Kinetic Monte Carlo (kMC) simulation of carbon co-implant on pre-amorphization process.
Park, Soonyeol; Cho, Bumgoo; Yang, Seungsu; Won, Taeyoung
2010-05-01
We report our kinetic Monte Carlo (kMC) study of the effect of carbon co-implant on the pre-amorphization implant (PAL) process. We employed BCA (Binary Collision Approximation) approach for the acquisition of the initial as-implant dopant profile and kMC method for the simulation of diffusion process during the annealing process. The simulation results implied that carbon co-implant suppresses the boron diffusion due to the recombination with interstitials. Also, we could compare the boron diffusion with carbon diffusion by calculating carbon reaction with interstitial. And we can find that boron diffusion is affected from the carbon co-implant energy by enhancing the trapping of interstitial between boron and interstitial.
NASA Astrophysics Data System (ADS)
Mathayan, Vairavel; Kothalamuthu, Saravanan; Gnanasekaran, Jaiganesh; Balakrishnan, Sundaravel; Panigrahi, Binaykumar
2018-01-01
The O18 and self ions are implanted at same depth in Fe (1 1 0) crystal and annealed to study the oxygen trapping under excess self interstitial defects. Rutherford backscattering spectrometry, nuclear reaction analysis and channeling measurements have been performed to determine the lattice site position of O18. The presence of dislocation loops is confirmed by energy-dependent dechanneling parameter measurements. From the tilt angular scans of Fe and O18 signals along 〈1 0 0〉, 〈1 1 0〉 axes, O18 is found to be displaced 0.2 Å from tetrahedral towards octahedral interstitial site in O18. Similar lattice site location of oxygen with the displacement of 0.37 Å is predicted by density functional theory calculations for the interaction of oxygen with 〈1 0 0〉 interstitial dislocation loop structure. Our results provide strong evidence on oxygen trapping at interstitial dislocation loops in the presence of excess interstitial defects in iron.
Tribological properties and surface structures of ion implanted 9Cr18Mo stainless steels
NASA Astrophysics Data System (ADS)
Fengbin, Liu; Guohao, Fu; Yan, Cui; Qiguo, Sun; Min, Qu; Yi, Sun
2013-07-01
The polished quenched-and-tempered 9Cr18Mo steels were implanted with N ions and Ti ions respectively at a fluence of 2 × 1017 ions/cm2. The mechanical properties of the samples were investigated by using nanoindenter and tribometer. The results showed that the ion implantations would improve the nanohardness and tribological property, especially N ion implantation. The surface analysis of the implanted samples was carried out by using XRD, XPS and AES. It indicated that the surface exhibits graded layers after ion implantation. For N ion implantation, the surface about 20 nm thickness is mainly composed of supersaturated interstitial N solid solution, oxynitrides, CrxCy phase and metal nitrides. In the subsurface region, the metal nitrides dominate and the other phases disappear. For Ti ion implantation, the surface of about 20 nm thickness is mainly composed of titanium oxides and carbon amorphous phase, the interstitial solid solution of Ti in Fe is abundant in the subsurface region. The surface components and structures have significant contributions to the improved mechanical properties.
Iodine 125 source in interstitial tumor therapy. Clinical and biological considerations.
Kim, J H; Hilaris, B
1975-01-01
Our clinical experience with interstitial tumor therapy is presented in 2 groups of patients: 98 patients with metastatic carcinoma in neck lymph nodes implanted with iodine 125, iridium 192 or radon 222 encapsulated sources, and 105 patients with primary unresectable lung tumors, which were implanted either with radon 222 or iodine 125 seeds. The local tumor control rates with iodine 125, radon 222 and iridium 192 were 78 per cent (38/49), 65 per cent (15/23) and 58 per cent (7/12), while the local complication rates were 17 per cent, 35 per cent and 43 per cent, respectively. An analysis of the tumor control rate as a function of the implanted tumor dose shows that the iodine 125 implants with a delivery of the minimal effective tumor dose of 16,000 rads have a higher therapeutic effect than either radon 222 or iridium 192. The results of the patients with unresectable lung tumors similarly show that the implants with iodine 125 sources are superior to those with radon 222. The advantages could stem from the better spatial dose distribution, and from radiobiologic considerations associated with low dose rates, continous irradiation, and possibly gains in RBE. There present clinical data clearly demonstrate that iodine 125 seeds have a higher therapeutic ratio than radon 222 seeds. There are, in addition, distinct physical advantages making iodine 125 an attractive substitute for radon 222 for the interstitial implantation of malignant tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leung, S.
1990-09-01
Since 1984, perineal template/needle techniques for interstitial implantation of gynecologic cancer-cervix, vagina, vulva-have been developed at the Peter MacCallum Cancer Institute. The Paris System of dosimetry has been used resulting in greater dose homogeneity, fewer needles and radioactive sources and considerable simplification and ease of implantation compared with comparable techniques developed in the United States. Principles and techniques of implantation are described in detail.
Meng, J; Zhang, J; Zhuang, Q-W; Wang, X; Li, Z-P; Gu, Q-P
2014-10-01
To investigate the efficacy as well as the complications involved in the use of interstitial Iodine-125 implantation for the treatment of oral cavity and maxillofacial carcinomas. Fifteen patients with oral cavity and maxillofacial carcinomas received treatment planning system (TPS)-guided interstitial Iodine-125 implantation. The apparent activity per particle ranged from 0.6 mCi (2.22MBq) to 0.7 mCi (2.59MBq). The matched peripheral dose delivered by radioactive seeds ranged from 90 to 120 Gy. The efficacy of the treatment and the postoperative complications were evaluated during follow-up. The seeds were implanted successfully in all 15 patients and median number of seeds implanted was 36.53. CT scans were performed in all patients at 1-6 months postoperatively. During follow-up at 6-27 months, seed migration occurred and a good local tumor control was achieved with an overall response of 86.7%. No severe side effects were observed. TPS-guided interstitial Iodine-125 implantation is an effective and safe procedure with minimal invasiveness for the treatment of oral cavity and maxillofacial carcinomas, and it effectively prevents the recurrence of cancer and short-term lymphatic metastasis.
Paulus, J A; Richardson, J S; Tucker, R D; Park, J B
1996-04-01
Ferromagnetic alloys heated by magnetic induction have been investigated as interstitial hyperthermia delivery implants for over a decade, utilizing low Curie temperatures to provide thermal self-regulation. The minimally invasive method is attractive for fractionated thermal treatment of tumors which are not easily heated by focused microwave or ultrasound techniques. Past analyses of ferromagnetic seeds by other authors depict poor experimental correlation with theoretical heating predictions. Improvements in computer hardware and commercially available finite element analysis software have simplified the analysis of inductively heated thermal seeds considerably. This manuscript examines end effects of finite length implants and nonlinear magnetic material properties to account for previous inconsistencies. Two alloys, Ni-28 wt% Cu (NiCu) and Pd-6.15 wt% Co (PdCo), were used for comparison of theoretical and experimental calorimetric results. Length to diameter (L/d) ratios of over 20 for cylindrical seeds are necessary for minimization of end effects. Magnetic properties tested for alloys of NiCu and PdCo illustrate considerable nonlinearity of these materials in field strength ranges used for induction heating. Field strength dependent magnetic permeabilities and calorimetric data illustrate that more detailed material information must be included to accurately estimate induction power loss for these implants.
Time scales of transient enhanced diffusion: Free and clustered interstitials
NASA Astrophysics Data System (ADS)
Cowern, N. E. B.; Huizing, H. G. A.; Stolk, P. A.; Visser, C. C. G.; de Kruif, R. C. M.; Kyllesbech Larsen, K.; Privitera, V.; Nanver, L. K.; Crans, W.
1996-12-01
Transient enhanced diffusion (TED) and electrical activation after nonamorphizing Si implantations into lightly B-doped Si multilayers shows two distinct timescales, each related to a different class of interstitial defect. At 700°C, ultrafast TED occurs within the first 15 s with a B diffusivity enhancement of > 2 × 10 5. Immobile clustered B is present at low concentration levels after the ultrafast transient and persists for an extended period (˜ 10 2-10 3 s). The later phase of TED exhibits a near-constant diffusivity enhancement of ≈ 1 × 10 4, consistent with interstitial injection controlled by dissolving {113} interstitial clusters. The relative contributions of the ultrafast and regular TED regimes to the final diffusive broadening of the B profile depends on the proportion of interstitials that escape capture by {113} clusters growing within the implant damage region upon annealing. Our results explain the ultrafast TED recently observed after medium-dose B implantation. In that case there are enough B atoms to trap a large proportion of interstitials in SiB clusters, and the remaining interstitials contribute to TED without passing through an intermediate {113} defect stage. The data on the ultrafast TED pulse allows us to extract lower limits for the diffusivities of the Si interstitial ( DI > 2 × 10 -10 cm 2s -1) and the B interstitial(cy) defect ( DBi > 2 × 10 -13 cm 2s -1) at 700°C.
NASA Astrophysics Data System (ADS)
Wootton, Jeffery H.; Prakash, Punit; Hsu, I.-Chow Joe; Diederich, Chris J.
2011-07-01
Catheter-based ultrasound devices provide a method to deliver 3D conformable heating integrated with HDR brachytherapy delivery. Theoretical characterization of heating patterns was performed to identify implant strategies for these devices which can best be used to apply hyperthermia to cervical cancer. A constrained optimization-based hyperthermia treatment planning platform was used for the analysis. The proportion of tissue >=41 °C in a hyperthermia treatment volume was maximized with constraints Tmax <= 47 °C, Trectum <= 41.5 °C, and Tbladder <= 42.5 °C. Hyperthermia treatment was modeled for generalized implant configurations and complex configurations from a database of patients (n = 14) treated with HDR brachytherapy. Various combinations of endocervical (360° or 2 × 180° output; 6 mm OD) and interstitial (180°, 270°, or 360° output; 2.4 mm OD) applicators within catheter locations from brachytherapy implants were modeled, with perfusion constant (1 or 3 kg m-3 s-1) or varying with location or temperature. Device positioning, sectoring, active length and aiming were empirically optimized to maximize thermal coverage. Conformable heating of appreciable volumes (>200 cm3) is possible using multiple sectored interstitial and endocervical ultrasound devices. The endocervical device can heat >41 °C to 4.6 cm diameter compared to 3.6 cm for the interstitial. Sectored applicators afford tight control of heating that is robust to perfusion changes in most regularly spaced configurations. T90 in example patient cases was 40.5-42.7 °C (1.9-39.6 EM43 °C) at 1 kg m-3 s-1 with 10/14 patients >=41 °C. Guidelines are presented for positioning of implant catheters during the initial surgery, selection of ultrasound applicator configurations, and tailored power schemes for achieving T90 >= 41 °C in clinically practical implant configurations. Catheter-based ultrasound devices, when adhering to the guidelines, show potential to generate conformal therapeutic heating ranging from a single endocervical device targeting small volumes local to the cervix (<2 cm radial) to a combination of a 2 × 180° endocervical and directional interstitial applicators in the lateral periphery to target much larger volumes (6 cm radial), while preferentially limiting heating of the bladder and rectum.
Lattice Location of Mg in GaN: A Fresh Look at Doping Limitations.
Wahl, U; Amorim, L M; Augustyns, V; Costa, A; David-Bosne, E; Lima, T A L; Lippertz, G; Correia, J G; da Silva, M R; Kappers, M J; Temst, K; Vantomme, A; Pereira, L M C
2017-03-03
Radioactive ^{27}Mg (t_{1/2}=9.5 min) was implanted into GaN of different doping types at CERN's ISOLDE facility and its lattice site determined via β^{-} emission channeling. Following implantations between room temperature and 800 °C, the majority of ^{27}Mg occupies the substitutional Ga sites; however, below 350 °C significant fractions were also found on interstitial positions ∼0.6 Å from ideal octahedral sites. The interstitial fraction of Mg was correlated with the GaN doping character, being highest (up to 31%) in samples doped p type with 2×10^{19} cm^{-3} stable Mg during epilayer growth, and lowest in Si-doped n-GaN, thus giving direct evidence for the amphoteric character of Mg. Implanting above 350 °C converts interstitial ^{27}Mg to substitutional Ga sites, which allows estimating the activation energy for migration of interstitial Mg as between 1.3 and 2.0 eV.
Lattice Location of Mg in GaN: A Fresh Look at Doping Limitations
NASA Astrophysics Data System (ADS)
Wahl, U.; Amorim, L. M.; Augustyns, V.; Costa, A.; David-Bosne, E.; Lima, T. A. L.; Lippertz, G.; Correia, J. G.; da Silva, M. R.; Kappers, M. J.; Temst, K.; Vantomme, A.; Pereira, L. M. C.
2017-03-01
Radioactive 27Mg (t1 /2=9.5 min ) was implanted into GaN of different doping types at CERN's ISOLDE facility and its lattice site determined via β- emission channeling. Following implantations between room temperature and 800 °C , the majority of 27Mg occupies the substitutional Ga sites; however, below 350 °C significant fractions were also found on interstitial positions ˜0.6 Å from ideal octahedral sites. The interstitial fraction of Mg was correlated with the GaN doping character, being highest (up to 31%) in samples doped p type with 2 ×1019 cm-3 stable Mg during epilayer growth, and lowest in Si-doped n -GaN, thus giving direct evidence for the amphoteric character of Mg. Implanting above 350 °C converts interstitial 27Mg to substitutional Ga sites, which allows estimating the activation energy for migration of interstitial Mg as between 1.3 and 2.0 eV.
Phosphorus-defect interactions during thermal annealing of ion implanted silicon
NASA Astrophysics Data System (ADS)
Keys, Patrick Henry
Ion implantation of dopant atoms into silicon generates nonequilibrium levels of crystal defects that can lead to the detrimental effects of transient enhanced diffusion (TED), incomplete dopant activation, and p-n junction leakage. In order to control these effects, it is vital to have a clear understanding of dopant-defect interactions and develop models that account for these interactions. This research focuses on experimentally investigating and modeling the clustering of phosphorus dopant atoms with silicon interstitials. Damage recovery of 40keV Si+ implants in phosphorus doped wells is experimentally analyzed. The effects of background phosphorus concentration, self implant dose, and anneal temperature are investigated. Phosphorus concentrations ranging from 2.0 x 1017 to 4.0 x 1019 cm-3 and Si+ doses ranging from 5.0 x 1013 cm-2 to 2.0 x 1014 cm-2 are studied during 650-800°C anneals. A dramatic reduction in the number of interstitials bound in {311} defects with increasing phosphorus background concentration is observed. It is suggested that the reduction of interstitials in {311} defects at high phosphorus concentrations is due to the formation of phosphorus-interstitial clusters (PICs). The critical concentration for clustering (approximately 1.0 x 1019 cm-3 at 750°C) is strongly temperature dependent and in close agreement with the kink concentration of phosphorus diffusion. Information gained from these "well experiments" is applied to the study of direct phosphorus implantation. An experimental study is conducted on 40keV phosphorus implanted to a dose of 1.0 x 1014 cm-2 during 650-800°C anneals. Electrically inactive PICs are shown to form at concentrations below the solid solubility limit due to high interstitial supersaturations. Data useful for developing a model to accurately predict phosphorus diffusion under nonequilibrium conditions are extracted from the experimental results. A cluster-mediated diffusion model is developed using the Florida Object Oriented Process Simulator (FLOOPS). The nucleation of defects is controlled by the diffusion-limited competition for excess interstitials between PICs and {311} clusters. The release of interstitials is driven by cluster dissolution. Modeling results show a strong correlation to those experimentally observed over a wide temporal and thermal domain using a single set of parameters. Improvements in process simulator accuracy are demonstrated with respect to dopant activation, TED, and dose loss.
Evaluation of lattice displacement in Mg - Implanted GaN by Rutherford backscattering spectroscopy
NASA Astrophysics Data System (ADS)
Nishikata, N.; Kushida, K.; Nishimura, T.; Mishima, T.; Kuriyama, K.; Nakamura, T.
2017-10-01
Evaluation of lattice displacement in Mg-ion implanted GaN is studied by combining elastic recoil detection analysis (ERDA), Rutherford backscattering spectroscopy (RBS) and Photoluminescence (PL) measurements. Mg-ion implantation into GaN single crystal wafer is performed with energies of 30 keV (ion fluence; 3.5 × 1014 cm-2) and 60 keV (6.5 × 1014 cm-2) at room temperature. The ERDA measurements using the 1.5 MeV helium beam can evaluate hydrogen from the surface to ∼300 nm. The hydrogen concentration for un-implanted and as-implanted GaN is 3.1 × 1014 cm-2 and 6.1 × 1014 cm-2 at around 265 nm in depth. χmin (the ratio of aligned and random yields) near the surface of the 〈0 0 0 1〉 direction for Ga is 1.61% for un-implanted and 2.51% for Mg-ion implanted samples. On the other hand, the value of χmin for N is 10.08% for un-implanted and 11.20% for Mg-ion implanted samples. The displacement concentration of Ga and N estimated from these χmin values is 4.01 × 1020 cm-3 and 5.46 × 1020 cm-3, respectively. This suggests that Ga vacancy (VGa), N vacancy (VN), Ga interstitial (Gai), and N interstitial (Ni) is introduced in Mg-ion implanted GaN. A strong emission at around 400 nm in as-implanted GaN is related to a VN donor and some acceptor pairs. It is suggested that the origin of the very high resistivity after the Mg-ion implantation is attributed to the carrier compensation effect due to the deep level of Ni as a non-radiative center.
Corrosion analysis of NiCu and PdCo thermal seed alloys used as interstitial hyperthermia implants.
Paulus, J A; Parida, G R; Tucker, R D; Park, J B
1997-12-01
Ferromagnetic materials with low Curie temperatures are being investigated for use as interstitial implants for fractionated hyperthermia treatment of prostatic disease. Previous investigations of the system have utilized alloys, such as NiCu, with inadequate corrosion resistance, requiring the use of catheters for removal of the implants following treatment or inert surface coatings which may interfere with thermal characteristics of the implants. We are evaluating a palladium-cobalt (PdCo) binary alloy which is very similar to high palladium alloys used in dentistry. Electrochemical corrosion tests and immersion tests at 37 degrees C for both NiCu and PdCo alloy samples in mammalian Ringer's solution were performed. Long-term corrosion rates are 5.8 x 10(-5) microm per year (NiCu) and 7.7 x 10(-8) microm per year (PdCo) from average immersion test results, indicating higher corrosion resistance of PdCo (P < 0.02); immersion corrosion rates were much lower than initial corrosion rates found electrochemically. Both alloys had significantly lower corrosion rates than standard surgical implant rates of 0.04 microm per year (P < 0.001 for both alloys). Scanning electron microscopy illustrates changes in the NiCu alloy surface due to pitting corrosion; no difference is observed for PdCo. The data indicate that the PdCo alloy may be suitable as a long-term implant for use in fractionated hyperthermia.
Skugareva, O A; Kaplan, M A; Malygina, A I; Mikhailovskaya, A A
2009-11-01
Antitumor efficiency of interstitial photodynamic therapy was evaluated in experiments on outbred albino rats with implanted M-1 sarcoma. Interstitial photodynamic therapy was carried out using one diffusor at different output power and duration of exposure. The percentage of complete regression of the tumors increased with increasing exposure parameters.
NASA Astrophysics Data System (ADS)
Mori, Takahiro; Morita, Yukinori; Matsukawa, Takashi
2018-05-01
The effect of post-implantation annealing (PIA) on Al-N isoelectronic trap (IET) formation in silicon has been experimentally investigated to discuss the Al-N IET formation and implantation-induced defect recovery mechanisms. We performed a photoluminescence study, which indicated that self-interstitial clusters and accompanying vacancies are generated in the ion implantation process. It is supposed that Al and N atoms move to the vacancy sites and form stable Al-N pairs in the PIA process. Furthermore, the PIA process recovers self-interstitial clusters while transforming their atomic configuration. The critical temperature for the formation/dissociation of Al-N pairs was found to be 450 °C, with which we describe the process integration for devices utilizing Al-N IET technology.
Intrinsic point-defect balance in self-ion-implanted ZnO.
Neuvonen, Pekka T; Vines, Lasse; Svensson, Bengt G; Kuznetsov, Andrej Yu
2013-01-04
The role of excess intrinsic atoms for residual point defect balance has been discriminated by implanting Zn or O ions into Li-containing ZnO and monitoring Li redistribution and electrical resistivity after postimplant anneals. Strongly Li-depleted regions were detected in the Zn-implanted samples at depths beyond the projected range (R(p)) upon annealing ≥ 600 °C, correlating with a resistivity decrease. In contrast, similar anneals of the O-implanted samples resulted in Li accumulation at R(p) and an increased resistivity. Control samples implanted with Ar or Ne ions, yielding similar defect production as for the Zn or O implants but with no surplus of intrinsic atoms, revealed no Li depletion. Thus, the depletion of Li shows evidence of excess Zn interstitials (Zn(I)) being released during annealing of the Zn-implanted samples. These Zn(I)'s convert substitutional Li atoms (Li(Zn)) into highly mobile interstitial ones leading to the strongly Li-depleted regions. In the O-implanted samples, the high resistivity provides evidence of stable O(I)-related acceptors.
Possible cage motion of interstitial Fe in α-Al 2 O 3
NASA Astrophysics Data System (ADS)
Gunnlaugsson, H. P.; Johnston, K.; Masenda, H.; Mantovan, R.; Mølholt, T. E.; Bharuth-Ram, K.; Gislason, H. P.; Langouche, G.; Madsen, M. B.; Naidoo, D.; Ólafsson, S.; Weyer, G.
2013-04-01
In addition to spectral components due to Fe2 + and Fe3 + , a single line is observed in emission Mössbauer spectra following low fluence (<1015 cm - 2) implantation of 57Fe*, 57Mn and 57Co in α-Al2O3. For the 57Co and 57Mn implantations, the intensity of the single line is found to depend on the emission angle relative to the crystal symmetry axis. This angular dependence can be explained by a non-isotropic f-factor and/or motion of the Fe ion between sites in an interstitial cage. It is argued that interstitial cage motion is a more likely explanation, as this can account for the lack of quadrupole splitting of the line.
Changes in the interstitial fluid and the muscle water in rabbits in hemorrhagic shock.
Wolcott, M W; Malinin, T I; Wu, N M
1976-01-01
Dynamics and changes in the biochemical composition in the interstitial fluid and the muscle water were studied in hemorrhagic shock. The interstitial fluid was collected from implanted perforated capsules. Muscle biopsies were examined with regard to their water content by the steady state magnetic nuclear resonance spectroscopy. The consistent and what appears to be the most significant changes were the fall in the interstitial fluid pressures, the quantitative reduction of muscle water, a sharp fall in the blood and interstitial blood pH, the moderate hyperkalemia and lack of change in blood an interstitial fluid sodium, and the rise in blood glucose levels not accompanied by a rise in the interstitial fluid glucose levels. PMID:11754
Optical properties of P ion implanted ZnO
NASA Astrophysics Data System (ADS)
Pong, Bao-Jen; Chou, Bo-Wei; Pan, Ching-Jen; Tsao, Fu-Chun; Chi, Gou-Chung
2006-02-01
Red and green emissions are observed from P ion implanted ZnO. Red emission at ~680 nm (1.82 eV) is associated with the donor-acceptor pair (DAP) transition, where the corresponding donor and acceptor are interstitial zinc (Zn i) and interstitial oxygen (O i), respectively. Green emission at ~ 516 nm (2.40 eV) is associated with the transition between the conduction band and antisite oxygen (O Zn). Green emission at ~516nm (2.403 eV) was observed for ZnO annealed at 800 oC under ambient oxygen, whereas, it was not visible when it was annealed in ambient nitrogen. Hence, the green emission is most likely not related to oxygen vacancies on ZnO sample, which might be related to the cleanliness of ZnO surface, a detailed study is in progress. The observed micro-strain is larger for N ion implanted ZnO than that for P ion implanted ZnO. It is attributed to the larger straggle of N ion implanted ZnO than that of P ion implanted ZnO. Similar phenomenon is also observed in Be and Mg ion implanted GaN.
NASA Astrophysics Data System (ADS)
Hoskin, HLD; Furie, E.; Collins, W.; Ganey, TM; Schlatterer, DR
2017-05-01
Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C and O are used as stabilizers that help raise the temperature at which titanium can be cast. Since the presence of stabilizers reduces ductility and fatigue strength, all interstitial elements are removed after casting. Considering this, the presence of C and O suggests that not all of the interstitials were removed during the manufacturing process, resulting in decreased fatigue strength. Further destructive analytical testing would verify weld quality and failure mode. RTSSs are quite successful in select patients not amenable to traditional shoulder arthroplasty options. This case report highlights how an implant may function well for several years and then suddenly fail without warning. SEM and EDS analysis suggest that residual C and O in the taper lowered the metal implant’s integrity, leading to torsional cracking at the weld junction of the humeral tray and the taper. The elevated levels of C and O measured at fracture sites on both the tray and the taper suggest poor quality filler metal or failure to remove all interstitial elements after casting. In both cases, the results would be decreased fatigue strength and overall toughness, leading to mechanical failure. A manufacturer’s recall of all implants soon followed the reporting of this implant failure; subsequently, the metal materials were changed from Ti6Al4V to both titanium alloy and cobalt-chrome alloy (Co-Cr-Mo). Time will tell if the alterations were sufficient.
Oxygen-related vacancy-type defects in ion-implanted silicon
NASA Astrophysics Data System (ADS)
Pi, X. D.; Burrows, C. P.; Coleman, P. G.; Gwilliam, R. M.; Sealy, B. J.
2003-10-01
Czochralski silicon samples implanted to a dose of 5 × 1015 cm-2 with 0.5 MeV O and to a dose of 1016 cm-2 with 1 MeV Si, respectively, have been studied by positron annihilation spectroscopy. The evolution of divacancies to vacancy (V)-O complexes is out-competed by V-interstitial (I) recombination at 400 and 500 °C in the Si- and O-implanted samples; the higher oxygen concentration makes the latter temperature higher. The defective region shrinks as the annealing temperature increases as interstitials are injected from the end of the implantation range (Rp). VmOn (m> n) are formed in the shallow region most effectively at 700 °C for both Si and O implantation. VxOy (x< y) are produced near Rp by the annealing. At 800 °C, implanted Si ions diffuse and reduce m and implanted O ions diffuse and increase n in VmOn. All oxygen-related vacancy-type defects appear to begin to dissociate at 950 °C, with the probable formation of oxygen clusters. At 1100 °C, oxygen precipitates appear to form just before Rp in O-implanted silicon.
Direct evidence of the recombination of silicon interstitial atoms at the silicon surface
NASA Astrophysics Data System (ADS)
Lamrani, Y.; Cristiano, F.; Colombeau, B.; Scheid, E.; Calvo, P.; Schäfer, H.; Claverie, Alain
2004-02-01
In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si + ions to a dose of 2 × 10 14 ions/cm 2 and annealed at 850 °C for several times in an RTA system in flowing N 2. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si ints supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 °C in a N 2 ambient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, William, E-mail: william.hsu@utexas.edu; Kim, Taegon; Chou, Harry
2016-07-07
Although the diffusion control and dopant activation of Ge p-type junctions are straightforward when using B{sup +} implantation, the use of the heavier BF{sub 2}{sup +} ions or even BF{sup +} is still favored in terms of shallow junction formation and throughput—because implants can be done at higher energies, which can give higher beam currents and beam stability—and thus the understanding of the effect of F co-doping becomes important. In this work, we have investigated diffusion and end-of-range (EOR) defect formation for B{sup +}, BF{sup +}, and BF{sub 2}{sup +} implants in crystalline and pre-amorphized Ge, employing rapid thermal annealingmore » at 600 °C and 800 °C for 10 s. It is demonstrated that the diffusion of B is strongly influenced by the temperature, the presence of F, and the depth of amorphous/crystalline interface. The B and F diffusion profiles suggest the formation of B–F complexes and enhanced diffusion by interaction with point defects. In addition, the strong chemical effect of F is found only for B in Ge, while such an effect is vanishingly small for samples implanted with F alone, or co-implanted with P and F, as evidenced by the high residual F concentration in the B-doped samples after annealing. After 600 °C annealing for 10 s, interstitial-induced compressive strain was still observed in the EOR region for the sample implanted with BF{sup +}, as measured by X-ray diffraction. Further analysis by cross-sectional transmission electron microscopy showed that the {311} interstitial clusters are the majority type of EOR defects. The impact of these {311} defects on the electrical performance of Ge p{sup +}/n junctions formed by BF{sup +} implantation was evaluated.« less
NASA Astrophysics Data System (ADS)
Mølholt, T. E.; Mantovan, R.; Gunnlaugsson, H. P.; Svane, A.; Masenda, H.; Naidoo, D.; Bharuth-Ram, K.; Fanciulli, M.; Gislason, H. P.; Johnston, K.; Langouche, G.; Ólafsson, S.; Sielemann, R.; Weyer, G.
2014-01-01
Isolated 57Fe atoms were studied in MgO single-crystals by emission Mössbauer spectroscopy following implantation of 57Mn decaying to 57Fe. Four Mössbauer spectral components were found corresponding to different Fe lattice positions and/or charge states. Two components represent Fe atoms substituting Mg as Fe2+ and Fe3+, respectively; a third component is due to Fe in a strongly implantation-induced disturbed region. The fourth component, which is the focus of this paper, can be assigned to Fe at an interstitial site. Comparison of its measured isomer shift with ab initio calculations suggests that the interstitial Fe is located on, or close to, the face of the rock-salt MgO structure. To harmonize such an assignment with the measured near-zero quadrupole interaction a local motion process (cage motion) of the Fe has to be stipulated. The relation of such a local motion as a starting point for long range diffusion is discussed.
Persistent photoconductivity in oxygen-ion implanted KNbO3 bulk single crystal
NASA Astrophysics Data System (ADS)
Tsuruoka, R.; Shinkawa, A.; Nishimura, T.; Tanuma, C.; Kuriyama, K.; Kushida, K.
2016-12-01
Persistent Photoconductivity (PPC) in oxygen-ion implanted KNbO3 ([001] oriented bulk single crystals; perovskite structure; ferroelectric with a band gap of 3.16 eV) is studied in air at room temperature to prevent the degradation of its crystallinity caused by the phase transition. The residual hydrogens in un-implanted samples are estimated to be 5×1014 cm-2 from elastic recoil detection analysis (ERDA). A multiple-energy implantation of oxygen ions into KNbO3 is performed using energies of 200, 400, and 600 keV (each ion fluence:1.0×1014 cm-2). The sheet resistance varies from >108 Ω/□ for an un-implanted sample to 1.9×107 Ω/□ for as-implanted one, suggesting the formation of donors due to hydrogen interstitials and oxygen vacancies introduced by the ion implantation. The PPC is clearly observed with ultraviolet and blue LEDs illumination rather than green, red, and infrared, suggesting the release of electrons from the metastable conductive state below the conduction band relating to the charge states of the oxygen vacancy.
A Wsbnd Ne interatomic potential for simulation of neon implantation in tungsten
NASA Astrophysics Data System (ADS)
Backman, Marie; Juslin, Niklas; Huang, Guiyang; Wirth, Brian D.
2016-08-01
An interatomic pair potential for Wsbnd Ne is developed for atomistic molecular dynamics simulations of neon implantation in tungsten. The new potential predicts point defect energies and binding energies of small clusters that are in good agreement with electronic structure calculations. Molecular dynamics simulations of small neon clusters in tungsten show that trap mutation, in which an interstitial neon cluster displaces a tungsten atom from its lattice site, occurs for clusters of three or more neon atoms. However, near a free surface, trap mutation can occur at smaller sizes, including even a single neon interstitial in close proximity to a (100) or (110) surface.
Effect of reversal of double-implantation schedule of boron in mercury cadmium telluride
NASA Astrophysics Data System (ADS)
Kumar, Rakesh; Dutt, M. B.; Nath, R.; Gopal, Vishnu; Khosla, Y. P.; Sharma, K. K.
1992-02-01
Radiation damage due to B+ ion implantation in p-type HgCdTe has been found to create Hg interstitials giving rise to n-type conversion. The implantation energies were kept at 50 and 100 keV with a dose of 1 X 1013 cm-2 each. The effect of implantation with ascending and descending orders of energies were found to be quite different from each other. Radiation enhanced diffusion is thought to be responsible for this anomaly.
Interstitial therapy of perineal and gynecological malignancies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, A.; Herstein, P.; Portnuff, J.
1983-03-01
Thirty-five patients, 38 to 88 years of age, were treated with 125-Iodine or 192-Iridium interstitial implants at Stanford University Medical Center between July 1974, and December, 1978. There were 25 primary epithelial malignancies, eight extensions from intrapelvic organs and two metastatic tumors (hypernephroma and Hodgkin's disease). The involved sites were: urethra (6 patients); vulva (9 patients); vagina (8 patients); anus (7 patients); cervix (5 patients). Implantation was usually performed to treat evident or microscopic disease in conjunction with external beam pelvic treatment with or without local excision. Computerized implant preplanning was used.125-Iodine seeds were inserted either directly or within absorbablemore » suture Polyglactin 910; 192-Iridium in nylon carriers was placed by suture or transperineal template. Two patients were lost to follow-up leaving 33 patients, 27 of whom are alive and free of local disease from 37 to 76 months. The overall local control rate was 88%, or 29/33 patients. All four local recurrences appeared before 24 months. Minor complications included: 10 patients with transient mucositis, four with superficial ulcers, and one patient with infection at the implanted site. Two major complications occurred: a necrotic rectal ulcer requiring a colostomy and a contracted, painful bladder necessitating a urinary diversion. It is concluded that in selected cases interstitial irradiation provides good local control of perineal and gynecological malignancies with low morbidity in this elderly and quite often fragile group of patients.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrof, Julian; Müller, Ralph; Reedy, Robert C.
2015-07-28
Boron diffusivity reduction in extrinsically doped silicon was investigated in the context of a process combination consisting of BBr3 furnace diffusion and preceding Phosphorus ion implantation. The implantation of Phosphorus leads to a substantial blocking of Boron during the subsequent Boron diffusion. First, the influences of ion implantation induced point defects as well as the initial P doping on B diffusivity were studied independently. Here, it was found that not the defects created during ion implantation but the P doping itself results in the observed B diffusion retardation. The influence of the initial P concentration was investigated in more detailmore » by varying the P implantation dose. A secondary ion mass spectrometry (SIMS) analysis of the BSG layer after the B diffusion revealed that the B diffusion retardation is not due to potential P content in the BSG layer but rather caused by the n-type doping of the crystalline silicon itself. Based on the observations the B diffusion retardation was classified into three groups: (i) no reduction of B diffusivity, (ii) reduced B diffusivity, and (iii) blocking of the B diffusion. The retardation of B diffusion can well be explained by the phosphorus doping level resulting in a Fermi level shift and pairing of B and P ions, both reducing the B diffusivity. Besides these main influences, there are probably additional transient phenomena responsible for the blocking of boron. Those might be an interstitial transport mechanism caused by P diffusion that reduces interstitial concentration at the surface or the silicon/BSG interface shift due to oxidation during the BBr3 diffusion process. Lifetime measurements revealed that the residual (non-blocked) B leads to an increased dark saturation current density in the P doped region. Nevertheless, electrical quality is on a high level and was further increased by reducing the B dose as well as by removing the first few nanometers of the silicon surface after the BBr3 diffusion« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oliviero, E.; David, M. L.; Beaufort, M. F.
The crystalline-to-amorphous transformation induced by lithium ion implantation at low temperature has been investigated. The resulting damage structure and its thermal evolution have been studied by a combination of Rutherford backscattering spectroscopy channelling (RBS/C) and cross sectional transmission electron microscopy (XTEM). Lithium low-fluence implantation at liquid nitrogen temperature is shown to produce a three layers structure: an amorphous layer surrounded by two highly damaged layers. A thermal treatment at 400 Degree-Sign C leads to the formation of a sharp amorphous/crystalline interfacial transition and defect annihilation of the front heavily damaged layer. After 600 Degree-Sign C annealing, complete recrystallization takes placemore » and no extended defects are left. Anomalous recrystallization rate is observed with different motion velocities of the a/c interfaces and is ascribed to lithium acting as a surfactant. Moreover, the sharp buried amorphous layer is shown to be an efficient sink for interstitials impeding interstitial supersaturation and {l_brace}311{r_brace} defect formation in case of subsequent neon implantation. This study shows that lithium implantation at liquid nitrogen temperature can be suitable to form a sharp buried amorphous layer with a well-defined crystalline front layer, thus having potential applications for defects engineering in the improvement of post-implantation layers quality and for shallow junction formation.« less
Zn precipitation and Li depletion in Zn implanted ZnO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, K. S.; Jagadish, C.; Wong-Leung, J., E-mail: jenny.wongleung@anu.edu.au
2016-07-11
Ion implantation of Zn substituting elements in ZnO has been shown to result in a dramatic Li depletion of several microns in hydrothermally grown ZnO. This has been ascribed to a burst of mobile Zn interstials. In this study, we seek to understand the reason behind this interstitial mediated transient enhanced diffusion in Li-containing ZnO samples after Zn implantation. ZnO wafers were implanted with Zn to two doses, 5 × 10{sup 15} cm{sup −2} and 1 × 10{sup 17} cm{sup −2}. Secondary ion mass spectrometry was carried out to profile the Li depletion depth for different annealing temperatures between 600 and 800 °C. The 800 °C annealing hadmore » the most significant Li depletion of close to 60 μm. Transmission electron microscopy (TEM) was carried out in selected samples to identify the reason behind the Li depletion. In particular, TEM investigations of samples annealed at 750 °C show significant Zn precipitation just below the depth of the projected range of the implanted ions. We propose that the Zn precipitation is indicative of Zn supersaturation. Both the Li depletion and Zn precipitation are competing synchronous processes aimed at reducing the excess Zn interstitials.« less
Interstitial and external radiotherapy in carcinoma of the soft palate and uvula
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esche, B.A.; Haie, C.M.; Gerbaulet, A.P.
1988-09-01
Forty-three patients, all male, with limited epidermoid carcinoma of the soft palate and uvula were treated by interstitial implant usually associated with external radiotherapy. Most patients received 50 Gy external irradiation to the oropharynx and neck followed by 20-35 Gy by interstitial iridium-192 wires using either guide gutters or a plastic tube technique. Twelve primary tumors and two recurrences after external irradiation alone had implant only for 65-75 Gy. Total actuarial local control is 92% with no local failures in 34 T1 primary tumors. Only one serious complication was seen. Overall actuarial survival was 60% at 3 years and 37%more » at 5 years but cause-specific survivals were 81% and 64%. The leading cause of death was other aerodigestive cancer, with an actuarial rate of occurrence of 10% per year after treatment of a soft palate cancer. Interstitital brachytherapy alone or combined with external irradiation is safe, effective management for early carcinoma of the soft palate and uvula but second malignancy is a serious problem.« less
Hamers, H P; Johansson, K A; Venselaar, J L; de Brouwer, P; Hansson, U; Moudi, C
1993-01-01
Two anthropomorphic phantom breasts and six patients with breast carcinoma were irradiated according the prescriptions of the EORTC protocol 22881 on the conservative management of breast carcinoma by tumorectomy and radiotherapy. During the implantation procedure for an iridium-192 boost, three tubes were implanted, enabling the measurement with TLD rods of the dose within the breasts of the phantom and the patients during one fraction of the external x-ray therapy and during the interstitial therapy. Measured doses were compared with calculated values from a 2-D dose planning system. In general a fair agreement was found between the measured and calculated doses in points within the breast for the external beam therapy as well as for the interstitial treatment.
Retreatment of recurrent carcinoma of the head and neck by afterloading interstitial 192Ir implant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Emami, B.; Marks, J.E.
From January 1975 to December 1980, 25 patients with persistent or recurrent carcinomas of the head and neck were retreated for palliation at the Division of Radiation Oncology, Mallinckrodt Institute of Radiology. These patients had all undergone extensive previous treatment by surgery and/or radiation. All were retreated with 192Ir interstitial implant with or without external radiation and/or surgical excision. Of 25 patients, 13 had complete response (CR) and 6 had partial response for a follow-up period of 1 to 7 years. Of 13 patients with CR, 6 are alive with no evidence of disease (NED) and two died NED. Detailedmore » results are presented and the new strategy for such patients is discussed.« less
Chi, A; Gao, M; Nguyen, N P; Albuquerque, K
2009-06-01
This study investigates the technical feasibility of pre-implant image-based treatment planning for LDR GYN interstitial brachytherapy(IB) based on the GEC-ESTRO guidelines. Initially, a virtual plan is generated based on the prescription dose and GEC-ESTRO defined OAR dose constraints with a pre-implant CT. After the actual implant, a regular diagnostic CT was obtained and fused with our pre-implant scan/initial treatment plan in our planning software. The Flexi-needle position changes, and treatment plan modifications were made if needed. Dose values were normalized to equivalent doses in 2 Gy fractions (LQED 2 Gy) derived from the linear-quadratic model with alpha/beta of 3 for late responding tissues and alpha/beta of 10 for early responding tissues. D(90) to the CTV, which was gross tumor (GTV) at the time of brachytherapy with a margin to count for microscopic disease, was 84.7 +/- 4.9% of the prescribed dose. The OAR doses were evaluated by D(2cc) (EBRT+IB). Mean D(2cc) values (LQED(2Gy)) for the rectum, bladder, sigmoid, and small bowel were the following: 63.7 +/- 8.4 Gy, 61.2 +/- 6.9 Gy, 48.0 +/- 3.5 Gy, and 49.9 +/- 4.2 Gy. This study confirms the feasibility of applying the GEC-ESTRO recommended dose parameters in pre-implant CT-based treatment planning in GYN IB. In the process, this pre-implant technique also demonstrates a good approximation of the target volume dose coverage, and doses to the OARs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrof, Julian, E-mail: julian.schrof@ise.fraunhofer.de; Müller, Ralph; Benick, Jan
2015-07-28
Boron diffusivity reduction in extrinsically doped silicon was investigated in the context of a process combination consisting of BBr{sub 3} furnace diffusion and preceding Phosphorus ion implantation. The implantation of Phosphorus leads to a substantial blocking of Boron during the subsequent Boron diffusion. First, the influences of ion implantation induced point defects as well as the initial P doping on B diffusivity were studied independently. Here, it was found that not the defects created during ion implantation but the P doping itself results in the observed B diffusion retardation. The influence of the initial P concentration was investigated in moremore » detail by varying the P implantation dose. A secondary ion mass spectrometry (SIMS) analysis of the BSG layer after the B diffusion revealed that the B diffusion retardation is not due to potential P content in the BSG layer but rather caused by the n-type doping of the crystalline silicon itself. Based on the observations the B diffusion retardation was classified into three groups: (i) no reduction of B diffusivity, (ii) reduced B diffusivity, and (iii) blocking of the B diffusion. The retardation of B diffusion can well be explained by the phosphorus doping level resulting in a Fermi level shift and pairing of B and P ions, both reducing the B diffusivity. Besides these main influences, there are probably additional transient phenomena responsible for the blocking of boron. Those might be an interstitial transport mechanism caused by P diffusion that reduces interstitial concentration at the surface or the silicon/BSG interface shift due to oxidation during the BBr{sub 3} diffusion process. Lifetime measurements revealed that the residual (non-blocked) B leads to an increased dark saturation current density in the P doped region. Nevertheless, electrical quality is on a high level and was further increased by reducing the B dose as well as by removing the first few nanometers of the silicon surface after the BBr{sub 3} diffusion.« less
Lithification opf gas-rich chondrite regolith breccias by grain boundary and localized shock melting
NASA Technical Reports Server (NTRS)
Bischoff, A.; Rubin, A. E.; Keil, K.; Stoeffler, D.
1983-01-01
The fine-grained matrices (less than 150 microns) of 14 gas-rich ordinary chondrile regolith breccias were studied in an attempt to decipher the nature of the lithification process that converted loose regolith material into consolidated breccias. It is found that there is a continuouos gradation in matrix textures from nearly completely clastic (class A) to highly cemented (class C) breccias in which the remining clasts are completely surrounded by interstitial, shock-melted material. It is concluded that this interstitial material is formed by shock melting in the porous regolith. In general, the abundances of solar-wind-implanted He-4 and Ne-20 are inversely correlated with the abundance of intenstitial, shock-melted, feldspathic material. Chondrites with the highest abundance of interstitial, melted material (class C) experienced the highest shock pressures and temperatures and suffered the most extensive degassing. It is this interstitial, feldspathic melt that lithifies and cements the breccias together; those breccias with very little interstitial melt (class A) are the most porous and least consolidated.
Safety and accuracy of a new long-term subconjunctival glucose sensor.
Hasslacher, Christoph; Auffarth, Gerd; Platten, Isabell; Rabsilber, Tanja; Smith, Beate; Kulozik, Felix; Knuth, Monika; Nikolaus, Katharina; Müller, Achim
2012-09-01
A new biosensor has been developed by EyeSense (Großostheim, Germany) that is placed into the conjunctiva of one eye to measure the glucose concentration of the surrounding tissue in a non-invasive manner. In the present study we investigated the correlation between glucose concentrations measured by the EyeSense implant and those determined by finger prick testing, as well as the tolerability and safety of the implant over a 16-week period. The study was performed in 28 diabetic patients. The biosensor was inserted under local anesthesia and sterile conditions. Correlations between capillary glucose measured by laboratory methods and interstitial glucose determined by the biosensor were investigated by inducing increases and decreases in glucose values between 60 and 300 mg/dL. Most patients experienced a mild subconjunctival hemorrhage postoperatively. Except for the minor sensation of the presence of foreign body, the implants were well tolerated. Three patients lost the ocular mini insert spontaneously, whereas there was a function failure of the insert in four patients. Error grid analysis showed that the percentage of data pairs in the acceptable ranges (zone A and B) was very high (>96%). However, there was a shift from zone A to zone B during observation. This was due primarily to an increase in the lag time between capillary and interstitial measured glucose. he present study demonstrates good tolerability and measurement performance of the biosensor. The reasons for an increase in the lag time are still unknown; local reactions may be involved. © 2012 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
Technique of after-loading interstitial implants.
Syed, A M; Feder, B H
1977-01-01
Interstitial implants are either removable or permanent (and occasionally a combination of both). Permanent implants are generally utilized where tumors are not accessible enough to permit easy removal of sources or where accurate source distribution is less critical. They are useful for cancers of the lung, pancreas, prostate, bladder, lymph nodes, etc. Radon and gold-198 have been largely replaced by iodine-125. Our major interests are in the removable after-loading iridium-192 implant techniques. Template (steel guide) and non-template (plastic tube) techniques are utilized. Templates are preferred where the tumor volume can only be approached from one side and where accurate positioning of sources would otherwise be difficult. They are useful for cancers of the cervix, vagina, urethra, and rectum. Non-template (plastic tube) techniques are preferred where the tumor volume can be approached from at least two sides and where templates are either not feasible or not essential for accurate positioning of sources. The single needle non-template approach is useful for cancers of lip, nodes, and breast (plastic button) and for cancers of the oral cavity and oropharynx (gold button). The paired needle non-template approach is useful for cancers of the gum, retromolar trigone, and base of tongue (loop technique) and for cancers of the palate (arch technique). Procedures for each technique are described in detail.
Effect of dose and size on defect engineering in carbon cluster implanted silicon wafers
NASA Astrophysics Data System (ADS)
Okuyama, Ryosuke; Masada, Ayumi; Shigematsu, Satoshi; Kadono, Takeshi; Hirose, Ryo; Koga, Yoshihiro; Okuda, Hidehiko; Kurita, Kazunari
2018-01-01
Carbon-cluster-ion-implanted defects were investigated by high-resolution cross-sectional transmission electron microscopy toward achieving high-performance CMOS image sensors. We revealed that implantation damage formation in the silicon wafer bulk significantly differs between carbon-cluster and monomer ions after implantation. After epitaxial growth, small and large defects were observed in the implanted region of carbon clusters. The electron diffraction pattern of both small and large defects exhibits that from bulk crystalline silicon in the implanted region. On the one hand, we assumed that the silicon carbide structure was not formed in the implanted region, and small defects formed because of the complex of carbon and interstitial silicon. On the other hand, large defects were hypothesized to originate from the recrystallization of the amorphous layer formed by high-dose carbon-cluster implantation. These defects are considered to contribute to the powerful gettering capability required for high-performance CMOS image sensors.
Minimally invasive ultrasound thermal therapy with MR thermal monitoring and guidance
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Stafford, R. Jason; Price, Roger E.; Nau, William H.; Tyreus, Per Daniel; Rivera, Belinda; Schomer, Donald; Olsson, Lars; Hazle, John D.
2001-06-01
In this study both transurethral and interstitial ultrasound thermal therapy were applied to thermally coagulate targeted portions of the canine prostate or brain and implanted TVT tumors while using MRI-based thermal mapping techniques to monitor the therapy. MRI was also used for target definition, positioning of the applicator, and evaluation of target viability post-therapy. The complex phase-difference mapping technique using an iGE-EPI sequence with lipid suppression was used for determining temperature elevations within the in vivo prostate or brain and surrounding structures. Calculated temperature distributions, thermal dose exposures, T2-wieghted & T1-contrast enhanced images, gross inspection, and histology of sectioned prostates and brains were in good agreement with each other in defining destroyed tissue zones. Interstitial and transurethral ultrasound applicators produce directed zones of thermal coagulation within targeted tissue and implanted tumor, which can be accurately monitored and evaluated by MRI.
Neuro-oncology update: radiation safety and nursing care during interstitial brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randall, T.M.; Drake, D.K.; Sewchand, W.
Radiation control and safety are major considerations for nursing personnel during the care of patients receiving brachytherapy. Since the theory and practice of radiation applications are not part of the routine curriculum of nursing programs, the education of nurses and other health care professionals in radiation safety procedures is important. Regulatory agencies recommend that an annual safety course be given to all persons frequenting, using, or associated with patients containing radioactive materials. This article presents pertinent aspects of the principles and procedures of radiation safety, the role of personnel dose-monitoring devices, and the value of additional radiation control features, suchmore » as a lead cubicle, during interstitial brain implants. One institution's protocol and procedures for the care of high-intensity iridium-192 brain implants are discussed. Preoperative teaching guidelines and nursing interventions included in the protocol focus on radiation control principles.« less
Krempien, Robert; Hoppe, Harald; Kahrs, Lüder; Daeuber, Sascha; Schorr, Oliver; Eggers, Georg; Bischof, Marc; Munter, Marc W; Debus, Juergen; Harms, Wolfgang
2008-03-01
The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.
Lauten, Alexander; Laube, Adrian; Schubert, Harald; Bischoff, Sabine; Nietzsche, Sandor; Horstkötter, Kim; Poudel-Bochmann, Bhawana; Franz, Marcus; Lichtenberg, Artur; Figulla, Hans R; Akhyari, Payam
2015-01-01
Caval valve implantation has been suggested for transcatheter treatment of severe tricuspid regurgitation (TR). Combining the interventional technique with the promising surgical experience with decellularized valves, we sought to evaluate the functional and structural outcome of decellularized pericardial tissue valves (dTVs) in the low-pressure venous circulation in a chronic model of TR. Sixteen pericardial tissue valves were heterotopically implanted in the inferior and superior vena cava in a sheep model (54-98 kg; median 74.5 kg, n = 8) of severe TR. The devices were assembled using self-expanding nitinol stents and bovine pericardia decellularized by a detergent-based protocol (group dTV; n = 8). Glutaraldehyde-fixed pericardial tissue valves served as control (GaTV, n = 8). After 6 months, device function and structural maturation were analyzed using echocardiographic, histologic, immunohistologic, and electron microscopic approaches. After implantation, cardiac output increased significantly from 3.7 ± 1.1 l/min to 4.8 ± 1.1 l/min (P < 0.05) and competent valve function was verified by angiography. At 6 months, angiographic and echocardiographic evaluation revealed moderate to severe regurgitation in all GaTV. In contrast, five of the eight dTVs functioned well with only minor regurgitation. In these animals, autopsy revealed preserved valve structure with tender leaflets without signs of thrombosis or calcification. Conversely, GaTV showed severe degeneration with large calcification areas. Microscopic and histologic analysis confirmed endothelial repopulation in both valve types. However, additional interstitial reseeding was observed in decellularized valves. In the venous circulation in severe TR, decellularized valves show superior functional performance compared to Ga-fixed tissue valves. Macroscopic and microscopic analyses suggest preserved structural integrity and advanced endothelial and interstitial repopulation with evidence of less degradation in dTV. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Ma, Changdong; Lu, Fei; Xu, Bo; Fan, Ranran
2016-05-01
We investigated lattice modification and its physical mechanism in H and He co-implanted, z-cut potassium titanyl phosphate (KTiOPO4). The samples were implanted with 110 keV H and 190 keV He, both to a fluence of 4 × 1016 cm-2, at room temperature. Rutherford backscattering/channeling, high-resolution x-ray diffraction, and transmission electron microscopy were used to examine the implantation-induced structural changes and strain. Experimental and simulated x-ray diffraction results show that the strain in the implanted KTiOPO4 crystal is caused by interstitial atoms. The strain and stress are anisotropic and depend on the crystal's orientation. Transmission electron microscopy studies indicate that ion implantation produces many dislocations in the as-implanted samples. Annealing can induce ion aggregation to form nanobubbles, but plastic deformation and ion out-diffusion prevent the KTiOPO4 surface from blistering.
Integrated external and interstitial radiation therapy for primary carcinoma of the vagina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puthawala, A.; Syed, A.M.; Nalick, R.
1983-09-01
Twenty-seven patients with the diagnosis of primary carcinoma of the vagina were treated by definitive radiotherapy. Twenty-three patients received a combination of external and interstitial iridium-192 implant irradiation and four patients received only interstitial irradiation. Twenty-one patients had squamous cell carcinoma and six had adenocarcinoma. All patients were staged according to the FIGO classification. More than 70% of patients had relatively advanced local disease and conventional intracavitary irradiation was unsuitable. Local tumor control was observed in 85% (23 of 27 patients), and 56% of the patients remain alive and free of disease for a median follow-up period of 50 monthsmore » to a maximum follow-up period of 84 months. Fifteen percent of the patients suffered from treatment-related complications.« less
An overview of interstitial brachytherapy and hyperthermia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandt, B.B.; Harney, J.
Interstitial thermoradiotherapy, an experimental cancer treatment that combines interstitial radiation implants (brachytherapy) and interstitial hyperthermia, is in the early stages of investigation. In accordance with the procedure used in a current national trial protocol, a 60-minute hyperthermia treatment is administered after catheters are placed into the tumor area while the patient is under general anesthesia. This is immediately followed by loading of radioactive Iridium-192 seeds into the catheters for a defined period of time. Once the prescribed radiation dose is delivered, the radioactive sources are removed and a second, 60-minute hyperthermia treatment is administered. Clinical trials with hyperthermia in combinationmore » with radiation have increased in recent years. Nurses caring for these patients need to become more knowledgeable about this investigational therapy. This paper provides an overview of the biologic rationale for this therapy, as well as a description of the delivery method and clinical application. Specific related nursing interventions are defined in a nursing protocol.23 references.« less
Guarnieri, Michael; Tyler, Betty M; Detolla, Louis; Zhao, Ming; Kobrin, Barry
2014-01-01
Long-acting therapy in laboratory animals offers advantages over the current practice of 2-3 daily drug injections. Yet little is known about the disintegration of biodegradable drug implants in rodents. Compare bioavailability of buprenorphine with the biodegradation of lipid-encapsulated subcutaneous drug pellets. Pharmacokinetic and histopathology studies were conducted in BALB/c female mice implanted with cholesterol-buprenorphine drug pellets. Drug levels are below the level of detection (0.5 ng/mL plasma) within 4-5 days of implant. However, necroscopy revealed that interstitial tissues begin to seal implants within a week. Visual inspection of the implant site revealed no evidence of inflammation or edema associated with the cholesterol-drug residue. Chemical analyses demonstrated that the residues contained 10-13% of the initial opiate dose for at least two weeks post implant. The results demonstrate that biodegradable scaffolds can become sequestered in the subcutaneous space. Drug implants can retain significant and unintended reservoirs of drugs.
Guarnieri, Michael; Tyler, Betty M.; DeTolla, Louis; Zhao, Ming; Kobrin, Barry
2014-01-01
Background: Long-acting therapy in laboratory animals offers advantages over the current practice of 2-3 daily drug injections. Yet little is known about the disintegration of biodegradable drug implants in rodents. Objective: Compare bioavailability of buprenorphine with the biodegradation of lipid-encapsulated subcutaneous drug pellets. Methods: Pharmacokinetic and histopathology studies were conducted in BALB/c female mice implanted with cholesterol-buprenorphine drug pellets. Results: Drug levels are below the level of detection (0.5 ng/mL plasma) within 4-5 days of implant. However, necroscopy revealed that interstitial tissues begin to seal implants within a week. Visual inspection of the implant site revealed no evidence of inflammation or edema associated with the cholesterol-drug residue. Chemical analyses demonstrated that the residues contained 10-13% of the initial opiate dose for at least two weeks post implant. Discussion: The results demonstrate that biodegradable scaffolds can become sequestered in the subcutaneous space. Conclusion: Drug implants can retain significant and unintended reservoirs of drugs. PMID:24459402
Radioactive iodine-125 implantation for cancer of the prostate.
Nag, S
1985-01-01
Localized cancer of the prostate can be treated by radical prostatectomy, external beam irradiation, or radioactive implantation with similar survival results. Radical prostatectomy, however, almost universally results in impotency, although a new, nerve-sparing procedure may preserve potency in B1 patients. External beam irradiation radiates a large volume of tissue with significant rectal and bladder morbidity, 23-47% risk of impotency, and requires prolonged treatment (6-8 weeks). Radioactive implantation may be done suprapubically or transperineally using iodine-125, gold-198, or radon-222 permanent implantation techniques and iridium-192 or radium-226 removable implantation techniques. Interstitial iodine-125 implantation is frequently employed since it is a short procedure and limits the morbidity to a 7% incidence of impotency, 20% urinary complications, and 5% rectal complications. The overall 5-year survival of patients with iodine-125 is 79%, the survival rate decreasing with increasing T or N stage or increasing grade of tumor.
Study of the degradation and recovery of the optical properties of H+-implanted ZnO pigments
NASA Astrophysics Data System (ADS)
Li, Chundong; Lv, Jinpeng; Yao, Shulong; Hu, Jiangang; Liang, Zhiqiang
2013-01-01
We studied the influences of proton implantation and oxygen post-annealing on the optical properties of ZnO pigments using a combination of Raman scattering, positron annihilation and photoluminescence techniques. Raman scattering results indicated that oxygen vacancies and interstitial zinc defects were produced after proton implantation. Positron annihilation spectroscopy and photoluminescence measurements demonstrated that the zinc vacancies do not contribute to the optical absorption, but give rise to the visible band emission. Interestingly, the proton implantation induced optical degradation can be annealed out at 800 °C in an O2 atmosphere. We conclude that the defect centers responsible for the optical absorption are primarily composed of VO+, ionized Zni and ionized Oi.
Depth dependence of defect evolution and TED during annealing
NASA Astrophysics Data System (ADS)
Colombeau, B.; Cowern, N. E. B.; Cristiano, F.; Calvo, P.; Lamrani, Y.; Cherkashin, N.; Lampin, E.; Claverie, A.
2004-02-01
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si + implant conditions have been considered. TEM analysis for the highest energy/dose shows that {1 1 3} defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, {1 1 3} defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical models to simulate defect evolution and TED.
First principles study of hydrogen behaviors in hexagonal tungsten carbide
NASA Astrophysics Data System (ADS)
Kong, Xiang-Shan; You, Yu-Wei; Liu, C. S.; Fang, Q. F.; Chen, Jun-Ling; Luo, G.-N.
2011-11-01
Understanding the behaviors of hydrogen in hexagonal tungsten carbide (WC) is of particular interest for fusion reactor design due to the presence of WC in the divertor of fusion reactors. Here, we have used first principles calculations to study the hydrogen behavior in WC. It is found that the most stable interstitial site for the hydrogen atom is the projection of the octahedral interstitial site on tungsten basal plane, followed by the site near the projection of the octahedral interstitial site on carbon basal plane. The binding energy between two interstitial hydrogen atoms is negative, suggesting that hydrogen itself is not capable of trapping another hydrogen atoms to form hydrogen molecule. The calculated results on the interaction between hydrogen and vacancy indicate that hydrogen atom is preferably trapped by vacancy defects and hydrogen molecule can not be formed in mono-vacancy. In addition, the hydrogen atom bound to carbon is only found in tungsten vacancy. We also study the migrations of hydrogen in WC and find that the interstitial hydrogen atom prefers to diffuse along the c-axis. Our studies provide some explanations for the results of the thermal desorption process of energetic hydrogen ion implanted into WC.
Radiation therapy of primary vaginal carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nori, D.; Hilaris, B.S.; Stanimir, G.
1983-10-01
Primary carcinoma of the vagina is rare, constituting only 1 to 2% of all neoplasms arising in the female genital tract. From 1950-1974, 36 patients with carcinoma of the vagina were treated with radiation at Memorial Sloan-Kettering Cancer Center (MSKCC); 35 (96%) had epidermoid carcinoma and one patient (4%) had adenocarcinoma. These patients were staged according to FIGO. Fourteen patients (39%) were Stage I; six patients (17%) were Stage II; three patients (8%) were Stage III; and 13 patients (36%) were Stage IV. Nine patients (25%) were treated with external radiation and interstitial implant; seven patients (20%) were treated withmore » interstitial implant alone; nine patients (25%) were treated with external radiation alone and 11 patients (30%) with external radiation and intracavitary radiation. The five year NED survival was 71% in Stage I, 66% in Stage II, 33% in Stage III and 0% in Stage IV. This paper discusses radiotherapy management of primary carcinoma of the vagina.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Changdong; Department of Radiation Oncology, Qilu Hospital, Shandong University, Jinan, Shandong 250012; Lu, Fei, E-mail: lufei@sdu.edu.cn
We investigated lattice modification and its physical mechanism in H and He co-implanted, z-cut potassium titanyl phosphate (KTiOPO{sub 4}). The samples were implanted with 110 keV H and 190 keV He, both to a fluence of 4 × 10{sup 16 }cm{sup −2}, at room temperature. Rutherford backscattering/channeling, high-resolution x-ray diffraction, and transmission electron microscopy were used to examine the implantation-induced structural changes and strain. Experimental and simulated x-ray diffraction results show that the strain in the implanted KTiOPO{sub 4} crystal is caused by interstitial atoms. The strain and stress are anisotropic and depend on the crystal's orientation. Transmission electron microscopy studies indicate that ion implantationmore » produces many dislocations in the as-implanted samples. Annealing can induce ion aggregation to form nanobubbles, but plastic deformation and ion out-diffusion prevent the KTiOPO{sub 4} surface from blistering.« less
Fan, Yi; Huang, Ming-Wei; Zheng, Lei; Zhao, Yi-Jiao; Zhang, Jian-Guo
2015-11-24
To evaluate seed stability after permanent implantation in the parotid gland and periparotid region via a three-dimensional reconstruction of CT data. Fifteen patients treated from June 2008 to June 2012 at Peking University School and Hospital of Stomatology for parotid gland tumors with postoperative adjunctive (125)I interstitial brachytherapy were retrospectively reviewed in this study. Serial CT data were obtained during follow-up. Mimics and Geomagic Studio software were used for seed reconstruction and stability analysis, respectively. Seed loss and/or migration outside of the treated area were absent in all patients during follow-up (23-71 months). Total seed cluster volume was maximized on day 1 post-implantation due to edema and decreased significantly by an average of 13.5 % (SD = 9.80 %; 95 % CI, 6.82-17.68 %) during the first two months and an average of 4.5 % (SD = 3.60 %; 95 % CI, 2.29-6.29 %) during the next four months. Volume stabilized over the subsequent six months. (125)I seed number and location were stable with a general volumetric shrinkage tendency in the parotid gland and periparotid region. Three-dimensional seed reconstruction of CT images is feasible for visualization and verification of implanted seeds in parotid brachytherapy.
X-ray analysis of temperature induced defect structures in boron implanted silicon
NASA Astrophysics Data System (ADS)
Sztucki, M.; Metzger, T. H.; Kegel, I.; Tilke, A.; Rouvière, J. L.; Lübbert, D.; Arthur, J.; Patel, J. R.
2002-10-01
We demonstrate the application of surface sensitive diffuse x-ray scattering under the condition of grazing incidence and exit angles to investigate growth and dissolution of near-surface defects after boron implantation in silicon(001) and annealing. Silicon wafers were implanted with a boron dose of 6×1015 ions/cm2 at 32 keV and went through different annealing treatments. From the diffuse intensity close to the (220) surface Bragg peak we reveal the nature and kinetic behavior of the implantation induced defects. Analyzing the q dependence of the diffuse scattering, we are able to distinguish between point defect clusters and extrinsic stacking faults on {111} planes. Characteristic for stacking faults are diffuse x-ray intensity streaks along <111> directions, which allow for the determination of their growth and dissolution kinetics. For the annealing conditions of our crystals, we conclude that the kinetics of growth can be described by an Ostwald ripening model in which smaller faults shrink at the expense of the larger stacking faults. The growth is found to be limited by the self-diffusion of silicon interstitials. After longer rapid thermal annealing the stacking faults disappear almost completely without shrinking, most likely by transformation into perfect loops via a dislocation reaction. This model is confirmed by complementary cross-sectional transmission electron microscopy.
NASA Astrophysics Data System (ADS)
Luebbert, D.; Arthur, J.; Sztucki, M.; Metzger, T. H.; Griffin, P. B.; Patel, J. R.
2002-10-01
Stacking faults in boron-implanted silicon give rise to streaks or rods of scattered x-ray intensity normal to the stacking fault plane. We have used the diffuse scattering rods to follow the growth of faults as a function of time when boron-implanted silicon is annealed in the range of 925 to 1025 degC. From the growth kinetics we obtain an activation energy for interstitial migration in silicon: EI=1.98plus-or-minus0.06 eV. Fault intensity and size versus time results indicate that faults do not shrink and disappear, but rather are annihilated by a dislocation reaction mechanism.
The thermodynamic and kinetic interactions of He interstitial clusters with bubbles in W
Perez, Danny; Sandoval, Luis; Uberuaga, Blas P.; ...
2016-05-26
Due to its enviable properties, tungsten is a leading candidate plasma facing material in nuclear fusion reactors. But, like many other metals, tungsten is known to be affected by the high doses of helium atoms incoming from the plasma. Indeed, the implanted interstitial helium atoms cluster together and, upon reaching a critical cluster size, convert into substitutional nanoscale He bubbles. These bubbles then grow by absorbing further interstitial clusters from the matrix. This process can lead to deleterious changes in microstructure, degradation of mechanical properties, and contamination of the plasma. In order to better understand the growth process, we usemore » traditional and accelerated molecular dynamics simulations to investigate the interactions between interstitial He clusters and pre-existing bubbles. These interactions are characterized in terms of thermodynamics and kinetics. We also show that the proximity of the bubble leads to an enhancement of the trap mutation rate and, consequently, to the nucleation of satellite bubbles in the neighborhood of existing ones. Finally, we uncover a number of mechanisms that can lead to the subsequent annihilation of such satellite nanobubbles.« less
The thermodynamic and kinetic interactions of He interstitial clusters with bubbles in W
NASA Astrophysics Data System (ADS)
Perez, Danny; Sandoval, Luis; Uberuaga, Blas P.; Voter, Arthur F.
2016-05-01
Due to its enviable properties, tungsten is a leading candidate plasma facing material in nuclear fusion reactors. However, like many other metals, tungsten is known to be affected by the high doses of helium atoms incoming from the plasma. Indeed, the implanted interstitial helium atoms cluster together and, upon reaching a critical cluster size, convert into substitutional nanoscale He bubbles. These bubbles then grow by absorbing further interstitial clusters from the matrix. This process can lead to deleterious changes in microstructure, degradation of mechanical properties, and contamination of the plasma. In order to better understand the growth process, we use traditional and accelerated molecular dynamics simulations to investigate the interactions between interstitial He clusters and pre-existing bubbles. These interactions are characterized in terms of thermodynamics and kinetics. We show that the proximity of the bubble leads to an enhancement of the trap mutation rate and, consequently, to the nucleation of satellite bubbles in the neighborhood of existing ones. We also uncover a number of mechanisms that can lead to the subsequent annihilation of such satellite nanobubbles.
A Fully Implantable, NFC Enabled, Continuous Interstitial Glucose Monitor
Anabtawi, Nijad; Freeman, Sabrina; Ferzli, Rony
2017-01-01
This work presents an integrated system-on-chip (SoC) that forms the core of a long-term, fully implantable, battery assisted, passive continuous glucose monitor. It integrates an amperometric glucose sensor interface, a near field communication (NFC) wireless front-end and a fully digital switched mode power management unit for supply regulation and on board battery charging. It uses 13.56 MHz (ISM) band to harvest energy and backscatter data to an NFC reader. System was implemented in 14nm CMOS technology and validated with post layout simulations. PMID:28702512
A Fully Implantable, NFC Enabled, Continuous Interstitial Glucose Monitor.
Anabtawi, Nijad; Freeman, Sabrina; Ferzli, Rony
2016-02-01
This work presents an integrated system-on-chip (SoC) that forms the core of a long-term, fully implantable, battery assisted, passive continuous glucose monitor. It integrates an amperometric glucose sensor interface, a near field communication (NFC) wireless front-end and a fully digital switched mode power management unit for supply regulation and on board battery charging. It uses 13.56 MHz (ISM) band to harvest energy and backscatter data to an NFC reader. System was implemented in 14nm CMOS technology and validated with post layout simulations.
Experimental confirmation of the predicted shallow donor hydrogen state in zinc oxide.
Cox, S F; Davis, E A; Cottrell, S P; King, P J; Lord, J S; Gil, J M; Alberto, H V; Vilão, R C; Piroto Duarte, J; Ayres de Campos, N; Weidinger, A; Lichti, R L; Irvine, S J
2001-03-19
We confirm the recent prediction that interstitial protium may act as a shallow donor in zinc oxide, by direct spectroscopic observation of its muonium counterpart. On implantation into ZnO, positive muons--chemically analogous to protons in this context--form paramagnetic centers below about 40 K. The muon-electron contact hyperfine interaction, as well as the temperature and activation energy for ionization, imply a shallow level. Similar results for the cadmium chalcogenides suggest that such shallow donor states are generic to the II-VI compounds. The donor level depths should serve as a guide for the electrical activity of interstitial hydrogen.
BCA-kMC Hybrid Simulation for Hydrogen and Helium Implantation in Material under Plasma Irradiation
NASA Astrophysics Data System (ADS)
Kato, Shuichi; Ito, Atsushi; Sasao, Mamiko; Nakamura, Hiroaki; Wada, Motoi
2015-09-01
Ion implantation by plasma irradiation into materials achieves the very high concentration of impurity. The high concentration of impurity causes the deformation and the destruction of the material. This is the peculiar phenomena in the plasma-material interaction (PMI). The injection process of plasma particles are generally simulated by using the binary collision approximation (BCA) and the molecular dynamics (MD), while the diffusion of implanted atoms have been traditionally solved by the diffusion equation, in which the implanted atoms is replaced by the continuous concentration field. However, the diffusion equation has insufficient accuracy in the case of low concentration, and in the case of local high concentration such as the hydrogen blistering and the helium bubble. The above problem is overcome by kinetic Monte Carlo (kMC) which represents the diffusion of the implanted atoms as jumps on interstitial sites in a material. In this paper, we propose the new approach ``BCA-kMC hybrid simulation'' for the hydrogen and helium implantation under the plasma irradiation.
Carcinoma of the floor of the mouth: a 20-year experience.
Aygun, C; Salazar, O M; Sewchand, W; Amornmarn, R; Prempree, T
1984-05-01
From 1955 to 1975, 116 patients with squamous cell carcinoma of the floor of the mouth were primarily treated by irradiation in the Department of Radiation Oncology, University of Maryland at Baltimore. Of these, 93 evaluable patients yielded loco-regional control rates of 83, 85, 42 and 21% for Stages I-IV, respectively. A palisading technique of radium needle implants was used, either alone or combined with external beam therapy, for early tumors (Stages I-II). Similar control rates were achieved by these two techniques: 13/14 for interstitial irradiation alone and 16/24 for combined interstitial and external irradiation. In selected early cases (Stages I-II), errors in staging were minimized by the systematic use of a needle biopsy of the submaxillary triangle for suspicious submaxillary swellings. Patients with early lesions and truly negative nodes (N0) only received irradiation to the primary tumor bed. No subsequent nodal neck failures have occurred in 13 of such patients. The overall complication rate for the entire series was 17% with only 8 patients requiring surgery. No differences in complication rates were found among the treatment modalities employed. The distribution of lymph nodal involvement by anatomical level, correlation of histological differentiation or tumor aggressiveness at presentation, the dosimetric analysis of the palisading interstitial technique, the spread and failure patterns and other observations are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steen-Banasik, Elzbieta M. van der, E-mail: E.vanderSteen-Banasik@radiotherapiegroep.nl; Smits, Geert A.H.J.; Oosterveld, Bernard J.
Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach withmore » robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.« less
Lattice sites of ion-implanted Mn, Fe and Ni in 6H-SiC
NASA Astrophysics Data System (ADS)
Costa, A. R. G.; Wahl, U.; Correia, J. G.; David-Bosne, E.; Amorim, L. M.; Augustyns, V.; Silva, D. J.; da Silva, M. R.; Pereira, L. M. C.
2018-01-01
Using radioactive isotopes produced at the CERN-ISOLDE facility, the lattice location of the implanted transition metal (TM) ions 56Mn, 59Fe and 65Ni in n-type single-crystalline hexagonal 6H-SiC was studied by means of the emission channeling technique. TM probes on carbon coordinated tetrahedral interstitial sites (T C) and on substitutional silicon sites (S Si,h+k ) were identified. We tested for but found no indication that the TM distribution on S Si sites deviates from the statistical mixture of 1/3 hexagonal and 2/3 cubic sites present in the 6H crystal. The TM atoms partially disappear from T C positions during annealing at temperatures between 500 °C and 700 °C which is accompanied by an increase on S Si and random sites. From the temperature associated with these site changes, interstitial migration energies of 1.7-2.7 eV for Mn and Ni, and 2.3-3.2 eV for Fe were estimated. TM lattice locations are compared to previous results obtained in 3C-SiC using the same technique.
