Inappropriate ICD discharges due to "triple counting" during normal sinus rhythm.
Khan, Ejaz; Voudouris, Apostolos; Shorofsky, Stephen R; Peters, Robert W
2006-11-01
To describe the clinical course of a patient with multiple ICD shocks in the setting of advanced renal failure and hyperkalemia. The patient was brought to the Electrophysiology Laboratory where the ICD was interrogated. The patient was found to be hyperkalemic (serum potassium 7.6 mg/dl). Analysis of stored intracardiac electrograms from the ICD revealed "triple counting" (twice during his QRS complex and once during the T wave) and multiple inappropriate shocks. Correction of his electrolyte abnormality normalized his electrogram and no further ICD activations were observed. Electrolyte abnormalities can distort the intracardiac electrogram in patients with ICD's and these changes can lead to multiple inappropriate shocks.
Shariat, M H; Gazor, S; Redfearn, D
2015-08-01
Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, is an extremely costly public health problem. Catheter-based ablation is a common minimally invasive procedure to treat AF. Contemporary mapping methods are highly dependent on the accuracy of anatomic localization of rotor sources within the atria. In this paper, using simulated atrial intracardiac electrograms (IEGMs) during AF, we propose a computationally efficient method for localizing the tip of the electrical rotor with an Archimedean/arithmetic spiral wavefront. The proposed method deploys the locations of electrodes of a catheter and their IEGMs activation times to estimate the unknown parameters of the spiral wavefront including its tip location. The proposed method is able to localize the spiral as soon as the wave hits three electrodes of the catheter. Our simulation results show that the method can efficiently localize the spiral wavefront that rotates either clockwise or counterclockwise.
Seitz, Julien; Bars, Clément; Théodore, Guillaume; Beurtheret, Sylvain; Lellouche, Nicolas; Bremondy, Michel; Ferracci, Ange; Faure, Jacques; Penaranda, Guillaume; Yamazaki, Masatoshi; Avula, Uma Mahesh R.; Curel, Laurence; Siame, Sabrina; Berenfeld, Omer; Pisapia, André; Kalifa, Jérôme
2017-01-01
Background The use of intra-cardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. We evaluated an electrogram marker of AF drivers: the clustering of electrograms exhibiting spatio-temporal dispersion — regardless of whether such electrograms were fractionated or not. Objective To evaluate the usefulness of spatio-temporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. Methods We prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. We tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatio-temporal dispersion of AF electrograms, we conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. Results Ablation at dispersion areas terminated AF in 95%. After ablation of 17±10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4±0.5 procedure/patient vs 41% in the validation set after 1.5±0.5 procedure/patient (arrhythmia free-survival rates: 85% vs 59%, log rank P<0.001). In comparison with the validation set, radiofrequency times (49 ± 21 minutes vs 85 ± 34.5 minutes, p=0.001) and procedure times (168 ± 42 minutes vs. 230 ± 67 minutes, p<.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. Conclusions The clustering of intra-cardiac electrograms exhibiting spatio-temporal dispersion is indicative of AF drivers. Their ablation allows for a non-extensive and patient-tailored approach to AF ablation. Clinical trial.gov number: NCT02093949 PMID:28104073
Pezo Nikolić, Borka; Lovrić, Daniel; Ljubas Maček, Jana; Rešković Lukšić, Vlatka; Matasić, Richard; Šeparović Hanževački, Jadranka
2017-12-01
Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.
Oesterlein, Tobias Georg; Schmid, Jochen; Bauer, Silvio; Jadidi, Amir; Schmitt, Claus; Dössel, Olaf; Luik, Armin
2016-04-01
Progress in biomedical engineering has improved the hardware available for diagnosis and treatment of cardiac arrhythmias. But although huge amounts of intracardiac electrograms (EGMs) can be acquired during electrophysiological examinations, there is still a lack of software aiding diagnosis. The development of novel algorithms for the automated analysis of EGMs has proven difficult, due to the highly interdisciplinary nature of this task and hampered data access in clinical systems. Thus we developed a software platform, which allows rapid implementation of new algorithms, verification of their functionality and suitable visualization for discussion in the clinical environment. A software for visualization was developed in Qt5 and C++ utilizing the class library of VTK. The algorithms for signal analysis were implemented in MATLAB. Clinical data for analysis was exported from electroanatomical mapping systems. The visualization software KaPAVIE (Karlsruhe Platform for Analysis and Visualization of Intracardiac Electrograms) was implemented and tested on several clinical datasets. Both common and novel algorithms were implemented which address important clinical questions in diagnosis of different arrhythmias. It proved useful in discussions with clinicians due to its interactive and user-friendly design. Time after export from the clinical mapping system to visualization is below 5min. KaPAVIE(2) is a powerful platform for the development of novel algorithms in the clinical environment. Simultaneous and interactive visualization of measured EGM data and the results of analysis will aid diagnosis and help understanding the underlying mechanisms of complex arrhythmias like atrial fibrillation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Shariat, Mohammad Hassan; Gazor, Saeed; Redfearn, Damian
2016-08-01
In this paper, we study the problem of the cardiac conduction velocity (CCV) estimation for the sequential intracardiac mapping. We assume that the intracardiac electrograms of several cardiac sites are sequentially recorded, their activation times (ATs) are extracted, and the corresponding wavefronts are specified. The locations of the mapping catheter's electrodes and the ATs of the wavefronts are used here for the CCV estimation. We assume that the extracted ATs include some estimation errors, which we model with zero-mean white Gaussian noise values with known variances. Assuming stable planar wavefront propagation, we derive the maximum likelihood CCV estimator, when the synchronization times between various recording sites are unknown. We analytically evaluate the performance of the CCV estimator and provide its mean square estimation error. Our simulation results confirm the accuracy of the proposed method and the error analysis of the proposed CCV estimator.
Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis
NASA Astrophysics Data System (ADS)
Kachenoura, A.; Porée, F.; Hernández, A. I.; Carrault, G.
2008-12-01
Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs) are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG) from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA). The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.
Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias
2013-01-01
An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. PMID:21337409
Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias
2011-03-01
An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. Copyright © 2010 Wiley-Liss, Inc.
Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi
2018-05-02
The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These findings pave the way towards a subsystem which can be included in current intracardiac navigation systems assisted by force contact sensors, and it can provide the clinician with an estimate of the reliability on the tissue-catheter contact in the point-by-point EGM acquisition procedure.
Muñoz-Romero, Sergio; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; García-Alberola, Arcadi
2018-01-01
The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These findings pave the way towards a subsystem which can be included in current intracardiac navigation systems assisted by force contact sensors, and it can provide the clinician with an estimate of the reliability on the tissue-catheter contact in the point-by-point EGM acquisition procedure. PMID:29724033
Liu, Enzhao; Xu, Gang; Liu, Tong; Ye, Lan; Zhang, Qitong; Zhao, Yanshu; Li, Guangping
2015-03-01
Discrete potentials (DPs) have been recorded and targeted as the site of ablation of the outflow tract arrhythmias. The aim of the present study was to investigate the significance of DPs with respect to mapping and ablation for idiopathic outflow tract premature ventricular contractions (PVCs) or ventricular tachycardias (VTs). Seventeen consecutive patients with idiopathic right or left ventricular outflow tract PVCs/VTs who underwent radiofrequency catheter ablation were included. Intracardiac electrograms during the mapping and ablation were analysed. During sinus rhythm, sharp high-frequency DPs that displayed double or multiple components were recorded following or buried in the local ventricular electrograms in all of the 17 patients, peak amplitude 0.51 ± 0.21 mV. The same potential was recorded prior to the local ventricular potential of the PVCs/VTs. Spontaneous reversal of the relationship of the DPs to the local ventricular electrogram during the arrhythmias was noted. The DPs were related to a region of low voltage showed by intracardiac high-density contact mapping. At the sites with DPs, lower unipolar and bipolar ventricular voltage of sinus beats were noted compared with the adjacent regions without DPs (unipolar: 6.1 ± 1.8 vs. 8.3 ± 2.3 mV, P < 0.05; bipolar: 0.62 ± 0.45 vs. 1.03 ± 0.60 mV, P < 0.05). The targeted DPs were still present in 12 patients after successful elimination of the ectopies. Discrete potentials were not present in seven controls. Discrete potentials and related low-voltage regions were common in idiopathic outflow tract ventricular arrhythmias. Discrete potential- and substrate-guided ablation strategy will help to reduce the recurrence of idiopathic outflow tract arrhythmias. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G
2016-01-01
Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF pathophysiology and to investigate the effect of anti-arrhythmic drugs. © 2014 EVJ Ltd.
