASA, we have described the design and construction of four generations of unique spherical speakers (multichannel, outward-radiating geodesic speaker arrays) and Sensor-Speaker-Arrays, (SenSAs: combinations of various sensor devices with outward-radiating multichannel speaker arrays). This presentation will detail the ways in which arrays of these speakers have been employed in alternative performance venues-providing presence and intimacy in the performance of electro-acoustic chamber music and sound installation, while engaging natural and unique acoustical qualities of various locations. We will present documentation of the use of multichannel sonic diffusion arrays in small clubs, ``black-box'' theaters, planetariums, and art galleries.
Opioid interruptions, pain, and withdrawal symptoms in nursing home residents.
Redding, Sarah E; Liu, Sophia; Hung, William W; Boockvar, Kenneth S
2014-11-01
Interruptions in opioid use have the potential to cause pain relapse and withdrawal symptoms. The objectives of this study were to observe patterns of opioid interruption during acute illness in nursing home residents and examine associations between interruptions and pain and withdrawal symptoms. Patients from 3 nursing homes in a metropolitan area who were prescribed opioids were assessed for symptoms of pain and withdrawal by researchers blinded to opioid dosage received, using the Brief Pain Inventory Scale and the Clinical Opioid Withdrawal Scale, respectively, during prespecified time periods. The prespecified time periods were 2 weeks after onset of acute illness (eg, urinary tract infection), and 2 weeks after hospital admission and nursing home readmission, if they occurred. Opioid dosing was recorded and a significant interruption was defined as a complete discontinuation or a reduction in dose of >50% for ≥1 day. The covariates age, sex, race, comorbid conditions, initial opioid dose, and initial pain level were recorded. Symptoms pre- and post-opioid interruptions were compared and contrasted with those in a group without opioid interruptions. Sixty-six patients receiving opioids were followed for a mean of 10.9 months and experienced a total of 104 acute illnesses. During 64 (62%) illnesses, patients experienced any reduction in opioid dosing, with a mean (SD) dose reduction of 63.9% (29.9%). During 39 (38%) illnesses, patients experienced a significant opioid interruption. In a multivariable model, residence at 1 of the 3 nursing homes was associated with a lower risk of interruption (odds ratio = 0.073; 95% CI, 0.009 to 0.597; P < 0.015). In patients with interruptions, there were statistically insignificant changes in mean (SD) pain score (difference -0.50 [2.66]; 95% CI, -3.16 to 2.16) and withdrawal score (difference -0.91 [3.12]; 95% CI, -4.03 to 2.21) after the interruption as compared with before interruption. However, when compared with patients without interruptions, patients with interruptions experienced larger increases in pain scores during the follow-up periods (difference 0.09 points per day; 95% CI, -0.01 to 0.019; P = 0.08). In particular, patients who received the highest quartile of opioid dose before interruption experienced increases in pain scores over time that were 0.22 points per day larger (95% CI, 0.02 to 0.41; P = 0.03) than those without interruption. Withdrawal scores were not associated with opioid interruption regardless of dose before interruption. Nursing home patients often experience interruptions in opioid dosing, which can be associated with worse pain, but not withdrawal symptoms, during acute illnesses. Clinicians should be aware of the potential risks and effects of opioid interruptions during acute illnesses in this patient group. Published by Elsevier Inc.
Lu, Sara A; Wickens, Christopher D; Prinet, Julie C; Hutchins, Shaun D; Sarter, Nadine; Sebok, Angelia
2013-08-01
The aim of this study was to integrate empirical data showing the effects of interrupting task modality on the performance of an ongoing visual-manual task and the interrupting task itself. The goal is to support interruption management and the design of multimodal interfaces. Multimodal interfaces have been proposed as a promising means to support interruption management.To ensure the effectiveness of this approach, their design needs to be based on an analysis of empirical data concerning the effectiveness of individual and redundant channels of information presentation. Three meta-analyses were conducted to contrast performance on an ongoing visual task and interrupting tasks as a function of interrupting task modality (auditory vs. tactile, auditory vs. visual, and single modality vs. redundant auditory-visual). In total, 68 studies were included and six moderator variables were considered. The main findings from the meta-analyses are that response times are faster for tactile interrupting tasks in case of low-urgency messages.Accuracy is higher with tactile interrupting tasks for low-complexity signals but higher with auditory interrupting tasks for high-complexity signals. Redundant auditory-visual combinations are preferable for communication tasks during high workload and with a small visual angle of separation. The three meta-analyses contribute to the knowledge base in multimodal information processing and design. They highlight the importance of moderator variables in predicting the effects of interruption task modality on ongoing and interrupting task performance. The findings from this research will help inform the design of multimodal interfaces in data-rich, event-driven domains.
Minimizing blood loss at cesarean-hysterectomy for placenta previa percreta.
Belfort, Michael A; Shamshiraz, Alireza A; Fox, Karin
2017-01-01
Preventing blood loss at the time of a cesarean delivery during a scheduled, nonemergent cesarean hysterectomy for placenta percreta may reduce the need for crystalloid and blood product transfusion. Commonly a classical hysterotomy is created and this can result in as much as a 500-800 mL blood loss before the hysterotomy is closed. Our technique involves placement of 4 full-thickness interrupted sutures in a box pattern to create an unperfused area of upper uterine segment. Diathermy is used to open the uterus to the membranes in the center of the "box" without blood loss. A finger is then inserted between the membranes and uterus to create a space into which 1 side of an 80-mm linear cutting stapler is introduced. The other side of the stapler is then attached and clamped closed, and the stapler is activated. Forward motion of the lever lays down 2 rows of staples, and backward movement of the lever divides the uterine muscle between the 2 staple lines. The stapler is removed and reloaded and reintroduced 1 or 2 times as needed to create an avascular hysterotomy large enough to atraumatically deliver the baby. The membranes are then opened and the baby is delivered. Following this the umbilical cord is clamped and cut without any attempt to remove the placenta, replaced in the uterine cavity, and the hysterotomy is closed with a running locked suture that incorporates the membrane edges. The hysterectomy then proceeds. In most cases there is minimal blood loss (usually <20 mL) from the cesarean delivery. Copyright © 2016 Elsevier Inc. All rights reserved.
Buchini, Sara; Quattrin, Rosanna
2012-04-01
To record the frequency of interruptions and their causes, to identify 'avoidable' interruptions and to build an improvement project to reduce 'avoidable' interruptions. In Italy each year 30,000-35,000 deaths per year are attributed to health-care system errors, of which 19% are caused by medication errors. The factors that contribute to drug management error also include interruptions and carelessness during treatment administration. A descriptive study design was used to record the frequency of interruptions and their causes and to identify 'avoidable' interruptions in an intensive rehabilitation ward in Northern Italy. A data collection grid was used to record the data over a 6-month period. A total of 3000 work hours were observed. During the study period 1170 interruptions were observed. The study identified 14 causes of interruption. The study shows that of the 14 cases of interruptions at least nine can be defined as 'avoidable'. An improvement project has been proposed to reduce unnecessary interruptions and distractions to avoid making errors. An additional useful step to reduce the incidence of treatment errors would be to implement the use of a single patient medication sheet for the recording of drug prescription, preparation and administration and also the incident reporting. © 2011 Blackwell Publishing Ltd.
Dealing with task interruptions in complex dynamic environments: are two heads better than one?
Tremblay, Sébastien; Vachon, François; Lafond, Daniel; Kramer, Chelsea
2012-02-01
This study examined whether teaming up mitigates individual vulnerability to task interruptions in complex dynamic situations. Omnipresent in everyday multitasking environments, task interruptions are usually detrimental to individual performance. This is particularly crucial in dynamic command and control (C2) safety-critical contexts because of the additional challenge imposed by the continually evolving situation during the interruption. We employed a firefighting microworld to simulate C2 in the context of supervisory control to examine the relative impact of interruptions on participants working in a functional dyad versus operators working alone. Although task interruption was detrimental to participants' efficacy of monitoring resources, the negative impact of interruption was reduced for those working in teams. Teaming up translated into faster resumption time, but only if both teammates were interrupted simultaneously. Interrupting only one team member was associated with increased postinterruption communications and slower resumption time. These findings suggest that in complex dynamic situations working in a small team confers more resistance to task interruption than working alone by virtue of the reduced individual workload typical of teamwork. The benefit of collaborative work seems nevertheless mediated by the coordination and communication overhead associated with teamwork. The present findings have practical implications for operators dealing with unexpected events such as task interruptions in C2 environments.
Vaisman, Alon; Wu, Robert C
2017-01-04
Hospital-based medical services are increasingly utilizing team-based pagers and smartphones to streamline communications. However, an unintended consequence may be higher volumes of interruptions potentially leading to medical error. There is likely a level at which interruptions are excessive and cause a 'crisis mode' climate. We retrospectively collected phone, text messaging, and email interruptions directed to hospital-assigned smartphones on eight General Internal Medicine (GIM) teams at two tertiary care centres in Toronto, Ontario from April 2013 to September 2014. We also calculated the number of times these interruptions exceeded a pre-specified threshold per hour, termed 'crisis mode', defined as at least five interruptions in 30 minutes. We analyzed the correlation between interruptions and date, site, and patient volumes. A total of 187,049 interruptions were collected over an 18-month period. Daily weekday interruptions rose sharply in the morning, peaking between 11 AM to 12 PM and measuring 4.8 and 3.7 mean interruptions/hour at each site, respectively. Mean daily interruptions per team totaled 46.2 ± 3.6 at Site 1 and 39.2 ± 4.2 at Site 2. The 'crisis mode' threshold was exceeded, on average, 2.3 times/day per GIM team during weekdays. In a multivariable linear regression analysis, site (β6.43 CI95% 5.44 - 7.42, p<0.001), day of the week (with Friday having the most interruptions) (β0.481 CI95% 0.236 - 0.730, p<0.05) and patient census (β1.55 CI95% 1.42 - 1.67, p<0.05) were all predictive of daily interruption volume although there was a significant interaction effect between site and patient census (β-0.941 CI95% -1.18 - -0.703, p<0.05). Interruptions were related to site-specific features, including volume, suggesting that future interventions should target the culture of individual hospitals. Excessive interruptions may have implications for patient safety especially when exceeding a maximal threshold over short periods of time.
High-Gain Airborne Microphone Windscreen Characterization Method Using Modified Research Wind Tunnel
NASA Astrophysics Data System (ADS)
Banks, Joseph Andrew
In recent years, UAS (unmanned aerial systems) have gained improved functionality by integrating advanced cameras, sensors, and hardware systems; however, UAS still lack effective means to detect and record audio signals. This is partially due to the physical scale of hardware and complexity of that hardware's integration into UAS. The current study is part of a larger research effort to integrate a high-gain parabolic microphone into a UAV (unmanned aerial vehicle) for use in acoustic surveying. Due to the aerodynamic interaction between a flush mounted parabolic antenna and the free-stream grazing flow, it is necessary to fair the antenna into the aircraft using a windscreen. The current study develops a characterization method by which various windscreen designs and configurations can be optimized. This method measures a candidate windscreen's normal incidence sound transmission loss (STL) as well as the increase of hydrodynamic noise generated by its installation at a range of flow speeds. A test apparatus was designed and installed on the Low Speed Wind Tunnel at Oklahoma State University. The test apparatus utilizes a "quiet box" attached to the wind tunnel test section floor. A pass-through window between the wind tunnel test section and the quiet box allows candidate wind screens to be mounted between the two environments. Microphones mounted both in the wind tunnel test section, and within the quiet box record the acoustic spectrum at various flow speeds, ranging between 36 and 81 feet per second. A tensioned KevlarRTM wind screen validation specimen was fabricated to validate system performance. The STL spectrum is measured based on comparing the signal from microphones on either side of the KevlarRTM membrane. The results for normal incidence STL for the flow off scenario are compared to results presented in other studies for the same material under tension. Flow-on transmission loss spectral data along with the increase in flow noise caused by the membrane is also measured at several flow speeds. The system has been shown to produce STL data consistent with the reference data for flow-on and flow-off test configurations, as well as being able to detect the increase in flow-induced noise generated by the validation specimen windscreen.
The Effects of Career Interruptions on Young Men and Women.
ERIC Educational Resources Information Center
Shorten, Brett; Lewis, Donald E.
1991-01-01
Data from a sample of 5,837 Australians showed that (1) women had longer career interruptions; (2) regardless of number of interruptions, men had higher wages; (3) longer interruptions had a negative effect on reentry wages; and (4) 1985-88 growth in wages for males was enhanced by increased numbers and length of interruptions, with the opposite…
Design of decision support interventions for medication prescribing.
Horsky, Jan; Phansalkar, Shobha; Desai, Amrita; Bell, Douglas; Middleton, Blackford
2013-06-01
Describe optimal design attributes of clinical decision support (CDS) interventions for medication prescribing, emphasizing perceptual, cognitive and functional characteristics that improve human-computer interaction (HCI) and patient safety. Findings from published reports on success, failures and lessons learned during implementation of CDS systems were reviewed and interpreted with regard to HCI and software usability principles. We then formulated design recommendations for CDS alerts that would reduce unnecessary workflow interruptions and allow clinicians to make informed decisions quickly, accurately and without extraneous cognitive and interactive effort. Excessive alerting that tends to distract clinicians rather than provide effective CDS can be reduced by designing only high severity alerts as interruptive dialog boxes and less severe warnings without explicit response requirement, by curating system knowledge bases to suppress warnings with low clinical utility and by integrating contextual patient data into the decision logic. Recommended design principles include parsimonious and consistent use of color and language, minimalist approach to the layout of information and controls, the use of font attributes to convey hierarchy and visual prominence of important data over supporting information, the inclusion of relevant patient data in the context of the alert and allowing clinicians to respond with one or two clicks. Although HCI and usability principles are well established and robust, CDS and EHR system interfaces rarely conform to the best known design conventions and are seldom conceived and designed well enough to be truly versatile and dependable tools. These relatively novel interventions still require careful monitoring, research and analysis of its track record to mature. Clarity and specificity of alert content and optimal perceptual and cognitive attributes, for example, are essential for providing effective decision support to clinicians. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
PAs reduce rounding interruptions in the pediatric intensive care unit.
Hascall, Rebecca L; Perkins, R Serene; Kmiecik, Lauren; Gupta, Priya R; Shelak, Carolyn F; Demirel, Shaban; Buchholz, Mark T
2018-06-01
We investigated the proportion of encounters that were interrupted during family-centered rounds in the pediatric intensive care unit (PICU) to determine whether the use of a physician assistant (PA) significantly affected the proportion of interrupted encounters. We evaluated 2,657 rounding encounters in our 24-bed regional referral unit. The duration of each rounding encounter and total rounding duration were recorded. The presence or absence of a PA during each rounding encounter, the occurrence of an interruption, and other potential predictors of interruptions were recorded. The presence of a PA during PICU rounds was significantly associated (P < .001) with a 35.4% lower likelihood of an interruption. Family-centered rounds in the PICU are less likely to be interrupted when a PA is present. PAs help physicians and improve rounding efficiency by safely and effectively handling certain interruptions.
Li, Simon Y W; Magrabi, Farah; Coiera, Enrico
2012-01-01
To understand the complex effects of interruption in healthcare. As interruptions have been well studied in other domains, the authors undertook a systematic review of experimental studies in psychology and human-computer interaction to identify the task types and variables influencing interruption effects. 63 studies were identified from 812 articles retrieved by systematic searches. On the basis of interruption profiles for generic tasks, it was found that clinical tasks can be distinguished into three broad types: procedural, problem-solving, and decision-making. Twelve experimental variables that influence interruption effects were identified. Of these, six are the most important, based on the number of studies and because of their centrality to interruption effects, including working memory load, interruption position, similarity, modality, handling strategies, and practice effect. The variables are explained by three main theoretical frameworks: the activation-based goal memory model, prospective memory, and multiple resource theory. This review provides a useful starting point for a more comprehensive examination of interruptions potentially leading to an improved understanding about the impact of this phenomenon on patient safety and task efficiency. The authors provide some recommendations to counter interruption effects. The effects of interruption are the outcome of a complex set of variables and should not be considered as uniformly predictable or bad. The task types, variables, and theories should help us better to identify which clinical tasks and contexts are most susceptible and assist in the design of information systems and processes that are resilient to interruption.
Interruptions in emergency medicine: things are not always what they seem.
Walter, Scott R
2018-06-20
We have all felt the cognitive disjuncture of being interrupted during an important task. Most ED physicians will readily proffer the high frequency and/or burden of interruptions during their work, and of the many observational studies of interruptions in healthcare EDs do indeed have high interruption rates[2]. In experimental psychology, where many of these ideas originated, there is plenty of evidence that interruptions negatively affect performance. Interruptions have been associated with reduced performance on complex tasks[3,4], increased sequence errors[5], increased task completion time and augmented annoyance and anxiety[6]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
ICARUS: An Innovative Large LAR Detector for Neutrino Physics
NASA Astrophysics Data System (ADS)
Vignoli, C.; Barni, D.; Disdier, J. M.; Rampoldi, D.; Icarus Collaboration
2006-04-01
ICARUS is an international project that foresees the installation of very large LAr detectors inside the Gran Sasso underground laboratory in order to be sensitive to rare phenomena of particle physics. The detection technique is based on the collection of electrons produced by particle interactions in LAr by a matrix of thousands of thin wires. At the moment the project foresees the installation of a 600,000-kg vessel (T600). The total amount of LAr can be expanded in a modular way to masses of the order of 106 kg. The T600 houses two identical 300,000-kg Ar sub-cryostats that are aluminum boxes about 20-m long, 4-m high and 4-m wide. Safety requirements for the underground installation have led to a unique design for the vessels to prevent LAr spillages even in the case of inner cryostat failure. Electrons must drift over meters requiring the development of special gas and liquid Ar purification units to provide an extremely high LAr purity (better then 0.1 ppb). The cooling system has been designed to assure a high thermal uniformity in the detector volume (less than 1-K differential). The cryogenic system associated with the final ICARUS configuration is based on three N2 refrigerators, three 30-m3 tanks and pump driven two-phase N2 forced-flow cooling of the various sub-systems. The T600 was successfully tested in Pavia in 2001 and it is now under installation in Gran Sasso for final operation. The future mass expansion strategy is under investigation.
An architecture for intelligent task interruption
NASA Technical Reports Server (NTRS)
Sharma, D. D.; Narayan, Srini
1990-01-01
In the design of real time systems the capability for task interruption is often considered essential. The problem of task interruption in knowledge-based domains is examined. It is proposed that task interruption can be often avoided by using appropriate functional architectures and knowledge engineering principles. Situations for which task interruption is indispensable, a preliminary architecture based on priority hierarchies is described.