NMR Observation of Mobile Protons in Proton-Implanted ZnO Nanorods
Park, Jun Kue; Kwon, Hyeok-Jung; Lee, Cheol Eui
2016-01-01
The diffusion properties of H+ in ZnO nanorods are investigated before and after 20 MeV proton beam irradiation by using 1H nuclear magnetic resonance (NMR) spectroscopy. Herein, we unambiguously observe that the implanted protons occupy thermally unstable site of ZnO, giving rise to a narrow NMR line at 4.1 ppm. The activation barrier of the implanted protons was found to be 0.46 eV by means of the rotating-frame spin-lattice relaxation measurements, apparently being interstitial hydrogens. High-energy beam irradiation also leads to correlated jump diffusion of the surface hydroxyl group of multiple lines at ~1 ppm, implying the presence of structural disorder at the ZnO surface. PMID:26988733
Targeted Prostate Thermal Therapy with Catheter-Based Ultrasound Devices and MR Thermal Monitoring
NASA Astrophysics Data System (ADS)
Diederich, Chris; Ross, Anthony; Kinsey, Adam; Nau, Will H.; Rieke, Viola; Butts Pauly, Kim; Sommer, Graham
2006-05-01
Catheter-based ultrasound devices have significant advantages for thermal therapy procedures, including potential for precise spatial and dynamic control of heating patterns to conform to targeted volumes. Interstitial and transurethral ultrasound applicators, with associated treatment strategies, were developed for thermal ablation of prostate combined with MR thermal monitoring. Four types of multielement transurethral applicators were devised, each with different levels of selectivity and intended therapeutic goals: sectored tubular transducer devices with fixed directional heating patterns; planar and lightly focused curvilinear devices with narrow heating patterns; and multi-sectored tubular devices capable of dynamic angular control without applicator movement. These devices are integrated with a 4 mm delivery catheter, incorporate an inflatable cooling balloon (10 mm OD) for positioning within the prostate and capable of rotation via an MR-compatible motor. Similarly, interstitial devices (2.4 mm OD) have been developed for percutaneous implantation with fixed directional heating patterns (e.g., 180 deg.). In vivo experiments in canine prostate (n=15) under MR temperature imaging were used to evaluate the heating technology and develop treatment strategies. MR thermal imaging in a 0.5 T interventional MRI was used to monitor temperature contours and thermal dose in multiple slices through the target volume. Sectored transurethral devices produce directional coagulation zones, extending 15-20 mm radial distance to the outer prostate capsule. The curvilinear applicator produces distinct 2-3 mm wide lesions, and with sequential rotation and modulated dwell time can precisely conform thermal ablation to selected areas or the entire prostate gland. Multi-sectored transurethral applicators can dynamically control the angular heating profile and target large regions of the gland in short treatment times without applicator manipulation. Interstitial implants with directional devices can be used to effectively ablate the posterior peripheral zone of the gland while protecting the rectum. An implant with multi-sectored interstitial devices can effectively control the angular heating pattern without applicator rotation. The MR derived 52 °C and lethal thermal dose contours (t43=240 min) allowed for real-time control of the applicators and effectively defined the extent of thermal damage. Catheter-based ultrasound devices, combined with MR thermal monitoring, can produce relatively fast and precise thermal ablation of prostate, with potential for treatment of cancer or BPH.
Origins of low resistivity and Ge donor level in Ge ion-implanted ZnO bulk single crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamioka, K.; Oga, T.; Izawa, Y.
2013-12-04
The energy level of Ge in Ge-ion implanted ZnO single crystals is studied by Hall-effect and photoluminescence (PL) methods. The variations in resistivity from ∼10{sup 3} Ωcm for un-implanted samples to ∼10{sup −2} Ωcm for as-implanted ones are observed. The resistivity is further decreased to ∼10{sup −3} Ωcm by annealing. The origins of the low resistivity are attributed to both the zinc interstitial (Zn{sub i}) related defects and the electrical activated Ge donor. An activation energy of Ge donors estimated from the temperature dependence of carrier concentration is 102 meV. In PL studies, the new peak at 372 nm (3.33more » eV) related to the Ge donor is observed in 1000 °C annealed samples.« less
Lattice disorder produced in GaN by He-ion implantation
NASA Astrophysics Data System (ADS)
Han, Yi; Peng, Jinxin; Li, Bingsheng; Wang, Zhiguang; Wei, Kongfang; Shen, Tielong; Sun, Jianrong; Zhang, Limin; Yao, Cunfeng; Gao, Ning; Gao, Xing; Pang, Lilong; Zhu, Yabin; Chang, Hailong; Cui, Minghuan; Luo, Peng; Sheng, Yanbin; Zhang, Hongpeng; Zhang, Li; Fang, Xuesong; Zhao, Sixiang; Jin, Jin; Huang, Yuxuan; Liu, Chao; Tai, Pengfei; Wang, Dong; He, Wenhao
2017-09-01
The lattice disorders induced by He-ion implantation in GaN epitaxial films to fluences of 2 × 1016, 5 × 1016 and 1 × 1017 cm-2 at room temperature (RT) have been investigated by a combination of Raman spectroscopy, high-resolution X-ray diffraction (HRXRD), nano-indentation, and transmission electron microscopy (TEM). The experimental results present that Raman intensity decreases with increasing fluence. Raman frequency "red shift" occurs after He-ion implantation. Strain increases with increasing fluence. The hardness of the highly damaged layer increases monotonically with increasing fluence. Microstructural results demonstrate that the width of the damage band and the number density of observed dislocation loops increases with increasing fluence. High-resolution TEM images exhibit that He-ion implantation lead to the formation of planar defects and most of the lattice defects are of interstitial-type basal loops. The relationships of Raman intensity, lattice strain, swelling and hardness with He-implantation-induced lattice disorders are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez, Danny, E-mail: danny-perez@lanl.gov; Sandoval, Luis; Voter, Arthur F.
Due to its enviable properties, tungsten is a leading candidate plasma facing material in nuclear fusion reactors. However, like many other metals, tungsten is known to be affected by the high doses of helium atoms incoming from the plasma. Indeed, the implanted interstitial helium atoms cluster together and, upon reaching a critical cluster size, convert into substitutional nanoscale He bubbles. These bubbles then grow by absorbing further interstitial clusters from the matrix. This process can lead to deleterious changes in microstructure, degradation of mechanical properties, and contamination of the plasma. In order to better understand the growth process, we usemore » traditional and accelerated molecular dynamics simulations to investigate the interactions between interstitial He clusters and pre-existing bubbles. These interactions are characterized in terms of thermodynamics and kinetics. We show that the proximity of the bubble leads to an enhancement of the trap mutation rate and, consequently, to the nucleation of satellite bubbles in the neighborhood of existing ones. We also uncover a number of mechanisms that can lead to the subsequent annihilation of such satellite nanobubbles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez, Danny; Sandoval, Luis; Uberuaga, Blas P.
Due to its enviable properties, tungsten is a leading candidate plasma facing material in nuclear fusion reactors. But, like many other metals, tungsten is known to be affected by the high doses of helium atoms incoming from the plasma. Indeed, the implanted interstitial helium atoms cluster together and, upon reaching a critical cluster size, convert into substitutional nanoscale He bubbles. These bubbles then grow by absorbing further interstitial clusters from the matrix. This process can lead to deleterious changes in microstructure, degradation of mechanical properties, and contamination of the plasma. In order to better understand the growth process, we usemore » traditional and accelerated molecular dynamics simulations to investigate the interactions between interstitial He clusters and pre-existing bubbles. These interactions are characterized in terms of thermodynamics and kinetics. We also show that the proximity of the bubble leads to an enhancement of the trap mutation rate and, consequently, to the nucleation of satellite bubbles in the neighborhood of existing ones. Finally, we uncover a number of mechanisms that can lead to the subsequent annihilation of such satellite nanobubbles.« less
Huang, Ming-Wei; Liu, Shu-Ming; Zheng, Lei; Shi, Yan; Zhang, Jie; Li, Yan-Sheng; Yu, Guang-Yan; Zhang, Jian-Guo
2012-11-01
To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Before (125)I implants, patients received CT scans based on 0.75mm thickness. And the brachytherapy treatment planning system (BTPS) software was used to make the implantation plan based on the CT images. Mimics software and Geomagic software were used to read the data containing CT images and implantation plan, and to design the individual template. Then the individual template containing the information of needle pathway and face features simultaneously was made through rapid prototyping (RP) technique. All patients received (125)I seeds interstitial implantation under the guide of the individual template and CT. The individual templates were positioned easily and accurately, and were stable. After implants, treatment quality evaluation was made by CT and TPS. The seeds and dosages distribution (D(90),V(100),V(150)) were well meet the treatment requirement. Clinical practice confirms that this approach can facilitate easier and more accurate implantation.
Origin of magnetic properties in carbon implanted ZnO nanowires.
Wang, Y F; Shao, Y C; Hsieh, S H; Chang, Y K; Yeh, P H; Hsueh, H C; Chiou, J W; Wang, H T; Ray, S C; Tsai, H M; Pao, C W; Chen, C H; Lin, H J; Lee, J F; Wu, C T; Wu, J J; Chang, Y M; Asokan, K; Chae, K H; Ohigashi, T; Takagi, Y; Yokoyama, T; Kosugi, N; Pong, W F
2018-05-17
Various synchrotron radiation-based spectroscopic and microscopic techniques are used to elucidate the room-temperature ferromagnetism of carbon-doped ZnO-nanowires (ZnO-C:NW) via a mild C + ion implantation method. The photoluminescence and magnetic hysteresis loops reveal that the implantation of C reduces the number of intrinsic surface defects and increases the saturated magnetization of ZnO-NW. The interstitial implanted C ions constitute the majority of defects in ZnO-C:NW as confirmed by the X-ray absorption spectroscopic studies. The X-ray magnetic circular dichroism spectra of O and C K-edge respectively indicate there is a reduction in the number of unpaired/dangling O 2p bonds in the surface region of ZnO-C:NW and the C 2p-derived states of the implanted C ions strongly affect the net spin polarization in the surface and bulk regions of ZnO-C:NW. Furthermore, these findings corroborate well with the first-principles calculations of C-implanted ZnO in surface and bulk regions, which highlight the stability of implanted C for the suppression and enhancement of the ferromagnetism of the ZnO-C:NW in the surface region and bulk phase, respectively.
Fu, K K; Ray, J W; Chan, E K; Phillips, T L
1976-01-01
In 204 patients with squamous cell carcinoma of the oral tongue treated with radiation therapy, the most significant prognostic factors appeared to be the presence of neck lymph node metastasis on presentation and the status of the disease three months after treatment. The most common site of failure was the primary lesion, either alone or with neck disease. External irradiation alone was seldom successful. Use of peroral cone irradiation or interstitial implants, either alone or in combination with external irradiation, achieved good local control in early lesions. When the primary tumor was uncontrolled by radiation therapy, salvage with surgery was rare. When failure occurred in the neck alone, radical neck dissection was successful in the majority of cases.
NASA Astrophysics Data System (ADS)
Lampin, E.; Cristiano, F.; Lamrani, Y.; Colombeau, B.
2004-02-01
We present simulations of B TED based on a complete calculation of the extended defect growth/shrinkage during annealing. The Si self-interstitial supersaturation calculated at the extended defect depth is coupled to the set of equations for the B kick-out diffusion through a generation/recombination term in the diffusion equation of the Si self-interstitials. The simulations are compared to the measurements performed on a Si wafer containing several B marker layers, where the amount of TED varies from one peak to the other. The good agreement obtained on this experiment is very promising for the application of these calculations to the case of ultra-shallow B + implants.
NASA Astrophysics Data System (ADS)
Zhang, X.; Connelly, D.; Takeuchi, H.; Hytha, M.; Mears, R. J.; Rubin, L. M.; Liu, T.-J. K.
2018-03-01
The effects of oxygen-inserted (OI) layers on the diffusion of boron (B), phosphorus (P), and arsenic (As) in silicon (Si) are investigated, for ultra-shallow junction formation by high-dose ion implantation followed by rapid thermal annealing. The projected range (Rp) of the implanted dopants is shallower than the depth of the OI layers. Secondary ion mass spectrometry is used to compare the dopant profiles in silicon samples that have OI layers against the dopant profiles in control samples that do not have OI layers. Diffusion is found to be substantially retarded by the OI layers for B and P, and less for As, providing shallower junction depth. The experimental results suggest that the OI layers serve to block the diffusion of Si self-interstitials and thereby effectively reduce interstitial-aided diffusion beyond the depth of the OI layers. The OI layers also help to retain more dopants within the Si, which technology computer-aided design simulations indicate to be beneficial for achieving shallower junctions with lower sheet resistance to enable further miniaturization of planar metal-oxide-semiconductor field-effect transistors for improved integrated-circuit performance and cost per function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sobolev, N. A., E-mail: nick@sobolev.ioffe.rssi.ru; Shtel’makh, K. F.; Kalyadin, A. E.
2015-12-15
Low-temperature photoluminescence in n-Cz-Si after the implantation of erbium ions at an elevated temperature and subsequent implantation of oxygen ions at room temperature is studied. So-called X and W centers formed from self-interstitial silicon atoms, H and P centers containing oxygen atoms, and Er centers containing Er{sup 3+} ions are observed in the photoluminescence spectra. The energies of enhancing and quenching of photoluminescence for these centers are determined. These energies are determined for the first time for X and H centers. In the case of P and Er centers, the values of the energies practically coincide with previously published data.more » For W centers, the energies of the enhancing and quenching of photoluminescence depend on the conditions of the formation of these centers.« less
Kohan, A D; Armenakas, N A; Fracchia, J A
2000-02-01
We compare the comprehensive 1-year charges in a consecutive group of patients undergoing radical prostatectomy and transperineal interstitial brachytherapy for clinically localized prostate cancer at a single urban institution. A total of 60 consecutive men with clinically localized prostate cancer (T1-T2, N0, M0) were treated during a 15-month period with radical prostatectomy or interstitial brachytherapy. Hospital and outpatient records were analyzed for each patient in regard to preoperative, operative and postoperative charges. Parameters included number of encounters, diagnostic and therapeutic interventions, hospitalization and operative charges, and followup visits, diagnostic tests and interventions for 1 year. All charge calculations were based arbitrarily on the 1996 Medicare fee schedule, factoring in the mandated global charge reimbursement period of 90 days for both procedures. Of the patients 38 underwent radical prostatectomy (prostatectomy group) and 22 underwent interstitial brachytherapy (brachytherapy group). The brachytherapy group was older with higher pretreatment serum prostate specific antigen and clinical stage disease, and more frequently received neoadjuvant hormonal therapy compared to the prostatectomy group. The 2 groups were similar in Gleason score and, when applicable, duration of neoadjuvant hormonal therapy. Preoperative charges were 15.3% lower for prostatectomy than for brachytherapy (not statistically significant). Conversely, operative charges for prostatectomy were 13.5% higher (p = 0.04). The major difference among preoperative, operative and postoperative charges was for those incurred postoperatively by the brachytherapy group, which were 56.0% higher than those for the prostatectomy group ($2,285.20 versus $1,007.20, p = 0.0004). Transperineal interstitial seed implantation is perceived by many as more cost-effective than radical prostatectomy for patients with clinically localized prostate cancer. We demonstrated that when such patients were followed for 1 year, the comprehensive charges for radical prostatectomy and interstitial brachytherapy were equivalent.
CT guided interstitial therapy of pancreatic carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haaga, J.R.; Owens, D.B.; Kellermeyer, R.W.
1987-11-01
We describe the use of percutaneous CT guidance for localization and placement of /sup 192/Ir sources into a patient with pancreatic carcinoma. We have shown the feasibility of this procedure and the lack of complications which are probably due to minimal damage to tissue involved. Computed tomography is ideally suited for percutaneous implantation because it provides the most accurate method for needle placement within the abdomen.
Thermoseeds for interstitial magnetic hyperthermia: from bioceramics to nanoparticles
NASA Astrophysics Data System (ADS)
Baeza, A.; Arcos, D.; Vallet-Regí, M.
2013-12-01
The development of magnetic materials for interstitial hyperthermia treatment of cancer is an ever evolving research field which provides new alternatives to antitumoral therapies. The development of biocompatible magnetic materials has resulted in new biomaterials with multifunctional properties, which are able to adapt to the complex scenario of tumoral processes. Once implanted or injected in the body, magnetic materials can behave as thermoseeds under the effect of AC magnetic fields. Magnetic bioceramics aimed to treat bone tumors and magnetic nanoparticles are among the most studied thermoseeds, and supply different solutions for the different scenarios in cancerous processes. This paper reviews some of the biomaterials used for bone cancer treatment and skeletal reinforcing, as well as the more complex topic of magnetic nanoparticles for intracellular targeting and hyperthermia.
Thermoseeds for interstitial magnetic hyperthermia: from bioceramics to nanoparticles.
Baeza, A; Arcos, D; Vallet-Regí, M
2013-12-04
The development of magnetic materials for interstitial hyperthermia treatment of cancer is an ever evolving research field which provides new alternatives to antitumoral therapies. The development of biocompatible magnetic materials has resulted in new biomaterials with multifunctional properties, which are able to adapt to the complex scenario of tumoral processes. Once implanted or injected in the body, magnetic materials can behave as thermoseeds under the effect of AC magnetic fields. Magnetic bioceramics aimed to treat bone tumors and magnetic nanoparticles are among the most studied thermoseeds, and supply different solutions for the different scenarios in cancerous processes. This paper reviews some of the biomaterials used for bone cancer treatment and skeletal reinforcing, as well as the more complex topic of magnetic nanoparticles for intracellular targeting and hyperthermia.
Gyenge, Christina C; Tenstad, Olav; Wiig, Helge
2003-01-01
In order to estimate the magnitude of electrostatic exclusion provided by the fixed negative charges of the skin and muscle interstitia of rat in vivo we measured the distribution volumes of two differently charged albumin probes within these tissues. An implanted osmotic pump was used to reach and maintain a steady-state extracellular concentration of a mixture containing two iodine-labelled probes: a charged-modified human serum albumin, cHSA (i.e. a positive probe, isoelectirc point (pI) = 7.6) and a native human serum albumin, HSA (i.e. a normally charged, negative probe, pI = 5.0). Steady-state tissue concentrations were achieved after intravenous infusion of probes for 5–7 days. At the end of this period the animals were nephrectomized and a bolus of 51Cr-EDTA was administered for estimating the extracellular volume. Plasma volumes were measured as 5-min distribution volume of 125I-HSA in separate experiments. The steady-state interstitial fluid concentrations of all probes were determined using nylon wicks implanted postmortem. Calculations of labelled probes were made for interstitial fluid volumes (Vi), extravascular albumin distribution volumes (Vav,a) and relative interstitial excluded volume fractions (Vex,a/Vi). We found that the positive probe is excluded from a significantly smaller fraction of the interstitium. Specifically, the average relative albumin exclusion fractions obtained were: 16% and 26% in skeletal muscle and 30% and 40% in skin, for cHSA and HSA, respectively. On average, the fixed negative charges of the interstitium are responsible for about 40% of the total albumin exclusion in skeletal muscle and 25% in the whole skin tissue and thus, contribute significantly to volume exclusion in these tissues. PMID:12937287
Gyenge, Christina C; Tenstad, Olav; Wiig, Helge
2003-11-01
In order to estimate the magnitude of electrostatic exclusion provided by the fixed negative charges of the skin and muscle interstitia of rat in vivo we measured the distribution volumes of two differently charged albumin probes within these tissues. An implanted osmotic pump was used to reach and maintain a steady-state extracellular concentration of a mixture containing two iodine-labelled probes: a charged-modified human serum albumin, cHSA (i.e. a positive probe, isoelectirc point (pI) = 7.6) and a native human serum albumin, HSA (i.e. a normally charged, negative probe, pI = 5.0). Steady-state tissue concentrations were achieved after intravenous infusion of probes for 5-7 days. At the end of this period the animals were nephrectomized and a bolus of 51Cr-EDTA was administered for estimating the extracellular volume. Plasma volumes were measured as 5-min distribution volume of 125I-HSA in separate experiments. The steady-state interstitial fluid concentrations of all probes were determined using nylon wicks implanted postmortem. Calculations of labelled probes were made for interstitial fluid volumes (Vi), extravascular albumin distribution volumes (Vav,a) and relative interstitial excluded volume fractions (Vex,a/Vi). We found that the positive probe is excluded from a significantly smaller fraction of the interstitium. Specifically, the average relative albumin exclusion fractions obtained were: 16% and 26% in skeletal muscle and 30% and 40% in skin, for cHSA and HSA, respectively. On average, the fixed negative charges of the interstitium are responsible for about 40% of the total albumin exclusion in skeletal muscle and 25% in the whole skin tissue and thus, contribute significantly to volume exclusion in these tissues.
NASA Astrophysics Data System (ADS)
Carroll, M. S.; Chang, C.-L.; Sturm, J. C.; Büyüklimanli, T.
1998-12-01
In this letter, we show the ability, through introduction of a thin Si1-x-yGexCy layer, to eliminate the enhancement of enhanced boron diffusion in silicon due to an oxidizing surface or ion implant damage. This reduction of diffusion is accomplished through a low-temperature-grown thin epitaxial Si1-x-yGexCy layer which completely filters out excess interstitials introduced by oxidation or ion implant damage. We also quantify the oxidation-enhanced diffusion (OED) and transient-enhanced diffusion (TED) dependence on substitutional carbon level, and further report both the observation of carbon TED and OED, and its dependence on carbon levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krempien, Robert; Hoppe, Harald; Kahrs, Lueder
Purpose: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. Methods and Materials: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. Results: In a first clinical study,more » we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). Conclusions: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.« less
Fe implantation effect in the 6H-SiC semiconductor investigated by Mössbauer spectrometry
NASA Astrophysics Data System (ADS)
Diallo, M. L.; Diallo, L.; Fnidiki, A.; Lechevallier, L.; Cuvilly, F.; Blum, I.; Viret, M.; Marteau, M.; Eyidi, D.; Juraszek, J.; Declémy, A.
2017-08-01
P-doped 6H-SiC substrates were implanted with 57Fe ions at 380 °C or 550 °C to produce a diluted magnetic semiconductor with an Fe homogeneous concentration of about 100 nm thickness. The magnetic properties were studied with 57Fe Conversion Electron Mössbauer Spectrometry at room temperature (RT). Results obtained by this technique on annealed samples prove that ferromagnetism in 57Fe-implanted SiC for Fe concentrations close to 2% and 4% is mostly due to Fe atoms diluted in the matrix. In contrast, for Fe concentrations close to 6%, it also comes from Fe in magnetic phase nano-clusters. This study allows quantifying the Fe amount in the interstitial and substitutional sites and the nanoparticles and shows that the majority of the diluted Fe atoms are substituted on Si sites inducing ferromagnetism up to RT.
New transurethral system for interstitial radiation of prostate cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumgartner, G.; Callahan, D.; McKiel, C.F. Jr.
Direct endoscopic implantation of radioactive materials for carcinoma of the prostate without an open operation was accomplished by the use of modified existing transurethral instrumentation and techniques. The closed approach seems applicable particularly to the geriatric population, which is afflicted more commonly but is frequently not treated because of concurrent diseases or because the patient had transurethral resection of the prostate as a diagnostic procedure. Eleven patients were implanted using the transurethral route. Implantations were accomplished successfully with extremely low morbidity. Along with more conventional dosimetry studies, computer tomography was used to assess the placement of seeds. The direct visualizationmore » of the method suggests a potential for greater precision of seed placement as illustrated by computer tomography. In addition, this new instrumentation and method offers a low-risk procedure for carcinoma of the prostate that can be performed on an outpatient basis for selected patients.« less
NASA Astrophysics Data System (ADS)
Nau, William H.; Diederich, Chris J.; Shu, Richard
2005-06-01
Application of heat in the spine using resistive wire heating devices is currently being used clinically for minimally invasive treatment of discogenic low back pain. In this study, interstitial ultrasound was evaluated for the potential to heat intradiscal tissue more precisely by directing energy towards the posterior annular wall while avoiding vertebral bodies. Two single-element directional applicator design configurations were tested: a 1.5 mm OD direct-coupled (DC) applicator which can be implanted directly within the disc, and a catheter-cooled (CC) applicator which is inserted in a 2.4 mm OD catheter with integrated water cooling and implanted within the disc. The transducers were sectored to produce 90° spatial heating patterns for directional control. Both applicator configurations were evaluated in four human cadaver lumbar disc motion segments. Two heating protocols were employed in this study in which the temperature measured 5 mm away from the applicator was controlled to either T = 52 °C, or T > 70 °C for the treatment period. These temperatures (thermal doses) are representative of those required for thermal necrosis of in-growing nociceptor nerve fibres and disc cellularity alone, or with coagulation and restructuring of annular collagen in the high-temperature case. Steady-state temperature maps, and thermal doses (t43) were used to assess the thermal treatments. Results from these studies demonstrated the capability of controlling temperature distributions within selected regions of the disc and annular wall using interstitial ultrasound, with minimal vertebral end-plate heating. While directional heating was demonstrated with both applicator designs, the CC configuration had greater directional heating capabilities and offered better temperature control than the DC configuration, particularly during the high-temperature protocol. Further, ultrasound energy was capable of penetrating within the highly attenuating disc tissue to produce more extensive radial thermal penetration, lower maximum intradiscal temperature, and shorter treatment times than can be achieved with current clinical intradiscal heating technology. Thus, interstitial ultrasound offers potential as a more precise and faster heating modality for the clinical management of low back pain.
Connolly, Jeanne M.; Alferiev, Ivan; Clark-Gruel, Jocelyn N.; Eidelman, Naomi; Sacks, Michael; Palmatory, Elizabeth; Kronsteiner, Allyson; DeFelice, Suzanne; Xu, Jie; Ohri, Rachit; Narula, Navneet; Vyavahare, Narendra; Levy, Robert J.
2005-01-01
We investigated a novel polyepoxide crosslinker that was hypothesized to confer both material stabilization and calcification resistance when used to prepare bioprosthetic heart valves. Triglycidylamine (TGA) was synthesized via reacting epichlorhydrin and NH3. TGA was used to crosslink porcine aortic cusps, bovine pericardium, and type I collagen. Control materials were crosslinked with glutaraldehyde (Glut). TGA-pretreated materials had shrink temperatures comparable to Glut fixation. However, TGA crosslinking conferred significantly greater collagenase resistance than Glut pretreatment, and significantly improved biomechanical compliance. Sheep aortic valve interstitial cells grown on TGA-pretreated collagen did not calcify, whereas sheep aortic valve interstitial cells grown on control substrates calcified extensively. Rat subdermal implants (porcine aortic cusps/bovine pericardium) pretreated with TGA demonstrated significantly less calcification than Glut pretreated implants. Investigations of extracellular matrix proteins associated with calcification, matrix metalloproteinases (MMPs) 2 and 9, tenascin-C, and osteopontin, revealed that MMP-9 and tenascin-C demonstrated reduced expression both in vitro and in vivo with TGA crosslinking compared to controls, whereas osteopontin and MMP-2 expression were not affected. TGA pretreatment of heterograft biomaterials results in improved stability compared to Glut, confers biomechanical properties superior to Glut crosslinking, and demonstrates significant calcification resistance. PMID:15631995
Safety of Laser Interstitial Thermal Therapy in Patients With Pacemakers.
Grewal, Sanjeet S; Gorny, Krzysztof R; Favazza, Christopher P; Watson, Robert E; Kaufmann, Timothy J; Van Gompel, Jamie J
2018-02-10
Laser interstitial thermal therapy (LiTT) has increasingly been used as a treatment option for medically refractory epilepsy, tumors, and radiation necrosis. The use of LiTT requires intraoperative magnetic resonance (MR) thermography. This can become an issue in patients with other implanted therapeutic devices such as pacemakers and vagal nerve stimulators due to concerns regarding increases in the specific absorption rate (SAR). This is a technical case report demonstrating a successfully and safely performed LiTT in a 1.5-T magnetic resonance imaging (MRI) in a patient with a pacemaker for mesial temporal sclerosis. An 83-yr-old gentleman who had an implanted cardiac pacemaker presented with medically intractable epilepsy and was confirmed to have mesial temporal sclerosis on imaging. Video electroencephalography demonstrated concordant ipsilateral seizures and semiology. He underwent LiTT for ablation of the mesial temporal lobe. This was performed with the below described protocol with a cardiology nurse monitoring the patient's cardiac condition and a physicist monitoring SAR, and MR imaging quality without any adverse events. This study reports on a protocol of cardiac and MR SAR to safely perform MR-guided LiTT in the setting of traditional pacemakers in patients who are not pacemaker dependent. Copyright © 2018 by the Congress of Neurological Surgeons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, S; Kim, R; Benhabib, S
Purpose: HDR brachytherapy using interstitial needle template for cervical cancer is commonly delivered in 4-5 fractions. Routine verification of needle positions before each fraction is often based on radiographic imaging of implanted fiducial markers. The current study evaluated interfractional displacement of implanted fiducial markers using CT images. Methods: 9 sequential patients with cervical interstitial needle implants were evaluated. The superior and inferior borders of the target volumes were defined by fiducial markers in planning CT. The implant position was verified with kV orthogonal images before each fraction. A second CT was acquired prior 3rd fraction (one or 2 days postmore » planning CT). Distances from inferior and superior fiducial markers to pubic symphysis plane (perpendicular to vaginal obtulator)were measured. Distance from needle tip of a reference needle (next to the inferior marker) to the pubic symphysis plane was also determined. The difference in fiducial marker distance or needle tip distance between planning CT and CT prior 3rd fraction were measured to assess markers migration and needle displacement. Results: The mean inferior marker displacement was 4.5 mm and ranged 0.9 to 11.3 mm. The mean superior marker displacement was 2.7 mm and ranged 0 to 10.4 mm. There was a good association between inferior and superior marker displacement (r=0.95). Mean averaged inferior and superior marker displacement was 3.3 mm and ranged from 0.1 to 10.9 mm, with a standard deviation of 3.2 mm. The mean needle displacement was 5.6 mm and ranged 0.2 to 15.6 mm. Needle displacements were reduced (p<0.05) after adjusting according to needle-to-fiducials distance. Conclusion: There were small fiducial marker displacements between HDR fractions. Our study suggests a target margin of 9.7 mm to cover interfractional marker displacements (in 95% cases) for pretreatment verification based on radiographic imaging.« less
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.
2011-09-01
Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within temporary HDR brachytherapy implants during radiation therapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length×180 deg and 3-4 cm×360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers x dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and four prostate implants. 100% of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target volume (HTV) and clinical target volume (CTV) are reported. Catheter-based ultrasound hyperthermia with HDR appears feasible with therapeutic temperature coverage of the target volume within the prostate or cervix while sparing surrounding more sensitive regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bandriyana,, E-mail: bandri@batan.go.id; Ismoyo, Agus Hadi; Dimyati, A.
Surface treatment by implantation with nitrogen-ion was performed on the commercial feritic high strength steel AISI 410 which is termed for high temperature applications. The aim of this research was focused on the surface modification to improve its high temperature oxidation property in the early stages. Ion implantation was carried out at acceleration energy of 100 KeV and ion current 10 mA for 30, 60 and 90 minutes. The samples were subjected to the high temperature oxidation test by means of thermogravimetry in a magnetic suspension balance (MSB) at 500 °C for 5 hours. The scanning electron microscopy (SEM), X-ray diffractionmore » spectrometry (XRD) and Vickers Hardness measurement were used for sample characterization. The formation of ferro-nitride phase after implantation did not occur, however a thin layer considered to contain nitrogen interstitials was detected. The oxidation of both samples before and after implantation followed parabolic kinetics indicating inward growth of oxide scale characteristically due to diffusion of oxygen anions towards matrix surface. After oxidation test relativelly stable oxide scales were observed. Oxidation rates decreased proportionally with the increasing of implantation time due to the formation of oxide layer which is considered to be effectiv inhibitor for the oxygen diffusion.« less
Embryo-epithelium interactions during implantation at a glance.
Aplin, John D; Ruane, Peter T
2017-01-01
At implantation, with the acquisition of a receptive phenotype in the uterine epithelium, an initial tenuous attachment of embryonic trophectoderm initiates reorganisation of epithelial polarity to enable stable embryo attachment and the differentiation of invasive trophoblasts. In this Cell Science at a Glance article, we describe cellular and molecular events during the epithelial phase of implantation in rodent, drawing on morphological studies both in vivo and in vitro, and genetic models. Evidence is emerging for a repertoire of transcription factors downstream of the master steroidal regulators estrogen and progesterone that coordinate alterations in epithelial polarity, delivery of signals to the stroma and epithelial cell death or displacement. We discuss what is known of the cell interactions that occur during implantation, before considering specific adhesion molecules. We compare the rodent data with our much more limited knowledge of the human system, where direct mechanistic evidence is hard to obtain. In the accompanying poster, we represent the embryo-epithelium interactions in humans and laboratory rodents, highlighting similarities and differences, as well as depict some of the key cell biological events that enable interstitial implantation to occur. © 2017. Published by The Company of Biologists Ltd.
2018-01-01
ABSTRACT The use of polyelectrolyte multilayer microcapsules as carriers for fluorescent molecular probes is a prospective technique for monitoring the physiological characteristics of animal vasculature and interstitial environment in vivo. Polyelectrolyte microcapsules have many features that favor their use as implantable carriers of optical sensors, but little information is available on their interactions with complex living tissues, distribution or residence time following different routes of administration in the body of vertebrates. Using the common fish model, the zebrafish Danio rerio, we studied in vivo the distribution of non-biodegradable microcapsules covered with polyethylene glycol (PEG) over time in the adults and evaluated potential side effects of their delivery into the fish bloodstream and muscles. Fluorescent microcapsules administered into the bloodstream and interstitially (in concentrations that were sufficient for visualization and spectral signal recording) both showed negligible acute toxicity to the fishes during three weeks of observation. The distribution pattern of microcapsules delivered into the bloodstream was stable for at least one week, with microcapsules prevalent in capillaries-rich organs. However, after intramuscular injection, the phagocytosis of the microcapsules by immune cells was manifested, indicating considerable immunogenicity of the microcapsules despite PEG coverage. The long-term negative effects of chronic inflammation were also investigated in fish muscles by histological analysis. PMID:29305467
NASA Astrophysics Data System (ADS)
Behera, Rakesh K.; Watanabe, Taku; Andersson, David A.; Uberuaga, Blas P.; Deo, Chaitanya S.
2016-04-01
Oxygen interstitials in UO2+x significantly affect the thermophysical properties and microstructural evolution of the oxide nuclear fuel. In hyperstoichiometric Urania (UO2+x), these oxygen interstitials form different types of defect clusters, which have different migration behavior. In this study we have used kinetic Monte Carlo (kMC) to evaluate diffusivities of oxygen interstitials accounting for mono- and di-interstitial clusters. Our results indicate that the predicted diffusivities increase significantly at higher non-stoichiometry (x > 0.01) for di-interstitial clusters compared to a mono-interstitial only model. The diffusivities calculated at higher temperatures compare better with experimental values than at lower temperatures (< 973 K). We have discussed the resulting activation energies achieved for diffusion with all the mono- and di-interstitial models. We have carefully performed sensitivity analysis to estimate the effect of input di-interstitial binding energies on the predicted diffusivities and activation energies. While this article only discusses mono- and di-interstitials in evaluating oxygen diffusion response in UO2+x, future improvements to the model will primarily focus on including energetic definitions of larger stable interstitial clusters reported in the literature. The addition of larger clusters to the kMC model is expected to improve the comparison of oxygen transport in UO2+x with experiment.
NASA Astrophysics Data System (ADS)
Murkute, Punam; Ghadi, Hemant; Saha, Shantanu; Chavan, Vinayak; Chakrabarti, Subhananda
2018-03-01
ZnO has potential application in the field of short wavelength devices like LED's, laser diodes, UV detectors etc, because of its wide band gap (3.34 eV) and high exciton binding energy (60 meV). ZnO possess N-type conductivity due to presence of defects arising from oxygen and zinc interstitial vacancies. In order to achieve P-type or intrinsic carrier concentration an implantation study is preferred. In this report, we have varied phosphorous implantation time and studied its effect on optical as well structural properties of RF sputtered ZnO thin-films. Implantation was carried out using Plasma Immersion ion implantation technique for 10 and 20 s. These films were further annealed at 900°C for 10 s in oxygen ambient to activate phosphorous dopants. Low temperature photoluminescence (PL) spectra measured two distinct peaks at 3.32 and 3.199 eV for 20 s implanted sample annealed at 900°C. Temperature dependent PL measurement shows slightly blue shift in peak position from 18 K to 300 K. 3.199 eV peak can be attributed to donoracceptor pair (DAP) emission and 3.32 eV peak corresponds to conduction-band-to-acceptor (eA0) transition. High resolution x-ray diffraction revels dominant (002) peak from all samples. Increasing implantation time resulted in low peak intensity suggesting a formation of implantation related defects. Compression in C-axis with implantation time indicates incorporation of phosphorus in the formed film. Improvement in surface quality was observed from 20 s implanted sample which annealed at 900°C.
NASA Astrophysics Data System (ADS)
Krsjak, Vladimir; Degmova, Jarmila; Sojak, Stanislav; Slugen, Vladimir
2018-02-01
Fe-12 wt% Cr model alloy samples were implanted by 250 keV He2+ ions to three different fluencies (3 × 1017, 9 × 1017 and 1.5 × 1018 cm-2) at T < 100 °C. In a depth profile manner, the implantation impact according to defined peak profile was investigated using variable energy slow positrons, with the primary focus on the 2-13 dpa region. The obtained data were compared to published data on Optifer IX steel samples [1] irradiated in the frame of a two-years irradiation program of the Swiss Spallation Neutron Source. Bi-modal defect distribution represented by two defect components in positron lifetime spectrum reveals two distinct helium bubbles growth mechanisms. While at the lower helium production rate of the spallation environment, the bubbles grow primarily by migration and coalescence, at the high production rates of helium in the implanted samples, the results indicate this growth is driven by Ostwald ripening mechanism. A competitive growth process via emission of interstitial atoms (clusters) is discussed in terms of low-temperature He implantations.
In situ transmission electron microscopy He + implantation and thermal aging of nanocrystalline iron
Muntifering, Brittany R.; Fang, Youwu; Leff, Asher C.; ...
2016-10-04
Due to their high density of interfaces, nanostructured material are hypothesized to show a higher tolerance to radiation damage compared to conventional coarse-grained materials and are on interest for use in future nuclear reactors. In order to investigate the roles of vacancies, self-interstitials, and helium during defect accumulation, and the thermal evolution of such defects, a complex set of in situ TEM experiments were performed in nanocrystalline iron.
Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige
2017-08-01
To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p < 0.05). Interestingly, relative size of prostate apex in AP direction in sagittal image acquisitions compared to that in transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.
Klueh, Ulrike; Antar, Omar; Qiao, Yi; Kreutzer, Donald L.
2014-01-01
The concept of increased blood vessel (BV) density proximal to glucose sensors implanted in the interstitial tissue increases the accuracy and lifespan of sensors is accepted, despite limited existing experimental data. Interestingly, there is no previous data or even conjecture in the literature on the role of lymphatic vessels (LV) alone, or in combination with BV, in enhancing continuous glucose monitoring (CGM) in vivo. To investigate the impact of inducing vascular networks (BV and LV) at sites of glucose sensor implantation, we utilized adenovirus based local gene therapy of vascular endothelial cell growth factor-A (VEGF-A) to induce vessels at sensor implantation sites. The results of these studies demonstrated that 1) VEGF-A based local gene therapy increases vascular networks (blood vessels and lymphatic vessels) at sites of glucose sensor implantation; and 2) this local increase of vascular networks enhances glucose sensor function in vivo from 7 days to greater than 28 days post sensor implantation. This data provides “proof of concept” for the effective usage of local angiogenic factor (AF) gene therapy in mammalian models in an effort to extend CGM in vivo. It also supports the practice of a variety of viral and non-viral vectors as well as gene products (e.g. anti-inflammatory and anti-fibrosis genes) to engineer “implant friendly tissues” for the usage with implantable glucose sensors as well as other implantable devices. PMID:24243850
Winslow, Timothy B.; Eranki, Annu; Ullas, Soumya; Singh, Anurag K.; Repasky, Elizabeth A.; Sen, Arindam
2015-01-01
Purpose The tumour microenvironment is frequently hypoxic, poorly perfused, and exhibits abnormally high interstitial fluid pressure. These factors can significantly reduce efficacy of chemo and radiation therapies. The present study aims to determine whether mild systemic heating alters these parameters and improves response to radiation in human head and neck tumour xenografts in SCID mice. Materials and methods SCID mice were injected with FaDu cells (a human head and neck carcinoma cell line), or implanted with a resected patient head and neck squamous cell carcinoma grown as a xenograft, followed by mild systemic heating. Body temperature during heating was maintained at 39.5 ± 0.5 °C for 4 h. Interstitial fluid pressure (IFP), hypoxia and relative tumour perfusion in the tumours were measured at 2 and 24 h post-heating. Tumour vessel perfusion was measured 24 h post-heating, coinciding with the first dose of fractionated radiotherapy. Results Heating tumour-bearing mice resulted in significant decrease in intratumoural IFP, increased the number of perfused tumour blood vessels as well as relative tumour perfusion in both tumour models. Intratumoural hypoxia was also reduced in tumours of mice that received heat treatment. Mice bearing FaDu tumours heated 24 h prior to five daily radiation treatments exhibited significantly enhanced tumour response compared to tumours in control mice. Conclusions Mild systemic heating can significantly alter the tumour microenvironment of human head and neck tumour xenograft models, decreasing IFP and hypoxia while increasing microvascular perfusion. Collectively, these effects could be responsible for the improved response to radiotherapy. PMID:25986432
Winslow, Timothy B; Eranki, Annu; Ullas, Soumya; Singh, Anurag K; Repasky, Elizabeth A; Sen, Arindam
2015-01-01
The tumour microenvironment is frequently hypoxic, poorly perfused, and exhibits abnormally high interstitial fluid pressure. These factors can significantly reduce efficacy of chemo and radiation therapies. The present study aims to determine whether mild systemic heating alters these parameters and improves response to radiation in human head and neck tumour xenografts in SCID mice. SCID mice were injected with FaDu cells (a human head and neck carcinoma cell line), or implanted with a resected patient head and neck squamous cell carcinoma grown as a xenograft, followed by mild systemic heating. Body temperature during heating was maintained at 39.5 ± 0.5 °C for 4 h. Interstitial fluid pressure (IFP), hypoxia and relative tumour perfusion in the tumours were measured at 2 and 24 h post-heating. Tumour vessel perfusion was measured 24 h post-heating, coinciding with the first dose of fractionated radiotherapy. Heating tumour-bearing mice resulted in significant decrease in intratumoural IFP, increased the number of perfused tumour blood vessels as well as relative tumour perfusion in both tumour models. Intratumoural hypoxia was also reduced in tumours of mice that received heat treatment. Mice bearing FaDu tumours heated 24 h prior to five daily radiation treatments exhibited significantly enhanced tumour response compared to tumours in control mice. Mild systemic heating can significantly alter the tumour microenvironment of human head and neck tumour xenograft models, decreasing IFP and hypoxia while increasing microvascular perfusion. Collectively, these effects could be responsible for the improved response to radiotherapy.
Lopes, José António; Moreso, Francesc; Riera, Luis; Carrera, Marta; Ibernon, Meritxell; Fulladosa, Xavier; Grinyó, Josep Maria; Serón, Daniel
2005-04-01
Donor glomerulosclerosis, interstitial fibrosis, and fibrous intimal thickening correlate with graft outcome. We evaluate chronic lesions in donor biopsies according to Banff criteria and with a morphometric technique to ascertain their predictive value on graft outcome. We evaluated 77 cadaveric donor biopsies according to Banff criteria. Glomerulosclerosis was expressed as the percentage of global sclerotic glomeruli. The following morphometric parameters were obtained: cortical interstitial volume fraction (Vvint/c), cortical glomerular volume fraction (Vvglom/c), mean glomerular volume (Vg), mean and maximal intimal arterial volume fraction (Vvintima/art), and Vvintima/art of the largest artery. We evaluated the correlation of histologic lesions with delayed graft function, 3 months' glomerular filtration rate (GFR), and death-censored graft survival. Multivariate logistic regression showed that delayed graft function was associated with cv score [relative risk (RR) 4.2 and 95% CI 1.1 to 16.0) and glomerulosclerosis (RR 1.06 and 95% CI 1.01 to 1.13). Stepwise regression showed that Vvint/c and glomerulosclerosis were independent predictors of 3 months' GFR (R= 0.62, P= 0.0001). Repeated analysis not considering morphometric parameters showed that glomerulosclerosis, cv score and ci score were independent predictors of 3 months' GFR (R= 0.64, P= 0.0001). A donor chronic damage score was generated considering glomerulosclerosis, cv score and ci score. This score after adjusting for clinical variables was associated with 3 months' GFR (R= 0.71, P < 0.0001) and death-censored graft survival (RR 2.2 and 95% CI 1.3 to 3.7). Combined evaluation of donor glomerulosclerosis, chronic vascular and interstitial damage according to Banff criteria allows a precise prediction of graft outcome. Morphometric evaluation of donor biopsies does not improve the predictive value of semiquantitative grading.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamboglou, Nikolaos; Tselis, Nikolaos, E-mail: ntselis@hotmail.com; Baltas, Dimos
2013-03-01
Purpose: To report the clinical outcome of high-dose-rate (HDR) interstitial (IRT) brachytherapy (BRT) as sole treatment (monotherapy) for clinically localized prostate cancer. Methods and Materials: Between January 2002 and December 2009, 718 consecutive patients with clinically localized prostate cancer were treated with transrectal ultrasound (TRUS)-guided HDR monotherapy. Three treatment protocols were applied; 141 patients received 38.0 Gy using one implant in 4 fractions of 9.5 Gy with computed tomography-based treatment planning; 351 patients received 38.0 Gy in 4 fractions of 9.5 Gy, using 2 implants (2 weeks apart) and intraoperative TRUS real-time treatment planning; and 226 patients received 34.5 Gy,more » using 3 single-fraction implants of 11.5 Gy (3 weeks apart) and intraoperative TRUS real-time treatment planning. Biochemical failure was defined according to the Phoenix consensus, and toxicity was evaluated using Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 52.8 months. The 36-, 60-, and 96-month biochemical control and metastasis-free survival rates for the entire cohort were 97%, 94%, and 90% and 99%, 98%, and 97%, respectively. Toxicity was scored per event, with 5.4% acute grade 3 genitourinary and 0.2% acute grade 3 gastrointestinal toxicity. Late grade 3 genitourinary and gastrointestinal toxicities were 3.5% and 1.6%, respectively. Two patients developed grade 4 incontinence. No other instance of grade 4 or greater acute or late toxicity was reported. Conclusion: Our results confirm IRT-HDR-BRT is safe and effective as monotherapy for clinically localized prostate cancer.« less
Identification of photoluminescence P line in indium doped silicon as In{sub Si}-Si{sub i} defect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lauer, Kevin, E-mail: klauer@cismst.de; Möller, Christian; Schulze, Dirk
2015-01-15
Indium and carbon co-implanted silicon was investigated by low-temperature photoluminescence spectroscopy. A photoluminescence peak in indium doped silicon (P line) was found to depend on the position of a silicon interstitial rich region, the existence of a SiN{sub x}:H/SiO{sub x} stack and on characteristic illumination and annealing steps. These results led to the conclusion that silicon interstitials are involved in the defect and that hydrogen impacts the defect responsible for the P line. By applying an unique illumination and annealing cycle we were able to link the P line defect with a defect responsible for degradation of charge carrier lifetimemore » in indium as well as boron doped silicon. We deduced a defect model consisting of one acceptor and one silicon interstitial atom denoted by A{sub Si}-Si{sub i}, which is able to explain the experimental data of the P line as well as the light-induced degradation in indium and boron doped silicon. Using this model we identified the defect responsible for the P line as In{sub Si}-Si{sub i} in neutral charge state and C{sub 2v} configuration.« less
Wiig, Helge; Gyenge, Christina C; Tenstad, Olav
2005-01-01
Knowledge of macromolecular distribution volumes is essential in understanding fluid transport within normal and pathological tissues. In this study in vivo we determined the distribution volumes of several macromolecules, including one monoclonal antibody, in tumours and tested whether charges associated with the tumour extracellular matrix influence their available volumes. Steady state levels of the monoclonal antibody trastuzumab (Herceptin) (pI = 9.2), IgG (pI = 7.6) as well as native (pI = 5.0) and cationized albumin (pI = 7.6) were established in rats bearing dimethylbenzanthracene (DMBA)-induced mammary tumours by continuous infusion using osmotic minipumps. After a 5–7 day infusion period, the rats were nephrectomized and the extracellular volume was determined with 51Cr-labelled EDTA. Plasma volumes were measured with 125I-labelled human serum albumin or rat IgM in a separate series. Steady state concentrations of probes were determined in the interstitial fluid that was isolated by centrifugation from tumours or by post mortem wick implantation in the back skin. Calculations were made for interstitial fluid volume (Vi), along with the available (Va/Vi) and excluded (Ve/Vi) relative interstitial volume fractions. The Ve/Vi for the positively charged trastuzumab in tumours averaged 0.29 ± 0.03 (n = 16), a value which was significantly lower than the corresponding one for IgG of 0.36 ± 0.02 (n = 16). Native albumin was excluded from 38% of the tumour interstitial fluid, whereas cationization of albumin reduced the excluded volume by ∼50%. Our experiments suggest that the tumour interstitium acts as a negatively charged matrix and is an important factor in determining the macromolecular distribution volume. PMID:15994186
Wiig, Helge; Gyenge, Christina C; Tenstad, Olav
2005-09-01
Knowledge of macromolecular distribution volumes is essential in understanding fluid transport within normal and pathological tissues. In this study in vivo we determined the distribution volumes of several macromolecules, including one monoclonal antibody, in tumours and tested whether charges associated with the tumour extracellular matrix influence their available volumes. Steady state levels of the monoclonal antibody trastuzumab (Herceptin) (pI = 9.2), IgG (pI = 7.6) as well as native (pI = 5.0) and cationized albumin (pI = 7.6) were established in rats bearing dimethylbenzanthracene (DMBA)-induced mammary tumours by continuous infusion using osmotic minipumps. After a 5-7 day infusion period, the rats were nephrectomized and the extracellular volume was determined with 51Cr-labelled EDTA. Plasma volumes were measured with 125I-labelled human serum albumin or rat IgM in a separate series. Steady state concentrations of probes were determined in the interstitial fluid that was isolated by centrifugation from tumours or by post mortem wick implantation in the back skin. Calculations were made for interstitial fluid volume (Vi), along with the available (Va/Vi) and excluded (Ve/Vi) relative interstitial volume fractions. The Ve/Vi for the positively charged trastuzumab in tumours averaged 0.29 +/- 0.03 (n = 16), a value which was significantly lower than the corresponding one for IgG of 0.36 +/- 0.02 (n = 16). Native albumin was excluded from 38% of the tumour interstitial fluid, whereas cationization of albumin reduced the excluded volume by approximately 50%. Our experiments suggest that the tumour interstitium acts as a negatively charged matrix and is an important factor in determining the macromolecular distribution volume.
Interstitial space and collagen alterations of the developing rat diaphragm
NASA Technical Reports Server (NTRS)
Gosselin, L. E.; Martinez, D. A.; Vailas, A. C.; Sieck, G. C.
1993-01-01
The effect of growth on the relative interstitial space [%total cross-sectional area (CSA)] and collagen content of the rat diaphragm muscle was examined at postnatal ages of 0, 7, 14, and 21 days as well as in adult males. The proportion of interstitial space relative to total muscle CSA was determined by computerized image analysis of lectin-stained cross sections of diaphragm muscle. To assess collagen content and extent of collagen maturation (i.e., cross-linking), high-pressure liquid chromatography analysis was used to measure hydroxyproline concentration and the nonreducible collagen cross-link hydroxylysylpyridinoline (HP), respectively. At birth, interstitial space accounted for approximately 47% of total diaphragm muscle CSA. During postnatal growth, the relative contribution of interstitial space decreased such that by adulthood the interstitial space accounted for approximately 18% of total muscle CSA. The change in relative interstitial space occurred without a concomitant change in hydroxyproline concentration. However, the concentration of HP markedly increased with age such that the adult diaphragm contained approximately 17 times more HP than at birth. These results indicate that during development the relative CSA occupied by interstitial space decreases as muscle fiber size increases. However, the reduction in relative interstitial space is not associated with a change in collagen concentration. Thus collagen density in the interstitial space may increase with age. It is possible that the observed changes in relative interstitial space and collagen influence the passive length-force properties of the diaphragm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isoda, Taiga; Uematsu, Masashi; Itoh, Kohei M., E-mail: kitoh@appi.keio.ac.jp
2015-09-21
Si self-diffusion in the presence of end-of-range (EOR) defects is investigated using {sup nat}Si/{sup 28}Si isotope multilayers. The isotope multilayers were amorphized by Ge ion implantation, and then annealed at 800–950 °C. The behavior of Si self-interstitials is investigated through the {sup 30}Si self-diffusion. The experimental {sup 30}Si profiles show further enhancement of Si self-diffusion at the EOR defect region, in addition to the transient enhanced diffusion via excess Si self-interstitials by EOR defects. To explain this additional enhanced diffusion, we propose a model which takes into account enhanced diffusion by tensile strain originated from EOR defects. The calculation results basedmore » on this model have well reproduced the experimental {sup 30}Si profiles.« less
In vivo wireless ethanol vapor detection in the Wistar rat
Cheney, C. Parks; Srijanto, B.; Hedden, D. L.; Gehl, A.; Ferrell, T. L.; Schultz, J.; Engleman, E. A.; McBride, W. J.; O'Connor, S.
2009-01-01
Traditional alcohol studies measure blood alcohol concentration to elucidate the biomedical factors that contribute to alcohol abuse and alcoholism. These measurements require large and expensive equipment, are labor intensive, and are disruptive to the subject. To alleviate these problems, we have developed an implantable, wireless biosensor that is capable of measuring alcohol levels for up to six weeks. Ethanol levels were measured in vivo in the interstitial fluid of a Wistar rat after administering 1 g/kg and 2 g/kg ethanol by intraperitoneal (IP) injection. The data were transmitted wirelessly using a biosensor selective for alcohol detection. A low-power piezoresistive microcantilever sensor array was used with a polymer coating suitable for measuring ethanol concentrations at 100% humidity over several hours. A hydrophobic, vapor permeable nanopore membrane was used to screen liquid and ions while allowing vapor to pass to the sensor from the subcutaneous interstitial fluid. PMID:20161283
NASA Technical Reports Server (NTRS)
Holstege, G.; Cowie, R. J.
1989-01-01
Horseradish peroxidase was injected, or implanted unilaterally, into various levels of the spinal cord of anesthetized cats, to trace the distribution of projections to the spinal cord, of neurons in Field H of Forel, including the rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF), and the interstitial nucleus of Cajal with adjacent reticular formation (INC-RF). Results indicate that, unlike the neurons projecting to the extraocular muscle motoneurons, the major portion of the spinally projecting neurons are not located in the riMLF or INC proper, but in adjacent areas, i.e., the ventral and lateral parts of the caudal third of the Field H of Forel and in the INC-RF. Neurons in caudal Field H of Forel, project, via the ventral part of the ventral funicululs, to the lateral part of the upper cervical ventral horn.
Primary radiation therapy in the treatment of anal carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantril, S.T.; Green, J.P.; Schall, G.L.
1983-09-01
From 1966 to 1981, 47 patients with a diagnosis of anal carcinoma were irradiated. This group was composed of 23 males and 24 females, with age ranging from 38 to 84 years (average 64.4 years). Five patients were treated preoperatively and 34 were treated definitively with cancericidal doses of irradiation. Acute radiation reactions requiring a rest-break were noted in 28% of patients, but all were managed as outpatients without untoward chronic sequelae. Chronic complications were noted in 13 patients, including two patients who required colostomy for severe anal stenosis and two who required A-P resection for large painful ulcers. Twenty-eightmore » of 35 patients (80%) treated with irradiation alone have remained locally controlled without further treatment. An additional four have been salvaged by surgery. Only three patients had interstitial implants as part of their treatment course. Actuarial survival at five years for the N/sub 0/ patients and the group as a whole are 95.6 and 79.3%, respectively. It is concluded that external beam irradiation alone, properly fractionated to cancericidal doses, can control anal carcinoma with acceptable morbidity rates and without the use of either chemotherapy or interstitial implants in most cases. There is also a strong correlation suggesting that anal intercourse and male homosexuality play a significant role in the etiology of this disease.« less
Lilge, L.; Olivo, M. C.; Schatz, S. W.; MaGuire, J. A.; Patterson, M. S.; Wilson, B. C.
1996-01-01
The applicability and limitations of a photodynamic threshold model, used to describe quantitatively the in vivo response of tissues to photodynamic therapy, are currently being investigated in a variety of normal and malignant tumour tissues. The model states that tissue necrosis occurs when the number of photons absorbed by the photosensitiser per unit tissue volume exceeds a threshold. New Zealand White rabbits were sensitised with porphyrin-based photosensitisers. Normal brain or intracranially implanted VX2 tumours were illuminated via an optical fibre placed into the tissue at craniotomy. The light fluence distribution in the tissue was measured by multiple interstitial optical fibre detectors. The tissue concentration of the photosensitiser was determined post mortem by absorption spectroscopy. The derived photodynamic threshold values for normal brain are significantly lower than for VX2 tumour for all photosensitisers examined. Neuronal damage is evident beyond the zone of frank necrosis. For Photofrin the threshold decreases with time delay between photosensitiser administration and light treatment. No significant difference in threshold is found between Photofrin and haematoporphyrin derivative. The threshold in normal brain (grey matter) is lowest for sensitisation by 5 delta-aminolaevulinic acid. The results confirm the very high sensitivity of normal brain to porphyrin photodynamic therapy and show the importance of in situ light fluence monitoring during photodynamic irradiation. Images Figure 1 Figure 4 Figure 5 Figure 6 Figure 7 PMID:8562339
Structures and optical properties of \\text{H}_{2}^{+} -implanted GaN epi-layers
NASA Astrophysics Data System (ADS)
Li, B. S.; Wang, Z. G.
2015-06-01
The implantation damage build-up and optical properties of GaN epitaxial films under \\text{H}2+ ion implantation have been investigated by a combination of Rutherford backscattering in channeling geometry, Raman spectroscopy, UV-visible spectroscopy and transmission electron microscopy. GaN epitaxial films were implanted with 134 keV \\text{H}2+ ions to doses ranging from 3.75 × 1016 to 1.75 × 1017 \\text{H}2+ cm-2 at room temperature or the same dose of 1.5 × 1017 \\text{H}2+ cm-2 at room temperature, 573 and 723 K. The dependence of lattice disorder induced by \\text{H}2+ -implantation on the ion dose can be divided into a three-step damage process. A strong influence of the H concentration on the defect accumulation is discussed. The decrease in relative Ga disorder induced by \\text{H}2+ -implantation is linear with increasing implantation temperature. The absorption coefficient of GaN epitaxial films increases with increasing ion dose, leading to the decrease in Raman scattering spectra of Ga-N vibration. With increasing implantation doses up to 5 × 1016 \\text{H}2+ cm-2, nanoscale hydrogen bubbles are observed in the H deposition peak region. Interstitial-type dislocation loops are observed in the damaged layer located near the damage peak region, and the geometry of the dislocation loops produced by H implantation is analyzed. The surface layer is almost free of lattice disorder induced by \\text{H}2+ -implantation.
Gellynck, Karolien; Kodeck, Valérie; Van De Walle, Elke; Kersemans, Ken; De Vos, Filip; Declercq, Heidi; Dubruel, Peter; Vlaminck, Lieven
2015-01-01
Continuous glucose monitoring (CGM) is crucial in diabetic care. Long-term CGM systems however require an accurate sensor as well as a suitable measuring environment. Since large intravenous sensors are not feasible, measuring inside the interstitial fluid is considered the best alternative. This option, unfortunately, has the drawback of a lag time with blood glucose values. A good strategy to circumvent this is to enhance tissue integration and enrich the peri-implant vasculature. Implants of different optically transparent biomaterials (poly(methyl-methacrylate) [PMMA] and poly(dimethylsiloxane) [PDMS]) – enabling glucose monitoring in the near-infrared (NIR) spectrum – were surface-treated and subsequently implanted in goats at various implantation sites for up to 3 months. The overall in vivo biocompatibility, tissue integration, and vascularization at close proximity of the surfaces of these materials were assessed. Histological screening showed similar tissue reactions independent of the implantation site. No significant inflammation reaction was observed. Tissue integration and vascularization correlated, to some extent, with the biomaterial composition. A modification strategy, in which a vascular endothelial-cadherin antibody was coupled to the biomaterials surface through a dopamine layer, showed significantly enhanced vascularization 3 months after subcutaneous implantation. Our results suggest that the developed strategy enables the creation of tissue interactive NIR transparent packaging materials, opening the possibility of continuous glucose monitoring. PMID:25304314
Prokop, A; Kozlov, E; Nun Non, S; Dikov, M M; Sephel, G C; Whitsitt, J S; Davidson, J M
2001-01-01
We seek to improve existing methodologies for allogenic grafting of pancreatic islets. The lack of success of encapsulated transplanted islets inside the peritoneal cavity is presently attributed to poor vascularization of the implant. A thick, fibrotic capsule often surrounds the graft, limiting survival. We have tested the hypothesis that neovascularization of the graft material can be induced by the addition of proper angiogenic factors embedded within a polymeric coat. Biocompatible and nonresorbable meshes coated with hydrophilic polymers were implanted in rats and harvested after 1-, 6-, and 12-week intervals. The implant response was assessed by histological observations on the degree of vascularity, fibrosis, and inflammation. Macrostructural geometry of meshes was conducive to tissue ingrowth into the interstitial space between the mesh filaments. Hydrogel coating with incorporated acidic or basic FGF in an electrostatic complex with polyelectrolytes and/or with heparin provided a sustained slow release of the angiogenic growth factor. Anti-factor VIII and anti-collagen type IV antibodies and a GSL I-B4 lectin were used to measure the extent of vascularization. Vigorous and persistent vascularization radiated several hundred microns from the implant. The level of vascularization should provide a sufficient diffusion of nutrients and oxygen to implanted islets. Based on our observations, stable vascularization may require a sustained angiogenic signal to allow for the development of a permanent implant structure.
A miniaturized glucose biosensor for in vitro and in vivo studies.
Yang, Yang-Li; Huang, Jian-Feng; Tseng, Ta-Feng; Lin, Chia-Ching; Lou, Shyh-Liang
2008-01-01
A miniaturized wireless glucose biosensor has been developed to perform in vitro and in vivo studies. It consists of an external control subsystem and an implant sensing subsystem. The implant subsystem consists of a micro-processor, which coordinates circuitries of radio frequency, power regulator, command demodulator, glucose sensing trigger and signal read-out. Except for a set of sensing electrodes, the micro-processor, the circuitries and a receiving coil were hermetically sealed with polydimethylsiloxane. The electrode set is a substrate of silicon oxide coated with platinum, which includes a working electrode and a reference electrode. Glucose oxidase was immobilized on the surface of the working electrode. The implant subsystem bi-directionally communicates with the external subsystem via radio frequency technologies. The external subsystem wirelessly supplies electricity to power the implant, issues commands to the implant to perform tasks, receives the glucose responses detected by the electrode, and relays the response signals to a computer through a RS-232 connection. Studies of in vitro and in vivo were performed to evaluate the biosensor. The linear response of the biosensor is up to 15 mM of glucose in vitro. The results of in vivo study show significant glucose variations measured from the interstitial tissue fluid of a diabetes rat in fasting and non-fasting periods.
Directional interstitial brachytherapy from simulation to application
NASA Astrophysics Data System (ADS)
Lin, Liyong
Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the design optimization and construction of the first prototype directional source. Potential clinical applications and potential benefits of directional sources have been shown for prostate and breast tumors.
Dukhin, Stanislav S.; Labib, Mohamed E.
2016-01-01
Current drug delivery devices (DDD) are mainly based on the use of diffusion as the main transport process. Diffusion-driven processes can only achieve low release rate because diffusion is a slow process. This represents a serious obstacle in the realization of recent successes in the suppression of lymphatic metastasis and in the prevention of limb and organ transplant rejection. Surprisingly, it was overlooked that there is a more favorable drug release mode which can be achieved when a special DDD is implanted near lymphatics. This opportunity can be realized when the interstitial fluid flow penetrates a drug delivery device of proper design and allows such fluid to flow out of it. This design is based on hollow fibers loaded with drug and whose hydrodynamic permeability is much higher than that of the surrounding tissue. The latter is referred to as hollow fiber of high hydrodynamic permeability (HFHP). The interstitial flow easily penetrates the hollow fiber membrane as well as its lumen with a higher velocity than that in the adjacent tissue. The interstitial liquid stream entering the lumen becomes almost saturated with drug as it flows out of the HFHP. This is due to the drug powder dissolution in the lumens of HFHP which forms a strip of drug solution that crosses the interstitium and finally enters the lymphatics. This hydrodynamically-driven release (HDR) may exceed the concomitant diffusion-driven release (DDR) by one or even two orders of magnitude. The hydrodynamics of the two-compartment media is sufficient for developing the HDR theory which is detailed in this paper. Convective diffusion theory for two compartments (membrane of hollow fiber and adjacent tissue) is required for exact quantification when a small contribution of DDR to predominating HDR is present. Hence, modeling is important for HDR which would lead to establishing a new branch in physico-chemical hydrodynamics. The release rate achieved with the use of HFHP increases proportional to the number of hollow fibers in the fabric employed in drug delivery. Based on this contribution, it is now possible to simultaneously provide high release rates and long release durations, thus overcoming a fundamental limitation in drug delivery. Perhaps this breakthrough in long-term drug delivery has potential applications in targeting lymphatics and in treating cancer and cancer metastasis without causing the serious side effects of systemic drugs. PMID:28579697
Sharma, Vinit K.; Herklotz, Andreas; Ward, Thomas Zac; ...
2017-09-11
Ion implantation has been widely used in the semiconductor industry for decades to selectively control electron/hole doping for device applications. Recently, experimental studies on ion implantation into more structurally and electronically complex materials have been undertaken in which defect generation has been used to control a variety of functional phenomena. Of particular interest, are recent findings demonstrating that low doses of low energy helium ions into single crystal films can be used to tailor the structural properties. These initial experimental studies have shown that crystal symmetry can be continuously controlled by applying increasingly large doses of He ions into amore » crystal. The observed changes in lattice structure were then observed to correlate with functional changes, such as metal-insulator transition temperature2 and optical bandgap3. In these preliminary experimental studies, changes to lattice expansion was proposed to be the direct result of chemical pressure originating predominantly from the implanted He applying chemical pressure at interstitial sites. However, the influence of possible secondary knock-on damage arising from the He atoms transferring energy to the lattice through nuclear-nuclear collision with the crystal lattice remains largely unaddressed. In this work, we focus on a SrRuO3 model system to provide a comprehensive examination of the impact of common defects on structural and electronic properties, obtain calculated defect formation energies, and define defect migration barriers. Our model indicates that, while interstitial He can modify the crystal properties, a dose significantly larger than those reported in experimental studies would be required. The true origin of the observed structural changes is likely the result of a combination of secondary defects created during He implantation. Of particular importance, we observe that different defect types can generate greatly varied local electronic structures and that the formation energies and migration energy barriers vary by defect type. Thus, we may have identified a new method of selectively inducing controlled defect complexes into single crystal materials. Development of this approach would have a broad impact on both our ability to probe specific defect contributions in fundamental studies and allow a new level of control over functional properties driven by specific defect complexes.« less
NASA Astrophysics Data System (ADS)
Dupré, C.; Ernst, T.; Hartmann, J.-M.; Andrieu, F.; Barnes, J.-P.; Rivallin, P.; Faynot, O.; Deleonibus, S.; Fazzini, P. F.; Claverie, A.; Cristoloveanu, S.; Ghibaudo, G.; Cristiano, F.
2007-11-01
Based on electrical measurements and transmission electron microscopy (TEM) imaging, we propose an explanation for the electron and hole mobility degradation with gate length reduction in metal-oxide-semiconductor field effect transistors (MOSFETs). We demonstrate that ion implantation, normally used for source/drain doping, is responsible for transport degradation for short-channel devices. Implantation impact on electrons and holes mobility was investigated both on silicon-on-insulator (SOI) and tensile strained silicon-on-insulator (sSOI) substrates. Wafers with ultrathin Si films (from 8 to 35 nm) were Ge implanted at 3 keV and various concentrations (from 5×1014 to 2×1015 atoms cm-2), then annealed at 600 °C for 1 h. Secondary ion mass spectrometry enabled us to quantify the Ge-implanted atoms concentrations. The end-of-range defects impact on mobility was investigated with the pseudo-MOSFET technique. Measurements showed a mobility decrease as the implantation dose increased. We demonstrated that sSOI mobility is more sensitive to implantation than SOI mobility, without any implantation-induced strain relaxation in sSOI (checked using the ultraviolet Raman technique). A 36% (25%) holes (electrons) mobility degradation was measured for sSOI, while SOI presented a 21% mobility degradation for holes and 5% for electrons. Finally, the electrical results were compared with morphological studies. Plan-view TEM showed the presence of interstitial defects formed during ion implantation and annealing. The defect density was estimated to be two times higher in sSOI than in SOI, which is in full agreement with electrical results mentioned before. The results are relevant for the optimization of the source and drain regions of advanced nanoscale SOI and sSOI transistors.
An ultrasonically powered implantable micro-oxygen generator (IMOG).
Maleki, Teimour; Cao, Ning; Song, Seung Hyun; Kao, Chinghai; Ko, Song-Chu Arthur; Ziaie, Babak
2011-11-01
In this paper, we present an ultrasonically powered implantable micro-oxygen generator (IMOG) that is capable of in situ tumor oxygenation through water electrolysis. Such active mode of oxygen generation is not affected by increased interstitial pressure or abnormal blood vessels that typically limit the systemic delivery of oxygen to hypoxic regions of solid tumors. Wireless ultrasonic powering (2.15 MHz) was employed to increase the penetration depth and eliminate the directional sensitivity associated with magnetic methods. In addition, ultrasonic powering allowed for further reduction in the total size of the implant by eliminating the need for a large area inductor. IMOG has an overall dimension of 1.2 mm × 1.3 mm × 8 mm, small enough to be implanted using a hypodermic needle or a trocar. In vitro and ex vivo experiments showed that IMOG is capable of generating more than 150 μA which, in turn, can create 0.525 μL/min of oxygen through electrolytic disassociation. In vivo experiments in a well-known hypoxic pancreatic tumor models (1 cm (3) in size) also verified adequate in situ tumor oxygenation in less than 10 min.
Onsurathum, Sudarat; Haonon, Ornuma; Pinlaor, Porntip; Pairojkul, Chawalit; Khuntikeo, Narong; Thanan, Raynoo; Roytrakul, Sittiruk; Pinlaor, Somchai
2018-04-01
Tumor interstitial fluid contains tumor-specific proteins that may be useful biomarkers for cancers. In this study, we identified proteins present in cholangiocarcinoma interstitial fluid. Proteins derived from three samples of tumor interstitial fluid and paired samples of adjacent normal interstitial fluid from cholangiocarcinoma patients were subjected to two-dimensional liquid chromatography with tandem mass spectrometry. Candidate proteins were selected based on a greater than twofold change in expression levels between tumor interstitial fluid and normal interstitial fluid. Upregulation of six proteins in tumor interstitial fluid, including S100 calcium binding protein A6 (S100A6), S100 calcium binding protein A9, aldo-keto reductase family 1 member C4, neuropilin-1, 14-3-3 zeta/delta, and triosephosphate isomerase was assessed by western blot and immunohistochemistry. Their potential as markers was evaluated in human cholangiocarcinoma tissue arrays, and in serum using enzyme-linked immunosorbent assay. Expression of S100A6 was higher in tumor interstitial fluid than in normal interstitial fluid and showed the highest positive rate (98.96%) in cholangiocarcinoma tissues. Serum levels of S100A6 did not differ between cholangitis and cholangiocarcinoma patients, but were significantly higher than in healthy individuals ( p < 0.0001). In cholangiocarcinoma cases, S100A6 level was associated with vascular invasion ( p = 0.007) and could distinguish cholangiocarcinoma patients from healthy individuals as effectively as the carbohydrate antigen 19-9. In addition, potential for drug treatment targeting S100A6 and other candidate proteins was also demonstrated using STITCH analysis. In conclusion, proteomics analysis of tumor interstitial fluid could be a new approach for biomarker discovery, and S100A6 is a potential risk marker for screening of cholangiocarcinoma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darcy, Eric; Keyser, Matthew
The Internal Short Circuit (ISC) device enables critical battery safety verification. With the aluminum interstitial heat sink between the cells, normal trigger cells cannot be driven into thermal runaway without excessive temperature bias of adjacent cells. With an implantable, on-demand ISC device, thermal runaway tests show that the conductive heat sinks protected adjacent cells from propagation. High heat dissipation and structural support of Al heat sinks show high promise for safer, higher performing batteries.
2017-10-01
Overactive bladder is a condition resulting from disruption of the normal micturition process. It is a syndrome complex characterized by urinary...from our pilot study in patients with another model of bladder dysfunction (i.e. interstitial cystitis/painful bladder syndrome (IC/PBS)) implanted...increased risk with exposure to ONAboNT-A including diagnosed myasthenia gravis, Eaton-Lambert syndrome or amyotrophic lateral sclerosis. 17
Correlation of gene expression with bladder capacity in interstitial cystitis/bladder pain syndrome.