Alagoz, Celal; Guez, Allon; Cohen, Andrew; Bullinga, John R
2015-08-01
Analysis of electrical activation patterns such as re-entries during atrial fibrillation (Afib) is crucial in understanding arrhythmic mechanisms and assessment of diagnostic measures. Spiral waves are a phenomena that provide intuitive basis for re-entries occurring in cardiac tissue. Distinct spiral wave behaviors such as stable spiral waves, meandering spiral waves, and spiral wave break-up may have distinct electrogram manifestations on a mapping catheter. Hence, it is desirable to have an automated classification of spiral wave behavior based on catheter recordings for a qualitative characterization of spatiotemporal electrophysiological activity on atrial tissue. In this study, we propose a method for classification of spatiotemporal characteristics of simulated atrial activation patterns in terms of distinct spiral wave behaviors during Afib using two different techniques: normalized compressed distance (NCD) and normalized FFT (NFFTD). We use a phenomenological model for cardiac electrical propagation to produce various simulated spiral wave behaviors on a 2D grid and labeled them as stable, meandering, or breakup. By mimicking commonly used catheter types, a star shaped and a circular shaped both of which do the local readings from atrial wall, monopolar and bipolar intracardiac electrograms are simulated. Virtual catheters are positioned at different locations on the grid. The classification performance for different catheter locations, types and for monopolar or bipolar readings were also compared. We observed that the performance for each case differed slightly. However, we found that NCD performance is superior to NFFTD. Through the simulation study, we showed the theoretical validation of the proposed method. Our findings suggest that a qualitative wavefront activation pattern can be assessed during Afib without the need for highly invasive mapping techniques such as multisite simultaneous electrogram recordings.
Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.
Knight, Bradley; Ayers, Gregory M; Cohen, Todd J
2008-05-01
Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.
Real-Time Rotational Activity Detection in Atrial Fibrillation
Ríos-Muñoz, Gonzalo R.; Arenal, Ángel; Artés-Rodríguez, Antonio
2018-01-01
Rotational activations, or spiral waves, are one of the proposed mechanisms for atrial fibrillation (AF) maintenance. We present a system for assessing the presence of rotational activity from intracardiac electrograms (EGMs). Our system is able to operate in real-time with multi-electrode catheters of different topologies in contact with the atrial wall, and it is based on new local activation time (LAT) estimation and rotational activity detection methods. The EGM LAT estimation method is based on the identification of the highest sustained negative slope of unipolar signals. The method is implemented as a linear filter whose output is interpolated on a regular grid to match any catheter topology. Its operation is illustrated on selected signals and compared to the classical Hilbert-Transform-based phase analysis. After the estimation of the LAT on the regular grid, the detection of rotational activity in the atrium is done by a novel method based on the optical flow of the wavefront dynamics, and a rotation pattern match. The methods have been validated using in silico and real AF signals. PMID:29593566
Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A
2006-02-01
Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was <0.35 mV-mV, then the detected rhythm was considered noise due to a lead failure. The first ICD-detected episode of lead failure and inappropriate detection from 24 ICD patients with a pace/sense lead failure and all ventricular arrhythmias from 56 ICD patients without a lead failure were selected. The stored data were analyzed to determine the sensitivity and specificity of the algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.
Zong, W; Wang, P; Leung, B; Moody, G B; Mark, R G
2002-01-01
The advent of implantable cardioverter defibrillators (ICDs) has resulted in significant reductions in mortality in patients at high risk for sudden cardiac death. Extensive related basic research and clinical investigation continue. ICDs typically record intracardiac electrograms and inter-beat intervals along with device settings during episodes of device delivery of therapy. Researchers wishing to study these data further have until now been limited to viewing paper plots. In support of multi-center clinical studies of patients with ICDs, we have developed a web based searchable ICD data archiving system, which allows users to use a web browser to upload ICD data from diskettes to a server where the data are automatically processed and archived. Users can view and download the archived ICD data directly via the web. The entire system is built from open source software. At present more than 500 patient ICD data sets have been uploaded to and archived in the system. This project will be of value not only to those who wish to conduct research using ICD data, but also to clinicians who need to archive and review ICD data collected from their patients.
Zeemering, Stef; Bonizzi, Pietro; Maesen, Bart; Peeters, Ralf; Schotten, Ulrich
2015-01-01
Spatiotemporal complexity of atrial fibrillation (AF) patterns is often quantified by annotated intracardiac contact mapping. We introduce a new approach that applies recurrence plot (RP) construction followed by recurrence quantification analysis (RQA) to epicardial atrial electrograms, recorded with a high-density grid of electrodes. In 32 patients with no history of AF (aAF, n=11), paroxysmal AF (PAF, n=12) and persistent AF (persAF, n=9), RPs were constructed using a phase space electrogram embedding dimension equal to the estimated AF cycle length. Spatial information was incorporated by 1) averaging the recurrence over all electrodes, and 2) by applying principal component analysis (PCA) to the matrix of embedded electrograms and selecting the first principal component as a representation of spatial diversity. Standard RQA parameters were computed on the constructed RPs and correlated to the number of fibrillation waves per AF cycle (NW). Averaged RP RQA parameters showed no correlation with NW. Correlations improved when applying PCA, with maximum correlation achieved between RP threshold and NW (RR1%, r=0.68, p <; 0.001) and RP determinism (DET, r=-0.64, p <; 0.001). All studied RQA parameters based on the PCA RP were able to discriminate between persAF and aAF/PAF (DET persAF 0.40 ± 0.11 vs. 0.59 ± 0.14/0.62 ± 0.16, p <; 0.01). RP construction and RQA combined with PCA provide a quick and reliable tool to visualize dynamical behaviour and to assess the complexity of contact mapping patterns in AF.
Madeira, João; Parreira, Leonor; Amador, Pedro; Soares, Luís
2013-10-14
Riata and Riata ST silicone defibrillation leads are prone to externalization of conductors due to inside-out abrasion in the high-voltage system, causing structural damage which may be accompanied by electrical failure. These situations are easily detected by fluoroscopy or radiology and by inspection of intracardiac electrograms and/or measurement of impedance. However, older pulse generators do not automatically perform all the measurements needed to assess the integrity of the high-voltage electrical system, nor do they have patient notifier alerts in case of dysfunction. The authors describe the case of a patient in whom structural damage was detected on fluoroscopy during pulse generator replacement. They discuss the best strategy in these patients, considering current knowledge of this dysfunction. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Koa-Wing, Michael; Nakagawa, Hiroshi; Luther, Vishal; Jamil-Copley, Shahnaz; Linton, Nick; Sandler, Belinda; Qureshi, Norman; Peters, Nicholas S; Davies, D Wyn; Francis, Darrel P; Jackman, Warren; Kanagaratnam, Prapa
2015-11-15
Ripple Mapping (RM) is designed to overcome the limitations of existing isochronal 3D mapping systems by representing the intracardiac electrogram as a dynamic bar on a surface bipolar voltage map that changes in height according to the electrogram voltage-time relationship, relative to a fiduciary point. We tested the hypothesis that standard approaches to atrial tachycardia CARTO™ activation maps were inadequate for RM creation and interpretation. From the results, we aimed to develop an algorithm to optimize RMs for future prospective testing on a clinical RM platform. CARTO-XP™ activation maps from atrial tachycardia ablations were reviewed by two blinded assessors on an off-line RM workstation. Ripple Maps were graded according to a diagnostic confidence scale (Grade I - high confidence with clear pattern of activation through to Grade IV - non-diagnostic). The RM-based diagnoses were corroborated against the clinical diagnoses. 43 RMs from 14 patients were classified as Grade I (5 [11.5%]); Grade II (17 [39.5%]); Grade III (9 [21%]) and Grade IV (12 [28%]). Causes of low gradings/errors included the following: insufficient chamber point density; window-of-interest<100% of cycle length (CL); <95% tachycardia CL mapped; variability of CL and/or unstable fiducial reference marker; and suboptimal bar height and scar settings. A data collection and map interpretation algorithm has been developed to optimize Ripple Maps in atrial tachycardias. This algorithm requires prospective testing on a real-time clinical platform. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
McGillivray, Max Falkenberg; Cheng, William; Peters, Nicholas S.; Christensen, Kim
2018-04-01
Mapping resolution has recently been identified as a key limitation in successfully locating the drivers of atrial fibrillation (AF). Using a simple cellular automata model of AF, we demonstrate a method by which re-entrant drivers can be located quickly and accurately using a collection of indirect electrogram measurements. The method proposed employs simple, out-of-the-box machine learning algorithms to correlate characteristic electrogram gradients with the displacement of an electrogram recording from a re-entrant driver. Such a method is less sensitive to local fluctuations in electrical activity. As a result, the method successfully locates 95.4% of drivers in tissues containing a single driver, and 95.1% (92.6%) for the first (second) driver in tissues containing two drivers of AF. Additionally, we demonstrate how the technique can be applied to tissues with an arbitrary number of drivers. In its current form, the techniques presented are not refined enough for a clinical setting. However, the methods proposed offer a promising path for future investigations aimed at improving targeted ablation for AF.