Schroers, Ginger
2018-06-26
The purpose of this review was to synthesize and summarize data gathered by direct observation of the characteristics of interruptions in the context of nursing medication administration in hospital settings. Interruptions are prevalent during the medication administration process performed by nurses in hospital settings and have been found to be associated with an increase in frequency and severity of nursing medication administration errors. In addition, interruptions decrease task efficiency, leading to longer medication administration completion times. Integrative review. The electronic databases Cumulative Index of Nursing and Allied Health Literature (CINAHL), PubMED, PsyARTICLES, and Google Scholar were searched using the terms "interruptions" AND "medication administration" AND "direct observation". Nine articles met the inclusion criteria. Interruptions are likely to occur at least once during nursing medication administration processes in hospital settings. This finding applies to medication administered to one patient, termed a medication pass, and medication administered to multiple patients, termed a mediation round. Interruptions are most commonly caused by another nurse, staff member, or are self-initiated, and last approximately one minute in length. A raised awareness among staff of the most common sources of interruptions may encourage changes that lead to a decrease in the occurrence of interruptions. In addition, nurse leaders can apply an understanding of the common characteristics of interruptions to guide research, policies, and educational methods aimed at interruption management strategies. The findings from this review can be used to guide the identification and development of targeted interventions and strategies that would have the most substantial impact to reduce and manage interruptions during medication administration. Interruption management strategies have the potential to lead to a decrease in medication errors and an increase in task efficiency. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Analysis of Smartphone Interruptions on Academic General Internal Medicine Wards
C.Wu, Robert
2017-01-01
Summary Introduction Hospital-based medical services are increasingly utilizing team-based pagers and smartphones to streamline communications. However, an unintended consequence may be higher volumes of interruptions potentially leading to medical error. There is likely a level at which interruptions are excessive and cause a ‘crisis mode’ climate. Methods We retrospectively collected phone, text messaging, and email interruptions directed to hospital-assigned smartphones on eight General Internal Medicine (GIM) teams at two tertiary care centres in Toronto, Ontario from April 2013 to September 2014. We also calculated the number of times these interruptions exceeded a pre-specified threshold per hour, termed ‘crisis mode’, defined as at least five interruptions in 30 minutes. We analyzed the correlation between interruptions and date, site, and patient volumes. Results A total of 187,049 interruptions were collected over an 18-month period. Daily weekday interruptions rose sharply in the morning, peaking between 11 AM to 12 PM and measuring 4.8 and 3.7 mean interruptions/hour at each site, respectively. Mean daily interruptions per team totaled 46.2 ± 3.6 at Site 1 and 39.2 ± 4.2 at Site 2. The ‘crisis mode’ threshold was exceeded, on average, 2.3 times/day per GIM team during weekdays. In a multivariable linear regression analysis, site (β6.43 CI95% 5.44 – 7.42, p<0.001), day of the week (with Friday having the most interruptions) (β0.481 CI95% 0.236 – 0.730, p<0.05) and patient census (β1.55 CI95% 1.42 – 1.67, p<0.05) were all predictive of daily interruption volume although there was a significant interaction effect between site and patient census (β-0.941 CI95% -1.18 – -0.703, p<0.05). Conclusion Interruptions were related to site-specific features, including volume, suggesting that future interventions should target the culture of individual hospitals. Excessive interruptions may have implications for patient safety especially when exceeding a maximal threshold over short periods of time. PMID:28066851
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ponce, Dan; Brambila, Rigo E.; Cengher, Mirela
The ECH Group at DIII-D has installed in-house engineered, FPGA-based, high voltage reference waveform generators on its gyrotron control systems to enhance the capabilities of the systems and replace obsolete equipment. The new hardware, named D-Wavegen, outputs 16-bit signals every microsecond and can respond to events and anomalies in real-time. These generators have been reliably pausing gyrotron rf output during periods of DIII-D plasma density that exceed the fault density trip level and restarting the rf output if the density falls below the trip level. While tightly monitoring gyrotron body current and internal pressure, D-Wavegen has also been reliably restarting,more » in a little over 10ms, gyrotrons that spontaneously ceased rf generation.« less
Ponce, Dan; Brambila, Rigo E.; Cengher, Mirela; ...
2017-10-19
The ECH Group at DIII-D has installed in-house engineered, FPGA-based, high voltage reference waveform generators on its gyrotron control systems to enhance the capabilities of the systems and replace obsolete equipment. The new hardware, named D-Wavegen, outputs 16-bit signals every microsecond and can respond to events and anomalies in real-time. These generators have been reliably pausing gyrotron rf output during periods of DIII-D plasma density that exceed the fault density trip level and restarting the rf output if the density falls below the trip level. While tightly monitoring gyrotron body current and internal pressure, D-Wavegen has also been reliably restarting,more » in a little over 10ms, gyrotrons that spontaneously ceased rf generation.« less
116 years of misplaced management: Portballintrae, Northern Ireland
NASA Astrophysics Data System (ADS)
Jackson, D. W. T.
2012-04-01
Portballintrae has had a protracted history of human interference ranging from small-scale sand removal to hard coastal engineering. A small, horse shoe embayment and a once popular seaside destination on the north coast of Northern Ireland, it has suffered from progressive sediment loss over the last 116 years. From a once sediment abundant system, with a wide sandy beach, it now contains only a limited amount of sand draped over bedrock and/or gravel substrate and a relatively narrow beach. Installation of an obtrusive pier in its western section is thought to have interrupted the natural hydrody-namics and set in motion a progressive longshore transport and re-moval of sand into deeper water. Successive hard engineering 'solutions' prompted through public pressure and engineers keen to do business, have been largely ineffectual, located within a sediment-starved beach system.
Road crossing designs and their impact on fish assemblages of Great Plains streams
Bouska, Wesley W.; Paukert, Craig P.
2010-01-01
A mark-recapture field study was conducted to determine fish passage at 5 concrete box culverts and 5 low-water crossings (concrete slabs vented by culverts) as well as 10 control sites (below a natural riffle) in Flint Hills streams of northeastern Kansas. Additionally, we tested the upstream passage of four fish species native to Great Plains streams (Topeka shiner Notropis topeka, green sunfish Lepomis cyanellus, red shiner Cyprinella lutrensis, and southern redbelly dace Phoxinus erythrogaster) through three simulated crossing designs (box culverts, round corrugated culverts, and natural rock riffles) at water velocities of 0.1 to 1.1 m/s in an experimental stream. The field study indicated that cyprinids were twice as likely to move upstream of box culverts than low-water crossings and 1.4 times as likely to move upstream of control reaches than any crossing type. The best models indicated that the proportion of cyprinids that moved upstream increased with decreased culvert slope and length, perching, and increased culvert width. Our controlled experiment indicated that fish can move through velocities up to 1.1 m/s in a 1.86-m simulated stream and that the proportion of fish that moved upstream did not differ among crossing designs for southern redbelly dace, green sunfish, or Topeka shiner; however, natural rock riffles had lower proportional movements (mean = 0.19) than the box (0.38) or corrugated culvert designs (0.43) for red shiners. Water velocity did not affect the proportional upstream movement of any species except that of Topeka shiners, which increased with water velocity. Crossing design alone may not determine fish passage, and water velocities up to 1.1 m/s may not affect the passage of many Great Plains fishes. Barriers to fish movement may be the result of other factors (e.g., perching, slope, and crossing length). The use of properly designed and installed crossings has promise in conserving Great Plains stream fishes.
NASA Astrophysics Data System (ADS)
Abdoulaye, D.; Koalaga, Z.; Zougmore, F.
2012-02-01
This paper deals with a key solution for power outages problem experienced by many African countries and this through grid-connected photovoltaic (PV) systems with batteries storage. African grids are characterized by an insufficient power supply and frequent interruptions. Due to this fact, users who especially use classical grid-connected photovoltaic systems are unable to profit from their installation even if there is sun. In this study, we suggest the using of a grid-connected photovoltaic system with batteries storage as a solution to these problems. This photovoltaic system works by injecting the surplus of electricity production into grid and can also deliver electricity as a stand-alone system with all security needed. To achieve our study objectives, firstly we conducted a survey of a real situation of one African electrical grid, the case of Burkina Faso (SONABEL: National Electricity Company of Burkina). Secondly, as study case, we undertake a sizing, a modeling and a simulation of a grid-connected PV system with batteries storage for the LAME laboratory at the University of Ouagadougou. The simulation shows that the proposed grid-connected system allows users to profit from their photovoltaic installation at any time even if the public electrical grid has some failures either during the day or at night.
Resident perceptions of the impact of paging on intraoperative education.
Rose, Joel S; Waibel, Brett H; Schenarts, Paul J
2012-06-01
Our purpose was to evaluate the impact of paging on perceptions of intraoperative learning. Intraoperative logs of pager interruptions were kept by surgical residents at a university hospital over a 30-day period. The postgraduate year, number of pages, category of caller, reason for call, and level of urgency were recorded during each operation. At the conclusion of each operation, residents also completed a two-item survey with responses on a 5-point scale (1 = strongly disagree to 5 = strongly agree), querying if interruptions negatively impacted the intraoperative experience and if a message taken by a third party was effective in limiting interruptions. Logs were completed for 124 of 204 operations. Fifty-five per cent of operations were interrupted at least once with 49 per cent interrupted two to five times and 6 per cent were interrupted six or more times. Junior residents had 69 per cent of their operations interrupted compared with 39 per cent of senior residents (P = 0.001). Ninety-two per cent of pages were nonurgent. Residents did not perceive pager interruptions negatively impacted their educational experience (mean 2.3) but were neutral with respect if messages taken by a third party decreased interruptions (mean 3.8). Although our hypothesis was that pager interruptions were frequent and disrupt resident education, our data demonstrate the opposite.
Workflow interruptions and mental workload in hospital pediatricians: an observational study.
Weigl, Matthias; Müller, Andreas; Angerer, Peter; Hoffmann, Florian
2014-09-24
Pediatricians' workload is increasingly thought to affect pediatricians' quality of work life and patient safety. Workflow interruptions are a frequent stressor in clinical work, impeding clinicians' attention and contributing to clinical malpractice. We aimed to investigate prospective associations of workflow interruptions with multiple dimensions of mental workload in pediatricians during clinical day shifts. In an Academic Children's Hospital a prospective study of 28 full shift observations was conducted among pediatricians providing ward coverage. The prevalence of workflow interruptions was based on expert observation using a validated observation instrument. Concurrently, Pediatricians' workload ratings were assessed with three workload dimensions of the well-validated NASA-Task Load Index: mental demands, effort, and frustration. Observed pediatricians were, on average, disrupted 4.7 times per hour. Most frequent were interruptions by colleagues (30.2%), nursing staff (29.7%), and by telephone/beeper calls (16.3%). Interruption measures were correlated with two workload outcomes of interest: frequent workflow interruptions were related to less cognitive demands, but frequent interruptions were associated with increased frustration. With regard to single sources, interruptions by colleagues showed the strongest associations to workload. The findings provide insights into specific pathways between different types of interruptions and pediatricians' mental workload. These findings suggest further research and yield a number of work and organization re-design suggestions for pediatric care.
Huckels-Baumgart, Saskia; Niederberger, Milena; Manser, Tanja; Meier, Christoph R; Meyer-Massetti, Carla
2017-10-01
The aim was to evaluate the impact of staff training and wearing safety vests as a combined intervention on interruptions during medication preparation and double-checking. Interruptions and errors during the medication process are common and an important issue for patient safety in the hospital setting. We performed a pre- and post-intervention pilot-study using direct structured observation of 26 nurses preparing and double-checking 431 medication doses (225 pre-intervention and 206 post-intervention) for 36 patients (21 pre-intervention and 15 post-intervention). With staff training and the introduction of safety vests, the interruption rate during medication preparation was reduced from 36.8 to 28.3 interruptions per hour and during double-checking from 27.5 to 15 interruptions per hour. This pilot-study showed that the frequency of interruptions decreased during the critical tasks of medication preparation and double-checking after the introduction of staff training and wearing safety vests as part of a quality improvement process. Nursing management should acknowledge interruptions as an important factor potentially influencing medication safety. Unnecessary interruptions can be successfully reduced by considering human and system factors and increasing both staff and nursing managers' awareness of 'interruptive communication practices' and implementing physical barriers. This is the first pilot-study specifically evaluating the impact of staff training and wearing safety vests on the reduction of interruptions during medication preparation and double-checking. © 2017 John Wiley & Sons Ltd.
Larcos, George; Prgomet, Mirela; Georgiou, Andrew; Westbrook, Johanna
2017-01-01
Background Errors by nuclear medicine technologists during the preparation of radiopharmaceuticals or at other times can cause patient harm and may reflect the impact of interruptions, busy work environments and deficient systems or processes. We aimed to: (a) characterise the rate and nature of interruptions technologists experience and (b) identify strategies that support safety. Methods We performed 100 hours of observation of 11 technologists at a major public hospital and measured the proportions of time spent in eight categories of work tasks, location of task, interruption rate and type and multitasking (tasks conducted in parallel). We catalogued specific safety-oriented strategies used by technologists. Results Technologists completed 5227 tasks and experienced 569 interruptions (mean, 4.5 times per hour; 95% CI 4.1 to 4.9). The highest interruption rate occurred when technologists were in transit between rooms (10.3 per hour (95% CI 8.3 to 12.5)). Interruptions during radiopharmaceutical preparation occurred a mean of 4.4 times per hour (95% CI 3.3 to 5.6). Most (n=426) tasks were interrupted once only and all tasks were resumed after interruption. Multitasking occurred 16.6% of the time. At least some interruptions were initiated by other technologists to convey important information and/or to render assistance. Technologists employed a variety of verbal and non-verbal strategies in all work areas (notably in the hot-lab) to minimise the impact of interruptions and optimise the safe conduct of procedures. Although most were due to individual choices, some strategies reflected overt or subliminal departmental policy. Conclusions Some interruptions appear beneficial. Technologists' self-initiated strategies to support safe work practices appear to be an important element in supporting a resilient work environment in nuclear medicine. PMID:27707869
The culture contributing to interruptions in the nursing work environment: An ethnography.
Hopkinson, Susan G; Wiegand, Debra L
2017-12-01
To understand the occurrence of interruptions within the culture of the medical nursing unit work environment. Interruptions may lead to errors in nursing work. Little is known about how the culture of the nursing work environment contributes to interruptions. A micro-focused ethnographic study was conducted. Data collection involved extensive observation of a nursing unit, 1:1 observations of nurses and follow-up interviews with the nurses. Data were analysed from unstructured field notes and interview transcripts. The definitions of interruption and culture guided coding, categorising and identification of themes. A framework was developed that describes the medical nursing unit as a complex culture full of unpredictable, nonlinear changes that affect the entire interconnected system, often in the form of an interruption. The cultural elements contributing to interruptions included (i) the value placed on excellence in patient care and meeting personal needs, (ii) the beliefs that the nurses had to do everything by themselves and that every phone call was important, (iii) the patterns of changing patients, patient transport and coordination of resources and (iv) the normative practices of communicating and adapting. Interruptions are an integral part of the culture of a medical nursing unit. Uniformly decreasing interruptions may disrupt current practices, such as communication to coordinate care, that are central to nursing work. In future research, the nursing work environment must be looked at through the lens of a complex system. Interventions to minimise the negative impact of interruptions must take into account the culture of the nursing as a complex adaptive system. Nurses should be educated on their own contribution to interruptions and issues addressed at a system level, rather than isolating the interruption as the central issue. © 2017 John Wiley & Sons Ltd.
Cavallari, Ilaria; Ruff, Christian T; Nordio, Francesco; Deenadayalu, Naveen; Shi, Minggao; Lanz, Hans; Rutman, Howard; Mercuri, Michele F; Antman, Elliott M; Braunwald, Eugene; Giugliano, Robert P
2018-04-15
Patients with atrial fibrillation (AF) who interrupt anticoagulation are at high risk of thromboembolism and death. Patients enrolled in the ENGAGE AF-TIMI 48 trial (randomized comparison of edoxaban vs. warfarin) who interrupted study anticoagulant for >3 days were identified. Clinical events (ischemic stroke/systemic embolism, major cardiac and cerebrovascular events [MACCE]) were analyzed from day 4 after interruption until day 34 or study drug resumption. During 2.8 years median follow-up, 13,311 (63%) patients interrupted study drug for >3 days. After excluding those who received open-label anticoagulation during the at-risk window, the population for analysis included 9148 patients. The rates of ischemic stroke/systemic embolism and MACCE post interruption were substantially greater than in patients who never interrupted (15.42 vs. 0.26 and 60.82 vs. 0.36 per 100 patient-years, respectively, p adj < .001). Patients who interrupted study drug for an adverse event (44.1% of the cohort), compared to those who interrupted for other reasons, had an increased risk of MACCE (HR adj 2.75; 95% CI 2.02-3.74, p < .0001), but similar rates of ischemic stroke/systemic embolism. Rates of clinical events after interruption of warfarin and edoxaban were similar. Interruption of study drug was frequent in patients with AF and was associated with a substantial risk of major cardiac and cerebrovascular events over the ensuing 30 days. This risk was particularly high in patients who interrupted as a result of an adverse event; these patients deserve close monitoring and resumption of anticoagulation as soon as it is safe to do so. Copyright © 2018 Elsevier B.V. All rights reserved.
Klemets, Joakim; Evjemo, Tor Erik
2014-09-01
Nurses' work in hospital departments is highly collaborative and includes communication with a variety of actors. To further support nurses' communications, wireless phones, on which nurses receive both nurse calls and ordinary phone calls, have been introduced. However, while they ensure high availability among the mobile nurses, these phones also contribute to an increased number of interruptions. This paper aims to discover whether all interruptions caused by the wireless phones are unwanted. Further, it investigates how nurses handle these interruptions in a hospital setting in order to construct a foundation for guidelines to use in designing these types of systems. Qualitative and ethnographically inspired fieldwork, including workshops with both ordinary and student nurses from a Norwegian hospital, was undertaken. Patients from two hospital departments were interviewed. Nurses struggle to handle interruptions caused by the wireless nurse call system. Deciding whether to abort an activity or not to respond to an interruption is regarded as stressful. The decision is further complicated by the complex nature of the interruptions. At the same time, patients anticipate that nurses are able to make these judgements with limited information. Nurses' work is highly collaborative, and nurses depend on one another to carry out their work and manage interruptions. The dual nature of the interruptions is complex, and whether an interruption is wanted or unwanted depends on many factors. Nurses manage interruptions mainly by making their own activities visible and monitoring colleagues' work. Therefore, nurses' awareness of colleagues' activities is a key factor in how they handle interruptions in the form of nurse calls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Sub-cooled liquid nitrogen cryogenic system with neon turbo-refrigerator for HTS power equipment
NASA Astrophysics Data System (ADS)
Yoshida, S.; Hirai, H.; Nara, N.; Ozaki, S.; Hirokawa, M.; Eguchi, T.; Hayashi, H.; Iwakuma, M.; Shiohara, Y.
2014-01-01
We developed a prototype sub-cooled liquid nitrogen (LN) circulation system for HTS power equipment. The system consists of a neon turbo-Brayton refrigerator with a LN sub-cooler and LN circulation pump unit. The neon refrigerator has more than 2 kW cooling power at 65 K. The LN sub-cooler is a plate-fin type heat exchanger and is installed in a refrigerator cold box. In order to carry out the system performance tests, a dummy cryostat having an electric heater was set instead of a HTS power equipment. Sub-cooled LN is delivered into the sub-cooler by the LN circulation pump and cooled within it. After the sub-cooler, sub-cooled LN goes out from the cold box to the dummy cryostat, and comes back to the pump unit. The system can control an outlet sub-cooled LN temperature by adjusting refrigerator cooling power. The refrigerator cooling power is automatically controlled by the turbo-compressor rotational speed. In the performance tests, we increased an electric heater power from 200 W to 1300 W abruptly. We confirmed the temperature fluctuation was about ±1 K. We show the cryogenic system details and performance test results in this paper.
Non-invasive monitoring of the degradation of organic contaminants: A laboratory investigation
NASA Astrophysics Data System (ADS)
Fernandez, Perrine M.; Bloem, Esther; Philippe, Romain; Binley, Andrew; French, Helen K.
2016-04-01
Degradation of organic chemicals under various fluid saturation conditions is a process highly relevant to the protection of groundwater quality. Redox potential drives the degradation of organic compounds; its variation affects the water chemistry, gas release and also the geo-electrical signature. This study explores how non-invasive measurements sensitive to geo-electrical properties provides quantitative information about the in-situ redox conditions. Our laboratory experiment focuses on the degradation of de-icing chemicals commonly used, for example, in Norwegian airports. The experiment was conducted in a number of (1.0x0.5x0.4 m) sand boxes. Two ends of each box was contaminated with propylene glycol, an aircraft deicing fluid. Each source was placed near the water table under static hydraulic conditions. At one side of the tank, a conductor linking the contamination zone, near the water table and the unsaturated zone with a low water content, was placed to improve the degradation by facilitating the electron exchange. At the other side, degradation occurred under natural conditions. Each box was equipped with 288 electrodes, distributed on six faces to perform 3D resistivity measurements. In addition, self-potential measurements were taken from electrodes on the sand surface. Four observation wells were installed above and below the water table to provide more information on the degradation processes. Moreover, measurements of carbon dioxide on the surface were performed as higher concentrations were expected where the pollutant degraded. We would like to present and discuss a selection of the preliminary results of 3D electrical resistivity and self-potential techniques from our laboratory setup.