Colaco, Marc; Koslov, David S; Keys, Tristan; Evans, Robert J; Badlani, Gopal H; Andersson, Karl-Erik; Walker, Stephen J
2014-10-01
Interstitial cystitis and bladder pain syndrome are terms used to describe a heterogeneous chronic pelvic and bladder pain disorder. Despite its significant prevalence, our understanding of disease etiology is poor. We molecularly characterized interstitial cystitis/bladder pain syndrome and determined whether there are clinical factors that correlate with gene expression. Bladder biopsies from female subjects with interstitial cystitis/bladder pain syndrome and female controls without signs of the disease were collected and divided into those with normal and low anesthetized bladder capacity, respectively. Samples then underwent RNA extraction and microarray assay. Data generated by these assays were analyzed using Omics Explorer (Qlucore, Lund, Sweden), GeneSifter® Analysis Edition 4.0 and Ingenuity® Pathway Analysis to determine similarity among samples within and between groups, and measure differentially expressed transcripts unique to each phenotype. A total of 16 subjects were included in study. Principal component analysis and unsupervised hierarchical clustering showed clear separation between gene expression in tissues from subjects with low compared to normal bladder capacity. Gene expression in tissue from patients with interstitial cystitis/bladder pain syndrome who had normal bladder capacity did not significantly differ from that in controls without interstitial cystitis/bladder pain syndrome. Pairwise analysis revealed that pathways related to inflammatory and immune response were most involved. Microarray analysis provides insight into the potential pathological condition underlying interstitial cystitis/bladder pain syndrome. This pilot study shows that patients with this disorder who have low compared to normal bladder capacity have significantly different molecular characteristics, which may reflect a difference in disease pathophysiology. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Moiduddin, Khaja
2018-02-01
The traditional methods of metallic bone implants are often dense and suffer from adverse reactions, biomechanical mismatch and lack of adequate space for new bone tissue to grow into the implant. The objective of this study is to evaluate the customized porous cranial implant with mechanical properties closer to that of bone and to improve the aesthetic outcome in cranial surgery with precision fitting for a better quality of life. Two custom cranial implants (bulk and porous) are digitally designed based on the Digital Imaging and Communications in Medicine files and fabricated using additive manufacturing. Initially, the defective skull model and the implant were fabricated using fused deposition modeling for the purpose of dimensional validation. Subsequently, the implant was fabricated using titanium alloy (Ti6Al4V extra low interstitial) by electron beam melting technology. The electron beam melting-produced body diagonal node structure incorporated in cranial implant was evaluated based on its mechanical strength and structural characterization. The results show that the electron beam melting-produced porous cranial implants provide the necessary framework for the bone cells to grow into the pores and mimic the architecture and mechanical properties closer to the region of implantation. Scanning electron microscope and micro-computed tomography scanning confirm that the produced porous implants have a highly regular pattern of porous structure with a fully interconnected network channel without any internal defect and voids. The physical properties of the titanium porous structure, containing the compressive strength of 61.5 MPa and modulus of elasticity being 1.20 GPa, represent a promising means of reducing stiffness and stress-shielding effect on the surrounding bone. This study reveals that the use of porous structure in cranial reconstruction satisfies the need of lighter implants with an adequate mechanical strength and structural characteristics, thus restoring better functionality and aesthetic outcomes for the patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riofrio, D; Luan, S; Zhou, J
Purpose: In prostate HDR brachytherapy, interstitial implants are placed manually on the fly. The aim for this research is to develop a computer algorithm to find optimal and reliable implant trajectories using minimal number of implants. Methods: Our new algorithm mainly uses these key ideas: (1) positive charged static particles are uniformly placed on the surface of prostate and critical structures such as urethra, bladder, and rectum. (2) Positive charged kinetic particles are placed at a cross-section of the prostate with an initial velocity parallel to the principal implant direction. (3) The kinetic particles move through the prostate, interacting withmore » each other, spreading out, while staying away from the prostate surface and critical structures. The initial velocity ensures that the trajectories observe the curvature constraints of typical implant procedures. (4) The finial trajectories of kinetic particles are smoothed using a third-degree polynomial regression, which become the implant trajectories. (5) The dwelling times and final dose distribution are calculated using least-distance programming. Results: (1) We experimented with previously treated cases. Our plan achieves all prescription goals while reducing the number of implants by 41%! Our plan also has less uniform target dose, which implies a higher dose is delivered to the prostate. (2) We expect future implant procedures will be performed under the guidance of such pre-calculated trajectories. To assess the applicability, we randomly perturb the tracks to mimic the manual implant errors. Our studies showed the impact of these perturbations are negligible, which is compensated by the least distance programming. Conclusions: We developed a new inverse planning system for prostate HDR therapy that can find optimal implant trajectories while minimizing the number of implants. For future work, we plan to integrate our new inverse planning system with an existing needle tracking system.« less
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.
2011-03-01
A clinical treatment delivery platform has been developed and is being evaluated in a clinical pilot study for providing 3D controlled hyperthermia with catheter-based ultrasound applicators in conjunction with high dose rate (HDR) brachytherapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within HDR brachytherapy implants during radiation therapy in the treatment of cervix and prostate. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length × 180 deg and 3-4 cm × 360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers × dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and six prostate implants. 100 % of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target volume (HTV) and clinical target volume (CTV) are reported. Catheter-based ultrasound hyperthermia with HDR appears feasible with therapeutic temperature coverage of the target volume within the prostate or cervix while sparing surrounding more sensitive regions.
Ungprasert, Patompong; Wilton, Katelynn M; Ernste, Floranne C; Kalra, Sanjay; Crowson, Cynthia S; Rajagopalan, Srinivasan; Bartholmai, Brian J
2017-10-01
To evaluate the correlation between measurements from quantitative thoracic high-resolution CT (HRCT) analysis with "Computer-Aided Lung Informatics for Pathology Evaluation and Rating" (CALIPER) software and measurements from pulmonary function tests (PFTs) in patients with idiopathic inflammatory myopathies (IIM)-associated interstitial lung disease (ILD). A cohort of patients with IIM-associated ILD seen at Mayo Clinic was identified from medical record review. Retrospective analysis of HRCT data and PFTs at baseline and 1 year was performed. The abnormalities in HRCT were quantified using CALIPER software. A total of 110 patients were identified. At baseline, total interstitial abnormalities as measured by CALIPER, both by absolute volume and by percentage of total lung volume, had a significant negative correlation with diffusing capacity for carbon monoxide (DLCO), total lung capacity (TLC), and oxygen saturation. Analysis by subtype of interstitial abnormality revealed significant negative correlations between ground glass opacities (GGO) and reticular density (RD) with DLCO and TLC. At one year, changes of total interstitial abnormalities compared with baseline had a significant negative correlation with changes of TLC and oxygen saturation. A negative correlation between changes of total interstitial abnormalities and DLCO was also observed, but it was not statistically significant. Analysis by subtype of interstitial abnormality revealed negative correlations between changes of GGO and RD and changes of DLCO, TLC, and oxygen saturation, but most of the correlations did not achieve statistical significance. CALIPER measurements correlate well with functional measurements in patients with IIM-associated ILD.
Radiation tolerance of nanocrystalline ceramics: insights from Yttria Stabilized Zirconia.
Dey, Sanchita; Drazin, John W; Wang, Yongqiang; Valdez, James A; Holesinger, Terry G; Uberuaga, Blas P; Castro, Ricardo H R
2015-01-13
Materials for applications in hostile environments, such as nuclear reactors or radioactive waste immobilization, require extremely high resistance to radiation damage, such as resistance to amorphization or volume swelling. Nanocrystalline materials have been reported to present exceptionally high radiation-tolerance to amorphization. In principle, grain boundaries that are prevalent in nanomaterials could act as sinks for point-defects, enhancing defect recombination. In this paper we present evidence for this mechanism in nanograined Yttria Stabilized Zirconia (YSZ), associated with the observation that the concentration of defects after irradiation using heavy ions (Kr(+), 400 keV) is inversely proportional to the grain size. HAADF images suggest the short migration distances in nanograined YSZ allow radiation induced interstitials to reach the grain boundaries on the irradiation time scale, leaving behind only vacancy clusters distributed within the grain. Because of the relatively low temperature of the irradiations and the fact that interstitials diffuse thermally more slowly than vacancies, this result indicates that the interstitials must reach the boundaries directly in the collision cascade, consistent with previous simulation results. Concomitant radiation-induced grain growth was observed which, as a consequence of the non-uniform implantation, caused cracking of the nano-samples induced by local stresses at the irradiated/non-irradiated interfaces.
Radiation Tolerance of Nanocrystalline Ceramics: Insights from Yttria Stabilized Zirconia
Dey, Sanchita; Drazin, John W.; Wang, Yongqiang; Valdez, James A.; Holesinger, Terry G.; Uberuaga, Blas P.; Castro, Ricardo H. R.
2015-01-01
Materials for applications in hostile environments, such as nuclear reactors or radioactive waste immobilization, require extremely high resistance to radiation damage, such as resistance to amorphization or volume swelling. Nanocrystalline materials have been reported to present exceptionally high radiation-tolerance to amorphization. In principle, grain boundaries that are prevalent in nanomaterials could act as sinks for point-defects, enhancing defect recombination. In this paper we present evidence for this mechanism in nanograined Yttria Stabilized Zirconia (YSZ), associated with the observation that the concentration of defects after irradiation using heavy ions (Kr+, 400 keV) is inversely proportional to the grain size. HAADF images suggest the short migration distances in nanograined YSZ allow radiation induced interstitials to reach the grain boundaries on the irradiation time scale, leaving behind only vacancy clusters distributed within the grain. Because of the relatively low temperature of the irradiations and the fact that interstitials diffuse thermally more slowly than vacancies, this result indicates that the interstitials must reach the boundaries directly in the collision cascade, consistent with previous simulation results. Concomitant radiation-induced grain growth was observed which, as a consequence of the non-uniform implantation, caused cracking of the nano-samples induced by local stresses at the irradiated/non-irradiated interfaces. PMID:25582769
Rodríguez, S; Arenas, M; Gutierrez, C; Richart, J; Perez-Calatayud, J; Celada, F; Santos, M; Rovirosa, A
2018-04-01
Clinical indications of brachytherapy in non-melanoma skin cancers, description of applicators and dosimetry recommendations are described based on the literature review, clinical practice and experience of Spanish Group of Brachytherapy and Spanish Society of Medical Physics reported in the XIV Annual Consensus Meeting on Non Melanoma Skin Cancer Brachytherapy held in Benidorm, Alicante (Spain) on October 21st, 2016. All the recommendations for which consensus was achieved are highlighted in blue. Regular and small surfaces may be treated with Leipzig, Valencia, flap applicators or electronic brachytherapy (EBT). For irregular surfaces, customized molds or interstitial implants should be employed. The dose is prescribed at a maximum depth of 3-4 mm of the clinical target volume/planning target volume (CTV/PTV) in all cases except in flaps or molds in which 5 mm is appropriate. Interstitial brachytherapy should be used for CTV/PTV >5 mm. Different total doses and fraction sizes are used with very similar clinical and toxicity results. Hypofractionation is very useful twice or 3 times a week, being comfortable for patients and practical for Radiotherapy Departments. In interstitial brachytherapy 2 fractions twice a day are applied.
Jahnavi, S; Saravanan, U; Arthi, N; Bhuvaneshwar, G S; Kumary, T V; Rajan, S; Verma, R S
2017-04-01
Major challenge in heart valve tissue engineering for paediatric patients is the development of an autologous valve with regenerative capacity. Hybrid tissue engineering approach is recently gaining popularity to design scaffolds with desired biological and mechanical properties that can remodel post implantation. In this study, we fabricated aligned nanofibrous Bio-Hybrid scaffold made of decellularized bovine pericardium: polycaprolactone-chitosan with optimized polymer thickness to yield the desired biological and mechanical properties. CD44 + , αSMA + , Vimentin + and CD105 - human valve interstitial cells were isolated and seeded on these Bio-Hybrid scaffolds. Subsequent biological evaluation revealed interstitial cell proliferation with dense extra cellular matrix deposition that indicated the viability for growth and proliferation of seeded cells on the scaffolds. Uniaxial mechanical tests along axial direction showed that the Bio-Hybrid scaffolds has at least 20 times the strength of the native valves and its stiffness is nearly 3 times more than that of native valves. Biaxial and uniaxial mechanical studies on valve interstitial cells cultured Bio-Hybrid scaffolds revealed that the response along the axial and circumferential direction was different, similar to native valves. Overall, our findings suggest that Bio-Hybrid scaffold is a promising material for future development of regenerative heart valve constructs in children. Copyright © 2016 Elsevier B.V. All rights reserved.
Radiation tolerance of nanocrystalline ceramics: Insights from yttria stabilized zirconia
Dey, Sanchita; Drazin, John W.; Wang, Yongqiang; ...
2015-01-13
Materials for applications in hostile environments, such as nuclear reactors or radioactive waste immobilization, require extremely high resistance to radiation damage, such as resistance to amorphization or volume swelling. Nanocrystalline materials have been reported to present exceptionally high radiation-tolerance to amorphization. In principle, grain boundaries that are prevalent in nanomaterials could act as sinks for point-defects, enhancing defect recombination. In this paper we present evidence for this mechanism in nanograined Yttria Stabilized Zirconia (YSZ), associated with the observation that the concentration of defects after irradiation using heavy ions (Kr⁺, 400 keV) is inversely proportional to the grain size. HAADF imagesmore » suggest the short migration distances in nanograined YSZ allow radiation induced interstitials to reach the grain boundaries on the irradiation time scale, leaving behind only vacancy clusters distributed within the grain. Because of the relatively low temperature of the irradiations and the fact that interstitials diffuse thermally more slowly than vacancies, this result indicates that the interstitials must reach the boundaries directly in the collision cascade, consistent with previous simulation results. Concomitant radiation-induced grain growth was observed which, as a consequence of the non-uniform implantation, caused cracking of the nano-samples induced by local stresses at the irradiated/non-irradiated interfaces.« less
Group III impurities Si interstitials interaction caused by ion irradiation
NASA Astrophysics Data System (ADS)
Romano, L.; Piro, A. M.; De Bastiani, R.; Grimaldi, M. G.; Rimini, E.
2006-01-01
The off-lattice displacement of substitutional impurities (B, Ga) in Si caused by irradiation with energetic light ion beams has been investigated. Samples have been prepared by solid phase epitaxy (SPE) of pre-amorphized Si subsequently implanted with B and Ga at a concentration of about 1 × 1020 at/cm3 confined in a 300 nm thick surface region. The off-lattice displacement of the impurities was induced at room temperature (RT) by irradiation with high energy (>600 keV) light ion beams (H, He) and detected by the channelling technique along different axes, using the 11B(p,α)8Be reaction and standard RBS, for B and Ga, respectively. The normalized channelling yield χ of the impurity signal increases with the ion fluence, indicating a progressive off-lattice displacement of the dopant during irradiation, until it saturates at χF < 1 suggesting a non-random displacement of the dopant. Although the precise value of χF depends on the channelling direction and dopant species, the off-lattice displacement rate, deduced from the χ versus interstitial fluence curve, only depends on the excess of Si self-interstitials (SiI) generated by the irradiating beam through a parameter σ that can be interpreted as an effective cross-section for the impurity-SiI interaction.
Improved intratumoral nanoparticle extravasation and penetration by mild hyperthermia.
Li, Li; ten Hagen, Timo L M; Bolkestein, Michiel; Gasselhuber, Astrid; Yatvin, Jeremy; van Rhoon, Gerard C; Eggermont, Alexander M M; Haemmerich, Dieter; Koning, Gerben A
2013-04-28
Accumulation of nanoparticles in solid tumors depends on their extravasation. However, vascular permeability is very heterogeneous within a tumor and among different tumor types, hampering efficient delivery. Local hyperthermia at a tumor can improve nanoparticle delivery by increasing tumor vasculature permeability, perfusion and interstitial fluid flow. The aim of this study is to investigate hyperthermia conditions required to improve tumor vasculature permeability, subsequent liposome extravasation and interstitial penetration in 4 tumor models. Tumors are implanted in dorsal skin flap window chambers and observed for liposome (~85 nm) accumulation by intravital confocal microscopy. Local hyperthermia at 41°C for 30 min initiates liposome extravasation through permeable tumor vasculature in all 4 tumor models. A further increase in nanoparticle extravasation occurs while continuing heating to 1h, which is a clinically relevant duration. After hyperthermia, the tumor vasculature remains permeable for 8h. We visualize gaps in the endothelial lining of up to 10 μm induced by HT. Liposomes extravasate through these gaps and penetrate into the interstitial space to at least 27.5 μm in radius from the vessel walls. Whole body optical imaging confirms HT induced extravasation while liposome extravasation was absent at normothermia. In conclusion, a thermal dose of 41°C for 1h is effective to induce long-lasting permeable tumor vasculature for liposome extravasation and interstitial penetration. These findings hold promise for improved intratumoral drug delivery upon application of local mild hyperthermia prior to administration of nanoparticle-based drug delivery systems. Copyright © 2013 Elsevier B.V. All rights reserved.
Tseng, Yuan-Yun; Su, Chen-Hsing; Yang, Shun-Tai; Huang, Yin-Chen; Lee, Wei-Hwa; Wang, Yi-Chuan; Liu, Shou-Cheng; Liu, Shih-Jung
2016-09-13
Glioblastoma multiforme (GBM), the most prevalent and malignant form of a primary brain tumour, is resistant to chemotherapy. In this study, we concurrently loaded three chemotherapeutic agents [bis-chloroethylnitrosourea, irinotecan, and cisplatin; BIC] into 50:50 poly[(d,l)-lactide-co-glycolide] (PLGA) nanofibres and an antiangiogenic agent (combretastatin) into 75:25 PLGA nanofibres [BIC and combretastatin (BICC)/PLGA]. The BICC/PLGA nanofibrous membranes were surgically implanted onto the brain surfaces of healthy rats for conducting pharmacodynamic studies and onto C6 glioma-bearing rats for estimating the therapeutic efficacy.The chemotherapeutic agents were rapidly released from the 50:50 PLGA nanofibres after implantation, followed by the release of combretastatin (approximately 2 weeks later) from the 75:25 PLGA nanofibres. All drug concentrations remained higher in brain tissues than in the blood for more than 8 weeks. The experimental results, including attenuated malignancy, retarded tumour growth, and prolonged survival in tumour-bearing rats, demonstrated the efficacy of the BICC/PLGA nanofibrous membranes. Furthermore, the efficacy of BIC/PLGA and BICC/PLGA nanofibrous membranes was compared. The BICC/PLGA nanofibrous membranes more efficiently retarded the tumour growth and attenuated the malignancy of C6 glioma-bearing rats. Moreover, the addition of combretastatin did not significantly change the drug release behaviour of the BIC/PLGA nanofibrous membranes. The present advanced and novel interstitial chemotherapy and targeted treatment provide a potential strategy and regimen for treating GBM.
Qualification of Ti6Al4V ELI Alloy Produced by Laser Powder Bed Fusion for Biomedical Applications
NASA Astrophysics Data System (ADS)
Yadroitsev, I.; Krakhmalev, P.; Yadroitsava, I.; Du Plessis, A.
2018-03-01
Rectangular Ti6Al4V extralow interstitials (ELI) samples were manufactured by laser powder bed fusion (LPBF) in vertical and horizontal orientations relative to the build platform and subjected to various heat treatments. Detailed analyses of porosity, microstructure, residual stress, tensile properties, fatigue, and fracture surfaces were performed based on x-ray micro-computed tomography, scanning electron microscopy, and x-ray diffraction methods. The types of fracture and the tensile fracture mechanisms of the LPBF Ti6Al4V ELI alloy were also studied. Detailed analysis of the microstructure and the corresponding mechanical properties were compared against standard specifications for conventional Ti6Al4V alloy for use in surgical implant applications. Conclusions regarding the mechanical properties and heat treatment of LPBF Ti6Al4V ELI for biomedical applications are made.
Analysis of Dissolved Organic Nutrients in the Interstitial Water of Natural Biofilms.
Tsuchiya, Yuki; Eda, Shima; Kiriyama, Chiho; Asada, Tomoya; Morisaki, Hisao
2016-07-01
In biofilms, the matrix of extracellular polymeric substances (EPSs) retains water in the interstitial region of the EPS. This interstitial water is the ambient environment for microorganisms in the biofilms. The nutrient condition in the interstitial water may affect microbial activity in the biofilms. In the present study, we measured the concentrations of dissolved organic nutrients, i.e., saccharides and proteins, contained in the interstitial water of biofilms formed on the stones. We also analyzed the molecular weight distribution, chemical species, and availability to bacteria of some saccharides in the interstitial water. Colorimetric assays showed that the concentrations of saccharides and proteins in the biofilm interstitial water were significantly higher (ca. 750 times) than those in the surrounding lake waters (p < 0.05). Chromatographic analyses demonstrated that the saccharides in the interstitial waters were mainly of low molecular-weight saccharides such as glucose and maltose, while proteins in the interstitial water were high molecular-weight proteins (over 7000 Da). Bacterial growth and production of EPS occurred simultaneously with the decrease in the low molecular-weight saccharide concentrations when a small portion of biofilm suspension was inoculated to the collected interstitial water, suggesting that the dissolved saccharides in the interstitial water support bacterial growth and formation of biofilms.
Radiation control in the intensive care unit for high intensity iridium-192 brain implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sewchand, W.; Drzymala, R.E.; Amin, P.P.
A bedside lead cubicle was designed to minimize the radiation exposure of intensive care unit staff during routine interstitial brain irradiation by removable, high intensity iridium-192. The cubicle shields the patient without restricting intensive care routines. The design specifications were confirmed by exposure measurements around the shield with an implanted anthropomorphic phantom simulating the patient situation. The cubicle reduces the exposure rate around an implant patient by as much as 90%, with the exposure level not exceeding 0.1 mR/hour/mg of radium-equivalent /sup 192/Ir. Evaluation of data accumulated for the past 3 years has shown that the exposure levels of individualmore » attending nurses are 0.12 to 0.36 mR/mg of radium-equivalent /sup 192/Ir per 12-hour shift. The corresponding range for entire nursing teams varies between 0.18 and 0.26. A radiation control index (exposure per mg of radium-equivalent /sup 192/Ir per nurse-hour) is thus defined for individual nurses and nursing teams; this index is a significant guide to the planning of nurse rotations for brain implant patients with various /sup 192/Ir loads. The bedside shield reduces exposure from /sup 192/Ir implants by a factor of about 20, as expected, and the exposure from the lower energy radioisotope iodine-125 is barely detectable.« less
/sup 125/I interstitial implants in the RIF-1 murine flank tumor: an animal model for brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, M.; Gutin, P.H.; Weaver, D.A.
1982-09-01
The development of a model for interstitial brachytherapy that uses high-activity, removable /sup 125/I sources in the RIF-1 murine flank tumor is reported. Experimental end points are clonogenic cell and tumor regrowth delay assays. For the clonogenic cell assay, interestitial radiation is delivered at total doses of 500-10,000 rad at dose rates of 0.9-2.7 rad/min to cells in annuli of tissue in the tumor. Dose-survival curves are characterized by an initial shoulder followed by a straight (exponential) portion, with D/sub 0/ similar to that of the curve obtained by external irradiation of the RIF-1 tumor in a self-contained cesium irradiatormore » at similar dose rates. Tumor regrowth curves have been obtained for minimum tumor doses of 500-5000 rad; marked tumor regression has been observed with minimum tumor doses as low as 2000 rad, but results are not as reproducible as the results obtained with the clonogenic cell assay.« less
A near infrared holographic glucose sensor.
Vezouviou, Evangelia; Lowe, Christopher R
2015-06-15
Real-time glucose monitoring has been beneficial in reducing health complications associated with diabetes as well as a decrease in mortality. This report describes a novel holographic platform, fabricated via laser ablation on chitosan hydrogel with gold nanoparticles with a replaying in visible and near IR. The sensor responded with a 12 nm and 7 nm shift in wavelength at glucose concentrations in the 0-70 mM range and in the visible and near IR, respectively, at pH 7.4 and an ionic strength of 154 mM. The sensor did not respond to potential interferences found in the interstitial fluid, such as fructose, vitamin C and lactate, at their respective normal concentrations and was stable to fluctuations in temperature, pH and ionic strength. The characteristics of this sensor suggests that it may be applicable for use as an implanted device for the real time monitoring of glucose concentrations in the interstitial fluid using near IR as the interrogating medium. Copyright © 2015 Elsevier B.V. All rights reserved.
Optical activity and defect/dopant evolution in ZnO implanted with Er
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azarov, Alexander; Galeckas, Augustinas; Kuznetsov, Andrej
2015-09-28
The effects of annealing on the optical properties and defect/dopant evolution in wurtzite (0001) ZnO single crystals implanted with Er ions are studied using a combination of Rutherford backscattering/channeling spectrometry and photoluminescence measurements. The results suggest a lattice recovery behavior dependent on ion dose and involving formation/evolution of an anomalous multipeak defect distribution, thermal stability of optically active Er complexes, and Er outdiffusion. An intermediate defect band occurring between the surface and ion-induced defects in the bulk is stable up to 900 °C and has a photoluminescence signature around 420 nm well corresponding to Zn interstitials. The optical activity of the Ermore » atoms reaches a maximum after annealing at 700 °C but is not directly associated to the ideal Zn site configuration, since the Er substitutional fraction is maximal already in the as-implanted state. In its turn, annealing at temperatures above 700 °C leads to dissociation of the optically active Er complexes with subsequent outdiffusion of Er accompanied by the efficient lattice recovery.« less
Curtin, Justin Paul; Wang, Minji
2017-08-01
Although the presence of titanium wear particles released into tissues is known to induce local inflammation following the therapeutic implantation of titanium devices into humans, the role that titanium ions play in adverse tissue responses has received little attention. Support that ongoing titanium ion release occurs is evidenced by the presence of ionic titanium bound to transferrin in blood, and ongoing excretion in the urine of patients with titanium devices. However, as reports documenting the presence of titanium within tissues do not distinguish between particulate and ionic forms due to technical challenges, the degree to which ionic titanium is released into tissues is unknown. To determine the potential for titanium ion release into tissues, this study evaluates available in vitro evidence relating to the release of ionic titanium under physiological conditions. This is a systematic literature review of studies reporting titanium ion release into solutions from titanium devices under conditions replicating the interstitial pH and constituents. Inclusion and exclusion criteria were defined. Of 452 articles identified, titanium ions were reported in nine media relevant to human biology in seventeen studies. Only one study, using human serum replicated both physiological pH and the concentration of constituents while reporting the presence of titanium ions. While there is insufficient information to explain the factors that contribute to the presence of titanium ions in serum of humans implanted with titanium devices, currently available information suggests that areas of future inquiry include the role of transferrin and organic acids.
El-Sayed, Adly H; Aly, A A; EI-Sayed, N I; Mekawy, M M; EI-Gendy, A A
2007-03-01
High quality heating device made of ferromagnetic alloy (thermal seed) was developed for hyperthermia treatment of cancer. The device generates sufficient heat at room temperature and stops heating at the Curie temperature T (c). The power dissipated from each seed was calculated from the area enclosed by the hysteresis loop. A new mathematical formula for the calculation of heating power was derived and showed good agreement with those calculated from hysteresis loop and calorimetric method.
First clinical evaluation of a new long-term subconjunctival glucose sensor.
Müller, Achim Josef; Knuth, Monika; Nikolaus, Katharina Sibylle; Herbrechtsmeier, Peter
2012-07-01
To evaluate the feasibility of an implantable subconjunctival glucose monitoring system (SGMS) for glucose monitoring in humans, we investigated the in vivo performance of the sensor in a clinical trial with five patients. The new SGMS consists of an implantable ocular mini implant (OMI) and a hand-held fluorescence photometer. The implantable subconjunctival glucose sensor is composed of a fluorescence resonance energy transfer system based on Concanavalin A chemistry, embedded in a nelfilcon polymer hydrogel disk. Blood glucose changes in humans were induced by oral glucose intake and insulin injections. The in vivo response of the new SGMS was tested in a first human clinical study with five diabetes patients. The OMI was well tolerated in the eyes of the patients. The SGMS exhibited high correlation coefficients (>0.88) with blood glucose changes and a good stability of the sensor response to glucose for the study period of 2 weeks. Lag times were in the range of 5-10 min. A total of 98% of all data pairs was in the clinical acceptable ranges A and B of the consensus error grid. For the first time, the possibility to measure glucose in vivo in the subconjunctival interstitial fluid for a period of 2 weeks was demonstrated in a human clinical trial. © 2012 Diabetes Technology Society.
Tselis, N; Maurer, U; Popp, W; Sack, H; Zamboglou, N
2014-04-01
The German Society of Radiation Oncology initiated a multicenter trial to evaluate core processes and subprocesses of radiotherapy by prospective evaluation of all important procedures in the most frequent malignancies treated by radiation therapy. The aim of this analysis was to assess the required resources for interstitial high-dose-rate (HDR) and low-dose-rate (LDR) prostate brachytherapy (BRT) based on actual time measurements regarding allocation of personnel and room occupation needed for specific procedures. Two radiotherapy centers (community hospital of Offenbach am Main and community hospital of Eschweiler) participated in this prospective study. Working time of the different occupational groups and room occupancies for the workflow of prostate BRT were recorded and methodically assessed during a 3-month period. For HDR and LDR BRT, a total of 560 and 92 measurements, respectively, were documented. The time needed for treatment preplanning was median 24 min for HDR (n = 112 measurements) and 6 min for LDR BRT (n = 21). Catheter implantation with intraoperative HDR real-time planning (n = 112), postimplantation HDR treatment planning (n = 112), and remotely controlled HDR afterloading irradiation (n = 112) required median 25, 39, and 50 min, respectively. For LDR real-time planning (n = 39) and LDR treatment postplanning (n = 32), the assessed median duration was 91 and 11 min, respectively. Room occupancy and overall mean medical staff times were 194 and 910 min respectively, for HDR, and 113 and 371 min, respectively, for LDR BRT. In this prospective analysis, the resource requirements for the application of HDR and LDR BRT of prostate cancer were assessed methodically and are presented for first time.
Probe for Sampling of Interstitial Fluid From Bone
NASA Technical Reports Server (NTRS)
Janle, Elsa M.
2004-01-01
An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.
Ash, Samuel Y; Harmouche, Rola; Ross, James C; Diaz, Alejandro A; Rahaghi, Farbod N; Sanchez-Ferrero, Gonzalo Vegas; Putman, Rachel K; Hunninghake, Gary M; Onieva, Jorge Onieva; Martinez, Fernando J; Choi, Augustine M; Bowler, Russell P; Lynch, David A; Hatabu, Hiroto; Bhatt, Surya P; Dransfield, Mark T; Wells, J Michael; Rosas, Ivan O; San Jose Estepar, Raul; Washko, George R
2018-06-05
Purpose To determine if interstitial features at chest CT enhance the effect of emphysema on clinical disease severity in smokers without clinical pulmonary fibrosis. Materials and Methods In this retrospective cohort study, an objective CT analysis tool was used to measure interstitial features (reticular changes, honeycombing, centrilobular nodules, linear scar, nodular changes, subpleural lines, and ground-glass opacities) and emphysema in 8266 participants in a study of chronic obstructive pulmonary disease (COPD) called COPDGene (recruited between October 2006 and January 2011). Additive differences in patients with emphysema with interstitial features and in those without interstitial features were analyzed by using t tests, multivariable linear regression, and Kaplan-Meier analysis. Multivariable linear and Cox regression were used to determine if interstitial features modified the effect of continuously measured emphysema on clinical measures of disease severity and mortality. Results Compared with individuals with emphysema alone, those with emphysema and interstitial features had a higher percentage predicted forced expiratory volume in 1 second (absolute difference, 6.4%; P < .001), a lower percentage predicted diffusing capacity of lung for carbon monoxide (DLCO) (absolute difference, 7.4%; P = .034), a 0.019 higher right ventricular-to-left ventricular (RVLV) volume ratio (P = .029), a 43.2-m shorter 6-minute walk distance (6MWD) (P < .001), a 5.9-point higher St George's Respiratory Questionnaire (SGRQ) score (P < .001), and 82% higher mortality (P < .001). In addition, interstitial features modified the effect of emphysema on percentage predicted DLCO, RVLV volume ratio, 6WMD, SGRQ score, and mortality (P for interaction < .05 for all). Conclusion In smokers, the combined presence of interstitial features and emphysema was associated with worse clinical disease severity and higher mortality than was emphysema alone. In addition, interstitial features enhanced the deleterious effects of emphysema on clinical disease severity and mortality. © RSNA, 2018 Online supplemental material is available for this article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalin, B.A.; Gladkov, V.P.; Volkov, N.V.
Penetration of alien atoms (Be, Ni) into Be, Al, Zr, Si and diamond was investigated under Ar{sup +} ion bombardment of samples having thermally evaporated films of 30--50 nm. Sputtering was carried out using a wide energy spectrum beam of Ar{sup +} ions of 9.4 keV to dose D = 1 {times} 10{sup 16}--10{sup 19} ion/cm{sup 2}. Implanted atom distribution in the targets was measured by Rutherford backscattering spectrometry (RBS) of H{sup +} and He{sup +} ions with energy of 1.6 MeV as well as secondary ion mass-spectrometry (SIMS). During the bombardment, the penetration depth of Ar atoms increases withmore » dose linearly. This depth is more than 3--20 times deeper than the projected range of bombarding ions and recoil atoms. This is a deep action effect. The analysis shows that the experimental data for foreign atoms penetration depth are similar to the data calculated for atom migration through the interstitial site in a field of internal (lateral) compressive stresses created in the near-surface layer of the substrate as a result of implantation. Under these experimental conditions atom ratio r{sub i}/r{sub m} (r{sub i} -- radius of dopant, r{sub m} -- radius target of substrate) can play a principal determining role.« less
Huang, Hai; Xu, Shaonian; Li, Fusheng; Du, Zhenguang; Wang, Liang
2016-04-27
To assess clinical application of computed tomography (CT)-guided (125)I seed implantation for patients who cannot endure or unwillingly receive repeated surgery, chemotherapy, or radiotherapy for unmanageable cervical lymph node metastases in head and neck cancer (HNC). Thirty-one consecutive patients received CT-guided (125)I seed implantation between February 2010 and December 2013. To evaluate the clinical efficiency, karnofsky performance score (KPS), numeric rating scale (NRS), and tumor volume at 3-, and 6-month post-implantation were compared with pre-implantation, along with local control rate (LCR), overall survival rate (OSR), and complications at 3, 6 months, 1, and 2 years. The tumor volume was obviously decreased at 3-, and 6-month post-implantation (21.23 ± 8.83 versus 9.19 ± 7.52 cm(2); 21.23 ± 8.83 versus 6.42 ± 9.79 cm(2); P < 0.05) compared with pre-implantation. The NRS was statistically reduced (3.06 ± 1.06 versus 7.77 ± 0.92; 2.39 ± 1.15 versus 7.77 ± 0.92; P < 0.05), while KPS was significantly improved (83.18 ± 5.97 versus 73.60 ± 7.90; 82.86 ± 5.43 versus 73.60 ± 7.90; P < 0.05) postoperatively at 3 and 6 months, respectively. The LCR at 3, 6 months, 1, and 2 years was 96.30, 83.87, 64.51, and 45.16%, respectively. The OSR was 100, 100, 67.74, and 45.16%, respectively. Three cases experienced grade I and two had grade II acute radiation toxicity. CT-guided seed implantation may be feasible and safe for HNC patients whose neck nodes are not manageable by routine strategies with fewer complications, higher LCR, and significant pain relief.
Kimball, F A; Frielink, R D; Porteus, S E
1978-01-01
Silicone rubber discs containing 15(S)-15-methyl prostaglandin F2 alpha ester (15-Me-PGF2 alpha) in the matrix were implanted in the left side of the scrotums of Sprague-Dawley rats. The effect of 1% and 2% drug concentration was examined for 10, 20, or 28 days and compared with the effects of Silastic discs containing no prostaglandin. The discs containing prostaglandin reduced mean testicular and accessory gland weights. Histologically the testes and epididymides showed decreased or absent spermatogenic elements and hypertrophy of the interstitial cell masses in comparison with other cells. Implanted prostaglandin significantly depressed serum testosterone, luteinizing hormone, and follicle-stimulating hormone (FSH) concentrations when 15-Me-PGF2 alpha plasma concentrations exceeded 2 ng/ml. Hormone concentrations returned to control values as drug concentrations declined. FSH concentrations significantly exceeded control values 10 and 20 days after implantation, when prostaglandin concentration was nondetectable. The acute suppression of all three hormones suggest that 15-Me-PGF2 alpha either may act directly on the tests to suppress testosterone production or may suppress testosterone production or may suppress gonadotropin secretion, resulting in depressed testosterone output.
Perez, Jessica; Diaz, Nancy; Tandon, Ishita; Plate, Rachel; Martindale, Christopher; Balachandran, Kartik
2018-06-01
While the valvulopathic effects of serotonin (5HT) and angiotensin-II (Ang-II) individually are known, it was not clear how 5HT and Ang-II might interact, specifically in the context of the mechanobiological responses due to altered valve mechanics potentiated by these molecules. In this context, the hypothesis of this study was that increased serotonin levels would result in accelerated progression toward disease in the presence of angiotensin-II-induced hypertension. C57/BL6 J mice were divided into four groups and subcutaneously implanted with osmotic pumps containing: PBS (control), 5HT (2.5 ng/kg/min), Ang-II (400 ng/kg/min), and 5HT + Ang-II (combination). Blood pressure was monitored using the tail cuff method. Echocardiography was performed on the mice before surgery and every week thereafter to assess ejection fraction. After three weeks, the mice were sacrificed and their hearts excised, embedded and sectioned for analysis of the aortic valves via histology and immunohistochemistry. In separate experiments, porcine valve interstitial cells (VICs) were directly stimulated with 5HT (10 -7 M), Ang-II (100 nM) or both and assayed for cellular contractility, cytoskeletal organization and collagen remodeling. After three weeks, average systolic blood pressure was significantly increased in the 5HT, Ang-II and combination groups compared to control. Echocardiographic analysis demonstrated significantly reduced ejection fraction in Ang-II and the combination groups. H&E staining demonstrated thicker leaflets in the combination groups, suggesting a more aggressive remodeling process. Picrosirius red staining and image analysis suggested that the Ang-II and combination groups had the largest proportion of thicker collagen fibers. VIC orientation, cellular contractility and collagen gene expression was highest for the 5HT + Ang-II combination treatment compared to all other groups. Overall, our results suggest that 5HT and Ang-II interact to result in significantly detrimental alteration of function and remodeling in the valve.
Dilute antimonide nitride for long wavelength infrared photodetection
NASA Astrophysics Data System (ADS)
Chen, X. Z.; Jin, Y. J.; Zhang, D. H.
2014-05-01
InSb1-xNx materials were fabricated by direct nitrogen implantation into InSb wafer and they are characterized by X-ray diffraction, Hall measurement, X-ray photoelectron spectroscopy. In-N bonds are clearly demonstrated and other forms of nitrogen, such as antisites (NIn), interstitial N2, also exist in the grown films. The ratio to the total nitrogen bonds formed in the materials varies with preparation conditions. The optical bandgap data confirmed bandgap narrowing due to the incorporation of nitrogen. Photoconductive and photovoltaic photodetectors are fabricated and the cut-off frequencies of up to 11.5 μm are demonstrated.
Effect of point defects on the amorphization of metallic alloys during ion implantation. [NiTi
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pedraza, D.F.; Mansur, L.K.
1985-01-01
A theoretical model of radiation-induced amorphization of ordered intermetallic compounds is developed. The mechanism is proposed to be the buildup of lattice defects to very high concentrations, which destabilizes the crystalline structure. Because simple point defects do not normally reach such levels during irradiation, a new defect complex containing a vacancy and an interstitial is hypothesized. Crucial properties of the complex are that the interstitial sees a local chemical environment similar to that of an atom in the ordered lattice, that the formation of the complex prevents mutual recombination and that the complex is immobile. The evolution of a disordermore » based on complexes is not accompanied by like point defect aggregation. The latter leads to the development of a sink microstructure in alloys that do not become amorphous. For electron irradiation, the complexes form by diffusional encounters. For ion irradiation, complexes are also formed directly in cascades. The possibility of direct amorphization in cascades is also included. Calculations for the compound NiTi show reasonable agreement with measured amorphization kinetics.« less
Baylor, Peter A; Sobenes, Juan R; Vallyathan, Val
2013-05-01
We present a case of interstitial pulmonary fibrosis accompanied by radiographic evidence of progressive massive fibrosis in a patient who had a 15-20 year history of almost daily recreational inhalation of methamphetamine. Mineralogical analysis confirmed the presence of talc on biopsy of the area of progressive massive fibrosis. The coexistence of interstitial pulmonary fibrosis and progressive massive fibrosis suggests that prolonged recreational inhalation of methamphetamine that has been "cut" with talc can result in sufficient amount of talc being inhaled to result in interstitial pulmonary fibrosis and progressive massive fibrosis in the absence of other causes.
LU, MINGJIAN; PU, DELI; ZHANG, WEIDONG; LIAO, JIANGRONG; ZHANG, TAO; YANG, GUANG; LIU, ZHENYIN; SINGH, SRISTI; GAO, FEI; ZHANG, FUJUN
2015-01-01
To evaluate the role of low-dose-rate interstitial brachytherapy using trans-bronchoscope 125I radioactive seeds implantation in patients with pulmonary atelectasis induced by lung cancer, in terms of feasibility, safety, quality of life (QOL), and survival time. Between April 2008 and June 2011, 15 patients from two medical institutions that had obstructive pulmonary atelectasis caused by inoperable lung cancer were assigned to receive 125I implantation endoluminal brachytherapy by bronchoscopy. Subsequent to the implantation of 125I seeds, the outcomes were measured in terms of procedure success rate, reopening of atelectasis, complications associated with the procedure, Karnofsky performance status (KPS) scores and survival time. The surgical procedure was successfully performed in all 15 patients. No procedure-associated mortality occurred and the complications were mild and considered acceptable. Irritable cough and temporary increase of hemoptysis occurred in 11 (73.3%) and 10 (66.7%) patients respectively, and were the most common complications. The pulmonary atelectasis reopening rate subsequent to the procedure was 86.7, 76.9, 80.0, 75.0 and 50.0% at 2, 6, 12, 18 and 24 months, respectively. The KPS score significantly improved following the implantation of 125I seeds and the duration of improvement ranged between 3 and 27 months. The median and mean survival times were 15.6 and 16 months, respectively. Actuarial survival rates at 6, 12 and 24 months after the procedure were 86.7, 66.7 and 13.3%, respectively. In patients with advanced lung cancer and those presenting with obstructive pulmonary atelectasis, treatment with intraluminal implantation of 125I seeds is a safe and effective therapy option with easy accessibility. PMID:26171002
Lu, Mingjian; Pu, Deli; Zhang, Weidong; Liao, Jiangrong; Zhang, Tao; Yang, Guang; Liu, Zhenyin; Singh, Sristi; Gao, Fei; Zhang, Fujun
2015-07-01
To evaluate the role of low-dose-rate interstitial brachytherapy using trans-bronchoscope 125 I radioactive seeds implantation in patients with pulmonary atelectasis induced by lung cancer, in terms of feasibility, safety, quality of life (QOL), and survival time. Between April 2008 and June 2011, 15 patients from two medical institutions that had obstructive pulmonary atelectasis caused by inoperable lung cancer were assigned to receive 125 I implantation endoluminal brachytherapy by bronchoscopy. Subsequent to the implantation of 125 I seeds, the outcomes were measured in terms of procedure success rate, reopening of atelectasis, complications associated with the procedure, Karnofsky performance status (KPS) scores and survival time. The surgical procedure was successfully performed in all 15 patients. No procedure-associated mortality occurred and the complications were mild and considered acceptable. Irritable cough and temporary increase of hemoptysis occurred in 11 (73.3%) and 10 (66.7%) patients respectively, and were the most common complications. The pulmonary atelectasis reopening rate subsequent to the procedure was 86.7, 76.9, 80.0, 75.0 and 50.0% at 2, 6, 12, 18 and 24 months, respectively. The KPS score significantly improved following the implantation of 125 I seeds and the duration of improvement ranged between 3 and 27 months. The median and mean survival times were 15.6 and 16 months, respectively. Actuarial survival rates at 6, 12 and 24 months after the procedure were 86.7, 66.7 and 13.3%, respectively. In patients with advanced lung cancer and those presenting with obstructive pulmonary atelectasis, treatment with intraluminal implantation of 125 I seeds is a safe and effective therapy option with easy accessibility.
Paiva, M B; Saxton, R E; Letts, G A; Chung, P S; Soudant, J; Vanderwerf, Q; Castro, D J
1995-10-01
Photodynamic therapy (PDT) with lasers and new dyes has gained popularity in recent years as a minimally invasive technique with high tumoricidal effects in vitro and in some cancer patients. However, because new laser dyes are not FDA approved at present, the clinical evaluation of PDT may be years away. During the past 6 years we have used laser alone for photothermal ablation in both preclinical studies and in a large number of patients with an observed 60% tumor response rate. The 40% treatment failure led us to explore the possibility of combined therapy with lasers and standard chemotherapeutic drugs. We have recently tested a promising preclinical alternative using implantation of a bare 600-microns KTP 532 laser fiberoptic in multiple tumor sites 30 min after intratumor injection of the anthrapyrazole DUP-941. As a control, this drug was injected in 3 sites of P3 human squamous cell tumor transplants in nude mice, which led to tumor stasis without regression. Similar 400-600 mm3 tumors exposed to laser illumination alone (0.8 W for 5 sec) at multiple sites resulted in tumor regrowth after 10 weeks in 80% of the animals. However, combining interstitial laser illumination with intratumor DUP-941 injections led to complete tumor regression in 85% of the mice. We propose that intratumor drug injection followed by interstitial laser fiberoptic treatment represents a potentially useful new method for tumor ablation in advanced cancer patients.
The Objective Identification and Quantification of Interstitial Lung Abnormalities in Smokers.
Ash, Samuel Y; Harmouche, Rola; Ross, James C; Diaz, Alejandro A; Hunninghake, Gary M; Putman, Rachel K; Onieva, Jorge; Martinez, Fernando J; Choi, Augustine M; Lynch, David A; Hatabu, Hiroto; Rosas, Ivan O; Estepar, Raul San Jose; Washko, George R
2017-08-01
Previous investigation suggests that visually detected interstitial changes in the lung parenchyma of smokers are highly clinically relevant and predict outcomes, including death. Visual subjective analysis to detect these changes is time-consuming, insensitive to subtle changes, and requires training to enhance reproducibility. Objective detection of such changes could provide a method of disease identification without these limitations. The goal of this study was to develop and test a fully automated image processing tool to objectively identify radiographic features associated with interstitial abnormalities in the computed tomography scans of a large cohort of smokers. An automated tool that uses local histogram analysis combined with distance from the pleural surface was used to detect radiographic features consistent with interstitial lung abnormalities in computed tomography scans from 2257 individuals from the Genetic Epidemiology of COPD study, a longitudinal observational study of smokers. The sensitivity and specificity of this tool was determined based on its ability to detect the visually identified presence of these abnormalities. The tool had a sensitivity of 87.8% and a specificity of 57.5% for the detection of interstitial lung abnormalities, with a c-statistic of 0.82, and was 100% sensitive and 56.7% specific for the detection of the visual subtype of interstitial abnormalities called fibrotic parenchymal abnormalities, with a c-statistic of 0.89. In smokers, a fully automated image processing tool is able to identify those individuals who have interstitial lung abnormalities with moderate sensitivity and specificity. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Xiao, Haibo; Xu, Linfang; Wang, Ruilong; Yang, Changping
2017-09-01
The geometric structure, electronic structure and formation energy of CaCu3Ti4O12 (CCTO) with interstitial copper atom have been studied using the density-functional method within the GGA approximation. Result of structural optimization shows that the interstitial Cu-atom (Cu7) prefers to occupy a special location which is symmetrical with an intrinsic copper atom (Cu13) deviated from the normal site. The mulliken analysis indicates the loss of electrons from interstitial atom (Cu7) and Cu13 are only half more of the losing in other copper atom, which reveals a characteristics of covalent bonding between Cu7/Cu13 and surrounding oxygen atoms respectively. Meanwhile, it is found from electron density difference (EDD) and orbital analysis that the introduction of interstitial Cu atom causes prominent structural reconstruction of a new ;CuO4; quadrilateral. Moreover, the new ;CuO4; planar leads to a corresponding electronic reconstruction in the hybridization between Cu7/Cu13 3d and O 2p at the vicinity of fermi surface, for which a new conductive filament channel comes into being. Besides, the formation energies of the interstitial defects in various charge states are corrected with the value of 2.18, -4.17 and -9.46 eV for charge of 0, 1+ and 2+, respectively.
Older, R A; Synder, B; Krupski, T L; Glembocki, D J; Gillenwater, J Y
2001-05-01
In several of the initial patients undergoing brachytherapy at our institution radioactive implants were visible in the thorax on chest radiography. The clinical ramifications of this unanticipated finding were unclear. Thus, we investigated the incidence of brachytherapy seed migration to the chest and whether these seeds were associated with any clinical significance. We retrospectively reviewed the records of all patients who underwent ultrasound or computerized tomography guided brachytherapy of 103palladium seeds from March 1997 to March 1999. This list of patients on brachytherapy was then matched against the radiology computer system to determine those who had undergone chest X-ray after brachytherapy. When the radiology report was unclear regarding brachytherapy seeds, chest x-rays were reviewed by one of us (R. O.) to determine the presence and position of the seeds. Post-brachytherapy chest x-rays were available in 110 of the 183 patients. In 78 cases no brachytherapy seeds were identified. Radioactive implants were identified on chest radiography in 32 patients (29%), including 1 to 5 seeds in 20, 8, 1, 2 and 1, respectively. No patients complained of any change in pulmonary symptoms after brachytherapy. Radioactive implants migrated after brachytherapy for localized prostate cancer in 29% of the patients who underwent post-procedure radiography. There did not appear to be a pattern to the seed distribution. However, while the incidence was not negligible, no patient appeared to have any acute pulmonary symptoms. Therefore, while the migration of radioactive implants to the chest is a real phenomenon, it appears to have no adverse clinical consequences in the early post-procedure period.
NASA Astrophysics Data System (ADS)
Murkute, Punam; Ghadi, Hemant; Saha, Shantanu; Chavan, Vinayak; Chakrabarti, Subhananda
2018-03-01
High band gap (3.34 eV) and large exciton binding energy (60 meV) at room temperature facilitates ZnO as a useful candidate for optoelectronics devices. Presence of zinc interstitial and oxygen vacancies results in n-type ZnO film. Phosphorus implantation was carried out using plasma immersion ion implantation technique (2kV, 900W) for constant duration (50 s) on RF sputtered ZnO thin films (Sample A). For dopant activation, sample A was subjected to Rapid Thermal Annealing (RTA) at 700, 800, 900 and 1000°C for 10 s in Oxygen ambient (Sample B, C, D, E). Low temperature (18 K) photoluminescence measurement demonstrated strong donor bound exciton peak for sample A. Dominant donor to acceptor pair peak (DAP) was observed for sample D at around 3.22 eV with linewidth of 131.3 meV. High resolution x-ray diffraction measurement demonstrated (001) and (002) peaks for sample A. (002) peak with high intensity was observed from all annealed samples. Incorporation of phosphorus in ZnO films leads to peak shift towards higher 2θ angle indicate tensile strain in implanted samples. Scanning electron microscopy images reveals improvement in grain size distribution along with reduction of implantation related defects. Raman spectra measured A1(LO) peak at around 576 cm-1 for sample A. Low intensity E2 (high) peak was observed for sample D indicating formation of (PZn+2VZn) complexes. From room temperature Hall measurement, sample D measured 1.17 x 1018 cm -3 carrier concentration with low resistivity of 0.464 Ω.
Yamakawa, Hideaki; Hagiwara, Eri; Kitamura, Hideya; Yamanaka, Yumie; Ikeda, Satoshi; Sekine, Akimasa; Baba, Tomohisa; Iso, Shinichiro; Okudela, Koji; Iwasawa, Tae; Takemura, Tamiko; Kuwano, Kazuyoshi; Ogura, Takashi
2016-01-01
Background Patients with idiopathic interstitial pneumonias sometimes have a few features of connective tissue disease (CTD) and yet do not fulfil the diagnostic criteria for any specific CTD. Objective This study was conducted to elucidate the characteristics, prognosis, and disease behavior in patients with interstitial lung disease (ILD) associated with systemic sclerosis (SSc)-related autoantibodies. Methods We retrospectively analyzed medical records of 72 ILD patients: 40 patients with SSc (SSc-ILD) and 32 patients with SSc-related autoantibody-positive ILD but not with CTD (ScAb-ILD), indicating lung-dominant CTD with SSc-related autoantibody. Results Patients with SSc-ILD were predominantly females and non-smokers, and most had nonspecific interstitial pneumonia confirmed by high-resolution computed tomography (HRCT) and pathological analysis. However, about half of the patients with ScAb-ILD were male and current or ex-smokers. On HRCT analysis, honeycombing was more predominant in patients with ScAb-ILD than with SSc-ILD. Pathological analysis showed the severity of vascular intimal or medial thickening in the SSc-ILD patients to be significantly higher than that in the ScAb-ILD patients. Survival curves showed that the patients with ScAb-ILD had a significantly poorer outcome than those with SSc-ILD. Conclusion Data from this study suggest that lung-dominant CTD with SSc-related autoantibody is a different disease entity from SSc-ILD. PMID:27564852
Yoshida, Ken; Yamazaki, Hideya; Kotsuma, Tadayuki; Akiyama, Hironori; Takenaka, Tadashi; Masui, Koji; Yoshioka, Yasuo; Uesugi, Yasuo; Shimbo, Taiju; Yoshikawa, Nobuhiko; Yoshioka, Hiroto; Arika, Takumi; Tanaka, Eiichi; Narumi, Yoshifumi
2017-02-01
We report our study on two patients to highlight the risk of underdosage of the clinical target volume (CTV) due to edema during high-dose-rate interstitial brachytherapy (HDR-ISBT) of mobile tongue cancer. To treat the lateral side of the CTV, flexible applicator tubes were implanted on the mouth floor. Two-dimensional planning was performed using X-ray images for Case 1, and three-dimensional (3D) planning was performed using computed tomography (CT) for Case 2. Prescribed doses for both cases were 54 Gy in nine fractions. Case 1 was treated for cancer of the right lateral border of the tongue in 2005. Tongue edema occurred after implantation, and part of the lateral border of the tongue protruded between the applicator tubes. Acute mucosal reaction abated in the protruded area earlier than in the other parts of the CTV. In this case, the tumor recurred in this area 5 months after the treatment. Case 2 was treated for cancer of the left lateral border of the tongue. Because tongue edema occurred in this case also, plastic splints were inserted between the applicator tubes to push the edematous region into the irradiated area. The mucosal surface of the CTV was covered by the 70% isodose, and 100% isodose line for before and after splint insertion. Local control of the tumor was achieved 4 years after treatment. To ensure sufficient target coverage, 3D image-based planning using CT should be performed, followed by re-planning using repeated CT as needed. Also, the development of devices to prevent protrusion of the edematous tissue outside the target area will help to ensure the full dosing of CTV.
Prostate thermal therapy with catheter-based ultrasound devices and MR thermal monitoring
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Nau, Will H.; Kinsey, Adam; Ross, Tony; Wootton, Jeff; Juang, Titania; Butts-Pauly, Kim; Ricke, Viola; Liu, Erin H.; Chen, Jing; Bouley, Donna M.; Van den Bosch, Maurice; Sommer, Graham
2007-02-01
Four types of transurethral applicators were devised for thermal ablation of prostate combined with MR thermal monitoring: sectored tubular transducer devices with directional heating patterns; planar and curvilinear devices with narrow heating patterns; and multi-sectored tubular devices capable of dynamic angular control without applicator movement. These devices are integrated with a 4 mm delivery catheter, incorporate an inflatable cooling balloon (10 mm OD) for positioning within the prostate and capable of rotation via an MR-compatible motor. Interstitial devices (2.4 mm OD) have been developed for percutaneous implantation with directional or dynamic angular control. In vivo experiments in canine prostate under MR temperature imaging were used to evaluate the heating technology and develop treatment control strategies. MR thermal imaging in a 0.5 T interventional MRI was used to monitor temperature and thermal dose in multiple slices through the target volume. Sectored tubular, planar, and curvilinear transurethral devices produce directional coagulation zones, extending 15-20 mm radial distance to the outer prostate capsule. Sequential rotation and modulated dwell time can conform thermal ablation to selected regions. Multi-sectored transurethral applicators can dynamically control the angular heating profile and target large regions of the gland in short treatment times without applicator manipulation. Interstitial implants with directional devices can be used to effectively ablate the posterior peripheral zone of the gland while protecting the rectum. The MR derived 52 °C and lethal thermal dose contours (t 43=240 min) allowed for real-time control of the applicators and effectively defined the extent of thermal damage. Catheter-based ultrasound devices, combined with MR thermal monitoring, can produce relatively fast and precise thermal ablation of prostate, with potential for treatment of cancer or BPH.
Modification of molybdenum surface by low-energy oxygen implantation at room temperature
NASA Astrophysics Data System (ADS)
Kavre Piltaver, Ivna; Jelovica Badovinac, Ivana; Peter, Robert; Saric, Iva; Petravic, Mladen
2017-12-01
We have studied the initial stages of oxide formation on molybdenum surfaces under 1 keV O2+ ion bombardment at room temperature (RT), using x-ray photoelectron spectroscopy around Mo 3d or O 1s core-levels and the valence band photoemission. The results are compared with the oxidation mechanism of thermally oxidized Mo at RT. The thermal oxidation reveals the formation of a very thin MoO2 layer that prevents any further adsorption of oxygen at higher oxygen doses. Oxygen implantation is more efficient in creating thicker oxide films with the simultaneous formation of several oxide compounds. The oxidation rates of MoO2 and Mo2O5 follow the parabolic growth rate consistent with the mass transport driven by diffusion of either neutral or singly and doubly charged oxygen interstitials. The oxidation of MoO3, which occurs at a later oxidation stage, follows the logarithmic rate driven by the diffusion of cations in an electric field.
Perez-Calatayud, Jose; Richart, Jose; Guirado, Damián; Pérez-García, Jordi; Rodríguez, Silvia; Santos, Manuel
2012-01-01
Purpose SeedSelectron® v1.26b (Nucletron BV, The Netherlands) is an afterloader system used in prostate interstitial permanent brachytherapy with I-125 selectSeed seeds. It contains a diode array to assay all implanted seeds. Only one or two seeds can be extracted during the surgical procedure and assayed using a well chamber to check the manufacturer air-kerma strength (SK) and to calibrate the diode array. Therefore, it is not feasible to assay 5–10% seeds as required by the AAPM-ESTRO. In this study, we present a practical solution of the SeedSelectron® users to fulfill the AAPM- ESTRO recommendations. Material and methods The method is based on: a) the SourceCheck® well ionization chamber (PTW, Germany) provided with a PTW insert; b) n = 10 selectSeed from the same batch and class as the seeds for the implant; c) the Nucletron insert to accommodate the n = 10 seeds on the SourceCheck® and to measure their averaged SK. Results for 56 implants have been studied comparing the SK value from the manufacturer with the one obtained with the n = 10 seeds using the Nucletron insert prior to the implant and with the SK of just one seed measured with the PTW insert during the implant. Results We are faced with SK deviation for individual seeds up to 7.8%. However, in the majority of cases SK is in agreement with the manufacturer value. With the method proposed using the Nucletron insert, the large deviations of SK are reduced and for 56 implants studied no deviation outside the range of the class were found. Conclusions The new Nucletron insert and the proposed procedure allow to evaluate the SK of the n = 10 seeds prior to the implant, fulfilling the AAPM-ESTRO recommendations. It has been adopted by Nucletron to be extended to seedSelectron® users under request. PMID:23346136
Zelefsky, Michael J; Cohen, Gilad N; Taggar, Amandeep S; Kollmeier, Marisa; McBride, Sean; Mageras, Gig; Zaider, Marco
Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program. Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage. The implanted seed positions were automatically segmented from the cone-beam images, fused onto a new set of acquired ultrasound images, reimported into the planning system, and recontoured. Dose distributions were recalculated based upon actual implanted seed coordinates and recontoured ultrasound images and were reviewed. If any dose deficiencies within the prostate target were identified, additional needles and seeds were added. Once an implant was deemed acceptable, the procedure was completed, and anesthesia was reversed. When the intraoperative ultrasound-based quality assurance assessment was performed after seed placement, the median volume receiving 100% of the dose (V100) was 93% (range, 74% to 98%). Before seed correction, 23% (6/26) of cases were noted to have V100 <90%. Based on this intraoperative assessment and replanning, additional seeds were placed into dose-deficient regions within the target to improve target dose distributions. Postcorrection, the median V100 was 97% (range, 93% to 99%). Following intraoperative dose corrections, all implants achieved V100 >90%. In these patients, postimplantation evaluation during the actual prostate seed implant procedure was successfully applied to determine the need for additional seeds to correct dose deficiencies before anesthesia reversal. When applied, this approach should significantly reduce intraoperative errors and chances for suboptimal dose delivery during prostate brachytherapy. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
2012-01-01
Background The capacity for herpesvirus to cause disease in cetaceans is unclear and may be varied depending on the different conditions of individuals and between different species. Kidney pathology and intralesional virus-associated infection have been rarely reported in cetaceans. Result On April 2004, an old adult male Blainville’s beaked whale (Mesoplodon densirostris) 420 cm long with a poor body condition was stranded on Tenerife Island. During necropsy, no gross lesions were observed in the kidneys. However, membranous glomerulonephritis, multifocal interstitial lymphoplasmacytic nephritis and acute multifocal necrotizing tubulointerstitial nephritis with intranuclear inclusion bodies was diagnosed by histological analysis. Tissue samples were submitted for bacteriological analysis and molecular viral screening. Conclusion A novel alpha herpesvirus associated with interstitial nephritis was identified in an old adult male Blainville's beaked whale (M. densirostris) with a poor body condition stranded in the Canary Islands. This report suggests that identification of herpesvirus infection could be used as a differential diagnosis for interstitial nephritis in cetaceans. PMID:23237059
Effects of interstitial heating on the RIF-1 tumor using an Nd:YAG laser with multiple fibers.
Tobin, K M; Waldow, S M
1996-01-01
Hyperthermia was induced in tumor-bearing C3H mice using a Nd:YAG laser emitting near-infrared radiation at 1,064 nm. The efficacy of multiple implanted fiberoptics in the control of the RIF-1 tumor was investigated. RIF-1 tumors in the right hind leg were heated interstitially at 42, 44, or 46 degrees C for 30 or 60 minutes. Two, three, or four 400-microns quartz fibers terminating in a 1.0-cm cylindrical diffusor were inserted into each tumor, as were five microthermocouples to monitor temperature during treatment. Laser Doppler Flow (LDF) was also recorded pre- and post-treatment to determine changes in red blood cell flux in overlying skin (42, 44, or 46 degrees C) and the center of the tumor (46 degrees C). These experiments indicated that interstitial heating at 42, 44, and 46 degrees C resulted in tumor growth delay, although long-term control of tumors was not achieved. Treatment using four fibers resulted in the greatest tumor growth delay at 42 and 44 degrees C, increasing tumor doubling time by 50% or greater compared to control tumors; tumor growth delay following 46 degrees C treatments was seven times greater than that in control tumors. Significant changes (decreases) in LDF (P < .05) were seen in four treatment groups, using two fibers at 42 degrees C for 30 minutes, four fibers at 44 and 46 degrees C for 60 minutes on the overlying skin, and 46 degrees C for 60 minutes in the center of the tumor. Initial data indicate that interstitial heating with multiple fibers increases tumor growth delay compared to previous single fiber treatments, with tumor growth delay increasing with increasing treatment temperature; however, long-term tumor control was not achieved under the conditions investigated. Follow-up studies will explore the use of higher temperatures and/or longer treatment times in order to optimize tumor response.
Dilute antimonide nitride for long wavelength infrared photodetection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, X. Z.; Jin, Y. J.; Zhang, D. H.
2014-05-15
InSb{sub 1−x}N{sub x} materials were fabricated by direct nitrogen implantation into InSb wafer and they are characterized by X-ray diffraction, Hall measurement, X-ray photoelectron spectroscopy. In-N bonds are clearly demonstrated and other forms of nitrogen, such as antisites (N{sub In}), interstitial N{sub 2}, also exist in the grown films. The ratio to the total nitrogen bonds formed in the materials varies with preparation conditions. The optical bandgap data confirmed bandgap narrowing due to the incorporation of nitrogen. Photoconductive and photovoltaic photodetectors are fabricated and the cut-off frequencies of up to 11.5 μm are demonstrated.
Orthopaedic Implant Design and Manufacturing for Traumatic Injuries
2012-03-31
Body ………………………………………………………………………………….. 1 Key Research Accomplishments………………………………………….…….. 91 Reportable Outcomes...against the woven materials was severe, we investigated collagen crosslinking as a technique to improve the wear resistance of cartilage. BODY Below...mixture of solid matrix and interstitial fluid; as opposed to potentially including a third phase of air if the sample dried out during the test. The
Crackle analysis for chest auscultation and comparison with high-resolution CT findings.
Kawamura, Takeo; Matsumoto, Tsuneo; Tanaka, Nobuyuki; Kido, Shoji; Jiang, Zhongwei; Matsunaga, Naofumi
2003-01-01
The purpose of our study was to clarify the correlation between respiratory sounds and the high-resolution CT (HRCT) findings of lung diseases. Respiratory sounds were recorded using a stethoscope in 41 patients with crackles. All had undergone inspiratory and expiratory CT. Subjects included 18 patients with interstitial pneumonia and 23 without interstitial pneumonia. Two parameters, two-cycle duration (2CD) and initial deflection width (IDW) of the "crackle," were induced by time-expanded waveform analysis. Two radiologists independently assessed 11 HRCT findings. An evaluation was carried out to determine whether there was a significant difference in the two parameters between the presence and absence of each HRCT finding. The two parameters of crackles were significantly shorter in the interstitial pneumonia group than the non-interstitial pneumonia group. Ground-glass opacity, honeycombing, lung volume reduction, traction bronchiectasis, centrilobular nodules, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were correlated with one or two parameters in all patients, whereas the other three findings were not. Among the interstitial pneumonia group, traction bronchiectasis, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were significantly correlated with one or two parameters. Abnormal respiratory sounds were correlated with some HRCT findings.
A first-principles and experimental study of helium diffusion in periclase MgO
NASA Astrophysics Data System (ADS)
Song, Zhewen; Wu, Henry; Shu, Shipeng; Krawczynski, Mike; Van Orman, James; Cherniak, Daniele J.; Bruce Watson, E.; Mukhopadhyay, Sujoy; Morgan, Dane
2018-02-01
The distribution of He isotopes is used to trace heterogeneities in the Earth's mantle, and is particularly useful for constraining the length scale of heterogeneity due to the generally rapid diffusivity of helium. However, such an analysis is challenging because He diffusivities are largely unknown in lower mantle phases, which can influence the He profiles in regions that cycle through the lower mantle. With this motivation, we have used first-principles simulations based on density functional theory to study He diffusion in MgO, an important lower mantle phase. We first studied the case of interstitial helium diffusion in perfect MgO and found a migration barrier of 0.73 eV at zero pressure. Then we used the kinetic Monte Carlo method to study the case of substitutional He diffusion in MgO, where we assumed that He diffuses on the cation sublattice through cation vacancies. We also performed experiments on He diffusion at atmospheric pressure using ion implantation and nuclear reaction analysis in both as-received and Ga-doped samples. A comparison between the experimental and simulation results are shown. This work provides a foundation for further studies at high-pressure.
Ling, Wei; Liew, Guoguang; Li, Ya; Hao, Yafeng; Pan, Huizhuo; Wang, Hanjie; Ning, Baoan; Xu, Hang; Huang, Xian
2018-06-01
The combination of novel materials with flexible electronic technology may yield new concepts of flexible electronic devices that effectively detect various biological chemicals to facilitate understanding of biological processes and conduct health monitoring. This paper demonstrates single- or multichannel implantable flexible sensors that are surface modified with conductive metal-organic frameworks (MOFs) such as copper-MOF and cobalt-MOF with large surface area, high porosity, and tunable catalysis capability. The sensors can monitor important nutriments such as ascorbicacid, glycine, l-tryptophan (l-Trp), and glucose with detection resolutions of 14.97, 0.71, 4.14, and 54.60 × 10 -6 m, respectively. In addition, they offer sensing capability even under extreme deformation and complex surrounding environment with continuous monitoring capability for 20 d due to minimized use of biological active chemicals. Experiments using live cells and animals indicate that the MOF-modified sensors are biologically safe to cells, and can detect l-Trp in blood and interstitial fluid. This work represents the first effort in integrating MOFs with flexible sensors to achieve highly specific and sensitive implantable electrochemical detection and may inspire appearance of more flexible electronic devices with enhanced capability in sensing, energy storage, and catalysis using various properties of MOFs. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Threshold irradiation dose for amorphization of silicon carbide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snead, L.L.; Zinkle, S.J.
1997-04-01
The amorphization of silicon carbide due to ion and electron irradiation is reviewed with emphasis on the temperature-dependent critical dose for amorphization. The effect of ion mass and energy on the threshold dose for amorphization is summarized, showing only a weak dependence near room temperature. Results are presented for 0.56 MeV silicon ions implanted into single crystal 6H-SiC as a function of temperature and ion dose. From this, the critical dose for amorphization is found as a function of temperature at depths well separated from the implanted ion region. Results are compared with published data generated using electrons and xenonmore » ions as the irradiating species. High resolution TEM analysis is presented for the Si ion series showing the evolution of elongated amorphous islands oriented such that their major axis is parallel to the free surface. This suggests that surface of strain effects may be influencing the apparent amorphization threshold. Finally, a model for the temperature threshold for amorphization is described using the Si ion irradiation flux and the fitted interstitial migration energy which was found to be {approximately}0.56 eV. This model successfully explains the difference in the temperature-dependent amorphization behavior of SiC irradiated with 0.56 MeV silicon ions at 1 x 10{sup {minus}3} dpa/s and with fission neutrons irradiated at 1 x 10{sup {minus}6} dpa/s irradiated to 15 dpa in the temperature range of {approximately}340 {+-} 10K.« less
Vanadium supersaturated silicon system: a theoretical and experimental approach
NASA Astrophysics Data System (ADS)
Garcia-Hemme, Eric; García, Gregorio; Palacios, Pablo; Montero, Daniel; García-Hernansanz, Rodrigo; Gonzalez-Diaz, Germán; Wahnon, Perla
2017-12-01
The effect of high dose vanadium ion implantation and pulsed laser annealing on the crystal structure and sub-bandgap optical absorption features of V-supersaturated silicon samples has been studied through the combination of experimental and theoretical approaches. Interest in V-supersaturated Si focusses on its potential as a material having a new band within the Si bandgap. Rutherford backscattering spectrometry measurements and formation energies computed through quantum calculations provide evidence that V atoms are mainly located at interstitial positions. The response of sub-bandgap spectral photoconductance is extended far into the infrared region of the spectrum. Theoretical simulations (based on density functional theory and many-body perturbation in GW approximation) bring to light that, in addition to V atoms at interstitial positions, Si defects should also be taken into account in explaining the experimental profile of the spectral photoconductance. The combination of experimental and theoretical methods provides evidence that the improved spectral photoconductance up to 6.2 µm (0.2 eV) is due to new sub-bandgap transitions, for which the new band due to V atoms within the Si bandgap plays an essential role. This enables the use of V-supersaturated silicon in the third generation of photovoltaic devices.
NASA Astrophysics Data System (ADS)
Gao, Chan; Tian, Dongfeng; Li, Maosheng; Qian, Dazhi
2018-03-01
In fusion applications, helium, implanted or created by transmutation, plays an important role in the response of reduced-activation ferritic/martensitic steels to neutron radiation damage. The effects of helium concentration and radiation temperature on interaction of interstitial helium atoms with displacement cascades have been studied in Fe-He system using molecular dynamics with recently developed Fe-He potential. Results indicate that interstitial helium atoms produce no additional defects at peak time and promote recombination of Frenkel pairs at lower helium concentrations, but suppress recombination of Frenkel pairs at larger helium concentrations. Moreover, large helium concentrations promote the production of defects at the end of cascades. The number of substitutional helium atoms increases with helium concentration at peak time and the end of cascades, but the number of substitutional helium atoms at peak time is smaller than that at the end of displacement cascades. High radiation temperatures promote the production at peak time and the recombination of defects at the end of cascades. The number of substitutional helium atoms increases with radiation temperature, but that at peak time is smaller than that at the end of cascades.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Ying; Field, Kevin G.; Allen, Todd R.
2016-02-23
A detailed analysis of the diffusion fluxes near and at grain boundaries of irradiated Fe–Cr–Ni alloys, induced by preferential atom-vacancy and atom-interstitial coupling, is presented. The diffusion flux equations were based on the Perks model formulated through the linear theory of the thermodynamics of irreversible processes. The preferential atom-vacancy coupling was described by the mobility model, whereas the preferential atom-interstitial coupling was described by the interstitial binding model. The composition dependence of the thermodynamic factor was modeled using the CALPHAD approach. The calculated fluxes up to 10 dpa suggested the dominant diffusion mechanism for chromium and iron is via vacancy,more » while that for nickel can swing from the vacancy to the interstitial dominant mechanism. The diffusion flux in the vicinity of a grain boundary was found to be greatly modified by the segregation induced by irradiation, leading to the oscillatory behavior of alloy compositions in this region.« less
One dimensional motion of interstitial clusters and void growth in Ni and Ni alloys
NASA Astrophysics Data System (ADS)
Yoshiie, T.; Ishizaki, T.; Xu, Q.; Satoh, Y.; Kiritani, M.
2002-12-01
One dimensional (1-D) motion of interstitial clusters is important for the microstructural evolution in metals. In this paper, the effect of 2 at.% alloying with elements Si (volume size factor to Ni: -5.81%), Cu (7.18%), Ge (14.76%) and Sn (74.08%) in Ni on 1-D motion of interstitial clusters and void growth was studied. In neutron irradiated pure Ni, Ni-Cu and Ni-Ge, well developed dislocation networks and voids in the matrix, and no defects near grain boundaries were observed at 573 K to a dose of 0.4 dpa by transmission electron microscopy. No voids were formed and only interstitial type dislocation loops were observed near grain boundaries in Ni-Si and Ni-Sn. The reaction kinetics analysis which included the point defect flow into planar sink revealed the existence of 1-D motion of interstitial clusters in Ni, Ni-Cu and Ni-Ge, and lack of such motion in Ni-Si and Ni-Sn. In Ni-Sn and Ni-Si, the alloying elements will trap interstitial clusters and thereby reduce the cluster mobility, which lead to the reduction in void growth.
1998-06-29
of some interstitial water during intercalation of the disulfide polymer of DMcT. Elemental analysis gives a composition for the intercalation...the disulfide polymer of DMcT. Elemental analysis gives a composition for the intercalation material of [(polyDMcT)o25*V205.4H20]. The cyclic...13.5 A). This change is consistent with loss of some interstitial water during intercalation of the disulfide polymer of DMcT. Elemental analysis
On the Potential of Bulk Metallic Glasses for Dental Implantology: Case Study on Ti40Zr10Cu36Pd14.
Liens, Alethea; Etiemble, Aurélien; Rivory, Pascaline; Balvay, Sandra; Pelletier, Jean-Marc; Cardinal, Sandrine; Fabrègue, Damien; Kato, Hidemi; Steyer, Philippe; Munhoz, Tais; Adrien, Jerome; Courtois, Nicolas; Hartmann, Daniel J; Chevalier, Jérôme
2018-02-06
Ti 40 Zr 10 Cu 36 Pd 14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies' prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 °C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.√m. Moreover, the alloy shows a relatively lower Young's modulus (96 GPa) than the Ti-6Al-4V alloy (110-115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of -0.07 V/SCE and corrosion current density of 6.0 nA/cm²), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.
On the Potential of Bulk Metallic Glasses for Dental Implantology: Case Study on Ti40Zr10Cu36Pd14
Liens, Alethea; Etiemble, Aurélien; Rivory, Pascaline; Balvay, Sandra; Pelletier, Jean-Marc; Cardinal, Sandrine; Fabrègue, Damien; Kato, Hidemi; Munhoz, Tais; Adrien, Jerome; Courtois, Nicolas; Hartmann, Daniel J.; Chevalier, Jérôme
2018-01-01
Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies’ prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 °C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.√m. Moreover, the alloy shows a relatively lower Young’s modulus (96 GPa) than the Ti-6Al-4V alloy (110–115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of −0.07 V/SCE and corrosion current density of 6.0 nA/cm2), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants. PMID:29415490
NASA Technical Reports Server (NTRS)
Platts, Steven H.; Summers, Richard L.; Martin, David S.; Meck, Janice V.; Coleman, Thomas G.