Electrograms (ECG, EEG, EMG, EOG).
Reilly, Richard B; Lee, T Clive
2010-01-01
There is a constant need in medicine to obtain objective measurements of physical and cognitive function as the basis for diagnosis and monitoring of health. The body can be considered as a chemical and electrical system supported by a mechanical structure. Measuring and quantifying such electrical activity provides a means for objective examination of heath status. The term electrogram, from the Greek electro meaning electricity and gram meaning write or record, is the broad definition given to the recording of electrical signal from the body. In order that comparisons of electrical activity can be made against normative data, certain methods and procedures have been defined for different electrograms. This paper reviews these methods and procedures for the more typical electrograms associated with some of the major organs in the body, providing a first point of reference for the reader.
II.3. Electrograms (ECG, EEG, EMG, EOG).
Reilly, Richard B; Lee, T Clive
2010-01-01
There is a constant need in medicine to obtain objective measurements of physical and cognitive function as the basis for diagnosis and monitoring of health. The body can be considered as a chemical and electrical system supported by a mechanical structure. Measuring and quantifying such electrical activity provides a means for objective examination of heath status. The term electrogram, from the Greek electro meaning electricity and gram meaning write or record, is the broad definition given to the recording of electrical signal from the body. In order that comparisons of electrical activity can be made against normative data, certain methods and procedures have been defined for different electrograms. This paper reviews these methods and procedures for the more typical electrograms associated with some of the major organs in the body, providing a first point of reference for the reader.
Intracardiac Shunting and Stroke in Children: A Systematic Review
Dowling, Michael M.; Ikemba, Catherine M.
2017-01-01
In adults, patent foramen ovale or other potential intracardiac shunts are established risk factors for stroke via paradoxical embolization. Stroke is less common in children and risk factors differ. The authors examined the literature on intracardiac shunting and stroke in children, identifying the methods employed, the prevalence of detectible intracardiac shunts, associated conditions, and treatments. PubMed searches with keywords related to intracardiac shunting and stroke in children identified articles of interest. Additional articles were identified via citations in these articles or in reviews. The authors found that studies of intracardiac shunting in children with stroke are limited. No controlled studies were identified. Detection methods vary and the prevalence of echocardiographically detectible intracardiac shunting appears lower than reported in adults and autopsy studies. Defining the role of intracardiac shunting in pediatric stroke will require controlled studies with unified detection methods in populations stratified by additional risk factors for paradoxical embolization. Optimal treatment is unclear. PMID:21212453
Third-generation mobile phones (UMTS) do not interfere with permanent implanted pacemakers.
Ismail, Mohamed M; Badreldin, Akmal M A; Heldwein, Matthias; Hekmat, Khosro
2010-07-01
Third-generation mobile phones, UMTS (Universal Mobile Telecommunication System), were recently introduced in Europe. The safety of these devices with regard to their interference with implanted pacemakers is as yet unknown and is the point of interest in this study. The study comprised 100 patients with permanent pacemaker implantation between November 2004 and June 2005. Two UMTS cellular phones (T-Mobile, Vodafone) were tested in the standby, dialing, and operating mode with 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms (ECGs), intracardiac electrograms, and marker channels were recorded when calls were made by a stationary phone to cellular phone. All pacemakers were tested under a "worst-case scenario," which includes a programming of the pacemaker to unipolar sensing and pacing modes and inducing of a maximum sensitivity setting during continuous pacing of the patient. Patients had pacemaker implantation between June 1990 and April 2005. The mean age was 68.4 +/- 15.1 years. Regardless of atrial and ventricular sensitivity settings, both UMTS mobile phones (Nokia 6650 and Motorola A835) did not show any interference with all tested pacemakers. In addition, both cellular phones did not interfere with the marker channels and the intracardiac ECGs of the pacemakers. Third-generation mobile phones are safe for patients with permanent pacemakers. This is due to the high-frequency band for this system (1,800-2,200 MHz) and the low power output between 0.01 W and 0.25 W.
Gharaviri, Ali; Brooks, Anthony; Chapman, Darius; Lau, Dennis H.; Roberts-Thomson, Kurt C.; Sanders, Prashanthan
2014-01-01
Background Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. Objective To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. Methods and Results We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. Conclusions The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour. PMID:25401331
Multifractal analysis for grading complex fractionated electrograms in atrial fibrillation.
Orozco-Duque, A; Novak, D; Kremen, V; Bustamante, J
2015-11-01
Complex fractionated atrial electrograms provide an important tool for identifying arrhythmogenic substrates that can be used to guide catheter ablation for atrial fibrillation (AF). However, fractionation is a phenomenon that remains unclear. This paper aims to evaluate the multifractal properties of electrograms in AF in order to propose a method based on multifractal analysis able to discriminate between different levels of fractionation. We introduce a new method, the h-fluctuation index (hFI), where h is the generalised Hurst exponent, to extract information from the shape of the multifractal spectrum. Two multifractal frameworks are evaluated: multifractal detrended fluctuation analysis and wavelet transform modulus maxima. hFI is exemplified through its application in synthetic signals, and it is evaluated in a database of electrograms labeled on the basis of four degrees of fractionation. We compare the performance of hFI with other indexes, and find that hFI outperforms them. The results of the study provide evidence that multifractal analysis is useful for studying fractionation phenomena in AF electrograms, and indicate that hFI can be proposed as a tool for grade fractionation associated with the detection of target sites for ablation in AF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohen, S.I.; Bharati, S.; Glass, J.
1981-04-01
A 20-year-old man contracted Hodgkin's disease and was treated with mantle radiotherapy. Heart block developed 11 years later. Electrocardiograms revealed predominant atrioventricular (AV) block and occasional AV conduction. Intracardiac electrograms demonstrated that the site of AV block was above the level of the His bundle. A permanent transvenous pacemaker was implanted. Seven months later the patient died of complications from cryptococcal meningitis. Pathological study of the heart revealed marked arteriosclerosis with fibrosis of the epicardium, myocardium, and endocardium. Examination of the conduction system revealed extensive arteriolosclerosis of the sinoatrial node and its approaches. In addition, there was marked fibrosis ofmore » the approaches to the AV node, the AV bundle, and both bundle branches. There was no evidence of Hodgkin's disease. This case documents the rare occurrence of AV block due to tissue destruction by radiotherapy. There was a good correlation between block proximal to the His bundle recording site and fibrosis of the approaches to the AV node.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohen, S.I.; Bharati, S.; Glass, J.
1981-04-01
A 20-year-old man contracted Hodgkin's disease and was treated with mantle radiotherapy. Heart block developed 11 years later. Electrocardiograms revealed predominant atrioventricular (AV) block and occasional AV conduction. Intracardiac electrograms demonstrated that the site of AV block was above the level of the His bundle. A permanent transvenous pacemaker was implanted. Seven months later the patient died of complications from cryptococcal meningitis. Pathological study of the heart revealed marked arteriosclerosis with fibrosis of the epicardium, myocardium, and endocardium. Examination of the conduction system revealed extensive arteriolosclerosis of the sinoatrial node and its approaches. In addition, there was marked fibrosis ofmore » the approaches to the AV node, the AV bundle, and both bundle branches. There was no evidence of Hodgkin's disease. This case documents the rare occurrence of AV block due to tissue destruction by radiotherapy. There was a good correlation between block proximal to the His bundle recording site and fibrosis of the approaches to the AV node.« less
Electrogram Morphology Recurrence Patterns during Atrial Fibrillation
Ng, Jason; Gordon, David; Passman, Rod S.; Knight, Bradley P.; Arora, Rishi; Goldberger, Jeffrey J.
