Sample records for intra class correlation

  1. The inter and intra rater reliability of the Netball Movement Screening Tool.

    PubMed

    Reid, Duncan A; Vanweerd, Rebecca J; Larmer, Peter J; Kingstone, Rachel

    2015-05-01

    To establish the inter- and intra-rater reliability of the Netball Movement Screening Tool, for screening adolescent female netball players. Inter- and intra-rater reliability study. Forty secondary school netball players were recruited to take part in the study. Twenty subjects were screened simultaneously and independently by two raters to ascertain inter-rater agreement. Twenty subjects were scored by rater one on two occasions, separated by a week, to ascertain intra-rater agreement. Inter and intra-rater agreement was assessed utilising the two-way mixed inter class correlation coefficient and weighted kappa statistics. No significant demographic differences were found between the inter and intra-rater groups of subjects. Inter class correlation coefficients' demonstrated excellent inter-rater (two-way mixed inter class correlation coefficients 0.84, standard error of measurement 0.25) and intra-rater (two-way mixed inter class correlation coefficients 0.96, standard error of measurement 0.13) reliability for the overall Netball Movement Screening Tool score and substantial-excellent (two-way mixed inter class correlation coefficients 1.0-0.65) inter-rater and substantial-excellent intra-rater (two-way mixed inter class correlation coefficients 0.96-0.79) reliability for the component scores of the Netball Movement Screening Tool. Kappa statistic showed substantial to poor inter-rater (k=0.75-0.32) and intra-rater (k=0.77-0.27) agreement for individual tests of the NMST. The Netball Movement Screening Tool may be a reliable screening tool for adolescent netball players; however the individual test scores have low reliability. The screening tool can be administered reliably by raters with similar levels of training in the tool but variable clinical experience. On-going research needs to be undertaken to ascertain whether the Netball Movement Screening Tool is a valid tool in ascertaining increased injury risk for netball players. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Estimating a graphical intra-class correlation coefficient (GICC) using multivariate probit-linear mixed models.

    PubMed

    Yue, Chen; Chen, Shaojie; Sair, Haris I; Airan, Raag; Caffo, Brian S

    2015-09-01

    Data reproducibility is a critical issue in all scientific experiments. In this manuscript, the problem of quantifying the reproducibility of graphical measurements is considered. The image intra-class correlation coefficient (I2C2) is generalized and the graphical intra-class correlation coefficient (GICC) is proposed for such purpose. The concept for GICC is based on multivariate probit-linear mixed effect models. A Markov Chain Monte Carlo EM (mcm-cEM) algorithm is used for estimating the GICC. Simulation results with varied settings are demonstrated and our method is applied to the KIRBY21 test-retest dataset.

  3. Repeatability and reproducibility of corneal thickness using SOCT Copernicus HR.

    PubMed

    Vidal, Silvia; Viqueira, Valentín; Mas, David; Domenech, Begoña

    2013-05-01

    The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (S(W)) and the within-subject coefficient of variation (C(W)). The level of agreement by Bland-Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  4. Open source posturography.

    PubMed

    Rey-Martinez, Jorge; Pérez-Fernández, Nicolás

    2016-12-01

    The proposed validation goal of 0.9 in intra-class correlation coefficient was reached with the results of this study. With the obtained results we consider that the developed software (RombergLab) is a validated balance assessment software. The reliability of this software is dependent of the used force platform technical specifications. Develop and validate a posturography software and share its source code in open source terms. Prospective non-randomized validation study: 20 consecutive adults underwent two balance assessment tests, six condition posturography was performed using a clinical approved software and force platform and the same conditions were measured using the new developed open source software using a low cost force platform. Intra-class correlation index of the sway area obtained from the center of pressure variations in both devices for the six conditions was the main variable used for validation. Excellent concordance between RombergLab and clinical approved force platform was obtained (intra-class correlation coefficient =0.94). A Bland and Altman graphic concordance plot was also obtained. The source code used to develop RombergLab was published in open source terms.

  5. Intra- and inter-tester reliability and validity of normal finger size measurement using the Japanese ring gauge system.

    PubMed

    Suzuki, T; Sato, Y; Sotome, S; Arai, H; Arai, A; Yoshida, H

    2017-06-01

    This study was designed to investigate the reliability and validity of measurements of finger diameters with a ring gauge. A reliability study enrolled two independent samples (50 participants and seven examiners in Study I; 26 participants and 26 examiners in Study II). The sizes of each participant's little fingers were measured twice with a ring gauge by each examiner. To investigate the validity of the measurements, five hand therapists compared the finger size and hand volume of 30 participants with the ring gauge and with a figure-of-eight technique (Study III). The intra-class correlation coefficient for intra-observer reliability ranged from 0.97 to 0.99 in Study I, and 0.90 to 0.97 in Study II. The intra-class correlation coefficient for inter-observer reliability was 0.95 in Study I and 0.94 in Study II. The validity study showed a Pearson product moment correlation coefficient of 0.75. The ring gauge showed high reliability and validity for measurement of finger size. III, diagnostic.

  6. Face validity and reliability of a pictorial instrument for assessing fundamental movement skill perceived competence in young children.

    PubMed

    Barnett, Lisa M; Ridgers, Nicola D; Zask, Avigdor; Salmon, Jo

    2015-01-01

    To determine reliability and face validity of an instrument to assess young children's perceived fundamental movement skill competence. Validation and reliability study. A pictorial instrument based on the Test Gross Motor Development-2 assessed perceived locomotor (six skills) and object control (six skills) competence using the format and item structure from the physical competence subscale of the Pictorial Scale of Perceived Competence and Acceptance for Young Children. Sample 1 completed object control items in May (n=32) and locomotor items in October 2012 (n=23) at two time points seven days apart. Children were asked at the end of the test-retest their understanding of what was happening in each picture to determine face validity. Sample 2 (n=58) completed 12 items in November 2012 on a single occasion to test internal reliability only. Sample 1 children were aged 5-7 years (M=6.0, SD=0.8) at object control assessment and 5-8 years at locomotor assessment (M=6.5, SD=0.9). Sample 2 children were aged 6-8 years (M=7.2, SD=0.73). Intra-class correlations assessed in Sample 1 children were excellent for object control (intra-class correlation=0.78), locomotor (intra-class correlation=0.82) and all 12 skills (intra-class correlations=0.83). Face validity was acceptable. Internal consistency was adequate in both samples for each subscale and all 12 skills (alpha range 0.60-0.81). This study has provided preliminary evidence for instrument reliability and face validity. This enables future alignment between the measurement of perceived and actual fundamental movement skill competence in young children. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  7. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    PubMed

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  8. Valid statistical approaches for analyzing sholl data: Mixed effects versus simple linear models.

    PubMed

    Wilson, Machelle D; Sethi, Sunjay; Lein, Pamela J; Keil, Kimberly P

    2017-03-01

    The Sholl technique is widely used to quantify dendritic morphology. Data from such studies, which typically sample multiple neurons per animal, are often analyzed using simple linear models. However, simple linear models fail to account for intra-class correlation that occurs with clustered data, which can lead to faulty inferences. Mixed effects models account for intra-class correlation that occurs with clustered data; thus, these models more accurately estimate the standard deviation of the parameter estimate, which produces more accurate p-values. While mixed models are not new, their use in neuroscience has lagged behind their use in other disciplines. A review of the published literature illustrates common mistakes in analyses of Sholl data. Analysis of Sholl data collected from Golgi-stained pyramidal neurons in the hippocampus of male and female mice using both simple linear and mixed effects models demonstrates that the p-values and standard deviations obtained using the simple linear models are biased downwards and lead to erroneous rejection of the null hypothesis in some analyses. The mixed effects approach more accurately models the true variability in the data set, which leads to correct inference. Mixed effects models avoid faulty inference in Sholl analysis of data sampled from multiple neurons per animal by accounting for intra-class correlation. Given the widespread practice in neuroscience of obtaining multiple measurements per subject, there is a critical need to apply mixed effects models more widely. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Validation of the French version of the Burn Specific Health Scale-Brief (BSHS-B) questionnaire.

    PubMed

    Gandolfi, S; Auquit-Auckbur, I; Panunzi, S; Mici, E; Grolleau, J-L; Chaput, B

    2016-11-01

    The Burn Specific Health Scale-Brief questionnaire is a widely validated tool for estimating the health related quality of life and for assessing the best multidisciplinary management of burn patients. The aim of this study was to translate the BSHS-B into French and to investigate its reliability and validity. According to the procedure proposed by the Scientific Advisory Committee of the Medical Outcomes Trust, the Burn Specific Health Scale-Brief (BSHS-B) was translated from the English version into French. In order to test the reliability of the French version of the BSHS-B, 53 burn patients French speakers completed the BSHS-B and SF-36 questionnaires from two to four years after burn. Ten of them have been re-tested at 6 months after the first evaluation. To evaluate clinical utility of the BSHS-F, internal consistency, construct validity (using SF-36) and stability in time were assessed using Cronbach's alpha statistic, Spearman rank test, and intra-class correlation coefficient respectively. The French version of the BSHS-B Cronbach's alpha coefficient was 0.93 and was >0.80 for all the sub-domains. French version of the BSHS-B and the SF-36 were positively correlated, all the associations were statistically significant (p<0.01). Intra-class correlation coefficients for test-retest ranged between 0.95 and 0.99 for the sub-domains. The intra-class correlation coefficient (ICC) for the total score was 0.98. The French version of the BSHS-B shows a robust rate of internal consistency, construct validity and stability in time, supporting its application in routine clinical practice as well as in international studies. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  10. The accuracy of nurses' estimates of their absenteeism.

    PubMed

    Gaudine, Alice; Gregory, Connie

    2010-07-01

    The purpose of the present study was to determine the accuracy of nurses' self-reports of absence by examining: (1) the correlation, intra-class correlation, and Cronbach's alpha for self-reported absence and absence as reported in organizational records, (2) difference in central tendency for the two measures of absence and (3) the percentage of nurses who underestimate their absence. Research on nurses' absenteeism has often relied on self-reports of absence. However, nurses may not be aware of their actual absenteeism, or they may underestimate it. Self-reported absence from questionnaires completed by 215 Canadian nurses was compared with their absence from organizational records. There is a strong positive correlation, a strong intra-class correlation and Cronbach's alpha for the two measures of absence. However, there is a difference in central tendency that is related to the majority of nurses in this study (51.1%) underestimating their days absent from work. Research examining the predictors of absence may consider measuring absence with self-reports. Nevertheless, nurses demonstrated a bias to underestimate their absence. Feedback interventions to reduce absenteeism can be developed to include providing nurses with accurate information about their absence.

  11. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    PubMed

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  12. Intra-observer reproducibility and diagnostic performance of breast shear-wave elastography in Asian women.

    PubMed

    Park, Hye Young; Han, Kyung Hwa; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-06-01

    Our aim was to evaluate intra-observer reproducibility of shear-wave elastography (SWE) in Asian women. Sixty-four breast masses (24 malignant, 40 benign) were examined with SWE in 53 consecutive Asian women (mean age, 44.9 y old). Two SWE images were obtained for each of the lesions. The intra-observer reproducibility was assessed by intra-class correlation coefficients (ICC). We also evaluated various clinicoradiologic factors that can influence reproducibility in SWE. The ICC of intra-observer reproducibility was 0.789. In clinicoradiologic factor evaluation, masses surrounded by mixed fatty and glandular tissue (ICC: 0.619) showed lower intra-observer reproducibility compared with lesions that were surrounded by glandular tissue alone (ICC: 0.937; p < 0.05). Overall, the intra-observer reproducibility of breast SWE was excellent in Asian women. However, it may decrease when breast tissue is in a heterogeneous background. Therefore, SWE should be performed carefully in these cases. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    PubMed

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  14. [The reliability of a questionnaire regarding Colombian children's physical activity].

    PubMed

    Herazo-Beltrán, Aliz Y; Domínguez-Anaya, Regina

    2012-10-01

    Reporting the Physical Activity Questionnaire for school children's (PAQ-C) test-retest reliability and internal consistency. This was a descriptive study of 100 school-aged children aged 9 to 11 years old attending a school in Cartagena, Colombia. The sample was randomly selected. The PAQ-C was given twice, one week apart, after the informed consent forms had been signing by the children's parents and school officials. Cronbach's alpha coefficient of reliability was used for assessing internal consistency and an intra-class correlation coefficient for test-retest reliability SPSS (version 17.0) was used for statistical analysis. The questionnaire scored 0.73 internal consistencies during the first measurement and 0.78 on the second; intra-class correlation coefficient was 0.60. There were differences between boys and girls regarding both measurements. The PAQ-C had acceptable internal consistency and test-retest reliability, thereby making it useful for measuring children's self-reported physical activity and a valuable tool for population studies in Colombia.

  15. The Comprehensive Snack Parenting Questionnaire (CSPQ): Development and Test-Retest Reliability.

    PubMed

    Gevers, Dorus W M; Kremers, Stef P J; de Vries, Nanne K; van Assema, Patricia

    2018-04-26

    The narrow focus of existing food parenting instruments led us to develop a food parenting practices instrument measuring the full range of food practices constructs with a focus on snacking behavior. We present the development of the questionnaire and our research on the test-retest reliability. The developed Comprehensive Snack Parenting Questionnaire (CSPQ) covers 21 constructs. Test-retest reliability was assessed by calculating intra class correlation coefficients and percentage agreement after two administrations of the CSPQ among a sample of 66 Dutch parents. Test-retest reliability analysis revealed acceptable intra class correlation coefficients (≥0.41) or agreement scores (≥0.60) for all items. These results, together with earlier work, suggest sufficient psychometric characteristics. The comprehensive, but brief CSPQ opens up chances for highly essential but unstudied research questions to understand and predict children’s snack intake. Example applications include studying the interactional nature of food parenting practices or interactions of food parenting with general parenting or child characteristics.

  16. The sizing of hamstring grafts for anterior cruciate reconstruction: intra- and inter-observer reliability.

    PubMed

    Dwyer, Tim; Whelan, Daniel B; Khoshbin, Amir; Wasserstein, David; Dold, Andrew; Chahal, Jaskarndip; Nauth, Aaron; Murnaghan, M Lucas; Ogilvie-Harris, Darrell J; Theodoropoulos, John S

    2015-04-01

    The objective of this study was to establish the intra- and inter-observer reliability of hamstring graft measurement using cylindrical sizing tubes. Hamstring tendons (gracilis and semitendinosus) were harvested from ten cadavers by a single surgeon and whip stitched together to create ten 4-strand hamstring grafts. Ten sports medicine surgeons and fellows sized each graft independently using either hollow cylindrical sizers or block sizers in 0.5-mm increments—the sizing technique used was applied consistently to each graft. Surgeons moved sequentially from graft to graft and measured each hamstring graft twice. Surgeons were asked to state the measured proximal (femoral) and distal (tibial) diameter of each graft, as well as the diameter of the tibial and femoral tunnels that they would drill if performing an anterior cruciate ligament (ACL) reconstruction using that graft. Reliability was established using intra-class correlation coefficients. Overall, both the inter-observer and intra-observer agreement were >0.9, demonstrating excellent reliability. The inter-observer reliability for drill sizes was also excellent (>0.9). Excellent correlation was seen between cylindrical sizing, and drill sizes (>0.9). Sizing of hamstring grafts by multiple surgeons demonstrated excellent intra-observer and intra-observer reliability, potentially validating clinical studies exploring ACL reconstruction outcomes by hamstring graft diameter when standard techniques are used. III.

  17. Depth as an Organizing Force in Pocillopora damicornis: Intra-Reef Genetic Architecture

    PubMed Central

    Gorospe, Kelvin D.; Karl, Stephen A.

    2015-01-01

    Relative to terrestrial plants, and despite similarities in life history characteristics, the potential for corals to exhibit intra-reef local adaptation in the form of genetic differentiation along an environmental gradient has received little attention. The potential for natural selection to act on such small scales is likely increased by the ability of coral larval dispersal and settlement to be influenced by environmental cues. Here, we combine genetic, spatial, and environmental data for a single patch reef in Kāne‘ohe Bay, O‘ahu, Hawai‘i, USA in a landscape genetics framework to uncover environmental drivers of intra-reef genetic structuring. The genetic dataset consists of near-exhaustive sampling (n = 2352) of the coral, Pocillopora damicornis at our study site and six microsatellite genotypes. In addition, three environmental parameters – depth and two depth-independent temperature indices – were collected on a 4 m grid across 85 locations throughout the reef. We use ordinary kriging to spatially interpolate our environmental data and estimate the three environmental parameters for each colony. Partial Mantel tests indicate a significant correlation between genetic relatedness and depth while controlling for space. These results are also supported by multi-model inference. Furthermore, spatial Principle Component Analysis indicates a statistically significant genetic cline along a depth gradient. Binning the genetic dataset based on size-class revealed that the correlation between genetic relatedness and depth was significant for new recruits and increased for larger size classes, suggesting a possible role of larval habitat selection as well as selective mortality in structuring intra-reef genetic diversity. That both pre- and post-recruitment processes may be involved points to the adaptive role of larval habitat selection in increasing adult survival. The conservation importance of uncovering intra-reef patterns of genetic diversity is discussed. PMID:25806798

  18. Intra-rater Reliability of Arm and Hand Muscle Strength Measurements in Persons With Late Effects of Polio.

    PubMed

    Brogårdh, Christina; Flansbjer, Ulla-Britt; Carlsson, Håkan; Lexell, Jan

    2015-10-01

    Muscle weakness in the upper limb is common in persons with late effects of polio. To be able to measure muscle strength and follow changes over time, reliable measurements are needed. To evaluate the intra-rater reliability of isometric and isokinetic arm and hand muscle strength measurements in persons with late effects of polio. A test-retest design. A university hospital outpatient clinic. Twenty-eight persons (mean age 68 years, SD 11 years) with late effects of polio in their upper limbs. Isometric shoulder abduction, isokinetic concentric elbow flexion and extension, isometric elbow flexion, and isometric grip strength were measured twice, 14 days apart. Reliability was evaluated with the intra-class correlation coefficient, the mean difference between the test sessions (d¯), together with the 95% confidence intervals for d¯ , the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%), and Bland-Altman graphs. A fixed dynamometer (Biodex) was used to measure arm strength and an electronic dynamometer (GRIP-it) was used to measure grip strength. Intra-rater reliability was high, with intra-class correlation coefficients between 0.87 and 0.98. The SEM%, representing the smallest change for a group of persons, ranged from 7%-24% for all strength measurements, and the SRD%, representing the smallest change for an individual person, ranged from 20%-67%. Muscle strength in the upper limbs can be reliably measured in persons with late effects of polio. However, the measurement errors indicate that the method is more suitable to detect changes in muscle strength for a group of persons than for an individual person. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  19. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    PubMed

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to determine intra- and interobserver reliability, as well as accuracy, efficiency, and precision. Statistical analysis using the intra- and interclass correlation coefficient was calculated using R (version 3.3.2, 2016) to determine the degree of intra- and interobserver reliability. High rates of intra- and interobserver reliability were observed between the junior resident, senior resident, and attending surgeon when using the smartphone protractor application as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.874 respectively. High rates of inter- and intraobserver reliability were also seen between the junior resident, senior resident, and attending surgeon when a marker and protractor were used as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.807 respectively. The lumbar lordosis, pelvic incidence, and pelvic tilt values were accurately measured by all three raters, with excellent inter- and intra-class correlation coefficient values. When the first 10 radiographs were re-measured at different time points, a high degree of precision was noted. Measurements performed using the smartphone application were consistently faster than using a marker and protractor-this difference reached statistical significance of p<.05. Adult spinal deformity radiographic parameters can be measured accurately, precisely, reliably, and more efficiently using a smartphone protractor application than with a standard protractor and wax pencil. A high degree of intra- and interobserver reliability was seen between the residents and attending surgeon, indicating measurements made with a smartphone protractor are unaffected by an observer's level of experience. As a result, smartphone protractors may be used when planning ASD surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Concurrent validity of the Alberta Infant Motor Scale to detect delayed gross motor development in preterm infants: A comparative study with the Bayley III.

    PubMed

    Albuquerque, Plínio Luna de; Guerra, Miriam Queiroz de Farias; Lima, Marília de Carvalho; Eickmann, Sophie Helena

    2017-05-24

    To investigate the concurrent validity of AIMS in relation to the gross motor subtest of the Bayley Scale III/GM in preterm infants. A total of 159 gross motor development assessments were performed with the AIMS and Bayley-III/GM. Linear regression was used to assess the correlation between AIMS and Bayley-III/GM scores. The intra-class correlation coefficient (ICC) and the Bland-Altman plot were used to analyze intra- and inter-rater reliability. There was a prevalence of delayed gross motor development of 20.8% according to the Bayley-III/GM, and 11.9% for the 5th percentile and 21.4% for the 10th percentile of AIMS. A good correlation of AIMS with Bayley-III/GM scores and intra- and inter-rater reliability was encountered in this study. AIMS proved very capable of detecting delayed gross motor development in preterm infants when compared with the Bayley-III/GM. The 10th percentile of AIMS provided the best combination of indicators, with greater specificity.

  1. Automatic target recognition using a feature-based optical neural network

    NASA Technical Reports Server (NTRS)

    Chao, Tien-Hsin

    1992-01-01

    An optical neural network based upon the Neocognitron paradigm (K. Fukushima et al. 1983) is introduced. A novel aspect of the architectural design is shift-invariant multichannel Fourier optical correlation within each processing layer. Multilayer processing is achieved by iteratively feeding back the output of the feature correlator to the input spatial light modulator and updating the Fourier filters. By training the neural net with characteristic features extracted from the target images, successful pattern recognition with intra-class fault tolerance and inter-class discrimination is achieved. A detailed system description is provided. Experimental demonstration of a two-layer neural network for space objects discrimination is also presented.

  2. Judging in Rhythmic Gymnastics at Different Levels of Performance.

    PubMed

    Leandro, Catarina; Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta

    2017-12-01

    This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach's alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges' difficulty scores, the Kendall's coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach's alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level.

  3. Judging in Rhythmic Gymnastics at Different Levels of Performance

    PubMed Central

    Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta

    2017-01-01

    Abstract This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach’s alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges’ difficulty scores, the Kendall’s coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach’s alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level. PMID:29339996

  4. The functional significance of EEG microstates--Associations with modalities of thinking.

    PubMed

    Milz, P; Faber, P L; Lehmann, D; Koenig, T; Kochi, K; Pascual-Marqui, R D

    2016-01-15

    The momentary, global functional state of the brain is reflected by its electric field configuration. Cluster analytical approaches consistently extracted four head-surface brain electric field configurations that optimally explain the variance of their changes across time in spontaneous EEG recordings. These four configurations are referred to as EEG microstate classes A, B, C, and D and have been associated with verbal/phonological, visual, subjective interoceptive-autonomic processing, and attention reorientation, respectively. The present study tested these associations via an intra-individual and inter-individual analysis approach. The intra-individual approach tested the effect of task-induced increased modality-specific processing on EEG microstate parameters. The inter-individual approach tested the effect of personal modality-specific parameters on EEG microstate parameters. We obtained multichannel EEG from 61 healthy, right-handed, male students during four eyes-closed conditions: object-visualization, spatial-visualization, verbalization (6 runs each), and resting (7 runs). After each run, we assessed participants' degrees of object-visual, spatial-visual, and verbal thinking using subjective reports. Before and after the recording, we assessed modality-specific cognitive abilities and styles using nine cognitive tests and two questionnaires. The EEG of all participants, conditions, and runs was clustered into four classes of EEG microstates (A, B, C, and D). RMANOVAs, ANOVAs and post-hoc paired t-tests compared microstate parameters between conditions. TANOVAs compared microstate class topographies between conditions. Differences were localized using eLORETA. Pearson correlations assessed interrelationships between personal modality-specific parameters and EEG microstate parameters during no-task resting. As hypothesized, verbal as opposed to visual conditions consistently affected the duration, occurrence, and coverage of microstate classes A and B. Contrary to associations suggested by previous reports, parameters were increased for class A during visualization, and class B during verbalization. In line with previous reports, microstate D parameters were increased during no-task resting compared to the three internal, goal-directed tasks. Topographic differences between conditions included particular sub-regions of components of the metabolic default mode network. Modality-specific personal parameters did not consistently correlate with microstate parameters except verbal cognitive style which correlated negatively with microstate class A duration and positively with class C occurrence. This is the first study that aimed to induce EEG microstate class parameter changes based on their hypothesized functional significance. Beyond the associations of microstate classes A and B with visual and verbal processing, respectively, our results suggest that a finely-tuned interplay between all four EEG microstate classes is necessary for the continuous formation of visual and verbal thoughts. Our results point to the possibility that the EEG microstate classes may represent the head-surface measured activity of intra-cortical sources primarily exhibiting inhibitory functions. However, additional studies are needed to verify and elaborate on this hypothesis. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Assessment of lumbosacral kyphosis in spondylolisthesis: a computer-assisted reliability study of six measurement techniques

    PubMed Central

    Glavas, Panagiotis; Mac-Thiong, Jean-Marc; Parent, Stefan; de Guise, Jacques A.

    2008-01-01

    Although recognized as an important aspect in the management of spondylolisthesis, there is no consensus on the most reliable and optimal measure of lumbosacral kyphosis (LSK). Using a custom computer software, four raters evaluated 60 standing lateral radiographs of the lumbosacral spine during two sessions at a 1-week interval. The sample size consisted of 20 normal, 20 low and 20 high grade spondylolisthetic subjects. Six parameters were included for analysis: Boxall’s slip angle, Dubousset’s lumbosacral angle (LSA), the Spinal Deformity Study Group’s (SDSG) LSA, dysplastic SDSG LSA, sagittal rotation (SR), kyphotic Cobb angle (k-Cobb). Intra- and inter-rater reliability for all parameters was assessed using intra-class correlation coefficients (ICC). Correlations between parameters and slip percentage were evaluated with Pearson coefficients. The intra-rater ICC’s for all the parameters ranged between 0.81 and 0.97 and the inter-rater ICC’s were between 0.74 and 0.98. All parameters except sagittal rotation showed a medium to large correlation with slip percentage. Dubousset’s LSA and the k-Cobb showed the largest correlations (r = −0.78 and r = −0.50, respectively). SR was associated with the weakest correlation (r = −0.10). All other parameters had medium correlations with percent slip (r = 0.31–0.43). All measurement techniques provided excellent inter- and intra-rater reliability. Dubousset’s LSA showed the strongest correlation with slip grade. This parameter can be used in the clinical setting with PACS software capabilities to assess LSK. A computer-assisted technique is recommended in order to increase the reliability of the measurement of LSK in spondylolisthesis. PMID:19015898

  6. Excellent Intra and Inter-Observer Reproducibility of Wrist Circumference Measurements in Obese Children and Adolescents

    PubMed Central

    Campagna, Giuseppe; Zampetti, Simona; Gallozzi, Alessia; Giansanti, Sara; Chiesa, Claudio; Pacifico, Lucia; Buzzetti, Raffaella

    2016-01-01

    In a previous study, we found that wrist circumference, in particular its bone component, was associated with insulin resistance in a population of overweight/obese children. The aim of the present study was to evaluate the intra- and inter-operator variability in wrist circumference measurement in a population of obese children and adolescents. One hundred and two (54 male and 48 female) obese children and adolescents were consecutively enrolled. In all subjects wrist circumferences were measured by two different operators two times to assess intra- and inter-operator variability. Statistical analysis was performed using SAS v.9.4 and JMP v.12. Measurements of wrist circumference showed excellent inter-operator reliability with Intra class Correlation Coefficients (ICC) of 0.96 and ICC of 0.97 for the first and the second measurement, respectively. The intra-operator reliability was, also, very strong with a Concordance Correlation Coefficient (CCC) of 0.98 for both operators. The high reproducibility demonstrated in our results suggests that wrist circumference measurement, being safe, non-invasive and repeatable can be easily used in out-patient settings to identify youths with increased risk of insulin-resistance. This can avoid testing the entire population of overweight/obese children for insulin resistance parameters. PMID:27294398

  7. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    PubMed

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  8. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  9. A Multicenter Trial of the Proficiency of Smart Quantitative Sensation Tests

    PubMed Central

    Dyck, Peter J.; Argyros, Barbara; Russell, James W.; Gahnstrom, Linde E.; Nalepa, Susan; Albers, James W.; Lodermeier, Karen A.; Zafft, Andrew J.; Dyck, P. James B.; Klein, Christopher J.; Litchy, William J.; Davies, Jenny L.; Carter, Rickey E.; Melton, L. Joseph

    2014-01-01

    Introduction We assessed proficiency (accuracy and intra- and inter-test reproducibility) of smart quantitative sensation tests (smart QSTs) in subjects without and with diabetic polyneuropathy (DSPN). Methods Technologists from 3 medical centers using different but identical QSTs assessed independently 6 modalities of sensation of foot (or leg) twice in patients without (n = 6) and with (n = 6) DSPN using smart computer assisted QSTs. Results Low rates of test abnormalities were observed in health and high rates in DSPN. Very high intra-class correlations were obtained between continuous measures of QSTs and neuropathy signs, symptoms, or nerve conductions (NCs). No significant intra- or inter-test differences were observed. Discussion These results provide proof of concept that smart QSTs provide accurate assessment of sensation loss without intra- or inter-test differences useful for multicenter trials. Smart technology makes possible efficient testing of body surface area sensation loss in symmetric length-dependent sensorimotor polyneuropathies. PMID:23929701

  10. A controlled evaluation of oral screen effects on intra-oral pressure curve characteristics.

    PubMed

    Knösel, Michael; Jung, Klaus; Kinzinger, Gero; Bauss, Oskar; Engelke, Wilfried

    2010-10-01

    The purpose of this study was to quantify the impact of oral screen (OS) application on intra-oral pressure characteristics in three malocclusion groups. Fifty-six randomly recruited participants (26 males and 30 females) who met the inclusion criteria of either an Angle Class I occlusal relationships or Angle Class II1 or II2 malocclusions, were assigned by dentition to group I (n = 31), group II1 (n = 12), or group II2 (n = 13). Two 3 minute periods of intra-oral pressure monitoring were conducted on each participant, using two different oral end fittings connected to a piezo-resistive relative pressure sensor: (1) a flexible OS and (2) a small-dimensioned air-permeable end cap (EC), which was placed laterally in the premolar region, thus recording intra-oral pressure independent of the influence of the OS. Pressure curve characteristics for both periods and between the malocclusion groups were evaluated with reference to the frequency of swallowing peaks, duration, and altitude of negative pressure plateau phases and the area under the pressure curve. Statistical analysis was undertaken using analysis of variance (ANOVA), the Wilcoxon Mann-Whitney test, and spearman correlation coefficient. A median number of two peaks (median height -20.9 mbar) and three plateau phases (median height of -2.3 mbar) may be regarded as normative for normal occlusion subjects during a 3 minute period, at rest. OS application raised the median average duration and height of intra-oral negative pressure plateau phases in the II1 subjects, exceeding those of group I, but less than the plateau duration in group II2. Median peak heights were distinctively lower in groups I and II1 during OS application. It is concluded that additional training for extension of intra-oral pressure phases may be a promising approach to pre-orthodontic Class II division 1 treatment.

  11. Correlation and agreement between eplet mismatches calculated using serological, low-intermediate and high resolution molecular human leukocyte antigen typing methods.

    PubMed

    Fidler, Samantha; D'Orsogna, Lloyd; Irish, Ashley B; Lewis, Joshua R; Wong, Germaine; Lim, Wai H

    2018-03-02

    Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960-0.975) and 0.926 (95% CI 0.899-0.944), respectively; and 0.995 (95% CI 0.994-0.996) and 0.993 (95% CI 0.991-0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation.

  12. Comparison of Two Sources of Clinical Audit Data to Assess the Delivery of Diabetes Care in Aboriginal Communities.

    PubMed

    Regan, Timothy; Paul, Christine; Ishiguchi, Paul; D'Este, Catherine; Koller, Claudia; Forshaw, Kristy; Noble, Natasha; Oldmeadow, Christopher; Bisquera, Alessandra; Eades, Sandra

    2017-10-17

    The objective of this study was to determine the concordance between data extracted from two Clinical Decision Support Systems regarding diabetes testing and monitoring at Aboriginal Community Controlled Health Services in Australia. De-identified PenCAT and Communicare Systems data were extracted from the services allocated to the intervention arm of a diabetes care trial, and intra-class correlations for each extracted item were derived at a service level. Strong to very strong correlations between the two data sources were found regarding the total number of patients with diabetes per service (Intra-class correlation [ICC] = 0.99), as well as the number (ICC = 0.98-0.99) and proportion (ICC = 0.96) of patients with diabetes by gender. The correlation was moderate for the number and proportion of Type 2 diabetes patients per service in the group aged 18-34 years (ICC = 0.65 and 0.8-0.82 respectively). Strong to very strong correlations were found for numbers and proportions of patients being tested for diabetes, and for appropriate monitoring of patients known to have diabetes (ICC = 0.998-1.00). This indicated a generally high degree of concordance between whole-service data extracted by the two Clinical Decision Support Systems. Therefore, the less expensive or less complex option (depending on the individual circumstances of the service) may be appropriate for monitoring diabetes testing and care. However, the extraction of data about subgroups of patients may not be interchangeable.

  13. Child and Informant Influences on Behavioral Ratings of Preschool Children

    ERIC Educational Resources Information Center

    Phillips, Beth M.; Lonigan, Christopher J.

    2010-01-01

    This study investigated relationships among teacher, parent, and observer behavioral ratings of 3- and 4-year-old children using intra-class correlations and analysis of variance. Comparisons within and across children from middle-income (MI; N = 166; mean age = 54.25 months, standard deviation [SD] = 8.74) and low-income (LI; N = 199; mean age =…

  14. Intra-rater and inter-rater reliability of ultrasonographic measurements of acromion-greater tuberosity distance in patients with post-stroke hemiplegia.

    PubMed

    Kumar, Praveen; Cruziah, Reynold; Bradley, Michael; Gray, Selena; Swinkels, Annette

    2016-06-01

    Glenohumeral subluxation (GHS) is reported in up to 81% of patients with stroke. Ultrasonographic measurements of GHS by measuring the acromion-greater tuberosity (AGT) have been found to be reliable for experienced raters. The primary aim was to assess the intra-rater reliability of measurements of AGT distance in people with stroke following a short course of rater training. A secondary aim was to compare the inter-rater reliability of these measurements between novice and experienced raters. Patients with stroke (n = 16; 5 men, 11 women; 74 ± 10 years) with 1-sided weakness who gave informed consent were recruited. Ultrasonographic measurements were recorded at the bedside by two physiotherapists with patients seated upright in a hospital chair. Reliability was assessed by intra-class correlation coefficients (ICCs) and the standard error of measurements (SEM). Minimum detectable change (MDC90) scores were used to estimate the magnitude of change that is likely to exceed measurement error. Mean ± SD AGT distances on the affected and unaffected sides for rater 1 were 2.2 ± 0.7 and 1.7 ± 0.4 cm, respectively. Corresponding values for rater 2 were 2.5 ± 0.6 and 2.0 ± 0.4 cm. Intra-class correlation coefficient values for the affected and unaffected shoulders for rater 1 were 0.96 and 0.91, respectively. Corresponding values for rater 2 were 0.95 and 0.90.SEM and MDC90 for both affected and unaffected shoulders were ≤ 0.2 cm. Inter-rater reliability coefficients were 0.86 (affected) and 0.76 (unaffected) shoulders. Ultrasonographic measurement of AGT distance demonstrates excellent intra-rater reliability for a novice rater. Inter-rater reliability of ultrasonographic measurement of AGT also demonstrates good reliability between novice and experienced raters.

  15. Quantitative comparison and evaluation of software packages for assessment of abdominal adipose tissue distribution by magnetic resonance imaging.

    PubMed

    Bonekamp, S; Ghosh, P; Crawford, S; Solga, S F; Horska, A; Brancati, F L; Diehl, A M; Smith, S; Clark, J M

    2008-01-01

    To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Feature evaluation and test-retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. A random sample of 15 obese adults with type 2 diabetes. Axial T1-weighted spin echo images centered at vertebral bodies of L2-L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test-retest reliability. Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test-retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages.

  16. Quantitative comparison and evaluation of software packages for assessment of abdominal adipose tissue distribution by magnetic resonance imaging

    PubMed Central

    Bonekamp, S; Ghosh, P; Crawford, S; Solga, SF; Horska, A; Brancati, FL; Diehl, AM; Smith, S; Clark, JM

    2009-01-01

    Objective To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Design Feature evaluation and test–retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. Subjects A random sample of 15 obese adults with type 2 diabetes. Measurements Axial T1-weighted spin echo images centered at vertebral bodies of L2–L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test–retest reliability. Results Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test–retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Conclusion Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages. PMID:17700582

  17. Trunk-acceleration based assessment of gait parameters in older persons: a comparison of reliability and validity of four inverted pendulum based estimations.

    PubMed

    Zijlstra, Agnes; Zijlstra, Wiebren

    2013-09-01

    Inverted pendulum (IP) models of human walking allow for wearable motion-sensor based estimations of spatio-temporal gait parameters during unconstrained walking in daily-life conditions. At present it is unclear to what extent different IP based estimations yield different results, and reliability and validity have not been investigated in older persons without a specific medical condition. The aim of this study was to compare reliability and validity of four different IP based estimations of mean step length in independent-living older persons. Participants were assessed twice and walked at different speeds while wearing a tri-axial accelerometer at the lower back. For all step-length estimators, test-retest intra-class correlations approached or were above 0.90. Intra-class correlations with reference step length were above 0.92 with a mean error of 0.0 cm when (1) multiplying the estimated center-of-mass displacement during a step by an individual correction factor in a simple IP model, or (2) adding an individual constant for bipedal stance displacement to the estimated displacement during single stance in a 2-phase IP model. When applying generic corrections or constants in all subjects (i.e. multiplication by 1.25, or adding 75% of foot length), correlations were above 0.75 with a mean error of respectively 2.0 and 1.2 cm. Although the results indicate that an individual adjustment of the IP models provides better estimations of mean step length, the ease of a generic adjustment can be favored when merely evaluating intra-individual differences. Further studies should determine the validity of these IP based estimations for assessing gait in daily life. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Improving Teacher Selection: The Effect of Inter-Rater Reliability in the Screening Process. CEDR Working Paper. WP #2015-7

    ERIC Educational Resources Information Center

    Martinkova, Patricia; Goldhaber, Dan

    2015-01-01

    Inter-rater reliability, commonly assessed by intra-class correlation coefficient ICC, is an important index for describing the extent to which there is consistency amongst two or more raters in assigned measures. In organizational research, the data structure is often hierarchical and designs deviate substantially from the ideal of a balanced…

  19. Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols.

    PubMed

    Forst, Darren; Nijjar, Simrit; Flores-Mir, Carlos; Carey, Jason; Secanell, Marc; Lagravere, Manuel

    2014-12-23

    The objective of this study is to analyze a set of previously developed and proposed image segmentation protocols for precision in both intra- and inter-rater reliability for in vivo tooth volume measurements using cone-beam computed tomography (CBCT) images. Six 3D volume segmentation procedures were proposed and tested for intra- and inter-rater reliability to quantify maxillary first molar volumes. Ten randomly selected maxillary first molars were measured in vivo in random order three times with 10 days separation between measurements. Intra- and inter-rater agreement for all segmentation procedures was attained using intra-class correlation coefficient (ICC). The highest precision was for automated thresholding with manual refinements. A tooth volume measurement protocol for CBCT images employing automated segmentation with manual human refinement on a 2D slice-by-slice basis in all three planes of space possessed excellent intra- and inter-rater reliability. Three-dimensional volume measurements of the entire tooth structure are more precise than 3D volume measurements of only the dental roots apical to the cemento-enamel junction (CEJ).

  20. Inter- and intra-rater reliability and agreement in determining subcutaneous tumour margins in dogs.

    PubMed

    Ranganathan, B; Milovancev, M; Leeper, H; Townsend, K L; Bracha, S; Curran, K

    2018-03-01

    The objective of this prospective study was to evaluate agreement and reliability of calliper-based measurements of locally invasive subcutaneous malignant tumours in dogs. Four raters measured the longest diameter of 12 subcutaneous tumours (7 soft tissue sarcomas and 5 mast cell tumours) from 11 client-owned dogs during 3 randomized, blinded measurement trials, both pre- and post-sedation. Inter- and intra-rater reliability was evaluated using intra-class correlation coefficient (ICC) and agreement was evaluated using Bland-Altman plots. Inter- and intra-rater reliability was good (ICC range of 0.8694-0.89520) and excellent (ICC range of 0.9720-0.9966), respectively. For agreement calculations, an a priori clinically relevant limit of agreement of 10 mm was set. Inter- and intra-rater agreement was unacceptable with inter-rater limits of agreement ranging from 15.9 to 55.6 mm and intra-rater limit of agreement ranging from 11.9 to 28.1 mm. Review of the measurement trial photographs revealed that calliper orientation changes were frequent, occurring in 9/12 (75%) and 8/12 (67%) pre- and post-sedation cases. No significant correlation was found between inter-rater measurement standard deviations and calliper orientation changes or dog body condition score. These findings suggest veterinarians may have poor agreement in determining the gross edge of tumours, which is expected to introduce bias and inconsistency in tumour staging, assessing response to therapy, and surgical margin planning. Due to the potential consequences for veterinary cancer patients, future studies are needed to validate the present findings. © 2018 John Wiley & Sons Ltd.

  1. Evaluating Written Patient Information for Eczema in German: Comparing the Reliability of Two Instruments, DISCERN and EQIP

    PubMed Central

    McCool, Megan E.; Wahl, Josepha; Schlecht, Inga; Apfelbacher, Christian

    2015-01-01

    Patients actively seek information about how to cope with their health problems, but the quality of the information available varies. A number of instruments have been developed to assess the quality of patient information, primarily though in English. Little is known about the reliability of these instruments when applied to patient information in German. The objective of our study was to investigate and compare the reliability of two validated instruments, DISCERN and EQIP, in order to determine which of these instruments is better suited for a further study pertaining to the quality of information available to German patients with eczema. Two independent raters evaluated a random sample of 20 informational brochures in German. All the brochures addressed eczema as a disorder and/or therapy options and care. Intra-rater and inter-rater reliability were assessed by calculating intra-class correlation coefficients, agreement was tested with weighted kappas, and the correlation of the raters’ scores for each instrument was measured with Pearson’s correlation coefficient. DISCERN demonstrated substantial intra- and inter-rater reliability. It also showed slightly better agreement than EQIP. There was a strong correlation of the raters’ scores for both instruments. The findings of this study support the reliability of both DISCERN and EQIP. However, based on the results of the inter-rater reliability, agreement and correlation analyses, we consider DISCERN to be the more precise tool for our project on patient information concerning the treatment and care of eczema. PMID:26440612

  2. Evaluating Written Patient Information for Eczema in German: Comparing the Reliability of Two Instruments, DISCERN and EQIP.

    PubMed

    McCool, Megan E; Wahl, Josepha; Schlecht, Inga; Apfelbacher, Christian

    2015-01-01

    Patients actively seek information about how to cope with their health problems, but the quality of the information available varies. A number of instruments have been developed to assess the quality of patient information, primarily though in English. Little is known about the reliability of these instruments when applied to patient information in German. The objective of our study was to investigate and compare the reliability of two validated instruments, DISCERN and EQIP, in order to determine which of these instruments is better suited for a further study pertaining to the quality of information available to German patients with eczema. Two independent raters evaluated a random sample of 20 informational brochures in German. All the brochures addressed eczema as a disorder and/or therapy options and care. Intra-rater and inter-rater reliability were assessed by calculating intra-class correlation coefficients, agreement was tested with weighted kappas, and the correlation of the raters' scores for each instrument was measured with Pearson's correlation coefficient. DISCERN demonstrated substantial intra- and inter-rater reliability. It also showed slightly better agreement than EQIP. There was a strong correlation of the raters' scores for both instruments. The findings of this study support the reliability of both DISCERN and EQIP. However, based on the results of the inter-rater reliability, agreement and correlation analyses, we consider DISCERN to be the more precise tool for our project on patient information concerning the treatment and care of eczema.

  3. The Scarbase Duo(®): Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool.

    PubMed

    Fell, Matthew; Meirte, Jill; Anthonissen, Mieke; Maertens, Koen; Pleat, Jonathon; Moortgat, Peter

    2016-03-01

    Objective scar assessment tools were designed to help identify problematic scars and direct clinical management. Their use has been restricted by their measurement of a single scar property and the bulky size of equipment. The Scarbase Duo(®) was designed to assess both trans-epidermal water loss (TEWL) and colour of a burn scar whilst being compact and easy to use. Twenty patients with a burn scar were recruited and measurements taken using the Scarbase Duo(®) by two observers. The Scarbase Duo(®) measures TEWL via an open-chamber system and undertakes colorimetry via narrow-band spectrophotometry, producing values for relative erythema and melanin pigmentation. Validity was assessed by comparing the Scarbase Duo(®) against the Dermalab(®) and the Minolta Chromameter(®) respectively for TEWL and colorimetry measurements. The intra-class correlation coefficient (ICC) was used to assess reliability with standard error of measurement (SEM) used to assess reproducibility of measurements. The Pearson correlation coefficient (r) was used to assess the convergent validity. The Scarbase Duo(®) TEWL mode had excellent reliability when used on scars for both intra- (ICC=0.95) and inter-rater (ICC=0.96) measurements with moderate SEM values. The erythema component of the colorimetry mode showed good reliability for use on scars for both intra-(ICC=0.81) and inter-rater (ICC=0.83) measurements with low SEM values. Pigmentation values showed excellent reliability on scar tissue for both intra- (ICC=0.97) and inter-rater (ICC=0.97) with moderate SEM values. The Scarbase Duo(®) TEWL function had excellent correlation with the Dermalab(®) (r=0.93) whilst the colorimetry erythema value had moderate correlation with the Minolta Chromameter (r=0.72). The Scarbase Duo(®) is a reliable and objective scar assessment tool, which is specifically designed for burn scars. However, for clinical use, standardised measurement conditions are recommended. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  4. The reliability of three psoriasis assessment tools: Psoriasis area and severity index, body surface area and physician global assessment.

    PubMed

    Bożek, Agnieszka; Reich, Adam

    2017-08-01

    A wide variety of psoriasis assessment tools have been proposed to evaluate the severity of psoriasis in clinical trials and daily practice. The most frequently used clinical instrument is the psoriasis area and severity index (PASI); however, none of the currently published severity scores used for psoriasis meets all the validation criteria required for an ideal score. The aim of this study was to compare and assess the reliability of 3 commonly used assessment instruments for psoriasis severity: the psoriasis area and severity index (PASI), body surface area (BSA) and physician global assessment (PGA). On the scoring day, 10 trained dermatologists evaluated 9 adult patients with plaque-type psoriasis using the PASI, BSA and PGA. All the subjects were assessed twice by each physician. Correlations between the assessments were analyzed using the Pearson correlation coefficient. Intra-class correlation coefficient (ICC) was calculated to analyze intra-rater reliability, and the coefficient of variation (CV) was used to assess inter-rater variability. Significant correlations were observed among the 3 scales in both assessments. In all 3 scales the ICCs were > 0.75, indicating high intra-rater reliability. The highest ICC was for the BSA (0.96) and the lowest one for the PGA (0.87). The CV for the PGA and PASI were 29.3 and 36.9, respectively, indicating moderate inter-rater variability. The CV for the BSA was 57.1, indicating high inter-rater variability. Comparing the PASI, PGA and BSA, it was shown that the PGA had the highest inter-rater reliability, whereas the BSA had the highest intra-rater reliability. The PASI showed intermediate values in terms of interand intra-rater reliability. None of the 3 assessment instruments showed a significant advantage over the other. A reliable assessment of psoriasis severity requires the use of several independent evaluations simultaneously.

  5. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  6. Correlation and agreement between eplet mismatches calculated using serological, low-intermediate and high resolution molecular human leukocyte antigen typing methods

    PubMed Central

    Fidler, Samantha; D’Orsogna, Lloyd; Irish, Ashley B.; Lewis, Joshua R.; Wong, Germaine; Lim, Wai H.

    2018-01-01

    Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960–0.975) and 0.926 (95% CI 0.899–0.944), respectively; and 0.995 (95% CI 0.994–0.996) and 0.993 (95% CI 0.991–0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation. PMID:29568344

  7. Hierarchical Discriminant Analysis.

    PubMed

    Lu, Di; Ding, Chuntao; Xu, Jinliang; Wang, Shangguang

    2018-01-18

    The Internet of Things (IoT) generates lots of high-dimensional sensor intelligent data. The processing of high-dimensional data (e.g., data visualization and data classification) is very difficult, so it requires excellent subspace learning algorithms to learn a latent subspace to preserve the intrinsic structure of the high-dimensional data, and abandon the least useful information in the subsequent processing. In this context, many subspace learning algorithms have been presented. However, in the process of transforming the high-dimensional data into the low-dimensional space, the huge difference between the sum of inter-class distance and the sum of intra-class distance for distinct data may cause a bias problem. That means that the impact of intra-class distance is overwhelmed. To address this problem, we propose a novel algorithm called Hierarchical Discriminant Analysis (HDA). It minimizes the sum of intra-class distance first, and then maximizes the sum of inter-class distance. This proposed method balances the bias from the inter-class and that from the intra-class to achieve better performance. Extensive experiments are conducted on several benchmark face datasets. The results reveal that HDA obtains better performance than other dimensionality reduction algorithms.

  8. An Evaluation of Mandibular Dental and Basal Arch Dimensions in Class I and Class II Division 1 Adult Syrian Patients using Cone-beam Computed Tomography.

    PubMed

    Al-Hilal, Layal H; Sultan, Kinda; Hajeer, Mohammad Y; Mahmoud, Ghiath; Wanli, Abdulrahman A

    2018-04-01

    Aim: The aim of this study is (1) to inspect any difference in mandibular arch widths between males and females in class I and class II division 1 (class malocclusions using cone-beam computed tomography (CBCT), (2) to compare the mandibular dental and basal widths between the two groups, and (3) to investigate any possible correlation between dental and basal arch widths in both groups. Materials and methods: The CBCT images of 68 patients aged between 18 and 25 years consisted of 34 class I (17 males and 17 females) and 34 class (17 males and 17 females) who were recruited at the Department of Orthodontics, University of Damascus Dental School (Syria). Using on-demand three-dimensional (3D) on axial views, facial axis points for dental measurements and basal bone center (BBC) points for basal measurements were identified on lower canines and first molars. Dental and basal intercanine width (ICW) and intermolar width (IMW) were measured. Results: Independent t-test showed a statistically significant difference between males and females in several variables in both groups and a statistically significant difference between class I and class groups in the basal ICW for both genders and in the dental ICW for females only (p < 0.05). In class I group, Pearson's correlation coefficients between dental and basal measurements showed a strong correlation in the IMW for both genders (r > 0.73; p < 0.01) and a moderate correlation in females' ICW (r = 0.67; p < 0.01). In the class group, a moderate correlation in females' IMW (r = 0.67; p < 0.01) was found. Conclusion: Females compared with males had narrower dimensions. Class I patients had larger ICW than class II-1 patients in all measurements and had narrower IMW than class in most measurements for both genders. There were moderate-to-strong correlations between dental and basal dimensions. BBC points might be landmarks that accurately represent the basal bone arch. Clinical significance: CBCT-based assessments of dental and basal arch dimensions provide a great opportunity to accurately evaluate these aspects, to enhance clinicians' decisions regarding proper tooth movements, and to achieve good dentoalveolar intra-arch harmony. Keywords: Basal arch, Class I, Class Cone-beam computed tomography, Dental arch, Intercanine width, Intermolar width.

  9. Reliability of the Wii Balance Board in kayak.

    PubMed

    Vando, Stefano; Laffaye, Guillaume; Masala, Daniele; Falese, Lavinia; Padulo, Johnny

    2015-01-01

    the seat of the kayaker represent the principal contact point to express mechanical Energy. therefore we investigated the reliability of the Wii Balance Board measures in the kayak vs. on the ground. Bland-Altman test showed a low systematic bias on the ground (2.85%) and in kayak (-2.13%) respectively; while 0.996 for Intra-class correlation coefficient. the Wii Balance Board is useful to assess postural sway in kayak.

  10. A systematic review of statistical methods used to test for reliability of medical instruments measuring continuous variables.

    PubMed

    Zaki, Rafdzah; Bulgiba, Awang; Nordin, Noorhaire; Azina Ismail, Noor

    2013-06-01

    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice. In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. The Intra-class Correlation Coefficient (ICC) is the most popular method with 25 (60%) studies having used this method followed by the comparing means (8 or 19%). Out of 25 studies using the ICC, only 7 (28%) reported the confidence intervals and types of ICC used. Most studies (71%) also tested the agreement of instruments. This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  11. Development and reliability testing of a food store observation form.

    PubMed

    Rimkus, Leah; Powell, Lisa M; Zenk, Shannon N; Han, Euna; Ohri-Vachaspati, Punam; Pugach, Oksana; Barker, Dianne C; Resnick, Elissa A; Quinn, Christopher M; Myllyluoma, Jaana; Chaloupka, Frank J

    2013-01-01

    To develop a reliable food store observational data collection instrument to be used for measuring product availability, pricing, and promotion. Observational data collection. A total of 120 food stores (26 supermarkets, 34 grocery stores, 54 gas/convenience stores, and 6 mass merchandise stores) in the Chicago metropolitan statistical area. Inter-rater reliability for product availability, pricing, and promotion measures on a food store observational data collection instrument. Cohen's kappa coefficient and proportion of overall agreement for dichotomous variables and intra-class correlation coefficient for continuous variables. Inter-rater reliability, as measured by average kappa coefficient, was 0.84 for food and beverage product availability measures, 0.80 for interior store characteristics, and 0.70 for exterior store characteristics. For continuous measures, average intra-class correlation coefficient was 0.82 for product pricing measures; 0.90 for counts of fresh, frozen, and canned fruit and vegetable options; and 0.85 for counts of advertisements on the store exterior and property. The vast majority of measures demonstrated substantial or almost perfect agreement. Although some items may require revision, results suggest that the instrument may be used to reliably measure the food store environment. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  12. Intra-class correlation estimates for assessment of vitamin A intake in children.

    PubMed

    Agarwal, Girdhar G; Awasthi, Shally; Walter, Stephen D

    2005-03-01

    In many community-based surveys, multi-level sampling is inherent in the design. In the design of these studies, especially to calculate the appropriate sample size, investigators need good estimates of intra-class correlation coefficient (ICC), along with the cluster size, to adjust for variation inflation due to clustering at each level. The present study used data on the assessment of clinical vitamin A deficiency and intake of vitamin A-rich food in children in a district in India. For the survey, 16 households were sampled from 200 villages nested within eight randomly-selected blocks of the district. ICCs and components of variances were estimated from a three-level hierarchical random effects analysis of variance model. Estimates of ICCs and variance components were obtained at village and block levels. Between-cluster variation was evident at each level of clustering. In these estimates, ICCs were inversely related to cluster size, but the design effect could be substantial for large clusters. At the block level, most ICC estimates were below 0.07. At the village level, many ICC estimates ranged from 0.014 to 0.45. These estimates may provide useful information for the design of epidemiological studies in which the sampled (or allocated) units range in size from households to large administrative zones.

  13. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    PubMed

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Bimanual Capacity of Children With Cerebral Palsy: Intra- and Interrater Reliability of a Revised Edition of the Bimanual Fine Motor Function Classification.

    PubMed

    Elvrum, Ann-Kristin G; Beckung, Eva; Sæther, Rannei; Lydersen, Stian; Vik, Torstein; Himmelmann, Kate

    2017-08-01

    To develop a revised edition of the Bimanual Fine Motor Function (BFMF 2), as a classification of fine motor capacity in children with cerebral palsy (CP), and establish intra- and interrater reliability of this edition. The content of the original BFMF was discussed by an expert panel, resulting in a revised edition comprising the original description of the classification levels, but in addition including figures with specific explanatory text. Four professionals classified fine motor function of 79 children (3-17 years; 45 boys) who represented all subtypes of CP and Manual Ability Classification levels (I-V). Intra- and inter-rater reliability was assessed using overall intra-class correlation coefficient (ICC), and Cohen's quadratic weighted kappa. The overall ICC was 0.86. Cohen's weighted kappa indicated high intra-rater (к w : >0.90) and inter-rater (к w : >0.85) reliability. The revised BFMF 2 had high intra- and interrater reliability. The classification levels could be determined from short video recordings (<5 minutes), using the figures and precise descriptions of the fine motor function levels included in the BFMF 2. Thus, the BFMF 2 may be a feasible and useful classification of fine motor capacity both in research and in clinical practice.

  15. Dynamic gadolinium-enhanced magnetic resonance imaging allows accurate assessment of the synovial inflammatory activity in rheumatoid arthritis knee joints: a comparison with synovial histology.

    PubMed

    Axelsen, M B; Stoltenberg, M; Poggenborg, R P; Kubassova, O; Boesen, M; Bliddal, H; Hørslev-Petersen, K; Hanson, L G; Østergaard, M

    2012-03-01

    To determine whether dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) evaluated using semi-automatic image processing software can accurately assess synovial inflammation in rheumatoid arthritis (RA) knee joints. In 17 RA patients undergoing knee surgery, the average grade of histological synovial inflammation was determined from four biopsies obtained during surgery. A preoperative series of T(1)-weighted dynamic fast low-angle shot (FLASH) MR images was obtained. Parameters characterizing contrast uptake dynamics, including the initial rate of enhancement (IRE), were generated by the software in three different areas: (I) the entire slice (Whole slice); (II) a manually outlined region of interest (ROI) drawn quickly around the joint, omitting large artefacts such as blood vessels (Quick ROI); and (III) a manually outlined ROI following the synovial capsule of the knee joint (Precise ROI). Intra- and inter-reader agreement was assessed using the intra-class correlation coefficient (ICC). The IRE from the Quick ROI and the Precise ROI revealed high correlations to the grade of histological inflammation (Spearman's correlation coefficient (rho) = 0.70, p = 0.001 and rho = 0.74, p = 0.001, respectively). Intra- and inter-reader ICCs were very high (0.93-1.00). No Whole slice parameters were correlated to histology. DCE-MRI provides fast and accurate assessment of synovial inflammation in RA patients. Manual outlining of the joint to omit large artefacts is necessary.

  16. Predictors and long-term reproducibility of urinary phthalate metabolites in middle-aged men and women living in urban Shanghai

    PubMed Central

    Starling, Anne P.; Engel, Lawrence S.; Calafat, Antonia M.; Koutros, Stella; Satagopan, Jaya M.; Yang, Gong; Matthews, Charles E.; Cai, Qiuyin; Buckley, Jessie P.; Ji, Bu-Tian; Cai, Hui; Chow, Wong-Ho; Zheng, Wei; Gao, Yu-Tang; Rothman, Nathaniel; Xiang, Yong-Bing; Shu, Xiao-Ou

    2015-01-01

    Phthalate esters are man-made chemicals commonly used as plasticizers and solvents, and humans may be exposed through ingestion, inhalation, and dermal absorption. Little is known about predictors of phthalate exposure, particularly in Asian countries. Because phthalates are rapidly metabolized and excreted from the body following exposure, it is important to evaluate whether phthalate metabolites measured at a single point in time can reliably rank exposures to phthalates over a period of time. We examined the concentrations and predictors of phthalate metabolite concentrations among 50 middle-aged women and 50 men from two Shanghai cohorts, enrolled in 1997-2000 and 2002-2006, respectively. We assessed the reproducibility of urinary concentrations of phthalate metabolites in three spot samples per participant taken several years apart (mean interval between first and third sample was 7.5 years [women] or 2.9 years [men]), using Spearman's rank correlation coefficients and intra-class correlation coefficients. We detected ten phthalate metabolites in at least 50% of individuals for two or more samples. Participant sex, age, menopausal status, education, income, body mass index, consumption of bottled water, recent intake of medication, and time of day of collection of the urine sample were associated with concentrations of certain phthalate metabolites. The reproducibility of an individual's urinary concentration of phthalate metabolites across several years was low, with all intra-class correlation coefficients and most Spearman rank correlation coefficients ≤ 0.3. Only mono(2-ethylhexyl) phthalate, a metabolite of di(2-ethylhexyl)phthalate, had a Spearman rank correlation coefficient ≥ 0.4 among men, suggesting moderate reproducibility. These findings suggest that a single spot urine sample is not sufficient to rank exposures to phthalates over several years in an adult urban Chinese population. PMID:26255822

  17. Improved estimation of subject-level functional connectivity using full and partial correlation with empirical Bayes shrinkage.

    PubMed

    Mejia, Amanda F; Nebel, Mary Beth; Barber, Anita D; Choe, Ann S; Pekar, James J; Caffo, Brian S; Lindquist, Martin A

    2018-05-15

    Reliability of subject-level resting-state functional connectivity (FC) is determined in part by the statistical techniques employed in its estimation. Methods that pool information across subjects to inform estimation of subject-level effects (e.g., Bayesian approaches) have been shown to enhance reliability of subject-level FC. However, fully Bayesian approaches are computationally demanding, while empirical Bayesian approaches typically rely on using repeated measures to estimate the variance components in the model. Here, we avoid the need for repeated measures by proposing a novel measurement error model for FC describing the different sources of variance and error, which we use to perform empirical Bayes shrinkage of subject-level FC towards the group average. In addition, since the traditional intra-class correlation coefficient (ICC) is inappropriate for biased estimates, we propose a new reliability measure denoted the mean squared error intra-class correlation coefficient (ICC MSE ) to properly assess the reliability of the resulting (biased) estimates. We apply the proposed techniques to test-retest resting-state fMRI data on 461 subjects from the Human Connectome Project to estimate connectivity between 100 regions identified through independent components analysis (ICA). We consider both correlation and partial correlation as the measure of FC and assess the benefit of shrinkage for each measure, as well as the effects of scan duration. We find that shrinkage estimates of subject-level FC exhibit substantially greater reliability than traditional estimates across various scan durations, even for the most reliable connections and regardless of connectivity measure. Additionally, we find partial correlation reliability to be highly sensitive to the choice of penalty term, and to be generally worse than that of full correlations except for certain connections and a narrow range of penalty values. This suggests that the penalty needs to be chosen carefully when using partial correlations. Copyright © 2018. Published by Elsevier Inc.

  18. The reliability of four widely used patellar height ratios.

    PubMed

    van Duijvenbode, Dennis; Stavenuiter, Michel; Burger, Bart; van Dijke, Cees; Spermon, Jacco; Hoozemans, Marco

    2016-03-01

    The objective of this study was to evaluate the inter-observer reliability and the intra-observer reliability of four patellar height ratios: Insall-Salvati (IS), modified Insall-Salvati (MIS), Blackburne-Peel (BP) and Caton-Deschamps (CD). The patellar height ratios were assessed by four independent examiners using weight-bearing lateral knee radiographs in 30° flexion. Intra-class correlation coefficients and Fleiss' kappa's were determined. The inter-observer reliability was excellent for the IS and moderate for the other ratios. When the ratio values were categorized, the inter-observer reliability was strong for the IS, moderate for the MIS and BP, and poor for the CD. The intra-observer reliability was excellent for the IS, MIS and CD, and strong for the BP. When the ratio values were categorized, the intra-observer reliability was strong for the IS and MIS, and moderate for the other ratios. Although the IS showed best reliability, we advise to use the MIS as it showed the second best reliability but is, according to the literature, associated with better validity.

  19. Rater reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS).

    PubMed

    Baker, Nancy A; Cook, James R; Redfern, Mark S

    2009-01-01

    This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.

  20. Simplified Chinese version of the Forgotten Joint Score (FJS) for patients who underwent joint arthroplasty: cross-cultural adaptation and validation.

    PubMed

    Cao, Shiqi; Liu, Ning; Han, Wuxiang; Zi, Yunpeng; Peng, Fan; Li, Lexiang; Fu, Qiwei; Chen, Yi; Zheng, Weijie; Qian, Qirong

    2017-01-14

    The Forgotten Joint Score (FJS) is a newly developed health-related quality of life (HRQoL) questionnaire designed to evaluate the awareness after total knee arthroplasty (TKA). This study cross-culturally adapted and psychometrically validated a simplified Chinese version of the FJS (SC-FJS). Cross-cultural adaptation was performed according to the internationally recognized guidelines. One-hundred and fifty participants who underwent primary TKA were recruited in this study. Cronbach's α and intra-class correlations were used to determine reliability. Construct validity was analyzed by evaluating the correlations between SC-FJS and the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the short form (36) health survey (SF-36). Each of the 12 items was properly responded and correlated with the total items. SC-FJS had excellent reliability [Cronbach's α = 0.907, intra-class correlation coefficient (ICC) = 0.970, 95% CI 0.959-0.978). Elimination of any one item in all did not result in a value of Cronbach's α of <0.80. SC-FJS had a high correlation with symptoms (0.67, p < 0.001) and pain (0.60, p < 0.001) domains of KOOS and social functioning (0.66, p < 0.001) domain of SF-36, and it also moderately correlated with function in daily living (0.53, p < 0.001) and function in sport and recreation (0.40, p < 0.001) domains of KOOS, and physical subscale of SF-36 (0.49-0.53, p < 0.001) but had a low (r = 0.20) or not significant (p > 0.05) correlation with mental subscale of SF-36. SC-FJS demonstrated excellent acceptability, internal consistency, reliability, and construct validity, which can be recommended for patients who underwent joint arthroplasty in Mainland China.

  1. Quantitative assessment of muscle in dogs using a vertebral epaxial muscle score.

    PubMed

    Freeman, Lisa M; Sutherland-Smith, James; Prantil, Lori R; Sato, Amy F; Rush, John E; Barton, Bruce A

    2017-10-01

    Muscle loss associated with disease (cachexia) or with aging (sarcopenia) is common in dogs, but clinically relevant methods for quantifying muscle loss are needed. We previously validated an ultrasound method of quantifying muscle size in dogs in a single breed. The goal of this study was to assess the variability and reproducibility of the Vertebral Epaxial Muscle Score (VEMS) in other dog breeds. Static ultrasound images were obtained from 38 healthy, neutered dogs of 5 different breeds between 1- and 5-years-old. The maximal transverse right epaxial muscle height and area at the level of the 13th thoracic vertebra (T13) were measured. Length of the 4th thoracic vertebra (T4) was measured from thoracic radiography. Ratios of the muscle height and area to vertebral length (height/T4 and area/T4, respectively) were calculated to account for differences in body size among breeds. Reproducibility testing was performed on 2 dogs of each breed (26% of the total) to determine intra- and inter-investigator reproducibility, as well as intra-class correlation. Mean height/T4 = 1.02 ± 0.18 and mean area/T4 = 3.32 ± 1.68. There was no significant difference for height/T4 ( P = 0.10) among breeds, but breeds were significantly different in area/T4 ( P < 0.001). Intra-class correlation ranged from 0.80 to 0.99. Testing showed better reproducibility for height/T4 compared to area/T4. The VEMS using height/T4 was valid and reproducible for healthy dogs of different sizes and body conformations. Studies assessing this technique in dogs with congestive heart failure and other diseases associated with muscle loss are warranted.

  2. Quantitative assessment of muscle in dogs using a vertebral epaxial muscle score

    PubMed Central

    Freeman, Lisa M.; Sutherland-Smith, James; Prantil, Lori R.; Sato, Amy F.; Rush, John E.; Barton, Bruce A.

    2017-01-01

    Muscle loss associated with disease (cachexia) or with aging (sarcopenia) is common in dogs, but clinically relevant methods for quantifying muscle loss are needed. We previously validated an ultrasound method of quantifying muscle size in dogs in a single breed. The goal of this study was to assess the variability and reproducibility of the Vertebral Epaxial Muscle Score (VEMS) in other dog breeds. Static ultrasound images were obtained from 38 healthy, neutered dogs of 5 different breeds between 1- and 5-years-old. The maximal transverse right epaxial muscle height and area at the level of the 13th thoracic vertebra (T13) were measured. Length of the 4th thoracic vertebra (T4) was measured from thoracic radiography. Ratios of the muscle height and area to vertebral length (height/T4 and area/T4, respectively) were calculated to account for differences in body size among breeds. Reproducibility testing was performed on 2 dogs of each breed (26% of the total) to determine intra- and inter-investigator reproducibility, as well as intra-class correlation. Mean height/T4 = 1.02 ± 0.18 and mean area/T4 = 3.32 ± 1.68. There was no significant difference for height/T4 (P = 0.10) among breeds, but breeds were significantly different in area/T4 (P < 0.001). Intra-class correlation ranged from 0.80 to 0.99. Testing showed better reproducibility for height/T4 compared to area/T4. The VEMS using height/T4 was valid and reproducible for healthy dogs of different sizes and body conformations. Studies assessing this technique in dogs with congestive heart failure and other diseases associated with muscle loss are warranted. PMID:29081582

  3. Quality of Radiomic Features in Glioblastoma Multiforme: Impact of Semi-Automated Tumor Segmentation Software

    PubMed Central

    Lee, Myungeun; Woo, Boyeong; Kuo, Michael D.; Jamshidi, Neema

    2017-01-01

    Objective The purpose of this study was to evaluate the reliability and quality of radiomic features in glioblastoma multiforme (GBM) derived from tumor volumes obtained with semi-automated tumor segmentation software. Materials and Methods MR images of 45 GBM patients (29 males, 16 females) were downloaded from The Cancer Imaging Archive, in which post-contrast T1-weighted imaging and fluid-attenuated inversion recovery MR sequences were used. Two raters independently segmented the tumors using two semi-automated segmentation tools (TumorPrism3D and 3D Slicer). Regions of interest corresponding to contrast-enhancing lesion, necrotic portions, and non-enhancing T2 high signal intensity component were segmented for each tumor. A total of 180 imaging features were extracted, and their quality was evaluated in terms of stability, normalized dynamic range (NDR), and redundancy, using intra-class correlation coefficients, cluster consensus, and Rand Statistic. Results Our study results showed that most of the radiomic features in GBM were highly stable. Over 90% of 180 features showed good stability (intra-class correlation coefficient [ICC] ≥ 0.8), whereas only 7 features were of poor stability (ICC < 0.5). Most first order statistics and morphometric features showed moderate-to-high NDR (4 > NDR ≥1), while above 35% of the texture features showed poor NDR (< 1). Features were shown to cluster into only 5 groups, indicating that they were highly redundant. Conclusion The use of semi-automated software tools provided sufficiently reliable tumor segmentation and feature stability; thus helping to overcome the inherent inter-rater and intra-rater variability of user intervention. However, certain aspects of feature quality, including NDR and redundancy, need to be assessed for determination of representative signature features before further development of radiomics. PMID:28458602

  4. Quality of Radiomic Features in Glioblastoma Multiforme: Impact of Semi-Automated Tumor Segmentation Software.

    PubMed

    Lee, Myungeun; Woo, Boyeong; Kuo, Michael D; Jamshidi, Neema; Kim, Jong Hyo

    2017-01-01

    The purpose of this study was to evaluate the reliability and quality of radiomic features in glioblastoma multiforme (GBM) derived from tumor volumes obtained with semi-automated tumor segmentation software. MR images of 45 GBM patients (29 males, 16 females) were downloaded from The Cancer Imaging Archive, in which post-contrast T1-weighted imaging and fluid-attenuated inversion recovery MR sequences were used. Two raters independently segmented the tumors using two semi-automated segmentation tools (TumorPrism3D and 3D Slicer). Regions of interest corresponding to contrast-enhancing lesion, necrotic portions, and non-enhancing T2 high signal intensity component were segmented for each tumor. A total of 180 imaging features were extracted, and their quality was evaluated in terms of stability, normalized dynamic range (NDR), and redundancy, using intra-class correlation coefficients, cluster consensus, and Rand Statistic. Our study results showed that most of the radiomic features in GBM were highly stable. Over 90% of 180 features showed good stability (intra-class correlation coefficient [ICC] ≥ 0.8), whereas only 7 features were of poor stability (ICC < 0.5). Most first order statistics and morphometric features showed moderate-to-high NDR (4 > NDR ≥1), while above 35% of the texture features showed poor NDR (< 1). Features were shown to cluster into only 5 groups, indicating that they were highly redundant. The use of semi-automated software tools provided sufficiently reliable tumor segmentation and feature stability; thus helping to overcome the inherent inter-rater and intra-rater variability of user intervention. However, certain aspects of feature quality, including NDR and redundancy, need to be assessed for determination of representative signature features before further development of radiomics.

  5. Reliability of laser Doppler flowmetry curve reading for measurement of toe and ankle pressures: intra- and inter-observer variation.

    PubMed

    Høyer, C; Paludan, J P D; Pavar, S; Biurrun Manresa, J A; Petersen, L J

    2014-03-01

    To assess the intra- and inter-observer variation in laser Doppler flowmetry curve reading for measurement of toe and ankle pressures. A prospective single blinded diagnostic accuracy study was conducted on 200 patients with known or suspected peripheral arterial disease (PAD), with a total of 760 curve sets produced. The first curve reading for this study was performed by laboratory technologists blinded to clinical clues and previous readings at least 3 months after the primary data sampling. The pressure curves were later reassessed following another period of at least 3 months. Observer agreement in diagnostic classification according to TASC-II criteria was quantified using Cohen's kappa. Reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. The overall agreement in diagnostic classification (PAD/not PAD) was 173/200 (87%) for intra-observer (κ = .858) and 175/200 (88%) for inter-observer data (κ = .787). Reliability analysis confirmed excellent correlation for both intra- and inter-observer data (ICC all ≥.931). The coefficients of variance ranged from 2.27% to 6.44% for intra-observer and 2.39% to 8.42% for inter-observer data. Subgroup analysis showed lower observer-variation for reading of toe pressures in patients with diabetes and/or chronic kidney disease than patients not diagnosed with these conditions. Bland-Altman plots showed higher variation in toe pressure readings than ankle pressure readings. This study shows substantial intra- and inter-observer agreement in diagnostic classification and reading of absolute pressures when using laboratory technologists as observers. The study emphasises that observer variation for curve reading is an important factor concerning the overall reproducibility of the method. Our data suggest diabetes and chronic kidney disease have an influence on toe pressure reproducibility. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Reliability of mercury-in-silastic strain gauge plethysmography curve reading: influence of clinical clues and observer variation.

    PubMed

    Høyer, Christian; Pavar, Susanne; Pedersen, Begitte H; Biurrun Manresa, José A; Petersen, Lars J

    2013-08-01

    Mercury-in-silastic strain gauge pletysmography (SGP) is a well-established technique for blood flow and blood pressure measurements. The aim of this study was to examine (i) the possible influence of clinical clues, e.g. the presence of wounds and color changes during blood pressure measurements, and (ii) intra- and inter-observer variation of curve interpretation for segmental blood pressure measurements. A total of 204 patients with known or suspected peripheral arterial disease (PAD) were included in a diagnostic accuracy trial. Toe and ankle pressures were measured in both limbs, and primary observers analyzed a total of 804 pressure curve sets. The SGP curves were later reanalyzed separately by two observers blinded to clinical clues. Intra- and inter-observer agreement was quantified using Cohen's kappa and reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. There was an overall agreement regarding patient diagnostic classification (PAD/not PAD) in 202/204 (99.0%) for intra-observer (κ = 0.969, p < 0.001), and 201/204 (98.5%) for inter-observer readings (κ = 0.953, p < 0.001). Reliability analysis showed excellent correlation between blinded versus non-blinded and inter-observer readings for determination of absolute segmental pressures (all intraclass correlation coefficients ≥ 0.984). The coefficient of variance for determination of absolute segmental blood pressure ranged from 2.9-3.4% for blinded/non-blinded data and from 3.8-5.0% for inter-observer data. This study shows a low inter-observer variation among experienced laboratory technicians for reading strain gauge curves. The low variation between blinded/non-blinded readings indicates that SGP measurements are minimally biased by clinical clues.

  7. Economic Restructuring and Intra-Generational Class Mobility in Mexico

    ERIC Educational Resources Information Center

    Parrado, Emilio A.

    2005-01-01

    This paper compares men's career opportunities and intra-generational class mobility across periods with markedly different development strategies in Mexico. Despite its significance for social stratification and inequality in Mexico, research on mobility has been relatively scant in recent decades. Using data from the National Retrospective…

  8. Reliability and Validity of a New Test of Agility and Skill for Female Amateur Soccer Players

    PubMed Central

    Kutlu, Mehmet; Yapici, Hakan; Yilmaz, Abdullah

    2017-01-01

    Abstract The aim of this study was to evaluate the Agility and Skill Test, which had been recently developed to assess agility and skill in female athletes. Following a 10 min warm-up, two trials to test the reliability and validity of the test were conducted one week apart. Measurements were collected to compare soccer players’ physical performance in a 20 m sprint, a T-Drill test, the Illinois Agility Run Test, change-of-direction and acceleration, as well as agility and skill. All tests were completed following the same order. Thirty-four amateur female soccer players were recruited (age = 20.8 ± 1.9 years; body height = 166 ± 6.9 cm; body mass = 55.5 ± 5.8 kg). To determine the reliability and usefulness of these tests, paired sample t-tests, intra-class correlation coefficients, typical error, coefficient of variation, and differences between the typical error and smallest worthwhile change statistics were computed. Test results showed no significant differences between the two sessions (p > 0.01). There were higher intra-class correlations between the test and retest values (r = 0.94–0.99) for all tests. Typical error values were below the smallest worthwhile change, indicating ‘good’ usefulness for these tests. A near perfect Pearson correlation between the Agility and Skill Test (r = 0.98) was found, and there were moderate-to-large levels of correlation between the Agility and Skill Test and other measures (r = 0.37 to r = 0.56). The results of this study suggest that the Agility and Skill Test is a reliable and valid test for female soccer players and has significant value for assessing the integrative agility and skill capability of soccer players. PMID:28469760

  9. Cross-Cultural and Psychometric Properties Assessment of the Exercise Self-Efficacy Scale in Individuals with Spinal Cord Injury.

    PubMed

    Pisconti, Fernando; Mahmoud Smaili Santos, Suhaila; Lopes, Josiane; Rosa Cardoso, Jefferson; Lopes Lavado, Edson

    2017-11-29

    The Exercise Self-Efficacy scale (ESES) is a reliable measure, in the English language, of exercise self-efficacy in individuals with spinal cord injury. The aim of this study was to culturally adjust and validate the Exercise Self-Efficacy scale in the Portuguese language. The Exercise Self-Efficacy scale was applied to 76 subjects, with three-month intervals (three applications in total). The reliability was appraised using the intra-class correlation coefficient and Bland-Altman methods, and the internal consistency was evaluated using Cronbach´s alpha. The Exercise Self-Efficacy scale was correlated with the domains of the Quality of life Questionnaire SF-36 and Functional Independence Measure and tested using the Spearman rho coefficient. The Exercise Self-Efficacy scale-Brazil presented good internal consistency (alpha 1 = 0.856; alpha 2 = 0.855; alpha 3 = 0.822) and high reliability in the test-retest (intra-class correlation coefficient = 0.97). There was a strong correlation between the Exercise Self-Efficacy scale-Brazil and the SF-36 only in the functional capacity domain (rho = 0.708). There were no changes in Exercise Self-Efficacy scale-Brazil scores between the three applications (p = 0.796). The validation of the Exercise Self-Efficacy scale questionnaire permits the assessor to use it reliably in Portuguese speaking countries, since it is the first instrument measuring self-efficacy specifically during exercises in individuals with spinal cord injury. Furthermore, the questionnaire can be used as an instrument to verify the effectiveness of interventions that use exercise as an outcome. The results of the Brazilian version of the Exercise Self-Efficacy scale support its use as a reliable and valid measurement of exercise self-efficacy for this population.

  10. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    PubMed

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  11. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    PubMed

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  12. Observed intra-cluster correlation coefficients in a cluster survey sample of patient encounters in general practice in Australia

    PubMed Central

    Knox, Stephanie A; Chondros, Patty

    2004-01-01

    Background Cluster sample study designs are cost effective, however cluster samples violate the simple random sample assumption of independence of observations. Failure to account for the intra-cluster correlation of observations when sampling through clusters may lead to an under-powered study. Researchers therefore need estimates of intra-cluster correlation for a range of outcomes to calculate sample size. We report intra-cluster correlation coefficients observed within a large-scale cross-sectional study of general practice in Australia, where the general practitioner (GP) was the primary sampling unit and the patient encounter was the unit of inference. Methods Each year the Bettering the Evaluation and Care of Health (BEACH) study recruits a random sample of approximately 1,000 GPs across Australia. Each GP completes details of 100 consecutive patient encounters. Intra-cluster correlation coefficients were estimated for patient demographics, morbidity managed and treatments received. Intra-cluster correlation coefficients were estimated for descriptive outcomes and for associations between outcomes and predictors and were compared across two independent samples of GPs drawn three years apart. Results Between April 1999 and March 2000, a random sample of 1,047 Australian general practitioners recorded details of 104,700 patient encounters. Intra-cluster correlation coefficients for patient demographics ranged from 0.055 for patient sex to 0.451 for language spoken at home. Intra-cluster correlations for morbidity variables ranged from 0.005 for the management of eye problems to 0.059 for management of psychological problems. Intra-cluster correlation for the association between two variables was smaller than the descriptive intra-cluster correlation of each variable. When compared with the April 2002 to March 2003 sample (1,008 GPs) the estimated intra-cluster correlation coefficients were found to be consistent across samples. Conclusions The demonstrated precision and reliability of the estimated intra-cluster correlations indicate that these coefficients will be useful for calculating sample sizes in future general practice surveys that use the GP as the primary sampling unit. PMID:15613248

  13. Reliability of the Wii Balance Board in kayak

    PubMed Central

    Vando, Stefano; Laffaye, Guillaume; Masala, Daniele; Falese, Lavinia; Padulo, Johnny

    2015-01-01

    Summary Background: the seat of the kayaker represent the principal contact point to express mechanical Energy. Methods: therefore we investigated the reliability of the Wii Balance Board measures in the kayak vs. on the ground. Results: Bland-Altman test showed a low systematic bias on the ground (2.85%) and in kayak (−2.13%) respectively; while 0.996 for Intra-class correlation coefficient. Conclusion: the Wii Balance Board is useful to assess postural sway in kayak. PMID:25878987

  14. The coefficient of determination R2 and intra-class correlation coefficient from generalized linear mixed-effects models revisited and expanded.

    PubMed

    Nakagawa, Shinichi; Johnson, Paul C D; Schielzeth, Holger

    2017-09-01

    The coefficient of determination R 2 quantifies the proportion of variance explained by a statistical model and is an important summary statistic of biological interest. However, estimating R 2 for generalized linear mixed models (GLMMs) remains challenging. We have previously introduced a version of R 2 that we called [Formula: see text] for Poisson and binomial GLMMs, but not for other distributional families. Similarly, we earlier discussed how to estimate intra-class correlation coefficients (ICCs) using Poisson and binomial GLMMs. In this paper, we generalize our methods to all other non-Gaussian distributions, in particular to negative binomial and gamma distributions that are commonly used for modelling biological data. While expanding our approach, we highlight two useful concepts for biologists, Jensen's inequality and the delta method, both of which help us in understanding the properties of GLMMs. Jensen's inequality has important implications for biologically meaningful interpretation of GLMMs, whereas the delta method allows a general derivation of variance associated with non-Gaussian distributions. We also discuss some special considerations for binomial GLMMs with binary or proportion data. We illustrate the implementation of our extension by worked examples from the field of ecology and evolution in the R environment. However, our method can be used across disciplines and regardless of statistical environments. © 2017 The Author(s).