Interruptions in a level one trauma center: a case study.
Brixey, Juliana J; Tang, Zhihua; Robinson, David J; Johnson, Craig W; Johnson, Todd R; Turley, James P; Patel, Vimla L; Zhang, Jiajie
2008-04-01
The emergency department has been characterized as interrupt-driven. Government agencies and patient safety organizations recognize that interruptions contribute to medical errors. The purpose of this study was to observe, record, and contextualize activities and interruptions experienced by physicians and Registered Nurses (RNs) working in a Level One Trauma Center. A case study that relied on an ethnographic study design using the shadowing method. A convenience sample of physicians and RNs, each with at least 6 months of experience in the Emergency Department (ED), were asked to participate. In these kinds of detailed qualitative investigations, it is quite common to have a small sample size. Ethical approval: Approval was obtained from institutional ethic committees prior to initiating the study. Community consent was obtained from the ED staff through in-service education. All observations were made in the trauma section of the ED of a tertiary teaching hospital. The hospital is situated in a major medical center in the Gulf Coast region of the United States of America (USA). Five attending ED physicians were observed for a total of 29h, 31min. Eight RNs were shadowed for a total of 40 h, 9min. Interruptions and activities were categorized using the Hybrid Method to Categorize Interruptions and Activities (HyMCIA). Registered Nurses received slightly more interruptions per hour than physicians. People, pagers, and telephones were identified as mediums through which interruptions were delivered. The physical environment was found to contribute to interruptions in workflow because of physical design and when supplies were not available. Physicians and RNs usually returned to the original, interrupted activity more often than leaving the activity unfinished. This research provides an enhanced understanding of interruptions in workflow in the ED, the identification of work constraints, and the need to develop interventions to manage interruptions. It is crucial that interruptions be delivered in such a way that there is minimal negative impact on performance. The significance and importance of the interruption must always be weighed against the negative impact that it has on smooth, efficient workflow.
NASA Astrophysics Data System (ADS)
Tondji Chendjou, Yvan Wilfried
This Master's thesis is written within the framework of the multidisciplinary international research project CRIAQ MDO-505. This global project consists of the design, manufacture and testing of a morphing wing box capable of changing the shape of the flexible upper skin of a wing using an actuator system installed inside the wing. This changing of the shape generates a delay in the occurrence of the laminar to turbulent transition area, which results in an improvement of the aerodynamic performances of the morphed wing. This thesis is focused on the technologies used to gather the pressure data during the wind tunnel tests, as well as on the post processing methodologies used to characterize the wing airflow. The vibration measurements of the wing and their real-time graphical representation are also presented. The vibration data acquisition system is detailed, and the vibration data analysis confirms the predictions of the flutter analysis performed on the wing prior to wind tunnel testing at the IAR-NRC. The pressure data was collected using 32 highly-sensitive piezoelectric sensors for sensing the pressure fluctuations up to 10 KHz. These sensors were installed along two wing chords, and were further connected to a National Instrument PXI real-time acquisition system. The acquired pressure data was high-pass filtered, analyzed and visualized using Fast Fourier Transform (FFT) and Standard Deviation (SD) approaches to quantify the pressure fluctuations in the wing airflow, as these allow the detection of the laminar to turbulent transition area. Around 30% of the cases tested in the IAR-NRC wind tunnel were optimized for drag reduction by the morphing wing procedure. The obtained pressure measurements results were compared with results obtained by infrared thermography visualization, and were used to validate the numerical simulations. Two analog accelerometers able to sense dynamic accelerations up to +/-16g were installed in both the wing and the aileron boxes to obtain the vibration sensing measurements. The measured accelerations were acquired by an NI real-time acquisition system using LABVIEW software for a real-time graphical visualization. The recorded data were then analyzed and the analysis indicated that no aeroelastic phenomenon occurred on the model during the wind tunnel tests, at speeds of 50 m/s and 80m/s.
Fine root dynamics in moso bamboo and Japanese cedar forest by scanner method in central Taiwan
NASA Astrophysics Data System (ADS)
Chen, Zhi-Wei; Lin, Po-Hsuan; Kume, Tomonori
2017-04-01
Phyllostachys pubescens is one of the most important economic plant in the world. Phyllostachys pubescens originates from China and it had been introduced to neighbor countries about three hundred ago due to its economic value. But substantial bamboo forests were abandoned due to declines in demand. These unmanaged bamboo forests have been expanding to adjacent original forests in northern Taiwan. This vegetation alternation may not only decrease the local biodiversity but also affect the carbon cycle. Fine roots are responsible for water and nutrients acquisition and forming the most active part of the whole root system. The characteristics of fine roots are non-woody, small diameter and short lifespan. When roots keep producing new roots and replacing old roots, carbon and nutrients was transported into soil. Consequently, fine root production is one of the important component to understand the below-ground carbon cycle. However, there is few studies about fine root production in moso bamboo forests. We still lack effective method to obtain quantitative and objective data in Taiwan. It severely limits us to understand the below-ground carbon dynamics there. Minirhizotrons method has been used to investigate fine root dynamics by inserting transparent tubes into soil and by comparing changes in root length in images taken by micro-camera. But this method has some shortcomings; i.e. Most of image analysis are conducted manually and time-consuming. And it is difficult to estimate the stand level fine root production from small observation view. A new method "scanner method", which collect A4-size image (bigger than minirhizotrons) can overcome some parts of the shortcoming of minirhizotrons. The transparent acrylic box with A4-box view is inserted into soil and the interface between soil and box is scanned by commercial scanner. We can monitor the total projected root area, growth and decomposition separately by series of images. The primary objective of this study is to characterize the temporal and spatial variation of fine root dynamics in moso bamboo forests in central Taiwan by using scanner method with 6 acrylic boxes. Other the other hand, this study compared the result with those of adjacent Japanese cedar forests with 8 acrylic boxes. Consequently, we found the fine root production rate and decomposition rate of the bamboo forest are higher than cedar forest. Also, the timing of first observation of new roots was earlier in bamboo forest than cedar forest. This study also examined differences of temporal patterns among measurement locations based on long-term data after box installation.
Bill Parsons with Discovery Processing Team
2003-08-29
Mark McGee (right) shows the bead blasting completed on the rudder speed brake on orbiter Discovery to Shuttle Program Manager Bill Parsons (center). McGee is manager, Orbiter Processing Facility, with United Space Alliance. At left is Mark Nappi, deputy associate program manager, ground operations, USA. The work was part of Orbiter Major Modifications (OMM) that were recently completed on Discovery. The OMM work ranged from wiring, control panels and black boxes to gaseous and fluid systems tubing and components. These systems were deserviced, disassembled, inspected, modified, reassembled, checked out and reserviced, as were most other systems onboard. The work included the installation of the Multifunction Electronic Display Subsystem (MEDS) - a state-of-the-art “glass cockpit.”
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chua, S.E.; Abito, G.F.
A 1-MWt multi-crop drying facility using low-enthalpy waste geothermal heat is installed within the vicinity of the Southern Negros Geothermal Project (January, 1994). The plant is envisioned to demonstrate the direct use of geothermal resources for agro-industrial purposes and at the same time, provide major benefits by raising the quality of the agro-industrial products to meet higher standards. The development and design of the heat exchangers that supply the heat and the dryer used in the facility is presented. The process flow and the dryer parameters in the drying of coconut meat and other crops have been determined. The initialmore » design of the dryers target the dehydration of coconut meat and other crops using boxes and trays.« less
Durability of aircraft composite materials
NASA Technical Reports Server (NTRS)
Dextern, H. B.
1982-01-01
Confidence in the long term durability of advanced composites is developed through a series of flight service programs. Service experience is obtained by installing secondary and primary composite components on commercial and military transport aircraft and helicopters. Included are spoilers, rudders, elevators, ailerons, fairings and wing boxes on transport aircraft and doors, fairings, tail rotors, vertical fins, and horizontal stabilizers on helicopters. Materials included in the evaluation are boron/epoxy, Kevlar/epoxy, graphite/epoxy and boron/aluminum. Inspection, maintenance, and repair results for the components in service are reported. The effects of long term exposure to laboratory, flight, and outdoor environmental conditions are reported for various composite materials. Included are effects of moisture absorption, ultraviolet radiation, and aircraft fuels and fluids.
Evaluation of Interruption Behavior by Naive Encoders.
ERIC Educational Resources Information Center
Coon, Christine A.; Schwanenflugel, Paula J.
1996-01-01
Determines the characteristics of interactions that influence judgments of interruption behavior in naive observers. Asks subjects to decide whether an example of an interruption was an interruption and then rate it in terms of how "good" or "bad" it was. Finds that naive observers use some of the same features described in…
NASA Astrophysics Data System (ADS)
Inada, Yuki; Kamiya, Tomoki; Matsuoka, Shigeyasu; Kumada, Akiko; Ikeda, Hisatoshi; Hidaka, Kunihiko
2018-01-01
Two-dimensional electron density imaging over free burning SF6 arcs and SF6 gas-blast arcs was conducted at current zero using highly sensitive Shack-Hartmann type laser wavefront sensors in order to experimentally characterise electron density distributions for the success and failure of arc interruption in the thermal reignition phase. The experimental results under an interruption probability of 50% showed that free burning SF6 arcs with axially asymmetric electron density profiles were interrupted with a success rate of 88%. On the other hand, the current interruption of SF6 gas-blast arcs was reproducibly achieved under locally reduced electron densities and the interruption success rate was 100%.
Interruption of the Tower of London Task: Support for a Goal-Activation Approach
ERIC Educational Resources Information Center
Hodgetts, Helen M.; Jones, Dylan M.
2006-01-01
Unexpected interruptions introduced during the execution phase of simple Tower of London problems incurred a time cost when the interrupted goal was retrieved, and this cost was exacerbated the longer the goal was suspended. Furthermore, time taken to retrieve goals was greater following a more complex interruption, indicating the processing…
Determining the Overall Impact of Interruptions during Online Testing
ERIC Educational Resources Information Center
Sinharay, Sandip; Wan, Ping; Whitaker, Mike; Kim, Dong-In; Zhang, Litong; Choi, Seung W.
2014-01-01
With an increase in the number of online tests, interruptions during testing due to unexpected technical issues seem unavoidable. For example, interruptions occurred during several recent state tests. When interruptions occur, it is important to determine the extent of their impact on the examinees' scores. There is a lack of research on this…
Parabolic Trough Collector Cost Update for the System Advisor Model (SAM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurup, Parthiv; Turchi, Craig S.
2015-11-01
This report updates the baseline cost for parabolic trough solar fields in the United States within NREL's System Advisor Model (SAM). SAM, available at no cost at https://sam.nrel.gov/, is a performance and financial model designed to facilitate decision making for people involved in the renewable energy industry. SAM is the primary tool used by NREL and the U.S. Department of Energy (DOE) for estimating the performance and cost of concentrating solar power (CSP) technologies and projects. The study performed a bottom-up build and cost estimate for two state-of-the-art parabolic trough designs -- the SkyTrough and the Ultimate Trough. The SkyTroughmore » analysis estimated the potential installed cost for a solar field of 1500 SCAs as $170/m 2 +/- $6/m 2. The investigation found that SkyTrough installed costs were sensitive to factors such as raw aluminum alloy cost and production volume. For example, in the case of the SkyTrough, the installed cost would rise to nearly $210/m 2 if the aluminum alloy cost was $1.70/lb instead of $1.03/lb. Accordingly, one must be aware of fluctuations in the relevant commodities markets to track system cost over time. The estimated installed cost for the Ultimate Trough was only slightly higher at $178/m 2, which includes an assembly facility of $11.6 million amortized over the required production volume. Considering the size and overall cost of a 700 SCA Ultimate Trough solar field, two parallel production lines in a fully covered assembly facility, each with the specific torque box, module and mirror jigs, would be justified for a full CSP plant.« less
Sullivan, Jessica R.; Thibodeau, Linda M.; Assmann, Peter F.
2013-01-01
Previous studies have indicated that individuals with normal hearing (NH) experience a perceptual advantage for speech recognition in interrupted noise compared to continuous noise. In contrast, adults with hearing impairment (HI) and younger children with NH receive a minimal benefit. The objective of this investigation was to assess whether auditory training in interrupted noise would improve speech recognition in noise for children with HI and perhaps enhance their utilization of glimpsing skills. A partially-repeated measures design was used to evaluate the effectiveness of seven 1-h sessions of auditory training in interrupted and continuous noise. Speech recognition scores in interrupted and continuous noise were obtained from pre-, post-, and 3 months post-training from 24 children with moderate-to-severe hearing loss. Children who participated in auditory training in interrupted noise demonstrated a significantly greater improvement in speech recognition compared to those who trained in continuous noise. Those who trained in interrupted noise demonstrated similar improvements in both noise conditions while those who trained in continuous noise only showed modest improvements in the interrupted noise condition. This study presents direct evidence that auditory training in interrupted noise can be beneficial in improving speech recognition in noise for children with HI. PMID:23297921
Radiation therapy interruption in a poor resource setting: causes and management..
Akinlade, B I; Folasire, A M; Elumelu-Kupoluyi, T N; Adenipekun, A A; Iyobosa, U B; Campbell, O B
2014-12-01
Treatment interruption is the failure to execute approved treatment plan of a patient. This adversely affects treatment outcomeif not properly managed. This retrospective study causes and management of radiation treatment interruptions during High Dose Rate Brachytherapy(HDRB) for carcinoma of the cervix in a teaching hospital in Nigeria. Five hundred patients with cervical carcinoma, who received HDRB, post external beam radiotherapy, between August, 2008 and July, 2013 were assessed. They were grouped into (A): those who experienced treatment interruption and (B): those who did not. Each patient was scheduled to receive three fractions of HDRB over 3 weeks. Those in groups A were assessed for the exact treatment fraction missed, the cause and duration of treatment interruption and the actions taken to compensate for non-execution of treatment. A total of 90 patients fall into group A and most (41) of them experienced interruptions in the third fraction of their treatment. The most frequent (44%) causes of treatment interruptions observed among them were patient-related. Record of compensation for treatment interruption was not found in patients' treatment folders. This action may be due to lack of functional procedures for managing treatment interruptions and insufficient follow-up of patients, who never came back for consideration for compensation. This study showed that radiation oncology centres need to review their policies for managing treatment interruptions and documentation. Also, the mechanism for patients' follow-up should be strengthened to a reasonable extent to achieve better radiotherapy care.
The Effect of Interruptions on Part 121 Air Carrier Operations
NASA Technical Reports Server (NTRS)
Damos, Diane L.
1998-01-01
The primary purpose of this study was to determine the relative priorities of various events and activities by examining the probability that a given activity was interrupted by a given event. The analysis will begin by providing frequency of interruption data by crew position (captain versus first officer) and event type. Any differences in the pattern of interruptions between the first officers and the captains will be explored and interpreted in terms of standard operating procedures. Subsequent data analyses will focus on comparing the frequency of interruptions for different types of activities and for the same activities under normal versus emergency conditions. Briefings and checklists will receive particular attention. The frequency with which specific activities are interrupted under multiple- versus single-task conditions also will be examined; because the majority of multiple-task data were obtained under laboratory conditions, LOFT-type tapes offer a unique opportunity to examine concurrent task performance under 'real-world' conditions. A second purpose of this study is to examine the effects of the interruptions on performance. More specifically, when possible, the time to resume specific activities will be compared to determine if pilots are slower to resume certain types of activities. Errors in resumption or failures to resume specific activities will be noted and any patterns in these errors will be identified. Again, particular attention will be given to the effects of interruptions on the completion of checklists and briefings. Other types of errors and missed events (i.e., the crew should have responded to the event but did not) will be examined. Any methodology using interruptions to examine task prioritization must be able to identify when an interruption has occurred and describe the ongoing activities that were interrupted. Both of these methodological problems are discussed In detail in the following section,
Bowden, Vanessa K; Visser, Troy A W; Loft, Shayne
2017-06-01
It is generally assumed that drivers speed intentionally because of factors such as frustration with the speed limit or general impatience. The current study examined whether speeding following an interruption could be better explained by unintentional prospective memory (PM) failure. In these situations, interrupting drivers may create a PM task, with speeding the result of drivers forgetting their newly encoded intention to travel at a lower speed after interruption. Across 3 simulated driving experiments, corrected or uncorrected speeding in recently reduced speed zones (from 70 km/h to 40 km/h) increased on average from 8% when uninterrupted to 33% when interrupted. Conversely, the probability that participants traveled under their new speed limit in recently increased speed zones (from 40 km/h to 70 km/h) increased from 1% when uninterrupted to 23% when interrupted. Consistent with a PM explanation, this indicates that interruptions lead to a general failure to follow changed speed limits, not just to increased speeding. Further testing a PM explanation, Experiments 2 and 3 manipulated variables expected to influence the probability of PM failures and subsequent speeding after interruptions. Experiment 2 showed that performing a cognitively demanding task during the interruption, when compared with unfilled interruptions, increased the probability of initially speeding from 1% to 11%, but that participants were able to correct (reduce) their speed. In Experiment 3, providing participants with 10s longer to encode the new speed limit before interruption decreased the probability of uncorrected speeding after an unfilled interruption from 30% to 20%. Theoretical implications and implications for road design interventions are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Medication administration and interruptions in nursing homes: A qualitative observational study.
Odberg, Kristian Ringsby; Hansen, Britt Saetre; Aase, Karina; Wangensteen, Sigrid
2018-03-01
To contribute in-depth knowledge of the characteristics of medication administration and interruptions in nursing homes. The following research questions guided the study: How can the medication administration process in nursing homes be described? How can interruptions during the medication administration process in nursing homes be characterized? Medication administration is a vital process across healthcare settings, and earlier research in nursing homes is sparse. The medication administration process is prone to interruptions that may lead to adverse drug events. On the other hand, interruptions may also have positive effects on patient safety. A qualitative observational study design was applied. Data were collected using partial participant observations. An inductive content analysis was performed. Factors that contributed to the observed complexity of medication administration in nursing homes were the high number of single tasks, varying degree of linearity, the variability of technological solutions, demands regarding documentation and staff's apparent freedom as to how and where to perform medication-related activities. Interruptions during medication administration are prevalent and can be characterised as passive (e.g., alarm and background noises), active (e.g., discussions) or technological interruptions (e.g., use of mobile applications). Most interruptions have negative outcomes, while some have positive outcomes. A process of normalisation has taken place whereby staff put up with second-rate technological solutions, noise and interruptions when they are performing medication-related tasks. Before seeking to minimise interruptions during the medication administration process, it is important to understand the interconnectivity of the elements using a systems approach. Staff and management need to be aware of the normalisation of interruptions. Knowledge of the complexity of medication administration may raise awareness and highlight the importance of maintaining and enhancing staff competence. © 2017 John Wiley & Sons Ltd.