2007-01-01
Reentry orthostasis after exposure to the conditions of spaceflight is a persistent problem among astronauts. In a previous study, a computer model systems analysis was used to examine the physiologic mechanisms involved in this phenomenon. In this analysis, it was determined that an augmented capacitance of lower extremity veins due to a fluid volume contracture of the surrounding interstitial spaces during spaceflight results in an increase in sequestered blood volume upon standing and appears to be the initiating mechanism responsible for reentry orthostasis. In this study, we attempt to validate the central premise of this hypothesis using a ground-based spaceflight analog. 10 healthy subjects were placed at bed rest in a 6 head down tilt position for 60 days of bed rest. The impact of adaptations in interstitial fluid volume and venous capacitance in the lower extremities were then observed during a standard tilt test protocol performed before and after the confinement period. The interstitial thickness superficial to the calcaneous immediately below the lateral malleolus was measured using ultrasound with a 17-5 MHz linear array transducer. Measurements of the changes in anterior tibial vein diameter during tilt were obtained by similar methods. The measurements were taken while the subjects were supine and then during upright tilt (80') for thirty minutes, or until the subject had signs of presyncope. Additional measurements of the superficial left tibia interstitial thickness and stroke volume by standard echocardiographic methods were also recorded. In addition, calf compliance was measured over a pressure range of 10-60 mmHg, using plethysmography, in a subset of these subjects (n = 5). There was a average of 6% diminution in the size of the lower extremity interstitial space as compared to measurements acquired prior to bed rest. This contracture of the interstitial space coincided with a subsequent relative increase in the percentage change in tibial vein diameter and stroke volume upon tilting in contrast to the observations made before bed rest (54 vs 23% respectively). Compliance in the calf increased by an average of 36% by day 27 of bedrest. A systems analysis using a computer model of cardiovascular physiology suggests that microgravity induced interstitial volume depletion results in an accentuation of venous blood volume sequestration and is the initiating event in reentry orthostasis. This hypothesis was tested in volunteer subjects using a ground-based spaceflight analog model that simulated the body fluid redistribution induced by microgravity exposure. Measurements of changes in the interstitial spaces and observed responses of the anterior tibial vein with tilt, together with the increase in calf compliance, were consistent with our proposed mechanism for the initiation of postflight orthostasis often seen in astronauts.
Johnson, K A; Rogers, G J; Roe, S C; Howlett, C R; Clayton, M K; Milthorpe, B K; Schindhelm, K
1999-06-01
Collagenous xenografts made from kangaroo tail tendon cross-linked with glutaraldehyde have a potential application in the reconstruction of massive digital tendon deficits. However, a limitation to the clinical use of these xenografts has been the optimization of collagen cross-linking, and subsequent bio-incorporation and retention of mechanical properties following implantation. The purpose of this study was to evaluate the effect of nitrous acid on modulating the biologic and mechanical properties of tendon xenografts cross-linked with glutaraldehyde. Tendon xenografts were pretreated with 0.1 or 0.01 M nitrous acid solution, prior to cross-linking in 2% glutaraldehyde and sterilization by gamma irradiation. Xenografts were implanted intramuscularly in rabbits to examine biocompatability, and also used to repair ovine digital extensor tendon deficits to evaluate functional incorporation. Histologically, intramuscularly implanted nitrous acid pretreated xenografts in rabbits had a greater degree of diffuse cellular infiltration into interstitial splits in the graft than controls after 12 weeks. Xenografts implanted in an ovine extensor tendon deficit were evaluated after 26 and 52 weeks. Rate of failure of tenorrhaphies between host tendon and xenografts overall (15/21) was significantly greater (P < 0.05) than for autografts (1/21), suggesting that the holding power of sutures in xenografts was inferior to that obtained in autografts. Tensile failure stress of midsections of both nitrous acid pretreated and control xenografts was about 100 MPa prior to implantation (time zero). After 26 and 52 weeks, failure stress of both types of xenografts was significantly less than at time zero (P < 0.05). At 52 weeks, failure stress of nitrous acid pretreated xenografts (47.4 +/- 3.1 MPa) was significantly less than control xenografts (63.7 +/- 5.4 MPa); (P < 0.05). However, nitrous acid pretreated xenografts were similar to control xenografts in failure load (357 +/- 29 and 354 +/- 26 N, respectively), but they tended to have larger cross-sectional areas (7.6 +/- 0.5 versus 5.7 +/- 0.6 mm2, respectively) which were responsible for the lower calculated value for failure stress. Histologically, autografts maintained their normal tissue architecture and evoked a more limited cellular response in surrounding tissues than xenografts (P < 0.05). Both types of xenograft were surrounded by a thicker cuff of cellular response than autografts. However, compared to control xenografts, nitrous acid pretreated xenografts had more extensive fragmentation and splitting of collagen bundles, and more diffuse cellular and vascular infiltration into these interstitial splits, and these alterations were apparently contributing to the greater 'swelling' of these xenografts. It was concluded that pretreatment of tendon xenografts with nitrous acid modulated their biologic and material properties. Further studies are needed to elucidate the mechanism of these effects, and to determine if the protocol for tendon xenograft preparation could be optimized for improved clinical performance.
Estimates of point defect production in α-quartz using molecular dynamics simulations
NASA Astrophysics Data System (ADS)
Cowen, Benjamin J.; El-Genk, Mohamed S.
2017-07-01
Molecular dynamics (MD) simulations are performed to investigate the production of point defects in α-quartz by oxygen and silicon primary knock-on atoms (PKAs) of 0.25-2 keV. The Wigner-Seitz (WS) defect analysis is used to identify the produced vacancies, interstitials, and antisites, and the coordination defect analysis is used to identify the under and over-coordinated oxygen and silicon atoms. The defects at the end of the ballistic phase and the residual defects, after annealing, increase with increased PKA energy, and are statistically the same for the oxygen and silicon PKAs. The WS defect analysis results show that the numbers of the oxygen vacancies and interstitials (VO, Oi) at the end of the ballistic phase is the highest, followed closely by those of the silicon vacancies and interstitials (VSi, Sii). The number of the residual oxygen and silicon vacancies and interstitials are statistically the same. In addition, the under-coordinated OI and SiIII, which are the primary defects during the ballistic phase, have high annealing efficiencies (>89%). The over-coordinated defects of OIII and SiV, which are not nearly as abundant in the ballistic phase, have much lower annealing efficiencies (<63%) that decrease with increased PKA energy.
Phillips, Bryn M; Anderson, Brian S; Hunt, John W; Clark, Sara L; Voorhees, Jennifer P; Tjeerdema, Ron S; Casteline, Jane; Stewart, Margaret
2009-02-01
Phase I whole sediment toxicity identification evaluation (TIE) methods have been developed to characterize the cause of toxicity as organic chemicals, metals, or ammonia. In Phase II identification treatments, resins added to whole sediment to reduce toxicity caused by metals and organics can be separated and eluted much like solid-phase extraction (SPE) columns are eluted for interstitial water. In this study, formulated reference sediments spiked with toxic concentrations of copper, fluoranthene, and nonylphenol were subjected to whole sediment and interstitial water TIE treatments to evaluate Phase I and II TIE procedures for identifying the cause of toxicity to Hyalella azteca. Phase I TIE treatments consisted of adding adsorbent resins to whole sediment, and using SPE columns to remove spiked chemicals from interstitial water. Phase II treatments consisted of eluting resins and SPE columns and the preparation and testing of eluates for toxicity and chemistry. Whole sediment resins and SPE columns significantly reduced toxicity, and the eluates from all treatments contained toxic concentrations of the spiked chemical except for interstitial water fluoranthene. Toxic unit analysis based on median lethal concentrations (LC50s) allowed for the comparison of chemical concentrations among treatments, and demonstrated that the bioavailability of some chemicals was reduced in some samples and treatments. The concentration of fluoranthene in the resin eluate closely approximated the original interstitial water concentration, but the resin eluate concentrations of copper and nonylphenol were much higher than the original interstitial water concentrations. Phase II whole sediment TIE treatments provided complementary lines of evidence to the interstitial water TIE results.
Peters, Kenneth M; Jayabalan, Nirmal; Bui, Don; Killinger, Kim; Chancellor, Michael; Tyagi, Pradeep
2015-05-01
Sacral neuromodulation (SNM) may improve interstitial cystitis/painful bladder syndrome (IC/BPS) symptoms of urinary frequency, urgency and perhaps even pain, but objective measures of improvement are lacking. We evaluated the potential for urinary chemokines to serve as measures of treatment response over time to SNM. Women with IC/BPS undergoing SNM consented for this study. Three-day bladder/pain diaries were collected at baseline and validated Interstitial Cystitis Symptom Problem Index (ICSPI) scores and mid-stream urine specimens were collected at baseline and at 24 weeks after successful implant. Collected urine was screened for infection by dipstick and analyzed for chemokines by luminex xMAP analysis. At baseline (n = 16), urine levels of CXCL-1 positively correlated with pain score (r = 0.63, P = 0.009), urgency (r = 0.61, P = 0.01), ICSPI (r = 0.43, P = 0.09) and daily voids (r = 0.44, P = 0.08). ICSPI and pain scores also positively correlated with sIL-1ra (r = 0.50, P = 0.04) and monocyte chemotactic protein-1 (MCP-1) or CCL2 positively correlated with daily voids (r = 0.45, P = 0.07) only. At 24 weeks, the median ICSPI index fell from 28 to 15 (n = 7, P = 0.008). Urine levels of sIL-1ra (633.8 ± 188.2 vs. 149.9 ± 41.62 pg/mL) and MCP-1 (448.3 ± 11.6 vs. 176.9 ± 46.16 pg/mL) and CCL5 (20.78 ± 4.09 vs. 11.21 ± 4.12 pg/mL) were also significantly reduced at the follow-up relative to baseline values (P = 0.04). Multivariable analysis of data revealed that sIL-1ra and MCP-1 together explained the majority of variance in data. Levels of CXCL-1, CXCL-10, interleukin (IL)-8, vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF) were also reduced at 24 weeks, but differences were not significant. Concomitant decrease in urine levels of chemokines especially MCP-1 was associated with treatment response of SNM. These results support the role of chemokines as downstream effectors of neuromodulation response and could serve as potential non-invasive measures of treatment response. NCT01739946. © 2014 Wiley Publishing Asia Pty Ltd.
"Smart tattoo" glucose biosensors and effect of coencapsulated anti-inflammatory agents.
Srivastava, Rohit; Jayant, Rahul Dev; Chaudhary, Ayesha; McShane, Michael J
2011-01-01
Minimally invasive glucose biosensors with increased functional longevity form one of the most promising techniques for continuous glucose monitoring. In the present study, we developed a novel nanoengineered microsphere formulation comprising alginate microsphere glucose sensors and anti-inflammatory-drug-loaded alginate microspheres. The formulation was prepared and characterized for size, shape, in vitro drug release, biocompatibility, and in vivo acceptability. Glucose oxidase (GOx)- and Apo-GOx-based glucose sensors were prepared and characterized. Sensing was performed both in distilled water and simulated interstitial body fluid. Layer-by-layer self-assembly techniques were used for preventing drug and sensing chemistry release. Finally, in vivo studies, involving histopathologic examination of subcutaneous tissue surrounding the implanted sensors using Sprague-Dawley rats, were performed to test the suppression of inflammation and fibrosis associated with glucose sensor implantation. The drug formulation showed 100% drug release with in 30 days with zero-order release kinetics. The GOx-based sensors showed good enzyme retention and enzyme activity over a period of 1 month. Apo-GOx-based visible and near-infrared sensors showed good sensitivity and analytical response range of 0-50 mM glucose, with linear range up to 12 mM glucose concentration. In vitro cell line studies proved biocompatibility of the material used. Finally, both anti-inflammatory drugs were successful in controlling the implant-tissue interface by suppressing inflammation at the implant site. The incorporation of anti-inflammatory drug with glucose biosensors shows promise in improving sensor biocompatibility, thereby suggesting potential application of alginate microspheres as "smart tattoo" glucose sensors with increased functional longevity. © 2010 Diabetes Technology Society.
Atomic diffusion in strain fields near solutes
NASA Astrophysics Data System (ADS)
Shropshire, Steven L.; Collins, Gary S.
1993-03-01
Annihilation reactions between mobile self-interstitial defects and complexes of vacancies with111In probe solutes in Au were studied. Measurements were made using the technique of perturbed angular correlations of gamma rays (PAC). Au samples were doped with complexes and plastically deformed at a low temperature to generate fluxes of self-interstitials. Changes in the concentrations of monovacancy (1V) to tetravacancy (4V) complexes induced by annihilation reactions were measured. These are now analysed using a system of coupled first-order equations in order to obtain interstitial annihilation cross sections of the complexes and the fractional amounts of different interstitial clusters in the flux. Relative cross sections obtained for Au are 1.0(1), 3.3(3), 1.2(2) and 7.5(2.5), respectively, for 1V to 4V complexes. The large increase in the cross sections with vacancy number is attributed to a progressive relaxation of the dilatational strain surrounding the oversized In solute as more vacancies are trapped. Also obtained from the analysis are values 0.34(5), 0.66(7), 0.0(1) and 0.0(2), respectively, for the fractions of mobile 1I to 4I clusters in deformed Au, indicating that di-interstitials are produced more readily than mono-interstitials during plastic deformation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayedh, H. M.; Svensson, B. G.; Hallén, A.
The carbon vacancy (V{sub C}) is a prevailing point defect in high-purity 4H-SiC epitaxial layers, and it plays a decisive role in controlling the charge carrier lifetime. One concept of reducing the V{sub C}-concentration is based on carbon self-ion implantation in a near surface layer followed by thermal annealing. This leads to injection of carbon interstitials (C{sub i}'s) and annihilation of V{sub C}'s in the epi-layer “bulk”. Here, we show that the excess of C atoms introduced by the self-ion implantation plays a negligible role in the V{sub C} annihilation. Actually, employing normalized implantation conditions with respect to displaced Cmore » atoms, other heavier ions like Al and Si are found to be more efficient in annihilating V{sub C}'s. Concentrations of V{sub C} below ∼2 × 10{sup 11} cm{sup −3} can be reached already after annealing at 1400 °C, as monitored by deep-level transient spectroscopy. This corresponds to a reduction in the V{sub C}-concentration by about a factor of 40 relative to the as-grown state of the epi-layers studied. The negligible role of the implanted species itself can be understood from simulation results showing that the concentration of displaced C atoms exceeds the concentration of implanted species by two to three orders of magnitude. The higher efficiency for Al and Si ions is attributed to the generation of collision cascades with a sufficiently high energy density to promote C{sub i}-clustering and reduce dynamic defect annealing. These C{sub i}-related clusters will subsequently dissolve during the post-implant annealing giving rise to enhanced C{sub i} injection. However, at annealing temperatures above 1500 °C, thermodynamic equilibrium conditions start to apply for the V{sub C}-concentration, which limit the net effect of the C{sub i} injection, and a competition between the two processes occurs.« less
First-Principles Study of Carbon and Vacancy Structures in Niobium
Ford, Denise C.; Zapol, Peter; Cooley, Lance D.
2015-04-03
The interstitial chemical impurities hydrogen, oxygen, nitrogen, and carbon are important for niobium metal production, and particularly for the optimization of niobium SRF technology. These atoms are present in refined sheets and can be absorbed into niobium during processing treatments, resulting in changes to the residual resistance and the performance of SRF cavities. A first-principles approach is taken to study the properties of carbon in niobium, and the results are compared and contrasted with the properties of the other interstitial impurities. The results indicate that C will likely form precipitates or atmospheres around defects rather than strongly bound complexes withmore » other impurities. Based on the analysis of carbon and hydrogen near niobium lattice vacancies and small vacancy chains and clusters, the formation of extended carbon chains and hydrocarbons is not likely to occur. Association of carbon with hydrogen atoms can, however, occur through the strain fields created by interstitial binding of the impurity atoms. In conclusion, calculated electronic densities of states indicate that interstitial C may have a similar effect as interstitial O on the superconducting transition temperature of Nb.« less
Mori, Takefumi; Cowley, Allen W
2004-04-01
Renal perfusion pressure was servo-controlled chronically in rats to quantify the relative contribution of elevated arterial pressure versus angiotensin II (Ang II) on the induction of renal injury in Ang II-induced hypertension. Sprague-Dawley rats fed a 4% salt diet were administered Ang II for 14 days (25 ng/kg per minute IV; saline only for sham rats), and the renal perfusion pressure to the left kidney was continuously servo-controlled to maintain a normal pressure in that kidney throughout the period of hypertension. An aortic occluder was implanted around the aorta between the two renal arteries and carotid and femoral arterial pressure were measured continuously throughout the experiment to determine uncontrolled and controlled renal perfusion pressure, respectively. Renal perfusion pressure of uncontrolled, controlled, and sham kidneys over the period of Ang II or saline infusion averaged 152.6+/-7.0, 117.4+/-3.5, and 110.7+/-2.2 mm Hg, respectively. The high-pressure uncontrolled kidneys exhibited tubular necrosis and interstitial fibrosis, especially prominent in the outer medullary region. Regional glomerular sclerosis and interlobular artery injury were also pronounced. Controlled kidneys were significantly protected from interlobular artery injury, juxtamedullary glomeruli injury, tubular necrosis, and interstitial fibrosis as determined by comparing the level of injury. Glomerular injury was not prevented in the outer cortex. Transforming growth factor (TGF)-beta and active NF-kappaB proteins determined by immunohistochemistry were colocalized in the uncontrolled kidney in regions of interstitial fibrosis. We conclude that the preferential juxtamedullary injury found in Ang II hypertension is largely induced by pressure and is probably mediated through the TGF-beta and NF-kappaB pathway.
Optical microsensor for continuous glucose measurements in interstitial fluid
NASA Astrophysics Data System (ADS)
Olesberg, Jonathon T.; Cao, Chuanshun; Yager, Jeffrey R.; Prineas, John P.; Coretsopoulos, Chris; Arnold, Mark A.; Olafsen, Linda J.; Santilli, Michael
2006-02-01
Tight control of blood glucose levels has been shown to dramatically reduce the long-term complications of diabetes. Current invasive technology for monitoring glucose levels is effective but underutilized by people with diabetes because of the pain of repeated finger-sticks, the inconvenience of handling samples of blood, and the cost of reagent strips. A continuous glucose sensor coupled with an insulin delivery system could provide closed-loop glucose control without the need for discrete sampling or user intervention. We describe an optical glucose microsensor based on absorption spectroscopy in interstitial fluid that can potentially be implanted to provide continuous glucose readings. Light from a GaInAsSb LED in the 2.2-2.4 μm wavelength range is passed through a sample of interstitial fluid and a linear variable filter before being detected by an uncooled, 32-element GaInAsSb detector array. Spectral resolution is provided by the linear variable filter, which has a 10 nm band pass and a center wavelength that varies from 2.18-2.38 μm (4600-4200 cm -1) over the length of the detector array. The sensor assembly is a monolithic design requiring no coupling optics. In the present system, the LED running with 100 mA of drive current delivers 20 nW of power to each of the detector pixels, which have a noise-equivalent-power of 3 pW/Hz 1/2. This is sufficient to provide a signal-to-noise ratio of 4500 Hz 1/2 under detector-noise limited conditions. This signal-to-noise ratio corresponds to a spectral noise level less than 10 μAU for a five minute integration, which should be sufficient for sub-millimolar glucose detection.
Kayler, Liise K; Mohanka, Ravi; Basu, Amit; Shapiro, Ron; Randhawa, Parmjeet S
2009-01-01
Transplantation of kidneys from donor with arteriosclerosis seen on pre-implantation biopsy has not been well studied. We retrospectively evaluated 20 dual kidney transplant (DKT) and 28 single (SKT) kidney transplant recipients with >or=12 months follow-up from donors with moderate arteriosclerosis (>or=25% luminal diameter narrowing). Death censored graft survival was 100% and 79%, respectively (p = 0.0339). DKT recipients had significantly lower mean creatinine levels at one, three, six, and nine months and spent somewhat less time on the waiting list (181 +/- 160 vs. 318 +/- 306 d, p = 0.1429). DKT patients received kidneys from significantly older donors (64 +/- 7 vs. 54 +/- 11 yr; p = 0.0012), proportionately more expanded criteria donors (95% vs. 54%; p = 0.0029), and more donors with hypertension (81% vs. 48%, p = 0.0344) and death related to cerebrovascular accident (100% vs. 71%, p = 0.0143); however, more DKT kidneys underwent machine perfusion (95% vs. 57%, p = 0.0068). Baseline recipient variables were comparable between the two groups including age, race, gender, retransplantation, and HLA mismatch. Pre-implant biopsy was notable for similar frequencies of moderate interstitial fibrosis (10% vs. 14%, respectively) and glomerulosclerosis. Among recipients of deceased-donor kidneys with >25% arteriosclerosis, short-term outcomes after DKT were superior to that of SKT grafts. This approach may help to expand the donor-organ pool while optimizing outcomes.
NASA Astrophysics Data System (ADS)
Coleman, P. G.; Nash, D.; Edwardson, C. J.; Knights, A. P.; Gwilliam, R. M.
2011-07-01
Variable-energy positron annihilation spectroscopy (VEPAS) has been applied to the study of the formation and evolution of vacancy-type defect structures in silicon (Si) and the 1.5 μm thick Si top layer of silicon-on-insulator (SOI) samples. The samples were implanted with 2 MeV Si ions at fluences between 1013 and 1015 cm-2, and probed in the as-implanted state and after annealing for 30 min at temperatures between 350 and 800 °C. In the case of SOI the ions were implanted such that their profile was predominantly in the insulating buried oxide layer, and thus their ability to combine with vacancies in the top Si layer, and that of other interstitials beyond the buried oxide, was effectively negated. No measurable differences in the positron response to the evolution of small clusters of n vacancies (Vn, n ˜ 3) in the top Si layer of the Si and SOI samples were observed after annealing up to 500 °C; at higher temperatures, however, this response persisted in the SOI samples as that in Si decreased toward zero. At 700 and 800 °C the damage in Si was below detectable levels, but the VEPAS response in the top Si layer in the SOI was consistent with the development of nanovoids.
Effects of antimony (Sb) on electron trapping near SiO{sub 2}/4H-SiC interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mooney, P. M.; Jiang, Zenan; Basile, A. F.
To investigate the mechanism by which Sb at the SiO{sub 2}/SiC interface improves the channel mobility of 4H-SiC MOSFETs, 1 MHz capacitance measurements and constant capacitance deep level transient spectroscopy (CCDLTS) measurements were performed on Sb-implanted 4H-SiC MOS capacitors. The measurements reveal a significant concentration of Sb donors near the SiO{sub 2}/SiC interface. Two Sb donor related CCDLTS peaks corresponding to shallow energy levels in SiC were observed close to the SiO{sub 2}/SiC interface. Furthermore, CCDLTS measurements show that the same type of near-interface traps found in conventional dry oxide or NO-annealed capacitors are present in the Sb implanted samples. Thesemore » are O1 traps, suggested to be carbon dimers substituted for O dimers in SiO{sub 2}, and O2 traps, suggested to be interstitial Si in SiO{sub 2}. However, electron trapping is reduced by a factor of ∼2 in Sb-implanted samples compared with samples with no Sb, primarily at energy levels within 0.2 eV of the SiC conduction band edge. This trap passivation effect is relatively small compared with the Sb-induced counter-doping effect on the MOSFET channel surface, which results in improved channel transport.« less
Severe interstitial pneumonia due to murine typhus in a patient returning from Bali.
Malheiro, Luís; Ceia, Filipa; Alves, João; Carvalho, Ana Cláudia; Sobrinho-Simões, Joana; Sousa, Rita; Sarmento, António; Santos, Lurdes
2017-01-01
Murine typhus has been increasingly reported as a cause of fever in returning travelers from Southeast Asia. We report a case of a previously healthy traveler returning from Bali with an non-specific febrile illness which quickly progressed to a severe form of interstitial pneumonia. After a careful epidemiological evaluation and laboratory analysis, murine typhus was diagnosed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S; Kamrava, M; Yang, Y
Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI wasmore » acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.« less
Ab initio theory of noble gas atoms in bcc transition metals.
Jiang, Chao; Zhang, Yongfeng; Gao, Yipeng; Gan, Jian
2018-06-18
Systematic ab initio calculations based on density functional theory have been performed to gain fundamental understanding of the interactions between noble gas atoms (He, Ne, Ar and Kr) and bcc transition metals in groups 5B (V, Nb and Ta), 6B (Cr, Mo and W) and 8B (Fe). Our charge density analysis indicates that the strong polarization of nearest-neighbor metal atoms by noble gas interstitials is the electronic origin of their high formation energies. Such polarization becomes more significant with an increasing gas atom size and interstitial charge density in the host bcc metal, which explains the similar trend followed by the unrelaxed formation energies of noble gas interstitials. Upon allowing for local relaxation, nearby metal atoms move farther away from gas interstitials in order to decrease polarization, albeit at the expense of increasing the elastic strain energy. Such atomic relaxation is found to play an important role in governing both the energetics and site preference of noble gas atoms in bcc metals. Our most notable finding is that the fully relaxed formation energies of noble gas interstitials are strongly correlated with the elastic shear modulus of the bcc metal, and the physical origin of this unexpected correlation has been elucidated by our theoretical analysis based on the effective-medium theory. The kinetic behavior of noble gas atoms and their interaction with pre-existing vacancies in bcc transition metals have also been discussed in this work.
NASA Astrophysics Data System (ADS)
Wakimoto, Hiroki; Nakazawa, Haruo; Matsumoto, Takashi; Nabetani, Yoichi
2018-04-01
For P-i-N diodes implanted and activated with boron ions into a highly-resistive n-type Si substrate, it is found that there is a large difference in the leakage current between relatively low temperature furnace annealing (FA) and high temperature laser annealing (LA) for activation of the p-layer. Since electron trap levels in the n-type Si substrate is supposed to be affected, we report on Deep Level Transient Spectroscopy (DLTS) measurement results investigating what kinds of trap levels are formed. As a result, three kinds of electron trap levels are confirmed in the region of 1-4 μm from the p-n junction. Each DLTS peak intensity of the LA sample is smaller than that of the FA sample. In particular, with respect to the trap level which is the closest to the silicon band gap center most affecting the reverse leakage current, it was not detected in LA. It is considered that the electron trap levels are decreased due to the thermal energy of LA. On the other hand, four kinds of trap levels are confirmed in the region of 38-44 μm from the p-n junction and the DLTS peak intensities of FA and LA are almost the same, considering that the thermal energy of LA has not reached this area. The large difference between the reverse leakage current of FA and LA is considered to be affected by the deep trap level estimated to be the interstitial boron.
Detection of Quadrupole Interactions by Muon Level Crossing Resonance
NASA Astrophysics Data System (ADS)
Cox, S. F. J.
1992-02-01
The positive muon proves to be a very versatile and sensitive magnetic resonance probe: implanted in virtually any material its polarisation may be monitored via the asymmetry in its radioactive decay, giving information on the sites occupied by the muon in lattices or molecules, and the local fields experienced at these sites. The scope of these experiments has been greatly extended by the development of a technique of cross relaxation or level crossing resonance which allows quadrupole splittings on nuclei adjacent to the muon to be measured. The principles of the technique and the conditions necessary for detection of the spectra are described, together with a number of applications. Of especial interest is the manner in which muons mimic the behaviour of protons in matter. In metal lattices, for instance, muons invariably adopt the same interstitial sites as do protons in the dilute hydride phases, so that they can be used to study problems of localisation and diffusion common to those of hydrogen in metals. Studies of the muon level crossing resonance in copper have given valuable information on the crystallographic site, electronic structure and low temperature mobility of the interstitial defect. In semiconductors, muons are expected to trap at other impurities - notably acceptors - in processes analogous to the passivation of dopants by hydrogen. Muon resonance offers the exciting prospect of spectroscopic study of these passivation complexes. In molecular materials, substitution of protons by muons can be thought of rather like deuteration. Muons implanted in ice produce a significant change in the quadrupole coupling constant of adjacent 17O nuclei which may be traced to the effects of the large muon zero point energy; the resonance spectrum also exhibits temperature dependent features which may be informative on the nature and lifetime of defects in the ice structure. Muon level crossing resonance has already been studied in an oxide superconductor and this relatively young field is now wide open for quadrupole interaction studies in other materials, using a variety of nuclei.
Energetics analysis of interstitial loops in single-phase concentrated solid-solution alloys
NASA Astrophysics Data System (ADS)
Wang, Xin-Xin; Niu, Liang-Liang; Wang, Shaoqing
2018-04-01
Systematic energetics analysis on the shape preference, relative stability and radiation-induced segregation of interstitial loops in nickel-containing single-phase concentrated solid-solution alloys have been conducted using atomistic simulations. It is shown that the perfect loops prefer rhombus shape for its low potential energy, while the Frank faulted loops favor ellipse for its low potential energy and the possible large configurational entropy. The decrease of stacking fault energy with increasing compositional complexity provides the energetic driving force for the formation of faulted loops, which, in conjunction with the kinetic factors, explains the experimental observation that the fraction of faulted loops rises with increasing compositional complexity. Notably, the kinetics is primarily responsible for the absence of faulted loops in nickel-cobalt with a very low stacking fault energy. We further demonstrate that the simultaneous nickel enrichment and iron/chromium depletion on interstitial loops can be fully accounted for by their energetics.
Quantifying macropore recharge: Examples from a semi-arid area
Wood, W.W.; Rainwater, Ken A.; Thompson, D.B.
1997-01-01
The purpose of this paper is to illustrate the significantly increased resolution of determining macropore recharge by combining physical, chemical, and isotopic methods of analysis. Techniques for quantifying macropore recharge were developed for both small-scale (1 to 10 km2) and regional-scale areas in and semi-arid areas. The Southern High Plains region of Texas and New Mexico was used as a representative field site to test these methods. Macropore recharge in small-scale areas is considered to be the difference between total recharge through floors of topographically dosed basins and interstitial recharge through the same area. On the regional scale, macropore recharge was considered to be the difference between regional average annual recharge and interstitial recharge measured in the unsaturated zone. Stable isotopic composition of ground water and precipitation was used us an independent estimate of macropore recharge on the regional scale. Results of this analysis suggest that in the Southern High Plains recharge flux through macropores is between 60 and 80 percent of the total 11 mm/y. Between 15 and 35 percent of the recharge occurs by interstitial recharge through the basin floors. Approximately 5 percent of the total recharge occurs as either interstitial or matrix recharge between the basin floors, representing approximately 95 percent of the area. The approach is applicable to other arid and semi-arid areas that focus rainfall into depressions or valleys.The purpose of this paper is to illustrate the significantly increased resolution of determining macropore recharge by combining physical, chemical, and isotopic methods of analysis. Techniques for quantifying macropore recharge were developed for both small-scale (1 to 10 km2) and regional-scale areas in arid and semi-arid areas. The Southern High Plains region of Texas and New Mexico was used as a representative field site to test these methods. Macropore recharge in small-scale areas is considered to be the difference between total recharge through floors of topographically closed basins and interstitial recharge through the same area. On the regional scale, macropore recharge was considered to be the difference between regional average annual recharge and interstitial recharge measured in the unsaturated zone. Stable isotopic composition of ground water and precipitation was used as an independent estimate of macropore recharge on the regional scale. Results of this analysis suggest that in the Southern High Plains recharge flux through macropores is between 60 and 80 percent of the total 11 mm/y. Between 15 and 35 percent of the recharge occurs by interstitial recharge through the basin floors. Approximately 5 percent of the total recharge occurs as either interstitial or matrix recharge between the basin floors, representing approximately 95 percent of the area. The approach is applicable to other arid and semi-arid areas that focus rainfall into depressions or valleys.
Interstitial duplication 8q22-q24: Report of a case proven by FISH with mapped cosmid probes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wakui, Keiko; Ohashi, Hirofumi; Yamagishi, Akira
We report on a 6-month-old malformed female infant with a de novo interstitial duplication of an 8q22-q24 segment. She had an excess dark-band on the 8q distal region by GTG-banded chromosome analysis, which was likely to be 8q23. We performed FISH analysis using cosmid probes mapped to 8q23 and proved that the patient had an 8q duplication including the 8q23 region. 20 refs., 2 figs., 1 tab.
NASA Astrophysics Data System (ADS)
Isabelle, Martin; O'Hara, Julia A.; Samkoe, Kimberley S.; Hoopes, P. Jack; Mosse, Sandy; Pereira, Stephen; Hasan, Tayyaba; Pogue, Brian W.
2010-02-01
Photodynamic therapy (PDT) mediated with Verteporfin is being investigated as a pancreatic cancer treatment in the cases for non-surgical candidates. Tissue response to PDT is based on a number of parameters including photosensitizer (PS) dose, light dose and time interval between light application and PS injection. In this study, PS uptake and distribution in animal leg muscle, oral cavity tissues, pancreas and tumor was measured in vivo using light-induced fluorescence spectroscopy (LIFS) via an Aurora Optics Inc. PDT fluorescence dosimeter. An orthotopic pancreatic cancer model (AsPC-1) was implanted in SCID mice and treated with the PS. Probe measurements were made using a surface probe and an interstitial needle probe before and up to one hour after intravenous tail vein injection of the PS. The study demonstrated that it is possible to correlate in-vivo LIFS measurements of the PS uptake in the pancreas with measurements taken from the oral cavity indicating that light dosimetry of PDT of the pancreas can be ascertained from the LIFS measurements in the oral cavity. These results emphasize the importance of light dosimetry in improving the therapeutic outcome of PDT through light dose adaptation to the relative in situ tissue PS concentration.
NASA Astrophysics Data System (ADS)
Ito, T. U.; Koda, A.; Shimomura, K.; Higemoto, W.; Matsuzaki, T.; Kobayashi, Y.; Kageyama, H.
2017-01-01
Excited configurations of hydrogen in the oxyhydride BaTiO3 -xHx (x =0.1 -0.5 ), which are considered to be involved in its hydrogen transport and exchange processes, were investigated by positive muon spin relaxation spectroscopy using muonium (Mu) as a pseudoisotope of hydrogen. Muons implanted into the BaTiO3 -xHx perovskite lattice were mainly found in two qualitatively different metastable states. One was assigned to a highly mobile interstitial protonic state, which is commonly observed in perovskite oxides. The other was found to form an entangled two spin-1/2 system with the nuclear spin of an H- ion at the anion site. The structure of the (H,Mu) complex agrees well with that of a neutralized center containing two H- ions at a doubly charged oxygen vacancy, which was predicted to form in the SrTiO3 -δ perovskite lattice by a computational study [Y. Iwazaki et al., APL Mater. 2, 012103 (2014), 10.1063/1.4854355]. Above 100 K, interstitial Mu+ diffusion and retrapping to a deep defect were observed, which could be a rate-limiting step of macroscopic Mu/H transport in the BaTiO3 -xHx lattice.
Kim, Sung Han; Oh, Shin Ah; Oh, Seung-June
2014-02-01
To identify the voiding characteristics of bladder pain syndrome/interstitial cystitis and overactive bladder. Between September 2005 and June 2010, 3-day voiding diaries of 49 consecutive bladder pain syndrome/interstitial cystitis patients and 301 overactive bladder patients were prospectively collected at an outpatient clinic and retrospectively analyzed. The characteristics of the two groups were not significantly different. However, all voiding variables including volume and frequency were significantly different except for the total voided volume: patients with bladder pain syndrome/interstitial cystitis showed significantly higher voiding frequencies, smaller maximal and mean voided volume, and more constant and narrower ranges of voided volume compared with overactive bladder patients (P < 0.005). Furthermore, mean intervals between voiding in bladder pain syndrome/interstitial cystitis were shorter and more consistent during the day and night (P < 0.001), although mean night-time variances were greater than daytime variances. Logistic regression analysis showed that total night-time frequency, maximal night-time voided volume and mean variance of daytime voiding intervals most significantly differentiated the two groups. Some voiding characteristics of bladder pain syndrome/interstitial cystitis and overactive bladder patients differ significantly according to 3-day voiding diary records. These findings provide additional information regarding the differences between these two diseases in the outpatient clinical setting. © 2013 The Japanese Urological Association.
NASA Astrophysics Data System (ADS)
MacMahon, Heber; Vyborny, Carl; Sabeti, Victoria; Metz, Charles; Doi, Kunio
1985-09-01
A potential advantage of digital radiographic systems is their ability to enhance images by various types of processing. Digital unsharp masking is one of the simplest and potentially most useful forms of enhancement. The efficacy of unsharp masking in clinical radiologic diagnosis has not been investigated systematically, however. The effect of digital unsharp masking on the detectability of two types of subtle abnormalities, pneumothorax and interstitial infiltrate, was studied in an observer performance test. An ROC analysis of this preliminary data suggests that unsharp masking may improve diagnostic accuracy for pneumothorax. Radiologists' performance in identifying interstitial infiltrates was degraded by the image processing, however, and false positive diagnoses tended to be more frequent.
Giant-cell interstitial pneumonia in a gas station worker.
Lee, S M; Moon, C H; Oh, Y B; Kim, H Y; Ahn, Y; Ko, E J; Joo, J E
1998-10-01
Giant-cell interstitial Pneumonia (GIP) is a very uncommon respiratory disease. The majority of cases of GIP are caused by exposure to cobalt, tungsten and other hard metals. In this report, we describe GIP in a patient who worked in gas station and dealt in propane gas vessels. He presented with clinical features of chronic interstitial lung disease and underwent an open lung biopsy that showed DIP-like reaction with large numbers of intra-alveolar macrophages and numerous large, multinucleated histiocytes which were admixed with the macrophages. Analysis of lung tissue for hard metals was done. Cobalt was the main component of detected hard metals. Corticosteroid therapy was started and he recovered fully.
Radiation-enhanced self- and boron diffusion in germanium
NASA Astrophysics Data System (ADS)
Schneider, S.; Bracht, H.; Klug, J. N.; Hansen, J. Lundsgaard; Larsen, A. Nylandsted; Bougeard, D.; Haller, E. E.
2013-03-01
We report experiments on proton radiation-enhanced self- and boron (B) diffusion in germanium (Ge) for temperatures between 515 ∘C and 720 ∘C. Modeling of the experimental diffusion profiles measured by means of secondary ion mass spectrometry is achieved on the basis of the Frenkel pair reaction and the interstitialcy and dissociative diffusion mechanisms. The numerical simulations ascertain concentrations of Ge interstitials and B-interstitial pairs that deviate by several orders of magnitude from their thermal equilibrium values. The dominance of self-interstitial related defects under irradiation leads to an enhanced self- and B diffusion in Ge. Analysis of the experimental profiles yields data for the diffusion of self-interstitials (I) and the thermal equilibrium concentration of BI pairs in Ge. The temperature dependence of these quantities provides the migration enthalpy of I and formation enthalpy of BI that are compared with recent results of atomistic calculations. The behavior of self- and B diffusion in Ge under concurrent annealing and irradiation is strongly affected by the property of the Ge surface to hinder the annihilation of self-interstitials. The limited annihilation efficiency of the Ge surface can be caused by donor-type surface states favored under vacuum annealing, but the physical origin remains unsolved.
Anterior vaginal wall tenderness (AVWT) as a physical symptom in chronic pelvic pain.
Paulson, John D; Paulson, Joseph N
2011-01-01
Chronic pelvic pain is often difficult to diagnose and treat properly. Physicians called on to treat this problem may not be able to give a specific diagnosis. The aim of this study was to see whether the physical presence of anterior vaginal wall tenderness could help narrow down and elucidate diagnoses in a practice focusing on diagnosis and treatment of chronic pelvic pain. The study cohort comprised 284 patients with chronic pelvic pain limited to gynecologic and lower urinary problems. Histories, physical examinations, and endoscopic procedures were performed on each patient. An analysis of this information was conducted. Of the chronic pelvic pain patients, 78% had endometriosis, 81% had interstitial cystitis, and 61% had both concurrently. The sensitivity of anterior vaginal wall tenderness (AVWT) in patients with interstitial cystitis was 95%, and in those with only endometriosis and no interstitial cystitis, the sensitivity was 17%. The positive predictive value for interstitial cystitis was 85%, and for endometriosis it was 67%. Examination of the anterior vaginal wall with an empty bladder at the initial examination can lead one to suspect interstitial cystitis and possibly either concomitant or singular endometriosis and allow the physician to approach the workup accordingly.
Interstitial irradiation as a salvage technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syed, A.M.N.
1981-11-01
Forty patients with recurrent pelvic malignancies were irradiated using temporary /sup 192/Ir and/or permanent /sup 125/I implants. All patients had a previous course of pelvic irradiation to doses of 5,000 to 6,000 rad over five to eight weeks; patients with cervical and vaginal carcinomas had intracavitary irradiation as well (3,000 to 5,000 mg-hrs). Overall local control was achieved in 27 of 40 patients (67.5%); 13 of these patients remain alive to a minimum follow-up period of 2 years. Eighty percent of the patients experienced good paliation of pain, bleeding, lymphadema of legs, etc. Overall complicatin rate has been 20%, withmore » three patients having developed enterovaginal and vesicovaginal fistulae. (JMT)« less
NASA Astrophysics Data System (ADS)
Rudenkov, A. S.; Piliptsou, D. G.; Luchnikov, P. A.; Rogachev, A. V.; Jiang, Xiaohong; Fedosenko, N. N.
2018-01-01
The Raman spectroscopy method established that subsequent treatment with ion ions leads to a change in the microstructure of coatings based on carbon and metals. It is established that the structure change is determined by the changes occurring at the interface and depends on the sp3 → sp2 phase transition due to the appearance of local thermal peaks at the end of tracks of nitrogen ions implanted in the coating volume. It is shown that the microhardness of metal-carbon coatings (α-C: Cu, α-C: Ti, α-C:Al) increases after ion-plasma treatment, which is determined by the formation of solid interstitial phases based on CNx and metal carbonitrides.
Maruyama, Takashi; Fukuda, Noboru; Matsumoto, Taro; Kano, Koichiro; Endo, Morito; Kazama, Minako; Kazama, Tomohiko; Ikeda, Jin; Matsuda, Hiroyuki; Ueno, Takahiro; Abe, Masanori; Okada, Kazuyoshi; Soma, Masayoshi; Matsumoto, Koichi; Kawachi, Hiroshi
2015-04-16
Implantation of mesenchymal stem cells (MSCs) has recently been reported to repair tissue injuries through anti-inflammatory and immunosuppressive effects. We established dedifferentiated fat (DFAT) cells that show identical characteristics to MSCs. We examined the effects of 10(6) of DFAT cells infused through renal artery or tail vein on monoclonal antibody (mAb) 1-22-3-induced glomerulonephritis (as an immunological type of renal injury) and adriamycin-induced nephropathy (as a non-immunological type of renal injury) in rats. The mAb 1-22-3-injected rats were also implanted with 10(6) of DFAT cells transfected with TSG-6 siRNA through tail vein. Although DFAT cells transfused into blood circulation through the tail vein were trapped mainly in lungs without reaching the kidneys, implantation of DFAT cells reduced proteinuria and improved glomerulosclerosis and interstitial fibrosis. Implantation of DFAT cells through the tail vein significantly decreased expression of kidney injury molecule-1, collagen IV and fibronectin mRNAs, whereas nephrin mRNA expression was increased. Implantation of DFAT cells did not improve adriamycin-induced nephropathy, but significantly decreased the glomerular influx of macrophages, common leukocytes and pan T cells. However, the glomerular influx of helper T cells, was increased. Implantation of DFAT cells decreased expression of interleukin (IL)-6 and IL-12β mRNAs and increased expression of TNF-stimulated gene (TSG)-6 mRNA in renal cortex from mAb 1-22-3-injected rats. The basal level of TSG-6 protein was significantly higher in DFAT cells than in fibroblasts. Expression of TSG-6 mRNA in MCs cocultured with DFAT cells was significantly higher than in mesangial cells or DFAT cells alone. Systematic implantation of DFAT cells with TSG-6 siRNA through tail vein did not improve proteinuria, renal dysfunction and renal degeneration in the mAb 1-22-3-injected rats. Systematic implantation of DFAT cells effectively ameliorated mAb 1-22-3-induced glomerulonephritis through immunosuppressive effects accompanied by the suppression of macrophage infiltration and expression of IL-6, IL-10 and IL-12β, and increased production of serum and renal TSG-6 that improved the mAb 1-22-3-induced renal degeneration by the immunosuppressive effects of TSG-6. Thus DFAT cells will be suitable cell source for the treatment of immunological progressive renal diseases.
Foster, Derek M.; Martin, Luke G.; Papich, Mark G.
2016-01-01
Bacterial pneumonia is the most common reason for parenteral antimicrobial administration to beef cattle in the United States. Yet there is little information describing the antimicrobial concentrations at the site of action. The objective of this study was to compare the active drug concentrations in the pulmonary epithelial lining fluid and interstitial fluid of four antimicrobials commonly used in cattle. After injection, plasma, interstitial fluid, and pulmonary epithelial lining fluid concentrations and protein binding were measured to determine the plasma pharmacokinetics of each drug. A cross-over design with six calves per drug was used. Following sample collection and drug analysis, pharmacokinetic calculations were performed. For enrofloxacin and metabolite ciprofloxacin, the interstitial fluid concentration was 52% and 78% of the plasma concentration, while pulmonary fluid concentrations was 24% and 40% of the plasma concentration, respectively. The pulmonary concentrations (enrofloxacin + ciprofloxacin combined) exceeded the MIC90 of 0.06 μg/mL at 48 hours after administration. For florfenicol, the interstitial fluid concentration was almost 98% of the plasma concentration, and the pulmonary concentrations were over 200% of the plasma concentrations, exceeding the breakpoint (≤ 2 μg/mL), and the MIC90 for Mannheimia haemolytica (1.0 μg/mL) for the duration of the study. For ceftiofur, penetration to the interstitial fluid was only 5% of the plasma concentration. Pulmonary epithelial lining fluid concentration represented 40% of the plasma concentration. Airway concentrations exceeded the MIC breakpoint for susceptible respiratory pathogens (≤ 2 μg/mL) for a short time at 48 hours after administration. The plasma and interstitial fluid concentrations of tulathromcyin were lower than the concentrations in pulmonary fluid throughout the study. The bronchial concentrations were higher than the plasma or interstitial concentrations, with over 900% penetration to the airways. Despite high diffusion into the bronchi, the tulathromycin concentrations achieved were lower than the MIC of susceptible bacteria at most time points. PMID:26872361
Roth, Wolff-Michael
2014-09-01
Psychology studies the human mind and its development. Although it is often recognized that the human mind needs to be understood as a temporal (developmental) phenomenon between past and future and at the interstices between the idealities of pure Self and Other, the analytic methods interpretive researchers use tend to reify ahistorical and solipsist conceptions of the human being. In this article, I provide examples of an approach to the analysis of verbal data that immediately gets us to the interstitial and syncopic nature of the human psyche.
Doxorubicin-loaded Zein in situ gel for interstitial chemotherapy.
Cao, Xiaoying; Geng, Jianning; Su, Suwen; Zhang, Linan; Xu, Qian; Zhang, Li; Xie, Yinghua; Wu, Shaomei; Sun, Yongjun; Gao, Zibin
2012-01-01
A novel drug delivery system of doxorubicin (DOX)-loaded Zein in situ gel for interstitial chemotherapy was investigated in this study. The possible mechanisms of drug release were described according to morphological analysis by optical microscopy and scanning electronic microscope (SEM). In vitro and in vivo anti-tumor activity studies showed that DOX-loaded Zein in situ gel was superior to DOX solution. Local pharmacokinetics in tumor tissue was studied by quantitative analysis with confocal laser scanning microscopy (CLSM) combined with microdialysis technology. A pharmacokinetics mathematical model of DOX-loaded Zein in situ gel in tumors was then built.
Deidda, Arianna; Pisanu, Claudia; Micheletto, Laura; Bocchetta, Alberto; Del Zompo, Maria; Stochino, Maria Erminia
2017-06-01
We investigated a pulmonary adverse drug reaction possibly induced by fluoxetine, the Interstitial Lung Disease, by performing a systematic review of published case reports on this subject, a review of the World Health Organization VigiAccess database, of the European EudraVigilance database and of a national Pharmacovigilance database (Italian Pharmacovigilance Network). The research found a total of seven cases linking fluoxetine to Interstitial Lung Disease in the literature. 36 cases of interstitial lung disease related to fluoxetine were retrieved from the VigiAccess database (updated to July 2016), and 36 reports were found in EudraVigilance database (updated to June 2016). In the Italian Pharmacovigilance database (updated to August 2016), we found only one case of Interstitial Lung Disease, codified as "pulmonary disease". Our investigation shows that fluoxetine might be considered as a possible cause of Interstitial Lung Disease. In particular, although here we do not discuss the assessment of benefits and harms of fluoxetine, since this antidepressant is widely used, our review suggests that fluoxetine-induced Interstitial Lung Disease should be considered in patients with dyspnea, associated or not with dry cough, who are treated with this drug. An early withdrawn of fluoxetine could be useful to obtain a complete remission of this adverse drug reaction and special attention should be particularly devoted to long-term therapy, and to female and elderly patients. Although the spontaneous reporting system is affected by important limitations, drug post- marketing surveillance represents an important tool to evaluate the real world effectiveness and safety of drugs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Parra, Edwin Roger; Ruppert, Aline Domingos Pinto; Capelozzi, Vera Luiza
2014-01-01
To validate the importance of the angiotensin II receptor isotypes and the lymphatic vessels in systemic sclerosis and idiopathic pulmonary fibrosis. We examined angiotensin II type 1 and 2 receptors and lymphatic vessels in the pulmonary tissues obtained from open lung biopsies of 30 patients with systemic sclerosis and 28 patients with idiopathic pulmonary fibrosis. Their histologic patterns included cellular and fibrotic non-specific interstitial pneumonia for systemic sclerosis and usual interstitial pneumonia for idiopathic pulmonary fibrosis. We used immunohistochemistry and histomorphometry to evaluate the number of cells in the alveolar septae and the vessels stained by these markers. Survival curves were also used. We found a significantly increased percentage of septal and vessel cells immunostained for the angiotensin type 1 and 2 receptors in the systemic sclerosis and idiopathic pulmonary fibrosis patients compared with the controls. A similar percentage of angiotensin 2 receptor positive vessel cells was observed in fibrotic non-specific interstitial pneumonia and usual interstitial pneumonia. A significantly increased percentage of lymphatic vessels was present in the usual interstitial pneumonia group compared with the non-specific interstitial pneumonia and control groups. A Cox regression analysis showed a high risk of death for the patients with usual interstitial pneumonia and a high percentage of vessel cells immunostained for the angiotensin 2 receptor in the lymphatic vessels. We concluded that angiotensin II receptor expression in the lung parenchyma can potentially control organ remodeling and fibrosis, which suggests that strategies aimed at preventing high angiotensin 2 receptor expression may be used as potential therapeutic target in patients with pulmonary systemic sclerosis and idiopathic pulmonary fibrosis.
Advances in the treatment of rheumatic interstitial lung disease.
Vassallo, Robert; Thomas, Charles F
2004-05-01
Interstitial lung disease frequently complicates the rheumatic diseases. The purpose of this review is to outline recent advances and current concepts regarding the management of these interstitial lung diseases. Several histologic lesions cause interstitial lung disease in rheumatic diseases, including nonspecific interstitial pneumonia, usual interstitial pneumonia, organizing pneumonia, lymphocytic interstitial pneumonia, desquamative interstitial pneumonia, and acute interstitial pneumonia. Although the relative frequency of occurrence of these histopathologic lesions is not definitively established, it seems that nonspecific interstitial pneumonia accounts for a large proportion of rheumatic disease-associated interstitial lung diseases. Although usual interstitial pneumonia generally responds poorly to corticosteroid therapy, other forms of interstitial pneumonia are often steroid responsive and have a more favorable long-term prognosis. Pulmonary hypertension is increasingly recognized as a complication of these interstitial lung diseases. Treatment of pulmonary hypertension in these patients provides clinical benefit and may suppress pulmonary inflammation and fibrosis. Lung transplantation is a treatment option for selected patients with severe pulmonary involvement and limited life expectancy. Interstitial lung disease is common in the rheumatic diseases, may be caused by a variety of lesions that respond differently to treatment, and may lead to the development of pulmonary hypertension. Whether the prognosis of interstitial lung disease associated with rheumatic disease is similar to that associated with the idiopathic interstitial pneumonias is not known. Treatment of these interstitial lung diseases should take into account the specific histologic lesion, the activity of the underlying rheumatic disease, and associated pulmonary hypertension, if present. The diagnosis of a rheumatic disease is no longer an absolute contraindication to lung transplantation.
Bardoxolone Methyl Evaluation in Patients With Pulmonary Hypertension (PH) - LARIAT
2018-06-08
Pulmonary Arterial Hypertension; Pulmonary Hypertension; Interstitial Lung Disease; Idiopathic Interstitial Pneumonia; Idiopathic Pulmonary Fibrosis; Sarcoidosis; Respiratory Bronchiolitis Associated Interstitial Lung Disease; Desquamative Interstitial Pneumonia; Cryptogenic Organizing Pneumonia; Acute Interstitial Pneumonitis; Idiopathic Lymphoid Interstitial Pneumonia; Idiopathic Pleuroparenchymal Fibroelastosis
Liu, L J; Schlesinger, M
2015-09-07
A correct description of the hydraulic conductivity is essential for determining the actual tumor interstitial fluid pressure (TIFP) distribution. Traditionally, it has been assumed that the hydraulic conductivities both in a tumor and normal tissue are constant, and that a tumor has a much larger interstitial hydraulic conductivity than normal tissue. The abrupt transition of the hydraulic conductivity at the tumor surface leads to non-physical results (the hydraulic conductivity and the slope of the TIFP are not continuous at tumor surface). For the sake of simplicity and the need to represent reality, we focus our analysis on avascular or poorly vascularized tumors, which have a necrosis that is mostly in the center and vascularization that is mostly on the periphery. We suggest that there is an intermediary region between the tumor surface and normal tissue. Through this region, the interstitium (including the structure and composition of solid components and interstitial fluid) transitions from tumor to normal tissue. This process also causes the hydraulic conductivity to do the same. We introduce a continuous variation of the hydraulic conductivity, and show that the interstitial hydraulic conductivity in the intermediary region should be monotonically increasing up to the value of hydraulic conductivity in the normal tissue in order for the model to correspond to the actual TIFP distribution. The value of the hydraulic conductivity at the tumor surface should be the lowest in value. Copyright © 2015 Elsevier Ltd. All rights reserved.
Laser bioengineering of glass-titanium implants surface
NASA Astrophysics Data System (ADS)
Lusquiños, F.; Arias-González, F.; Penide, J.; del Val, J.; Comesaña, R.; Quintero, F.; Riveiro, A.; Boutinguiza, M.; Pascual, M. J.; Durán, A.; Pou, J.
2013-11-01
Osseointegration is the mean challenge when surgical treatments fight against load-bearing bone diseases. Absolute bone replacement by a synthetic implant has to be completed not only from the mechanics point of view, but also from a biological approach. Suitable strength, resilience and stress distribution of titanium alloy implants are spoiled by the lack of optimal biological characteristics. The inert quality of extra low interstitial titanium alloy, which make it the most attractive metallic alloy for biomedical applications, oppose to an ideal surface with bone cell affinity, and capable to stimulate bone attachment bone growth. Diverse laser treatments have been proven as effective tools to modify surface properties, such as wettability in contact to physiological fluids, or osteoblast guided and slightly enhanced attachment. The laser surface cladding can go beyond by providing titanium alloy surfaces with osteoconduction and osteoinduction properties. In this research work, the laser radiation is used to produce bioactive glass coatings on Ti6Al4V alloy substrates. Specific silicate bioactive glass compositions has been investigated to achieve suitable surface tension and viscosity temperature behavior during processing, and to provide with the required release of bone growth gene up regulation agents in the course of resorption mediated by physiological fluids. The produced coatings and interfaces, the surface osteoconduction properties, and the chemical species release in simulated physiological fluid were characterized by scanning electron microscopy (SEM), hot stage microscopy (HSM), X-ray diffraction (XRD), X ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR).
Impurity and defect interactions during laser thermal annealing in Ge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milazzo, R., E-mail: ruggero.milazzo@unipd.it; De Salvador, D.; Carnera, A.
2016-01-28
The microscopic mechanisms involving dopants, contaminants, and defects in Ge during pulsed melting laser thermal annealing (LTA) are investigated in detail. Samples both un-implanted and implanted with As or B are processed by LTA as well as characterized in terms of chemical (1D and 3D), electrical, and strain profiling. The clustering of As is directly measured by 3D chemical profiling and correlated with its partial electrical activation along with a reduction of the lattice strain induced by As atoms. A semi-quantitative microscopic model involving the interaction with mobile As-vacancy (AsV) complexes is proposed to describe the clustering mechanism. Boron ismore » shown to follow different clustering behavior that changes with depth and marked by completely different strain levels. Oxygen penetrates from the surface into all the samples as a result of LTA and, only in un-implanted Ge, it occupies an interstitial position inducing also positive strain in the lattice. On the contrary, data suggest that the presence of As or B forces O to assume different configurations with negligible strain, through O-V or O-B interactions for the two dopant species, respectively. These data suggest that LTA does not inject a significant amount of vacancies in Ge, at variance with Si, unless As atoms or possibly other n-type dopants are present. These results have to be carefully considered for modeling the LTA process in Ge and its implementation in technology.« less
Malheiro, Vera N; Spear, Rose L; Brooks, Roger A; Markaki, Athina E
2011-10-01
The rationale behind this work is to design an implant device, based on a ferromagnetic material, with the potential to deform in vivo promoting osseointegration through the growth of a healthy periprosthetic bone structure. One of the primary requirements for such a device is that the material should be non-inflammatory and non-cytotoxic. In the study described here, we assessed the short-term cellular response to 444 ferritic stainless steel; a steel, with a very low interstitial content and a small amount of strong carbide-forming elements to enhance intergranular corrosion resistance. Two different human cell types were used: (i) foetal osteoblasts and (ii) monocytes. Austenitic stainless steel 316L, currently utilised in many commercially available implant designs, and tissue culture plastic were used as the control surfaces. Cell viability, proliferation and alkaline phosphatase activity were measured. In addition, cells were stained with alizarin red and fluorescently-labelled phalloidin and examined using light, fluorescence and scanning electron microscopy. Results showed that the osteoblast cells exhibited a very similar degree of attachment, growth and osteogenic differentiation on all surfaces. Measurement of lactate dehydrogenase activity and tumour necrosis factor alpha protein released from human monocytes indicated that 444 stainless steel did not cause cytotoxic effects or any significant inflammatory response. Collectively, the results suggest that 444 ferritic stainless steel has the potential to be used in advanced bone implant designs. Copyright © 2011 Elsevier Ltd. All rights reserved.
Thermal properties of capacitively coupled electrodes in interstitial hyperthermia.
van der Koijk, J F; Crezee, J; Lagendijk, J J
1998-01-01
The multi-electrode current source (MECS) interstitial hyperthermia system which is used for treatment of cancer, employs segmented electrodes inserted in plastic tubes implanted in the treatment volume. The mean power deposition of the individual electrodes is controlled by varying the duty cycle of the RF signal applied to the electrodes, using thermocouples inside the electrodes for thermometry. A non-zero loss angle results in self-heating of the catheter. The thermal influence of self-heating was investigated and an analysis of the measurement of temperatures inside the catheter during and after heating is presented. Analytical models and a high-resolution numerical model were used for the calculation of steady state and transient distributions, respectively. The model results are compared with experimental data obtained in a muscle equivalent phantom. Results indicate that there is no difference between temperature inside and outside the catheter when using lossless catheter materials (e.g. PE and PTFE). Self-heating in the catheter wall has an adverse effect on the uniformity of the stationary temperature distribution and the reliability of temperature measurement with internal thermometry. These problems remain within acceptable limits for mildly lossy materials; the difference between the temperature inside and outside is only 6% when using low-loss Nylon. Analysis of the thermal decay after power-off shows that low-loss materials allow more time to obtain an accurate estimate of the tissue temperature at the catheter wall during power-on. This effect is enhanced by the presence of minute air layers in the applicator. Distortion of temperature gradients along the catheter was also investigated. Key factors are the thermal conduction across the catheter wall, and especially the presence of minute layers of air between consecutive layers of the probe. The distortion extends less than two millimetres, which is acceptable. The simulation results are compatible with measurements in phantoms and show that, if the proper choice of materials is made, the MECS applicator answers our expectations and that the temperature measurement inside the catheter can be used for direct feedback treatment control.
Hydrogen-enhanced clusterization of intrinsic defects and impurities in silicon
NASA Astrophysics Data System (ADS)
Mukashev, B. N.; Abdullin, Kh. A.; Gorelkinskii, Yu. V.; Tamendarov, M. F.; Tokmoldin, S. Zh
2001-01-01
Formation of intrinsic and impurity defect complexes in hydrogenated monocrystalline silicon is studied. Hydrogen was incorporated into samples by different ways: either by proton implantation at 80 and 300 K, or by annealing at 1250°C for 30-60 min in a sealed quartz ampoule containing ∼10 -3 ml of distilled water, or by treatment in hydrogen plasma. Radiation defects were incorporated either during the hydrogen implantation or by additional irradiation with protons or α-particles. The measurements were performed by electron paramagnetic resonance (EPR), deep level transient spectroscopy (DLTS) and infrared absorption (IR) methods. Essential differences of defect formation processes in hydrogenated samples as compared with reference samples were detected. The main reasons responsible for the differences are (i) hydrogen precipitation in a supersaturated solution during thermal treatment; (ii) interaction of hydrogen with defects and impurities and hydrogen-induced formation of defects; (iii) ability of hydrogen to play the role of accelerator of impurities precipitation. These factors result in the formation of vacancy-related, interstitial-related and impurity clusters which are observed only in the presence of hydrogen. The nature of the clusters and possible models of their structure are discussed.
Durability Assessment of TiAl Alloys
NASA Technical Reports Server (NTRS)
Draper, Susan L.; Lerch, Bradley A.
2008-01-01
The durability of TiAl is a prime concern for the implementation of TiAl into aerospace engines. Two durability issues, the effect of high temperature exposure on mechanical properties and impact resistance, have been investigated and the results are summarized in this paper. Exposure to elevated temperatures has been shown to be detrimental to the room temperature ductility of gamma alloys with the most likely mechanisms being the ingress of interstitials from the surface. Fluorine ion implantation has been shown to improve the oxidation resistance of gamma alloys, and ideally it could also improve the environmental embrittlement of high Nb content TiAl alloys. The effect of F ion implantation on the surface oxidation and embrittlement of a third generation, high Nb content TiAl alloy (Ti-45Al-5Nb-B-C) were investigated. Additionally, the ballistic impact resistance of a variety of gamma alloys, including Ti-48Al-2Cr- 2Nb, Ti-47Al-2Cr-2Nb, ABB-2, ABB-23, NCG359E, 95A and Ti-45Al-5Nb-B-C was accessed. Differences in the ballistic impact properties of the various alloys will be discussed, particularly with respect to their manufacturing process, microstructure, and tensile properties.
NASA Technical Reports Server (NTRS)
Uchida, Hinako; Righter, Kevin; Lavina, Barbara; Nowell, Matthew M.; Wright, Stuart I.; Downs, Robert T.; Yang, Hexiong
2007-01-01
A magnesium vanadate spinel crystal, ideally MgV2O4, synthesized at 1 bar, 1200 C and equilibrated under FMQ + 1.3 log f(sub o2) condition, was investigated using single-crystal X-ray diffraction, electron microprobe, and electron backscatter (EBSD). The initial X-ray structure refinements gave tetrahedral and octahedral site occupancies, along with the presence of 0.053 apfu Mg at an interstitial octahedral site . Back-scattered electron (BSE) images and electron microprobe analyses revealed the existence of an Mg-rich phase in the spinel matrix, which was too small (less than or equal to 3microns) for an accurate chemical determination. The EBSD analysis combined with X-ray energy dispersive spectroscop[y (XEDS) suggested that the Mg-rich inclusions are periclase oriented coherently with the spinel matrix. The final structure refinements were optimized by subtracting the X-ray intensity contributions (approx. 9%) of periclase reflections, which eliminated the interstitial Mg. This study provides insight into possible origins of refined interstitial cations reported in the the literature for spinel, and points to the difficulty of using only X-ray diffraction data to distinguish a spinel with interstitial cations from one with coherently oriented MgO inclusions.
Radioactive seed migration following parotid gland interstitial brachytherapy.
Fan, Yi; Huang, Ming-Wei; Zhao, Yi-Jiao; Gao, Hong; Zhang, Jian-Guo
To evaluate the incidence and associated factors of pulmonary seed migration after parotid brachytherapy using a novel migrated seed detection technique. Patients diagnosed with parotid cancer who underwent permanent parotid brachytherapy from January 2006 to December 2011 were reviewed retrospectively. Head and neck CT scans and chest X-rays were evaluated during routine follow-up. Mimics software and Geomagic Studio software were used for seed reconstruction and migrated seed detection from the original implanted region, respectively. Postimplant dosimetry analysis was performed after seeds migration if the seeds were still in their emitting count. Adverse clinical sequelae from seed embolization to the lung were documented. The radioactive seed implants were identified on chest X-rays in 6 patients. The incidence rate of seed migration in 321 parotid brachytherapy patients was 1.87% (6/321) and that of individual seed migration was 0.04% (6/15218 seeds). All migrated seeds were originally from the retromandibular region. No adverse dosimetric consequences were found in the target region. Pulmonary symptoms were not reported by any patient in this study. In our patient set, migration of radioactive seeds with an initial radioactivity of 0.6-0.7 mCi to the chest following parotid brachytherapy was rare. Late migration of a single seed from the central target region did not affect the dosimetry significantly, and patients did not have severe short-term complications. This study proposed a novel technique to localize the anatomical origin of the migrated seeds during brachytherapy. Our evidence suggested that placement of seeds adjacent to blood vessels was associated with an increased likelihood of seed migration to the lungs. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Does sex matter? A matched pairs analysis of neuromodulation outcomes in women and men.
Nguyen, Laura N; Bartley, Jamie; Killinger, Kim A; Gupta, Priyanka; Lavin, John; Khourdaji, Ayad; Gilleran, Jason; Gaines, Natalie; Boura, Judith A; Peters, Kenneth M
2018-05-01
To evaluate whether baseline symptoms and outcomes are influenced by gender in a matched cohort undergoing neuromodulation. Patients in our prospective neuromodulation database that had a tined lead placed were reviewed. Those that had implantable pulse generator (IPG) placed were matched on age and urologic diagnosis. History, voiding diaries, satisfaction, Interstitial Cystitis Symptom/Problem Index (ICSIPI), and overactive bladder symptom severity (OABq ss)/health-related quality of life (HRQOL) preimplant and over 3 years were evaluated using descriptive statistics, repeated measures, and matched pair GEE or mixed analyses. Of 590 patients in the database, more women than men received an IPG (450/488; 92.2 vs. 84/102; 82.4%; p = 0.0011). Eighty matched pairs (n = 160; 81% ≥ 50 years old; 56.25% had urgency/frequency with urge incontinence-UI) were identified and evaluated. On voiding diaries, volume/void was greater in women only at baseline (p = 0.040); both groups improved over time (p < 0.0001). Urinary frequency improved in both women and men (p = 0.0010; p = 0.0025). Over 3 years, UI episodes/day improved only in men (p = 0.017) and UI severity improved only in women (p < 0.0001). ICSIPI, OABq ss, and HRQOL scores improved similarly in both groups (p < 0.0001 for all measures in both groups), and although more women were satisfied at 3 months (p = 0.027), groups did not differ at other time points. More women undergo neuromodulation and have initial success and subsequent IPG implantation. UI episodes improved only in men, and UI severity improved only in women. Both women and men experienced similar levels of symptom improvement on other measures.
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.
Podder, Tarun K; Beaulieu, Luc; Caldwell, Barrett; Cormack, Robert A; Crass, Jostin B; Dicker, Adam P; Fenster, Aaron; Fichtinger, Gabor; Meltsner, Michael A; Moerland, Marinus A; Nath, Ravinder; Rivard, Mark J; Salcudean, Tim; Song, Danny Y; Thomadsen, Bruce R; Yu, Yan
2014-10-01
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the applications of this technology have been in the implantation of seeds in patients with early-stage prostate cancer. Nevertheless, the techniques apply to any clinical site where interstitial brachytherapy is appropriate. In consideration of the rapid developments in this area, the American Association of Physicists in Medicine (AAPM) commissioned Task Group 192 to review the state-of-the-art in the field of robotic interstitial brachytherapy. This is a joint Task Group with the Groupe Européen de Curiethérapie-European Society for Radiotherapy & Oncology (GEC-ESTRO). All developed and reported robotic brachytherapy systems were reviewed. Commissioning and quality assurance procedures for the safe and consistent use of these systems are also provided. Manual seed placement techniques with a rigid template have an estimated in vivo accuracy of 3-6 mm. In addition to the placement accuracy, factors such as tissue deformation, needle deviation, and edema may result in a delivered dose distribution that differs from the preimplant or intraoperative plan. However, real-time needle tracking and seed identification for dynamic updating of dosimetry may improve the quality of seed implantation. The AAPM and GEC-ESTRO recommend that robotic systems should demonstrate a spatial accuracy of seed placement ≤1.0 mm in a phantom. This recommendation is based on the current performance of existing robotic brachytherapy systems and propagation of uncertainties. During clinical commissioning, tests should be conducted to ensure that this level of accuracy is achieved. These tests should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot-clinician and robot-patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.
Novel doping alternatives for single-layer transition metal dichalcogenides
NASA Astrophysics Data System (ADS)
Onofrio, Nicolas; Guzman, David; Strachan, Alejandro
2017-11-01
Successful doping of single-layer transition metal dichalcogenides (TMDs) remains a formidable barrier to their incorporation into a range of technologies. We use density functional theory to study doping of molybdenum and tungsten dichalcogenides with a large fraction of the periodic table. An automated analysis of the energetics, atomic and electronic structure of thousands of calculations results in insightful trends across the periodic table and points out promising dopants to be pursued experimentally. Beyond previously studied cases, our predictions suggest promising substitutional dopants that result in p-type transport and reveal interesting physics behind the substitution of the metal site. Doping with early transition metals (TMs) leads to tensile strain and a significant reduction in the bandgap. The bandgap increases and strain is reduced as the d-states are filled into the mid TMs; these trends reverse as we move into the late TMs. Additionally, the Fermi energy increases monotonously as the d-shell is filled from the early to mid TMs and we observe few to no gap states, indicating the possibility of both p- (early TMs) and n- (mid TMs) type doping. Quite surprisingly, the simulations indicate the possibility of interstitial doping of TMDs; the energetics reveal that a significant number of dopants, increasing in number from molybdenum disulfide to diselenide and to ditelluride, favor the interstitial sites over adsorbed ones. Furthermore, calculations of the activation energy associated with capturing the dopants into the interstitial site indicate that the process is kinetically possible. This suggests that interstitial impurities in TMDs are more common than thought to date and we propose a series of potential interstitial dopants for TMDs relevant for application in nanoelectronics based on a detailed analysis of the predicted electronic structures.
Exploring the use of environmental DNA to determine the species of salmon redds
Strobel, Burke; Laramie, Matthew; Pilliod, David S.
2017-01-01
Annual redd counts are used to monitor the status and trends of salmonid populations, but methods to easily and reliably determine which of sympatric species made specific redds are lacking. We explored whether environmental DNA (eDNA) analysis might prove useful for determining the species of salmon redds. We collected eDNA samples from the interstitial spaces of redds of Chinook Salmon Oncorhynchus tshawytscha, redds of Coho Salmon O. kisutch, and areas of undisturbed gravel (n = 10, each), as well as from the water column adjacent to each of those sites in the Sandy River basin, Oregon, USA during the fall of 2013. The concentrations of Chinook and Coho eDNA were quantified within each sample using real-time PCR. The water in the interstitial spaces of redds contained significantly higher eDNA concentrations of the species that made the redd than (1) the other species and (2) the adjacent water column. In contrast, neither Chinook nor Coho eDNA was significantly more concentrated than the other in the water from the interstitial spaces of undisturbed gravel. The interstitial water of undisturbed gravel contained significantly higher eDNA concentrations of Coho than the adjacent water column. In contrast, Chinook eDNA concentration was similar in the interstitial water of undisturbed gravel and the adjacent water column. Both species’ redds had significantly higher concentrations of their respective species’ eDNA than did undisturbed gravel, but conclusions were confounded by differences in the timing and locations of sampling. This initial investigation highlights the potential value and some of the complexity of using eDNA analysis to indicate redd species.
Chowdhary, Ramesh; Halldin, Anders; Jimbo, Ryo; Wennerberg, Ann
2015-06-01
To describe the early bone tissue response to implants with and without micro threads designed to the full length of an oxidized titanium implant. A pair of two-dimensional finite element models was designed using a computer aided three-dimensional interactive application files of an implant model with micro threads in between macro threads and one without micro threads. Oxidized titanium implants with (test implants n=20) and without (control implants n=20) micro thread were prepared. A total of 12 rabbits were used and each received four implants. Insertion torque while implant placement and removal torque analysis after 4 weeks was performed in nine rabbits, and histomorphometric analysis in three rabbits, respectively. Finite element analysis showed less stress accumulation in test implant models with 31Mpa when compared with 62.2 Mpa in control implant model. Insertion and removal torque analysis did not show any statistical significance between the two implant designs. At 4 weeks, there was a significant difference between the two groups in the percentage of new bone volume and bone-to-implant contact in the femur (p< .05); however, not in the tibia. The effect of micro threads was prominent in the femur suggesting that micro threads promote bone formation. The stress distribution supported by the micro threads was especially effective in the cancellous bone. © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Scott, Serena J.; Salgaonkar, Vasant; Prakash, Punit; Burdette, E. Clif; Diederich, Chris J.