  15. Towards an Operational Definition of Clinical Competency in Pharmacy

    PubMed Central

    2015-01-01

    Objective. To estimate the inter-rater reliability and accuracy of ratings of competence in student pharmacist/patient clinical interactions as depicted in videotaped simulations and to compare expert panelist and typical preceptor ratings of those interactions. Methods. This study used a multifactorial experimental design to estimate inter-rater reliability and accuracy of preceptors’ assessment of student performance in clinical simulations. The study protocol used nine 5-10 minute video vignettes portraying different levels of competency in student performance in simulated clinical interactions. Intra-Class Correlation (ICC) was used to calculate inter-rater reliability and Fisher exact test was used to compare differences in distribution of scores between expert and nonexpert assessments. Results. Preceptors (n=42) across 5 states assessed the simulated performances. Intra-Class Correlation estimates were higher for 3 nonrandomized video simulations compared to the 6 randomized simulations. Preceptors more readily identified high and low student performances compared to satisfactory performances. In nearly two-thirds of the rating opportunities, a higher proportion of expert panelists than preceptors rated the student performance correctly (18 of 27 scenarios). Conclusion. Valid and reliable assessments are critically important because they affect student grades and formative student feedback. Study results indicate the need for pharmacy preceptor training in performance assessment. The process demonstrated in this study can be used to establish minimum preceptor benchmarks for future national training programs. PMID:26089563

  16. Effects of atmospheric stability and urban morphology on daytime intra-urban temperature variability for Glasgow, UK.

    PubMed

    Drach, Patricia; Krüger, Eduardo L; Emmanuel, Rohinton

    2018-06-15

    This study investigates the joint effect of atmospheric conditions and urban morphology, expressed as the Sky View Factor (SVF), on intra-urban variability. The study has been carried out in Glasgow, UK, a shrinking city with a maritime temperate climate type, and findings could guide future climate adaptation plans in terms of morphology and services provided by the municipality to overcome thermal discomfort in outdoor settings. In this case, SVF has been used as an indicator of urban morphology. The modified Pasquill-Gifford-Turner (PGT) classification system was adopted for classifying the temperature monitoring periods according to atmospheric stability conditions. Thirty two locations were selected on the basis of SVF with a wide variety of urban shapes (narrow streets, neighbourhood green spaces, urban parks, street canyons and public squares) and compared to a reference weather station during a total of twenty three transects during late spring and summer in 2013. Maximum daytime intra-urban temperature differences were found to be strongly correlated with atmospheric stability classes. Furthermore, differences in air temperature are noticeable in urban canyons, with a direct correlation to the site's SVF (or sky openness) and with an inverse trend under open-air conditions. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. The reliability and validity of measurements of human dental casts made by an intra-oral 3D scanner, with conventional hand-held digital callipers as the comparison measure.

    PubMed

    Rajshekar, Mithun; Julian, Roberta; Williams, Anne-Marie; Tennant, Marc; Forrest, Alex; Walsh, Laurence J; Wilson, Gary; Blizzard, Leigh

    2017-09-01

    Intra-oral 3D scanning of dentitions has the potential to provide a fast, accurate and non-invasive method of recording dental information. The aim of this study was to assess the reliability of measurements of human dental casts made using a portable intra-oral 3D scanner appropriate for field use. Two examiners each measured 84 tooth and 26 arch features of 50 sets of upper and lower human dental casts using digital hand-held callipers, and secondly using the measuring tool provided with the Zfx IntraScan intraoral 3D scanner applied to the virtual dental casts. The measurements were repeated at least one week later. Reliability and validity were quantified concurrently by calculation of intra-class correlation coefficients (ICC) and standard errors of measurement (SEM). The measurements of the 110 landmark features of human dental casts made using the intra-oral 3D scanner were virtually indistinguishable from measurements of the same features made using conventional hand-held callipers. The difference of means as a percentage of the average of the measurements by each method ranged between 0.030% and 1.134%. The intermethod SEMs ranged between 0.037% and 0.535%, and the inter-method ICCs ranged between 0.904 and 0.999, for both the upper and the lower arches. The inter-rater SEMs were one-half and the intra-method/rater SEMs were one-third of the inter-method values. This study demonstrates that the Zfx IntraScan intra-oral 3D scanner with its virtual on-screen measuring tool is a reliable and valid method for measuring the key features of dental casts. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Inter-Rater Reliability and Intra-Rater Reliability of Assessing the 2-Minute Push-Up Test.

    PubMed

    Fielitz, Lynn; Coelho, Jeffrey; Horne, Thomas; Brechue, William

    2016-02-01

    The purpose of this study was to assess inter-rater reliability and intra-rater reliability of the 2-minute, 90° push-up test as utilized in the Army Physical Fitness Test. Analysis of rater assessment reliability included both total score agreement and agreement across individual push-up repetitions. This study utilized 8 Raters who assessed 15 different videotaped push-up performances over 4 iterations separated by a minimum of 1 week. The 15 push-up participants were videotaped during the semiannual Army Physical Fitness Test. Each Rater randomly viewed the 15 push-up and verbally responded with a "yes" or "no" to each push-up repetition. The data generated were analyzed using the Pearson product-moment correlation as well as the kappa, modified kappa and the intra-class correlation coefficient (3,1). An attribute agreement analysis was conducted to determine the percent of inter-rater and intra-rater agreement across individual push-ups.The results indicated that Raters varied a great deal in assessing push-ups. Over the 4 trials of 15 participants, the overall scores of the Raters varied between 3.0 and 35.7 push-ups. Post hoc comparisons found that there was significant increase in the grand mean of push-ups from trials 1-3 to trial 4 (p < 0.05). Also, there was a significant difference among raters over the 4 trials (p < 0.05). Pearson correlation coefficients for inter-rater and intra-rater reliability identified inter-rater reliability coefficients were between 0.10 and 0.97. Intra-rater coefficients were between 0.48 and 0.99. Intra-rater agreement for individual push-up repetitions ranged from 41.8% to 84.8%. The results indicated that the raters failed to assess the same push-up repetition with the same score (below 70% agreement) as well as failed to agree when viewed between raters (29%). Interestingly, as previously mentioned, scores on trial 4 increased significantly which might have been caused by rater drift or that the Raters did not maintain the push-up standard over the trials. It does appear that the final push-up scores received by each participant was a close approximation of actual performance (within 65%) but when assessing physical performance for retention in the Army, a more reliable test might be considered. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  19. Evaluation of normality and reproducibility parameters of scintigraphy with (99m)Tc-MAA in the diagnosis of intrapulmonary vascular dilatations.

    PubMed

    de Queirós, Andréa Simone Siqueira; Brandão, Simone Cristina Soares; Macedo, Liana Gonçalves; Ourem, Maira Souto; Mota, Vitor Gomes; Leite, Luiz Arthur Calheiros; Lopes, Edmundo Pessoa Almeida; Domingues, Ana Lúcia Coutinho

    2015-01-01

    The formation of intrapulmonary vascular dilations (IPVD) is the key event for the onset of hepatopulmonary syndrome, vascular changes secondary to portal hypertension that leads to hypoxemia. The diagnosis of IPVD can be made by contrasted transthoracic echocardiography or scintigraphy with technetium-macroaggregated albumin-((99m)Tc-MAA)-that is a sensitive and specific diagnostic method and quantifies the IPVD magnitude. However, its procedure and diagnostic indices are not yet standardized and well defined in health services. The aims of this study were to define normality values and evaluate the inter- and intra-observer reproducibility degree of diagnostic indexes of IPVD through (99m)Tc-MAA scintigraphy. Cross-sectional study was conducted at the Clinical Hospital, Federal University of Pernambuco (HC-UFPE) between July and December 2012. Fifteen patients with hepatosplenic schistosomiasis and nine patients without liver or heart disease (control group) were assessed. After clinical assessment, ultrasound and echocardiography, patients underwent (99m)Tc-MAA scintigraphy, and a relative brain uptake value exceeding 6 % or systemic uptake value exceeding 11 % was considered diagnostic of IPVD. Each assessment was performed by two independent observers. To analyze the results of the normal group, the nonparametric Bootsptrap method simulation model combined with the Monte Carlo method was used and to analyze inter- and intra-observer reproducibility indexes, the kappa and intra-class correlation coefficient were used. In normal subjects, the average brain uptake of (99m)Tc-MAA was 7.9 ± 0.01 % and systemic uptake was 12.4 ± 0.03 %, with low dispersal rates for both measures. The intra-observer agreement was 100 %, with kappa index of 1.0 (p < 0.0001), suggesting a perfect agreement. The inter-observer agreement was also 100 % (kappa = 1.0, p < 0.0001) for brain uptake; however, systemic uptake showed kappa = 0.25 (p = 0.07), which features tolerable concordance. The intra-class correlation was excellent for both uptake indexes. The normality values were slightly higher than those reported in studies from other countries. The demographic characteristics of the Brazilian population, the small number of patients or different methodologies can be the causes of such differences. (99m)Tc-MAA scintigraphy showed excellent reproducibility.

  20. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    PubMed

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  1. Photographic Assessment of Baseline Fundus Morphology in the Comparison of Age-related Macular Degeneration Treatments Trials

    PubMed Central

    Grunwald, Juan E.; Daniel, Ebenezer; Ying, Gui-shuang; Pistilli, Maxwell; Maguire, Maureen G.; Alexander, Judith; Whittock-Martin, Revell; Parker, Candace R.; Sepielli, Krista; Blodi, Barbara A.; Martin, Daniel F.

    2012-01-01

    Objective To describe the methods used for assessment of baseline fundus characteristics from color photography and fluorescein angiography (FA) in the Comparison of the Age-Related Macular Degeneration Treatments Trials (CATT), and the relationship between these characteristics and visual acuity. Design Randomized, masked, multicenter trial. Participants This investigation included 1185 participants of the CATT study. Methods Baseline stereoscopic color fundus photographs and FAs of participants in the CATT study were assessed at a central fundus photograph reading center by masked readers. Replicate assessments of random samples of photographs were performed to assess intra- and inter-grader agreements. The association of the lesion characteristics with baseline visual acuity was assessed using analyses of variance and correlation coefficients. Main Outcome Measures Intra- and inter-grader reproducibility, visual acuity and lesion characteristics. Results Intra- and inter-grader reproducibility showed agreements ranging from 75% to 100% and weighted kappas ranging from 0.48 to 1.0 for qualitative determinations. The intra-class correlation coefficients were 0.96-0.97 for quantitative measurements of choroidal neovascularization (CNV) area and total area of CNV lesion. The mean visual acuity (SE) varied by the type of pathology in the foveal center: 64.5 (0.7) letters for fluid only, 59.0 (0.5) for CNV, and 58.7 (1.3) for hemorrhage (p<0.001). Fibrotic or atrophic scar present in the lesion, but not under the center of the fovea, was also associated with a markedly reduced visual acuity 48.4 (2.2), p<0.0001. Although total area of CNV lesion was weakly correlated with visual acuity when all participants were assessed (Spearman correlation coefficient ρ= −0.16, p<0.001), the correlation was stronger within patients with predominantly classic lesions (ρ=−0.42, p<0.001). Conclusions Our results show that the methodology used for grading CATT fundus images has good reproducibility. As expected, larger total CNV lesion area, and pathologic findings such as hemorrhage, fibrosis and atrophy at baseline are associated with decreased visual acuity. Financial Disclosures The authors have no proprietary or commercial interests in any materials discussed in this article. PMID:22512984

  2. Comparison of 3D computer-aided with manual cerebral aneurysm measurements in different imaging modalities.

    PubMed

    Groth, M; Forkert, N D; Buhk, J H; Schoenfeld, M; Goebell, E; Fiehler, J

    2013-02-01

    To compare intra- and inter-observer reliability of aneurysm measurements obtained by a 3D computer-aided technique with standard manual aneurysm measurements in different imaging modalities. A total of 21 patients with 29 cerebral aneurysms were studied. All patients underwent digital subtraction angiography (DSA), contrast-enhanced (CE-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA). Aneurysm neck and depth diameters were manually measured by two observers in each modality. Additionally, semi-automatic computer-aided diameter measurements were performed using 3D vessel surface models derived from CE- (CE-com) and TOF-MRA (TOF-com) datasets. Bland-Altman analysis (BA) and intra-class correlation coefficient (ICC) were used to evaluate intra- and inter-observer agreement. BA revealed the narrowest relative limits of intra- and inter-observer agreement for aneurysm neck and depth diameters obtained by TOF-com (ranging between ±5.3 % and ±28.3 %) and CE-com (ranging between ±23.3 % and ±38.1 %). Direct measurements in DSA, TOF-MRA and CE-MRA showed considerably wider limits of agreement. The highest ICCs were observed for TOF-com and CE-com (ICC values, 0.92 or higher for intra- as well as inter-observer reliability). Computer-aided aneurysm measurement in 3D offers improved intra- and inter-observer reliability and a reproducible parameter extraction, which may be used in clinical routine and as objective surrogate end-points in clinical trials.

  3. Evaluation of the coagulometer STA R Max® (Stago) for routine coagulation parameters.

    PubMed

    Brulé, Justine; Sinegre, Thomas; Pereira, Bruno; Berger, Marc G; Serre-Sapin, Anne-Françoise; Lebreton, Aurélien

    2018-04-01

    The STA R Max ® is a fully automated multiparameter coagulometer using clotting (viscosity-based detection system), chromogenic and immunologic assays. STA R Max ® is equipped with an innovative software (STA Coag Expert ® ) designed to assist laboratory in accreditation. The aim of this study was to evaluate its performances for the certification according to ISO 15189 quality standard in the haemostasis unit of our university hospital. The following tests were evaluated: prothrombin time (PT), activated partial thromboplastin time (aPTT), kaolin cephalin clotting time (KCCT), fibrinogen, anti-Xa assay and D-dimers. In normal and pathological range, the intra-assay coefficients of variation (CV) for PT, aPTT, KCCT and fibrinogen were below 4.0%. Intra-assay CV was of 4.0% for the anti-Xa assay and intra-assay CV was of 7.9% for D-dimers. Inter-assay CV were below 5.0% for PT, aPPT, KCCT and fibrinogen, 14.9% for anti-Xa assay and 8.6% for D-dimers. The interlaboratory comparisons were below 8.7% for PT, aPPT and KCCT, 5.0% for fibrinogen and 15.5% for anti-Xa assay. All results were acceptable according to suitable CV established by GFHT and the provider. The concordance between all coagulometers was excellent, with correlation coefficient close to 1 (0.99 for all parameters except for aPPT which was 0.98) calculated thanks to an intra-class correlation study. In conclusion, the STA R Max ® analyser is suitable for haemostasis laboratories and facilitates certification of a laboratory.

  4. Intra- and inter-rater reliability of digital image analysis for skin color measurement

    PubMed Central

    Sommers, Marilyn; Beacham, Barbara; Baker, Rachel; Fargo, Jamison

    2013-01-01

    Background We determined the intra- and inter-rater reliability of data from digital image color analysis between an expert and novice analyst. Methods Following training, the expert and novice independently analyzed 210 randomly ordered images. Both analysts used Adobe® Photoshop lasso or color sampler tools based on the type of image file. After color correction with Pictocolor® in camera software, they recorded L*a*b* (L*=light/dark; a*=red/green; b*=yellow/blue) color values for all skin sites. We computed intra-rater and inter-rater agreement within anatomical region, color value (L*, a*, b*), and technique (lasso, color sampler) using a series of one-way intra-class correlation coefficients (ICCs). Results Results of ICCs for intra-rater agreement showed high levels of internal consistency reliability within each rater for the lasso technique (ICC ≥ 0.99) and somewhat lower, yet acceptable, level of agreement for the color sampler technique (ICC = 0.91 for expert, ICC = 0.81 for novice). Skin L*, skin b*, and labia L* values reached the highest level of agreement (ICC ≥ 0.92) and skin a*, labia b*, and vaginal wall b* were the lowest (ICC ≥ 0.64). Conclusion Data from novice analysts can achieve high levels of agreement with data from expert analysts with training and the use of a detailed, standard protocol. PMID:23551208

  5. Intra- and inter-rater reliability of digital image analysis for skin color measurement.

    PubMed

    Sommers, Marilyn; Beacham, Barbara; Baker, Rachel; Fargo, Jamison

    2013-11-01

    We determined the intra- and inter-rater reliability of data from digital image color analysis between an expert and novice analyst. Following training, the expert and novice independently analyzed 210 randomly ordered images. Both analysts used Adobe(®) Photoshop lasso or color sampler tools based on the type of image file. After color correction with Pictocolor(®) in camera software, they recorded L*a*b* (L*=light/dark; a*=red/green; b*=yellow/blue) color values for all skin sites. We computed intra-rater and inter-rater agreement within anatomical region, color value (L*, a*, b*), and technique (lasso, color sampler) using a series of one-way intra-class correlation coefficients (ICCs). Results of ICCs for intra-rater agreement showed high levels of internal consistency reliability within each rater for the lasso technique (ICC ≥ 0.99) and somewhat lower, yet acceptable, level of agreement for the color sampler technique (ICC = 0.91 for expert, ICC = 0.81 for novice). Skin L*, skin b*, and labia L* values reached the highest level of agreement (ICC ≥ 0.92) and skin a*, labia b*, and vaginal wall b* were the lowest (ICC ≥ 0.64). Data from novice analysts can achieve high levels of agreement with data from expert analysts with training and the use of a detailed, standard protocol. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Arm cranking versus wheelchair propulsion for testing aerobic fitness in children with spina bifida who are wheelchair dependent.

    PubMed

    Bloemen, Manon A T; de Groot, Janke F; Backx, Frank J G; Westerveld, Rosalyne A; Takken, Tim

    2015-05-01

    To determine the best test performance and feasibility using a Graded Arm Cranking Test vs a Graded Wheelchair Propulsion Test in young people with spina bifida who use a wheelchair, and to determine the reliability of the best test. Validity and reliability study. Young people with spina bifida who use a wheelchair. Physiological responses were measured during a Graded Arm Cranking Test and a Graded Wheelchair Propulsion Test using a heart rate monitor and calibrated mobile gas analysis system (Cortex Metamax). For validity, peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) were compared using paired t-tests. For reliability, the intra-class correlation coefficients, standard error of measurement, and standard detectable change were calculated. VO2peak and HRpeak were higher during wheelchair propulsion compared with arm cranking (23.1 vs 19.5 ml/kg/min, p = 0.11; 165 vs 150 beats/min, p < 0.05). Reliability of wheelchair propulsion showed high intra-class correlation coefficients (ICCs) for both VO2peak (ICC = 0.93) and HRpeak (ICC = 0.90). This pilot study shows higher HRpeak and a tendency to higher VO2peak in young people with spina bifida who are using a wheelchair when tested during wheelchair propulsion compared with arm cranking. Wheelchair propulsion showed good reliability. We recommend performing a wheelchair propulsion test for aerobic fitness testing in this population.

  7. The reliability of the Adelaide in-shoe foot model.

    PubMed

    Bishop, Chris; Hillier, Susan; Thewlis, Dominic

    2017-07-01

    Understanding the biomechanics of the foot is essential for many areas of research and clinical practice such as orthotic interventions and footwear development. Despite the widespread attention paid to the biomechanics of the foot during gait, what largely remains unknown is how the foot moves inside the shoe. This study investigated the reliability of the Adelaide In-Shoe Foot Model, which was designed to quantify in-shoe foot kinematics and kinetics during walking. Intra-rater reliability was assessed in 30 participants over five walking trials whilst wearing shoes during two data collection sessions, separated by one week. Sufficient reliability for use was interpreted as a coefficient of multiple correlation and intra-class correlation coefficient of >0.61. Inter-rater reliability was investigated separately in a second sample of 10 adults by two researchers with experience in applying markers for the purpose of motion analysis. The results indicated good consistency in waveform estimation for most kinematic and kinetic data, as well as good inter-and intra-rater reliability. The exception is the peak medial ground reaction force, the minimum abduction angle and the peak abduction/adduction external hindfoot joint moments which resulted in less than acceptable repeatability. Based on our results, the Adelaide in-shoe foot model can be used with confidence for 24 commonly measured biomechanical variables during shod walking. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Morphology vs morphokinetics: a retrospective comparison of inter-observer and intra-observer agreement between embryologists on blastocysts with known implantation outcome.

    PubMed

    Adolfsson, Emma; Andershed, Anna Nowosad

    2018-06-18

    Our primary aim was to compare the morphology and morphokinetics on inter- and intra-observer agreement for blastocyst with known implantation outcome. Our secondary aim was to validate the morphokinetic parameters' ability to predict pregnancy using a previous published selection algorithm, and to compare this to standard morphology assessments. Two embryologists made independent blinded annotations on two occasions using time-lapse images and morphology evaluations using the Gardner Schoolcraft criteria of 99 blastocysts with known implantation outcome. Inter- and intra-observer agreement was calculated and compared using the two methods. The embryos were grouped based on their morphological score, and on their morphokinetic class using a previous published selection algorithm. The implantation rates for each group was calculated and compared. There was moderate agreement for morphology, with agreement on the same embryo score in 55 of 99 cases. The highest agreement rate was found for expansion grade, followed by trophectoderm and inner cell mass. Correlation with pregnancy was inconclusive. For morphokinetics, almost perfect agreement was found for early and late embryo development events, and strong agreement for day-2 and day-3 events. When applying the selection algorithm, the embryo distributions were uneven, and correlation to pregnancy was inconclusive. Time-lapse annotation is consistent and accurate, but our external validation of a previously published selection algorithm was unsuccessful.

  9. Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill

    PubMed Central

    2013-01-01

    Background Handrim wheelchair propulsion is a complex bimanual motor task. The bimanually applied forces on the rims determine the speed and direction of locomotion. Measurements of forces and torques on the handrim are important to study status and change of propulsion technique (and consequently mechanical strain) due to processes of learning, training or the wheelchair configuration. The purpose of this study was to compare the simultaneous outcomes of two different measurement-wheels attached to the different sides of the wheelchair, to determine measurement consistency within and between these wheels given the expected inter- and intra-limb variability as a consequence of motor control. Methods Nine able-bodied subjects received a three-week low-intensity handrim wheelchair practice intervention. They then performed three four-minute trials of wheelchair propulsion in an instrumented hand rim wheelchair on a motor-driven treadmill at a fixed belt speed. The two measurement-wheels on each side of the wheelchair measured forces and torques of one of the two upper limbs, which simultaneously perform the push action over time. The resulting data were compared as direct output using cross-correlation on the torque around the wheel-axle. Calculated push characteristics such as power production and speed were compared using an intra-class correlation. Results Measured torque around the wheel axle of the two measurement-wheels had a high average cross-correlation of 0.98 (std=0.01). Unilateral mean power output over a minute was found to have an intra-class correlation of 0.89 between the wheels. Although the difference over the pushes between left and right power output had a high variability, the mean difference between the measurement-wheels was low at 0.03 W (std=1.60). Other push characteristics showed even higher ICC’s (>0.9). Conclusions A good agreement between both measurement-wheels was found at the level of the power output. This indicates a high comparability of the measurement-wheels for the different propulsion parameters. Data from both wheels seem suitable to be used together or interchangeably in experiments on motor control and wheelchair propulsion performance. A high variability in forces and timing between the left and right side were found during the execution of this bimanual task, reflecting the human motor control process. PMID:23360756

  10. Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill.

    PubMed

    Vegter, Riemer J K; Lamoth, Claudine J; de Groot, Sonja; Veeger, Dirkjan H E J; van der Woude, Lucas H V

    2013-01-29

    Handrim wheelchair propulsion is a complex bimanual motor task. The bimanually applied forces on the rims determine the speed and direction of locomotion. Measurements of forces and torques on the handrim are important to study status and change of propulsion technique (and consequently mechanical strain) due to processes of learning, training or the wheelchair configuration. The purpose of this study was to compare the simultaneous outcomes of two different measurement-wheels attached to the different sides of the wheelchair, to determine measurement consistency within and between these wheels given the expected inter- and intra-limb variability as a consequence of motor control. Nine able-bodied subjects received a three-week low-intensity handrim wheelchair practice intervention. They then performed three four-minute trials of wheelchair propulsion in an instrumented hand rim wheelchair on a motor-driven treadmill at a fixed belt speed. The two measurement-wheels on each side of the wheelchair measured forces and torques of one of the two upper limbs, which simultaneously perform the push action over time. The resulting data were compared as direct output using cross-correlation on the torque around the wheel-axle. Calculated push characteristics such as power production and speed were compared using an intra-class correlation. Measured torque around the wheel axle of the two measurement-wheels had a high average cross-correlation of 0.98 (std=0.01). Unilateral mean power output over a minute was found to have an intra-class correlation of 0.89 between the wheels. Although the difference over the pushes between left and right power output had a high variability, the mean difference between the measurement-wheels was low at 0.03 W (std=1.60). Other push characteristics showed even higher ICC's (>0.9). A good agreement between both measurement-wheels was found at the level of the power output. This indicates a high comparability of the measurement-wheels for the different propulsion parameters. Data from both wheels seem suitable to be used together or interchangeably in experiments on motor control and wheelchair propulsion performance. A high variability in forces and timing between the left and right side were found during the execution of this bimanual task, reflecting the human motor control process.

  11. Validation of the Hindi version of National Institute of Health Stroke Scale.

    PubMed

    Prasad, Kameshwar; Dash, Deepa; Kumar, Amit

    2012-01-01

    To determine the reliability and validity of the National Institute of Health Stroke Scale (NIHSS) with the Hindi and Indian adaptation of items 9 and 10. NIHSS items 9 and 10 were modified and culturally adapted at All India Institute of Medical Sciences (AIIMS) and the resulting version was termed as Hindi version (HV-NIHSS). HV-NIHSS was applied by two independent investigators on 107 patients with stroke. Inter-observer agreement and intra-class correlation coefficients were calculated. The predictive validity of the HV-NIHSS was calculated using functional outcome after three months in the form of modified Rankin Scale (mRS) and Barthel Index (BI). The study included 107 patients of stroke recruited from a tertiary referral hospital at Delhi between November 1, 2009, and October 1, 2010; the mean age of these patients was 56.26±13.84 years and 65.4% of them had suffered ischemic stroke. Inter-rater reliability was high between the two examiners, with Pearson's r ranging from 0.72 to 0.99 for the 15 items on the Scale. Intra-class correlation coefficient for the total score was 0.995 (95% CI-0.993-0.997). Concurrent construct validity was established between HV-NIHSS and baseline Glasgow Coma Scale, with a high correlation (Spearman coefficient = -0.863, P<.001). Predictive validity was also established with BI at three months (Spearman's rho: -0.829, P<.001) and with mRS at three months (Spearman's rho: 0.851, P<0.001). This study shows that a Hindi language version of the NIHSS developed at AIIMS appears reliable and valid when applied to a Hindi-speaking population.

  12. Robust estimation of fractal measures for characterizing the structural complexity of the human brain: optimization and reproducibility

    PubMed Central

    Goñi, Joaquín; Sporns, Olaf; Cheng, Hu; Aznárez-Sanado, Maite; Wang, Yang; Josa, Santiago; Arrondo, Gonzalo; Mathews, Vincent P; Hummer, Tom A; Kronenberger, William G; Avena-Koenigsberger, Andrea; Saykin, Andrew J.; Pastor, María A.

    2013-01-01

    High-resolution isotropic three-dimensional reconstructions of human brain gray and white matter structures can be characterized to quantify aspects of their shape, volume and topological complexity. In particular, methods based on fractal analysis have been applied in neuroimaging studies to quantify the structural complexity of the brain in both healthy and impaired conditions. The usefulness of such measures for characterizing individual differences in brain structure critically depends on their within-subject reproducibility in order to allow the robust detection of between-subject differences. This study analyzes key analytic parameters of three fractal-based methods that rely on the box-counting algorithm with the aim to maximize within-subject reproducibility of the fractal characterizations of different brain objects, including the pial surface, the cortical ribbon volume, the white matter volume and the grey matter/white matter boundary. Two separate datasets originating from different imaging centers were analyzed, comprising, 50 subjects with three and 24 subjects with four successive scanning sessions per subject, respectively. The reproducibility of fractal measures was statistically assessed by computing their intra-class correlations. Results reveal differences between different fractal estimators and allow the identification of several parameters that are critical for high reproducibility. Highest reproducibility with intra-class correlations in the range of 0.9–0.95 is achieved with the correlation dimension. Further analyses of the fractal dimensions of parcellated cortical and subcortical gray matter regions suggest robustly estimated and region-specific patterns of individual variability. These results are valuable for defining appropriate parameter configurations when studying changes in fractal descriptors of human brain structure, for instance in studies of neurological diseases that do not allow repeated measurements or for disease-course longitudinal studies. PMID:23831414

  13. Patient Assessment of Constipation Quality of Life Questionnaire: Translation, Cultural Adaptation, Reliability, and Validity of the Persian Version.

    PubMed

    Nikjooy, Afsaneh; Jafari, Hassan; Saba, Maryam A; Ebrahimi, Naghmeh; Mirzaei, Rezvan

    2018-05-01

    The Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire is the most validated and the most specific tool for measuring the quality of life of patients with constipation. Over 120 million people live in countries whose official language is Persian. There is no reported Persian version of the PAC-QOL questionnaire yet. The aim of this study was to translate and culturally adapt the PAC-QOL questionnaire and to assess its reliability and validity among Persian patients with chronic constipation. Following the translation and cultural adaptation of the PAC-QOL questionnaire to Persian, 100 patients (mean±SD age=40.51±13.67) with constipation were recruited for validity measurement and 20 patients were re-examined for reliability. Content validity was assessed based on the opinions of an expert committee and the floor/ceiling effect. Construct validity was evaluated according to the hypothesis test. The SF-36 questionnaire was used for concurrent criterion validity, intra-class correlation coefficient for reliability, and Cronbach's alpha for internal consistency. The content validity of the PAC-QOL questionnaire was proven, and there was no floor/ceiling effect. Construct validity also was confirmed based on the hypothesis test. The overall Cronbach's alpha of the PAC-QOL questionnaire was 0.92 (range=0.72-0.92), and the overall intra-class correlation coefficient of the questionnaire was 0.88 (range=0.69-0.87). The correlation between the SF-36 and PAC-QOL questionnaires was moderate. The Persian version of the PAC-QOL questionnaire demonstrated good validity and reliability properties in chronic constipation. Accordingly, Persian researchers and clinicians can benefit from this questionnaire in further research and assessment of treatment outcomes.

  14. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    PubMed

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  15. Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab(®).

    PubMed

    Anthonissen, Mieke; Daly, Daniel; Fieuws, Steffen; Massagé, Patrick; Van Brussel, Michel; Vranckx, Jan; Van den Kerckhove, Eric

    2013-05-01

    This cross-sectional study investigated the reproducibility of repeated elasticity and transepidermal water loss (TEWL) measurements with the DermaLab(®) on 32 active burn scars and healthy skin. Intra- and inter-observer reproducibility was examined by means of intra-class correlation coefficients (ICC) and standard error of measurements (SEM). Results showed good ICC values and rather high SEM values for inter- and intra-observer reproducibility of elasticity measurements. For TEWL measurements, ICC values were good and SEM values were high for inter- and intra-observer reproducibility. There was a significant difference between the estimated mean elasticity values of normal skin and grafted scars and between normal skin and spontaneously healed scars (p≤0.003). For the estimated mean TEWL values, there was a significant difference between normal skin and spontaneously healed scars (p=0.036). A significant negative relation was reported between mean TEWL and time after burn (p=0.008). In clinical trials it is necessary to interpret patient-specific changes in elasticity and TEWL with caution, since the SEMs of both modes are rather high. We therefore recommend the use of a mean of repeated measurements of elasticity and TEWL to decrease the SEM. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  16. Tooth size discrepancies in Class II division 1 and Class III malocclusion requiring surgical-orthodontic or orthodontic treatment.

    PubMed

    McSwiney, Timothy P; Millett, Declan T; McIntyre, Grant T; Barry, Mark K; Cronin, Michael S

    2014-06-01

    To compare mean anterior (AR) and mean overall (OR) tooth size ratios, prevalence of clinically significant tooth size discrepancies (TSDs) and correlation between AR and OR in subjects with Class II division 1 and Class III malocclusion treated by surgical-orthodontic or orthodontic means. Retrospective, cross-sectional. State-funded and private clinics. From pre-treatment cohorts of 770 surgical and 610 non-surgical subjects, Class II division 1 and Class III malocclusion groups were identified with 60 surgical and 60 non-surgical subjects, comprising 30 males and 30 females, in each. AR and OR were calculated by landmarking digital models. Differences in AR and OR and their relationship were analysed using two-way analysis of variance (ANOVA) and a correlation coefficient, respectively. The proportions of the surgical and non-surgical groups with a TSD were assessed using logistic regression. Intra-examiner reproducibility involved re-landmarking 30 randomly selected image sets and differences in ARs and ORs were compared using a paired t-test. Random error was assessed using the intraclass correlation coefficient (ICC). Analyses were performed using SAS (SAS Institute Inc., Cary, NC, USA) at the 5% level of significance. There were no statistically significant differences associated with the measurement of either the mean AR (P = 0·913) or the mean OR (P = 0·874). ICC values were very high (AR = 0·95; OR = 0·90). Differences existed between both Class II and Class III surgical (AR: P<0·001; OR: P<0·001) and non-surgical groups (AR: P = 0·012; OR: P = 0·003). The AR and OR relationship was strong (correlation coefficient = 0·72). The highest percentage of clinically significant TSDs was seen in the AR of both Class II and Class III surgical groups (23·3%). In the cohort examined: AR and OR differed significantly for malocclusion groups. The prevalence of clinically significant TSDs did not differ significantly between surgical and non-surgical groups although the highest percentage of clinically significant TSDs was recorded for AR in Class II and Class III surgical cases. AR and OR were closely related. © 2014 British Orthodontic Society.

  17. Translation into Brazilian Portuguese, cross-cultural adaptation and validation of the Stanford presenteeism scale-6 and work instability scale for ankylosing spondylitis.

    PubMed

    Frauendorf, Renata; de Medeiros Pinheiro, Marcelo; Ciconelli, Rozana Mesquita

    2014-12-01

    Loss of productivity at work, as a result of health problems, is becoming an issue of interest due to the high burden it represents in society. The measurement of such phenomenon can be made using generic and specific scales for certain diseases such as the Stanford Presenteeism Scale (SPS-6) and the Work Instability Scale for Ankylosing Spondylitis (AS-WIS), specific for patients with ankylosing spondylitis (AS). The aim of this study was to translate and perform a cross-cultural adaptation of SPS-6 and AS-WIS into Portuguese and check their psychometric properties. The study also aimed to evaluate the relationship between the general scores of the scales and the main sociodemographic and clinical data, lifestyles, and absenteeism in patients with AS and correlate these variables with SPS-6 and AS-WIS scales. A sample of 120 patients with AS and 80 workers at a university hospital was evaluated. The processes for the translation and cross-cultural adaptation of the instruments followed preestablished steps and rules presented in the literature. For the evaluation of measurement properties and correlations between scales, intra-class correlation coefficient (reproducibility analysis), Cronbach alpha (internal consistency), and Pearson correlation coefficient (validity) were employed. The inter-observer (0.986) and intra-observer (0.992) reproducibilities of the AS-WIS were shown to be high as well as the internal consistency (0.995). Similarly, the inter-observer reliability of SPS-6 was considered good (0.890), although it showed a poorer performance when considering the same observer (Pearson correlation coefficient = 0.675 and intra-class correlation = 0.656). Internal consistency, for the total number of items, as measured by Cronbach alpha, was 0.889. The validity of the scales was evaluated thru the comparison of the achieved scores with the results of the WLQ, SF-36, ASQoL, BASFI, BASDAI, HAQ-S, and SRQ-20 instruments. Correlations between loss of productivity at work, worse quality of life, presence of emotional disturbances, and worse health conditions were positive. The process of translation, cross-cultural adaptation, and validation of the SPS-6 as a generic measurement for the loss of productivity at work and of the AS-WIS as a specific measurement for patients with AS are valid, reproducible, and specific instruments to be used in Brazil. In both scales, productivity at work was associated to advanced age, higher rate of absenteeism in the last month and year, presence of peripheral arthritis, and a larger number of comorbidities in patients with AS. The AS-WIS and SPS-6 showed a good correlation among them although they are not mutually exclusive but supplementary.

  18. Three dimensional reliability analyses of currently used methods for assessment of sagittal jaw discrepancy

    PubMed Central

    Almaqrami, Bushra-Sufyan; Alhammadi, Maged-Sultan

    2018-01-01

    Background The objective of this study was to analyse three dimensionally the reliability and correlation of angular and linear measurements in assessment of anteroposterior skeletal discrepancy. Material and Methods In this retrospective cross sectional study, a sample of 213 subjects were three-dimensionally analysed from cone-beam computed tomography scans. The sample was divided according to three dimensional measurement of anteroposterior relation (ANB angle) into three groups (skeletal Class I, Class II and Class III). The anterior-posterior cephalometric indicators were measured on volumetric images using Anatomage software (InVivo5.2). These measurements included three angular and seven linear measurements. Cross tabulations were performed to correlate the ANB angle with each method. Intra-class Correlation Coefficient (ICC) test was applied for the difference between the two reliability measurements. P value of < 0.05 was considered significant. Results There was a statistically significant (P<0.05) agreement between all methods used with variability in assessment of different anteroposterior relations. The highest correlation was between ANB and DSOJ (0.913), strong correlation with AB/FH, AB/SN/, MM bisector, AB/PP, Wits appraisal (0.896, 0.890, 0.878, 0.867,and 0.858, respectively), moderate with AD/SN and Beta angle (0.787 and 0.760), and weak correlation with corrected ANB angle (0.550). Conclusions Conjunctive usage of ANB angle with DSOJ, AB/FH, AB/SN/, MM bisector, AB/PP and Wits appraisal in 3D cephalometric analysis provide a more reliable and valid indicator of the skeletal anteroposterior relationship. Clinical relevance: Most of orthodontic literature depends on single method (ANB) with its drawbacks in assessment of skeletal discrepancy which is a cardinal factors for proper treatment planning, this study assessed three dimensionally the degree of correlation between all available methods to make clinical judgement more accurate based on more than one method of assessment. Key words:Anteroposterior relationships, ANB angle, Three-dimension, CBCT. PMID:29750096

  19. The Reliability and Validity of the Computerized Double Inclinometer in Measuring Lumbar Mobility

    PubMed Central

    MacDermid, Joy Christine; Arumugam, Vanitha; Vincent, Joshua Israel; Carroll, Krista L

    2014-01-01

    Study Design : Repeated measures reliability/validity study. Objectives : To determine the concurrent validity, test-retest, inter-rater and intra-rater reliability of lumbar flexion and extension measurements using the Tracker M.E. computerized dual inclinometer (CDI) in comparison to the modified-modified Schober (MMS) Summary of Background : Numerous studies have evaluated the reliability and validity of the various methods of measuring spinal motion, but the results are inconsistent. Differences in equipment and techniques make it difficult to correlate results. Methods : Twenty subjects with back pain and twenty without back pain were selected through convenience sampling. Two examiners measured sagittal plane lumbar range of motion for each subject. Two separate tests with the CDI and one test with the MMS were conducted. Each test consisted of three trials. Instrument and examiner order was randomly assigned. Intra-class correlations (ICCs 2, 2 and 2, 2) and Pearson correlation coefficients (r) were used to calculate reliability and concurrent validity respectively. Results : Intra-trial reliability was high to very high for both the CDI (ICCs 0.85 - 0.96) and MMS (ICCs 0.84 - 0.98). However, the reliability was poor to moderate, when the CDI unit had to be repositioned either by the same rate (ICCs 0.16 - 0.59) or a different rater (ICCs 0.45 - 0.52). Inter-rater reliability for the MMS was moderate to high (ICCs 0.75 - 0.82) which bettered the moderate correlation obtained for the CDI (ICCs 0.45 - 0.52). Correlations between the CDI and MMS were poor for flexion (0.32; p<0.05) and poor to moderate (-0.42 - -0.51; p<0.05) for extension measurements. Conclusion : When using the CDI, an average of subsequent tests is required to obtain moderate reliability. The MMS was highly reliable than the CDI. The MMS and the CDI measure lumbar movement on a different metric that are not highly related to each other. PMID:25352928

  20. Patterns of dietary habits in relation to obesity in Iranian adults.

    PubMed

    Saneei, Parvane; Esmaillzadeh, Ahmad; Keshteli, Ammar Hassanzadeh; Feizi, Awat; Feinle-Bisset, Christine; Adibi, Peyman

    2016-03-01

    Findings from few studies that investigated the relation between dietary behaviors and obesity are inconsistent. We aimed to assess the relation between patterns of dietary habits, identified by latent class analysis (LCA), and obesity in a large sample of Iranian adults. In a cross-sectional study on 7958 adults, dietary behaviors were assessed in five domains (meal patterns, eating rate, intra-meal fluid intake, meal-to-sleep interval, and fatty foods intake) using a pretested questionnaire. LCA was applied to identify classes of diet-related practices. Anthropometric measures were assessed through the use of a validated self-reported questionnaire. General and abdominal obesity were defined as a body mass index ≥ 30 kg/m(2), and a waist circumference ≥ 88 cm for women and ≥ 102 cm for men. General and abdominal obesity were prevalent in 9.7 and 27.7 % of the study population, respectively. We identified three distinct classes of eating rates (moderate, moderate to slow, and moderate to fast), two classes of meal patterns (regular and irregular), two classes of intra-meal fluid intake (moderate and more intra-meal drinking), three classes of meal-to-sleep interval (short, moderate, and long meal-to-sleep interval), and three classes of fatty food intake (low to moderate, moderate to high, and low intake of fatty foods). After adjustment for potential confounders, individuals with 'irregular meal pattern' were 21, 24, and 22 % more likely to be overweight/obese, abdominally overweight/obese, and abdominally obese, compared with those who had a 'regular meal pattern.' Individuals with 'more intra-meal drinking' had greater odds of overweight (OR 1.37; 1.19-1.458) and obesity (OR 1.51; 1.16-1.97) than those with 'moderate intra-meal drinking.' Moderate-to-high intake of fatty foods was inversely associated with abdominally overweight/obese (OR 0.85; 0.73-1.00) and abdominally obesity (OR 0.80; 0.68-0.96) compared with 'low-to-moderate intake of fatty foods.' No significant association was observed between eating rate, meal-to-sleep interval, and general or abdominal obesity, after controlling for confounders. Irregular meal pattern and more intra-meal drinking were associated with increased odds of general and abdominal obesity, whereas moderate-to-high intake of fatty foods was related to the decreased odds of central obesity among Iranian adults.

  1. Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study

    PubMed Central

    Baschung Pfister, Pierrette; Sterkele, Iris; Maurer, Britta; de Bie, Rob A.; Knols, Ruud H.

    2018-01-01

    Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75–0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64–0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20–0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups. PMID:29596450

  2. Concordance of actigraphy with polysomnography in children with and without attention-deficit/hyperactivity disorder.

    PubMed

    Waldon, Jessica; Begum, Esmot; Gendron, Melissa; Rusak, Benjamin; Andreou, Pantelis; Rajda, Malgorzata; Corkum, Penny

    2016-10-01

    This study sought to: (1) compare actigraphy-derived estimated sleep variables to the same variables based on the gold-standard of sleep assessment, polysomnography; (2) examine whether the correlations between the measures differ between children with attention-deficit/hyperactivity disorder and typically developing children; and (3) determine whether these correlations are altered when children with attention-deficit/hyperactivity disorder are treated with medication. Participants (24 attention-deficit/hyperactivity disorder; 24 typically developing), aged 6-12 years, completed a 1-week baseline assessment of typical sleep and daytime functioning. Following the baseline week, participants in the attention-deficit/hyperactivity disorder group completed a 4-week blinded randomized control trial of methylphenidate hydrochloride, including a 2-week placebo and 2-week methylphenidate hydrochloride treatment period. At the end of each observation (typically developing: baseline; attention-deficit/hyperactivity disorder: baseline, placebo and methylphenidate hydrochloride treatment), all participants were invited to a sleep research laboratory, where overnight polysomnography and actigraphy were recorded concurrently. Findings from intra-class correlations and Bland-Altman plots were consistent. Actigraphy was found to provide good estimates (e.g. intra-class correlations >0.61) of polysomnography results for sleep duration for all groups and conditions, as well as for sleep-onset latency and sleep efficiency for the typically developing group and attention-deficit/hyperactivity disorder group while on medication, but not for the attention-deficit/hyperactivity disorder group during baseline or placebo. Based on the Bland-Altman plots, actigraphy tended to underestimate for sleep duration (8.6-18.5 min), sleep efficiency (5.6-9.3%) and sleep-onset latency, except for attention-deficit/hyperactivity disorder during placebo in which actigraphy overestimated (-2.1 to 6.3 min). The results of the current study highlight the importance of utilizing a multimodal approach to sleep assessment in children with attention-deficit/hyperactivity disorder. © 2016 European Sleep Research Society.

  3. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    PubMed

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  4. Cross-cultural Adaptation of the "Functional Activities Questionnaire - FAQ" for use in Brazil

    PubMed Central

    Sanchez, Maria Angélica dos Santos; Correa, Pricila Cristina Ribeiro; Lourenço, Roberto Alves

    2011-01-01

    Objective The aim of this paper was to present the results of the first stage of cross-cultural adaptation of the Functional Activities Questionnaire (FAQ). Methods The tool was subjected to translation and re-translation, and the test-retest reliability of a proposed version for use in Brazil was analyzed. Results Of the 548 questionnaire respondents, a convenience sample of 68 informants was selected for retesting. Internal consistency was measured by Cronbach's alpha (0.95) while test-retest reliability was assessed using intra-class correlation (0.97). The findings have shown that FAQ is brief - averaging seven minutes to apply, easily understood and has good intra-rater test-retest reliability. Conclusion Our results suggest this adapted version of the FAQ is a reliable and stable tool which may be useful for assessing function in Brazilian elderly. Notwithstanding, the version should be subjected to further analysis with the aim of reaching functional equivalence. PMID:29213759

  5. Radiologic analysis of hindfoot alignment: Comparison of Méary, long axial, and hindfoot alignment views.

    PubMed

    Neri, T; Barthelemy, R; Tourné, Y

    2017-12-01

    Among radiographic views available for assessing hindfoot alignment, the antero-posterior weight-bearing view with metal cerclage of the hindfoot (Méary view) is the most widely used in France. Internationally, the long axial view (LAV) and hindfoot alignment view (HAV) are used also. The objective of this study was to compare the reliability of these three views. The Méary view with cerclage of the hindfoot is as reliable as the LAV and HAV for assessing hindfoot alignment. All three views were obtained in each of 22 prospectively included patients. Intra-observer and inter-observer reliabilities were assessed by having two observers collect the radiographic measurements then computing the intra-class correlation coefficients (ICCs). The intra-observer and inter-observer ICCs were 0.956 and 0.988 with the Méary view, 0.990 and 0.765 with the HAV, and 0.997 and 0.991 with the LAV, respectively. Correlations were far stronger between the LAV and HAV than between each of these and the Méary view. Compared to the LAV and HAV, the Méary view indicated a greater degree of hindfoot valgus. Intra-observer reliability was excellent with both the LAV and HAV, whereas inter-observer reliability was better with the LAV. Excellent reliability was also obtained with the Méary view. Combining the Méary view to obtain a radiographic image of the clinical deformity with the LAV to measure the angular deviation of the hindfoot axis may be useful when assessing hindfoot malalignment. A comparison of the three views in a larger population is needed before clinical recommendations can be made. II, prospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Acceptability and characteristics of 124 human bioequivalence studies with active substances classified according to the Biopharmaceutic Classification System

    PubMed Central

    Ramirez, Elena; Laosa, Olga; Guerra, Pedro; Duque, Blanca; Mosquera, Beatriz; Borobia, Alberto M; Lei, Suhua H; Carcas, Antonio J; Frias, Jesus

    2010-01-01

    AIM The aim of this study was to evaluate the acceptability of 124 bioequivalence (BE) studies with 80 active substances categorized according to the Biopharmaceutics Classification System (BCS) in order to establish if there were different probabilities of proving BE between the different BCS classes. METHODS We evaluated the differences between pharmaceutical products with active substances from different BCS classes in terms of acceptability, number of subjects in the study (n), the point estimates, and intra- and inter-subject coefficients of variation data from BE studies with generic products. RESULTS Out of 124 BE studies 89 (71.77%) were performed with pharmaceutical products containing active substances classified by the BCS. In all BCS classes there were non-bioequivalent pharmaceutical products: 4 out of 26 (15.38%) in class 1, 14 out of 28 (50%) in class 2, 3 out of 22 (13.63%) in class 3 and 1 out of 13 (7.69%) in class 4. When we removed those pharmaceutical products in which intra-subject variability was higher than predicted (2 in class 1 active substances, 9 in class 2 and 2 in class 3) there were still non-BE pharmaceutical products in classes 1, 2 and 3. CONCLUSIONS Comparisons between pharmaceutical products with active substances from the four BCS classes have not allowed us to define differential characteristics of each class in terms of n, inter and intra-subject variability for Cmax or AUC. Despite the usually employed test dissolution methodology proposed as quality control, pharmaceutical products with active substances from the four classes of BCS showed non-BE studies. PMID:21039763

  7. Evidence of Perturbations of the Cytokine Network in Preterm Labor

    PubMed Central

    Romero, Roberto; Grivel, Jean-Charles; Tarca, Adi L.; Chaemsaithong, Piya; Xu, Zhonghui; Fitzgerald, Wendy; Hassan, Sonia S.; Chaiworapongsa, Tinnakorn; Margolis, Leonid

    2015-01-01

    Objective Intra-amniotic infection/inflammation is the only mechanism of disease with persuasive evidence of causality for spontaneous preterm labor/delivery. Previous studies about the behavior of cytokines in preterm labor have been largely based on the analysis of the behavior of each protein independently. Emerging evidence indicates that the study of biological networks can provide insight into the pathobiology of disease, and improve biomarker discovery. The goal of this study is to characterize the inflammatory-related proteins network in the amniotic fluid in patients with preterm labor. Materials and Methods A retrospective cohort study was conducted, and included women with singleton pregnancies who presented with spontaneous preterm labor and intact membranes (n=135). These patients were classified according to the results of amniotic fluid culture, broad-range polymerase chain reaction coupled with electrospray ionization mass spectrometry (PCR/ESI-MS), and amniotic fluid concentration of interleukin (IL)-6 into the following groups: 1) those without intra-amniotic inflammation (n=85); 2) those with microbial-associated intra-amniotic inflammation (n=15); and 3) those with intra-amniotic inflammation without detectable bacteria (n=35). Amniotic fluid concentrations of 33 inflammatory-related proteins were determined using a multiplex bead array assay. Results 1) Patients with preterm labor and intact membranes who had microbial-associated intra-amniotic inflammation had a higher amniotic fluid inflammatory-related protein concentration correlation than those without intra-amniotic inflammation (113 perturbed correlations). IL-1β, IL-6, MIP-1α, and IL-1α were the most connected nodes (highest degree) in this differential correlation network (degree of 20, 16, 12, and 12, respectively); 2) patients with sterile intra-amniotic inflammation had correlation patterns of inflammatory-related proteins that were both increased and decreased when compared to those without intra-amniotic inflammation (50 perturbed correlations). IL-1α, MIP-1α, and IL-1β were the most connected nodes in this differential correlation network (degrees of 12, 10, and 7, respectively); and 3) there were more coordinated inflammatory-related protein concentrations in the amniotic fluid of women with microbial-associated intra-amniotic inflammation than in those with sterile intra-amniotic inflammation (60 perturbed correlations), with IL-4 and IL-33 having the largest number of perturbed correlations (degree of 15 and 13, respectively). Conclusion We report for the first time an analysis of the inflammatory-related protein network in spontaneous preterm labor. Patients with preterm labor who had microbial-associated intra-amniotic inflammation had more coordinated amniotic fluid inflammatory-related proteins than either those with sterile intra-amniotic inflammation or those without intra-amniotic inflammation. The correlations were also stronger in patients with sterile intra-amniotic inflammation than in those without intra-amniotic inflammation. The findings herein could be of value in the development of biomarkers of preterm labor. PMID:26232508

  8. Intra-rater reliability of electromyographic recordings and subjective evaluation of neck muscle fatigue among helicopter pilots.

    PubMed

    Thuresson, Marcus; Ang, Björn; Linder, Jan; Harms-Ringdahl, Karin

    2005-06-01

    The aim was to evaluate the reliability of a method of measuring neck muscle fatigue among helicopter pilots. Surface EMG from three areas in the neck region, bilaterally, was recorded among 10 male helicopter pilots while they were performing isometric contractions in flexion and extension for 45 s, sustaining a force representing 75% of maximum strength in a seated position. Perceived fatigue was rated using the Borg CR-10 scale. The test was repeated twice the first day and then two additional times with one-week intervals. Variables analyzed were the slope of the median frequency change, the normalized slope, and the ratings after 15, 30 and 45 s; and also the initial median frequency (IMDF). The intra-class correlation (ICC) and the measurement error (S(w)), intra- and inter-day were calculated statistically. The best reliability for the slope was found for the 45 s intra-day analysis taking all measurements into account (ICC 0.65-0.83). The reliability after 30 s was poorer but still acceptable (ICC 0.52-0.71). For the subjective ratings, the highest reliability was found after 30 s inter-day (ICC 0.86-0.88). IMDF showed generally high reliability for the intra-day analyses (ICC 0.63-0.80). The method is reliable for use in further research. Since performing a contraction of 75% of maximum was quite strenuous, we recommend that the protocol be shortened to 30 s.

  9. Research of facial feature extraction based on MMC

    NASA Astrophysics Data System (ADS)

    Xue, Donglin; Zhao, Jiufen; Tang, Qinhong; Shi, Shaokun

    2017-07-01

    Based on the maximum margin criterion (MMC), a new algorithm of statistically uncorrelated optimal discriminant vectors and a new algorithm of orthogonal optimal discriminant vectors for feature extraction were proposed. The purpose of the maximum margin criterion is to maximize the inter-class scatter while simultaneously minimizing the intra-class scatter after the projection. Compared with original MMC method and principal component analysis (PCA) method, the proposed methods are better in terms of reducing or eliminating the statistically correlation between features and improving recognition rate. The experiment results on Olivetti Research Laboratory (ORL) face database shows that the new feature extraction method of statistically uncorrelated maximum margin criterion (SUMMC) are better in terms of recognition rate and stability. Besides, the relations between maximum margin criterion and Fisher criterion for feature extraction were revealed.

  10. Ultrasound discloses entheseal involvement in inactive and low active inflammatory bowel disease without clinical signs and symptoms of spondyloarthropathy.

    PubMed

    Bandinelli, Francesca; Milla, Monica; Genise, Stefania; Giovannini, Leonardo; Bagnoli, Siro; Candelieri, Antonio; Collaku, Ledio; Biagini, Silvia; Cerinic, Marco Matucci

    2011-07-01

    To investigate the presence of lower limb entheseal abnormalities in IBD patients without clinical signs and symptoms of SpA and their correlation with IBD clinical variables. A total of 81 IBD patients [55 Crohn's disease (CD) and 26 ulcerative colitis (UC), 43 females and 38 males, mean age 41.3 (12.4) years, BMI 24 (2)] with low active (12) and inactive (67) disease were consecutively studied with US (LOGIQ5 General Electric 10-MHz linear array transducer) of lower limb entheses and compared with 40 healthy controls matched for sex, age and BMI. Quadriceps, patellar, Achilleon and plantar fascia entheses were scored according to the 0-36 Glasgow Ultrasound Enthesitis Scoring System (GUESS) and power Doppler (PD). Correlations of GUESS and PD with IBD features [duration, type (CD/UC) and activity (disease activity index for CD/Truelove score for UC)] were investigated. The intra- and inter-reader agreements for US were estimated in all images detected in patients and controls. Of the 81 patients, 71 (92.6%) presented almost one tendon alteration with mean GUESS 5.1 (3.5): 81.5% thickness (higher than controls P < 0.05), 67.9% enthesophytosis, 27.1% bursitis and 16.1% erosions. PD was positive in 13/81 (16%) patients. In controls, US showed only enthesophytes (5%) and no PD. GUESS and PD were independent of duration, activity or type (CD/UC) of IBD. The intra- and inter-reader agreements were high (>0.9 intra-class correlation variability). US entheseal abnormalities are present in IBD patients without clinical signs and symptoms of SpA. US enthesopathy is independent of activity, duration and type of gut disease.

  11. Reliability and convergent validity of the five-step test in people with chronic stroke.

    PubMed

    Ng, Shamay S M; Tse, Mimi M Y; Tam, Eric W C; Lai, Cynthia Y Y

    2018-01-10

    (i) To estimate the intra-rater, inter-rater and test-retest reliabilities of the Five-Step Test (FST), as well as the minimum detectable change in FST completion times in people with stroke. (ii) To estimate the convergent validity of the FST with other measures of stroke-specific impairments. (iii) To identify the best cut-off times for distinguishing FST performance in people with stroke from that of healthy older adults. A cross-sectional study. University-based rehabilitation centre. Forty-eight people with stroke and 39 healthy controls. None. The FST, along with (for the stroke survivors only) scores on the Fugl-Meyer Lower Extremity Assessment (FMA-LE), the Berg Balance Scale (BBS), Limits of Stability (LOS) tests, and Activities-specific Balance Confidence (ABC) scale were tested. The FST showed excellent intra-rater (intra-class correlation coefficient; ICC = 0.866-0.905), inter-rater (ICC = 0.998), and test-retest (ICC = 0.838-0.842) reliabilities. A minimum detectable change of 9.16 s was found for the FST in people with stroke. The FST correlated significantly with the FMA-LE, BBS, and LOS results in the forward and sideways directions (r = -0.411 to -0.716, p < 0.004). The FST completion time of 13.35 s was shown to discriminate reliably between people with stroke and healthy older adults. The FST is a reliable, easy-to-administer clinical test for assessing stroke survivors' ability to negotiate steps and stairs.

  12. Reliability of the Test of Integrated Language and Literacy Skills (TILLS).

    PubMed

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A; Applegate, E Brooks; Nelson, Nickola W

    2016-07-01

    As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated Language and Literacy Skills (TILLS), with consideration of both internal and external sources of measurement error. The TILLS was administered to children aged 6;0-18;11 years. The participants varied in terms of their language and literacy skills and included children with typical language development as well as those diagnosed with language or learning disability. The sample of children also varied in terms of their racial and socioeconomic backgrounds. Study 1 (N = 1056) assessed the internal consistency of TILLS calculating the coefficient omega for each subtest. Study 2 (N = 103) and Study 3 (N = 39) used the intra-class correlation coefficients to report on test-retest and inter-rater reliability respectively. The results indicate strong internal consistency and inter-rater reliability for all subtests of TILLS. The test-retest reliability was strong for all but one subtest, for which the intra-class correlation coefficient was in the acceptable range. This article provides clinicians with essential scientific information that supports the internal and external reliability of a new test of oral and written language skills, the TILLS. Information about reliability is critical for guiding the selection of an appropriate diagnostic tool amongst a number of options. © 2016 Royal College of Speech and Language Therapists.

  13. Reliability of pulse waveform separation analysis: effects of posture and fasting.

    PubMed

    Stoner, Lee; Credeur, Daniel; Fryer, Simon; Faulkner, James; Lambrick, Danielle; Gibbs, Bethany Barone

    2017-03-01

    Oscillometric pulse wave analysis devices enable, with relative simplicity and objectivity, the measurement of central hemodynamic parameters. The important parameters are central blood pressures and indices of arterial wave reflection, including wave separation analysis (backward pressure component Pb and reflection magnitude). This study sought to determine whether the measurement precision (between-day reliability) of Pb and reflection magnitude: exceeds the criterion for acceptable reliability; and is affected by posture (supine, seated) and fasting state. Twenty healthy adults (50% female, 27.9 years, 24.2 kg/m) were tested on six different mornings: 3 days fasted, 3 days nonfasted condition. On each occasion, participants were tested in supine and seated postures. Oscillometric pressure waveforms were recorded on the left upper arm. The criterion intra-class correlation coefficient value of 0.75 was exceeded for Pb (0.76) and reflection magnitude (0.77) when participants were assessed under the combined supine-fasted condition. The intra-class correlation coefficient was lowest for Pb in seated-nonfasted condition (0.57), and lowest for reflection magnitude in the seated-fasted condition (0.56). For Pb, the smallest detectible change that must be exceeded in order for a significant change to occur in an individual was 2.5 mmHg, and for reflection magnitude, the smallest detectable change was 8.5%. Assessments of Pb and reflection magnitude are as follows: exceed the criterion for acceptable reliability; and are most reliable when participants are fasted in a supine position. The demonstrated reliability suggests sufficient precision to detect clinically meaningful changes in reflection magnitude and Pb.

  14. Analysis of Intra- and Intersubject Variability in Oral Drug Absorption in Human Bioequivalence Studies of 113 Generic Products.

    PubMed

    Sugihara, Masahisa; Takeuchi, Susumu; Sugita, Masaru; Higaki, Kazutaka; Kataoka, Makoto; Yamashita, Shinji

    2015-12-07

    In this study, the data of 113 human bioequivalence (BE) studies of immediate release (IR) formulations of 74 active pharmaceutical ingredients (APIs) conducted at Sawai Pharmaceutical Co., Ltd., was analyzed to understand the factors affecting intra- and intersubject variabilities in oral drug absorption. The ANOVA CV (%) calculated from area under the time-concentration curve (AUC) in each BE study was used as an index of intrasubject variability (Vintra), and the relative standard deviation (%) in AUC was used as that of intersubject variability (Vinter). Although no significant correlation was observed between Vintra and Vinter of all drugs, Vintra of class 3 drugs was found to increase in association with a decrease in drug permeability (P(eff)). Since the absorption of class 3 drugs was rate-limited by the permeability, it was suggested that, for such drugs, the low P(eff) might be a risk factor to cause a large intrasubject variability. To consider the impact of poor water solubility on the variability in BE study, a parameter of P(eff)/Do (Do; dose number) was defined to discriminate the solubility-limited and dissolution-rate-limited absorption of class 2 drugs. It was found that the class 2 drugs with a solubility-limited absorption (P(eff)/Do < 0.149 × 10(-4) cm/s) showed high intrasubject variability. Furthermore, as a reason for high intra- or intersubject variability in AUC for class 1 drugs, effects of drug metabolizing enzymes were investigated. It was demonstrated that intrasubject variability was high for drugs metabolized by CYP3A4 while intersubject variability was high for drugs metabolized by CYP2D6. For CYP3A4 substrate drugs, the Km value showed the significant relation with Vintra, indicating that the affinity to the enzyme can be a parameter to predict the risk of high intrasubject variability. In conclusion, by analyzing the in house data of human BE study, low permeability, solubility-limited absorption, and high affinity to CYP3A4 are identified as risk factors for high intrasubject variability in oral drug absorption. This information is of importance to design the human BE study for oral drug products containing APIs with a risk of large intrasubject variability in oral absorption.

  15. Advancements in automated tissue segmentation pipeline for contrast-enhanced CT scans of adult and pediatric patients

    NASA Astrophysics Data System (ADS)

    Somasundaram, Elanchezhian; Kaufman, Robert; Brady, Samuel

    2017-03-01

    The development of a random forests machine learning technique is presented for fully-automated neck, chest, abdomen, and pelvis tissue segmentation of CT images using Trainable WEKA (Waikato Environment for Knowledge Analysis) Segmentation (TWS) plugin of FIJI (ImageJ, NIH). The use of a single classifier model to segment six tissue classes (lung, fat, muscle, solid organ, blood/contrast agent, bone) in the CT images is studied. An automated unbiased scheme to sample pixels from the training images and generate a balanced training dataset over the seven classes is also developed. Two independent training datasets are generated from a pool of 4 adult (>55 kg) and 3 pediatric patients (<=55 kg) with 7 manually contoured slices for each patient. Classifier training investigated 28 image filters comprising a total of 272 features. Highly correlated and insignificant features are eliminated using Correlated Feature Subset (CFS) selection with Best First Search (BFS) algorithms in WEKA. The 2 training models (from the 2 training datasets) had 74 and 71 input training features, respectively. The study also investigated the effect of varying the number of trees (25, 50, 100, and 200) in the random forest algorithm. The performance of the 2 classifier models are evaluated on inter-patient intra-slice, intrapatient inter-slice and inter-patient inter-slice test datasets. The Dice similarity coefficients (DSC) and confusion matrices are used to understand the performance of the classifiers across the tissue segments. The effect of number of features in the training input on the performance of the classifiers for tissue classes with less than optimal DSC values is also studied. The average DSC values for the two training models on the inter-patient intra-slice test data are: 0.98, 0.89, 0.87, 0.79, 0.68, and 0.84, for lung, fat, muscle, solid organ, blood/contrast agent, and bone, respectively. The study demonstrated that a robust segmentation accuracy for lung, muscle and fat tissue classes. For solid-organ, blood/contrast and bone, the performance of the segmentation pipeline improved significantly by using the advanced capabilities of WEKA. However, further improvements are needed to reduce the noise in the segmentation.

  16. Impact of non-uniform correlation structure on sample size and power in multiple-period cluster randomised trials.

    PubMed

    Kasza, J; Hemming, K; Hooper, R; Matthews, Jns; Forbes, A B

    2017-01-01

    Stepped wedge and cluster randomised crossover trials are examples of cluster randomised designs conducted over multiple time periods that are being used with increasing frequency in health research. Recent systematic reviews of both of these designs indicate that the within-cluster correlation is typically taken account of in the analysis of data using a random intercept mixed model, implying a constant correlation between any two individuals in the same cluster no matter how far apart in time they are measured: within-period and between-period intra-cluster correlations are assumed to be identical. Recently proposed extensions allow the within- and between-period intra-cluster correlations to differ, although these methods require that all between-period intra-cluster correlations are identical, which may not be appropriate in all situations. Motivated by a proposed intensive care cluster randomised trial, we propose an alternative correlation structure for repeated cross-sectional multiple-period cluster randomised trials in which the between-period intra-cluster correlation is allowed to decay depending on the distance between measurements. We present results for the variance of treatment effect estimators for varying amounts of decay, investigating the consequences of the variation in decay on sample size planning for stepped wedge, cluster crossover and multiple-period parallel-arm cluster randomised trials. We also investigate the impact of assuming constant between-period intra-cluster correlations instead of decaying between-period intra-cluster correlations. Our results indicate that in certain design configurations, including the one corresponding to the proposed trial, a correlation decay can have an important impact on variances of treatment effect estimators, and hence on sample size and power. An R Shiny app allows readers to interactively explore the impact of correlation decay.

  17. Reliability of doming and toe flexion testing to quantify foot muscle strength.

    PubMed

    Ridge, Sarah Trager; Myrer, J William; Olsen, Mark T; Jurgensmeier, Kevin; Johnson, A Wayne

    2017-01-01

    Quantifying the strength of the intrinsic foot muscles has been a challenge for clinicians and researchers. The reliable measurement of this strength is important in order to assess weakness, which may contribute to a variety of functional issues in the foot and lower leg, including plantar fasciitis and hallux valgus. This study reports 3 novel methods for measuring foot strength - doming (previously unmeasured), hallux flexion, and flexion of the lesser toes. Twenty-one healthy volunteers performed the strength tests during two testing sessions which occurred one to five days apart. Each participant performed each series of strength tests (doming, hallux flexion, and lesser toe flexion) four times during the first testing session (twice with each of two raters) and two times during the second testing session (once with each rater). Intra-class correlation coefficients were calculated to test for reliability for the following comparisons: between raters during the same testing session on the same day (inter-rater, intra-day, intra-session), between raters on different days (inter-rater, inter-day, inter-session), between days for the same rater (intra-rater, inter-day, inter-session), and between sessions on the same day by the same rater (intra-rater, intra-day, inter-session). ICCs showed good to excellent reliability for all tests between days, raters, and sessions. Average doming strength was 99.96 ± 47.04 N. Average hallux flexion strength was 65.66 ± 24.5 N. Average lateral toe flexion was 50.96 ± 22.54 N. These simple tests using relatively low cost equipment can be used for research or clinical purposes. If repeated testing will be conducted on the same participant, it is suggested that the same researcher or clinician perform the testing each time for optimal reliability.

  18. Reliability and Validity Study of the Chamorro Assisted Gait Scale for People with Sprained Ankles, Walking with Forearm Crutches

    PubMed Central

    Ridao-Fernández, Carmen; Ojeda, Joaquín; Benítez-Lugo, Marisa; Sevillano, José Luis

    2016-01-01

    Objective The aim of this study was to design and validate a functional assessment scale for assisted gait with forearm crutches (Chamorro Assisted Gait Scale—CHAGS) and to assess its reliability in people with sprained ankles. Design Thirty subjects who suffered from sprained ankle (anterior talofibular ligament first and second degree) were included in the study. A modified Delphi technique was used to obtain the content validity. The selected items were: pelvic and scapular girdle dissociation(1), deviation of Center of Gravity(2), crutch inclination(3), steps rhythm(4), symmetry of step length(5), cross support(6), simultaneous support of foot and crutch(7), forearm off(8), facing forward(9) and fluency(10). Two raters twice visualized the gait of the sample subjects which were recorded. The criterion-related validity was determined by correlation between CHAGS and Coding of eight criteria of qualitative gait analysis (Viel Coding). Internal consistency and inter and intra-rater reliability were also tested. Results CHAGS obtained a high and negative correlation with Viel Coding. We obtained a good internal consistency and the intra-class correlation coefficients oscillated between 0.97 and 0.99, while the minimal detectable changes were acceptable. Conclusion CHAGS scale is a valid and reliable tool for assessing assisted gait with crutches in people with sprained ankles to perform partial relief of lower limbs. PMID:27168236

  19. Psychiatric disorder and work life: A longitudinal study of intra-generational social mobility.

    PubMed

    Tiikkaja, Sanna; Sandin, Sven; Hultman, Christina M; Modin, Bitte; Malki, Ninoa; Sparén, Pär

    2016-03-01

    Intra-generational social mobility, which describes the mobility within an individual's own working life, is seldom studied among employees with psychiatric disorders (EPD). There is need of knowledge of the intra-generational mobility patterns, in a broader perspective, among EPD. To investigate intra-generational social mobility in employed individuals diagnosed with affective disorder, personality disorder, schizophrenia and drug dependence in a national Swedish cohort. We identified a national sample of employed Swedish adults born in 1939-1949 (N = 876, 738), and among them individuals with a first-time hospital admission for affective psychosis, neurosis and personality disorder, alcoholism, drug dependence or schizophrenia in 1964-1980 (N = 18, 998). Employed individuals without hospital admission for such diagnoses were utilised as a comparison group (N = 866, 442). Intra-individual social class changes between 1980 and 1990 among EPD and the comparison group were described through summary statistics and graphs. EPD more often held Low manual occupations at baseline in 1980 than the comparison group (44% vs. 28%), although parental social class was similar. In 1990, 19% of EPD and 4% of the comparison group had lost contact with the labour market. Social stability was less common among EPD (49 %) than in the comparison group (67%). Mobility out of the labour force increased and social stability decreased by number of inpatient admissions. Employees diagnosed with affective psychosis or neurosis and personality disorder fared better in the labour market than employees with schizophrenia. Employees suffering from psychiatric disorder do not maintain their social class or remain in the labour force to the same extent as individuals without those problems, irrespective of their parental class. Our results support the social drift hypothesis that individuals with poor psychiatric health move downward in the social hierarchy. © The Author(s) 2015.

  20. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    PubMed

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  1. Post-traumatic subtalar osteoarthritis: which grading system should we use?

    PubMed

    de Muinck Keizer, Robert-Jan O; Backes, Manouk; Dingemans, Siem A; Goslings, J Carel; Schepers, Tim

    2016-09-01

    To assess and compare post-traumatic osteoarthritis following intra-articular calcaneal fractures, one must have a reliable grading system that consistently grades the post-traumatic changes of the joint. A reliable grading system aids in the communication between treating physicians and improves the interpretation of research. To date, there is no consensus on what grading system to use in the evaluation of post-traumatic subtalar osteoarthritis. The objective of this study was to determine and compare the inter- and intra-rater reliability of two grading systems for post-traumatic subtalar osteoarthritis. Four observers evaluated 50 calcaneal fractures at least one year after trauma on conventional oblique lateral, internally and externally rotated views, and graded post-traumatic subtalar osteoarthritis using the Kellgren and Lawrence Grading Scale (KLGS) and the Paley Grading System (PGS). Inter- and intra-rater reliability were calculated and compared. The inter-rater reliability showed an intra-class correlation (ICC) of 0.54 (95 % CI 0.40-0.67) for the KLGS and an ICC of 0.41 (95 % CI 0.26 - 0.57) for the PGS. This difference was not statistically significant. The intra-rater reliability showed a mean weighted kappa of 0.62 for both the KLGS and the PGS. There is no statistically significant difference in reliability between the Kellgren and Lawrence Grading System (KLGS) and the Paley Grading System (PGS). The PGS allows for an easy two-step approach making it easy for everyday clinical purposes. For research purposes however, the more detailed and widely used KLGS seems preferable.

  2. Periodontal repair in dogs: examiner reproducibility in the supraalveolar periodontal defect model.

    PubMed

    Koo, Ki-Tae; Polimeni, Giuseppe; Albandar, Jasim M; Wikesjö, Ulf M E

    2004-06-01

    Histometric assessments are routinely used to evaluate biologic events ascertained in histologic sections acquired from animal and human studies. The objective of this study was to evaluate the intra- and inter-examiner reproducibility of histometric assessments in the supraalveolar periodontal defect model. Histometric analysis using incandescent and polarized light microscopy, an attached digital camera system, and a PC-based image analysis system including a custom program for the supraalveolar periodontal defect model was performed on histologic sections acquired from one jaw quadrant in each of 12 dogs. The animals had received an experimental protocol including implantation of a coral biomaterial and guided tissue regeneration (GTR) barrier devices, and were evaluated following a 4-week healing interval. Histometric parameters were recorded and repeated within a 3-month interval by two examiners following brief training. Intra- and inter-examiner reproducibility was assessed using the intra-class correlation coefficient (ICC). Most parameters showed high intra-examiner ICCs. Parameters including defect height, connective tissue repair, bone regeneration (height/area), formation of a junctional epithelium, positioning of the GTR device, ankylosis, root resorption, and defect area yielded an ICC> or 0..9. The ICCs for bone density and biomaterial density were somewhat lower (0.8 and 0.7, respectively). The inter-examiner reproducibility was somewhat lower compared to the intra-examiner reproducibility. Nevertheless, the ICCs were generally high (ICC range: 0.6-0.9). Histometric evaluations in the supraalveolar periodontal defect model yield highly reproducible results, in particular when a single examiner performs the histometric measurements, even when the examiner was exposed to limited training.

  3. Reliability of the AMA Guides to the Evaluation of Permanent Impairment.

    PubMed

    Forst, Linda; Friedman, Lee; Chukwu, Abraham

    2010-12-01

    AMA's Guides to the Evaluation of Permanent Impairment is used to rate loss of function and determine compensation and ability to work after injury or illness; however, there are few studies that evaluate reliability or construct validity. To evaluate the reliability of the fifth and sixth editions for back injury; to determine best methods for further study. Intra-class correlation coefficients within and between raters were relatively high. There was wider variability for individual cases. Impairment ratings were lower and correlated less well for the sixth edition, though confidence intervals overlapped. The sixth edition may not be an improvement over the fifth. A research agenda should include investigations of reliability and construct validity for different body sites and organ systems along the entire rating scale and among different categories of raters.

  4. Designing a composite correlation filter based on iterative optimization of training images for distortion invariant face recognition

    NASA Astrophysics Data System (ADS)

    Wang, Q.; Elbouz, M.; Alfalou, A.; Brosseau, C.

    2017-06-01

    We present a novel method to optimize the discrimination ability and noise robustness of composite filters. This method is based on the iterative preprocessing of training images which can extract boundary and detailed feature information of authentic training faces, thereby improving the peak-to-correlation energy (PCE) ratio of authentic faces and to be immune to intra-class variance and noise interference. By adding the training images directly, one can obtain a composite template with high discrimination ability and robustness for face recognition task. The proposed composite correlation filter does not involve any complicated mathematical analysis and computation which are often required in the design of correlation algorithms. Simulation tests have been conducted to check the effectiveness and feasibility of our proposal. Moreover, to assess robustness of composite filters using receiver operating characteristic (ROC) curves, we devise a new method to count the true positive and false positive rates for which the difference between PCE and threshold is involved.

  5. Validity of wearable activity monitors for tracking steps and estimating energy expenditure during a graded maximal treadmill test.

    PubMed

    Kendall, Bradley; Bellovary, Bryanne; Gothe, Neha P

    2018-06-04

    The purpose of this study was to assess the accuracy of energy expenditure (EE) estimation and step tracking abilities of six activity monitors (AMs) in relation to indirect calorimetry and hand counted steps and assess the accuracy of the AMs between high and low fit individuals in order to assess the impact of exercise intensity. Fifty participants wore the Basis watch, Fitbit Flex, Polar FT7, Jawbone, Omron pedometer, and Actigraph during a maximal graded treadmill test. Correlations, intra-class correlations, and t-tests determined accuracy and agreement between AMs and criterions. The results indicate that the Omron, Fitbit, and Actigraph were accurate for measuring steps while the Basis and Jawbone significantly underestimated steps. All AMs were significantly correlated with indirect calorimetry, however, no devices showed agreement (p < .05). When comparing low and high fit groups, correlations between AMs and indirect calorimetry improved for the low fit group, suggesting AMs may be better at measuring EE at lower intensity exercise.

  6. Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external phantom.

    PubMed

    Boomsma, Martijn F; Slouwerhof, Inge; van Dalen, Jorn A; Edens, Mireille A; Mueller, Dirk; Milles, Julien; Maas, Mario

    2015-11-01

    The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue.

  7. Temporal variability of urinary cadmium in spot urine samples and first morning voids.

    PubMed

    Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R

    2017-05-01

    Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.

  8. PERFORMANCE OF A COMPUTER-BASED ASSESSMENT OF COGNITIVE FUNCTION MEASURES IN TWO COHORTS OF SENIORS

    PubMed Central

    Espeland, Mark A.; Katula, Jeffrey A.; Rushing, Julia; Kramer, Arthur F.; Jennings, Janine M.; Sink, Kaycee M.; Nadkarni, Neelesh K.; Reid, Kieran F.; Castro, Cynthia M.; Church, Timothy; Kerwin, Diana R.; Williamson, Jeff D.; Marottoli, Richard A.; Rushing, Scott; Marsiske, Michael; Rapp, Stephen R.

    2013-01-01

    Background Computer-administered assessment of cognitive function is being increasingly incorporated in clinical trials, however its performance in these settings has not been systematically evaluated. Design The Seniors Health and Activity Research Program (SHARP) pilot trial (N=73) developed a computer-based tool for assessing memory performance and executive functioning. The Lifestyle Interventions and Independence for Seniors (LIFE) investigators incorporated this battery in a full scale multicenter clinical trial (N=1635). We describe relationships that test scores have with those from interviewer-administered cognitive function tests and risk factors for cognitive deficits and describe performance measures (completeness, intra-class correlations). Results Computer-based assessments of cognitive function had consistent relationships across the pilot and full scale trial cohorts with interviewer-administered assessments of cognitive function, age, and a measure of physical function. In the LIFE cohort, their external validity was further demonstrated by associations with other risk factors for cognitive dysfunction: education, hypertension, diabetes, and physical function. Acceptable levels of data completeness (>83%) were achieved on all computer-based measures, however rates of missing data were higher among older participants (odds ratio=1.06 for each additional year; p<0.001) and those who reported no current computer use (odds ratio=2.71; p<0.001). Intra-class correlations among clinics were at least as low (ICC≤0.013) as for interviewer measures (ICC≤0.023), reflecting good standardization. All cognitive measures loaded onto the first principal component (global cognitive function), which accounted for 40% of the overall variance. Conclusion Our results support the use of computer-based tools for assessing cognitive function in multicenter clinical trials of older individuals. PMID:23589390

  9. A comparison between laser-doppler imaging and colorimetry in the assessment of scarring: "a pilot study".

    PubMed

    Peeters, Wouter; Anthonissen, Mieke; Deliaert, An; Van der Hulst, Rene; Van den Kerckhove, Eric

    2012-05-01

    This cross-sectional pilot-study investigated the reproducibility of the LDI (Moor-LDI-B2; Moor Instruments) and the chromameter (Minolta chromameter CR-300) when used in scar assessment. Twenty-seven scars in 14 subjects were included between January and June 2003. One observer performed two times both measurements with 10 min apart. The intra-observer agreement is quantified by means of the intra-class correlations (ICC) and the standard errors of measurement (SEM) for both the LDI and the chromameter. Ignoring one outlier, the ICC of the LDI = 0.856 and the SEM = 34.56. The chromameter shows a better reproducibility with an ICC of 0.93 and a SEM of 0.79. This pilot-study with a limited number of measurements shows a moderate reproducibility of the LDI compared to the chromameter measurements, in the assessment of respectively flux and redness in scars. © 2011 John Wiley & Sons A/S.

  10. Measuring family-centred practices of professionals in early intervention services in Taiwan.

    PubMed

    Kang, L-J; Palisano, R J; Simeonsson, R J; Hwang, A-W

    2017-09-01

    Family-centred practices emphasize professional supports for forming partnerships with families in early intervention. The Measure of Processes of Care for Service Providers (MPOC-SP) measures the perceptions of paediatric service providers in supporting children and families. This study aimed to establish reliability of the Chinese version of the MPOC-SP (C-MPOC-SP) and to examine professional perceptions of family-centred practices in relation to professional discipline and years of experience. A convenience sample of 94 physical therapists, occupational therapists, speech-language pathologists, social workers and early childhood educators completed the C-MPOC-SP. Thirty-seven professionals completed the measure a second time within 2-4 weeks for test-retest reliability. Internal consistency and test-retest reliability were examined by Cronbach's α and intra-class correlation coefficient. Comparisons were made across professional disciplines by multivariate analyses of variance followed by analyses of variance. Relationships between years of experience and ratings of family-centred practices were examined by Pearson's correlation coefficients (r). Cronbach's α for items on each of the four scales of the C-MPOC-SP ranged from 0.80 to 0.92, indicating adequate internal consistency. Intra-class correlation coefficient between the initial and repeat completion of the C-MPOC-SP for each scale ranged from 0.56 to 0.77, indicating adequate to excellent test-retest reliability. Mean ratings for the Communicating Specific Information were significantly higher for physical therapists, occupational therapists and speech-language pathologists than for social workers (P = 0.001). The C-MPOC-SP scores were positively correlated with years of experience for all four scales (r = 0.23-0.38; P < 0.05). This study established adequate internal consistency and adequate to excellent test-retest reliability of the C-MPOC-SP in measuring perceptions of family centeredness of early intervention service providers. Cross-discipline differences were found in communicating specific information about the child. Higher perceptions of family centeredness were associated with more years of experience. The results support the utility of the C-MPOC-SP in professional education and programme evaluation of early intervention services in Taiwan. © 2017 John Wiley & Sons Ltd.