2014-01-01
Background Traditional mapping of atrial fibrillation (AF) is limited by changing electrogram morphologies and variable cycle lengths. Objective We tested the hypothesis that morphology recurrence plot analysis would identify sites of stable and repeatable electrogram morphology patterns. Methods AF electrograms recorded from left atrial (LA) and right atrial (RA) sites in 19 patients (10 male, 59±10 years old) prior to AF ablation were analyzed. Morphology recurrence plots for each electrogram recording were created by cross-correlation of each automatically detected activation with every other activation in the recording. A recurrence percentage, the percentage of the most common morphology, and the mean cycle length of activations with the most common morphology (CLR) were computed. Results The morphology recurrence plots commonly showed checkerboard patterns of alternating high and low cross correlation values indicating periodic recurrences in morphologies. The mean recurrence percentage for all sites and all patients was 38±25%. The highest recurrence percentage per patient averaged 83±17%. The highest recurrence percentage was located in the RA in 5 patients and in the LA in 14 patients. Patients with sites of shortest CLR in the LA and RA had ablation failure rates of 25% and 100%, respectively (HR=4.95; p=0.05). Conclusions A new technique to characterize electrogram morphology recurrence demonstrated that there is a distribution of sites with high and low repeatability of electrogram morphologies. Sites with rapid activation of highly repetitive morphology patterns may be critical to sustaining AF. Further testing of this approach to map and ablate AF sources is warranted. PMID:25101485
New method: calculation of magnification factor from an intracardiac marker.
Cha, S D; Incarvito, J; Maranhao, V
1983-01-01
In order to calculate a magnification factor (MF), an intracardiac marker (pigtail catheter with markers) was evaluated using a new formula and correlated with the conventional grid method. By applying the Pythagorean theorem and trigonometry, a new formula was developed, which is (formula; see text) In an experimental study, MF by the intracardiac markers was 0.71 +/- 0.15 (M +/- SD) and one by the grid method was 0.72 +/- 0.15, with a correlation coefficient of 0.96. In patients study, MF by the intracardiac markers was 0.77 +/- 0.06 and one by the grid method was 0.77 +/- 0.05. We conclude that this new method is simple and the results were comparable to the conventional grid method at mid-chest level.
Unipolar atrial electrogram morphology from an epicardial and endocardial perspective.
van der Does, Lisette J M E; Knops, Paul; Teuwen, Christophe P; Serban, Corina; Starreveld, Roeliene; Lanters, Eva A H; Mouws, Elisabeth M J P; Kik, Charles; Bogers, Ad J J C; de Groot, Natasja M S
2018-02-22
Endo-epicardial asynchrony (EEA) and the interplay between the endocardial and epicardial layers could be important in the pathophysiology of atrial arrhythmias. The morphologic differences between epicardial and endocardial atrial electrograms have not yet been described, and electrogram morphology may hold information about the presence of EEA. The purpose of this study was to directly compare epicardial to endocardial unipolar electrogram morphology during sinus rhythm (SR) and to evaluate whether EEA contributes to electrogram fractionation by correlating fractionation to spatial activation patterns. In 26 patients undergoing cardiac surgery, unipolar electrograms were simultaneously recorded from the epicardium and endocardium at the inferior, middle, and superior right atrial (RA) free wall during SR. Potentials were analyzed for epi-endocardial differences in local activation time, voltage, RS ratio, and fractionation. The surrounding and opposite electrograms of fractionated deflections were evaluated for corresponding local activation times in order to determine whether fractionation originated from EEA. The superior RA was predisposed to delayed activation, EEA, and fractionation. Both epicardial and endocardial electrograms demonstrated an S-predominance. Fractionation was mostly similar between the 2 sides; however, incidentally deflections up to 4 mV on 1 side could be absent on the other side. Remote activation was responsible for most fractionated deflections (95%) in SR, of which 4% could be attributed to EEA. Local epi-endocardial differences in electrogram fractionation occur occasionally during SR but will likely increase during arrhythmias due to increasing EEA and (functional) conduction disorders. Electrogram fractionation can originate from EEA, and this study demonstrated that unipolar electrogram fractionation can potentially identify EEA. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Symmetrical compression distance for arrhythmia discrimination in cloud-based big-data services.
Lillo-Castellano, J M; Mora-Jiménez, I; Santiago-Mozos, R; Chavarría-Asso, F; Cano-González, A; García-Alberola, A; Rojo-Álvarez, J L
2015-07-01
The current development of cloud computing is completely changing the paradigm of data knowledge extraction in huge databases. An example of this technology in the cardiac arrhythmia field is the SCOOP platform, a national-level scientific cloud-based big data service for implantable cardioverter defibrillators. In this scenario, we here propose a new methodology for automatic classification of intracardiac electrograms (EGMs) in a cloud computing system, designed for minimal signal preprocessing. A new compression-based similarity measure (CSM) is created for low computational burden, so-called weighted fast compression distance, which provides better performance when compared with other CSMs in the literature. Using simple machine learning techniques, a set of 6848 EGMs extracted from SCOOP platform were classified into seven cardiac arrhythmia classes and one noise class, reaching near to 90% accuracy when previous patient arrhythmia information was available and 63% otherwise, hence overcoming in all cases the classification provided by the majority class. Results show that this methodology can be used as a high-quality service of cloud computing, providing support to physicians for improving the knowledge on patient diagnosis.
Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Ohashi, Takuya; Uematsu, Masaaki
2017-05-01
The efficacy of low-voltage-guided ablation in addition to pulmonary vein (PV) isolation for atrial fibrillation (AF) has been reported with voltage mapping being performed during sinus rhythm (SR) or AF. The study aimed to compare the left atrial voltage between SR and AF in association with the electrogram waveform. This prospective observational study included 30 consecutive patients with persistent AF. After completion of PV isolation, electrogram points were taken during both SR and AF at the identical locations evenly throughout the left atrium. Electrograms were divided into two types: normal (sharp electrogram with ≤3 peaks or duration <50 ms) and fractionated (>3 peaks and duration ≥50 ms). During SR, 14 (47%) patients had low-voltage (0.5 mV) substrate with an area of 6.8 ± 4.5 cm 2 . In a total of 1,063 point pairs, 135 (13%) demonstrated a fractionated electrogram during SR and 483 (45%) during AF. The locations with fractionated electrograms during AF more frequently showed fractionation during SR compared to those with normal electrograms during AF (23% vs 5%, P < 0.0001), and had lower amplitude during SR (1.47 ± 1.29 mV vs 2.03 ± 1.19 mV, P < 0.0001). Electrogram amplitude was higher during SR than that during AF (1.77 ± 1.27 mV vs 0.96 ± 0.77 mV, P < 0.0001) with a weak correlation (r = 0.56, P < 0.0001). Subgroup analyses revealed that the correlation was relatively strong (r = 0.73, P < 0.0001) among the electrogram amplitudes with normal waveform during SR and AF. Significant differences in electrogram voltage and fractionation degree may exist between SR and AF at the same locations in patients with persistent AF. © 2017 Wiley Periodicals, Inc.
Ganesan, Anand N; Kuklik, Pawel; Gharaviri, Ali; Brooks, Anthony; Chapman, Darius; Lau, Dennis H; Roberts-Thomson, Kurt C; Sanders, Prashanthan
2014-01-01
Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour.