2017-03-01
Preferential acoustic absorption and heating of bone can significantly impact interstitial ultrasound ablation of tumors within or bordering the spine. Furthermore, intervening cortical bone may provide acoustic and thermal insulation that can protect sensitive structures nearby, such as the spinal cord. The objectives of this study are firstly, to apply parametric and patient-specific models to theoretically assess the feasibility of interstitial ultrasound ablation of tumors within and near the spine, and secondly, to identify potential energy delivery strategies, safety criteria, advantages, and disadvantages of interstitial ultrasound in this setting. Transient biothermal models using previously validated approximations for power deposition within bone from interstitial sources were employed. Multilayered axisymmetric models were used to perform a parametric assessment of the impact of tumor dimensions, attenuation (dependent on residual bone content), perfusion, and maximum temperature thresholds on necessary treatment parameters and on treatment effectiveness. 3D patient-specific finite element models were generated based on segmented CT scans for nine representative patient cases selected to bracket a range of clinical interest, with tumors in or near the vertebrae, sacrum, and ilium. Tumors were 10-27 mm in diameter, 10-43 mm long, and 0-14 mm from the spinal canal. Paraspinal tumors, osteolytic vertebral tumors, and a mixed osteolytic/osteoblastic iliac bone tumor were considered. 7 MHz (1.5 mm OD) and 3.0 MHz (3.2 mm OD) applicators with an array of 1-4 tubular transducers (0.5 -1.5 cm long, 150-360° sector angles), were applied in various implant configurations. Variable thicknesses of bone insulating critical anatomy from the tumor and insulation of the spinal cord with injected carbon dioxide were also investigated for definition of safety margins and possible protection of critical structures. 6-44 mm diameter osteolytic tumors surrounded by bone and blastic (high bone content) lesions up to 20 mm in diameter could be fully ablated by 7 MHz interstitial ultrasound using 120-5,900 J and treatment durations of 0.4-15 min. 100% of the volumes of five simulated tumors located 4.3-14 mm from the spinal canal and 94.6-99.9% of the volumes of four simulated tumors 0-4.5 mm from the spinal canal were ablated (>240 EM43°C) within 15 min without damaging (<6 EM43°C) critical nerves. Preferential ultrasound absorption and concomitant heating at bone surfaces allowed for faster, more effective ablations with less delivered energy. 3-5 mm of normal cortical bone was found to provide a safety margin and reduce temperature elevations in untargeted tissues. Critical anatomy less than 3-5 mm from a tumor encapsulated by bone could be preserved by reducing the acoustic energy aimed towards these structures and/or through injection of insulating CO2. Parametric and patient-specific studies demonstrated the feasibility of interstitial ultrasound ablation of paraspinal tumors and osteolytic tumors within the spine. Preferential absorption of ultrasound by bone may provide improved localization, faster treatment times, and larger treatment zones in highly osteolytic and soft tissue tumors in and near bone compared to other heating modalities. This work was supported by the NIH grant R44CA112852.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohori, N.P.; Sciurba, F.C.; Owens, G.R.
We report four cases of giant-cell interstitial pneumonia that occurred in association with exposure to hard metals. All patients presented with chronic interstitial lung disease and had open-lung biopsies that revealed marked interstitial fibrosis, cellular interstitial infiltrates, and prominent intraalveolar macrophages as well as giant cells displaying cellular cannibalism. We also review the literature to determine the sensitivity and specificity of giant-cell interstitial pneumonia for hard-metal pneumoconiosis. Although hard-metal pneumoconiosis may take the form of usual interstitial pneumonia, desquamative interstitial pneumonia, and giant-cell interstitial pneumonia, the finding of giant-cell interstitial pneumonia is almost pathognomonic of hard-metal disease and should provokemore » an investigation of occupational exposure. 25 references.« less
Paulin, Francisco; Doyle, Tracy J; Fletcher, Elaine A; Ascherman, Dana P; Rosas, Ivan O
2015-01-01
The prevalence of clinically evident interstitial lung disease in patients with rheumatoid arthritis is approximately 10%. An additional 33% of undiagnosed patients have interstitial lung abnormalities that can be detected with high-resolution computed tomography. Rheumatoid arthritis-interstitial lung disease patients have three times the risk of death compared to those with rheumatoid arthritis occurring in the absence of interstitial lung disease, and the mortality related to interstitial lung disease is rising. Rheumatoid arthritis-interstitial lung disease is most commonly classified as the usual interstitial pneumonia pattern, overlapping mechanistically and phenotypically with idiopathic pulmonary fibrosis, but can occur in a non-usual interstitial pneumonia pattern, mainly nonspecific interstitial pneumonia. Based on this, we propose two possible pathways to explain the coexistence of rheumatoid arthritis and interstitial lung disease: (i) Rheumatoid arthritis-interstitial lung disease with a non-usual interstitial pneumonia pattern may come about when an immune response against citrullinated peptides taking place in another site (e.g. the joints) subsequently affects the lungs; (ii) Rheumatoid arthritis-interstitial lung disease with a usual interstitial pneumonia pattern may represent a disease process in which idiopathic pulmonary fibrosis-like pathology triggers an immune response against citrullinated proteins that promotes articular disease indicative of rheumatoid arthritis. More studies focused on elucidating the basic mechanisms leading to different sub-phenotypes of rheumatoid arthritis-interstitial lung disease and the overlap with idiopathic pulmonary fibrosis are necessary to improve our understanding of the disease process and to define new therapeutic targets.
Yoshida, Ken; Yamazaki, Hideya; Takenaka, Tadashi; Kotsuma, Tadayuki; Yoshida, Mineo; Furuya, Seiichi; Tanaka, Eiichi; Uegaki, Tadaaki; Kuriyama, Keiko; Matsumoto, Hisanobu; Yamada, Shigetoshi; Ban, Chiaki
2010-07-01
To investigate the feasibility of our novel image-based high-dose-rate interstitial brachytherapy (HDR-ISBT) for uterine cervical cancer, we evaluated the dose-volume histogram (DVH) according to the recommendations of the Gynecological GEC-ESTRO Working Group for image-based intracavitary brachytherapy (ICBT). Between June 2005 and June 2007, 18 previously untreated cervical cancer patients were enrolled. We implanted magnetic resonance imaging (MRI)-available plastic applicators by our unique ambulatory technique. Total treatment doses were 30-36 Gy (6 Gy per fraction) combined with external beam radiotherapy (EBRT). Treatment plans were created based on planning computed tomography with MRI as a reference. DVHs of the high-risk clinical target volume (HR CTV), intermediate-risk CTV (IR CTV), and the bladder and rectum were calculated. Dose values were biologically normalized to equivalent doses in 2-Gy fractions (EQD(2)). The median D90 (HR CTV) and D90 (IR CTV) per fraction were 6.8 Gy (range, 5.5-7.5) and 5.4 Gy (range, 4.2-6.3), respectively. The median V100 (HR CTV) and V100 (IR CTV) were 98.4% (range, 83-100) and 81.8% (range, 64-93.8), respectively. When the dose of EBRT was added, the median D90 and D100 of HR CTV were 80.6 Gy (range, 65.5-96.6) and 62.4 Gy (range, 49-83.2). The D(2cc) of the bladder was 62 Gy (range, 51.4-89) and of the rectum was 65.9 Gy (range, 48.9-76). Although the targets were advanced and difficult to treat effectively by ICBT, MRI-aided image-based ISBT showed favorable results for CTV and organs at risk compared with previously reported image-based ICBT results. (c) 2010 Elsevier Inc. All rights reserved.
Funamori, Nobumasa; Kojima, Kenji M.; Wakabayashi, Daisuke; Sato, Tomoko; Taniguchi, Takashi; Nishiyama, Norimasa; Irifune, Tetsuo; Tomono, Dai; Matsuzaki, Teiichiro; Miyazaki, Masanori; Hiraishi, Masatoshi; Koda, Akihiro; Kadono, Ryosuke
2015-01-01
Hydrogen in the Earth's deep interior has been thought to exist as a hydroxyl group in high-pressure minerals. We present Muon Spin Rotation experiments on SiO2 stishovite, which is an archetypal high-pressure mineral. Positive muon (which can be considered as a light isotope of proton) implanted in stishovite was found to capture electron to form muonium (corresponding to neutral hydrogen). The hyperfine-coupling parameter and the relaxation rate of spin polarization of muonium in stishovite were measured to be very large, suggesting that muonium is squeezed in small and anisotropic interstitial voids without binding to silicon or oxygen. These results imply that hydrogen may also exist in the form of neutral atomic hydrogen in the deep mantle. PMID:25675890
Intrauterine adhesions as a risk factor for failed first-trimester pregnancy termination.
Luk, Janelle; Allen, Rebecca H; Schantz-Dunn, Julianna; Goldberg, Alisa B
2007-10-01
Risk factors for failed first-trimester surgical abortion include endometrial distortion caused by leiomyomas, uterine anomalies and malposition and cervical stenosis. This report introduces intrauterine adhesions as an additional risk factor. A multiparous woman presented for pregnancy termination at 6 weeks' gestation. Three suction-curettage attempts failed to remove what appeared to be an intrauterine pregnancy. Rising beta-hCG levels and concern for an interstitial ectopic pregnancy prompted a diagnostic laparoscopy and exploratory laparotomy without the identification of an ectopic pregnancy. After methotrexate treatment failed, the patient underwent ultrasound-guided hysteroscopy and suction curettage using a cannula with a whistle-cut aperture for the successful removal of a pregnancy implanted behind intrauterine adhesions. Intrauterine adhesions are a cause of failed surgical abortion. Ultrasound-guided hysteroscopy may be required for diagnosis.
NASA Astrophysics Data System (ADS)
Funamori, Nobumasa; Kojima, Kenji M.; Wakabayashi, Daisuke; Sato, Tomoko; Taniguchi, Takashi; Nishiyama, Norimasa; Irifune, Tetsuo; Tomono, Dai; Matsuzaki, Teiichiro; Miyazaki, Masanori; Hiraishi, Masatoshi; Koda, Akihiro; Kadono, Ryosuke
2015-02-01
Hydrogen in the Earth's deep interior has been thought to exist as a hydroxyl group in high-pressure minerals. We present Muon Spin Rotation experiments on SiO2 stishovite, which is an archetypal high-pressure mineral. Positive muon (which can be considered as a light isotope of proton) implanted in stishovite was found to capture electron to form muonium (corresponding to neutral hydrogen). The hyperfine-coupling parameter and the relaxation rate of spin polarization of muonium in stishovite were measured to be very large, suggesting that muonium is squeezed in small and anisotropic interstitial voids without binding to silicon or oxygen. These results imply that hydrogen may also exist in the form of neutral atomic hydrogen in the deep mantle.
NASA Astrophysics Data System (ADS)
Kallis, Karoline; Kreppner, Stephan; Lotter, Michael; Fietkau, Rainer; Strnad, Vratislav; Bert, Christoph
2018-05-01
Multi-catheter interstitial brachytherapy (iBT) is a treatment option for breast cancer patients after breast conserving surgery. Typically, only a few additional quality interventions after the first irradiation have been introduced to ensure the planned treatment delivery. Therefore, the purpose of this study is to show the possibilities of an electromagnetic tracking (EMT) system integrated into the afterloader for quality assurance (QA) in high-dose rate (HDR) iBT of patients with breast cancer. The hybrid afterloader system equipped with an electromagnetic sensor was used for all phantom and patient measurements. Phantom measurements were conducted to estimate the quality of different evaluation schemes. After a coherent point drift registration of the EMT traces to the reconstructed catheters based on computed tomograms the dwell positions (DP) were defined. Different fitting and interpolation methods were analyzed for the reconstruction of DPs. All estimated DPs were compared to the DPs defined in treatment planning. Until now, the implant geometry of 20 patients treated with HDR brachytherapy was acquired and explored. Regarding the reconstruction techniques, both fitting and interpolation were able to detect manually introduced shifts and swaps. Nonetheless, interpolation showed superior results (RMSE = 1.27 mm), whereas fitting seemed to be more stable to distortion and motion. The EMT system proved to be beneficial for QA in brachytherapy and furthermore, clinical feasibility was proven.
McAllister, Tim A.; Ayroud, Mejid; Bray, Tammy M.; Yost, Garold S.
2006-01-01
Abstract Over a 3-y period, 906 000 cattle were monitored in 23 feedlots in southern Alberta for symptoms of acute interstitial pneumonia (AIP). Plasma, urine, and lung tissue were collected at slaughter from 299 animals clinically diagnosed with AIP and from 156 healthy penmates and analyzed for 3-methylindole (3MI) derivatives and reduced glutathione concentration. From each animal, the left lung was subsampled for histologic examination. Concentrations of glutathione in lung tissue were reduced (P < 0.001) in animals showing clinical symptoms of AIP as compared with their asymptomatic penmates. Animals histologically confirmed as having AIP had higher levels of 3MI protein adducts in blood and lung tissue (P < 0.05) than did emergency-slaughtered animals without AIP. Within feedlots, where pens of heifers were fed either a standard dosage of melengestrol acetate (MGA) or none, the rate of death attributable to AIP was similar between treatment groups, but emergency slaughter after clinical diagnosis of AIP was done 3.2 times more often (P < 0.001) in the MGA-fed heifers than in the group not fed MGA. Use of MGA did not influence glutathione concentration. As growth performance of heifers given steroidal implants may not be improved by feeding MGA, the most cost-effective method of reducing the incidence of AIP-related emergency slaughter in feedlot heifers may be to eliminate MGA from the diet. PMID:16850945
Electric field-mediated transport of plasmid DNA in tumor interstitium in vivo.
Henshaw, Joshua W; Zaharoff, David A; Mossop, Brian J; Yuan, Fan
2007-11-01
Local pulsed electric field application is a method for improving non-viral gene delivery. Mechanisms of the improvement include electroporation and electrophoresis. To understand how electrophoresis affects pDNA delivery in vivo, we quantified the magnitude of electric field-induced interstitial transport of pDNA in 4T1 and B16.F10 tumors implanted in mouse dorsal skin-fold chambers. Four different electric pulse sequences were used in this study, each consisted of 10 identical pulses that were 100 or 400 V/cm in strength and 20 or 50 ms in duration. The interval between consecutive pulses was 1 s. The largest distance of transport was obtained with the 400 V/cm and 50 ms pulse, and was 0.23 and 0.22 microm/pulse in 4T1 and B16.F10 tumors, respectively. There were no significant differences in transport distances between 4T1 and B16.F10 tumors. Results from in vivo mapping and numerical simulations revealed an approximately uniform intratumoral electric field that was predominantly in the direction of the applied field. The data in the study suggested that interstitial transport of pDNA induced by a sequence of ten electric pulses was ineffective for macroscopic delivery of genes in tumors. However, the induced transport was more efficient than passive diffusion.
Increased Risk of Interstitial Lung Disease in Children with a Single R288K Variant of ABCA3
Wittmann, Thomas; Frixel, Sabrina; Höppner, Stefanie; Schindlbeck, Ulrike; Schams, Andrea; Kappler, Matthias; Hegermann, Jan; Wrede, Christoph; Liebisch, Gerhard; Vierzig, Anne; Zacharasiewicz, Angela; Kopp, Matthias Volkmar; Poets, Christian F; Baden, Winfried; Hartl, Dominik; van Kaam, Anton H; Lohse, Peter; Aslanidis, Charalampos; Zarbock, Ralf; Griese, Matthias
2016-01-01
The ABCA3 gene encodes a lipid transporter in type II pneumocytes critical for survival and normal respiratory function. The frequent ABCA3 variant R288K increases the risk for neonatal respiratory distress syndrome among term and late preterm neonates, but its role in children’s interstitial lung disease has not been studied in detail. In a retrospective cohort study of 228 children with interstitial lung disease related to the alveolar surfactant system, the frequency of R288K was assessed and the phenotype of patients carrying a single R288K variant further characterized by clinical course, lung histology, computed tomography and bronchoalveolar lavage phosphatidylcholine PC 32:0. Cell lines stably transfected with ABCA3-R288K were analyzed for intracellular transcription, processing and targeting of the protein. ABCA3 function was assessed by detoxification assay of doxorubicin, and the induction and volume of lamellar bodies. We found nine children with interstitial lung disease carrying a heterozygous R288K variant, a frequency significantly higher than in the general Caucasian population. All identified patients had neonatal respiratory insufficiency, recovered and developed chronic interstitial lung disease with intermittent exacerbations during early childhood. In vitro analysis showed normal transcription, processing, and targeting of ABCA3-R288K, but impaired detoxification function and smaller lamellar bodies. We propose that the R288K variant can underlie interstitial lung disease in childhood due to reduced function of ABCA3, demonstrated by decelerated detoxification of doxorubicin, reduced PC 32:0 content and decreased lamellar body volume. PMID:26928390
Geng, Jie-jie; Zhang, Kui; Chen, Li-na; Miao, Jin-lin; Yao, Meng; Ren, Ying; Fu, Zhi-guang; Chen, Zhi-nan; Zhu, Ping
2014-09-01
Lung interstitial fibrosis is a chronic lung disease, and few effective therapies are available to halt or reverse the progression of the disease. In murine and human lung fibrosis, the expression of CD147 is increased. However, the role of CD147 in lung fibrosis has not been identified, and it remains to be determined whether lung fibrosis would be improved by decreasing the expression of CD147. A murine bleomycin-induced lung interstitial fibrosis model was used in the experiments, and HAb18 mAbs and CsA were administered during the induction of lung fibrosis. In our study, we found that the HAb18 mAbs markedly reduced the collagen score and down-regulated M1 macrophages and Th17 cells. In vitro, flow cytometry analysis showed that M1 macrophages induced higher Th17 differentiation than M2 macrophages. After treatment with HAb18 mAbs or after reducing the expression of CD147 by lentivirus interference in M1 macrophages, the level of Th17 cells were significantly inhibited. In conclusion, HAb18 mAbs or CsA treatment ameliorates lung interstitial fibrosis. CD147 promoted M1 macrophage and induced the differentiation of Th17 cells in lung interstitial fibrosis, perhaps by regulating some cytokines such as IL-6, IL-1β, IL-12 and IL-23. These results indicated that CD147 may play an important role in the development of lung interstitial fibrosis. Copyright © 2014 Elsevier B.V. All rights reserved.
Diffusion and interactions of interstitials in hard-sphere interstitial solid solutions
NASA Astrophysics Data System (ADS)
van der Meer, Berend; Lathouwers, Emma; Smallenburg, Frank; Filion, Laura
2017-12-01
Using computer simulations, we study the dynamics and interactions of interstitial particles in hard-sphere interstitial solid solutions. We calculate the free-energy barriers associated with their diffusion for a range of size ratios and densities. By applying classical transition state theory to these free-energy barriers, we predict the diffusion coefficients, which we find to be in good agreement with diffusion coefficients as measured using event-driven molecular dynamics simulations. These results highlight that transition state theory can capture the interstitial dynamics in the hard-sphere model system. Additionally, we quantify the interactions between the interstitials. We find that, apart from excluded volume interactions, the interstitial-interstitial interactions are almost ideal in our system. Lastly, we show that the interstitial diffusivity can be inferred from the large-particle fluctuations alone, thus providing an empirical relationship between the large-particle fluctuations and the interstitial diffusivity.
NASA Astrophysics Data System (ADS)
Ware, Steve William
Focally ablative therapy of cancer has gained significant interest recently. Improvements in diagnostic techniques have created possibilities for treatment which were once clinically unfeasible. Imaging must be capable of allowing accurate diagnosis, staging and planning upon initiation of therapy. Recent improvements in MRI and molecular imaging techniques have made it possible to accurately localize lesions and in so doing, improve the accuracy of proposed focal treatments. Using multimodality imaging it is now possible to target, plan and evaluate interstitial focal treatment using liposome encapsulated beta emitting radionuclides in a variety of cancer types. Since most absorbed dose is deposited early and heterogeneously in beta-radionuclide therapy, investigation of the resultant molecular and cellular events during this time is important for evaluating treatment efficacy. Additionally, investigating a multifocal entity such as prostate cancer is helpful for determining whether MRI is capable of discriminating the proper lesion for therapy. Correlation of MRI findings with histopathology can further improve the accuracy of interstitial focal radionuclide therapy by providing non-invasive surrogates for tissue compartment sizes. In the application of such therapies, compartmental sizes are known to heavily influence the distribution of injected agents. This has clear dosimetric implications with the potential to significantly alter the efficacy of treatment. The hypothesis of this project was that multimodality imaging with magnetic resonance imaging (MRI), autoradiography (AR), and single photon emission computed tomography (SPECT) could be used to target, plan, and evaluate interstitial focal therapy with non-sealed source, liposome-encapsulated 186Re beta emitting radionuclides. The specific aims of this project were to 1) Identify suitable targets for interstitial focal therapy. This was done by retrospectively analyzing MRI data to characterize the tumor microenvironment through correlation with in-plane compartmental sizes obtained from histopathology analysis of step-sectioned prostatectomy specimens; 2) Gauge the ability of a reader to plan an interstitial focal treatment using MRI. This was accomplished by objective measures of contrast and volume measurement with subjective reader analysis of tumor conspicuities; 3) Evaluation of the early biologic response to 186Re interstitial focal therapy. This was achieved by correlation of histochemistry (HC) markers: hetrochromatin protein alpha (HP1α), cluster of differentiation 34 (CD34), terminal deoxynucleotidal transferase nick end labeling (TUNEL), caspase 3, Ki-67 and hematoxylin & eosin (H&E) to the radiation distribution as seen on AR and radiation absorbed dose as computed from planar imaging. The conclusions of this study are that prostate MRI allows targeting of appropriate lesions for therapy by its ability to inform on the tumor microenvironment. MRI distinguishes prostatic tumors on the basis of tissue composition. Readers are better able reproduce volumes and thus plan interstitial therapy for tumors which have a denser, more homogeneous composition. The combination of SPECT and autoradiography showed a dose and position dependent expression of HC markers. These results demonstrate that multimodality imaging is capable of targeting, planning and evaluating interstitial focal therapy.
Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor
2010-07-01
To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.
Ion implantation of solar cell junctions without mass analysis
NASA Technical Reports Server (NTRS)
Fitzgerald, D.; Tonn, D. G.
1981-01-01
This paper is a summary of an investigation to determine the feasibility of producing solar cells by means of ion implantation without the use of mass analysis. Ion implants were performed using molecular and atomic phosphorus produced by the vaporization of solid red phosphorus and ionized in an electron bombardment source. Solar cell junctions were ion implanted by mass analysis of individual molecular species and by direct unanalyzed implants from the ion source. The implant dose ranged from 10 to the 14th to 10 to the 16th atoms/sq cm and the energy per implanted atom ranged from 5 KeV to 40 KeV in this study.
Hepel, Jaroslaw T; Arthur, Douglas; Shaitelman, Simona; Polgár, Csaba; Todor, Dorin; Zoberi, Imran; Kamrava, Mitchell; Major, Tibor; Yashar, Catheryn; Wazer, David E
To develop a consensus report for the quality practice of accelerated partial breast irradiation (APBI) using interstitial multicatheter brachytherapy (IMB). The American Brachytherapy Society Board appointed an expert panel with clinical and research experience with breast brachytherapy to provide guidance for the current practice of IMB. This report is based on a comprehensive literature review with emphasis on randomized data and expertise of the panel. Randomized trials have demonstrated equivalent efficacy of APBI using IMB compared with whole breast irradiation for select patients with early-stage breast cancer. Several techniques for placement of interstitial catheters are described, and importance of three-dimensional planning with appropriate optimization is reviewed. Optimal target definition is outlined. Commonly used dosing schemas include 50 Gy delivered in pulses of 0.6-0.8 Gy/h using pulsed-dose-rate technique and 34 Gy in 10 fractions, 32 Gy in eight fractions, or 30 Gy in seven fractions using high-dose-rate technique. Potential toxicities and strategies for toxicity avoidance are described in detail. Dosimetric constraints include limiting whole breast volume that receives ≥50% of prescription dose to <60%, skin dose to ≤100% of prescription dose (≤60-70% preferred), chest wall dose to ≤125% of prescription dose, Dose Homogeneity Index to >0.75 (>0.85 preferred), V 150 < 45 cc, and V 200 < 14 cc. Using an optimal implant technique coupled with optimal planning and appropriate dose constraints, a low rate of toxicity and a good-to-excellent cosmetic outcome of ≥90% is expected. IMB is an effective technique to deliver APBI for appropriately selected women with early-stage breast cancer. This consensus report has been created to assist clinicians in the appropriate practice of APBI using IMB. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Ivarsson, K; Myllymäki, L; Jansner, K; Stenram, U; Tranberg, K-G
2005-01-01
Previous studies in our laboratory have shown that interstitial laser thermotherapy (ILT) of an experimental liver tumour is superior to surgical excision, at least partly due to a laser-induced immunological effect. The aim of the present study was to investigate the time–response relationship of the ILT-induced immunisation and the cellular response of macrophages and lymphocytes. A dimethylhydrazine-induced adenocarcinoma was transplanted into the liver of syngeneic rats. Rats with tumour were treated 6–8 days later (tumour size 0.25–0.40 cm3) with ILT of tumour or resection of the tumour-bearing lobe. Two groups of rats without tumour were treated with resection of a normal liver lobe or ILT of normal liver. A challenging tumour was implanted into the liver of each rat 2, 5 or 10 weeks after primary treatment. Rats were killed 6, 12 and 48 days (or earlier due to their condition) after challenge (n=8 in all groups). Immunohistochemical techniques were used to determine lymphocytes (CD8, CD4) and macrophages (ED1, ED2) in rats having had treatment of a primary tumour. Interstitial laser thermotherapy of the first tumour was followed by eradication of challenging tumour and absence of tumour spread. This contrasted with rapid growth and spread of challenging tumour in the other groups. In the challenging vital tumour tissue and in the interface between the tumour and surroundings, the number of ED1 macrophages and CD8 lymphocytes was higher in rats having been treated with the ILT of tumour than in those having undergone resection of the tumour-bearing lobe. The number of ED2 macrophages and CD4 lymphocytes was low and did not vary between these two groups. Interstitial laser thermotherapy elicited an immune response that eradicated a challenging tumour and was associated with increased numbers of tumour-infiltrating macrophages and CD8 lymphocytes. PMID:16091763
Akay, Canan; Yaluğ, Suat
2015-01-01
Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086
Revisiting the stability of mini-implants used for orthodontic anchorage.
Yao, Chung-Chen Jane; Chang, Hao-Hueng; Chang, Jenny Zwei-Chieng; Lai, Hsiang-Hua; Lu, Shao-Chun; Chen, Yi-Jane
2015-11-01
The aim of this study is to comprehensively analyze the potential factors affecting the failure rates of three types of mini-implants used for orthodontic anchorage. Data were collected on 727 mini-implants (miniplates, predrilled titanium miniscrews, and self-drilling stainless steel miniscrews) in 220 patients. The factors related to mini-implant failure were investigated using a Chi-square test for univariate analysis and a generalized estimating equation model for multivariate analysis. The failure rate for miniplates was significantly lower than for miniscrews. All types of mini-implants, especially the self-drilling stainless steel miniscrews, showed decreased stability if the previous implantation had failed. The stability of predrilled titanium miniscrews and self-drilling stainless steel miniscrews were comparable at the first implantation. However, the failure rate of stainless steel miniscrews increased at the second implantation. The univariate analysis showed that the following variables had a significant influence on the failure rates of mini-implants: age of patient, type of mini-implant, site of implantation, and characteristics of the soft tissue around the mini-implants. The generalized estimating equation analysis revealed that mini-implants with miniscrews used in patients younger than 35 years, subjected to orthodontic loading after 30 days and implanted on the alveolar bone ridge, have a significantly higher risk of failure. This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly. Copyright © 2014. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mundinger, F.; Riechert, T.
1962-01-01
The techniques, results, and complications of stereotactic implantation of P/sup 32/, Co/sup 60/, Ta/sup 182/, Ir/sup 192/, and Au/sup 198/ in the brain of 196 patients for radiotherapy of intracranial tumors are described. A stereotactic instrument is described and illustrated which permits implantation of the radioisotopes to within 0.5 mm of the desired site. There was a clear relation between the length of survival and the kind of radioisotope applied, localization of the tumor, and amount of the tumor dosage. With glioblastomas, for instance, longest survival was noted in those with frontal localization, following Co/sup 60/ irradiation, and an averagemore » tumor dosage of 10000 to 13000 r showed best results. Similar results, with even longer survival periods, were achieved in other dedifferentiated gliomas, in which the combination of intraoperative Ta/sup 182/ or Ir/sup 192/ implantation with a postoperative interstitial Co/sup 60/ irradiation achieved the best results, in comparison with a combination of operation and x-ray therapy. The survival rate, which is nearly twice as high as in x-ray treatment, shows a significant relation to the average tumor dosage and tumor localization. The period of treatment was also shortened by 65-75% compared to the time required for fractionated x-ray therapy. In 68% of the stereotaxic hypophysis operations, according to the size of the tumor, a total activity of 25 to 55 mc of a macromolecular suspension of Au/sup 198/ was implanted which was adsorbed on small graphite particles (50 to 60 mu ). In the other cases small seeds of P/sup 32/ were placed in the tumor. The long-term results show that visual acuity had improved significantly following secondary stereotaxic irradiation, or remained unaltered without change, in comparison to those patients that had been treated by operation only. On the other hand, the percentage of unimproved and deteriorated cases is much higher in the operated group. The operative mortality with primary stereotaxic punctures was nil, whereas surgical operative mortality totaled 19%. The survival rates of 90.4% of the patients with secondary stereotaxic irradiation and 76.1% with primary stereotaxic irradiation, in compari-son with only 62% of patients with operation only, prove significantly that effectively implanted interstitial irradiation can prolong life. Among operative complications, damage to the neighboring structures was not caused by stereotaxic puncture, but was caused secondarily by radiation, above all by gamma radiation. In six of the patients, therefore, an open decompression operation was necessary. There were some general transitory reactions in the first days, especially headache and cerebrospinal fluid pressure increase among recurrent and long-term complications, in 11.5%, visual acuity grew worse and the visual field was narrowed after 0.3 to 3 yr. It was concluded that primary, and especially secondary stereotaxic irradiation of hypophysis adenomas is clearly superior to surgical operation as concerns operative mortality as well as survival rate and rate of recurrence. The rate of improvement of visual acuity was 26 to 44% higher and that of the visual field 17 to 29% higher than following surgical operation only. However, one problem not yet solved satisfactorily is the long-term radiation damage of the chiasma and optic nerve. Perhaps filling the basal cisterns with x-ray contrast medium by means of the target needle, before the placing of the isotopes, may be of help in preventing this. (BBB)« less
Effects of Molybdenum Addition on Hydrogen Desorption of TiC Precipitation-Hardened Steel
NASA Astrophysics Data System (ADS)
Song, Eun Ju; Baek, Seung-Wook; Nahm, Seung Hoon; Suh, Dong-Woo
2018-05-01
The hydrogen-trap states in TiC and MoC that have coherent interfaces with ferrite were investigated using first-principles calculation. The trapping sites of TiC were the interfaces and interstitial sites of ferrite. On the other hand, the trapping sites of MoC were ferrite interstitial sites; the interface had a negative binding energy with H. Thermal desorption analysis confirms that the amounts of diffusible hydrogen were significantly reduced by addition of Mo in Ti-bearing steel.
Feng, Sheng-Wei; Ho, Kuo-Ning; Chan, Ya-Hui; Chang, Kai-Jung; Lai, Wei-Yi; Huang, Haw-Ming
2016-12-01
The purpose of this study was to evaluate the possibility of using damping factor (DF) analysis to provide additional information on osseointegration of dental implants during the healing period. A total of 30 dental implants were installed in the bilateral femoral condyles of 15 rabbits. A DF analyzer detected with an impulse-forced vibration method and a commercialized dental implant stability analyzer based on resonance frequency (RF) analysis were used to measure the implant stability immediately after implant placement and 1, 2, 4, and 8 weeks post-surgically. Results of DF and RF analyses at different time points were compared with the corresponding osseointegration performance of dental implants via micro-computed tomography (micro-CT), histological and histomorphometrical analysis. The DF values revealed a decrease with time and reached 0.062 ± 0.007 at 8 weeks after implantation, which is almost 50% lower than the initial value. Moreover, highly significant correlations between DF values and bone volume densities (R 2 = 0.9797) and percentages of bone-to-implant contact measured at trabecular bone area (R 2 = 0.9773) were also observed. These results suggested that DF analysis combined with RF analysis results in a more sensitive assessment of changes in the dental implant/bone complex during the healing period than RF analysis alone.
Crowdsourcing Disease Biomarker Discovery Research: The IP4IC Study.
Chancellor, Michael B; Bartolone, Sarah N; Veerecke, Andrew; Lamb, Laura E
2018-05-01
Biomarker discovery is limited by readily assessable, cost efficient human samples available in large numbers that represent the entire heterogeneity of the disease. We developed a novel, active participation crowdsourcing method to determine BP-RS (Bladder Permeability Defect Risk Score). It is based on noninvasive urinary cytokines to discriminate patients with interstitial cystitis/bladder pain syndrome who had Hunner lesions from controls and patients with interstitial cystitis/bladder pain syndrome but without Hunner lesions. We performed a national crowdsourcing study in cooperation with the Interstitial Cystitis Association. Patients answered demographic, symptom severity and urinary frequency questionnaires on a HIPAA (Health Insurance Portability and Accountability Act) compliant website. Urine samples were collected at home, stabilized with a preservative and sent to Beaumont Hospital for analysis. The expression of 3 urinary cytokines was used in a machine learning algorithm to develop BP-RS. The IP4IC study collected a total of 448 urine samples, representing 153 patients (147 females and 6 males) with interstitial cystitis/bladder pain syndrome, of whom 54 (50 females and 4 males) had Hunner lesions. A total of 159 female and 136 male controls also participated, who were age matched. A defined BP-RS was calculated to predict interstitial cystitis/bladder pain syndrome with Hunner lesions or a bladder permeability defect etiology with 89% validity. In this novel participation crowdsourcing study we obtained a large number of urine samples from 46 states, which were collected at home, shipped and stored at room temperature. Using a machine learning algorithm we developed BP-RS to quantify the risk of interstitial cystitis/bladder pain syndrome with Hunner lesions, which is indicative of a bladder permeability defect etiology. To our knowledge BP-RS is the first validated urine biomarker assay for interstitial cystitis/bladder pain syndrome and one of the first biomarker assays to be developed using crowdsourcing. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.
Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J
2018-05-15
Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.
Annihilating vacancies via dynamic reflection and emission of interstitials in nano-crystal tungsten
NASA Astrophysics Data System (ADS)
Li, Xiangyan; Duan, Guohua; Xu, Yichun; Zhang, Yange; Liu, Wei; Liu, C. S.; Liang, Yunfeng; Chen, Jun-Ling; Luo, G.-N.
2017-11-01
Radiation damage not only seriously degrades the mechanical properties of tungsten (W) but also enhances hydrogen retention in the material. Introducing a large amount of defect sinks, e.g. grain boundaries (GBs) is an effective method for improving radiation-resistance of W. However, the mechanism by which the vacancies are dynamically annihilated at long timescale in nano-crystal W is still not clear. The dynamic picture for eliminating vacancies with single interstitials and small interstitial-clusters has been investigated by combining molecular dynamics, molecular statics and object Kinetic Monte Carlo methods. On one hand, the annihilation of bulk vacancies was enhanced due to the reflection of an interstitial-cluster of parallel ≤ft< 1 1 1 \\right> crowdions by the GB. The interstitial-cluster was observed to be reflected back into the grain interior when approaching a locally dense GB region. Near this region, the energy landscape for the interstitial was featured by a shoulder, different to the decreasing energy landscape of the interstitial near a locally loose region as indicative of the sink role of the GB. The bulk vacancy on the reflection path was annihilated. On the other hand, the dynamic interstitial emission efficiently anneals bulk vacancies. The single interstitial trapped at the GB firstly moved along the GB quickly and clustered to be the di-interstitial therein, reducing its mobility to a value comparable to that that for bulk vacancy diffusion. Then, the bulk vacancy was recombined via the coupled motion of the di-interstitial along the GB, the diffusion of the vacancy towards the GB and the accompanying interstitial emission. These results suggest that GBs play an efficient role in improving radiation-tolerance of nano-crystal W via reflecting highly-mobile interstitials and interstitial-clusters into the bulk and annihilating bulk vacancies, and via complex coupling of in-boundary interstitial diffusion, clustering of the interstitial and vacancy diffusion in the bulk.
NASA Astrophysics Data System (ADS)
Dardano, P.; Caliò, A.; Politi, J.; Di Palma, V.; Bevilacqua, M. F.; Rea, I.; Casalino, M.; Di Matteo, A.; Rendina, I.; De Stefano, L.
2015-06-01
Microneedles are newly developed biomedical devices, whose advantages are mainly in the non-invasiveness, discretion and versatility of use both as diagnostics and as therapeutics tool. In fact, they can be used both for drugs delivery in the interstitial fluids and for the analysis of the interstitial fluid. In this work we present the preliminary results for two devices based on micro needles in PolyEthylene (Glycol). The first for the drugs delivery includes a membrane whose optical reflected wavelength is related to the concentration of drug. Here, we present our preliminary result in diffusion of drugs between the membrane and the microneedles. The second device is gold coated and it works as electrode for the electrochemical detection of species in the interstitial fluid. A preliminary result in detection of glucose will be shown.
Characterization of the Tumor Secretome from Tumor Interstitial Fluid (TIF).
Gromov, Pavel; Gromova, Irina
2016-01-01
Tumor interstitial fluid (TIF) surrounds and perfuses bodily tumorigenic tissues and cells, and can accumulate by-products of tumors and stromal cells in a relatively local space. Interstitial fluid offers several important advantages for biomarker and therapeutic target discovery, especially for cancer. Here, we describe the most currently accepted method for recovering TIF from tumor and nonmalignant tissues that was initially performed using breast cancer tissue. TIF recovery is achieved by passive extraction of fluid from small, surgically dissected tissue specimens in phosphate-buffered saline. We also present protocols for hematoxylin and eosin (H&E) staining of snap-frozen and formalin-fixed, paraffin-embedded (FFPE) tumor sections and for proteomic profiling of TIF and matched tumor samples by high-resolution two-dimensional gel electrophoresis (2D-PAGE) to enable comparative analysis of tumor secretome and paired tumor tissue.
Radiation damage in cubic ZrO 2 and yttria-stabilized zirconia from molecular dynamics simulations
Aidhy, Dilpuneet S.; Zhang, Yanwen; Weber, William J.
2014-11-20
Here, we perform molecular dynamics simulation on cubic ZrO 2 and yttria-stabilized zirconia (YSZ) to elucidate defect cluster formation resulting from radiation damage, and evaluate the impact of Y-dopants. Interstitial clusters composed of split-interstitial building blocks, i.e., Zr-Zr or Y-Zr are formed. Moreover, oxygen vacancies control cation defect migration; in their presence, Zr interstitials aggregate to form split-interstitials whereas in their absence Zr interstitials remain immobile, as isolated single-interstitials. Y-doping prevents interstitial cluster formation due to sequestration of oxygen vacancies.
Percutaneous window chamber method for chronic intravital microscopy of sensor-tissue interactions.
Koschwanez, Heidi E; Klitzman, Bruce; Reichert, W Monty
2008-11-01
A dorsal, two-sided skin-fold window chamber model was employed previously by Gough in glucose sensor research to characterize poorly understood physiological factors affecting sensor performance. We have extended this work by developing a percutaneous one-sided window chamber model for the rodent dorsum that offers both a larger subcutaneous area and a less restrictive tissue space than previous animal models. A surgical procedure for implanting a sensor into the subcutis beneath an acrylic window (15 mm diameter) is presented. Methods to quantify changes in the microvascular network and red blood cell perfusion around the sensors using noninvasive intravital microscopy and laser Doppler flowmetry are described. The feasibility of combining interstitial glucose monitoring from an implanted sensor with intravital fluorescence microscopy was explored using a bolus injection of fluorescein and dextrose to observe real-time mass transport of a small molecule at the sensor-tissue interface. The percutaneous window chamber provides an excellent model for assessing the influence of different sensor modifications, such as surface morphologies, on neovascularization using real-time monitoring of the microvascular network and tissue perfusion. However, the tissue response to an implanted sensor was variable, and some sensors migrated entirely out of the field of view and could not be observed adequately. A percutaneous optical window provides direct, real-time images of the development and dynamics of microvascular networks, microvessel patency, and fibrotic encapsulation at the tissue-sensor interface. Additionally, observing microvessels following combined bolus injections of a fluorescent dye and glucose in the local sensor environment demonstrated a valuable technique to visualize mass transport at the sensor surface.
Majd, Sara Ehsani; Rizqy, Aditya Iman; Kaper, Hans J; Schmidt, Tannin A; Kuijer, Roel; Sharma, Prashant K
2017-07-01
Active lifestyles increase the risk of meniscal injury. A permanent meniscus implant of polycarbonate urethane (PCU) is a promising treatment to postpone/prevent total knee arthroplasty. Study of the changes in articular cartilage tribology in the presence of PCU is essential in developing the optimum meniscus implant. Therefore, a cartilage-meniscus reciprocating, sliding model was developed in vitro, mimicking the stance and swing phases of the gait cycle. The meniscus was further replaced with PCU and surface-modified PCUs (with C18 chains, mono-functional polydimethylsiloxane groups and mono-functional polytetrafluoroethylene groups) to study the changes. The coefficient of friction (COF) was calculated, and cartilage wear was determined and quantified histologically. The cartilage-meniscus sliding resulted in low COF during both stance and swing (0.01< COF <0.12) and low wear of cartilage (scores <1). The cartilage-PCU sliding, during stance, revealed similar low COFs. But during swing, the COFs were high (average ∼1, maximum 1.6), indicating a breakdown in interstitial fluid pressurization lubrication and non-effective activation of the boundary lubrication. This may lead to wear of cartilage in long term. However, under the tested conditions the wear of cartilage against PCUs was not higher than its wear against meniscus, and the cartilage was occasionally damaged. The COF decreased with increasing the contact pressure (as-per a power equation) up to 1MPa. The changes in the surface modification of PCU did not affect PCU's tribological performance. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
[Histopathological diagnostic work-up of joint endoprosthesis-associated pathologies].
Krenn, V; Perino, G; Krenn, V T; Wienert, S; Saberi, D; Hügle, T; Hopf, F; Huber, M
2016-05-01
Increasing classes of joint implants and the combination of materials results in increased and wear-associated pathologies. According to the revised consensus classification, the following types can be recognized at conventional histological examination: Type I, particle-induced type; Type II, infection type; Type III, combination type; Type IV, indifferent type; Type V arthrofibrotic type; Type VI, allergic/immunological/toxic adverse reactions and Type VII, bone pathologies. Wear particles are histopathologically characterized according to the Krenn particle algorithm which focuses on a descriptive identification of wear particles and the differentiation of other nonwear-related particles. Type VII is considered histologically when there is evidence of a perivascular/interstitial lymphocytic CD20- and CD3-positive infiltrate, presence of mast cells and eosinophils, and tissue necrosis/infarction associated with implant wear material. Since wear particle-induced toxicity cannot be differentiated with certainty from hypersensitivity/allergic reaction on histological examination, immunological-allergological and clinical data should be used as supplementary criteria for the differential diagnosis. Tissue sampling should be performed from periprosthetic soft tissue with location mapping and when feasible also from bone tissue. Additional information regarding the type of implant and clinical, radiological, immunological, and microbiology data should be available to the pathologist. Further immunohistochemical studies are recommended in the following settings: infection (CD15, CD20, CD68); prosthesis-associated arthrofibrosis (β‑catenin); allergic/immunologic/toxic adverse reactions (CD20, CD3, CD4, CD8, CD117 and for T‑cell characterization T‑bet, GATA-3, and FOXP3).
Interstitial cystitis - resources
Resources - interstitial cystitis ... The following organizations are good resources for information on interstitial cystitis : Interstitial Cystitis Association -- www.ichelp.org National Institute of Diabetes and Digestive and Kidney Diseases -- www. ...
Buda, N; Piskunowicz, M; Porzezińska, M; Kosiak, W; Zdrojewski, Z
2016-08-01
Patients with a diagnosed systemic connective tissue disease require regular monitoring from the point of view of interstitial lung disease. The main aim of this work is a description of the criteria for pulmonary fibrosis and the degree of the severity of the fibrosis during the course of interstitial lung disease through the TLU (transthoracic lung ultrasound). 52 patients with diagnosed diffuse interstitial lung disease were qualified for this research, together with 50 volunteers in the control group. The patients in both groups were over 18 years of age and were of both sexes. The results of the TLU of the patients underwent statistical analysis and were compared to High-Resolution Computed Tomography (HRCT) results. As a consequence of the statistical analysis, we defined our own criteria for pulmonary fibrosis in TLU: irregularity of the pleura line, tightening of the pleura line, the fragmentary nature of the pleura line, blurring of the pleura line, thickening of the pleura line, artifacts of line B ≤ 3 and ≥ 4, artifacts of Am line and subpleural consolidations < 5 mm. As a result of the conducted research, a scale of severity of pulmonary fibrosis in TLU was devised (UFI - Ultrasound Fibrosis Index), enabling a division to be made into mild, moderate and severe cases. Transthoracic Lung Ultrasonography (TLU) gives a new outlook on the diagnostic possibilities, non-invasive and devoid of ionising radiation, of pulmonary fibrosis. This research work has allowed to discover two new ultrasound symptoms of pulmonary fibrosis (blurred pleural line and Am lines). © Georg Thieme Verlag KG Stuttgart · New York.
Loch-Wilkinson, Anna; Beath, Kenneth J; Knight, Robert John William; Wessels, William Louis Fick; Magnusson, Mark; Papadopoulos, Tim; Connell, Tony; Lofts, Julian; Locke, Michelle; Hopper, Ingrid; Cooter, Rodney; Vickery, Karen; Joshi, Preeti Avinash; Prince, H Miles; Deva, Anand K
2017-10-01
The association between breast implants and breast implant-associated anaplastic large cell lymphoma (ALCL) has been confirmed. Implant-related risk has been difficult to estimate to date due to incomplete datasets. All cases in Australia and New Zealand were identified and analyzed. Textured implants reported in this group were subjected to surface area analysis. Sales data from three leading breast implant manufacturers (i.e., Mentor, Allergan, and Silimed) dating back to 1999 were secured to estimate implant-specific risk. Fifty-five cases of breast implant-associated ALCL were diagnosed in Australia and New Zealand between 2007 and 2016. The mean age of patients was 47.1 years and the mean time of implant exposure was 7.46 years. There were four deaths in the series related to mass and/or metastatic presentation. All patients were exposed to textured implants. Surface area analysis confirmed that higher surface area was associated with 64 of the 75 implants used (85.3 percent). Biocell salt loss textured (Allergan, Inamed, and McGhan) implants accounted for 58.7 percent of the implants used in this series. Comparative analysis showed the risk of developing breast implant-associated ALCL to be 14.11 times higher with Biocell textured implants and 10.84 higher with polyurethane (Silimed) textured implants compared with Siltex textured implants. This study has calculated implant-specific risk of breast implant-associated ALCL. Higher-surface-area textured implants have been shown to significantly increase the risk of breast implant-associated ALCL in Australia and New Zealand. The authors present a unifying hypothesis to explain these observations.
NASA Astrophysics Data System (ADS)
Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.
2017-08-01
The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.
Strietzel, Frank Peter; Neumann, Konrad; Hertel, Moritz
2015-01-01
Objective To address the focused question, is there an impact of platform switching (PS) on marginal bone level (MBL) changes around endosseous implants compared to implants with platform matching (PM) implant-abutment configurations? Material and methods A systematic literature search was conducted using electronic databases PubMed, Web of Science, Journals@Ovid Full Text and Embase, manual search for human randomized clinical trials (RCTs) and prospective clinical controlled cohort studies (PCCS) reporting on MBL changes at implants with PS-, compared with PM-implant-abutment connections, published between 2005 and June 2013. Results Twenty-two publications were eligible for the systematic review. The qualitative analysis of 15 RCTs and seven PCCS revealed more studies (13 RCTs and three PCCS) showing a significantly less mean marginal bone loss around implants with PS- compared to PM-implant-abutment connections, indicating a clear tendency favoring the PS technique. A meta-analysis including 13 RCTs revealed a significantly less mean MBL change (0.49 mm [CI95% 0.38; 0.60]) at PS implants, compared with PM implants (1.01 mm [CI95% 0.62; 1.40] (P < 0.0001). Conclusions The meta-analysis revealed a significantly less mean MBL change at implants with a PS compared to PM-implant-abutment configuration. Studies included herein showed an unclear as well as high risk of bias mostly, and relatively short follow-up periods. The qualitative analysis revealed a tendency favoring the PS technique to prevent or minimize peri-implant marginal bone loss compared with PM technique. Due to heterogeneity of the included studies, their results require cautious interpretation. PMID:24438506
Cinzia, Raso; Carlo, Cosentino; Marco, Gaspari; Natalia, Malara; Xuemei, Han; Daniel, McClatchy; Kyu, Park Sung; Maria, Renne; Nuria, Vadalà; Ubaldo, Prati; Giovanni, Cuda; Vincenzo, Mollace; Francesco, Amato; Yates, John R.
2012-01-01
Cancer is currently considered as the end point of numerous genomic and epigenomic mutations and as the result of the interaction of transformed cells within the stromal microenvironment. The present work focuses on breast cancer, one of the most common malignancies affecting the female population in industrialized countries. In this study we perform a proteomic analysis of bioptic samples from human breast cancer, namely interstitial fluids and primary cells, normal vs disease tissues, using Tandem mass Tags (TmT) quantitative mass spectrometry combined with the MudPIT technique. To the best of our knowledge this work, with over 1700 proteins identified, represents the most comprehensive characterization of the breast cancer interstitial fluid proteome to date. Network analysis was used to identify functionally active networks in the breast cancer associated samples. From the list of differentially expressed genes we have retrieved the associated functional interaction networks. Many different signaling pathways were found activated, strongly linked to invasion, metastasis development, proliferation and with a significant cross-talking rate. This pilot study presents evidence that the proposed quantitative proteomic approach can be applied to discriminate between normal and tumoral samples and for the discovery of yet unknown carcinogenesis mechanisms and therapeutic strategies. PMID:22563702
Radek, Manuel; Liedke, Bartosz; Schmidt, Bernd; Voelskow, Matthias; Bischoff, Lothar; Lundsgaard Hansen, John; Nylandsted Larsen, Arne; Bougeard, Dominique; Böttger, Roman; Prucnal, Slawomir; Posselt, Matthias; Bracht, Hartmut
2017-01-01
Crystalline and preamorphized isotope multilayers are utilized to investigate the dependence of ion beam mixing in silicon (Si), germanium (Ge), and silicon germanium (SiGe) on the atomic structure of the sample, temperature, ion flux, and electrical doping by the implanted ions. The magnitude of mixing is determined by secondary ion mass spectrometry. Rutherford backscattering spectrometry in channeling geometry, Raman spectroscopy, and transmission electron microscopy provide information about the structural state after ion irradiation. Different temperature regimes with characteristic mixing properties are identified. A disparity in atomic mixing of Si and Ge becomes evident while SiGe shows an intermediate behavior. Overall, atomic mixing increases with temperature, and it is stronger in the amorphous than in the crystalline state. Ion-beam-induced mixing in Ge shows no dependence on doping by the implanted ions. In contrast, a doping effect is found in Si at higher temperature. Molecular dynamics simulations clearly show that ion beam mixing in Ge is mainly determined by the thermal spike mechanism. In the case of Si thermal spike, mixing prevails at low temperature whereas ion beam-induced enhanced self-diffusion dominates the atomic mixing at high temperature. The latter process is attributed to highly mobile Si di-interstitials formed under irradiation and during damage annealing. PMID:28773172
Radek, Manuel; Liedke, Bartosz; Schmidt, Bernd; Voelskow, Matthias; Bischoff, Lothar; Hansen, John Lundsgaard; Larsen, Arne Nylandsted; Bougeard, Dominique; Böttger, Roman; Prucnal, Slawomir; Posselt, Matthias; Bracht, Hartmut
2017-07-17
Crystalline and preamorphized isotope multilayers are utilized to investigate the dependence of ion beam mixing in silicon (Si), germanium (Ge), and silicon germanium (SiGe) on the atomic structure of the sample, temperature, ion flux, and electrical doping by the implanted ions. The magnitude of mixing is determined by secondary ion mass spectrometry. Rutherford backscattering spectrometry in channeling geometry, Raman spectroscopy, and transmission electron microscopy provide information about the structural state after ion irradiation. Different temperature regimes with characteristic mixing properties are identified. A disparity in atomic mixing of Si and Ge becomes evident while SiGe shows an intermediate behavior. Overall, atomic mixing increases with temperature, and it is stronger in the amorphous than in the crystalline state. Ion-beam-induced mixing in Ge shows no dependence on doping by the implanted ions. In contrast, a doping effect is found in Si at higher temperature. Molecular dynamics simulations clearly show that ion beam mixing in Ge is mainly determined by the thermal spike mechanism. In the case of Si thermal spike, mixing prevails at low temperature whereas ion beam-induced enhanced self-diffusion dominates the atomic mixing at high temperature. The latter process is attributed to highly mobile Si di-interstitials formed under irradiation and during damage annealing.
Dynamics of Defects and Dopants in Complex Systems: Si and Oxide Surfaces and Interfaces
NASA Astrophysics Data System (ADS)
Kirichenko, Taras; Yu, Decai; Banarjee, Sanjay; Hwang, Gyeong
2004-10-01
Fabrication of forthcoming nanometer scale electronic devices faces many difficulties including formation of extremely shallow and highly doped junctions. At present, ultra-low-energy ion implantation followed by high-temperature thermal annealing is most widely used to fabricate such ultra-shallow junctions. In the process, a great challenge lies in achieving precise control of redistribution and electrical activation of dopant impurities. Native defects (such as vacancies and interstitials) generated during implantation are known to be mainly responsible for the TED and also influence significantly the electrical activation/deactivation. Defect-dopant dynamics is rather well understood in crystalline Si and SiO2. However, little is known about their diffusion and annihilation (or precipitation) at the surfaces and interfaces, despite its growing importance in determining junction profiles as device dimensions get smaller. In this talk, we will present our density functional theory calculation results on the atomic and electronic structure and dynamical behavior of native defects and dopant-defect complexes in disordered/strained Si and oxide systems, such as i) clean and absorbent-modified Si(100) surface and subsurface layers, ii) amorphous-crystalline Si interfaces and iii) amorphous SiO2/Si interfaces. The fundamental understanding and data is essential in developing a comprehensive kinetic model for junction formation, which would contribute greatly in improving current process technologies.
Towards the use of bioresorbable fibers in time-domain diffuse optics.
Di Sieno, Laura; Boetti, Nadia G; Dalla Mora, Alberto; Pugliese, Diego; Farina, Andrea; Konugolu Venkata Sekar, Sanathana; Ceci-Ginistrelli, Edoardo; Janner, Davide; Pifferi, Antonio; Milanese, Daniel
2018-01-01
In the last years bioresorbable materials are gaining increasing interest for building implantable optical components for medical devices. In this work we show the fabrication of bioresorbable optical fibers designed for diffuse optics applications, featuring large core diameter (up to 200 μm) and numerical aperture (0.17) to maximize the collection efficiency of diffused light. We demonstrate the suitability of bioresorbable fibers for time-domain diffuse optical spectroscopy firstly checking the intrinsic performances of the setup by acquiring the instrument response function. We then validate on phantoms the use of bioresorbable fibers by applying the MEDPHOT protocol to assess the performance of the system in measuring optical properties (namely, absorption and scattering coefficients) of homogeneous media. Further, we show an ex-vivo validation on a chicken breast by measuring the absorption and scattering spectra in the 500-1100 nm range using interstitially inserted bioresorbable fibers. This work represents a step toward a new way to look inside the body using optical fibers that can be implanted in patients. These fibers could be useful either for diagnostic (e. g. for monitoring the evolution after surgical interventions) or treatment (e. g. photodynamic therapy) purposes. Picture: Microscopy image of the 100 μm core bioresorbable fiber. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cell Based Metabolic Barriers to Glucose Diffusion: Macrophages and Continuous Glucose Monitoring
Klueh, Ulrike; Frailey, Jackman; Qiao, Yi; Antar, Omar; Kreutzer, Donald L.
2014-01-01
It is assumed that MQ are central to glucose sensor bio-fouling and therefore have a major negative impact on continuous glucose monitoring (CGM) performance in vivo. However to our knowledge there is no data in the literature to directly support or refute this assumption. Since glucose and oxygen (O2) are key to glucose sensor function in vivo, understanding and controlling glucose and O2 metabolic activity of MQ is likely key to successful glucose sensor performance. We hypothesized that the accumulation of MQ at the glucose sensor-tissue interface will act as “Cell Based Metabolic Barriers” (CBMB) to glucose diffusing from the interstitial tissue compartment to the implanted glucose sensor and as such creating an artificially low sensor output, thereby compromising sensor function and CGM. Our studies demonstrated that 1) direct injections of MQ at in vivo sensor implantation sites dramatically decreased sensor output (measured in nA), 2) addition of MQ to glucose sensors in vitro resulted in a rapid and dramatic fall in sensor output and 3) lymphocytes did not affect sensor function in vitro or in vivo. These data support our hypothesis that MQ can act as metabolic barriers to glucose and O2 diffusion in vivo and in vitro. PMID:24461328
Cell based metabolic barriers to glucose diffusion: macrophages and continuous glucose monitoring.
Klueh, Ulrike; Frailey, Jackman T; Qiao, Yi; Antar, Omar; Kreutzer, Donald L
2014-03-01
It is assumed that MQ are central to glucose sensor bio-fouling and therefore have a major negative impact on continuous glucose monitoring (CGM) performance in vivo. However to our knowledge there is no data in the literature to directly support or refute this assumption. Since glucose and oxygen (O2) are key to glucose sensor function in vivo, understanding and controlling glucose and O2 metabolic activity of MQ is likely key to successful glucose sensor performance. We hypothesized that the accumulation of MQ at the glucose sensor-tissue interface will act as "Cell Based Metabolic Barriers" (CBMB) to glucose diffusing from the interstitial tissue compartment to the implanted glucose sensor and as such creating an artificially low sensor output, thereby compromising sensor function and CGM. Our studies demonstrated that 1) direct injections of MQ at in vivo sensor implantation sites dramatically decreased sensor output (measured in nA), 2) addition of MQ to glucose sensors in vitro resulted in a rapid and dramatic fall in sensor output and 3) lymphocytes did not affect sensor function in vitro or in vivo. These data support our hypothesis that MQ can act as metabolic barriers to glucose and O2 diffusion in vivo and in vitro. Copyright © 2014 Elsevier Ltd. All rights reserved.
Wear and Damage of Articular Cartilage with Friction Against Orthopaedic Implant Materials
Oungoulian, Sevan R.; Durney, Krista M.; Jones, Brian K.; Ahmad, Christopher S.; Hung, Clark T.; Ateshian, Gerard A.
2015-01-01
The objective of this study was to measure the wear response of immature bovine articular cartilage tested against glass or alloys used in hemiarthroplasties. Two cobalt chromium alloys and a stainless steel alloy were selected for these investigations. The surface roughness of one of the cobalt chromium alloys was also varied within the range considered acceptable by regulatory agencies. Cartilage disks were tested in a configuration that promoted loss of interstitial fluid pressurization to accelerate conditions believed to occur in hemiarthroplasties. Results showed that considerably more damage occurred in cartilage samples tested against stainless steel (10 nm roughness) and low carbon cobalt chromium alloy (27 nm roughness) compared to glass (10 nm) and smoother low or high carbon cobalt chromium (10 nm). The two materials producing the greatest damage also exhibited higher equilibrium friction coefficients. Cartilage damage occurred primarily in the form of delamination at the interface between the superficial tangential zone and the transitional middle zone, with much less evidence of abrasive wear at the articular surface. These results suggest that cartilage damage from frictional loading occurs as a result of subsurface fatigue failure leading to the delamination. Surface chemistry and surface roughness of implant materials can have a significant influence on tissue damage, even when using materials and roughness values that satisfy regulatory requirements. PMID:25912663
Subgingival microbiome in patients with healthy and ailing dental implants
Zheng, Hui; Xu, Lixin; Wang, Zicheng; Li, Lianshuo; Zhang, Jieni; Zhang, Qian; Chen, Ting; Lin, Jiuxiang; Chen, Feng
2015-01-01
Dental implants are commonly used to replace missing teeth. However, the dysbiotic polymicrobial communities of peri-implant sites are responsible for peri-implant diseases, such as peri-implant mucositis and peri-implantitis. In this study, we analyzed the microbial characteristics of oral plaque from peri-implant pockets or sulci of healthy implants (n = 10), peri-implant mucositis (n = 8) and peri-implantitis (n = 6) sites using pyrosequencing of the 16S rRNA gene. An increase in microbial diversity was observed in subgingival sites of ailing implants, compared with healthy implants. Microbial co-occurrence analysis revealed that periodontal pathogens, such as Porphyromonas gingivalis, Tannerella forsythia, and Prevotella intermedia, were clustered into modules in the peri-implant mucositis network. Putative pathogens associated with peri-implantitis were present at a moderate relative abundance in peri-implant mucositis, suggesting that peri-implant mucositis an important early transitional phase during the development of peri-implantitis. Furthermore, the relative abundance of Eubacterium was increased at peri-implantitis locations, and co-occurrence analysis revealed that Eubacterium minutum was correlated with Prevotella intermedia in peri-implantitis sites, which suggests the association of Eubacterium with peri-implantitis. This study indicates that periodontal pathogens may play important roles in the shifting of healthy implant status to peri-implant disease. PMID:26077225
Primary invasive squamous carcinoma of the vagina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pride, G.L.; Schultz, A.E.; Chuprevich, T.W.
1979-02-01
Forty-three cases of primary vaginal squamous cell cancer were treated at the University of Wisconsin Hospital between 1956 and 1971. These cases comprised of 1.2% of patients admitted to the University Hospital with female genital tract cancer. Evidence is presented to support a modification of the currently accepted FIGO staging system for vaginal carcinoma (Stage II disease). Radiation therapy using both external beam and brachyradium equivalents or interstitial implantation of suitable isotopes was an effective method for the treatment of patients having early and locally advanced invasive vaginal cancer. The 5-year absolute survival rate for the entire series was 37.2%.more » Absolute survival rate by modified FIGO clinical staging was 66% for Stages I and IIA, 31% for Stage IIB, 25% for Stage III, and 0% for Stage IV.« less
Gredes, Tomasz; Kubasiewicz-Ross, Pawel; Gedrange, Tomasz; Dominiak, Marzena; Kunert-Keil, Christiane
2014-08-01
New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.
Influence of trabecular bone quality and implantation direction on press-fit mechanics.
Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E
2017-02-01
Achieving primary stability of uncemented press-fit prostheses in patients with poor quality bone can involve axial implantation forces large enough to cause bone fracture. Radial implantation eliminates intraoperative impaction forces and could prevent this damage. Platens of two commercial implant surfaces ("Beaded" and "Flaked") were implanted onto trabecular bone specimens of varying quality in a press-fit simulator. Samples were implanted with varying interference, either axially (shear) or radially (normal). Push-in and pull-out forces were measured to assess stability. Microstructural changes in the bone were determined from μCT analysis. For force-defined implantation analysis, push-in and pull-out forces both increased proportionally with increasing radial force, independent of implantation direction, bone quality or implant surface. For position-defined implantation analysis, pull-out forces were generally found to increase with interference and to be greater for radial than axial implantation direction, and to be lower for poor quality bone. Bone density increased locally at the tested interface due to implantation, in particular for the Beaded surface under axial implantation. If a safe radial stress can be determined for cortical bone in a particular patient, the associated implantation force, and pull-out force which represents primary stability, can be directly derived, regardless of implantation direction, bone quality or implant surface. Radial implantation delivers primary stability that is no worse than that for axial implantation and may eliminate potentially damaging impaction forces. Development of implant designs based on this principal might improve implant fixation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:224-233, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapur, P; Ford, J; Moghanaki, D
Purpose: To evaluate the Medical Event (ME) criteria for I-125 prostate implants based on the assessment of post implant dosimetry on “Day0”/“Day30” imaging. The new ME criteria do not mandate a timeframe for this assessment. The compliance criteria are: more than 80% of the activity from the written directive for treatment site (TS) must be implanted inside TS, and doses to 1cc of either uninvolved rectum (D1-UR) or uninvolved bladder (D1-UB), or 2cc of other non-specified tissue (D2-UT) must be less than 150% of the planned dose. Methods: “Day0”/“Day30” post-implant analyses for 25 patients were evaluated. Treatment plans had amore » peripheral loading pattern with 2 core needles placed at least 10 mm away from urethra, with several seeds planned outside of the prostate for adequate target coverage. TS were a uniform 5 mm expansion of the prostate, except posteriorly (no expansion). Results: “Day0”/“Day30”analyses found no MEs. The relative changes for D1-UR, D1-UB, and D2-UT were (ranges): [−37.0, 38.2]%, [−96.5, 74.7]%, and [−41.2, 37.7]%. Furthermore, changes did not correlate with prostate volume changes of −18.7% [σ:16.0%, range:−60.5%, +6.4%]. These unfavorable changes did not lead to ME at “Day30” because these values were generally well below 150% at “Day0”. However, D2-UT dose values exceeded those for D1-UR and D1-UB at both “Day0”/“Day30”. Conclusion: The total activity was relatively insensitive to changes in target volume from “Day0” to ”Day30”. The dose metrics of interest, albeit susceptible to large, often unfavorable changes, remained less than the 150% threshold. Data from this study suggest that “Day0” can be used for the regulatory compliance evaluation. However, further evaluation at “Day30” is advisable if D2-UT is 110% or above (based on the largest D2-UT increase of 37.7% observed in this patient population). Future rigorous statistical analysis of a larger cohort will afford a refinement of this recommendation.« less
Yamamoto, Yuzo; Okamoto, Isamu; Otsubo, Kohei; Iwama, Eiji; Hamada, Naoki; Harada, Taishi; Takayama, Koichi; Nakanishi, Yoichi
2015-10-01
Alectinib, the second generation anaplastic lymphoma kinase (ALK) inhibitor, has significant potency in patients with ALK rearrangement positive non-small cell lung cancer (NSCLC), and its toxicity is generally well tolerable. We report a patient who developed severe acute interstitial lung disease after alectinib treatment. An 86-year-old woman with stage IV lung adenocarcinoma positive for rearrangement of ALK gene was treated with alectinib. On the 215th day after initiation of alectinib administration, she was admitted to our hospital with the symptom of progressive dyspnea. Computed tomography (CT) revealed diffuse ground glass opacities and consolidations in both lungs, and analysis of bronchoalveolar lavage fluid revealed pronounced lymphocytosis. There was no evidence of infection or other specific causes of her condition, and she was therefore diagnosed with interstitial lung disease induced by alectinib. Her CT findings and respiratory condition improved after steroid pulse therapy. As far as we are aware, this is the first reported case of alectinib-induced severe interstitial lung disease (ILD). We should be aware of the possibility of such a severe adverse event and should therefore carefully monitor patients treated with this drug.
Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification.
Hamed, Hamed A; Marzook, Hamdy A; Ghoneem, Nahed E; El-Anwar, Mohamed I
2018-02-15
This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bukowiecki, L.J.; Geloeen, A.; Collet, A.J.
1986-06-01
The mechanisms of brown adipocyte proliferation and differentiation during cold acclimation (and/or adaptation to hyperphagia) have been studied by quantitative photonic radioautography. (/sup 3/H)thymidine was injected to warm-acclimated (25/sup 0/C) rats and to animals exposed to 5/sup 0/C for 2 days. Samples of interscapular brown adipose tissue were collected for quantitative analysis of mitotic frequencies at various periods of time (4 h-15 days) after the injection of (/sup 3/H)thymidine, the rats being maintained at the temperatures to which they were initially exposed. It was found that cold exposure for 2 days markedly enhanced mitotic activity in endothelial cells, interstitial cells,more » and brown preadipocytes rather than in fully differentiated brown adipocytes. The total tissue labeling index (percent of labeled nuclei) increased approx.70 times over control values. The authors now report that cellular labeling progressively increased in mature brown adipocytes during cold acclimation, whereas it correspondingly decreased in interstitial cells and brown preadipocytes. This indicates that the sequence of events for cellular differentiation is interstitial cells ..-->.. brown preadipocytes ..-->.. mature brown adipocytes. Remarkable, labeling frequency did not change in endothelial cells during cold acclimation demonstrating that these cells cannot be considered as progenitors of brown adipocytes. It is suggested that brown adipocyte proliferation and differentiation from interstitial cells represent the fundamental phenomena explaining the enhanced capacity of cold-acclimated and/or hyperphagic rats to respond calorigenically to catecholamines.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tabatowski, K.; Roggli, V.L.; Fulkerson, W.J.
A case of biopsy-proven giant cell interstitial pneumonia in a patient with occupational exposure to hard-metal dust is reported. Bronchial washings performed several days prior to open-lung biopsy yielded an almost exclusive population of nonpigmented alveolar macrophages and pleomorphic, phagocytic multinucleated giant cells. Microorganisms, viral inclusions in the giant cells, epithelioid histiocytes and well-formed granulomas were not seen. This cytologic picture strongly suggests the presence of giant cell interstitial pneumonia in a patient with restrictive lung disease, particularly when exposure to hard-metal dust is known or suspected. A specific diagnosis early in the course of the disease may facilitate removalmore » of the individual from the workplace and forestall the development of end-stage interstitial fibrosis. Additionally, the working environment may be modified to minimize inhalational exposure. Recognition of this entity by the cytopathologist may direct diagnostic efforts toward accurate histologic evaluation and the identification of particulates by microprobe analysis of either cellular or biopsy material.« less
Yuan, Haiming; Meng, Zhe; Zhang, Lina; Luo, Xiangyang; Liu, Liping; Chen, Mengfan; Li, Xinwei; Zhao, Weiwei; Liang, Liyang
2016-01-01
Interstitial duplications distal to 15q13 are very rare. Here, we reported a 14-year-old boy with severe short stature, delayed bone age, hypogonadism, global developmental delay and intellectual disability. His had distinctive facial features including macrocephaly, broad forehead, deep-set and widely spaced eyes, broad nose bridge, shallow philtrum and thick lips. A de novo 6.4 Mb interstitial duplication of 15q15.3q21.2 was detected by chromosomal microarray analysis. We compared our patient's clinical phenotypes with those of several individuals with overlapping duplications and several candidate genes responsible for the phenotypes were identified as well. The results suggest a novel contiguous gene duplication syndrome characterized with shared features including short stature, hypogonadism, global developmental delay and other congenital anomalies.
NASA Astrophysics Data System (ADS)
Yang, Chengkai; Shao, Ruiwen; Mi, Yingying; Shen, Lanyao; Zhao, Binglu; wang, Qian; Wu, Kai; Lui, Wen; Gao, Peng; Zhou, Henghui
2018-02-01
High nickel cathodes can deliver higher capacity with lower cost than conventional LiCoO2, however, the irreversible structural and morphology degradation with long-term cycling hinder their further application. In this paper, LiNi0.815Co0.15Al0.035O2 agglomerates are treated by LiNi0.333Co0.333Mn0.333O2 coating to get a stable interstitial layer without capacity loss. The interstitial layer is about 10 nm in thickness and has a layered (R-3m) structure, which can improve the chemical and mechanical stability of cathode materials with capacity retention of 88.5% after 200 cycles. The structural analysis and in-situ compression test proves that the morphology degradation is a fatigue process within long-term electrochemical reaction, and the coated sample has an excellent elastic recovery capacity thus leading to long cycle life.
Micro finite element analysis of dental implants under different loading conditions.
Marcián, Petr; Wolff, Jan; Horáčková, Ladislava; Kaiser, Jozef; Zikmund, Tomáš; Borák, Libor
2018-05-01
Osseointegration is paramount for the longevity of dental implants and is significantly influenced by biomechanical stimuli. The aim of the present study was to assess the micro-strain and displacement induced by loaded dental implants at different stages of osseointegration using finite element analysis (FEA). Computational models of two mandible segments with different trabecular densities were constructed using microCT data. Three different implant loading directions and two osseointegration stages were considered in the stress-strain analysis of the bone-implant assembly. The bony segments were analyzed using two approaches. The first approach was based on Mechanostat strain intervals and the second approach was based on tensile/compression yield strains. The results of this study revealed that bone surrounding dental implants is critically strained in cases when only a partial osseointegration is present and when an implant is loaded by buccolingual forces. In such cases, implants also encounter high stresses. Displacements of partially-osseointegrated implant are significantly larger than those of fully-osseointegrated implants. It can be concluded that the partial osseointegration is a potential risk in terms of implant longevity. Copyright © 2018 Elsevier Ltd. All rights reserved.
Reinhardt, C D; Wagner, J J
2014-10-01
A meta-analysis of studies evaluating feedlot steer implant programs was conducted to evaluate the differential effects of anabolic implant dosage on feedlot performance and carcass traits. The effect sizes of the implant dosage of interest vs. negative controls and vs. other implant dosages on various dependent variables (ADG, F:G, DMI, dressing percentage [DP], HCW, yield grade, percentage Choice or higher, and marbling score) were calculated. Treatments used for comparisons included no implant, EST (20 mg estradiol benzoate + 200 mg progesterone, 36 mg zeranol, or 72 mg zeranol), ET120 (24 mg estradiol 17β + 120 mg trenbolone acetate [TBA]), and ET200 (28 mg estradiol benzoate + 200 mg TBA or 20 mg estradiol-17β + 200 mg TBA). In the first analysis, the 3 implant dosages were compared to negative control. A second analysis was conducted to compare ET120 vs. ET200 using only studies that included a direct comparison of these 2 dosages. The number of studies included in the analysis for each implant dosage and response variable ranged from 34 to 7. A mixed model was used to evaluate individual implant treatments; implant dosage was a fixed effect, and individual study was included as a random effect. All dosages had greater ADG, DMI, and HCW and lower F:G, percentage Choice, and marbling score vs. negative controls (P < 0.05) In the second direct comparison analysis, ET200 tended to have greater ADG (P = 0.10) and HCW (P = 0.07) and had lower F:G (P < 0.01) and percentage of carcasses grading Choice or greater (P < 0.01) vs. ET120. Differences in HCW between ET120 and ET200 diminished numerically with increasing days of implant activity (P < 0.01). All dosages of implants evaluated herein increased performance and decreased quality grade vs. negative controls. Combination implants containing estrogen (E) and 200 mg TBA have greater potency for growth promotion than implants containing E+120 mg TBA resulting in slightly greater performance.
Tallarico, Marco; Canullo, Luigi; Caneva, Martina; Özcan, Mutlu
2017-07-01
The aim of this systematic review and meta-analysis was to evaluate the microbial colonization at the implant-abutment interfaces (IAI) on bone-level implants and to identify possible association with peri-implant conditions. The focus question aimed to answer whether two-piece osseointegrated implants, in function for at least 1 year, in human, relate to higher bacterial count and the onset of periimplantitis, compared to healthy peri-implant conditions. Search strategy encompassed the on-line (MedLine, Google scholar, Cochrane library) literature from 1990 up to March 2015 published in English using combinations of MeSH (Medical Subject Headings) and search terms. Quality assessment of selected full-text articles was performed according to the ARRIVE and CONSORT statement guidelines. For data analysis, the total bacterial count of Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, Prevotella intermedia, and Fusobacterium nucleatum was calculated and compared to IAI with or without peri-implant pathology. A total of 14 articles, reporting data from 1126 implants, fulfilled the inclusion criteria and subjected to quality assessment. The selected studies revealed contamination of the IAI, in patients who received two-piece implant systems. Meta-analysis indicated significant difference in total bacterial count between implants affected by periimplantitis versus healthy peri-implant tissues (0.387±0.055; 95% CI 0.279-0.496). Less bacterial counts were identified in the healthy IAI for all the investigated gram-negative bacteria except for T. forsythia. Significantly higher bacterial counts were found for periodontal pathogenic bacteria within the IAI of implants in patients with periimplantitis compared to those implants surrounded by healthy peri-implant tissues. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Fabrication and characterization of a pd nanowire-based glucose biofuel cell
NASA Astrophysics Data System (ADS)
Amoah, Kweku Obeng
The use of glucose as a source in biofuel cell technology has received a lot of attention in part due to the potential applications of such systems. In addition to the being a clean energy alternative, it provides a pathway for implantable microelectronic devices, such as pacemakers, to be powered by interstitial fluid and eliminate the need for batteries. Furthermore, using interstitial fluid as fuel sources will drastically reduce necessary invasive surgeries to replace batteries. Additionally, cost to such patients will be reduced while quality of life enhanced. The research presents a unique platform for harvesting energy from glucose. Using semiconductor cleanroom techniques, electrically conductive palladium nanowires are grown on anodized aluminum oxide templates using silicon and glass as supporting substrates. Photolithography is used to create two non-continuous gold windows and contact pads on the substrates. AAO templates are attached to the two gold windows and palladium nanowires are electrochemically grown on the AAO templates. Glucose oxidase and catalase are immobilized on the anode and laccase on the cathode. In the presence of glucose, electrons are released that result in the generation of voltage and current. The current-voltage behavior of the fuel cell, as well as electrochemical properties, is characterized using standard performance metrics. In 5 mM glucose solution with a neutral pH of 7.3, the open circuit voltage obtained was 335 mV and the short circuit current of 6 microA to yield a maximum power output of 1.38 microW.