  11. Assessing the inter-observer variability of Computer-Aided Nodule Assessment and Risk Yield (CANARY) to characterize lung adenocarcinomas.

    PubMed

    Nakajima, Erica C; Frankland, Michael P; Johnson, Tucker F; Antic, Sanja L; Chen, Heidi; Chen, Sheau-Chiann; Karwoski, Ronald A; Walker, Ronald; Landman, Bennett A; Clay, Ryan D; Bartholmai, Brian J; Rajagopalan, Srinivasan; Peikert, Tobias; Massion, Pierre P; Maldonado, Fabien

    2018-01-01

    Lung adenocarcinoma (ADC), the most common lung cancer type, is recognized increasingly as a disease spectrum. To guide individualized patient care, a non-invasive means of distinguishing indolent from aggressive ADC subtypes is needed urgently. Computer-Aided Nodule Assessment and Risk Yield (CANARY) is a novel computed tomography (CT) tool that characterizes early ADCs by detecting nine distinct CT voxel classes, representing a spectrum of lepidic to invasive growth, within an ADC. CANARY characterization has been shown to correlate with ADC histology and patient outcomes. This study evaluated the inter-observer variability of CANARY analysis. Three novice observers segmented and analyzed independently 95 biopsy-confirmed lung ADCs from Vanderbilt University Medical Center/Nashville Veterans Administration Tennessee Valley Healthcare system (VUMC/TVHS) and the Mayo Clinic (Mayo). Inter-observer variability was measured using intra-class correlation coefficient (ICC). The average ICC for all CANARY classes was 0.828 (95% CI 0.76, 0.895) for the VUMC/TVHS cohort, and 0.852 (95% CI 0.804, 0.901) for the Mayo cohort. The most invasive voxel classes had the highest ICC values. To determine whether nodule size influenced inter-observer variability, an additional cohort of 49 sub-centimeter nodules from Mayo were also segmented by three observers, with similar ICC results. Our study demonstrates that CANARY ADC classification between novice CANARY users has an acceptably low degree of variability, and supports the further development of CANARY for clinical application.

  12. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals.

    PubMed

    Fuller, Joel T; Archer, Jane; Buckley, Jonathan D; Tsiros, Margarita D; Thewlis, Dominic

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5%; limits of agreement [LOA] ≤4.2%). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2%; LOA ≤11.9%). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2%; LOA ≤23.6%) and fourth metatarsals (ICC ≥0.67; CV ≤9.6%; LOA ≤27.5%). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals.

  13. Ultrasonographic measurements of lower trapezius muscle thickness at rest and during isometric contraction: a reliability study.

    PubMed

    Talbott, Nancy R; Witt, Dexter W

    2014-07-01

    The purpose of this study was to determine the intra-rater reliability and inter-rater reliability of ultrasound imaging (USI) thickness measurements of the lower trapezius (LT) at rest and during active contractions when the transverse process and the lamina were used as reference sites for the measurement process. Twenty healthy individuals between the ages of 22 and 32 years volunteered. With the subject prone and the shoulder in 145° of abduction, images of the LT were taken bilaterally by one examiner as the subject: (1) rested; (2) actively held the test position; and (3) actively held the test position while holding a weight. Ten subjects returned and testing was repeated by the same examiner and by a second examiner. LT thickness measurements were recorded at the level of the transverse process and at the level of the lamina. Intra-class correlation coefficients (ICC) for within session intra-rater reliability (ICC3,3) ranged from 0.951 to 0.986 for both measurement sites while between session intra-rater reliability (ICC3,2) ranged from 0.935 to 0.962. Within session inter-rater reliability (ICC2,2) ranged from 0.934 to 0.973. USI can be used to reliably measure LT thickness at rest, during active contraction and during active contraction when holding a weight. The described protocol can be utilized during shoulder examinations to provide an additional assessment tool for monitoring changes in LT thickness.

  14. Reliability of different methodologies of infrared image analysis of myofascial trigger points in the upper trapezius muscle

    PubMed Central

    Dibai-Filho, Almir V.; Guirro, Elaine C. O.; Ferreira, Vânia T. K.; Brandino, Hugo E.; Vaz, Maíta M. O. L. L.; Guirro, Rinaldo R. J.

    2015-01-01

    BACKGROUND: Infrared thermography is recognized as a viable method for evaluation of subjects with myofascial pain. OBJECTIVE: The aim of the present study was to assess the intra- and inter-rater reliability of infrared image analysis of myofascial trigger points in the upper trapezius muscle. METHOD: A reliability study was conducted with 24 volunteers of both genders (23 females) between 18 and 30 years of age (22.12±2.54), all having cervical pain and presence of active myofascial trigger point in the upper trapezius muscle. Two trained examiners performed analysis of point, line, and area of the infrared images at two different periods with a 1-week interval. The intra-class correlation coefficient (ICC2,1) was used to assess the intra- and inter-rater reliability. RESULTS: With regard to the intra-rater reliability, ICC values were between 0.591 and 0.993, with temperatures between 0.13 and 1.57 °C for values of standard error of measurement (SEM) and between 0.36 and 4.35 °C for the minimal detectable change (MDC). For the inter-rater reliability, ICC ranged from 0.615 to 0.918, with temperatures between 0.43 and 1.22 °C for the SEM and between 1.19 and 3.38 °C for the MDC. CONCLUSION: The methods of infrared image analyses of myofascial trigger points in the upper trapezius muscle employed in the present study are suitable for clinical and research practices. PMID:25993626

  15. Virtual Raters for Reproducible and Objective Assessments in Radiology

    NASA Astrophysics Data System (ADS)

    Kleesiek, Jens; Petersen, Jens; Döring, Markus; Maier-Hein, Klaus; Köthe, Ullrich; Wick, Wolfgang; Hamprecht, Fred A.; Bendszus, Martin; Biller, Armin

    2016-04-01

    Volumetric measurements in radiologic images are important for monitoring tumor growth and treatment response. To make these more reproducible and objective we introduce the concept of virtual raters (VRs). A virtual rater is obtained by combining knowledge of machine-learning algorithms trained with past annotations of multiple human raters with the instantaneous rating of one human expert. Thus, he is virtually guided by several experts. To evaluate the approach we perform experiments with multi-channel magnetic resonance imaging (MRI) data sets. Next to gross tumor volume (GTV) we also investigate subcategories like edema, contrast-enhancing and non-enhancing tumor. The first data set consists of N = 71 longitudinal follow-up scans of 15 patients suffering from glioblastoma (GB). The second data set comprises N = 30 scans of low- and high-grade gliomas. For comparison we computed Pearson Correlation, Intra-class Correlation Coefficient (ICC) and Dice score. Virtual raters always lead to an improvement w.r.t. inter- and intra-rater agreement. Comparing the 2D Response Assessment in Neuro-Oncology (RANO) measurements to the volumetric measurements of the virtual raters results in one-third of the cases in a deviating rating. Hence, we believe that our approach will have an impact on the evaluation of clinical studies as well as on routine imaging diagnostics.

  16. T2* mapping of hip joint cartilage in various histological grades of degeneration.

    PubMed

    Bittersohl, B; Miese, F R; Hosalkar, H S; Herten, M; Antoch, G; Krauspe, R; Zilkens, C

    2012-07-01

    To evaluate T2* values in various histological severities of osteoarthritis (OA). Magnetic resonance imaging (MRI) and T2* mapping including a three-dimensional (3D) double-echo steady-state (DESS) sequence for morphological cartilage assessment and a 3D multiecho data image combination (MEDIC) sequence for T2* mapping were conducted in 21 human femoral head specimens with varying severities of OA. Subsequently, histological assessment was undertaken in all specimens to correlate the observations of T2* mapping with histological analyses. According to the Mankin score, four grades of histological changes were determined: grade 0 (Mankin scores of 0-4), grade I (scores of 5-8), grade II (scores of 9-10), and grade III (scores of 11-14). For reliability assessment, cartilage T2* measurements were repeated after 4 weeks in 10 randomly selected femoral head specimens. T2* values decreased significantly with increasing cartilage degeneration (total P-values <0.001) ranging from 36.3 ± 4.3 ms in grade 0 regions to 22.8 ± 4.3 ms in regions with grade III changes. Pearson correlation analysis proved a fair correlation between T2* values and Mankin score (correlation coefficient = -0.362) that was statistically significant (P-value <0.001). Intra-class correlation (ICC) analysis demonstrated high intra-observer reproducibility for the T2* measurement (ICC: 0.949, P < 0.001). Given the advantages of the T2* mapping technique with no need for contrast medium, high image resolution and ability to perform 3D biochemically sensitive imaging, T2* mapping may be a strong addition to the currently evolving era of cartilage biochemical imaging. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  17. Operationalizing Max Weber's probability concept of class situation: the concept of social class.

    PubMed

    Smith, Ken

    2007-03-01

    In this essay I take seriously Max Weber's astonishingly neglected claim that class situation may be defined, not in categorial terms, but probabilistically. I then apply this idea to another equally neglected claim made by Weber that the boundaries of social classes may be determined by the degree of social mobility within such classes. Taking these two ideas together I develop the idea of a non-categorial boundary 'surface' between classes and of a social class 'corridor' made up of all those people who are still to be found within the boundaries of the social class into which they were born. I call social mobility within a social class 'intra-class social mobility' and social mobility between classes 'inter-class social mobility'. I also claim that this distinction resolves the dispute between those sociologists who claim that late industrial societies are still highly class bound and those who think that this is no longer the case. Both schools are right I think, but one is referring to a high degree of intra-class social mobility and the other to an equally high degree of inter-class mobility. Finally I claim that this essay provides sociology with only one example among many other possible applications of how probability theory might usefully be used to overcome boundary problems generally in sociology.

  18. Three-dimensional facial analysis of Chinese children with repaired unilateral cleft lip and palate

    NASA Astrophysics Data System (ADS)

    Othman, Siti Adibah; Aidil Koay, Noor Airin

    2016-08-01

    We analyzed the facial features of Chinese children with repaired unilateral cleft lip and palate (UCLP) and compared them with a normal control group using a three-dimensional (3D) stereophotogrammetry camera. This cross-sectional study examined 3D measurements of the facial surfaces of 20 Chinese children with repaired UCLP and 40 unaffected Chinese children aged 7 to 12 years old, which were captured using the VECTRA 3D five-pod photosystem and analyzed using Mirror software. Twenty-five variables and two ratios were compared between both groups using independent t-test. Intra- and inter-observer reliability was determined using ten randomly selected images and analyzed using intra-class correlation coefficient test (ICC). The level of significance was set at p < 0.0018. Intra- and inter-observers’ reliability was considered fair to excellent with an ICC value ranging from 0.54 to 0.99. Statistically significant differences (p < 0.0018) were found mainly in the nasolabial region. The cleft group exhibited wider alar base root width, flattened nose and broader nostril floor width on the cleft side. They tended to have shorter upper lip length and thinner upper vermillion thickness. Faces of Chinese children with repaired UCLP displayed meaningful differences when compared to the normal group especially in the nasolabial regions.

  19. Dynamic Contrast-enhanced MR Imaging in Renal Cell Carcinoma: Reproducibility of Histogram Analysis on Pharmacokinetic Parameters

    PubMed Central

    Wang, Hai-yi; Su, Zi-hua; Xu, Xiao; Sun, Zhi-peng; Duan, Fei-xue; Song, Yuan-yuan; Li, Lu; Wang, Ying-wei; Ma, Xin; Guo, Ai-tao; Ma, Lin; Ye, Hui-yi

    2016-01-01

    Pharmacokinetic parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) have been increasingly used to evaluate the permeability of tumor vessel. Histogram metrics are a recognized promising method of quantitative MR imaging that has been recently introduced in analysis of DCE-MRI pharmacokinetic parameters in oncology due to tumor heterogeneity. In this study, 21 patients with renal cell carcinoma (RCC) underwent paired DCE-MRI studies on a 3.0 T MR system. Extended Tofts model and population-based arterial input function were used to calculate kinetic parameters of RCC tumors. Mean value and histogram metrics (Mode, Skewness and Kurtosis) of each pharmacokinetic parameter were generated automatically using ImageJ software. Intra- and inter-observer reproducibility and scan–rescan reproducibility were evaluated using intra-class correlation coefficients (ICCs) and coefficient of variation (CoV). Our results demonstrated that the histogram method (Mode, Skewness and Kurtosis) was not superior to the conventional Mean value method in reproducibility evaluation on DCE-MRI pharmacokinetic parameters (K trans & Ve) in renal cell carcinoma, especially for Skewness and Kurtosis which showed lower intra-, inter-observer and scan-rescan reproducibility than Mean value. Our findings suggest that additional studies are necessary before wide incorporation of histogram metrics in quantitative analysis of DCE-MRI pharmacokinetic parameters. PMID:27380733

  20. [Spatial patterns of dominant tree species in sub-alpine Betula-Abies forest in West Sichuan of China].

    PubMed

    Miao, Ning; Liu, Shi-Rong; Shi, Zuo-Min; Yu, Hong; Liu, Xing-Liang

    2009-06-01

    Based on the investigation in a 4 hm2 Betula-Abies forest plot in sub-alpine area in West Sichuan of China, and by using point pattern analysis method in terms of O-ring statistics, the spatial patterns of dominant species Betula albo-sinensis and Abies faxoniana in different age classes in study area were analyzed, and the intra- and inter-species associations between these age classes were studied. B. albo-sinensis had a unimodal distribution of its DBH frequency, indicating a declining population, while A. faxoniana had a reverse J-shaped pattern, showing an increasing population. All the big trees of B. albo-sinensis and A. faxoniana were spatially in random at all scales, while the medium age and small trees were spatially clumped at small scales and tended to be randomly or evenly distributed with increasing spatial scale. The maximum aggregation degree decreased with increasing age class. Spatial association mainly occurred at small scales. A. faxoniana generally showed positive intra-specific association, while B. albo-sinensis generally showed negative intra-specific association. For the two populations, big and small trees had no significant spatial association, but middle age trees had negative spatial association. Negative inter-specific associations of the two populations were commonly found in different age classes. The larger the difference of age class, the stronger the negative inter-specific association.

  1. Feasibility and observer reproducibility of speckle tracking echocardiography in congenital heart disease patients.

    PubMed

    Mokhles, Palwasha; van den Bosch, Annemien E; Vletter-McGhie, Jackie S; Van Domburg, Ron T; Ruys, Titia P E; Kauer, Floris; Geleijnse, Marcel L; Roos-Hesselink, Jolien W

    2013-09-01

    The twisting motion of the heart has an important role in the function of the left ventricle. Speckle tracking echocardiography is able to quantify left ventricular (LV) rotation and twist. So far this new technique has not been used in congenital heart disease patients. The aim of our study was to investigate the feasibility and the intra- and inter-observer reproducibility of LV rotation parameters in adult patients with congenital heart disease. The study population consisted of 66 consecutive patients seen in the outpatient clinic (67% male, mean age 31 ± 7.7 years, NYHA class 1 ± 0.3) with a variety of congenital heart disease. First, feasibility was assessed in all patients. Intra- and inter-observer reproducibility was assessed for the patients in which speckle tracking echocardiography was feasible. Adequate image quality, for performing speckle echocardiography, was found in 80% of patients. The bias for the intra-observer reproducibility of the LV twist was 0.0°, with 95% limits of agreement of -2.5° and 2.5° and for interobserver reproducibility the bias was 0.0°, with 95% limits of agreement of -3.0° and 3.0°. Intra- and inter-observer measurements showed a strong correlation (0.86 and 0.79, respectively). Also a good repeatability was seen. The mean time to complete full analysis per subject for the first and second measurement was 9 and 5 minutes, respectively. Speckle tracking echocardiography is feasible in 80% of adult patients with congenital heart disease and shows excellent intra- and inter-observer reproducibility. © 2013, Wiley Periodicals, Inc.

  2. Reliability of sagittal plane hip, knee, and ankle joint angles from a single frame of video data using the GAITRite camera system.

    PubMed

    Ross, Sandy A; Rice, Clinton; Von Behren, Kristyn; Meyer, April; Alexander, Rachel; Murfin, Scott

    2015-01-01

    The purpose of this study was to establish intra-rater, intra-session, and inter-rater, reliability of sagittal plane hip, knee, and ankle angles with and without reflective markers using the GAITRite walkway and single video camera between student physical therapists and an experienced physical therapist. This study included thirty-two healthy participants age 20-59, stratified by age and gender. Participants performed three successful walks with and without markers applied to anatomical landmarks. GAITRite software was used to digitize sagittal hip, knee, and ankle angles at two phases of gait: (1) initial contact; and (2) mid-stance. Intra-rater reliability was more consistent for the experienced physical therapist, regardless of joint or phase of gait. Intra-session reliability was variable, the experienced physical therapist showed moderate to high reliability (intra-class correlation coefficient (ICC) = 0.50-0.89) and the student physical therapist showed very poor to high reliability (ICC = 0.07-0.85). Inter-rater reliability was highest during mid-stance at the knee with markers (ICC = 0.86) and lowest during mid-stance at the hip without markers (ICC = 0.25). Reliability of a single camera system, especially at the knee joint shows promise. Depending on the specific type of reliability, error can be attributed to the testers (e.g. lack of digitization practice and marker placement), participants (e.g. loose fitting clothing) and camera systems (e.g. frame rate and resolution). However, until the camera technology can be upgraded to a higher frame rate and resolution, and the software can be linked to the GAITRite walkway, the clinical utility for pre/post measures is limited.

  3. Intra-and inter-observer reliability of nailfold videocapillaroscopy - A possible outcome measure for systemic sclerosis-related microangiopathy.

    PubMed

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Tresadern, Philip; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-07-01

    Our aim was to assess the reliability of nailfold capillary assessment in terms of image evaluability, image severity grade ('normal', 'early', 'active', 'late'), capillary density, capillary (apex) width, and presence of giant capillaries, and also to gain further insight into differences in these parameters between patients with systemic sclerosis (SSc), patients with primary Raynaud's phenomenon (PRP) and healthy control subjects. Videocapillaroscopy images (magnification 300×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade ('normal', 'early', 'active', 'late', 'non-specific', or 'ungradeable'), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries. Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85). Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The Pfirrmann classification of lumbar intervertebral disc degeneration: an independent inter- and intra-observer agreement assessment.

    PubMed

    Urrutia, Julio; Besa, Pablo; Campos, Mauricio; Cikutovic, Pablo; Cabezon, Mario; Molina, Marcelo; Cruz, Juan Pablo

    2016-09-01

    Grading inter-vertebral disc degeneration (IDD) is important in the evaluation of many degenerative conditions, including patients with low back pain. Magnetic resonance imaging (MRI) is considered the best imaging instrument to evaluate IDD. The Pfirrmann classification is commonly used to grade IDD; the authors describing this classification showed an adequate agreement using it; however, there has been a paucity of independent agreement studies using this grading system. The aim of this study was to perform an independent inter- and intra-observer agreement study using the Pfirrmann classification. T2-weighted sagittal images of 79 patients consecutively studied with lumbar spine MRI were classified using the Pfirrmann grading system by six evaluators (three spine surgeons and three radiologists). After a 6-week interval, the 79 cases were presented to the same evaluators in a random sequence for repeat evaluation. The intra-class correlation coefficient (ICC) and the weighted kappa (wκ) were used to determine the inter- and intra-observer agreement. The inter-observer agreement was excellent, with an ICC = 0.94 (0.93-0.95) and wκ = 0.83 (0.74-0.91). There were no differences between spine surgeons and radiologists. Likewise, there were no differences in agreement evaluating the different lumbar discs. Most differences among observers were only of one grade. Intra-observer agreement was also excellent with ICC = 0.86 (0.83-0.89) and wκ = 0.89 (0.85-0.93). In this independent study, the Pfirrmann classification demonstrated an adequate agreement among different observers and by the same observer on separate occasions. Furthermore, it allows communication between radiologists and spine surgeons.

  5. Response variability of different anodal transcranial direct current stimulation intensities across multiple sessions.

    PubMed

    Ammann, Claudia; Lindquist, Martin A; Celnik, Pablo A

    It is well known that transcranial direct current stimulation (tDCS) is capable of modulating corticomotor excitability. However, a source of growing concern has been the observed inter- and intra-individual variability of tDCS-responses. Recent studies have assessed whether individuals respond in a predictable manner across repeated sessions of anodal tDCS (atDCS). The findings of these investigations have been inconsistent, and their methods have some limitations (i.e. lack of sham condition or testing only one tDCS intensity). To study inter- and intra-individual variability of atDCS effects at two different intensities on primary motor cortex (M1) excitability. Twelve subjects participated in a crossover study testing 7-min atDCS over M1 in three separate conditions (2 mA, 1 mA, sham) each repeated three times separated by 48 h. Motor evoked potentials were recorded before and after stimulation (up to 30min). Time of testing was maintained consistent within participants. To estimate the reliability of tDCS effects across sessions, we calculated the Intra-class Correlation Coefficient (ICC). AtDCS at 2 mA, but not 1 mA, significantly increased cortical excitability at the group level in all sessions. The overall ICC revealed fair to high reliability of tDCS effects for multiple sessions. Given that the distribution of responses showed important variability in the sham condition, we established a Sham Variability-Based Threshold to classify responses and to track individual changes across sessions. Using this threshold an intra-individual consistent response pattern was then observed only for the 2 mA condition. 2 mA anodal tDCS results in consistent intra- and inter-individual increases of M1 excitability. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    PubMed

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. 77 FR 77184 - Hotard Coaches, Inc. and Calco Travel, Inc.-Corporate Family Transaction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-31

    ... Coaches, Inc. and Calco Travel, Inc.--Corporate Family Transaction Hotard Coaches, Inc. (Hotard), a... notice has been redocketed as Docket No. MCF 21051. \\2\\ The Board exempted intra-corporate family... family in Class Exemption for Motor Passenger Intra-Corporate Family Transactions, FD 33285 (STB served...

  8. Disease Severity and Progression in Progressive Supranuclear Palsy and Multiple System Atrophy: Validation of the NNIPPS – PARKINSON PLUS SCALE

    PubMed Central

    Payan, Christine A. M.; Viallet, François; Landwehrmeyer, Bernhard G.; Bonnet, Anne-Marie; Borg, Michel; Durif, Franck; Lacomblez, Lucette; Bloch, Frédéric; Verny, Marc; Fermanian, Jacques; Agid, Yves; Ludolph, Albert C.

    2011-01-01

    Background The Natural History and Neuroprotection in Parkinson Plus Syndromes (NNIPPS) study was a large phase III randomized placebo-controlled trial of riluzole in Progressive Supranuclear Palsy (PSP, n = 362) and Multiple System Atrophy (MSA, n = 398). To assess disease severity and progression, we constructed and validated a new clinical rating scale as an ancillary study. Methods and Findings Patients were assessed at entry and 6-montly for up to 3 years. Evaluation of the scale's psychometric properties included reliability (n = 116), validity (n = 760), and responsiveness (n = 642). Among the 85 items of the initial scale, factor analysis revealed 83 items contributing to 15 clinically relevant dimensions, including Activity of daily Living/Mobility, Axial bradykinesia, Limb bradykinesia, Rigidity, Oculomotor, Cerebellar, Bulbar/Pseudo-bulbar, Mental, Orthostatic, Urinary, Limb dystonia, Axial dystonia, Pyramidal, Myoclonus and Tremor. All but the Pyramidal dimension demonstrated good internal consistency (Cronbach α≥0.70). Inter-rater reliability was high for the total score (Intra-class coefficient = 0.94) and 9 dimensions (Intra-class coefficient = 0.80–0.93), and moderate (Intra-class coefficient = 0.54–0.77) for 6. Correlations of the total score with other clinical measures of severity were good (rho≥0.70). The total score was significantly and linearly related to survival (p<0.0001). Responsiveness expressed as the Standardized Response Mean was high for the total score slope of change (SRM = 1.10), though higher in PSP (SRM = 1.25) than in MSA (SRM = 1.0), indicating a more rapid progression of PSP. The slope of change was constant with increasing disease severity demonstrating good linearity of the scale throughout disease stages. Although MSA and PSP differed quantitatively on the total score at entry and on rate of progression, the relative contribution of clinical dimensions to overall severity and progression was similar. Conclusions The NNIPPS-PPS has suitable validity, is reliable and sensitive, and therefore is appropriate for use in clinical studies with PSP or MSA. Trial Registration ClinicalTrials.gov NCT00211224 PMID:21829612

  9. A comparison of the reliability of the trochanteric prominence angle test and the alternative method in healthy subjects.

    PubMed

    Yoon, Tae-Lim; Park, Kyung-Mi; Choi, Sil-Ah; Lee, Ji-Hyun; Jeong, Hyo-Jung; Cynn, Heon-Seock

    2014-04-01

    A wide range of intra- and inter-rater reliabilities of the trochanteric prominence angle test (TPAT) has been reported. We introduced the transcondylar angle test (TCAT) as an alternative to the TPAT and using a smartphone as a reliable measurement tool for femoral neck anteversion (FNA) measurement. The reliabilities of the TPAT and the TCAT, the reliability of using a smartphone as a clinical measurement tool, and the correlation between the difference value of medial knee joint space (KJS) between rest and tested positions and the difference value between the TPAT and TCAT were assessed. Two physical therapists independently determined the reliabilities of the TPAT with a digital inclinometer, the TCAT with a digital inclinometer, and the TCAT with a smartphone in 19 hips of 10 healthy subjects (5 male and 5 female, 22.2 ± 1.69 years). The medial KJS in rest and the tested position were assessed using a sonography. The intra-class correlation coefficients (ICC) for the intra-rater reliabilities of TPAT with a digital inclinometer (ICC = 0.92), TCAT with a digital inclinometer (ICC = 0.94) and a smartphone (ICC = 0.95) in both testers were substantial. The inter-rater reliability of TPAT with a digital inclinometer was fair (ICC = 0.48) while TCAT with a digital inclinometer (ICC = 0.89) and a smartphone (ICC = 0.85) were substantial. The correlation between the difference value of medial KJS between rest and tested positions and the difference value between TPAT and TCAT was low and statistically non-significant (r = 0.114; p = 0.325). The TCAT would be more reliable than the TPAT in inter-rater test. Using a smartphone is a clinically comparable measuring tool to a digital inclinometer. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. The Use of an Intra-Articular Depth Guide in the Measurement of Partial Thickness Rotator Cuff Tears

    PubMed Central

    Carroll, Michael J.; More, Kristie D.; Sohmer, Stephen; Nelson, Atiba A.; Sciore, Paul; Boorman, Richard; Hollinshead, Robert; Lo, Ian K. Y.

    2013-01-01

    Purpose. The purpose of this study was to compare the accuracy of the conventional method for determining the percentage of partial thickness rotator cuff tears to a method using an intra-articular depth guide. The clinical utility of the intra-articular depth guide was also examined. Methods. Partial rotator cuff tears were created in cadaveric shoulders. Exposed footprint, total tendon thickness, and percentage of tendon thickness torn were determined using both techniques. The results from the conventional and intra-articular depth guide methods were correlated with the true anatomic measurements. Thirty-two patients were evaluated in the clinical study. Results. Estimates of total tendon thickness (r = 0.41, P = 0.31) or percentage of thickness tears (r = 0.67, P = 0.07) using the conventional method did not correlate well with true tendon thickness. Using the intra-articular depth guide, estimates of exposed footprint (r = 0.92, P = 0.001), total tendon thickness (r = 0.96, P = 0.0001), and percentage of tendon thickness torn (r = 0.88, P = 0.004) correlated with true anatomic measurements. Seven of 32 patients had their treatment plan altered based on the measurements made by the intra-articular depth guide. Conclusions. The intra-articular depth guide appeared to better correlate with true anatomic measurements. It may be useful during the evaluation and development of treatment plans for partial thickness articular surface rotator cuff tears. PMID:23533789

  11. Is laser speckle contrast analysis (LASCA) the new kid on the block in systemic sclerosis? A systematic literature review and pilot study to evaluate reliability of LASCA to measure peripheral blood perfusion in scleroderma patients.

    PubMed

    Cutolo, Maurizio; Vanhaecke, Amber; Ruaro, Barbara; Deschepper, Ellen; Ickinger, Claudia; Melsens, Karin; Piette, Yves; Trombetta, Amelia Chiara; De Keyser, Filip; Smith, Vanessa

    2018-06-06

    A reliable tool to evaluate flow is paramount in systemic sclerosis (SSc). We describe herein on the one hand a systematic literature review on the reliability of laser speckle contrast analysis (LASCA) to measure the peripheral blood perfusion (PBP) in SSc and perform an additional pilot study, investigating the intra- and inter-rater reliability of LASCA. A systematic search was performed in 3 electronic databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In the pilot study, 30 SSc patients and 30 healthy subjects (HS) underwent LASCA assessment. Intra-rater reliability was assessed by having a first anchor rater performing the measurements at 2 time-points and inter-rater reliability by having the anchor rater and a team of second raters performing the measurements in 15 SSc and 30 HS. The measurements were repeated with a second anchor rater in the other 15 SSc patients, as external validation. Only 1 of the 14 records of interest identified through the systematic search was included in the final analysis. In the additional pilot study: intra-class correlation coefficient (ICC) for intra-rater reliability of the first anchor rater was 0.95 in SSc and 0.93 in HS, the ICC for inter-rater reliability was 0.97 in SSc and 0.93 in HS. Intra- and inter-rater reliability of the second anchor rater was 0.78 and 0.87. The identified literature regarding the reliability of LASCA measurements reports good to excellent inter-rater agreement. This very pilot study could confirm the reliability of LASCA measurements with good to excellent inter-rater agreement and found additionally good to excellent intra-rater reliability. Furthermore, similar results were found in the external validation. Copyright © 2018. Published by Elsevier B.V.

  12. Measuring the quality of life in mild to very severe dementia: testing the inter-rater and intra-rater reliability of the German version of the QUALIDEM.

    PubMed

    Dichter, Martin Nikolaus; Schwab, Christian G G; Meyer, Gabriele; Bartholomeyczik, Sabine; Dortmann, Olga; Halek, Margareta

    2014-05-01

    Quality of life (Qol) is an increasingly used outcome measure in dementia research. The QUALIDEM is a dementia-specific and proxy-rated Qol instrument. We aimed to determine the inter-rater and intra-rater reliability in residents with dementia in German nursing homes. The QUALIDEM consists of nine subscales that were applied to a sample of 108 people with mild to severe dementia and six consecutive subscales that were applied to a sample of 53 people with very severe dementia. The proxy raters were 49 registered nurses and nursing assistants. Inter-rater and intra-rater reliability scores were calculated on the subscale and item level. None of the QUALIDEM subscales showed strong inter-rater reliability based on the single-measure Intra-Class Correlation Coefficient (ICC) for absolute agreement ≥ 0.70. Based on the average-measure ICC for four raters, eight subscales for people with mild to severe dementia (care relationship, positive affect, negative affect, restless tense behavior, social relations, social isolation, feeling at home and having something to do) and five subscales for very severe dementia (care relationship, negative affect, restless tense behavior, social relations and social isolation) yielded a strong inter-rater agreement (ICC: 0.72-0.86). All of the QUALIDEM subscales, regardless of dementia severity, showed strong intra-rater agreement. The ICC values ranged between 0.70 and 0.79 for people with mild to severe dementia and between 0.75 and 0.87 for people with very severe dementia. This study demonstrated insufficient inter-rater reliability and sufficient intra-rater reliability for all subscales of both versions of the German QUALIDEM. The degree of inter-rater reliability can be improved by collaborative Qol rating by more than one nurse. The development of a measurement manual with accurate item definitions and a standardized education program for proxy raters is recommended.

  13. Psychometric viability of measures of functional performance commonly used for people with dementia: a systematic review of measurement properties.

    PubMed

    Fox, Benjamin; Henwood, Timothy; Keogh, Justin; Neville, Christine

    2016-08-01

    Confidence in findings can only be drawn from measurement tools that have sound psychometric properties for the population with which they are used. Within a dementia specific population, measures of physical function have been poorly justified in exercise intervention studies, with justification of measures based on validity or reliability studies from dissimilar clinical populations, such as people with bronchitis or healthy older adults without dementia. To review the reliability and validity of quantitative measures of pre-identified physical function, as commonly used within exercise intervention literature for adults with dementia. Participants were adults, aged 65 years and older, with a confirmed medical diagnosis of dementia. n/a Desired studies were observational and cross-sectional and that assessed measures from a pre-identified list of measures of physical function. Studies that assessed the psychometric constructs of reliability and validity were targeted. COSMIN taxology was used to define reliability and validity. This included, but were not limited to, Intra-Class Correlations, Kappa, Cronbach's Alpha, Chi Squared, Standard Error of Measurement, Minimal Detectable Change and Limits of Agreement. Published material was sourced from the following four databases: MEDLINE, EMBASE, CINAHL and ISI Web of Science. Grey literature was searched for using ALOIS, Google Scholar and ProQuest. The COSMIN checklist was used to assess methodological quality of included studies. Assessment was completed by two reviewers independently. Reliability and validity data was extracted from included studies using standardized Joanna Briggs Institute data collection forms. Extraction was completed by two reviewers. A narrative synthesis of measurement properties of the tools used to measure physical function was performed. Quantitative meta-analysis was conducted for Intra-Class Correlation Coefficients only. With respect to relative reliability, studies reporting assessed measures had intraclass correlation coefficients greater than 0.71, indicating their suitability for use at a group level. However, a consistent finding among studies that included assessment of absolute reliability was that intra individual variation was too large for meaningful measurement of individuals. This was indicated by large Minimal Detectable Change (MDC) scores. Walk Speed has the smallest reported Mimimal Detectable Change score at 0.11m/s. This represented a change of 35% before statistical variation could be eliminated as the cause for this change. All measures had large MDC values. Walk Speed had the smallest MDC values at 0.11m/s, which represented a necessary change of 35%. Only a limited number of studies assessed the validity of measures. This supports the use of these measures in a very narrow selection of circumstances (see Summary of Findings). In summary, measures have shown appropriate levels of relative reliability. This supports their use at the group level. However, large levels of intra-individual variation undermine their applicability at the individual level. Limited studies of validity were available to this review, which limits a conclusion on whether measures are valid for people with dementia.

  14. Black Boundary Lines: Race, Class and Gender among Black Undergraduate Students

    ERIC Educational Resources Information Center

    Morales, Erica Marie

    2012-01-01

    Intra-group differences among Black undergraduate students remain understudied. To gain a more nuanced understanding of Black student life, we must examine how other social locations, like gender and class, connect to the racialized experiences of Black students. This dissertation argues that for Black students, class and gender, along with race,…

  15. Reliability and validity of the range of motion scale (ROMS) in patients with abnormal postures.

    PubMed

    van Rooijen, Diana E; Lalli, Stefania; Marinus, Johan; Maihöfner, Christian; McCabe, Candida S; Munts, Alex G; van der Plas, Anton A; Tijssen, Marina A J; van de Warrenburg, Bart P; Albanese, Alberto; van Hilten, Jacobus J

    2015-03-01

    Sustained abnormal postures (i.e., fixed dystonia) are the most frequently reported motor abnormalities in complex regional pain syndrome (CRPS), but these symptoms may also develop after peripheral trauma without CRPS. Currently, there is no valid and reliable measurement instrument available to measure the severity and distribution of these postures. The range of motion scale (ROMS) was therefore developed to assess the severity based on the possible active range of motion of all joints (arms, legs, trunk, and neck), and the present study evaluates its reliability and validity. Inter- and intra-rater reliability of the ROMS was determined in 16 patients with abnormal sustained postures, who were videotaped following a standard video protocol in a university hospital. The recordings were rated by a panel of international experts. In addition, 30 patients were clinically tested with both the Burke-Fahn-Marsden (BFM) scale as well as the ROMS to assess construct validity. Inter-rater reliability for total ROMS scores showed an intra-class correlation coefficient (ICC) of 0.85. The majority of the scores for the separate joints (13 out of 18) demonstrated an almost perfect agreement with ICCs ranging from 0.81 to 0.94; of the other items, one showed fair, one moderate, and three substantial agreement. The ICCs for the intra-rater reliability ranged from moderate to almost perfect (0.68-0.98). Spearman's correlation coefficients between corresponding body areas as measured with the ROMS or BFM were all above 0.82. The ROMS is a reliable and valid instrument to evaluate the severity and distribution of sustained abnormal postures. Wiley Periodicals, Inc.

  16. Stability and reproducibility of proteomic profiles measured with an aptamer-based platform.

    PubMed

    Kim, Claire H; Tworoger, Shelley S; Stampfer, Meir J; Dillon, Simon T; Gu, Xuesong; Sawyer, Sherilyn J; Chan, Andrew T; Libermann, Towia A; Eliassen, A Heather

    2018-05-30

    The feasibility of SOMAscan, a multiplex, high sensitivity proteomics platform, for use in studies using archived plasma samples has not yet been assessed. We quantified 1,305 proteins from plasma samples donated by 16 Nurses' Health Study (NHS) participants, 40 NHSII participants, and 12 local volunteers. We assessed assay reproducibility using coefficients of variation (CV) from duplicate samples and intra-class correlation coefficients (ICC) and Spearman correlation coefficients (r) of samples processed (i.e., centrifuged and aliquoted into separate components) immediately, 24, and 48 hours after collection, as well as those of samples collected from the same individuals 1 year apart. CVs were <20% for 99% of proteins overall and <10% for 92% of proteins in heparin samples compared to 66% for EDTA samples. We observed ICC or Spearman r (comparing immediate vs. 24-hour delayed processing) ≥0.75 for 61% of proteins, with some variation by anticoagulant (56% for heparin and 70% for EDTA) and protein class (ranging from 49% among kinases to 83% among hormones). Within-person stability over 1 year was good (ICC or Spearman r ≥ 0.4) for 91% of proteins. These results demonstrate the feasibility of SOMAscan for analyses of archived plasma samples.

  17. Questions of Degree? Middle-Class Rejection of Higher Education and Intra-Class Differences in Educational Decision-Making

    ERIC Educational Resources Information Center

    Morrison, Andrew

    2011-01-01

    This article is an analysis of middle-class rejection of higher education. The author uses accounts of the educational decision-making of three female students, all identified to be from broadly middle-class backgrounds, from within full-time vocational further education in the United Kingdom, as a means to consider two issues. First, the author…

  18. The development and validation of a custom built device for assessing frontal knee joint laxity.

    PubMed

    Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos

    2017-12-01

    This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Nanoengineered particles for enhanced intra-articular retention and delivery of proteins.

    PubMed

    Singh, Ankur; Agarwal, Rachit; Diaz-Ruiz, Carlos A; Willett, Nick J; Wang, Peiyi; Lee, L Andrew; Wang, Qian; Guldberg, Robert E; García, Andrés J

    2014-10-01

    Localized intra-articular delivery of anti-inflammatory proteins can reduce inflammation in osteoarthritis but poses a challenge because of raid clearance within few hours of injection. A new class of polymer is developed that forms self-assembled nanoparticles ranging from 300 to 900 nm and demonstrates particle size dependent prolonged retention in intra-articular joint spaces compared to bolus protein over a period of 14 d. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Comparison of caries detection methods using varying numbers of intra-oral digital photographs with visual examination for epidemiology in children

    PubMed Central

    2013-01-01

    Background This was a method comparison study. The aim of study was to compare caries information obtained from a full mouth visual examination using the method developed by the British Association for the Study of Community Dentistry (BASCD) for epidemiological surveys with caries data obtained from eight, six and four intra-oral digital photographs of index teeth in two groups of children aged 5 years and 10/11 years. Methods Five trained and calibrated examiners visually examined the whole mouth of 240 5-year-olds and 250 10-/11-year-olds using the BASCD method. The children also had intra-oral digital photographs taken of index teeth. The same 5 examiners assessed the intra-oral digital photographs (in groups of 8, 6 and 4 intra-oral photographs) for caries using the BASCD criteria; dmft/DMFT were used to compute Weighted Kappa Statistic as a measure of intra-examiner reliability and intra-class correlation coefficients as a measure of inter-examiner reliability for each method. A method comparison analysis was performed to determine the 95% limits of agreement for all five examiners, comparing the visual examination method with the photographic assessment method using 8, 6 and 4 intra-oral photographs. Results The intra-rater reliability for the visual examinations ranged from 0.81 to 0.94 in the 5-year-olds and 0.90 to 0.97 in the 10-/11-year-olds. Those for the photographic assessments in the 5-year-olds were for 8 intra-oral photographs, 0.86 to 0.94, for 6 intra-oral photographs, 0.85 to 0.98 and for 4 intra-oral photographs, 0.80 to 0.96; for the 10-/11-year-olds were for 8 intra-oral photographs 0.84 to 1.00, for 6 intra-oral photographs 0.82 to 1.00 and for 4 intra-oral photographs 0.72 to 0.98. The 95% limits of agreement were −1.997 to 1.967, -2.375 to 2.735 and −2.250 to 2.921 respectively for the 5-year-olds and −2.614 to 2.027, -2.179 to 3.887 and −2.594 to 2.163 respectively for the 10-/11-year-olds. Conclusions The photographic assessment method, particularly assessment of 8 intra-oral digital photographs is comparable to the visual examination method in the primary dentition. With the additional benefits of archiving, remote scoring, allowing multiple scorers to score images and enabling longitudinal analysis, the photographic assessment method may be used as an alternative caries detection method in the primary dentition in situations where the visual examination method may not be applicable such as when examiner blinding is required and in practice based randomised controlled trials (RCTs). PMID:23312001

  1. Agreement among healthcare professionals in ten European countries in diagnosing case-vignettes of surgical-site infections.

    PubMed

    Birgand, Gabriel; Lepelletier, Didier; Baron, Gabriel; Barrett, Steve; Breier, Ann-Christin; Buke, Cagri; Markovic-Denic, Ljiljana; Gastmeier, Petra; Kluytmans, Jan; Lyytikainen, Outi; Sheridan, Elizabeth; Szilagyi, Emese; Tacconelli, Evelina; Troillet, Nicolas; Ravaud, Philippe; Lucet, Jean-Christophe

    2013-01-01

    Although surgical-site infection (SSI) rates are advocated as a major evaluation criterion, the reproducibility of SSI diagnosis is unknown. We assessed agreement in diagnosing SSI among specialists involved in SSI surveillance in Europe. Twelve case-vignettes based on suspected SSI were submitted to 100 infection-control physicians (ICPs) and 86 surgeons in 10 European countries. Each participant scored eight randomly-assigned case-vignettes on a secure online relational database. The intra-class correlation coefficient (ICC) was used to assess agreement for SSI diagnosis on a 7-point Likert scale and the kappa coefficient to assess agreement for SSI depth on a three-point scale. Intra-specialty agreement for SSI diagnosis ranged across countries and specialties from 0.00 (95%CI, 0.00-0.35) to 0.65 (0.45-0.82). Inter-specialty agreement varied from 0.04 (0.00-0.62) in to 0.55 (0.37-0.74) in Germany. For all countries pooled, intra-specialty agreement was poor for surgeons (0.24, 0.14-0.42) and good for ICPs (0.41, 0.28-0.61). Reading SSI definitions improved agreement among ICPs (0.57) but not surgeons (0.09). Intra-specialty agreement for SSI depth ranged across countries and specialties from 0.05 (0.00-0.10) to 0.50 (0.45-0.55) and was not improved by reading SSI definition. Among ICPs and surgeons evaluating case-vignettes of suspected SSI, considerable disagreement occurred regarding the diagnosis, with variations across specialties and countries.

  2. Agreement among Healthcare Professionals in Ten European Countries in Diagnosing Case-Vignettes of Surgical-Site Infections

    PubMed Central

    Birgand, Gabriel; Lepelletier, Didier; Baron, Gabriel; Barrett, Steve; Breier, Ann-Christin; Buke, Cagri; Markovic-Denic, Ljiljana; Gastmeier, Petra; Kluytmans, Jan; Lyytikainen, Outi; Sheridan, Elizabeth; Szilagyi, Emese; Tacconelli, Evelina; Troillet, Nicolas; Ravaud, Philippe; Lucet, Jean-Christophe

    2013-01-01

    Objective Although surgical-site infection (SSI) rates are advocated as a major evaluation criterion, the reproducibility of SSI diagnosis is unknown. We assessed agreement in diagnosing SSI among specialists involved in SSI surveillance in Europe. Methods Twelve case-vignettes based on suspected SSI were submitted to 100 infection-control physicians (ICPs) and 86 surgeons in 10 European countries. Each participant scored eight randomly-assigned case-vignettes on a secure online relational database. The intra-class correlation coefficient (ICC) was used to assess agreement for SSI diagnosis on a 7-point Likert scale and the kappa coefficient to assess agreement for SSI depth on a three-point scale. Results Intra-specialty agreement for SSI diagnosis ranged across countries and specialties from 0.00 (95%CI, 0.00–0.35) to 0.65 (0.45–0.82). Inter-specialty agreement varied from 0.04 (0.00–0.62) in to 0.55 (0.37–0.74) in Germany. For all countries pooled, intra-specialty agreement was poor for surgeons (0.24, 0.14–0.42) and good for ICPs (0.41, 0.28–0.61). Reading SSI definitions improved agreement among ICPs (0.57) but not surgeons (0.09). Intra-specialty agreement for SSI depth ranged across countries and specialties from 0.05 (0.00–0.10) to 0.50 (0.45–0.55) and was not improved by reading SSI definition. Conclusion Among ICPs and surgeons evaluating case-vignettes of suspected SSI, considerable disagreement occurred regarding the diagnosis, with variations across specialties and countries. PMID:23874690

  3. High-resolution dental magnetic resonance imaging for planning palatal graft surgery-a clinical pilot study.

    PubMed

    Hilgenfeld, Tim; Kästel, Thorsten; Heil, Alexander; Rammelsberg, Peter; Heiland, Sabine; Bendszus, Martin; Schwindling, Franz Sebastian

    2018-04-01

    To evaluate whether high-resolution, non-contrast-enhanced dental magnetic resonance imaging (MRI) can be used for accurate determination of palatal masticatory mucosa thickness (PMMT) and to locate the greater palatal artery (GPA). In five volunteers (four males, one female; mean age 30.2 ± 0.4 years), two independent raters measured PMMT by use of dental MRI in 180 positions. For comparison, clinical bone sounding was performed. The GPA was identified in time-of-flight (TOF) angiography and MSVAT-SPACE-prototype sequence. Intra- and inter-observer agreement for MRI measurements, agreement between MRI and bone sounding were analysed by intra-class correlation coefficient (ICC) and Cohen's kappa (κ). Reliability of dental MRI measurements was high (intra-observer-ICC 0.962; inter-observer ICC 0.959). Agreement of MRI measurements with bone sounding was moderate (ICC 0.744), and the GPA could be identified in 60% of measurement points using the TOF-angiography alone and in 85% with additional information of the MSVAT-SPACE. Good intra-observer agreement was observed for GPA identification (κ: 0.778). Palatal masticatory mucosa thickness measured by high-resolution, non-contrast enhanced dental MRI is comparable with that obtained by bone sounding. Dental MRI enables reliable, non-invasive and radiation-free planning of palatal tissue harvesting and can also be used for location of the GPA at 85% of measurement points, which might help reduce complications during surgery. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Reliability of the measures of weight-bearing distribution obtained during quiet stance by digital scales in subjects with and without hemiparesis.

    PubMed

    de Araujo-Barbosa, Paulo Henrique Ferreira; de Menezes, Lidiane Teles; Costa, Abraão Souza; Couto Paz, Clarissa Cardoso Dos Santos; Fachin-Martins, Emerson

    2015-05-01

    Described as an alternative way of assessing weight-bearing asymmetries, the measures obtained from digital scales have been used as an index to classify weight-bearing distribution. This study aimed to describe the intra-test and the test/retest reliability of measures in subjects with and without hemiparesis during quiet stance. The percentage of body weight borne by one limb was calculated for a sample of subjects with hemiparesis and for a control group that was matched by gender and age. A two-way analysis of variance was used to verify the intra-test reliability. This analysis was calculated using the differences between the averages of the measures obtained during single, double or triple trials. The intra-class correlation coefficient (ICC) was utilized and data plotted using the Bland-Altman method. The intra-test analysis showed significant differences, only observed in the hemiparesis group, between the measures obtained by single and triple trials. Excellent and moderate ICC values (0.69-0.84) between test and retest were observed in the hemiparesis group, while for control groups ICC values (0.41-0.74) were classified as moderate, progressing from almost poor for measures obtained by a single trial to almost excellent for those obtained by triple trials. In conclusion, good reliability ranging from moderate to excellent classifications was found for participants with and without hemiparesis. Moreover, an improvement of the repeatability was observed with fewer trials for participants with hemiparesis, and with more trials for participants without hemiparesis.

  5. Intra- and inter-examination repeatability of magnetic resonance spectroscopy, magnitude-based MRI, and complex-based MRI for estimation of hepatic proton density fat fraction in overweight and obese children and adults.

    PubMed

    Tyagi, Avishkar; Yeganeh, Omid; Levin, Yakir; Hooker, Jonathan C; Hamilton, Gavin C; Wolfson, Tanya; Gamst, Anthony; Zand, Amir K; Heba, Elhamy; Loomba, Rohit; Schwimmer, Jeffrey; Middleton, Michael S; Sirlin, Claude B

    2015-10-01

    Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was <0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R (2), respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change >1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements.

  6. Intra- and inter-examination repeatability of magnetic resonance spectroscopy, magnitude-based MRI, and complex-based MRI for estimation of hepatic proton density fat fraction in overweight and obese children and adults

    PubMed Central

    Tyagi, Avishkar; Yeganeh, Omid; Levin, Yakir; Hooker, Jonathan C.; Hamilton, Gavin C.; Wolfson, Tanya; Gamst, Anthony; Zand, Amir K.; Heba, Elhamy; Loomba, Rohit; Schwimmer, Jeffrey; Middleton, Michael S.; Sirlin, Claude B.

    2016-01-01

    Purpose Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Methods Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. Results For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was <0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R2, respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. Conclusion MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change >1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements. PMID:26350282

  7. Intra-articular findings in symptomatic minor instability of the lateral elbow (SMILE).

    PubMed

    Arrigoni, Paolo; Cucchi, Davide; D'Ambrosi, Riccardo; Butt, Usman; Safran, Marc R; Denard, Patrick; Randelli, Pietro

    2017-07-01

    Lateral epicondylitis is generally considered an extra-articular condition. The role of minor instability in the aetiology of lateral elbow pain has rarely been considered. The aim of this study was to evaluate the correlation of lateral ligamentous laxity with aspects of intra-articular lateral elbow pathology and investigate the role of minor instability in lateral elbow pain. Thirty-five consecutive patients aged between 20 and 60 years with recalcitrant lateral epicondylitis who had failed conservative therapy and had no previous trauma or overt instability, were included. The presence of three signs of lateral ligamentous patholaxity and five intra-articular findings were documented during arthroscopy. The relative incidence of each of these was calculated, and the correlation between patholaxity and intra-articular pathology was evaluated. At least one sign of lateral ligamentous laxity was observed in 48.6% of the studied cohort, and 85.7% demonstrated at least one intra-articular abnormal finding. Radial head ballottement was the most common sign of patholaxity (42.9%). Synovitis was the most common intra-articular aspect of pathology (77.1%), followed by lateral capitellar chondropathy (40.0%). A significant correlation was found between the presence of lateral ligamentous patholaxity signs and capitellar chondropathy (p = 0.0409), as well as anteromedial synovitis (p = 0.0408). Almost one half of patients suffering from recalcitrant lateral epicondylitis display signs of lateral ligamentous patholaxity, and over 85% demonstrate at least one intra-articular abnormality. The most frequent intra-articular findings are synovitis and lateral capitellar chondropathy, which correlate significantly with the presence of lateral ligamentous patholaxity. The fact that several patients demonstrated multiple intra-articular findings in relation to laxity provides support to a sequence of pathologic changes that may result from a symptomatic minor instability of the lateral elbow (SMILE) condition. III.

  8. Cross-parent reliability in rating ASD markers in infants.

    PubMed

    Ben-Sasson, Ayelet; Amit-Ben-Simhon, Hemda; Meyer, Sonya

    2015-06-01

    To investigate the congruence and discrepancies between mother and father reports of early autism spectrum disorders (ASD) markers. Mothers (n = 80) and fathers (n = 78) of 12-month-old infants (55% boys) completed the first year inventory (FYI), an ASD norm-referenced screening questionnaire. Mothers also completed the Infant Toddler Social Emotional Assessment (ITSEA). There were significant and moderate intra-class correlations between mother and father reports for most FYI factors. Fathers' median FYI social-communication domain score was almost twice that of mothers. Mann-Whitney tests indicated that fathers rated their child significantly higher than mothers on the four FYI social-communication factors and on the sensory processing factor. Linear weighted kappa analyses indicated poor agreement on gaze-related and reactivity FYI items. FYI social-communication and sensory-regulatory factors showed significant correlations with corresponding ITSEA scores. Social-communication markers pose a greater challenge for consistent report across parents than sensory-regulatory markers.

  9. Reliability of assessment of upper trapezius morphology, its mechanical properties and blood flow in female patients with myofascial pain syndrome using ultrasonography.

    PubMed

    Adigozali, Hakimeh; Shadmehr, Azadeh; Ebrahimi, Esmail; Rezasoltani, Asghar; Naderi, Farrokh

    2017-01-01

    In the present study, the intra-rater reliability of upper trapezius morphology, its mechanical properties and intramuscular blood circulation in females with myofascial pain syndrome were assessed using ultrasonography. A total of 37 patients (31.05 ± 10 years old) participated in this study. Ultrasonography producer was set up in three stages: a) Gray-scale: to measure muscle thickness, size and area of trigger points; b) Ultrasound elastography: to measure muscle stiffness; and c) Doppler imaging: to assess blood flow indices. According to data analysis, all variables, except End Diastolic Velocity (EDV), had excellent reliability (>0.806). Intra-class Correlation Coefficient (ICC) for EDV was 0.738, which was considered a poor to good reliability. The results of this study introduced a reliable method for developing details of upper trapezius features using muscular ultrasonography in female patients. These variables could be used for objective examination and provide guidelines for treatment plans in clinical settings. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Reproducibility of electronic tooth colour measurements.

    PubMed

    Ratzmann, Anja; Klinke, Thomas; Schwahn, Christian; Treichel, Anja; Gedrange, Tomasz

    2008-10-01

    Clinical methods of investigation, such as tooth colour determination, should be simple, quick and reproducible. The determination of tooth colours usually relies upon manual comparison of a patient's tooth colour with a colour ring. After some days, however, measurement results frequently lack unequivocal reproducibility. This study aimed to examine an electronic method for reliable colour measurement. The colours of the teeth 14 to 24 were determined by three different examiners in 10 subjects using the colour measuring device Shade Inspector. In total, 12 measurements per tooth were taken. Two measurement time points were scheduled to be taken, namely at study onset (T(1)) and after 6 months (T(2)). At either time point, two measurement series per subject were taken by the different examiners at 2-week intervals. The inter-examiner and intra-examiner agreement of the measurement results was assessed. The concordance for lightness and colour intensity (saturation) was represented by the intra-class correlation coefficient. The categorical variable colour shade (hue) was assessed using the kappa statistic. The study results show that tooth colour can be measured independently of the examiner. Good agreement was found between the examiners.

  11. Assessing self-reported disability in a low-literate population with chronic low back pain: cross-cultural adaptation and psychometric testing of Igbo Roland Morris disability questionnaire.

    PubMed

    Igwesi-Chidobe, Chinonso N; Obiekwe, Chinwe; Sorinola, Isaac O; Godfrey, Emma L

    2017-12-14

    Cross-culturally adapt and validate the Igbo Roland Morris Disability Questionnaire. Cross-cultural adaptation, test-retest, and cross-sectional psychometric testing. Roland Morris Disability Questionnaire was forward and back translated by clinical/non-clinical translators. An expert committee appraised the translations. Twelve participants with chronic low back pain pre-tested the measure in a rural Nigerian community. Internal consistency using Cronbach's alpha; test-retest reliability using intra-class correlation coefficient and Bland-Altman plot; and minimal detectable change were investigated in a convenient sample of 50 people with chronic low back pain in rural and urban Nigeria. Pearson's correlation analyses using the eleven-point box scale and back performance scale, and exploratory factor analysis were used to examine construct validity in a random sample of 200 adults with chronic low back pain in rural Nigeria. Ceiling and floor effects were investigated in the two samples. Modifications gave the option of interviewer-administration and reflected Nigerian social context. The measure had excellent internal consistency (α = 0.91) and intraclass correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity, and a predominant uni-dimensional structure, with no ceiling or floor effects. Igbo Roland Morris Disability Questionnaire is a valid and reliable measure of pain-related disability. Implications for rehabilitation Low back pain is the leading cause of years lived with disability worldwide, and is particularly prevalent in rural Nigeria, but there are no self-report measures to assess its impact due to low literacy rates. This study describes the cross-cultural adaptation and validation of a core self-report back pain specific disability measure in a low-literate Nigerian population. The Igbo Roland Morris Disability Questionnaire is a reliable and valid measure of self-reported disability in Igbo populations as indicated by excellent internal consistency (α = 0.91) and intra-class correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity that supports a pain-related disability construct, a predominant one factor structure with no ceiling or floor effects. The measure will be useful for researchers and clinicians examining the factors associated with low back pain disability or the effects of interventions on low back pain disability in this culture. This measure will support global health initiatives concurrently involving people from several cultures or countries, and may inform cross-cultural disability research in other populations.

  12. Validity and reliability of a Nigerian-Yoruba version of the stroke-specific quality of life scale 2.0.

    PubMed

    Odetunde, Marufat Oluyemisi; Akinpelu, Aderonke Omobonike; Odole, Adesola Christiana

    2017-10-19

    Psychometric evidence is necessary to establish scientific integrity and clinical usefulness of translations and cultural adaptations of the Stroke-Specific Quality of Life (SS-QoL) scale. However, the limited evidence on psychometrics of Yoruba version of SS-QoL 2.0 (SS-QoL(Y)) is a significant shortcoming. This study assessed the test-retest reliability, internal consistency, convergent, divergent, discriminant and known-group validity of the SS-QoL(Y). Yoruba version of the WHOQoL-BREF was used to test the convergent and divergent validity of the SS-QoL(Y) among 100 consenting stroke survivors. The WHOQoL-BREF and SS-QoL(Y) was administered randomly in order to eliminate bias. The test-retest reliability of the SS-QoL(Y) was carried out among 68 of the respondents within an interval of 7 days. All respondents were purposively recruited from selected secondary and tertiary health facilities in South-west Nigeria. Data were analysed using descriptive statistics of mean and standard deviation, and inferential statistics of Spearman correlation, Cronbach's alpha, Intra-class Correlation Coefficient (ICC), Independent t-test and One-way ANOVA. Alpha level was set at p < 0.05. The physical health, psychological health, social relationship and environment domains on WHOQoL-BREF with correlation coefficient that ranged from 0.214 to 0.360 showed significant correlation with similar domains on SS-QoL(Y). Dissimilar domains between the two scales had r values from 0.035 to 0.366. Discriminant validity of SS-QoL(Y) showed that items' r value ranged from 0.711 to 0.920 with their hypothesized domains. The scale demonstrated moderate to strong test-retest reliability with Intra-class correlation coefficient (ICC) for the domains and overall scores (r = 0.47 to 0.81) and moderate to high internal consistency (Cronbach's alpha =0.61 to 0.82) for domains scores. These correlations were also significant for the domains and overall scores (p < 0.05). There were no significant differences across different age groups or gender for the domains or overall scores of SS-QoL(Y). Discriminant and known-group validity, test-retest reliability and internal consistency of the Yoruba version of the Stroke Specific Quality of Life 2.0 are adequate while the convergent and divergent validity are low but acceptable. The SS-QoL(Y) is recommended for assessing health-related quality of life among Yoruba stroke survivors.

  13. Computing Inter-Rater Reliability for Observational Data: An Overview and Tutorial

    PubMed Central

    Hallgren, Kevin A.

    2012-01-01

    Many research designs require the assessment of inter-rater reliability (IRR) to demonstrate consistency among observational ratings provided by multiple coders. However, many studies use incorrect statistical procedures, fail to fully report the information necessary to interpret their results, or do not address how IRR affects the power of their subsequent analyses for hypothesis testing. This paper provides an overview of methodological issues related to the assessment of IRR with a focus on study design, selection of appropriate statistics, and the computation, interpretation, and reporting of some commonly-used IRR statistics. Computational examples include SPSS and R syntax for computing Cohen’s kappa and intra-class correlations to assess IRR. PMID:22833776

  14. Teaching to the Golem: A Pedagogical Intra-Action

    ERIC Educational Resources Information Center

    Tanner, Samuel Jaye

    2017-01-01

    This article considers the pedagogical nature of an intra-action involving the author, his high school student's final project in an English class (a golem), and his school administrators. The author relies on narrative scholarship to both tell and interpret a story of his experience as a high school English and drama teacher, to illustrate the…

  15. The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers

    PubMed Central

    Omari, Taher I.; Savilampi, Johanna; Kokkinn, Karmen; Schar, Mistyka; Lamvik, Kristin; Doeltgen, Sebastian; Cock, Charles

    2016-01-01

    Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. PMID:27190520

  16. Quantification of intra-tumour cell proliferation heterogeneity using imaging descriptors of 18F fluorothymidine-positron emission tomography

    NASA Astrophysics Data System (ADS)

    Willaime, J. M. Y.; Turkheimer, F. E.; Kenny, L. M.; Aboagye, E. O.

    2013-01-01

    Intra-tumour heterogeneity is a characteristic shared by all cancers. We explored the use of texture variables derived from images of [18F]fluorothymidine-positron emission tomography (FLT-PET), thus notionally assessing the heterogeneity of proliferation in individual tumours. Our aims were to study the range of textural feature values across tissue types, verify the repeatability of these image descriptors and further, to explore associations with clinical response to chemotherapy in breast cancer patients. The repeatability of 28 textural descriptors was assessed in patients who had two FLT-PET scans prior to therapy using relative differences and the intra-class correlation coefficient (ICC). We tested associations between features at baseline and clinical response measured in 11 patients after three cycles of chemotherapy, and explored changes in FLT-PET at one week after the start of therapy. A subset of eight features was characterized by low variations at baseline (<±30%) and high repeatability (0.7 ≤ ICC ≤ 1). The intensity distribution profile suggested fewer highly proliferating cells in lesions of non-responders compared to responders at baseline. A true increase in CV and homogeneity was measured in four out of six responders one week after the start of therapy. A number of textural features derived from FLT-PET are altered following chemotherapy in breast cancer, and should be evaluated in larger clinical trials for clinical relevance.

  17. Spanish version of the Kidney Disease Knowledge Survey (KiKS) in Peru: cross-cultural adaptation and validation.

    PubMed

    Mota-Anaya, Evelin; Yumpo-Cárdenas, Daniel; Alva-Bravo, Edmundo; Wright-Nunes, Julie; Mayta-Tristán, Percy

    2016-08-08

    Chronic kidney disease (CKD) affects 50 million people globally. Several studies show the importance of implementing interventions that enhance patients’ knowledge about their disease. In 2011 the Kidney Disease Knowledge Survey (KiKS) was developed: a questionnaire that assesses the specific knowledge about chronic kidney disease in pre-dialysis patients. To translate to Spanish, culturally adapt and validate the Kidney Disease Knowledge Survey questionnaire in a population of patients with pre-dialysis chronic kidney disease. We carried out a Spanish translation and cross-cultural adaptation of the Kidney Disease Knowledge Survey questionnaire. Subsequently, we determined its validity and reliability. We determined the validity through construct validity; and reliability by evaluating its internal consistency and its intra-observer reliability (test-retest). We found a good internal consistency (Kuder-Richardson = 0.85). The intra-observer reliability was measured by the intra-class correlation coefficient that yielded a value of 0.78 (95% CI: 0.5-1.0). This value indicated a good reproducibility; also, the mean difference of -1.1 test-retest SD 6.0 (p = 0.369) confirms this finding. The translated Spanish version of the Kidney Disease Knowledge Survey is acceptable and equivalent to the original version; it also has a good reliability, validity and reproducibility. Therefore, it can be used in a population of patients with pre-dialysis chronic kidney disease.

  18. Patterns of diet-related practices and prevalence of gastro-esophageal reflux disease.

    PubMed

    Esmaillzadeh, A; Keshteli, A H; Feizi, A; Zaribaf, F; Feinle-Bisset, C; Adibi, P

    2013-10-01

    No studies have evaluated associations between patterns of diet-related practices as determined by latent class analysis (LCA) and gastro-esophageal reflux disease (GERD). We aimed to assess this relationship in a large sample of Iranian adults. In a cross-sectional study in 4763 adults, diet-related practices were assessed in four domains, 'meal pattern', 'eating rate', 'intra-meal fluid intake', and 'meal-to-sleep interval', using a pretested questionnaire. LCA was applied to identify classes of diet-related practices. We defined GERD as the presence of heartburn sometimes, often or always. The prevalence of GERD in the study population was 23.5% (n = 1120). We identified two distinct classes of meal patterns: 'regular' and 'irregular', three classes of eating rates: 'moderate', 'moderate-to-slow', and 'moderate-to-fast', two major classes of fluid ingestion with meals: 'moderate' and 'much intra-meal drinking', and two classes regarding the interval between meals and sleeping: 'short' and 'long meal-to-sleep' interval. After adjustment for potential confounders, subjects with 'irregular meal pattern' had higher odds of GERD compared with subjects with 'regular meal pattern' (OR: 1.21; 1.00-1.46). However, when taking into account BMI, the association disappeared. 'Long meal-to-sleep interval' was inversely associated with GERD compared with 'short meal-to-sleep interval' (OR: 0.73; 95% CI: 0.57-0.95). 'Eating rate' and 'intra-meal fluid intake' were not significantly associated with GERD. Our data suggest certain associations between dietary patterns and GERD. These findings warrant evaluation in prospective studies to establish the potential value of modifications in dietary behaviors for the management of GERD. © 2013 John Wiley & Sons Ltd.

  19. CROSS-CULTURAL ADAPTATION AND VALIDATION OF THE KOREAN VERSION OF THE CUMBERLAND ANKLE INSTABILITY TOOL.

    PubMed

    Ko, Jupil; Rosen, Adam B; Brown, Cathleen N

    2015-12-01

    The Cumberland Ankle Instability Tool (CAIT) is a valid and reliable patient reported outcome used to assess the presence and severity of chronic ankle instability (CAI). The CAIT has been cross-culturally adapted into other languages for use in non-English speaking populations. However, there are no valid questionnaires to assess CAI in individuals who speak Korean. The purpose of this study was to translate, cross-culturally adapt, and validate the CAIT, for use in a Korean-speaking population with CAI. Cross-cultural reliability study. The CAIT was cross-culturally adapted into Korean according to accepted guidelines and renamed the Cumberland Ankle Instability Tool-Korean (CAIT-K). Twenty-three participants (12 males, 11 females) who were bilingual in English and Korean were recruited and completed the original and adapted versions to assess agreement between versions. An additional 168 national level Korean athletes (106 male, 62 females; age = 20.3 ± 1.1 yrs), who participated in ≥ 90 minutes of physical activity per week, completed the final version of the CAIT-K twice within 14 days. Their completed questionnaires were assessed for internal consistency, test-retest reliability, criterion validity, and construct validity. For bilingual participants, intra-class correlation coefficients (ICC2,1) between the CAIT and the CAIT-K for test-retest reliability were 0.95 (SEM=1.83) and 0.96 (SEM=1.50) in right and left limbs, respectively. The Cronbach's alpha coefficients were 0.92 and 0.90 for the CAIT-K in right and left limbs, respectively. For native Korean speakers, the CAIT-K had high internal consistency (Cronbach's α=0.89) and intra-class correlation coefficient (ICC2,1 = 0.94, SEM=1.72), correlation with the physical component score (rho=0.70, p = 0.001) of the Short-Form Health Survey (SF-36), and the Kaiser-Meyer-Olkin score was 0.87. The original CAIT was translated, cross-culturally adapted, and validated from English to Korean. The CAIT-K appears to be valid and reliable and could be useful in assessing the Korean speaking population with CAI.

  20. A comparative study of software programmes for cross-sectional skeletal muscle and adipose tissue measurements on abdominal computed tomography scans of rectal cancer patients.

    PubMed

    van Vugt, Jeroen L A; Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J; Burger, Jacobus W A; Willemsen, Sten P; de Bruin, Ron W F; IJzermans, Jan N M

    2017-04-01

    The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single-slice computed tomography (CT)-based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter-observer, intra-observer, and inter-software correlation are unknown. Therefore, a comparative study was performed. Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross-sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter-software, intra-observer, and inter-observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra-class correlation coefficients (ICCs) and Bland-Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Bland-Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979-1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88-0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra-observer (ICC 0.999-1.000, P < 0.001) and inter-observer (ICC 0.998-0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter-observer and intra-observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. © 2016 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.

  1. Intra- and intergenerational social mobility in relation to height, weight and body mass index in a British national cohort.

    PubMed

    Krzyżanowska, Monika; Mascie-Taylor, C G Nicholas

    2011-09-01

    Using a sample of 2090 father and son pairs, the extent of intra- and inter-generational social mobility (migration between social classes) was examined over a 42-year period in a British cohort in relation to height, weight and body mass index (BMI). The mean height difference between the highest and lowest social class decreased from about 4 cm in the fathers' generation to about 3 cm in the sons' generation, indicating a decline in heterogeneity in height between classes. For fathers downward intra-generational social mobility ranged between 11% and 18% while between 16% and 26% were upwardly mobile; for sons 15% were downwardly mobile and 21% upwardly mobile. On average downwardly mobile fathers were shorter by between 0.1 cm and 0.7 cm while upwardly mobile fathers were taller by, on average, 0.6 cm to 1.7 cm. For sons, the downwardly mobile were on average 0.7 cm shorter and the upwardly mobile 0.8 cm taller. For weight and BMI there were no consistent relationships with intra-generational mobility in either the fathers' or sons' generations. Inter-generationally, between 18% and 19% of sons were downwardly mobile and between 39% and 40% were upwardly mobile; the downwardly mobile were shorter by about 0.9 cm and the upwardly taller by between 0.6 cm and 1.2 cm. Sons with higher BMI were more likely to be inter-generationally downwardly mobile.

  2. Assets as a Socioeconomic Status Index: Categorical Principal Components Analysis vs. Latent Class Analysis.

    PubMed

    Sartipi, Majid; Nedjat, Saharnaz; Mansournia, Mohammad Ali; Baigi, Vali; Fotouhi, Akbar

    2016-11-01

    Some variables like Socioeconomic Status (SES) cannot be directly measured, instead, so-called 'latent variables' are measured indirectly through calculating tangible items. There are different methods for measuring latent variables such as data reduction methods e.g. Principal Components Analysis (PCA) and Latent Class Analysis (LCA). The purpose of our study was to measure assets index- as a representative of SES- through two methods of Non-Linear PCA (NLPCA) and LCA, and to compare them for choosing the most appropriate model. This was a cross sectional study in which 1995 respondents filled the questionnaires about their assets in Tehran. The data were analyzed by SPSS 19 (CATPCA command) and SAS 9.2 (PROC LCA command) to estimate their socioeconomic status. The results were compared based on the Intra-class Correlation Coefficient (ICC). The 6 derived classes from LCA based on BIC, were highly consistent with the 6 classes from CATPCA (Categorical PCA) (ICC = 0.87, 95%CI: 0.86 - 0.88). There is no gold standard to measure SES. Therefore, it is not possible to definitely say that a specific method is better than another one. LCA is a complicated method that presents detailed information about latent variables and required one assumption (local independency), while NLPCA is a simple method, which requires more assumptions. Generally, NLPCA seems to be an acceptable method of analysis because of its simplicity and high agreement with LCA.

  3. Development of an Encompassing Questionnaire for Evaluating the Outcomes Following Total Knee Arthroplasty.

    PubMed

    Chughtai, Morad; Khlopas, Anton; Thomas, Melbin; Gwam, Chukwuweike U; Jauregui, Julio J; Elmallah, Randa K; Roche, Martin; Delanois, Ronald E

    2017-01-10

    There are many standardized scales and questionnaires used to evaluate TKA patients; however, individually they do not always assess patients adequately. Consequently, many are used in combinations to provide a thorough evaluation. However, this leads to redundancy, confusion, and an excessive patient time-burden. Therefore, the purpose of this study was to develop a usable combined knee questionnaire that combines questions in a non-redundant manner. Specifically, we aimed to: 1) create a combined knee questionnaire that encompasses questions from multiple systems, while eliminating redundancy; 2) correlate the new system with the existing validated questionnaires; and 3) determine the length of time it takes to administer this new questionnaire. In a previous study, it was determined that the six most commonly cited validated systems to assess the knee were the: Knee Society Score (KSS), The Western Ontario and McMaster Universities Arthritis Index (WOMAC), Knee injury and Osteoarthritis Outcome Score (KOOS), Lower Extremity Functional Scale (LEFS), Activity Rating Scale (ARS), and Short-Form-36 (SF-36). Therefore, we ensured that the new questionnaire encompassed all elements of these systems. After development of the combined questionnaire, we co-administered it to 20 subjects alongside the above validated questionnaires. We then transposed the corresponding answers from the combined questionnaire to each selected validated system to perform an intra-class correlation analysis. In addition, we recorded the length of time it took to administer the new questionnaire and compared it to the time it took to administer the individual validated questionnaires. Intra-class correlation analysis demonstrated statistically significant positive correlations between the KSS, WOMAC, KOOS, LEFS, ARS, SF-36, and the corresponding questions in the combined questionnaire. The mean length of time it took to administer the combined questionnaire (mean, 10.1 minutes, range, 6.6 to 12.6 minutes) was significantly shorter than the time it took to administer the selected validated questionnaires (mean, 21.3 minutes, range, 17.3 to 24.1 minutes). We have proposed an all-encompassing combined knee questionnaire that eliminates redundancy and inefficiency during the evaluation of TKA patients. It is a reliable, time-efficient system that can be utilized to fill out the most commonly used questionnaires for assessing TKA. Standardization and uniform use of this questionnaire may simplify future patient assessment following TKA.

  4. Psychometric properties of the medical outcomes study: social support survey among methadone maintenance patients in Ho Chi Minh City, Vietnam: a validation study.

    PubMed

    Khuong, Long Quynh; Vu, Tuong-Vi Thi; Huynh, Van-Anh Ngoc; Thai, Truc Thanh

    2018-02-14

    Social support plays a crucial role in the treatment and recovery process of patients engaging in methadone maintenance treatment (MMT). However, there is a paucity of research about social support among MMT patients, possibly due to a lack of appropriate measuring tools. This study aimed to evaluate the psychometric properties of the Vietnamese version of the Medical Outcomes Study: Social Support Survey (MOS-SSS) among MMT patients. A cross-sectional survey of 300 patients was conducted in a methadone clinic in Ho Chi Minh City, Vietnam. MMT patients who agreed to participate in the study completed a face-to-face interview in a private room. The MOS-SSS was translated into Vietnamese using standard forward-backward process. Internal consistency was measured by Cronbach's alpha. The intra-class correlation coefficient was used to determine the test-retest reliability of the MOS-SSS in 75 participants two weeks after the first survey. Concurrent validity of the MOS-SSS was evaluated by correlations with the Multidimensional Scale of Perceived Social Support (MSPSS) and the Perceived Stigma of Addiction Scale (PSAS). Construct validity was investigated by confirmatory factor analysis. The MOS-SSS had good internal consistency with Cronbach's alpha from 0.95 to 0.97 for the four subscales and 0.97 for the overall scale. The two-week test-retest reliability was at moderate level with intra-class correlation coefficients of 0.61-0.73 for the four subscales and 0.76 for the overall scale. Strong significant correlations between the MOS-SSS and the MSPSS (r = 0.77; p < 0.001) and the PSAS (r = - 0.76; p < 0.001) indicated good concurrent validity. Construct validity of the MOS-SSS was established since a final four-factor model fitted the data well with Comparative Fit Index (0.97), Tucker-Lewis Index (0.97), Standardized Root Mean Square Residual (0.03) and Root Mean Square Error of Approximation (0.068; 90% CI = 0.059-0.077). The MOS-SSS is a reliable and valid tool for measuring social support in Vietnamese MMT patients. Further studies among methadone patients at different stages of their treatment and among those from different areas of Vietnam are needed.

  5. Factors influencing agreement between child self-report and parent proxy-reports on the Pediatric Quality of Life Inventory 4.0 (PedsQL) generic core scales.

    PubMed

    Cremeens, Joanne; Eiser, Christine; Blades, Mark

    2006-08-30

    In situations where children are unable or unwilling to respond for themselves, measurement of quality of life (QOL) is often obtained by parent proxy-report. However the relationship between child self and parent proxy-reports has been shown to be poor in some circumstances. Additionally the most appropriate statistical method for comparing ratings between child and parent proxy-reports has not been clearly established. The objectives of this study were to assess the: 1) agreement between child and parent proxy-reports on an established child QOL measure (the PedsQL) using two different statistical methods; 2) effect of chronological age and domain type on agreement between children's and parents' reports on the PedsQL; 3) relationship between parents' own well-being and their ratings of their child's QOL. One hundred and forty-nine healthy children (5.5 - 6.5, 6.5 - 7.5, and 7.5 - 8.5 years) completed the PedsQL. One hundred and three of their parents completed these measures in relation to their child, and a measure of their own QOL (SF-36). Consistency between child and parent proxy-reports on the PedsQL was low, with Intra-Class correlation coefficients ranging from 0.02 to 0.23. Correlations were higher for the oldest age group for Total Score and Psychosocial Health domains, and for the Physical Health domain in the youngest age group. Statistically significant median differences were found between child and parent-reports on all subscales of the PedsQL. The largest median differences were found for the two older age groups. Statistically significant correlations were found between parents' own QOL and their proxy-reports of child QOL across the total sample and within the middle age group. Intra-Class correlation coefficients and median difference testing can provide different information on the relationship between parent proxy-reports and child self-reports. Our findings suggest that differences in the levels of parent-child agreement previously reported may be an artefact of the statistical method used. In addition, levels of agreement can be affected by child age, domains investigated, and parents' own QOL. Further studies are needed to establish the optimal predictors of levels of parent-child agreement.

  6. Intra-abdominal pressure during swimming.

    PubMed

    Moriyama, S; Ogita, F; Huang, Z; Kurobe, K; Nagira, A; Tanaka, T; Takahashi, H; Hirano, Y

    2014-02-01

    The present study aimed to determine the intra-abdominal pressure during front crawl swimming at different velocities in competitive swimmers and to clarify the relationships between stroke indices and changes in intra-abdominal pressure. The subjects were 7 highly trained competitive collegiate male swimmers. Intra-abdominal pressure was measured during front crawl swimming at 1.0, 1.2 and 1.4 m · s(-1) and during the Valsalva maneuver. Intra-abdominal pressure was taken as the difference between minimum and maximum values, and the mean of 6 stable front crawl stroke cycles was used. Stroke rate and stroke length were also measured as stroke indices. There were significant differences in stroke rate among all velocities (P < 0.05). However, there was no significant difference in stroke length by velocity. Significant within-subject correlations between intra-abdominal pressure and stroke rate or stroke length (P < 0.01) were observed, although there were no significant correlations between intra-abdominal pressure and stroke indices when controlling for swimming velocity. These findings do not appear to support the effectiveness of trunk training performed by competitive swimmers aimed at increasing intra-abdominal pressure. © Georg Thieme Verlag KG Stuttgart · New York.

  7. [Intra-anesthetic arterial hypotension in elderly patients during emergency surgery: what are the risk factors?

    PubMed

    Boubacar Ba, El Hadji; Leye, Papa Alassane; Traoré, Mamadou Mour; Ndiaye, Pape Ibrahima; Gaye, Ibrahima; Bah, Mamadou Diawo; Fall, Mamadou Lamine; Diouf, Elisabeth

    2017-01-01

    Emergency anesthesia in elderly patients aged 65 years and older is complex. The occurrence of intraoperative incidents and arterial hypotension is conditioned by patients' initial health status and by the quality of intraoperative management. This study aimed to determine the incidence of intra-anesthetic arterial hypotension in elderly patients during emergency surgery and to assess the involvement of certain factors in its occurrence: age, sex, patient's history, ASA class, anesthetic technique. We conducted a retrospective descriptive and analytical study in the Emergency Surgery Department at the Aristide Le Dantec University Hospital from 1 March 2014 to 28 February 2015. We collected data from 210 patients out of 224 elderly patients aged 65 years and older undergoing emergency anesthesias (10.93%). Data of 101 men and 109 women were included in the analysis, of whom 64.3% had at least one defect. Patients' preoperative status was assessed using American Society of Anesthesiology (ASA) classification: 71% of patients were ASA class 1 and 2 and 29% were ASA class 3 and 4. Locoregional anesthesia was the most practiced anesthetic technique (56.7%). 28 patients (13.33%) had intra-anesthetic arterial hypotension, of whom 16 under general anesthesia and 12 under locoregional anesthesia. It was more frequent in patients with high ASA class and a little less frequent in patients with PAH and underlying heart disease. Arterial hypotension in elderly patients during emergency surgery exposes the subject to the risk of not negligible intraoperative hypotension, especially in patients with high ASA class. Prevention is based on adequate preoperative assessment and anesthetic management.

  8. Correlation of intra-tumor 18F-FDG uptake heterogeneity indices with perfusion CT derived parameters in colorectal cancer.

    PubMed

    Tixier, Florent; Groves, Ashley M; Goh, Vicky; Hatt, Mathieu; Ingrand, Pierre; Le Rest, Catherine Cheze; Visvikis, Dimitris

    2014-01-01

    Thirty patients with proven colorectal cancer prospectively underwent integrated 18F-FDG PET/DCE-CT to assess the metabolic-flow phenotype. Both CT blood flow parametric maps and PET images were analyzed. Correlations between PET heterogeneity and perfusion CT were assessed by Spearman's rank correlation analysis. Blood flow visualization provided by DCE-CT images was significantly correlated with 18F-FDG PET metabolically active tumor volume as well as with uptake heterogeneity for patients with stage III/IV tumors (|ρ|:0.66 to 0.78; p-value<0.02). The positive correlation found with tumor blood flow indicates that intra-tumor heterogeneity of 18F-FDG PET accumulation reflects to some extent tracer distribution and consequently indicates that 18F-FDG PET intra-tumor heterogeneity may be associated with physiological processes such as tumor vascularization.