Blancas, A; González-García, S D; Rodríguez, K; Escobar, C
2014-12-05
Scheduled and restricted access to a palatable snack, i.e. chocolate, elicits a brief and strong anticipatory activation and entrains brain areas related with reward and motivation. This behavioral and neuronal activation persists for more than 7days when this protocol is interrupted, suggesting the participation of a time-keeping system. The process that initiates this anticipation may provide a further understanding of the time-keeping system underlying palatable food entrainment. The aim of this study was to analyze how this entraining protocol starts and to dissect neuronal structures that initiate a chocolate-entrained activation. We assessed the development of anticipation of 5g of chocolate during the first 8days of the entrainment protocol. General activity of control and chocolate-entrained rats was continuously monitored with movement sensors. Moreover, motivation to obtain the chocolate was assessed by measuring approaches and interaction responses toward a wire-mesh box containing chocolate. Neuronal activation was determined with c-Fos in reward-related brain areas. We report a progressive increase in the interaction with a box to obtain chocolate parallel to a progressive neuronal activation. A significant anticipatory activation was observed in the prefrontal cortex on day 3 of entrainment and in the nucleus accumbens on day 5, while the arcuate nucleus and pyriform cortex reached significant activation on day 8. The gradual response observed with this protocol indicates that anticipation of a rewarding food requires repetitive and predictable experiences in order to acquire a temporal estimation. We also confirm that anticipation of palatable food involves diverse brain regions. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Peters, R; King, C Y; Ukiyama, E; Falsafi, S; Donahoe, P K; Weiss, M A
1995-04-11
SRY, a genetic "master switch" for male development in mammals, exhibits two biochemical activities: sequence-specific recognition of duplex DNA and sequence-independent binding to the sharp angles of four-way DNA junctions. Here, we distinguish between these activities by analysis of a mutant SRY associated with human sex reversal (46, XY female with pure gonadal dysgenesis). The substitution (168T in human SRY) alters a nonpolar side chain in the minor-groove DNA recognition alpha-helix of the HMG box [Haqq, C.M., King, C.-Y., Ukiyama, E., Haqq, T.N., Falsalfi, S., Donahoe, P.K., & Weiss, M.A. (1994) Science 266, 1494-1500]. The native (but not mutant) side chain inserts between specific base pairs in duplex DNA, interrupting base stacking at a site of induced DNA bending. Isotope-aided 1H-NMR spectroscopy demonstrates that analogous side-chain insertion occurs on binding of SRY to a four-way junction, establishing a shared mechanism of sequence- and structure-specific DNA binding. Although the mutant DNA-binding domain exhibits > 50-fold reduction in sequence-specific DNA recognition, near wild-type affinity for four-way junctions is retained. Our results (i) identify a shared SRY-DNA contact at a site of either induced or intrinsic DNA bending, (ii) demonstrate that this contact is not required to bind an intrinsically bent DNA target, and (iii) rationalize patterns of sequence conservation or diversity among HMG boxes. Clinical association of the I68T mutation with human sex reversal supports the hypothesis that specific DNA recognition by SRY is required for male sex determination.
Laurence, S; Peterken, R; Burns, C
2007-09-01
The Fresh Kids programme utilized the Health Promoting Schools (HPSs) framework to design a whole-of-school, multifaceted intervention targeting specific behaviours to promote healthy eating and reduce the risk factors associated with childhood obesity. The aim of the programme was to evaluate the effectiveness of the HPS framework to increase fruit and water consumption among primary school-aged children over a 2-year period. The study design was an interrupted time series. Four primary schools in the inner west of Melbourne, Australia, participated in the programme intervention. Baseline data were collected using a lunch box audit to assess the frequency of children with fresh fruit, water and sweet drinks, either brought from home or selected from canteen lunch orders. The lunch box audit was repeated periodically for up to 2 years following programme implementation to assess the sustainability of dietary changes. Across all participating schools, significant increases between 25 and 50% were observed in the proportion of children bringing fresh fruit. Similarly, all schools recorded increases between 15 and 60% in the proportion of students bringing filled water bottles to school and reductions between 8 and 38% in the proportion of children bringing sweet drinks. These significant changes in dietary patterns were sustained for up to 2 years following programme implementation. Targeting key nutrition behaviours and using the HPS framework is an effective and simple approach which could be readily implemented in similar childhood settings. Effective strategies include facilitating organizational change within the school; integrating curriculum activities; formalizing school policy and establishing project partnerships with local community nutrition and dietetic services.
Sri, Tanu; Mayee, Pratiksha; Singh, Anandita
2015-09-01
Whole genome sequence analyses allow unravelling such evolutionary consequences of meso-triplication event in Brassicaceae (∼14-20 million years ago (MYA)) as differential gene fractionation and diversification in homeologous sub-genomes. This study presents a simple gene-centric approach involving microsynteny and natural genetic variation analysis for understanding SUPPRESSOR of OVEREXPRESSION of CONSTANS 1 (SOC1) homeolog evolution in Brassica. Analysis of microsynteny in Brassica rapa homeologous regions containing SOC1 revealed differential gene fractionation correlating to reported fractionation status of sub-genomes of origin, viz. least fractionated (LF), moderately fractionated 1 (MF1) and most fractionated (MF2), respectively. Screening 18 cultivars of 6 Brassica species led to the identification of 8 genomic and 27 transcript variants of SOC1, including splice-forms. Co-occurrence of both interrupted and intronless SOC1 genes was detected in few Brassica species. In silico analysis characterised Brassica SOC1 as MADS intervening, K-box, C-terminal (MIKC(C)) transcription factor, with highly conserved MADS and I domains relative to K-box and C-terminal domain. Phylogenetic analyses and multiple sequence alignments depicting shared pattern of silent/non-silent mutations assigned Brassica SOC1 homologs into groups based on shared diploid base genome. In addition, a sub-genome structure in uncharacterised Brassica genomes was inferred. Expression analysis of putative MF2 and LF (Brassica diploid base genome A (AA)) sub-genome-specific SOC1 homeologs of Brassica juncea revealed near identical expression pattern. However, MF2-specific homeolog exhibited significantly higher expression implying regulatory diversification. In conclusion, evidence for polyploidy-induced sequence and regulatory evolution in Brassica SOC1 is being presented wherein differential homeolog expression is implied in functional diversification.
RNomics in Archaea reveals a further link between splicing of archaeal introns and rRNA processing
Tang, Thean Hock; Rozhdestvensky, Timofey S.; d’Orval, Béatrice Clouet; Bortolin, Marie-Line; Huber, Harald; Charpentier, Bruno; Branlant, Christiane; Bachellerie, Jean-Pierre; Brosius, Jürgen; Hüttenhofer, Alexander
2002-01-01
The bulge–helix–bulge (BHB) motif recognised by the archaeal splicing endonuclease is also found in the long processing stems of archaeal rRNA precursors in which it is cleaved to generate pre-16S and pre-23S rRNAs. We show that in two species, Archaeoglobus fulgidus and Sulfolobus solfataricus, representatives from the two major archaeal kingdoms Euryarchaeota and Crenarchaeota, respectively, the pre-rRNA spacers cleaved at the BHB motifs surrounding pre-16S and pre-23S rRNAs subsequently become ligated. In addition, we present evidence that this is accompanied by circularisation of ribosomal pre-16S and pre-23S rRNAs in both species. These data reveal a further link between intron splicing and pre-rRNA processing in Archaea, which might reflect a common evolutionary origin of the two processes. One spliced RNA species designated 16S-D RNA, resulting from religation at the BHB motif of 16S pre-rRNA, is a highly abundant and stable RNA which folds into a three-stem structure interrupted by two single-stranded regions as assessed by chemical probing. It spans a region of the pre-rRNA 5′ external transcribed spacer exhibiting a highly conserved folding pattern in Archaea. Surprisingly, 16S-D RNA contains structural motifs found in archaeal C/D box small RNAs and binds to the L7Ae protein, a core component of archaeal C/D box RNPs. This supports the notion that it might have an important but still unknown role in pre-rRNA biogenesis or might even target RNA molecules other than rRNA. PMID:11842103
Larcos, George; Prgomet, Mirela; Georgiou, Andrew; Westbrook, Johanna
2017-06-01
Errors by nuclear medicine technologists during the preparation of radiopharmaceuticals or at other times can cause patient harm and may reflect the impact of interruptions, busy work environments and deficient systems or processes. We aimed to: (a) characterise the rate and nature of interruptions technologists experience and (b) identify strategies that support safety. We performed 100 hours of observation of 11 technologists at a major public hospital and measured the proportions of time spent in eight categories of work tasks, location of task, interruption rate and type and multitasking (tasks conducted in parallel). We catalogued specific safety-oriented strategies used by technologists. Technologists completed 5227 tasks and experienced 569 interruptions (mean, 4.5 times per hour; 95% CI 4.1 to 4.9). The highest interruption rate occurred when technologists were in transit between rooms (10.3 per hour (95% CI 8.3 to 12.5)). Interruptions during radiopharmaceutical preparation occurred a mean of 4.4 times per hour (95% CI 3.3 to 5.6). Most (n=426) tasks were interrupted once only and all tasks were resumed after interruption. Multitasking occurred 16.6% of the time. At least some interruptions were initiated by other technologists to convey important information and/or to render assistance. Technologists employed a variety of verbal and non-verbal strategies in all work areas (notably in the hot-lab) to minimise the impact of interruptions and optimise the safe conduct of procedures. Although most were due to individual choices, some strategies reflected overt or subliminal departmental policy. Some interruptions appear beneficial. Technologists' self-initiated strategies to support safe work practices appear to be an important element in supporting a resilient work environment in nuclear medicine. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Westbrook, Johanna I; Li, Ling; Hooper, Tamara D; Raban, Magda Z; Middleton, Sandy; Lehnbom, Elin C
2017-09-01
To evaluate the effectiveness of a 'Do not interrupt' bundled intervention to reduce non-medication-related interruptions to nurses during medication administration. A parallel eight cluster randomised controlled study was conducted in a major teaching hospital in Adelaide, Australia. Four wards were randomised to the intervention which comprised wearing a vest when administering medications; strategies for diverting interruptions; clinician and patient education; and reminders. Control wards were blinded to the intervention. Structured direct observations of medication administration processes were conducted. The primary outcome was non-medication-related interruptions during individual medication dose administrations. The secondary outcomes were total interruption and multitasking rates. A survey of nurses' experiences was administered. Over 8 weeks and 364.7 hours, 227 nurses were observed administering 4781 medications. At baseline, nurses experienced 57 interruptions/100 administrations, 87.9% were unrelated to the medication task being observed. Intervention wards experienced a significant reduction in non-medication-related interruptions from 50/100 administrations (95% CI 45 to 55) to 34/100 (95% CI 30 to 38). Controlling for clustering, ward type and medication route showed a significant reduction of 15 non-medication-related interruptions/100 administrations compared with control wards. A total of 88 nurses (38.8%) completed the poststudy survey. Intervention ward nurses reported that vests were time consuming, cumbersome and hot. Only 48% indicated that they would support the intervention becoming hospital policy. Nurses experienced a high rate of interruptions. Few were related to the medication task, demonstrating considerable scope to reduce unnecessary interruptions. While the intervention was associated with a statistically significant decline in non-medication-related interruptions, the magnitude of this reduction and its likely impact on error rates should be considered, relative to the effectiveness of alternate interventions, associated costs, likely acceptability and long-term sustainability of such interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Traditions of research into interruptions in healthcare: A conceptual review.
McCurdie, Tara; Sanderson, Penelope; Aitken, Leanne M
2017-01-01
Researchers from diverse theoretical backgrounds have studied workplace interruptions in healthcare, leading to a complex and conflicting body of literature. Understanding pre-existing viewpoints may advance the field more effectively than attempts to remove bias from investigations. To identify research traditions that have motivated and guided interruptions research, and to note research questions posed, gaps in approach, and possible avenues for future research. A critical review was conducted of research on interruptions in healthcare. Two researchers identified core research communities based on the community's motivations, philosophical outlook, and methods. Among the characteristics used to categorise papers into research communities were the predominant motivation for studying interruptions, the research questions posed, and key contributions to the body of knowledge on interruptions in healthcare. In cases where a paper approached an equal number of characteristics from two traditions, it was placed in a blended research community. A total of 141 papers were identified and categorised; all papers identified were published from 1994 onwards. Four principal research communities emerged: epidemiology, quality improvement, cognitive systems engineering (CSE), and applied cognitive psychology. Blends and areas of mutual influence between the research communities were identified that combine the benefits of individual traditions, but there was a notable lack of blends incorporating quality improvement initiatives. The question most commonly posed by researchers across multiple communities was: what is the impact of interruptions? Impact was measured as a function of task time or risk in the epidemiology tradition, situation awareness in the CSE tradition, or resumption lag (time to resume an interrupted task) in the applied cognitive psychology tradition. No single question about interruptions in healthcare was shared by all four of the core communities. Much research on workplace interruptions in healthcare can be described in terms of fundamental values of four distinct research traditions and the communities that bring the values and methods: of those research traditions to their investigations. Blends between communities indicate that mutual influence has occurred as interruptions research has progressed. It is clear from this review that there is no single or privileged perspective to study interruptions. Instead, these findings suggest that researchers investigating interruptions in healthcare would benefit from being more aware of different perspectives from their own, especially when they consider workplace interventions to reduce interruptions. Copyright © 2016. Published by Elsevier Ltd.
Individual Differences in Working-Memory Capacity and Task Resumption Following Interruptions
ERIC Educational Resources Information Center
Foroughi, Cyrus K.; Werner, Nicole E.; McKendrick, Ryan; Cades, David M.; Boehm-Davis, Deborah A.
2016-01-01
Previous research has shown that there is a time cost (i.e., a resumption lag) associated with resuming a task following an interruption and that the longer the duration of the interruption, the greater the time cost (i.e., resumption lag increases as interruption duration increases). The memory-for-goals model (Altmann & Trafton, 2002)…
Assessing Individual-Level Impact of Interruptions during Online Testing
ERIC Educational Resources Information Center
Sinharay, Sandip; Wan, Ping; Choi, Seung W.; Kim, Dong-In
2015-01-01
With an increase in the number of online tests, the number of interruptions during testing due to unexpected technical issues seems to be on the rise. For example, interruptions occurred during several recent state tests. When interruptions occur, it is important to determine the extent of their impact on the examinees' scores. Researchers such as…
DC Interruption Characteristic on Vacuum Circuit Breaker
NASA Astrophysics Data System (ADS)
Odaka, Hiromi; Yamada, Masataka; Sakuma, Ryohei; Ding, Cuie; Kaneko, Eiji; Yanabu, Satoru
A high speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on a rate of change of the current (di/dt). As a fundamental research, we investigated the di/dt-dv/dt characteristics and the insulation recovery characteristic after interrupting the counter-pulse current for various contact materials of AgWC, CuW, and CuCr. The results revealed that the case where gap length is larger is better in a current interruption performance. Moreover, it was found that di/dt is not dependent on the insulation recovery characteristics, but the magnitude of interruption current influences greatly.
Expanded serial communication capability for the transport systems research vehicle laptop computers
NASA Technical Reports Server (NTRS)
Easley, Wesley C.
1991-01-01
A recent upgrade of the Transport Systems Research Vehicle (TSRV) operated by the Advanced Transport Operating Systems Program Office at the NASA Langley Research Center included installation of a number of Grid 1500 series laptop computers. Each unit is a 80386-based IBM PC clone. RS-232 data busses are needed for TSRV flight research programs, and it has been advantageous to extend the application of the Grids in this area. Use was made of the expansion features of the Grid internal bus to add a user programmable serial communication channel. Software to allow use of the Grid bus expansion has been written and placed in a Turbo C library for incorporation into applications programs in a transparent manner via function calls. Port setup; interrupt-driven, two-way data transfer; and software flow control are built into the library functions.
Sprawling nursery unveils propane backup for natural gas boilers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-02-01
First, take the most authoritative policy- making body in the pervasive problem area of Southern California air pollution (South Coast Air Quality Management District - SCAQMD). Then apply that organization's recently- enacted regulation prohibiting the use of diesel fuel in boilers to a well-known commercial establishment. The result is an alternative fuel story, that's too engaging to overlook. Monrovia Nursery, a 65-year-old, 500-acre wholesale growing facility in Azusa, Calif., has installed two 200-hp Dixon boilers, a 14 MMBtuh Sam Dick Industries vaporizer, and six 1150-gal. tanks on the property for the use of propane as a backup fuel. While themore » nursery ordinarily uses natural gas for water heating, there are times during the winter when the supply may be curtailed or interrupted. It is then that propane would be used to heat water to keep more than 1200 varieties of plants growing as they should.« less
Regioselective synthesis of C3 alkylated and arylated benzothiophenes
NASA Astrophysics Data System (ADS)
Shrives, Harry J.; Fernández-Salas, José A.; Hedtke, Christin; Pulis, Alexander P.; Procter, David J.
2017-03-01
Benzothiophenes are heterocyclic constituents of important molecules relevant to society, including those with the potential to meet modern medical challenges. The construction of molecules would be vastly more efficient if carbon-hydrogen bonds, found in all organic molecules, can be directly converted into carbon-carbon bonds. In the case of elaborating benzothiophenes, functionalization of carbon-hydrogen bonds at carbon-number 3 (C3) is markedly more demanding than at C2 due to issues of regioselectivity (C3 versus C2), and the requirement of high temperatures, precious metals and the installation of superfluous directing groups. Herein, we demonstrate that synthetically unexplored but readily accessible benzothiophene S-oxides serve as novel precursors for C3-functionalized benzothiophenes. Employing an interrupted Pummerer reaction to capture and then deliver phenol and silane coupling partners, we have discovered a directing group-free method that delivers C3-arylated and -alkylated benzothiophenes with complete regioselectivity, under metal-free and mild conditions.
Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state.
Baek, Hyun Jae; Lee, Haet Bit; Kim, Jung Soo; Choi, Jong Min; Kim, Ko Keun; Park, Kwang Suk
2009-03-01
Nonintrusive monitoring of a driver's physiological signals was introduced and evaluated in a car as a test of extending the concept of ubiquitous healthcare to vehicles. Electrocardiogram, photoplethysmogram, galvanic skin response, and respiration were measured in the ubiquitous healthcare car (U-car) using nonintrusively installed sensors on the steering wheel, driver's seat, and seat belt. Measured signals were transmitted to the embedded computer via Bluetooth(R) communication and processed. We collected and analyzed physiological signals during driving in order to estimate a driver's stress state while using this system. In order to compare the effect of stress on physical and mental conditions, two categories of stresses were defined. Experimental results show that a driver's physiological signals were measured with acceptable quality for analysis without interrupting driving, and they were changed meaningfully due to elicited stress. This nonintrusive monitoring can be used to evaluate a driver's state of health and stress.
Lightning prevention systems for paper mills
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carpenter, R.B. Jr.
1989-05-01
Paper mills are increasingly relying on sensitive electronic equipment to control their operations. However, the sensitivity of these devices has made mills vulnerable to the effects of lightning strokes. An interruption in the power supply or the destruction of delicate microcircuits can have devastating effects on mill productivity. The authors discuss how lightning strokes can be prevented by a Dissipation Array system (DAS). During the past 17 years, the concept has been applied to a host of applications in regions with a high incidence of lightning activity. With nearly 700 systems now installed, more than 4000 system-years of history havemore » been accumulated. Areas as large as 1 km{sup 2} and towers as high as 2000 ft have been protected and completely isolated from lightning strokes. There have been very few failures, and in every case, the cause of the failure was determined and corrected.« less
The Chronic Detrimental Impact of Interruptions in a Simulated Submarine Track Management Task.
Loft, Shayne; Sadler, Andreas; Braithwaite, Janelle; Huf, Samuel
2015-12-01
The objective of this article is to examine the extent to which interruptions negatively impact situation awareness and long-term performance in a submarine track management task where pre- and postinterruption display scenes remained essentially identical. Interruptions in command and control task environments can degrade performance well beyond the first postinterruption action typically measured for sequential static tasks, because individuals need to recover their situation awareness for multiple unfolding display events. Participants in the current study returned to an unchanged display scene following interruption and therefore could be more immune to such long-term performance deficits. The task required participants to monitor a display to detect contact heading changes and to make enemy engagement decisions. Situation awareness (Situation Present Assessment Method) and subjective workload (NASA-Task Load Index) were measured. The interruption replaced the display for 20 s with a blank screen, during which participants completed a classification task. Situation awareness after returning from interruption was degraded. Participants were slower to make correct engagement decisions and slower and less accurate in detecting heading changes, despite these task decisions being made at least 40 s following the interruption. Interruptions negatively impacted situation awareness and long-term performance because participants needed to redetermine the location and spatial relationship between the displayed contacts when returning from interruption, either because their situation awareness for the preinterruption scene decayed or because they did not encode the preinterruption scene. Interruption in work contexts such as submarines is unavoidable, and further understanding of how operators are affected is required to improve work design and training. © 2015, Human Factors and Ergonomics Society.