Rotor Meandering Contributes to Irregularity in Electrograms during Atrial Fibrillation
Zlochiver, Sharon; Yamazaki, Masatoshi; Kalifa, Jerome; Berenfeld, Omer
2010-01-01
Radiofrequency ablation therapy of atrial fibrillation (AF) recently incorporated the analysis of dominant frequency (DF) and/or electrogram fractionation for guidance. However, the relationships between DF, fractionation and spatio-temporal characteristics of the AF source remain unclear. We hypothesize that meandering reentrant AF source contributes to the wave fractionation and is reflected in the power spectrum of local electrograms elsewhere in the rotor’s surroundings. Methods Meandering rotors as AF sources were simulated in 2D models of human atrial tissue and recorded in isolated sheep hearts. Non-dominant elements of the signals were differentiated from the dominant elements using singular value decomposition, whereby the purely periodic constituent (PC) relating to the rotor’s DF was eliminated rendering a residual constituent (RC) that consisted of all other activity. Results Spectral analysis of the decomposed constituents revealed peaks corresponding to the meandering frequency of the rotor tip, the magnitudes of which were proportional to the size of, and the distance to the rotor core. Similar analyses on epicardial optical signals and electrograms from isolated sheep hearts, as well as human complex fractionated atrial electrograms demonstrated applicability of the approach. Conclusion Increased meandering of the rotor driving AF reduces activation periodicity and increases fractionation. The spectral manifestation of the rotor activity beyond the meandering region makes it possible to characterize AF source stability, as well as DF in humans using electrode mapping. PMID:18534369
Narayan, Sanjiv M.; Shivkumar, Kalyanam; Krummen, David E.; Miller, John M.; Rappel, Wouter-Jan
2013-01-01
Background The foundation for successful arrhythmia ablation is the mapping of electric propagation to identify underlying mechanisms. In atrial fibrillation (AF), however, mapping is difficult so that ablation has often targeted electrogram features, with mixed results. We hypothesized that wide field-of-view (panoramic) mapping of both atria would identify causal mechanisms for AF and allow interpretation of local electrogram features, including complex fractionated atrial electrograms (CFAE). Methods and Results Contact mapping was performed using biatrial multipolar catheters in 36 AF subjects (29 persistent). Stable AF rotors (spiral waves) or focal sources were seen in 35 of 36 cases and targeted for ablation (focal impulse and rotor modulation) before pulmonary vein isolation. In 31 of 36 subjects (86.1%), AF acutely terminated (n=20; 16 to sinus rhythm) or organized (n=11; 19±8% slowing) with 2.5 minutes focal impulse and rotor modulation (interquartile range, 1.0–3.1) at one source, defined as the primary source. Subjects exhibited 2.1±1.0 concurrent AF sources of which the primary, by phase mapping, precessed in limited areas (persistent 2.5±1.7 versus paroxysmal 1.7±0.5 cm2; P=0.30). Notably, source regions showed mixed electrogram amplitudes and CFAE grades that did not differ from surrounding atrium (P=NS). AF sources were not consistently surrounded by CFAE (P=0.67). Conclusions Stable rotors and focal sources for human AF were revealed by contact panoramic mapping (focal impulse and rotor modulation mapping), but not by electrogram footprints. AF sources precessed within areas of ≈2 cm2, with diverse voltage characteristics poorly correlated with CFAE. Most CFAE sites lie remote from AF sources and are not suitable targets for catheter ablation of AF. PMID:23392583
Left ventricular approach for recording His bundle potential in man.
Lee, Y S; Lien, W P
1975-06-01
The electrical potentials of the His bundle (HB) were recorded from the left ventricular endocardial surface in 28 patients ranging from 16 to 63 years of age. In 14 of the patients the left bundle branch (LB) potentials were also obtained. Placement of a bipolar electrode catheter tip toward the interventricular septum, right at and also 1 to 2 cm below the aortic valve, resulted in stable recordings of both potentials in successive cardiac cycles even at performing atrial or HB pacing from the right heart. The following intervals were measured in milliseconds (msec): P-A, A-H, H, H-V, LB, and LB-V. The average values in 12 patients (average age 26 plus or minus 7 years and average heart rate 90 plus or minus 16 beats per minute) with normal A-V conduction were as follows: P-A 28 plus or minus 7, A-H 76 plus or minus 16, H 19 plus or minus 3 and H-V 45 plus or minus 6 msec. The average values for LB and LB-V in 10 of these 12 patients were 15 plus or minus 3 and 25 plus or minus 3 msec respectively. Validation of the His bundle electrogram (HBE) from the left ventricular endocardial surface was based on simultaneous recordings of the intracardiac electrograms from both left and right sides of the heart in 18 patients. The individual average values for the intervals obtained from both sides of the heart in these patients were statistically not different, except that the H potential was slightly longer in duration fr m the left heart (P equals 0.05). Among these, 16 showed simultaneous onset of the H potentials, and the LB-V and RB-V conduction times from comparable points were almost the same. Indications for the left sided electro-physiologic studies include the following situations: (a) inability to record H from the right of the heart; (b) giant right atrium; and (c) possibly during atrial fibrillation.
Grimm, W; Menz, V; Hoffmann, J; Maisch, B
1998-04-01
Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 +/- 21 beats/min) during 18 +/- 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for sustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.
Tobón, Catalina; Ruiz-Villa, Carlos A.; Heidenreich, Elvio; Romero, Lucia; Hornero, Fernando; Saiz, Javier
2013-01-01
The most common sustained cardiac arrhythmias in humans are atrial tachyarrhythmias, mainly atrial fibrillation. Areas of complex fractionated atrial electrograms and high dominant frequency have been proposed as critical regions for maintaining atrial fibrillation; however, there is a paucity of data on the relationship between the characteristics of electrograms and the propagation pattern underlying them. In this study, a realistic 3D computer model of the human atria has been developed to investigate this relationship. The model includes a realistic geometry with fiber orientation, anisotropic conductivity and electrophysiological heterogeneity. We simulated different tachyarrhythmic episodes applying both transient and continuous ectopic activity. Electrograms and their dominant frequency and organization index values were calculated over the entire atrial surface. Our simulations show electrograms with simple potentials, with little or no cycle length variations, narrow frequency peaks and high organization index values during stable and regular activity as the observed in atrial flutter, atrial tachycardia (except in areas of conduction block) and in areas closer to ectopic activity during focal atrial fibrillation. By contrast, cycle length variations and polymorphic electrograms with single, double and fragmented potentials were observed in areas of irregular and unstable activity during atrial fibrillation episodes. Our results also show: 1) electrograms with potentials without negative deflection related to spiral or curved wavefronts that pass over the recording point and move away, 2) potentials with a much greater proportion of positive deflection than negative in areas of wave collisions, 3) double potentials related with wave fragmentations or blocking lines and 4) fragmented electrograms associated with pivot points. Our model is the first human atrial model with realistic fiber orientation used to investigate the relationship between different atrial arrhythmic propagation patterns and the electrograms observed at more than 43000 points on the atrial surface. PMID:23408928
Madias, John E
2004-04-01
The author describes his experience with a "saline-filled central venous catheter electrocardiographic lead" for the recording of intracardiac electrocardiograms provides a brief description of the methodology, refers to this modality's clinical usefulness, furnishes 2 examples illustrating the contribution of the method to clinical diagnosis, and outlines his literature search to find the discoverer/originator of the employment of a saline-filled intracardiac catheter as an electrocardiogram recording lead.
Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang
2016-06-01
The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.
Brochet, E; Habib, G
2005-06-01
Intracardiac echocardiography is a new technique based on the use of ultrasonic diagnostic catheters. The most significant current experience has been obtained with the AcuNav catheter, with a "phased array" high frequency (5.5 to 10 mHz) detector, which obtains bidimensional echocardiographic views, coupled to pulsed and colour Doppler. Image acquisition is made from an intracardiac position, usually the right atrium. This review touches on the technical aspects of this method, applied to the examination of the intra-atrial septum, as well as the results currently obtained during inter-atrial communication and patent foramen ovale closure procedures. In effect it is in this field of application that intracardiac ultrasound has now found its niche, providing equivalent information to the reference technique of transoesophageal echocardiography. Intracardiac echocardiography allows complete examination of the inter-atrial septum and septal defects, as well as accurate surveillance of the positioning of percutaneous closure devices. An important advantage of intracardiac echocardiography is the possibility of avoiding a general anaesthetic, usually necessary with the transoesophageal route. At present, the main limiting factor to its systematic use is its high cost, linked to the single use catheters.
Sanroman-Junquera, Margarita; Mora-Jimenez, Inmaculada; Garcia-Alberola, Arcadio; Caamano, Antonio J; Trenor, Beatriz; Rojo-Alvarez, Jose L
2018-04-01
Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysiological studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms.