  9. Cone-Beam Computed Tomography Assessment of Lower Facial Asymmetry in Unilateral Cleft Lip and Palate and Non-Cleft Patients with Class III Skeletal Relationship.

    PubMed

    Lin, Yifan; Chen, Gui; Fu, Zhen; Ma, Lian; Li, Weiran

    2015-01-01

    To evaluate, using cone-beam computed tomography (CBCT), both the condylar-fossa relationships and the mandibular and condylar asymmetries between unilateral cleft lip and palate (UCLP) patients and non-cleft patients with class III skeletal relationship, and to investigate the factors of asymmetry contributing to chin deviation. The UCLP and non-cleft groups consisted of 30 and 40 subjects, respectively, in mixed dentition with class III skeletal relationships. Condylar-fossa relationships and the dimensional and positional asymmetries of the condyles and mandibles were examined using CBCT. Intra-group differences were compared between two sides in both groups using a paired t-test. Furthermore, correlations between each measurement and chin deviation were assessed. It was observed that 90% of UCLP and 67.5% of non-cleft subjects had both condyles centered, and no significant asymmetry was found. The axial angle and the condylar center distances to the midsagittal plane were significantly greater on the cleft side than on the non-cleft side (P=0.001 and P=0.028, respectively) and were positively correlated with chin deviation in the UCLP group. Except for a larger gonial angle on the cleft side, the two groups presented with consistent asymmetries showing shorter mandibular bodies and total mandibular lengths on the cleft (deviated) side. The average chin deviation was 1.63 mm to the cleft side, and the average absolute chin deviation was significantly greater in the UCLP group than in the non-cleft group (P=0.037). Compared with non-cleft subjects with similar class III skeletal relationships, the subjects with UCLP showed more severe lower facial asymmetry. The subjects with UCLP presented with more asymmetrical positions and rotations of the condyles on axial slices, which were positively correlated with chin deviation.

  10. Semiautomatic regional segmentation to measure orbital fat volumes in thyroid-associated ophthalmopathy. A validation study.

    PubMed

    Comerci, M; Elefante, A; Strianese, D; Senese, R; Bonavolontà, P; Alfano, B; Bonavolontà, B; Brunetti, A

    2013-08-01

    This study was designed to validate a novel semi-automated segmentation method to measure regional intra-orbital fat tissue volume in Graves' ophthalmopathy. Twenty-four orbits from 12 patients with Graves' ophthalmopathy, 24 orbits from 12 controls, ten orbits from five MRI study simulations and two orbits from a digital model were used. Following manual region of interest definition of the orbital volumes performed by two operators with different levels of expertise, an automated procedure calculated intra-orbital fat tissue volumes (global and regional, with automated definition of four quadrants). In patients with Graves' disease, clinical activity score and degree of exophthalmos were measured and correlated with intra-orbital fat volumes. Operator performance was evaluated and statistical analysis of the measurements was performed. Accurate intra-orbital fat volume measurements were obtained with coefficients of variation below 5%. The mean operator difference in total fat volume measurements was 0.56%. Patients had significantly higher intra-orbital fat volumes than controls (p<0.001 using Student's t test). Fat volumes and clinical score were significantly correlated (p<0.001). The semi-automated method described here can provide accurate, reproducible intra-orbital fat measurements with low inter-operator variation and good correlation with clinical data.

  11. Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.

    PubMed

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2017-05-22

    Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying kinesthesia after stroke.

  12. Student performance of the general physical examination in internal medicine: an observational study.

    PubMed

    Haring, Catharina M; Cools, Bernadette M; van der Meer, Jos Wm; Postma, Cornelis T

    2014-04-08

    Many practicing physicians lack skills in physical examination. It is not known whether physical examination skills already show deficiencies after an early phase of clinical training. At the end of the internal medicine clerkship students are expected to be able to perform a general physical examination in every new patient encounter. In a previous study, the basic physical examination items that should standardly be performed were set by consensus. The aim of the current observational study was to assess whether medical students were able to correctly perform a general physical examination regarding completeness as well as technique at the end of the clerkship internal medicine. One hundred students who had just finished their clerkship internal medicine were asked to perform a general physical examination on a standardized patient as they had learned during the clerkship. They were recorded on camera. Frequency of performance of each component of the physical examination was counted. Adequacy of performance was determined as either correct or incorrect or not assessable using a checklist of short descriptions of each physical examination component. A reliability analysis was performed by calculation of the intra class correlation coefficient for total scores of five physical examinations rated by three trained physicians and for their agreement on performance of all items. Approximately 40% of the agreed standard physical examination items were not performed by the students. Students put the most emphasis on examination of general parameters, heart, lungs and abdomen. Many components of the physical examination were not performed as was taught during precourses. Intra-class correlation was high for total scores of the physical examinations 0.91 (p <0.001) and for agreement on performance of the five physical examinations (0.79-0.92 p <0.001). In conclusion, performance of the general physical examination was already below expectation at the end of the internal medicine clerkship. Possible causes and suggestions for improvement are discussed.

  13. Student performance of the general physical examination in internal medicine: an observational study

    PubMed Central

    2014-01-01

    Background Many practicing physicians lack skills in physical examination. It is not known whether physical examination skills already show deficiencies after an early phase of clinical training. At the end of the internal medicine clerkship students are expected to be able to perform a general physical examination in every new patient encounter. In a previous study, the basic physical examination items that should standardly be performed were set by consensus. The aim of the current observational study was to assess whether medical students were able to correctly perform a general physical examination regarding completeness as well as technique at the end of the clerkship internal medicine. Methods One hundred students who had just finished their clerkship internal medicine were asked to perform a general physical examination on a standardized patient as they had learned during the clerkship. They were recorded on camera. Frequency of performance of each component of the physical examination was counted. Adequacy of performance was determined as either correct or incorrect or not assessable using a checklist of short descriptions of each physical examination component. A reliability analysis was performed by calculation of the intra class correlation coefficient for total scores of five physical examinations rated by three trained physicians and for their agreement on performance of all items. Results Approximately 40% of the agreed standard physical examination items were not performed by the students. Students put the most emphasis on examination of general parameters, heart, lungs and abdomen. Many components of the physical examination were not performed as was taught during precourses. Intra-class correlation was high for total scores of the physical examinations 0.91 (p <0.001) and for agreement on performance of the five physical examinations (0.79-0.92 p <0.001). Conclusions In conclusion, performance of the general physical examination was already below expectation at the end of the internal medicine clerkship. Possible causes and suggestions for improvement are discussed. PMID:24712683

  14. Isolated glenohumeral range of motion, excluding side-to-side difference in humeral retroversion, in asymptomatic high-school baseball players.

    PubMed

    Mihata, Teruhisa; Takeda, Atsushi; Kawakami, Takeshi; Itami, Yasuo; Watanabe, Chisato; Doi, Munekazu; Neo, Masashi

    2016-06-01

    Glenohumeral range of motion is correlated with shoulder capsular condition and is thus considered to be predictive of shoulder pathology. However, in throwing athletes, a side-to-side difference in humeral retroversion makes it difficult to evaluate capsular condition on the basis of glenohumeral range of motion measured by using the conventional technique. The purpose of this study was to measure isolated glenohumeral rotation, excluding side-to-side differences in humeral retroversion, in asymptomatic high-school baseball players. A total of 195 high-school baseball players (52 pitchers and 143 position players; median age, 16 years) and 20 high-school non-throwing athletes (median age, 16 years) without any shoulder symptoms were enroled in this study. Glenohumeral external and internal rotations were measured by using both a conventional technique and our ultrasound-assisted technique. This technique, neutral rotation, was standardized on the basis of the ultrasonographically visualized location of the bicipital groove to exclude side-to-side differences in humeral retroversion from the calculated rotation angle. Intra- and inter-observer agreements of rotational measurements were evaluated by using intra-class correlation coefficients (ICCs). Isolated glenohumeral rotation measurements, excluding side-to-side differences in humeral retroversion, demonstrated excellent intra-observer (ICC > 0.89) and inter-observer (ICC > 0.78) agreements. Isolated glenohumeral internal rotation was significantly less in the dominant shoulder than in the non-dominant shoulder in asymptomatic baseball players (P < 0.001). Isolated glenohumeral external rotation in baseball players was significantly greater than in non-throwing athletes (P < 0.05). In the baseball players, humeral torsion in the dominant shoulder was significantly greater than that in the non-dominant shoulder (P < 0.001), indicating that the retroversion angle was greater in dominant shoulders than in non-dominant shoulders. Isolated glenohumeral external and internal rotations can be measured with high intra- and inter-observer reliability with the exclusion of side-to-side differences in humeral retroversion. Capsular and muscular changes in the throwing shoulder may be better evaluated by using our ultrasound-assisted technique. Cross-sectional study, Level III.

  15. N-acetyl-aspartate levels correlate with intra-axonal compartment parameters from diffusion MRI.

    PubMed

    Grossman, Elan J; Kirov, Ivan I; Gonen, Oded; Novikov, Dmitry S; Davitz, Matthew S; Lui, Yvonne W; Grossman, Robert I; Inglese, Matilde; Fieremans, Els

    2015-09-01

    Diffusion MRI combined with biophysical modeling allows for the description of a white matter (WM) fiber bundle in terms of compartment specific white matter tract integrity (WMTI) metrics, which include intra-axonal diffusivity (Daxon), extra-axonal axial diffusivity (De||), extra-axonal radial diffusivity (De┴), axonal water fraction (AWF), and tortuosity (α) of extra-axonal space. Here we derive these parameters from diffusion kurtosis imaging to examine their relationship to concentrations of global WM N-acetyl-aspartate (NAA), creatine (Cr), choline (Cho) and myo-Inositol (mI), as measured with proton MR spectroscopy ((1)H-MRS), in a cohort of 25 patients with mild traumatic brain injury (MTBI). We found statistically significant (p<0.05) positive correlations between NAA and Daxon, AWF, α, and fractional anisotropy; negative correlations between NAA and De,┴ and the overall radial diffusivity (D┴). These correlations were supported by similar findings in regional analysis of the genu and splenium of the corpus callosum. Furthermore, a positive correlation in global WM was noted between Daxon and Cr, as well as a positive correlation between De|| and Cho, and a positive trend between De|| and mI. The specific correlations between NAA, an endogenous probe of the neuronal intracellular space, and WMTI metrics related to the intra-axonal space, combined with the specific correlations of De|| with mI and Cho, both predominantly present extra-axonally, corroborate the overarching assumption of many advanced modeling approaches that diffusion imaging can disentangle between the intra- and extra-axonal compartments in WM fiber bundles. Our findings are also generally consistent with what is known about the pathophysiology of MTBI, which appears to involve both intra-axonal injury (as reflected by a positive trend between NAA and Daxon) as well as axonal shrinkage, demyelination, degeneration, and/or loss (as reflected by correlations between NAA and De┴, AWF, and α). Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Wood-inhabiting fungi in southern Italy forest stands: morphogroups, vegetation types and decay classes.

    PubMed

    Granito, Vito Mario; Lunghini, Dario; Maggi, Oriana; Persiani, Anna Maria

    2015-01-01

    The authors conducted an ecological study of forests subjected to varying management. The aim of the study was to extend and integrate, within a multivariate context, knowledge of how saproxylic fungal communities behave along altitudinal/vegetational gradients in response to the varying features and quality of coarse woody debris (CWD). The intra-annual seasonal monitoring of saproxylic fungi, based on sporocarp inventories, was used to investigate saproxylic fungi in relation to vegetation types and management categories. We analyzed fungal species occurrence, recorded according to the presence/absence and frequency of sporocarps, on the basis of the harvest season, of coarse woody debris decay classes as well as other environmental and ecological variables. Two-way cluster analysis, DCA and Spearman's rank correlations, for indirect gradient analysis, were performed to identify any patterns of seasonality and decay. Most of the species were found on CWD in an intermediate decay stage. The first DCA axis revealed the vegetational/microclimate gradient as the main driver of fungal community composition, while the second axis corresponded to a strong gradient of CWD decay classes. © 2015 by The Mycological Society of America.

  17. An improved SRC method based on virtual samples for face recognition

    NASA Astrophysics Data System (ADS)

    Fu, Lijun; Chen, Deyun; Lin, Kezheng; Li, Ao

    2018-07-01

    The sparse representation classifier (SRC) performs classification by evaluating which class leads to the minimum representation error. However, in real world, the number of available training samples is limited due to noise interference, training samples cannot accurately represent the test sample linearly. Therefore, in this paper, we first produce virtual samples by exploiting original training samples at the aim of increasing the number of training samples. Then, we take the intra-class difference as data representation of partial noise, and utilize the intra-class differences and training samples simultaneously to represent the test sample in a linear way according to the theory of SRC algorithm. Using weighted score level fusion, the respective representation scores of the virtual samples and the original training samples are fused together to obtain the final classification results. The experimental results on multiple face databases show that our proposed method has a very satisfactory classification performance.

  18. Reliability of the School Food Checklist for in-school audits and photograph analysis of children's packed lunches.

    PubMed

    Mitchell, S A; Miles, C L; Brennan, L; Matthews, J

    2010-02-01

    Assessment of children's diets is problematic, typically relying on error-prone parent or child recall or reporting, or resource intensive direct observation. The School Food Checklist (SFC) is an objective instrument comprising of 20 food and beverage categories designed to measure the foods contained in children's packed lunches. The present study aimed to assess intra-rater and inter-rater reliability of each of the food and beverage categories of the SFC for both in-school audits and photograph analysis of children's school lunches. Participants comprised 176 children aged 5-8 years from five primary schools in Northern Metropolitan Melbourne. The SFC was used to measure the foods contained in children's packed lunches in the school setting and using photographs. Photograph analysis was conducted by the auditors 2-3 months after completion of in-school audits. Both intra-rater [intra-class correlation coefficient (ICC) = 0.78-1] and inter-rater (ICC = 0.50-0.95) reliability analysis indicated strong agreement for in-school auditing. With the exception of the food category titled 'leftovers', there was strong intra-rater reliability for auditors' live audits and their analysis of photographs [ICC = 0.57-0.98 (Auditor 1); ICC = 0.72-0.90 (Auditor 2)], and strong inter-rater reliability for photograph analysis (ICC = 0.68-0.92). The SFC is a reliable method of measuring the foods and beverages contained in children's packed lunches when used in the school setting or for photograph analysis. This finding has broad implications, particularly for the use of photograph analysis, because this approach offers a convenient and cost effective method of measuring what food and beverages children bring to school in home packed lunches.

  19. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry

    PubMed Central

    Sacco, I.C.N.; Picon, A.P.; Ribeiro, A.P.; Sartor, C.D.; Camargo-Junior, F.; Macedo, D.O.; Mori, E.T.T.; Monte, F.; Yamate, G.Y.; Neves, J.G.; Kondo, V.E.; Aliberti, S.

    2012-01-01

    The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol. PMID:22911379

  20. Relationship between the alpha and beta angles in diagnosing CAM-type femoroacetabular impingement on frog-leg lateral radiographs.

    PubMed

    Khan, Moin; Ranawat, Anil; Williams, Dale; Gandhi, Rajiv; Choudur, Hema; Parasu, Naveen; Simunovic, Nicole; Ayeni, Olufemi R

    2015-09-01

    Alpha and beta angles are commonly used radiographic measures to assess the sphericity of the proximal femur and distance between the pathologic head-neck junction and the acetabular rim, respectively. The aim of this study was to explore the relationship between these two measurements on frog-leg lateral hip radiographs. Fifty frog-leg lateral hip radiographs were evaluated by two orthopaedic surgeons and two radiologists. Each reviewer measured the alpha and beta angles on two separate occasions to determine the relationship between positive alpha and beta angles and the inter- and intra-observer reliability of these measurements. There was no significant association between positive alpha and beta angles, [kappa range -0.043 (95 % CI -0.17 to 0.086) to 0.54 (95 % CI 0.33-0.75)]. Intra-observer reliability was high [alpha angle intra-class correlation coefficient (ICC) range 0.74 (95 % CI 0.58-0.84) to 0.99 (95 % CI 0.98-0.99) and beta angle ICC range 0.86 (95 % CI 0.76-0.92) to 0.97 (95 % CI 0.95-0.98)]. There is no statistical or functional relationship between readings of positive alpha and beta angles. The radiographic measurements resulted in high intra-observer and fair-to-moderate inter-observer reliability. Results of this study suggest that the presence of a CAM lesion on lateral radiographs as suggested by a positive alpha angle does not necessitate a decrease in clearance between the femoral head and acetabular rim as measured by the beta angle and thus may not be the best measure of functional impingement. Understanding the relationship between these two aspects of femoroacetabular impingement improves a surgeon's ability to anticipate potential operative management.

  1. Phases of match-play in professional Australian Football: Descriptive analysis and reliability assessment.

    PubMed

    Rennie, Michael J; Watsford, Mark L; Spurrs, Robert W; Kelly, Stephen J; Pine, Matthew J

    2018-06-01

    To examine the frequency and time spent in the phases of Australian Football (AF) match-play and to assess the intra-assessor reliability of coding these phases of match-play. Observational, intra-reliability assessment. Video footage of 10 random quarters of AF match-play were coded by a single researcher. Phases of offence, defence, contested play, umpire stoppage, set shot and goal reset were coded using a set of operational definitions. Descriptive statistics were provided for all phases of match-play. Following a 6-month washout period, intra-coder reliability was assessed using typical error of measurement (TEM) and intra-class correlation coefficients (ICC). A quarter of AF match-play involved 128±20 different phases of match-play. The highest proportion of match-play involved contested play (25%), followed by offence (18%), defence (18%) and umpire stoppages (18%). The mean duration of offence, defence, contested play, umpire stoppage, set shot and goal reset were 14, 14, 10, 11, 28 and 47s, respectively. No differences were found between the two coding assessments (p>0.05). ICCs for coding the phases of play demonstrated very high reliability (r=0.902-0.992). TEM of the total time spent in each phase of play represented moderate to good reliability (TEM=1.8-9.3%). Coding of offence, defence and contested play tended to display slightly poorer TEMs than umpire stoppages, set shots and goal resets (TEM=8.1 vs 4.5%). Researchers can reliably code the phases of AF match-play which may permit the analysis of specific elements of competition. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry.

    PubMed

    Sacco, I C N; Picon, A P; Ribeiro, A P; Sartor, C D; Camargo-Junior, F; Macedo, D O; Mori, E T T; Monte, F; Yamate, G Y; Neves, J G; Kondo, V E; Aliberti, S

    2012-09-01

    The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.

  3. Diagnostic accuracy of sleep bruxism scoring in absence of audio-video recording: a pilot study.

    PubMed

    Carra, Maria Clotilde; Huynh, Nelly; Lavigne, Gilles J

    2015-03-01

    Based on the most recent polysomnographic (PSG) research diagnostic criteria, sleep bruxism is diagnosed when >2 rhythmic masticatory muscle activity (RMMA)/h of sleep are scored on the masseter and/or temporalis muscles. These criteria have not yet been validated for portable PSG systems. This pilot study aimed to assess the diagnostic accuracy of scoring sleep bruxism in absence of audio-video recordings. Ten subjects (mean age 24.7 ± 2.2) with a clinical diagnosis of sleep bruxism spent one night in the sleep laboratory. PSG were performed with a portable system (type 2) while audio-video was recorded. Sleep studies were scored by the same examiner three times: (1) without, (2) with, and (3) without audio-video in order to test the intra-scoring and intra-examiner reliability for RMMA scoring. The RMMA event-by-event concordance rate between scoring without audio-video and with audio-video was 68.3 %. Overall, the RMMA index was overestimated by 23.8 % without audio-video. However, the intra-class correlation coefficient (ICC) between scorings with and without audio-video was good (ICC = 0.91; p < 0.001); the intra-examiner reliability was high (ICC = 0.97; p < 0.001). The clinical diagnosis of sleep bruxism was confirmed in 8/10 subjects based on scoring without audio-video and in 6/10 subjects with audio-video. Although the absence of audio-video recording, the diagnostic accuracy of assessing RMMA with portable PSG systems appeared to remain good, supporting their use for both research and clinical purposes. However, the risk of moderate overestimation in absence of audio-video must be taken into account.

  4. Intra- Versus Intersex Aggression: Testing Theories of Sex Differences Using Aggression Networks.

    PubMed

    Wölfer, Ralf; Hewstone, Miles

    2015-08-01

    Two theories offer competing explanations of sex differences in aggressive behavior: sexual-selection theory and social-role theory. While each theory has specific strengths and limitations depending on the victim's sex, research hardly differentiates between intrasex and intersex aggression. In the present study, 11,307 students (mean age = 14.96 years; 50% girls, 50% boys) from 597 school classes provided social-network data (aggression and friendship networks) as well as physical (body mass index) and psychosocial (gender and masculinity norms) information. Aggression networks were used to disentangle intra- and intersex aggression, whereas their class-aggregated sex differences were analyzed using contextual predictors derived from sexual-selection and social-role theories. As expected, results revealed that sexual-selection theory predicted male-biased sex differences in intrasex aggression, whereas social-role theory predicted male-biased sex differences in intersex aggression. Findings suggest the value of explaining sex differences separately for intra- and intersex aggression with a dual-theory framework covering both evolutionary and normative components. © The Author(s) 2015.

  5. Reactive Radial Diffusion Model for the Aging/Sequestration Process

    NASA Astrophysics Data System (ADS)

    Ginn, T. R.; Basagaoglu, H.; McCoy, B. J.; Scow, K. M.

    2001-12-01

    A radial diffusion model has been formulated to simulate age-dependent bioavailability of chemical compounds to micro-organisms residing outside (and/or inside) the porous soil particles. Experimental findings in the literature indicate that the sequestration and reduction in bioavailability of contaminants are controlled presumably by the diffusion-limited sorption kinetics and the time-variant desorption process. Here we combine radial-diffusion mass transfer modeling with the exposure-time concept to generate mass-balance equations for the intra- and extra-particle concentrations. The model accomodates reversible sorption kinetics involving sorption time-dependence of the rate coefficients, distinct intra- and extra-particle biodegradation rates; and a dynamic mass interaction between the intra- and extra-particle concentrations arising from the radial diffusion concept. The model explicitly treats multiple particle classes distributed in size and chemical properties in a bulk aquifer or soil volume, which allows the simulation of the sequestration and bioavailability of contaminants in different particle size classes that have distinct diffusion, reaction, and aging properties.

  6. Translation and validation of chronic liver disease questionnaire (CLDQ) in Tamil language.

    PubMed

    Goel, Amit; Arivazhagan, Karunanithi; Sasi, Avani; Shanmugam, Vanathy; Koshi, Seleena; Pottakkat, Biju; Lakshmi, C P; Awasthi, Ashish

    2017-05-01

    Chronic liver disease questionnaire (CLDQ), a self-administered quality-of-life (QOL) instrument for chronic liver disease (CLD) patients, was originally developed in English language. We aimed to translate and validate CLDQ in Tamil language (CLDQ-T). CLDQ-T, prepared by two forward and two backward independent translations by four bilingual (Tamil and English) persons, and repeated iterative modifications, was validated in adult, native-Tamil patients with CLD. CLDQ-T was re-tested in some patients 2 weeks later. Convergent validity was assessed using Spearman's correlation, and discriminant validity by comparison with World Health Organization's brief QOL tool (WHOQOL-BREF). Reliability was assessed through internal consistency (Cronbach's alpha) and test-retest reliability (intra-class correlation). Cutoff used for statistical significance was p<0.05. The study included 126 patients (age: mean [SD] 46 years [12.5]; male 104; cause: alcohol 42%, HBV 25%, HCV 4%, cryptogenic 29%; CTP class A 47%, B 37%, and C 16%). In convergent validity, all domains except the "abdominal domain" showed significant correlation between CLDQ-T and WHOQOL-BREF. Patients with severe disease had lower scores for all domains of CLDQ-T except the "abdominal" domain, but not for any of the domains for WHOQOL-BREF. Overall Cronbach's alpha was 0.942, and more than 0.7 for all the individual domains except the "activity" domain. On retesting in 44 (35%) patients, intraclass correlation coefficient was 0.879 for the overall CLDQ-T score and >0.700 for individual domains. CLDQ-T was easily understood and showed good performance characteristics in assessing QOL in Tamil-speaking patients with CLD.

  7. Evaluation of adrenocortical function in Florida manatees (Trichechus manatus latirostris)

    USGS Publications Warehouse

    Tripp, K.M.; Verstegen, J.P.; Deutsch, C.; Bonde, Robert K.; de Wit, M.; Manire, Charles A.; Gaspard, J.; Harr, K.E.

    2011-01-01

    The study objectives were to determine the predominant manatee glucocorticoid; validate assays to measure this glucocorticoid and adrenocorticotropic hormone (ACTH); determine diagnostic thresholds to distinguish physiological vs. pathological concentrations; identify differences associated with sex, age class, female reproductive status, capture time, and lactate; and determine the best methods for manatee biologists and clinicians to diagnose stress. Cortisol is the predominant manatee glucocorticoid. IMMULITE 1000 assays for cortisol and ACTH were validated. Precision yielded intra- and inter-assay coefficients of variation for serum cortisol: ≤23.5 and ≤16.7%; and ACTH: ≤6.9 and ≤8.5%. Accuracy resulted in a mean adjusted R(2)≥0.87 for serum cortisol and ≥0.96 for ACTH. Assay analytical sensitivities for cortisol (0.1 µg/dl) and ACTH (10.0 pg/ml) were verified. Methods were highly correlated with another IMMULITE 1000 for serum cortisol (r=0.97) and ACTH (r=0.98). There was no significant variation in cortisol or ACTH with sex or age class and no correlation with female progesterone concentrations. Cortisol concentrations were highest in unhealthy manatees, chronically stressed by disease or injury. ACTH was greatest in healthy free-ranging or short-term rehabilitating individuals, peracutely stressed by capture and handling. Cortisol concentrations ≥1.0 µg/dl were diagnostic of chronic stress; ACTH concentrations ≥87.5 pg/ml were diagnostic of peracute stress. In healthy long-term captive manatees, cortisol (0.4±0.2 µg/dl) and ACTH (47.7±15.9 pg/ml) concentrations were lower than healthy free-ranging, short-term rehabilitated or unhealthy manatees. Capture time was not significantly correlated with cortisol; ACTH correlation was borderline significant. Cortisol and ACTH were positively correlated with lactate.

  8. Evaluation of adrenocortical function in Florida manatees (Trichechus manatus latirostris).

    PubMed

    Tripp, Kathleen M; Verstegen, John P; Deutsch, Charles J; Bonde, Robert K; de Wit, Martine; Manire, Charles A; Gaspard, Joseph; Harr, Kendal E

    2011-01-01

    The study objectives were to determine the predominant manatee glucocorticoid; validate assays to measure this glucocorticoid and adrenocorticotropic hormone (ACTH); determine diagnostic thresholds to distinguish physiological vs. pathological concentrations; identify differences associated with sex, age class, female reproductive status, capture time, and lactate; and determine the best methods for manatee biologists and clinicians to diagnose stress. Cortisol is the predominant manatee glucocorticoid. IMMULITE 1000 assays for cortisol and ACTH were validated. Precision yielded intra- and inter-assay coefficients of variation for serum cortisol: ≤23.5 and ≤16.7%; and ACTH: ≤6.9 and ≤8.5%. Accuracy resulted in a mean adjusted R(2)≥0.87 for serum cortisol and ≥0.96 for ACTH. Assay analytical sensitivities for cortisol (0.1 µg/dl) and ACTH (10.0 pg/ml) were verified. Methods were highly correlated with another IMMULITE 1000 for serum cortisol (r=0.97) and ACTH (r=0.98). There was no significant variation in cortisol or ACTH with sex or age class and no correlation with female progesterone concentrations. Cortisol concentrations were highest in unhealthy manatees, chronically stressed by disease or injury. ACTH was greatest in healthy free-ranging or short-term rehabilitating individuals, peracutely stressed by capture and handling. Cortisol concentrations ≥1.0 µg/dl were diagnostic of chronic stress; ACTH concentrations ≥87.5 pg/ml were diagnostic of peracute stress. In healthy long-term captive manatees, cortisol (0.4±0.2 µg/dl) and ACTH (47.7±15.9 pg/ml) concentrations were lower than healthy free-ranging, short-term rehabilitated or unhealthy manatees. Capture time was not significantly correlated with cortisol; ACTH correlation was borderline significant. Cortisol and ACTH were positively correlated with lactate. © 2010 Wiley-Liss, Inc.

  9. Measurement error of mean sac diameter and crown-rump length among pregnant women at Mulago hospital, Uganda.

    PubMed

    Ali, Sam; Byanyima, Rosemary Kusaba; Ononge, Sam; Ictho, Jerry; Nyamwiza, Jean; Loro, Emmanuel Lako Ernesto; Mukisa, John; Musewa, Angella; Nalutaaya, Annet; Ssenyonga, Ronald; Kawooya, Ismael; Temper, Benjamin; Katamba, Achilles; Kalyango, Joan; Karamagi, Charles

    2018-05-04

    Ultrasonography is essential in the prenatal diagnosis and care for the pregnant mothers. However, the measurements obtained often contain a small percentage of unavoidable error that may have serious clinical implications if substantial. We therefore evaluated the level of intra and inter-observer error in measuring mean sac diameter (MSD) and crown-rump length (CRL) in women between 6 and 10 weeks' gestation at Mulago hospital. This was a cross-sectional study conducted from January to March 2016. We enrolled 56 women with an intrauterine single viable embryo. The women were scanned using a transvaginal (TVS) technique by two observers who were blinded of each other's measurements. Each observer measured the CRL twice and the MSD once for each woman. Intra-class correlation coefficients (ICCs), 95% limits of agreement (LOA) and technical error of measurement (TEM) were used for analysis. Intra-observer ICCs for CRL measurements were 0.995 and 0.993 while inter-observer ICCs were 0.988 for CRL and 0.955 for MSD measurements. Intra-observer 95% LOA for CRL were ± 2.04 mm and ± 1.66 mm. Inter-observer LOA were ± 2.35 mm for CRL and ± 4.87 mm for MSD. The intra-observer relative TEM for CRL were 4.62% and 3.70% whereas inter-observer relative TEM were 5.88% and 5.93% for CRL and MSD respectively. Intra- and inter-observer error of CRL and MSD measurements among pregnant women at Mulago hospital were acceptable. This implies that at Mulago hospital, the error in pregnancy dating is within acceptable margins of ±3 days in first trimester, and the CRL and MSD cut offs of ≥7 mm and ≥ 25 mm respectively are fit for diagnosis of miscarriage on TVS. These findings should be extrapolated to the whole country with caution. Sonographers can achieve acceptable and comparable diagnostic accuracy levels of MSD and CLR measurements with proper training and adherence to practice guidelines.

  10. Inter-Observer and Intra-Observer Reliability of Clinical Assessments in Knee Osteoarthritis

    PubMed Central

    Maricar, Nasimah; Callaghan, Michael J; Parkes, Matthew J; Felson, David T; O’Neill, Terence W

    2016-01-01

    Background Clinical examination of the knee is subject to measurement error. The aim of this analysis was to determine inter- and intra-observer reliability of commonly used clinical tests in patients with knee osteoarthritis(OA). Methods We studied subjects with symptomatic knee OA who were participants in an open-label clinical trial of intra-articular steroid therapy. Following standardisation of the clinical test procedures, two clinicians assessed 25 subjects independently at the same visit, and the same clinician assessed 88 subjects over an interval period of 2–10 weeks; in both cases prior to the steroid intervention. Clinical examination included assessment of bony enlargement, crepitus, quadriceps wasting, knee effusion, joint-line and anserine tenderness and knee range of movement(ROM). Intra-class correlation coefficients(ICC), estimated kappa(κ), weighted kappa(κω) and Bland and Altman plots were used to determine inter- and intra-observer levels of agreement. Results Using Landis and Koch criteria, inter-observer kappa scores were moderate for patellofemoral joint(κ=0.53) and anserine tenderness(κ=0.48); good for bony enlargement(κ=0.66), quadriceps wasting(κ=0.78), crepitus(κ=0.78), medial tibiofemoral joint tenderness(κ=0.76), and effusion assessed by ballottement(κ=0.73) and bulge sign(κω =0.78); and excellent for lateral tibiofemoral joint tenderness(κ=1.00), flexion(ICC=0.97) and extension(ICC=0.87) ROM. Intra-observer kappa scores were moderate for lateral tibiofemoral joint tenderness(κ=0.60), good for crepitus(κ=0.78), effusion assessed by ballottement test(κ=0.77), patellofemoral joint(κ=0.66), medial tibiofemoral joint(κ=0.64) and anserine(κ=0.73) tenderness and excellent for effusion assessed by bulge sign(κω =0.83), bony enlargement(κ=0.98), quadriceps wasting(κ=0.83), flexion(ICC=0.99) and extension(ICC=0.96) ROM. Conclusion Among individuals with symptomatic knee OA, the reliability of clinical examination of the knee was at least good for the majority of clinical signs of knee OA. PMID:27909143

  11. Inter- and intra-individual variation in urinary biomarker concentrations over a 6-day sampling period. Part 1: metals.

    PubMed

    Smolders, Roel; Koch, Holger M; Moos, Rebecca K; Cocker, John; Jones, Kate; Warren, Nick; Levy, Len; Bevan, Ruth; Hays, Sean M; Aylward, Lesa L

    2014-12-01

    The aim of the current HBM-study is to further the understanding of the impact of inter- and intra-individual variability in HBM surveys as it may have implications for the design and interpretation of the study outcomes. As spot samples only provide a snapshot in time of the concentrations of chemicals in an individual, it remains unclear to what extent intra-individual variability plays a role in the overall variability of population-wide HBM surveys. The current paper describes the results of an intensive biomonitoring study, in which all individual urine samples of 8 individuals were collected over a 6-day sampling period (a total of 352 unique samples). By analyzing different metals (As, Cd, Mn, Ni) in each individual sample, inter- and intra-individual variability for these four metals could be determined, and the relationships between exposure, internal dose, and sampling protocol assessed. Although the range of biomarker values for different metals was well within the normal range reported in large-scale population surveys, large intra-individual differences over a 6-day period could also be observed. Typically, measured biomarker values span at least an order of magnitude within an individual, and more if specific exposure episodes could be identified. Fish consumption for example caused a twenty- to thirty-fold increase in urinary As-levels over a period of 2-6h. Intra-class correlation coefficients (ICC) were typically low for uncorrected biomarker values (between 0.104 and 0.460 for the 4 metals), but improved when corrected for creatinine or specific gravity (SG). The results show that even though urine is a preferred matrix for HBM studies, there are certain methodological issues that need to be taken into account in the interpretation of urinary biomarker data, related to the intrinsic variability of the urination process itself, the relationship between exposure events and biomarker quantification, and the timing of sampling. When setting up HBM-projects, this expected relationship between individual exposure episode and urinary biomarker concentration needs to be taken into account. Copyright © 2014. Published by Elsevier Ireland Ltd.

  12. Reproducibility of thoracic kyphosis measurements in patients with adolescent idiopathic scoliosis.

    PubMed

    Ohrt-Nissen, Søren; Cheung, Jason Pui Yin; Hallager, Dennis Winge; Gehrchen, Martin; Kwan, Kenny; Dahl, Benny; Cheung, Kenneth M C; Samartzis, Dino

    2017-01-01

    Current surgical treatment for adolescent idiopathic scoliosis (AIS) involves correction in both the coronal and sagittal plane, and thorough assessment of these parameters is essential for evaluation of surgical results. However, various definitions of thoracic kyphosis (TK) have been proposed, and the intra- and inter-rater reproducibility of these measures has not been determined. As such, the purpose of the current study was to determine the intra- and inter-rater reproducibility of several TK measurements used in the assessment of AIS. Twenty patients (90% females) surgically treated for AIS with alternate-level pedicle screw fixation were included in the study. Three raters independently evaluated pre- and postoperative standing lateral plain radiographs. For each radiograph, several definitions of TK were measured as well as L1-S1 and nonfixed lumbar lordosis. All variables were measured twice 14 days apart, and a mixed effects model was used to determine the repeatability coefficient (RC), which is a measure of the agreement between repeated measurements. Also, the intra- and inter-rater intra-class correlation coefficient (ICC) was determined as a measure of reliability. Preoperative median Cobb angle was 58° (range 41°-86°), and median surgical curve correction was 68% (range 49-87%). Overall intra-rater RC was highest for T2-T12 and nonfixed TK (11°) and lowest for T4-T12 and T5-T12 (8°). Inter-rater RC was highest for T1-T12, T1-nonfixed, and nonfixed TK (13°) and lowest for T5-T12 (9°). Agreement varied substantially between pre- and postoperative radiographs. Inter-rater ICC was highest for T4-T12 (0.92; 95% CI 0.88-0.95) and T5-T12 (0.92; 95% CI 0.88-0.95) and lowest for T1-nonfixed (0.80; 95% CI 0.72-0.88). Considerable variation for all TK measurements was noted. Intra- and inter-rater reproducibility was best for T4-T12 and T5-T12. Future studies should consider adopting a relevant minimum difference as a limit for true change in TK.

  13. Dual mobility hip arthroplasty wear measurement: Experimental accuracy assessment using radiostereometric analysis (RSA).

    PubMed

    Pineau, V; Lebel, B; Gouzy, S; Dutheil, J-J; Vielpeau, C

    2010-10-01

    The use of dual mobility cups is an effective method to prevent dislocations. However, the specific design of these implants can raise the suspicion of increased wear and subsequent periprosthetic osteolysis. Using radiostereometric analysis (RSA), migration of the femoral head inside the cup of a dual mobility implant can be defined to apprehend polyethylene wear rate. The study aimed to establish the precision of RSA measurement of femoral head migration in the cup of a dual mobility implant, and its intra- and interobserver variability. A total hip prosthesis phantom was implanted and placed under weight loading conditions in a simulator. Model-based RSA measurement of implant penetration involved specially machined polyethylene liners with increasing concentric wear (no wear, then 0.25, 0.5 and 0.75mm). Three examiners, blinded to the level of wear, analyzed (10 times) the radiostereometric films of the four liners. There was one experienced, one trained, and one inexperienced examiner. Statistical analysis measured the accuracy, precision, and intra- and interobserver variability by calculating Root Mean Square Error (RMSE), Concordance Correlation Coefficient (CCC), Intra Class correlation Coefficient (ICC), and Bland-Altman plots. Our protocol, that used a simple geometric model rather than the manufacturer's CAD files, showed precision of 0.072mm and accuracy of 0.034mm, comparable with machining tolerances with low variability. Correlation between wear measurement and true value was excellent with a CCC of 0.9772. Intraobserver reproducibility was very good with an ICC of 0.9856, 0.9883 and 0.9842, respectively for examiners 1, 2 and 3. Interobserver reproducibility was excellent with a CCC of 0.9818 between examiners 2 and 1, and 0.9713 between examiners 3 and 1. Quantification of wear is indispensable for the surveillance of dual mobility implants. This in vitro study validates our measurement method. Our results, and comparison with other studies using different measurement technologies (RSA, standard radiographs, Martell method) make model-based RSA the reference method for measuring the wear of total hip prostheses in vivo. Level 3. Prospective diagnostic study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  14. iHADAMAC: A complementary tool for sequential resonance assignment of globular and highly disordered proteins

    NASA Astrophysics Data System (ADS)

    Feuerstein, Sophie; Plevin, Michael J.; Willbold, Dieter; Brutscher, Bernhard

    2012-01-01

    An experiment, iHADAMAC, is presented that yields information on the amino-acid type of individual residues in a protein by editing the 1H- 15N correlations into seven different 2D spectra, each corresponding to a different class of amino-acid types. Amino-acid type discrimination is realized via a Hadamard encoding scheme based on four different spin manipulations as recently introduced in the context of the sequential HADAMAC experiment. Both sequential and intra-residue HADAMAC experiments yield highly complementary information that greatly facilitate resonance assignment of proteins with high frequency degeneracy, as demonstrated here for a 188-residue intrinsically disordered protein fragment of the hepatitis C virus protein NS5A.

  15. The French press: a repeatable and high-throughput approach to exercising zebrafish (Danio rerio).

    PubMed

    Usui, Takuji; Noble, Daniel W A; O'Dea, Rose E; Fangmeier, Melissa L; Lagisz, Malgorzata; Hesselson, Daniel; Nakagawa, Shinichi

    2018-01-01

    Zebrafish are increasingly used as a vertebrate model organism for various traits including swimming performance, obesity and metabolism, necessitating high-throughput protocols to generate standardized phenotypic information. Here, we propose a novel and cost-effective method for exercising zebrafish, using a coffee plunger and magnetic stirrer. To demonstrate the use of this method, we conducted a pilot experiment to show that this simple system provides repeatable estimates of maximal swim performance (intra-class correlation [ICC] = 0.34-0.41) and observe that exercise training of zebrafish on this system significantly increases their maximum swimming speed. We propose this high-throughput and reproducible system as an alternative to traditional linear chamber systems for exercising zebrafish and similarly sized fishes.

  16. The French press: a repeatable and high-throughput approach to exercising zebrafish (Danio rerio)

    PubMed Central

    Usui, Takuji; Noble, Daniel W.A.; O’Dea, Rose E.; Fangmeier, Melissa L.; Lagisz, Malgorzata; Hesselson, Daniel

    2018-01-01

    Zebrafish are increasingly used as a vertebrate model organism for various traits including swimming performance, obesity and metabolism, necessitating high-throughput protocols to generate standardized phenotypic information. Here, we propose a novel and cost-effective method for exercising zebrafish, using a coffee plunger and magnetic stirrer. To demonstrate the use of this method, we conducted a pilot experiment to show that this simple system provides repeatable estimates of maximal swim performance (intra-class correlation [ICC] = 0.34–0.41) and observe that exercise training of zebrafish on this system significantly increases their maximum swimming speed. We propose this high-throughput and reproducible system as an alternative to traditional linear chamber systems for exercising zebrafish and similarly sized fishes. PMID:29372124

  17. Image quality guided approach for adaptive modelling of biometric intra-class variations

    NASA Astrophysics Data System (ADS)

    Abboud, Ali J.; Jassim, Sabah A.

    2010-04-01

    The high intra-class variability of acquired biometric data can be attributed to several factors such as quality of acquisition sensor (e.g. thermal), environmental (e.g. lighting), behavioural (e.g. change face pose). Such large fuzziness of biometric data can cause a big difference between an acquired and stored biometric data that will eventually lead to reduced performance. Many systems store multiple templates in order to account for such variations in the biometric data during enrolment stage. The number and typicality of these templates are the most important factors that affect system performance than other factors. In this paper, a novel offline approach is proposed for systematic modelling of intra-class variability and typicality in biometric data by regularly selecting new templates from a set of available biometric images. Our proposed technique is a two stage algorithm whereby in the first stage image samples are clustered in terms of their image quality profile vectors, rather than their biometric feature vectors, and in the second stage a per cluster template is selected from a small number of samples in each clusters to create an ultimate template sets. These experiments have been conducted on five face image databases and their results will demonstrate the effectiveness of proposed quality guided approach.

  18. Effect of biotin supplementation on meat quality of F1 Wagyu/Black Angus feedlot steers of known genotype.

    PubMed

    Lawrence, R J; Doyle, J C; Elliott, R; Norton, B W; Loxton, I

    2007-10-01

    Biotin (D-biotin) was supplemented to F1 Wagyu/Black Angus steers fed a wheat-based ration to evaluate the effect on meat quality. One hundred and eight steers of known Wagyu sire lines were assigned to three biotin treatments (0, 10 and 20mg/head/day) with each treatment replicated four times using an unfasted liveweight of 410.5kg (±24.42 SD). Biotin supplementation had no effect (P>0.05) on beef marbling standard at either the 5/6th or 10/11th rib quartering site, 10/11th rib intra-muscular fat percentage, intra-muscular fat fatty acid composition or adipose melting points. Wagyu genotype had an effect (P<0.05) on beef marbling standard and intra-muscular fat percentage at the 10/11th rib, inter-muscular and intra-muscular melting point and fatty acid composition of intra-muscular fat. A significant (P<0.001) but poor correlation existed between beef marbling standard and intra-muscular fat percentage (R(2)=0.198). Total conjugated linoleic acid had a highly significantly (P<0.0001) positive correlation to intra-muscular fat percentage (R(2)=0.446).

  19. Validation of the Walking Impairment Questionnaire for Spanish patients.

    PubMed

    Lozano, Francisco S; March, José R; González-Porras, José R; Carrasco, Eduardo; Lobos, José M; Areitio-Aurtena, Alix

    2013-09-01

    The Walking Impairment Questionnaire (WIQ) is a short, easy to complete, disease-specific questionnaire to assess intermittent claudication. A Spanish version of the WIQ for Hispanic Americans has recently been validated in Texas, but it needs to be validated for European Spanish people. After translation and cultural adaptation of the WIQ, 920 patients with intermittent claudication (ankle brachial index < 0.9) completed two questionnaires (Spanish version of the WIQ and European Quality of Life 5 Dimension [EQ-5D]). The validity of the WIQ was determined by correlating WIQ and EQ-5D. Test-retest reliability and internal consistency were determined using the intra-class correlation coefficient (ICC) and Cronbach's alpha, respectively. The three domains of the WIQ were moderately correlated with the EQ-5D health outcome (r = 0.54 to 0.60; p < 0.001). Test-retest reliabilities ranged from ICC = 0.89 to 0.91 and internal consistency (Cronbach's alpha = 0.92) was high. The Spanish version of the WIQ for European Spanish patients was valid and reproducible, suggesting that it could be used in Spanish patients with intermittent claudication.

  20. The Reliability and Validity of the Perceived Dietary Adherence Questionnaire for People with Type 2 Diabetes

    PubMed Central

    Asaad, Ghada; Sadegian, Maryam; Lau, Rita; Xu, Yunke; Soria-Contreras, Diana C.; Bell, Rhonda C.; Chan, Catherine B.

    2015-01-01

    Nutrition therapy is essential for diabetes treatment, and assessment of dietary intake can be time consuming. The purpose of this study was to develop a reliable and valid instrument to measure diabetic patients’ adherence to Canadian diabetes nutrition recommendations. Specific information derived from three, repeated 24-h dietary recalls of 64 type 2 diabetic patients, aged 59.2 ± 9.7 years, was correlated with a total score and individual items of the Perceived Dietary Adherence Questionnaire (PDAQ). Test-retest reliability was completed by 27 type 2 diabetic patients, aged 62.8 ± 8.4 years. The correlation coefficients for PDAQ items versus 24-h recalls ranged from 0.46 to 0.11. The intra-class correlation (0.78) was acceptable, indicating good reliability. The results suggest that PDAQ is a valid and reliable measure of diabetes nutrition recommendations. Because it is quick to administer and score, it may be useful as a screening tool in research and as a clinical tool to monitor dietary adherence. PMID:26198247

  1. Research of Face Recognition with Fisher Linear Discriminant

    NASA Astrophysics Data System (ADS)

    Rahim, R.; Afriliansyah, T.; Winata, H.; Nofriansyah, D.; Ratnadewi; Aryza, S.

    2018-01-01

    Face identification systems are developing rapidly, and these developments drive the advancement of biometric-based identification systems that have high accuracy. However, to develop a good face recognition system and to have high accuracy is something that’s hard to find. Human faces have diverse expressions and attribute changes such as eyeglasses, mustache, beard and others. Fisher Linear Discriminant (FLD) is a class-specific method that distinguishes facial image images into classes and also creates distance between classes and intra classes so as to produce better classification.

  2. Validation of the FASH (Functional Assessment Scale for Acute Hamstring Injuries) questionnaire for German-speaking football players.

    PubMed

    Lohrer, Heinz; Nauck, Tanja; Korakakis, Vasileios; Malliaropoulos, Nikos

    2016-10-24

    The FASH (Functional Assessment Scale for Acute Hamstring Injuries) questionnaire has been recently developed as a disease-specific self-administered questionnaire for use in Greek, English, and German languages. Its psychometric qualities (validity and reliability) were tested only in Greek-speaking patients mainly representing track and field athletes. As hamstring injuries represent the most common football injury, we tested the validity and reliability of the FASH-G (G = German version) questionnaire in German-speaking footballers suffering from acute hamstring injuries. The FASH-G questionnaire was tested for reliability and validity, in 16 footballers with hamstring injuries (patients' group), 77 asymptomatic footballers (healthy group), and 19 field hockey players (at-risk group). Known-group validity was tested by comparing the total FASH-G scores of the injured and non-injured groups. Reliability of the FASH-G questionnaire was analysed in 18 asymptomatic footballers using the intra-class coefficient. Known-group validity was demonstrated by significant differences between injured and non-injured participants (p < 0.001). The FASH-G exhibited very good test-retest reliability (intra-class correlation coefficient = 0.982, p < 0.001). Internal consistency was excellent (α = 0.938). Compared with the results presented in the original publication, no statistical differences were found between healthy athletes (p = 0.257), but patients' groups and at-risk groups presented scoring differences (p = 0.040 and <0.001, respectively). The FASH-G is a valid and reliable instrument to assess and determine the severity of hamstring injuries in German footballers.

  3. Measurement of open apices in tooth roots in Colombian children as a tool for human identification in asylum and criminal proceedings.

    PubMed

    Rivera, Marcela; De Luca, Stefano; Aguilar, Lina; Velandia Palacio, Luz Andrea; Galić, Ivan; Cameriere, Roberto

    2017-05-01

    Dental age estimation was recognized as an imperative issue in clinical and medico-legal practice. However, very few studies on dental age estimation in children have been published in Colombia. This study evaluated the accuracy of Cameriere's method of measurement of open apices on tooth roots in a sample of 526 digital panoramic radiographs (OPTs) of children (274 boys and 252 girls), aged between 6 and 14 years, from Bogotá, Valle del Cauca, Buga and Villavicencio, in Southwest Colombia. Only first seven permanent lower teeth, except third molar, from the left side of mandible were studied. Difference between dental age and chronological age was evaluated for boys and girls across nine age classes. Intra-class correlation coefficient and Kappa score was used to test intra- and inter-observer agreement error rate. Dental age was overestimated by 0.08 years and standard deviation (±SD) of 0.68 years in boys which was not statistically significant (p = 0.06), while in girls dental age underestimated by -0.25 ± 0.65 years which was statistically significant difference (p < 0.001). The absolute difference between DA and CA or mean prediction error (ME) was 0.57 ± 0.38 years in boys and 0.57 ± 0.41 in girls (p = 0.966) which implies that Cameriere's European formula is similarly accurate in both sexes in this sample of Colombian children. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    PubMed

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  5. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    PubMed Central

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-01-01

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. PMID:27089369

  6. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    PubMed

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. The Arthroscopic Surgical Skill Evaluation Tool (ASSET)

    PubMed Central

    Koehler, Ryan J.; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J.; Nicandri, Gregg T.

    2014-01-01

    Background Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. Hypothesis The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability, when used to assess the technical ability of surgeons performing diagnostic knee arthroscopy on cadaveric specimens. Study Design Cross-sectional study; Level of evidence, 3 Methods Content validity was determined by a group of seven experts using a Delphi process. Intra-articular performance of a right and left diagnostic knee arthroscopy was recorded for twenty-eight residents and two sports medicine fellowship trained attending surgeons. Subject performance was assessed by two blinded raters using the ASSET. Concurrent criterion-oriented validity, inter-rater reliability, and test-retest reliability were evaluated. Results Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in total ASSET score (p<0.05) between novice, intermediate, and advanced experience groups were identified. Inter-rater reliability: The ASSET scores assigned by each rater were strongly correlated (r=0.91, p <0.01) and the intra-class correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: there was a significant correlation between ASSET scores for both procedures attempted by each individual (r = 0.79, p<0.01). Conclusion The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopy in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live OR and other simulated environments. PMID:23548808

  8. 78 FR 13389 - Self-Regulatory Organizations; C2 Options Exchange, Incorporated; Notice of Filing of a Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-27

    ...-adjusted option series of the Market-Maker's appointed class that have a time to expiration of less than... liquidity in these few series, it would only last for a short period of time (until the following trading... language to Exchange Rules 8.5 and 8.17 to exclude intra-day add-on series (``Intra-day Adds'') on the day...

  9. Twin Brothers with Autism and Their Intra-Pair Interactions in a Pre-School Special Education Class

    ERIC Educational Resources Information Center

    Markodimitraki, Maria; Ampartzaki, Maria; Kypriotaki, Maria; Linardakis, Michalis

    2017-01-01

    The present study focused on the intra-pair interaction of a pair of dizygotic twins with autism in pre-school age and explored: (a) the type of play and the level of symbolic play the twins prefer and are most frequently engaged with; (b) the attitudes the twins usually display; (c) the most frequent initiator of interactions; and (d) the way the…

  10. Malocclusion Class II division 1 skeletal and dental relationships measured by cone-beam computed tomography.

    PubMed

    Xu, Yiling; Oh, Heesoo; Lagravère, Manuel O

    2017-09-01

    The purpose of this study was to locate traditionally-used landmarks in two-dimensional (2D) images and newly-suggested ones in three-dimensional (3D) images (cone-beam computer tomographies [CBCTs]) and determine possible relationships between them to categorize patients with Class II-1 malocclusion. CBCTs from 30 patients diagnosed with Class II-1 malocclusion were obtained from the University of Alberta Graduate Orthodontic Program database. The reconstructed images were downloaded and visualized using the software platform AVIZO ® . Forty-two landmarks were chosen and the coordinates were then obtained and analyzed using linear and angular measurements. Ten images were analyzed three times to determine the reliability and measurement error of each landmark using Intra-Class Correlation coefficient (ICC). Descriptive statistics were done using the SPSS statistical package to determine any relationships. ICC values were excellent for all landmarks in all axes, with the highest measurement error of 2mm in the y-axis for the Gonion Left landmark. Linear and angular measurements were calculated using the coordinates of each landmark. Descriptive statistics showed that the linear and angular measurements used in the 2D images did not correlate well with the 3D images. The lowest standard deviation obtained was 0.6709 for S-GoR/N-Me, with a mean of 0.8016. The highest standard deviation was 20.20704 for ANS-InfraL, with a mean of 41.006. The traditional landmarks used for 2D malocclusion analysis show good reliability when transferred to 3D images. However, they did not reveal specific skeletal or dental patterns when trying to analyze 3D images for malocclusion. Thus, another technique should be considered when classifying 3D CBCT images for Class II-1malocclusion. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  11. Intra-lesional spatial correlation of static and dynamic FET-PET parameters with MRI-based cerebral blood volume in patients with untreated glioma.

    PubMed

    Göttler, Jens; Lukas, Mathias; Kluge, Anne; Kaczmarz, Stephan; Gempt, Jens; Ringel, Florian; Mustafa, Mona; Meyer, Bernhard; Zimmer, Claus; Schwaiger, Markus; Förster, Stefan; Preibisch, Christine; Pyka, Thomas

    2017-03-01

    18 F-fluorethyltyrosine-(FET)-PET and MRI-based relative cerebral blood volume (rCBV) have both been used to characterize gliomas. Recently, inter-individual correlations between peak static FET-uptake and rCBV have been reported. Herein, we assess the local intra-lesional relation between FET-PET parameters and rCBV. Thirty untreated glioma patients (27 high-grade) underwent simultaneous PET/MRI on a 3 T hybrid scanner obtaining structural and dynamic susceptibility contrast sequences. Static FET-uptake and dynamic FET-slope were correlated with rCBV within tumour hotspots across patients and intra-lesionally using a mixed-effects model to account for inter-individual variation. Furthermore, maximal congruency of tumour volumes defined by FET-uptake and rCBV was determined. While the inter-individual relationship between peak static FET-uptake and rCBV could be confirmed, our intra-lesional, voxel-wise analysis revealed significant positive correlations (median r = 0.374, p < 0.0001). Similarly, significant inter- and intra-individual correlations were observed between FET-slope and rCBV. However, rCBV explained only 12% of the static and 5% of the dynamic FET-PET variance and maximal overlap of respective tumour volumes was 37% on average. Our results show that the relation between peak values of MR-based rCBV and static FET-uptake can also be observed intra-individually on a voxel basis and also applies to a dynamic FET parameter, possibly determining hotspots of higher biological malignancy. However, just a small part of the FET-PET signal variance is explained by rCBV and tumour volumes determined by the two modalities showed only moderate overlap. These findings indicate that FET-PET and MR-based rCBV provide both congruent and complimentary information on glioma biology.

  12. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    PubMed Central

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  13. Cross-cultural adaptation and validation to Brazil of the Obesity-related Problems Scale.

    PubMed

    Brasil, Andreia Mara Brolezzi; Brasil, Fábio; Maurício, Angélica Aparecida; Vilela, Regina Maria

    2017-01-01

    To validate a reliable version of the Obesity-related Problems Scale in Portuguese to use it in Brazil. The Obesity-related Problems Scale was translated and transculturally adapted. Later it was simultaneously self-applied with a 12-item version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0), to 50 obese patients and 50 non-obese individuals, and applied again to half of them after 14 days. The Obesity-related Problems scale was able to differentiate obese from non-obese individuals with higher accuracy than WHODAS 2.0, correlating with this scale and with body mass index. The factor analysis determined a two-dimensional structure, which was confirmed with χ2/df=1.81, SRMR=0.05, and CFI=0.97. The general a coefficient was 0.90 and the inter-item intra-class correlation, in the reapplication, ranged from 0.75 to 0.87. The scale proved to be valid and reliable for use in the Brazilian population, without the need to exclude items.

  14. In vitro performance of near infrared light transillumination at 780-nm and digital radiography for detection of non-cavitated approximal caries.

    PubMed

    Abogazalah, N; Eckert, G J; Ando, M

    2017-08-01

    To evaluate the ability of a Near Infrared Light Transillumination (NILT) device to detect non-cavitated approximal caries lesions; and to compare its performance to Digital Radiography (DR). Thirty human extracted premolars (sound to lesions into the outer one-third of dentin) were selected. Lesion depth was confirmed by micro-computed tomography (μ-CT). Teeth were mounted in a custom-made device to simulate approximal contact. DR and NILT (CariVu™, DEXIS, LLC, Hatfield, PA, USA) examinations were performed and repeated by three trained and calibrated examiners. Sensitivity, specificity, area under ROC curve (A z ), inter- and intra-class correlation coefficients (ICCs) for each method, and correlation among the methods were determined. ICCs for intra-/inter-examiner agreement were substantial for NILT (0.69/0.64), and moderate for DR (0.52/0.48). Sensitivity/specificity for NILT and DR were 0.68/0.93 and 0.50/0.64, respectively. A z for NILT was 0.81, while for DR it was 0.61. Spearman correlation coefficient with μ-CT for NILT (0.65, p<0.001) demonstrated moderate association, while that of DR suggested no association (0.19, p=0.289). Within the limitations of this in vitro study, NILT demonstrated a potential for early approximal caries detection. NILT and DR performed the same regarding the accuracy for non-cavitated approximal caries detection; however, NILT was superior to DR in terms of repeatability, agreement and correlation with μ-CT. A commercial version of NILT was recently introduced as a non-irradiative adjunctive caries detection method. It uses near infrared (NIR) light at 780-nm to transilluminate teeth and captures live images from the occlusal surface. This study demonstrates that NILT can be used as an alternative to radiography for non-cavitated approximal caries detection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Long-term stability of intra-oral maxillary distraction in unilateral cleft lip and palate: a case report.

    PubMed

    Nevzatoğlu, Sirin; Küçükkeleş, Nazan; Güzel, Zeki

    2013-11-01

    This case report presents short and long-term treatment results of a unilateral cleft lip and palate patient treated with a modified intra-oral tooth-bone borne distraction appliance. The chief complaints of a 16 year-old, unilateral cleft lip and palate patient were poor facial aesthetics, crowding and a fistula. Severe maxillary retrognathism was treated via distraction osteogenesis of the maxilla and performed using an intra-oral tooth-bone borne appliance. Treatment continued to completion with a multibracket system. At an eight-year review following the distraction procedure, the short and long-term results were determined cephalometrically. Following the distraction, A-point advanced 7 mm, 2 mm of which relapsed during fixed appliance treatment. At the end of the active treatment, the patient's skeletal and dental Class III relationship improved to Class I, which was preserved at the long-term review. The profile was markedly improved by the distraction osteogenesis. In cases of severe maxillary retrognathism as a result of a cleft lip and palate, maxillary distraction osteogenesis provides a viable alternative to orthognathic surgery.

  16. A Multi-modal, Discriminative and Spatially Invariant CNN for RGB-D Object Labeling.

    PubMed

    Asif, Umar; Bennamoun, Mohammed; Sohel, Ferdous

    2017-08-30

    While deep convolutional neural networks have shown a remarkable success in image classification, the problems of inter-class similarities, intra-class variances, the effective combination of multimodal data, and the spatial variability in images of objects remain to be major challenges. To address these problems, this paper proposes a novel framework to learn a discriminative and spatially invariant classification model for object and indoor scene recognition using multimodal RGB-D imagery. This is achieved through three postulates: 1) spatial invariance - this is achieved by combining a spatial transformer network with a deep convolutional neural network to learn features which are invariant to spatial translations, rotations, and scale changes, 2) high discriminative capability - this is achieved by introducing Fisher encoding within the CNN architecture to learn features which have small inter-class similarities and large intra-class compactness, and 3) multimodal hierarchical fusion - this is achieved through the regularization of semantic segmentation to a multi-modal CNN architecture, where class probabilities are estimated at different hierarchical levels (i.e., imageand pixel-levels), and fused into a Conditional Random Field (CRF)- based inference hypothesis, the optimization of which produces consistent class labels in RGB-D images. Extensive experimental evaluations on RGB-D object and scene datasets, and live video streams (acquired from Kinect) show that our framework produces superior object and scene classification results compared to the state-of-the-art methods.

  17. Development of a Peer Teaching-Assessment Program and a Peer Observation and Evaluation Tool

    PubMed Central

    Trujillo, Jennifer M.; Barr, Judith; Gonyeau, Michael; Van Amburgh, Jenny A.; Matthews, S. James; Qualters, Donna

    2008-01-01

    Objectives To develop a formalized, comprehensive, peer-driven teaching assessment program and a valid and reliable assessment tool. Methods A volunteer taskforce was formed and a peer-assessment program was developed using a multistep, sequential approach and the Peer Observation and Evaluation Tool (POET). A pilot study was conducted to evaluate the efficiency and practicality of the process and to establish interrater reliability of the tool. Intra-class correlation coefficients (ICC) were calculated. Results ICCs for 8 separate lectures evaluated by 2-3 observers ranged from 0.66 to 0.97, indicating good interrater reliability of the tool. Conclusion Our peer assessment program for large classroom teaching, which includes a valid and reliable evaluation tool, is comprehensive, feasible, and can be adopted by other schools of pharmacy. PMID:19325963

  18. Investigating the influence of achievement on self-concept using an intra-class design and a comparison of the PASS and SDQ-1 self-concept tests.

    PubMed

    Hay, I; Ashman, A; van Kraayenoord, C E

    1997-09-01

    The formation and measurement of self-concept were the foci of this research. The study aimed to investigate the influence of achievement on academic self-concept and to compare the Perception of Ability Scale for Students (PASS, Boersma & Chapman, 1992) with the Self-Description Questionnaire-1 (SDQ-1, Marsh, 1988). The participants were 479 grade 5 (mean age 126.6 months) coeducational Australian students, located in 18 schools. An intra-class research design was used to investigate the influence of frame-of-reference on self-concept development. As students' academic scores rose above their class mean their self-concepts increased and as students' academic scores fell below their class mean their self-concepts decreased. Students' difference from class mean predicted their self-concept scores. This finding was consistently shown across the reading, spelling, and mathematics domains using test and teaching rating data. A comparison between the PASS and the SDQ-1 demonstrated concurrent validity across self-concept domains. The findings support the notions that the social environment is a significant agent that influences self-concept, and that teacher ratings and standardised tests of achievement and the PASS and the SDQ-1 are valid measures for self-concept research.

  19. The Pooling-score (P-score): inter- and intra-rater reliability in endoscopic assessment of the severity of dysphagia.

    PubMed

    Farneti, D; Fattori, B; Nacci, A; Mancini, V; Simonelli, M; Ruoppolo, G; Genovese, E

    2014-04-01

    This study evaluated the intra- and inter-rater reliability of the Pooling score (P-score) in clinical endoscopic evaluation of severity of swallowing disorder, considering excess residue in the pharynx and larynx. The score (minimum 4 - maximum 11) is obtained by the sum of the scores given to the site of the bolus, the amount and ability to control residue/bolus pooling, the latter assessed on the basis of cough, raclage, number of dry voluntary or reflex swallowing acts (< 2, 2-5, > 5). Four judges evaluated 30 short films of pharyngeal transit of 10 solid (1/4 of a cracker), 11 creamy (1 tablespoon of jam) and 9 liquid (1 tablespoon of 5 cc of water coloured with methlyene blue, 1 ml in 100 ml) boluses in 23 subjects (10 M/13 F, age from 31 to 76 yrs, mean age 58.56±11.76 years) with different pathologies. The films were randomly distributed on two CDs, which differed in terms of the sequence of the films, and were given to judges (after an explanatory session) at time 0, 24 hours later (time 1) and after 7 days (time 2). The inter- and intra-rater reliability of the P-score was calculated using the intra-class correlation coefficient (ICC; 3,k). The possibility that consistency of boluses could affect the scoring of the films was considered. The ICC for site, amount, management and the P-score total was found to be, respectively, 0.999, 0.997, 1.00 and 0.999. Clinical evaluation of a criterion of severity of a swallowing disorder remains a crucial point in the management of patients with pathologies that predispose to complications. The P-score, derived from static and dynamic parameters, yielded a very high correlation among the scores attributed by the four judges during observations carried out at different times. Bolus consistencies did not affect the outcome of the test: the analysis of variance, performed to verify if the scores attributed by the four judges to the parameters selected, might be influenced by the different consistencies of the boluses, was not significant. These initial data validate the clinical use of the P-score in the management of patients with deglutition disorders by a multidisciplinary team.

  20. Is anatomic acetabular orientation related to pelvic morphology? CT analysis of 150 healthy pelvises.

    PubMed

    Sautet, P; Giorgi, H; Chabrand, P; Tropiano, P; Argenson, J-N; Parratte, S; Blondel, B

    2018-05-01

    Links between sagittal spinal alignment and acetabular orientation attract considerable research attention with the goal of optimising prosthetic cup position. However, whether pelvic incidence (PI) is related to anatomic acetabular orientation remains unknown. We therefore conducted a radiological study with the following objectives: to look for correlations between PI and anatomic acetabular parameters; to describe the sacro-pubic angle (SPA), defined by fixed bony pelvic landmarks, and its relations with acetabular anteversion; and to determine whether anatomical parameters (PI and SPA) correlate with demographic characteristics. PI correlates with anatomical acetabular parameters. We conducted a computed tomography (CT) study of the pelvises of 150 patients free of degenerative disease. Three parameters were measured: anatomic acetabular orientation in the Lewinnek reference plane, PI, and the SPA subtended by the line connecting the midpoint of the sacral endplate to the pubic symphysis and the anterior pelvic plane. Statistical tests were performed to look for correlations among these parameters. Intra-observer and inter-observer reproducibility was considered highly satisfactory (inter-class correlation coefficient, >86% and >82%, respectively). Mean PI was 58.6°±10.2° (range, 32.8°-97.6°), with no significant differences between genders or across age groups. Mean SPA was 34.7°±5.5° (range, 18.3°-49.8°). Mean anatomic acetabular anteversion (AAA) was greater in females (23.4°; range, 11.5°-34.5°) than in males (20°; range, 7.5°-34.5°) (P<0.001). PI did not correlate with any of the acetabular parameters (PI/AAA, r=0.8 and P=0.33; PI/acetabular inclination on the horizontal, r=-0.96 and P=0.24). SPA correlated significantly with both PI (r=0.33 and P<0.001) and AAA (r=0.33 and P<0.001). This CT study of normal pelvises showed that AAA was significantly greater in females and that SPA correlated significantly with both PI and acetabular anteversion. SPA could serve to define the "theoretical" AAA of each individual patient and could thus be incorporated into surgical planning protocols or intra-operative guidance methods for hip replacement surgery. IV, retrospective study with no control group. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Empirical solvent-mediated potentials hold for both intra-molecular and inter-molecular inter-residue interactions.

    PubMed Central

    Keskin, O.; Bahar, I.; Badretdinov, A. Y.; Ptitsyn, O. B.; Jernigan, R. L.

    1998-01-01

    Whether knowledge-based intra-molecular inter-residue potentials are valid to represent inter-molecular interactions taking place at protein-protein interfaces has been questioned in several studies. Differences in the chain connectivity effect and in residue packing geometry between interfaces and single chain monomers have been pointed out as possible sources of distinct energetics for the two cases. In the present study, the interfacial regions of protein-protein complexes are examined to extract inter-molecular inter-residue potentials, using the same statistical methods as those previously adopted for intra-molecular residue pairs. Two sets of energy parameters are derived, corresponding to solvent-mediation and "average residue" mediation. The former set is shown to be highly correlated (correlation coefficient 0.89) with that previously obtained for inter-residue interactions within single chain monomers, while the latter exhibits a weaker correlation (0.69) with its intra-molecular counterpart. In addition to the close similarity of intra- and inter-molecular solvent-mediated potentials, they are shown to be significantly more residue-specific and thereby discriminative compared to the residue-mediated ones, indicating that solvent-mediation plays a major role in controlling the effective inter-residue interactions, either at interfaces, or within single monomers. Based on this observation, a reduced set of energy parameters comprising 20 one-body and 3 two-body terms is proposed (as opposed to the 20 x 20 tables of inter-residue potentials), which reproduces the conventional 20 x 20 tables with a correlation coefficient of 0.99. PMID:9865952

  2. Intra-Class Differences in the Post-16 Educational Trajectories of Young People from Lower Socioeconomic Groups

    ERIC Educational Resources Information Center

    Slack, Kim

    2014-01-01

    This paper draws on research with young people from similar working-class backgrounds in a deprived urban area in England. Although all the participants achieved a high enough attainment level to remain in full-time education beyond compulsory schooling, they each elected to follow different post-16 pathways. Drawing on in-depth interviews with…

  3. Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

    PubMed

    Al-Amiry, Bariq; Mahmood, Sarwar; Krupic, Ferid; Sayed-Noor, Arkan

    2017-09-01

    Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

  4. Reliability and validity of tongue color analysis in the prediction of symptom patterns in terms of East Asian Medicine.

    PubMed

    Park, Young-Jae; Lee, Jin-Moo; Yoo, Seung-Yeon; Park, Young-Bae

    2016-04-01

    To examine whether color parameters of tongue inspection (TI) using a digital camera was reliable and valid, and to examine which color parameters serve as predictors of symptom patterns in terms of East Asian medicine (EAM). Two hundred female subjects' tongue substances were photographed by a mega-pixel digital camera. Together with the photographs, the subjects were asked to complete Yin deficiency, Phlegm pattern, and Cold-Heat pattern questionnaires. Using three sets of digital imaging software, each digital image was exposure- and white balance-corrected, and finally L* (luminance), a* (red-green balance), and b* (yellow-blue balance) values of the tongues were calculated. To examine intra- and inter-rater reliabilities and criterion validity of the color analysis method, three raters were asked to calculate color parameters for 20 digital image samples. Finally, four hierarchical regression models were formed. Color parameters showed good or excellent reliability (0.627-0.887 for intra-class correlation coefficients) and significant criterion validity (0.523-0.718 for Spearman's correlation). In the hierarchical regression models, age was a significant predictor of Yin deficiency (β = 0.192), and b* value of the tip of the tongue was a determinant predictor of Yin deficiency, Phlegm, and Heat patterns (β = - 0.212, - 0.172, and - 0.163). Luminance (L*) was predictive of Yin deficiency (β = -0.172) and Cold (β = 0.173) pattern. Our results suggest that color analysis of the tongue using the L*a*b* system is reliable and valid, and that color parameters partially serve as symptom pattern predictors in EAM practice.

  5. Psychometric properties of sleep and coping numeric rating scales in rheumatoid arthritis: a subanalysis of an etanercept trial.

    PubMed

    Avila-Ribeiro, Pedro; Brault, Yves; Dougados, Maxime; Gossec, Laure

    2017-01-01

    In rheumatoid arthritis, quality of sleep and ability to cope are important for patients; however their usefulness as outcome measures is not well established. Post-hoc analysis of an open-label 12-week trial of etanercept in biologic-naïve rheumatoid arthritis patients with visits at screening, baseline and over 12 weeks. Outcomes measured included Disease Activity Score 28 erythrocyte sedimentation rate (DAS28), numeric rating scales for sleep, coping, patient and physician-global assessment, pain and fatigue, and modified-HAQ. Reliability between screening and baseline visits by intra-class correlation, and responsiveness between baseline and 12 weeks by standardised response means were assessed for each outcome. In 108 patients, mean age 54 (standard deviation (SD) 13) years, mean disease duration 8 (SD 7) years, 75% women; disease activity was high at baseline: mean DAS28 5.5 (SD 0.8). Reliability intra-class correlation was 0.83[95% confidence interval: 0.77;0.88] for sleep, 0.81[0.74;0.87] for modified-HAQ, 0.80[0.71;0.86] for fatigue, 0.72[0.62;0.80] for physician-global assessment, 0.66[0.54;076] for coping, 0.65[0.53;0.75] for pain and 0.63[0.50;0.73] for patient-global assessment. Responsiveness standardised response means was 1.65[1.32;2.10] for physician-global assessment, 1.37[1.09;1.73] for pain, 1.36[1.08;1.73] for patient-global assessment, 1.15[0.95;1.41] for fatigue, 0.96[0.70;1.28] for coping, 0.92[0.73;1.15] for sleep and 0.86[0.69;1.07] for modified-HAQ. Numeric rating scales assessing sleep and coping were found to be generally as reliable as 'usual' outcomes in rheumatoid arthritis. Responsiveness was less high, indicating these domains of health may be less accessible to biologic treatment. When assessing the patient's perspective on treatment, it is feasible and valid to measure sleep and coping by numeric rating scales.

  6. Computer-Generated, Three-Dimensional Spine Model From Biplanar Radiographs: A Validity Study in Idiopathic Scoliosis Curves Greater Than 50 Degrees.

    PubMed

    Carreau, Joseph H; Bastrom, Tracey; Petcharaporn, Maty; Schulte, Caitlin; Marks, Michelle; Illés, Tamás; Somoskeöy, Szabolcs; Newton, Peter O

    2014-03-01

    Reproducibility study of SterEOS 3-dimensional (3D) software in large, idiopathic scoliosis (IS) spinal curves. To determine the accuracy and reproducibility of various 3D, software-generated radiographic measurements acquired from a 2-dimensional (2D) imaging system. SterEOS software allows a user to reconstruct a 3D spinal model from an upright, biplanar, low-dose, X-ray system. The validity and internal consistency of this system have not been tested in large IS curves. EOS images from 30 IS patients with curves greater than 50° were collected for analysis. Three observers blinded to the study protocol conducted repeated, randomized, manual 2D measurements, and 3D software generated measurements from biplanar images acquired from an EOS Imaging system. Three-dimensional measurements were repeated using both the Full 3D and Fast 3D guided processes. A total of 180 (120 3D and 60 2D) sets of measurements were obtained of coronal (Cobb angle) and sagittal (T1-T12 and T4-T12 kyphosis; L1-S1 and L1-L5; and pelvic tilt, pelvic incidence, and sacral slope) parameters. Intra-class correlation coefficients were compared, as were the calculated differences in values generated by SterEOS 3D software and manual 2D measurements. The 95% confidence intervals of the mean differences in measures were calculated as an estimate of reproducibility. Average intra-class correlation coefficients were excellent: 0.97, 0.97, and 0.93 for Full 3D, Fast 3D, and 2D measures, respectively (p = .11). Measurement errors for some sagittal measures were significantly lower with the 3D techniques. Both the Full 3D and Fast 3D techniques provided consistent measurements of axial plane vertebral rotation. SterEOS 3D reconstruction spine software creates reproducible measurements in all 3 planes of deformity in curves greater than 50°. Advancements in 3D scoliosis imaging are expected to improve our understanding and treatment of idiopathic scoliosis. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  7. Hand assessment in older adults with musculoskeletal hand problems: a reliability study.

    PubMed

    Myers, Helen L; Thomas, Elaine; Hay, Elaine M; Dziedzic, Krysia S

    2011-01-07

    Musculoskeletal hand pain is common in the general population. This study aims to investigate the inter- and intra-observer reliability of two trained observers conducting a simple clinical interview and physical examination for hand problems in older adults. The reliability of applying the American College of Rheumatology (ACR) criteria for hand osteoarthritis to community-dwelling older adults will also be investigated. Fifty-five participants aged 50 years and over with a current self-reported hand problem and registered with one general practice were recruited from a previous health questionnaire study. Participants underwent a standardised, structured clinical interview and physical examination by two independent trained observers and again by one of these observers a month later. Agreement beyond chance was summarised using Kappa statistics and intra-class correlation coefficients. Median values for inter- and intra-observer reliability for clinical interview questions were found to be "substantial" and "moderate" respectively [median agreement beyond chance (Kappa) was 0.75 (range: -0.03, 0.93) for inter-observer ratings and 0.57 (range: -0.02, 1.00) for intra-observer ratings]. Inter- and intra-observer reliability for physical examination items was variable, with good reliability observed for some items, such as grip and pinch strength, and poor reliability observed for others, notably assessment of altered sensation, pain on resisted movement and judgements based on observation and palpation of individual features at single joints, such as bony enlargement, nodes and swelling. Moderate agreement was observed both between and within observers when applying the ACR criteria for hand osteoarthritis. Standardised, structured clinical interview is reliable for taking a history in community-dwelling older adults with self reported hand problems. Agreement between and within observers for physical examination items is variable. Low Kappa values may have resulted, in part, from a low prevalence of clinical signs and symptoms in the study participants. The decision to use clinical interview and hand assessment variables in clinical practice or further research in primary care should include consideration of clinical applicability and training alongside reliability. Further investigation is required to determine the relationship between these clinical questions and assessments and the clinical course of hand pain and hand problems in community-dwelling older adults.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monney, Claude; Bisogni, Valentina; Zhou, Ke-Jin

    Cuprate materials, such as those hosting high-temperature superconductivity, represent a famous class of materials where the correlations between the strongly entangled charges and spins produce complex phase diagrams. Several years ago, the Zhang-Rice singlet was proposed as a natural quasiparticle in hole-doped cuprates. The occurrence and binding energy of this quasiparticle, consisting of a pair of bound holes with antiparallel spins on the same CuO 4 plaquette, depends on the local electronic interactions, which are fundamental quantities for understanding the physics of the cuprates. Here, we employ state-of-the-art resonant inelastic x-ray scattering (RIXS) to probe the correlated physics of themore » CuO 4 plaquettes in the quasi-one-dimensional chain cuprate Li 2CuO 2. By tuning the incoming photon energy to the O K edge, we populate bound states related to the Zhang-Rice quasiparticles in the RIXS process. Both intra- and interchain Zhang-Rice singlets are observed and their occurrence is shown to depend on the nearest-neighbor spin-spin correlations, which are readily probed in this experiment. Finally, we also extract the binding energy of the Zhang-Rice singlet and identify the Zhang-Rice triplet excitation in the RIXS spectra.« less

  9. Reliability and Validity of the Multidimensional Scale of Perceived Social Support (MSPSS): Thai Version.

    PubMed

    Wongpakaran, Tinakon; Wongpakaran, Nahathai; Ruktrakul, Ruk

    2011-01-01

    This study examines the Thai version of the Multidimensional Scale of Perceived Social Support (MSPSS) for its psychometric properties. In total 462 participants were recruited - 310 medical students from Chiang Mai University and 152 psychiatric patients, and they completed the Thai version of the MSPSS, the State Trait Anxiety Inventory (STAI), the Rosenberg Self-Esteem Scale (RSES) and the Thai Depression Inventory (TDI). Test-retest reliability was conducted over a four week period. Factor analysis produced three-factor solutions for both patient (PG) and student groups (SG), and overall the model demonstrated adequate fit indices. The mean total score and the sub-scale score for the SG were statistically higher than those in the PG, except for 'Significant Others'. The internal consistency of the scale was good, with a Cronbach's alpha of 0.91 for the SG and 0.87 for the PG. After a four week retest for reliability exercise, the intra-class correlation coefficient (ICC) was found to be 0.84. The Thai-MSPSS was found to have a negative correlation with the STAI and the TDI, but was positively correlated with the RSES. The Thai MSPSS is a reliable and valid instrument to use.

  10. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    PubMed

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  11. Translation, cultural adaptation and validation of the Diabetes Attitudes Scale - third version into Brazilian Portuguese 1

    PubMed Central

    Vieira, Gisele de Lacerda Chaves; Pagano, Adriana Silvino; Reis, Ilka Afonso; Rodrigues, Júlia Santos Nunes; Torres, Heloísa de Carvalho

    2018-01-01

    ABSTRACT Objective: to perform the translation, adaptation and validation of the Diabetes Attitudes Scale - third version instrument into Brazilian Portuguese. Methods: methodological study carried out in six stages: initial translation, synthesis of the initial translation, back-translation, evaluation of the translated version by the Committee of Judges (27 Linguists and 29 health professionals), pre-test and validation. The pre-test and validation (test-retest) steps included 22 and 120 health professionals, respectively. The Content Validity Index, the analyses of internal consistency and reproducibility were performed using the R statistical program. Results: in the content validation, the instrument presented good acceptance among the Judges with a mean Content Validity Index of 0.94. The scale presented acceptable internal consistency (Cronbach’s alpha = 0.60), while the correlation of the total score at the test and retest moments was considered high (Polychoric Correlation Coefficient = 0.86). The Intra-class Correlation Coefficient, for the total score, presented a value of 0.65. Conclusion: the Brazilian version of the instrument (Escala de Atitudes dos Profissionais em relação ao Diabetes Mellitus) was considered valid and reliable for application by health professionals in Brazil. PMID:29319739

  12. The city of hope-quality of life-ostomy questionnaire: persian translation and validation.

    PubMed

    Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M

    2014-07-01

    Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future.