Landrian, Ivette; McFarland, Karen N; Liu, Jilin; Mulligan, Connie J; Rasmussen, Astrid; Ashizawa, Tetsuo
2017-01-01
Spinocerebellar ataxia type 10 (SCA10), an autosomal dominant cerebellar ataxia disorder, is caused by a non-coding ATTCT microsatellite repeat expansion in the ataxin 10 gene. In a subset of SCA10 families, the 5'-end of the repeat expansion contains a complex sequence of penta- and heptanucleotide interruption motifs which is followed by a pure tract of tandem ATCCT repeats of unknown length at its 3'-end. Intriguingly, expansions that carry these interruption motifs correlate with an epileptic seizure phenotype and are unstable despite the theory that interruptions are expected to stabilize expanded repeats. To examine the apparent contradiction of unstable, interruption-positive SCA10 expansion alleles and to determine whether the instability originates outside of the interrupted region, we sequenced approximately 1 kb of the 5'-end of SCA10 expansions using the ATCCT-PCR product in individuals across multiple generations from four SCA10 families. We found that the greatest instability within this region occurred in paternal transmissions of the allele in stretches of pure ATTCT motifs while the intervening interrupted sequences were stable. Overall, the ATCCT interruption changes by only one to three repeat units and therefore cannot account for the instability across the length of the disease allele. We conclude that the AT-rich interruptions locally stabilize the SCA10 expansion at the 5'-end but do not completely abolish instability across the entire span of the expansion. In addition, analysis of the interruption alleles across these families support a parsimonious single origin of the mutation with a shared distant ancestor.
ERIC Educational Resources Information Center
Mansi, Gary R.
2011-01-01
The modern workplace environment is filled with interruptions due to the necessity of coworkers to communicate with each other. Studies have revealed that interruptions can disrupt the ability of a knowledge worker to concentrate on a task, which can impact task performance (TP). Communication interruptions are due, in part, to the unavoidable…
Fiber optical cable and connector system (FOCCoS) for PFS/ Subaru
NASA Astrophysics Data System (ADS)
de Oliveira, Antonio Cesar; de Oliveira, Lígia Souza; de Arruda, Marcio V.; Souza Marrara, Lucas; dos Santos, Leandro H.; Ferreira, Décio; dos Santos, Jesulino B.; Rosa, Josimar A.; Junior, Orlando V.; Pereira, Jeferson M.; Castilho, Bruno; Gneiding, Clemens; Junior, Laerte S.; de Oliveira, Claudia M.; Gunn, James; Ueda, Akitoshi; Takato, Naruhisa; Shimono, Atsushi; Sugai, Hajime; Karoji, Hiroshi; Kimura, Masahiko; Tamura, Naoyuki; Wang, Shiang-Yu; Murray, Graham; Le Mignant, David; Madec, Fabrice; Jaquet, Marc; Vives, Sebastien; Fisher, Charlie; Braun, David; Schwochert, Mark; Reiley, Daniel J.
2014-07-01
FOCCoS, "Fiber Optical Cable and Connector System" has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition. All optical fibers from Cable C, protected by tubes, pass through the motors' bench plate, three modular plates and a strain relief box, terminating at the Tower Connector. Cable B is permanently installed at Subaru Telescope structure, as a link between Cable C and Cable A. This cable B starts at the Tower Connector device, placed on a lateral structure of the telescope, and terminates at the Gang Connector device. Cable B will be routed to minimize the compression, torsion and bending caused by the cable weight and telescope motion. In the spectrograph room, Cable A starts at the Gang Connector, crosses a distribution box and terminates in a slit device. Each slit device receives approximately 600 optical fibers, linearly arrayed in a curve for better orientation of the light to the spectrograph collimator mirror. Four sets of Gang Connectors, distribution boxes and Slit devices complete one Cable A. This paper will review the general design of the FOCCoS subsystem, methods used to manufacture the involved devices, and the needed tests results to evaluate the total efficiency of the set.
A study of pressure losses in residential air distribution systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abushakra, Bass; Walker, Iain S.; Sherman, Max H.
2002-07-01
An experimental study was conducted to evaluate the pressure drop characteristics of residential duct system components that are either not available or not thoroughly (sometimes incorrectly) described in existing duct design literature. The tests were designed to imitate cases normally found in typical residential and light commercial installations. The study included three different sizes of flexible ducts, under different compression configurations, splitter boxes, supply boots, and a fresh air intake hood. The experimental tests conformed to ASHRAE Standard 120P--''Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings''. The flexible duct study covered compressibility and bending effectsmore » on the total pressure drop, and the results showed that the available published references tend to underestimate the effects of compression in flexible ducts that can increase pressure drops by up to a factor of nine. The supply boots were tested under different configurations including a setup where a flexible duct elbow connection was considered as an integral part of the supply boot. The supply boots results showed that diffusers can increase the pressure drop by up to a factor of two in exit fittings, and the installation configuration can increase the pressure drop by up to a factor of five. The results showed that it is crucial for designers and contractors to be aware of the compressibility effects of the flexible duct, and the installation of supply boots and diffusers.« less
Performance upgrades in the EUV engineering test stand
NASA Astrophysics Data System (ADS)
Tichenor, Daniel A.; Replogle, William C.; Lee, Sang Hun; Ballard, William P.; Leung, Alvin H.; Kubiak, Glenn D.; Klebanoff, Leonard E.; Graham, Samual, Jr.; Goldsmith, John E. M.; Jefferson, Karen L.; Wronosky, John B.; Smith, Tony G.; Johnson, Terry A.; Shields, Harry; Hale, Layton C.; Chapman, Henry N.; Taylor, John S.; Sweeney, Donald W.; Folta, James A.; Sommargren, Gary E.; Goldberg, Kenneth A.; Naulleau, Patrick P.; Attwood, David T., Jr.; Gullikson, Eric M.
2002-07-01
The EUV Engineering Test Stand (ETS) has demonstrated the printing of 100-nm-resolution scanned images. This milestone was first achieved while the ETS operated in an initial configuration using a low power laser and a developmental projection system, PO Box 1. The drive laser has ben upgraded to a single chain of the three-chain Nd:YAG laser developed by TRW. The result in exposure time is approximately 4 seconds for static exposures. One hundred nanometer dense features have been printed in step-and-scan operation with the same image quality obtained in static printing. These experiments are the first steps toward achieving operation using all three laser chains for a total drive laser power of 1500 watts. In a second major upgrade the developmental wafer stage platen, used to demonstrate initial full-field imaging, has been replaced with the final low-expansion platen made of Zerodur. Additional improvements in the hardware and control software have demonstrated combined x and jitter from 2 to 4 nm RMS Over most of the wafer stage travel range, while scanning at the design scan speed of 10 mm/s at the wafer. This value, less than half of the originally specified jitter, provides sufficient stability to support printing of 70 nm features as planned, when the upgraded projection system is installed. The third major upgrade will replace PO Box 1 with an improved projection system, PO Box 2, having lower figure error and lower flare. In addition to these upgrades, dose sensors at the reticle and wafer planes and an EUV- sensitive aerial image monitor have been integrated into the ETS. This paper reports on ETS system upgrades and the impact on system performance.
An experimental test on time constraint and sexual conflict over parental care.
Griggio, Matteo
2015-09-01
Because parental care is costly, a sexual conflict between parents over parental investment is expected to arise. Parental care behavior is an adaptive decision, involving trade-offs between remating, and consequently desertion of the brood, and continuing parental effort. If the main advantage of desertion is remating, then this will be a time constraint, because the deserting individual will require a certain minimum period of time to breed again in the same breeding season. So, a short breeding season should force certain individuals to desert the first brood to have enough time to successfully complete their second breeding attempt. The rock sparrow, Petronia petronia, is an unusual species in which brood desertion can occur in both sexes and the breeding season is quite short so it is a good species to investigate the role of time constraint on brood desertion. For 3 years, I investigated the brood desertion modality of the rock sparrow. Then, for 2 years, I removed a group of experimental nest boxes during the autumn. Later, I re-installed the experimental nest boxes after the start of the breeding season (2 weeks after the first egg was laid), mimicking a shortening of the breeding season for the (experimental) pairs that used experimental nest boxes. I found that in the experimental pairs, the percentage of deserting individuals was significantly higher than in the control groups, and the deserting individuals were older females. This experiment adds to our knowledge of timing of reproduction effects on individual decisions to desert by showing that a short and delayed breeding season may have different effects on males and females. To my knowledge, this is the first experimental study that demonstrates a direct link between time constraint and brood desertion.
An experimental test on time constraint and sexual conflict over parental care
Griggio, Matteo
2015-01-01
Because parental care is costly, a sexual conflict between parents over parental investment is expected to arise. Parental care behavior is an adaptive decision, involving trade-offs between remating, and consequently desertion of the brood, and continuing parental effort. If the main advantage of desertion is remating, then this will be a time constraint, because the deserting individual will require a certain minimum period of time to breed again in the same breeding season. So, a short breeding season should force certain individuals to desert the first brood to have enough time to successfully complete their second breeding attempt. The rock sparrow, Petronia petronia, is an unusual species in which brood desertion can occur in both sexes and the breeding season is quite short so it is a good species to investigate the role of time constraint on brood desertion. For 3 years, I investigated the brood desertion modality of the rock sparrow. Then, for 2 years, I removed a group of experimental nest boxes during the autumn. Later, I re-installed the experimental nest boxes after the start of the breeding season (2 weeks after the first egg was laid), mimicking a shortening of the breeding season for the (experimental) pairs that used experimental nest boxes. I found that in the experimental pairs, the percentage of deserting individuals was significantly higher than in the control groups, and the deserting individuals were older females. This experiment adds to our knowledge of timing of reproduction effects on individual decisions to desert by showing that a short and delayed breeding season may have different effects on males and females. To my knowledge, this is the first experimental study that demonstrates a direct link between time constraint and brood desertion. PMID:26380691
Surveying DNA Elements within Functional Genes of Heterocyst-Forming Cyanobacteria
Hilton, Jason A.; Meeks, John C.; Zehr, Jonathan P.
2016-01-01
Some cyanobacteria are capable of differentiating a variety of cell types in response to environmental factors. For instance, in low nitrogen conditions, some cyanobacteria form heterocysts, which are specialized for N2 fixation. Many heterocyst-forming cyanobacteria have DNA elements interrupting key N2 fixation genes, elements that are excised during heterocyst differentiation. While the mechanism for the excision of the element has been well-studied, many questions remain regarding the introduction of the elements into the cyanobacterial lineage and whether they have been retained ever since or have been lost and reintroduced. To examine the evolutionary relationships and possible function of DNA sequences that interrupt genes of heterocyst-forming cyanobacteria, we identified and compared 101 interruption element sequences within genes from 38 heterocyst-forming cyanobacterial genomes. The interruption element lengths ranged from about 1 kb (the minimum able to encode the recombinase responsible for element excision), up to nearly 1 Mb. The recombinase gene sequences served as genetic markers that were common across the interruption elements and were used to track element evolution. Elements were found that interrupted 22 different orthologs, only five of which had been previously observed to be interrupted by an element. Most of the newly identified interrupted orthologs encode proteins that have been shown to have heterocyst-specific activity. However, the presence of interruption elements within genes with no known role in N2 fixation, as well as in three non-heterocyst-forming cyanobacteria, indicates that the processes that trigger the excision of elements may not be limited to heterocyst development or that the elements move randomly within genomes. This comprehensive analysis provides the framework to study the history and behavior of these unique sequences, and offers new insight regarding the frequency and persistence of interruption elements in heterocyst-forming cyanobacteria. PMID:27206019
Surveying DNA Elements within Functional Genes of Heterocyst-Forming Cyanobacteria.
Hilton, Jason A; Meeks, John C; Zehr, Jonathan P
2016-01-01
Some cyanobacteria are capable of differentiating a variety of cell types in response to environmental factors. For instance, in low nitrogen conditions, some cyanobacteria form heterocysts, which are specialized for N2 fixation. Many heterocyst-forming cyanobacteria have DNA elements interrupting key N2 fixation genes, elements that are excised during heterocyst differentiation. While the mechanism for the excision of the element has been well-studied, many questions remain regarding the introduction of the elements into the cyanobacterial lineage and whether they have been retained ever since or have been lost and reintroduced. To examine the evolutionary relationships and possible function of DNA sequences that interrupt genes of heterocyst-forming cyanobacteria, we identified and compared 101 interruption element sequences within genes from 38 heterocyst-forming cyanobacterial genomes. The interruption element lengths ranged from about 1 kb (the minimum able to encode the recombinase responsible for element excision), up to nearly 1 Mb. The recombinase gene sequences served as genetic markers that were common across the interruption elements and were used to track element evolution. Elements were found that interrupted 22 different orthologs, only five of which had been previously observed to be interrupted by an element. Most of the newly identified interrupted orthologs encode proteins that have been shown to have heterocyst-specific activity. However, the presence of interruption elements within genes with no known role in N2 fixation, as well as in three non-heterocyst-forming cyanobacteria, indicates that the processes that trigger the excision of elements may not be limited to heterocyst development or that the elements move randomly within genomes. This comprehensive analysis provides the framework to study the history and behavior of these unique sequences, and offers new insight regarding the frequency and persistence of interruption elements in heterocyst-forming cyanobacteria.
Fang, B L; Qian, S Y; Jia, X L; Li, Z; Liu, J
2016-09-01
To analyze the interruptions of enteral nutrition (EN) and it's relationship to prognosis in children with sepsis in pediatric intensive care unit (PICU). Daily EN intake and reasons for EN interruptions were prospectively observed and recorded in children with sepsis who were admitted to our PICU from November 2012 to April 2013. Clinical prognosis was compared between children with and without EN interruptions by t, rank-sum and χ(2) tests. Totally 60 consecutive children were included, 42 males, median age 9.67 (5.36, 37.0) months; 50 children suffered from EN interruptions, while 10 children did not. Median time to EN initiation was 2.59 (1.53, 3.67) h; EN was interrupted in 83% (50/60) of children, for a total of 108 times and 696 h, the most common reasons were fibrobronchoscopy and radiologic procedures, 27 and 29 times respectively. Children spent 0.04 (0.02, 0.08) of their total observation period without EN nutrition due to EN interruptions, and was not correlated with pediatric critically ill score (r=0.12, P=0.38). Children with EN interruptions suffered from longer PICU duration ((12±7) vs. (7±4) d, t=2.18, P=0.03), but there was no significant difference in the 28(th) hospital day's mortality between these two groups (6 cases vs. 1 case, χ(2)=0.00, P=1.00). EN is frequently interrupted due to procedures needed fasting, EN intolerance and other reasons in children with sepsis. EN interruptions may have something to do with prolonged PICU length of stay, but the relationship needs to be examined in future studies.
Lithium Battery Transient Response as a Diagnostic Tool
NASA Astrophysics Data System (ADS)
Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.
2018-05-01
Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.
Parenting Outside the Box, Part Three: The New “Normal” | Poster
Editor’s Note: This article is the final installment in a series describing one NCI at Frederick parent’s perspective on special needs parenting. Part one can be found here, and part two can be found here. Parents of special-needs children do their best to help their kids thrive in typical society, but at times this can be challenging. For instance, I want my son, Harrison, to be able to participate in as many activities as he would like—but this can involve more than just signing him up and paying the registration fee. Fortunately, with a flexible approach and some simple tools, we have found that Harrison can still enjoy “normal” activities. Sometimes, all it takes is an honest conversation.
NASA Astrophysics Data System (ADS)
Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.
2017-12-01
The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.
Astronaut Shane Kimbrough Visits Marshall Space Flight Center
2017-08-31
NASA astronaut Shane Kimbrough presents highlights from his Expedition 49-50 mission aboard the International Space Station Sept. 19 to students from theU.S. Space & Rocket Center's Space Camp and team members at NASA's Marshall Space Flight Center. While serving as commander of the station, Kimbrough conducted four spacewalks, during which he installed new batteries and relay boxes, and helped move a pressurized mating adapter for future commercial crew spacecraft visiting the outpost. He also contributed to hundreds of experiments in biology, biotechnology, physical science and Earthobservations. One of these experiments was the Microgravity Expanded Stem Cells investigation, results of which could lead to the treatment of diseases andinjury in space and provide a way to improve stem cell production for medical therapies on Earth.
Johnson, Maree; Weidemann, Gabrielle; Adams, Rebecca; Manias, Elizabeth; Levett-Jones, Tracy; Aguilar, Vicki; Everett, Bronwyn
The aim of this qualitative study was to examine the nature of interruptions during medication administration. Focus groups were conducted with medical/surgical nurses (n = 15), critical care nurses (n = 13), and nurse managers/educators/specialists (n = 6). Most interruptions (78%) were predictable. Nurse-adopted strategies included blocking, engaging, mediating, multitasking, and preventing. Educational content was developed that relates behavioral strategies to respond to predictable and unpredictable interruptions.
Design and Integration of an Actuated Nose Strake Control System
NASA Technical Reports Server (NTRS)
Flick, Bradley C.; Thomson, Michael P.; Regenie, Victoria A.; Wichman, Keith D.; Pahle, Joseph W.; Earls, Michael R.
1996-01-01
Aircraft flight characteristics at high angles of attack can be improved by controlling vortices shed from the nose. These characteristics have been investigated with the integration of the actuated nose strakes for enhanced rolling (ANSER) control system into the NASA F-18 High Alpha Research Vehicle. Several hardware and software systems were developed to enable performance of the research goals. A strake interface box was developed to perform actuator control and failure detection outside the flight control computer. A three-mode ANSER control law was developed and installed in the Research Flight Control System. The thrust-vectoring mode does not command the strakes. The strakes and thrust-vectoring mode uses a combination of thrust vectoring and strakes for lateral- directional control, and strake mode uses strakes only for lateral-directional control. The system was integrated and tested in the Dryden Flight Research Center (DFRC) simulation for testing before installation in the aircraft. Performance of the ANSER system was monitored in real time during the 89-flight ANSER flight test program in the DFRC Mission Control Center. One discrepancy resulted in a set of research data not being obtained. The experiment was otherwise considered a success with the majority of the research objectives being met.
NASA Hardware Heads to Kennedy For Flight Preparations
2018-01-24
The Orion stage adapter will be part of the first integrated flight of NASA's heavy-lift rocket, the Space Launch System, and the Orion spacecraft. The adapter, approximately 5 feet tall and 18 feet in diameter, was designed and built at NASA's Marshall Space Flight Center in Huntsville, Alabama, with advanced friction stir welding technology. It will connect the SLS interim cryogenic propulsion stage to Orion on the first flight that will help engineers check out and verify the agency's new deep-space exploration systems. Inside the adapter, engineers installed special brackets and cabling for the 13 CubeSats that will fly as secondary payloads. The Cubesats are boot-box-sized science and technology investigations that will help pave the way for future human exploration in deep space. The Orion stage adapter flight article recently finished major testing of the avionics system that will deploy the CubeSats. Technicians at NASA's Kennedy Space Center, Florida, will install the secondary payloads and engineers will examine the hardware before it is stacked on the interim cryogenic propulsion stage in the Vehicle Assembly Building prior to launch. For more information about SLS hardware, visit nasa.gov/sls.
NASA Astrophysics Data System (ADS)
Hut, R.
2017-12-01
When desiging prototype sensors for environmental variables a critical step is a comparison campaign where the new sensor is compared to current state of the art sensors. In this step one of the headaches for researchers can be connecting their sensor to a logging or communication device. I present a simple solution: to use smartphone that scans for Bluetooth Low Energy transmissions and uploads any measurement to a data server. In this way the prototype sensor only has to transmit its measurement values over BLE, which can be done using off-the-shelf components. The sensors don't have to be physically connected to the phone, allowing for very rapid deployment of sensors in locations that have a communication hub (ie. phone) installed. The communication and logging hub consists of nothing more than a low cost Android smartphone running a dedicated app. The phone is encased in a waterproof box with a large powerbank and a solar panel. I will demonstrate this live at the Fall Meeting. By installing these phones along permanent WMO certified station locations, comparisons campaigns can use the "golden standard" from the WMO without much problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dux, Joachim; Friedrich, Daniel; Lutz, Werner
2013-07-01
Decommissioning and dismantling of the former German Pilot Reprocessing Plant Karlsruhe (WAK) including the Vitrification Facility (VEK) is being executed in different Project steps related to the reprocessing, HLLW storage and vitrification complexes /1/. While inside the reprocessing building the total inventory of process equipment has already been dismantled and disposed of, the HLLW storage and vitrification complex has been placed out of operation since vitrification and tank rinsing procedures where finalized in year 2010. This paper describes the progress made in dismantling of the shielded boxes of the highly contaminated laboratory as a precondition to get access to themore » hot cells of the HLLW storage. The major challenges of the dismantling of this laboratory were the high dose rates up to 700 mSv/h and the locking technology for the removal of the hot cell installations. In parallel extensive prototype testing of different carrier systems and power manipulators to be applied to dismantle the HLLW-tanks and other hot cell equipment is ongoing. First experiences with the new manipulator carrier system and a new master slave manipulator with force reflection will be reported. (authors)« less
Cryogenic system configuration for the International Linear Collider (ILC) at mountainous site
NASA Astrophysics Data System (ADS)
Nakai, H.; Okamura, T.; Delikaris, D.; Peterson, T.; Yamamoto, A.