Di Marco, Luigi Yuri; Raine, Daniel; Bourke, John P; Langley, Philip
2013-09-01
Successful termination of atrial fibrillation (AF) during catheter ablation (CA) is associated with arrhythmia-free follow-up. Preablation factors such as mean atrial fibrillation cycle length (AFCL) predict the likelihood of AF termination during ablation but recurring patterns and AFCL stability have not been evaluated. To investigate novel predictors of acute and postoperative ablation outcomes from intracardiac electrograms: (1) recurring AFCL patterns and (2) localization index (LI) of the instantaneous fibrillatory rate distribution. Sixty-two patients with AF (32 paroxysmal AF; 45 men; age 57 ± 10 years) referred for CA were enrolled. One-minute electrogram was recorded from coronary sinus (CS; 5 bipoles) and right atrial appendage (HRA; 2 bipoles). Atrial activations were detected automatically to derive the AFCL and instantaneous fibrillatory rate (inverse of AFCL) time series. Recurring AFCL patterns were quantified by using recurrence plot indices (RPIs): percentage determinism, entropy of determinism, and maximum diagonal length. AFCL stability was determined by using the LI. The CA outcome predictivity of individual indices was assessed. Patients with terminated atrial fibrillation (T-AF) had higher RPI (P < .05 in CS7-8) and LI than did those with nonterminated atrial fibrillation (P < .005 in CS3-4; P < .05 in CS5-6, CS7-8, and HRA). Patients free of arrhythmia after 3-month follow-up had higher RPI and LI (all P < .05 in CS7-8). All indices except percentage determinism predicted T-AF in CS7-8 (area under the curve [AUC] ≥ 0.71; odds ratio [OR] ≥ 4.50; P < .05). The median AFCL and LI predicted T-AF in HRAD (AUC ≥ 0.75; OR ≥ 7.76; P < .05). The RPI and LI predicted 3-month follow-up in CS7-8 (AUC ≥ 0.68; OR ≥ 4.17; P < .05). AFCL recurrence and stability indices could be used in selecting patients more likely to benefit from CA. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Roguin, Ariel; Zviman, Menekhem M.; Meininger, Glenn R.; Rodrigues, E. Rene; Dickfeld, Timm M.; Bluemke, David A.; Lardo, Albert; Berger, Ronald D.; Calkins, Hugh; Halperin, Henry R.
2011-01-01
Background MRI has unparalleled soft-tissue imaging capabilities. The presence of devices such as pacemakers and implantable cardioverter/defibrillators (ICDs), however, is historically considered a contraindication to MRI. These devices are now smaller, with less magnetic material and improved electromagnetic interference protection. Our aim was to determine whether these modern systems can be used in an MR environment. Methods and Results We tested in vitro and in vivo lead heating, device function, force acting on the device, and image distortion at 1.5 T. Clinical MR protocols and in vivo measurements yielded temperature changes <0.5°C. Older (manufactured before 2000) ICDs were damaged by the MR scans. Newer ICD systems and most pacemakers, however, were not. The maximal force acting on newer devices was <100 g. Modern (manufactured after 2000) ICD systems were implanted in dogs (n=18), and after 4 weeks, 3- to 4-hour MR scans were performed (n=15). No device dysfunction occurred. The images were of high quality with distortion dependent on the scan sequence and plane. Pacing threshold and intracardiac electrogram amplitude were unchanged over the 8 weeks, except in 1 animal that, after MRI, had a transient (<12 hours) capture failure. Pathological data of the scanned animals revealed very limited necrosis or fibrosis at the tip of the lead area, which was not different from controls (n=3) not subjected to MRI. Conclusions These data suggest that certain modern pacemaker and ICD systems may indeed be MRI safe. This may have major clinical implications for current imaging practices. PMID:15277324
Electrogram morphology recurrence patterns during atrial fibrillation.
Ng, Jason; Gordon, David; Passman, Rod S; Knight, Bradley P; Arora, Rishi; Goldberger, Jeffrey J
2014-11-01
Traditional mapping of atrial fibrillation (AF) is limited by changing electrogram morphologies and variable cycle lengths. We tested the hypothesis that morphology recurrence plot analysis would identify sites of stable and repeatable electrogram morphology patterns. AF electrograms recorded from left atrial (LA) and right atrial (RA) sites in 19 patients (10 men; mean age 59 ± 10 years) before AF ablation were analyzed. Morphology recurrence plots for each electrogram recording were created by cross-correlation of each automatically detected activation with every other activation in the recording. A recurrence percentage, the percentage of the most common morphology, and the mean cycle length of activations with the most recurrent morphology were computed. The morphology recurrence plots commonly showed checkerboard patterns of alternating high and low cross-correlation values, indicating periodic recurrences in morphologies. The mean recurrence percentage for all sites and all patients was 38 ± 25%. The highest recurrence percentage per patient averaged 83 ± 17%. The highest recurrence percentage was located in the RA in 5 patients and in the LA in 14 patients. Patients with sites of shortest mean cycle length of activations with the most recurrent morphology in the LA and RA had ablation failure rates of 25% and 100%, respectively (hazard ratio 4.95; P = .05). A new technique to characterize electrogram morphology recurrence demonstrated that there is a distribution of sites with high and low repeatability of electrogram morphologies. Sites with rapid activation of highly repetitive morphology patterns may be critical to sustaining AF. Further testing of this approach to map and ablate AF sources is warranted. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Hunter, Ross J; Diab, Ihab; Thomas, Glyn; Duncan, Edward; Abrams, Dominic; Dhinoja, Mehul; Sporton, Simon; Earley, Mark J; Schilling, Richard J
2009-12-01
We tested application of a grading system describing complex fractionated electrograms (CFE) in atrial fibrillation (AF) and used it to validate automated CFE detection (AUTO). Ten seconds bipolar electrograms were classified by visual inspection (VI) during ablation of persistent AF and the result compared with offline manual measurement (MM) by a second blinded operator: Grade 1 uninterrupted fractionated activity (defined as segments > or =70 ms) for > or =70% of recording and uninterrupted > or =1 s; Grade 2 interrupted fractionated activity > or =70% of recording; Grade 3 intermittent fractionated activity 30-70%; Grade 4 discrete (<70 ms) complex electrogram (> or =5 direction changes); Grade 5 discrete simple electrograms (< or =4 direction changes); Grade 6 scar. Grade by VI and MM for 100 electrograms agreed in 89%. Five hundred electrograms were graded on Carto and NavX by VI to validate AUTO in (i) detection of CFE (grades 1-4 considered CFE), and (ii) assessing degree of fractionation by correlating grade and score by AUTO (data shown as sensitivity, specificity, r): NavX 'CFE mean' 92%, 91%, 0.56; Carto 'interval confidence level' using factory settings 89%, 62%, -0.72, and other published settings 80%, 74%, -0.65; Carto 'shortest confidence interval' 74%, 70%, 0.43; Carto 'average confidence interval' 86%, 66%, 0.53. Grading CFE by VI is accurate and correlates with AUTO.
Weiss, Eric H.; Merchant, Faisal M.; d’Avila, Andre; Foley, Lori; Reddy, Vivek Y.; Singh, Jagmeet P.; Mela, Theofanie; Ruskin, Jeremy N.; Armoundas, Antonis A.
2011-01-01
Background Electrical alternans is a pattern of variation in the shape of electrocardiographic waveform that occurs every other beat. In humans, alternation in ventricular repolarization, known as repolarization alternans (RA), has been associated with increased vulnerability to ventricular tachycardia/fibrillation and sudden cardiac death. Methods and Results This study investigates the spatio-temporal variability of intracardiac RA and its relationship to body surface RA in an acute myocardial ischemia model in swine. We developed a real-time multi-channel repolarization signal acquisition, display and analysis system to record electrocardiographic signals from catheters in the right ventricle, coronary sinus, left ventricle, and epicardial surface prior to and following circumflex coronary artery balloon occlusion. We found that RA is detectable within 4 minutes following the onset ischemia, and is most prominently seen during the first half of the repolarization interval. Ischemia-induced RA was detectable on unipolar and bipolar leads (both in near- and far-field configurations) and on body surface leads. Far-field bipolar intracardiac leads were more sensitive for RA detection than body surface leads, with the probability of body surface RA detection increasing as the number of intracardiac leads detecting RA increased, approaching 100% when at least three intracardiac leads detected RA. We developed a novel, clinically-applicable intracardiac lead system based on a triangular arrangement of leads spanning the right ventricular (RV) and coronary sinus (CS) catheters which provided the highest sensitivity for intracardiac RA detection when compared to any other far-field bipolar sensing configurations (p < 0.0001). Conclusions In conclusion, intracardiac alternans, a complex spatio-temporal phenomenon associated with arrhythmia susceptibility and sudden cardiac death, can be reliably detected through a novel triangular RV-CS lead configuration. PMID:21430127
Electrogram fractionation in murine HL-1 atrial monolayer model.