  13. Validity and reliability of a new ankle dorsiflexion measurement device.

    PubMed

    Gatt, Alfred; Chockalingam, Nachiappan

    2013-08-01

    The assessment of the maximum ankle dorsiflexion angle is an important clinical examination procedure. Evidence shows that the traditional goniometer is highly unreliable, and various designs of goniometers to measure the maximum ankle dorsiflexion angle rely on the application of a known force to obtain reliable results. Hence, an innovative ankle dorsiflexion measurement device was designed to make this measurement more reliable by holding the foot in a selected posture without the application of a known moment. To report on the comprehensive validity and reliability testing carried out on the new device. Following validity testing, four different trials to test reliability of the ankle dorsiflexion measurement device were performed. These trials included inter-rater and intra-rater testings with a controlled moment, intra-rater reliability testing with knees flexed and extended without a controlled moment, intra-rater testing with a patient population, and inter-rater reliability testing between four raters of varying experience without controlling moment. All raters were blinded. A series of trials to test intra-rater and inter-rater reliabilities. Intra-rater reliability intraclass correlation coefficient was 0.98 and inter-rater reliability intraclass correlation coefficient (2,1) was 0.953 with a controlled moment. With uncontrolled moment, very high reliability for intra-tester was also achieved (intraclass correlation coefficient = 0.94 with knees extended and intraclass correlation coefficient = 0.95 with knees flexed). For the trial investigating test-retest reliability with actual patients, intraclass correlation coefficient of 0.99 was obtained. In the trial investigating four different raters with uncontrolled moment, intraclass correlation coefficient of 0.91 was achieved. The new ankle dorsiflexion measurement device is a valid and reliable device for measuring ankle dorsiflexion in both healthy subjects and patients, with both controlled and uncontrolled moments, even by multiple raters of varying experience when the foot is dorsiflexed to its end of range of motion. An ankle dorsiflexion measuring device has been designed to increase the reliability of ankle dorsiflexion measurement and replace the traditional goniometer. While the majority of similar devices rely on application of a known moment to perform this measurement, it has been shown that this is not required with the new ankle dorsiflexion measurement device and, rather, foot posture should be taken into consideration as this affects the maximum ankle dorsiflexion angle.

  14. Intra- and Inter-rater Agreement of Superior Vena Cava Flow and Right Ventricular Outflow Measurements in Late Preterm and Term Neonates.

    PubMed

    Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike

    2018-02-24

    To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.

  15. Is articular pain in rheumatoid arthritis correlated with ultrasound power Doppler findings?

    PubMed

    Pereira, Daniele Freitas; Gutierrez, Marwin; de Buosi, Ana Leticia Pirozzi; Ferreira, Fernando Bernardes Maia Diniz; Draghessi, Antonella; Grassi, Walter; Natour, Jamil; Furtado, Rita Nely Vilar

    2015-11-01

    The study is addressed to determine if there is a correlation between intra-articular power Doppler (PD) and pain symptoms in patients with rheumatoid arthritis (RA). A cross-sectional study of patients with established RA was rolled out. Seventy-two patients with chronic swelling at metacarpophalangeal (MCP) joints were consecutively enrolled in the study and divided into two groups (painful and painless). In the painful group, the inclusion criteria were pain in the visual analog scale (VAS), from 0 to 10 cm, of at least 4 cm and 0 in the painless group. All two to five MCP joints, bilaterally, were scanned by ultrasound (US) searching for intra-articular PD presence. Any value of p < 0.05 was considered significant. Patients in the painful group had longer morning stiffness, worse 28-joint disease activity score (DAS 28), and health assessment questionnaire (HAQ) indexes. There were no association between pain and gray scale (GS) synovitis, odds ratio (OR) = 0.9 (0.6-1.2), p = 0.485; and pain and intra-articular PD, OR = 0.8 (0.6-1.2), p = 0.244. Intra-articular PD was not correlated with pain symptom in this study.

  16. Decomposition of Ag-based soldering alloys used in space maintainers after intra-oral exposure. A retrieval analysis study.

    PubMed

    Soteriou, Despo; Ntasi, Argyro; Papagiannoulis, Lisa; Eliades, Theodore; Zinelis, Spiros

    2014-02-01

    The aim of this study was to evaluate the elemental alterations of Ag soldering alloys used in space maintainers after intra-oral exposure. Twenty devices were fabricated by using two different soldering alloys; US (Dentaurum Universal Silver Solder, n = 10) and OS (Leone Orthodontic Solder, n = 10). All devices were manufactured by the same technician. Surface morphology and elemental quantitative analysis of the soldering alloys before and after intra-oral placement in patients was determined by scanning electron microscopy and energy-dispersive X-ray microanalysis (SEM/EDX). Statistical analysis was performed by t-test, Mann Whitney tests and Pearson's correlation. For all tests a 95% confidence level was used (α = 0.05). Both soldering alloys demonstrated substantially increase in surface roughness after intra-oral aging. Statistical analysis illustrated a significant decrease in the Cu and Zn content after treatment. OS demonstrated higher Cu release than US (p < 0.05). The remaining relative concentrations of Cu and Zn after the treatment did not show any correlation (p > 0.05) with intra-oral exposure time, apart from Zn in OS (r = 0.840, p = 0.04). Both soldering alloys demonstrated a significant Cu and Zn reduction after intra-oral exposure that may raise biocompatibility concerns.

  17. Responsiveness to change and reliability of measurement of radiographic joint space width in osteoarthritis of the knee: a systematic review.

    PubMed

    Reichmann, W M; Maillefert, J F; Hunter, D J; Katz, J N; Conaghan, P G; Losina, E

    2011-05-01

    The goal of this systematic review was to report the responsiveness to change and reliability of conventional radiographic joint space width (JSW) measurement. We searched the PubMed and Embase databases using the following search criteria: [osteoarthritis (OA) (MeSH)] AND (knee) AND (X-ray OR radiography OR diagnostic imaging OR radiology OR disease progression) AND (joint space OR JSW or disease progression). We assessed responsiveness by calculating the standardized response mean (SRM). We assessed reliability using intra- and inter-reader intra-class correlation (ICC) and coefficient of variation (CV). Random-effects models were used to pool results from multiple studies. Results were stratified by study duration, design, techniques of obtaining radiographs, and measurement method. We identified 998 articles using the search terms. Of these, 32 articles (43 estimates) reported data on responsiveness of JSW measurement and 24 (50 estimates) articles reported data on measures of reliability. The overall pooled SRM was 0.33 [95% confidence interval (CI): 0.26, 0.41]. Responsiveness of change in JSW measurement was improved substantially in studies of greater than 2 years duration (0.57). Further stratifying this result in studies of greater than 2 years duration, radiographs obtained with the knee in a flexed position yielded an SRM of 0.71. Pooled intra-reader ICC was estimated at 0.97 (95% CI: 0.92, 1.00) and the intra-reader CV estimated at 3.0 (95% CI: 2.0, 4.0). Pooled inter-reader ICC was estimated at 0.93 (95% CI: 0.86, 0.99) and the inter-reader CV estimated at 3.4% (95% CI: 1.3%, 5.5%). Measurement of JSW obtained from radiographs in persons with knee is reliable. These data will be useful to clinicians who are planning RCTs where the change in minimum JSW is the outcome of interest. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. A semi-automated algorithm for hypothalamus volumetry in 3 Tesla magnetic resonance images.

    PubMed

    Wolff, Julia; Schindler, Stephanie; Lucas, Christian; Binninger, Anne-Sophie; Weinrich, Luise; Schreiber, Jan; Hegerl, Ulrich; Möller, Harald E; Leitzke, Marco; Geyer, Stefan; Schönknecht, Peter

    2018-07-30

    The hypothalamus, a small diencephalic gray matter structure, is part of the limbic system. Volumetric changes of this structure occur in psychiatric diseases, therefore there is increasing interest in precise volumetry. Based on our detailed volumetry algorithm for 7 Tesla magnetic resonance imaging (MRI), we developed a method for 3 Tesla MRI, adopting anatomical landmarks and work in triplanar view. We overlaid T1-weighted MR images with gray matter-tissue probability maps to combine anatomical information with tissue class segmentation. Then, we outlined regions of interest (ROIs) that covered potential hypothalamus voxels. Within these ROIs, seed growing technique helped define the hypothalamic volume using gray matter probabilities from the tissue probability maps. This yielded a semi-automated method with short processing times of 20-40 min per hypothalamus. In the MRIs of ten subjects, reliabilities were determined as intraclass correlations (ICC) and volume overlaps in percent. Three raters achieved very good intra-rater reliabilities (ICC 0.82-0.97) and good inter-rater reliabilities (ICC 0.78 and 0.82). Overlaps of intra- and inter-rater runs were very good (≥ 89.7%). We present a fast, semi-automated method for in vivo hypothalamus volumetry in 3 Tesla MRI. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Reproducibility of repeated measurements with the Kikuhime pressure sensor under pressure garments in burn scar treatment.

    PubMed

    Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke

    2007-08-01

    This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.

  20. Thoracic limb alignment in healthy labrador retrievers: evaluation of standing versus recumbent frontal plane radiography.

    PubMed

    Goodrich, Zachary J; Norby, Bo; Eichelberger, Bunita M; Friedeck, Wade O; Callis, Hollye N; Hulse, Don A; Kerwin, Sharon C; Fox, Derek B; Saunders, W Brian

    2014-10-01

    To report thoracic limb alignment values in healthy dogs; to determine if limb alignment values are significantly different when obtained from standing versus recumbent radiographic projections. Prospective cross-sectional study. Labrador Retrievers (n = 45) >15 months of age. Standing and recumbent radiographs were obtained and limb montages were randomized before analysis by a single investigator blinded to dog, limb, and limb position. Twelve limb alignment values were determined using the CORA methodology. Measurements were performed in triplicate and intra-observer variability was evaluated by intra-class correlation coefficient (ICC). Limb alignment values were reported as mean ± SD and 95% confidence intervals. Linear mixed models were used to determine if significant associations existed between limb alignment values and limb, limb position, gender, age, weight, and body condition score. There were significant differences in standing and recumbent limb alignment values for all values except elbow mechanical axis deviation (eMAD). Limb, gender, age, body weight, and body condition score had no effect. ICC values ranged from 0.522 to 0.758, indicating moderate to substantial agreement for repeated measurements by a single investigator. Limb alignment values are significantly different when determined from standing versus recumbent radiographs in healthy Labrador Retrievers. © Copyright 2014 by The American College of Veterinary Surgeons.

  1. Deep Correlated Holistic Metric Learning for Sketch-Based 3D Shape Retrieval.

    PubMed

    Dai, Guoxian; Xie, Jin; Fang, Yi

    2018-07-01

    How to effectively retrieve desired 3D models with simple queries is a long-standing problem in computer vision community. The model-based approach is quite straightforward but nontrivial, since people could not always have the desired 3D query model available by side. Recently, large amounts of wide-screen electronic devices are prevail in our daily lives, which makes the sketch-based 3D shape retrieval a promising candidate due to its simpleness and efficiency. The main challenge of sketch-based approach is the huge modality gap between sketch and 3D shape. In this paper, we proposed a novel deep correlated holistic metric learning (DCHML) method to mitigate the discrepancy between sketch and 3D shape domains. The proposed DCHML trains two distinct deep neural networks (one for each domain) jointly, which learns two deep nonlinear transformations to map features from both domains into a new feature space. The proposed loss, including discriminative loss and correlation loss, aims to increase the discrimination of features within each domain as well as the correlation between different domains. In the new feature space, the discriminative loss minimizes the intra-class distance of the deep transformed features and maximizes the inter-class distance of the deep transformed features to a large margin within each domain, while the correlation loss focused on mitigating the distribution discrepancy across different domains. Different from existing deep metric learning methods only with loss at the output layer, our proposed DCHML is trained with loss at both hidden layer and output layer to further improve the performance by encouraging features in the hidden layer also with desired properties. Our proposed method is evaluated on three benchmarks, including 3D Shape Retrieval Contest 2013, 2014, and 2016 benchmarks, and the experimental results demonstrate the superiority of our proposed method over the state-of-the-art methods.

  2. Rad52 competes with Ku70/Ku86 for binding to S-region DSB ends to modulate antibody class-switch DNA recombination

    PubMed Central

    Zan, Hong; Tat, Connie; Qiu, Zhifang; Taylor, Julia R.; Guerrero, Justin A.; Shen, Tian; Casali, Paolo

    2017-01-01

    Antibody class-switch DNA recombination (CSR) is initiated by AID-introduced DSBs in the switch (S) regions targeted for recombination, as effected by Ku70/Ku86-mediated NHEJ. Ku-deficient B cells, however, undergo (reduced) CSR through an alternative(A)-NHEJ pathway, which introduces microhomologies in S–S junctions. As microhomology-mediated end-joining requires annealing of single-strand DNA ends, we addressed the contribution of single-strand annealing factors HR Rad52 and translesion DNA polymerase θ to CSR. Compared with their Rad52+/+ counterparts, which display normal CSR, Rad52−/− B cells show increased CSR, fewer intra-Sμ region recombinations, no/minimal microhomologies in S–S junctions, decreased c-Myc/IgH translocations and increased Ku70/Ku86 recruitment to S-region DSB ends. Rad52 competes with Ku70/Ku86 for binding to S-region DSB ends. It also facilitates a Ku-independent DSB repair, which favours intra-S region recombination and mediates, particularly in Ku absence, inter-S–S recombination, as emphasized by the significantly greater CSR reduction in Rad52−/− versus Rad52+/+ B cells on Ku86 knockdown. PMID:28176781

  3. Rad52 competes with Ku70/Ku86 for binding to S-region DSB ends to modulate antibody class-switch DNA recombination.

    PubMed

    Zan, Hong; Tat, Connie; Qiu, Zhifang; Taylor, Julia R; Guerrero, Justin A; Shen, Tian; Casali, Paolo

    2017-02-08

    Antibody class-switch DNA recombination (CSR) is initiated by AID-introduced DSBs in the switch (S) regions targeted for recombination, as effected by Ku70/Ku86-mediated NHEJ. Ku-deficient B cells, however, undergo (reduced) CSR through an alternative(A)-NHEJ pathway, which introduces microhomologies in S-S junctions. As microhomology-mediated end-joining requires annealing of single-strand DNA ends, we addressed the contribution of single-strand annealing factors HR Rad52 and translesion DNA polymerase θ to CSR. Compared with their Rad52 +/+ counterparts, which display normal CSR, Rad52 -/- B cells show increased CSR, fewer intra-Sμ region recombinations, no/minimal microhomologies in S-S junctions, decreased c-Myc/IgH translocations and increased Ku70/Ku86 recruitment to S-region DSB ends. Rad52 competes with Ku70/Ku86 for binding to S-region DSB ends. It also facilitates a Ku-independent DSB repair, which favours intra-S region recombination and mediates, particularly in Ku absence, inter-S-S recombination, as emphasized by the significantly greater CSR reduction in Rad52 -/- versus Rad52 +/+ B cells on Ku86 knockdown.

  4. On the teleconnection patterns to precipitation in the eastern Tianshan Mountains, China

    NASA Astrophysics Data System (ADS)

    Zhong, Yu; Wang, Binbin; Zou, Chris B.; Hu, Bill X.; Liu, Youcun; Hao, Yonghong

    2017-11-01

    The Tianshan Mountains are known as the "water tower" in the arid region of Central Asia. Change in precipitation amount and pattern can have a profound impact on regional civilization and life supporting ecosystems. For this study, a systematic analysis of long-term precipitation data for the eastern Tianshan Mountains was conducted to investigate the influence of climate teleconnections on annual and intra-annual precipitation using data collected between 1951 and 2014 from 39 meteorological stations. Annual precipitation has increased during the past six decades at an average rate of 6.7 mm/10 years largely due to the increase in precipitation during the intra-annual wet period (May-October). The annual precipitation and its rate of increase were higher in the northwestern region. Annual precipitation was found to be most strongly correlated with index of Indian Summer Monsoon (ISM), and partially correlated with indices of Pacific Decadal Oscillation (PDO), Pacific North American Teleconnection Pattern (PNA), Arctic Oscillation (AO), El Nino-Southern Oscillation (ENSO), and North Atlantic Oscillation (NAO). ISM was positively correlated with the precipitation in almost the entire region during the intra-annual wet period, while it showed positive correlations in the northern slope and the alpine region, and negative correlations in the southern slope during the intra-annual dry period (November to April). PDO had much weaker influence both in spatial scale and strength and primarily affected low elevations on the southern slopes of the middle and western regions. The impacts of PNA and AO on precipitation were weak and localized. ENSO and NAO indices were almost not correlated with annual precipitation observation in the eastern Tianshan Mountains.

  5. Novel modes and adaptive block scanning order for intra prediction in AV1

    NASA Astrophysics Data System (ADS)

    Hadar, Ofer; Shleifer, Ariel; Mukherjee, Debargha; Joshi, Urvang; Mazar, Itai; Yuzvinsky, Michael; Tavor, Nitzan; Itzhak, Nati; Birman, Raz

    2017-09-01

    The demand for streaming video content is on the rise and growing exponentially. Networks bandwidth is very costly and therefore there is a constant effort to improve video compression rates and enable the sending of reduced data volumes while retaining quality of experience (QoE). One basic feature that utilizes the spatial correlation of pixels for video compression is Intra-Prediction, which determines the codec's compression efficiency. Intra prediction enables significant reduction of the Intra-Frame (I frame) size and, therefore, contributes to efficient exploitation of bandwidth. In this presentation, we propose new Intra-Prediction algorithms that improve the AV1 prediction model and provide better compression ratios. Two (2) types of methods are considered: )1( New scanning order method that maximizes spatial correlation in order to reduce prediction error; and )2( New Intra-Prediction modes implementation in AVI. Modern video coding standards, including AVI codec, utilize fixed scan orders in processing blocks during intra coding. The fixed scan orders typically result in residual blocks with high prediction error mainly in blocks with edges. This means that the fixed scan orders cannot fully exploit the content-adaptive spatial correlations between adjacent blocks, thus the bitrate after compression tends to be large. To reduce the bitrate induced by inaccurate intra prediction, the proposed approach adaptively chooses the scanning order of blocks according to criteria of firstly predicting blocks with maximum number of surrounding, already Inter-Predicted blocks. Using the modified scanning order method and the new modes has reduced the MSE by up to five (5) times when compared to conventional TM mode / Raster scan and up to two (2) times when compared to conventional CALIC mode / Raster scan, depending on the image characteristics (which determines the percentage of blocks predicted with Inter-Prediction, which in turn impacts the efficiency of the new scanning method). For the same cases, the PSNR was shown to improve by up to 7.4dB and up to 4 dB, respectively. The new modes have yielded 5% improvement in BD-Rate over traditionally used modes, when run on K-Frame, which is expected to yield 1% of overall improvement.

  6. Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

    PubMed

    Fujishiro, Takaaki; Hayashi, Shinya; Kanzaki, Noriyuki; Hashimoto, Shingo; Shibanuma, Nao; Kurosaka, Masahiro

    2014-06-01

    The use of screws can enhance immediate cup fixation, but the influence of screw insertion on cup position has not previously been measured. The purpose of this study was to quantitatively evaluate the effect of intra-operative screw fixation on acetabular component alignment that has been inserted with the use of a navigation system. We used a navigation system to measure cup alignment at the time of press-fit and after screw fixation in 144 hips undergoing total hip arthroplasty. We also compared those findings with factors measured from postoperative radiographs. The mean intra-operative change of cup position was 1.78° for inclination and 1.81° for anteversion. The intra-operative change of anteversion correlated with the number of screws. The intra-operative change of inclination also correlated with medial hip centre. The insertion of screws can induce changes in cup alignment, especially when multiple screws are used or if a more medial hip centre is required for rigid acetabular fixation.

  7. NAViGaTing the Micronome – Using Multiple MicroRNA Prediction Databases to Identify Signalling Pathway-Associated MicroRNAs

    PubMed Central

    Shirdel, Elize A.; Xie, Wing; Mak, Tak W.; Jurisica, Igor

    2011-01-01

    Background MicroRNAs are a class of small RNAs known to regulate gene expression at the transcript level, the protein level, or both. Since microRNA binding is sequence-based but possibly structure-specific, work in this area has resulted in multiple databases storing predicted microRNA:target relationships computed using diverse algorithms. We integrate prediction databases, compare predictions to in vitro data, and use cross-database predictions to model the microRNA:transcript interactome – referred to as the micronome – to study microRNA involvement in well-known signalling pathways as well as associations with disease. We make this data freely available with a flexible user interface as our microRNA Data Integration Portal — mirDIP (http://ophid.utoronto.ca/mirDIP). Results mirDIP integrates prediction databases to elucidate accurate microRNA:target relationships. Using NAViGaTOR to produce interaction networks implicating microRNAs in literature-based, KEGG-based and Reactome-based pathways, we find these signalling pathway networks have significantly more microRNA involvement compared to chance (p<0.05), suggesting microRNAs co-target many genes in a given pathway. Further examination of the micronome shows two distinct classes of microRNAs; universe microRNAs, which are involved in many signalling pathways; and intra-pathway microRNAs, which target multiple genes within one signalling pathway. We find universe microRNAs to have more targets (p<0.0001), to be more studied (p<0.0002), and to have higher degree in the KEGG cancer pathway (p<0.0001), compared to intra-pathway microRNAs. Conclusions Our pathway-based analysis of mirDIP data suggests microRNAs are involved in intra-pathway signalling. We identify two distinct classes of microRNAs, suggesting a hierarchical organization of microRNAs co-targeting genes both within and between pathways, and implying differential involvement of universe and intra-pathway microRNAs at the disease level. PMID:21364759

  8. Testing Group Mean Differences of Latent Variables in Multilevel Data Using Multiple-Group Multilevel CFA and Multilevel MIMIC Modeling.

    PubMed

    Kim, Eun Sook; Cao, Chunhua

    2015-01-01

    Considering that group comparisons are common in social science, we examined two latent group mean testing methods when groups of interest were either at the between or within level of multilevel data: multiple-group multilevel confirmatory factor analysis (MG ML CFA) and multilevel multiple-indicators multiple-causes modeling (ML MIMIC). The performance of these methods were investigated through three Monte Carlo studies. In Studies 1 and 2, either factor variances or residual variances were manipulated to be heterogeneous between groups. In Study 3, which focused on within-level multiple-group analysis, six different model specifications were considered depending on how to model the intra-class group correlation (i.e., correlation between random effect factors for groups within cluster). The results of simulations generally supported the adequacy of MG ML CFA and ML MIMIC for multiple-group analysis with multilevel data. The two methods did not show any notable difference in the latent group mean testing across three studies. Finally, a demonstration with real data and guidelines in selecting an appropriate approach to multilevel multiple-group analysis are provided.

  9. Cross-cultural adaptation and validation to Brazil of the Obesity-related Problems Scale

    PubMed Central

    Brasil, Andreia Mara Brolezzi; Brasil, Fábio; Maurício, Angélica Aparecida; Vilela, Regina Maria

    2017-01-01

    ABSTRACT Objective To validate a reliable version of the Obesity-related Problems Scale in Portuguese to use it in Brazil. Methods The Obesity-related Problems Scale was translated and transculturally adapted. Later it was simultaneously self-applied with a 12-item version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0), to 50 obese patients and 50 non-obese individuals, and applied again to half of them after 14 days. Results The Obesity-related Problems scale was able to differentiate obese from non-obese individuals with higher accuracy than WHODAS 2.0, correlating with this scale and with body mass index. The factor analysis determined a two-dimensional structure, which was confirmed with χ2/df=1.81, SRMR=0.05, and CFI=0.97. The general a coefficient was 0.90 and the inter-item intra-class correlation, in the reapplication, ranged from 0.75 to 0.87. Conclusion The scale proved to be valid and reliable for use in the Brazilian population, without the need to exclude items. PMID:29091155

  10. Gene-dietary fat interaction, bone mineral density and bone speed of sound in Children: a twin study in China

    PubMed Central

    Huang, Tao; Liu, Huijuan; Zhao, Wei; Li, Ji; Wang, Youfa

    2015-01-01

    Scope Dietary fat correlates with bone mineral density (BMD). We tested the association between fat intake and BMD, and tested if fat intake modified the degree of genetic influence on BMD and bone speed of sound (SOS). Methods and results We included 622 twins aged 7–15 y from South China. Data on anthropometry, dietary intake, BMD, and SOS were collected. Quantitative genetic analyses of structural equation models were fit using the Mx statistical package. The within-pair intra-class correlations (ICC) for BMD in DZ twins were nearly half of that for MZ twins (ICC=0.39 vs 0.70). The heritability of BMD and SOS were 71% and 79%. Phenotypic correlation between fat intake and SOS was significant (r=−0.19, p=0.04). SOS was negatively correlated with fat intake in boys (r=−0.11, p=0.05), but not in girls. Full Cholesky decomposition models showed SOS has a strong genetic correlation with fat intake (rA =−0.88, 95% CI=−0.94, 0.01); the environmental correlation between fat intake and SOS was weak (rE =−0.04, 95% CI=−0.20, 0.13). Fat intake modified the additive genetic effects on BMD. Conclusion Genetic factors explained 71% and 79% of individual variance in BMD and SOS, respectively. Low fat intake counteracts genetic predisposition to low BMD. PMID:25546604

  11. Comparison of patient evaluations of health care quality in relation to WHO measures of achievement in 12 European countries.

    PubMed

    Kerssens, Jan J; Groenewegen, Peter P; Sixma, Herman J; Boerma, Wienke G W; van der Eijk, Ingrid

    2004-02-01

    To gain insight into similarities and differences in patient evaluations of quality of primary care across 12 European countries and to correlate patient evaluations with WHO health system performance measures (for example, responsiveness) of these countries. Patient evaluations were derived from a series of Quote (QUality of care Through patients' Eyes) instruments designed to measure the quality of primary care. Various research groups provided a total sample of 5133 patients from 12 countries: Belarus, Denmark, Finland, Greece, Ireland, Israel, Italy, the Netherlands, Norway, Portugal, United Kingdom, and Ukraine. Intraclass correlations of 10 Quote items were calculated to measure differences between countries. The world health report 2000 - Health systems: improving performance performance measures in the same countries were correlated with mean Quote scores. Intra-class correlation coefficients ranged from low to very high, which indicated little variation between countries in some respects (for example, primary care providers have a good understanding of patients' problems in all countries) and large variation in other respects (for example, with respect to prescription of medication and communication between primary care providers). Most correlations between mean Quote scores per country and WHO performance measures were positive. The highest correlation (0.86) was between the primary care provider's understanding of patients' problems and responsiveness according to WHO. Patient evaluations of the quality of primary care showed large differences across countries and related positively to WHO's performance measures of health care systems.

  12. Discriminative region extraction and feature selection based on the combination of SURF and saliency

    NASA Astrophysics Data System (ADS)

    Deng, Li; Wang, Chunhong; Rao, Changhui

    2011-08-01

    The objective of this paper is to provide a possible optimization on salient region algorithm, which is extensively used in recognizing and learning object categories. Salient region algorithm owns the superiority of intra-class tolerance, global score of features and automatically prominent scale selection under certain range. However, the major limitation behaves on performance, and that is what we attempt to improve. By reducing the number of pixels involved in saliency calculation, it can be accelerated. We use interest points detected by fast-Hessian, the detector of SURF, as the candidate feature for saliency operation, rather than the whole set in image. This implementation is thereby called Saliency based Optimization over SURF (SOSU for short). Experiment shows that bringing in of such a fast detector significantly speeds up the algorithm. Meanwhile, Robustness of intra-class diversity ensures object recognition accuracy.

  13. PubMed Central

    FARNETI, D.; FATTORI, B.; NACCI, A.; MANCINI, V.; SIMONELLI, M.; RUOPPOLO, G.; GENOVESE, E.

    2014-01-01

    SUMMARY This study evaluated the intra- and inter-rater reliability of the Pooling score (P-score) in clinical endoscopic evaluation of severity of swallowing disorder, considering excess residue in the pharynx and larynx. The score (minimum 4 - maximum 11) is obtained by the sum of the scores given to the site of the bolus, the amount and ability to control residue/bolus pooling, the latter assessed on the basis of cough, raclage, number of dry voluntary or reflex swallowing acts (< 2, 2-5, > 5). Four judges evaluated 30 short films of pharyngeal transit of 10 solid (1/4 of a cracker), 11 creamy (1 tablespoon of jam) and 9 liquid (1 tablespoon of 5 cc of water coloured with methlyene blue, 1 ml in 100 ml) boluses in 23 subjects (10 M/13 F, age from 31 to 76 yrs, mean age 58.56±11.76 years) with different pathologies. The films were randomly distributed on two CDs, which differed in terms of the sequence of the films, and were given to judges (after an explanatory session) at time 0, 24 hours later (time 1) and after 7 days (time 2). The inter- and intra-rater reliability of the P-score was calculated using the intra-class correlation coefficient (ICC; 3,k). The possibility that consistency of boluses could affect the scoring of the films was considered. The ICC for site, amount, management and the P-score total was found to be, respectively, 0.999, 0.997, 1.00 and 0.999. Clinical evaluation of a criterion of severity of a swallowing disorder remains a crucial point in the management of patients with pathologies that predispose to complications. The P-score, derived from static and dynamic parameters, yielded a very high correlation among the scores attributed by the four judges during observations carried out at different times. Bolus consistencies did not affect the outcome of the test: the analysis of variance, performed to verify if the scores attributed by the four judges to the parameters selected, might be influenced by the different consistencies of the boluses, was not significant. These initial data validate the clinical use of the P-score in the management of patients with deglutition disorders by a multidisciplinary team. PMID:24843220

  14. Development and validation of a Malawian version of the primary care assessment tool.

    PubMed

    Dullie, Luckson; Meland, Eivind; Hetlevik, Øystein; Mildestvedt, Thomas; Gjesdal, Sturla

    2018-05-16

    Malawi does not have validated tools for assessing primary care performance from patients' experience. The aim of this study was to develop a Malawian version of Primary Care Assessment Tool (PCAT-Mw) and to evaluate its reliability and validity in the assessment of the core primary care dimensions from adult patients' perspective in Malawi. A team of experts assessed the South African version of the primary care assessment tool (ZA-PCAT) for face and content validity. The adapted questionnaire underwent forward and backward translation and a pilot study. The tool was then used in an interviewer administered cross-sectional survey in Neno district, Malawi, to test validity and reliability. Exploratory factor analysis was performed on a random half of the sample to evaluate internal consistency, reliability and construct validity of items and scales. The identified constructs were then tested with confirmatory factor analysis. Likert scale assumption testing and descriptive statistics were done on the final factor structure. The PCAT-Mw was further tested for intra-rater and inter-rater reliability. From the responses of 631 patients, a 29-item PCAT-Mw was constructed comprising seven multi-item scales, representing five primary care dimensions (first contact, continuity, comprehensiveness, coordination and community orientation). All the seven scales achieved good internal consistency, item-total correlations and construct validity. Cronbach's alpha coefficient ranged from 0.66 to 0.91. A satisfactory goodness of fit model was achieved (GFI = 0.90, CFI = 0.91, RMSEA = 0.05, PCLOSE = 0.65). The full range of possible scores was observed for all scales. Scaling assumptions tests were achieved for all except the two comprehensiveness scales. Intra-class correlation coefficient (ICC) was 0.90 (n = 44, 95% CI 0.81-0.94, p < 0.001) for intra-rater reliability and 0.84 (n = 42, 95% CI 0.71-0.96, p < 0.001) for inter-rater reliability. Comprehensive metric analyses supported the reliability and validity of PCAT-Mw in assessing the core concepts of primary care from adult patients' experience. This tool could be used for health service research in primary care in Malawi.

  15. Intra-familial aggregation and heritability of aortic versus brachial pulse pressure after imputing pretreatment values in a community of African ancestry.

    PubMed

    Redelinghuys, Michelle; Norton, Gavin R; Maseko, Muzi J; Majane, Olebogeng H I; Woodiwiss, Angela J

    2012-06-01

    To compare the intra-familial aggregation and heritability of central (aortic) (PPc) versus peripheral (brachial) (PPp) pulse pressure after imputing pretreatment blood pressures (BPs) in treated participants in a community of black African ancestry. Central PPc [generalized transfer function (GTF) and radial P2-derived] was determined with applanation tonometry at the radial artery (SphygmoCor software) in 946 participants from 258 families with 23 families including three generations from an urban developing community of black Africans. In the 24.1% of participants receiving antihypertensive treatment, pretreatment brachial BP was imputed from published overall averaged effects of therapy grouped by class and dose, specific for groups of black African descent. From these data PPc was estimated from proportionate differences in central aortic and brachial PP. Heritability estimates were determined from SAGE software. Echocardiography was evaluated in 507 participants in order to determine stroke volume. With adjustments for confounders, parent-child (P < 0.05) and sibling-sibling (P < 0.0005) correlations were noted for log PPc, whilst for log PPp only sibling-sibling correlations were noted. No mother-father correlations were noted for either PPc or PPp. Independent of confounders the heritability for log GTF-derived (h = 0.33 ± 0.07, P < 0.0001) and P2-derived (h = 0.30 ± 0.07, P < 0.0001) PPc was greater than the heritability for log PPp (h = 0.11 ± 0.06, P < 0.05) (P < 0.05 for comparison of heritability estimates). After imputing pretreatment BP values, central aortic PP is significantly more inherited than brachial PP. These data suggest that in groups of African descent the genetic determinants of PP may be underestimated when employing brachial rather than central aortic PP measurements.

  16. [Characteristics of high resolution diffusion weighted imaging apparent diffusion coefficient histogram and its correlations with cancer stages in patients with nasopharyngeal carcinoma].

    PubMed

    Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L

    2017-11-07

    Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (<305 voxels, about 2 cm(3)) and large cancer group (≥2 cm(3)). The correlation between ADC histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P <0.05). There were significant differences in tumor voxels among patients with different T stages ( K =22.306, P <0.05). There were significant differences in the ADC(mean), ADC(25%), ADC(50%) among patients with different T stages in the small cancer group( K =8.409, 8.187, 8.699, all P <0.05), and the up-mentioned three indices were positively correlated with T staging ( r =0.221, 0.209, 0.235, all P <0.05). Skewness and kurtosis differed significantly between the groups with different cancer volume( t =-2.987, Z =-3.770, both P <0.05). Conclusion: The tumor volume, tissue uniformity of NPC are important factors affecting ADC and cancer stages, parameters of ADC histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).

  17. A single CT for attenuation correction of both rest and stress SPECT myocardial perfusion imaging: a retrospective feasibility study

    PubMed Central

    Ahlman, Mark A; Nietert, Paul J; Wahlquist, Amy E; Serguson, Jill M; Berry, Max W; Suranyi, Pal; Liu, Songtao; Spicer, Kenneth M

    2014-01-01

    Purpose: In the effort to reduce radiation exposure to patients undergoing myocardial perfusion imaging (MPI) with SPECT/CT, we evaluate the feasibility of a single CT for attenuation correction (AC) of single-day rest (R)/stress (S) perfusion. Methods: Processing of 20 single isotope and 20 dual isotope MPI with perfusion defects were retrospectively repeated in three steps: (1) the standard method using a concurrent R-CT for AC of R-SPECT and S-CT for S-SPECT; (2) the standard method repeated; and (3) with the R-CT used for AC of S-SPECT, and the S-CT used for AC of R-SPECT. Intra-Class Correlation Coefficients (ICC) and Choen’s kappa were used to measure intra-operator variability in sum scoring. Results: The highest level of intra-operator reliability was seen with the reproduction of the sum rest score (SRS) and sum stress score (SSS) (ICC > 95%). ICCs were > 85% for SRS and SSS when alternate CTs were used for AC, but when sum difference scores were calculated, ICC values were much lower (~22% to 27%), which may imply that neither CT substitution resulted in a reproducible difference score. Similar results were seen when evaluating dichotomous outcomes (sum scores difference of ≥ 4) when comparing different processing techniques (kappas ~0.32 to 0.43). Conclusions: When a single CT is used for AC of both rest and stress SPECT, there is disproportionately high variability in sum scoring that is independent of user error. This information can be used to direct further investigation in radiation reduction for common imaging exams in nuclear medicine. PMID:24482701

  18. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT.

    PubMed

    Ciet, Pierluigi; Serra, Goffredo; Bertolo, Silvia; Spronk, Sandra; Ros, Mirco; Fraioli, Francesco; Quattrucci, Serena; Assael, M Baroukh; Catalano, Carlo; Pomerri, Fabio; Tiddens, Harm A W M; Morana, Giovanni

    2016-03-01

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100% (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). PROPELLER MRI does not match CT sensitivity to assess CF lung disease. PROPELLER MRI has lower sensitivity than CT to detect severe bronchiectasis. PROPELLER MRI has good to very good intra- and inter-observer variability. PROPELLER MRI can be used for short-term follow-up studies in CF.

  19. The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.

    PubMed

    Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell

    2016-04-01

    Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC < 0.2). Intra-rater reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC < 0.6). The Sn-N, N-M, and BW measurements are very reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  20. 2D phase sensitive inversion recovery imaging to measure in-vivo spinal cord gray and white matter areas in clinically feasible acquisition times

    PubMed Central

    Papinutto, N.; Schlaeger, R.; Panara, V.; Caverzasi, E.; Ahn, S.; Johnson, K.J.; Zhu, A.H.; Stern, W.A.; Laub, G.; Hauser, S.L.; Henry, R.G.

    2018-01-01

    PURPOSE In-vivo assessment of spinal cord gray matter (GM) and white matter (WM) could become pivotal to study various neurological diseases, but it is challenging because of insufficient GM/WM contrast provided by conventional MRI. Here we present and assess a procedure for measurement of spinal cord total cross-sectional area (TCA) and GM areas based on phase sensitive inversion recovery imaging (PSIR). MATERIALS AND METHODS We acquired 2D PSIR images at 3T at each disc level of the spinal axis on 10 healthy subjects and measured TCA, cord diameters, WM and GM area, and GM area/TCA ratio. We secondly investigated 32 healthy subjects at 4 selected levels (C2–C3, C3–C4, T8–T9, T9–T10, total acquisition time <8 minutes) and generated normative reference values of TCA and GM areas. We assessed test-retest, intra- and inter-operator reliability of the acquisition strategy and measurement steps. RESULTS The measurement procedure based on 2D PSIR imaging allowed TCA and GM area assessments along the entire spinal cord axis. The tests we performed revealed high test-retest/intra-operator reliability (mean coefficient of variation (COV) at C2–C3: TCA=0.41%, GM area=2.75%) and inter-operator reliability of the measurements (mean COV on the 4 levels: TCA=0.44%, GM area= 4.20%; mean intra-class correlation coefficient: TCA=0.998, GM area=0.906). CONCLUSION 2D PSIR allows reliable in-vivo assessment of spinal cord TCA, GM and WM areas in clinically feasible acquisition times. The area measurements presented here are in agreement with previous MRI and post-mortem studies. PMID:25483607

  1. [Validation of a questionnaire to assess the quality of health information in Argentinian newspapers].

    PubMed

    Biondo, Emiliano; Khoury, Marina Claudia

    2005-09-01

    The daily press is an important source of health information and may influence health care utilization. However, medical reports published in newspapers from developed countries have shown a poor quality. The reliability of the questionnaire Index of Scientific Quality was evaluated by using it to measure the scientific quality of health information published by Argentinian newspapers between 2000 and 2002. It assessed the readability of the texts in grade levels and explored the relationship between quality and other factors. The Spanish adaptation of the instrument consisted in translation, back-traslation and pilot study. The reliability was assessed by applying the instrument to newspaper articles with more than 300 words that discussed therapy, diagnosis, prevention, lifestyle effects, and hazardous exposure. Two physicians independently graded 129 articles. Inter-observer and intra-observer concordance was quantified for each item with the intra-class correlation coefficient (CI95%). To measure scientific quality, a randomized sample of 210 articles was assessed. Each received a mark that ranged from 0 to 100. Readability was determined by the FRY graph method. The relationship between quality and other variables was explored with multiple linear regression analysis. The inter-rater concordance varied between 0.48 (0.34-0.61) and 0.67 (0.56-0.75). Intra-rater concordance varied from 0.51 (0.37-0.63) to 0.95 (0.93-0.96). The internal consistency (Cronbach's alpha) was 0.88. The quality-of-health-information was rated at 25 points (16.7, 33.3) [median (intercuartil range)]. The reading level was assessed to be at the 10.4 grade (10.2-10.6) [mean (CI 95%)]. Quality of the health information was greatly deficient; however, no specific factors were related with quality. Readability was probably a key barrier for access to the health information.

  2. Reliability of Untrained and Experienced Raters on FEES: Rating Overall Residue is a Simple Task.

    PubMed

    Pisegna, Jessica M; Borders, James C; Kaneoka, Asako; Coster, Wendy J; Leonard, Rebecca; Langmore, Susan E

    2018-03-07

    The purpose of this study was to investigate the reliability of residue ratings on Fiberoptic Endoscopic Evaluation of Swallowing (FEES). We also examined rating differences based on experience to determine if years of experience influenced residue ratings. A group of 44 raters watched 81 FEES videos representing a wide range of residue severities for thin liquid, applesauce, and cracker boluses. Raters were untrained on the rating scales and simply rated their overall impression of residue amount on a visual analog scale (VAS) and a five-point ordinal scale in a randomized fashion across two sessions. Intra-class correlation coefficients, kappa coefficients, and ANOVAs were used to analyze agreement and differences in ratings. Residue ratings on both the VAS and ordinal scales had acceptable inter- and intra-rater reliability. Inter-rater agreement was acceptable (ICC > 0.7) for all comparisons. Intra-rater agreement was excellent on the VAS scale (r c  = 0.9) and good on the ordinal scale (k = 0.78). There was no significant difference between expert ratings and other raters based on years of experience for cracker ratings (p = 0.2119) and applesauce ratings (p = 0.2899), but there was a significant difference between clinicians on thin liquid ratings (p = 0.0005). Without any specific training, raters demonstrated high reliability when rating the overall amount of residue on FEES. Years of experience with FEES did not influence residue ratings, suggesting that expert ratings of overall residue amount are not unique or specialized. Rating the overall amount of residue on FEES appears to be a simple visual-perceptual task for puree and cracker boluses.

  3. Anthropometric Study of Three-Dimensional Facial Morphology in Malay Adults

    PubMed Central

    Majawit, Lynnora Patrick; Mohd Razi, Roziana

    2016-01-01

    Objectives To establish the three-dimensional (3D) facial soft tissue morphology of adult Malaysian subjects of the Malay ethnic group; and to determine the morphological differences between the genders, using a non-invasive stereo-photogrammetry 3D camera. Material and Methods One hundred and nine subjects participated in this research, 54 Malay men and 55 Malay women, aged 20–30 years old with healthy BMI and with no adverse skeletal deviation. Twenty-three facial landmarks were identified on 3D facial images captured using a VECTRA M5-360 Head System (Canfield Scientific Inc, USA). Two angular, 3 ratio and 17 linear measurements were identified using Canfield Mirror imaging software. Intra- and inter-examiner reliability tests were carried out using 10 randomly selected images, analyzed using the intra-class correlation coefficient (ICC). Multivariate analysis of variance (MANOVA) was carried out to investigate morphologic differences between genders. Results ICC scores were generally good for both intra-examiner (range 0.827–0.987) and inter-examiner reliability (range 0.700–0.983) tests. Generally, all facial measurements were larger in men than women, except the facial profile angle which was larger in women. Clinically significant gender dimorphisms existed in biocular width, nose height, nasal bridge length, face height and lower face height values (mean difference > 3mm). Clinical significance was set at 3mm. Conclusion Facial soft tissue morphological values can be gathered efficiently and measured effectively from images captured by a non-invasive stereo-photogrammetry 3D camera. Adult men in Malaysia when compared to women had a wider distance between the eyes, a longer and more prominent nose and a longer face. PMID:27706220

  4. Reliability of Semi-Automated Segmentations in Glioblastoma.

    PubMed

    Huber, T; Alber, G; Bette, S; Boeckh-Behrens, T; Gempt, J; Ringel, F; Alberts, E; Zimmer, C; Bauer, J S

    2017-06-01

    In glioblastoma, quantitative volumetric measurements of contrast-enhancing or fluid-attenuated inversion recovery (FLAIR) hyperintense tumor compartments are needed for an objective assessment of therapy response. The aim of this study was to evaluate the reliability of a semi-automated, region-growing segmentation tool for determining tumor volume in patients with glioblastoma among different users of the software. A total of 320 segmentations of tumor-associated FLAIR changes and contrast-enhancing tumor tissue were performed by different raters (neuroradiologists, medical students, and volunteers). All patients underwent high-resolution magnetic resonance imaging including a 3D-FLAIR and a 3D-MPRage sequence. Segmentations were done using a semi-automated, region-growing segmentation tool. Intra- and inter-rater-reliability were addressed by intra-class-correlation (ICC). Root-mean-square error (RMSE) was used to determine the precision error. Dice score was calculated to measure the overlap between segmentations. Semi-automated segmentation showed a high ICC (> 0.985) for all groups indicating an excellent intra- and inter-rater-reliability. Significant smaller precision errors and higher Dice scores were observed for FLAIR segmentations compared with segmentations of contrast-enhancement. Single rater segmentations showed the lowest RMSE for FLAIR of 3.3 % (MPRage: 8.2 %). Both, single raters and neuroradiologists had the lowest precision error for longitudinal evaluation of FLAIR changes. Semi-automated volumetry of glioblastoma was reliably performed by all groups of raters, even without neuroradiologic expertise. Interestingly, segmentations of tumor-associated FLAIR changes were more reliable than segmentations of contrast enhancement. In longitudinal evaluations, an experienced rater can detect progressive FLAIR changes of less than 15 % reliably in a quantitative way which could help to detect progressive disease earlier.

  5. Validation (in Spanish) of the Mini Nutritional Assessment survey to assess the nutritional status of patients over 65 years of age.

    PubMed

    Muñoz Díaz, Belén; Molina-Recio, Guillermo; Romero-Saldaña, Manuel; Redondo Sánchez, Juana; Aguado Taberné, Cristina; Arias Blanco, Carmen; Molina-Luque, Rafael; Martínez De La Iglesia, Jorge

    2018-06-05

    To validate the Mini Nutritional Assessment (MNA) in a Spanish population over 65 years of age with varying degrees of independence. This cross-sectional validation study used the Chang nutritional assessment method as a reference test. 248 subjects (75.4% female), with a mean age of 83, completed the study. They were classified into three groups: (i) autonomous patients who were able to take part in activities outside their home; (ii) patients who require help with daily self-care; (iii) patients living in a residential health care facility. . Three health centres and three residential care homes situated in Cordoba (Spain). The kappa values for intra-observer and inter-observer agreement were 0.870 and 0.784, respectively. The intra-class correlation coefficient intra-observer was 0.874 and the inter-observer was 0.789. The sensitivity and specificity readings for the diagnostic accuracy of MNA were 63.2% and 72.9% in the total sample, respectively. The area under the curve was 0.726. For patients in the Group A, B and C, the sensitivity was 89.3%, 60.7% and 18.8%, and the specificity was 23.3%, 56.8% and 94.1%, respectively. The results for the reliability of the survey were excellent, and its internal consistency was acceptable. The diagnostic accuracy, as measured by the sensitivity and specificity readings, was lower than that obtained with the original survey. It can therefore be considered more suitable for a population with limited autonomy, and less appropriate for independent patients. The results may not be relevant to patients outside of the Cordova region in Spain.

  6. Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws.

    PubMed

    Filli, Lukas; Marcon, Magda; Scholz, Bernhard; Calcagni, Maurizio; Finkenstädt, Tim; Andreisek, Gustav; Guggenberger, Roman

    2014-12-01

    The aim of this study was to evaluate a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography (FDCT) of scaphoid fixation screws. FDCT has gained interest in imaging small anatomic structures of the appendicular skeleton. Angiographic C-arm systems with flat detectors allow fluoroscopy and FDCT imaging in a one-stop procedure emphasizing their role as an ideal intraoperative imaging tool. However, FDCT imaging can be significantly impaired by artefacts induced by fixation screws. Following ethical board approval, commercially available scaphoid fixation screws were inserted into six cadaveric specimens in order to fix artificially induced scaphoid fractures. FDCT images corrected with the algorithm were compared to uncorrected images both quantitatively and qualitatively by two independent radiologists in terms of artefacts, screw contour, fracture line visibility, bone visibility, and soft tissue definition. Normal distribution of variables was evaluated using the Kolmogorov-Smirnov test. In case of normal distribution, quantitative variables were compared using paired Student's t tests. The Wilcoxon signed-rank test was used for quantitative variables without normal distribution and all qualitative variables. A p value of < 0.05 was considered to indicate statistically significant differences. Metal artefacts were significantly reduced by the correction algorithm (p < 0.001), and the fracture line was more clearly defined (p < 0.01). The inter-observer reliability was "almost perfect" (intra-class correlation coefficient 0.85, p < 0.001). The prototype correction algorithm in FDCT for metal artefacts induced by scaphoid fixation screws may facilitate intra- and postoperative follow-up imaging. Flat detector computed tomography (FDCT) is a helpful imaging tool for scaphoid fixation. The correction algorithm significantly reduces artefacts in FDCT induced by scaphoid fixation screws. This may facilitate intra- and postoperative follow-up imaging.

  7. Changes in Body Weight and Psychotropic Drugs: A Systematic Synthesis of the Literature

    PubMed Central

    Dent, Robert; Blackmore, Angelique; Peterson, Joan; Habib, Rami; Kay, Gary Peter; Gervais, Alan; Taylor, Valerie; Wells, George

    2012-01-01

    Introduction Psychotropic medication use is associated with weight gain. While there are studies and reviews comparing weight gain for psychotropics within some classes, clinicians frequently use drugs from different classes to treat psychiatric disorders. Objective To undertake a systematic review of all classes of psychotropics to provide an all encompassing evidence-based tool that would allow clinicians to determine the risks of weight gain in making both intra-class and interclass choices of psychotropics. Methodology and Results We developed a novel hierarchical search strategy that made use of systematic reviews that were already available. When such evidence was not available we went on to evaluate randomly controlled trials, followed by cohort and other clinical trials, narrative reviews, and, where necessary, clinical opinion and anecdotal evidence. The data from the publication with the highest level of evidence based on our hierarchical classification was presented. Recommendations from an expert panel supplemented the evidence used to rank these drugs within their respective classes. Approximately 9500 articles were identified in our literature search of which 666 citations were retrieved. We were able to rank most of the psychotropics based on the available evidence and recommendations from subject matter experts. There were few discrepancies between published evidence and the expert panel in ranking these drugs. Conclusion Potential for weight gain is an important consideration in choice of any psychotropic. This tool will help clinicians select psychotropics on a case-by-case basis in order to minimize the impact of weight gain when making both intra-class and interclass choices. PMID:22719834

  8. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in post-menopausal women

    PubMed Central

    Bea, J. W.; Blew, R. M.; Going, S. B.; Hsu, C-H; Lee, M. C.; Lee, V. R.; Caan, B.J.; Kwan, M.L.; Lohman, T. G.

    2016-01-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. Objectives We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Methods Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n=103). ROIs were 1) lumbar vertebrae L2-L4 and 2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and 3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N=25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Results Mean age, BMI and total body fat were: 66.1 ± 4.8y, 25.8 ± 3.8kg/m2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R2: 0.83) and L2-IC (Adj.R2:0.84) abdominal fat (%) well; the adjusted R2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R2: 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat respectively). Conclusions The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in post-menopausal chronic disease risk prediction models. PMID:27416964

  9. Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump.

    PubMed

    Attia, A; Dhahbi, W; Chaouachi, A; Padulo, J; Wong, D P; Chamari, K

    2017-03-01

    Common methods to estimate vertical jump height (VJH) are based on the measurements of flight time (FT) or vertical reaction force. This study aimed to assess the measurement errors when estimating the VJH with flight time using photocell devices in comparison with the gold standard jump height measured by a force plate (FP). The second purpose was to determine the intrinsic reliability of the Optojump photoelectric cells in estimating VJH. For this aim, 20 subjects (age: 22.50±1.24 years) performed maximal vertical jumps in three modalities in randomized order: the squat jump (SJ), counter-movement jump (CMJ), and CMJ with arm swing (CMJarm). Each trial was simultaneously recorded by the FP and Optojump devices. High intra-class correlation coefficients (ICCs) for validity (0.98-0.99) and low limits of agreement (less than 1.4 cm) were found; even a systematic difference in jump height was consistently observed between FT and double integration of force methods (-31% to -27%; p<0.001) and a large effect size (Cohen's d >1.2). Intra-session reliability of Optojump was excellent, with ICCs ranging from 0.98 to 0.99, low coefficients of variation (3.98%), and low standard errors of measurement (0.8 cm). It was concluded that there was a high correlation between the two methods to estimate the vertical jump height, but the FT method cannot replace the gold standard, due to the large systematic bias. According to our results, the equations of each of the three jump modalities were presented in order to obtain a better estimation of the jump height.

  10. Reproduction and vegetative growth in the dioecious shrub Acer barbinerve in temperate forests of Northeast China.

    PubMed

    Wang, Juan; Zhang, Chunyu; Gadow, Klaus V; Cheng, Yanxia; Zhao, Xiuhai

    2015-06-01

    Trade-off in dioecious plant. The trade-off between reproduction, vegetative growth and maintenance is a major issue in the life history of an organism and a record of the process which is producing the largest possible number of living offspring by natural selection. Dioecious species afford an excellent opportunity for detecting such possible trade-offs in resource allocation. In this study, we selected the dioecious shrub Acer barbinerve to examine possible trade-offs between reproduction and vegetative growth in both genders at different modular levels during three successive years. Reproductive and vegetative biomass values were assessed during successive years to evaluate their intra-annual and inter-annual trade-offs. These trade-offs were examined at shoot, branch and shrub modular levels in Acer barbinerve shrubs. An intra-annual trade-off was detected at the shoot level for both genders in 2011 and 2012. Both males and females showed a negative correlation between reproduction and vegetative growth, but this was more prominent in males. For the females of the species, inter-annual trade-offs were only found at branch and shrub levels. Slightly negative correlations in females were detected between the reproduction in 2012 and the reproduction in the two previous years. The gender ratio was significantly male biased during the three successive years of our investigation. Females had higher mortality rates in the larger diameter classes, both in 2011 and 2012. This study revealed a clear trade-off between reproduction and vegetative growth in Acer barbinerve, but results varied between males and females. The degree of autonomy of the different modular levels may affect the ability to detect such trade-offs.

  11. Validation of the Brazilian-Portuguese Version of the Gesture Behavior Test for Patients with Non-Specific Chronic Low Back Pain

    PubMed Central

    Furtado, Ricardo; Jones, Anamaria; Furtado, Rita NV; Jennings, Fábio; Natour, Jamil

    2009-01-01

    OBJECTIVE: To develop a Brazilian version of the gesture behavior test (GBT) for patients with chronic low back pain. METHODS: Translation of GBT into Portuguese was performed by a rheumatologist fluent in the language of origin (French) and skilled in the validation of questionnaires. This translated version was back-translated into French by a native-speaking teacher of the language. The two translators then created a final consensual version in Portuguese. Cultural adaptation was carried out by two rheumatologists, one educated patient and the native-speaking French teacher. Thirty patients with chronic low back pain and fifteen healthcare professionals involved in the education of patients with low back pain through back schools (gold-standard) were evaluated. Reproducibility was initially tested by two observers (inter-observer); the procedures were also videotaped for later evaluation by one of the observers (intra-observer). For construct validation, we compared patients’ scores against the scores of the healthcare professionals. RESULTS: Modifications were made to the GBT for cultural reasons. The Spearman’s correlation coefficient and the intra-class coefficient, which was employed to measure reproducibility, ranged between 0.87 and 0.99 and 0.94 to 0.99, respectively (p < 0.01). With regard to validation, the Mann-Whitney test revealed a significant difference (p < 0.01) between the averages for healthcare professionals (26.60; SD 2.79) and patients (16.30; SD 6.39). There was a positive correlation between the GBT score and the score on the Roland Morris Disability Questionnaire (r= 0.47). CONCLUSIONS: The Brazilian version of the GBT proved to be a reproducible and valid instrument. In addition, according to the questionnaire results, more disabled patients exhibited more protective gesture behavior related to low-back. PMID:19219312

  12. Comparative Analysis of 2-D Versus 3-D Ultrasound Estimation of the Fetal Adrenal Gland Volume and Prediction of Preterm Birth

    PubMed Central

    Turan, Ozhan M.; Turan, Sifa; Buhimschi, Irina A.; Funai, Edmund F.; Campbell, Katherine H.; Bahtiyar, Ozan M.; Harman, Chris R.; Copel, Joshua A.; Baschat, Ahmet A; Buhimschi, Catalin S.

    2013-01-01

    Objective We aim to test the hypothesis that 2D fetal AGV measurements offer similar volume estimates as volume calculations based on 3D technique Methods Fetal AGV was estimated by 3D ultrasound (VOCAL) in 93 women with signs/symptoms of preterm labor and 73 controls. Fetal AGV was calculated using an ellipsoid formula derived from 2D measurements of the same blocks (0.523× length × width × depth). Comparisons were performed by intra-class correlation coefficient (ICC), coefficient of repeatability, and Bland-Altman method. The cAGV (AGV/fetal weight) was calculated for both methods and compared for prediction of PTB within 7 days. Results Among 168 volumes, there was a significant correlation between 3D and 2D methods (ICC=0.979[95%CI: 0.971-0.984]). The coefficient of repeatability for the 3D was superior to the 2D method (Intra-observer 3D: 30.8, 2D:57.6; inter-observer 3D: 12.2, 2D: 15.6). Based on 2D calculations, a cAGV≥433mm3/kg, was best for prediction of PTB (sensitivity: 75%(95%CI=59-87); specificity: 89%(95%CI=82-94). Sensitivity and specificity for the 3D cAGV (cut-off ≥420mm3/kg) was 85%(95%CI=70-94) and 95%(95%CI=90-98), respectively. In receiver-operating-curve curve analysis, 3D cAGV was superior to 2D cAGV for prediction of PTB (z=1.99, p=0.047). Conclusion 2D volume estimation of fetal adrenal gland using ellipsoid formula cannot replace 3D AGV calculations for prediction of PTB. PMID:22644825

  13. Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump

    PubMed Central

    Attia, A; Chaouachi, A; Padulo, J; Wong, DP; Chamari, K

    2016-01-01

    Common methods to estimate vertical jump height (VJH) are based on the measurements of flight time (FT) or vertical reaction force. This study aimed to assess the measurement errors when estimating the VJH with flight time using photocell devices in comparison with the gold standard jump height measured by a force plate (FP). The second purpose was to determine the intrinsic reliability of the Optojump photoelectric cells in estimating VJH. For this aim, 20 subjects (age: 22.50±1.24 years) performed maximal vertical jumps in three modalities in randomized order: the squat jump (SJ), counter-movement jump (CMJ), and CMJ with arm swing (CMJarm). Each trial was simultaneously recorded by the FP and Optojump devices. High intra-class correlation coefficients (ICCs) for validity (0.98-0.99) and low limits of agreement (less than 1.4 cm) were found; even a systematic difference in jump height was consistently observed between FT and double integration of force methods (-31% to -27%; p<0.001) and a large effect size (Cohen’s d>1.2). Intra-session reliability of Optojump was excellent, with ICCs ranging from 0.98 to 0.99, low coefficients of variation (3.98%), and low standard errors of measurement (0.8 cm). It was concluded that there was a high correlation between the two methods to estimate the vertical jump height, but the FT method cannot replace the gold standard, due to the large systematic bias. According to our results, the equations of each of the three jump modalities were presented in order to obtain a better estimation of the jump height. PMID:28416900

  14. A heuristic multi-criteria classification approach incorporating data quality information for choropleth mapping

    PubMed Central

    Sun, Min; Wong, David; Kronenfeld, Barry

    2016-01-01

    Despite conceptual and technology advancements in cartography over the decades, choropleth map design and classification fail to address a fundamental issue: estimates that are statistically indifferent may be assigned to different classes on maps or vice versa. Recently, the class separability concept was introduced as a map classification criterion to evaluate the likelihood that estimates in two classes are statistical different. Unfortunately, choropleth maps created according to the separability criterion usually have highly unbalanced classes. To produce reasonably separable but more balanced classes, we propose a heuristic classification approach to consider not just the class separability criterion but also other classification criteria such as evenness and intra-class variability. A geovisual-analytic package was developed to support the heuristic mapping process to evaluate the trade-off between relevant criteria and to select the most preferable classification. Class break values can be adjusted to improve the performance of a classification. PMID:28286426

  15. Adding Natural Areas to Social Indicators of Intra-Urban Health Inequalities among Children: A Case Study from Berlin, Germany.

    PubMed

    Kabisch, Nadja; Haase, Dagmar; Annerstedt van den Bosch, Matilda

    2016-08-04

    Research suggests that there is a relationship between the health of urban populations and the availability of green and water spaces in their daily environment. In this paper, we analyze the potential intra-urban relationships between children's health determinants and outcomes and natural areas in Berlin, Germany. In particular, health indicators such as deficits in viso-motoric development in children are related to environmental indicators such as the natural area cover, natural area per capita and distance to natural areas; however, these indicators are also correlated with social determinants of health. The methodological approach used in this study included bivariate and multivariate analyses to explore the relations between health inequalities and social, socio-economic, and land use parameters. The results on a sub-district level indicated that there was a correlation between natural areas and social health determinants, both of which displayed a certain intra-urban spatial pattern. In particular, a lower percentage of natural area cover was correlated with deficits in viso-motoric development. However, results with percentage of natural area cover and per capita natural area with childhood overweight were not conclusive. No significant correlation was found for percentage of natural area cover and overweight, while significant negative correlation values were found between overweight and per capita natural area. This was identified particularly in the districts that had lower social conditions. On the other hand, the districts with the highest social conditions had the comparatively lowest levels of complete measles immunization. This study may facilitate public health work by identifying the urban areas in which the strengthening of health resources and actions should be prioritized and also calls for the inclusion of natural areas among the social health indicators included in intra-urban health inequality tools.

  16. Adding Natural Areas to Social Indicators of Intra-Urban Health Inequalities among Children: A Case Study from Berlin, Germany

    PubMed Central

    Kabisch, Nadja; Haase, Dagmar; Annerstedt van den Bosch, Matilda

    2016-01-01

    Research suggests that there is a relationship between the health of urban populations and the availability of green and water spaces in their daily environment. In this paper, we analyze the potential intra-urban relationships between children’s health determinants and outcomes and natural areas in Berlin, Germany. In particular, health indicators such as deficits in viso-motoric development in children are related to environmental indicators such as the natural area cover, natural area per capita and distance to natural areas; however, these indicators are also correlated with social determinants of health. The methodological approach used in this study included bivariate and multivariate analyses to explore the relations between health inequalities and social, socio-economic, and land use parameters. The results on a sub-district level indicated that there was a correlation between natural areas and social health determinants, both of which displayed a certain intra-urban spatial pattern. In particular, a lower percentage of natural area cover was correlated with deficits in viso-motoric development. However, results with percentage of natural area cover and per capita natural area with childhood overweight were not conclusive. No significant correlation was found for percentage of natural area cover and overweight, while significant negative correlation values were found between overweight and per capita natural area. This was identified particularly in the districts that had lower social conditions. On the other hand, the districts with the highest social conditions had the comparatively lowest levels of complete measles immunization. This study may facilitate public health work by identifying the urban areas in which the strengthening of health resources and actions should be prioritized and also calls for the inclusion of natural areas among the social health indicators included in intra-urban health inequality tools. PMID:27527197

  17. Hypothesis: discrepancy between intra- and interpopulation studies of the relationship between dietary salt and blood pressure: fact or fiction?

    PubMed

    Omvik, P

    1984-01-01

    It is a paradox that intra-population studies fail to show significant correlation between sodium excretion and blood pressure while a clear relationship exists in cross-cultural studies. Since daily variation of sodium excretion is high, the discrepancy between the two observations could be due to non-comparable data on sodium excretion. This is a discussion of the hypothesis that the finding of a significant correlation or not between sodium excretion and blood pressure depends on the statistical analysis of the data.

  18. Visual and computer software-aided estimates of Dupuytren's contractures: correlation with clinical goniometric measurements.

    PubMed

    Smith, R P; Dias, J J; Ullah, A; Bhowal, B

    2009-05-01

    Corrective surgery for Dupuytren's disease represents a significant proportion of a hand surgeon's workload. The decision to go ahead with surgery and the success of surgery requires measuring the degree of contracture of the diseased finger(s). This is performed in clinic with a goniometer, pre- and postoperatively. Monitoring the recurrence of the contracture can inform on surgical outcome, research and audit. We compared visual and computer software-aided estimation of Dupuytren's contractures to clinical goniometric measurements in 60 patients with Dupuytren's disease. Patients' hands were digitally photographed. There were 76 contracted finger joints--70 proximal interphalangeal joints and six distal interphalangeal joints. The degrees of contracture of these images were visually assessed by six orthopaedic staff of differing seniority and re-assessed with computer software. Across assessors, the Pearson correlation between the goniometric measurements and the visual estimations was 0.83 and this significantly improved to 0.88 with computer software. Reliability with intra-class correlations achieved 0.78 and 0.92 for the visual and computer-aided estimations, respectively, and with test-retest analysis, 0.92 for visual estimation and 0.95 for computer-aided measurements. Visual estimations of Dupuytren's contractures correlate well with actual clinical goniometric measurements and improve further if measured with computer software. Digital images permit monitoring of contracture after surgery and may facilitate research into disease progression and auditing of surgical technique.

  19. Validation of a prediction model that allows direct comparison of the Oxford Knee Score and American Knee Society clinical rating system.

    PubMed

    Maempel, J F; Clement, N D; Brenkel, I J; Walmsley, P J

    2015-04-01

    This study demonstrates a significant correlation between the American Knee Society (AKS) Clinical Rating System and the Oxford Knee Score (OKS) and provides a validated prediction tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed five years after TKR and completed AKS assessments and an OKS questionnaire. Multivariate regression analysis demonstrated significant correlations between OKS and the AKS knee and function scores but a stronger correlation (r = 0.68, p < 0.001) when using the sum of the AKS knee and function scores. Addition of body mass index and age (other statistically significant predictors of OKS) to the algorithm did not significantly increase the predictive value. The simple regression model was used to predict the OKS in a group of 236 patients who were clinically assessed nine to ten years after TKR using the AKS system. The predicted OKS was compared with actual OKS in the second group. Intra-class correlation demonstrated excellent reliability (r = 0.81, 95% confidence intervals 0.75 to 0.85) for the combined knee and function score when used to predict OKS. Our findings will facilitate comparison of outcome data from studies and registries using either the OKS or the AKS scores and may also be of value for those undertaking meta-analyses and systematic reviews. ©2015 The British Editorial Society of Bone & Joint Surgery.

  20. Validation of use of subsets of teeth when applying the total mouth periodontal score (TMPS) system in dogs.

    PubMed

    Harvey, Colin E; Laster, Larry; Shofer, Frances S

    2012-01-01

    A total mouth periodontal score (TMPS) system in dogs has been described previously. Use of buccal and palatal/lingual surfaces of all teeth requires observation and recording of 120 gingivitis scores and 120 periodontitis scores. Although the result is a reliable, repeatable assessment of the extent of periodontal disease in the mouth, observing and recording 240 data points is time-consuming. Using data from a previously reported study of periodontal disease in dogs, correlation analysis was used to determine whether use of any of seven different subsets of teeth can generate TMPS subset gingivitis and periodontitis scores that are highly correlated with TMPS all-site, all-teeth scores. Overall, gingivitis scores were less highly correlated than periodontitis scores. The minimal tooth set with a significant intra-class correlation (> or = 0.9 of means of right and left sides) for both gingivitis scores and attachment loss measurements consisted of the buccal surface of the maxillary third incisor canine, third premolar fourth premolar; and first molar teeth; and, the mandibular canine, third premolar, fourth premolar and first molar teeth on one side (9 teeth, 15 root sites). Use of this subset of teeth, which reduces the number of data points per dog from 240 to 30 for gingivitis and periodontitis at each scoring episode, is recommended when calculating the gingivitis and periodontitis scores using the TMPS system.

  1. Detecting Unknown Artificial Urban Surface Materials Based on Spectral Dissimilarity Analysis.

    PubMed

    Jilge, Marianne; Heiden, Uta; Habermeyer, Martin; Mende, André; Juergens, Carsten

    2017-08-08

    High resolution imaging spectroscopy data have been recognised as a valuable data resource for augmenting detailed material inventories that serve as input for various urban applications. Image-specific urban spectral libraries are successfully used in urban imaging spectroscopy studies. However, the regional- and sensor-specific transferability of such libraries is limited due to the wide range of different surface materials. With the developed methodology, incomplete urban spectral libraries can be utilised by assuming that unknown surface material spectra are dissimilar to the known spectra in a basic spectral library (BSL). The similarity measure SID-SCA (Spectral Information Divergence-Spectral Correlation Angle) is applied to detect image-specific unknown urban surfaces while avoiding spectral mixtures. These detected unknown materials are categorised into distinct and identifiable material classes based on their spectral and spatial metrics. Experimental results demonstrate a successful redetection of material classes that had been previously erased in order to simulate an incomplete BSL. Additionally, completely new materials e.g., solar panels were identified in the data. It is further shown that the level of incompleteness of the BSL and the defined dissimilarity threshold are decisive for the detection of unknown material classes and the degree of spectral intra-class variability. A detailed accuracy assessment of the pre-classification results, aiming to separate natural and artificial materials, demonstrates spectral confusions between spectrally similar materials utilizing SID-SCA. However, most spectral confusions occur between natural or artificial materials which are not affecting the overall aim. The dissimilarity analysis overcomes the limitations of working with incomplete urban spectral libraries and enables the generation of image-specific training databases.

  2. Detecting Unknown Artificial Urban Surface Materials Based on Spectral Dissimilarity Analysis

    PubMed Central

    Jilge, Marianne; Heiden, Uta; Habermeyer, Martin; Mende, André; Juergens, Carsten

    2017-01-01

    High resolution imaging spectroscopy data have been recognised as a valuable data resource for augmenting detailed material inventories that serve as input for various urban applications. Image-specific urban spectral libraries are successfully used in urban imaging spectroscopy studies. However, the regional- and sensor-specific transferability of such libraries is limited due to the wide range of different surface materials. With the developed methodology, incomplete urban spectral libraries can be utilised by assuming that unknown surface material spectra are dissimilar to the known spectra in a basic spectral library (BSL). The similarity measure SID-SCA (Spectral Information Divergence-Spectral Correlation Angle) is applied to detect image-specific unknown urban surfaces while avoiding spectral mixtures. These detected unknown materials are categorised into distinct and identifiable material classes based on their spectral and spatial metrics. Experimental results demonstrate a successful redetection of material classes that had been previously erased in order to simulate an incomplete BSL. Additionally, completely new materials e.g., solar panels were identified in the data. It is further shown that the level of incompleteness of the BSL and the defined dissimilarity threshold are decisive for the detection of unknown material classes and the degree of spectral intra-class variability. A detailed accuracy assessment of the pre-classification results, aiming to separate natural and artificial materials, demonstrates spectral confusions between spectrally similar materials utilizing SID-SCA. However, most spectral confusions occur between natural or artificial materials which are not affecting the overall aim. The dissimilarity analysis overcomes the limitations of working with incomplete urban spectral libraries and enables the generation of image-specific training databases. PMID:28786947

  3. Random spot urine protein to creatinine ratio is a reliable measure of proteinuria in lupus nephritis in Koreans.

    PubMed

    Choi, In Ah; Park, Jin Kyun; Lee, Eun Young; Song, Yeong Wook; Lee, Eun Bong

    2013-01-01

    The accurate assessment of proteinuria is critical for the management of lupus nephritis. Measuring the protein to creatinine (P/C) ratio in random spot urine (RSU) samples has been introduced as an alternative to the 24-hour (24h) urine collection method. However, it remains unclear as to whether the RSU P/C ratio is reliable for assessing lupus nephritis (LN) in routine clinical practice. In total, 275 pairs of 24h urine and RSU samples from 102 patients with biopsy-proven LN were analysed. The correlation and concordance between the P/C ratios in the two sample types were assessed by Pearson or Spearman correlation and intra-class correlation coefficient (ICC) using mixed models for repeated measurements, respectively. The mean 24h urine P/C ratio was 3.2 ± 4.9. Overall, RSU P/C ratio correlated strongly with the 24h urine P/C ratio (r=0.944, p<0.001) with an excellent agreement (ICC=0.949, 95% confidence interval [CI]: 0.69-1.00). Subgroup analyses revealed that the correlation remained high in class II, III, IV, and V LN (rho=0.868, p<0.001; rho=0.649, p=0.007; r=0.945, p<0.001; and rho=0.900, p=0.001, respectively). The correlation between the 24h urine and RSU P/C ratio in the range of 0.5 to 3 was good (r=0.720, p<0.001) with ICC of 0.659 (95%CI 0.554-0.812). RSU P/C ratio ≥0.5 could predict 24h PCR ≥0.5 with 91.7% sensitivity and 70.2% specificity, whereas RSU P/C ratio ≥1.0 increased specificity up to 94.7%. The RSU P/C ratio is an excellent alternative to the 24 hour P/C ratio for assessing the presence of clinically significant proteinuria in LN. RSU P/C ratio >1.0 may prompt directly to a renal biopsy, whereas RSU P/C ratio between 0.5-1.0 should be followed by a confirmatory 24h urine collection.

  4. An object-oriented software approach for a distributed human tracking motion system

    NASA Astrophysics Data System (ADS)

    Micucci, Daniela L.

    2003-06-01

    Tracking is a composite job involving the co-operation of autonomous activities which exploit a complex information model and rely on a distributed architecture. Both information and activities must be classified and related in several dimensions: abstraction levels (what is modelled and how information is processed); topology (where the modelled entities are); time (when entities exist); strategy (why something happens); responsibilities (who is in charge of processing the information). A proper Object-Oriented analysis and design approach leads to a modular architecture where information about conceptual entities is modelled at each abstraction level via classes and intra-level associations, whereas inter-level associations between classes model the abstraction process. Both information and computation are partitioned according to level-specific topological models. They are also placed in a temporal framework modelled by suitable abstractions. Domain-specific strategies control the execution of the computations. Computational components perform both intra-level processing and intra-level information conversion. The paper overviews the phases of the analysis and design process, presents major concepts at each abstraction level, and shows how the resulting design turns into a modular, flexible and adaptive architecture. Finally, the paper sketches how the conceptual architecture can be deployed into a concrete distribute architecture by relying on an experimental framework.

  5. Face biometrics with renewable templates

    NASA Astrophysics Data System (ADS)

    van der Veen, Michiel; Kevenaar, Tom; Schrijen, Geert-Jan; Akkermans, Ton H.; Zuo, Fei

    2006-02-01

    In recent literature, privacy protection technologies for biometric templates were proposed. Among these is the so-called helper-data system (HDS) based on reliable component selection. In this paper we integrate this approach with face biometrics such that we achieve a system in which the templates are privacy protected, and multiple templates can be derived from the same facial image for the purpose of template renewability. Extracting binary feature vectors forms an essential step in this process. Using the FERET and Caltech databases, we show that this quantization step does not significantly degrade the classification performance compared to, for example, traditional correlation-based classifiers. The binary feature vectors are integrated in the HDS leading to a privacy protected facial recognition algorithm with acceptable FAR and FRR, provided that the intra-class variation is sufficiently small. This suggests that a controlled enrollment procedure with a sufficient number of enrollment measurements is required.

  6. Medical image diagnoses by artificial neural networks with image correlation, wavelet transform, simulated annealing

    NASA Astrophysics Data System (ADS)

    Szu, Harold H.

    1993-09-01

    Classical artificial neural networks (ANN) and neurocomputing are reviewed for implementing a real time medical image diagnosis. An algorithm known as the self-reference matched filter that emulates the spatio-temporal integration ability of the human visual system might be utilized for multi-frame processing of medical imaging data. A Cauchy machine, implementing a fast simulated annealing schedule, can determine the degree of abnormality by the degree of orthogonality between the patient imagery and the class of features of healthy persons. An automatic inspection process based on multiple modality image sequences is simulated by incorporating the following new developments: (1) 1-D space-filling Peano curves to preserve the 2-D neighborhood pixels' relationship; (2) fast simulated Cauchy annealing for the global optimization of self-feature extraction; and (3) a mini-max energy function for the intra-inter cluster-segregation respectively useful for top-down ANN designs.

  7. Cross-cultural adaptation of the Innsbruck Health Dimensions Questionnaire for Neurosurgical Patients (IHD-NS).

    PubMed

    Santos, Camila Batista dos; Carvalho, Simone Carneiro Ahualli de; Silva, Maria Fernanda Gouveia da; Fuentes, Daniel; Santana, Pedro Augusto; Furlan, André Beer; Aguiar, Paulo Henrique Pires de

    2008-09-01

    The goal of this study was to accomplish the cross-cultural adaptation of a quality of life instrument, specific for neurosurgical patients, called Innsbruck Health Dimensions Questionnaire for Neurosurgical Patients (IHD-NS). Thirty patients participated in this study, male and female, all having been submitted to brain tumor surgery more than twelve months before, and whose ages ranged from 26 to 66. After the process of translation/back translation and the elaboration of the Brazilian version of the instrument, the patients were assessed and reassessed within a one-month period. Statistical analyses evinced the preservation of the internal consistency, high agreement levels and highly significant intra-class correlation, allowing for the belief in the quality and reliability of the Portuguese version, named Questionário de Dimensões de Saúde para Pacientes Neurocirúrgicos de Innsbruck--DSI (NC).

  8. Inter and intra-observer reliability in assessment of the position of the lateral sesamoid in determining the severity of hallux valgus.

    PubMed

    Panchani, Sunil; Reading, Jonathan; Mehta, Jaysheel

    2016-06-01

    The position of the lateral sesamoid on standard dorso-plantar weight bearing radiographs, with respect to the lateral cortex of the first metatarsal, has been shown to correlate well with the degree of the hallux valgus angle. This study aimed to assess the inter- and intra-observer error of this new classification system. Five orthopaedic consultants and five trainee orthopaedic surgeons were recruited to assess and document the degree of displacement of the lateral sesamoid on 144 weight-bearing dorso-plantar radiographs on two separate occasions. The severity of hallux valgus was defined as normal (0%), mild (≤50%), moderate (51-≤99%) or severe (≥100%) depending on the percentage displacement of the lateral sesamoid body from the lateral cortical border of the first metatarsal. Consultant intra-observer variability showed good agreement between repeated assessment of the radiographs (mean Kappa=0.75). Intra-observer variability for trainee orthopaedic surgeons also showed good agreement with a mean Kappa=0.73. Intraclass correlations for consultants and trainee surgeons was also high. The new classification system of assessing the severity of hallux valgus shows high inter- and intra-observer variability with good agreement and reproducibility between surgeons of consultant and trainee grades. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Hypocretin measurement: shelf age of radioimmunoassay kit, but not freezer time, influences assay variability.

    PubMed

    Keating, Glenda; Bliwise, Donald L; Saini, Prabhjyot; Rye, David B; Trotti, Lynn Marie

    2017-09-01

    The hypothalamic peptide hypocretin 1 (orexin A) may be assayed in cerebrospinal fluid to diagnose narcolepsy type 1. This testing is not commercially available, and factors contributing to assay variability have not previously been comprehensively explored. In the present study, cerebrospinal fluid hypocretin concentrations were determined in duplicate in 155 patient samples, across a range of sleep disorders. Intra-assay variability of these measures was analyzed. Inter-assay correlation between samples tested at Emory and at Stanford was high (r = 0.79, p < 0.0001). Intra-assay correlation between samples tested in duplicate in our center was also high (r = 0.88, p < 0.0001); intra-assay variability, expressed as the difference between values as a percentage of the higher value, was low at 9.4% (SD = 7.9%). Although both time the sample spent in the freezer (r = 0.16, p = 0.04) and age of the kit used for assay (t = 3.64, p = 0.0004) were significant predictors of intra-kit variability in univariate analyses, only age of kit was significant in multivariate linear regression (F = 4.93, p = 0.03). Age of radioimmunoassay kit affects intra-kit variability of measured hypocretin values, such that kits closer to expiration exhibit significantly more variability.

  10. Chinese translation and validation of the Walking Impairment Questionnaire in patients with peripheral artery disease.

    PubMed

    Yan, Bryan P; Lau, James Y; Yu, Check-Man; Au, Kim; Chan, Ka-Wai; Yu, Doris S; Ma, Ronald C; Lam, Yat-Yin; Hiatt, William R

    2011-06-01

    The Walking Impairment Questionnaire (WIQ) is a frequently used questionnaire to evaluate patients with intermittent claudication on four subscales: pain severity, walking distance, walking speed and the ability to climb stairs. The aim of this study is to translate and validate the WIQ in Chinese. After translation and cultural adaptation of the WIQ, 134 patients with intermittent claudication completed the Chinese WIQ and European Quality of Life 5 Dimension (EQ-5D). Walking distances were determined by the 6-minute walk test (6MWT). Correlations between the WIQ, quality of life questionnaire and walking distances were calculated to determine validity. Reliability and internal consistency were determined using the intra-class correlation coefficient (ICC) and Cronbach's alpha (α), respectively. Significant correlations were found between the WIQ score, initial claudication distance (ICD), absolute claudication distance (ACD) and all domains of the EQ-5D (all p ≤ 0.01). Test-retest reliability (ICC = 0.74) and the overall internal consistency determined (α = 0.90) showed good agreement. A lower WIQ score corresponded to shorter walking distances. In conclusion, this study showed that the Chinese version of the WIQ is a valid, reliable and clinically relevant instrument for assessing walking impairment in patients with intermittent claudication.

  11. Estimating the reliability of repeatedly measured endpoints based on linear mixed-effects models. A tutorial.

    PubMed

    Van der Elst, Wim; Molenberghs, Geert; Hilgers, Ralf-Dieter; Verbeke, Geert; Heussen, Nicole

    2016-11-01

    There are various settings in which researchers are interested in the assessment of the correlation between repeated measurements that are taken within the same subject (i.e., reliability). For example, the same rating scale may be used to assess the symptom severity of the same patients by multiple physicians, or the same outcome may be measured repeatedly over time in the same patients. Reliability can be estimated in various ways, for example, using the classical Pearson correlation or the intra-class correlation in clustered data. However, contemporary data often have a complex structure that goes well beyond the restrictive assumptions that are needed with the more conventional methods to estimate reliability. In the current paper, we propose a general and flexible modeling approach that allows for the derivation of reliability estimates, standard errors, and confidence intervals - appropriately taking hierarchies and covariates in the data into account. Our methodology is developed for continuous outcomes together with covariates of an arbitrary type. The methodology is illustrated in a case study, and a Web Appendix is provided which details the computations using the R package CorrMixed and the SAS software. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Reliability of concentrations of organophosphate pesticide metabolites in serial urine specimens from pregnancy in the Generation R Study.