Skarlatos, S; Brand, P H; Metting, P J; Britton, S L
1994-01-01
1. Previous work has demonstrated a positive relationship between experimentally induced changes in arterial pressure (AP) and renal interstitial hydrostatic pressure (RIHP). The purpose of the present study was to test the hypothesis that RIHP is positively correlated with the normal changes in AP that occur spontaneously in conscious rats. 2. Rats were chronically instrumented for the recording of AP (via an aortic catheter) and RIHP. RIHP was measured by implanting a Millar microtransducer, whose tip had been encapsulated in a 35 microns pore polyethylene matrix (5 mm long, 2 mm o.d.), approximately 5 mm below the renal cortical surface. 3. A total of 56 h of simultaneous analog recording of AP and RIHP was obtained from ten rats. Each 1 h segment was digitized and evaluated at frequencies of 1, 0.1, 0.02 and 0.01 Hz. 4. In forty-nine out of fifty-six of these 1 h recordings taken at 1 Hz, there were significant positive linear correlations between AP and RIHP (mean r = 0.32) with a mean slope of 0.11 mmHg RIHP/1 mmHg AP. Low-pass filtering to 0.01 Hz significantly increased the r value to 0.48. 5. These results demonstrate that spontaneous changes in AP and RIHP are positively correlated. The spontaneous coupling of AP and RIHP may be of importance in the regulation of salt and water excretion by the pressure diuresis mechanism. PMID:7707240
Quantitative analysis of titanium-induced artifacts and correlated factors during micro-CT scanning.
Li, Jun Yuan; Pow, Edmond Ho Nang; Zheng, Li Wu; Ma, Li; Kwong, Dora Lai Wan; Cheung, Lim Kwong
2014-04-01
To investigate the impact of cover screw, resin embedment, and implant angulation on artifact of microcomputed tomography (micro-CT) scanning for implant. A total of twelve implants were randomly divided into 4 groups: (i) implant only; (ii) implant with cover screw; (iii) implant with resin embedment; and (iv) implants with cover screw and resin embedment. Implants angulation at 0°, 45°, and 90° were scanned by micro-CT. Images were assessed, and the ratio of artifact volume to total volume (AV/TV) was calculated. A multiple regression analysis in stepwise model was used to determine the significance of different factors. One-way ANOVA was performed to identify which combination of factors could minimize the artifact. In the regression analysis, implant angulation was identified as the best predictor for artifact among the factors (P < 0.001). Resin embedment also had significant effect on artifact volume (P = 0.028), while cover screw had not (P > 0.05). Non-embedded implants with the axis parallel to X-ray source of micro-CT produced minimal artifact. Implant angulation and resin embedment affected the artifact volume of micro-CT scanning for implant, while cover screw did not. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo
2016-02-01
To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.
In vivo osseointegration of dental implants with an antimicrobial peptide coating.
Chen, X; Zhou, X C; Liu, S; Wu, R F; Aparicio, C; Wu, J Y
2017-05-01
This study aimed to evaluate the in vivo osseointegration of implants with hydrophobic antimicrobial GL13K-peptide coating in rabbit femoral condyles by micro-CT and histological analysis. Six male Japanese Rabbits (4 months old and weighing 2.5 kg each) were included in this study. Twelve implants (3.75 mm wide, 7 mm long) were randomly distributed in two groups, with six implants in the experimental group coated with GL13K peptide and six implants in the control group without surface coating. Each implant in the test and the control group was randomly implanted in the left or right side of femoral condyles. On one side randomly-selected of the femur, each rabbit received a drill that was left without implant as control for the natural healing of bone. After 3 weeks of healing radiographic evaluation of the implant sites was taken. After 6 weeks of healing, rabbits were sacrificed for evaluation of the short-term osseointegration of the dental implants using digital radiography, micro-CT and histology analysis. To perform evaluation of osseointegration, implant location and group was double blinded for surgeon and histology/radiology researcher. Two rabbits died of wound infection in sites with non-coated implants 2 weeks after surgery. Thus, at least four rabbits per group survived after 6 weeks of healing. The wounds healed without suppuration and inflammation. No implant was loose after 6 weeks of healing. Radiography observations showed good osseointegration after 3 and 6 weeks postoperatively, which proved that the tissues followed a natural healing process. Micro-CT reconstruction and analysis showed that there was no statistically significant difference (P > 0.05) in volume of bone around the implant between implants coated with GL13K peptide and implants without coating. Histomorphometric analysis also showed that the mineralized bone area was no statistically different (P > 0.05) between implants coated with GL13K peptide and implants without coating. This study demonstrates that titanium dental implants with an antimicrobial GL13K coating enables in vivo implant osseointegration at similar bone growth rates than gold-standard non-coated dental implants up to 6 weeks of implantation in rabbit femurs.
Mizuno, Ryuichi; Asano, Koichiro; Mikami, Shuji; Nagata, Hirohiko; Kaneko, Gou; Oya, Mototsugu
2012-05-01
To elucidate the patterns of interstitial lung disease during everolimus treatment in patients with metastatic renal cell carcinoma, we reviewed seven cases of everolimus-induced interstitial lung disease. Seven patients with metastatic renal cell carcinoma, which continued to progress despite treatment with sunitinib or sorafenib, developed interstitial lung disease after treatment with everolimus. Chest X-ray demonstrated diffuse infiltrates in lung fields, and chest computed tomography showed bilateral reticular and ground-glass opacities. Serum levels of lactate dehydrogenase (7/7), C-reactive protein (6/7), pulmonary surfactant associated protein D (1/7) and Krebs von den Lungen 6 (5/7) were elevated. The bronchoalveolar lavage fluid obtained from four patients with Grade 3 interstitial lung disease showed lymphocytosis. The transbronchial lung biopsy specimens showed interstitial lymphocytic infiltration and septal thickening of alveolar walls. In two cases with mild interstitial lung disease, the everolimus therapy was successfully continued. In four cases with Grade 3 interstitial lung disease, the drug was discontinued and steroid therapy was initiated. Pulmonary symptoms and radiological abnormalities resolved within 2 months. Serum Krebs von den Lungen 6 was elevated compared with baseline in all cases with interstitial lung disease. Some patients who developed mild interstitial lung disease during everolimus treatment could continue to receive the treatment. Even when severe interstitial lung disease developed, withdrawal of the drug and short-term use of high-dose steroids resulted in rapid recovery. Prompt recognition of interstitial lung disease exacerbation as well as exclusion of progressive disease or infection is of primary importance.
Failure analysis of fractured dental zirconia implants.
Gahlert, M; Burtscher, D; Grunert, I; Kniha, H; Steinhauser, E
2012-03-01
The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient histories were compared with fracture incidences to identify the reasons for the failure of the implants. Twelve of these fractured implants had a diameter of 3.25 mm and one implant had a diameter of 4 mm. All fractured implants were located in the anterior side of the maxilla and mandibula. The patient with the fracture of the 4 mm diameter implant was adversely affected by strong bruxism. By failure analysis (SEM), it could be demonstrated that in all cases, mechanical overloading caused the fracture of the implants. Inhomogeneities and internal defects of the ceramic material could be excluded, but notches and scratches due to sandblasting of the surface led to local stress concentrations that led to the mentioned mechanical overloading by bending loads. The present study identified a fracture rate of nearly 10% within a follow-up period of 36.75 months after prosthetic loading. Ninety-two per cent of the fractured implants were so-called diameter reduced implants (diameter 3.25 mm). These diameter reduced implants cannot be recommended for further clinical use. Improvement of the ceramic material and modification of the implant geometry has to be carried out to reduce the failure rate of small-sized ceramic implants. Nevertheless, due to the lack of appropriate laboratory testing, only clinical studies will demonstrate clearly whether and how far the failure rate can be reduced. © 2011 John Wiley & Sons A/S.
Takano, Nami K; Tsutsumi, Takeshi; Suzuki, Hiroshi; Okamoto, Yoshiwo; Nakajima, Toshiaki
2012-02-01
We evaluated whether frequency analysis could detect the development of interstitial fibrosis in rats. SHR/Izm and age-matched WKY/Izm were used. Limb lead II electrocardiograms were recorded. Continuous wavelet transform (CWT) was applied for the time-frequency analysis. The integrated time-frequency power (ITFP) between QRS complexes was measured and compared between groups. The ITFP at low-frequency bands (≤125Hz) was significantly higher in SHR/Izm. The percent change of ITFP showed the different patterns between groups. Prominent interstitial fibrosis with an increase in TIMP-1 mRNA expression was also observed in SHR/Izm. These results were partly reproduced in a computer simulation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Tilted orthodontic micro implants: a photoelastic stress analysis.
Çehreli, Seçil; Özçırpıcı, Ayça Arman; Yılmaz, Alev
2013-10-01
The aim of this study was to examine peri-implant stresses around orthodontic micro implants upon torque-tightening and static load application by quasi-three-dimensional photoelastic stress analysis. Self-tapping orthodontic micro implants were progressively inserted into photoelastic models at 30, 45, 70, and 90 degrees and insertion torques were measured. Stress patterns (isochromatic fringe orders) were recorded by the quasi-three-dimensional photoelastic method using a circular polariscope after insertion and 250 g static force application. Torque-tightening of implants generated peri-implant stresses. Upon insertion, 90 degree placed implants displayed the lowest and homogeneous stress distribution followed by 30, 70, and 45 degree tilted implants. Static loading did not dramatically alter stress fields around the implants tested. The highest alteration in stress distribution was observed for the 90 degree placed implant, while 70 degree tilted implant had the lowest stresses among tilted implants. Torque-tightening of orthodontic micro implants creates a stress field that is not dramatically altered after application of static lateral moderate orthodontic loads, particularly at the cervical region of tilted implants.
Stability and migration of large oxygen clusters in UO(2+x): density functional theory calculations.
Andersson, D A; Espinosa-Faller, F J; Uberuaga, B P; Conradson, S D
2012-06-21
Using ab initio molecular dynamics simulations and nudged elastic band calculations we examine the finite temperature stability, transition pathways, and migration mechanisms of large oxygen clusters in UO(2+x). Here we specifically consider the recently proposed split quad-interstitial and cuboctahedral oxygen clusters. It is shown that isolated cuboctahedral clusters may transform into more stable configurations that are closely linked to the split quad-interstitial. The split quad-interstitial is stable with respect to single interstitials occupying the empty octahedral holes of the UO(2) lattice. In order to better understand discrepancies between theory and experiments, the simulated atomic pair distribution functions for the split quad-interstitial structures are analyzed with respect to the distribution function for U(4)O(9) previously obtained from neutron diffraction data. Our nudged elastic band calculations suggest that the split quad-interstitial may migrate by translating one of its constituent di-interstitial clusters via a barrier that is lower than the corresponding barrier for individual interstitials, but higher than the barrier for the most stable di-interstitial cluster.
Aryal, Madhava P; Nagaraja, Tavarekere N; Brown, Stephen L; Lu, Mei; Bagher-Ebadian, Hassan; Ding, Guangliang; Panda, Swayamprava; Keenan, Kelly; Cabral, Glauber; Mikkelsen, Tom; Ewing, James R
2014-10-01
The distribution of dynamic contrast-enhanced MRI (DCE-MRI) parametric estimates in a rat U251 glioma model was analyzed. Using Magnevist as contrast agent (CA), 17 nude rats implanted with U251 cerebral glioma were studied by DCE-MRI twice in a 24 h interval. A data-driven analysis selected one of three models to estimate either (1) plasma volume (vp), (2) vp and forward volume transfer constant (K(trans)) or (3) vp, K(trans) and interstitial volume fraction (ve), constituting Models 1, 2 and 3, respectively. CA distribution volume (VD) was estimated in Model 3 regions by Logan plots. Regions of interest (ROIs) were selected by model. In the Model 3 ROI, descriptors of parameter distributions--mean, median, variance and skewness--were calculated and compared between the two time points for repeatability. All distributions of parametric estimates in Model 3 ROIs were positively skewed. Test-retest differences between population summaries for any parameter were not significant (p ≥ 0.10; Wilcoxon signed-rank and paired t tests). These and similar measures of parametric distribution and test-retest variance from other tumor models can be used to inform the choice of biomarkers that best summarize tumor status and treatment effects. Copyright © 2014 John Wiley & Sons, Ltd.
Park, Jung-Chul; Baek, Won-Sun; Choi, Seong-Ho; Cho, Kyoo-Sung; Jung, Ui-Won
2017-02-01
The aim of this retrospective study was to determine the clinical and the radiographic outcomes of dental implants placed in elderly people older than 65 years. In total, 902 implants in 346 patients (age: 65-89 years) were followed up for 2-17 years following the implant surgery. The survival rate of these implants was recorded and analyzed. Changes in marginal bone levels were also analyzed in serial radiographs, and Cox regression analysis for implant loss was performed. The survival rates were 95.39% and 99.98% in the implant- and patient-based analyses, respectively (involving a total of 29 implant failures), and the marginal bone loss at the implants was 0.17 ± 0.71 mm (mean ± SD). The number of failures was greatest in patients aged 65-69 years. The Cox regression with shared frailty analysis showed that implant loss was significantly greater in those aged 65-69 years than in those aged 70-74 years (P < 0.05), and it varied between specific implant systems. Within the limitations of this retrospective study, it was concluded that implant therapy can be successfully provided to elderly patients and that age alone does not seem to affect the implant survival rate. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: Report of Task Group 192
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podder, Tarun K., E-mail: tarun.podder@uhhospitals.org; Beaulieu, Luc; Caldwell, Barrett
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the applications of this technology have been in the implantation of seeds in patients with early-stage prostate cancer. Nevertheless, the techniques apply to any clinical site where interstitial brachytherapy is appropriate. In consideration of the rapid developments in this area, the American Association of Physicistsmore » in Medicine (AAPM) commissioned Task Group 192 to review the state-of-the-art in the field of robotic interstitial brachytherapy. This is a joint Task Group with the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO). All developed and reported robotic brachytherapy systems were reviewed. Commissioning and quality assurance procedures for the safe and consistent use of these systems are also provided. Manual seed placement techniques with a rigid template have an estimated in vivo accuracy of 3–6 mm. In addition to the placement accuracy, factors such as tissue deformation, needle deviation, and edema may result in a delivered dose distribution that differs from the preimplant or intraoperative plan. However, real-time needle tracking and seed identification for dynamic updating of dosimetry may improve the quality of seed implantation. The AAPM and GEC-ESTRO recommend that robotic systems should demonstrate a spatial accuracy of seed placement ≤1.0 mm in a phantom. This recommendation is based on the current performance of existing robotic brachytherapy systems and propagation of uncertainties. During clinical commissioning, tests should be conducted to ensure that this level of accuracy is achieved. These tests should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot–clinician and robot–patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.« less
A Retrospective Analysis of Ruptured Breast Implants
Baek, Woo Yeol; Lew, Dae Hyun
2014-01-01
Background Rupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants. Methods We performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone), duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management. Results Forty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case), microfat graft (2 case), removal only (14 case), and follow-up loss (17 case). Conclusions Saline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs. PMID:25396188
[Airway-centered interstitial fibrosis related to exposure to fumes from cleaning products].
Serrano, Mario; Molina-Molina, María; Ramírez, José; Sánchez, Marcelo; Xaubet, Antoni
2006-10-01
Airway-centered interstitial fibrosis is a little known clinical entity that has only recently been described in the literature. Its pathology is characterized by bronchial fibrosis and localized interstitial pulmonary fibrosis around the airways. The disease has been associated with inhalation of a variety of substances, environmental or occupational, organic or inorganic. Clinical signs, radiographic manifestations, and lung function in patients with airway-centered interstitial fibrosis are similar to those of patients with idiopathic interstitial pneumonia. We describe a case of airway-centered interstitial fibrosis related to exposure to fumes from cleaning products.
Gehrke, Sergio Alexandre; da Silva, Ulisses Tavares; Del Fabbro, Massimo
2015-12-01
The purpose of this study was to assess implant stability in relation to implant design (conical vs. semiconical and wide-pitch vs narrow-pitch) using resonance frequency analysis. Twenty patients with bilateral edentulous maxillary premolar region were selected. In one hemiarch, conical implants with wide pitch (group 1) were installed; in the other hemiarch, semiconical implants with narrow pitch were installed (group 2). The implant allocation was randomized. The implant stability quotient (ISQ) was measured by resonance frequency analysis immediately following implant placement to assess primary stability (time 1) and at 90 days after placement (time 2). In group 1, the mean and standard deviation ISQ for time 1 was 65.8 ± 6.22 (95% confidence interval [CI], 55 to 80), and for time 2, it was 68.0 ± 5.52 (95% CI, 57 to 77). In group 2, the mean and standard deviation ISQ was 63.6 ± 5.95 (95% CI, 52 to 78) for time 1 and 67.0 ± 5.71 (95% CI, 58 to 78) for time 2. The statistical analysis demonstrated significant difference in the ISQ values between groups at time 1 (P = .007) and no statistical difference at time 2 (P = .54). The greater primary stability of conical implants with wide pitch compared with semiconical implants with narrow pitch might suggest a preference for the former in case of the adoption of immediate or early loading protocols.
Topkaya, Tolga; Solmaz, Murat Yavuz
2015-07-16
The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pleitez, Miguel; von Lilienfeld-Toal, Hermann; Mäntele, Werner
2012-01-01
Interstitial fluid, i.e. the liquid present in the outermost layer of living cells of the skin between the Stratum corneum and the Stratum spinosum, was analyzed by Fourier transform infrared spectroscopy and by infrared spectroscopy using pulsed quantum cascade infrared lasers with photoacoustic detection. IR spectra of simulated interstitial fluid samples and of real samples from volunteers in the 850-1800cm(-1) range revealed that the major components of interstitial fluid are albumin and glucose within the physiological range, with only traces of sodium lactate if at all. The IR absorbance of glucose in interstitial fluid in vivo was probed in healthy volunteers using a setup with quantum cascade lasers and photoacoustic detection previously described. A variation of blood glucose between approx. 80mg/dl and 250mg/dl in the volunteers was obtained using the standard oral glucose tolerance test (OGT). At two IR wavelengths, 1054cm(-1) and 1084cm(-1), a reasonable correlation between the photoacoustic signal from the skin and the blood glucose value as determined by conventional glucose test sticks using blood from the finger tip was obtained. The infrared photoacoustic glucose signal (PAGS) may serve as the key for a non-invasive glucose measurement, since the glucose content in interstitial fluid closely follows blood glucose in the time course and in the level (a delay of some minutes and a level of approx. 80-90% of the glucose level in blood). Interstitial fluid is present in skin layers at a depth of only 15-50μm and is thus within the reach of mid-IR energy in an absorbance measurement. A non-invasive glucose measurement for diabetes patients based on mid-infrared quantum cascade lasers and photoacoustic detection could replace the conventional measurement using enzymatic test stripes and a drop of blood from the finger tip, thus reducing pain and being a cost-efficient alternative for millions of diabetes patients. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pleitez, Miguel; von Lilienfeld-Toal, Hermann; Mäntele, Werner
2012-01-01
Interstitial fluid, i.e. the liquid present in the outermost layer of living cells of the skin between the Stratum corneum and the Stratum spinosum, was analyzed by Fourier transform infrared spectroscopy and by infrared spectroscopy using pulsed quantum cascade infrared lasers with photoacoustic detection. IR spectra of simulated interstitial fluid samples and of real samples from volunteers in the 850-1800 cm -1 range revealed that the major components of interstitial fluid are albumin and glucose within the physiological range, with only traces of sodium lactate if at all. The IR absorbance of glucose in interstitial fluid in vivo was probed in healthy volunteers using a setup with quantum cascade lasers and photoacoustic detection previously described [11]. A variation of blood glucose between approx. 80 mg/dl and 250 mg/dl in the volunteers was obtained using the standard oral glucose tolerance test (OGT). At two IR wavelengths, 1054 cm -1 and 1084 cm -1, a reasonable correlation between the photoacoustic signal from the skin and the blood glucose value as determined by conventional glucose test sticks using blood from the finger tip was obtained. The infrared photoacoustic glucose signal (PAGS) may serve as the key for a non-invasive glucose measurement, since the glucose content in interstitial fluid closely follows blood glucose in the time course and in the level (a delay of some minutes and a level of approx. 80-90% of the glucose level in blood). Interstitial fluid is present in skin layers at a depth of only 15-50 μm and is thus within the reach of mid-IR energy in an absorbance measurement. A non-invasive glucose measurement for diabetes patients based on mid-infrared quantum cascade lasers and photoacoustic detection could replace the conventional measurement using enzymatic test stripes and a drop of blood from the finger tip, thus reducing pain and being a cost-efficient alternative for millions of diabetes patients.
Kałużny, Jakub J; Grzanka, Dariusz; Wiśniewska, Halina; Niewińska, Alicja; Kałużny, Bartłomiej J; Grzanka, Alina
2012-10-01
The purpose of the study is an analysis of intrascleral drainage vessels formed in rabbits' eyes after non-penetrating deep sclerectomy (NPDS) with absorbable and non-absorbable implants, and comparison to eyes in which surgery was performed without implanted material. NPDS was carried out in 12 rabbits, with implantation of non-absorbable methacrylic hydrogel (N=10 eyes) or absorbable cross-linked sodium hyaluronate (N=6 eyes), or without any implant (N=8 eyes). All the animals were euthanized 1 year after surgery. Twenty-one eyeballs were prepared for light microscopy and 3 were prepared for transmission electron microscope (TEM) analysis. Aqueous humour pathways were stained with ferritin in 6 eyeballs. By light microscopy, small vessels adjacent to the areas of scarring were the most common abnormality. Vessel density was significantly higher in operated sclera compared to normal, healthy tissue, regardless of the type of implant used. The average vessel densities were 2.18±1.48 vessels/mm2 in non-implanted sclera, 2.34±1.69 vessels/mm2 in eyes with absorbable implants, and 3.64±1.78 vessels/mm2 in eyes with non-absorbable implants. Analysis of iron distribution in ferritin-injected eyes showed a positive reaction inside new aqueous draining vessels in all groups. TEM analysis showed that the ultrastructure of new vessels matched the features of the small veins. Aqueous outflow after NPDS can be achieved through the newly formed network of small intrascleral veins. Use of non-absorbable implants significantly increases vessel density in the sclera adjacent to implanted material compared to eyes in which absorbable implants or no implants were used.
[Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].
Azevedo, Cesar R de Farias; Hippert, Eduardo
2002-01-01
This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.
Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification
Hamed, Hamed A.; Marzook, Hamdy A.; Ghoneem, Nahed E.; El–Anwar, Mohamed I.
2018-01-01
AIM: This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS: Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models’ components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). RESULTS: Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. CONCLUSION: It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one. PMID:29531612
Peri-Implant Crevicular Fluid Analysis, Enzymes and Biomarkers: a Systemetic Review
Dursun, Erhan
2016-01-01
ABSTRACT Objectives To review the current understanding of the biomarkers and enzymes associated with different forms peri-implant diseases and how their level changes influence the pathogenesis of the inflammatory diseases around dental implants. Material and Methods An electronic search in two different databases was performed including MEDLINE (PubMed) and EMBASE between 1996 to 2016. Human studies analyse peri-implant crevicular fluid (PICF) biomarker and enzyme levels of implants having peri-implant mucositis and peri-implantitis published in English language, were evaluated. A systematic review was performed to assess which biomarkers and enzymes in PICF were used to identify the inflammatory conditions around dental implants. Results Fifty-one articles were identified of which 41 were further evaluated and included in the analysis. Due to significant heterogeneity between included studies, a meta-analysis could not be performed. Instead, a systematic descriptive review was performed. Conclusions Biomarkers and enzymes in peri-implant crevicular fluid have shown promising results in differentiating from peri-implant disease condition to health. However, due to inconsistent results and acquiring much evidence from cross-sectional studies, additional evidence supported by randomized-controlled trials is needed to validate the links reported. PMID:27833734
Basta, Marten N; Gerety, Patrick A; Serletti, Joseph M; Kovach, Stephen J; Fischer, John P
2015-12-01
Innovative approaches to reconstruction have ushered in an era of breast reconstruction in which direct-to-implant procedures can provide an immediately reconstructed breast. Balancing the benefits against its technical challenges is vital. The authors evaluated the safety and efficacy of using direct-to-implant versus conventional two-stage reconstruction through a systematic meta-analysis. A literature search identified all articles published after 1999 involving prosthetic-based breast reconstruction as a two-stage tissue expander/implant or direct-to-implant technique. The primary outcomes of interest, including implant loss, capsular contracture, reoperation, and infection, were analyzed by means of head-to-head meta-analysis. Thirteen studies involving 5216 breast reconstructions were included. The average patient age was 47.2 ± 1.0 years, the average body mass index was 24.9 ± 0.8 mg/k2, and the average follow-up was 40.8 months. Wound infection, seroma, and capsular contracture risk were similar between groups. However, direct-to-implant reconstruction was associated with a higher risk for skin flap necrosis (OR, 1.43; p = 0.01; I2 = 51 percent) and reoperation (OR, 1.25; p = 0.04; I2 = 43 percent). Ultimately, the risk for implant loss was nearly two-fold higher with direct-to-implant reconstruction compared with tissue expander/implant reconstruction (OR, 1.87; p = 0.04; I2 = 33 percent). Although direct-to-implant and two-stage tissue expander/implant reconstruction are successful approaches, this meta-analysis demonstrates significantly greater risk of flap necrosis and implant failure with direct-to-implant reconstruction. The authors' findings suggest that the critical component of patient selection is judgment of mastectomy flap tissue quality. These findings can enhance the risk counseling process and highlight the need for additional investigations to optimize outcomes.
[Esthetic analysis on immediate single-tooth implant restoration in anterior maxilla].
Li, Shao-wei; Wang, Guo-shi; Sha, Yan-zhi
2015-10-01
To evaluate the esthetic outcomes of immediate single-tooth implant restoration in anterior maxilla with the pink esthetic score (PES). Nine patients were treated with 9 Straumann implants by immediate single-tooth implant restoration in anterior maxilla. Assessment of PES after crown placement at 1 week (baseline) and 6 months after implantation was conducted. Statistical analysis was performed using SPSS 16.0 software package. Nine implants achieved a retention rate of 100%. PES for single-tooth implant was 10.33 ± 1.50 at 1 week and 11.44 ± 0.88 at 6 months after crown placement. The difference was significant(P=0.021). This study indicates that immediate single-tooth implant restoration in anterior maxilla is predictable. Immediate single-tooth implantation can result in good clinical esthetic results in most patients with single-tooth missing in anterior maxilla.
Wegner, Kerstin; Weskott, Katharina; Zenginel, Martha; Rehmann, Peter; Wöstmann, Bernd
2013-01-01
This in vitro study aimed to identify the effects of the implant system, impression technique, and impression material on the transfer accuracy of implant impressions. The null hypothesis tested was that, in vitro and within the parameters of the experiment, the spatial relationship of a working cast to the placement of implants is not related to (1) the implant system, (2) the impression technique, or (3) the impression material. A steel maxilla was used as a reference model. Six implants of two different implant systems (Standard Plus, Straumann; Semados, Bego) were fixed in the reference model. The target variables were: three-dimensional (3D) shift in all directions, implant axis direction, and rotation. The target variables were assessed using a 3D coordinate measuring machine, and the respective deviations of the plaster models from the nominal values of the reference model were calculated. Two different impression techniques (reposition/pickup) and four impression materials (Aquasil Ultra, Flexitime, Impregum Penta, P2 Magnum 360) were investigated. In all, 80 implant impressions for each implant system were taken. Statistical analysis was performed using multivariate analysis of variance. The implant system significantly influenced the transfer accuracy for most spatial dimensions, including the overall 3D shift and implant axis direction. There was no significant difference between the two implant systems with regard to rotation. Multivariate analysis of variance showed a significant effect on transfer accuracy only for the implant system. Within the limits of the present study, it can be concluded that the transfer accuracy of the intraoral implant position on the working cast is far more dependent on the implant system than on the selection of a specific impression technique or material.
X-ray absorption fine structure (XAFS) analysis of titanium-implanted soft tissue.
Uo, Motohiro; Asakura, Kiyotaka; Yokoyama, Atsuro; Ishikawa, Makoto; Tamura, Kazuchika; Totsuka, Yasunori; Akasaka, Tsukasa; Watari, Fumio
2007-03-01
Tissues contacting Ti dental implants were subjected to X-ray absorption fine structure (XAFS) analysis to examine the chemical state of Ti transferred from the placed implant into the surrounding tissue. Nine tissues that contacted pure Ti cover screws for several months were excised in a second surgery whereby healing abutments were set. Six tissues that surrounded implants retrieved due to their failure were also excised. Ti distributions in the excised specimens were confirmed by X-ray scanning analytical microscopy (XSAM), and the specimens were subjected to fluorescence XAFS analysis to determine the chemical states of the low concentrations of Ti in the tissues surrounding Ti dental implants. Ti mostly existed in the metallic state and was considered to be debris derived from the abrasion of implant pieces during implant surgery. Oxidized forms of Ti, such as anatase and rutile, were also detected in a few specimens-and existed in either a pure state or mixed state with metallic Ti. It was concluded that the existence of Ti in the tissue did not cause implant failure. Moreover, the usefulness of XAFS for analysis of the chemical states of rarely contained elements in biological tissue was demonstrated.
Design and optimization of a brachytherapy robot
NASA Astrophysics Data System (ADS)
Meltsner, Michael A.
Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.
Lahoti, Krishnakumar; Pathrabe, Anup; Gade, Jaykumar
2016-01-01
The purpose of this research was to compare stress distribution on the bone between single implant-retained and two-implant-retained mandibular overdentures using three-dimensional (3D) finite element analysis. Two 3D finite element models were designed. The first model included single implant-supported mandibular overdenture placed in the midline of the mandible while the second model included two-implant-supported mandibular overdenture placed in the intra-foramen region, retained by ball attachment of the same diameter. The bone was modeled on the D2 bone depending on the classification given by Misch. A computed tomography scan of the mandible was used to model the bone by plotting the key points on the graph and generating the identical key points on the ANSYS Software (ANSYS, Inc., USA). The implant was modeled using appropriate dimensions as provided by the manufacturer. Stresses were calculated based on the von Mises criteria. Stresses produced in the hard bone (HB) and soft bone (SB) were higher in single implant-retained mandibular overdenture while stresses produced around the denture as well as implant were higher in two-implant-retained mandibular overdenture. Within the limitations of the study, it had been seen that stresses produced were the highest on HB and SB in single implant-retained mandibular overdenture while stresses produced across the denture as well as implant were the highest in two-implant-retained mandibular overdenture.
Papper, S
1980-01-01
There are many causes of interstitial nephritis other than pyelonephritis. The term interstitial nephritis does not connote a single etiologic or pathogenetic mechanism; it rather arbitrarily places together a wider variety of renal diseases that have a predilection for early and major involvement of the renal interstitium. The prototype of acute interstitial nephritis is acute pyelonephritis. In addition, there is a drug-related acute interstitial disease that is probably of immunological nature and usually reverses with discontinuance of the offending drug. Chronic interstitial nephritis includes many diverse illnesses. Nonobstructive pyelonephritis occurs but its prevalence is debated. Analgesic abuse nephropathy is not rare and is potentially reversible. Papillary necrosis has many causes and a wide spectrum of clinical presentations. Heavy metals, such as lead, cause interstitial nephritis. Balkan nephropathy occurs in an endemic area and although not bacterial in origin is of unknown cause.
Balance point characterization of interstitial fluid volume regulation.
Dongaonkar, R M; Laine, G A; Stewart, R H; Quick, C M
2009-07-01
The individual processes involved in interstitial fluid volume and protein regulation (microvascular filtration, lymphatic return, and interstitial storage) are relatively simple, yet their interaction is exceedingly complex. There is a notable lack of a first-order, algebraic formula that relates interstitial fluid pressure and protein to critical parameters commonly used to characterize the movement of interstitial fluid and protein. Therefore, the purpose of the present study is to develop a simple, transparent, and general algebraic approach that predicts interstitial fluid pressure (P(i)) and protein concentrations (C(i)) that takes into consideration all three processes. Eight standard equations characterizing fluid and protein flux were solved simultaneously to yield algebraic equations for P(i) and C(i) as functions of parameters characterizing microvascular, interstitial, and lymphatic function. Equilibrium values of P(i) and C(i) arise as balance points from the graphical intersection of transmicrovascular and lymph flows (analogous to Guyton's classical cardiac output-venous return curves). This approach goes beyond describing interstitial fluid balance in terms of conservation of mass by introducing the concept of inflow and outflow resistances. Algebraic solutions demonstrate that P(i) and C(i) result from a ratio of the microvascular filtration coefficient (1/inflow resistance) and effective lymphatic resistance (outflow resistance), and P(i) is unaffected by interstitial compliance. These simple algebraic solutions predict P(i) and C(i) that are consistent with reported measurements. The present work therefore presents a simple, transparent, and general balance point characterization of interstitial fluid balance resulting from the interaction of microvascular, interstitial, and lymphatic function.
The relevance of light diffusion profiles for interstitial PDT using light-diffusing optical fibers
NASA Astrophysics Data System (ADS)
Stringasci, Mirian D.; Fortunato, Thereza C.; Moriyama, Lilian T.; Vollet Filho, José Dirceu; Bagnato, Vanderlei S.; Kurachi, Cristina
2017-02-01
Photodynamic therapy (PDT) is a technique used for several tumor types treatment. Light penetration on biological tissue is one limiting factor for PDT applied to large tumors. An alternative is using interstitial PDT, in which optical fibers are inserted into tumors. Cylindrical diffusers have been used in interstitial PDT. Light emission of different diffusers depends on the manufacturing process, size and optical properties of fibers, which make difficult to establish an adequate light dosimetry, since usually light profile is not designed for direct tissue-fiber contact. This study discusses the relevance of light distribution by a cylindrical diffuser into a turbid lipid emulsion solution, and how parts of a single diffuser contribute to illumination. A 2 cm-long cylindrical diffuser optical fiber was connected to a diode laser (630 nm), and the light spatial distribution was measured by scanning the solution with a collection probe. From the light field profile generated by a 1 mm-long intermediary element of a 20 mm-long cylindrical diffuser, recovery of light distribution for the entire diffuser was obtained. PDT was performed in rat healthy liver for a real treatment outcome analysis. By using computational tools, a typical necrosis profile generated by the irradiation with such a diffuser fiber was reconstructed. The results showed that it was possible predicting theoretically the shape of a necrosis profile in a healthy, homogeneous tissue with reasonable accuracy. The ability to predict the necrosis profile obtained from an interstitial illumination by optical diffusers has the potential improve light dosimetry for interstitial PDT.
dos Santos, G.C.; Parra, E.R.; Stegun, F.W.; Cirqueira, C.S.; Capelozzi, V.L.
2013-01-01
Idiopathic interstitial pneumonias include complex diseases that have a strong interaction between genetic makeup and environmental factors. However, in many cases, no infectious agent can be demonstrated, and these clinical diseases rapidly progress to death. Theoretically, idiopathic interstitial pneumonias could be caused by the Epstein-Barr virus, cytomegalovirus, adenovirus, hepatitis C virus, respiratory syncytial virus, and herpesvirus, which may be present in such small amounts or such configuration that routine histopathological analysis or viral culture techniques cannot detect them. To test the hypothesis that immunohistochemistry provides more accurate results than the mere histological demonstration of viral inclusions, this method was applied to 37 open lung biopsies obtained from patients with idiopathic interstitial pneumonias. As a result, immunohistochemistry detected measles virus and cytomegalovirus in diffuse alveolar damage-related histological patterns of acute exacerbation of idiopathic pulmonary fibrosis and nonspecific interstitial pneumonia in 38 and 10% of the cases, respectively. Alveolar epithelium infection by cytomegalovirus was observed in 25% of organizing pneumonia patterns. These findings were coincident with nuclear cytopathic effects but without demonstration of cytomegalovirus inclusions. These data indicate that diffuse alveolar damage-related cytomegalovirus or measles virus infections enhance lung injury, and a direct involvement of these viruses in diffuse alveolar damage-related histological patterns is likely. Immunohistochemistry was more sensitive than the histological demonstration of cytomegalovirus or measles virus inclusions. We concluded that all patients with diffuse alveolar damage-related histological patterns should be investigated for cytomegalovirus and measles virus using sensitive immunohistochemistry in conjunction with routine procedures. PMID:24270907
Lasan Trcić, Ruzica; Hitrec, Vlasta; Letica, Ljiljana; Cuk, Mario; Begović, Davor
2003-08-01
Conventional cytogenetics detected an interstitial deletion of proximal region of p-arm of chromosome 2 in a 6-month-old boy with a phenotype slightly resembling Down's syndrome. The deletion was inherited from the father, whose karyotype revealed a small ring-shaped marker chromosome, in addition to interstitial deletion. Fluorescence in situ hybridization identified the marker, which consisted of the proximal region of the p-arm of chromosome 2, including a part of its centromere. This case shows that molecular cytogenetic analysis can reveal the mechanism of the formation of the marker chromosome.
Schellini, Silvana; Jorge, Eliane; Sousa, Roberta; Burroughs, John; El-Dib, Regina
2016-01-01
To assess the efficacy and safety of porous and nonporous implants for management of the anophthalmic socket. Case series meta-analysis was conducted with no language restriction, including studies from: PUBMED, EMBASE and LILACS. Study eligibility criteria were case series design with more than 20 cases reported, use of porous and/or nonporous orbital implants, anophthalmic socket and, treatment success defined as no implant exposure or extrusion. Complications rates from each included study were quantified. Proportional meta-analysis was performed on both outcomes with a random-effects model and the 95% confidential intervals were calculated. A total of 35 case series studies with a total of 3,805 patients were included in the meta-analysis. There are no studies comparing porous and nonporous implants in the anophthalmic socket treatment. There was no statistically significant difference between porous polyethylene (PP) and hydroxyapatite (HA) on implant exposure: 0.026 (0.012-0.045) vs 0.054 (0.041-0.070), respectively and, neither on implant extrusion: 0.0042 (0.0008-0.010) vs. 0.018 (0.004-0.042), respectively. However, there was a significant difference supporting the use of PP when compared to bioceramic implant: 0.026 (0.012 -0.045) vs. 0.12 (0.06-0.20), respectively, on implant exposure. PP implants showed lower chance of exposure than bioceramic implant for anophthalmic socket reconstruction, although we cannot rule out the possibility of heterogeneity bias due to the nature and level of evidence of the included studies. Clinical trials are necessary to expand the knowledge of porous and nonporous orbital implants in the anophthalmic socket management.
Bahrami, Babak; Shahrbaf, Shirin; Mirzakouchaki, Behnam; Ghalichi, Farzan; Ashtiani, Mohammed; Martin, Nicolas
2014-04-01
To investigate, by means of FE analysis, the effect of surface roughness treatments on the distribution of stresses at the bone-implant interface in immediately loaded mandibular implants. An accurate, high resolution, digital replica model of bone structure (cortical and trabecular components) supporting an implant was created using CT scan data and image processing software (Mimics 13.1; Materialize, Leuven, Belgium). An anatomically accurate 3D model of a mandibular-implant complex was created using a professional 3D-CAD modeller (SolidWorks, DassaultSystèmes Solid Works Corp; 2011). Finite element models were created with one of the four roughness treatments on the implant fixture surface. Of these, three were surface treated to create a uniform coating determined by the coefficient of friction (μ); these were either (1) plasma sprayed or porous-beaded (μ=1.0), (2) sandblasted (μ=0.68) or (3) polished (μ=0.4). The fourth implant had a novel two-part surface roughness consisting of a coronal polished component (μ=0.4) interfacing with the cortical bone, and a body plasma treated surface component (μ=1) interfacing with the trabecular bone. Finite element stress analysis was carried out under vertical and lateral forces. This investigation showed that the type of surface treatment on the implant fixture affects the stress at the bone-implant interface of an immediately loaded implant complex. Von Mises stress data showed that the two-part surface treatment created the better stress distribution at the implant-bone interface. The results from this FE computational analysis suggest that the proposed two-part surface treatment for IL implants creates lower stresses than single uniform treatments at the bone-implant interface, which might decrease peri-implant bone loss. Future investigations should focus on mechanical and clinical validation of these FE results. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Comparison of Subgingival and Peri-implant Microbiome in Chronic Periodontitis.
Zhang, Qian; Qin, Xue Yan; Jiang, Wei Peng; Zheng, Hui; Xu, Xin Li; Chen, Feng
2015-09-01
To analyse the microbia composition of 10 healthy dental implants and 10 chronic periodontitis patients. Subgingival plaque and peri-implant biofilm were sampled at the first molar site before and after implant restoration. The analysis was conducted by 454-prosequencing of bacterial V1 to V3 regions of 16S rDNA. Chronic periodontitis subjects showed greater bacterial diversity compared with implant subjects. The relative abundance of sixteen genera and twelve species differed significantly between implant and chronic periodontitis subjects. The genera Catonella, Desulfovibrio, Mogibacterium, Peptostreptococcus and Propionibacterium were present in higher abundance in chronic periodontitis subjects, while implant subjects had higher proportions of Brevundimonas and Pseudomonas species. Our results demonstrate that implant restoration changes the oral microbiota. The analysis suggests that periodontal bacteria can remain for a prolonged period of time at non-dental sites, from where they can colonise the peri-implant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu, Weicheng; National Laboratory for Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083; Hu, Weida, E-mail: wdhu@mail.sitp.ac.cn
2014-11-10
In this paper, we report on the disappearance of the photosensitive area extension effect and the unusual temperature dependence of junction transformation for mid-wavelength, n-on-p HgCdTe photovoltaic infrared detector arrays. The n-type region is formed by B{sup +} ion implantation on Hg-vacancy-doped p-type HgCdTe. Junction transformations under different temperatures are visually captured by a laser beam induced current microscope. A physical model of temperature dependence on junction transformation is proposed and demonstrated by using numerical simulations. It is shown that Hg-interstitial diffusion and temperature activated defects jointly lead to the p-n junction transformation dependence on temperature, and the weaker mixedmore » conduction compared with long-wavelength HgCdTe photodiode contributes to the disappearance of the photosensitive area extension effect in mid-wavelength HgCdTe infrared detector arrays.« less
Current Status and Perspectives of Hyperthermia in Cancer Therapy
NASA Astrophysics Data System (ADS)
Hiraoka, Masahiro; Nagata, Yasushi; Mitsumori, Michihide; Sakamoto, Masashi; Masunaga, Shin-ichiro
2004-08-01
Clinical trials of hyperthermia in combination with radiation therapy or chemotherapy undertaken over the past decades in Japan have been reviewed. Originally developed heating devices were mostly used for these trials, which include RF (radiofrequency) capacitive heating devices, a microwave heating device with a lens applicator, an RF intracavitary heating device, an RF current interstitial heating device, and ferromagnetic implant heating device. Non-randomized trials for various cancers, demonstrated higher response rate in thermoradiotherapy than in radiotherapy alone. Randomized trials undertaken for esophageal cancers also demonstrated improved local response with the combined use of hyperthermia. Furthermore, the complications associated with treatment were not generally serious. These clinical results indicate the benefit of combined treatment of hyperthermia and radiotherapy for various malignancies. On the other hand, the presently available heating devices are not satisfactory from the clinical viewpoints. With the advancement of heating and thermometry technologies, hyperthermia will be more widely and safely used in the treatment of cancers.
Experimental studies of aerosol- cloud droplet interactions at the puy de Dome observatory (France)
NASA Astrophysics Data System (ADS)
Laj, P.; Dupuy, R.; Sellegri, K.; Pichon, J.; Fournol, J.; Cortes, L.; Preunkert, S.; Legrand, M.
2001-05-01
The interactions between aerosol particles, gases and cloud droplets were studied at the puy de Dome cloud station (France, 1465 a.s.l.) during winter 2000. The partitioning of gas and aerosol species between interstitial and condensed phases is achieved using a series of instrumentation including a newly developed dual counter-flow virtual impactor (CVI)/ Round jet impactor (RJI) system. The RJI/CVI system, coupled with measurement of cloud microphysical properties, provided direct observation of number and mass partitioning of aerosols under different air mass conditions. Preliminary results from this field experiment allowed for the characterization of size segregated chemical composition of CCNs and of interstitial aerosols by means of gravimetric analysis and ion chromatography. It appears that CCNs are clearly enriched in soluble species as respect to interstitial aerosols. We found evidences of limited growth of Ca2+ - rich coarse particles (>1 μm) that did not form droplets larger than the 5 μm CVI cut-off. The number partitioning of aerosol particles between interstitial and condensed phases clearly depends upon cloud microphysics and aerosol properties and therefore undergoes different behaviour according to air mass origin. However, results cannot be fully explained by diffusion growth alone, in particular for high cloud LWC.
Probing the low-frequency vortex dynamics in a nanostructured superconducting strip
NASA Astrophysics Data System (ADS)
Silva, C. C. de Souza; Raes, B.; Brisbois, J.; Cabral, L. R. E.; Silhanek, A. V.; Van de Vondel, J.; Moshchalkov, V. V.
2016-07-01
We investigate by scanning susceptibility microscopy the response of a thin Pb strip, with a square array of submicron antidots, to a low-frequency ac magnetic field applied perpendicularly to the film plane. By mapping the local permeability of the sample within the field range where vortices trapped by the antidots and interstitial vortices coexist, we observed two distinct dynamical regimes occurring at different temperatures. At a temperature just below the superconducting transition, T /Tc=0.96 , the sample response is essentially dominated by the motion of highly mobile interstitial vortices. However, at a slightly lower temperature, T /Tc=0.93 , the interstitial vortices freeze up leading to a strong reduction of the ac screening length. We propose a simple model for the vortex response in this system which fits well to the experimental data. Our analysis suggests that the observed switching to the high mobility regime stems from a resonant effect, where the period of the ac excitation is just large enough to allow interstitial vortices to thermally hop through the weak pinning landscape produced by random material defects. This argument is further supported by the observation of a pronounced enhancement of the out-of-phase response at the crossover between both dynamical regimes.
Comparative analysis of stress in a new proposal of dental implants.
Valente, Mariana Lima da Costa; de Castro, Denise Tornavoi; Macedo, Ana Paula; Shimano, Antonio Carlos; Dos Reis, Andréa Cândido
2017-08-01
The purpose of this study was to compare, through photoelastic analysis, the stress distribution around conventional and modified external hexagon (EH) and morse taper (MT) dental implant connections. Four photoelastic models were prepared (n=1): Model 1 - conventional EH cylindrical implant (Ø 4.0mm×11mm - Neodent®), Model 2 - modified EH cylindrical implant, Model 3 - conventional MT Conical implant (Ø 4.3mm×10mm - Neodent®) and Model 4 - modified MT conical implant. 100 and 150N axial and oblique loads (30° tilt) were applied in the devices coupled to the implants. A plane transmission polariscope was used in the analysis of fringes and each position of interest was recorded by a digital camera. The Tardy method was used to quantify the fringe order (n), that calculates the maximum shear stress (τ) value in each selected point. The results showed lower stress concentration in the modified cylindrical implant (EH) compared to the conventional model, with application of 150N axial and 100N oblique loads. Lower stress was observed for the modified conical (MT) implant with the application of 100 and 150N oblique loads, which was not observed for the conventional implant model. The comparative analysis of the models showed that the new design proposal generates good stress distribution, especially in the cervical third, suggesting the preservation of bone tissue in the bone crest region. Copyright © 2017 Elsevier B.V. All rights reserved.
Stress Analysis on the Bone Around Five Different Dental Implants
2001-10-25
University of Science and Technology, Tehran, IRAN Abstract- Implantology has a widespread application in dental cases these days. Although the life...System, in Mackinny RV: Endosteal Dental Implant, Mosby Year Book, 1991 [3] Weiss M, Titanium Fiber-Mesh Metal Implant, J. Oral Implantology , 1986...STRESS ANALYSIS ON THE BONE AROUND FIVE DIFFERENT DENTAL IMPLANTS S. M. Rajaai, S. Khorrami-mehr School of mechanical Engineering Iran
Ardighieri, Laura; Zeppernick, Felix; Hannibal, Charlotte G; Vang, Russell; Cope, Leslie; Junge, Jette; Kjaer, Susanne K; Kurman, Robert J; Shih, Ie-Ming
2014-01-01
There is debate as to whether peritoneal implants associated with serous borderline tumours/atypical proliferative serous tumours (SBT/APSTs) of the ovary are derived from the primary ovarian tumour or arise independently in the peritoneum. We analysed 57 SBT/APSTs from 45 patients with advanced-stage disease identified from a nation-wide tumour registry in Denmark. Mutational analysis for hotspots in KRAS and BRAF was successful in 55 APSTs and demonstrated KRAS mutations in 34 (61.8%) and BRAF mutations in eight (14.5%). Mutational analysis was successful in 56 peritoneal implants and revealed KRAS mutations in 34 (60.7%) and BRAF mutations in seven (12.5%). Mutational analysis could not be performed in two primary tumours and in nine implants, either because DNA amplification failed or because there was insufficient tissue for mutational analysis. For these specimens we performed VE1 immunohistochemistry, which was shown to be a specific and sensitive surrogate marker for a V600E BRAF mutation. VE1 staining was positive in one of two APSTs and seven of nine implants. Thus, among 63 implants for which mutation status was known (either by direct mutational analysis or by VE1 immunohistochemistry), 34 (53.9%) had KRAS mutations and 14 (22%) had BRAF mutations, of which identical KRAS mutations were found in 34 (91%) of 37 SBT/APST–implant pairs and identical BRAF mutations in 14 (100%) of 14 SBT/APST–implant pairs. Wild-type KRAS and BRAF (at the loci investigated) were found in 11 (100%) of 11 SBT/APST–implant pairs. Overall concordance of KRAS and BRAF mutations was 95% in 59 of 62 SBT/APST–implant (non-invasive and invasive) pairs (p < 0.00001). This study provides cogent evidence that the vast majority of peritoneal implants, non-invasive and invasive, harbour the identical KRAS or BRAF mutations that are present in the associated SBT/APST, supporting the view that peritoneal implants are derived from the primary ovarian tumour. PMID:24307542
Takada, Toshinori; Moriyama, Hiroshi; Suzuki, Eiichi
2014-01-01
Occupational and environmental lung diseases are a group of pulmonary disorders caused by inhalation of harmful particles, mists, vapors or gases. Mineralogical analysis is not generally required in the diagnosis of most cases of these diseases. Apart from minerals that are encountered rarely or only in specific occupations, small quantities of mineral dusts are present in the healthy lung. As such when mineralogical analysis is required, quantitative or semi-quantitative methods must be employed. An electron probe microanalyzer with wavelength dispersive spectrometer (EPMA-WDS) enables analysis of human lung tissue for deposits of elements by both qualitative and semi-quantitative methods. Since 1993, we have analyzed 162 cases of suspected occupational and environmental lung diseases using an EPMA-WDS. Our institute has been accepting online requests for elemental analysis of lung tissue samples by EPMA-WDS since January 2011. Hard metal lung disease is an occupational interstitial lung disease that primarily affects workers exposed to the dust of tungsten carbide. The characteristic pathological findings of the disease are giant cell interstitial pneumonia (GIP) with centrilobular fibrosis, surrounded by mild alveolitis with giant cells within the alveolar space. EPMA-WDS analysis of biopsied lung tissue from patients with GIP has demonstrated that tungsten and/or cobalt is distributed in the giant cells and centrilobular fibrosing lesion in GIP. Pneumoconiosis, caused by amorphous silica, and acute interstitial pneumonia, associated with the giant tsunami, were also elementally analyzed by EPMA-WDS. The results suggest that commonly found elements, such as silicon, aluminum, and iron, may cause occupational and environmental lung diseases. Copyright © 2013 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Horino, Taro; Matsumoto, Tatsuki; Inoue, Kosuke; Ichii, Osamu; Terada, Yoshio
2018-05-01
Sarcoidosis affects multiple organs including lung, heart and kidney. Sarcoidosis causes hypercalcemia, hypergammaglobulinemia, and rarely, granulomatous interstitial nephritis, resulting in renal stromal damage. Granulomatous interstitial nephritis is characterized as interstitial nephritis with noncaseating epithelioid granulomas. Diagnosing granulomatous interstitial nephritis before patient's death is challenging; hence, only few cases proven by renal biopsy have been reported till date. We present a case of acute kidney injury caused by granulomatous interstitial nephritis as a renal manifestation of sarcoidosis proven by renal biopsy, which can be confirmed by 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. Glucocorticoid therapy was helpful for improving and maintaining her renal function over a 6-year period.
Analysis of risk factors for cluster behavior of dental implant failures.
Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann
2017-08-01
Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.
Evolution of anisotropy in bcc Fe distorted by interstitial boron
NASA Astrophysics Data System (ADS)
Gölden, Dominik; Zhang, Hongbin; Radulov, Iliya; Dirba, Imants; Komissinskiy, Philipp; Hildebrandt, Erwin; Alff, Lambert
2018-01-01
The evolution of magnetic anisotropy in bcc Fe as a function of interstitial boron atoms was investigated in thin films grown by molecular beam epitaxy. The thermodynamic nonequilibrium conditions during film growth allowed one to stabilize an interstitial boron content of about 14 at .% accompanied by lattice tetragonalization. The c /a ratio scaled linearly with the boron content up to a maximum value of 1.05 at 300 °C substrate growth temperature, with a room-temperature magnetization of. In contrast to nitrogen interstitials, the magnetic easy axis remained in-plane with an anisotropy of approximately -5.1 ×106erg /cm3 . Density functional theory calculations using the measured lattice parameters confirm this value and show that boron local ordering indeed favors in-plane magnetization. Given the increased temperature stability of boron interstitials as compared to nitrogen interstitials, this study will help to find possible ways to manipulate boron interstitials into a more favorable local order.
Brizuela-Velasco, Aritza; Álvarez-Arenal, Ángel; Gil-Mur, Francisco Javier; Herrero-Climent, Mariano; Chávarri-Prado, David; Chento-Valiente, Yelko; Dieguez-Pereira, Markel
2015-10-01
To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An "ad hoc" acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 μm and an image analysis program. Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.
Color Analysis of Periimplant Soft Tissues Focusing on Implant System: A Case Series.
Varoni, Elena M; Moltrasio, Giuseppe; Gargano, Marco; Ludwig, Nicola; Lodi, Giovanni; Scaringi, Riccardo
2017-04-01
To assess the impact of implant system on color harmonization of periimplant mucosa. In this case series, color of periimplant mucosa was compared with color of natural tooth gingiva. Seventeen intercanine implants were analyzed (11 bone level [BL], 6 tissue level [TL] implants). Colorimetric data, at 2, 4, and 6 mm from gingival margin, were collected through fiber optics reflectance spectroscopy, and color differences calculated as ΔE. Dentists, dental students, and lay people, in blind, performed an additional visual color analysis on clinical images. Independently from implant system, the color of periimplant mucosa was significantly different from gingiva (ΔE = 8.2 ± 0.7), resulting darker at L* comparison (P ≤ 0.05). TL periimplant mucosa showed higher ΔE than BL (9.0 ± 1.0 vs 6.6 ± 0.8, respectively; P ≤ 0.05). Observers correctly identified where the implant was placed in about half of the cases, with no significant difference between implant systems. Within the limitations of this study, the color of periimplant soft tissues appears different from gingiva, at spectroscopic analysis. Color discrepancy results higher in the presence of TL implants than in BL implants, although the difference may not be clinically significant.
Fazel, Akbar; Aalai, Shima; Rismanchian, Mansour
2009-08-01
Macro-design influences the initial stability of implant and reduces micromotions. The aim of this study was to determine and compare micromotions and stress distribution in the bone around immediately loaded Maestro and Xive implants using finite element analysis. In this experimental study, accurate, clear photos were prepared of Xive and Maestro implants 12 and 13 mm long and 4 and 3.8 mm in diameter, respectively, using a Nikon Digital Camera with a resolution 5.24-megapixels with 8x Optical Zoom and 4x Digital Zoom. After accurate measurements, 3-D models of the implants inside the lower mandible (D2) were processed in Solidworks Version 2003 environment and transferred into Ansys for finite element analysis. After loading of 500 N angled at 70 degrees from the horizontal plane, the micromotion of the implant and Von Misses stresses around the bone were measured. The measured micromotion in Maestro implant was 148 mum and that in Xive was 284 mum. Stress distribution in the bone surrounding Maestro implant was better than Xive, but maximum stress surrounding Xive implants (30 MPa) was lower than Maestro (33 MPa). Based on the results obtained in the present study, maximum micromotion in maestro was less than that in Xive implants. This finding can guarantee the application of maestro implants for immediate loading.
Solberg, K; Heinemann, F; Pellikaan, P; Keilig, L; Stark, H; Bourauel, C; Hasan, I
2017-05-01
The effect of implants' number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits.
Chylothorax in dermatomyositis complicated with interstitial pneumonia.
Isoda, Kentaro; Kiboshi, Takao; Shoda, Takeshi
2017-04-01
Chylothorax is a disease in which chyle leaks and accumulates in the thoracic cavity. Interstitial pneumonia and pneumomediastinum are common thoracic manifestations of dermatomyositis, but chylothorax complicated with dermatomyositis is not reported. We report a case of dermatomyositis with interstitial pneumonia complicated by chylothorax. A 77-year-old woman was diagnosed as dermatomyositis with Gottron's papules, skin ulcers, anti-MDA5 antibody and rapid progressive interstitial pneumonia. Treatment with betamethasone, tacrolimus and intravenous high-dose cyclophosphamide was initiated, and her skin symptoms and interstitial pneumonia improved once. However, right-sided chylothorax began to accumulate and gradually increase, and at the same time, her interstitial pneumonia began to exacerbate, and skin ulcers began to reappear on her fingers and auricles. Although her chylothorax improved by fasting and parenteral nutrition, she died due to further exacerbations of dermatomyositis and interstitial pneumonia in spite of steroid pulse therapy, increase in the betamethasone dosage, additional intravenous high-dose cyclophosphamide and plasma pheresis. An autopsy showed no lesions such as malignant tumors in the thoracic cavity. This is the first report of chylothorax complicated by dermatomyositis with interstitial pneumonia.
Farrell, Brad J; Prilutsky, Boris I; Kistenberg, Robert S; Dalton, John F; Pitkin, Mark
2014-01-01
Background Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking. Methods Full-body mechanics of walking in two cats was recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading of implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study. Findings The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4 months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth. Interpretation The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a prosthesis. Future studies with this model will help optimize the implant and prosthesis properties. PMID:24405567
Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin
2015-03-01
We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.
Kellermeier, Markus; Herbolzheimer, Jens; Kreppner, Stephan; Lotter, Michael; Strnad, Vratislav; Bert, Christoph
2017-01-01
Electromagnetic Tracking (EMT) is a novel technique for error detection and quality assurance (QA) in interstitial high dose rate brachytherapy (HDR-iBT). The purpose of this study is to provide a concept for data acquisition developed as part of a clinical evaluation study on the use of EMT during interstitial treatment of breast cancer patients. The stability, accuracy, and precision of EMT-determined dwell positions were quantified. Dwell position reconstruction based on EMT was investigated on CT table, HDR table and PDR bed to examine the influence on precision and accuracy in a typical clinical workflow. All investigations were performed using a precise PMMA phantom. The track of catheters inserted in that phantom was measured by manually inserting a 5 degree of freedom (DoF) sensor while recording the position of three 6DoF fiducial sensors on the phantom surface to correct motion influences. From the corrected data, dwell positions were reconstructed along the catheter's track. The accuracy of the EMT-determined dwell positions was quantified by the residual distances to reference dwell positions after using a rigid registration. Precision and accuracy were investigated for different phantom-table and sensor-field generator (FG) distances. The measured precision of the EMT-determined dwell positions was ≤ 0.28 mm (95th percentile). Stability tests showed a drift of 0.03 mm in the first 20 min of use. Sudden shaking of the FG or (large) metallic objects close to the FG degrade the precision. The accuracy with respect to the reference dwell positions was on all clinical tables < 1 mm at 200 mm FG distance and 120 mm phantom-table distance. Phantom measurements showed that EMT-determined localization of dwell positions in HDR-iBT is stable, precise, and sufficiently accurate for clinical assessment. The presented method may be viable for clinical applications in HDR-iBT, like implant definition, error detection or quantification of uncertainties. Further clinical investigations are needed. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Smoking-related interstitial lung diseases.
Caminati, A; Graziano, P; Sverzellati, N; Harari, S
2010-12-01
In pulmonary pathology, a wide spectrum of morphological changes is related to the consequences of smoking, and recognizing them on surgical specimens and on small transbronchial biopsies represents a challenge for the pathologist. Respiratory bronchiolitis, also referred to as smoker's bronchiolitis, is a common histologic feature found in the lung tissue of cigarette smokers. When identified as the sole histopathologic finding in the clinical setting of symptomatic interstitial lung disease, a diagnosis of respiratory bronchiolitis-interstitial lung disease is made. Since smoking is recognized to cause a variety of histologic patterns encompassing respiratory bronchiolitis, respiratory bronchiolitis-interstitial lung disease, desquamative interstitial pneumonia and pulmonary Langerhans cell hystiocytosis, smoking-related interstitial lung disease may be a useful concept to keep in mind for the pathologists. The relationship of smoking with each of these entities has been largely established on the basis of epidemiologic evidence. Although they have been retained as distinct and separate conditions in various classifications of interstitial lung diseases, these entities share a number of clinical, radiologic, and pathologic features suggesting that they represent a spectrum of patterns of interstitial lung disease occurring in predisposed individuals who smoke. Evaluation of histologic features, particularly in surgical lung biopsy samples, is important in making the distinction between these disorders. However, even after tissue biopsy, it may sometimes be difficult to clearly separate these entities. Recently, respiratory bronchiolitis-interstitial lung disease with fibrosis has been described and postulated that this is a smoking-related condition distinct from fibrotic non-specific interstitial pneumonia.
Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock
2012-01-01
The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.
Hu, Wei; Zhao, Qing-yan; Yu, Sheng-bo; Sun, Bin; Chen, Liao; Cao, Sheng; Guo, Rui-qiang
2014-11-22
The purpose of this study was to investigate whether transcatheter renal sympathetic denervation (RSD) interfere with the development of left ventricular (LV) mechanical dyssynchrony during the progression of heart failure (HF). Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (seven dogs), and RSD group (six dogs). Sham-operated group were implanted with pacemakers without pacing; Control group were implanted with pacemakers and underwent 3 weeks of rapid right ventricular pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Both LV strain and LV dyssynchrony were analyzed via 2D speckle-tracking strain echocardiography to evaluate LV function. Longitudinal dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain on apical 4- and 2-chamber views. Radial and circumferential dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain in mid- and base-LV short-axis views. Each myocardial function was also evaluated by averaging the peak systolic strains. LV systolic pressure (LVSP) and LV end-diastolic pressure (LVEDP) were measured. The LV interstitial fibrosis was determined by histological analysis. Plasma angiotensin II (Ang II), aldosterone and norepinephrine (NE) levels were also measured. After 3 weeks, all of the dogs in both the control and RSD groups showed greater LV end-diastolic volume compared with the sham-operated group; however, the dogs in the RSD group had a higher LV ejection fraction (LVEF) than the dogs in the control group (p<0.001). The LV systolic strains were higher in the RSD group than in the control group (p<0.001 for longitudinal, circumferential and radial strain, respectively). The levels of LV dyssynchrony were lower in the RSD group than in the control group (p<0.001 for longitudinal, circumferential and radial dyssynchrony, respectively). Compared with dogs with control alone, RSD dogs had lower LV end-diastolic pressures and less fibrous tissue. The levels of plasma Ang II, aldosterone and NE were lower in the RSD group than in the control group. RSD inhibites the development of left ventricular mechanical dyssynchrony during the progression of heart failure in dogs.
Zarei, Maryam; Jahangirnezhad, Mahmoud; Yousefimanesh, Hojatollah; Robati, Maryam; Robati, Hossein
2018-01-01
Dental implant is a method to replacement of missing teeth. It is important for replacing the missed anterior teeth. In vitro method is a safe method for evaluation of stress distribution. Finite element analysis as an in vitro method evaluated stress distribution around replacement of six maxillary anterior teeth implants in three models of maxillary arch. In this in vitro study, using ABAQUS software (Simulia Corporation, Vélizy-Villacoublay, France), implant simulation was performed for reconstruction of six maxillary anterior teeth in three models. Two implants were placed on both sides of the canine tooth region (A model); two implants on both sides of the canine tooth region and another on one side of the central incisor region (B model); and two implants on both sides of the canine tooth region and two implants in the central incisor area (C model). All implants evaluated in three arch forms (tapered, ovoid, and square). Data were analyzed by finite analysis software. Von Mises stress by increasing of implant number was reduced. In a comparison of A model in each maxillary arch, the stress created in the cortical and cancellous bones in the square arch was less than ovoid and tapered arches. The stress created in implants and cortical and cancellous bones in C model was less than A and B models. The C model (four-implant) reduced the stress distribution in cortical and cancellous bones, but this pattern must be evaluated according to arch form and cost benefit of patients.
Biomaterial-host interactions: consequences, determined by implant retrieval analysis.
Kaplan, S S
1994-01-01
Prosthetic biomaterials have had a profound impact on reconstructive surgery but complete biocompatability remains illusive. This review considers the retrieval analysis of four common prosthetic structures: the hip, the knee, heart valves, and blood vessels. We show that despite a fine record of early success, deterioration due to mechanical failure or deleterious host responses to the implant may compromise long term function. The eventual retrieval and detailed analysis of implanted structures provides an invaluable opportunity to determine the characteristics of implant success or failure and to provoke the development of still better materials.
Clinical outcomes of implant therapy in ectodermal dysplasia patients: a systematic review.
Wang, Y; He, J; Decker, A M; Hu, J C; Zou, D
2016-08-01
The purpose of this review was to determine the outcome of oral function reconstruction in ectodermal dysplasia (ED) patients who have received dental implant therapy. A search was made of the PubMed and Web of Science databases; key words used were "(ectodermal dysplasia) AND (implant OR implants)", with supplementary retrieval key words "dental implant", "zygomatic implant", "anodontia", and "edentulous". Patient age, use of bone graft, implant site, type of implant, and survival rate of the implants were included in the subsequent data analysis. Forty-five articles published between 1988 and October 2015 were included in this analysis. The cases of a total of 96 patients were retrieved (22 children and 74 adults); these patients received a total of 701 implants. Fourteen implants were removed during a median follow-up time of 24 months. The 24-month implant survival rate was 97.9% in adult subjects and 98.6% in children. Sixty-eight percent of adult patients underwent bone augmentation prior to implant placement. Based on this review, dental implants are commonly used in the oral reconstruction of ED patients. However, long-term data on bone augmentation and implant success are needed, as well as additional clinical evidence on bone resorption, the esthetic outcomes of implant therapy, and physiological considerations in ED patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Nagaraja, Tavarekere N; Elmghirbi, Rasha; Brown, Stephen L; Schultz, Lonni R; Lee, Ian Y; Keenan, Kelly A; Panda, Swayamprava; Cabral, Glauber; Mikkelsen, Tom; Ewing, James R
2017-12-01
The objective was to study temporal changes in tumor vascular physiological indices in a period of 24h in a 9L gliosarcoma rat model. Fischer-344 rats (N=14) were orthotopically implanted with 9L cells. At 2weeks post-implantation, they were imaged twice in a 24h interval using dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). Data-driven model-selection-based analysis was used to segment tumor regions with varying vascular permeability characteristics. The region with the maximum number of estimable parameters of vascular kinetics was chosen for comparison across the two time points. It provided estimates of three parameters for an MR contrast agent (MRCA): i) plasma volume (v p ), ii) forward volumetric transfer constant (K trans ) and interstitial volume fraction (v e , ratio of K trans to reverse transfer constant, k ep ). In addition, MRCA extracellular distribution volume (V D ) was estimated in the tumor and its borders, along with tumor blood flow (TBF) and peritumoral MRCA flux. Descriptors of parametric distributions were compared between the two times. Tumor extent was examined by hematoxylin and eosin (H&E) staining. Picrosirus red staining of secreted collagen was performed as an additional index for 9L cells. Test-retest differences between population summaries for any parameter were not significant (paired t and Wilcoxon signed rank tests). Bland-Altman plots showed no apparent trends between the differences and averages of the test-retest measures for all indices. The intraclass correlation coefficients showed moderate to almost perfect reproducibility for all of the parameters, except v p . H&E staining showed tumor infiltration in parenchyma, perivascular space and white matter tracts. Collagen staining was observed along the outer edges of main tumor mass. The data suggest the relative stability of these MR indices of tumor microenvironment over a 24h duration in this gliosarcoma model. Copyright © 2017. Published by Elsevier Inc.
Cochlear implantation in adults: a systematic review and meta-analysis.
Gaylor, James M; Raman, Gowri; Chung, Mei; Lee, Jounghee; Rao, Madhumathi; Lau, Joseph; Poe, Dennis S
2013-03-01
Sensorineural hearing loss is the third leading cause of years lived with disability worldwide. Cochlear implants may provide a viable alternative to hearing aids for this type of hearing loss. The Coverage and Analysis Group at the Centers for Medicare & Medicaid Services was interested in an evaluation of recently published literature on this topic. In addition, this meta-analysis is to our knowledge the first to evaluate quality-of-life (QOL) outcomes in adults with cochlear implants. To evaluate the communication-related outcomes and health-related QOL outcomes after unilateral or bilateral cochlear implantation in adults with sensorineural hearing loss. MEDLINE, Cochrane Central Register of Controlled Trials, Scopus, and previous reports from January 1, 2004, through May 31, 2012. Published studies of adult patients undergoing unilateral or bilateral procedures with multichannel cochlear implants and assessments using open-set sentence tests, multisyllable word tests, or QOL measures. Five researchers extracted information on population characteristics, outcomes of interest, and study design and assessed the studies for risk of bias. Discrepancies were resolved by consensus. A total of 42 studies met the inclusion criteria. Most unilateral implant studies showed a statistically significant improvement in mean speech scores as measured by open-set sentence or multisyllable word tests; meta-analysis revealed a significant improvement in QOL after unilateral implantation. Results from studies assessing bilateral implantation showed improvement in communication-related outcomes compared with unilateral implantation and additional improvements in sound localization compared with unilateral device use or implantation only. Based on a few studies, the QOL outcomes varied across tests after bilateral implantation. Unilateral cochlear implants provide improved hearing and significantly improve QOL, and improvements in sound localization are noted for bilateral implantation. Future studies of longer duration, higher-quality reporting, and large databases or registries of patients with long-term follow-up data are needed to yield stronger evidence.
The effects of implant angulation on the resonance frequency of a dental implant.
Harirforoush, R; Arzanpour, S; Chehroudi, B
2014-08-01
Dental implants are ideally placed in an orientation that allows vertical transfer of occlusal forces along their long axis. Nevertheless, optimal situations for implant placement are seldom encountered resulting in implants placement in angulated positions, which may affect their long-term success. The resonance frequency (RF) is an objective tool used to monitor stability of the implant tissue integration; however, little is known of the effect of the implant orientation in bone on the RF and its potential significance. The purpose of this research was to determine the relation between the dental implant orientation and the corresponding RF of implant. Three-dimensional (3D) modelling software was used to construct a 3D model of a pig mandible from computed tomography (CT) images. The RF of the implant was analysed using finite element (FE) modal analysis in software ANSYS (v.12). In addition, a cubical model was also developed in MIMICS to investigate the parameters affecting the relationship between RF and implant orientation in a simplified environment. The orientation angle was increased from 0 to 10 degrees in 1 degree increments and the resulting RF was analysed using correlation analysis and one-way ANOVA. Our analysis illustrated that the RF fluctuation following altering implant orientation was strongly correlated (r=0.97) with the contacting cortical to cancellous bone ratio (CCBR) at the implant interface. The most extreme RF change (from 9.81kHz to 10.07kHz) occurred when the implant was moved 0.5mm in positive z-direction, which resulted in the maximum change of CCBR from 52.9 to 54.8. Copyright © 2014. Published by Elsevier Ltd.
Structure and interstitial iodide migration in hybrid perovskite methylammonium lead iodide
NASA Astrophysics Data System (ADS)
Minns, J. L.; Zajdel, P.; Chernyshov, D.; van Beek, W.; Green, M. A.
2017-05-01
Hybrid perovskites form an emerging family of exceptional light harvesting compounds. However, the mechanism underpinning their photovoltaic effect is still far from understood, which is impeded by a lack of clarity on their structures. Here we show that iodide ions in the methylammonium lead iodide migrate via interstitial sites at temperatures above 280 K. This coincides with temperature dependent static distortions resulting in pseudocubic local symmetry. Based on bond distance analysis, the migrating and distorted iodines are at lengths consistent with the formation of I2 molecules, suggesting a 2I--->I2+2e- redox couple. The actual formula of this compound is thus (CH3NH3)PbI3-2x(I2)x where x~0.007 at room temperature. A crucial feature of the tetragonal structure is that the methylammonium ions do not sit centrally in the A-site cavity, but disordered around two off-centre orientations that facilitate the interstitial ion migration via a gate opening mechanism.
Characterization of Oxygen Defect Clusters in UO2+ x Using Neutron Scattering and PDF Analysis.
Ma, Yue; Garcia, Philippe; Lechelle, Jacques; Miard, Audrey; Desgranges, Lionel; Baldinozzi, Gianguido; Simeone, David; Fischer, Henry E
2018-06-18
In hyper-stoichiometric uranium oxide, both neutron diffraction work and, more recently, theoretical analyses report the existence of clusters such as the 2:2:2 cluster, comprising two anion vacancies and two types of anion interstitials. However, little is known about whether there exists a region of low deviation-from-stoichiometry in which defects remain isolated, or indeed whether at high deviation-from-stoichiometry defect clusters prevail that contain more excess oxygen atoms than the di-interstitial cluster. In this study, we report pair distribution function (PDF) analyses of UO 2 and UO 2+ x ( x ≈ 0.007 and x ≈ 0.16) samples obtained from high-temperature in situ neutron scattering experiments. PDF refinement for the lower deviation from stoichiometry sample suggests the system is too dilute to differentiate between isolated defects and di-interstitial clusters. For the UO 2.16 sample, several defect structures are tested, and it is found that the data are best represented assuming the presence of center-occupied cuboctahedra.