Umapathy, Karthikeyan; Masse, Stephane; Kolodziejska, Karolina; Veenhuyzen, George D; Chauhan, Vijay S; Husain, Mansoor; Farid, Talha; Downar, Eugene; Sevaptsidis, Elias; Nanthakumar, Kumaraswamy
2008-07-01
Complex fractionated atrial electrograms have been suggested as important targets for catheter ablation of atrial fibrillation. The etiology and the mechanism of these signals have not been completely elucidated because of limitations of interpretation of these signals in relation to simultaneously acquired signals in the neighboring atrial tissue. This study sought to study the origin of electrogram fractionation under the conditions of rotor formation and wave fragmentation, using atrial monolayer preparations. We performed optical mapping of 45 atrial monolayer preparations using a complementary metal oxide semiconductor (CMOS) Brainvision Ultima camera system (SciMedia-Brainvision, Tokyo, Japan). We observed stable rotors in 32 of the 45 recordings. The derived bipolar electrograms did not show complex fractionation at the core of the rotor in any of the 32 recordings. We were also able to show that 2 bipolar electrodes placed adjacent to the core of a stable rotor in a zone where there is no wave break will record electrical activity for the majority of the rotor's cycle length. In 13 of the 45 recordings, wave break or wave collision events were present. Of these, 8 of 13 recordings showed complex fractionation. In 19 of the 27, simulation of meandering rotors also showed complex fractionation. Complex fractionated electrograms can be recorded at sites of migrating rotors and wave break. No fractionation occurs at the core of a stable rotor. Electrograms that span the rotor cycle length and alternate between 2 bipoles that straddle the core can identify site of a stable rotor.
Hillis, L D; Winniford, M D; Jackson, J A; Firth, B G
1985-01-01
Of the various techniques that are available to assess the presence and magnitude of intracardiac shunting, oximetry and indicator dilution are used most frequently. This study was performed to compare these methods in adult patients with pure left-to-right intracardiac shunting. In 27 patients [12 men, 15 women, aged 32 +/- 12 (mean +/- SD) years], shunt magnitude was assessed in close temporal proximity by both techniques. The oximetric percentage left-to-right shunt averaged 55 +/- 16%, whereas the indocyanine green dye percentage shunt was significantly less (36 +/- 14%, p less than 0.001). The oximetric percentage shunt exceeded the indocyanine green dye percentage shunt in 26 and did so by greater than 20% in 23 patients. Thus, there is a substantial difference in shunt magnitude between the oximetric and the indicator dilution techniques. In infants, indicator dilution yields results that are larger than those obtained with the oximetric method. Conversely, in adults, the indicator dilution technique gives results that are consistently smaller than those obtained with oximetry. As a result, the decision regarding therapy of an intracardiac shunt should be made with this in mind.
Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P
1995-01-01
Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval < or = 50 ms, electrogram stability (left-sided targets only), retrograde accessory pathway potential (right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.
Ugarte, Juan P; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John
2014-01-01
There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping.
Ugarte, Juan P.; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John
2014-01-01
There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping. PMID:25489858
Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F
2010-03-01
Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P < .001), but there was substantial overlap with pace capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential ablation line correlates with entrance block in 95% of vein pairs and can be achieved without circular mapping catheter guidance. Thus, pace capture along the ablation line can be used to identify conduction gaps. Interestingly, more RF ablation energy was required to achieve loss of pace capture along the ablation line than for entrance block into PVs. Further study is warranted to determine whether this method results in more durable ablation lesions that reduce recurrence of AF. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Spectral analysis of epicardial 60-lead electrograms in dogs with 4-week-old myocardial infarction.
Hosoya, Y; Ikeda, K; Komatsu, T; Yamaki, M; Kubota, I
2001-01-01
There were few studies on the spectral analysis of multiple-lead epicardial electrograms in chronic myocardial infarction. Spectral analysis of multi-lead epicardial electrograms was performed in 6 sham-operated dogs (N group) and 8 dogs with 4-week-old myocardial infarction (MI group). Four weeks after the ligation of left anterior descending coronary artery, fast Fourier transform was performed on 60-lead epicardial electrograms, and then inverse transform was performed on 5 frequency ranges from 0 to 250 Hz. From the QRS onset to QRS offset, the time integration of unsigned value of reconstructed waveform was calculated and displayed as AQRS maps. On 0-25 Hz AQRS map, there was no significant difference between the 2 groups. In the frequency ranges of 25-250 Hz, MI group had significantly smaller AQRS values than N group solely in the infarct zone. It was shown that high frequency potentials (25-250 Hz) within QRS complex were reduced in the infarct zone.
Talygin, E A; Zazybo, N A; Zhorzholiany, S T; Krestinich, I M; Mironov, A A; Kiknadze, G I; Bokerya, L A; Gorodkov, A Y; Makarenko, V N; Alexandrova, S A
2016-01-01
New approach to intracardiac blood flow condition analysis based on geometric parameters of left ventricle flow channel has been suggested. Parameters, that used in this method, follow from exact solutions of nonstationary Navier-Stocks equations for selforganized tornado-like flows of viscous incompressible fluid. The main advantage of this method is considering dynamic anatomy of intracardiac cavity and trabeculae relief of left ventricle streamlined surface, both registered in a common mri-process, as flow condition indicator. Calculated quantity options that characterizes blood flow condition can be use as diagnostic criterias for estimation of violation in blood circulation function which entails heart ejection reduction. Developed approach allows to clarify heart jet organization mechanism and estimate the share of the tornado-like flow self-organization in heart ejection structure.
Rotor meandering contributes to irregularity in electrograms during atrial fibrillation.
Zlochiver, Sharon; Yamazaki, Masatoshi; Kalifa, Jérôme; Berenfeld, Omer
2008-06-01
Radiofrequency ablation therapy of atrial fibrillation (AF) recently incorporated the analysis of dominant frequency (DF) and/or electrogram fractionation for guidance. However, the relationships between DF, fractionation, and spatiotemporal characteristics of the AF source remain unclear. We hypothesize that a meandering reentrant AF source contributes to the wave fractionation and is reflected in the power spectrum of local electrograms elsewhere in the rotor's surroundings. Meandering rotors as AF sources were simulated in 2-dimensional models of human atrial tissue and recorded in isolated sheep hearts. Nondominant elements of the signals were differentiated from the dominant elements using singular value decomposition, whereby the purely periodic constituent (PC) relating to the rotor's DF was eliminated rendering a residual constituent (RC) that consisted of all other activity. Spectral analysis of the decomposed constituents revealed peaks corresponding to the meandering frequency of the rotor tip, the magnitudes of which were proportional to the size of and the distance to the rotor core. Similar analyses on epicardial optical signals and electrograms from isolated sheep hearts, as well as human complex fractionated atrial electrograms, showed applicability of the approach. Increased meandering of the rotor driving AF reduces activation periodicity and increases fractionation. The spectral manifestation of the rotor activity beyond the meandering region makes it possible to characterize AF source stability, as well as DF in humans using electrode mapping.
Benharash, Peyman; Buch, Eric; Frank, Paul; Share, Michael; Tung, Roderick; Shivkumar, Kalyanam; Mandapati, Ravi
2015-01-01
Background New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. Methods and Results All FIRM-guided ablation procedures (n=24; 50% paroxysmal) at University of California, Los Angeles Medical Center were included for analysis. During AF, unipolar atrial electrograms collected from a 64-pole basket catheter were used to construct phase maps and identify putative AF sources. These sites were targeted for ablation, in conjunction with pulmonary vein isolation in most patients (n=19; 79%). All patients had rotors identified (mean, 2.3±0.9 per patient; 72% in left atrium). Prespecified acute procedural end point was achieved in 12 of 24 (50%) patients: AF termination (n=1), organization (n=3), or >10% slowing of AF cycle length (n=8). Basket electrodes were within 1 cm of 54% of left atrial surface area, and a mean of 31 electrodes per patient showed interpretable atrial electrograms. Offline analysis revealed no differences between rotor and distant sites in dominant frequency or Shannon entropy. Electroanatomic mapping showed no rotational activation at FIRM-identified rotor sites in 23 of 24 patients (96%). Conclusions FIRM-identified rotor sites did not exhibit quantitative atrial electrogram characteristics expected from rotors and did not differ quantitatively from surrounding tissue. Catheter ablation at these sites, in conjunction with pulmonary vein isolation, resulted in AF termination or organization in a minority of patients (4/24; 17%). Further validation of this approach is necessary. PMID:25873718
van Gelder, Berry M; Meijer, Albert; Bracke, Frank A
2008-09-01
We compared the calculated optimal V-V interval derived from intracardiac electrograms (IEGM) with the optimized V-V interval determined by invasive measurement of LVdP/dt(MAX). Thirty-two patients with heart failure (six females, ages 68 +/- 7.8 years) had a CRT device implanted. After implantation of the atrial, right and a left ventricular lead, the optimal V-V interval was calculated using the QuickOpt formula (St. Jude Medical, Sylmar, CA, USA) applied to the respective IEGM recordings (V-V(IEGM)), and also determined by invasive measurement of LVdP/dt(MAX) (V-V(dP/dt)). The optimal V-V(IEGM) and V-V(dP/dt) intervals were 52.7 +/- 18 ms and 24.0 +/- 33 ms, respectively (P = 0.017), without correlation between the two. The baseline LVdP/dt(MAX) was 748 +/- 191 mmHg/s. The mean value of LVdP/dt(MAX) at invasive optimization was 947 +/- 198 mmHg/s, and at the calculated optimal V-V(IEGM) interval 920 +/- 191 mmHg/s (P < 0.0001). In spite of this significant difference, there was a good correlation between both methods (R = 0.991, P < 0.0001). However, a similarly good correlation existed between the maximum value of LVdP/dt(MAX) and LVdP/dt(MAX) at a fixed V-V interval of 0 ms (R = 0.993, P < 0.0001), or LVdP/dt(MAX) at a randomly selected V-V interval between 0 and +80 ms (R = 0.991, P < 0.0001). Optimizing the V-V interval with the IEGM method does not yield better hemodynamic results than simultaneous BiV pacing. Although a good correlation between LVdP/dt(MAX) determined with V-V(IEGM) and V-V(dP/dt) can be constructed, there is no correlation with the optimal settings of V-V interval in the individual patient.