    PubMed

    Spaan, Suzanne; Pronk, Anjoeka; Koch, Holger M; Jusko, Todd A; Jaddoe, Vincent W V; Shaw, Pamela A; Tiemeier, Henning M; Hofman, Albert; Pierik, Frank H; Longnecker, Matthew P

    2015-05-01

    The widespread use of organophosphate (OP) pesticides has resulted in ubiquitous exposure in humans, primarily through their diet. Exposure to OP pesticides may have adverse health effects, including neurobehavioral deficits in children. The optimal design of new studies requires data on the reliability of urinary measures of exposure. In the present study, urinary concentrations of six dialkyl phosphate (DAP) metabolites, the main urinary metabolites of OP pesticides, were determined in 120 pregnant women participating in the Generation R Study in Rotterdam. Intra-class correlation coefficients (ICCs) across serial urine specimens taken at <18, 18-25, and >25 weeks of pregnancy were determined to assess reliability. Geometric mean total DAP metabolite concentrations were 229 (GSD 2.2), 240 (GSD 2.1), and 224 (GSD 2.2) nmol/g creatinine across the three periods of gestation. Metabolite concentrations from the serial urine specimens in general correlated moderately. The ICCs for the six DAP metabolites ranged from 0.14 to 0.38 (0.30 for total DAPs), indicating weak to moderate reliability. Although the DAP metabolite levels observed in this study are slightly higher and slightly more correlated than in previous studies, the low to moderate reliability indicates a high degree of within-person variability, which presents challenges for designing well-powered epidemiological studies.

  13. Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear

    PubMed Central

    Choi, Jin-Il; Jost-Brinkmann, Paul-Georg; Choi, Dong-Soon; Jang, In-San

    2012-01-01

    Objective The purpose of this study was to evaluate the validity of the 3-dimensional (3D) superimposition method of digital models in patients who received treatment with rapid maxillary expansion (RME) and maxillary protraction headgear. Methods The material consisted of pre- and post-treatment maxillary dental casts and lateral cephalograms of 30 patients, who underwent RME and maxillary protraction headgear treatment. Digital models were superimposed using the palate as a reference area. The movement of the maxillary central incisor and the first molar was measured on superimposed cephalograms and 3D digital models. To determine whether any difference existed between the 2 measuring techniques, intra-class correlation (ICC) and Bland-Altman plots were analyzed. Results The measurements on the 3D digital models and cephalograms showed a very high correlation in the antero-posterior direction (ICC, 0.956 for central incisor and 0.941 for first molar) and a moderate correlation in the vertical direction (ICC, 0.748 for central incisor and 0.717 for first molar). Conclusions The 3D model superimposition method using the palate as a reference area is as clinically reliable for assessing antero-posterior tooth movement as cephalometric superimposition, even in cases treated with orthopedic appliances, such as RME and maxillary protraction headgear. PMID:23173116

  14. Psychometric testing of the modified Care Dependency Scale (Neuro-CDS).

    PubMed

    Piredda, Michela; Biagioli, Valentina; Gambale, Giulia; Porcelli, Elisa; Barbaranelli, Claudio; Palese, Alvisa; De Marinis, Maria Grazia

    2016-01-01

    Effective measures of nursing care dependency in neurorehabilitation are warranted to plan nursing interventions to help patients avoid increasing dependency. The Care Dependency Scale (CDS) is a theory-based, comprehensive tool to evaluate functional disability. This study aimed to modify the CDS for neurological and neurorehabilitation patients (Neuro-CDS) and to test its psychometric properties in adult neurorehabilitation inpatients. Exploratory factor analysis (EFA) was performed using a Maximum Likelihood robust (MLR) estimator. The Barthel Index (BI) was used to evaluate concurrent validity. Stability was measured using the Intra-class Correlation Coefficient (ICC). The sample included 124 patients (mean age = 69.7 years, 54% male). The EFA revealed a two-factor structure with good fit indexes, Factor 1 (Physical care dependence) loaded by 11 items and Factor 2 (Psycho-social care dependence) loaded by 4 items. The correlation between factors was 0.61. Correlations between Factor 1 and the BI and between Factor 2 and the BI were r = 0.843 and r = 0.677, respectively (p <  0.001). The Cronbach's alpha coefficients were 0.99 and 0.88 (Factor 1 and 2). The ICC was 0.98. The Neuro-CDS is multidimensional, valid, reliable, straightforward, and able to measure care dependence in neurorehabilitation patients as a basis for individualized and holistic care.

  15. The City of Hope-Quality of Life-Ostomy Questionnaire: Persian Translation and Validation

    PubMed Central

    Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M

    2014-01-01

    Background: Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. Aim: This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). Subjects and Methods: This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Results: Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. Conclusion: The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future. PMID:25221719

  16. Probing inter- and intrachain Zhang-Rice excitons in Li 2 CuO 2 and determining their binding energy

    DOE PAGES

    Monney, Claude; Bisogni, Valentina; Zhou, Ke-Jin; ...

    2016-10-10

    Cuprate materials, such as those hosting high-temperature superconductivity, represent a famous class of materials where the correlations between the strongly entangled charges and spins produce complex phase diagrams. Several years ago, the Zhang-Rice singlet was proposed as a natural quasiparticle in hole-doped cuprates. The occurrence and binding energy of this quasiparticle, consisting of a pair of bound holes with antiparallel spins on the same CuO 4 plaquette, depends on the local electronic interactions, which are fundamental quantities for understanding the physics of the cuprates. Here, we employ state-of-the-art resonant inelastic x-ray scattering (RIXS) to probe the correlated physics of themore » CuO 4 plaquettes in the quasi-one-dimensional chain cuprate Li 2CuO 2. By tuning the incoming photon energy to the O K edge, we populate bound states related to the Zhang-Rice quasiparticles in the RIXS process. Both intra- and interchain Zhang-Rice singlets are observed and their occurrence is shown to depend on the nearest-neighbor spin-spin correlations, which are readily probed in this experiment. Finally, we also extract the binding energy of the Zhang-Rice singlet and identify the Zhang-Rice triplet excitation in the RIXS spectra.« less

  17. Predicting chroma from luma with frequency domain intra prediction

    NASA Astrophysics Data System (ADS)

    Egge, Nathan E.; Valin, Jean-Marc

    2015-03-01

    This paper describes a technique for performing intra prediction of the chroma planes based on the reconstructed luma plane in the frequency domain. This prediction exploits the fact that while RGB to YUV color conversion has the property that it decorrelates the color planes globally across an image, there is still some correlation locally at the block level.1 Previous proposals compute a linear model of the spatial relationship between the luma plane (Y) and the two chroma planes (U and V).2 In codecs that use lapped transforms this is not possible since transform support extends across the block boundaries3 and thus neighboring blocks are unavailable during intra- prediction. We design a frequency domain intra predictor for chroma that exploits the same local correlation with lower complexity than the spatial predictor and which works with lapped transforms. We then describe a low- complexity algorithm that directly uses luma coefficients as a chroma predictor based on gain-shape quantization and band partitioning. An experiment is performed that compares these two techniques inside the experimental Daala video codec and shows the lower complexity algorithm to be a better chroma predictor.

  18. Different hip and knee priority score systems: are they good for the same thing?

    PubMed

    Escobar, Antonio; Quintana, Jose Maria; Espallargues, Mireia; Allepuz, Alejandro; Ibañez, Berta

    2010-10-01

    The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar. © 2010 Blackwell Publishing Ltd.

  19. Utility of Angle Correction for Hemodynamic Measurements with Doppler Echocardiography.

    PubMed

    Sigurdsson, Martin I; Eoh, Eun J; Chow, Vinca W; Waldron, Nathan H; Cleve, Jayne; Nicoara, Alina; Swaminathan, Madhav

    2018-04-06

    The routine application angle correction (AnC) in hemodynamic measurements with transesophageal echocardiography currently is not recommended but potentially could be beneficial. The authors hypothesized that AnC can be applied reliably and may change grading of aortic stenosis (AS). Retrospective analysis. Single institution, university hospital. During phase I, use of AnC was assessed in 60 consecutive patients with intraoperative transesophageal echocardiography. During phase II, 129 images from a retrospective cohort of 117 cases were used to quantify AS by mean pressure gradient. A panel of observers used custom-written software in Java to measure intra-individual and inter-individual correlation in AnC application, correlation with preoperative transthoracic echocardiography gradients, and regrading of AS after AnC. For phase I, the median AnC was 21 (16-35) degrees, and 17% of patients required no AnC. For phase II, the median AnC was 7 (0-15) degrees, and 37% of assessed images required no AnC. The mean inter-individual and intra-individual correlation for AnC was 0.50 (95% confidence interval [CI] 0.49-0.52) and 0.87 (95% CI 0.82-0.92), respectively. AnC did not improve agreement with the transthoracic echocardiography mean pressure gradient. The mean inter-rater and intra-rater agreement for grading AS severity was 0.82 (95% CI 0.81-0.83) and 0.95 (95% CI 0.91-0.95), respectively. A total of 241 (7%) AS gradings were reclassified after AnC was applied, mostly when the uncorrected mean gradient was within 5 mmHg of the severity classification cutoff. AnC can be performed with a modest inter-rater and intra-rater correlation and high degree of inter-rater and intra-rater agreement for AS severity grading. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. A Comparison of Mandibular Transverse Dimensions of a Class I Normal and Class II Patient Population using Anterior to Posterior Measurement Ratios

    DTIC Science & Technology

    2012-04-13

    orthodontic and surgical options for intra-arch corrections. Instability of the mandible when expanded with removable appliances has been described by... orthodontic fields within the last ten years. This technique requires a surgical split at the symphysis followed by slow expansion, which allows hard...often viewed with much skepticism from the orthodontic and surgical communities. Indeed, there are definite limitations to corrections in this

  1. Analysis of the psychometric properties of the American Orthopaedic Foot and Ankle Society Score (AOFAS) in rheumatoid arthritis patients: application of the Rasch model.

    PubMed

    Conceição, Cristiano Sena da; Neto, Mansueto Gomes; Neto, Anolino Costa; Mendes, Selena M D; Baptista, Abrahão Fontes; Sá, Kátia Nunes

    2016-01-01

    To tested the reliability and validity of Aofas in a sample of rheumatoid arthritis patients. The scale was applicable to rheumatoid arthritis patients, twice by the interviewer 1 and once by the interviewer 2. The Aofas was subjected to test-retest reliability analysis (with 20 Rheumatoid arthritis subjects). The psychometric properties were investigated using Rasch analysis on 33 Rheumatoid arthritis patients. Intra-Class Correlation Coefficient (ICC) were (0.90

  2. Measuring acetabular component position on lateral radiographs - ischio-lateral method.

    PubMed

    Pulos, Nicholas; Tiberi Iii, John V; Schmalzried, Thomas P

    2011-01-01

    The standard method for the evaluation of arthritis and postoperative assessment of arthroplasty treatment is observation and measurement from plain films, using the flm edge for orientation. A more recent employment of an anatomical landmark, the ischial tuberosity, has come into use as orientation for evaluation and is called the ischio-lateral method. In this study, the use of this method was evaluated as a first report to the literature on acetabular component measurement using a skeletal reference with lateral radiographs. Postoperative radiographs of 52 hips, with at least three true lateral radiographs taken at different time periods, were analyzed. Component position was measured with the historical method (using the flm edge for orientation) and with the new method using the ischio-lateral method. The mean standard deviation (SD) for the historical approach was 3.7° and for the ischio-lateral method, 2.2° (p < 0.001). With the historical method, 19 (36.5%) hips had a SD greater than ± 4°, compared to six hips (11.5%) with the ischio-lateral method. By using a skeletal reference, the ischio-lateral method provides a more consistent measurement of acetabular component position. The high intra-class correlation coefficients for both intra- and inter-observer reliability indicate that the angle measured with this simple method, which employs no further technology, increased time, or cost, is consistent and reproducible for multiple observers.

  3. Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

    PubMed

    Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M

    2015-12-01

    Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.

  4. Body Fat Patterning, Hepatic Fat and Pancreatic Volume of Non-Obese Asian Indians with Type 2 Diabetes in North India: A Case-Control Study

    PubMed Central

    Misra, Anoop; Anoop, Shajith; Gulati, Seema; Mani, Kalaivani; Bhatt, Surya Prakash; Pandey, Ravindra Mohan

    2015-01-01

    Objective To evaluate body fat patterning and phenotype including hepatic fat and pancreatic volume of non-obese (BMI: < 25 kg/m2) Asian Indians with type 2 diabetes residing in North India. Methods Non-obese patients with type 2 diabetes (n = 93) and non-obese, normo-glycemic subjects (n = 40) were recruited. BMI, waist & hip circumferences, skinfold thickness at 8 sites, body fat, lean mass and detailed abdominal fat evaluation [total abdominal fat, total subcutaneous fat (superficial, deep, anterior, and posterior), total intra-abdominal fat (intra-peritoneal, retroperitoneal)], liver span, grades of fatty liver and pancreatic volume were compared. Results Waist circumference, subscapular skinfolds and total truncal fat (on DEXA) were higher whereas calf, total peripheral skinfolds and total leg fat (on DEXA) lower in patients. Specifically, the following volumes were higher in cases as compared to controls; total abdominal fat (19.4%), total intra-abdominal fat (49.7%), intra-peritoneal fat (47.7%), retroperitoneal fat (70.7%), pancreatic volume (26.6%), pancreatic volume index (21.3%) and liver span (10.8%). In cases, significant positive correlations were observed for pancreatic volume with BMI, waist and hip circumferences, W-HR, subscapular, abdominal and total truncal skinfolds, truncal, total subcutaneous, total intra-abdominal, intra-peritoneal, retroperitoneal fat depots, liver span and fatty liver. Conclusions In non-obese Asian Indians with type 2 diabetes, subcutaneous and intra-abdominal obesity, including fatty liver, and pancreatic volume were higher and peripheral subcutaneous adiposity was lower than BMI matched non-diabetic subjects. Importantly, increased pancreatic volume in patients was highly correlated with multiple measures of abdominal obesity and liver fat. PMID:26474415

  5. Correlation between intra-abdominal pressure and pulmonary volumes after superior and inferior abdominal surgery.

    PubMed

    Cleva, Roberto de; Assumpção, Marianna Siqueira de; Sasaya, Flavia; Chaves, Natalia Zuniaga; Santo, Marco Aurelio; Fló, Claudia; Lunardi, Adriana C; Jacob Filho, Wilson

    2014-07-01

    Patients undergoing abdominal surgery are at risk for pulmonary complications. The principal cause of postoperative pulmonary complications is a significant reduction in pulmonary volumes (FEV1 and FVC) to approximately 65-70% of the predicted value. Another frequent occurrence after abdominal surgery is increased intra-abdominal pressure. The aim of this study was to correlate changes in pulmonary volumes with the values of intra-abdominal pressure after abdominal surgery, according to the surgical incision in the abdomen (superior or inferior). We prospectively evaluated 60 patients who underwent elective open abdominal surgery with a surgical time greater than 240 minutes. Patients were evaluated before surgery and on the 3rd postoperative day. Spirometry was assessed by maximal respiratory maneuvers and flow-volume curves. Intra-abdominal pressure was measured in the postoperative period using the bladder technique. The mean age of the patients was 56 ± 13 years, and 41.6% 25 were female; 50 patients (83.3%) had malignant disease. The patients were divided into two groups according to the surgical incision (superior or inferior). The lung volumes in the preoperative period showed no abnormalities. After surgery, there was a significant reduction in both FEV1 (1.6 ± 0.6 L) and FVC (2.0 ± 0.7 L) with maintenance of FEV1/FVC of 0.8 ± 0.2 in both groups. The maximum intra-abdominal pressure values were similar (p=0.59) for the two groups. There was no association between pulmonary volumes and intra-abdominal pressure measured in any of the groups analyzed. Our results show that superior and inferior abdominal surgery determines hypoventilation, unrelated to increased intra-abdominal pressure. Patients at high risk of pulmonary complications should receive respiratory care even if undergoing inferior abdominal surgery.

  6. High intralocus variability and interlocus recombination promote immunological diversity in a minimal major histocompatibility system.

    PubMed

    Wilson, Anthony B; Whittington, Camilla M; Bahr, Angela

    2014-12-20

    The genes of the major histocompatibility complex (MHC/MH) have attracted considerable scientific interest due to their exceptional levels of variability and important function as part of the adaptive immune system. Despite a large number of studies on MH class II diversity of both model and non-model organisms, most research has focused on patterns of genetic variability at individual loci, failing to capture the functional diversity of the biologically active dimeric molecule. Here, we take a systematic approach to the study of MH variation, analyzing patterns of genetic variation at MH class IIα and IIβ loci of the seahorse, which together form the immunologically active peptide binding cleft of the MH class II molecule. The seahorse carries a minimal class II system, consisting of single copies of both MH class IIα and IIβ, which are physically linked and inherited in a Mendelian fashion. Both genes are ubiquitously expressed and detectible in the brood pouch of male seahorses throughout pregnancy. Genetic variability of the two genes is high, dominated by non-synonymous variation concentrated in their peptide-binding regions. Coding variation outside these regions is negligible, a pattern thought to be driven by intra- and interlocus recombination. Despite the tight physical linkage of MH IIα and IIβ loci, recombination has produced novel composite alleles, increasing functional diversity at sites responsible for antigen recognition. Antigen recognition by the adaptive immune system of the seahorse is enhanced by high variability at both MH class IIα and IIβ loci. Strong positive selection on sites involved in pathogen recognition, coupled with high levels of intra- and interlocus recombination, produce a patchwork pattern of genetic variation driven by genetic hitchhiking. Studies focusing on variation at individual MH loci may unintentionally overlook an important component of ecologically relevant variation.

  7. Heritabilities and genetic correlations in the same traits across different strata of herds created according to continuous genomic, genetic, and phenotypic descriptors.

    PubMed

    Yin, Tong; König, Sven

    2018-03-01

    The most common approach in dairy cattle to prove genotype by environment interactions is a multiple-trait model application, and considering the same traits in different environments as different traits. We enhanced such concepts by defining continuous phenotypic, genetic, and genomic herd descriptors, and applying random regression sire models. Traits of interest were test-day traits for milk yield, fat percentage, protein percentage, and somatic cell score, considering 267,393 records from 32,707 first-lactation Holstein cows. Cows were born in the years 2010 to 2013, and kept in 52 large-scale herds from 2 federal states of north-east Germany. The average number of genotyped cows per herd (45,613 single nucleotide polymorphism markers per cow) was 133.5 (range: 45 to 415 genotyped cows). Genomic herd descriptors were (1) the level of linkage disequilibrium (r 2 ) within specific chromosome segments, and (2) the average allele frequency for single nucleotide polymorphisms in close distance to a functional mutation. Genetic herd descriptors were the (1) intra-herd inbreeding coefficient, and (2) the percentage of daughters from foreign sires. Phenotypic herd descriptors were (1) herd size, and (2) the herd mean for nonreturn rate. Most correlations among herd descriptors were close to 0, indicating independence of genomic, genetic, and phenotypic characteristics. Heritabilities for milk yield increased with increasing intra-herd linkage disequilibrium, inbreeding, and herd size. Genetic correlations in same traits between adjacent levels of herd descriptors were close to 1, but declined for descriptor levels in greater distance. Genetic correlation declines were more obvious for somatic cell score, compared with test-day traits with larger heritabilities (fat percentage and protein percentage). Also, for milk yield, alterations of herd descriptor levels had an obvious effect on heritabilities and genetic correlations. By trend, multiple trait model results (based on created discrete herd classes) confirmed the random regression estimates. Identified alterations of breeding values in dependency of herd descriptors suggest utilization of specific sires for specific herd structures, offering new possibilities to improve sire selection strategies. Regarding genomic selection designs and genetic gain transfer into commercial herds, cow herds for the utilization in cow training sets should reflect the genomic, genetic, and phenotypic pattern of the broad population. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Sciatic neurosteatosis: Relationship with age, gender, obesity and height.

    PubMed

    Ratner, Shayna; Khwaja, Raamis; Zhang, Lihua; Xi, Yin; Dessouky, Riham; Rubin, Craig; Chhabra, Avneesh

    2018-04-01

    To evaluate inter-reader performance for cross-sectional area and fat quantification of bilateral sciatic nerves on MRI and assess correlations with anthropometrics. In this IRB-approved, HIPPA-compliant study, three readers performed a cross-sectional analysis of 3T lumbosacral plexus MRIs over an 18-month period. Image slices were evaluated at two levels (A and B). The sciatic nerve was outlined using a free hand region of interest tool on PACS. Proton-density fat fraction (FF) and cross-sectional areas were recorded. Inter-reader agreement was assessed using intra-class correlation coefficient (ICC). Spearman correlation coefficients were used for correlations with age, BMI and height and Wilcoxon rank sum test was used to assess gender differences. A total of 67 patients were included in this study with male to female ratio of 1:1. Inter-reader agreement was good to excellent for FF measurements at both levels (ICC=0.71-0.90) and poor for sciatic nerve areas (ICC=0.08-0.27). Positive correlations of sciatic FF and area were seen with age (p value<0.05). Males had significantly higher sciatic intraneural fat than females (p<0.05). Fat quantification MRI is highly reproducible with significant positive correlations of sciatic FF and area with age, which may have implications for MRI diagnosis of sciatic neuropathy. • MR proton density fat fraction is highly reproducible at multiple levels. • Sciatic intraneural fat is positively correlated with increasing age (p < 0.05). • Positive correlations exist between bilateral sciatic nerve areas and age (p < 0.05). • Males had significantly higher sciatic intraneural fat than females (p < 0.05).

  9. The Development and Validation of a Generic Instrument, QoDoS, for Assessing the Quality of Decision Making.

    PubMed

    Donelan, Ronan; Walker, Stuart; Salek, Sam

    2016-01-01

    The impact of decision-making during the development and the regulatory review of medicines greatly influences the delivery of new medicinal products. Currently, there is no generic instrument that can be used to assess the quality of decision-making. This study describes the development of the Quality of Decision-Making Orientation Scheme QoDoS(©) instrument for appraising the quality of decision-making. Semi-structured interviews about decision-making were carried out with 29 senior decision makers from the pharmaceutical industry (10), regulatory authorities (9) and contract research organizations (10). The interviews offered a qualified understanding of the subjective decision-making approach, influences, behaviors and other factors that impact such processes for individuals and organizations involved in the delivery of new medicines. Thematic analysis of the transcribed interviews was carried out using NVivo8® software. Content validity was carried out using qualitative and quantitative data by an expert panel, which led to the developmental version of the QoDoS. Further psychometric evaluations were performed, including factor analysis, item reduction, reliability testing and construct validation. The thematic analysis of the interviews yielded a 94-item initial version of the QoDoS(©) with a 5-point Likert scale. The instrument was tested for content validity using a panel of experts for language clarity, completeness, relevance and scaling, resulting in a favorable agreement by panel members with an intra-class correlation coefficient value of 0.89 (95% confidence interval = 0.56, 0.99). A 76-item QoDoS(©) (version 2) emerged from content validation. Factor analysis produced a 47-item measure with four domains. The 47-item QoDoS(©) (version 3) showed high internal consistency (n = 120, Cronbach's alpha = 0.89), high reproducibility (n = 20, intra-class correlation = 0.77) and a mean completion time of 10 min. Reliability testing and construct validation was successfully performed. The QoDoS(©) is both reliable and valid for use. It has the potential for extensive use in medicines development by both the pharmaceutical industry and regulatory authorities. The QoDoS(©) can be used to assess the quality of decision-making and to inform decision makers of the factors that influence decision-making.

  10. Validity and reliability of a novel immunosuppressive adverse effects scoring system in renal transplant recipients.

    PubMed

    Meaney, Calvin J; Arabi, Ziad; Venuto, Rocco C; Consiglio, Joseph D; Wilding, Gregory E; Tornatore, Kathleen M

    2014-06-12

    After renal transplantation, many patients experience adverse effects from maintenance immunosuppressive drugs. When these adverse effects occur, patient adherence with immunosuppression may be reduced and impact allograft survival. If these adverse effects could be prospectively monitored in an objective manner and possibly prevented, adherence to immunosuppressive regimens could be optimized and allograft survival improved. Prospective, standardized clinical approaches to assess immunosuppressive adverse effects by health care providers are limited. Therefore, we developed and evaluated the application, reliability and validity of a novel adverse effects scoring system in renal transplant recipients receiving calcineurin inhibitor (cyclosporine or tacrolimus) and mycophenolic acid based immunosuppressive therapy. The scoring system included 18 non-renal adverse effects organized into gastrointestinal, central nervous system and aesthetic domains developed by a multidisciplinary physician group. Nephrologists employed this standardized adverse effect evaluation in stable renal transplant patients using physical exam, review of systems, recent laboratory results, and medication adherence assessment during a clinic visit. Stable renal transplant recipients in two clinical studies were evaluated and received immunosuppressive regimens comprised of either cyclosporine or tacrolimus with mycophenolic acid. Face, content, and construct validity were assessed to document these adverse effect evaluations. Inter-rater reliability was determined using the Kappa statistic and intra-class correlation. A total of 58 renal transplant recipients were assessed using the adverse effects scoring system confirming face validity. Nephrologists (subject matter experts) rated the 18 adverse effects as: 3.1 ± 0.75 out of 4 (maximum) regarding clinical importance to verify content validity. The adverse effects scoring system distinguished 1.75-fold increased gastrointestinal adverse effects (p=0.008) in renal transplant recipients receiving tacrolimus and mycophenolic acid compared to the cyclosporine regimen. This finding demonstrated construct validity. Intra-class correlation was 0.81 (95% confidence interval: 0.65-0.90) and Kappa statistic of 0.68 ± 0.25 for all 18 adverse effects and verified substantial inter-rater reliability. This immunosuppressive adverse effects scoring system in stable renal transplant recipients was evaluated and substantiated face, content and construct validity with inter-rater reliability. The scoring system may facilitate prospective, standardized clinical monitoring of immunosuppressive adverse drug effects in stable renal transplant recipients and improve medication adherence.

  11. Network formation in a multi-asset artificial stock market

    NASA Astrophysics Data System (ADS)

    Wu, Songtao; He, Jianmin; Li, Shouwei; Wang, Chao

    2018-04-01

    A multi-asset artificial stock market is developed. In the market, stocks are assigned to a number of sectors and traded by heterogeneous investors. The mechanism of continuous double auction is employed to clear order book and form daily closed prices. Simulation results of prices at the sector level show an intra-sector similarity and inter-sector distinctiveness, and returns of individual stocks have stylized facts that are ubiquitous in the real-world stock market. We find that the market risk factor has critical impact on both network topology transition and connection formation, and that sector risk factors account for the formation of intra-sector links and sector-based local interaction. In addition, the number of community in threshold-based networks is correlated negatively and positively with the value of correlation coefficients and the ratio of intra-sector links, which are respectively determined by intensity of sector risk factors and the number of sectors.

  12. Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm.

    PubMed

    Menéndez, Lumila Paula

    2017-05-01

    Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other. Systematic error was tested through repeated measures ANOVA (ANOVA-RM), while random error through intraclass correlation coefficient. Results showed that the largest differences between the three observations were found in the first dataset. Some anatomical points like nasion, ectoconchion, temporosphenoparietal, asterion, and temporomandibular presented the highest INTRA-OE. In the second dataset, local distances had higher INTRA-OE than global distances while the third dataset showed the lowest INTRA-OE. © 2016 American Academy of Forensic Sciences.

  13. The quadrant method measuring four points is as a reliable and accurate as the quadrant method in the evaluation after anatomical double-bundle ACL reconstruction.

    PubMed

    Mochizuki, Yuta; Kaneko, Takao; Kawahara, Keisuke; Toyoda, Shinya; Kono, Norihiko; Hada, Masaru; Ikegami, Hiroyasu; Musha, Yoshiro

    2017-11-20

    The quadrant method was described by Bernard et al. and it has been widely used for postoperative evaluation of anterior cruciate ligament (ACL) reconstruction. The purpose of this research is to further develop the quadrant method measuring four points, which we named four-point quadrant method, and to compare with the quadrant method. Three-dimensional computed tomography (3D-CT) analyses were performed in 25 patients who underwent double-bundle ACL reconstruction using the outside-in technique. The four points in this study's quadrant method were defined as point1-highest, point2-deepest, point3-lowest, and point4-shallowest, in femoral tunnel position. Value of depth and height in each point was measured. Antero-medial (AM) tunnel is (depth1, height2) and postero-lateral (PL) tunnel is (depth3, height4) in this four-point quadrant method. The 3D-CT images were evaluated independently by 2 orthopaedic surgeons. A second measurement was performed by both observers after a 4-week interval. Intra- and inter-observer reliability was calculated by means of intra-class correlation coefficient (ICC). Also, the accuracy of the method was evaluated against the quadrant method. Intra-observer reliability was almost perfect for both AM and PL tunnel (ICC > 0.81). Inter-observer reliability of AM tunnel was substantial (ICC > 0.61) and that of PL tunnel was almost perfect (ICC > 0.81). The AM tunnel position was 0.13% deep, 0.58% high and PL tunnel position was 0.01% shallow, 0.13% low compared to quadrant method. The four-point quadrant method was found to have high intra- and inter-observer reliability and accuracy. This method can evaluate the tunnel position regardless of the shape and morphology of the bone tunnel aperture for use of comparison and can provide measurement that can be compared with various reconstruction methods. The four-point quadrant method of this study is considered to have clinical relevance in that it is a detailed and accurate tool for evaluating femoral tunnel position after ACL reconstruction. Case series, Level IV.

  14. A novel scoring system to measure radiographic abnormalities and related spirometric values in cured pulmonary tuberculosis.

    PubMed

    Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes

    2013-01-01

    Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67-0.95) and 0.78 (CI:95%, 0.65-0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71-0.95), and for the second measurement was 0.74 (CI:95%, 0.58-0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and exhibited good reliability and reproducibility. As intra-observer and inter-observer agreement of the SRA varied from good to excellent, the use of SRA in this setting appears acceptable.

  15. A Novel Scoring System to Measure Radiographic Abnormalities and Related Spirometric Values in Cured Pulmonary Tuberculosis

    PubMed Central

    Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes

    2013-01-01

    Background Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. Objective To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. Methods One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. Results The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67–0.95) and 0.78 (CI:95%, 0.65–0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71–0.95), and for the second measurement was 0.74 (CI:95%, 0.58–0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. Conclusion The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and exhibited good reliability and reproducibility. As intra-observer and inter-observer agreement of the SRA varied from good to excellent, the use of SRA in this setting appears acceptable. PMID:24223865

  16. Validity and Reliability of 10-Hz Global Positioning System to Assess In-line Movement and Change of Direction.

    PubMed

    Nikolaidis, Pantelis T; Clemente, Filipe M; van der Linden, Cornelis M I; Rosemann, Thomas; Knechtle, Beat

    2018-01-01

    The objectives of the present study were to examine the validity and reliability of the 10 Hz Johan GPS unit in assessing in-line movement and change of direction. The validity was tested against the criterion measure of 200 m track-and-field (track-and-field athletes, n = 8) and 20 m shuttle run endurance test (female soccer players, n = 20). Intra-unit and inter-unit reliability was tested by intra-class correlation coefficient (ICC) and coefficient of variation (CV), respectively. An analysis of variance examined differences between the GPS measurement and five laps of 200 m at 15 km/h, and t -test examined differences between the GPS measurement and 20 m shuttle run endurance test. The difference between the GPS measurement and 200 m distance ranged from -0.13 ± 3.94 m (95% CI -3.42; 3.17) in the first lap to 2.13 ± 2.64 m (95% CI -0.08; 4.33) in the fifth lap. A good intra-unit reliability was observed in 200 m (ICC = 0.833, 95% CI 0.535; 0.962). Inter-unit CV ranged from 1.31% (fifth lap) to 2.20% (third lap). The difference between the GPS measurement and 20 m shuttle run endurance test ranged from 0.33 ± 4.16 m (95% CI -10.01; 10.68) in 11.5 km/h to 9.00 ± 5.30 m (95% CI 6.44; 11.56) in 8.0 km/h. A moderate intra-unit reliability was shown in the second and third stage of the 20 m shuttle run endurance test (ICC = 0.718, 95% CI 0.222;0.898) and good reliability in the fifth, sixth, seventh and eighth (ICC = 0.831, 95% CI -0.229;0.996). Inter-unit CV ranged from 2.08% (11.5 km/h) to 3.92% (8.5 km/h). Based on these findings, it was concluded that the 10 Hz Johan system offers an affordable valid and reliable tool for coaches and fitness trainers to monitor training and performance.

  17. Reliability, repeatability, and reproducibility of pulmonary transit time assessment by contrast enhanced echocardiography.

    PubMed

    Herold, Ingeborg H F; Saporito, Salvatore; Bouwman, R Arthur; Houthuizen, Patrick; van Assen, Hans C; Mischi, Massimo; Korsten, Hendrikus H M

    2016-01-05

    The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.

  18. Inter-study reproducibility of cardiovascular magnetic resonance tagging

    PubMed Central

    2013-01-01

    Background The aim of this study is to determine the test-retest reliability of the measurement of regional myocardial function by cardiovascular magnetic resonance (CMR) tagging using spatial modulation of magnetization. Methods Twenty-five participants underwent CMR tagging twice over 12 ± 7 days. To assess the role of slice orientation on strain measurement, two healthy volunteers had a first exam, followed by image acquisition repeated with slices rotated ±15 degrees out of true short axis, followed by a second exam in the true short axis plane. To assess the role of slice location, two healthy volunteers had whole heart tagging. The harmonic phase (HARP) method was used to analyze the tagged images. Peak midwall circumferential strain (Ecc), radial strain (Err), Lambda 1, Lambda 2, and Angle α were determined in basal, mid and apical slices. LV torsion, systolic and early diastolic circumferential strain and torsion rates were also determined. Results LV Ecc and torsion had excellent intra-, interobserver, and inter-study intra-class correlation coefficients (ICC range, 0.7 to 0.9). Err, Lambda 1, Lambda 2 and angle had excellent intra- and interobserver ICC than inter-study ICC. Angle had least inter-study reproducibility. Torsion rates had superior intra-, interobserver, and inter-study reproducibility to strain rates. The measurements of LV Ecc were comparable in all three slices with different short axis orientations (standard deviation of mean Ecc was 0.09, 0.18 and 0.16 at basal, mid and apical slices, respectively). The mean difference in LV Ecc between slices was more pronounced in most of the basal slices compared to the rest of the heart. Conclusions Intraobserver and interobserver reproducibility of all strain and torsion parameters was excellent. Inter-study reproducibility of CMR tagging by SPAMM varied between different parameters as described in the results above and was superior for Ecc and LV torsion. The variation in LV Ecc measurement due to altered slice orientation is negligible compared to the variation due to slice location. Trial registration This trial is registered as NCT00005487 at National Heart, Lung and Blood institute. PMID:23663535

  19. Designing bovine T-cell vaccines via reverse immunology

    USDA-ARS?s Scientific Manuscript database

    T-cell responses contribute to immunity against many intra-cellular infections. There is, for example, strong evidence that major histocompatibility complex (MHC) class I restricted cytotoxic T lymphocytes (CTLs) play an essential role in mediating immunity to East Coast fever (ECF), a fatal lymphop...

  20. Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.

    PubMed

    Ye, L; Zhou, X; Li, J; Jin, J

    2011-09-01

    Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p < 0.001). Mean intra-operative blood loss was 121 and 420 ml, respectively (t = 28.944, p < 0.001), a significant difference. Both techniques achieved complete tumour resection with minimal damage to adjacent tissues, and no recurrence in any patient. Coblation successfully achieves transnasal endoscopic resection of juvenile nasopharyngeal angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.

  1. Assessment and validation of CT scanogram to compare per-operative and post-operative mechanical axis after navigated total knee replacement

    PubMed Central

    Jain, Sunil

    2008-01-01

    Our objective was to assess and validate low-dose computed tomography (CT) scanogram as a post-operative imaging modality to measure the mechanical axis after navigated total knee replacement. A prospective study was performed to compare intra-operative and post-operative mechanical axis after navigated total knee replacements. All consecutive patients who underwent navigated total knee replacement between May and December 2006 were included. The intra-operative final axis was recorded, and post-operatively a CT scanogram of lower limbs was performed. The mechanical axis was measured and compared against the intra-operative measurement. There were 15 patients ranging in age from 57 to 80 (average 70) years. The average final intra-operative axis was 0.56° varus (4° varus to 1.5° valgus) and post-operative CT scanogram axis was 0.52° varus (3.1° varus to 1.8° valgus). The average deviation from final axes to CT scanogram axes was 0.12° valgus with a correlation coefficient of 0.9. Our study suggests that CT scanogram is an imaging modality with reasonable accuracy for measuring mechanical axis despite significantly low radiation. It also confirms a high level of correlation between intra-operative and post-operative mechanical axis after navigated total knee replacement. PMID:18696064

  2. MRI of the sacroiliac joints in spondyloarthritis: the added value of intra-articular signal changes for a 'positive MRI'.

    PubMed

    Laloo, Frederiek; Herregods, N; Jaremko, J L; Verstraete, K; Jans, L

    2018-05-01

    To determine if intra-articular signal changes at the sacroiliac joint space on MRI have added diagnostic value for spondyloarthritis, when compared to bone marrow edema (BME). A retrospective study was performed on the MRIs of sacroiliac joints of 363 patients, aged 16-45 years, clinically suspected of sacroiliitis. BME of the sacroiliac joints was correlated to intra-articular sacroiliac joint MR signal changes: high T1 signal, fluid signal, ankylosis and vacuum phenomenon (VP). These MRI findings were correlated with final clinical diagnosis. Sensitivity (SN), specificity (SP), likelihood ratios (LR), predictive values and post-test probabilities were calculated. BME had SN of 68.9%, SP of 74.0% and LR+ of 2.6 for diagnosis of spondyloarthritis. BME in absence of intra-articular signal changes had a lower SN and LR+ for spondyloarthritis (SN = 20.5%, LR+ 1.4). Concomitant BME and high T1 signal (SP = 97.2%, LR + = 10.5), BME and fluid signal (SP = 98.6%, LR + = 10.3) or BME and ankylosis (SP = 100%) had higher SP and LR+ for spondyloarthritis. Concomitant BME and VP had low LR+ for spondyloarthritis (SP = 91%, LR + =0.9). When BME was absent, intra-articular signal changes were less prevalent, but remained highly specific for spondyloarthritis. Our results suggest that both periarticular and intra-articular MR signal of the sacroiliac joint should be examined to determine whether an MRI is 'positive' or 'not positive' for sacroiliitis associated with spondyloarthritis.

  3. Perianth organization and intra-specific floral variability.

    PubMed

    Herrera, J; Arista, M; Ortiz, P L

    2008-11-01

    Floral symmetry and fusion of perianth parts are factors that contribute to fine-tune the match between flowers and their animal pollination vectors. In the present study, we investigated whether the possession of a sympetalous (fused) corolla and bilateral symmetry of flowers translate into decreased intra-specific variability as a result of natural stabilizing selection exerted by pollinators. Average size of the corolla and intra-specific variability were determined in two sets of southern Spanish entomophilous plant species. In the first set, taxa were paired by family to control for the effect of phylogeny (phylogenetically independent contrasts), whereas in the second set species were selected at random. Flower size data from a previous study (with different species) were also used to test the hypothesis that petal fusion contributes to decrease intra-specific variability. In the phylogenetically independent contrasts, floral symmetry was a significant correlate of intra-specific variation, with bilaterally symmetrical flowers showing more constancy than radially symmetrical flowers (i.e. unsophisticated from a functional perspective). As regards petal fusion, species with fused petals were on average more constant than choripetalous species, but the difference was not statistically significant. The reanalysis of data from a previous study yielded largely similar results, with a distinct effect of symmetry on variability, but no effect of petal fusion. The randomly-chosen species sample, on the other hand, failed to reveal any significant effect of either symmetry or petal fusion on intra-specific variation. The problem of low-statistical power in this kind of analysis, and the difficulty of testing an evolutionary hypothesis that involves phenotypic traits with a high degree of morphological correlation is discussed.

  4. Cross-Cultural Adaptation, Reliability and Validity of the Danish Version of the Readiness for Return to Work Instrument.

    PubMed

    Stapelfeldt, Christina Malmose; Momsen, Anne-Mette Hedeager; Lund, Thomas; Grønborg, Therese Koops; Hogg-Johnson, Sheilah; Jensen, Chris; Skakon, Janne; Labriola, Merete

    2018-06-06

    The objective of the present study was to translate and validate the Canadian Readiness for Return To Work instrument (RRTW-CA) into a Danish version (RRTWDK) by testing its test-retest and internal consistency reliability and its structural and construct validity. Cross-cultural adaptation of the six-staged RRTW-CA instrument was performed in a standardised, systematic five-step-procedure; forward translation, panel synthesis of the translation, back translation, consolidation and revision by researchers, and finally pre-testing. This RRTW-DK beta-version was tested for its psychometric properties by intra-class correlation coefficient and standard error of measurement (n = 114), Cronbach's alpha (n = 471), confirmatory factor analyses (n = 373), and Spearman's rank correlation coefficient (n = 436) in sickness beneficiaries from a municipal employment agency and hospital wards. The original RRTW-CA stage structure could not be confirmed in the RRTWDK. The psychometric properties were thus inconclusive. The RRTW-DK cannot be recommended for use in the current version as the RRTW construct is questionable. The RRTW construct needs further exploration, preferably in a population that is homogeneous with regard to cause of sickness, disability duration and age.

  5. Test-retest reliability of the irrational performance beliefs inventory.

    PubMed

    Turner, M J; Slater, M J; Dixon, J; Miller, A

    2018-02-01

    The irrational performance beliefs inventory (iPBI) was developed to measure irrational beliefs within performance domains such as sport, academia, business, and the military. Past research indicates that the iPBI has good construct, concurrent, and predictive validity, but the test-retest reliability of the iPBI has not yet been examined. Therefore, in the present study the iPBI was administered to university sport and exercise students (n = 160) and academy soccer athletes (n = 75) at three-time points. Time point two occurred 7 days after time point one, and time point three occurred 21 days after time point two. In addition, social desirability was also measured. Repeated-measures MANCOVAs, intra-class coefficients, and Pearson's (r) correlations demonstrate that the iPBI has good test-retest reliability, with iPBI scores remaining stable across the three-time points. Pearson's correlation coefficients revealed no relationships between the iPBI and social desirability, indicating that the iPBI is not highly susceptible to response bias. The results are discussed with reference to the continued usage and development of the iPBI, and future research recommendations relating to the investigation of irrational performance beliefs are proposed.

  6. Development and evaluation of an audiology app for iPhone/iPad mobile devices.

    PubMed

    Larrosa, Francisco; Rama-Lopez, Julio; Benitez, Jesus; Morales, Jose M; Martinez, Asuncion; Alañon, Miguel A; Arancibia-Tagle, Diego; Batuecas-Caletrio, Angel; Martinez-Lopez, Marta; Perez-Fernandez, Nicolas; Gimeno, Carlos; Ispizua, Angel; Urrutikoetxea, Alberto; Rey-Martinez, Jorge

    2015-01-01

    The application described in this study appears to be accurate and valid, thus allowing calculation of a hearing handicap and assessment of the pure-tone air conduction threshold with iPhone/iPad devices. To develop and evaluate a newly developed professional, computer-based hearing handicap calculator and a manual hearing sensitivity assessment test for the iPhone and iPad (AudCal). Multi-center prospective non-randomized validation study. One hundred and ten consecutive adult participants underwent two hearing evaluations, a standard audiometry and a pure-tone air conduction test using AudCal with an iOS device. The hearing handicap calculation accuracy was evaluated comparing AudCal vs a web-based calculator. Hearing loss was found in 83 and 84 out of 220 standard audiometries and AudCal hearing tests (Cohen's Kappa = 0.89). The mean difference between AudCal and standard audiogram thresholds was -0.21 ± 6.38 dB HL. Excellent reliability and concordance between standard audiometry and the application's hearing loss assessment test were obtained (Cronbach's alpha = 0.96; intra-class correlation coefficient = 0.93). AudCal vs a web-based calculator were perfectly correlated (Pearson's r = 1).

  7. Central Corneal Thickness Reproducibility among Ten Different Instruments.

    PubMed

    Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco

    2016-11-01

    To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.

  8. Association between neurotrophin 4 and long-chain polyunsaturated fatty acid levels in mid-trimester amniotic fluid.

    PubMed

    Benn, Kiesha; Passos, Mariana; Jayaram, Aswathi; Harris, Mary; Bongiovanni, Ann Marie; Skupski, Daniel; Witkin, Steven S

    2014-11-01

    The omega-3 long-chain polyunsaturated fatty acid (LCPUFA) docosahexaenoic acid (DHA) and the omega-6 LCPUFA arachidonic acid (AA) are essential nervous system components that increase in concentration throughout gestation. The neurotrophins, brain-derived neurotrophic factor (BDNF), nerve growth factor (NGF), neurotrophin 3 (NT3), and neurotrophin 4 (NT4) are small basic peptides crucial for fetal brain development. The DHA supplementation during pregnancy has been suggested to enhance neural development. We evaluated whether amniotic fluid DHA and AA concentrations correlated with intra-amniotic neurotrophin levels. Amniotic fluid, obtained at 15 to 19 weeks gestation from 62 women, was tested for BDNF, NGF, NT3, and NT4 by enzyme-linked immunosorbent assay. Concentrations of DHA and AA, and saturated and monounsaturated fatty acids, were determined by gas chromatography. Associations were analyzed by the Spearman rank correlation test. Median levels of AA and DHA were 2.3% and 1.3% of the total intra-amniotic fatty acids, respectively. Median neurotrophin levels (pg/mL) were 36.7 for NT3, 26.8 for BDNF, 5.2 for NT4, and 0.8 for NGF. Intra-amniotic NT4 and BDNF levels were correlated (P = .0016), while NT3 and NGF levels were unrelated to each other or to BDNF or NT4. Only NT4 was positively correlated with amniotic fluid DHA (P < .0001) and AA (P = .0003) concentrations. There were no associations between DHA, AA, or any neurotrophin and maternal age, gestational age at time of amniocentesis, amniocentesis indication, parity, or gestational age at delivery. Elevations in intra-amniotic NT4 with increasing levels of DHA and AA suggest that these LCPUFAs may specifically influence the extent of NT4-mediated fetal brain neurogenesis. © The Author(s) 2014.

  9. Investigating the neural bases for intra-subject cognitive efficiency changes using functional magnetic resonance imaging

    PubMed Central

    Rao, Neena K.; Motes, Michael A.; Rypma, Bart

    2014-01-01

    Several fMRI studies have examined brain regions mediating inter-subject variability in cognitive efficiency, but none have examined regions mediating intra-subject variability in efficiency. Thus, the present study was designed to identify brain regions involved in intra-subject variability in cognitive efficiency via participant-level correlations between trial-level reaction time (RT) and trial-level fMRI BOLD percent signal change on a processing speed task. On each trial, participants indicated whether a digit-symbol probe-pair was present or absent in an array of nine digit-symbol probe-pairs while fMRI data were collected. Deconvolution analyses, using RT time-series models (derived from the proportional scaling of an event-related hemodynamic response function model by trial-level RT), were used to evaluate relationships between trial-level RTs and BOLD percent signal change. Although task-related patterns of activation and deactivation were observed in regions including bilateral occipital, bilateral parietal, portions of the medial wall such as the precuneus, default mode network regions including anterior cingulate, posterior cingulate, bilateral temporal, right cerebellum, and right cuneus, RT-BOLD correlations were observed in a more circumscribed set of regions. Positive RT-BOLD correlations, where fast RTs were associated with lower BOLD percent signal change, were observed in regions including bilateral occipital, bilateral parietal, and the precuneus. RT-BOLD correlations were not observed in the default mode network indicating a smaller set of regions associated with intra-subject variability in cognitive efficiency. The results are discussed in terms of a distributed area of regions that mediate variability in the cognitive efficiency that might underlie processing speed differences between individuals. PMID:25374527

  10. Investigating the neural bases for intra-subject cognitive efficiency changes using functional magnetic resonance imaging.

    PubMed

    Rao, Neena K; Motes, Michael A; Rypma, Bart

    2014-01-01

    Several fMRI studies have examined brain regions mediating inter-subject variability in cognitive efficiency, but none have examined regions mediating intra-subject variability in efficiency. Thus, the present study was designed to identify brain regions involved in intra-subject variability in cognitive efficiency via participant-level correlations between trial-level reaction time (RT) and trial-level fMRI BOLD percent signal change on a processing speed task. On each trial, participants indicated whether a digit-symbol probe-pair was present or absent in an array of nine digit-symbol probe-pairs while fMRI data were collected. Deconvolution analyses, using RT time-series models (derived from the proportional scaling of an event-related hemodynamic response function model by trial-level RT), were used to evaluate relationships between trial-level RTs and BOLD percent signal change. Although task-related patterns of activation and deactivation were observed in regions including bilateral occipital, bilateral parietal, portions of the medial wall such as the precuneus, default mode network regions including anterior cingulate, posterior cingulate, bilateral temporal, right cerebellum, and right cuneus, RT-BOLD correlations were observed in a more circumscribed set of regions. Positive RT-BOLD correlations, where fast RTs were associated with lower BOLD percent signal change, were observed in regions including bilateral occipital, bilateral parietal, and the precuneus. RT-BOLD correlations were not observed in the default mode network indicating a smaller set of regions associated with intra-subject variability in cognitive efficiency. The results are discussed in terms of a distributed area of regions that mediate variability in the cognitive efficiency that might underlie processing speed differences between individuals.

  11. Corpus Callosum Size, Reaction Time Speed and Variability in Mild Cognitive Disorders and in a Normative Sample

    ERIC Educational Resources Information Center

    Anstey, Kaarin J.; Mack, Holly A.; Christensen, Helen; Li, Shu-Chen; Reglade-Meslin, Chantal; Maller, Jerome; Kumar, Rajeev; Dear, Keith; Easteal, Simon; Sachdev, Perminder

    2007-01-01

    Intra-individual variability in reaction time increases with age and with neurological disorders, but the neural correlates of this increased variability remain uncertain. We hypothesized that both faster mean reaction time (RT) and less intra-individual RT variability would be associated with larger corpus callosum (CC) size in older adults, and…

  12. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    PubMed Central

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent–teacher and 19 mother–father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent–teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother–father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings. PMID:24994985

  13. Is intra-bladder pressure measurement a reliable indicator for raised intra-abdominal pressure? A prospective comparative study.

    PubMed

    Al-Abassi, Abdulla Ahmed; Al Saadi, Azan Saleh; Ahmed, Faisal

    2018-06-19

    Intra-abdominal pressure (IAP) can be measured by several indirect methods; however, the urinary bladder is largely preferred. The aim of this study was to compare intra-bladder pressure (IBP) at different levels of IAPs and assess its reliability as an indirect method for IAP measurement. We compared IBP with IAP in twenty-one patients undergoing laparoscopic cholecystectomy under general anesthesia. Measurements were recorded at increasing levels of insufflation pressures to approximately 22 mmHg. Pearson's correlation coefficient was calculated to establish the relationship between the two pressure measurements and Bland-Altman analysis was used to assess the limits of agreement between the two methods of measurements. The urinary bladder pressures reflected well the pressures in the abdominal cavity. Pearson correlation coefficient showed a good correlation between the two measurement techniques (r = 0.966, p < 0.0001) and Bland-Altman analysis indicated that the 95% limits of agreement between the two methods ranged from - 2.83 to 2.64. This range is accepted both clinically and according to the recommendations of the World Society of Abdominal Compartment Syndrome (WSACS). Our study showed that IBP measurement is a simple, minimally invasive method that may reliably estimates IAP in patients placed in supine position. Measurements for pressures higher than 12 mmHg may be less reliable. When applied clinically, this should alert the clinician to take safety measures to avoid abdominal compartment syndrome (ACS).

  14. Ultraperformance convergence chromatography-high resolution tandem mass spectrometry for lipid biomarker profiling and identification.

    PubMed

    Jones, Jace W; Carter, Claire L; Li, Fei; Yu, Jianshi; Pierzchalski, Keely; Jackson, Isabel L; Vujaskovic, Zeljko; Kane, Maureen A

    2017-03-01

    Lipids represent biologically ubiquitous and highly dynamic molecules in terms of abundance and structural diversity. Whereas the potential for lipids to inform on disease/injury is promising, their unique characteristics make detection and identification of lipids from biological samples analytically demanding. We report the use of ultraperformance convergence chromatography (UPC 2 ), a variant of supercritical fluid chromatography, coupled to high-resolution, data-independent tandem mass spectrometry for characterization of total lipid extracts from mouse lung tissue. The UPC 2 platform resulted in lipid class separation and when combined with orthogonal column chemistries yielded chromatographic separation of intra-class species based on acyl chain hydrophobicity. Moreover, the combined approach of using UPC 2 with orthogonal column chemistries, accurate mass measurements, time-aligned low- and high-collision energy total ion chromatograms, and positive and negative ion mode product ion spectra correlation allowed for confident lipid identification. Of great interest was the identification of differentially expressed ceramides that were elevated 24 h post whole thorax lung irradiation. The identification of lipids that were elevated 24 h post-irradiation signifies a unique opportunity to investigate early mechanisms of action prior to the onset of clinical symptoms in the whole thorax lung irradiation mouse model. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Efficacy of hepatic arterial infusion chemotherapy in advanced hepatocellular carcinoma

    PubMed Central

    Baek, Yang Hyun; Kim, Kyoung Tae; Lee, Sung Wook; Jeong, Jin Sook; Park, Byeong Ho; Nam, Kyung Jin; Cho, Jin Han; Kim, Young Hoon; Roh, Young Hoon; Lee, Hyung Sik; Choi, Young Min; Han, Sang Young

    2012-01-01

    AIM: To investigate the efficacy of hepatic arterial infusion chemotherapy (HAIC) using floxuridine (FUDR) in patients with advanced hepatocellular carcinoma (HCC) confined to the liver. METHODS: Thirty-four patients who had advanced HCC with unresectability or unsuccessful previous therapy in the absence of extrahepatic metastasis were treated with intra-arterial FUDR chemotherapy at our hospital between March 2005 and May 2008. Among the 34 patients, 9 patients were classified as Child class C, and 18 patients had portal vein tumor thrombus (PVTT). One course of chemotherapy consisted of continuous infusion of FUDR (0.3 mg/kg during day 1-14) and dexamethasone (10 mg on day 1, 4, 7 and 11), and this treatment was repeated every 28 d. RESULTS: Two patients (5.9%) displayed a complete response, and 12 patients (35.3%) had a partial response. The tumor control rate was 61.8%. The median overall survival times were 15.3 mo, 12.4 mo and 4.3 mo for the patients who were classified as Child class A, Child class B and Child class C, respectively (P = 0.0392). The progression-free survival was 12.9 mo, 7.7 mo and 2.6 mo for the patients who were classified as Child class A, Child class B and Child class C, respectively (P = 0.0443). The cumulative survival differed significantly according to the Child-Pugh classification and the presence of PVTT. In addition to hepatic reserve capacity and PVTT, the extent of HCC was an independent factor in determining a poor prognosis. The most common adverse reactions to HAIC were mucositis, diarrhea and peptic ulcer disease, but most of these complications were improved by medical treatment and/or a delay of HAIC. CONCLUSION: The present study demonstrates that intra-arterial FUDR chemotherapy is a safe and effective treatment for advanced HCC that is recalcitrant to other therapeutic modalities, even in patients with advanced cirrhosis. PMID:22807613

  16. Video-based face recognition via convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Bao, Tianlong; Ding, Chunhui; Karmoshi, Saleem; Zhu, Ming

    2017-06-01

    Face recognition has been widely studied recently while video-based face recognition still remains a challenging task because of the low quality and large intra-class variation of video captured face images. In this paper, we focus on two scenarios of video-based face recognition: 1)Still-to-Video(S2V) face recognition, i.e., querying a still face image against a gallery of video sequences; 2)Video-to-Still(V2S) face recognition, in contrast to S2V scenario. A novel method was proposed in this paper to transfer still and video face images to an Euclidean space by a carefully designed convolutional neural network, then Euclidean metrics are used to measure the distance between still and video images. Identities of still and video images that group as pairs are used as supervision. In the training stage, a joint loss function that measures the Euclidean distance between the predicted features of training pairs and expanding vectors of still images is optimized to minimize the intra-class variation while the inter-class variation is guaranteed due to the large margin of still images. Transferred features are finally learned via the designed convolutional neural network. Experiments are performed on COX face dataset. Experimental results show that our method achieves reliable performance compared with other state-of-the-art methods.

  17. The effect of post-traumatic-stress-disorder on intra-operative analgesia in a veteran population during cataract procedures carried out using retrobulbar or topical anesthesia: a retrospective study.

    PubMed

    Rapoport, Yuna; Wayman, Laura L; Chomsky, Amy S

    2017-06-07

    A growing proportion of veterans treated at the Veterans Health Administration (VA) have a history of post-traumatic-stress-disorder (PTSD), and there exists a higher rate of PTSD amongst veterans than the general population. The purpose of this study is to determine the correlation between PTSD and intra-operative analgesia, intra-operative time, and anesthesia type for cataract surgery in a veteran population. Secondary objectives are to determine if patient age, and first or second eye surgery affect intra-operative pain control or are correlated with type of anesthesia modality. A retrospective study of 330 cataract surgeries performed by resident physicians between January and September 2012 at the Veterans Affairs Medical Center Tennessee Valley Healthcare System, Nashville and Murfreesboro Campuses was completed. Three hundred and thirty veteran patients were selected if their cataract surgery was performed between January and September 2012. Combined cases were excluded. The primary outcome evaluated was intra-operative analgesia. Secondary outcomes included history of post-traumatic-stress-disorder, anesthesia type, first or second eye, pain control, intra-operative heart rate and blood pressure, age, and case complexity. Data was analyzed using an unpaired two-sample Welch's t-test assuming unequal variance and Z test of comparison of proportions. Patients with post-traumatic-stress-disorder reported higher pain scores, had longer operative times, and were more likely to have received a retrobulbar block. Operative time was not associated with an increased pain score, irrespective of anesthesia type, when controlled for PTSD. Complex cases had longer operative times, more sedation, and higher pain scores. P < 0.05 was used consistently. Post-traumatic stress disorder and anxiety are more prevalent in the veteran population. Our data suggests that a history of post-traumatic-stress-disorder was correlated with higher pain scores, longer operative times, and with having received a retrobulbar block. Patients without a history of PTSD were more likely to have received topical anesthesia with or without sedation. The veteran population requires more sedation to allay anxiety and perceptions of discomfort, which may account for longer surgical times. The veteran population is a special population and it is important to investigate how PTSD in the veteran population affects intra-operative analgesia.

  18. Scaling properties of foreign exchange volatility

    NASA Astrophysics Data System (ADS)

    Gençay, Ramazan; Selçuk, Faruk; Whitcher, Brandon

    2001-01-01

    In this paper, we investigate the scaling properties of foreign exchange volatility. Our methodology is based on a wavelet multi-scaling approach which decomposes the variance of a time series and the covariance between two time series on a scale by scale basis through the application of a discrete wavelet transformation. It is shown that foreign exchange rate volatilities follow different scaling laws at different horizons. Particularly, there is a smaller degree of persistence in intra-day volatility as compared to volatility at one day and higher scales. Therefore, a common practice in the risk management industry to convert risk measures calculated at shorter horizons into longer horizons through a global scaling parameter may not be appropriate. This paper also demonstrates that correlation between the foreign exchange volatilities is the lowest at the intra-day scales but exhibits a gradual increase up to a daily scale. The correlation coefficient stabilizes at scales one day and higher. Therefore, the benefit of currency diversification is the greatest at the intra-day scales and diminishes gradually at higher scales (lower frequencies). The wavelet cross-correlation analysis also indicates that the association between two volatilities is stronger at lower frequencies.

  19. A Novel Intra-body Sensor for Vaginal Temperature Monitoring

    PubMed Central

    Rodrigues, Joel J. P. C.; Caldeira, João; Vaidya, Binod

    2009-01-01

    Over the years some medical studies have tried to better understand the internal behavior of human beings. Many researchers in this domain have been striving to find relationships between intra-vaginal temperature and certain female health conditions, such as ovulation and fertile period since woman’s intra-vaginal temperature is one of the body parameters most preferred in such studies. However, due to lack of a appropriate technology, medical research devoted to studying correlations of such body parameters with certain womans’ body phenomena could not obtain better results. This article presents the design and implementation of a novel intra-body sensor for acquisition and monitoring of intra-vaginal temperatures. This novel intra-body sensor provides data collection that is used for studying the relation between temperature variations and female health conditions, such as anticipation and monitoring of the ovulation period, detection of pregnancy contractions, preterm labor prevention, etc.. The motivation for this work focuses on the development of this new intra-body sensor that will represent a major step in medical technology. The novel sensor was tested and validated on hospitalized women as well as normal healthy women. Finally our medical team has attested to the accuracy, usability and performance of this novel intra-body sensor. PMID:22574046

  20. Validation of EncephalApp, Smartphone-based Stroop Test, for the Diagnosis of Covert Hepatic Encephalopathy

    PubMed Central

    Bajaj, Jasmohan S; Heuman, Douglas M; Sterling, Richard K; Sanyal, Arun J; Siddiqui, Muhammad; Matherly, Scott; Luketic, Velimir; Stravitz, R Todd; Fuchs, Michael; Thacker, Leroy R; Gilles, HoChong; White, Melanie B; Unser, Ariel; Hovermale, James; Gavis, Edith; Noble, Nicole A; Wade, James B

    2014-01-01

    Background & Aims Detection of covert hepatic encephalopathy (CHE) is difficult but point of care testing could increase rates of diagnosis. We aimed to validate the ability of the smartphone app EncephalApp, a streamlined version of Stroop App, to detect CHE. We evaluated face validity, test–retest reliability, and external validity. Methods Patients with cirrhosis (n=167; 38% with overt HE [OHE]; mean age, 55 years; mean model for end-stage liver disease score, 12) and controls (n=114) were each given a paper and pencil cognitive battery (standard) along with EncephalApp. EncephalApp has Off and On states; results measured were: OffTime, OnTime, OffTime+OnTime, and number of runs required to complete 5 off and on runs. Thirty-six patients with cirrhosis underwent driving simulation tests, and EncephalApp results were correlated with results. Test–retest reliability was analyzed in a subgroup of patients. The test was performed before and after transjugular intra-hepatic portosystemic shunt placement, before and after correction for hyponatremia, to determine external validity. Results All patients with cirrhosis performed worse on paper and pencil and EncephalApp tests than controls. Patients with cirrhosis and OHE performed worse than those without OHE. Age-dependent EncephalApp cut-offs (younger or older than 45 years) were set. An OffTime+OnTime value of >190 seconds identified all patients with CHE with an area under the receiver operator characteristic (AUROC) value of 0.91; the AUROC value was 0.88 for diagnosis of CHE in those without OHE. EncephalApp times correlated with crashes and illegal turns in driving simulation tests. Test–retest reliability was high (intra-class coefficient, 0.83) among 30 patients retested 1–3 months apart. OffTime+OnTime increased significantly (206 vs 255, P=.007) among 10 patients retested 33±7 days after transjugular intra-hepatic portosystemic shunt placement. OffTime+OnTime decreased significantly (242 vs 225, P=.03) in 7 patients tested before and after correction for hyponatremia (126±3 to 132±4 meq/L, P=.01), 10±5 days apart. Conclusions A smartphone app called EncephalApp has good face validity, test–retest reliability, and external validity for the diagnosis of CHE. PMID:24846278

  1. A Peer-Reviewed Research Assignment for Large Classes.

    ERIC Educational Resources Information Center

    Henderson, LaRhee; Buising, Charisse

    2000-01-01

    Introduces a writing exercise students work on in collaborative groups. Aims to enhance students' scientific research paper writing skills and provide experience working in collaborative groups. Presents evaluation criteria for peer-group evaluation of a poster presentation, intra-group evaluation of peer performance, and peer-group evaluation of…

  2. Intra-abdominal fat: Comparison of computed tomography fat segmentation and bioimpedance spectroscopy.

    PubMed

    Finch, Peter

    2017-06-01

    Intra-abdominal fat is an important factor in determining the metabolic syndrome/insulin resistance, and thus the risk of diabetes and ischaemic heart disease. Computed Tomography (CT) fat segmentation represents a defined method of quantifying intra-abdominal fat, with attendant radiation risks. Bioimpedance spectroscopy may offer a method of assessment without any risks to the patients. A comparison is made of these two methods. This was a preliminary study of the utility of multifrequency bioimpedance spectroscopy of the mid abdomen as a measure of intra-abdominal fat, by comparison with fat segmentation of an abdominal CT scan in the -30 to -190 HU range. There was a significant (P < 0.01) correlation between intra-abdominal fat and mid-upper arm circumference, as well as the bioimpedance parameter, the R/S ratio. Multivariate analysis showed that these were the only independant variables and allowed the derivation of a formula to estimate intra-abdominal fat: IAF = 0.02 × MAC - 0.757 × R/S + 0.036. Circumabdominal bioimpedance spectroscopy may prove a useful method of assessing intra-abdominal fat, and may be suitable for use in studies to enhance other measures of body composition, such as mid-upper arm circumference.

  3. Reliability of concentrations of organophosphate pesticide metabolites in serial urine specimens from pregnancy in the Generation R study

    PubMed Central

    Spaan, Suzanne; Pronk, Anjoeka; Koch, Holger M.; Jusko, Todd A.; Jaddoe, Vincent W.V.; Shaw, Pamela A.; Tiemeier, Henning M.; Hofman, Albert; Pierik, Frank H.; Longnecker, Matthew P.

    2014-01-01

    The widespread use of organophosphate (OP) pesticides has resulted in ubiquitous exposure in humans, primarily through their diet. Exposure to OP pesticides may have adverse health effects, including neurobehavioral deficits in children. The optimal design of new studies requires data on the reliability of urinary measures of exposure. In the present study, urinary concentrations of six dialkyl phosphate (DAP) metabolites, the main urinary metabolites of OP pesticides, were determined in 120 pregnant women participating in the Generation R Study in Rotterdam. Intra-class correlation coefficients (ICCs) across serial urine specimens taken at <18, 18–25, and >25 weeks of pregnancy were determined to assess reliability. Geometric mean total DAP metabolite concentrations were 229 (GSD 2.2), 240 (GSD 2.1), and 224 (GSD 2.2) nmol/g creatinine across the three periods of gestation. Metabolite concentrations from the serial urine specimens in general correlated moderately. The ICCs for the six DAP metabolites ranged from 0.14 to 0.38 (0.30 for total DAPs), indicating weak to moderate reliability. Although the DAP metabolite levels observed in this study are slightly higher and slightly more correlated than in previous studies, the low to moderate reliability indicates a high degree of within-person variability, which presents challenges for designing well-powered epidemiologic studies. PMID:25515376

  4. Translation and cultural adaptation of the Manchester-Oxford Foot Questionnaire (MOXFQ) into Persian language.

    PubMed

    Mousavian, Alireza; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Omidi-Kashani, Farzad; Kachooei, Amir Reza

    2015-12-01

    In this study, we aimed to translate and test the validity and reliablity of the Persian version of the Manchester-Oxford Foot Questionnaire in foot and ankle patients. We translated the Manchester-Oxford Foot Questionnaire to Persian language according to the accepted guidelines, then assessed the psychometric properties including the validity and reliability on 308 patients with long-standing foot and ankle problems. To test the reliability, we calculated the intra-class correlation coefficient (ICC) for test-retest reliability and measured Cronbach's alpha to test the internal consistency. To test the construct validity of the Manchester-Oxford Foot Questionnaire we also administered the Short-Form 36 to patients. Construct validity was supported by significant correlation with SF36 subscales except for pain subscale of the persian MOXFQ with mental health of the SF36 (r=0.207). Intraclass correlation coefficient was 0.79 for the total MOXFQ and ranged from 0.83 to 0.89 for the three subscales. Cronbach's alpha for pain, walking/standing, and social interaction was 0.86, 0.88, and 0.89, respectively, and was 0.79 for the total MOXFQ showing good internal consistency in each domain. The Persian Manchester-Oxford Foot Questionnaire health scoring system is a valid and reliable patient-reported instrument for foot and ankle problems. Copyright © 2015. Published by Elsevier Ltd.

  5. The Maristán stigma scale: a standardized international measure of the stigma of schizophrenia and other psychoses.

    PubMed

    Saldivia, Sandra; Runte-Geidel, Ariadne; Grandón, Pamela; Torres-González, Francisco; Xavier, Miguel; Antonioli, Claudio; Ballester, Dinarte A; Melipillán, Roberto; Galende, Emiliano; Vicente, Benjamín; Caldas, José Miguel; Killaspy, Helen; Gibbons, Rachel; King, Michael

    2014-06-18

    People with schizophrenia face prejudice and discrimination from a number of sources including professionals and families. The degree of stigma perceived and experienced varies across cultures and communities. We aimed to develop a cross-cultural measure of the stigma perceived by people with schizophrenia. Items for the scale were developed from qualitative group interviews with people with schizophrenia in six countries. The scale was then applied in face-to-face interviews with 164 participants, 103 of which were repeated after 30 days. Principal Axis Factoring and Promax rotation evaluated the structure of the scale; Horn's parallel combined with bootstrapping determined the number of factors; and intra-class correlation assessed test-retest reliability. The final scale has 31 items and four factors: informal social networks, socio-institutional, health professionals and self-stigma. Cronbach's alpha was 0.84 for the Factor 1; 0.81 for Factor 2; 0.74 for Factor 3, and 0.75 for Factor 4. Correlation matrix among factors revealed that most were in the moderate range [0.31-0.49], with the strongest occurring between perception of stigma in the informal network and self-stigma and there was also a weaker correlation between stigma from health professionals and self-stigma. Test-retest reliability was highest for informal networks [ICC 0.76 [0.67 -0.83

  6. The Maristán stigma scale: a standardized international measure of the stigma of schizophrenia and other psychoses

    PubMed Central

    2014-01-01

    Background People with schizophrenia face prejudice and discrimination from a number of sources including professionals and families. The degree of stigma perceived and experienced varies across cultures and communities. We aimed to develop a cross-cultural measure of the stigma perceived by people with schizophrenia. Method Items for the scale were developed from qualitative group interviews with people with schizophrenia in six countries. The scale was then applied in face-to-face interviews with 164 participants, 103 of which were repeated after 30 days. Principal Axis Factoring and Promax rotation evaluated the structure of the scale; Horn’s parallel combined with bootstrapping determined the number of factors; and intra-class correlation assessed test-retest reliability. Results The final scale has 31 items and four factors: informal social networks, socio-institutional, health professionals and self-stigma. Cronbach’s alpha was 0.84 for the Factor 1; 0.81 for Factor 2; 0.74 for Factor 3, and 0.75 for Factor 4. Correlation matrix among factors revealed that most were in the moderate range [0.31-0.49], with the strongest occurring between perception of stigma in the informal network and self-stigma and there was also a weaker correlation between stigma from health professionals and self-stigma. Test-retest reliability was highest for informal networks [ICC 0.76 [0.67 -0.83

  7. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    PubMed

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  8. Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis

    PubMed Central

    Chamorro, Claudio; Armijo-Olivo, Susan; De la Fuente, Carlos; Fuentes, Javiera; Javier Chirosa, Luis

    2017-01-01

    Abstract The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors. PMID:29071305

  9. Correlation of dickkopf-1 concentrations in plasma and synovial fluid to the severity of radiographic signs of equine osteoarthritis.

    PubMed

    Mills, Jillian S; Kinsley, Marc A; Peters, Duncan F; Weber, Patty S D; Shearer, Tara R; Pease, Anthony P

    2017-09-12

    The purpose of this study was to determine whether there was a correlation between circulating and intra-synovial Dkk-1 and radiographic signs of equine osteoarthritis. Circulating and intra-synovial Dkk-1 levels were measured in clinical cases using a commercially available human Dkk-1 ELISA. Radiographs were performed of the joints from which fluid was collected and these were assessed and scored by a boarded radiologist for joint narrowing, subchondral bone sclerosis, subchondral bone lysis, and periarticular modelling. Comparisons were made between radiographic scores and the concentrations of Dkk-1 using a Kruskal-Wallis one-way ANOVA. Correlations were calculated using Kendall's statistic. A total of 42 synovial fluid samples from 21 horses were collected and used in the analysis. No significant correlation was identified between Dkk-1 concentrations and radiographic signs of osteoarthritis. Intra-synovial Dkk-1 concentrations were significantly greater (p <0.001) in low motion joints (mean concentration, 232.68 pg/mL; range, 109.07-317.17) when compared to high-motion joints (28.78 pg/mL; 0.05-186.44 pg/mL) (p <0.001). Low motion joints have significantly higher concentrations of Dkk-1 compared to high motion joints. Further research is needed to establish the importance of this finding and whether potential diagnostic or therapeutic applications of Dkk-1 exist in the horse.

  10. Pre-operative Duplex Ultrasonography in Arteriovenous Fistula Creation: Intra- and Inter-observer Agreement.

    PubMed

    Zonnebeld, Niek; Maas, Tommy M G; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M

    2017-11-01

    Although clinical guidelines on arteriovenous fistula (AVF) creation advocate minimum luminal arterial and venous diameters, assessed by duplex ultrasonography (DUS), the clinical value of routine DUS examination is under debate. DUS might be an insufficiently repeatable and/or reproducible imaging modality because of its operator dependency. The present study aimed to assess intra- and inter-observer agreement of DUS examination in support of AVF surgery planning. Ten end stage renal disease patients were included, to assess intra- and inter-observer agreement of pre-operative DUS measurements. All measurements were performed by two trained and experienced vascular technicians, blinded to measurement readings. From the routine DUS protocol, representative measurements (venous diameters, and arterial diameters and volume flow in the upper arm and forearm) were selected. For intra-observer agreement the measurements were performed in triplicate, with the probe released from the skin between each. Intraclass correlation coefficients were calculated for intra- and inter-observer agreement, and Bland-Altman plots used to graphically display mean measurement differences and limits of agreement. Ten patients (6 male, 59.4±19.7 years) consented to participate, and all predefined measurements were obtained. Intraclass correlation coefficients for intra-observer agreement of diameter measurements were at least 0.90 (95% CI 0.74-0.97; radial artery). Inter-observer agreement was at least 0.83 (0.46-0.96; lateral diameter upper arm cephalic vein). The Bland-Altman plots showed acceptable mean measurement differences and limits of agreement. In experienced hands, excellent intra- and inter-observer agreement can be reached for the discrete pre-operative DUS measurements advocated in clinical guidelines. DUS is therefore a reliable imaging modality to support AVF surgery planning. The content of DUS protocols, however, needs further standardisation. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  11. Outage probability of a relay strategy allowing intra-link errors utilizing Slepian-Wolf theorem

    NASA Astrophysics Data System (ADS)

    Cheng, Meng; Anwar, Khoirul; Matsumoto, Tad

    2013-12-01

    In conventional decode-and-forward (DF) one-way relay systems, a data block received at the relay node is discarded, if the information part is found to have errors after decoding. Such errors are referred to as intra-link errors in this article. However, in a setup where the relay forwards data blocks despite possible intra-link errors, the two data blocks, one from the source node and the other from the relay node, are highly correlated because they were transmitted from the same source. In this article, we focus on the outage probability analysis of such a relay transmission system, where source-destination and relay-destination links, Link 1 and Link 2, respectively, are assumed to suffer from the correlated fading variation due to block Rayleigh fading. The intra-link is assumed to be represented by a simple bit-flipping model, where some of the information bits recovered at the relay node are the flipped version of their corresponding original information bits at the source. The correlated bit streams are encoded separately by the source and relay nodes, and transmitted block-by-block to a common destination using different time slots, where the information sequence transmitted over Link 2 may be a noise-corrupted interleaved version of the original sequence. The joint decoding takes place at the destination by exploiting the correlation knowledge of the intra-link (source-relay link). It is shown that the outage probability of the proposed transmission technique can be expressed by a set of double integrals over the admissible rate range, given by the Slepian-Wolf theorem, with respect to the probability density function ( pdf) of the instantaneous signal-to-noise power ratios (SNR) of Link 1 and Link 2. It is found that, with the Slepian-Wolf relay technique, so far as the correlation ρ of the complex fading variation is | ρ|<1, the 2nd order diversity can be achieved only if the two bit streams are fully correlated. This indicates that the diversity order exhibited in the outage curve converges to 1 when the bit streams are not fully correlated. Moreover, the Slepian-Wolf outage probability is proved to be smaller than that of the 2nd order maximum ratio combining (MRC) diversity, if the average SNRs of the two independent links are the same. Exact as well as asymptotic expressions of the outage probability are theoretically derived in the article. In addition, the theoretical outage results are compared with the frame-error-rate (FER) curves, obtained by a series of simulations for the Slepian-Wolf relay system based on bit-interleaved coded modulation with iterative detection (BICM-ID). It is shown that the FER curves exhibit the same tendency as the theoretical results.

  12. An Investigation into the Relationship between Human Cranial and Pelvic Sexual Dimorphism.

    PubMed

    Best, Kaleigh C; Garvin, Heather M; Cabo, Luis L

    2017-10-16

    When faced with commingled remains, it might be assumed that a more "masculine" pelvis is associated with a more "masculine" cranium, but this relationship has not been specifically tested. This study uses geometric morphometric analyses of pelvic and cranial landmarks to assess whether there is an intra-individual relationship between the degrees of sexual expression in these two skeletal regions. Principal component and discriminant function scores were used to assess sexual dimorphism in 113 U.S. Black individuals. Correlation values and partial least squares regression (PLS) were used to evaluate intra-individual relationships. Results indicate that the os coxae is more sexually dimorphic than the cranium, with element shape being more sexually dimorphic than size. PLS and correlation results suggest no significant intra-individual relationship between pelvic and cranial sexual size or shape expression. Thus, in commingled situations, associations between these skeletal elements cannot be inferred based on degree of "masculinity." © 2017 American Academy of Forensic Sciences.

  13. Reliability and smallest real difference of the ankle lunge test post ankle fracture.

    PubMed

    Simondson, David; Brock, Kim; Cotton, Susan

    2012-02-01

    This study aimed to determine the reliability and the smallest real difference of the Ankle Lunge test in an ankle fracture patient population. In the post immobilisation stage of ankle fracture, ankle dorsiflexion is an important measure of progress and outcome. The Ankle Lunge test measures weight bearing dorsiflexion, resulting in negative scores (knee to wall distance) and positive scores (toe to wall distance), for which the latter has proven reliability in normal subjects only. A consecutive sample of ankle fracture patients with permission to commence weight bearing, were recruited to the study. Three measurements of the Ankle Lunge Test were performed each by two raters, one senior and one junior physiotherapist. These occurred prior to therapy sessions in the second week after plaster removal. A standardised testing station was utilised and allowed for both knee to wall distance and toe to wall distance measurement. Data was collected from 10 individuals with ankle fracture, with an average age of 36 years (SD 14.8). Seventy seven percent of observations were negative. Intra and inter-rater reliability yielded intra class correlations at or above 0.97, p < .001. There was a significant systematic bias towards improved scores during repeated measurement for one rater (p = .01). The smallest real difference was calculated as 13.8mm. The Ankle Lunge test is a practical and reliable tool for measuring weightbearing dorsiflexion post ankle fracture. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Reproducibility of a silicone-based test food to masticatory performance evaluation by different sieve methods.

    PubMed

    Sánchez-Ayala, Alfonso; Vilanova, Larissa Soares Reis; Costa, Marina Abrantes; Farias-Neto, Arcelino

    2014-01-01

    The aim of this study was to evaluate the reproducibility of the condensation silicone Optosil Comfort® as an artificial test food for masticatory performance evaluation. Twenty dentate subjects with mean age of 23.3±0.7 years were selected. Masticatory performance was evaluated using the simple (MPI), the double (IME) and the multiple sieve methods. Trials were carried out five times by three examiners: three times by the first, and once by the second and third examiners. Friedman's test was used to find the differences among time trials. Reproducibility was determined by the intra-class correlation (ICC) test (α=0.05). No differences among time trials were found, except for MPI-4 mm (p=0.022) from the first examiner results. The intra-examiner reproducibility (ICC) of almost all data was high (ICC≥0.92, p<0.001), being moderate only for MPI-0.50 mm (ICC=0.89, p<0.001). The inter-examiner reproducibility was high (ICC>0.93, p<0.001) for all results. For the multiple sieve method, the average mean of absolute difference from repeated measurements were lower than 1 mm. This trend was observed only from MPI-0.50 to MPI-1.4 for the single sieve method, and from IME-0.71/0.50 to IME-1.40/1.00 for the double sieve method. The results suggest that regardless of the method used, the reproducibility of Optosil Comfort® is high.

  15. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    PubMed

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  16. Measuring competence in endoscopic sinus surgery.

    PubMed

    Syme-Grant, J; White, P S; McAleer, J P G

    2008-02-01

    Competence based education is currently being introduced into higher surgical training in the UK. Valid and reliable performance assessment tools are essential to ensure competencies are achieved. No such tools have yet been reported in the UK literature. We sought to develop and pilot test an Endoscopic Sinus Surgery Competence Assessment Tool (ESSCAT). The ESSCAT was designed for in-theatre assessment of higher surgical trainees in the UK. The ESSCAT rating matrix was developed through task analysis of ESS procedures. All otolaryngology consultants and specialist registrars in Scotland were given the opportunity to contribute to its refinement. Two cycles of in-theatre testing were used to ensure utility and gather quantitative data on validity and reliability. Videos of trainees performing surgery were used in establishing inter-rater reliability. National consultation, the consensus derived minimum standard of performance, Cronbach's alpha = 0.89 and demonstration of trainee learning (p = 0.027) during the in vivo application of the ESSCAT suggest a high level of validity. Inter-rater reliability was moderate for competence decisions (Cohen's Kappa = 0.5) and good for total scores (Intra-Class Correlation Co-efficient = 0.63). Intra-rater reliability was good for both competence decisions (Kappa = 0.67) and total scores (Kendall's Tau-b = 0.73). The ESSCAT generates a valid and reliable assessment of trainees' in-theatre performance of endoscopic sinus surgery. In conjunction with ongoing evaluation of the instrument we recommend the use of the ESSCAT in higher specialist training in otolaryngology in the UK.

  17. Normalization of ADC does not improve correlation with overall survival in patients with high-grade glioma (HGG).

    PubMed

    Qin, Lei; Li, Angie; Qu, Jinrong; Reinshagen, Katherine; Li, Xiang; Cheng, Su-Chun; Bryant, Annie; Young, Geoffrey S

    2018-04-01

    Mixed reports leave uncertainty about whether normalization of apparent diffusion coefficient (ADC) to a within-subject white matter reference is necessary for assessment of tumor cellularity. We tested whether normalization improves the previously reported correlation of resection margin ADC with 15-month overall survival (OS) in HGG patients. Spin-echo echo-planar DWI was retrieved from 3 T MRI acquired between maximal resection and radiation in 37 adults with new-onset HGG (25 glioblastoma; 12 anaplastic astrocytoma). ADC maps were produced with the FSL DTIFIT tool (Oxford Centre for Functional MRI). 3 neuroradiologists manually selected regions of interest (ROI) in normal appearing white matter (NAWM) and in non-enhancing tumor (NT) < 2 cm from the margin of residual enhancing tumor or resection cavity. Normalized ADC (nADC) was computed as the ratio of absolute NT ADC to NAWM ADC. Reproducibility of nADC and absolute ADC among the readers' ROI was assessed using intra-class correlation coefficient (ICC) and within-subject coefficient of variation (wCV). Correlations of ADC and nADC with OS were compared using receiver operating characteristics (ROC) analysis. A p value 0.05 was considered statistically significant. Both mean ADC and nADC differed significantly between patients subgrouped by 15-month OS (p = 0.0014 and 0.0073 respectively). wCV and ICC among the readers were similar for absolute and normalized ADC. In ROC analysis of correlation with OS, nADC did not perform significantly better than absolute ADC. Normalization does not significantly improve the correlation of absolute ADC with OS in HGG, suggesting that normalization is not necessary for clinical or research ADC analysis in HGG patients.