Alagille syndrome with deletion 20p12.2-p12.3 and hypoplastic left heart.
Robert, Marie Leema P; Lopez, Tony; Crolla, John; Huang, Shuwen; Owen, Carol; Burvill-Holmes, Lisa; Stumper, Oliver; Turnpenny, Peter D
2007-10-01
We report a male patient born at 37-weeks gestation, weighing 1.885 kg (<0.4th centile). Shortly after birth, he was diagnosed with hypoplastic left heart syndrome for which he underwent a Norwood procedure. Subsequently, he developed problems with failure to thrive and developmental delay. At the age of 4 years his delay in growth and development led to further investigations, which revealed a small de-novo interstitial deletion of chromosome 20p12.2. JAGGED1 haploinsufficiency was confirmed by fluorescence in situ hybridization. Array-comparative genomic hybridization analysis confirmed and quantified an approximate 5.4 Mb interstitial deletion involving the chromosomal region 20p12.2-p12.3. This precise interstitial deletion has not been previously reported. Further clinical evaluation revealed posterior embryotoxon and butterfly vertebrae. He has normal liver function tests, facial features consistent with Alagille syndrome, and mild learning difficulties. To our knowledge this is the first report of Alagille syndrome associated with hypoplastic left heart syndrome.
Huang, Shengsong; Qin, Yu; Chen, Yingna; Pan, Jing; Xu, Chengdang; Wu, Denglong; Chao, Wan-Yu; Wei, John T; Tomlins, Scott A; Wang, Xueding; Brian Fowlkes, J; Carson, Paul L; Cheng, Qian; Xu, Guan
2018-06-23
Transrectal ultrasound (TRUS) guided biopsy is the standard procedure for evaluating the presence and aggressiveness of prostate cancer. TRUS biopsy involves tissue removal, and suffers from low core yield as well as high false negative rate. A less invasive and more accurate diagnostic procedure for prostate cancer is therefore highly desired. Combining the optical sensitivity and ultrasonic resolution to resolve the spatial distribution of the major molecular components in tissue, photoacoustic (PA) technology could be an alternative approach for the diagnosis of prostate cancer. The purpose of this study is to examine the feasibility of identifying aggressive prostate cancer using interstitial PA measurements. 17 patients with pre-biopsy magnetic resonance imaging (MRI), TRUS biopsies and planned prostatectomies were enrolled in this study. The interstitial PA measurements were achieved using our recently developed needle PA probe, which was inserted into the ex vivo prostates in the fashion of a biopsy needle. A total of 70 interstitial PA measurements were acquired. The PA measurements were quantified by a previously established PA physio-chemical analysis (PAPCA) method. The histology has confirmed the nonaggressive and aggressive cancerous conditions at the insertion locations. The diagnostic accuracy was also compared to that provided by the pre-biopsy MRI. The quantitative study shows significant differences between the individual parameters of the nonaggressive and the aggressive cancerous regions (p<0.005). Multivariate analysis of the quantitative features achieved a diagnostic accuracy of 78.6% for differentiating nonaggressive and aggressive prostate cancer tissues CONCLUSIONS: The proposed procedure has shown promises in the diagnosis of aggressive prostate cancer. This article is protected by copyright. All rights reserved.
Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.
Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L
2017-11-01
From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Cannula Implantation into the Cisterna Magna of Rodents.
Xavier, Anna L R; Hauglund, Natalie Linea; von Holstein-Rathlou, Stephanie; Li, Qianliang; Sanggaard, Simon; Lou, Nanhong; Lundgaard, Iben; Nedergaard, Maiken
2018-05-23
Cisterna magna cannulation (CMc) is a straightforward procedure that enables direct access to the cerebrospinal fluid (CSF) without operative damage to the skull or the brain parenchyma. In anesthetized rodents, the exposure of the dura mater by blunt dissection of the neck muscles allows the insertion of a cannula into the cisterna magna (CM). The cannula, composed either by a fine beveled needle or borosilicate capillary, is attached via a polyethylene (PE) tube to a syringe. Using a syringe pump, molecules can then be injected at controlled rates directly into the CM, which is continuous with the subarachnoid space. From the subarachnoid space, we can trace CSF fluxes by convective flow into the perivascular space around penetrating arterioles, where solute exchange with the interstitial fluid (ISF) occurs. CMc can be performed for acute injections immediately following the surgery, or for chronic implantation, with later injection in anesthetized or awake, freely moving rodents. Quantitation of tracer distribution in the brain parenchyma can be performed by epifluorescence, 2-photon microscopy, and magnetic resonance imaging (MRI), depending on the physico-chemical properties of the injected molecules. Thus, CMc in conjunction with various imaging techniques offers a powerful tool for assessment of the glymphatic system and CSF dynamics and function. Furthermore, CMc can be utilized as a conduit for fast, brain-wide delivery of signaling molecules and metabolic substrates that could not otherwise cross the blood brain barrier (BBB).
Shaoki, Algabri; Xu, Jia-Yun; Sun, Haipeng; Chen, Xian-Shuai; Ouyang, Jianglin; Zhuang, Xiu-Mei; Deng, Fei-Long
2016-10-27
The selective laser melting (SLM) technique is a recent additive manufacturing (AM) technique. Several studies have reported success in the SLM-based production of biocompatible orthopaedic implants and three-dimensional bone defect constructs. In this study, we evaluated the surface properties and biocompatibility of an SLM titanium implant in vitro and compared them with those of a machined (MA) titanium control surface. In addition, we evaluated the osseointegration capability of the SLM implants in vivo and compared it with those of MA and Nobel-speedy (Nobel-S) implants. SLM microtopographical surface analysis revealed porous and high roughness with varied geometry compared with a smooth surface in MA Ti samples but with similar favourable wettability. Osteoblast proliferation and alkaline phosphatase activity were significantly enhanced on the SLM surface. Histological analysis of the bone-implant contact ratio revealed no significant difference among SLM, MA, and Nobel-S implants. Micro-CT assessment indicated that there was no significant difference in bone volume fraction around the implant among SLM implants and other types of surface modification implants. The removal torque value measurement of SLM implants was significantly lower that of than Nobel-S implants P < 0.001 and higher than that of MA implants. The study demonstrates the capability of SLM implants to integrate with living bone. The SLM technique holds promise as a new dental implant manufacturing technique.
Sweeney, Lisa M.; Parker, Ann; Haber, Lynne T.; Tran, C. Lang; Kuempel, Eileen D.
2015-01-01
A biomathematical model was previously developed to describe the long-term clearance and retention of particles in the lungs of coal miners. The model structure was evaluated and parameters were estimated in two data sets, one from the United States and one from the United Kingdom. The three-compartment model structure consists of deposition of inhaled particles in the alveolar region, competing processes of either clearance from the alveolar region or translocation to the lung interstitial region, and very slow, irreversible sequestration of interstitialized material in the lung-associated lymph nodes. Point estimates of model parameter values were estimated separately for the two data sets. In the current effort, Bayesian population analysis using Markov chain Monte Carlo simulation was used to recalibrate the model while improving assessments of parameter variability and uncertainty. When model parameters were calibrated simultaneously to the two data sets, agreement between the derived parameters for the two groups was very good, and the central tendency values were similar to those derived from the deterministic approach. These findings are relevant to the proposed update of the ICRP human respiratory tract model with revisions to the alveolar-interstitial region based on this long-term particle clearance and retention model. PMID:23454101
Impairment of the glymphatic system after diabetes.
Jiang, Quan; Zhang, Li; Ding, Guangliang; Davoodi-Bojd, Esmaeil; Li, Qingjiang; Li, Lian; Sadry, Neema; Nedergaard, Maiken; Chopp, Michael; Zhang, Zhenggang
2017-04-01
The glymphatic system has recently been shown to clear brain extracellular solutes and abnormalities in glymphatic clearance system may contribute to both initiation and progression of neurological diseases. Despite that diabetes is known as a risk factor for vascular diseases, little is known how diabetes affects the glymphatic system. The current study is the first investigation of the effect of diabetes on the glymphatic system and the link between alteration of glymphatic clearance and cognitive impairment in Type-2 diabetes mellitus rats. MRI analysis revealed that clearance of cerebrospinal fluid contrast agent Gd-DTPA from the interstitial space was slowed by a factor of three in the hippocampus of Type-2 diabetes mellitus rats compared to the non-DM rats and confirmed by florescence imaging analysis. Cognitive deficits detected by behavioral tests were highly and inversely correlated to the retention of Gd-DTPA contrast and fluorescent tracer in the hippocampus of Type-2 diabetes mellitus rats. Type-2 diabetes mellitus suppresses clearance of interstitial fluid in the hippocampus and hypothalamus, suggesting that an impairment of the glymphatic system contributes to Type-2 diabetes mellitus-induced cognitive deficits. Whole brain MRI provides a sensitive, non-invasive tool to quantitatively evaluate cerebrospinal fluid and interstitial fluid exchange in Type-2 diabetes mellitus and possibly in other neurological disorders, with potential clinical application.
Impairment of the glymphatic system after diabetes
Zhang, Li; Ding, Guangliang; Davoodi-Bojd, Esmaeil; Li, Qingjiang; Li, Lian; Sadry, Neema; Nedergaard, Maiken; Chopp, Michael; Zhang, Zhenggang
2016-01-01
The glymphatic system has recently been shown to clear brain extracellular solutes and abnormalities in glymphatic clearance system may contribute to both initiation and progression of neurological diseases. Despite that diabetes is known as a risk factor for vascular diseases, little is known how diabetes affects the glymphatic system. The current study is the first investigation of the effect of diabetes on the glymphatic system and the link between alteration of glymphatic clearance and cognitive impairment in Type-2 diabetes mellitus rats. MRI analysis revealed that clearance of cerebrospinal fluid contrast agent Gd-DTPA from the interstitial space was slowed by a factor of three in the hippocampus of Type-2 diabetes mellitus rats compared to the non-DM rats and confirmed by florescence imaging analysis. Cognitive deficits detected by behavioral tests were highly and inversely correlated to the retention of Gd-DTPA contrast and fluorescent tracer in the hippocampus of Type-2 diabetes mellitus rats. Type-2 diabetes mellitus suppresses clearance of interstitial fluid in the hippocampus and hypothalamus, suggesting that an impairment of the glymphatic system contributes to Type-2 diabetes mellitus-induced cognitive deficits. Whole brain MRI provides a sensitive, non-invasive tool to quantitatively evaluate cerebrospinal fluid and interstitial fluid exchange in Type-2 diabetes mellitus and possibly in other neurological disorders, with potential clinical application. PMID:27306755
Tey, Wei Keat; Kuang, Ye Chow; Ooi, Melanie Po-Leen; Khoo, Joon Joon
2018-03-01
Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses. This study proposes an automated quantification system for measuring the amount of interstitial fibrosis in renal biopsy images as a consistent basis of comparison among pathologists. The system extracts and segments the renal tissue structures based on colour information and structural assumptions of the tissue structures. The regions in the biopsy representing the interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area and quantified as a percentage of the total area of the biopsy sample. A ground truth image dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated a good correlation in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses due to the uncertainties in human judgement. An automated quantification system for accurately measuring the amount of interstitial fibrosis in renal biopsy images is presented as a consistent basis of comparison among pathologists. The system identifies the renal tissue structures through knowledge-based rules employing colour space transformations and structural features extraction from the images. In particular, the renal glomerulus identification is based on a multiscale textural feature analysis and a support vector machine. The regions in the biopsy representing interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area. The experiments conducted evaluate the system in terms of quantification accuracy, intra- and inter-observer variability in visual quantification by pathologists, and the effect introduced by the automated quantification system on the pathologists' diagnosis. A 40-image ground truth dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated an average error of 9 percentage points in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists involving samples from 70 kidney patients also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. The accuracy of the proposed quantification system has been validated with the ground truth dataset and compared against the pathologists' quantification results. It has been shown that the correlation between different pathologists' estimation of interstitial fibrosis area has significantly improved, demonstrating the effectiveness of the quantification system as a diagnostic aide. Copyright © 2017 Elsevier B.V. All rights reserved.
Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P
2016-01-01
Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.
Olszewski, Waldemar L; Zaleska, Marzanna
2015-10-01
Lymphedema of limbs is caused by partial or total obstruction of lymphatic collectors as a consequence of skin and deep soft tissue inflammation, trauma of soft tissues and bones, lymphadenectomy, and irradiation in cancer therapy. According to the statistics of the World Health Organization, around 300 million people are affected by pathologic edema of limbs. Effective treatment of such large cohorts has been a challenge for centuries. However, none of the conservative and surgical methods applied so far proved to restore the shape and function of limbs to normal conditions. Actually, physiotherapy is the therapy of choice as a main modality or supplementary to surgical procedures divided into two groups: the bridging drainage and excisional techniques. The microsurgical operations can be performed if some parts of the peripheral collecting lymphatics remain patent and partially drain edematous regions. However, in advanced cases of lymphedema, all main lymphatics are obstructed and tissue fluid accumulates in the interstitial spaces, spontaneously forming "blind channels" or "lakes." The only solution would be to create artificial pathways for edema fluid flow away to the nonobstructed regions where absorption of fluid can take place. The aim of this study was to form artificial pathways for edema fluid flow by subcutaneous implantation of silicone tubes placed along the limb from the lower leg to the lumbar or hypogastric region. In a group of 20 patients with obstructive lymphedema of the lower limbs that developed after lymphadenectomy and irradiation of the pelvis because of uterine cancer with unsuccessful conservative therapy, implantation was done, followed by external compression as intermittent pneumatic compression and elastic support of tissues. Postoperative circumference measurements, lymphoscintigraphy, and ultrasonography of tissues were carried out during 2 years of follow-up. There was a fast decrease of calf circumference since the day of implantation during weeks by a mean 3% with stabilization afterward. Patency of tubes and accumulation of fluid around them were seen on ultrasonography and lymphoscintigraphy in all cases. No tissue cellular reaction to silicone tubes was noted. The simplicity of the surgical procedure, decrease of limb edema, and lack of tissue reaction to the implant make the method worth applying in advanced stages of lymphedema with large volumes of accumulated tissue edema fluid. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
2014-01-01
Background Acute interstitial pneumonia is a rare interstitial lung disease that rapidly progresses to respiratory failure or death. Several studies showed that myofibroblast plays an important role in the evolution of diffuse alveolar damage, which is the typical feature of acute interstitial pneumonia. However, no evidence exists whether alveolar epithelial cells are an additional source of myofibroblasts via epithelial-mesenchymal transition in acute interstitial pneumonia. Case presentation In this report, we present a case of acute interstitial pneumonia in a previously healthy 28-year-old non-smoking woman. Chest high-resolution computed tomography scan showed bilateral and diffusely ground-glass opacification. The biopsy was performed on the fifth day of her hospitalization, and results showed manifestation of acute exudative phase of diffuse alveolar damage characterized by hyaline membrane formation. On the basis of the preliminary diagnosis of acute interstitial pneumonia, high-dose glucocorticoid was used. However, this drug showed poor clinical response and could improve the patient’s symptoms only during the early phase. The patient eventually died of respiratory dysfunction. Histological findings in autopsy were consistent with the late form of acute interstitial pneumonia. Conclusions The results in this study revealed that alveolar epithelial cells underwent epithelial-mesenchymal transition and may be an important origin of myofibroblasts in the progression of acute interstitial pneumonia. Conducting research on the transformation of alveolar epithelial cells into myofibroblasts in the lung tissue of patients with acute interstitial pneumonia may be beneficial for the treatment of this disease. However, to our knowledge, no research has been conducted on this topic. PMID:24755111
Fabie, L; Guedj, L; Pichaud, Ch; Fabie, M
2002-11-01
We present a new self-drilling self-tapping dental implant that simplifies the operative technique and optimizes osseointegration. The implant, the instrumentation, and the operative technique are described. An experimental study was conducted in a sheep with pathological and histomorphological analysis at three months. A clinical evaluation was also conducted in 18 patients who had 27 implants. The experimental study demonstrated good quality osseointegration, without bone necrosis. Three sectors were identified. Histomorphometric analysis demonstrated that mean bone contact reached 40% on cancellous bone and 65% on cortical bone. In the clinical series, one implant had to be removed due to a problem with gum healing. All the other implants were well tolerated. The advantage of this new technique is the use of the implant as the drilling instrument. Much time is saved. In addition, the bone-implant contact is better since the bone cavity is exactly adapted to the implant. The risk of bone lesion is reduced due to the smaller number of drillings.
Wijetunge, S; Ratnatunga, N V I; Abeysekera, T D J; Wazil, A W M; Selvarajah, M
2015-01-01
Chronic kidney disease of unknown etiology (CKDU) is endemic among the rural farming communities in several localities in and around the North Central region of Sri Lanka. This is an interstitial type renal disease and typically has an insidious onset and slow progression. This study was conducted to identify the pathological features in the different clinical stages of CKDU. This is a retrospective study of 251 renal biopsies identified to have a primary interstitial disease from regions endemic for CKDU. Pathological features were assessed and graded in relation to the clinical stage. The mean age of those affected by endemic CKDU was 37.3 ± 12.5 years and the male to female ratio was 3.3:1. The predominant feature of stage I disease was mild and moderate interstitial fibrosis; most did not have interstitial inflammation. The typical stage II disease had moderate interstitial fibrosis with or without mild interstitial inflammation. Stage III disease had moderate and severe interstitial fibrosis, moderate interstitial inflammation, tubular atrophy and some glomerulosclerosis. Stage IV disease typically had severe interstitial fibrosis and inflammation, tubular atrophy and glomerulosclerosis. The mean age of patients with stage I disease (27 ± 10.8 years) was significantly lower than those of the other stages. About 79.2%, 55%, 49.1% and 50% in stage I, II, III and IV disease respectively were asymptomatic at the time of biopsy.
Physicochemical and microscopic characterization of implant-abutment joints.
Lopes, Patricia A; Carreiro, Adriana F P; Nascimento, Rubens M; Vahey, Brendan R; Henriques, Bruno; Souza, Júlio C M
2018-01-01
The purpose of this study was to investigate Morse taper implant-abutment joints by chemical, mechanical, and microscopic analysis. Surfaces of 10 Morse taper implants and the correlated abutments were inspected by field emission gun-scanning electron microscopy (FEG-SEM) before connection. The implant-abutment connections were tightened at 32 Ncm. For microgap evaluation by FEG-SEM, the systems were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant-abutment joint. Furthermore, nanoindentation tests and chemical analysis were performed at the implant-abutment joints. Results were statistically analyzed via one-way analysis of variance, with a significance level of P < 0.05. Defects were noticed on different areas of the abutment surfaces. The minimum and maximum size of microgaps ranged from 0.5 μm up to 5.6 μm. Furthermore, defects were detected throughout the implant-abutment joint that can, ultimately, affect the microgap size after connection. Nanoindentation tests revealed a higher hardness (4.2 ± 0.4 GPa) for abutment composed of Ti6Al4V alloy when compared to implant composed of commercially pure Grade 4 titanium (3.2 ± 0.4 GPa). Surface defects produced during the machining of both implants and abutments can increase the size of microgaps and promote a misfit of implant-abutment joints. In addition, the mismatch in mechanical properties between abutment and implant can promote the wear of surfaces, affecting the size of microgaps and consequently the performance of the joints during mastication.
Negotiating Reassurance: Parents' Narratives on Follow-Up after Cochlear Implantation
ERIC Educational Resources Information Center
Bruin, Marieke; Ohna, Stein Erik
2015-01-01
This study presents an analysis of parental experiences on follow-up after cochlear implantation. Data were constructed in semi-structured, individual interviews with the parents of 14 children who use cochlear implants. Drawing on narrative analysis, the study explores parental responses to insecurity concerning children's learning and…
Intravesical NGF Antisense Therapy Using Lipid Nanoparticle for Interstitial Cystitis
2015-10-01
intravesical botulinum toxin type A injec- tions plus hydrodistention with hydrodis- tention alone for the treatment of refractory interstitial cystitis/ painful ...SUPPLEMENTARY NOTES 14. ABSTRACT Interstitial cystitis/bladder pain syndrome (IC/BPS) is a debilitating disorder characterized by persistent pelvic pain ...from an animal efficacy experiment conducted during the previous period. The project is ongoing. 15. SUBJECT TERMS Interstitial cystitis/ painful
In vivo interstitial glucose characterization and monitoring in the skin by ATR-FTIR spectroscopy
NASA Astrophysics Data System (ADS)
Skrebova Eikje, Natalja
2011-03-01
Successful development of real-time non-invasive glucose monitoring would represent a major advancement not only in the treatment and management of patients with diabetes mellitus and carbohydrate metabolism disorders, but also for understanding in those biochemical, metabolic and (patho-)physiological processes of glucose at the molecular level in vivo. Here, ATR-FTIR spectroscopy technique has been challenged not only for in vivo measurement of interstitial glucose levels, but also for their non-invasive molecular qualitative and quantitative comparative characterization in the skin tissue. The results, based on calculated mean values of determined 5 glucose-specific peaks in the glucose-related 1000-1160 cm-1 region, showed intra- and inter-subject differences in interstitial glucose activity levels with their changes at different times and doses of OGTT, while raising questions about the relationships between interstitial and blood glucose levels. In conclusion, the introduction of ATR-FTIR spectroscopy technique has opened up an access to the interstitial fluid space in the skin tissue for interstitial glucose characterization and monitoring in vivo. Though interstitial versus blood glucose monitoring has different characteristics, it can be argued that accurate and precise measurements of interstitial glucose levels may be more important clinically.
Krushinitskaya, Olga; Tønnessen, Tor Inge; Jakobsen, Henrik; Johannessen, Erik
2011-10-15
Continuous surveillance of blood glucose is a prerogative of maintaining a tight glycaemic control in people suffering from diabetes mellitus. Implantable sensor technology offers the potential of conducting direct long term continuous glucose measurements, but current size restrictions and operational challenges have limited their applications. The osmotic sensor utilises diffusion to create a hydrostatic pressure that is independent of sensor operation and power consumption. This permits ultra-low power architectures to be realized with a minimal start-up time in a package suitable for miniaturization. In contrast, osmotic sensors suffer from the inability of their membranes to discriminate between different constituents in blood or the interstitial fluid that are of comparable size to glucose. By implementing an affinity assay based on the competitive bonding between concanavalin A and dextran, the selectivity of the membrane can be transferred to the glucose specific recognition of the affinity assay. The osmotic effect from the physiological levels of several key metabolites and nutritional components has been addressed identifying in particular ethanol, lactate and amino acids as potential interfering constituents. Both ascorbic acid and mannose would have a normal physiological concentration that is too low to be detected. The studies shows that an osmotic glucose sensor equipped with the con A-dextran affinity assay, is able to filter out potential interfering constituents present in blood, plasma and the interstitial fluid yet retaining a pressure that is proportional to glucose only. Copyright © 2011 Elsevier B.V. All rights reserved.
Singh, Deepinder P; Bylund, Kevin C; Matloubieh, Ahmad; Mazloom, Ali; Gray, Alexander; Sidhu, Ravinder; Barrette, Lucille; Chen, Yuhchyau
2015-04-01
To evaluate recurrent vaginal cancer treated with vaginal brachytherapy (VBT) using graphic optimization in patients not amenable to surgery and interstitial brachytherapy (ISBT). We retrospectively reviewed the records of 5 patients with recurrent cancer in the vagina that were deemed not to be good candidates for ISBT implant because of medical reasons. All patients received computed tomography/magnetic resonance imaging (CT/MRI) based evaluation in addition to a detailed clinical examination, and were noted to have recurrent nodules in the vagina with size ranging from 10-25 mm. Four of the 5 patients had recurrent disease in the vaginal apex, whereas one patient had recurrence in the lateral vaginal wall. Subsequently, all patients were treated with external beam radiation therapy (EBRT) followed by multichannel vaginal cylinder (MVC)-based VBT using graphic optimization for shaping the isodose to improve the clinical target volume (CTV) coverage, as well as to spare the organs at risk (OAR). The dose to the bladder and rectum with regard to 0.1 cc, 1 cc, and 2 cc were recorded. Median age of the patients was 78 years (range 58-86 years). Thickness of the lesions before VBT ranged from 6-15 mm. All patients were followed up with MRI at 3 months. All patients but one demonstrated complete clinical/ radiological response of the tumor. No patient had any grade III/IV toxicity at 24 months. MVC-based VBT using graphic optimization is safe and yields favorable results if used judiciously.
Use of cylindrical diffusing fibers as detectors for interstitial tissue spectroscopy
NASA Astrophysics Data System (ADS)
Baran, Timothy M.; Foster, Thomas H.
2015-03-01
Interstitial photodynamic therapy (iPDT) describes the use of implanted optical fibers for delivery of treatment light to activate photosensitizer in regions that can be located deep within the body. Since sensitive healthy structures are often located nearby, this requires careful treatment planning that is dependent on tissue optical properties. Determination of these values usually involves the insertion of additional fibers into the volume, or the use of flat-cleaved optical fibers as both treatment sources and detectors. The insertion of additional fibers is undesirable, and cylindrical diffusers have been shown to offer superior treatment characteristics compared to flat-cleaved fibers. Using cylindrical diffusers as detectors for spectroscopic measurement is therefore attractive. We describe the determination of the detection profile for a particular cylindrical diffuser design and derive the scatterer concentration gradient within the diffuser core. This detection profile is compared to previously characterized diffusers, and is shown to be dependent on the diffuser design. For diffusers with a constant scatterer concentration and distal mirror, the detection profile is localized to the proximal end of the diffusing region. For diffusers with variable scattering concentration along their length and no distal mirror, the detection profile is shown to be more uniform along the diffusing region. We also present preliminary results showing the recovery of optical properties using arrays of cylindrical diffusing fibers as sources and detectors, with a mean error of 4.4% in the determination of μeff. The accuracy of these results is comparable to those obtained with other methods of optical property recovery.
NASA Astrophysics Data System (ADS)
Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf
2017-10-01
For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.
Lee, Robert J; Moon, Won; Hong, Christine
2017-05-01
Bone-borne palatal expansion relies on mini-implant stability for successful orthopedic expansion. The large magnitude of applied force experienced by mini-implants during bone-borne expansion may lead to high failure rates. Use of bicortical mini-implant anchorage rather than monocortical anchorage may improve mini-implant stability. The aims of this study were to analyze and compare the effects of bicortical and monocortical anchorages on stress distribution and displacement during bone-borne palatal expansion using finite element analysis. Two skull models were constructed to represent expansion before and after midpalatal suture opening. Three clinical situations with varying mini-implant insertion depths were studied in each skull model: monocortical, 1-mm bicortical, and 2.5-mm bicortical. Finite element analysis simulations were performed for each clinical situation in both skull models. Von Mises stress distribution and transverse displacement were evaluated for all models. Peri-implant stress was greater in the monocortical anchorage model compared with both bicortical anchorage models. In addition, transverse displacement was greater and more parallel in the coronal plane for both bicortical models compared with the monocortical model. Minimal differences were observed between the 1-mm and the 2.5-mm bicortical models for both peri-implant stress and transverse displacement. Bicortical mini-implant anchorage results in improved mini-implant stability, decreased mini-implant deformation and fracture, more parallel expansion in the coronal plane, and increased expansion during bone-borne palatal expansion. However, the depth of bicortical mini-implant anchorage was not significant. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Earfold Implantable Clip System for Correction of Prominent Ears: Analysis of Safety in 403 Patients
Sojitra, Nilesh; Glumicic, Sinisa; Vlok, Jacobus A.; O’Toole, Greg; Hannan, S. Alam; Sabbagh, Walid
2018-01-01
Background: The Earfold system, a new treatment for the correction of prominent ears, consists of 3 components: the Earfold implant, the Earfold introducer, and the Prefold positioner. Methods: This is an interim report based on an ongoing analysis of safety in a series of patients treated for prominent ears with the Earfold implant between February 2013 and September 2014. Safety was assessed based on adverse event reports and the need for implant revision; follow-up is ongoing. Results: Seven surgeons used 1,200 Earfold implants to treat 403 patients (ages, 7–70 years; 63% male); the time since the initial implant procedure now ranges from 30 to 48 months. To date, 145 patients (36%) have returned for a follow-up visit (mean, 7.7 months [range, 1–34 months]). Adverse events requiring intervention have affected 39 of 403 (9.7%) patients; these include implant revisions (n = 17 [4.2%], most often due to implant visibility), skin erosion over the implant (n = 15 [3.7%]), and infection (n = 7 [1.7%]). Bleeding, recurrence of prominence, hematoma, deformity, or adverse scarring did not occur. Conclusions: This interim analysis has shown that Earfold prominent ear correction system is associated with relatively few adverse events that require intervention; a small number of patients experienced infection, implant extrusion, or implant visibility that required revision. Most adverse events were related to either patient selection or technical errors at implantation. It is expected that with continued use of Earfold by surgeons experienced in otoplasty, the adverse event incidence will decrease. PMID:29464160
Development of implant loading device for animal study about various loading protocol: a pilot study
Yoon, Joon-Ho; Park, Young-Bum; Cho, Yuna; Kim, Chang-Sung; Choi, Seong-Ho; Moon, Hong-Seok; Lee, Keun-Woo
2012-01-01
PURPOSE The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method,simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (µε) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study. PMID:23236575
New insights into canted spiro carbon interstitial in graphite
NASA Astrophysics Data System (ADS)
EL-Barbary, A. A.
2017-12-01
The self-interstitial carbon is the key to radiation damage in graphite moderator nuclear reactor, so an understanding of its behavior is essential for plant safety and maximized reactor lifetime. The density functional theory is applied on four different graphite unit cells, starting from of 64 carbon atoms up to 256 carbon atoms, using AIMPRO code to obtain the energetic, athermal and mechanical properties of carbon interstitial in graphite. This study presents first principles calculations of the energy of formation that prove its high barrier to athermal diffusion (1.1 eV) and the consequent large critical shear stress (39 eV-50 eV) necessary to shear graphite planes in its presence. Also, for the first time, the gamma surface of graphite in two dimensions is calculated and found to yield the critical shear stress for perfect graphite. Finally, in contrast to the extensive literature describing the interstitial of carbon in graphite as spiro interstitial, in this work the ground state of interstitial carbon is found to be canted spiro interstitial.
Obara-Michlewska, Marta; Ding, Fengfei; Popek, Mariusz; Verkhratsky, Alexei; Nedergaard, Maiken; Zielinska, Magdalena; Albrecht, Jan
2018-05-14
Acute toxic liver failure (ATLF) rapidly leads to brain oedema and neurological decline. We evaluated the ability of ATLF-affected brain to control the ionic composition and acid-base balance of the interstitial fluid. ATLF was induced in 10-12 weeks old male C57Bl mice by single intraperitoneal (i.p.) injection of 100 μg/g azoxymethane (AOM). Analyses were carried out in cerebral cortex of precomatous mice 20-24 h after AOM administration. Brain fluid status was evaluated by measuring apparent diffusion coefficient [ADC] using NMR spectroscopy, Evans Blue extravasation, and accumulation of an intracisternally-injected fluorescent tracer. Extracellular pH ([pH] e ) and ([K + ] e ) were measured in situ with ion-sensitive microelectrodes. Cerebral cortical microdialysates were subjected to photometric analysis of extracellular potassium ([K + ] e ), sodium ([Na + ] e ) and luminometric assay of extracellular lactate ([Lac] e ). Potassium transport in cerebral cortical slices was measured ex vivo as 86 Rb uptake. Cerebral cortex of AOM-treated mice presented decreased ADC supporting the view that ATLF-induced brain oedema is primarily cytotoxic in nature. In addition, increased Evans blue extravasation indicated blood brain barrier leakage, and increased fluorescent tracer accumulation suggested impaired interstitial fluid passage. However, [K + ] e , [Na + ] e , [Lac] e , [pH] e and potassium transport in brain of AOM-treated mice was not different from control mice. We conclude that in spite of cytotoxic oedema and deregulated interstitial fluid passage, brain of mice with ATLF retains the ability to maintain interstitial ion homeostasis and acid-base balance. Tentatively, uncompromised brain ion homeostasis and acid-base balance may contribute to the relatively frequent brain function recovery and spontaneous survival rate in human patients with ATLF. Copyright © 2018. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Wei-Yu, E-mail: wychen624@cgmh.org.tw; Chang, Ya-Jen; Su, Chia-Hao
Interstitial fibrosis and loss of parenchymal tubular cells are the common outcomes of progressive renal diseases. Pro-inflammatory cytokines have been known contributing to the damage of tubular cells and fibrosis responses after renal injury. Interleukin (IL)-33 is a tissue-derived nucleus alarmin that drives inflammatory responses. The regulation and function of IL-33 in renal injury, however, is not well understood. To investigate the involvement of cytokines in the pathogenesis of renal injury and fibrosis, we performed the mouse renal injury model induced by unilateral urinary obstruction (UUO) and analyze the differentially upregulated genes between the obstructed and the contralateral unobstructed kidneysmore » using RNA sequencing (RNAseq). Our RNAseq data identified IL33 and its receptor ST2 were upregulated in the UUO kidney. Quantitative analysis confirmed that transcripts of IL33 and ST2 were upregulated in the obstructed kidneys. Immunofluorescent staining revealed that IL-33 was upregulated in Vimentin- and alpha-SMA-positive interstitial cells. By using genetically knockout mice, deletion of IL33 reduced UUO-induced renal fibrosis. Moreover, in combination with BrdU labeling technique, we observed that the numbers of proliferating tubular epithelial cells were increased in the UUO kidneys from IL33-or ST2-deficient mice compared to wild type mice. Collectively, our study demonstrated the upregulation of IL-33/ST2 signaling in the obstructed kidney may promote tubular cell injury and interstitial fibrosis. IL-33 may serve as a biomarker to detect renal injury and that IL-33/ST2 signaling may represent a novel target for treating renal diseases. -- Highlights: •Interleukin (IL)-33 was upregulated in obstructed kidneys. •Interstitial myofibroblasts expressed IL-33 after UUO-induced renal injury. •Deficiency of IL33 reduced interstitial fibrosis and promoted tubular cell proliferation.« less
Çakmakçı Karadoğan, Dilek; Balkarlı, Ayşe; Önal, Özgür; Altınışık, Göksel; Çobankara, Veli
2015-01-01
Nailfold capillaroscopy (NFC) is a non-invasive diagnostic test that is mostly used for early diagnosis of collagen tissue diseases (CTDs). We aimed to evaluate whether NFC findings could be a clue for discriminating idiopathic interstitial lung diseases (ILD) from CTD associated ILDs (CTD-ILD). Additionally it was aimed to determine whether NFC could be helpful in discriminating usual interstitial pneumonia (UIP) pattern from non-specific interstitial pneumonia (NSIP) pattern. We grouped patients into three main groups: 15 CTD-ILD, 18 idiopathic ILD, and 17 patients in the control group. The CTD-ILD group was split into two subgroups: 8 patients with Sjögren's syndrome (SJS)-associated ILD and 7 with rheumatoid arthritis (RA)-associated ILD. The idiopathic-ILD group consisted of 10 idiopathic NSIP and 8 IPF patients. The control group consisted of 10 SJS and 7 RA patients without lung disease. None of the patients were on acute exacerbation at the time of examination, and none had Reynaud's phenomenon. Mean capillary density was significantly reduced only in the CTD-ILD group as compared to the control group (p= 0.006). In subgroup analysis, it was determined that RA-ILD, IPF, and SJS-ILD subgroups had more severe capillaroscopic abnormalities. Mean capillary density in patients with the UIP pattern was reduced compared to patients with the NSIP pattern and those in the control group; p values were 0.008 and < 0.001, respectively. This study is to be the first describing and comparing the nailfold capillaroscopic findings of patients with NSIP and UIP patterns. NFC findings can be helpful in discriminating UIP patterns from NSIP patterns. But to show its role in differentiating idiopathic disease, more studies with more patients are needed.
Chrzanowski, Wojciech; Armitage, David Andrew; Knowles, Jonathan Campbell; Szade, Jacek; Korlacki, Wojciech; Marciniak, Jan
2008-07-01
The aim of this work is to examine the corrosion properties, chemical composition, and material-implant interaction after different periods of implantation of plates used to correct funnel chest. The implants are made of 316L stainless steel. Examinations are carried out on three implants: new (nonimplanted) and two implanted for 29 and 35 months. The corrosion study reveals that in the potential range that could occur in the physiological condition the new bar has the lowest current density and the highest corrosion potential. This indicates that the new plate has the highest corrosion resistance and the corrosion resistance could be reduced during implantation by the instruments used during the operation. XPS analysis reveals changes in the surface chemistry. The longer the implantation time the more carbon and oxygen are observed and only trace of elements such as Cr, Mo are detected indicating that surface is covered by an organic layer. On some parts of the implants whitish tissue is observed: the thickness of which increased with the time of implantation. This tissue was identified as an organic layer; mainly attached to the surface on the areas close to where the implant was bent to attain anatomical fit and thus where the implant has higher surface roughness. The study indicates that the chest plates are impaired by the implantation procedure and contact with biological environment. The organic layer on the surface shows that the implant did not stay passive but some reactions at the tissue-implant interface occurred. These reactions should be seen as positive, as it indicates that the implants were accepted by the tissues. Nevertheless, if the implants react, they may continue to release chromium, nickel, and other harmful ions long term as indicated by lower corrosion resistance of the implants following implantation.
Christensen, Ann-Eva; Lorenzen, Henning
2017-01-01
ABSTRACT Objectives The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. Material and Methods A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. Results The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. Conclusions A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level. PMID:28496962
Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning
2017-01-01
The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level.
Technical tips during implantation of selective upper airway stimulation.
Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits
2018-03-01
Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.
Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Araujo Lemos, Cleidiel Aparecido; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza
The aim of this study was to use three-dimensional finite element analysis to analyze the stress distribution transferred by single implant-supported prostheses placed in the anterior maxilla using different connections (external hexagon, internal hexagon, or Morse taper), inclinations of the load (0, 30, or 60 degrees), and surgical techniques for placement (monocortical/conventional, bicortical, or bicortical with nasal floor elevation). Nine models representing a bone block of this region were simulated by computer-aided design software (InVesalius, Rhinoceros, SolidWorks). Each model received one implant, which supported a cemented metalloceramic crown. Using FEMAP software, finite elements were discretized while simulating a 178-N load at 0, 30, and 60 degrees relative to the long axis of the implant. The problem was solved in NEi Nastran software, and postprocessing was performed in FEMAP. Von Mises stress and maximum principal stress maps were made. The von Mises stress analysis revealed that stress increased with increasing inclination of the load, from 0 to 30 to 60 degrees. Morse taper implants showed less stress concentration around the cervical and apical areas of the implant. The bicortical technique, associated or not with nasal floor elevation, contributed to decreasing the stress concentration in the apical area of the implant. Maximum principal stress analysis showed that the increase in inclination was proportional to the increase in stress on the bone tissue in the cervical area. Lower stress concentrations in the cortical bone were obtained with Morse taper implants and the bicortical technique compared with other connections and surgical techniques, respectively. Increasing the inclination of the applied force relative to the long axis of the implant tended to overload the peri-implant bone tissue and the internal structure of the implants. The Morse taper connection and bicortical techniques seemed to be more favorable than other connections or techniques, respectively, for restoring the anterior maxilla.
Lee, Sung-Ah; Lee, Chun-Teh; Fu, Martin M; Elmisalati, Waiel; Chuang, Sung-Kiang
2014-01-01
The aim of this study was to undertake a systematic review with meta-analysis on randomized controlled trials (RCTs) to compare the rates of survival, success, and complications of short implants to those of longer implants in the posterior regions. Electronic literature searches were conducted through the MEDLINE (PubMed) and EMBASE databases to locate all relevant articles published between January 1, 1990, and April 30, 2013. Eligible studies were selected based on inclusion criteria, and quality assessments were conducted. After data extraction, meta-analyses were performed. In total, 539 dental implants (265 short implants [length 5 to 8 mm] and 274 control implants [length > 8 mm]) from four RCTs were included. The fixed prostheses of multiple short and control implants were all splinted. The mean follow-up period was 2.1 years. The 1-year and 5-year cumulative survival rates (CSR) were 98.7% (95% confidence interval [CI], 97.8% to 99.5%) and 93.6% (95% CI, 89.8% to 97.5%), respectively, for the short implant group and 98.0% (95% CI, 96.9% to 99.1%) and 90.3% (95% CI, 85.2% to 95.4%), respectively, for the control implant group. The CSRs of the two groups did not demonstrate a statistically significant difference. There were also no statistically significant differences in success rates, failure rates, or complications between the two groups. Placement of short dental implants could be a predictable alternative to longer implants to reduce surgical complications and patient morbidity in situations where vertical augmentation procedures are needed. However, only four studies with potential risk of bias were selected in this meta-analysis. Within the limitations of this meta-analysis, these results should be confirmed with robust methodology and RCTs with longer follow-up duration.
Bailey, Nathanael G; South, Sarah T; Hummel, Marybeth; Wenger, Sharon L
2010-01-01
We report on a two-year-old female with a de novo proximal interstitial deletion of the short arm of chromosome 4 and a tetralogy of Fallot malformation. The patient had a karyotype of 46,XX,del(4)(p14p15.33) that was further characterized by array comparative genomic hybridization (aCGH). Phenotypic abnormalities for our patient are compared with those of previously reported patients with similar proximal 4p deletions as well as more distal deletions. The functions of genes that are deleted within this segment are reviewed.
Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe
2015-01-01
Purpose We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method. PMID:25793178
Mechanics of the tapered interference fit in dental implants.
Bozkaya, Dinçer; Müftü, Sinan
2003-11-01
In evaluation of the long-term success of a dental implant, the reliability and the stability of the implant-abutment interface plays a great role. Tapered interference fits provide a reliable connection method between the abutment and the implant. In this work, the mechanics of the tapered interference fits were analyzed using a closed-form formula and the finite element (FE) method. An analytical solution, which is used to predict the contact pressure in a straight interference, was modified to predict the contact pressure in the tapered implant-abutment interface. Elastic-plastic FE analysis was used to simulate the implant and abutment material behavior. The validity and the applicability of the analytical solution were investigated by comparisons with the FE model for a range of problem parameters. It was shown that the analytical solution could be used to determine the pull-out force and loosening-torque with 5-10% error. Detailed analysis of the stress distribution due to tapered interference fit, in a commercially available, abutment-implant system was carried out. This analysis shows that plastic deformation in the implant limits the increase in the pull-out force that would have been otherwise predicted by higher interference values.
Braicu, Elena Ioana; Van Gorp, Toon; Nassir, Mani; Richter, Rolf; Chekerov, Radoslav; Gasimli, Khayal; Timmerman, Dirk; Vergote, Ignace; Sehouli, Jalid
2014-01-01
Borderline tumors of the ovary (BOT) are a distinct entity of ovarian tumors, characterized by lack of stromal invasion. Recent studies postulated that the presence of invasive implants, incomplete staging, fertility sparing surgery and residual tumor after surgery are major prognostic factors for BOT. There are no biomarkers that can predict BOT or the presence of invasive implants. The aim of our study was to assess the value of CA125 and HE4 alone, or within ROMA score for detecting BOT, and for predicting the presence of invasive implants. Retrospective, monocentric study on 167 women diagnosed with BOT or benign ovarian masses. Serum HE4, CA125 levels and ROMA were assessed preoperatively. Due to low number of BOT with invasive implants, we performed an unmatched analysis (consecutive patients) and a matched analysis (according to age and histology) to compare BOT with invasive implants, BOT without invasive implants and benign disease. There were no significant differences in the HE4 and CA125 expressions in the three groups of patients (p = 0.984 and p = 0.141, respectively). The ROC analysis showed that CA125 alone is superior to ROMA and HE4 in discriminating patients with BOT with invasive implants from patients with benign diseases and BOT without invasive implants. A newly established score, ROMABOT, did not perform better than ROMA. The analysis of the matched groups revealed similar results as the analysis of all samples. Both HE4 and CA125 are not reliable biomarkers for the diagnosis of BOT or for predicting the presence of invasive implants.
Sadeghi, Rokhsareh; Miremadi, Asghar
2015-01-01
Objectives: Implant primary stability is one of the important factors in achieving implant success. The osteotome technique may improve primary stability in patients with poor bone quality. The aim of this study was to compare implant stability using two different techniques namely osteotome versus conventional drilling in the posterior maxilla. Materials and Methods: In this controlled randomized clinical trial, 54 dental implants were placed in 32 patients; 29 implants were placed in the osteotome group and 25 in the conventional drilling group. Implant stability was assessed at four time intervals namely at baseline, one, two and three months after implant placement using resonance frequency analysis (RFA). Results: Primary stability based on implant stability quotient (ISQ) units was 71.4±7 for the osteotome group and 67.4±10 for the control group. There was no statistically significant difference between the two groups in implant stability at any of the measurement times. In each group, changes in implant stability from baseline to one month and also from two months to three months post-operatively were not significant but from one month to two months after implant placement, implant stability showed a significant increase in both groups. Conclusion: The results of this study revealed that in both techniques, good implant stability was achieved and osteotome technique did not have any advantage compared to conventional drilling in this regard. PMID:27148375
Schouten, Corinne; Meijer, Gert J; van den Beucken, Jeroen J J P; Spauwen, Paul H M; Jansen, John A
2009-09-01
In the present study, the effects of implant design and surface properties on peri-implant bone response were evaluated with both conventional histomorphometry and micro-computed tomography (micro-CT), using two geometrically different dental implants (Screw type, St; Push-in, Pi) either or not surface-modified (non-coated, CaP-coated, or CaP-coated+TGF-beta1). After 12 weeks of implantation in a goat femoral condyle model, peri-implant bone response was evaluated in three different zones (inner: 0-500 microm; middle: 500-1000 microm; and outer: 1000-1500 microm) around the implant. Results indicated superiority of conventional histomorphometry over micro-CT, as the latter is hampered by deficits in the discrimination at the implant/tissue interface. Beyond this interface, both analysis techniques can be regarded as complementary. Histomorphometrical analysis showed an overall higher bone volume around St compared to Pi implants, but no effects of surface modification were observed. St implants showed lowest bone volumes in the outer zone, whereas inner zones were lowest for Pi implants. These results implicate that for Pi implants bone formation started from two different directions (contact- and distance osteogenesis). For St implants it was concluded that undersized implantation technique and loosening of bone fragments compress the zones for contact and distant osteogenesis, thereby improving bone volume at the interface significantly.
Wohlfahrt, Johan Caspar; Aass, Anne Merete; Ronold, Hans Jacob; Lyngstadaas, Stale Petter
2011-01-01
Treatment of peri-implant osseous defects represents a significant challenge for clinicians, and the need to evolve within predictable surgical procedures is important. This case report describes the surgical treatment and grafting with porous titanium granules (PTG) of one patient with a peri-implant osseous defect. The suggested thrombogenic properties of titanium are intriguing from the perspective of osseous reconstructive surgery. In an ongoing randomized clinical trial using PTG for treatment of peri-implant osseous defects, one patient with one test implant was excluded and scheduled for implant removal. The surgical therapy included open flap debridement with surface decontamination with 24% EDTA gel, grafting with PTG, and resubmersion of the implant. After 12 months of healing, the implant with surrounding tissues was excised en bloc and micro CT and histological analyses were performed. Analyses showed PTG in close contact with new bone and with bone growing both into the porosities of the graft material and onto the adjacent implant surface. Element analysis demonstrated calcium and phosphorus in the new tissue embedding the PTG and the implant. Int J Oral Maxillofac Implants 2011;26:e9-e14.
Antetomaso, Jordan; Kumar, Satish
2018-03-01
Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: a systematic review and meta-analysis. Mello CC, Lemos CAA, Verri FR, Dos Santos DM, Goiato MC, Pellizzer EP. Int J Oral Maxillofac Surg 2017; 46(9):1162-77. None TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data. Copyright © 2017 Elsevier Inc. All rights reserved.
Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; de Mattos, Maria da Gloria Chiarello
2012-11-01
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.
Finite element analysis of a novel implant distribution to support maxillary overdentures.
Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V
2013-01-01
To evaluate the biomechanics of a novel implant placement distribution and compare it with that of conventional maxillary overdenture support using three-dimensional finite element analysis (FEA). The application of zirconia implants in the context of this novel design was also evaluated. Detailed FEA models were created to analyze the loading responses of two different distributions of implants to support maxillary overdentures. The two implant distributions were as follows: the conventional design (D1) included four unsplinted implants in the premolar regions, whereas the novel design (D2) included one midpalatal implant, bilateral canine/premolar implants, and one anterior off-center crestal implant. Anatomical models were created with computed tomographic data and static loads were applied axially and obliquely. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated, including any denture displacement. Comparable stress and strain values were seen in the peri-implant bone for both designs. A significant decrease in the first principal stresses of D2 implants was observed with oblique loads. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. D2 displayed lower maximum displacement values than D1. Maximum tensile stresses in the zirconia implants for either design were well below their fracture strength. A novel four-implant distribution involving midpalatal and crestal implants may be an alternative to the conventional design used for maxillary overdentures. This is particularly relevant when anatomical considerations prevent the placement of four anterior crestal implants. Zirconia implants may also be a valid option for a selected group of patients or for those requesting metal-free restorations. Prospective clinical studies are required to confirm these in vitro results.
Lung volumes and emphysema in smokers with interstitial lung abnormalities.
Washko, George R; Hunninghake, Gary M; Fernandez, Isis E; Nishino, Mizuki; Okajima, Yuka; Yamashiro, Tsuneo; Ross, James C; Estépar, Raúl San José; Lynch, David A; Brehm, John M; Andriole, Katherine P; Diaz, Alejandro A; Khorasani, Ramin; D'Aco, Katherine; Sciurba, Frank C; Silverman, Edwin K; Hatabu, Hiroto; Rosas, Ivan O
2011-03-10
Cigarette smoking is associated with emphysema and radiographic interstitial lung abnormalities. The degree to which interstitial lung abnormalities are associated with reduced total lung capacity and the extent of emphysema is not known. We looked for interstitial lung abnormalities in 2416 (96%) of 2508 high-resolution computed tomographic (HRCT) scans of the lung obtained from a cohort of smokers. We used linear and logistic regression to evaluate the associations between interstitial lung abnormalities and HRCT measurements of total lung capacity and emphysema. Interstitial lung abnormalities were present in 194 (8%) of the 2416 HRCT scans evaluated. In statistical models adjusting for relevant covariates, interstitial lung abnormalities were associated with reduced total lung capacity (-0.444 liters; 95% confidence interval [CI], -0.596 to -0.292; P<0.001) and a lower percentage of emphysema defined by lung-attenuation thresholds of -950 Hounsfield units (-3%; 95% CI, -4 to -2; P<0.001) and -910 Hounsfield units (-10%; 95% CI, -12 to -8; P<0.001). As compared with participants without interstitial lung abnormalities, those with abnormalities were more likely to have a restrictive lung deficit (total lung capacity <80% of the predicted value; odds ratio, 2.3; 95% CI, 1.4 to 3.7; P<0.001) and were less likely to meet the diagnostic criteria for chronic obstructive pulmonary disease (COPD) (odds ratio, 0.53; 95% CI, 0.37 to 0.76; P<0.001). The effect of interstitial lung abnormalities on total lung capacity and emphysema was dependent on COPD status (P<0.02 for the interactions). Interstitial lung abnormalities were positively associated with both greater exposure to tobacco smoke and current smoking. In smokers, interstitial lung abnormalities--which were present on about 1 of every 12 HRCT scans--were associated with reduced total lung capacity and a lesser amount of emphysema. (Funded by the National Institutes of Health and the Parker B. Francis Foundation; ClinicalTrials.gov number, NCT00608764.).
Brekke, Hege Kristin; Hammersborg, Stig Morten; Lundemoen, Steinar; Mongstad, Arve; Kvalheim, Venny Lise; Haugen, Oddbjørn; Husby, Paul
2013-10-01
A highly positive intraoperative fluid balance should be prevented as it negatively impacts patient outcome. Analysis of volume-kinetics has identified an increase in interstitial fluid volume after crystalloid fluid loading during isoflurane anesthesia. Isoflurane has also been associated with postoperative hypoxemia and may be associated with an increase in alveolar epithelial permeability, edema formation, and hindered oxygen exchange. In this article, the authors compare fluid extravasation rates before and during cardiopulmonary bypass (CPB) with isoflurane- versus propofol-based anesthesia. Fourteen pigs underwent 2 h of tepid CPB with propofol (P-group; n = 7) or isoflurane anesthesia (I-group; n = 7). Fluid requirements, plasma volume, colloid osmotic pressures in plasma and interstitial fluid, hematocrit levels, and total tissue water content were recorded, and fluid extravasation rates calculated. Fluid extravasation rates increased in the I-group from the pre-CPB level of 0.27 (0.13) to 0.92 (0.36) ml·kg·min, but remained essentially unchanged in the P-group with significant between-group differences during CPB (pb = 0.002). The results are supported by corresponding changes in interstitial colloid osmotic pressure and total tissue water content. During CPB, isoflurane, in contrast to propofol, significantly contributes to a general increase in fluid shifts from the intravascular to the interstitial space with edema formation and a possible negative impact on postoperative organ function.
Vocabulary Knowledge of Children With Cochlear Implants: A Meta-Analysis
2016-01-01
This article employs meta-analysis procedures to evaluate whether children with cochlear implants demonstrate lower spoken-language vocabulary knowledge than peers with normal hearing. Of the 754 articles screened and 52 articles coded, 12 articles met predetermined inclusion criteria (with an additional 5 included for one analysis). Effect sizes were calculated for relevant studies and forest plots were used to compare differences between groups of children with normal hearing and children with cochlear implants. Weighted effect size averages for expressive vocabulary measures (g = −11.99; p < .001) and for receptive vocabulary measures (g = −20.33; p < .001) indicated that children with cochlear implants demonstrate lower vocabulary knowledge than children with normal hearing. Additional analyses confirmed the value of comparing vocabulary knowledge of children with hearing loss to a tightly matched (e.g., socioeconomic status-matched) sample. Age of implantation, duration of implantation, and chronological age at testing were not significantly related to magnitude of weighted effect size. Findings from this analysis represent a first step toward resolving discrepancies in the vocabulary knowledge literature. PMID:26712811
A macro- and nanostructure evaluation of a novel dental implant.
Tetè, Stefano; Mastrangelo, Filiberto; Traini, Tonino; Vinci, Raffaele; Sammartino, Gilberto; Marenzi, Gaetano; Gherlone, Enrico
2008-09-01
Success in implant dentistry also comes from the implant macrodesign and nanostructure of its surface. Titanium implant surface treatments have been shown to enhance osseointegration, maximize bone healing, and bone-to-implant contact for predictable clinical results. The aim of the study, was to evaluate the geometric macrodesign and the surface nanostructure of a novel dental implant full contact covering (FCC) obtained by electrochemical procedures. FCC implants were analyzed by scanning electronic microscope, profilometer, and x-ray photoelectron spectroscopy and compared with commercial sandblasted and sandblasted, large-grit acid-etched dental implants. Sample analysis allowed to distinguish the different implant macrodesigns, the step and the profile of the coils that cover the fixture, and the surface characteristics. FCC implant showed novel macro-characteristic of crestal module, coils, and apical zone compared with sandblasted and sandblasted and acid-etched dental implants. Moreover, the FCC nanostructure surface showed roughness values statistically higher than the 2 other surfaces, with a more homogeneity in a peaks and valleys arrangement. Finally, the x-ray photoelectron spectroscopy analysis detected differences between the examined surfaces, with the presence of several contaminants according to the different treatment procedures. Research on new macrostructures and nano morphology should result in a better qualitative and quantitative osseointegration response, with a predictability of the clinical results and long-term success of the implants.
Bacterial plaque colonization around dental implant surfaces.
Covani, Ugo; Marconcini, Simone; Crespi, Roberto; Barone, Antonio
2006-09-01
To examine the distribution of bacteria into the internal and external surfaces of failed implants using histologic analysis. There were 10 failed pure titanium and 5 failed hydroxyapatite-coated titanium implants consecutively removed various years after their placement. Criteria for fixture removal were peri-implant radiolucency and clinical mobility. The mobile fixtures were retrieved with the patients under local anesthesia. Fixtures were removed maintaining the abutments with the aim to observe the bacterial infiltration at the level of abutment/implant interface and on the implant surface. A thin radiolucent space was always present around all the failed implants. The abutments screws were tightly secured in all clinical cases. The bacterial cells were composed of cocci and filaments, which were adherent to the implant surface with an orientation perpendicular to the long axis of the implant. All the specimens included in this study showed bacteria at the level of implant/abutment interface. Histologic analysis at the level of abutment/implant interface in 2-stage implants identified heavy bacterial colonization. These findings appear to support those studies showing bacteria penetration at the level of the micro-gap, which can legitimate the hypothesis that the micro-gap at the bone level could present a risk for bone loss caused by bacterial colonization.
Chang, Moontaek; Wennström, Jan L
2012-06-01
To evaluate longitudinal changes in tooth/implant relationship and bone topography at single implants with a microthreaded, conical marginal portion (Astra Tech ST® implants, Astra Tech AB, Mölndal, Sweden). Thirty-one subjects with single implant-supported restorations in the esthetic zone were included. Radiographs obtained at crown installation and 1, 5, and 8 years of follow-up were analyzed with regard to changes in (1) bone level at the implant and adjacent teeth and (2) vertical position of adjacent teeth relative to the single implant. The mean marginal bone loss amounted to 0.1 mm at both implants and adjacent teeth during the 8 years of follow-up. Regression analysis failed to identify significant explanatory factors for observed variance in bone level change at the adjacent tooth surfaces. Vertical change in position of the teeth relative to the implants was more frequent and significantly greater in incisor compared with premolar tooth region but not associated with gender or age. The marginal bone level at teeth adjacent to single implants with a microthreaded conical marginal part was not influenced by horizontal and vertical tooth-implant distances. Continuous eruption of adjacent teeth may result in infraocclusal positioning of a single-implant restoration. © 2010 Wiley Periodicals, Inc.
Tran, Duong T; Gay, Isabel C; Diaz-Rodriguez, Janice; Parthasarathy, Kavitha; Weltman, Robin; Friedman, Lawrence
2016-01-01
To compare dental implant survival rates when placed in native bone and grafted sites. Additionally, risk factors associated with dental implant loss were identified. This study was based on the hypothesis that bone grafting has no effect on implant survival rates. A retrospective chart review was conducted for patients receiving dental implants at the University of Texas, School of Dentistry from 1985 to 2012. Exclusion criteria included patients with genetic diseases, radiation and chemotherapy, or an age less than 18 years. To avoid misclassification bias, implants were excluded if bone grafts were only done at the same time of placement. Data on age, sex, tobacco use, diabetes, osteoporosis, anatomical location of the implant, implant length and width, bone graft, and professional maintenance were collected for analysis. A total of 1,222 patients with 2,729 implants were included. The cumulative survival rates at 5 and 10 years were 92% and 87% for implants placed in native bone and 90% and 79% for implants placed in grafted bone, respectively. The results from multivariate analysis (Cox regression) indicated no significant difference in survival between the two groups; having maintenance therapy after implant placement reduced the failure rate by 80% (P < .001), and using tobacco increased the failure rate by 2.6-fold (P = .001). There was no difference in the dental implant survival rate when implants were placed in native bone or bone-grafted sites. Smoking and lack of professional maintenance were significantly related to increased implant loss.
Mosavar, Alireza; Nili, Monireh; Hashemi, Sayed Raouf; Kadkhodaei, Mahmoud
2017-06-01
Depending on esthetic, anatomical, and functional aspects, in implant-prosthetic restoration of a completely edentulous jaw, the selection of implant type is highly important; however, bone- and tissue-level implants and their stress distribution in bone have not yet been comparatively investigated. Hence, finite element analysis was used to study the influence of cantilever length in a fixed prosthesis on stress distribution in peri-implant bone around these two types of oral implants. A 3D edentulous mandible was modeled. In simulations, a framework with four posterior cantilever lengths and two types of implants, bone-level and tissue-level, was considered. A compressive load was applied to the distal regions of the cantilevers, and the von-Mises stress of peri-implant bone was investigated. The independent t-test and the Pearson correlation coefficient analyzed the results (α = 0.05). Stresses in the cortical bone around the bone-level implants were greater than those in the tissue-level implants with the same cantilever length. In addition, by extending the cantilever length, the stress values in peri-implant bone increased. Therefore, when the cantilever was at its maximum length, the maximum stress was in cortical bone and around the bone-level distal implants. The results of the present study indicate that treatment with tissue-level implants is potentially more advantageous than with bone-level implants for implant-supported fixed prostheses. © 2015 by the American College of Prosthodontists.
Djoudi, Farid
2013-01-01
Two separate themes are presented in this paper. The first theme is to present a graphical modeling approach of human anatomical structures namely, the femur and the tibia. The second theme involves making a finite element analysis of stresses, displacements and deformations in prosthetic implants (the femoral implant and the polyethylene insert). The graphical modeling approach comes in two parts. The first is the segmentation of MRI scanned images, retrieved in DICOM format for edge detection. In the second part, 3D-CAD models are generated from the results of the segmentation stage. The finite element analysis is done by first extracting the prosthetic implants from the reconstructed 3D-CAD model, then do a finite element analysis of these implants under objectively determined conditions such as; forces, allowed displacements, the materials composing implant, and the coefficient of friction. The objective of this work is to implement an interface for exchanging data between 2D MRI images obtained from a medical diagnosis of a patient and the 3D-CAD model used in various applications, such as; the extraction of the implants, stress analysis at the knee joint and can serve as an aid to surgery, also predict the behavior of the prosthetic implants vis-a-vis the forces acting on the knee joints.
Interstitial lung disease is the name for a large group of diseases that inflame or scar the lungs. The inflammation and ... is responsible for some types of interstitial lung diseases. Specific types include Black lung disease among coal ...
Wijetunge, S.; Ratnatunga, N. V. I.; Abeysekera, T. D. J.; Wazil, A. W. M.; Selvarajah, M.
2015-01-01
Chronic kidney disease of unknown etiology (CKDU) is endemic among the rural farming communities in several localities in and around the North Central region of Sri Lanka. This is an interstitial type renal disease and typically has an insidious onset and slow progression. This study was conducted to identify the pathological features in the different clinical stages of CKDU. This is a retrospective study of 251 renal biopsies identified to have a primary interstitial disease from regions endemic for CKDU. Pathological features were assessed and graded in relation to the clinical stage. The mean age of those affected by endemic CKDU was 37.3 ± 12.5 years and the male to female ratio was 3.3:1. The predominant feature of stage I disease was mild and moderate interstitial fibrosis; most did not have interstitial inflammation. The typical stage II disease had moderate interstitial fibrosis with or without mild interstitial inflammation. Stage III disease had moderate and severe interstitial fibrosis, moderate interstitial inflammation, tubular atrophy and some glomerulosclerosis. Stage IV disease typically had severe interstitial fibrosis and inflammation, tubular atrophy and glomerulosclerosis. The mean age of patients with stage I disease (27 ± 10.8 years) was significantly lower than those of the other stages. About 79.2%, 55%, 49.1% and 50% in stage I, II, III and IV disease respectively were asymptomatic at the time of biopsy. PMID:26628792
Deficiency of interstitial cells of Cajal in the small intestine of patients with Crohn's disease.
Porcher, Christophe; Baldo, Marjolaine; Henry, Monique; Orsoni, Pierre; Julé, Yvon; Ward, Sean M
2002-01-01
Interstitial cells of Cajal are critical for the generation of electrical slow waves that regulate the phasic contractile activity of the tunica muscularis of the GI tract. Under certain pathophysiological conditions loss of interstitial cells of Cajal may play a role in the generation of certain motility disorders. The aim of the present study was to determine if there is an abnormality in the density or distribution of interstitial cells of Cajal from patients with Crohn's disease. Small intestines from control subjects and patients with Crohn's disease were examined using immunohistochemistry and antibodies against the Kit receptor, which is expressed in interstitial cells of Cajal within the tunica muscularis of the GI tract. The density and distribution of interstitial cells of Cajal were assessed in the longitudinal and circular muscle layers and in the myenteric and deep muscular plexus regions of Crohn's and control tissues. Tissues from Crohn's disease patients showed an almost complete abolition of interstitial cells of Cajal within the longitudinal and circular muscle layers and a significant reduction in numbers at the level of the myenteric and deep muscular plexuses. In tissues from Crohn's disease patients, the density of interstitial cells of Cajal was reduced throughout the tunica muscularis in comparison to control small intestines. The disturbance of intestinal motility that occurs in patients with Crohn's disease may be a consequence of the loss of or defects in specific populations of interstitial cells of Cajal within the tunica muscularis.
Hwang, Jeong-Hwa; Misumi, Shigeki; Sahin, Hakan; Brown, Kevin K; Newell, John D; Lynch, David A
2009-01-01
To compare the computed tomographic (CT) features of idiopathic fibrosing interstitial pneumonia with those of pulmonary fibrosis related to collagen vascular disease (CVD). We reviewed the CT scans of 177 patients with diffuse interstitial pulmonary fibrosis, of which 97 had idiopathic fibrosing interstitial pneumonia and 80 had CVD. The CT images were systematically scored for the presence and extent of pulmonary and extrapulmonary abnormalities. Computed tomographic diagnosis of usual interstitial pneumonia (UIP) or nonspecific interstitial pneumonia (NSIP) was assigned. A CT pattern of UIP was identified in 59 (60.8%) of patients with idiopathic fibrosing interstitial pneumonia compared with 15 (18.7%) of those patients with CVD; conversely, the CT diagnosis of NSIP was made in 51 (64%) of patients with CVD compared with 36 (37%) of patients with idiopathic disease (P < 0.01). In 113 patients who had lung biopsy, the CT diagnoses of UIP and NSIP were concordant with the histologic diagnoses in 36 of 50 patients and 34 of 41 patients, respectively. Pleural effusions, esophageal dilation, and pericardial abnormalities were more frequent in patients with CVD than in patients with idiopathic fibrosing interstitial pneumonia. Compared with patients with CVD, those patients with an idiopathic fibrosing interstitial pneumonia showed a higher prevalence of a UIP pattern and lower prevalence of an NSIP pattern as determined by CT. Identification of coexisting extrapulmonary abnormalities on CT can support a diagnosis of CVD.
NASA Astrophysics Data System (ADS)
Thompson, M.; Drummond, D.; Sullivan, J.; Elliman, R.; Kluth, P.; Kirby, N.; Riley, D.; Corr, C. S.
2018-06-01
To determine the effect of pre-existing defects on helium-vacancy cluster nucleation and growth, tungsten samples were self-implanted with 1 MeV tungsten ions at varying fluences to induce radiation damage, then subsequently exposed to helium plasma in the MAGPIE linear plasma device. Positron annihilation lifetime spectroscopy was performed both immediately after self-implantation, and again after plasma exposure. After self-implantation vacancies clusters were not observed near the sample surface (<30 nm). At greater depths (30–150 nm) vacancy clusters formed, and were found to increase in size with increasing W-ion fluence. After helium plasma exposure in the MAGPIE linear plasma device at ~300 K with a fluence of 1023 He-m‑2, deep (30–150 nm) vacancy clusters showed similar positron lifetimes, while shallow (<30 nm) clusters were not observed. The intensity of positron lifetime signals fell for most samples after plasma exposure, indicating that defects were filling with helium. The absence of shallow clusters indicates that helium requires pre-existing defects in order to drive vacancy cluster growth at 300 K. Further samples that had not been pre-damaged with W-ions were also exposed to helium plasma in MAGPIE across fluences from 1 × 1022 to 1.2 × 1024 He-m‑2. Samples exposed to fluences up to 1 × 1023 He-m‑2 showed no signs of damage. Fluences of 5 × 1023 He-m‑2 and higher showed significant helium-cluster formation within the first 30 nm, with positron lifetimes in the vicinity 0.5–0.6 ns. The sample temperature was significantly higher for these higher fluence exposures (~400 K) due to plasma heating. This higher temperature likely enhanced bubble formation by significantly increasing the rate interstitial helium clusters generate vacancies, which is we suspect is the rate-limiting step for helium-vacancy cluster/bubble nucleation in the absence of pre-existing defects.
Liu, Jingyin; Pan, Shaoxia; Dong, Jing; Mo, Zhongjun; Fan, Yubo; Feng, Hailan
2013-03-01
The aim of this study was to evaluate strain distribution in peri-implant bone, stress in the abutments and denture stability of mandibular overdentures anchored by different numbers of implants under different loading conditions, through three-dimensional finite element analysis (3D FEA). Four 3D finite element models of mandibular overdentures were established, using between one and four Straumann implants with Locator attachments. Three types of load were applied to the overdenture in each model: 100N vertical and inclined loads on the left first molar and a 100N vertical load on the lower incisors. The biomechanical behaviours of peri-implant bone, implants, abutments and overdentures were recorded. Under vertical load on the lower incisors, the single-implant overdenture rotated over the implant from side to side, and no obvious increase of strain was found in peri-implant bone. Under the same loading conditions, the two-implant-retained overdenture showed more apparent rotation around the fulcrum line passing through the two implants, and the maximum equivalent stress in the abutments was higher than in the other models. In the three-implant-supported overdenture, no strain concentration was found in cortical bone around the middle implant under three loading conditions. Single-implant-retained mandibular overdentures do not show damaging strain concentration in the bone around the only implant and may be a cost-effective treatment option for edentulous patients. A third implant can be placed between the original two when patients rehabilitated by two-implant overdentures report constant and obvious denture rotation around the fulcrum line. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mueller, Cornelia Katharina; Thorwarth, Michael; Schultze-Mosgau, Stefan
2011-01-01
The structure of peri-implant soft tissue that is regenerated after flapless and flap surgery has been shown to differ. However, its underlying mechanisms are relatively unknown. The present study sought to identify differences in the inflammatory cell infiltration and expression of gene transcripts during transmucosal healing between the two approaches with two different implant designs. All mandibular premolars were removed from 12 minipigs. One month later, four implants (two NobelReplace Tapered Groovy and two NobelPerfect Groovy, Nobel Biocare) were placed in each quadrant. One quadrant was randomized to flapless insertion, while the other was chosen for flap surgery in each animal. Following 1, 2, 4, and 12 weeks of transmucosal implant healing, biopsy specimens were retrieved from the peri-implant soft tissue according to a standardized procedure to avoid crossover effects. Samples were subjected to a leukocyte count and a gene expression analysis. When the flapless placement technique was used, leukocyte influx in the peri-implant soft tissue was significantly smaller compared to open surgery for both implant designs. Gene expression analysis revealed significant overexpression of molecules associated with detoxification and reepithelialization in the flapless group. In contrast, myofibroblast-associated gene transcripts were significantly enriched in the flap surgery group. The present data indicate perpetuation of inflammatory reactions as well as increased fibrotic scar tissue deposition in the peri-implant area following implant placement by the flap approach. Flapless implant insertion results in less inflammation and early reepithelialization, providing the potential for the formation of a fully functioning as well as esthetically preferable peri-implant soft tissue collar.
Chang, Yun-Young; Kim, Su-Hwan; Park, Keun-Oh; Yun, Jeong-Ho
2017-12-01
The objective of this study was to investigate the effect of microthreads on the coronal bone healing of narrow-diameter implants with reverse-tapered design. A total of 52 implants were classified into two groups according to presence or absence of coronal microthreads, the reverse-tapered narrow-diameter implant (RTN) group, and the reverse-tapered narrow-diameter implant with microthreads (RTNM) group. The implants were installed in split-mouth design in the edentulous mandible of six dogs. Three animals were sacrificed at 4 weeks and three at 8 weeks. Resonance frequency analysis, bone measurement using microcomputed tomography (micro-CT), removal torque test, and histometric analysis were performed. No significant differences in implant stability quotient value were observed between the groups at baseline, 4 weeks, or 8 weeks. Bone measurement using micro-CT showed that bone-implant contact volume (BICV) and bone-implant contact volume ratio (BICVR) in the coronal part of RTNM were statistically higher than those in RTN at 4 and 8 weeks. Histometric analysis showed statistically higher bone-implant contact length (BICL) in the coronal part of RTNM than in RTN at 4 weeks; however, bone-implant contact ratio (BICR) was not significantly different between the groups. At 8 weeks, the BICL and BICR did not differ significantly between the groups. Removal torque test showed no significant differences between the groups at 4 and 8 weeks. The microthreads might facilitate more coronal bone-implant contact due to increased surface areas at an early healing phase; however, they did not significantly affect coronal bone healing at 8 weeks. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wang, Qing-qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
Objective This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. Method A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Result Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Conclusion Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research. PMID:29049323
Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.
Induced Autologous Stem Cell Transplantation for Treatment of Rabbit Renal Interstitial Fibrosis
Ruan, Guang-Ping; Xu, Fan; Li, Zi-An; Zhu, Guang-Xu; Pang, Rong-Qing; Wang, Jin-Xiang; Cai, Xue-Min; He, Jie; Yao, Xiang; Ruan, Guang-Hong; Xu, Xin-Ming; Pan, Xing-Hua
2013-01-01
Introduction Renal interstitial fibrosis (RIF) is a significant cause of end-stage renal failure. The goal of this study was to characterize the distribution of transplanted induced autologous stem cells in a rabbit model of renal interstitial fibrosis and evaluate its therapeutic efficacy for treatment of renal interstitial fibrosis. Methods A rabbit model of renal interstitial fibrosis was established. Autologous fibroblasts were cultured, induced and labeled with green fluorescent protein (GFP). These labeled stem cells were transplanted into the renal artery of model animals at 8 weeks. Results Eight weeks following transplantation of induced autologous stem cells, significant reductions (P < 0.05) were observed in serum creatinine (SCr) (14.8 ± 1.9 mmol/L to 10.1 ± 2.1 mmol/L) and blood urea nitrogen (BUN) (119 ± 22 µmol/L to 97 ± 13 µmol/L), indicating improvement in renal function. Conclusions We successfully established a rabbit model of renal interstitial fibrosis and demonstrated that transplantation of induced autologous stem cells can repair kidney damage within 8 weeks. The repair occurred by both inhibition of further development of renal interstitial fibrosis and partial reversal of pre-existing renal interstitial fibrosis. These beneficial effects lead to the development of normal tissue structure and improved renal function. PMID:24367598
NASA Technical Reports Server (NTRS)
Goesele, U.; Ast, D. G.