2017-02-01
The International Linear Collider (ILC) plans to make use of ten cryoplants for its main linacs, each providing 19 kW at 4.5 K equivalent and among of it 3.6 kW at 2 K. Each cryoplant will consist of various cryogenic components such as a 4.5 K refrigerator cold box, a 2 K refrigerator cold box, and helium compressors and so on. In the technical design report (TDR) of the ILC, due to the mountainous topology, almost all cryogenic components would be installed in underground cryogenic caverns next to the main linac tunnels and only cooling towers on surface area. However, we would like to find a more effective and sophisticated configuration of the cryoplant components (cryogenic configuration). Under several constraints of technical, geographical, and environmental points of view, the cryogenic configuration should be considered carefully to satisfy such various conditions. After discussions on this topic conducted at various workshops and conferences, an updated cryogenic configuration is suggested. The proposed updated configuration may affect the total construction cost of the ILC and the entire structure of the ILC conventional facilities. The updated cryogenic configuration is presented and the on-going discussions with the conventional facilities and siting (CFS) colleagues for further improvement of the cryogenic configuration is introduced.
Cryogenic thermometry for refrigerant distribution system of JT-60SA
NASA Astrophysics Data System (ADS)
Natsume, K.; Murakami, H.; Kizu, K.; Yoshida, K.; Koide, Y.
2015-12-01
JT-60SA is a fully superconducting fusion experimental device involving Japan and Europe. The cryogenic system supplies supercritical or gaseous helium to superconducting coils through valve boxes or coil terminal boxes and in-cryostat pipes. There are 86 temperature measurement points at 4 K along the distribution line. Resistance temperature sensors will be installed on cooling pipes in vacuum. In this work, two sensor attachment methods, two types of sensor, two thermal anchoring methods, and two sensor fixation materials have been experimentally evaluated in terms of accuracy and mass productivity. Finally, the verification test of thermometry has been conducted using the sample pipe fabricated in the same way to the production version, which has been decided by the comparison experiments. The TVO sensor is attached by the saddle method with Apiezon N grease and the measurement wires made of phosphor bronze are wound on the pipe with Stycast 2850FT as the thermal anchoring. A Cernox sensor is directly immersed in liquid helium as a reference thermometer during the experiment. The measured temperature difference between the attached one and reference one has been within ±15 mK in the range of 3.40-4.73 K. It has satisfies the accuracy requirement of 0.1 K.
Apparatus for and method of testing an electrical ground fault circuit interrupt device
Andrews, L.B.
1998-08-18
An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined. 17 figs.
Apparatus for and method of testing an electrical ground fault circuit interrupt device
Andrews, Lowell B.
1998-01-01
An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined.
Fast interrupt platform for extended DOS
NASA Technical Reports Server (NTRS)
Duryea, T. W.
1995-01-01
Extended DOS offers the unique combination of a simple operating system which allows direct access to the interrupt tables, 32 bit protected mode access to 4096 MByte address space, and the use of industry standard C compilers. The drawback is that fast interrupt handling requires both 32 bit and 16 bit versions of each real-time process interrupt handler to avoid mode switches on the interrupts. A set of tools has been developed which automates the process of transforming the output of a standard 32 bit C compiler to 16 bit interrupt code which directly handles the real mode interrupts. The entire process compiles one set of source code via a make file, which boosts productivity by making the management of the compile-link cycle very simple. The software components are in the form of classes written mostly in C. A foreground process written as a conventional application which can use the standard C libraries can communicate with the background real-time classes via a message passing mechanism. The platform thus enables the integration of high performance real-time processing into a conventional application framework.
Demonstration program for Omega receiver prototype microcomputer data processing
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1976-01-01
The JOLT (TM) commercial microcomputer, based on the MOS Technology 6502 processor chip, for use in Omega navigation system is evaluated. A computer program was prepared in hand-assembled code to demonstrate receiver operation. The processor provides binary processing with interrupts enabled, a carriage return is given to initialize the teleprinter, and a jump is performed to enter the program loop to wait for an interrupt. The program loop operates continuously testing the interrupt flag. The interrupt routine reads the receiver status word and determines whether the current time-slot is the A slot. If so, the interrupt flag, which is also the data index pointer, is reset to zero. The status word is stored in the status buffer. If the time-slot is not A, the interrupt flag/pointer is incremented by one to index the phase and status to the proper buffer words for later use by the print routine.
Effect of current vehicle’s interruption on traffic stability in cooperative car-following theory
NASA Astrophysics Data System (ADS)
Zhang, Geng; Liu, Hui
2017-12-01
To reveal the impact of the current vehicle’s interruption information on traffic flow, a new car-following model with consideration of the current vehicle’s interruption is proposed and the influence of the current vehicle’s interruption on traffic stability is investigated through theoretical analysis and numerical simulation. By linear analysis, the linear stability condition of the new model is obtained and the negative influence of the current vehicle’s interruption on traffic stability is shown in the headway-sensitivity space. Through nonlinear analysis, the modified Korteweg-de Vries (mKdV) equation of the new model near the critical point is derived and it can be used to describe the propagating behavior of the traffic density wave. Finally, numerical simulation confirms the analytical results, which shows that the current vehicle’s interruption information can destabilize traffic flow and should be considered in real traffic.
Huckels-Baumgart, Saskia; Baumgart, André; Buschmann, Ute; Schüpfer, Guido; Manser, Tanja
2016-12-21
Interruptions and errors during the medication process are common, but published literature shows no evidence supporting whether separate medication rooms are an effective single intervention in reducing interruptions and errors during medication preparation in hospitals. We tested the hypothesis that the rate of interruptions and reported medication errors would decrease as a result of the introduction of separate medication rooms. Our aim was to evaluate the effect of separate medication rooms on interruptions during medication preparation and on self-reported medication error rates. We performed a preintervention and postintervention study using direct structured observation of nurses during medication preparation and daily structured medication error self-reporting of nurses by questionnaires in 2 wards at a major teaching hospital in Switzerland. A volunteer sample of 42 nurses was observed preparing 1498 medications for 366 patients over 17 hours preintervention and postintervention on both wards. During 122 days, nurses completed 694 reporting sheets containing 208 medication errors. After the introduction of the separate medication room, the mean interruption rate decreased significantly from 51.8 to 30 interruptions per hour (P < 0.01), and the interruption-free preparation time increased significantly from 1.4 to 2.5 minutes (P < 0.05). Overall, the mean medication error rate per day was also significantly reduced after implementation of the separate medication room from 1.3 to 0.9 errors per day (P < 0.05). The present study showed the positive effect of a hospital-based intervention; after the introduction of the separate medication room, the interruption and medication error rates decreased significantly.
Raunsø, Jakob; Selmer, Christian; Olesen, Jonas Bjerring; Charlot, Mette Gitz; Olsen, Anne-Marie S; Bretler, Ditte-Marie; Nielsen, Jørn Dalsgaard; Dominguez, Helena; Gadsbøll, Niels; Køber, Lars; Gislason, Gunnar H; Torp-Pedersen, Christian; Hansen, Morten Lock
2012-08-01
It is presently unknown whether patients with atrial fibrillation (AF) are at increased risk of thrombo-embolic adverse events after interruption of warfarin treatment. The purpose of this study was to assess the risk and timing of thrombo-embolism after warfarin treatment interruption. A retrospective, nationwide cohort study of all patients in Denmark treated with warfarin after a first hospitalization with AF in the period 1997-2008. Incidence rate ratios (IRRs) of thrombo-embolic events and all-cause mortality were calculated using the Poisson regression analyses. In total, 48 989 AF patients receiving warfarin treatment were included. Of these, 35 396 patients had at least one episode of warfarin treatment interruption. In all, 8255 deaths or thrombo-embolic events occurred during treatment interruption showing an initial clustering of events with 2717, 835, 500, and 427 events occurring during 0-90, 91-180, 181-270, and 271-360 days after treatment interruption, respectively. Correspondingly, the crude incidence rates were 31.6, 17.7, 12.3, and 11.4 events per 100 patient-years. In a multivariable analysis, the first 90-day interval of treatment interruption was associated with a markedly higher risk of death or thrombo-embolism (IRR 2.5; 95% confidence interval 2.3-2.8) vs. the interval of 271-360 days. In patients with AF, an interruption of warfarin treatment is associated with a significantly increased short-term risk of death or thrombo-embolic events within the first 90 days of treatment interruption.
Sex Differences in Children's Conversation.
ERIC Educational Resources Information Center
Esposito, Anita
1979-01-01
The recorded conversations of 40 preschool children in small groups were analyzed for interruptions, overlaps, lapses, and gaps. Significant differences were found between heterogeneous and homogeneous groups for interruptions, with boys interrupting girls at a two to one ratio. (Author/RL)
How to Interrupt Oppressive Behavior.
ERIC Educational Resources Information Center
McClintock, Mary
1990-01-01
Describes continuum of responses to examples of race-, handicap-, and sex discrimination by participants and staff of camping programs. Recommends following actions toward social justice: educating oneself; interrupting negative behavior; interrupting and educating; supporting proactive response; and initiating proactive response. Includes…
Reducing the Disruptive Effects of Interruptions With Noninvasive Brain Stimulation.
Blumberg, Eric J; Foroughi, Cyrus K; Scheldrup, Melissa R; Peterson, Matthew S; Boehm-Davis, Debbie A; Parasuraman, Raja
2015-09-01
The authors determine whether transcranial direct current stimulation (tDCS) can reduce resumption time when an ongoing task is interrupted. Interruptions are common and disruptive. Working memory capacity has been shown to predict resumption lag (i.e., time to successfully resume a task after interruption). Given that tDCS applied to brain areas associated with working memory can enhance performance, tDCS has the potential to improve resumption lag when a task is interrupted. Participants were randomly assigned to one of four groups that received anodal (active) stimulation of 2 mA tDCS to one of two target brain regions, left and right dorsolateral prefrontal cortex (DLPFC), or to one of two control areas, active stimulation of the left primary motor cortex or sham stimulation of the right DLPFC, while completing a financial management task that was intermittently interrupted with math problem solving. Anodal stimulation to the right and left DLPFC significantly reduced resumption lags compared to the control conditions (sham and left motor cortex stimulation). Additionally, there was no speed-accuracy tradeoff (i.e., the improvement in resumption time was not accompanied by an increased error rate). Noninvasive brain stimulation can significantly decrease resumption lag (improve performance) after a task is interrupted. Noninvasive brain stimulation offers an easy-to-apply tool that can significantly improve interrupted task performance. © 2014, Human Factors and Ergonomics Society.
Implementation of civionics in a second generation steel-free bridge deck
NASA Astrophysics Data System (ADS)
Klowak, Chad; Rivera, Evangeline; Mufti, Aftab
2005-05-01
As the design and construction of civil structures continue to evolve, it is becoming imperative that these structures be monitored for their health. In order to meet this need, the discipline of Civionics has emerged. Civionics is a new term coined from Civil-Electronics, which is derived from the application of electronics to civil structures. It is similar to the term Avionics, which is used in the aerospace industry. If structural health monitoring is to become part of civil structural engineering, it should include Civionics. It involves the application of electronics to civil structures and aims to assist engineers in realizing the full benefits of structural health monitoring (SHM). In past SHM field applications, the main reason for the failure of a sensor was not the installation of the sensor itself but the egress of the sensor cables. Often, the cables were not handled and protected correctly. For SHM to be successful, specifications must be written on the entire process, beginning with system design and concluding with data collection, interpretation, and management. Civionics specifications include the technical requirements for a SHM system which encompasses fibre optic sensors, cables, conduits, junction boxes and the control room. A specification for data collection and storage is currently being developed as well. In the spring of 2004 research engineers at the University of Manitoba constructed a full-scale second generation steel free bridge deck. The bridge deck is the first of its kind to fully incorporate a complete civionics structural health monitoring system to monitor the deck's behaviour during destructive testing. Throughout the construction of the bridge deck, the entire installation of the civionics system was carried out by research engineers simulating an actual implementation of such a system in a large scale construction environment. One major concern that consulting engineers have raised is the impact that a civionics system that uses conduit, junction boxes, and other electrical ancillary protection, will have when embedded and installed externally on full-scale infrastructure. The full-scale destructive testing of a second generation steel-free bridge deck using a civionics system designed and implemented following guidelines in a civioncs specification manual at the University of Manitoba will provide engineers with the information necessary to address the constructability and structural integrity issues. Civioncs combined with structural health monitoring will provide engineers with feedback necessary to aid in optimizing design techniques and understanding our infrastructures performance, behaviour and state of condition.
Yazdanpanah, Yazdan; Wolf, Lindsey L; Anglaret, Xavier; Gabillard, Delphine; Walensky, Rochelle P; Moh, Raoul; Danel, Christine; Sloan, Caroline E; Losina, Elena; Freedberg, Kenneth A
2010-01-01
International trials have shown that CD4+ T-cell-guided structured treatment interruptions (STI) of antiretroviral therapy (ART) lead to worse outcomes than continuous treatment. We simulated continuous ART and STI strategies with higher CD4+ T-cell interruption/reintroduction thresholds than those assessed in actual trials. Using a model of HIV, we simulated cohorts of African adults with different baseline CD4+ T-cell counts (< or = 200; 201-350; and 351-500 cells/microl). We varied ART initiation criteria (immediate; CD4+ T-cell count < 350 cells/microl or > or = 350 cells/microl with severe HIV-related disease; and CD4+ T-cell count <200 cells/microl or > or = 200 cells/microl with severe HIV-related disease), and ART interruption/reintroduction thresholds (350/250; 500/350; and 700/500 cells/microl). First-line therapy was non-nucleoside reverse transcriptase inhibitor (NNRTI)-based and second-line therapy was protease inhibitor (PI)-based. STI generally reduced life expectancy compared with continuous ART. Life expectancy increased with earlier ART initiation and higher interruption/reintroduction thresholds. STI reduced life expectancy by 48-69 and 11-30 months compared with continuous ART when interruption/reintroduction thresholds were 350/250 and 500/350 cells/microl, depending on ART initiation criteria. When patients interrupted/reintroduced ART at 700/500 cells/microl, life expectancies ranged from 2 months lower to 1 month higher than continuous ART. STI-related life expectancy increased with decreased risk of virological resistance after ART interruptions. STI with NNRTI-based regimens was almost always less effective than continuous treatment, regardless of interruption/reintroduction thresholds. The risks associated with STI decrease only if patients start ART earlier, interrupt/reintroduce treatment at very high CD4+ T-cell thresholds (700/500 cells/microl) and use first-line medications with higher resistance barriers, such as PIs.
Weigl, Matthias; Antoniadis, Sophia; Chiapponi, Costanza; Bruns, Christiane; Sevdalis, Nick
2015-01-01
Surgeons' intra-operative workload is critical for effective and safe surgical performance. Detrimental conditions in the operating room (OR) environment may add to perceived workload and jeopardize surgical performance and outcomes. This study aims to evaluate the impact of different intra-operative workflow interruptions on surgeons' capacity to manage their workload safely and efficiently. This was an observational study of intra-operative interruptions and self-rated workload in two surgical specialties (general, orthopedic/trauma surgery). Intra-operative interruptions were assessed via expert observation using a well-validated observation tool. Surgeons, nurses, and anesthesiologists assessed their intra-operative workload directly after case completion based on three items of the validated Surgery Task Load Index (mental demand, situational stress, distraction). A total of 56 elective cases (35 open, 21 laparoscopic) with 94 workload ratings were included. Mean intra-operative duration was 1 h 37 min. Intra-operative interruptions were on average observed 9.78 times per hour. People who entered/exited the OR (30.6 %) as well as telephone-/beeper-related disruptions (23.6 %) occurred most often. Equipment and OR environment-related interruptions were associated with highest interference with team functioning particularly in laparoscopic procedures. After identifying task and procedural influences, partial correlational analyses revealed that case-irrelevant communications were negatively associated with surgeons' mental fatigue and situational stress, whereas surgeons' reported distraction was increased by case-irrelevant communication and procedural disruptions. OR nurses' and anesthesiologists' perceived workload was also related to intra-operative interruption events. Our study documents the unique contribution of different interruptions on surgeons' workload; whereas case-irrelevant communications may be beneficial for mental fatigue and stress in routine cases, procedural interruptions and case-irrelevant communication may contribute to surgeons' mental focus deteriorating. Well-designed OR environments, surgical leadership, and awareness can help to control unnecessary interruptions for effective and safe surgical care.
Global interrupt and barrier networks
Blumrich, Matthias A.; Chen, Dong; Coteus, Paul W.; Gara, Alan G.; Giampapa, Mark E; Heidelberger, Philip; Kopcsay, Gerard V.; Steinmacher-Burow, Burkhard D.; Takken, Todd E.
2008-10-28
A system and method for generating global asynchronous signals in a computing structure. Particularly, a global interrupt and barrier network is implemented that implements logic for generating global interrupt and barrier signals for controlling global asynchronous operations performed by processing elements at selected processing nodes of a computing structure in accordance with a processing algorithm; and includes the physical interconnecting of the processing nodes for communicating the global interrupt and barrier signals to the elements via low-latency paths. The global asynchronous signals respectively initiate interrupt and barrier operations at the processing nodes at times selected for optimizing performance of the processing algorithms. In one embodiment, the global interrupt and barrier network is implemented in a scalable, massively parallel supercomputing device structure comprising a plurality of processing nodes interconnected by multiple independent networks, with each node including one or more processing elements for performing computation or communication activity as required when performing parallel algorithm operations. One multiple independent network includes a global tree network for enabling high-speed global tree communications among global tree network nodes or sub-trees thereof. The global interrupt and barrier network may operate in parallel with the global tree network for providing global asynchronous sideband signals.
Bower, Rachel A; Coad, Jane E; Manning, Joseph C; Pengelly, Theresa A
2018-02-01
In the paediatric intensive care unit (PICU), medication administration is challenging. Empirical studies demonstrate that interruptions occur frequently and that nurses are fundamental in the delivery of medication. However, little is known about nurse's decision making when interrupted during medication administration. Therefore, the objective is to understand decision making when interrupted during medication administration within the PICU. A qualitative study incorporating non-participant observation and audio recorded semi-structured interviews. A convenience sample of ten PICU nurses were interviewed. Each interview schedule was informed by two hours of observation which involved a further 29 PICU nurses. Data was analysed using Framework Analysis. A regional PICU located in a university teaching hospital in the United Kingdom. Analysis resulted in four overarching themes: (1) Guiding the medication process, (2) Concentration, focus and awareness, (3) Influences on interruptions (4) Impact and recovery CONCLUSION: Medication administration within the PICU is an essential but complex activity. Interruptions can impact on focus and concentration which can contribute to patient harm. Decision making by PICU nurses is influenced by interruption awareness, fluctuating levels of concentration, and responding to critically ill patient and families' needs. Copyright © 2017 Elsevier Ltd. All rights reserved.