  18. School and class-level variations and patterns of physical activity: a multilevel analysis of Danish high school students.

    PubMed

    Steenholt, Carina Bjørnskov; Pisinger, Veronica Sofie Clara; Danquah, Ida Høgstedt; Tolstrup, Janne Schurmann

    2018-02-14

    There is limited knowledge of physical activity (PA) patterns among high school students. High schools plays an important role as context for the students, but it is uncertain to what extent schools influence student participation in PA during leisure time. The purpose of this study is to describe patterns of PA and assess variations between schools and classes in PA, in a large cohort of Danish high school students. Self-reported cross-sectional data came from The Danish National Youth Study, comprising a total of 70,674 students attending 119 different schools and 3213 classes. Multilevel logistic regressions were applied to evaluate the association between socio-demographic variables and patterns of PA, and to assess the impact of schools and classes on PA measures. Students whose parents have achieved a lower level of education, older students and girls of perceived ethnic minority generally participated less in several forms of PA during leisure time. Substantial variations between schools were observed in terms of participation in PA at school during leisure time and in terms of use of active transportation to and from school. The school-level accounted for 9% (intra-class correlation coefficient (ICC) = 0.09 (95% CI: 0.06-0.11)) and 8% (ICC = 0.08 (95% CI: 0.07-0.11)) of the variation for participation in PA during leisure time and active transportation. Overall, students whose parents achieved a lower level of education, older students and girls of perceived ethnic minority represent vulnerable groups in relation to participation in several forms of PA during leisure time. The ICCs indicate that schools, in particular, have the potential to influence participation in PA at school during leisure time and active transportation to and from school. Thus, high schools should encourage and facilitate activities aimed at engaging students in PA during leisure time as well as encourage active transportation.

  19. Mammography image quality and evidence based practice: Analysis of the demonstration of the inframammary angle in the digital setting.

    PubMed

    Spuur, Kelly; Webb, Jodi; Poulos, Ann; Nielsen, Sharon; Robinson, Wayne

    2018-03-01

    The aim of this study is to determine the clinical rates of the demonstration of the inframammary angle (IMA) on the mediolateral oblique (MLO) view of the breast on digital mammograms and to compare the outcomes with current accreditation standards for compliance. Relationships between the IMA, age, the posterior nipple line (PNL) and compressed breast thickness will be identified and the study outcomes validated using appropriate analyses of inter-reader and inter-rater reliability and variability. Differences in left versus right data were also investigated. A quantitative retrospective study of 2270 randomly selected paired digital mammograms performed by BreastScreen NSW was undertaken. Data was collected by direct measurement and visual analysis. Intra-class correlation analyses were used to evaluate inter- and intra-rater reliability. The IMA was demonstrated on 52.4% of individual and 42.6% of paired mammograms. A linear relationship was found between the posterior nipple line (PNL) and age (p-value <0.001). The PNL was predicted to increase by 0.48 mm for every one year increment in age. The odds of demonstrating the IMA reduced by 2% for every one year increase in age (p-value = 0.001); are 0.4% higher for every 1 mm increase in PNL (p-value = 0.001) and 1.6% lower for every 1 mm increase in compressed breast thickness, (p-value<0.001). There was high inter- and intra-rater reliability for the PNL while there was 100% agreement for the demonstration of the IMA. Analysis of the demonstration of the IMA indicates clinically achievable rates (42.6%) well below that required for compliance (50%-75%) to known worldwide accreditation standards for screening mammography. These standards should be aligned to the reported evidence base. Visualisation of the IMA is impacted negatively by increasing age and compressed breast thickness but positively by breast size (PNL). Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Kinematic predictors of single-leg squat performance: a comparison of experienced physiotherapists and student physiotherapists.

    PubMed

    Weeks, Benjamin K; Carty, Christopher P; Horan, Sean A

    2012-10-25

    The single-leg squat (SLS) is a common test used by clinicians for the musculoskeletal assessment of the lower limb. The aim of the current study was to reveal the kinematic parameters used by experienced and inexperienced clinicians to determine SLS performance and establish reliability of such assessment. Twenty-two healthy, young adults (23.8 ± 3.1 years) performed three SLSs on each leg whilst being videoed. Three-dimensional data for the hip and knee was recorded using a 10-camera optical motion analysis system (Vicon, Oxford, UK). SLS performance was rated from video data using a 10-point ordinal scale by experienced musculoskeletal physiotherapists and student physiotherapists. All ratings were undertaken a second time at least two weeks after the first by the same raters. Stepwise multiple regression analysis was performed to determine kinematic predictors of SLS performance scores and inter- and intra-rater reliability were determined using a two-way mixed model to generate intra-class correlation coefficients (ICC3,1) of consistency. One SLS per leg for each participant was used for analysis, providing 44 SLSs in total. Eight experienced physiotherapists and eight physiotherapy students agreed to rate each SLS. Variance in physiotherapist scores was predicted by peak knee flexion, knee medio-lateral displacement, and peak hip adduction (R2 = 0.64, p = 0.01), while variance in student scores was predicted only by peak knee flexion, and knee medio-lateral displacement (R2 = 0.57, p = 0.01). Inter-rater reliability was good for physiotherapists (ICC3,1 = 0.71) and students (ICC3,1 = 0.60), whilst intra-rater reliability was excellent for physiotherapists (ICC3,1 = 0.81) and good for students (ICC3,1 = 0.71). Physiotherapists and students are both capable of reliable assessment of SLS performance. Physiotherapist assessments, however, bear stronger relationships to lower limb kinematics and are more sensitive to hip joint motion than student assessments.

  1. The dissolution kinetics of major elements in municipal solid waste incineration bottom ash particles

    NASA Astrophysics Data System (ADS)

    Bendz, David; Tüchsen, Peter L.; Christensen, Thomas H.

    2007-12-01

    Leaching and tracer experiments in batches at L/S 20 were performed with 3-month-old MSWI bottom ash separated into eight different particle sizes. The time-dependent leaching of major elements (Ca 2+, K +, Na +, Cl - and SO 4- 2 ) was monitored for up to 747 h. Physical properties of the particles, the specific surface (BET), pore volume and pore volume distribution over pore sizes (BJH) were determined for all particle classes by N 2 adsorption/desorption experiments. Some common features of physical pore structure for all particles were revealed. The specific surface and the particle pore volume were found to be negatively correlated with particle size, ranging from 3.2 m 2/g to 25.7 m 2/g for the surface area and from 0.0086 cm 3/g to 0.091 cm 3/g for the pore volume. Not surprisingly, the specific surface area was found to be the major material parameter that governed the leaching behavior for all elements (Ca 2+, K +, Na +, Cl - and SO 4- 2 ) and particle sizes. The diffusion resistance was determined independently by separate tracer (tritium) experiments. Diffusion gave a significant contribution to the apparent leaching kinetics for all elements during the first 10-40 h (depending on the particle size) of leaching and surface reaction was the overall rate controlling mechanism at late times for all particle sizes. For Ca 2+ and SO 4- 2 , the coupled effect of diffusion resistance and the degree of undersaturation in the intra particle pore volume was found to be a major rate limiting dissolution mechanism for both early and late times. The solubility control in the intra particulate porosity may undermine any attempt to treat bottom ash by washing out the sulfate. Even for high liquid/solid ratios, the solubility in the intra-particular porosity will limit the release rate.

  2. Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis.

    PubMed

    Izatt, Maree T; Bateman, Gary R; Adam, Clayton J

    2012-07-30

    Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions.

  3. Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis

    PubMed Central

    2012-01-01

    Background Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Methods Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Results Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. Conclusions The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions. PMID:22846346

  4. Reliability and Validity of a New Test of Change-of-Direction Speed for Field-Based Sports: the Change-of-Direction and Acceleration Test (CODAT).

    PubMed

    Lockie, Robert G; Schultz, Adrian B; Callaghan, Samuel J; Jeffriess, Matthew D; Berry, Simon P

    2013-01-01

    Field sport coaches must use reliable and valid tests to assess change-of-direction speed in their athletes. Few tests feature linear sprinting with acute change- of-direction maneuvers. The Change-of-Direction and Acceleration Test (CODAT) was designed to assess field sport change-of-direction speed, and includes a linear 5-meter (m) sprint, 45° and 90° cuts, 3- m sprints to the left and right, and a linear 10-m sprint. This study analyzed the reliability and validity of this test, through comparisons to 20-m sprint (0-5, 0-10, 0-20 m intervals) and Illinois agility run (IAR) performance. Eighteen Australian footballers (age = 23.83 ± 7.04 yrs; height = 1.79 ± 0.06 m; mass = 85.36 ± 13.21 kg) were recruited. Following familiarization, subjects completed the 20-m sprint, CODAT, and IAR in 2 sessions, 48 hours apart. Intra-class correlation coefficients (ICC) assessed relative reliability. Absolute reliability was analyzed through paired samples t-tests (p ≤ 0.05) determining between-session differences. Typical error (TE), coefficient of variation (CV), and differences between the TE and smallest worthwhile change (SWC), also assessed absolute reliability and test usefulness. For the validity analysis, Pearson's correlations (p ≤ 0.05) analyzed between-test relationships. Results showed no between-session differences for any test (p = 0.19-0.86). CODAT time averaged ~6 s, and the ICC and CV equaled 0.84 and 3.0%, respectively. The homogeneous sample of Australian footballers meant that the CODAT's TE (0.19 s) exceeded the usual 0.2 x standard deviation (SD) SWC (0.10 s). However, the CODAT is capable of detecting moderate performance changes (SWC calculated as 0.5 x SD = 0.25 s). There was a near perfect correlation between the CODAT and IAR (r = 0.92), and very large correlations with the 20-m sprint (r = 0.75-0.76), suggesting that the CODAT was a valid change-of-direction speed test. Due to movement specificity, the CODAT has value for field sport assessment. Key pointsThe change-of-direction and acceleration test (CODAT) was designed specifically for field sport athletes from specific speed research, and data derived from time-motion analyses of sports such as rugby union, soccer, and Australian football. The CODAT features a linear 5-meter (m) sprint, 45° and 90° cuts and 3-m sprints to the left and right, and a linear 10-m sprint.The CODAT was found to be a reliable change-of-direction speed assessment when considering intra-class correlations between two testing sessions, and the coefficient of variation between trials. A homogeneous sample of Australian footballers resulted in absolute reliability limitations when considering differences between the typical error and smallest worthwhile change. However, the CODAT will detect moderate (0.5 times the test's standard deviation) changes in performance.The CODAT correlated with the Illinois agility run, highlighting that it does assess change-of-direction speed. There were also significant relationships with short sprint performance (i.e. 0-5 m and 0-10 m), demonstrating that linear acceleration is assessed within the CODAT, without the extended duration and therefore metabolic limitations of the IAR. Indeed, the average duration of the test (~6 seconds) is field sport-specific. Therefore, the CODAT could be used as an assessment of change-of-direction speed in field sport athletes.

  5. Limited utility of tissue micro-arrays in detecting intra-tumoral heterogeneity in stem cell characteristics and tumor progression markers in breast cancer.

    PubMed

    Kündig, Pascale; Giesen, Charlotte; Jackson, Hartland; Bodenmiller, Bernd; Papassotirolopus, Bärbel; Freiberger, Sandra Nicole; Aquino, Catharine; Opitz, Lennart; Varga, Zsuzsanna

    2018-05-08

    Intra-tumoral heterogeneity has been recently addressed in different types of cancer, including breast cancer. A concept describing the origin of intra-tumoral heterogeneity is the cancer stem-cell hypothesis, proposing the existence of cancer stem cells that can self-renew limitlessly and therefore lead to tumor progression. Clonal evolution in accumulated single cell genomic alterations is a further possible explanation in carcinogenesis. In this study, we addressed the question whether intra-tumoral heterogeneity can be reliably detected in tissue-micro-arrays in breast cancer by comparing expression levels of conventional predictive/prognostic tumor markers, tumor progression markers and stem cell markers between central and peripheral tumor areas. We analyzed immunohistochemical expression and/or gene amplification status of conventional prognostic tumor markers (ER, PR, HER2, CK5/6), tumor progression markers (PTEN, PIK3CA, p53, Ki-67) and stem cell markers (mTOR, SOX2, SOX9, SOX10, SLUG, CD44, CD24, TWIST) in 372 tissue-micro-array samples from 72 breast cancer patients. Expression levels were compared between central and peripheral tumor tissue areas and were correlated to histopathological grading. 15 selected cases additionally underwent RNA sequencing for transcriptome analysis. No significant difference in any of the analyzed between central and peripheral tumor areas was seen with any of the analyzed methods/or results that showed difference. Except mTOR, PIK3CA and SOX9 (nuclear) protein expression, all markers correlated significantly (p < 0.05) with histopathological grading both in central and peripheral areas. Our results suggest that intra-tumoral heterogeneity of stem-cell and tumor-progression markers cannot be reliably addressed in tissue-micro-array samples in breast cancer. However, most markers correlated strongly with histopathological grading confirming prognostic information as expression profiles were independent on the site of the biopsy was taken.

  6. Bohler's angle's role in assessing the injury severity and functional outcome of internal fixation for displaced intra-articular calcaneal fractures: a retrospective study.

    PubMed

    Su, Yanling; Chen, Wei; Zhang, Tao; Wu, Xingwang; Wu, Zhanpo; Zhang, Yingze

    2013-09-24

    Controversy exits over the role of Böhler's angle in assessing the injury severity of displaced intra-articular calcaneal fractures and predicting the functional outcome following internal fixation. This study aims to investigate whether a correlation exists between Böhler's angle and the injury severity of displaced calcaneal fractures, and between surgical improvement of Böhler's angle and functional outcome. Patients treated operatively for unilateral closed displaced intra-articular calcaneal fractures from January 1, 2004 to March 31, 2008 were identified. The Böhler's angles of both calcaneus were measured, and the measurement of the uninjured foot was used as its normal control. The difference in the value of Böhler's angle measured preoperatively or postoperatively between the angle of the injured foot and that of the contralateral calcaneus were calculated, respectively. The change in Böhler's angle by ratio was calculated by dividing the difference value of Böhler's angle between bilateral calcaneus by its normal control. The injury severity was assessed according to Sanders classification. The functional outcomes were assessed using American Orthopaedic Foot & Ankle Society hindfoot scores. 274 patients were included into the study with a mean follow-up duration of 71 months. According to Sanders classification, the fracture pattern included 105 type II, 121 type III and 48 type IV fractures. According to American Orthopaedic Foot & Ankle Society hindfoot scoring system, the excellent, good, fair and poor results were achieved in 104, 132, 27, and 11 patients, respectively. The preoperative Böhler's angle, difference value of Böhler's angle between bilateral calcaneus, and change in Böhler's angle by ratio each has a significant correlation with Sanders classification (rs=-0.178, P=0.003; rs=-0.174, P=0.004; rs=-0.172, P=0.005, respectively), however, is not correlated with functional outcome individually. The three postoperative measurements were all found to have a significant correlation with American Orthopaedic Foot & Ankle Society hindfoot scores (rs=0.223, P<0.001; rs=0.224, P<0.001; rs=0.220, P<0.001, respectively). However, these correlations were all weak to low. There was a significant correlation between preoperative Böhler's angle and the injury severity of displaced intra-articular calcaneal fractures, but only postoperative Böhler's angle parameters were found to have a significant correlation with the functional recovery.

  7. A neoliberalisation of civil society? Self-help groups and the labouring class poor in rural South India.

    PubMed

    Pattenden, Jonathan

    2010-01-01

    This paper notes the prominence of self-help groups (SHGs) within current anti-poverty policy in India, and analyses the impacts of government- and NGO-backed SHGs in rural North Karnataka. It argues that self-help groups represent a partial neoliberalisation of civil society in that they address poverty through low-cost methods that do not challenge the existing distribution of power and resources between the dominant class and the labouring class poor. It finds that intra-group savings and loans and external loans/subsidies can provide marginal economic and political gains for members of the dominant class and those members of the labouring classes whose insecure employment patterns currently provide above poverty line consumption levels, but provide neither material nor political gains for the labouring class poor. Target-oriented SHG catalysts are inattentive to how the social relations of production reproduce poverty and tend to overlook class relations and socio-economic and political differentiation within and outside of groups, which are subject to interference by dominant class local politicians and landowners.

  8. High-frequency daily temperature variability in China and its relationship to large-scale circulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Fu-Ting; Fu, Congbin; Qian, Yun

    Two measures of intra-seasonal variability, indicated respectively by standard deviations (SD) and day-to-day (DTD) fluctuations denoted by absolute differences between adjacent 2-day periods, as well as their relationships with large-scale circulation patterns were investigated in China during 1962–2008 on the basis of homogenized daily temperature records from 549 local stations and reanalysis data. Our results show that both the SD and DTD of daily minimum temperatures (Tmin) in summer as well as the minimum and maximum temperatures in winter have been decreasing, while the daily maximum temperature (Tmax) variability in summer is fluctuating more, especially over southern China. In summer,more » an attribution analysis indicates that the intensity of the Western Pacific Subtropical High (WPSH) and high-level East Asian Subtropical Jet stream (EASJ) are positively correlated with both SD and DTD, but the correlation coefficients are generally greater with the SD than with the DTD of the daily maximum temperature, Tmax. In contrast, the location of the EASJ shows the opposite correlation pattern, with intensity regarding the correlation with both SD and DTD. In winter, the Arctic Oscillation (AO) is negatively correlated with both the SD and DTD of the daily minimum temperature, but its intra-seasonal variability exhibits good agreement with the SD of the Tmin. The Siberian High acts differently with respect to the SD and DTD of the Tmin, demonstrating a regionally consistent positive correlation with the SD. Overall, the large-scale circulation can well explain the intra-seasonal SD, but DTD fluctuations may be more local and impacted by local conditions, such as changes in the temperature itself, the land surface, and so on.« less

  9. Intra-hemispheric intrinsic connectivity asymmetry and its relationships with handedness and language Lateralization.

    PubMed

    Joliot, M; Tzourio-Mazoyer, N; Mazoyer, B

    2016-12-01

    Asymmetry in intra-hemispheric intrinsic connectivity, and its association with handedness and hemispheric dominance for language, were investigated in a sample of 290 healthy volunteers enriched in left-handers (52.7%). From the resting-state FMRI data of each participant, we derived an intra-hemispheric intrinsic connectivity asymmetry (HICA) matrix as the difference between the left and right intra-hemispheric matrices of intrinsic correlation computed for each pair of the AICHA atlas ROIs. We defined a similarity measure between the HICA matrices of two individuals as the correlation coefficient of their corresponding elements, and computed for each individual an index of intra-hemispheric intrinsic connectivity asymmetry as the average similarity measure of his HICA matrix to those of the other subjects of the sample (HICAs). Gaussian-mixture modeling of the age-corrected HICAs sample distribution revealed that two types of HICA patterns were present, one (Typical_HICA) including 92.4% of the participants while the other (Atypical_HICA) included only 7.6% of them, mostly left-handers. In addition, we investigated the relationship between asymmetry in intra-hemispheric intrinsic connectivity and language hemispheric dominance, including a potential effect of handedness on this relationship, thanks to an FMRI acquisition during language production from which an hemispheric functional lateralization index for language (HFLI) and a type of hemispheric dominance for language, namely leftward, ambilateral, or rightward, were derived for each individual. There was a significant association between the types of language hemispheric dominance and of intra-hemispheric intrinsic connectivity asymmetry, occurrence of Atypical_HICAs individuals being very high in the group of individuals rightward-lateralized for language (80%), reduced in the ambilateral group (19%) and rare in individuals leftward-lateralized for language (less than 3%). Quantitatively, we found a significant positive linear relationship between the HICAs and HFLI indices, with an effect of handedness on the intercept but not on the slope of this relationship. These findings demonstrate that handedness and hemispheric dominance for language are significantly but independently associated with the asymmetry of intra-hemispheric intrinsic connectivity. These findings suggest that asymmetry in intra-hemispheric connectivity is a variable phenotype shaped in part by hemispheric lateralization for language, but possibly also depending on other lateralized functions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Reversing the Speed-IQ Correlation: Intra-Individual Variability and Attentional Control in the Inspection Time Paradigm

    ERIC Educational Resources Information Center

    Fox, Mark C.; Roring, Roy W.; Mitchum, Ainsley L.

    2009-01-01

    Elementary cognitive tasks (ECTs) are simple tasks involving basic cognitive processes for which speed of performance typically correlates with IQ. Inspection time (IT) has the strongest IQ correlations and is considered critical evidence for neural speed underlying individual differences in intelligence. However, results from Bors et al. [Bors,…

  11. Test-retest reliability of pulse amplitude tonometry measures of vascular endothelial function: implications for clinical trial design.

    PubMed

    McCrea, Cindy E; Skulas-Ray, Ann C; Chow, Mosuk; West, Sheila G

    2012-02-01

    Endothelial dysfunction is an important outcome for assessing vascular health in intervention studies. However, reliability of the standard non-invasive method (flow-mediated dilation) is a significant challenge for clinical applications and multicenter trials. We evaluated the repeatability of pulse amplitude tonometry (PAT) to measure change in pulse wave amplitude during reactive hyperemia (Itamar Medical Ltd, Caesarea, Israel). Twenty healthy adults completed two PAT tests (mean interval = 19.5 days) under standardized conditions. PAT-derived measures of endothelial function (reactive hyperemia index, RHI) and arterial stiffness (augmentation index, AI) showed strong repeatability (intra-class correlations = 0.74 and 0.83, respectively). To guide future research, we also analyzed sample size requirements for a range of effect sizes. A crossover design powered at 0.90 requires 28 participants to detect a 15% change in RHI. Our study is the first to show that PAT measurements are repeatable in adults over an interval greater than 1 week.

  12. Aggressive Behavior between Siblings and the Development of Externalizing Problems: Evidence from a Genetically Sensitive Study

    PubMed Central

    Natsuaki, Misaki N.; Ge, Xiaojia; Reiss, David; Neiderhiser, Jenae M.

    2011-01-01

    This study investigated the prospective links between sibling aggression and the development of externalizing problems using a multilevel modeling approach with a genetically sensitive design. The sample consisted of 780 adolescents (390 sibling pairs) who participated in two waves of the Nonshared Environment for Adolescent Development (NEAD) project. Sibling pairs with varying degree of genetic relatedness, including monozygotic twins, dizygotic twins, full siblings, half siblings, and genetically unrelated siblings, were included. The results showed that sibling aggression at Time 1 was significantly associated with the focal child’s externalizing problems at Time 2 after accounting for the intra-class correlations between siblings. Sibling aggression remained significant in predicting subsequent externalizing problems even after controlling for the levels of pre-existing externalizing problems and mothers’ punitive parenting. This pattern of results was fairly robust across models using different informants. The findings provide converging evidence for the unique contribution of sibling aggression in understanding changes in externalizing problems during adolescence. PMID:19586176

  13. The Factor Structure of the Spiritual Well-Being Scale in Veterans Experienced Chemical Weapon Exposure.

    PubMed

    Sharif Nia, Hamid; Pahlevan Sharif, Saeed; Boyle, Christopher; Yaghoobzadeh, Ameneh; Tahmasbi, Bahram; Rassool, G Hussein; Taebei, Mozhgan; Soleimani, Mohammad Ali

    2018-04-01

    This study aimed to determine the factor structure of the spiritual well-being among a sample of the Iranian veterans. In this methodological research, 211 male veterans of Iran-Iraq warfare completed the Paloutzian and Ellison spiritual well-being scale. Maximum likelihood (ML) with oblique rotation was used to assess domain structure of the spiritual well-being. The construct validity of the scale was assessed using confirmatory factor analysis (CFA), convergent validity, and discriminant validity. Reliability was evaluated with Cronbach's alpha, Theta (θ), and McDonald Omega (Ω) coefficients, intra-class correlation coefficient (ICC), and construct reliability (CR). Results of ML and CFA suggested three factors which were labeled "relationship with God," "belief in fate and destiny," and "life optimism." The ICC, coefficients of the internal consistency, and CR were >.7 for the factors of the scale. Convergent validity and discriminant validity did not fulfill the requirements. The Persian version of spiritual well-being scale demonstrated suitable validity and reliability among the veterans of Iran-Iraq warfare.

  14. A two-factor theory for concussion assessment using ImPACT: memory and speed.

    PubMed

    Schatz, Philip; Maerlender, Arthur

    2013-12-01

    We present the initial validation of a two-factor structure of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) using ImPACT composite scores and document the reliability and validity of this factor structure. Factor analyses were conducted for baseline (N = 21,537) and post-concussion (N = 560) data, yielding "Memory" (Verbal and Visual) and "Speed" (Visual Motor Speed and Reaction Time) Factors; inclusion of Total Symptom Scores resulted in a third discrete factor. Speed and Memory z-scores were calculated, and test-retest reliability (using intra-class correlation coefficients) at 1 month (0.88/0.81), 1 year (0.85/0.75), and 2 years (0.76/0.74) were higher than published data using Composite scores. Speed and Memory scores yielded 89% sensitivity and 70% specificity, which was higher than composites (80%/62%) and comparable with subscales (91%/69%). This emergent two-factor structure has improved test-retest reliability with no loss of sensitivity/specificity and may improve understanding and interpretability of ImPACT test results.

  15. Gender classification in low-resolution surveillance video: in-depth comparison of random forests and SVMs

    NASA Astrophysics Data System (ADS)

    Geelen, Christopher D.; Wijnhoven, Rob G. J.; Dubbelman, Gijs; de With, Peter H. N.

    2015-03-01

    This research considers gender classification in surveillance environments, typically involving low-resolution images and a large amount of viewpoint variations and occlusions. Gender classification is inherently difficult due to the large intra-class variation and interclass correlation. We have developed a gender classification system, which is successfully evaluated on two novel datasets, which realistically consider the above conditions, typical for surveillance. The system reaches a mean accuracy of up to 90% and approaches our human baseline of 92.6%, proving a high-quality gender classification system. We also present an in-depth discussion of the fundamental differences between SVM and RF classifiers. We conclude that balancing the degree of randomization in any classifier is required for the highest classification accuracy. For our problem, an RF-SVM hybrid classifier exploiting the combination of HSV and LBP features results in the highest classification accuracy of 89.9 0.2%, while classification computation time is negligible compared to the detection time of pedestrians.

  16. Algorithm guided outlining of 105 pancreatic cancer liver metastases in Ultrasound.

    PubMed

    Hann, Alexander; Bettac, Lucas; Haenle, Mark M; Graeter, Tilmann; Berger, Andreas W; Dreyhaupt, Jens; Schmalstieg, Dieter; Zoller, Wolfram G; Egger, Jan

    2017-10-06

    Manual segmentation of hepatic metastases in ultrasound images acquired from patients suffering from pancreatic cancer is common practice. Semiautomatic measurements promising assistance in this process are often assessed using a small number of lesions performed by examiners who already know the algorithm. In this work, we present the application of an algorithm for the segmentation of liver metastases due to pancreatic cancer using a set of 105 different images of metastases. The algorithm and the two examiners had never assessed the images before. The examiners first performed a manual segmentation and, after five weeks, a semiautomatic segmentation using the algorithm. They were satisfied in up to 90% of the cases with the semiautomatic segmentation results. Using the algorithm was significantly faster and resulted in a median Dice similarity score of over 80%. Estimation of the inter-operator variability by using the intra class correlation coefficient was good with 0.8. In conclusion, the algorithm facilitates fast and accurate segmentation of liver metastases, comparable to the current gold standard of manual segmentation.

  17. Validation of equations for pleural effusion volume estimation by ultrasonography.

    PubMed

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  18. Carotid stenosis assessment with multi-detector CT angiography: comparison between manual and automatic segmentation methods.

    PubMed

    Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H

    2013-04-01

    Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.

  19. Recent developments in antibiotic agents for the treatment of complicated intra-abdominal infections.

    PubMed

    Lin, Shang-Yi; Huang, Chung-Hao; Ko, Wen-Chien; Chen, Yen-Hsu; Hsueh, Po-Ren

    2016-01-01

    Treatment of complicated intra-abdominal infections (cIAIs) is becoming increasingly difficult because of the widespread emergence of multidrug-resistant organisms. In this review, we discuss the effectiveness of several new antibiotics for the treatment of cIAIs, including new β-lactamase inhibitor combinations (BLICs) and tetracycline-class drugs, recently developed aminoglycosides and quinolones, and novel lipoglycopeptides and oxazolidinones. Of the new BLICs, ceftolozane/tazobactam is associated with adequate clinical cure rates in patients with cIAIs. Currently, two new β-lactamase inhibitors, namely avibactam and MK-7655, are under development for clinical use in the treatment of cIAIs. Eravacycline, a novel, fully synthetic tetracycline-class drug, has been shown in Phase II and III clinical trials to be more potent than tigecycline against a significant number of multidrug-resistant organisms causing cIAIs. Plazomicin, a next-generation aminoglycoside, is a promising agent for treatment of cIAIs due to multidrug-resistant pathogens. Of the recently developed quinolones, delafloxacin and finafloxacin have been shown to be effective against pathogens that survive and multiply in mildly acidic environments, although further clinical studies examining their clinical utility in the treatment of cIAIs are warranted. Oritavancin, a new semisynthetic lipoglycopeptide agent, has been demonstrated to be a potent antibiotic in the treatment of cIAIs due to drug-resistant Gram-positive organisms. Several other new antibiotics in development also show promise and will hopefully broaden the possibilities for treatment of complicated intra-abdominal infections due to MDR pathogens.

  20. Race, Gender and Class: Lyrics of American Ethnic Literature and Cultures.

    ERIC Educational Resources Information Center

    Wang, Qun

    2000-01-01

    Examines topical issues in the study of African American, Asian American, Native American, and Hispanic American cultures. Horizontally, the article discusses inter- and intra-cultural conflicts, use of two-toned language, and the fight for social justification as portrayed in American ethnic literatures. Vertically, the connection of these ethnic…

  1. Classroom Experiments: Teaching Specific Topics or Promoting the Economic Way of Thinking?

    ERIC Educational Resources Information Center

    Emerson, Tisha L. N.; English, Linda K.

    2016-01-01

    The authors' data contain inter- and intra-class variations in experiments to which students in a principles of microeconomics course were exposed. These variations allowed the estimation of the effect on student achievement from the experimental treatment generally, as well as effects associated with participation in specific experiments. The…

  2. Values and Self Esteem in Three Generations of Men and Women.

    ERIC Educational Resources Information Center

    Antonucci, Toni; And Others

    Intergenerational differences within the family were examined through an exploration of values in three-generation intra-family triads. Subjects (N=180) were 30 male and 30 female white middle class triads. Each triad consisted of a son, father, paternal grandfather or daughter, mother, maternal grandmother. Generation ranges were: youngest, 17-23…

  3. Spatial Patterns of Irradiance and Advanced Reproduction along a Canopy Disturbance Severity Gradient in an Upland Hardwood Stand

    Treesearch

    Amanda Keasberry; Justin Hart; Daniel C. Dey; Callie Schweitzer

    2016-01-01

    Regeneration failure of Quercus in mature Quercus-dominated forests has been reported throughout the temperate zone. Quercus seedlings are often abundant in these forests, yet frequently fail to recruit to larger size classes despite canopy disturbances. To examine intra-stand patterns of advanced...

  4. Poly-Cross-Linked PEI Through Aromatically Conjugated Imine Linkages as a New Class of pH-Responsive Nucleic Acids Packing Cationic Polymers

    PubMed Central

    Chen, Shun; Jin, Tuo

    2016-01-01

    Cationic polyimines polymerized through aromatically conjugated bis-imine linkages and intra-molecular cross-linking were found to be a new class of effective transfection materials for their flexibility in structural optimization, responsiveness to intracellular environment, the ability to facilitate endosome escape and cytosol release of the nucleic acids, as well as self-metabolism. When three phthalaldehydes of different substitution positions were used to polymerize highly branched low-molecular weight polyethylenimine (PEI 1.8K), the product through ortho-phthalimines (named PPOP) showed significantly higher transfection activity than its two tere- and iso-analogs (named PPTP and PPIP). Physicochemical characterization confirmed the similarity of three polyimines in pH-responded degradability, buffer capacity, as well as the size and Zeta potential of the polyplexes formed from the polymers. A mechanistic speculation may be that the ortho-positioned bis-imine linkage of PPOP may only lead to the straight trans-configuration due to steric hindrance, resulting in larger loops of intra-polymer cross-linking and more flexible backbone. PMID:26869931

  5. Variability of carotid artery measurements on 3-Tesla MRI and its impact on sample size calculation for clinical research.

    PubMed

    Syed, Mushabbar A; Oshinski, John N; Kitchen, Charles; Ali, Arshad; Charnigo, Richard J; Quyyumi, Arshed A

    2009-08-01

    Carotid MRI measurements are increasingly being employed in research studies for atherosclerosis imaging. The majority of carotid imaging studies use 1.5 T MRI. Our objective was to investigate intra-observer and inter-observer variability in carotid measurements using high resolution 3 T MRI. We performed 3 T carotid MRI on 10 patients (age 56 +/- 8 years, 7 male) with atherosclerosis risk factors and ultrasound intima-media thickness > or =0.6 mm. A total of 20 transverse images of both right and left carotid arteries were acquired using T2 weighted black-blood sequence. The lumen and outer wall of the common carotid and internal carotid arteries were manually traced; vessel wall area, vessel wall volume, and average wall thickness measurements were then assessed for intra-observer and inter-observer variability. Pearson and intraclass correlations were used in these assessments, along with Bland-Altman plots. For inter-observer variability, Pearson correlations ranged from 0.936 to 0.996 and intraclass correlations from 0.927 to 0.991. For intra-observer variability, Pearson correlations ranged from 0.934 to 0.954 and intraclass correlations from 0.831 to 0.948. Calculations showed that inter-observer variability and other sources of error would inflate sample size requirements for a clinical trial by no more than 7.9%, indicating that 3 T MRI is nearly optimal in this respect. In patients with subclinical atherosclerosis, 3 T carotid MRI measurements are highly reproducible and have important implications for clinical trial design.

  6. Large-Scale Phase Synchrony Reflects Clinical Status After Stroke: An EEG Study.

    PubMed

    Kawano, Teiji; Hattori, Noriaki; Uno, Yutaka; Kitajo, Keiichi; Hatakenaka, Megumi; Yagura, Hajime; Fujimoto, Hiroaki; Yoshioka, Tomomi; Nagasako, Michiko; Otomune, Hironori; Miyai, Ichiro

    2017-06-01

    Stroke-induced focal brain lesions often exert remote effects via residual neural network activity. Electroencephalographic (EEG) techniques can assess neural network modifications after brain damage. Recently, EEG phase synchrony analyses have shown associations between the level of large-scale phase synchrony of brain activity and clinical symptoms; however, few reports have assessed such associations in stroke patients. The aim of this study was to investigate the clinical relevance of hemispheric phase synchrony in stroke patients by calculating its correlation with clinical status. This cross-sectional study included 19 patients with post-acute ischemic stroke admitted for inpatient rehabilitation. Interhemispheric phase synchrony indices (IH-PSIs) were computed in 2 frequency bands (alpha [α], and beta [β]), and associations between indices and scores of the Functional Independence Measure (FIM), the National Institutes of Health Stroke Scale (NIHSS), and the Fugl-Meyer Motor Assessment (FMA) were analyzed. For further assessments of IH-PSIs, ipsilesional intrahemispheric PSIs (IntraH-PSIs) as well as IH- and IntraH-phase lag indices (PLIs) were also evaluated. IH-PSIs correlated significantly with FIM scores and NIHSS scores. In contrast, IH-PSIs did not correlate with FMA scores. IntraH-PSIs correlate with FIM scores after removal of the outlier. The results of analysis with PLIs were consistent with IH-PSIs. The PSIs correlated with performance on the activities of daily living scale but not with scores on a pure motor impairment scale. These results suggest that large-scale phase synchrony represented by IH-PSIs provides a novel surrogate marker for clinical status after stroke.

  7. Validity of the Special Needs Education Assessment Tool (SNEAT), a Newly Developed Scale for Children with Disabilities.

    PubMed

    Kohara, Aiko; Han, ChangWan; Kwon, HaeJin; Kohzuki, Masahiro

    2015-11-01

    The improvement of the quality of life (QOL) of children with disabilities has been considered important. Therefore, the Special Needs Education Assessment Tool (SNEAT) was developed based on the concept of QOL to objectively evaluate the educational outcome of children with disabilities. SNEAT consists of 11 items in three domains: physical functioning, mental health, and social functioning. This study aimed to verify the reliability and construct validity of SNEAT using 93 children collected from the classes on independent activities of daily living for children with disabilities in Okinawa Prefecture between October and November 2014. Survey data were collected in a longitudinal prospective cohort study. The reliability of SNEAT was verified via the internal consistency method and the test-pretest method; both the coefficient of Cronbach's α and the intra-class correlation coefficient were over 0.7. The validity of SNEAT was also verified via one-way repeated-measures ANOVA and the latent growth curve model. The scores of all the items and domains and the total scores obtained from one-way repeated-measures ANOVA were the same as the predicted scores. SNEAT is valid based on its goodness-of-fit values obtained using the latent growth curve model, where the values of comparative fit index (0.983) and root mean square error of approximation (0.062) were within the goodness-of-fit range. These results indicate that SNEAT has high reliability and construct validity and may contribute to improve QOL of children with disabilities in the classes on independent activities of daily living for children with disabilities.

  8. Cambial activity related to tree size in a mature silver-fir plantation.

    PubMed

    Rathgeber, Cyrille B K; Rossi, Sergio; Bontemps, Jean-Daniel

    2011-09-01

    Our knowledge about the influences of environmental factors on tree growth is principally based on the study of dominant trees. However, tree social status may influence intra-annual dynamics of growth, leading to differential responses to environmental conditions. The aim was to determine whether within-stand differences in stem diameters of trees belonging to different crown classes resulted from variations in the length of the growing period or in the rate of cell production. Cambial activity was monitored weekly in 2006 for three crown classes in a 40-year-old silver-fir (Abies alba) plantation near Nancy (France). Timings, duration and rate of tracheid production were assessed from anatomical observations of the developing xylem. Cambial activity started earlier, stopped later and lasted longer in dominant trees than in intermediate and suppressed ones. The onset of cambial activity was estimated to have taken 3 weeks to spread to 90 % of the trees in the stand, while the cessation needed 6 weeks. Cambial activity was more intense in dominant trees than in intermediate and suppressed ones. It was estimated that about 75 % of tree-ring width variability was attributable to the rate of cell production and only 25 % to its duration. Moreover, growth duration was correlated to tree height, while growth rate was better correlated to crown area. These results show that, in a closed conifer forest, stem diameter variations resulted principally from differences in the rate of xylem cell production rather than in its duration. Tree size interacts with environmental factors to control the timings, duration and rate of cambial activity through functional processes involving source-sink relationships principally, but also hormonal controls.

  9. The Health Informatics Trial Enhancement Project (HITE): Using routinely collected primary care data to identify potential participants for a depression trial

    PubMed Central

    2010-01-01

    Background Recruitment to clinical trials can be challenging. We identified anonymous potential participants to an existing pragmatic randomised controlled depression trial to assess the feasibility of using routinely collected data to identify potential trial participants. We discuss the strengths and limitations of this approach, assess its potential value, report challenges and ethical issues encountered. Methods Swansea University's Health Information Research Unit's Secure Anonymised Information Linkage (SAIL) database of routinely collected health records was interrogated, using Structured Query Language (SQL). Read codes were used to create an algorithm of inclusion/exclusion criteria with which to identify suitable anonymous participants. Two independent clinicians rated the eligibility of the potential participants' identified. Inter-rater reliability was assessed using the kappa statistic and inter-class correlation. Results The study population (N = 37263) comprised all adults registered at five general practices in Swansea UK. Using the algorithm 867 anonymous potential participants were identified. The sensitivity and specificity results > 0.9 suggested a high degree of accuracy from the algorithm. The inter-rater reliability results indicated strong agreement between the confirming raters. The Intra Class Correlation Coefficient (Cronbach's Alpha) > 0.9, suggested excellent agreement and Kappa coefficient > 0.8; almost perfect agreement. Conclusions This proof of concept study showed that routinely collected primary care data can be used to identify potential participants for a pragmatic randomised controlled trial of folate augmentation of antidepressant therapy for the treatment of depression. Further work will be needed to assess generalisability to other conditions and settings and the inclusion of this approach to support Electronic Enhanced Recruitment (EER). PMID:20398303

  10. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in postmenopausal women.

    PubMed

    Bea, J W; Blew, R M; Going, S B; Hsu, C-H; Lee, M C; Lee, V R; Caan, B J; Kwan, M L; Lohman, T G

    2016-11-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n = 103). ROIs were (1) lumbar vertebrae L2-L4 and (2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and (3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N = 25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Mean age, BMI, and total body fat were 66.1 ± 4.8 y, 25.8 ± 3.8 kg/m 2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R 2 : 0.83) and L2-IC (Adj. R 2 : 0.84) abdominal fat (%) well; the adjusted R 2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R 2 : 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat, respectively). The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in postmenopausal chronic disease risk prediction models. Am. J. Hum. Biol. 28:918-926, 2016. © 2016Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. A consistency evaluation of signal-to-noise ratio in the quality assessment of human brain magnetic resonance images.

    PubMed

    Yu, Shaode; Dai, Guangzhe; Wang, Zhaoyang; Li, Leida; Wei, Xinhua; Xie, Yaoqin

    2018-05-16

    Quality assessment of medical images is highly related to the quality assurance, image interpretation and decision making. As to magnetic resonance (MR) images, signal-to-noise ratio (SNR) is routinely used as a quality indicator, while little knowledge is known of its consistency regarding different observers. In total, 192, 88, 76 and 55 brain images are acquired using T 2 * , T 1 , T 2 and contrast-enhanced T 1 (T 1 C) weighted MR imaging sequences, respectively. To each imaging protocol, the consistency of SNR measurement is verified between and within two observers, and white matter (WM) and cerebral spinal fluid (CSF) are alternately used as the tissue region of interest (TOI) for SNR measurement. The procedure is repeated on another day within 30 days. At first, overlapped voxels in TOIs are quantified with Dice index. Then, test-retest reliability is assessed in terms of intra-class correlation coefficient (ICC). After that, four models (BIQI, BLIINDS-II, BRISQUE and NIQE) primarily used for the quality assessment of natural images are borrowed to predict the quality of MR images. And in the end, the correlation between SNR values and predicted results is analyzed. To the same TOI in each MR imaging sequence, less than 6% voxels are overlapped between manual delineations. In the quality estimation of MR images, statistical analysis indicates no significant difference between observers (Wilcoxon rank sum test, p w  ≥ 0.11; paired-sample t test, p p  ≥ 0.26), and good to very good intra- and inter-observer reliability are found (ICC, p icc  ≥ 0.74). Furthermore, Pearson correlation coefficient (r p ) suggests that SNR wm correlates strongly with BIQI, BLIINDS-II and BRISQUE in T 2 * (r p  ≥ 0.78), BRISQUE and NIQE in T 1 (r p  ≥ 0.77), BLIINDS-II in T 2 (r p  ≥ 0.68) and BRISQUE and NIQE in T 1 C (r p  ≥ 0.62) weighted MR images, while SNR csf correlates strongly with BLIINDS-II in T 2 * (r p  ≥ 0.63) and in T 2 (r p  ≥ 0.64) weighted MR images. The consistency of SNR measurement is validated regarding various observers and MR imaging protocols. When SNR measurement performs as the quality indicator of MR images, BRISQUE and BLIINDS-II can be conditionally used for the automated quality estimation of human brain MR images.

  12. Toward a Computer Vision-based Wayfinding Aid for Blind Persons to Access Unfamiliar Indoor Environments.

    PubMed

    Tian, Yingli; Yang, Xiaodong; Yi, Chucai; Arditi, Aries

    2013-04-01

    Independent travel is a well known challenge for blind and visually impaired persons. In this paper, we propose a proof-of-concept computer vision-based wayfinding aid for blind people to independently access unfamiliar indoor environments. In order to find different rooms (e.g. an office, a lab, or a bathroom) and other building amenities (e.g. an exit or an elevator), we incorporate object detection with text recognition. First we develop a robust and efficient algorithm to detect doors, elevators, and cabinets based on their general geometric shape, by combining edges and corners. The algorithm is general enough to handle large intra-class variations of objects with different appearances among different indoor environments, as well as small inter-class differences between different objects such as doors and door-like cabinets. Next, in order to distinguish intra-class objects (e.g. an office door from a bathroom door), we extract and recognize text information associated with the detected objects. For text recognition, we first extract text regions from signs with multiple colors and possibly complex backgrounds, and then apply character localization and topological analysis to filter out background interference. The extracted text is recognized using off-the-shelf optical character recognition (OCR) software products. The object type, orientation, location, and text information are presented to the blind traveler as speech.

  13. Toward a Computer Vision-based Wayfinding Aid for Blind Persons to Access Unfamiliar Indoor Environments

    PubMed Central

    Tian, YingLi; Yang, Xiaodong; Yi, Chucai; Arditi, Aries

    2012-01-01

    Independent travel is a well known challenge for blind and visually impaired persons. In this paper, we propose a proof-of-concept computer vision-based wayfinding aid for blind people to independently access unfamiliar indoor environments. In order to find different rooms (e.g. an office, a lab, or a bathroom) and other building amenities (e.g. an exit or an elevator), we incorporate object detection with text recognition. First we develop a robust and efficient algorithm to detect doors, elevators, and cabinets based on their general geometric shape, by combining edges and corners. The algorithm is general enough to handle large intra-class variations of objects with different appearances among different indoor environments, as well as small inter-class differences between different objects such as doors and door-like cabinets. Next, in order to distinguish intra-class objects (e.g. an office door from a bathroom door), we extract and recognize text information associated with the detected objects. For text recognition, we first extract text regions from signs with multiple colors and possibly complex backgrounds, and then apply character localization and topological analysis to filter out background interference. The extracted text is recognized using off-the-shelf optical character recognition (OCR) software products. The object type, orientation, location, and text information are presented to the blind traveler as speech. PMID:23630409

  14. The effect of flash-freezing temperature on stallion sperm DNA structure.

    PubMed

    Serafini, R; Varner, D D; Bissett, W; Blanchard, T L; Teague, S R; Love, C C

    2017-06-01

    The effect of flash-freezing storage temperature on stallion sperm DNA has not been evaluated. Commonly, sperm are flash-frozen at various temperatures to preserve sperm DNA prior to analysis. It is unclear whether the temperature at which sperm are frozen and stored may affect the results of DNA assays. In this study, the neutral comet assay was used to evaluate the effect of flash-freezing storage temperature (freezer [-60 °C], dry ice [-78.5 °C], liquid nitrogen [-196 °C]) compared to fresh sperm DNA structure. In addition, intra- and inter-assay and intra- and inter-stallion variabilities were determined. All comet tail measures were higher following any flash-freezing method, as compared to fresh sperm DNA (P < 0.05), with no difference among flash-frozen treatments (P > 0.05). For most comet variables, intra- and inter-assay variabilities were <10%. Intra- and inter-stallion variabilities revealed that comet head length (HL) and width (CW) were less variable as compared to comet tail values, i.e., % comet tail DNA (T-DNA), tail length (TL), tail moment (OTM), and tail migration (TM). Certain comet tail values in fresh (% T-DNA, and OTM) and flash-frozen sperm (OTM, % T-DNA, TL, and TM) were correlated to the Sperm Chromatin Structure Assay (SCSA) variable, COMP-α t . The comet tail measures were negatively correlated to % morphologically normal sperm (P < 0.05) and positively correlated to % abnormal heads and premature germ cells (P < 0.05). Variables COMP-α t and % total sperm motility were not correlated to any morphologic sperm feature in this group of stallions (P > 0.05). While significant differences in the structure of the sperm DNA were identified in the flash-frozen as compared to the fresh sperm DNA with the neutral comet assay, it cannot be assumed that these changes are fertility limiting. Copyright © 2017. Published by Elsevier Inc.

  15. Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

    PubMed

    Akima, Hiroshi; Hioki, Maya; Yoshiko, Akito; Koike, Teruhiko; Sakakibara, Hisataka; Takahashi, Hideyuki; Oshida, Yoshiharu

    2016-05-01

    The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonography of human skeletal muscles. Thirty young and elderly men and women were included. T1-weighted MRI was taken from the right mid-thigh to measure IntraMAT content of the vastus lateralis (VL) and biceps femoris (BF) using a histogram shape-based thresholding technique. IMCL and EMCL were measured from the VL and BF at the right mid-thigh using (1)H MRS. Ultrasonographic images were taken from the VL and BF of the right mid-thigh to measure echo intensity based on gray-scale level for quantitative analysis. There was a significant correlation between IntraMAT content by MRI and EMCL of the VL and BF (VL, r=0.506, P<0.01; BF, r=0.591, P<0.001) and between echo intensity and EMCL of the VL and BF (VL, r=0.485, P<0.05; BF, r=0.648, P<0.01). IntraMAT content was also significantly correlated with echo intensity of the VL and BF (VL, r=0.404, P<0.05; BF, r=0.493, P<0.01). Our study suggests that IntraMAT content determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids, not intramyocellular lipids, in human skeletal muscles. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Growth hormone in intra-uterine growth retarded newborns.

    PubMed

    Setia, Sajita; Sridhar, M G; Bhat, Vishnu; Chaturvedula, Latha

    2007-11-01

    To study growth hormone levels in IUGR and healthy controls and its association with birth weight and ponderal index. We studied 50 Intra uterine growth retarded (IUGR) and 50 healthy newborns born at term by vaginal delivery in JIPMER, Pondicherry, India. Cord blood was collected at the time of delivery for measurement of growth hormone. When compared with healthy newborns, IUGR newborns had higher growth hormone levels (mean +/- SD, 23.5 +/- 15.6 vs 16.2 +/- 7.61 ngm/ml, P = 0.019). A negative correlation was identified between growth hormone levels and birth weight (r2 = - 0.22, P = 0.03) and ponderal index (r2 = - 0.36, P = 0.008). Correlation of growth hormone levels was much more confident with ponderal index than with birth weight. At birth IUGR infants display increased growth hormone levels which correlate with ponderal index much more confidently than with birth weight.

  17. On the implications of the classical ergodic theorems: analysis of developmental processes has to focus on intra-individual variation.

    PubMed

    Molenaar, Peter C M

    2008-01-01

    It is argued that general mathematical-statistical theorems imply that standard statistical analysis techniques of inter-individual variation are invalid to investigate developmental processes. Developmental processes have to be analyzed at the level of individual subjects, using time series data characterizing the patterns of intra-individual variation. It is shown that standard statistical techniques based on the analysis of inter-individual variation appear to be insensitive to the presence of arbitrary large degrees of inter-individual heterogeneity in the population. An important class of nonlinear epigenetic models of neural growth is described which can explain the occurrence of such heterogeneity in brain structures and behavior. Links with models of developmental instability are discussed. A simulation study based on a chaotic growth model illustrates the invalidity of standard analysis of inter-individual variation, whereas time series analysis of intra-individual variation is able to recover the true state of affairs. (c) 2007 Wiley Periodicals, Inc.

  18. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    PubMed Central

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024

  19. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    PubMed

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  20. Africa's middle class women bring entrepreneurial opportunities in breast care medical tourism to South Africa.

    PubMed

    Ahwireng-Obeng, Frederick; van Loggerenberg, Charl

    2011-01-01

    Africa's distribution of specialized private health services is severely disproportionate. Mismatch between South Africa's excess supply and a huge demand potential in an under-serviced continent represents an entrepreneurial opportunity to attract patients to South Africa for treatment and recuperative holidays. However, effective demand for intra-African medical tourism could be constrained by sub-Saharan poverty. Results from interviewing 320 patients and five staff at the Johannesburg Breast care Centre of Excellence, however, reject this proposition, Africa's middle class women being the target market estimated to grow annually by one million while breast cancer incidence increases with middle-class lifestyles. Uncovering this potential involves an extensive marketing strategy. Copyright © 2010 John Wiley & Sons, Ltd.

  1. Latent classes of sexual behaviors: Prevalence, predictors, and consequences

    PubMed Central

    Wesche, Rose; Lefkowitz, Eva S.; Vasilenko, Sara A.

    2016-01-01

    Scholars of adolescent and emerging adult sexuality have recently begun to study how diverse patterns of sexual behaviors contribute to development and well-being. A person-oriented approach to studying sexual behaviors provides a nuanced understanding of sexual repertoires. The goals of this paper were to document patterns of sexual behaviors ranging from kissing to penetrative sex, and to examine how latent classes of behaviors, gender, and partner type (romantic vs. nonromantic) predict intra- and interpersonal consequences of sexual behaviors. Latent class analysis of a stratified random sample of U.S. college students revealed four classes of sexual behaviors: Kissing Only, Kissing and Touching, All Behaviors, and Oral and Penetrative Only. Compared to individuals in the All Behaviors class, individuals in the Kissing Only class were less likely to experience a positive or a negative intrapersonal consequence of sexual behaviors. Men were less likely to report a negative intrapersonal consequence than women were. Partner type predicted negative interpersonal consequences for the All Behaviors class. Implications are discussed in terms of normative sexual development, prevention, and sexual and relationship education. PMID:28163800

  2. Practice of preventive dentistry for nursing staff in primary care.

    PubMed

    Jiménez-Báez, María Valeria; Acuña-Reyes, Raquel; Cigarroa-Martínez, Didier; Ureña-Bogarín, Enrique; Orgaz-Fernández, Jose David

    2014-01-01

    Determine the domain of preventive dentistry in nursing personnel assigned to a primary care unit. Prospective descriptive study, questionnaire validation, and prevalence study. In the first stage, the questionnaire for the practice of preventive dentistry (CPEP, for the term in Spanish) was validated; consistency and reliability were measured by Cronbach's alpha, Pearson's correlation, factor analysis with intra-class correlation coefficient (ICC). In the second stage, the domain in preventive dental nurses was explored. The overall internal consistency of CPEP is α= 0.66, ICC= 0.64, CI95%: 0.29-0.87 (p >0.01). Twenty-one subjects in the study, average age 43, 81.0% female, average seniority of 12.5 were included. A total of 71.5% showed weak domain, 28.5% regular domain, and there was no questionnaire with good domain result. The older the subjects were, the smaller the domain; female nurses showed greater mastery of preventive dentistry (29%, CI95%: 0.1-15.1) than male nurses. Public health nurses showed greater mastery with respect to other categories (50%, CI95%: 0.56-2.8). The CDEP has enough consistency to explore the domain of preventive dentistry in health-care staff. The domain of preventive dentistry in primary care nursing is poor, required to strengthen to provide education in preventive dentistry to the insured population.

  3. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    PubMed

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; p<0.05). The questionnaire had also been demonstrated to have a good validity with a proven high correlation to each question of SF-36 (p<0.05). the Indonesian version of GERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  4. Health related quality of life in disorders of defecation: the Defecation Disorder List

    PubMed Central

    Voskuijl, W; van der Zaag-Loon..., H J; Ketel, I; Grootenhuis, M; Derkx, B; Benninga, M

    2004-01-01

    Background: Constipation and encopresis frequently cause problems with respect to emotional wellbeing, and social and family life. Instruments to measure Health Related Quality of Life (HRQoL) in these disorders are not available. Methods: A disease specific HRQoL instrument, the "Defecation Disorder List" (DDL) for children with constipation or functional non-retentive faecal soiling (FNRFS) was developed using accepted guidelines. For each phase of the process, different samples of patients were used. The final phase of development included 27 children. Reliability was assessed in two ways: internal consistency of domains with Cronbach's alpha, and test-retest reliability with intra-class correlation coefficients (ICC). To assess validity, comparable items and domains were correlated with Tacqol, a generic HRQoL instrument for children (TNO-AZL). Results: In the final phase of the development, 27 children completed the instrument. It consisted of 37 items in four domains. The response rate was 96%. Reliability was good for all domains, with Cronbach's alpha values ranging from 0.61 to 0.76. Measures of test-retest stability were good for all four domains with ICCs ranging from 0.82 to 0.92. Validity based on comparison with the Tacqol instrument was moderate. Conclusion: The DDL is promising as a measure of HRQoL in childhood defecation disorders. PMID:15557046

  5. Predicting the nodal status in gastric cancers: The role of apparent diffusion coefficient histogram characteristic analysis.

    PubMed

    Liu, Song; Zhang, Yujuan; Xia, Jie; Chen, Ling; Guan, Wenxian; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang

    2017-10-01

    To explore the application of histogram analysis in preoperative T and N staging of gastric cancers, with a focus on characteristic parameters of apparent diffusion coefficient (ADC) maps. Eighty-seven patients with gastric cancers underwent diffusion weighted magnetic resonance imaging (b=0, 1000s/mm 2 ), which generated ADC maps. Whole-volume histogram analysis was performed on ADC maps and 7 characteristic parameters were obtained. All those patients underwent surgery and postoperative pathologic T and N stages were determined. Four parameters, including skew, kurtosis, s-sD av and sample number, showed significant differences among gastric cancers at different T and N stages. Most parameters correlated with T and N stages significantly and worked in differentiating gastric cancers at different T or N stages. Especially skew yielded a sensitivity of 0.758, a specificity of 0.810, and an area under the curve (AUC) of 0.802 for differentiating gastric cancers with and without lymph node metastasis (P<0.001). All the parameters, except AUC low , showed good or excellent inter-observer agreement with intra-class correlation coefficients ranging from 0.710 to 0.991. Characteristic parameters derived from whole-volume ADC histogram analysis could help assessing preoperative T and N stages of gastric cancers. Copyright © 2017. Published by Elsevier Inc.

  6. Mechanical Player Load™ using trunk-mounted accelerometry in football: Is it a reliable, task- and player-specific observation?

    PubMed

    Barreira, Paulo; Robinson, Mark A; Drust, Barry; Nedergaard, Niels; Raja Azidin, Raja Mohammed Firhad; Vanrenterghem, Jos

    2017-09-01

    The aim of the present study was to examine reliability and construct convergent validity of Player Load™ (PL) from trunk-mounted accelerometry, expressed as a cumulative measure and an intensity measure (PL · min - 1 ). Fifteen male participants twice performed an overground football match simulation that included four different multidirectional football actions (jog, side cut, stride and sprint) whilst wearing a trunk-mounted accelerometer inbuilt in a global positioning system unit. Results showed a moderate-to-high reliability as indicated by the intra-class correlation coefficient (0.806-0.949) and limits of agreement. Convergent validity analysis showed considerable between-participant variation (coefficient of variation range 14.5-24.5%), which was not explained from participant demographics despite a negative association with body height for the stride task. Between-task variations generally showed a moderate correlation between ranking of participants for PL (0.593-0.764) and PL · min - 1 (0.282-0.736). It was concluded that monitoring PL ® in football multidirectional actions presents moderate-to-high reliability, that between-participant variability most likely relies on the individual's locomotive skills and not their anthropometrics, and that the intensity of a task expressed by PL · min - 1 is largely related to the running velocity of the task.

  7. Reliability of the Pictorial Scale of Perceived Movement Skill Competence in 2 Diverse Samples of Young Children.

    PubMed

    Barnett, Lisa M; Robinson, Leah E; Webster, E Kipling; Ridgers, Nicola D

    2015-08-01

    The purpose was to determine the reliability of an instrument designed to assess young children's perceived movement skill competence in 2 diverse samples. A pictorial instrument assessed 12 perceived Fundamental Movement Skills (FMS) based on the Test of Gross Motor Development 2nd edition. Intra-Class Correlations (ICC) and internal consistency analyses were conducted. Paired sample t tests assessed change in mean perceived skill scores. Bivariate correlations between the intertrial difference and the mean of the trials explored proportional bias. Sample 1 (S1) were culturally diverse Australian children (n = 111; 52% boys) aged 5 to 8 years (mean = 6.4, SD = 1.0) with educated parents. Sample 2 (S2) were racially diverse and socioeconomically disadvantaged American children (n = 110; 57% boys) aged 5 to 10 years (mean = 6.8, SD = 1.1). For all children, the internal consistency for 12 FMS was acceptable (S1 = 0.72, 0.75, S2 = 0.66, 0.67). ICCs were higher in S1 (0.73) than S2 (0.50). Mean changes between trials were small. There was little evidence of proportional bias. Lower values in S2 may be due to differences in study demographic and execution. While the instrument demonstrated reliability/internal consistency, further work is recommended in diverse samples.

  8. A comparative analysis of Patient-Reported Expanded Disability Status Scale tools.

    PubMed

    Collins, Christian DE; Ivry, Ben; Bowen, James D; Cheng, Eric M; Dobson, Ruth; Goodin, Douglas S; Lechner-Scott, Jeannette; Kappos, Ludwig; Galea, Ian

    2016-09-01

    Patient-Reported Expanded Disability Status Scale (PREDSS) tools are an attractive alternative to the Expanded Disability Status Scale (EDSS) during long term or geographically challenging studies, or in pressured clinical service environments. Because the studies reporting these tools have used different metrics to compare the PREDSS and EDSS, we undertook an individual patient data level analysis of all available tools. Spearman's rho and the Bland-Altman method were used to assess correlation and agreement respectively. A systematic search for validated PREDSS tools covering the full EDSS range identified eight such tools. Individual patient data were available for five PREDSS tools. Excellent correlation was observed between EDSS and PREDSS with all tools. A higher level of agreement was observed with increasing levels of disability. In all tools, the 95% limits of agreement were greater than the minimum EDSS difference considered to be clinically significant. However, the intra-class coefficient was greater than that reported for EDSS raters of mixed seniority. The visual functional system was identified as the most significant predictor of the PREDSS-EDSS difference. This analysis will (1) enable researchers and service providers to make an informed choice of PREDSS tool, depending on their individual requirements, and (2) facilitate improvement of current PREDSS tools. © The Author(s), 2015.

  9. Development and psychometric testing of a trans-professional evidence-based practice profile questionnaire.

    PubMed

    McEvoy, Maureen Patricia; Williams, Marie T; Olds, Timothy Stephen

    2010-01-01

    Previous survey tools operationalising knowledge, attitudes or beliefs about evidence-based practice (EBP) have shortcomings in content, psychometric properties and target audience. This study developed and psychometrically assessed a self-report trans-professional questionnaire to describe an EBP profile. Sixty-six items were collated from existing EBP questionnaires and administered to 526 academics and students from health and non-health backgrounds. Principal component factor analysis revealed the presence of five factors (Relevance, Terminology, Confidence, Practice and Sympathy). Following expert panel review and pilot testing, the 58-item final questionnaire was disseminated to 105 subjects on two occasions. Test-retest and internal reliability were quantified using intra-class correlation coefficients (ICCs) and Cronbach's alpha, convergent validity against a commonly used EBP questionnaire by Pearson's correlation coefficient and discriminative validity via analysis of variance (ANOVA) based on exposure to EBP training. The final questionnaire demonstrated acceptable internal consistency (Cronbach's alpha 0.96), test-retest reliability (ICCs range 0.77-0.94) and convergent validity (Practice 0.66, Confidence 0.80 and Sympathy 0.54). Three factors (Relevance, Terminology and Confidence) distinguished EBP exposure groups (ANOVA p < 0.001-0.004). The evidence-based practice profile (EBP(2)) questionnaire is a reliable instrument with the ability to discriminate for three factors, between respondents with differing EBP exposures.

  10. The reliability and validity of the Complex Task Performance Assessment: A performance-based assessment of executive function.

    PubMed

    Wolf, Timothy J; Dahl, Abigail; Auen, Colleen; Doherty, Meghan

    2017-07-01

    The objective of this study was to evaluate the inter-rater reliability, test-retest reliability, concurrent validity, and discriminant validity of the Complex Task Performance Assessment (CTPA): an ecologically valid performance-based assessment of executive function. Community control participants (n = 20) and individuals with mild stroke (n = 14) participated in this study. All participants completed the CTPA and a battery of cognitive assessments at initial testing. The control participants completed the CTPA at two different times one week apart. The intra-class correlation coefficient (ICC) for inter-rater reliability for the total score on the CTPA was .991. The ICCs for all of the sub-scores of the CTPA were also high (.889-.977). The CTPA total score was significantly correlated to Condition 4 of the DKEFS Color-Word Interference Test (p = -.425), and the Wechsler Test of Adult Reading (p  = -.493). Finally, there were significant differences between control subjects and individuals with mild stroke on the total score of the CTPA (p = .007) and all sub-scores except interpretation failures and total items incorrect. These results are also consistent with other current executive function performance-based assessments and indicate that the CTPA is a reliable and valid performance-based measure of executive function.

  11. Cross-cultural adaptation and validation of the Italian Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ).

    PubMed

    Bucci, Rosaria; Rongo, Roberto; Zito, Eugenio; Galeotti, Angela; Valletta, Rosa; D'Antò, Vincenzo

    2015-03-01

    To validate and cross-culturally adapt the Italian version of the Psychological Impact of Dental Aesthetics Questionnaire (PIDAQ) among Italian young adults. After translation, back translation, and cross-cultural adaptation of the English PIDAQ, a first version of the Italian questionnaire was pretested. The final Italian PIDAQ was administered to 598 subjects aged 18-30 years, along with two other instruments: the aesthetic component of the index of orthodontic treatment need (IOTN-AC) and the perception of occlusion scale (POS), which identified the self-reporting grade of malocclusion. Structural validity was assessed by means of factorial analysis, internal consistency was measured with Cronbach's alpha coefficient (α), convergent validity was assessed by means of Spearman correlation, and test-retest reliability was calculated with intra-class correlation coefficient (ICC) and standard measurement error. Criterion validity was evaluated by multivariate and univariate analysis of variance with Bonferroni post hoc tests. The α of the Italian PIDAQ domains ranged between 0.79 and 0.92. The ICC was between 0.81 and 0.90. The mean scores of each PIDAQ domain showed a statistically significant difference when analysed according to the IOTN-AC and POS scores. The satisfactory psychometric properties make PIDAQ a usable tool for future studies on oral health-related quality of life among Italian young adults.

  12. The Computerized Perceptual Motor Skills Assessment: A new visual perceptual motor skills evaluation tool for children in early elementary grades.

    PubMed

    Howe, Tsu-Hsin; Chen, Hao-Ling; Lee, Candy Chieh; Chen, Ying-Dar; Wang, Tien-Ni

    2017-10-01

    Visual perceptual motor skills have been proposed as underlying courses of handwriting difficulties. However, there is no evaluation tool currently available to assess these skills comprehensively and to serve as a sensitive measure. The purpose of this study was to validate the Computerized Perceptual Motor Skills Assessment (CPMSA), a newly developed evaluation tool for children in early elementary grades. Its test-retest reliability, concurrent validity, discriminant validity, and responsiveness were examined in 43 typically developing children and 26 children with handwriting difficulty. The CPMSA demonstrated excellent reliability across all subtests with intra-class correlation coefficients (ICCs)≥0.80. Significant moderate correlations between the domains of the CPMSA and corresponding gold standards including Beery VMI, the TVPS-3, and the eye-hand coordination subtest of the DTVP-2 demonstrated good concurrent validity. In addition, the CPMSA showed evidence of discriminant validity in samples of children with and without handwriting difficulty. This article provides evidence in support of the CPMSA. The CPMSA is a reliable, valid, and promising measure of visual perceptual motor skills for children in early elementary grades. Directions for future study and improvements to the assessment are discussed. Copyright © 2017. Published by Elsevier Ltd.

  13. Validation of the Chinese translation of the 6-item De Jong Gierveld Loneliness Scale in elderly Chinese.

    PubMed

    Leung, Grace Tak Yu; de Jong Gierveld, Jenny; Lam, Linda Chiu Wa

    2008-12-01

    This study aims to develop and validate a Chinese translation of the 6-item De Jong Gierveld Loneliness Scale - a widely used instrument to measure loneliness - specifically determining its psychometric properties in community-dwelling Chinese elders in Hong Kong. The relationships between loneliness and several clinical variables are also assessed. The English version was translated into Chinese. Content validity was established by group discussion and Delphi panel. The questionnaire was administered to 103 Hong Kong Chinese community-dwelling elders. Statistical analysis was performed to test the reliability and validity of the scale. The content validity was high as shown by the results of the Delphi panel. Cronbach's alpha of the 6-item scale was 0.76. For the inter-rater reliability of the six items, the intra-class correlation coefficients ranged from 0.98 to 1.00. The emotional loneliness subscale significantly correlated with the social loneliness subscale (rho = 0.37; p < 0.001). In using a direct question to measure loneliness, 21 participants (20%) reported that they were lonely. The overall loneliness scale score significantly correlated with the answers on the direct question of loneliness (rpb = 0.71; p < 0.001). The overall loneliness score showed significant correlation with Cornell Scale for Depression in Dementia (rho = 0.29; p = 0.003), current smoking status (rpb = 0.24; p = 0.014), and some objective social characteristics. The Chinese version of the 6-item De Jong Gierveld Loneliness Scale is a reliable and valid measure of loneliness in Chinese elders.

  14. Psychometric properties of the Iranian interview-administered version of the World Health Organization's Quality of Life Questionnaire (WHOQOL-BREF): a population-based study.

    PubMed

    Nedjat, Saharnaz; Montazeri, Ali; Holakouie, Kourosh; Mohammad, Kazem; Majdzadeh, Reza

    2008-03-21

    The objective of the current study was to translate and validate the Iranian version of the WHOQOL-BREF. A forward-backward translation procedure was followed to develop the Iranian version of the questionnaire. A stratified random sample of individuals aged 18 and over completed the questionnaire in Tehran, Iran. Psychometric properties of the instrument including reliability (internal consistency, and test-retest analysis), validity (known groups' comparison and convergent validity), and items' correlation with their hypothesized domains were assessed. In all 1164 individuals entered into the study. The mean age of the participants was 36.6 (SD = 13.2) years, and the mean years of their formal education was 10.7 (SD = 4.4). In general the questionnaire received well and all domains met the minimum reliability standards (Cronbach's alpha and intra-class correlation > 0.7), except for social relationships (alpha = 0.55). Performing known groups' comparison analysis, the results indicated that the questionnaire discriminated well between subgroups of the study samples differing in their health status. Since the WHOQOL-BREF demonstrated statistically significant correlation with the Iranian version of the SF-36 as expected, the convergent validity of the questionnaire was found to be desirable. Correlation matrix also showed satisfactory results in all domains except for social relationships. This study has provided some preliminary evidence of the reliability and validity of the WHOQOL-BREF to be used in Iran, though further research is required to challenge the problems of reliability in one of the dimensions and the instrument's factor structure.

  15. Validity and reliability of the Arabic version of the Household Food Insecurity Access Scale in rural Lebanon.

    PubMed

    Naja, Farah; Hwalla, Nahla; Fossian, Talar; Zebian, Dina; Nasreddine, Lara

    2015-02-01

    To assess the validity and reliability of the Arabic version of the Household Food Insecurity Access Scale (HFIAS) in rural Lebanon. A cross-sectional study on a sample of households with at least one child aged 0-2 years. In a one-to-one interview, participants completed an adapted Arabic version of the HFIAS. In order to evaluate the validity of the HFIAS, basic sociodemographic information, anthropometric measurements of the mother and child, and dietary intake data of the child were obtained. In order to examine reproducibility, the HFIAS was re-administered after 3 months. Rural Lebanon. Mother and child pairs (n 150). Factor analysis of HFIAS items revealed two factors: 'insufficient food quality' and 'insufficient food quantity'. Using Pearson's correlation, food insecurity was inversely associated with mother's and father's education levels, number of cars and electrical appliances in the household, income, weight-for-age and length-for-age of the child and the child's dietary adequacy. In contrast, mother's BMI and crowding index were positively associated with food insecurity scores (P < 0·05 for all correlations). Cronbach's α of the scale was 0·91. A moderate correlation was observed between the two administrations of the questionnaire (intra-class correlation = 0·58; P < 0·05). Our findings indicated that the adapted Arabic version of the HFIAS is a valid and reliable tool to assess food insecurity in rural Lebanon, lending further evidence to the utility of the HFIAS in assessing food insecurity in culturally diverse populations.

  16. Measurement characteristics of the childhood Asthma-Control Test and a shortened, child-only version

    PubMed Central

    Bime, Christian; Gerald, Joe K; Wei, Christine Y; Holbrook, Janet T; Teague, William G; Wise, Robert A; Gerald, Lynn B

    2016-01-01

    The childhood Asthma-Control Test (C-ACT) is validated for assessing asthma control in paediatric asthma. Among children aged 4–11 years, the C-ACT requires the simultaneous presence of both parent and child. There is an unmet need for a tool that can be used to assess asthma control in children when parents or caregivers are not present such as in the school setting. We assessed the psychometric properties and estimated the minimally important difference (MID) of the C-ACT and a modified version, comprising only the child responses (C-ACTc). Asthma patients aged 6–11 years (n=161) from a previously completed multicenter randomised trial were included. Demographic information, spirometry and questionnaire scores were obtained at baseline and during follow-up. Participants or their guardians kept a daily asthma diary. Internal consistency reliabilities of the C-ACT and C-ACTc were 0.76 and 0.67 (Cronbach’s α), respectively. Test–retest reliabilities of the C-ACT and C-ACTc were 0.72 and 0.66 (intra-class correlation), respectively. Significant correlations were noted between C-ACT scores and ACQ scores (Spearman’s correlation r=−0.56, 95% CI (−0.66, −0.44), P<0.001). The strength of the correlation between C-ACTc scores and ACQ scores was weaker (Spearman’s correlation r=−0.46, 95% CI (−0.58, −0.33), P<0.001). We estimated the MID for the C-ACT and C-ACTc to be 2 points and 1 point, respectively. Among asthma patients aged 6–11 years, the C-ACT had good psychometric properties. The psychometric properties of a shortened child-only version (C-ACTc), although acceptable, are not as strong. PMID:27763622

  17. Two-colour chewing gum mixing ability test for evaluating masticatory performance in children with mixed dentition: validity and reliability study.

    PubMed

    Kaya, M S; Güçlü, B; Schimmel, M; Akyüz, S

    2017-11-01

    The unappealing taste of the chewing material and the time-consuming repetitive task in masticatory performance tests using artificial foodstuff may discourage children from performing natural chewing movements. Therefore, the aim was to determine the validity and reliability of a two-colour chewing gum mixing ability test for masticatory performance (MP) assessment in mixed dentition children. Masticatory performance was tested in two groups: systemically healthy fully dentate young adults and children in mixed dentition. Median particle size was assessed using a comminution test, and a two-colour chewing gum mixing ability test was applied for MP analysis. Validity was tested with Pearson correlation, and reliability was tested with intra-class correlation coefficient, Pearson correlation and Bland-Altman plots. Both comminution and two-colour chewing gum mixing ability tests revealed statistically significant MP differences between children (n = 25) and adults (n = 27, both P < 0·01). Pearson correlation between comminution and two-colour chewing gum mixing ability tests was positive and significant (r = 0·418, P = 0·002). Correlations for interobserver reliability and test-retest values were significant (r = 0·990, P = 0·0001 and r = 0·995, P = 0·0001). Although both methods could discriminate MP differences, the comminution test detected these differences generally in a wider range compared to two-colour chewing gum mixing ability test. However, considering the high reliability of the results, the two-colour chewing gum mixing ability test can be used to assess masticatory performance in children, especially at non-clinical settings. © 2017 John Wiley & Sons Ltd.

  18. Team performance in resuscitation teams: Comparison and critique of two recently developed scoring tools☆

    PubMed Central

    McKay, Anthony; Walker, Susanna T.; Brett, Stephen J.; Vincent, Charles; Sevdalis, Nick

    2012-01-01

    Background and aim Following high profile errors resulting in patient harm and attracting negative publicity, the healthcare sector has begun to focus on training non-technical teamworking skills as one way of reducing the rate of adverse events. Within the area of resuscitation, two tools have been developed recently aiming to assess these skills – TEAM and OSCAR. The aims of the study reported here were:1.To determine the inter-rater reliability of the tools in assessing performance within the context of resuscitation.2.To correlate scores of the same resuscitation teams episodes using both tools, thereby determining their concurrent validity within the context of resuscitation.3.To carry out a critique of both tools and establish how best each one may be utilised. Methods The study consisted of two phases – reliability assessment; and content comparison, and correlation. Assessments were made by two resuscitation experts, who watched 24 pre-recorded resuscitation simulations, and independently rated team behaviours using both tools. The tools were critically appraised, and correlation between overall score surrogates was assessed. Results Both OSCAR and TEAM achieved high levels of inter-rater reliability (in the form of adequate intra-class coefficients) and minor significant differences between Wilcoxon tests. Comparison of the scores from both tools demonstrated a high degree of correlation (and hence concurrent validity). Finally, critique of each tool highlighted differences in length and complexity. Conclusion Both OSCAR and TEAM can be used to assess resuscitation teams in a simulated environment, with the tools correlating well with one another. We envisage a role for both tools – with TEAM giving a quick, global assessment of the team, but OSCAR enabling more detailed breakdown of the assessment, facilitating feedback, and identifying areas of weakness for future training. PMID:22561464

  19. Simultaneous Validation of Seven Physical Activity Questionnaires Used in Japanese Cohorts for Estimating Energy Expenditure: A Doubly Labeled Water Study.

    PubMed

    Sasai, Hiroyuki; Nakata, Yoshio; Murakami, Haruka; Kawakami, Ryoko; Nakae, Satoshi; Tanaka, Shigeho; Ishikawa-Takata, Kazuko; Yamada, Yosuke; Miyachi, Motohiko

    2018-04-28

    Physical activity questionnaires (PAQs) used in large-scale Japanese cohorts have rarely been simultaneously validated against the gold standard doubly labeled water (DLW) method. This study examined the validity of seven PAQs used in Japan for estimating energy expenditure against the DLW method. Twenty healthy Japanese adults (9 men; mean age, 32.4 [standard deviation {SD}, 9.4] years, mainly researchers and students) participated in this study. Fifteen-day daily total energy expenditure (TEE) and basal metabolic rate (BMR) were measured using the DLW method and a metabolic chamber, respectively. Activity energy expenditure (AEE) was calculated as TEE - BMR - 0.1 × TEE. Seven PAQs were self-administered to estimate TEE and AEE. The mean measured values of TEE and AEE were 2,294 (SD, 318) kcal/day and 721 (SD, 161) kcal/day, respectively. All of the PAQs indicated moderate-to-strong correlations with the DLW method in TEE (rho = 0.57-0.84). Two PAQs (Japan Public Health Center Study [JPHC]-PAQ Short and JPHC-PAQ Long) showed significant equivalence in TEE and moderate intra-class correlation coefficients (ICC). None of the PAQs showed significantly equivalent AEE estimates, with differences ranging from -547 to 77 kcal/day. Correlations and ICCs in AEE were mostly weak or fair (rho = 0.02-0.54, and ICC = 0.00-0.44). Only JPHC-PAQ Short provided significant and fair agreement with the DLW method. TEE estimated by the PAQs showed moderate or strong correlations with the results of DLW. Two PAQs showed equivalent TEE and moderate agreement. None of the PAQs showed equivalent AEE estimation to the gold standard, with weak-to-fair correlations and agreements. Further studies with larger sample sizes are needed to confirm these findings.

  20. Reliability of a novel thermal imaging system for temperature assessment of healthy feet.

    PubMed

    Petrova, N L; Whittam, A; MacDonald, A; Ainarkar, S; Donaldson, A N; Bevans, J; Allen, J; Plassmann, P; Kluwe, B; Ring, F; Rogers, L; Simpson, R; Machin, G; Edmonds, M E

    2018-01-01

    Thermal imaging is a useful modality for identifying preulcerative lesions ("hot spots") in diabetic foot patients. Despite its recognised potential, at present, there is no readily available instrument for routine podiatric assessment of patients at risk. To address this need, a novel thermal imaging system was recently developed. This paper reports the reliability of this device for temperature assessment of healthy feet. Plantar skin foot temperatures were measured with the novel thermal imaging device (Diabetic Foot Ulcer Prevention System (DFUPS), constructed by Photometrix Imaging Ltd) and also with a hand-held infrared spot thermometer (Thermofocus® 01500A3, Tecnimed, Italy) after 20 min of barefoot resting with legs supported and extended in 105 subjects (52 males and 53 females; age range 18 to 69 years) as part of a multicentre clinical trial. The temperature differences between the right and left foot at five regions of interest (ROIs), including 1st and 4th toes, 1st, 3rd and 5th metatarsal heads were calculated. The intra-instrument agreement (three repeated measures) and the inter-instrument agreement (hand-held thermometer and thermal imaging device) were quantified using intra-class correlation coefficients (ICCs) and the 95% confidence intervals (CI). Both devices showed almost perfect agreement in replication by instrument. The intra-instrument ICCs for the thermal imaging device at all five ROIs ranged from 0.95 to 0.97 and the intra-instrument ICCs for the hand-held-thermometer ranged from 0.94 to 0.97. There was substantial to perfect inter-instrument agreement between the hand-held thermometer and the thermal imaging device and the ICCs at all five ROIs ranged between 0.94 and 0.97. This study reports the performance of a novel thermal imaging device in the assessment of foot temperatures in healthy volunteers in comparison with a hand-held infrared thermometer. The newly developed thermal imaging device showed very good agreement in repeated temperature assessments at defined ROIs as well as substantial to perfect agreement in temperature assessment with the hand-held infrared thermometer. In addition to the reported non-inferior performance in temperature assessment, the thermal imaging device holds the potential to provide an instantaneous thermal image of all sites of the feet (plantar, dorsal, lateral and medial views). Diabetic Foot Ulcer Prevention System NCT02317835, registered December 10, 2014.

  1. Region of Interest Correction Factors Improve Reliability of Diffusion Imaging Measures Within and Across Scanners and Field Strengths

    PubMed Central

    Venkatraman, Vijay K; Gonzalez, Christopher E.; Landman, Bennett; Goh, Joshua; Reiter, David A.; An, Yang; Resnick, Susan M.