1983-01-01
Some background information on intrinsic point defects is provided and on carbon and oxygen in silicon in so far as it may be relevant for the efficiency of solar cells fabricated from EFG ribbon material. The co-precipitation of carbon and oxygen and especially of carbon and silicon self interstitials are discussed. A simple model for the electrical activity of carbon-self-interstitial agglomerates is presented. The self-interstitial content of these agglomerates is assumed to determine their electrical activity and that both compressive stresses (high self-interstitial content) and tensile stresses (low self-interstitial content) give rise to electrical activity of the agglomerates. The self-interstitial content of these carbon-related agglomerates may be reduced by an appropriate high temperature treatment and enhanced by a supersaturation of self-interstitials generated during formation of the p-n junction of solar cells. Oxygen present in supersaturation in carbon-rich silicon may be induced to form SiO, precipitates by self-interstitials generated during phosphorus diffusion. It is proposed that the SiO2-Si interface of the precipates gives rise to a continuum of donor stables and that these interface states are responsible for at least part of the light inhancement effects observed in oxygen containing EFG silicon after phosphorus diffusion.
Vrana, Nihal E.; Dupret-Bories, Agnes; Chaubaroux, Christophe; Rieger, Elisabeth; Debry, Christian; Vautier, Dominique; Metz-Boutigue, Marie-Helene; Lavalle, Philippe
2013-01-01
Metallic implants, especially titanium implants, are widely used in clinical applications. Tissue in-growth and integration to these implants in the tissues are important parameters for successful clinical outcomes. In order to improve tissue integration, porous metallic implants have being developed. Open porosity of metallic foams is very advantageous, since the pore areas can be functionalized without compromising the mechanical properties of the whole structure. Here we describe such modifications using porous titanium implants based on titanium microbeads. By using inherent physical properties such as hydrophobicity of titanium, it is possible to obtain hydrophobic pore gradients within microbead based metallic implants and at the same time to have a basement membrane mimic based on hydrophilic, natural polymers. 3D pore gradients are formed by synthetic polymers such as Poly-L-lactic acid (PLLA) by freeze-extraction method. 2D nanofibrillar surfaces are formed by using collagen/alginate followed by a crosslinking step with a natural crosslinker (genipin). This nanofibrillar film was built up by layer by layer (LbL) deposition method of the two oppositely charged molecules, collagen and alginate. Finally, an implant where different areas can accommodate different cell types, as this is necessary for many multicellular tissues, can be obtained. By, this way cellular movement in different directions by different cell types can be controlled. Such a system is described for the specific case of trachea regeneration, but it can be modified for other target organs. Analysis of cell migration and the possible methods for creating different pore gradients are elaborated. The next step in the analysis of such implants is their characterization after implantation. However, histological analysis of metallic implants is a long and cumbersome process, thus for monitoring host reaction to metallic implants in vivo an alternative method based on monitoring CGA and different blood proteins is also described. These methods can be used for developing in vitro custom-made migration and colonization tests and also be used for analysis of functionalized metallic implants in vivo without histology. PMID:23851618
Vrana, Nihal E; Dupret-Bories, Agnes; Chaubaroux, Christophe; Rieger, Elisabeth; Debry, Christian; Vautier, Dominique; Metz-Boutigue, Marie-Helene; Lavalle, Philippe
2013-07-01
Metallic implants, especially titanium implants, are widely used in clinical applications. Tissue in-growth and integration to these implants in the tissues are important parameters for successful clinical outcomes. In order to improve tissue integration, porous metallic implants have being developed. Open porosity of metallic foams is very advantageous, since the pore areas can be functionalized without compromising the mechanical properties of the whole structure. Here we describe such modifications using porous titanium implants based on titanium microbeads. By using inherent physical properties such as hydrophobicity of titanium, it is possible to obtain hydrophobic pore gradients within microbead based metallic implants and at the same time to have a basement membrane mimic based on hydrophilic, natural polymers. 3D pore gradients are formed by synthetic polymers such as Poly-L-lactic acid (PLLA) by freeze-extraction method. 2D nanofibrillar surfaces are formed by using collagen/alginate followed by a crosslinking step with a natural crosslinker (genipin). This nanofibrillar film was built up by layer by layer (LbL) deposition method of the two oppositely charged molecules, collagen and alginate. Finally, an implant where different areas can accommodate different cell types, as this is necessary for many multicellular tissues, can be obtained. By, this way cellular movement in different directions by different cell types can be controlled. Such a system is described for the specific case of trachea regeneration, but it can be modified for other target organs. Analysis of cell migration and the possible methods for creating different pore gradients are elaborated. The next step in the analysis of such implants is their characterization after implantation. However, histological analysis of metallic implants is a long and cumbersome process, thus for monitoring host reaction to metallic implants in vivo an alternative method based on monitoring CGA and different blood proteins is also described. These methods can be used for developing in vitro custom-made migration and colonization tests and also be used for analysis of functionalized metallic implants in vivo without histology.
The analysis of cost-effectiveness of implant and conventional fixed dental prosthesis.
Chun, June Sang; Har, Alix; Lim, Hyun-Pil; Lim, Hoi-Jeong
2016-02-01
This study conducted an analysis of cost-effectiveness of the implant and conventional fixed dental prosthesis (CFDP) from a single treatment perspective. The Markov model for cost-effectiveness analysis of the implant and CFDP was carried out over maximum 50 years. The probabilistic sensitivity analysis was performed by the 10,000 Monte-Carlo simulations, and cost-effectiveness acceptability curves (CEAC) were also presented. The results from meta-analysis studies were used to determine the survival rates and complication rates of the implant and CFDP. Data regarding the cost of each treatment method were collected from University Dental Hospital and Statistics Korea for 2013. Using the results of the patient satisfaction survey study, quality-adjusted prosthesis year (QAPY) of the implant and CFDP strategy was evaluated with annual discount rate. When only the direct cost was considered, implants were more cost-effective when the willingness to pay (WTP) was more than 10,000 won at 10(th) year after the treatment, and more cost-effective regardless of the WTP from 20(th) year after the prosthodontic treatment. When the indirect cost was added to the direct cost, implants were more cost-effective only when the WTP was more than 75,000 won at the 10(th) year after the prosthodontic treatment, more than 35,000 won at the 20(th) year after prosthodontic treatment. The CFDP was more cost-effective unless the WTP was more than 75,000 won at the 10(th) year after prosthodontic treatment. But the cost-effectivenss tendency changed from CFDP to implant as time passed.
Vlahovic, Zoran; Markovic, Aleksa; Golubovic, Mileta; Scepanovic, Miodrag; Kalanovic, Milena; Djinic, Ana
2015-11-01
The aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis. The experiment was conducted on five domestic pigs. Nine weeks after tooth extraction, implants were installed. Each animal received six implants in mandible. According to split-mouth design, randomly one side was used for flapless technique using mini-incision, while on the other side, flap was raised. After 7, 14, 21, 28, and 90 days, the experimental animals were sacrificed. Samples for histopathological analyzes were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The degree of inflammatory response in the peri-implant soft tissue was estimated through ordinal scores from 0 to 3. In the flap group Score 3 indicating high degree of inflammation was present from day 7 to day 21, in contrast to flapless group where Score 3 was not recorded during the entire follow-up. Three months after implantation, there were no signs of inflammation neither around flap nor around flapless implants. Flapless surgical implantation technique using mini-incision decreases peri-implant soft tissue inflammatory reaction compared with flap surgery. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Yagishita, Mizuki; Kondo, Yuya; Terasaki, Toshihiko; Terasaki, Mayu; Shimizu, Masaru; Honda, Fumika; Oyama, Ayako; Takahashi, Hiroyuki; Yokosawa, Masahiro; Asashima, Hiromitsu; Hagiwara, Shinya; Tsuboi, Hiroto; Matsumoto, Isao; Sumida, Takayuki
2018-02-28
Patients with clinically amyopathic dermatomyositis (CADM), a subset of dermatomyositis characterized by a lack of muscle involvement, frequently develop rapidly progressive and treatment-resistant interstitial lung disease. We report the case of a 49-year-old man who was diagnosed with CADM. He developed interstitial pneumonia, which did not respond to combination therapy with methylprednisolone pulse therapy, cyclophosphamide, and cyclosporine. We therefore attempted plasma exchange. After 7 courses of therapeutic plasma exchange, the interstitial pneumonia gradually improved. This case suggests that plasma exchange might be an effective therapeutic option for patients with progressive interstitial lung disease in steroid- and immunosuppressive therapy-refractive CADM.
The cost and analysis of nonuse of cochlear implants.
Raine, Christopher H; Summerfield, Quentin; Strachan, David R; Martin, Jane M; Totten, Catherine
2008-02-01
Analysis of the cost implications and reasons for nonuse of cochlear implants in an established cochlear implant unit. Clinical data were analyzed retrospectively to construct a table of cochlear implant use over time to identify nonuse and to suggest the reasons for this. Yorkshire Cochlear Implant Service is a tertiary referral center. Three hundred forty consecutively implanted patients from 1990 to 2005. Life table analysis showed that most children used their implant (p = 0.7 during 11 yr). However, 11 of 155 children and 2 of 185 adults became nonusers during the period of study. The 11 children stopped because of age at implant, educational placement, and family support. Two adults stopped because of psychological issues and inability to adapt to the signal. Surgical and implant costs have initial impact, with subsequent years' costs reflecting programming issues and maintenance. When considering nonuse, there are 2 effects: first, no more costs are incurred, and second, no more years of use are accumulated. Thus, nonuse reduces both costs and years. Costs of gaining a year of use as a function of time showed that there was little financial impact from the 11 children nonusers. As a ratio of "no nonuse" and observed "nonuse" in children, the ratio is 1.07 by 13 years of implantation (7%). The adult group was too few to analyze. The nonuse added 7% to the average cost. Retrospective audit identifies that patient selection by a multidisciplinary team is crucial to reducing nonuse.
Al-Nawas, B; Groetz, K A; Goetz, H; Duschner, H; Wagner, W
2008-01-01
Test of favourable conditions for osseointegration with respect to optimum bone-implant contact (BIC) in a loaded animal model. The varied parameters were surface roughness and surface topography of commercially available dental implants. Thirty-two implants of six types of macro and microstructure were included in the study (total 196). The different types were: minimally rough control: Branemark machined Mk III; oxidized surface: TiUnite MkIII and MkIV; ZL Ticer; blasted and etched surface: Straumann SLA; rough control: titanium plasma sprayed (TPS). Sixteen beagle dogs were implanted with the whole set of the above implants. After a healing period of 8 weeks, implants were loaded for 3 months. For the evaluation of the BIC areas, adequately sectioned biopsies were visualized by subsurface scans with confocal laser scanning microscopy (CLSM). The primary statistical analysis testing BIC of the moderately rough implants (mean 56.1+/-13.0%) vs. the minimally rough and the rough controls (mean 53.9+/-11.2%) does not reveal a significant difference (P=0.57). Mean values of 50-70% BIC were found for all implant types. Moderately rough oxidized implants show a median BIC, which is 8% higher than their minimally rough turned counterpart. The intraindividual difference between the TPS and the blasted and etched counterparts revealed no significant difference. The turned and the oxidized implants show median values of the resonance frequency [implant stability quotients (ISQ)] over 60; the nonself-tapping blasted and etched and TPS implants show median values below 60. In conclusion, the benefit of rough surfaces relative to minimally rough ones in this loaded animal model was confirmed histologically. The comparison of different surface treatment modalities revealed no significant differences between the modern moderately rough surfaces. Resonance frequency analysis seems to be influenced in a major part by the transducer used, thus prohibiting the comparison of different implant systems.
Chou, Howard A; Zavitz, Daniel H; Ovadia, Marc
2003-01-01
To study in vivo modification of the SAM equivalent circuit when a highly ordered SAM is used as a bioelectrode, dodecanethiolate SAM-Au intramuscular electrodes were studied in living rat heart in a challenging in situ perfused rat model by impedance spectroscopy, cyclic voltammetry, and neutron activation analysis (NAA). The SAM layer experienced disintegration in vivo biological system, as NAA detected the presence of Au atoms that had leached into the surrounding living tissue. Therefore, the underlying Au surface became exposed during biological implant. Study by impedance spectroscopy, however, revealed perfect capacitive behavior for the SAM, similar to in vitro behavior. Electrodes showed a pure capacitive Nyquist plot with 86.1-89.4 degrees near-vertical line segments as the equivalent circuit locus, as for a parallel plate capacitor. Impedance magnitude varied linearly with 1/omega excluding diffusionally limited ionic charge transport. There was no diffusional conductive element Z(W infinity ) or spatially confined Warburg impedance Z(D). The effect of in vivo exposure of a highly ordered SAM is a 'sealing over' effect of new defects by the binding of proteinaceous or lipid species in the biological milieu, a fact of significance for SAM electrodes used either as pacemaker electrodes or as a platform for in vivo biosensors.
Computational study of hydroxyapatite structures, properties and defects
NASA Astrophysics Data System (ADS)
Bystrov, V. S.; Coutinho, J.; Bystrova, A. V.; Dekhtyar, Yu D.; Pullar, R. C.; Poronin, A.; Palcevskis, E.; Dindune, A.; Alkan, B.; Durucan, C.; Paramonova, E. V.
2015-03-01
Hydroxyapatite (HAp) was studied from a first principle approach using the local density approximation (LDA) method in AIMPRO code, in combination with various quantum mechanical (QM) and molecular mechanical (MM) methods from HypemChem 7.5/8.0. The data obtained were used for studies of HAp structures, the physical properties of HAp (density of electronic states—DOS, bulk modulus etc) and defects in HAp. Computed data confirmed that HAp can co-exist in different phases—hexagonal and monoclinic. Ordered monoclinic structures, which could reveal piezoelectric properties, are of special interest. The data obtained allow us to characterize the properties of the following defects in HAp: O, H and OH vacancies; H and OH interstitials; substitutions of Ca by Mg, Sr, Mn or Se, and P by Si. These properties reveal the appearance of additional energy levels inside the forbidden zone, shifts of the top of the valence band or the bottom of the conduction band, and subsequent changes in the width of the forbidden zone. The data computed are compared with other known data, both calculated and experimental, such as alteration of the electron work functions under different influences of various defects and treatments, obtained by photoelectron emission. The obtained data are very useful, and there is an urgent need for such analysis of modified HAp interactions with living cells and tissues, improvement of implant techniques and development of new nanomedical applications.
Ansari, Ghazaleh; Fattah-Alhosseini, Arash
2017-06-01
The effects of sever plastic deformation through multi-pass accumulative roll bonding on the passive and semiconducting behavior of pure titanium is evaluated in Ringer's physiological solution at 37°C in the present paper. Produced results by polarization plots and electrochemical impedance spectroscopy measurements revealed a significant advance in the passive response of the nano-grained sample compared to that of the annealed pure titanium. Also, Mott-Schottky test results of the nano-grained pure titanium represented a lower donor density and reduced flat-band potential in the formed passive film in comparison with the annealed sample. Moreover, based on the Mott-Schottky analysis in conjunction with the point defect model, it was suggested that with increase in formation potential, the calculated donor density of both annealed and nano-grained samples decreases exponentially and the thickness of the passive film linearly increases. These observations were consistent with the point defect model predictions, considering that the point defects within the passive film are metal interstitials, oxygen vacancies, or both. From the viewpoint of passive and semiconducting behavior, nano-grained pure titanium appeared to be more suitable for implant applications in simulate human body environment compared to annealed pure titanium. Copyright © 2017 Elsevier B.V. All rights reserved.
AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.
2016-01-01
SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force. PMID:28042449
Unified Approach to the Biomechanics of Dental Implantology
NASA Technical Reports Server (NTRS)
Grenoble, D. E.; Knoell, A. C.
1973-01-01
The human need for safe and effective dental implants is well-recognized. Although many implant designs have been tested and are in use today, a large number have resulted in clinical failure. These failures appear to be due to biomechanical effects, as well as biocompatibility and surgical factors. A unified approach is proposed using multidisciplinary systems technology, for the study of the biomechanical interactions between dental implants and host tissues. The approach progresses from biomechanical modeling and analysis, supported by experimental investigations, through implant design development, clinical verification, and education of the dental practitioner. The result of the biomechanical modeling, analysis, and experimental phases would be the development of scientific design criteria for implants. Implant designs meeting these criteria would be generated, fabricated, and tested in animals. After design acceptance, these implants would be tested in humans, using efficient and safe surgical and restorative procedures. Finally, educational media and instructional courses would be developed for training dental practitioners in the use of the resulting implants.
NASA Astrophysics Data System (ADS)
Corrêa, Cássia B.; Ramos, Nuno V.; Monteiro, Jaime; Vaz, Luis G.; Vaz, Mario A. P.
2012-10-01
The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.
Intraoral radiographs texture analysis for dental implant planning.
Mundim, Mayara B V; Dias, Danilo R; Costa, Ronaldo M; Leles, Cláudio R; Azevedo-Marques, Paulo M; Ribeiro-Rotta, Rejane F
2016-11-01
Computer vision extracts features or attributes from images improving diagnosis accuracy and aiding in clinical decisions. This study aims to investigate the feasibility of using texture analysis of periapical radiograph images as a tool for dental implant treatment planning. Periapical radiograph images of 127 jawbone sites were obtained before and after implant placement. From the superimposition of the pre- and post-implant images, four regions of interest (ROI) were delineated on the pre-implant images for each implant site: mesial, distal and apical peri-implant areas and a central area. Each ROI was analysed using Matlab® software and seven image attributes were extracted: mean grey level (MGL), standard deviation of grey levels (SDGL), coefficient of variation (CV), entropy (En), contrast, correlation (Cor) and angular second moment (ASM). Images were grouped by bone types-Lekholm and Zarb classification (1,2,3,4). Peak insertion torque (PIT) and resonance frequency analysis (RFA) were recorded during implant placement. Differences among groups were tested for each image attribute. Agreement between measurements of the peri-implant ROIs and overall ROI (peri-implant + central area) was tested, as well as the association between primary stability measures (PIT and RFA) and texture attributes. Differences among bone type groups were found for MGL (p = 0.035), SDGL (p = 0.024), CV (p < 0.001) and En (p < 0.001). The apical ROI showed a significant difference from the other regions for all attributes, except Cor. Concordance correlation coefficients were all almost perfect (ρ > 0.93), except for ASM (ρ = 0.62). Texture attributes were significantly associated with the implant stability measures. Texture analysis of periapical radiographs may be a reliable non-invasive quantitative method for the assessment of jawbone and prediction of implant stability, with potential clinical applications. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Saravana Kumar, Gurunathan; George, Subin Philip
2017-02-01
This work proposes a methodology involving stiffness optimization for subject-specific cementless hip implant design based on finite element analysis for reducing stress-shielding effect. To assess the change in the stress-strain state of the femur and the resulting stress-shielding effect due to insertion of the implant, a finite element analysis of the resected femur with implant assembly is carried out for a clinically relevant loading condition. Selecting the von Mises stress as the criterion for discriminating regions for elastic modulus difference, a stiffness minimization method was employed by varying the elastic modulus distribution in custom implant stem. The stiffness minimization problem is formulated as material distribution problem without explicitly penalizing partial volume elements. This formulation enables designs that could be fabricated using additive manufacturing to make porous implant with varying levels of porosity. Stress-shielding effect, measured as difference between the von Mises stress in the intact and implanted femur, decreased as the elastic modulus distribution is optimized.
NASA Astrophysics Data System (ADS)
Chan, Kwai S.; Koike, Marie; Mason, Robert L.; Okabe, Toru
2013-02-01
Additive layer deposition techniques such as electron beam melting (EBM) and laser beam melting (LBM) have been utilized to fabricate rectangular plates of Ti-6Al-4V with extra low interstitial (ELI) contents. The layer-by-layer deposition techniques resulted in plates that have different surface finishes which can impact significantly on the fatigue life by providing potential sites for fatigue cracks to initiate. The fatigue life of Ti-6Al-4V ELI alloys fabricated by EBM and LBM deposition techniques was investigated by three-point testing of rectangular beams of as-fabricated and electro-discharge machined surfaces under stress-controlled conditions at 10 Hz until complete fracture. Fatigue life tests were also performed on rolled plates of Ti-6Al-4V ELI, regular Ti-6Al-4V, and CP Ti as controls. Fatigue surfaces were characterized by scanning electron microscopy to identify the crack initiation site in the various types of specimen surfaces. The fatigue life data were analyzed statistically using both analysis of variance techniques and the Kaplan-Meier survival analysis method with the Gehan-Breslow test. The results indicate that the LBM Ti-6Al-4V ELI material exhibits a longer fatigue life than the EBM counterpart and CP Ti, but a shorter fatigue life compared to rolled Ti-6Al-4V ELI. The difference in the fatigue life behavior may be largely attributed to the presence of rough surface features that act as fatigue crack initiation sites in the EBM material.
Manor, Yifat; Chaushu, Gavriel; Lorean, Adi; Mijiritzky, Eithan
2015-01-01
To evaluate the survival rate of dental implants replacing failed implants in grafted maxillary sinuses using the lateral approach vs nongrafted posterior maxillae. A retrospective analysis was conducted to study the survival of secondary dental implants inserted in the posterior maxilla in previously failed implant sites between the years 2000 and 2010. The study group consisted of patients who had also undergone maxillary sinus augmentation, and the control group consisted of patients in whom implants in the posterior maxilla had failed. Clinical and demographic data were analyzed using a structured form. Seventy-five patients with a total of 75 replaced implants were included in the study. The study group comprised 40 patients and the control group, 35 patients. None of the replaced implants in the study group failed, resulting in an overall survival of 100%; three replaced implants in the control group failed (92% survival). The main reason for the primary implant removal was lack of osseointegration (35 [87.5%] of 40 study group implants and 23 [65.7%] of 35 control group implants [P = .027]). The difference between the groups with regard to the timing of primary implant failure was statistically significant. The study group had more early failures of the primary implant than did the control group (77% vs 62%; P = .038). Dental implants replaced in the posterior maxilla had a high survival rate. A higher rate of survival was found in augmented maxillary sinus sites. Within the limits of the present study, it can be concluded that previous implant failures in the grafted maxillary sinus should not discourage practitioners from a second attempt.
Mello, C C; Lemos, C A A; Verri, F R; Dos Santos, D M; Goiato, M C; Pellizzer, E P
2017-09-01
The aim of this systematic review and meta-analysis was to compare the survival rate of the implants and the peri-implant tissue changes associated with implants inserted in fresh extraction sockets and those inserted in healed sockets. This review has been registered at PROSPERO under the number CRD42016043309. A systematic search was conducted by two reviewers independently in the databases PubMed/MEDLINE, Embase, and the Cochrane Library using different search terms; articles published until November 2016 were searched for. The searches identified 30 eligible studies. A total of 3,049 implants were installed in a total of 1,435 patients with a mean age of 46.68 years and a minimum of 6 months of follow-up. The survival rate of delayed implants (98.38%) was significantly greater than immediate implants (95.21%) (p=.001). For the marginal bone loss (p=.32), implant stability quotients values (p=.44), and pocket probing depth (p=.94) there was no significant difference between the analysed groups. The immediate implants placed in fresh sockets should be performed with caution because of the significantly lower survival rates than delayed implants inserted in healed sockets. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Dissolution behavior and early bone apposition of calcium phosphate-coated machined implants
Hwang, Ji-Wan; Lee, Eun-Ung; Lee, Jung-Seok; Jung, Ui-Won; Lee, In-Seop
2013-01-01
Purpose Calcium phosphate (CaP)-coated implants promote osseointegration and survival rate. The aim of this study was to (1) analyze the dissolution behavior of the residual CaP particles of removed implants and (2) evaluate bone apposition of CaP-coated machined surface implants at the early healing phase. Methods Mandibular premolars were extracted from five dogs. After eight weeks, the implants were placed according to drilling protocols: a nonmobile implant (NI) group and rotational implant (RI) group. For CaP dissolution behavior analysis, 8 implants were removed after 0, 1, 2, and 4 weeks. The surface morphology and deposition of the coatings were observed. For bone apposition analysis, block sections were obtained after 1-, 2-, and 4-week healing periods and the specimens were analyzed. Results Calcium and phosphorus were detected in the implants that were removed immediately after insertion, and the other implants were composed mainly of titanium. There were no notable differences between the NI and RI groups in terms of the healing process. The bone-to-implant contact and bone density in the RI group showed a remarkable increase after 2 weeks of healing. Conclusions It can be speculated that the CaP coating dissolves early in the healing phase and chemically induces early bone formation regardless of the primary stability. PMID:24455442
Kwak, Mu-Seung; Kim, Seok-Gyu
2013-11-01
The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with Ø5.0 mm × 13.0 mm were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (α=.05) were done for statistical analysis. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.
2017-01-01
Purpose The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque. PMID:28462009
Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza
2016-04-01
The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.
Lee, Ji-Hye; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
2016-01-01
To evaluate the effect of implant coronal wall thickness on load-bearing capacity and screw joint stability. Experimental implants were customized after investigation of the thinnest coronal wall thickness of commercially available implant systems with a regular platform diameter. Implants with four coronal wall thicknesses (0.2, 0.3, 0.4, and 0.5 mm) were fabricated. Three sets of tests were performed. The first set was a failure test to evaluate load-bearing capacity and elastic limit. The second and third sets were cyclic and static loading tests. After abutment screw tightening of each implant, vertical cyclic loading of 250 N or static loading from 250 to 800 N was applied. Coronal diameter expansion, axial displacement, and removal torque values of the implants were compared. Repeated measures analysis of variance (ANOVA) was used for statistical analysis (α = .05). Implants with 0.2-mm coronal wall thickness demonstrated significantly low load-bearing capacity and elastic limit (both P < .05). These implants also showed significantly large coronal diameter expansion and axial displacement after screw tightening (both P < .05). Greater vertical load and thinner coronal wall thickness significantly increased coronal diameter expansion of the implant, axial displacement of the abutment, and removal torque loss of the abutment screw (all P < .05). Implant coronal wall thickness of 0.2 mm produces significantly inferior load-bearing capacity and screw joint stability.
Kopp, Sigmar; Behrend, Detlef; Kundt, Günther; Ottl, Peter; Frerich, Bernhard; Warkentin, Mareike
2013-06-01
To examine the influence of bone-substitute application during implantation on the success of immediately placed and loaded dental implants. A total of 147 consecutive patients (age, 16.5-80.4 years) were provided with 696 immediately loaded implants. The mean follow-up time was 34.1 months. Of these implants, 50.4% (n=351) were immediately placed into extraction sockets. A total of 119 implants were added by simultaneous bone-substitute application (NanoBone, Artoss GmbH, Rostock Germany), whereas the other implants were placed in healed bone. Univariate and multivariate analysis was performed using IBM SPSS V.20. The overall implant success rate was 96.1%. Implants with simultaneous bone replacement had a hazard ratio of 0.877 (p=0.837); 95% CI, 0.253-3.04). Factors found to be statistically significant modifiers of success on multivariate analysis (p<0.05) included type of superstructure (p<0.001), implant-abutment connection (p<0.001), membrane use (p=0.010), and jaw (p=0.026). None of the other factors investigated were significant modifiers. The present study demonstrates high success rates for immediately loaded implants and their superstructures independent of the simultaneous application of bone substitute. The declared aim of socket preservation, the prevention avoiding bone loss, is achieved in the immediate implant placement scenario under immediate-loading conditions.
A retrospective study on related factors affecting the survival rate of dental implants
Kang, Jeong-Kyung; Lee, Ki; Lee, Yong-Sang; Park, Pil-Kyoo
2011-01-01
PURPOSE The aim of this retrospective study is to analyze the relationship between local factors and survival rate of dental implant which had been installed and restored in Seoul Veterans Hospital dental center for past 10 years. And when the relationship is found out, it could be helpful to predict the prognosis of dental implants. MATERIALS AND METHODS A retrospective study of patients receiving root-shaped screw-type dental implants placed from January 2000 to December 2009 was conducted. 6385 implants were placed in 3755 patients. The following data were collected from the dental records and radiographs: patient's age, gender, implant type and surface, length, diameter, location of implant placement, bone quality, prosthesis type. The correlations between these data and survival rate were analyzed. Statistical analysis was performed with the use of Kaplan-Meier analysis, Chi-square test and odds ratio. RESULTS In all, 6385 implants were placed in 3755 patients (3120 male, 635 female; mean age 65 ± 10.58 years). 108 implants failed and the cumulative survival rate was 96.33%. There were significant differences in age, implant type and surface, length, location and prosthesis type (P<.05). No significant differences were found in relation to the following factors: gender, diameter and bone quality (P>.05). CONCLUSION Related factors such as age, implant type, length, location and prosthesis type had a significant effect on the implant survival. PMID:22259704
Dental implants typically help retain peri-implant vertical bone height: evidence-based analysis.
Greenstein, Gary; Cavallaro, John
2013-01-01
The dental literature is assessed regarding the ability of dental implants to maintain vertical bone height after various implant placement scenarios: immediate, delayed, insertion into partially and fully edentate healed ridges, and under overdentures. Studies are also reviewed to determine if bone loss after implant insertion is continuous. Numerous investigations that support the concept that implants preserve bone height are identified. In addition, the data indicate that a minuscule amount of annual bone loss usually persists after implant placement, but it is often clinically imperceptible.
Casting core for a cooling arrangement for a gas turbine component
Lee, Ching-Pang; Heneveld, Benjamin E
2015-01-20
A ceramic casting core, including: a plurality of rows (162, 166, 168) of gaps (164), each gap (164) defining an airfoil shape; interstitial core material (172) that defines and separates adjacent gaps (164) in each row (162, 166, 168); and connecting core material (178) that connects adjacent rows (170, 174, 176) of interstitial core material (172). Ends of interstitial core material (172) in one row (170, 174, 176) align with ends of interstitial core material (172) in an adjacent row (170, 174, 176) to form a plurality of continuous and serpentine shaped structures each including interstitial core material (172) from at least two adjacent rows (170, 174, 176) and connecting core material (178).
Cost-Effectiveness of Dental Implants: A Utility Analysis.
ERIC Educational Resources Information Center
Jacobson, J.; And Others
1990-01-01
A measure of dental patients' values and preferences was used to assess attitudes of 92 edentulous patients receiving implant and other dental reconstructive therapies. The implant group tended to be younger and better educated and to rate implant reconstruction as more desirable than the nonimplant denture group. (DB)
Interstitial lung disease induced by alectinib (CH5424802/RO5424802).
Ikeda, Satoshi; Yoshioka, Hiroshige; Arita, Machiko; Sakai, Takahiro; Sone, Naoyuki; Nishiyama, Akihiro; Niwa, Takashi; Hotta, Machiko; Tanaka, Tomohiro; Ishida, Tadashi
2015-02-01
A 75-year-old woman with anaplastic lymphoma kinase (ALK)-rearranged Stage IV lung adenocarcinoma was administered the selective anaplastic lymphoma kinase inhibitor, alectinib, as a third-line treatment in a Phase 1-2 study. On the 102nd day, chest computed tomography showed diffuse ground glass opacities. Laboratory data revealed high serum levels of KL-6, SP-D and lactate dehydrogenase without any clinical symptoms. There was no evidence of infection. Marked lymphocytosis was seen in bronchoalveolar lavage fluid analysis, and transbronchial lung biopsy showed mild thickening of alveolar septa and lymphocyte infiltration. Interstitial lung disease was judged to be related to alectinib based on improvements in imaging findings and serum biomarkers after discontinuation of alectinib. To our knowledge, this is the first reported case of alectinib-induced interstitial lung disease. Alectinib is a promising drug for ALK-rearranged non-small cell lung cancer. Clinical trials of this selective anaplastic lymphoma kinase inhibitor will facilitate the meticulous elucidation of its long-term safety profile. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Periapical implant lesion: A systematic review
Blaya-Tárraga, Juan-Antonio; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Peñarrocha-Diago, Miguel
2017-01-01
Background The aim of this study was to systematically review the evidence for periapical implant lesion, which makes a patient more susceptible to the periapical lesion, frequency, symptoms, signs (including radiological findings) and possible treatment options. Material and Methods A systematic literature review and analysis of publications included in PubMed, Embase and Cochrane; articles published until March 2016; with a populations, exposures and outcomes (PEO) search strategy was performed, focused on the issue: “In patients with periapical lesion to the implant during the osseointegration, what symptoms, signs, and changes in complementary examination manifested, for according to that stage, be intervened with the appropriate approach?”. The set criteria for inclusion were peer-reviewed articles. Results From a total of 212 papers identified, 36 studies were included in this systematic review, with 15461 implants evaluated and 183 periapical implant lesions. Which 8 papers included more than 5 cases and 28 included equal or less than 5 cases. Analysis of the papers revealed that periapical implant lesion is classified according to evolution stages into acute (non-suppurated and suppurated) and subacute (or suppurated-fistulized). In the acute stage and in the subacute if there is no loss of implant stability, the correct treatment approach is implant periapical surgery. In the subacute stage associated with implant mobility the implant must be removed. Conclusions Evidence on the subject is very limited, there are few studies with small sample, without homogeneity of criteria for diagnosing the disease and without design of scientific evidence. Currently etiology lacks consensus. The early diagnosis of periapical implant periapical lesions during the osseointegration phase and early treatment, will lead to a higher survival rate of implants treated, hence preventing the need for implant extraction. Key words:Apical peri-implantitis, retrograde peri-implantitis, inflammatory peri-implantitis lesion. PMID:29053646
Chrcanovic, B R; Kisch, J; Albrektsson, T; Wennerberg, A
2016-11-01
Recent studies have suggested that the insertion of dental implants in patients being diagnosed with bruxism negatively affected the implant failure rates. The aim of the present study was to investigate the association between the bruxism and the risk of dental implant failure. This retrospective study is based on 2670 patients who received 10 096 implants at one specialist clinic. Implant- and patient-related data were collected. Descriptive statistics were used to describe the patients and implants. Multilevel mixed effects parametric survival analysis was used to test the association between bruxism and risk of implant failure adjusting for several potential confounders. Criteria from a recent international consensus (Lobbezoo et al., J Oral Rehabil, 40, 2013, 2) and from the International Classification of Sleep Disorders (International classification of sleep disorders, revised: diagnostic and coding manual, American Academy of Sleep Medicine, Chicago, 2014) were used to define and diagnose the condition. The number of implants with information available for all variables totalled 3549, placed in 994 patients, with 179 implants reported as failures. The implant failure rates were 13·0% (24/185) for bruxers and 4·6% (155/3364) for non-bruxers (P < 0·001). The statistical model showed that bruxism was a statistically significantly risk factor to implant failure (HR 3·396; 95% CI 1·314, 8·777; P = 0·012), as well as implant length, implant diameter, implant surface, bone quantity D in relation to quantity A, bone quality 4 in relation to quality 1 (Lekholm and Zarb classification), smoking and the intake of proton pump inhibitors. It is suggested that the bruxism may be associated with an increased risk of dental implant failure. © 2016 John Wiley & Sons Ltd.
Surgical Tooth Implants, Combat and Field.
1983-07-15
The upper two parts of the implant (post and core and crown) are conventional dental materials, usually gold. EX) 1473 MrION Of" I POV GS IS O&SOLETE...10 Clinical Examples of Baboon Dental Implants . . . . . . . . . . . 12 Histologic Analysis of the Bone-Implant Interface . . . . . . . . 16...Aluminum Oxide Dental Implant . . . . . . . . . . 2 Figure 2. Clinical Photograph of A29 and A30 in Baboon 469 at Necropsy
Shao, Haiyu; Chen, Jinping; Ru, Bin; Yan, Feifei; Zhang, Jun; Xu, Shaonan; Huang, Yazeng
2015-09-17
Zero-profile implant has become more and more popular in anterior cervical discectomy and fusion (ACDF) for the treatment of degenerative cervical spondylosis. However, there was no enough evidence judging its efficiency and safety. The aim of this analysis was to evaluate the efficacy and safety of Zero-profile implant compared with conventional cage-plate (CCP) in ACDF. All studies directly comparing the outcomes between the Zero-profile implant and CCP implant in ACDF were included, and the search strategy followed the requirements of the Cochrane Library Handbook. Two of the authors extracted relevant data and checked the accuracy independently using standardized data collection form. Seven studies involving 560 patients were included, 262 in the Zero-profile group and 298 in the CCP group. Zero-profile implant had a lower rate of postoperative dysphagia at 2 weeks, 6 months, and 1 year (p = 0.0002, p = 0.008, and p = 0.001, respectively) than CCP implant. Zero-profile also reduced blood loss (p = 0.0001), while operation time and incidence of postoperative transient dysphagia had no statistical significance (p = 0.92, p = 0.42, respectively) between two groups. Based on the results of our analysis, the application of Zero-profile implant in ACDF had a lower rate of postoperative dysphagia at 2 weeks, 6 months, and 1 year than CCP implant. Zero-profile implant also had fewer blood loss during operation. More rigorous and adequately powered prospective randomized controlled trials with larger sample size are required to elucidate a more objective outcome.
Suskind, Anne M; Berry, Sandra H; Ewing, Brett A; Elliott, Marc N; Suttorp, Marika J; Clemens, J Quentin
2013-01-01
As part of the RICE (RAND Interstitial Cystitis Epidemiology) study, we developed validated case definitions to identify interstitial cystitis/bladder pain syndrome in women and chronic prostatitis/chronic pelvic pain syndrome in men. Using population based screening methods, we applied these case definitions to determine the prevalence of these conditions in men. A total of 6,072 households were contacted by telephone to screen for men who had symptoms of interstitial cystitis/bladder pain syndrome or chronic prostatitis/chronic pelvic pain syndrome. An initial 296 men screened positive, of whom 149 met the inclusionary criteria and completed the telephone interview. For interstitial cystitis/bladder pain syndrome 2 case definitions were applied (1 with high sensitivity and 1 with high specificity), while for chronic prostatitis/chronic pelvic pain syndrome a single case definition (with high sensitivity and specificity) was used. These case definitions were used to classify subjects into groups based on diagnosis. The interstitial cystitis/bladder pain syndrome weighted prevalence estimates for the high sensitivity and high specificity definitions were 4.2% (3.1-5.3) and 1.9% (1.1-2.7), respectively. The chronic prostatitis/chronic pelvic pain syndrome weighted prevalence estimate was 1.8% (0.9-2.7). These values equate to 1,986,972 (95% CI 966,042-2,996,924) men with chronic prostatitis/chronic pelvic pain syndrome and 2,107,727 (95% CI 1,240,485-2,974,969) men with the high specificity definition of interstitial cystitis/bladder pain syndrome in the United States. The overlap between men who met the high specificity interstitial cystitis/bladder pain syndrome case definition or the chronic prostatitis/chronic pelvic pain syndrome case definition was 17%. Symptoms of interstitial cystitis/bladder pain syndrome and chronic prostatitis/chronic pelvic pain syndrome are widespread among men in the United States. The prevalence of interstitial cystitis/bladder pain syndrome symptoms in men approaches that in women, suggesting that this condition may be underdiagnosed in the male population. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Display conditions and lesion detectability: effect of background light
NASA Astrophysics Data System (ADS)
Razavi, Mahmood; Hall, Theodore R.; Aberle, Denise R.; Hayrapetian, Alek S.; Loloyan, Mansur; Eldredge, Sandra L.
1990-08-01
We assessed the effect of high background light on observer performance for the detection of a variety of chest radiographic abnormalities. Five observers reviewed 66 digital hard copy chest images formatted to 1 1 x 14 inch size under two display conditions: 1) on a specially prepared 1 1 x 14 inch illuminated panel with no peripheral light and 2) on a standard viewing panel designed for 14 x 17 inch radiographs. The images contained one - or more of the following conditions: pneumothorax, interstitial disease, nodules, alveolar process, or no abnormality. The results of receiver operator characteristic analysis show that extraneous light does reduce observer performance and the detectability of nodules, interstitial disease.
Periventricular heterotopia in a boy with interstitial deletion of chromosome 4p.
Gawlik-Kuklinska, Katarzyna; Wierzba, Jolanta; Wozniak, Agnieszka; Iliszko, Mariola; Debiec-Rychter, Maria; Dubaniewicz-Wybieralska, Miroslawa; Limon, Janusz
2008-01-01
We report on a 4-year-old boy with a proximal interstitial deletion in the short arm of chromosome 4p with the karyotype 46,XY,del(4)(p14p15.32),inv(9)(p13q13). For a precise delineation of the deleted region, an array-based comparative genomic hybridization (a-CGH) analysis was performed. The proband's phenotype and cytogenetic findings are compared with previously reported cases with proximal 4p deletion syndrome. The syndrome is associated with normal growth, varying degrees of mental retardation, characteristic facial appearance and minor dysmorphic features. Additionally, our patient developed a seizure disorder due to abnormal neuronal migration, i.e., periventricular heterotopia.
NASA Astrophysics Data System (ADS)
Knutsen, K. E.; Galeckas, A.; Zubiaga, A.; Tuomisto, F.; Farlow, G. C.; Svensson, B. G.; Kuznetsov, A. Yu.
2012-09-01
By combining results from positron annihilation and photoluminescence spectroscopy with data from Hall effect measurements, the characteristic deep level emission centered at ˜1.75 eV and exhibiting an activation energy of thermal quenching of 11.5 meV is associated with the zinc vacancy. Further, a strong indication that oxygen interstitials act as a dominating acceptor is derived from the analysis of charge carrier losses induced by electron irradiation with variable energy below and above the threshold for Zn-atom displacement. We also demonstrate that the commonly observed green emission is related to an extrinsic acceptorlike impurity, which may be readily passivated by oxygen vacancies.
Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William
2017-11-01
Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Srinivasan, Murali; Vazquez, Lydia; Rieder, Philippe; Moraguez, Osvaldo; Bernard, Jean-Pierre; Belser, Urs C
2014-05-01
The aim of this review was to test the hypothesis that 6 mm micro-rough short Straumann(®) implants provide predictable survival rates and verify that most failures occurring are early failures. A PubMed and hand search was performed to identify studies involving micro-rough 6-mm-short implants published between January 1987 and August 2011. Studies were included that (i) involve Straumann(®) 6 mm implants placed in the human jaws, (ii) provide data on the survival rate, (iii) mention the time of failure, and (iv) report a minimum follow-up period of 12 months following placement. A meta-analysis was performed on the extracted data. From a total of 842 publications that were screened, 12 methodologically sound articles qualified to be included for the statistical evaluation based on our inclusion criteria. A total of 690 Straumann(®) 6-mm-short implants were evaluated in the reviewed studies (Total: placed-690, failed-25; maxilla: placed-266, failed-14; mandible: placed-364, failed-5; follow-up period: 1-8 years). A meta-analysis was performed on the calculated early cumulative survival rates (CSR%). The pooled early CSR% calculated in this meta-analysis was 93.7%, whereas the overall survival rates in the maxilla and mandible were 94.7% and 98.6% respectively. Implant failures observed were predominantly early failures (76%). This meta-analysis provides robust evidence that micro-rough 6-mm-short dental implants are a predictable treatment option, providing favorable survival rates. The failures encountered with 6-mm-short implants were predominantly early and their survival in the mandible was slightly superior. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
Abutment Disconnection/Reconnection Affects Peri-implant Marginal Bone Levels: A Meta-Analysis.
Koutouzis, Theofilos; Gholami, Fatemeh; Reynolds, John; Lundgren, Tord; Kotsakis, Georgios A
Preclinical and clinical studies have shown that marginal bone loss can be secondary to repeated disconnection and reconnection of abutments that affect the peri-implant mucosal seal. The aim of this systematic review and meta-analysis was to evaluate the impact of abutment disconnections/reconnections on peri-implant marginal bone level changes. To address this question, two reviewers independently performed an electronic search of three major databases up to October 2015 complemented by manual searches. Eligible articles were selected on the basis of prespecified inclusion and exclusion criteria after a two-phase search strategy and assessed for risk of bias. A random-effects meta-analysis was performed for marginal bone loss. The authors initially identified 392 titles and abstracts. After evaluation, seven controlled clinical studies were included. Qualitative assessment of the articles revealed a trend toward protective marginal bone level preservation for implants with final abutment placement (FAP) at the time of implant placement compared with implants for which there were multiple abutment placements (MAP). The FAP group exhibited a marginal bone level change ranging from 0.08 to 0.34 mm, whereas the MAP group exhibited a marginal bone level change ranging from 0.09 to 0.55 mm. Meta-analysis of the seven studies reporting on 396 implants showed significantly greater bone loss in cases of multiple abutment disconnections/reconnections. The weighted mean difference in marginal bone loss was 0.19 mm (95% confidence interval, 0.06-0.32 mm), favoring bone preservation in the FAP group. Within the limitations of this meta-analysis, abutment disconnection and reconnection significantly affected peri-implant marginal bone levels. These findings pave the way for revisiting current restorative protocols at the restorative treatment planning stage to prevent incipient marginal bone loss.
Lavigne, Eric; Holowaty, Eric J; Pan, Sai Yi; Villeneuve, Paul J; Johnson, Kenneth C; Fergusson, Dean A; Morrison, Howard; Brisson, Jacques
2013-04-29
To evaluate whether the stage distribution among women diagnosed as having breast cancer differs between those who have received breast implants for cosmetic purposes and those with no implants and to evaluate whether cosmetic breast augmentation before the detection of breast cancer is a predictor of post-diagnosis survival. Systematic review of observational studies with two meta-analyses. Systematic search of the literature published before September 2012 conducted in Medline, Embase, Global health, CINAHL, IPAB, and PsycINFO. Eligible publications were those that included women diagnosed as having breast cancer and who had had augmentation mammaplasty for cosmetic purposes. The overall odds ratio of the first meta-analysis based on 12 studies was 1.26 (95% confidence interval 0.99 to 1.60; P=0.058; I(2)=35.6%) for a non-localized stage of breast cancer at diagnosis comparing women with implants who had breast cancer and women without implants who had breast cancer. The second meta-analysis, based on five studies, evaluated the relation between cosmetic breast implantation and survival. This meta-analysis showed reduced survival after breast cancer among women who had implants compared with those who did not (overall hazard ratio for breast cancer specific mortality 1.38, 95% confidence interval 1.08 to 1.75). The research published to date suggests that cosmetic breast augmentation adversely affects the survival of women who are subsequently diagnosed as having breast cancer. These findings should be interpreted with caution, as some studies included in the meta-analysis on survival did not adjust for potential confounders. Further investigations are warranted regarding diagnosis and prognosis of breast cancer among women with breast implants.
Hernández-Cortés, Pedro; Monje, Alberto; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Mesa, Francisco; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David; O'Valle, Francisco
2014-01-01
This study was designed to explore relationships of resonance frequency analysis (RFA)-assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies.
Scanning electron microscopy fractography analysis of fractured hollow implants.
Sbordone, Ludovico; Traini, Tonino; Caputi, Sergio; Scarano, Antonio; Bortolaia, Claudia; Piattelli, Adriano
2010-01-01
Fracture of the implant is one of the possible complications affecting dental implants; it is a rare event but of great clinical relevance. The aim of the present study was to perform a scanning electron microscopy (SEM) fractography evaluation of 7 International Team for oral Implantology (ITI) hollow implants removed because of fracture. The most common clinical risk factors, such as malocclusion, bruxism, and cantilevers on the prosthesis, were absent. Seven fractured ITI hollow implants were retrieved from 5 patients and were analyzed with the use of SEM. SEM analysis showed typical signs of a cleavage-type fracture. Fractures could be due to an association of multiple factors such as fatigue, inner defects, material electrochemical problems, and tensocorrosion.
Comparative analysis of numerical and experimental data of orthodontic mini-implants.
Chatzigianni, Athina; Keilig, Ludger; Duschner, Heinz; Götz, Hermann; Eliades, Theodore; Bourauel, Christoph
2011-10-01
The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, 1.5 × 9 mm, and 2 × 7 mm). Mini-implants were inserted in two different ways, perpendicular to the bone surface or at 45 degrees to the direction of the applied load. Loading and boundary conditions in the FE models were adjusted to match the experimental situation, with the force applied on the neck of the mini-implants, along the mesio-distal direction up to a maximum of 0.5 N. Displacement and rotation of mini-implants after force application calculated by FEA were compared to previously recorded experimental deflections of the same mini-implants. Analysis of data with the Altman-Bland test and the Youden plot demonstrated good agreement between numerical and experimental findings (P = not significant) for the models selected. This study provides further evidence of the appropriateness of the FEA as an investigational tool in relevant research.
Byun, Soo-Jung; Heo, Seok-Mo; Ahn, Seung-Geun; Chang, Moontaek
2015-06-01
The aim was to analyze influential factors and effects of proximal contact loss between implant-supported fixed dental prostheses (FDP) and adjacent teeth. Ninety-four subjects treated with 135 FDPs supported by 188 implants were included. Degree of proximal contact tightness, food impaction, and periodontal/peri-implant tissue conditions were assessed in 191 proximal embrasures between implant-supported FDPs and adjacent teeth. Potential factors influencing proximal contact loss were estimated with the generalized estimation equation (GEE) procedure. Thirty-four percent of the proximal embrasures between implant-supported FDPs and teeth lost a proximal contact. The proximal contact loss rate continuously increased over the follow-up periods. A longer follow-up period, splinted implants, and mesial aspect of proximal contact were significant factors influencing the proximal contact loss in the univariate GEE analysis, whereas a longer follow-up period was the only significant factor in the multivariate GEE analysis. Food impaction was more frequently reported in the proximal contact loss group than the proximal contact group (odds ratio: 2.2). However, the proximal contact loss did not appear to affect the periodontal/peri-implant tissue conditions. Proximal contact loss between implant-supported FDPs and teeth occurred frequently and increased continuously over the follow-up period. The proximal contact loss significantly affected food impaction, but not the periodontal/peri-implant tissue conditions. Proximal contact loss should be carefully monitored during follow-up examinations in relation to food impaction. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.
Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René
2017-06-01
Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.
Towner, Rheal A; Wisniewski, Amy B; Wu, Dee H; Van Gordon, Samuel B; Smith, Nataliya; North, Justin C; McElhaney, Rayburt; Aston, Christopher E; Shobeiri, S Abbas; Kropp, Bradley P; Greenwood-Van Meerveld, Beverley; Hurst, Robert E
2016-03-01
Interstitial cystitis/bladder pain syndrome is a bladder pain disorder associated with voiding symptomatology and other systemic chronic pain disorders. Currently diagnosing interstitial cystitis/bladder pain syndrome is complicated as patients present with a wide range of symptoms, physical examination findings and clinical test responses. One hypothesis is that interstitial cystitis symptoms arise from increased bladder permeability to urine solutes. This study establishes the feasibility of using contrast enhanced magnetic resonance imaging to quantify bladder permeability in patients with interstitial cystitis. Permeability alterations in bladder urothelium were assessed by intravesical administration of the magnetic resonance imaging contrast agent Gd-DTPA (Gd-diethylenetriaminepentaacetic acid) in a small cohort of patients. Magnetic resonance imaging signal intensity in patient and control bladders was compared regionally and for entire bladders. Quantitative assessment of magnetic resonance imaging signal intensity indicated a significant increase in signal intensity in anterior bladder regions compared to posterior regions in patients with interstitial cystitis (p <0.01) and significant increases in signal intensity in anterior bladder regions (p <0.001). Kurtosis (shape of probability distribution) and skewness (measure of probability distribution asymmetry) were associated with contrast enhancement in total bladders in patients with interstitial cystitis vs controls (p <0.05). Regarding symptomatology interstitial cystitis cases differed significantly from controls on the SF-36®, PUF (Pelvic Pain and Urgency/Frequency) and ICPI (Interstitial Cystitis Problem Index) questionnaires with no overlap in the score range in each group. ICSI (Interstitial Cystitis Symptom Index) differed significantly but with a slight overlap in the range of scores. Data suggest that contrast enhanced magnetic resonance imaging provides an objective, quantifiable measurement of bladder permeability that could be used to stratify bladder pain patients and monitor therapy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Numerical Modeling of Fluid Flow in Solid Tumors
Soltani, M.; Chen, P.
2011-01-01
A mathematical model of interstitial fluid flow is developed, based on the application of the governing equations for fluid flow, i.e., the conservation laws for mass and momentum, to physiological systems containing solid tumors. The discretized form of the governing equations, with appropriate boundary conditions, is developed for a predefined tumor geometry. The interstitial fluid pressure and velocity are calculated using a numerical method, element based finite volume. Simulations of interstitial fluid transport in a homogeneous solid tumor demonstrate that, in a uniformly perfused tumor, i.e., one with no necrotic region, because of the interstitial pressure distribution, the distribution of drug particles is non-uniform. Pressure distribution for different values of necrotic radii is examined and two new parameters, the critical tumor radius and critical necrotic radius, are defined. Simulation results show that: 1) tumor radii have a critical size. Below this size, the maximum interstitial fluid pressure is less than what is generally considered to be effective pressure (a parameter determined by vascular pressure, plasma osmotic pressure, and interstitial osmotic pressure). Above this size, the maximum interstitial fluid pressure is equal to effective pressure. As a consequence, drugs transport to the center of smaller tumors is much easier than transport to the center of a tumor whose radius is greater than the critical tumor radius; 2) there is a critical necrotic radius, below which the interstitial fluid pressure at the tumor center is at its maximum value. If the tumor radius is greater than the critical tumor radius, this maximum pressure is equal to effective pressure. Above this critical necrotic radius, the interstitial fluid pressure at the tumor center is below effective pressure. In specific ranges of these critical sizes, drug amount and therefore therapeutic effects are higher because the opposing force, interstitial fluid pressure, is low in these ranges. PMID:21673952
Influence of interstitial Mn on magnetism in the room-temperature ferromagnet Mn 1 + δ Sb
Taylor, Alice E.; Berlijn, Tom; Hahn, Steven E.; ...
2015-06-15
We repormore » t elastic and inelastic neutron scattering measurements of the high-TC ferromagnet Mn 1 + δ Sb . Measurements were performed on a large, T C = 434 K, single crystal with interstitial Mn content of δ ≈ 0.13. The neutron diffraction results reveal that the interstitial Mn has a magnetic moment, and that it is aligned antiparallel to the main Mn moment. We perform density functional theory calculations including the interstitial Mn, and find the interstitial to be magnetic in agreement with the diffraction data. The inelastic neutron scattering measurements reveal two features in the magnetic dynamics: i) a spin-wave-like dispersion emanating from ferromagnetic Bragg positions (H K 2n), and ii) a broad, non-dispersive signal centered at forbidden Bragg positions (H K 2n+1). The inelastic spectrum cannot be modeled by simple linear spin-wave theory calculations, and appears to be significantly altered by the presence of the interstitial Mn ions. Finally, the results show that the influence of the interstitial Mn on the magnetic state in this system is more important than previously understood.« less
The pulmonary histopathology of anti-KS transfer RNA synthetase syndrome.
Schneider, Frank; Aggarwal, Rohit; Bi, David; Gibson, Kevin; Oddis, Chester; Yousem, Samuel A
2015-01-01
The clinical spectrum of the antisynthetase syndromes (AS) has been poorly defined, although some frequently present with pulmonary manifestations. The anti-KS anti-asparaginyl-transfer RNA synthetase syndrome is one in which pulmonary interstitial lung disease is almost always present and yet the histopathologic spectrum is not well described. To define the morphologic manifestations of pulmonary disease in those patients with anti-KS antiasparaginyl syndrome. We reviewed the connective tissue disorder registry of the University of Pittsburgh and identified those patients with anti-KS autoantibodies who presented with interstitial lung disease and had surgical lung biopsies. The 5 patients with anti-KS antisynthetase syndrome were usually women presenting with dyspnea and without myositis, but with mechanic's hands (60%) and Raynaud phenomenon (40%). They most often presented with a usual interstitial pneumonia pattern of fibrosis (80%), with the final patient displaying organizing pneumonia. Pulmonary interstitial lung disease is a common presentation in patients with the anti-KS-antisynthetase syndrome, who are often women with rather subtle or subclinical connective tissue disease, whereas the literature emphasizes the nonspecific interstitial pneumonia pattern often diagnosed clinically. Usual interstitial pneumonia and organizing pneumonia patterns of interstitial injury need to be added to this clinical differential diagnosis.
Khoshhal, Masoumeh; Vafaei, Fariborz; Najafi, Mahsa; Nikkhah, Masoumeh
2018-01-01
Background. In successful replacement of a tooth with a dental implant, soft tissue esthetic is as important as stability and function of the implant. Quality and quantity of the peri-implant mucosa can influence esthetic outcomes. This study assessed implant esthetic success of two different implant systems. In this regard the interdental papilla was evaluated and the relation-ship between implant type and crestal bone loss adjacent to implant was assessed. Methods. Eighteen patients (11 males, 7 females) with a total of 18 implants participated in this historical cohort study. Patients were divided into two groups based on the type of implants: Implantium group and SPI group; 36 interproximal papillae were evaluated photographically, using Jemt’s papillary presence index (PPI). Radiographic analysis was carried out to find out the relation between bone loss and type of implant. Analysis of data was performed with SPSS 18, using Fisher's exact test, independent t-test, Spearman's correlation coefficient and ANOVA. Results. Comparison of photographs did not show a statistically significant difference in PPI between the two groups (P=0.94). Radiographic evaluation of crestal bone loss adjacent to implant shoulder did not reveal significant differences between the two groups (P=0.30). Conclusion. Implant therapy in the anterior maxilla, using Implantium or SPI system, did not result in significant differences in esthetics. In this study, there was an inverse relationship between the distance of contact point to bone crest and papilla index (P=0.002 in the SPI group) (P=0.02 in the Implantium group). PMID:29732019
Risk indicators related to peri-implant disease: an observational retrospective cohort study
2016-01-01
Purpose The aim of the present study was to retrospectively investigate the influence of potential risk indicators on the development of peri-implant disease. Methods Overall, 103 patients referred for implant treatment from 2000 to 2012 were randomly enrolled. The study sample consisted of 421 conventional-length (>6 mm) non-turned titanium implants that were evaluated clinically and radiographically according to pre-established clinical and patient-related parameters by a single investigator. A non-parametric Mann-Whitney U test or Kruskal-Wallis rank test and a logistic regression model were used for the statistical analysis of the recorded data at the implant level. Results The diagnosis of peri-implant mucositis and peri-implantitis was made for 173 (41.1%) and 19 (4.5%) implants, respectively. Age (≥65 years), patient adherence (professional hygiene recalls <2/year) and the presence of plaque were associated with higher peri-implant probing-depth values and bleeding-on-probing scores. The logistic regression analysis indicated that age (P=0.001), patient adherence (P=0.03), the absence of keratinized tissue (P=0.03), implants placed in pristine bone (P=0.04), and the presence of peri-implant soft-tissue recession (P=0.000) were strongly associated with the event of peri-implantitis. Conclusions Within the limitations of this study, patients aged ≥65 years and non-adherent subjects were more prone to develop peri-implant disease. Therefore, early diagnosis and a systematic maintenance-care program are essential for maintaining peri-implant tissue health, especially in older patients. PMID:27588216
Yoon, Kyung-Ho; Kim, Su-Gwan; Lee, Jeong-Hoon; Suh, Seung-Woo
2011-10-01
The effect of stress levels and distributions around the internal nonsubmerged type implants after vertical bone resorption was investigated in this study. An HSII implant was placed in 4 cylindrical alveolar bone models with differing degrees of thread exposures. The load applied to each implant was von Mises stress and principal stress, 250 N in axial direction and 30 degrees lateral pressure. The difference in the load between the bone and the connective portion of the implant was obtained using ANSYS analysis. Bone loss in the cervical area of the implant was more obvious under lateral pressure. When more threads were exposed, bone level decreased and the maximum load applied on the fixture increased. It was concluded that higher bone level has a biomechanical advantage with respect to stress concentration.
NASA Astrophysics Data System (ADS)
Kamioka, K.; Oga, T.; Izawa, Y.; Kuriyama, K.; Kushida, K.; Kinomura, A.
2014-08-01
The displacement of oxygen lattices in Ge ion-implanted ZnO bulk single crystals is studied by nuclear reaction analysis (NAR), photoluminescence (PL), and Van der Pauw methods. The Ge ion-implantation (net concentration: 2.6 × 1020 cm-3) into ZnO is performed using a multiple-step energy. The high resistivity of ∼103 Ω cm in un-implanted samples remarkably decreased to ∼10-2 Ω cm after implanting Ge-ion and annealing subsequently. NRA measurements of as-implanted and annealed samples suggest the existence of the lattice displacement of O atoms acting as acceptor defects. As O related defects still remain after annealing, these defects are not attributed to the origin of the low resistivity in 800 and 1000 °C annealed ZnO.
Friction wear and auger analysis of iron implanted with 1.5-MeV nitrogen ions
NASA Technical Reports Server (NTRS)
Ferrante, J.; Jones, W. R., Jr.
1982-01-01
The effect of implantation of 1.5-MeV nitrogen ions on the friction and wear characteristics of pure iron sliding against steel was studied in a pin-on disk apparatus. An implantation dose of 5 x 10 to the 17th power ions/sq cm was used. Small reductions in initial and steady-state wear rates were observed for nitrogen-implanted iron riders as compared with unimplanted controls. Auger electron spectroscopy revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 15 at. % at a depth of 8 x 10 to the -7th m. A similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration, thus giving no evidence for diffusion of nitrogen beyond the implanted range.
Efanov, J I; Giot, J P; Fernandez, J; Danino, M A
2017-06-01
Macro-texturing of breast implants was developed with the double goal of improving implant stabilization within the breast cavity and decreasing the rate of capsular contractures. However, recent evidence suggests that double capsular formation, a potentially worrisome phenomenon associated with late seromas and biofilms, occurs with preponderance in macro-textured implants. Our objective was to analyze histologically different regions of double capsules to determine if they are more prone to mechanical movements. A prospective analysis including patients undergoing second-stage expander to definitive breast-implant reconstruction post-mastectomy was conducted after intraoperative identification of the double capsule phenomenon. Two samples were collected from each capsules around the implant, located centrally and laterally. The specimens were sent for histological analysis by the institution's pathologist. In total, 10 patients were identified intraoperatively with partial double capsule phenomenon. Among samples retrieved from the lateral aspect of the breast implant, all were associated with delamination and fractures in the collagen matrix of the double capsules. This phenomenon was not observed in any sample from the dome of the breast. Breast-implant macro-texturing plays an important role on delamination of capsules on lateral portions of the breast, which may have an etiologic role in double capsule formation. Manufacturing implants with macro-texturing on one side and smooth surface on the other could diminish mechanical shear forces responsible for these findings. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
A systematic review of implant outcomes in treated periodontitis patients.
Sousa, Vanessa; Mardas, Nikos; Farias, Bruna; Petrie, Aviva; Needleman, Ian; Spratt, David; Donos, Nikolaos
2016-07-01
To investigate the effect of treated periodontitis on implant outcomes in partially edentulous individuals compared with periodontally healthy patients. Longitudinal studies reporting on implant survival, success, incidence of peri-implantitis, bone loss and periodontal status, and on partially dentate patients with a history of treated periodontitis were included. The search yielded 14,917 citations. Twenty-seven publications met the inclusion criteria for qualitative data synthesis. Implant success and survival were higher in periodontally healthy patients, whilst bone loss and incidence of peri-implantitis was increased in patients with history of treated periodontitis. There was a higher tendency for implant loss and biological complications in patients previously presenting with severe forms of periodontitis. The strength of the evidence was limited by the heterogeneity of the included studies in terms of study design, population, therapy, unit of analysis, inconsistent definition of baselines and outcomes, as well as by the inadequate reporting of statistical analysis and accounting for confounding factors; thus, meta-analysis could not be performed. Implants placed in patients treated for periodontal disease are associated with higher incidence of biological complications and lower success and survival rates than those placed in periodontally healthy patients. Severe forms of periodontal disease are associated with higher rates of implant loss. However, it is critical to develop well-designed, long-term prospective studies to provide further substantive evidence on the association of these outcomes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Plasma immersion ion implantation for reducing metal ion release
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diaz, C.; Garcia, J. A.; Maendl, S.
Plasma immersion ion implantation of Nitrogen and Oxygen on CoCrMo alloys was carried out to improve the tribological and corrosion behaviors of these biomedical alloys. In order to optimize the implantation results we were carried experiments at different temperatures. Tribocorrosion tests in bovine serum were used to measure Co, Cr and Mo releasing by using Inductively Coupled Plasma Mass Spectrometry analysis after tests. Also, X-ray Diffraction analysis were employed in order to explain any obtained difference in wear rate and corrosion tests. Wear tests reveals important decreases in rate of more than one order of magnitude for the best treatment.more » Moreover decreases in metal release were found for all the implanted samples, preserving the same corrosion resistance of the unimplanted samples. Finally this paper gathers an analysis, in terms of implantation parameters and achieved properties for industrial implementation of these treatments.« less
Long-term results of uncemented alumina acetabular implants.
Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V
1994-01-01
We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.
Da Silva, John D; Kazimiroff, Julie; Papas, Athena; Curro, Frederick A; Thompson, Van P; Vena, Donald A; Wu, Hongyu; Collie, Damon; Craig, Ronald G
2014-07-01
The authors conducted a study to determine the types, outcomes, risk factors and esthetic assessment of implants and their restorations placed in the general practices of a practice-based research network. All patients who visited network practices three to five years previously and underwent placement of an implant and restoration within the practice were invited to enroll. Practitioner-investigators (P-Is) recorded the status of the implant and restoration, characteristics of the implant site and restoration, presence of peri-implant pathology and an esthetic assessment by the P-I and patient. The P-Is classified implants as failures if the original implant was missing or had been replaced, the implant was mobile or elicited pain on percussion, there was overt clinical or radiographic evidence of pathology or excessive bone loss (> 0.2 millimeter per year after an initial bone loss of 2 mm). They classified restorations as failures if they had been replaced or if there was abutment or restoration fracture. The authors enrolled 922 implants and patients from 87 practices, with a mean (standard deviation) follow-up of 4.2 (0.6) years. Of the 920 implants for which complete data records were available, 64 (7.0 percent) were classified as failures when excessive bone loss was excluded from the analysis. When excessive bone loss was included, 172 implants (18.7 percent) were classified as failures. According to the results of univariate analysis, a history of severe periodontitis, sites with preexisting inflammation or type IV bone, cases of immediate implant placement and placement in the incisor or canine region were associated with implant failure. According to the results of multivariate analysis, sites with preexisting inflammation (odds ratio [OR] = 2.17; 95 percent confidence interval [CI], 1.41-3.34]) or type IV bone (OR = 1.99; 95 percent CI, 1.12-3.55) were associated with a greater risk of implant failure. Of the 908 surviving implants, 20 (2.2 percent) had restorations replaced or judged as needing to be replaced. The majority of P-Is and patients were satisfied with the esthetic outcomes for both the implant and restoration. These results suggest that implant survival and success rates in general dental practices may be lower than those reported in studies conducted in academic or specialty settings. The results of this study, generated in the private general practice setting, add to the evidence base to facilitate implant treatment planning.
a Study of Oxygen Precipitation in Heavily Doped Silicon.
NASA Astrophysics Data System (ADS)
Graupner, Robert Kurt
Gettering of impurities with oxygen precipitates is widely used during the fabrication of semiconductors to improve the performance and yield of the devices. Since the effectiveness of the gettering process is largely dependent on the initial interstitial oxygen concentration, accurate measurements of this parameter are of considerable importance. Measurements of interstitial oxygen following thermal cycles are required for development of semiconductor fabrication processes and for research into the mechanisms of oxygen precipitate nucleation and growth. Efforts by industrial associations have led to the development of standard procedures for the measurement of interstitial oxygen in wafers. However practical oxygen measurements often do not satisfy the requirements of such standard procedures. An additional difficulty arises when the silicon wafer has a low resitivity (high dopant concentration). In such cases the infrared light used for the measurement is severely attenuated by the electrons of holes introduced by the dopant. Since such wafers are the substrates used for the production of widely used epitaxial wafers, this measurement problem is economically important. Alternative methods such as Secondary Ion Mass Spectroscopy or Gas Fusion Analysis have been developed to measure oxygen in these cases. However, neither of these methods is capable of distinguishing interstitial oxygen from precipitated oxygen as required for precipitation studies. In addition to the commercial interest in heavily doped silicon substrates, they are also of interest for research into the role of point defects in nucleation and precipitation processes. Despite considerable research effort, there is still disagreement concerning the type of point defect and its role in semiconductor processes. Studies of changes in the interstitial oxygen concentration of heavily doped and lightly doped silicon wafers could help clarify the role of point defects in oxygen nucleation and precipitation processes. This could lead to more effective control and use of oxygen precipitation for gettering. One of the principal purposes of this thesis is the extension of the infrared interstitial oxygen measurement technique to situations outside the measurement capacities of the standard technique. These situations include silicon slices exhibiting interfering precipitate absorption bands and heavily doped n-type silicon wafers. A new method is presented for correcting for the effect of multiple reflections in silicon wafers with optically rough surfaces. The technique for the measurement of interstitial oxygen in heavily doped n-type wafers is then used to perform a comparative study of oxygen precipitation in heavily antimony doped (.035 ohm-cm) silicon and lightly doped p-type silicon. A model is presented to quantitatively explain the observed suppression of defect formation in heavily doped n-type wafers.
Low-temperature irradiation-induced defects in germanium: In situ analysis
NASA Astrophysics Data System (ADS)
Mesli, A.; Dobaczewski, L.; Nielsen, K. Bonde; Kolkovsky, Vl.; Petersen, M. Christian; Larsen, A. Nylandsted
2008-10-01
The electronic properties of defects resulting from electron irradiation of germanium at low temperatures have been investigated. The recent success in preparing n+p junctions on germanium has opened a new opportunity to address fundamental questions regarding point defects and their related energy levels by allowing an access to the lower half of the band gap. In this work we apply various space-charge capacitance-transient spectroscopy techniques connected on line with the electron-beam facility. In n -type germanium we identify a level at about 0.14 eV below the conduction band whose properties resemble in many respects those of a defect assigned previously to the close vacancy-interstitial or Frenkel pair. This pair seems to annihilate over a small barrier at about 70 K, and its stability is particularly sensitive to the irradiation temperature and energy. We also observe two coupled levels at 0.08 and 0.24 eV below the conduction band stable up to 160 K. Recent independent theoretical work has predicted the existence of the single and double donor of the germanium interstitial with energy levels matching exactly these two values. Given these identifications hold, they mark a major difference with silicon where both the Frenkel pair and self-interstitial have never been caught. In p -type germanium, two levels were found. The shallower one, located at about 0.14 eV above the valence band, is tentatively assigned to the vacancy. It exhibits a field-driven instability at about 80 K making its analysis quite difficult. The application of a reverse bias, required by the space-charge spectroscopy, leads to a strong drift process sweeping this defect out of the observation area without necessarily provoking its annealing. Unlike silicon, in which the vacancy has four charge states, only one vacancy-related level seems to exist in germanium and this level is very likely a double acceptor. Finally, a very peculiar observation is made on a hole midgap trap, which, in many respects, behaves as the boron interstitial in silicon. This has led us to suggest that it may stem from the gallium interstitial, a natural dopant of our germanium materials, whose presence would be the fingerprint of the Watkins replacement mechanism in germanium.
Early diagnosis of orthopedic implant failure using macromolecular imaging agents.
Ren, Ke; Dusad, Anand; Zhang, Yijia; Purdue, P Edward; Fehringer, Edward V; Garvin, Kevin L; Goldring, Steven R; Wang, Dong
2014-08-01
To develop and evaluate diagnostic tools for early detection of wear particle-induced orthopaedic implant loosening. N-(2-Hydroxypropyl)methacrylamide (HPMA) copolymer was tagged with a near infrared dye and used to detect the inflammation induced by polymethylmethacrylate (PMMA) particles in a murine peri-implant osteolysis model. It was established by inserting an implant into the distal femur and challenging with routine PMMA particles infusion. The osteolysis was evaluated by micro-CT and histological analysis at different time points. Significant peri-implant osteolysis was found 3-month post PMMA particle challenge by micro-CT and histological analysis. At 1-month post challenge, when there was no significant peri-implant bone loss, the HPMA copolymer-near infrared dye conjugate was found to specifically target the femur with PMMA particles deposition, but not the contralateral control femur with phosphate buffered saline (PBS) infusion. The results from this study demonstrate the feasibility of utilizing the macromolecular diagnostic agent to detect particle-induced peri-implant inflammation prior to the development of detectable osteolysis. Recognition of this early pathological event would provide the window of opportunity for prevention of peri-implant osteolysis and subsequent orthopaedic implant failure.
A mathematical model of intestinal oedema formation.
Young, Jennifer; Rivière, Béatrice; Cox, Charles S; Uray, Karen
2014-03-01
Intestinal oedema is a medical condition referring to the build-up of excess fluid in the interstitial spaces of the intestinal wall tissue. Intestinal oedema is known to produce a decrease in intestinal transit caused by a decrease in smooth muscle contractility, which can lead to numerous medical problems for the patient. Interstitial volume regulation has thus far been modelled with ordinary differential equations, or with a partial differential equation system where volume changes depend only on the current pressure and not on updated tissue stress. In this work, we present a computational, partial differential equation model of intestinal oedema formation that overcomes the limitations of past work to present a comprehensive model of the phenomenon. This model includes mass and momentum balance equations which give a time evolution of the interstitial pressure, intestinal volume changes and stress. The model also accounts for the spatially varying mechanical properties of the intestinal tissue and the inhomogeneous distribution of fluid-leaking capillaries that create oedema. The intestinal wall is modelled as a multi-layered, deforming, poroelastic medium, and the system of equations is solved using a discontinuous Galerkin method. To validate the model, simulation results are compared with results from four experimental scenarios. A sensitivity analysis is also provided. The model is able to capture the final submucosal interstitial pressure and total fluid volume change for all four experimental cases, and provide further insight into the distribution of these quantities across the intestinal wall.
Chiba, Sahoko; Tsuchiya, Kimitake; Akashi, Takumi; Ishizuka, Masahiro; Okamoto, Tsukasa; Furusawa, Haruhiko; Tateishi, Tomoya; Kishino, Mitsuhiro; Miyazaki, Yasunari; Tateishi, Ukihide; Takemura, Tamiko; Inase, Naohiko
2016-06-01
Hypersensitivity pneumonitis (HP) is an interstitial lung disease caused by the inhalation of environmental antigens. The relationship between clinical, radiologic, and histopathologic findings of chronic HP remains unclear. Sixteen patients with proven chronic bird-related HP with a usual interstitial pneumonia-like pattern were analyzed retrospectively. Histopathologic findings were semiquantitatively assessed and compared with clinical and radiologic findings. We also evaluated the histopathologic findings affecting prognosis. The extent of centrilobular fibrosis was negatively correlated with Pao2 (r = -0.55, P = .03). The extent of bridging fibrosis was positively correlated with the ratio of maximal expiratory flow at 50% of forced vital capacity to that at 25% (r = 0.60, P = .02). Patients with a greater extent of fibroblastic foci (FF) had more radiologic reticulation (P = .01), honeycombing (P = .01), and traction bronchiectasis (P = .02), and had significantly shorter survival time (P = .01) than patients with a lesser extent of FF. Multivariate analysis showed that the extent of FF was a significant prognostic factor (hazard ratio, 2.36; 95% confidence interval, 1.02-5.48; P = .04). Our findings demonstrated that the extent of FF was significantly associated with reticulation, honeycombing, and traction bronchiectasis on high-resolution CT scanning. Moreover, the extent of FF could be a useful predictor of mortality in chronic HP with a usual interstitial pneumonia-like pattern. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.