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
1984-06-01
UNSOLINTERRUPT: ; Dismiss unsolicited Interrupt. POPR M<RI,RI,R2,R3,R4,R5> ; Restore RZ-R5 REI ; Return from interrupt. .SBTTL AVCANCEL. Cancel I/O routine...Dismiss unsolicited Interrupt. POPR M<R8,RI.R2,R3,R4,R5> ; Restore RN-R5 REI ; Return from interrupt. .SBTTL ODCANCEL, Cancel I/0 routine ++ I ODCANCEL...output buffer. ODREGDU4P: i Dump device registers MOVZBL ODNUMREGS,(Rg)+ i Store device register count. NOVZWL UCBSWODBYTCNT(RS),- aStore BYTE count
Xu, Tingting; Zhou, Cong-Zhao; Xiao, Jianxi; Liu, Jinsong
2018-02-20
Naturally occurring interruptions in nonfibrillar collagen play key roles in molecular flexibility, collagen degradation, and ligand binding. The structural feature of the interruption sequences and the molecular basis for their functions have not been well studied. Here, we focused on a G5G type natural interruption sequence G-POALO-G from human type XIX collagen, a homotrimer collagen, as this sequence possesses distinct properties compared with those of a pathological similar Gly mutation sequence in collagen mimic peptides. We determined the crystal structures of the host-guest peptide (GPO) 3 -GPOALO-(GPO) 4 to 1.03 Å resolution in two crystal forms. In these structures, the interruption zone brings localized disruptions to the triple helix and introduces a light 6-8° bend with the same directional preference to the whole molecule, which may correspond structurally to the first physiological kink site in type XIX collagen. Furthermore, at the G5G interruption site, the presence of Ala and Leu residues, both with free N-H groups, allows the formation of more direct and water-mediated interchain hydrogen bonds than in the related Gly → Ala structure. These could partly explain the difference in thermal stability between the different interruptions. In addition, our structures provide a detailed view of the dynamic property of such an interrupted zone with respect to hydrogen bonding topology, torsion angles, and helical parameters. Our results, for the first time, also identified the binding of zinc to the end of the triple helix. These findings will shed light on how the interruption sequence influences the conformation of the collagen molecule and provide a structural basis for further functional studies.
Checklist interruption and resumption: A linguistic study
NASA Technical Reports Server (NTRS)
Linde, Charlotte; Goguen, Joseph
1987-01-01
This study forms part of a project investigating the relationships among the formal structure of aviation procedures, the ways in which the crew members are taught to execute them, and the ways in which thet are actually performed in flight. Specifically, this report examines the interactions between the performance of checklists and interruptions, considering both interruptions by radio communications and by other crew members. The data consists of 14 crews' performance of a full mission simulation of a higher ratio of checklist speech acts to all speech acts within the span of the performance of the checklist. Further, it is not number of interruptions but length of interruptions which is associated with crew performance quality. Use of explicit holds is also associated with crew performance.
EVALUATION OF FABRIC MEMBRANES FOR USE IN SALTSTONE DRAIN WATER SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pickenheim, B.; Miller, D.; Burket, P.
2012-03-08
Saltstone Disposal Unit 2 contains a sheet drain fabric intended to separate solids from drain water to be returned to the Salt Feed Tank. A similar system installed in Vault 4 appears to be ineffective in keeping solids out of the drain water return lines. Waste Solidification Engineering is considering installation of an additional fabric membrane to supplement the existing sheet drain in SDU 2. Amerdrain 200 is the product currently installed in SDU 2. This product is no longer available, so Sitedrain 94 was used as the replacement product in this testing. Fabrics with apparent opening sizes of 10,more » 25, 50 and 100 microns were evaluated. These fabrics were evaluated under three separate test conditions, a water flow test, a solids retention test and a grout pour test. A flow test with water showed that installation of an additional filter layer will predictably reduce the theoretical flux through the sheet drain. The manufacturer reports the flux for Sitedrain 94 as 150 gpm/ft{sup 2} by ASTM D-4491. This compares reasonably well with the 117 gpm/ft{sup 2} obtained in this testing. A combination of the 10 micron fabric with Sitedrain 94 could be expected to decrease flux by about 10 times as compared to Sitedrain 94 alone. The different media were used to filter a slag and fly ash mixture from water. Slag historically has the smallest nominal particle size of the premix components. Cement was omitted from the test because of its reactivity with water would prohibit accurately particle size measurements of the filtered samples. All four media sizes were able to remove greater than 95% of particles larger than 100 microns from the slurry. The smaller opening sizes were increasingly effective in removing more particles. The 10 micron filter captured 15% of the total amount of solids used in the test. This result implies that some insoluble particles may still be able to enter the drain water collection system, although the overall solids rejection is significantly improved over the current design. Test boxes were filled with grout to evaluate the performance of the sheet drain and fabrics in a simulated vault environment. All of the tests produced a similar amount of drain water, between 8-11% of the amount of water in the mix, which is expected with the targeted formulation. All of the collected drain waters contained some amount of solids, although the 10 micron filter did not appear to allow any premix materials to pass through. The solids collected from this box are believed to consist of calcium carbonate based on one ICP-AES measurement. Any of the four candidate fabrics would be an improvement over the sheet drain alone relative to solids removal. The 10 micron fabric is the only candidate that stopped all premix material from passing. The 10 micron fabric will also cause the largest decrease in flux. This decrease in flux was not enough to inhibit the total amount of drain water removed, but may lead to increased time to remove standing water prior to subsequent pours in the facility. The acceptability of reduced liquid flux through the 10 micron fabric will depend on the amount of excess water to be removed, the time available for water removal and the total area of fabric installed at the disposal cell.« less
NASA Astrophysics Data System (ADS)
Barnes, C. R.; Best, M. M.; Johnson, F. R.; Phibbs, P.; Pirenne, B.
2009-05-01
NEPTUNE Canada (NC; www.neptunecanada.ca) will complete most of the installation of the world's first regional cabled ocean observatory in late 2009 off Canada's west coast. It will comprise five main observatory nodes (100-2700m water depths) linked by an 800km backbone cable delivering 10kVDC power and 10Gbps communications bandwidth to hundreds of sensors, with a 25-year design life. Infrastructure (100M) and initial operational funding (20M) is secured. University of Victoria (UVic) leads a consortium of 12 Canadian universities, hosts the coastal VENUS cabled observatory, with Ocean Networks Canada (ONC) providing management oversight. Observatory architecture has a trunk and branch topology. Installed in late 2007, the backbone cable loops from/to UVic's Port Alberni shore station. The wet plant's design, manufacture and installation was contracted to Alcatel-Lucent. Each node provides six interface ports for connection of science instrument arrays or extensions. Each port provides dual optical Ethernet links and up to 9kW of electrical power at 400VDC. Junction boxes, designed and built by OceanWorks support up to 10 instruments each and can be daisy- chained. They accommodate both serial and 10/100 Ethernet instruments, and provide a variety of voltages (400V, 48V, 24V, 15V). Backbone equipment has all been qualified and installed; shore station re-equipping is complete; junction boxes are manufactured. A major marine program will deploy nodes and instruments in July-September 2009; instruments to one node will probably be deferred until 2010. Observatory instruments will be deployed in subsurface (boreholes), on seabed, and buoyed through the water column. Over 130 instruments (over 40 different types) will host several hundred sensors; mobile assets include a tethered crawler and a 400m vertical profiler. Experiments will address: earthquake dynamics and tsunami hazards; fluid fluxes in both ocean crust and sediments, including gas hydrates; ocean/climate dynamics, including acidification and nutrient fluxes; deep-sea ecosystems dynamics; and engineering and computer science research. NC's software system interfaces between users and cabled observatory and responds to a three-fold mandate: acquire data from various instruments/sensors underwater; provide lifetime storage and redistribution capabilities for all data; and allow authorized users to remotely and interactively control experiments. Data Management and Archiving System (DMAS) is being developed in-house, with adoption of Service-Oriented Architecture (SOA) and using Web Services to expose the functionality of DMAS' various components. An internal messaging bus allows various functional components to interact through the publish and subscribe paradigm, using Java programming language. DMAS is developing a modern environment for users: data access, data processing and experimentation control within a Web 2.0 environment. This will allow users, on top of data and instrumentation access, to perform data visualization and analysis on-line with either default or custom processing code, as well as simultaneously interacting with each other. These social networking aspects will be within NC's new Oceans 2.0 environment. The observatory is designed to be expandable in its footprint, nodes and instruments and provides a magnificent facility for testing prototypes of new technologies monitored and demonstrated in real-time. NC and ONC invite new scientific and industrial participation, experiments, instrumentation and data services.
Career Interruptions and Subsequent Earnings: A Reexamination Using Swedish Data.
ERIC Educational Resources Information Center
Albrecht, James W.; Edin, Per-Anders; Sundstrom, Marianne; Vroman, Susan B.
1999-01-01
Cross-sectional and panel estimations of Swedish data reveal that different types of career interruptions have different effects on wages, varying by gender. Therefore, human capital depreciation does not entirely account for the negative effect of career interruptions on subsequent wages. (SK)
14 CFR 135.417 - Mechanical interruption summary report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Mechanical interruption summary report. 135... Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... unscheduled stop or diversion from a route, caused by known or suspected mechanical difficulties or...
NASA Astrophysics Data System (ADS)
Niwa, Yoshimitsu; Matsuzaki, Jun; Yokokura, Kunio
The high-speed vacuum circuit breaker, which forced the fault current to zero was investigated. The test circuit breaker consisted of a vacuum interrupter and a high frequency current source. The vacuum interrupter, which had the axial magnetic field electrode and the disk shape electrode, was tested. The arcing period of the high-speed vacuum circuit breaker is much shorter than that of conventional circuit breaker. The arc behavior of the test electrodes immediately after the contact separation was observed by a high-speed video camcorder. The relation between the current waveform just before the current zero and the interruption ability by varying the high frequency current source was investigated experimentally. The results demonstrate the interruption ability and the arc behavior of the high-speed vacuum circuit breaker. The high current interruption was made possible by the low current period just before the current zero, although the arcing time is short and the arc is concentrated.
NASA Astrophysics Data System (ADS)
Niwa, Yoshimitsu; Kaneko, Eiji
Vacuum circuit breakers (VCB) have been widely used for power distribution systems. Vacuum Interrupters, which are the current interruption unit, have been increased its interruption capability with the development of vacuum arc control technology by magnetic field. There are three major type electrodes: disk shaped electrodes, radial magnetic field electrodes, axial magnetic field (AMF) electrodes. In the disk shaped electrode, the vacuum arc between the electrodes is not controlled. In the AMF electrode, the vacuum arc is diffused and stabilized by an axial magnetic field, which is parallel to the arc current. In the last type of electrodes, the vacuum arc column is rotated by magnetic force generated by the current flowing in the electrodes. The interruption current and the voltage of one break VCB is increased to 100 kA, 144 kV respectively. This paper describes basic configurations and functions of VCB, vacuum arc control technology in vacuum interrupters, recent researches and applications of VCB.
Morgan, Phillip L; Patrick, John; Waldron, Samuel M; King, Sophia L; Patrick, Tanya
2009-12-01
Forgetting what one was doing prior to interruption is an everyday problem. The recent soft constraints hypothesis (Gray, Sims, Fu, & Schoelles, 2006) emphasizes the strategic adaptation of information processing strategy to the task environment. It predicts that increasing information access cost (IAC: the time, and physical and mental effort involved in accessing information) encourages a more memory-intensive strategy. Like interruptions, access costs are also intrinsic to most work environments, such as when opening documents and e-mails. Three experiments investigated whether increasing IAC during a simple copying task can be an effective method for reducing forgetting following interruption. IAC was designated Low (all information permanently visible), Medium (a mouse movement to uncover target information), or High (an additional few seconds to uncover such information). Experiment 1 found that recall improved across all three levels of IAC. Subsequent experiments found that High IAC facilitated resumption after interruption, particularly when interruption occurred on half of all trials (Experiment 2), and improved prospective memory following two different interrupting tasks, even when one involved the disruptive effect of using the same type of resource as the primary task (Experiment 3). The improvement of memory after interruption with increased IAC supports the prediction of the soft constraints hypothesis. The main disadvantage of a high access cost was a reduction in speed of task completion. The practicality of manipulating IAC as a design method for inducing a memory-intensive strategy to protect against forgetting is discussed. Copyright 2009 APA
Interrupted Visual Searches Reveal Volatile Search Memory
ERIC Educational Resources Information Center
Shen, Y. Jeremy; Jiang, Yuhong V.
2006-01-01
This study investigated memory from interrupted visual searches. Participants conducted a change detection search task on polygons overlaid on scenes. Search was interrupted by various disruptions, including unfilled delay, passive viewing of other scenes, and additional search on new displays. Results showed that performance was unaffected by…
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false CAMP: Mechanical interruption summary... Ownership Operations Program Management § 91.1417 CAMP: Mechanical interruption summary report. Each program... route, caused by known or suspected mechanical difficulties or malfunctions that are not required to be...
NASA Technical Reports Server (NTRS)
1980-01-01
The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.
Stefanyshyn-Piper and Tanner perform first EVA during STS-115 / Expedition 13 joint operations
2006-09-12
S115-E-05663 (12 Sept. 2006) --- Astronauts Joseph R. Tanner (left) and Heidemarie M. Stefanyshyn-Piper, both STS-115 mission specialists, work in tandem during the mission's first session of extravehicular activity (EVA) while the Space Shuttle Atlantis was docked with the International Space Station. During today's spacewalk, Tanner and Stefanyshyn-Piper worked to connect power cables on the P3/P4 truss, release restraints for the Solar Array Blanket Boxes that hold the solar arrays and the Beta Gimbal Assemblies that serve as the structural link between the truss' integrated electronics and the Solar Array Wings. Stefanyshyn-Piper and Tanner also installed the Solar Alpha Rotary Joint and completed the connection of electrical cables between the new P3 truss and the P1 truss.
Project Echo: 961-Mc Lower - Sideband Up - Converter for Satellite-Tracking Radar
NASA Technical Reports Server (NTRS)
Uenohara, M.; Seidel, H.
1961-01-01
A 961-Mc lower-sideband up-converter was specially designed to serve as preamplifier for the satellite-tracking radar used in Project Echo. The amplifier and its power supply are separately boxed and are installed directly behind the tracking antenna. The amplifier has been functioning most satisfactorily and has been used in routine manner to track the Echo satellite from horizon to horizon. This paper describes the design considerations, and details the special steps taken to ensure that the amplifier met the particular system needs of low noise, absolute stability, insensitivity to temperature fluctuations, and high input-power level before the onset of gain compression. The satisfactory operation of this amplifier confirms the great potentiality of parametric amplifiers as stable, low-noise, high-frequency receivers.
Solar heating system at Quitman County Bank, Marks, Mississippi
NASA Technical Reports Server (NTRS)
1980-01-01
Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.
Barbosa, F.; Bessuille, J.; Chudakov, E.; ...
2017-02-03
We present the GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector that is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed inmore » 2017. In addition, we present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.« less
Handling 20 tons of honeycomb mirror with a very gentle touch
NASA Astrophysics Data System (ADS)
Davison, Warren B.; Williams, Joseph T.; Hill, John M.
1998-08-01
The 6.5 meter and 8.4 meter mirrors being produced at Steward Observatory have to be lifted, turned, ground, polished, shipped and installed without exceeding 0.7 MPa (100 psi) stress in the glass. Many pieces of specialized equipment and some innovations are required to do this on a tight budget. We have developed lifting fixtures that are either glued on or held by vacuum. We have also designed turning rings that fill our lab, and transportation boxes to hold the mirror horizontal, vertical or in a ship. The sheer size and mass of the mirrors and equipment, plus the very stringent constraints makes the solutions interesting. This may not be the part of telescope design and construction that attracts the most attention, unless...
Field Trial on a Rack-mounted DC Power Supply System with 80-Ah Lithium-ion Batteries
NASA Astrophysics Data System (ADS)
Matsushima, Toshio
Using an industrial lithium-ion battery that has higher energy density than conventional valve-regulated lead-acid batteries, a rack-mounted DC-power-supply system was assembled and tested at a base transceiver station (BTS) offering actual services. A nominal output voltage and maximum output current of the system is 53.5V and 20A, respectively. An 80-Ah lithium-ion battery composed of 13 cells connected in series was applied in the system and maintained in a floating charge method. The DC-power-supply system was installed in a 19-inch power rack in the telecommunications equipment box at BTS. The characteristics of the 80Ah lithium-ion battery, specifications of the DC-power-supply system and field-test results were shown in this paper.
76 FR 27637 - Supplemental Priorities for Discretionary Grant Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-12
.... Interrupted time series design means a type of quasi-experimental study (as defined in this notice) in which... design is an adaptation of an interrupted time series design that relies on the comparison of treatment... notice), interrupted time series designs (as defined in this notice), or regression discontinuity designs...
75 FR 47284 - Secretary's Priorities for Discretionary Grant Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... the most currently available data. Interrupted time series design \\4\\ means a type of quasi... findings. \\4\\ A single subject or single case design is an adaptation of an interrupted time series design...), interrupted time series designs (as defined in this notice), or regression discontinuity designs (as defined...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-739] Certain Ground Fault Circuit... importation of certain ground fault circuit interrupters and products containing the same by reason of... entry of ground fault circuit interrupters and products containing the same that infringe one or more of...
The Interrupted Intercourse in the Election Communication: Pragmatic Aspect
ERIC Educational Resources Information Center
Andryuchshenko, Olga K.; Suyunova, Gulnara S.; Nygmetova, Bibigul Dz.; Garanina, Ekaterina P.
2016-01-01
The article provides analysis of the interrupted communication as part of the communication in the election discourse. The authors explored the most typical reasons for the interrupted communication in the electoral discourse analyzed communication failures as a kind of ineffective communication. Communication failures are presented as a result of…
Interruption of a dry-type transformer in no-load by a vacuum circuit-breaker
NASA Astrophysics Data System (ADS)
Vandenheuvel, W. M. C.; Daalder, J. E.; Boone, M. J. M.; Wilmes, L. A. H.
1983-08-01
Overvoltages generated during interruption of a dry type delta-star connected transformer in no load by a vacuum breaker were studied. During interruption of inrush current 37% of the phase-to-ground overvoltages were 5 pu, and 6% 7 pu. Comparison of experimental and theoretical results using Boyle's model shows no discrepancy for inrush currents and clean overvoltages from the steady-state interruption. Overvoltages due to repetitive reignitions (not covered by Boyle's model) are higher than the calculated values during steady-state switching.
Microelectromechanical safe arm device
Roesler, Alexander W [Tijeras, NM
2012-06-05
Microelectromechanical (MEM) apparatus and methods for operating, for preventing unintentional detonation of energetic components comprising pyrotechnic and explosive materials, such as air bag deployment systems, munitions and pyrotechnics. The MEM apparatus comprises an interrupting member that can be moved to block (interrupt) or complete (uninterrupt) an explosive train that is part of an energetic component. One or more latching members are provided that engage and prevent the movement of the interrupting member, until the one or more latching members are disengaged from the interrupting member. The MEM apparatus can be utilized as a safe and arm device (SAD) and electronic safe and arm device (ESAD) in preventing unintentional detonations. Methods for operating the MEM apparatus include independently applying drive signals to the actuators coupled to the latching members, and an actuator coupled to the interrupting member.
Suicide Risk Characteristics among Aborted, Interrupted, and Actual Suicide Attempters
Burke, Taylor A.; Hamilton, Jessica L.; Ammerman, Brooke A.; Stange, Jonathan P.; Alloy, Lauren B.