    2017-01-01

    Diffusion tensor imaging (DTI) measures are commonly used as imaging markers to investigate individual differences in relation to behavioral and health-related characteristics. However, the ability to detect reliable associations in cross-sectional or longitudinal studies is limited by the reliability of the diffusion measures. Several studies have examined reliability of diffusion measures within (i.e. intra-site) and across (i.e. inter-site) scanners with mixed results. Our study compares the test-retest reliability of diffusion measures within and across scanners and field strengths in cognitively normal older adults with a follow-up interval less than 2.25 years. Intra-class correlation (ICC) and coefficient of variation (CoV) of fractional anisotropy (FA) and mean diffusivity (MD) were evaluated in sixteen white matter and twenty-six gray matter bilateral regions. The ICC for intra-site reliability (0.32 to 0.96 for FA and 0.18 to 0.95 for MD in white matter regions; 0.27 to 0.89 for MD and 0.03 to 0.79 for FA in gray matter regions) and inter-site reliability (0.28 to 0.95 for FA in white matter regions, 0.02 to 0.86 for MD in gray matter regions) with longer follow-up intervals were similar to earlier studies using shorter follow-up intervals. The reliability of across field strengths comparisons was lower than intra- and inter-site reliability. Within and across scanner comparisons showed that diffusion measures were more stable in larger white matter regions (> 1500 mm3). For gray matter regions, the MD measure showed stability in specific regions and was not dependent on region size. Linear correction factor estimated from cross-sectional or longitudinal data improved the reliability across field strengths. Our findings indicate that investigations relating diffusion measures to external variables must consider variable reliability across the distinct regions of interest and that correction factors can be used to improve consistency of measurement across field strengths. An important result of this work is that inter-scanner and field strength effects can be partially mitigated with linear correction factors specific to regions of interest. These data-driven linear correction techniques can be applied in cross-sectional or longitudinal studies. PMID:26146196

  2. Three-dimensional assessment of the asymptomatic and post-stroke shoulder: intra-rater test-retest reliability and within-subject repeatability of the palpation and digitization approach.

    PubMed

    Pain, Liza A M; Baker, Ross; Sohail, Qazi Zain; Richardson, Denyse; Zabjek, Karl; Mogk, Jeremy P M; Agur, Anne M R

    2018-03-23

    Altered three-dimensional (3D) joint kinematics can contribute to shoulder pathology, including post-stroke shoulder pain. Reliable assessment methods enable comparative studies between asymptomatic shoulders of healthy subjects and painful shoulders of post-stroke subjects, and could inform treatment planning for post-stroke shoulder pain. The study purpose was to establish intra-rater test-retest reliability and within-subject repeatability of a palpation/digitization protocol, which assesses 3D clavicular/scapular/humeral rotations, in asymptomatic and painful post-stroke shoulders. Repeated measurements of 3D clavicular/scapular/humeral joint/segment rotations were obtained using palpation/digitization in 32 asymptomatic and six painful post-stroke shoulders during four reaching postures (rest/flexion/abduction/external rotation). Intra-class correlation coefficients (ICCs), standard error of the measurement and 95% confidence intervals were calculated. All ICC values indicated high to very high test-retest reliability (≥0.70), with lower reliability for scapular anterior/posterior tilt during external rotation in asymptomatic subjects, and scapular medial/lateral rotation, humeral horizontal abduction/adduction and axial rotation during abduction in post-stroke subjects. All standard error of measurement values demonstrated within-subject repeatability error ≤5° for all clavicular/scapular/humeral joint/segment rotations (asymptomatic ≤3.75°; post-stroke ≤5.0°), except for humeral axial rotation (asymptomatic ≤5°; post-stroke ≤15°). This noninvasive, clinically feasible palpation/digitization protocol was reliable and repeatable in asymptomatic shoulders, and in a smaller sample of painful post-stroke shoulders. Implications for Rehabilitation In the clinical setting, a reliable and repeatable noninvasive method for assessment of three-dimensional (3D) clavicular/scapular/humeral joint orientation and range of motion (ROM) is currently required. The established reliability and repeatability of this proposed palpation/digitization protocol will enable comparative 3D ROM studies between asymptomatic and post-stroke shoulders, which will further inform treatment planning. Intra-rater test-retest repeatability, which is measured by the standard error of the measure, indicates the range of error associated with a single test measure. Therefore, clinicians can use the standard error of the measure to determine the "true" differences between pre-treatment and post-treatment test scores.

  3. The "Down the PC" view - A new tool to assess screw positioning in the posterior column of the acetabulum.

    PubMed

    Osterhoff, G; Amiri, S; Unno, F; Dodd, A; Guy, P; O'Brien, P J; Lefaivre, K A

    2015-08-01

    Minimal-invasive placement of screws into the posterior column of the acetabulum (PC) is challenging. Due to the saddle-shaped curvature of the medial cortical border of the PC, the standard fluoroscopic views of the pelvis cannot provide the desired safety during screw insertion. The aim of this study was to define a view tangentially to the medial cortex of the PC and to evaluate its accuracy and inter-observer reproducibility. Radio-dense markers on the medial cortex of the PC along the axis of a PC screw were brought in line and landmarks of the new "Down the PC" view were determined. Kirschner wires were placed into the PC of a pelvis composite model and five pelvic cadaver specimens in a total of 34 different correct and incorrect positions. Based on either only the "Down the PC" view, only the standard views, or a combination of both, three fellowship-trained orthopaedic surgeons had to decide if the inserted wires were in bone in the posterior column or had exited cortex, and if they penetrated the acetabulum. Sensitivity, specificity, and the intra-class correlation coefficient were calculated. A view using three radiographic landmarks (pelvic brim, medial cortical wall of the body of the ischium, ischial spine) was found. Sensitivity and specificity to detect perforation out of the bone were 1.00 and 0.97 for the "Down the PC" view, 0.46 and 0.97 if only the standard views were used, and 1.00 and 0.95 for a combination of both. Sensitivity and specificity to detect intra-articular wire placement were 1.00 and 0.96 for the "Down the PC" view, 0.72 and 0.95 if only the standard views were used, and 0.94 and 0.99 for a combination of both. Inter-observer agreement using only the "Down the PC" view was excellent with an ICC of 0.92 for perforation and ICC of 0.82 for intra-articular wire placement. The "Down the PC" view is a useful addendum in the orthopaedic trauma surgeon's tool box. Using simple landmarks, it is easily to reproduce and thereby shows excellent accuracy and inter-observer agreement in order to detect medial perforation or intra-articular implant position. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Reproducibility of African giant pouched rats detecting Mycobacterium tuberculosis.

    PubMed

    Ellis, Haylee; Mulder, Christiaan; Valverde, Emilio; Poling, Alan; Edwards, Timothy

    2017-04-24

    African pouched rats sniffing sputum samples provided by local clinics have significantly increased tuberculosis case findings in Tanzania and Mozambique. The objective of this study was to determine the reproducibility of rat results. Over an 18-month period 11,869 samples were examined by the rats. Intra-rater reliability was assessed through Yule's Q. Inter-rater reliability was assessed with Krippendorff's alpha. Intra-rater reliability was high, with a mean Yule's Q of 0.9. Inter-rater agreement was fair, with Krippendorf's alpha ranging from 0.15 to 0.45. Both Intra- and Inter-rater reliability was independent of the sex of the animals, but they were positively correlated with age. Both intra- and inter-rater agreement was lowest for samples designated as smear-negative by the clinics. Overall, the reproducibility of tuberculosis detection rat results was fair and diagnostic results were therefore independent of the rats used.

  5. Evaluating the utility of vegetation indices to monitoring forests in South America, Western & Central Africa, and Southeast Asia

    NASA Astrophysics Data System (ADS)

    Cherrington, E. A.; Vincent, G.; Barbier, N.; Pélissier, R.; Sabatier, D.; Berger, U.

    2017-12-01

    In recent years, there has been controversy regarding applying vegetation indices (VIs) for monitoring tropical forests because of data artefacts related to sun-sensor geometry issues. One means of addressing the issue is comparing the VI variation of tropical forests in similar latitudes. That is, if intra-annual variation in VIs is not driven by real structural and biological changes in the vegetation, then one would expect that forests on the same latitudes should display similar patterns of VI variation. Data from multiple vegetation indices (from MODIS and SPOT VEGETATION) were analyzed over three ten degree by ten degree tiles covering the Guianas, western-central Africa, and northern Borneo in Southeast Asia. In addition to comparing the intra-annual trends across the three regions, the trends were also compared with intra-annual patterns of temporal variation, to see if these explained the VI variation. Those analyses showed that not only did the VI variation across the three regions differ significantly, but the patterns in VI variation for at least two of the three regions were largely correlated with intra-annual variation in environmental factors such as rainfall or light availability. For the Guianas, the pattern of VI variation was largely correlated with the variation in solar radiation, while for western-central Africa, the pattern of variation was more correlated to the variation in rainfall. In contrast, for northern Borneo, the pattern of VI variation did not correlate well with either variation in solar elevation or with intra-annual variation in environmental factors. Firstly, the data would seem to suggest that the patterns of variation in VI data for tropical forests are not strongly biased by artefacts related to sun-sensor geometry effects. More importantly, however, the results also suggest that the phenological of forests in both the Guianas and in western-central Africa are governed by different environmental regimes. That is to say, the forests in the Guianas appear to be light-limited, whereas in contrast, the forests in western-central Africa appear to be moisture-limited. This research suggests that vegetation index data - when corrected for artefacts related to bi-directional effects - can indeed be used to study patterns of temporal variation of forests in the tropics.

  6. Intra-cystic concentrations of albendazole-sulphoxide in human cystic echinococcosis: a systematic review and analysis of individual patient data.

    PubMed

    Lötsch, Felix; Naderer, Judith; Skuhala, Tomislava; Groger, Mirjam; Auer, Herbert; Kaczirek, Klaus; Waneck, Fredrik; Ramharter, Michael

    2016-08-01

    Cystic echinococcosis (CE) is a widespread zoonosis caused by the species complex Echinococcus granulosus. Albendazole (ABZ)-the first-line anthelminthic drug for medical treatment of CE-is metabolized in vivo to the active derivative ABZ-sulphoxide (ABZ-SO). Target-site ABZ-SO concentrations in the hydatid cyst mediate the anthelminthic effect in CE. Primary outcome of this systematic review of individual patient data was the intra-cystic ABZ-SO concentration stratified by cyst size, location, calcification status and use of praziquantel. Studies reporting intra-cystic ABZ-SO concentrations in humans were identified by a systematic search. A pooled analysis of individual patient data was performed to assess intra-cystic concentrations. Pharmacokinetic data of 121 individual cysts were analysed. There was no correlation between plasma and intra-cystic ABZ-SO concentrations (rho = -0.03, p = 0.76). Intra-cystic drug concentrations were also not associated with sex and treatment duration. Use of praziquantel in combination with ABZ was associated with higher plasma (median 540 vs. 240 μg/L; p = 0.04) but not intra-cystic ABZ-SO concentrations (median 220 vs. 199 μg/L; p = 0.36). Relative drug concentrations in hepatic cysts were higher than in other cysts (0.8 vs. 0.4; p = 0.05). Intra-cystic concentrations were higher in calcified than non-calcified cysts (median 897 vs. 245 μg/L; p = 0.03). There was a trend towards higher intra-cystic concentrations in smaller sized cysts (β = -17.2 μg/L/cm; 95th CI, -35.9 to 1.6; p = 0.07). This study demonstrates that mean intra-cystic drug concentrations are similar to plasma concentrations on a population level. However, in individual patients plasma concentrations are not directly predictive for intra-cystic concentrations. The use of booster drugs was not associated with higher intra-cystic ABZ-SO concentrations in this analysis.

  7. 1-Hydroxypyrene concentrations in first morning voids and 24-h composite urine: intra- and inter-individual comparisons.

    PubMed

    Han, In-Kyu; Duan, Xiaoli; Zhang, Lin; Yang, Hongbiao; Rhoads, George G; Wei, Fusheng; Zhang, Junfeng

    2008-09-01

    Urinary 1-hydroxypyrene (1-OHP) has been suggested as an exposure biomarker for polycyclic aromatic hydrocarbons (PAHs). However, it remains unknown whether a first morning urine sample can be used to reflect average exposure. In this paper, we examine intra-individual differences and inter-individual associations between first morning voids and 24-h composite urine samples. The analysis was performed using data collected from 100 adults who had a wide range of PAH exposure due to differences in their occupation, e.g., coke oven workers vs. non-coke oven workers. For each subject, all the urine voids within each of two 24-h measurement periods were collected. Results showed a significant (40% to 62%) intra-individual difference between first morning voids and 24-h urinary 1-OHP concentrations (in ng/ml urine). Creatinine adjustments of 1-OHP concentrations (in micromol/mol urinary creatinine) reduced the intra-individual difference by approximately 10%. Across all the subjects, a high overall correlation (r=0.76) was observed between first morning and 24-h average 1-OHP concentrations. Work environment and sampling season were found to significantly affect the relationship between first morning and 24-h 1-OHP concentrations. An increase of 1 ng/ml of first morning urinary 1-OHP predicted an increase of 0.5 and 0.25 ng/ml of 24-h urinary 1-OHP for coke oven workers and non-coke oven workers, respectively. Data collected in a winter season showed a higher correlation between first morning and 24-h concentrations than data collected in a fall season. Creatinine adjustments did not significantly improve overall correlations between first morning void and 24-h measurements, but increased total variances for 24-h urines explained by first morning urines in coke workers.

  8. Intra-event variability of Escherichia coli and total suspended solids in urban stormwater runoff.

    PubMed

    McCarthy, D T; Hathaway, J M; Hunt, W F; Deletic, A

    2012-12-15

    Sediment levels are important for environmental health risk assessments of surface water bodies, while faecal pollution can introduce significant public health risks for users of these systems. Urban stormwater is one of the largest sources of contaminants to surface waters, yet the fate and transport of these contaminants (especially those microbiological) have received little attention in the literature. Stormwater runoff from five urbanized catchments were monitored for pathogen indicator bacteria and total suspended solids in two developed countries. Multiple discrete samples were collected during each storm event, allowing an analysis of intra-event characteristics such as initial concentration, peak concentration, maximum rate of change, and relative confidence interval. The data suggest that a catchment's area influences pollutant characteristics, as larger catchments have more complex stormwater infrastructure and more variable pollutant sources. The variability of total suspended solids for many characteristics was similar to Escherichia coli, indicating that the variability of E. coli may not be substantially higher than that of other pollutants as initially speculated. Further, variations in E. coli appeared to be more commonly correlated to antecedent climate, while total suspended solids were more highly correlated to rainfall/runoff characteristics. This emphasizes the importance of climate on microbial persistence and die off in urban systems. Discrete intra-event concentrations of total suspended solids and, to a lesser extent E. coli, were correlated to flow, velocity, and rainfall intensity (adjusted by time of concentrations). Concentration changes were found to be best described by adjusted rainfall intensity, as shown by other researchers. This study has resulted in an increased understanding of the magnitude of intra-event variations of total suspended solids and E. coli and what physical and climatic parameters influence these variations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Downscaling Solar Power Output to 4-Seconds for Use in Integration Studies (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hummon, M.; Weekley, A.; Searight, K.

    2013-10-01

    High penetration renewable integration studies require solar power data with high spatial and temporal accuracy to quantify the impact of high frequency solar power ramps on the operation of the system. Our previous work concentrated on downscaling solar power from one hour to one minute by simulation. This method used clearness classifications to categorize temporal and spatial variability, and iterative methods to simulate intra-hour clearness variability. We determined that solar power ramp correlations between sites decrease with distance and the duration of the ramp, starting at around 0.6 for 30-minute ramps between sites that are less than 20 km apart.more » The sub-hour irradiance algorithm we developed has a noise floor that causes the correlations to approach ~0.005. Below one minute, the majority of the correlations of solar power ramps between sites less than 20 km apart are zero, and thus a new method to simulate intra-minute variability is needed. These intra-minute solar power ramps can be simulated using several methods, three of which we evaluate: a cubic spline fit to the one-minute solar power data; projection of the power spectral density toward the higher frequency domain; and average high frequency power spectral density from measured data. Each of these methods either under- or over-estimates the variability of intra-minute solar power ramps. We show that an optimized weighted linear sum of methods, dependent on the classification of temporal variability of the segment of one-minute solar power data, yields time series and ramp distributions similar to measured high-resolution solar irradiance data.« less

  10. Downscaling Solar Power Output to 4-Seconds for Use in Integration Studies: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hummon, M.; Weekley, A.; Searight, K.

    2013-10-01

    High penetration renewable integration studies require solar power data with high spatial and temporal accuracy to quantify the impact of high frequency solar power ramps on the operation of the system. Our previous work concentrated on downscaling solar power from one hour to one minute by simulation. This method used clearness classifications to categorize temporal and spatial variability, and iterative methods to simulate intra-hour clearness variability. We determined that solar power ramp correlations between sites decrease with distance and the duration of the ramp, starting at around 0.6 for 30-minute ramps between sites that are less than 20 km apart.more » The sub-hour irradiance algorithm we developed has a noise floor that causes the correlations to approach ~0.005. Below one minute, the majority of the correlations of solar power ramps between sites less than 20 km apart are zero, and thus a new method to simulate intra-minute variability is needed. These intra-minute solar power ramps can be simulated using several methods, three of which we evaluate: a cubic spline fit to the one-minute solar power data; projection of the power spectral density toward the higher frequency domain; and average high frequency power spectral density from measured data. Each of these methods either under- or over-estimates the variability of intra-minute solar power ramps. We show that an optimized weighted linear sum of methods, dependent on the classification of temporal variability of the segment of one-minute solar power data, yields time series and ramp distributions similar to measured high-resolution solar irradiance data.« less

  11. Reproducibility of telomere length assessment: an international collaborative study.

    PubMed

    Martin-Ruiz, Carmen M; Baird, Duncan; Roger, Laureline; Boukamp, Petra; Krunic, Damir; Cawthon, Richard; Dokter, Martin M; van der Harst, Pim; Bekaert, Sofie; de Meyer, Tim; Roos, Goran; Svenson, Ulrika; Codd, Veryan; Samani, Nilesh J; McGlynn, Liane; Shiels, Paul G; Pooley, Karen A; Dunning, Alison M; Cooper, Rachel; Wong, Andrew; Kingston, Andrew; von Zglinicki, Thomas

    2015-10-01

    Telomere length is a putative biomarker of ageing, morbidity and mortality. Its application is hampered by lack of widely applicable reference ranges and uncertainty regarding the present limits of measurement reproducibility within and between laboratories. We instigated an international collaborative study of telomere length assessment: 10 different laboratories, employing 3 different techniques [Southern blotting, single telomere length analysis (STELA) and real-time quantitative PCR (qPCR)] performed two rounds of fully blinded measurements on 10 human DNA samples per round to enable unbiased assessment of intra- and inter-batch variation between laboratories and techniques. Absolute results from different laboratories differed widely and could thus not be compared directly, but rankings of relative telomere lengths were highly correlated (correlation coefficients of 0.63-0.99). Intra-technique correlations were similar for Southern blotting and qPCR and were stronger than inter-technique ones. However, inter-laboratory coefficients of variation (CVs) averaged about 10% for Southern blotting and STELA and more than 20% for qPCR. This difference was compensated for by a higher dynamic range for the qPCR method as shown by equal variance after z-scoring. Technical variation per laboratory, measured as median of intra- and inter-batch CVs, ranged from 1.4% to 9.5%, with differences between laboratories only marginally significant (P = 0.06). Gel-based and PCR-based techniques were not different in accuracy. Intra- and inter-laboratory technical variation severely limits the usefulness of data pooling and excludes sharing of reference ranges between laboratories. We propose to establish a common set of physical telomere length standards to improve comparability of telomere length estimates between laboratories. © The Author 2014. Published by Oxford University Press on behalf of the International Epidemiological Association.

  12. Automation of immunohistochemical evaluation in breast cancer using image analysis

    PubMed Central

    Prasad, Keerthana; Tiwari, Avani; Ilanthodi, Sandhya; Prabhu, Gopalakrishna; Pai, Muktha

    2011-01-01

    AIM: To automate breast cancer diagnosis and to study the inter-observer and intra-observer variations in the manual evaluations. METHODS: Breast tissue specimens from sixty cases were stained separately for estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor-2 (HER-2/neu). All cases were assessed by manual grading as well as image analysis. The manual grading was performed by an experienced expert pathologist. To study inter-observer and intra-observer variations, we obtained readings from another pathologist as the second observer from a different laboratory who has a little less experience than the first observer. We also took a second reading from the second observer to study intra-observer variations. Image analysis was carried out using in-house developed software (TissueQuant). A comparison of the results from image analysis and manual scoring of ER, PR and HER-2/neu was also carried out. RESULTS: The performance of the automated analysis in the case of ER, PR and HER-2/neu expressions was compared with the manual evaluations. The performance of the automated system was found to correlate well with the manual evaluations. The inter-observer variations were measured using Spearman correlation coefficient r and 95% confidence interval. In the case of ER expression, Spearman correlation r = 0.53, in the case of PR expression, r = 0.63, and in the case of HER-2/neu expression, r = 0.68. Similarly, intra-observer variations were also measured. In the case of ER, PR and HER-2/neu expressions, r = 0.46, 0.66 and 0.70, respectively. CONCLUSION: The automation of breast cancer diagnosis from immunohistochemically stained specimens is very useful for providing objective and repeatable evaluations. PMID:21611095

  13. "Friending" Vygotsky: A Social Constructivist Pedagogy of Knowledge Building through Classroom Social Media Use

    ERIC Educational Resources Information Center

    Churcher, Kalen M. A.; Downs, Edward; Tewksbury, Doug

    2014-01-01

    Social media and web 2.0 technologies are an attractive supplement to the higher education experience and are embraced as a way to foster intra-and extracurricular knowledge generation among a class community. However, these collaborative media require a rethinking of the theoretical framework through which we engage student communities of…

  14. Satellite provided customer premise services: A forecast of potential domestic demand through the year 2000. Volume 3: Appendices

    NASA Technical Reports Server (NTRS)

    Kratochvil, D.; Bowyer, J.; Bhushan, C.; Steinnagel, K.; Kaushal, D.; Al-Kinani, G.

    1983-01-01

    Voice applications, data applications, video applications, impacted baseline forecasts, market distribution, potential CPS (customers premises services) user classes, net long haul forecasts, CPS cost analysis, overall satellite forecast, CPS satellite market, Ka-band CPS satellite forecast, nationwide traffic distribution model, and intra-urban topology are discussed.

  15. Teaching Methods for Modelling Problems and Students' Task-Specific Enjoyment, Value, Interest and Self-Efficacy Expectations

    ERIC Educational Resources Information Center

    Schukajlow, Stanislaw; Leiss, Dominik; Pekrun, Reinhard; Blum, Werner; Muller, Marcel; Messner, Rudolf

    2012-01-01

    In this study which was part of the DISUM-project, 224 ninth graders from 14 German classes from middle track schools (Realschule) were asked about their enjoyment, interest, value and self-efficacy expectations concerning three types of mathematical problems: intra-mathematical problems, word problems and modelling problems. Enjoyment, interest,…

  16. Satellite provided customer premise services: A forecast of potential domestic demand through the year 2000. Volume 3: Appendices

    NASA Astrophysics Data System (ADS)

    Kratochvil, D.; Bowyer, J.; Bhushan, C.; Steinnagel, K.; Kaushal, D.; Al-Kinani, G.

    1983-08-01

    Voice applications, data applications, video applications, impacted baseline forecasts, market distribution, potential CPS (customers premises services) user classes, net long haul forecasts, CPS cost analysis, overall satellite forecast, CPS satellite market, Ka-band CPS satellite forecast, nationwide traffic distribution model, and intra-urban topology are discussed.

  17. Influence of deep defects on device performance of thin-film polycrystalline silicon solar cells

    NASA Astrophysics Data System (ADS)

    Fehr, M.; Simon, P.; Sontheimer, T.; Leendertz, C.; Gorka, B.; Schnegg, A.; Rech, B.; Lips, K.

    2012-09-01

    Employing quantitative electron-paramagnetic resonance analysis and numerical simulations, we investigate the performance of thin-film polycrystalline silicon solar cells as a function of defect density. We find that the open-circuit voltage is correlated to the density of defects, which we assign to coordination defects at grain boundaries and in dislocation cores. Numerical device simulations confirm the observed correlation and indicate that the device performance is limited by deep defects in the absorber bulk. Analyzing the defect density as a function of grain size indicates a high concentration of intra-grain defects. For large grains (>2 μm), we find that intra-grain defects dominate over grain boundary defects and limit the solar cell performance.

  18. Predictive value of synovial fluid analysis in estimating the efficacy of intra-articular corticosteroid injections in patients with rheumatoid arthritis.

    PubMed Central

    Luukkainen, R; Hakala, M; Sajanti, E; Huhtala, H; Yli-Kerttula, U; Hämeenkorpi, R

    1992-01-01

    The predictive relevance of synovial fluid analysis and some other variables for the efficacy of intra-articular corticosteroid injections in 30 patients with rheumatoid arthritis and hydropsy in a knee joint was evaluated in a prospective study. At the onset of the study, the knee joints were aspirated and 30 mg triamcinolone hexacetonide injected intra-articularly. The circumferences and the tenderness scores of the knee joints were measured at onset, after two months, and at the end of the six months' follow up. Of the variables studied, synovial fluid C4, percentage of synovial fluid polymorphonuclear leucocytes, blood haemoglobin, and serum C3 correlated significantly with the decrease in knee joint circumference after two months, whereas only the percentage of synovial fluid polymorphonuclear leucocytes correlated significantly after six months. Between the patients with and without improvement in the tenderness scores of the knee joints, only serum IgM differed at the examination after two months; this was higher in patients whose scores showed no improvement. PMID:1632661

  19. Assessment of higher order correlation effects with the help of Moller-Plesset perturbation theory up to sixth order

    NASA Astrophysics Data System (ADS)

    He, Yuan; Cremer, Dieter

    For 30 molecules and two atoms, MP n correlation energies up to n = 6 are computed and used to analyse higher order correlation effects and the initial convergence behaviour of the MP n series. Particularly useful is the analysis of correlation contributions E(n)XY ...( n = 4,5,6; X , Y ,... = S, D, T, Q denoting single, double, triple, and quadruple excitations) in the form of correlation energy spectra. Two classes of system are distinguished, namely class A systems possessing well separated electron pairs and class B systems which are characterized by electron clustering in certain regions of atomic and molecular space. For class A systems, electron pair correlation effects as described by D, Q, DD, DQ, QQ, DDD, etc., contributions are most important, which are stepwise included at MP n with n = 2,... ,6. Class A systems are reasonably described by MP n theory, which is reflected by the fact that convergence of the MP n series is monotonic (but relatively slow) for class A systems. The description of class B systems is difficult since three- and four-electron correlation effects and couplings between two-, three-, and four-electron correlation effects missing for lower order perturbation theory are significant. MP n methods, which do not cover these effects, simulate higher order with lower order correlation effects thus exaggerating the latter, which has to be corrected with increasing n. Consequently, the MP n series oscillates for class B systems at low orders. A possible divergence of the MP n series is mostly a consequence of an unbalanced basis set. For example, diffuse functions added to an unsaturated sp basis lead to an exaggeration of higher order correlation effects, which can cause enhanced oscillations and divergence of the MP n series.

  20. Ultrasound imaging for the rheumatologist XXX. Sonographic assessment of the painful knee.

    PubMed

    Meenagh, G; Filippucci, E; Delle Sedie, A; Iagnocco, A; Scirè, C A; Riente, L; Montecucco, C; Valesini, G; Bombardieri, S; Grassi, W

    2010-01-01

    The knee joint is a frequent focus of attention for rheumatologists when assessing patients presenting to a clinic and may represent underlying intra-articular inflammatory pathology or involvement of the surrounding soft tissues. This study describes the correlation between clinical and ultrasound findings in patients presenting with a variety of rheumatic disorders and knee pain. US imaging provides for a sensitive and detailed identification of different intra- and peri-articular pathology responsible for knee pain.

  1. The Effect of Error Correlation on Interfactor Correlation in Psychometric Measurement

    ERIC Educational Resources Information Center

    Westfall, Peter H.; Henning, Kevin S. S.; Howell, Roy D.

    2012-01-01

    This article shows how interfactor correlation is affected by error correlations. Theoretical and practical justifications for error correlations are given, and a new equivalence class of models is presented to explain the relationship between interfactor correlation and error correlations. The class allows simple, parsimonious modeling of error…

  2. Preliminary evidence for good psychometric properties of the Norwegian version of the Brief Problems Monitor (BPM).

    PubMed

    Richter, Jörg

    2015-04-01

    Methods to assess intervention progress and outcome for frequent use are needed. To provide preliminary information about psychometric properties for the Norwegian version of the Brief Problems Monitor. Cronbach's alpha scores and intra-class correlation coefficients as indicators for internal consistency (reliability) and Pearson correlation coefficients between corresponding subscales of the long and short ASEBA form versions as well as multiple regression coefficients to explore the predictive power of the reduced item-set related to the corresponding scale-scores of the long version were calculated in large, representative data sets of Norwegian children and adolescents. Cronbach's alpha scores of the Norwegian version of the BPM subscales varied between 0.67 (attention BPM-youth) and 0.88 (attention BPM-teacher) and between 0.90 (BPM-youth) and 0.96 (BPM-teacher) for its total problem score. Corresponding subscales from the long versions and the BPM as well as the total problems scores were closely correlated with coefficients of high effect size (all r > 0.80). The variance of the items of the BPM explained about three-quarters or more of the variance in the corresponding subscales of the long version. The Norwegian BPM has good psychometric properties in terms of 1) being acceptable to good internal consistency and in terms of 2) regression coefficients of high effect size from the BPM items to the problem-scale scores of the long versions as validity indicators. Its use in clinical practice and research can be recommended.

  3. Cigarette dependence questionnaire: development and psychometric testing with male smokers.

    PubMed

    Huang, Chih-Ling; Lin, Hsi-Hui; Wang, Hsiu-Hung

    2010-10-01

    This paper is a report of a study conducted to develop and test a theoretically derived Cigarette Dependence Questionnaire for adult male smokers. Fagerstrom questionnaires have been used worldwide to assess cigarette dependence. However, these assessments lack any theoretical perspective. A theory-based approach is needed to ensure valid assessment. In 2007, an initial pool of 103 Cigarette Dependence Questionnaire items was distributed to 109 adult smokers in Taiwan. Item analysis was conducted to select items for inclusion in the refined scale. The psychometric properties of the Cigarette Dependence Questionnaire were further evaluated 2007-08, when it was administered to 256 respondents and their saliva was collected and analysed for cotinine levels. Criterion validity was established through the Pearson correlation between the scale and saliva cotinine levels. Exploratory factor analysis was used to test construct validity. Reliability was determined with Cronbach's alpha coefficient and a 2-week test-retest coefficient. The selection of 30 items for seven perspectives was based on item analysis. One factor accounting for 44.9% of the variance emerged from the factor analysis. The factor was named as cigarette dependence. Cigarette Dependence Questionnaire scores were statistically significantly correlated with saliva cotinine levels (r = 0.21, P = 0.01). Cronbach's alpha was 0.95 and test-retest reliability using an intra-class correlation was 0.92. The Cigarette Dependence Questionnaire showed sound reliability and validity and could be used by nurses to set up smoking cessation interventions based on assessment of cigarette dependence. © 2010 Blackwell Publishing Ltd.

  4. [Validity of self-reported metabolic syndrome components in a cohort study].

    PubMed

    Fernández-Montero, Alejandro; Beunza, Juan J; Bes-Rastrollo, Maira; Barrio, María T; de la Fuente-Arrillaga, Carmen; Moreno-Galarraga, Laura; Martínez-González, Miguel A

    2011-01-01

    To assess the accuracy of self-reported data needed to constitute the metabolic syndrome in the University of Navarra Follow-Up [Seguimiento Universidad de Navarra (SUN)] cohort. The SUN project is a multi-purpose prospective cohort, formed by more than 20,000 university graduates, followed-up using surface mail questionnaires every 2 years. In a sample of 287 cohort participants, self-reported data on the criteria needed to define the metabolic syndrome (waist circumference, blood pressure, triglycerides, high-density lipoprotein-cholesterol and glucose) were compared with the same biometric data obtained by blood tests or measured by trained medical staff. Intra-class correlation coefficients with 95% confidence intervals (95% CI), relative mean error and agreement limits according to the method proposed by Bland and Altman were calculated for each variable studied. High intraclass correlations were found for the values of waist circumference (r=0.86, 95% CI: 0.80-0.90) and triglycerides (r=0.71, 95%CI: 0.61-0.79). Moderate intraclass correlations were found (between 0.46 and 0.63) for the other factors. Relative mean errors were always<2.5%, and >91% of values were within the limits of agreement for all variables. The results suggest that self-declared data on the criteria of metabolic syndrome obtained in the SUN cohort, though with some caution, are sufficiently accurate to be used in epidemiological studies. Copyright © 2010 SESPAS. Published by Elsevier Espana. All rights reserved.

  5. The relationship between vertical jump power estimates and weightlifting ability: a field-test approach.

    PubMed

    Carlock, Jon M; Smith, Sarah L; Hartman, Michael J; Morris, Robert T; Ciroslan, Dragomir A; Pierce, Kyle C; Newton, Robert U; Harman, Everett A; Sands, William A; Stone, Michael H

    2004-08-01

    The purpose of this study was to assess the usefulness of the vertical jump and estimated vertical-jump power as a field test for weightlifting. Estimated PP output from the vertical jump was correlated with lifting ability among 64 USA national-level weightlifters (junior and senior men and women). Vertical jump was measured using the Kinematic Measurement System, consisting of a switch mat interfaced with a laptop computer. Vertical jumps were measured using a hands-on-hips method. A counter-movement vertical jump (CMJ) and a static vertical jump (SJ, 90 degrees knee angle) were measured. Two trials were given for each condition. Test-retest reliability for jump height was intra-class correlation (ICC) = 0.98 (CMJ) and ICC = 0.96 (SJ). Athletes warmed up on their own for 2-3 minutes, followed by 2 practice jumps at each condition. Peak power (PP) was estimated using the equations developed by Sayers et al. (24). The athletes' current lifting capabilities were assessed by a questionnaire, and USA national coaches checked the listed values. Differences between groups (i.e., men versus women, juniors versus resident lifters) were determined using t-tests (p < or = 0.05). Correlations were determined using Pearson's r. Results indicate that vertical jumping PP is strongly associated with weightlifting ability. Thus, these results indicate that PP derived from the vertical jump (CMJ or SJ) can be a valuable tool in assessing weightlifting performance.

  6. Validity and Reliability of Thai Version of the Foot and Ankle Ability Measure (FAAM) Subjective Form.

    PubMed

    Arunakul, Marut; Arunakul, Preeyaphan; Suesiritumrong, Chakhrist; Angthong, Chayanin; Chernchujit, Bancha

    2015-06-01

    Self-administered questionnaires have become an important aspect for clinical outcome assessment of foot and ankle-related problems. The Foot and Ankle Ability Measure (FAAM) subjective form is a region-specific questionnaire that is widely used and has sufficient validity and reliability from previous studies. Translate the original English version of FAAM into a Thai version and evaluate the validity and reliability of Thai FAAM in patients with foot and ankle-related problems. The FAAM subjective form was translated into Thai using forward-backward translation protocol. Afterward, reliability and validity were tested. Following responses from 60 consecutive patients on two questionnaires, the Thai FAAM subjective form and the short form (SF)-36, were used. The validity was tested by correlating the scores from both questionnaires. The reliability was adopted by measuring the test-retest reliability and internal consistency. Thai FAAM score including activity of daily life (ADL) and Sport subscale demonstrated the sufficient correlations with physical functioning (PF) and physical composite score (PCS) domains of the SF-36 (statistically significant with p < 0.001 level and ≥ 0.5 values). The result of reliability revealed highly intra-class correlation coefficient as 0.8 and 0.77, respectively from test-retest study. The internal consistency was strong (Cronbach alpha = 0.94 and 0.88, respectively). The Thai version of FAAM subjective form retained the characteristics of the original version and has proved a reliable evaluation instrument for patients with foot and ankle-related problems.

  7. Determination of heart rate variability with an electronic stethoscope.

    PubMed

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  8. Cross-cultural adaptation and validation of the Peripheral Artery Questionnaire: Korean version for patients with peripheral vascular diseases.

    PubMed

    Lee, Ji Hyun; Cho, Kyoung Im; Spertus, John; Kim, Seong Man

    2012-08-01

    The Peripheral Artery Questionnaire (PAQ), as developed in US English, is a validated scale to evaluate the health status of patients with peripheral artery disease (PAD). The aim of this study was to translate the PAQ into Korean and to evaluate its reliability and validity. A multi-step process of forward-translation, reconciliation, consultation with the developer, back-translation and proofreading was conducted. The test-retest reliability was evaluated at a 2-week interval using the intra-class correlation coefficient (ICC). The validity was assessed by identifying associations between Korean PAQ (KPAQ) scores and Korean Health Assessment Questionnaire (KHAQ) scores. A total of 100 PAD patients were enrolled: 63 without and 37 with severe claudication. The reliability of the KPAQ was adequate, with an ICC of 0.71. There were strong correlations between KPAQ's subscales. Cronbach's alpha for the summary score was 0.94, indicating good internal consistency and congruence with the original US version. The validity was supported by a significant correlation between the total KHAQ score and KPAQ physical function, stability, symptom, social limitation and quality of life scores (r = -0.24 to -0.90; p < 0.001) as well as between the KHAQ walking subscale and the KPAQ physical function score (r = -0.55, p < 0.001). Our results indicate that the KPAQ is a reliable, valid instrument to evaluate the health status of Korean patients with PAD.

  9. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    PubMed

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, p<0.05), and better balance was associated with younger participants in their non-dominant leg (R 2 =0.28, p<0.05) and their dominant leg (R 2 =0.39, p<0.05), and a higher number of hours spent training for the non-dominant leg R 2 =0.37, p<0.05). The multiple single-leg hop-stabilisation test demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  10. In-Depth Characterization of Protein Disulfide Bonds by Online Liquid Chromatography-Electrochemistry-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Switzar, Linda; Nicolardi, Simone; Rutten, Julie W.; Oberstein, Saskia A. J. Lesnik; Aartsma-Rus, Annemieke; van der Burgt, Yuri E. M.

    2016-01-01

    Disulfide bonds are an important class of protein post-translational modifications, yet this structurally crucial modification type is commonly overlooked in mass spectrometry (MS)-based proteomics approaches. Recently, the benefits of online electrochemistry-assisted reduction of protein S-S bonds prior to MS analysis were exemplified by successful characterization of disulfide bonds in peptides and small proteins. In the current study, we have combined liquid chromatography (LC) with electrochemistry (EC) and mass analysis by Fourier transform ion cyclotron resonance (FTICR) MS in an online LC-EC-MS platform to characterize protein disulfide bonds in a bottom-up proteomics workflow. A key advantage of a LC-based strategy is the use of the retention time in identifying both intra- and interpeptide disulfide bonds. This is demonstrated by performing two sequential analyses of a certain protein digest, once without and once with electrochemical reduction. In this way, the "parent" disulfide-linked peptide detected in the first run has a retention time-based correlation with the EC-reduced peptides detected in the second run, thus simplifying disulfide bond mapping. Using this platform, both inter- and intra-disulfide-linked peptides were characterized in two different proteins, ß-lactoglobulin and ribonuclease B. In order to prevent disulfide reshuffling during the digestion process, proteins were digested at a relatively low pH, using (a combination of) the high specificity proteases trypsin and Glu-C. With this approach, disulfide bonds in ß-lactoglobulin and ribonuclease B were comprehensively identified and localized, showing that online LC-EC-MS is a useful tool for the characterization of protein disulfide bonds.

  11. Genomic Characterization of USA300 Methicillin-Resistant Staphylococcus aureus (MRSA) to Evaluate Intraclass Transmission and Recurrence of Skin and Soft Tissue Infection (SSTI) Among High-Risk Military Trainees.

    PubMed

    Millar, Eugene V; Rice, Gregory K; Elassal, Emad M; Schlett, Carey D; Bennett, Jason W; Redden, Cassie L; Mor, Deepika; Law, Natasha N; Tribble, David R; Hamilton, Theron; Ellis, Michael W; Bishop-Lilly, Kimberly A

    2017-08-01

    Military trainees are at increased risk for methicillin-resistant Staphylococcus aureus (MRSA) skin and soft tissue infection (SSTI). Whole genome sequencing (WGS) can refine our understanding of MRSA transmission and microevolution in congregate settings. We conducted a prospective case-control study of SSTI among US Army infantry trainees at Fort Benning, Georgia, from July 2012 to December 2014. We identified clusters of USA300 MRSA SSTI within select training classes and performed WGS on clinical isolates. We then linked genomic, phylogenetic, epidemiologic, and clinical data in order to evaluate intra- and interclass disease transmission. Furthermore, among cases of recurrent MRSA SSTI, we evaluated the intrahost relatedness of infecting strains. Nine training classes with ≥5 cases of USA300 MRSA SSTI were selected. Eighty USA300 MRSA clinical isolates from 74 trainees, 6 (8.1%) of whom had recurrent infection, were subjected to WGS. We identified 2719 single nucleotide variants (SNVs). The overall median (range) SNV difference between isolates was 173 (1-339). Intraclass median SNV differences ranged from 23 to 245. Two phylogenetic clusters were suggestive of interclass MRSA transmission. One of these clusters stemmed from 2 classes that were separated by a 13-month period but housed in the same barracks. Among trainees with recurrent MRSA SSTI, the intrahost median SNV difference was 7.5 (1-48). Application of WGS revealed intra- and interclass transmission of MRSA among military trainees. An interclass cluster between 2 noncontemporaneous classes suggests a long-term reservoir for MRSA in this setting. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  12. Object Classification With Joint Projection and Low-Rank Dictionary Learning.

    PubMed

    Foroughi, Homa; Ray, Nilanjan; Hong Zhang

    2018-02-01

    For an object classification system, the most critical obstacles toward real-world applications are often caused by large intra-class variability, arising from different lightings, occlusion, and corruption, in limited sample sets. Most methods in the literature would fail when the training samples are heavily occluded, corrupted or have significant illumination or viewpoint variations. Besides, most of the existing methods and especially deep learning-based methods, need large training sets to achieve a satisfactory recognition performance. Although using the pre-trained network on a generic large-scale data set and fine-tune it to the small-sized target data set is a widely used technique, this would not help when the content of base and target data sets are very different. To address these issues simultaneously, we propose a joint projection and low-rank dictionary learning method using dual graph constraints. Specifically, a structured class-specific dictionary is learned in the low-dimensional space, and the discrimination is further improved by imposing a graph constraint on the coding coefficients, that maximizes the intra-class compactness and inter-class separability. We enforce structural incoherence and low-rank constraints on sub-dictionaries to reduce the redundancy among them, and also make them robust to variations and outliers. To preserve the intrinsic structure of data, we introduce a supervised neighborhood graph into the framework to make the proposed method robust to small-sized and high-dimensional data sets. Experimental results on several benchmark data sets verify the superior performance of our method for object classification of small-sized data sets, which include a considerable amount of different kinds of variation, and may have high-dimensional feature vectors.

  13. Maxillary protraction in adult cleft lip and palate by a rigid external distraction device with dentoskeletal anchorage.

    PubMed

    Akarsu, Bengisu; Taner, Tulin; Tuncbilek, Gokhan; Mavili, M Emin

    2012-04-01

    The objective is to evaluate the effects of maxillary distraction osteogenesis (DO) in an adult patient with unilateral cleft lip and palate (UCLP) by using a rigid external distraction (RED) device with dentoskeletal anchorage. 31-year-old male patient with UCLP with severe maxillary hypoplasia, dolichofacial growth pattern, negative overjet and 1.5 mm openbite. After pre-surgical orthodontic treatment, an intra-oral appliance was modified to prevent extrusion of the molars and clockwise rotation of the mandible. Stainless steel plates were soldered bilaterally to the intra oral appliance at the level of canines. During surgery, miniplates were inserted in the maxillary segment and fixed to the plates of the intra oral appliance with screws. The mean distraction length was 12 mm immediately after DO. SNA increased from 73o to 82o after distraction. A significant advancement of the maxilla and correction of the sagittal Class III skeletal relationship was achieved. The vertical position of the mandible and the face was kept stable, and the soft tissue profile became more balanced. This intra oral appliance design achieved desired skeletal changes during maxillary protraction with RED device in dolichofacial CLP patient. Occlusion and facial profile changes was found to be stable in 1-year follow-up.

  14. Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board.

    PubMed

    Quek, June; Treleaven, Julia; Brauer, Sandra G; O'Leary, Shaun; Clark, Ross A

    2015-01-01

    The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Thirty healthy individuals (age: 34.9 ± 12.9 years, height: 170.4 ± 10.5 cm, weight: 69.3 ± 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.

  15. Maxillary protraction in adult cleft lip and palate by a rigid external distraction device with dentoskeletal anchorage

    PubMed Central

    Akarsu, Bengisu; Taner, Tulin; Tuncbilek, Gokhan; Mavili, M. Emin

    2012-01-01

    Objective: The objective is to evaluate the effects of maxillary distraction osteogenesis (DO) in an adult patient with unilateral cleft lip and palate (UCLP) by using a rigid external distraction (RED) device with dentoskeletal anchorage. Method: 31-year-old male patient with UCLP with severe maxillary hypoplasia, dolichofacial growth pattern, negative overjet and 1.5 mm openbite. After pre-surgical orthodontic treatment, an intra-oral appliance was modified to prevent extrusion of the molars and clockwise rotation of the mandible. Stainless steel plates were soldered bilaterally to the intra oral appliance at the level of canines. During surgery, miniplates were inserted in the maxillary segment and fixed to the plates of the intra oral appliance with screws. Results: The mean distraction length was 12 mm immediately after DO. SNA increased from 73o to 82o after distraction. A significant advancement of the maxilla and correction of the sagittal Class III skeletal relationship was achieved. The vertical position of the mandible and the face was kept stable, and the soft tissue profile became more balanced. Conclusion: This intra oral appliance design achieved desired skeletal changes during maxillary protraction with RED device in dolichofacial CLP patient. Occlusion and facial profile changes was found to be stable in 1-year follow-up. PMID:22509125

  16. Inter- and intra-observer reliability of measurement of pedicle screw breach assessed by postoperative CT scans.

    PubMed

    Lavelle, William F; Ranade, Ashish; Samdani, Amer F; Gaughan, John P; D'Andrea, Linda P; Betz, Randal R

    2014-01-01

    Pedicle screws are used increasingly in spine surgery. Concerns of complications associated with screw breach necessitates accurate pedicle screw placement. Postoperative CT imaging helps to detect screw malposition and assess its severity. However, accuracy is dependent on the reading of the CT scans. Inter- and intra-observer variability could affect the reliability of CT scans to assess multiple screw types and sites. The purpose of this study was to assess the reliability of multi-observer analysis of CT scans for determining pedicle screw breach for various screw types and sites in patients with spinal deformity or degenerative pathologies. Axial CT scan images of 23 patients (286 screws) were read by four experienced spine surgeons. Pedicle screw placement was considered 'In' when the screw was fully contained and/or the pedicle wall breach was ≤2 mm. 'Out' was defined as a breach in the medial or lateral pedicle wall >2 mm. Intra-class coefficients (ICC) were calculated to assess the inter- and intra-observer reliability. Marked inter- and intra-observer variability was noticed. The overall inter-observer ICC was 0.45 (95% confidence limits 0.25 to 0.65). The intra-observer ICC was 0.49 (95% confidence limits 0.29 to 0.69). Underlying spinal pathology, screw type, and patient age did not seem to impact the reliability of our CT assessments. Our results indicate the evaluation of pedicle screw breach on CT by a single surgeon is highly variable, and care should be taken when using individual CT evaluations of millimeters of breach as a basis for screw removal. This was a Level III study.

  17. Intra-specific competition (crowding) of giant sequoias (Sequoiadendron giganteum)

    USGS Publications Warehouse

    Stohlgren, Thomas J.

    1993-01-01

    Information on the size and location of 1916 giant sequoias (Sequoiadendron giganteum (Lindl.) Buchholz) in Muir Grove, Sequoia National Park, in the southern Sierra Nevada of California was used to assess intra-specific crowding. Study objectives were to: (1) determine which parameters associated with intra-specific competition (i.e. size and distance to nearest neighbor, crowding/root system area overlap, or number of neighbors) might be important in spatial pattern development, growth, and survivorship of established giant sequoias; (2) quantify the level of intra-specific crowding of different sized live sequoias based on a model of estimated overlapping root system areas (i.e. an index of relative crowding); (3) compare the level of intra-specific crowding of similarly sized live and dead giant sequoias (less than 30 cm diameter at breast height (dbh) at the time of inventory (1969). Mean distances to the nearest live giant sequoia neighbor were not significantly different (at α = 0.05) for live and dead sequoias in similar size classes. A zone of influence competition model (i.e. index of crowding) based on horizontal overlap of estimated root system areas was developed for 1753 live sequoias. The model, based only on the spatial arrangement of live sequoias, was then tested on dead sequoias of less than 30 cm dbh (n = 163 trees; also recorded in 1969). The dead sequoias had a significantly higher crowding index than 561 live trees of similar diameter. Results showed that dead sequoias of less than 16.6 cm dbh had a significantly greater mean number of live neighbors and mean crowding index than live sequoias of similar size. Intra-specific crowding may be an important mechanism in determining the spatial distribution of sequoias in old-growth forests.

  18. Intra-individual variation of plasma trimethylamine-N-oxide (TMAO), betaine and choline over 1 year.

    PubMed

    Kühn, Tilman; Rohrmann, Sabine; Sookthai, Disorn; Johnson, Theron; Katzke, Verena; Kaaks, Rudolf; von Eckardstein, Arnold; Müller, Daniel

    2017-02-01

    Circulating trimethylamine-N-oxide (TMAO) has been implicated in the development of cardiovascular and chronic kidney diseases (CKD). However, while higher TMAO levels have been associated with increased risks of cardiovascular or renal events in first prospective studies, it remained unclear how much plasma TMAO concentrations vary over time. We measured fasting plasma levels of TMAO and two of its precursors, betaine and choline by LC-MS, in two samples of 100 participants of the European Investigation into Cancer and Nutrition (EPIC)-Heidelberg study (age range: 47-80 years, 50% female) that were collected 1 year apart, and assessed their intra-individual variation by Spearman's correlation coefficients (ρ). Correlations of metabolite concentrations over 1 year were at ρ=0.29 (p=0.003) for TMAO, ρ=0.81 (p<0.001) for betaine, and ρ=0.61 (p<0.001) for choline. Plasma levels of TMAO were not significantly associated with food intake, lifestyle factors, or routine biochemistry parameters such as C-reactive protein (CRP), low-density lipoprotein (LDL)-cholesterol, or creatinine. In contrast to fasting plasma concentrations of betaine and choline, concentrations of TMAO were more strongly affected by intra-individual variation over 1 year in adults from the general population. The modest correlation of TMAO levels over time should be considered when interpreting associations between TMAO levels and disease endpoints.

  19. The Lateral Meniscus as a Guide to Anatomical Tibial Tunnel Placement During Anterior Cruciate Ligament Reconstruction.

    PubMed

    Kassam, A M; Tillotson, L; Schranz, P J; Mandalia, V I

    2015-01-01

    The aim of the study is to show, on an MRI scan, that the posterior border of the anterior horn of the lateral meniscus (AHLM) could guide tibial tunnel position in the sagittal plane and provide anatomical graft position. One hundred MRI scans were analysed with normal cruciate ligaments and no evidence of meniscal injury. We measured the distance between the posterior border of the AHLM and the midpoint of the ACL by superimposing sagittal images. The mean distance between the posterior border of the AHLM and the ACL midpoint was -0.1mm (i.e. 0.1mm posterior to the ACL midpoint). The range was 5mm to -4.6mm. The median value was 0.0mm. 95% confidence interval was from -0.5 to 0.3mm. A normal, parametric distribution was observed and Intra- and inter-observer variability showed significant correlation (p<0.05) using Pearsons Correlation test (intra-observer) and Interclass correlation (inter-observer). Using the posterior border of the AHLM is a reproducible and anatomical marker for the midpoint of the ACL footprint in the majority of cases. It can be used intra-operatively as a guide for tibial tunnel insertion and graft placement allowing anatomical reconstruction. There will inevitably be some anatomical variation. Pre-operative MRI assessment of the relationship between AHLM and ACL footprint is advised to improve surgical planning. Level 4.

  20. Trunk Muscle Size and Composition Assessment in Older Adults with Chronic Low Back Pain: An Intra-Examiner and Inter-Examiner Reliability Study.

    PubMed

    Sions, Jaclyn Megan; Smith, Andrew Craig; Hicks, Gregory Evan; Elliott, James Matthew

    2016-08-01

    To evaluate intra- and inter-examiner reliability for the assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area, i.e., total cross-sectional area minus intramuscular fat, from T1-weighted magnetic resonance images obtained in older adults with chronic low back pain. Reliability study. n = 13 (69.3 ± 8.2 years old) After lumbar magnetic resonance imaging, two examiners produced relative cross-sectional area measurements of multifidi, erector spinae, psoas, and quadratus lumborum by tracing regions of interest just inside fascial borders. Pixel-intensity summaries were used to determine muscle-to-fat infiltration indices; relative muscle cross-sectional area was calculated. Intraclass correlation coefficients were used to estimate intra- and inter-examiner reliability; standard error of measurement was calculated. Intra-examiner intraclass correlation coefficient point estimates for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area were excellent for multifidi and erector spinae across levels L2-L5 (ICC = 0.77-0.99). At L3, intra-examiner reliability was excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area for both psoas and quadratus lumborum (ICC = 0.81-0.99). Inter-examiner intraclass correlation coefficients ranged from poor to excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area. Assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area in older adults with chronic low back pain can be reliably determined by one examiner from T1-weighted images. Such assessments provide valuable information, as muscle-to-fat infiltration indices and relative muscle cross-sectional area indicate that a substantial amount of relative cross-sectional area may be magnetic resonance-visible intramuscular fat in older adults with chronic low back pain. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Hyperandrogenism Accompanies Increased Intra-Abdominal Fat Storage in Normal Weight Polycystic Ovary Syndrome Women.

    PubMed

    Dumesic, Daniel A; Akopians, Alin L; Madrigal, Vanessa K; Ramirez, Emmanuel; Margolis, Daniel J; Sarma, Manoj K; Thomas, Albert M; Grogan, Tristan R; Haykal, Rasha; Schooler, Tery A; Okeya, Bette L; Abbott, David H; Chazenbalk, Gregorio D

    2016-11-01

    Normal weight polycystic ovary syndrome (PCOS) women may have altered adipose structure-function underlying metabolic dysfunction. This study examines whether adipose structure-functional changes exist in normal weight PCOS women and correlate with hyperandrogenism and/or hyperinsulinemia. This is a prospective cohort study. The setting was an academic medical center. Six normal weight PCOS women and 14 age- and body mass index-matched normoandrogenic ovulatory (NL) women were included. All women underwent circulating hormone and metabolic measurements; frequently sampled intravenous glucose tolerance testing; total body dual-energy x-ray absorptiometry; abdominal magnetic resonance imaging; and SC abdominal fat biopsy. Circulating hormones and metabolites, body fat and its distribution, and adipocyte size were compared between PCOS and NL women, and were correlated with each other in all women. Circulating LH and androgen levels were significantly greater in PCOS than NL women, as were fasting insulin levels, pancreatic β-cell responsiveness to glucose, and total abdominal fat mass. Intra-abdominal fat mass also was significantly increased in PCOS women and was positively correlated with circulating androgen, fasting insulin, triglyceride, and non-high-density lipoprotein cholesterol levels in all women. SC abdominal fat mass was not significantly increased in PCOS women, but contained a greater proportion of small SC abdominal adipocytes that positively correlated with serum androgen levels in all women. Hyperandrogenism in normal weight PCOS women is associated with preferential intra-abdominal fat deposition and an increased population of small SC abdominal adipocytes that could constrain SC adipose storage and promote metabolic dysfunction.

  2. Is scaffold hopping a reliable indicator for the ability of computational methods to identify structurally diverse active compounds?

    NASA Astrophysics Data System (ADS)

    Dimova, Dilyana; Bajorath, Jürgen

    2017-07-01

    Computational scaffold hopping aims to identify core structure replacements in active compounds. To evaluate scaffold hopping potential from a principal point of view, regardless of the computational methods that are applied, a global analysis of conventional scaffolds in analog series from compound activity classes was carried out. The majority of analog series was found to contain multiple scaffolds, thus enabling the detection of intra-series scaffold hops among closely related compounds. More than 1000 activity classes were found to contain increasing proportions of multi-scaffold analog series. Thus, using such activity classes for scaffold hopping analysis is likely to overestimate the scaffold hopping (core structure replacement) potential of computational methods, due to an abundance of artificial scaffold hops that are possible within analog series.

  3. Intra and inter-rater reliability of infrared image analysis of masticatory and upper trapezius muscles in women with and without temporomandibular disorder.

    PubMed

    Costa, Ana C S; Dibai Filho, Almir V; Packer, Amanda C; Rodrigues-Bigaton, Delaine

    2013-01-01

    Infrared thermography is an aid tool that can be used to evaluate several pathologies given its efficiency in analyzing the distribution of skin surface temperature. To propose two forms of infrared image analysis of the masticatory and upper trapezius muscles, and to determine the intra and inter-rater reliability of both forms of analysis. Infrared images of masticatory and upper trapezius muscles of 64 female volunteers with and without temporomandibular disorder (TMD) were collected. Two raters performed the infrared image analysis, which occurred in two ways: temperature measurement of the muscle length and in central portion of the muscle. The Intraclass Correlation Coefficient (ICC) was used to determine the intra and inter-rater reliability. The ICC showed excellent intra and inter-rater values for both measurements: temperature measurement of the muscle length (TMD group, intra-rater, ICC ranged from 0.996 to 0.999, inter-rater, ICC ranged from 0.992 to 0.999; control group, intra-rater, ICC ranged from 0.993 to 0.998, inter-rater, ICC ranged from 0.990 to 0.998), and temperature measurement of the central portion of the muscle (TMD group, intra-rater, ICC ranged from 0.981 to 0.998, inter-rater, ICC ranged from 0.971 to 0.998; control group, intra-rater, ICC ranged from 0.887 to 0.996, inter-rater, ICC ranged from 0.852 to 0.996). The results indicated that temperature measurements of the masticatory and upper trapezius muscles carried out by the analysis of the muscle length and central portion yielded excellent intra and inter-rater reliability.

  4. Functional connectivity patterns reflect individual differences in conflict adaptation.

    PubMed

    Wang, Xiangpeng; Wang, Ting; Chen, Zhencai; Hitchman, Glenn; Liu, Yijun; Chen, Antao

    2015-04-01

    Individuals differ in the ability to utilize previous conflict information to optimize current conflict resolution, which is termed the conflict adaptation effect. Previous studies have linked individual differences in conflict adaptation to distinct brain regions. However, the network-based neural mechanisms subserving the individual differences of the conflict adaptation effect have not been studied. The present study employed a psychophysiological interaction (PPI) analysis with a color-naming Stroop task to examine this issue. The main results were as follows: (1) the anterior cingulate cortex (ACC)-seeded PPI revealed the involvement of the salience network (SN) in conflict adaptation, while the posterior parietal cortex (PPC)-seeded PPI revealed the engagement of the central executive network (CEN). (2) Participants with high conflict adaptation effect showed higher intra-CEN connectivity and lower intra-SN connectivity; while those with low conflict adaptation effect showed higher intra-SN connectivity and lower intra-CEN connectivity. (3) The PPC-centered intra-CEN connectivity positively predicted the conflict adaptation effect; while the ACC-centered intra-SN connectivity had a negative correlation with this effect. In conclusion, our data demonstrated that conflict adaptation is likely supported by the CEN and the SN, providing a new perspective on studying individual differences in conflict adaptation on the basis of large-scale networks. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Learning Low-Rank Class-Specific Dictionary and Sparse Intra-Class Variant Dictionary for Face Recognition.

    PubMed

    Tang, Xin; Feng, Guo-Can; Li, Xiao-Xin; Cai, Jia-Xin

    2015-01-01

    Face recognition is challenging especially when the images from different persons are similar to each other due to variations in illumination, expression, and occlusion. If we have sufficient training images of each person which can span the facial variations of that person under testing conditions, sparse representation based classification (SRC) achieves very promising results. However, in many applications, face recognition often encounters the small sample size problem arising from the small number of available training images for each person. In this paper, we present a novel face recognition framework by utilizing low-rank and sparse error matrix decomposition, and sparse coding techniques (LRSE+SC). Firstly, the low-rank matrix recovery technique is applied to decompose the face images per class into a low-rank matrix and a sparse error matrix. The low-rank matrix of each individual is a class-specific dictionary and it captures the discriminative feature of this individual. The sparse error matrix represents the intra-class variations, such as illumination, expression changes. Secondly, we combine the low-rank part (representative basis) of each person into a supervised dictionary and integrate all the sparse error matrix of each individual into a within-individual variant dictionary which can be applied to represent the possible variations between the testing and training images. Then these two dictionaries are used to code the query image. The within-individual variant dictionary can be shared by all the subjects and only contribute to explain the lighting conditions, expressions, and occlusions of the query image rather than discrimination. At last, a reconstruction-based scheme is adopted for face recognition. Since the within-individual dictionary is introduced, LRSE+SC can handle the problem of the corrupted training data and the situation that not all subjects have enough samples for training. Experimental results show that our method achieves the state-of-the-art results on AR, FERET, FRGC and LFW databases.

  6. Learning Low-Rank Class-Specific Dictionary and Sparse Intra-Class Variant Dictionary for Face Recognition

    PubMed Central

    Tang, Xin; Feng, Guo-can; Li, Xiao-xin; Cai, Jia-xin

    2015-01-01

    Face recognition is challenging especially when the images from different persons are similar to each other due to variations in illumination, expression, and occlusion. If we have sufficient training images of each person which can span the facial variations of that person under testing conditions, sparse representation based classification (SRC) achieves very promising results. However, in many applications, face recognition often encounters the small sample size problem arising from the small number of available training images for each person. In this paper, we present a novel face recognition framework by utilizing low-rank and sparse error matrix decomposition, and sparse coding techniques (LRSE+SC). Firstly, the low-rank matrix recovery technique is applied to decompose the face images per class into a low-rank matrix and a sparse error matrix. The low-rank matrix of each individual is a class-specific dictionary and it captures the discriminative feature of this individual. The sparse error matrix represents the intra-class variations, such as illumination, expression changes. Secondly, we combine the low-rank part (representative basis) of each person into a supervised dictionary and integrate all the sparse error matrix of each individual into a within-individual variant dictionary which can be applied to represent the possible variations between the testing and training images. Then these two dictionaries are used to code the query image. The within-individual variant dictionary can be shared by all the subjects and only contribute to explain the lighting conditions, expressions, and occlusions of the query image rather than discrimination. At last, a reconstruction-based scheme is adopted for face recognition. Since the within-individual dictionary is introduced, LRSE+SC can handle the problem of the corrupted training data and the situation that not all subjects have enough samples for training. Experimental results show that our method achieves the state-of-the-art results on AR, FERET, FRGC and LFW databases. PMID:26571112

  7. Solidarity and Conflict: Aligned and Misaligned Prosody as a Transactional Resource in Intra- and Intercultural Communication Involving Power Differences

    ERIC Educational Resources Information Center

    Roth, Wolff-Michael; Tobin, Kenneth

    2010-01-01

    This ethnographic study of teaching and learning in urban high school science classes investigates the ways in which teachers and students talk, gesture, and use space and time in interaction rituals. In situations where teachers coteach as a means of learning to teach in inner-city schools, successful teacher-teacher collaborations are…

  8. Detection of Inter- and Intra-Specific Competition in the Insect Communities of British Trees: A Practical Exercise in Community Ecology.

    ERIC Educational Resources Information Center

    Putman, R. J.

    1984-01-01

    Describes an activity (suitable for high school or college) in which the effects of competition in the structuring of ecological communities are examined. The exercise also offers an introduction into species diversity; more advanced classes may be encouraged to seek reasons for differences in insect diversity on different trees. (Author/JN)

  9. S-CNN: Subcategory-aware convolutional networks for object detection.

    PubMed

    Chen, Tao; Lu, Shijian; Fan, Jiayuan

    2017-09-26

    The marriage between the deep convolutional neural network (CNN) and region proposals has made breakthroughs for object detection in recent years. While the discriminative object features are learned via a deep CNN for classification, the large intra-class variation and deformation still limit the performance of the CNN based object detection. We propose a subcategory-aware CNN (S-CNN) to solve the object intra-class variation problem. In the proposed technique, the training samples are first grouped into multiple subcategories automatically through a novel instance sharing maximum margin clustering process. A multi-component Aggregated Channel Feature (ACF) detector is then trained to produce more latent training samples, where each ACF component corresponds to one clustered subcategory. The produced latent samples together with their subcategory labels are further fed into a CNN classifier to filter out false proposals for object detection. An iterative learning algorithm is designed for the joint optimization of image subcategorization, multi-component ACF detector, and subcategory-aware CNN classifier. Experiments on INRIA Person dataset, Pascal VOC 2007 dataset and MS COCO dataset show that the proposed technique clearly outperforms the state-of-the-art methods for generic object detection.

  10. Who Is at Risk for Diagnostic Discrepancies? Comparison of Pre- and Postmortal Diagnoses in 1800 Patients of 3 Medical Decades in East and West Berlin

    PubMed Central

    Wittschieber, Daniel; Klauschen, Frederick; Kimmritz, Anna-Christin; von Winterfeld, Moritz; Kamphues, Carsten; Scholman, Hans-Joachim; Erbersdobler, Andreas; Pfeiffer, Heidi; Denkert, Carsten; Dietel, Manfred; Weichert, Wilko

    2012-01-01

    Background Autopsy rates in Western countries consistently decline to an average of <5%, although clinical autopsies represent a reasonable tool for quality control in hospitals, medically and economically. Comparing pre- and postmortal diagnoses, diagnostic discrepancies as uncovered by clinical autopsies supply crucial information on how to improve clinical treatment. The study aimed at analyzing current diagnostic discrepancy rates, investigating their influencing factors and identifying risk profiles of patients that could be affected by a diagnostic discrepancy. Methods and Findings Of all adult autopsy cases of the Charité Institute of Pathology from the years 1988, 1993, 1998, 2003 and 2008, the pre- and postmortal diagnoses and all demographic data were analyzed retrospectively. Based on power analysis, 1,800 cases were randomly selected to perform discrepancy classification (class I-VI) according to modified Goldman criteria. The rate of discrepancies in major diagnoses (class I) was 10.7% (95% CI: 7.7%–14.7%) in 2008 representing a reduction by 15.1%. Subgroup analysis revealed several influencing factors to significantly correlate with the discrepancy rate. Cardiovascular diseases had the highest frequency among class-I-discrepancies. Comparing the 1988-data of East- and West-Berlin, no significant differences were found in diagnostic discrepancies despite an autopsy rate differing by nearly 50%. A risk profile analysis visualized by intuitive heatmaps revealed a significantly high discrepancy rate in patients treated in low or intermediate care units at community hospitals. In this collective, patients with genitourinary/renal or infectious diseases were at particularly high risk. Conclusions This is the current largest and most comprehensive study on diagnostic discrepancies worldwide. Our well-powered analysis revealed a significant rate of class-I-discrepancies indicating that autopsies are still of value. The identified risk profiles may aid both pathologists and clinicians to identify patients at increased risk for a discrepant diagnosis and possibly suboptimal treatment intra vitam. PMID:22629399

  11. Limited variation in vaccine candidate Plasmodium falciparum Merozoite Surface Protein-6 over multiple transmission seasons.

    PubMed

    Neal, Aaron T; Jordan, Stephen J; Oliveira, Ana L; Hernandez, Jean N; Branch, Oralee H; Rayner, Julian C

    2010-05-24

    Plasmodium falciparum Merozoite Surface Protein-6 (PfMSP6) is a component of the complex proteinacious coat that surrounds P. falciparum merozoites. This location, and the presence of anti-PfMSP6 antibodies in P. falciparum-exposed individuals, makes PfMSP6 a potential blood stage vaccine target. However, genetic diversity has proven to be a major hurdle for vaccines targeting other blood stage P. falciparum antigens, and few endemic field studies assessing PfMSP6 gene diversity have been conducted. This study follows PfMSP6 diversity in the Peruvian Amazon from 2003 to 2006 and is the first longitudinal assessment of PfMSP6 sequence dynamics. Parasite DNA was extracted from 506 distinct P. falciparum infections spanning the transmission seasons from 2003 to 2006 as part of the Malaria Immunology and Genetics in the Amazon (MIGIA) cohort study near Iquitos, Peru. PfMSP6 was amplified from each sample using a nested PCR protocol, genotyped for allele class by agarose gel electrophoresis, and sequenced to detect diversity. Allele frequencies were analysed using JMP v.8.0.1.0 and correlated with clinical and epidemiological data collected as part of the MIGIA project. Both PfMSP6 allele classes, K1-like and 3D7-like, were detected at the study site, confirming that both are globally distributed. Allele frequencies varied significantly between transmission seasons, with 3D7-class alleles dominating and K1-class alleles nearly disappearing in 2005 and 2006. There was a significant association between allele class and village location (p-value = 0.0008), but no statistically significant association between allele class and age, sex, or symptom status. No intra-allele class sequence diversity was detected. Both PfMSP6 allele classes are globally distributed, and this study shows that allele frequencies can fluctuate significantly between communities separated by only a few kilometres, and over time in the same community. By contrast, PfMSP6 was highly stable at the sequence level, with no SNPs detected in the 506 samples analysed. This limited diversity supports further investigation of PfMSP6 as a blood stage vaccine candidate, with the clear caveat that any such vaccine must either contain both alleles or generate cross-protective responses that react against both allele classes. Detailed immunoepidemiology studies are needed to establish the viability of these approaches before PfMSP6 advances further down the vaccine development pipeline.

  12. Pre-clinical validation of a new intra-operative "dual beam Doppler" blood flowmeter in an artificial circuit.

    PubMed

    Cikirikcioglu, Mustafa; Cikirikcioglu, Y Banu; Khabiri, Ebrahim; Djebaili, M Karim; Kalangos, Afksendiyos; Walpoth, Beat H

    2006-01-01

    Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user accuracy test, larger variance changes were observed between intra- and inter-observer results with the dual beam Doppler flowmeter compared to the 2 used transit time flowmeters when used for single sided vessel access without stabilization device (available from the manufacturer). All 3 tested flowmeters showed an excellent correlation to the true flow in an artificial circuit and the accuracy of the tested devices was within agreement limits. Reproducibility of all devices was good and linear. The new dual beam Doppler flow measurement technique compares favorably to the classic transit time method. Clinical use may depend on operator, location, and condition, thus more studies may be required to ensure uniform results using the currently available blood flow measurement devices.

  13. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    PubMed

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  14. Social mobility and health in the Turin longitudinal study.

    PubMed

    Cardano, Mario; Costa, Giuseppe; Demaria, Moreno

    2004-04-01

    One of the most controversial explanations of class inequalities in health is the health selection hypothesis or drift hypothesis which suggests there is a casual link between the health status of individuals and their chances of social mobility, both inter- and intra-generational. This study tests this hypothesis, and tries to answer three related questions: (a) to what extent does health status influence the chances of intra-generational mobility of individuals? (b) what is the impact on health inequalities of the various kinds of social mobility (both mobility in the labour market and exit from employment)-do they increase or reduce inequalities? (c) to what extent does health-related intra-generational social mobility contribute to the production of health inequalities? The data analysed in this paper were drawn from the records of the Turin Longitudinal Study, which was set up to monitor health inequality of the Turin population by combining census data, population registry records and medical records. Occupational mobility was observed during the decade 1981-1991. To evaluate the impact of the various processes of social mobility on health inequalities, mortality was observed over the period 1991-1999. The study population consists of men and women aged 25-49 at the beginning of mortality follow-up (1991), and registered as resident in Turin at both the 1981 and the 1991 censuses (N = 127,384). Health status was determined by observing hospital admission. For the purpose of the study healthy individuals were those with no hospital admissions during the period 1984-1986, while those admitted were classed as unhealthy. Social mobility in the labour market was measured via an interval data index of upward and downward movements on a scale of social desirability of occupations, designed for the Italian labour force via an empirical study carried out by de Lillo and Schizzerotto (La valutazione sociale delle occupazioni. Una scala di stratificazione occupazionale per l'Italia contemporanea, Il Mulino, Bologna, 1985). Movement out of the labour market was described by a discrete variable with four conditions: employed, unemployed, early retired and women returning from work to the housewife status. The relationship between health status and occupational mobility was analysed via analysis of variance and multinomial logistic regression. Health inequalities were measured by the ratio of standardised mortality rates in the unskilled working class and the upper middle class. The study found a weak relationship between health status and occupational mobility chances. Decidedly stronger was the impact on occupational mobility of gender, education and "ethnicity" (being born in the South of Italy). The relationship between occupational mobility and health takes two different forms. Occupational mobility in the labour market decreases health inequalities; occupational mobility out of the labour market (early retirement, unemployment, housewife return) widens them. The maximum contribution health-related intra-generational social mobility can make towards health inequalities was estimated at about 13% for men.

  15. Computer-assisted stereology and automated image analysis for quantification of tumor infiltrating lymphocytes in colon cancer.

    PubMed

    Eriksen, Ann C; Andersen, Johnnie B; Kristensson, Martin; dePont Christensen, René; Hansen, Torben F; Kjær-Frifeldt, Sanne; Sørensen, Flemming B

    2017-08-29

    Precise prognostic and predictive variables allowing improved post-operative treatment stratification are missing in patients treated for stage II colon cancer (CC). Investigation of tumor infiltrating lymphocytes (TILs) may be rewarding, but the lack of a standardized analytic technique is a major concern. Manual stereological counting is considered the gold standard, but digital pathology with image analysis is preferred due to time efficiency. The purpose of this study was to compare manual stereological estimates of TILs with automatic counts obtained by image analysis, and at the same time investigate the heterogeneity of TILs. From 43 patients treated for stage II CC in 2002 three paraffin embedded, tumor containing tissue blocks were selected one of them representing the deepest invasive tumor front. Serial sections from each of the 129 blocks were immunohistochemically stained for CD3 and CD8, and the slides were scanned. Stereological estimates of the numerical density and area fraction of TILs were obtained using the computer-assisted newCAST stereology system. For the image analysis approach an app-based algorithm was developed using Visiopharm Integrator System software. For both methods the tumor areas of interest (invasive front and central area) were manually delineated by the observer. Based on all sections, the Spearman's correlation coefficients for density estimates varied from 0.9457 to 0.9638 (p < 0.0001), whereas the coefficients for area fraction estimates ranged from 0.9400 to 0.9603 (P < 0.0001). Regarding heterogeneity, intra-class correlation coefficients (ICC) for CD3+ TILs varied from 0.615 to 0.746 in the central area, and from 0.686 to 0.746 in the invasive area. ICC for CD8+ TILs varied from 0.724 to 0.775 in the central area, and from 0.746 to 0.765 in the invasive area. Exact objective and time efficient estimates of numerical densities and area fractions of CD3+ and CD8+ TILs in stage II colon cancer can be obtained by image analysis and are highly correlated to the corresponding estimates obtained by the gold standard based on stereology. Since the intra-tumoral heterogeneity was low, this method may be recommended for quantifying TILs in only one histological section representing the deepest invasive tumor front.

  16. T cell lymphoblastic lymphoma/leukemia within an adrenocorticotropic hormone and thyroid stimulating hormone positive pituitary adenoma: A cytohistological correlation emphasizing importance of intra-operative squash smear.

    PubMed

    Gupta, Rakesh K; Saran, Ravindra K; Srivastava, Arvind K; Jagetia, Anita; Garg, Lalit; Sharma, Mehar C

    2017-08-01

    We present a rare case of primary pituitary T cell lymphoma/leukemia (T-LBL) in association with adrenocorticotropic hormone (ACTH) and thyroid stimulating hormone (TSH) expressing pituitary adenoma in a 55-year-old woman highlighting the importance of intra-operative squash smears examination. The patient presented with complaints of headache, diminution of vision and recent onset altered sensorium. MRI revealed a mass lesion in the sellar-suprasellar region with non-visualization of pituitary gland separately, extending to involve adjacent structures diagnosed as invasive pituitary macroadenoma. Intra-operative tissue was sent for squash smear examination. The cytology showed a tumor comprising of sheets of immature lymphoid cells intermixed with clusters of pituitary acinar cells with many mitoses and tingible body macrophages. A diagnosis of presence of immature lymphoid cells within the pituitary was offered and differentials of infiltration by lymphoma cells from systemic disease versus primary central nervous lymphoma-like lymphoma arising in the pituitary adenoma were considered. Later paraffin section examination and immunohistochemistry corroborated with the squash findings and a final diagnosis of primary pituitary T cell lymphoma/leukemia in association with ACTH and TSH expressing pituitary adenoma was made. To date, only six cases of primary pituitary T cell lymphomas, including three T-LBL cases, have been reported. This is the seventh case and first one additionally describing cytohistological correlation and importance of intra-operative cytology. © 2017 Japanese Society of Neuropathology.

  17. Functional brain connectivity when cooperation fails.

    PubMed

    Balconi, Michela; Vanutelli, Maria Elide; Gatti, Laura

    2018-06-01

    Functional connectivity during cooperative actions is an important topic in social neuroscience that has yet to be answered. Here, we examined the effects of administration of (fictitious) negative social feedback in relation to cooperative capabilities. Cognitive performance and neural activation underlying the execution of joint actions was recorded with functional near-infrared spectroscopy (fNIRS) on prefrontal regions during a task where pairs of participants received negative feedback after their joint action. Performance (error rates (ERs) and response times (RTs)) and intra- and inter-brain connectivity indices were computed, along with the ConIndex (inter-brain/intra-brain connectivity). Finally, correlational measures were considered to assess the relation between these different measures. Results showed that the negative feedback was able to modulate participants' responses for both behavioral and neural components. Cognitive performance was decreased after the feedback. Moreover, decreased inter-brain connectivity and increased intra-brain connectivity was induced by the feedback, whereas the cooperative task pre-feedback condition was able to increase the brain-to-brain coupling, mainly localized within the dorsolateral prefrontal cortex (DLPFC). Finally, the presence of significant correlations between RTs and inter-brain connectivity revealed that ineffective joint action produces the worst cognitive performance and a more 'individual strategy' for brain activity, limiting the inter-brain connectivity. The present study provides a significant contribution to the identification of patterns of intra- and inter-brain functional connectivity when negative social reinforcement is provided in relation to cooperative actions. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Effect of knee angle on neuromuscular assessment of plantar flexor muscles: A reliability study

    PubMed Central

    Cornu, Christophe; Jubeau, Marc

    2018-01-01

    Introduction This study aimed to determine the intra- and inter-session reliability of neuromuscular assessment of plantar flexor (PF) muscles at three knee angles. Methods Twelve young adults were tested for three knee angles (90°, 30° and 0°) and at three time points separated by 1 hour (intra-session) and 7 days (inter-session). Electrical (H reflex, M wave) and mechanical (evoked and maximal voluntary torque, activation level) parameters were measured on the PF muscles. Intraclass correlation coefficients (ICC) and coefficients of variation were calculated to determine intra- and inter-session reliability. Results The mechanical measurements presented excellent (ICC>0.75) intra- and inter-session reliabilities regardless of the knee angle considered. The reliability of electrical measurements was better for the 90° knee angle compared to the 0° and 30° angles. Conclusions Changes in the knee angle may influence the reliability of neuromuscular assessments, which indicates the importance of considering the knee angle to collect consistent outcomes on the PF muscles. PMID:29596480

  19. Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing.

    PubMed

    Sainz, José A; Fernández-Palacín, Ana; Borrero, Carlota; Aquise, Adriana; Ramos, Zenaida; García-Mejido, José A

    2018-04-01

    The aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and pushing. We evaluated 28 nulliparous women at full dilatation under epidural analgesia. We performed a transperineal ultrasound evaluating AoP and PD in the longitudinal plane, and MLA and HPD in the transverse plane. Interclass correlation coefficients (ICC) with 95% CIs and Bland-Altman analysis were used to assess intra- and interobserver measurement's repeatability. The ICC of the ITU for the same observer was adequate for all the parameters (p < .005) AoP 0.98 (95%CI, 0.96-0.99), PD 0.98 (95%CI, 0.97-0.99), MLA 0.99 (95%CI, 0.97-0.99), HPD 0.96 (95%CI, 0.88-0.99). The ICC of the ITU for interobserver was: AoP 0.93 (95%CI, 0.79-0.98), PD 0.92 (95%CI, 0.76-0.97), MLA 0.77 (95%CI, 0.42-0.92), HPD 0.47 (95%CI, -0.12-0.8). The HD had an interobserver correlation of 0.53 (95%CI, 0.1-0.9) (Kappa C). The mean difference of the AoP was 2.42°, of the PD 1 mm and 0.28° MLA (Bland-Altman test). ITU has an adequate intra- and interobserver correlation for its use with contraction and pushing under epidural analgesia. Impact statement What is already known on this subject: The intrapartum transperineal ultrasound parameters can be used with contraction and pushing under epidural analgesia. What the results of this study add to what we know: ITU may be used to evaluate the difficulty of instrumental delivery/to evaluate the difficulty of instrumentation in vaginal operative deliveries and this study concludes that ITU is reproducible during uterine contraction with pushing. What the implications are of these findings for clinical practice and/or further research: Therefore, ITU could be used without difficulty with an adequate intra- and interobserver correlation for the prediction of instrumentation difficulty in operative vaginal deliveries.

  20. Cross-cultural adaptation, reliability, and validity of the Persian version of the Cumberland Ankle Instability Tool.

    PubMed

    Hadadi, Mohammad; Ebrahimi Takamjani, Ismail; Ebrahim Mosavi, Mohammad; Aminian, Gholamreza; Fardipour, Shima; Abbasi, Faeze

    2017-08-01

    The purpose of the present study was to translate and to cross-culturally adapt the Cumberland Ankle Instability Tool (CAIT) into Persian language and to evaluate its psychometric properties. The International Quality of Life Assessment process was pursued to translate CAIT into Persian. Two groups of Persian-speaking individuals, 105 participants with a history of ankle sprain and 30 participants with no history of ankle sprain, were asked to fill out Persian version of CAIT (CAIT-P), Foot and Ankle Ability Measure (FAAM), and Visual Analog Scale (VAS). Data obtained from the first administration of CAIT were used to evaluate floor and ceiling effects, internal consistency, dimensionality, and criterion validity. To determine the test-retest reliability, 45 individuals re-filled CAIT 5-7 days after the first session. Cronbach's alpha was over the cutoff point of 0.70 for both ankles and in both groups. The intra-class correlation coefficient was high for right (0.95) and left (0.91) ankles. There was a strong correlation between each item and the total score of the CAIT-P. Although the CAIT-P had strong correlation with VAS, its correlation with both subscales of FAAM was moderate. The CAIT-P has good validity and reliability and it can be used by clinicians and researchers for identification and investigation of functional ankle instability. Implications for Rehabilitation Chronic ankle instability is one of the most common consequences of acute ankle sprain. Cumberland Ankle Instability Tool is an acceptable measure to determine functional ankle instability and its severity. The Persian version of Cumberland Ankle Instability Tool is a valid and reliable tool for clinical and research purpose in Persian-speaking individuals.

Top