2017-01-01
Few studies have investigated suicide risk characteristics associated with interrupted and aborted suicide attempts. The present study aimed to empirically examine whether assessing a history of interrupted and aborted suicide attempts is valuable when assessing suicide risk, given the relative lack of literature in this area to date. To inform this question, the current study examined differences in risk factors for suicidal behavior among individuals who have carried out a suicide attempt, individuals who report having a history of only interrupted and/or aborted suicide attempts, and non-attempter controls. Approximately 447 undergraduates (M = 21.10 years; SD = 4.16; 77.6% female) completed measures of carried out suicide attempts, interrupted suicide attempts, aborted suicide attempts, acquired capability for suicide, suicide likelihood, depressive symptoms, suicidal ideation, and non-suicidal self-injury. Results suggest that a faction of individuals endorse interrupted and/or aborted suicide attempts (8.7%), but do not endorse carried out suicide attempts, even in non-clinical samples. Furthermore, results suggest that there are few clinically meaningful differences between those with a history of carried out suicide attempts and interrupted/aborted suicide attempts, suggesting that individuals with a history of these lesser studied suicidal behaviors are an important group to target for suicide risk intervention. PMID:27344029
Bolwell, C F; Rogers, C W; French, N P; Firth, E C
2013-02-01
Few studies have investigated the effect of having interruptions during training on future training and racing performance in Thoroughbred racehorses. The aim of this paper was to investigate the effect of having an interruption before the first trial on starting in a trial or a race. A prospective cohort study was used to record the training activity of a cohort of Thoroughbred racehorses, over two racing seasons. Fourteen racehorse trainers recorded information on the distances worked at canter and at fast speeds (<15s/200 m) and provided reasons for horses not training, or for having interruptions (break from training). Trial and racing results were obtained from the New Zealand Thoroughbred Racing online database. A Cox proportional hazards regression model was used to investigate two outcome measures of performance: (1) time to the first trial and (2) time to the first race. The type of interruption that had occurred before the first trial was the main exposure of interest, and was grouped into: no interruption, voluntary (no known condition or disease present) and involuntary interruptions (due to the presence of a condition or disease). A total of 160/200 (80%) horses started in at least one trial and 100/205 (48%) horses started in at least one race during the study period. The median time to starting in a trial or a race differed significantly (p<0.001) with the type of interruption. The hazard of starting in a trial was lower for horses experiencing voluntary and involuntary interruptions (p<0.001) but there was no association with starting in a race, after adjusting for confounding variables. As age at the start of training increased the hazard of starting in a trial decreased. Horses accumulating longer distances at 15s/200 m had a higher hazard of starting in a trial, whilst horses accumulating fewer events at high speed and fewer trials had a reduced hazard of starting in a race. There was significant clustering at the trainer level for both the outcomes investigated. Interruptions to training had an effect on the time to, and hazard of, a trial but not a race start. The timing of these interruptions may have implications for future racing success and career longevity. Copyright © 2012 Elsevier B.V. All rights reserved.
Geldermann, Ina; Grouls, Christoph; Kuhl, Christiane; Deserno, Thomas M; Spreckelsen, Cord
2013-08-01
Usability aspects of different integration concepts for picture archiving and communication systems (PACS) and computer-aided diagnosis (CAD) were inquired on the example of BoneXpert, a program determining the skeletal age from a left hand's radiograph. CAD-PACS integration was assessed according to its levels: data, function, presentation, and context integration focusing on usability aspects. A user-based study design was selected. Statements of seven experienced radiologists using two alternative types of integration provided by BoneXpert were acquired and analyzed using a mixed-methods approach based on think-aloud records and a questionnaire. In both variants, the CAD module (BoneXpert) was easily integrated in the workflow, found comprehensible and fitting in the conceptual framework of the radiologists. Weak points of the software integration referred to data and context integration. Surprisingly, visualization of intermediate image processing states (presentation integration) was found less important as compared to efficient handling and fast computation. Seamlessly integrating CAD into the PACS without additional work steps or unnecessary interrupts and without visualizing intermediate images may considerably improve software performance and user acceptance with efforts in time.
Westbrook, Johanna I; Raban, Magdalena Z; Walter, Scott R; Douglas, Heather
2018-01-09
Interruptions and multitasking have been demonstrated in experimental studies to reduce individuals' task performance. These behaviours are frequently used by clinicians in high-workload, dynamic clinical environments, yet their effects have rarely been studied. To assess the relative contributions of interruptions and multitasking by emergency physicians to prescribing errors. 36 emergency physicians were shadowed over 120 hours. All tasks, interruptions and instances of multitasking were recorded. Physicians' working memory capacity (WMC) and preference for multitasking were assessed using the Operation Span Task (OSPAN) and Inventory of Polychronic Values. Following observation, physicians were asked about their sleep in the previous 24 hours. Prescribing errors were used as a measure of task performance. We performed multivariate analysis of prescribing error rates to determine associations with interruptions and multitasking, also considering physician seniority, age, psychometric measures, workload and sleep. Physicians experienced 7.9 interruptions/hour. 28 clinicians were observed prescribing 239 medication orders which contained 208 prescribing errors. While prescribing, clinicians were interrupted 9.4 times/hour. Error rates increased significantly if physicians were interrupted (rate ratio (RR) 2.82; 95% CI 1.23 to 6.49) or multitasked (RR 1.86; 95% CI 1.35 to 2.56) while prescribing. Having below-average sleep showed a >15-fold increase in clinical error rate (RR 16.44; 95% CI 4.84 to 55.81). WMC was protective against errors; for every 10-point increase on the 75-point OSPAN, a 19% decrease in prescribing errors was observed. There was no effect of polychronicity, workload, physician gender or above-average sleep on error rates. Interruptions, multitasking and poor sleep were associated with significantly increased rates of prescribing errors among emergency physicians. WMC mitigated the negative influence of these factors to an extent. These results confirm experimental findings in other fields and raise questions about the acceptability of the high rates of multitasking and interruption in clinical environments. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
PolyQ repeat expansions in ATXN2 associated with ALS are CAA interrupted repeats.
Yu, Zhenming; Zhu, Yongqing; Chen-Plotkin, Alice S; Clay-Falcone, Dana; McCluskey, Leo; Elman, Lauren; Kalb, Robert G; Trojanowski, John Q; Lee, Virginia M-Y; Van Deerlin, Vivianna M; Gitler, Aaron D; Bonini, Nancy M
2011-03-29
Amyotrophic lateral sclerosis (ALS) is a devastating, rapidly progressive disease leading to paralysis and death. Recently, intermediate length polyglutamine (polyQ) repeats of 27-33 in ATAXIN-2 (ATXN2), encoding the ATXN2 protein, were found to increase risk for ALS. In ATXN2, polyQ expansions of ≥ 34, which are pure CAG repeat expansions, cause spinocerebellar ataxia type 2. However, similar length expansions that are interrupted with other codons, can present atypically with parkinsonism, suggesting that configuration of the repeat sequence plays an important role in disease manifestation in ATXN2 polyQ expansion diseases. Here we determined whether the expansions in ATXN2 associated with ALS were pure or interrupted CAG repeats, and defined single nucleotide polymorphisms (SNPs) rs695871 and rs695872 in exon 1 of the gene, to assess haplotype association. We found that the expanded repeat alleles of 40 ALS patients and 9 long-repeat length controls were all interrupted, bearing 1-3 CAA codons within the CAG repeat. 21/21 expanded ALS chromosomes with 3CAA interruptions arose from one haplotype (GT), while 18/19 expanded ALS chromosomes with <3CAA interruptions arose from a different haplotype (CC). Moreover, age of disease onset was significantly earlier in patients bearing 3 interruptions vs fewer, and was distinct between haplotypes. These results indicate that CAG repeat expansions in ATXN2 associated with ALS are uniformly interrupted repeats and that the nature of the repeat sequence and haplotype, as well as length of polyQ repeat, may play a role in the neurological effect conferred by expansions in ATXN2.
Belcher, Britni R; Berrigan, David; Papachristopoulou, Alexia; Brady, Sheila M; Bernstein, Shanna B; Brychta, Robert J; Hattenbach, Jacob D; Tigner, Ira L; Courville, Amber B; Drinkard, Bart E; Smith, Kevin P; Rosing, Douglas R; Wolters, Pamela L; Chen, Kong Y; Yanovski, Jack A
2015-10-01
Limited data suggest that interrupting sedentary behaviors with activity improves metabolic parameters in adults. We tested whether interrupting sitting with short, moderate-intensity walking bouts improved glucose tolerance in children. Participants underwent two experimental conditions in random order on different days: continuous sitting for 3 hours or sitting interrupted by walking (3 min of moderate-intensity walking every 30 min). Insulin, C-peptide, glucose, and free fatty acids were measured every 30 minutes for 3 hours during an oral glucose tolerance test. Area under the curve (AUC) was calculated from hormone and substrate measurements. Children were given a buffet meal after each condition. The study was conducted at the National Institutes of Health Hatfield Clinical Research Center. Twenty-eight normal-weight 7-11 year olds participated. Patterns of substrate/hormone secretion and AUC, as well as energy intake, were examined by experimental condition. Interrupting sitting resulted in a 32% lower insulin AUC (P < .001), 17% lower C-peptide AUC (P < .001), and 7% lower glucose AUC (P = .018) vs continuous sitting. Mixed model results indicated that insulin (P = .036) and free fatty acid concentrations (P = .009) were significantly lower in the interrupted vs the continuous sitting condition. Lunchtime buffet meal energy intake did not significantly differ between the conditions (975 ± 387 vs 963 ± 309 kcal; P = .85). Interrupting sedentary time with brief moderate-intensity walking improved short-term metabolic function in non-overweight children without increasing subsequent energy intake. These findings suggest that interrupting sedentary behavior may be a promising prevention strategy for reducing cardiometabolic risk in children.
Interruptions disrupt reading comprehension.
Foroughi, Cyrus K; Werner, Nicole E; Barragán, Daniela; Boehm-Davis, Deborah A
2015-06-01
Previous research suggests that being interrupted while reading a text does not disrupt the later recognition or recall of information from that text. This research is used as support for Ericsson and Kintsch's (1995) long-term working memory (LT-WM) theory, which posits that disruptions while reading (e.g., interruptions) do not impair subsequent text comprehension. However, to fully comprehend a text, individuals may need to do more than recognize or recall information that has been presented in the text at a later time. Reading comprehension often requires individuals to connect and synthesize information across a text (e.g., successfully identifying complex topics such as themes and tones) and not just make a familiarity-based decision (i.e., recognition). The goal for this study was to determine whether interruptions while reading disrupt reading comprehension when the questions assessing comprehension require participants to connect and synthesize information across the passage. In Experiment 1, interruptions disrupted reading comprehension. In Experiment 2, interruptions disrupted reading comprehension but not recognition of information from the text. In Experiment 3, the addition of a 15-s time-out prior to the interruption successfully removed these negative effects. These data suggest that the time it takes to process the information needed to successfully comprehend text when reading is greater than that required for recognition. Any interference (e.g., an interruption) that occurs during the comprehension process may disrupt reading comprehension. This evidence supports the need for transient activation of information in working memory for successful text comprehension and does not support LT-WM theory. (c) 2015 APA, all rights reserved).
Regioselective synthesis of C3 alkylated and arylated benzothiophenes
Shrives, Harry J.; Fernández-Salas, José A.; Hedtke, Christin; Pulis, Alexander P.; Procter, David J.
2017-01-01
Benzothiophenes are heterocyclic constituents of important molecules relevant to society, including those with the potential to meet modern medical challenges. The construction of molecules would be vastly more efficient if carbon–hydrogen bonds, found in all organic molecules, can be directly converted into carbon–carbon bonds. In the case of elaborating benzothiophenes, functionalization of carbon–hydrogen bonds at carbon-number 3 (C3) is markedly more demanding than at C2 due to issues of regioselectivity (C3 versus C2), and the requirement of high temperatures, precious metals and the installation of superfluous directing groups. Herein, we demonstrate that synthetically unexplored but readily accessible benzothiophene S-oxides serve as novel precursors for C3-functionalized benzothiophenes. Employing an interrupted Pummerer reaction to capture and then deliver phenol and silane coupling partners, we have discovered a directing group-free method that delivers C3-arylated and -alkylated benzothiophenes with complete regioselectivity, under metal-free and mild conditions. PMID:28317882
Monitoring the battery status for photovoltaic systems
NASA Astrophysics Data System (ADS)
Kim, Myungsoo; Hwang, Euijin
Photovoltaic power systems in Korea have been installed in remote islands where it is difficult to connect the utilities. Lead/acid batteries are used as an energy storage device for the stand-alone photovoltaic system. Hence, monitoring the battery status of photovoltaic systems is quite important to extend the total system service life. To monitor the state-of-charge of batteries, we adopted a current interrupt technique to measure the internal resistance of the battery. The internal resistance increases at the end of charge/discharge steps and also with cycles. The specific gravity of the electrolyte was measured in relation to the state-of-charge. A home-made optical hydrometer was utilized for automatic monitoring of the specific gravity. It is shown that the specific gravity and stratification increase with cycle number. One of the photovoltaic systems in a remote island, Ho-do, which has 90 kW peak power was checked for actual operational conditions such as solar generation, load, and battery status.
Rudolf, Miriam; Pöppel, Manfred; Fröhlich, Andreas; Breithaupt, Angele; Teifke, Jens; Blohm, Ulrike; Mettenleiter, Thomas; Beer, Martin; Harder, Timm
2010-10-04
A licensed, inactivated vaccine based on a low pathogenic avian influenza virus strain (H5N2) was evaluated in layer hens kept under field conditions during a 2-year period. Vaccine efficacy was investigated by specific antibodies and by challenge-contact experiments using highly pathogenic avian influenza viruses (HPAIV) H5N1. Basic immunization with two applications induced clinical protection. Virus excretion by vaccinated hens was significantly reduced compared to non-vaccinated controls; transmission to non-vaccinated and vaccinated contact birds was not fully interrupted. Vaccination efficacy is influenced by several factors including antigenic relatedness between vaccine and field strains, but also by species, age and type of commercial uses of the host. Limitations and risks of HPAIV vaccination as silent spread of HPAIV and emergence of escape mutants must be considered a priori and appropriate corrective measures have to be installed. Copyright © 2010 Elsevier Ltd. All rights reserved.
77 FR 18229 - Applications for New Awards; Investing in Innovation Fund, Validation Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-27
... the appearance of a conflict of interest. Interrupted time series design \\8\\ means a type of quasi... single case design is an adaptation of an interrupted time series design that relies on the comparison of... notice), interrupted time series designs (as defined in this notice), or regression discontinuity designs...
76 FR 32148 - Applications for New Awards; Investing in Innovation Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
.... Interrupted time series design \\5\\ means a type of quasi- experimental study in which the outcome of interest... interrupted time series design that relies on the comparison of treatment effects on a single subject or group... matched comparison group designs (as defined in this notice), interrupted time series designs (as defined...
77 FR 18216 - Applications for New Awards; Investing in Innovation Fund, Scale-Up Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-27
... evaluation and prevents even the appearance of a conflict of interest. Interrupted time series design \\8... findings. \\8\\ A single subject or single case design is an adaptation of an interrupted time series design... matched comparison group designs (as defined in this notice), interrupted time series designs (as defined...
76 FR 32171 - Applications for New Awards; Investing in Innovation Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
... conflict of interest. Interrupted time series design \\5\\ means a type of quasi- experimental study in... single case design is an adaptation of an interrupted time series design that relies on the comparison of...), interrupted time series designs (as defined in this notice), or regression discontinuity designs (as defined...
76 FR 32159 - Applications for New Awards; Investing in Innovation Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
... conflict of interest. Interrupted time series design \\5\\ means a type of quasi- experimental study in which... design is an adaptation of an interrupted time series design that relies on the comparison of treatment...), interrupted time series designs (as defined in this notice), or regression discontinuity designs (as defined...
Interruptions and Failure in Higher Education: Evidence from ISEG-UTL
ERIC Educational Resources Information Center
Chagas, Margarida; Fernandaes, Graca Leao
2011-01-01
Failure in higher education (HE) is the outcome of multiple time-dependent determinants. Interruptions in students' individual school trajectories are one of them, and that is why research on this topic has been attracting much attention these days. From an individual point of view, it is expected that interruptions in school trajectory, whatever…
Low latency counter event indication
Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY
2008-09-16
A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.
Low latency counter event indication
Gara, Alan G.; Salapura, Valentina
2010-08-24
A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.
HIV models for treatment interruption: Adaptation and comparison
NASA Astrophysics Data System (ADS)
Hillmann, Andreas; Crane, Martin; Ruskin, Heather J.
2017-10-01
In recent years, Antiretroviral Therapy (ART) has become commonplace for treating HIV infections, although a cure remains elusive, given reservoirs of replicating latently-infected cells, which are resistant to normal treatment regimes. Treatment interruptions, whether ad hoc or structured, are known to cause a rapid increase in viral production to detectable levels, but numerous clinical trials remain inconclusive on the dangers inherent in this resurgence. In consequence, interest in examining interruption strategies has recently been rekindled. This overview considers modelling approaches, which have been used to explore the issue of treatment interruption. We highlight their purpose and the formalisms employed and examine ways in which clinical data have been used. Implementation of selected models is demonstrated, illustrative examples provided and model performance compared for these cases. Possible extensions to bottom-up modelling techniques for treatment interruptions are briefly discussed.
Preventing messaging queue deadlocks in a DMA environment
Blocksome, Michael A; Chen, Dong; Gooding, Thomas; Heidelberger, Philip; Parker, Jeff
2014-01-14
Embodiments of the invention may be used to manage message queues in a parallel computing environment to prevent message queue deadlock. A direct memory access controller of a compute node may determine when a messaging queue is full. In response, the DMA may generate and interrupt. An interrupt handler may stop the DMA and swap all descriptors from the full messaging queue into a larger queue (or enlarge the original queue). The interrupt handler then restarts the DMA. Alternatively, the interrupt handler stops the DMA, allocates a memory block to hold queue data, and then moves descriptors from the full messaging queue into the allocated memory block. The interrupt handler then restarts the DMA. During a normal messaging advance cycle, a messaging manager attempts to inject the descriptors in the memory block into other messaging queues until the descriptors have all been processed.
Optical fibres in the radiation environment of CERN
NASA Astrophysics Data System (ADS)
Guillermain, E.
2017-11-01
CERN, the European Organization for Nuclear Research (in Geneva, Switzerland), is home to a complex scientific instrument: the 27-kilometre Large Hadron Collider (LHC) collides beams of high-energy particles at close to the speed of light. Optical fibres are widely used at CERN, both in surface areas (e.g. for inter-building IT networks) and in the accelerator complex underground (e.g. for cryogenics, vacuum, safety systems). Optical fibres in the accelerator are exposed to mixed radiation fields (mainly composed of protons, pions, neutrons and other hadrons, gamma rays and electrons), with dose rates depending on the particular installation zone, and with radiation levels often significantly higher than those encountered in space. In the LHC and its injector chain radiation levels range from relatively low annual doses of a few Gy up to hundreds of kGy. Optical fibres suffer from Radiation Induced Attenuation (RIA, expressed in dB per unit length) that affect light transmission and which depends on the irradiation conditions (e.g. dose rate, total dose, temperature). In the CERN accelerator complex, the failure of an optical link can affect the proper functionality of control or monitoring systems and induce the interruption of the accelerator operation. The qualification of optical fibres for installation in critical radiation areas is therefore crucial. Thus, all optical fibre types installed in radiation areas at CERN are subject to laboratory irradiation tests, in order to evaluate their RIA at different total dose and dose rates. This allows the selection of the appropriate optical fibre type (conventional or radiation resistant) compliant with the requirements of each installation. Irradiation tests are performed in collaboration with Fraunhofer INT (irradiation facilities and expert team in Euskirchen, Germany). Conventional off-the-shelf optical fibres can be installed for optical links exposed to low radiation levels (i.e. annual dose typically below few kGy). Nevertheless, the conventional optical fibres must be carefully qualified as a spread in RIA of factor 10 is observed among optical fibres of different types and dopants. In higher radiation areas, special radiation resistant optical fibres are installed. For total dose above 1 kGy, the RIA of these special optical fibres is at least 10 times lower than the conventional optical fibres RIA at same irradiation conditions. 2400 km of these special radiation resistant optical fibres were recently procured at CERN. As part of this procurement process, a quality assurance plan including the irradiation testing of all 65 produced batches was set up. This presentation will review the selection process of the appropriate optical fibre types to be installed in the radiation environment of CERN. The methodology for choosing the irradiation parameters for the laboratory tests will be discussed together with an overview of the RIA of different optical fibre types under several irradiation conditions.