McFadden, Michael S; Bennett, R Avery; Reavill, Drury R; Ragetly, Guillaume R; Clark-Price, Stuart C
2011-09-15
To assess the clinical differences between induction of anesthesia in ball pythons with intracardiac administration of propofol and induction with isoflurane in oxygen and to assess the histologic findings over time in hearts following intracardiac administration of propofol. Prospective randomized study. 30 hatchling ball pythons (Python regius). Anesthesia was induced with intracardiac administration of propofol (10 mg/kg [4.5 mg/lb]) in 18 ball pythons and with 5% isoflurane in oxygen in 12 ball pythons. Induction time, time of anesthesia, and recovery time were recorded. Hearts from snakes receiving intracardiac administration of propofol were evaluated histologically 3, 7, 14, 30, and 60 days following propofol administration. Induction time with intracardiac administration of propofol was significantly shorter than induction time with 5% isoflurane in oxygen. No significant differences were found in total anesthesia time. Recovery following intracardiac administration of propofol was significantly longer than recovery following induction of anesthesia with isoflurane in oxygen. Heart tissue evaluated histologically at 3, 7, and 14 days following intracardiac administration of propofol had mild inflammatory changes, and no histopathologic lesions were seen 30 and 60 days following propofol administration. Intracardiac injection of propofol in snakes is safe and provides a rapid induction of anesthesia but leads to prolonged recovery, compared with that following induction with isoflurane. Histopathologic lesions in heart tissues following intracardiac injection of propofol were mild and resolved after 14 days.
Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja
2017-08-01
Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance <10 mm and fat thickness <1.0 mm were analyzed for voltage and abnormal (fragmented/late potential) electrogram characteristics. At sites with endocardial BV >1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV <1.50 mV was 3.9 mV (area under the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV <1.50 mV, and the remaining could be identified by corresponding low endocardial UV <3.7 mV. For identification of epicardial right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.
Dockery, Douglas W.; Luttmann-Gibson, Heike; Rich, David Q.; Link, Mark S.; Mittleman, Murray A.; Gold, Diane R.; Koutrakis, Petros; Schwartz, Joel D.; Verrier, Richard L.
2005-01-01
Epidemiologic studies have demonstrated a consistent link between sudden cardiac deaths and particulate air pollution. We used implanted cardioverter defibrillator (ICD) records of ventricular tachyarrhythmias to assess the role of air pollution as a trigger of these potentially life-threatening events. The study cohort consisted of 203 cardiac patients with ICD devices in the Boston metropolitan area who were followed for an average of 3.1 years between 1995 and 2002. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured on almost all days, and black carbon, sulfate, and particle number on a subset of days. Date, time, and intracardiac electrograms of ICD-detected arrhythmias were downloaded at the patients’ regular follow-up visits (about every 3 months). Ventricular tachyarrhythmias were identified by electrophysiologist review. Risk of ventricular arrhythmias associated with air pollution was estimated with logistic regression, adjusting for season, temperature, relative humidity, day of the week, patient, and a recent prior arrhythmia. We found increased risks of ventricular arrhythmias associated with 2-day mean exposure for all air pollutants considered, although these associations were not statistically significant. We found statistically significant associations between air pollution and ventricular arrhythmias for episodes within 3 days of a previous arrhythmia. The associations of ventricular tachyarrhythmias with fine particle mass, carbon monoxide, nitrogen dioxide, and black carbon suggest a link with motor vehicle pollutants. The associations with sulfate suggest a link with stationary fossil fuel combustion sources. PMID:15929887
Almeida, Tiago P; Chu, Gavin S; Li, Xin; Dastagir, Nawshin; Tuan, Jiun H; Stafford, Peter J; Schlindwein, Fernando S; Ng, G André
2017-01-01
Purpose: Complex fractionated atrial electrograms (CFAE)-guided ablation after pulmonary vein isolation (PVI) has been used for persistent atrial fibrillation (persAF) therapy. This strategy has shown suboptimal outcomes due to, among other factors, undetected changes in the atrial tissue following PVI. In the present work, we investigate CFAE distribution before and after PVI in patients with persAF using a multivariate statistical model. Methods: 207 pairs of atrial electrograms (AEGs) were collected before and after PVI respectively, from corresponding LA regions in 18 persAF patients. Twelve attributes were measured from the AEGs, before and after PVI. Statistical models based on multivariate analysis of variance (MANOVA) and linear discriminant analysis (LDA) have been used to characterize the atrial regions and AEGs. Results: PVI significantly reduced CFAEs in the LA (70 vs. 40%; P < 0.0001). Four types of LA regions were identified, based on the AEGs characteristics: (i) fractionated before PVI that remained fractionated after PVI (31% of the collected points); (ii) fractionated that converted to normal (39%); (iii) normal prior to PVI that became fractionated (9%) and; (iv) normal that remained normal (21%). Individually, the attributes failed to distinguish these LA regions, but multivariate statistical models were effective in their discrimination ( P < 0.0001). Conclusion: Our results have unveiled that there are LA regions resistant to PVI, while others are affected by it. Although, traditional methods were unable to identify these different regions, the proposed multivariate statistical model discriminated LA regions resistant to PVI from those affected by it without prior ablation information.
Porras, Antonio R; Piella, Gemma; Berruezo, Antonio; Hoogendoorn, Corne; Andreu, David; Fernandez-Armenta, Juan; Sitges, Marta; Frangi, Alejandro F
2013-05-01
Scar presence and its characteristics play a fundamental role in several cardiac pathologies. To accurately define the extent and location of the scar is essential for a successful ventricular tachycardia ablation procedure. Nowadays, a set of widely accepted electrical voltage thresholds applied to local electrograms recorded are used intraoperatively to locate the scar. Information about cardiac mechanics could be considered to characterize tissues with different viability properties. We propose a novel method to estimate endocardial motion from data obtained with an electroanatomical mapping system together with the endocardial geometry segmented from preoperative 3-D magnetic resonance images, using a statistical atlas constructed with bilinear models. The method was validated using synthetic data generated from ultrasound images of nine volunteers and was then applied to seven ventricular tachycardia patients. Maximum bipolar voltages, commonly used to intraoperatively locate scar tissue, were compared to endocardial wall displacement and strain for all the patients. The results show that the proposed method allows endocardial motion and strain estimation and that areas with low-voltage electrograms also present low strain values.
Behçet's Disease and Intracardiac Thrombosis: A Report of Three Cases
Düzgün, Nurşen; Küçükşahin, Orhan; Atasoy, Kayhan Çetin; Togay Işıkay, Canan; Gerede, Demet Menekşe; Erden, Ayşe; Şahap, Seda Kaynak; İbiş, Muhammed Arif; Ateş, Aşkın
2013-01-01
We present three patients with Behçet's disease associated with intracardiac thrombus and pulmonary vascular involvement. One of these patients had also Budd-Chiari syndrome. All patients were treated with corticosteroid plus monthly intravenous cyclophosphamide as first line treatment and with no recurrences. Immunosuppressive therapy was successful in the treatment of intracardiac thrombus and also in the regression of pulmonary vascular thromboses in these patients. Intracardiac thrombus in Behçet's disease is rarely seen. Behçet's disease should be remembered in the differential diagnosis of the patients with intracardiac mass, especially in patients from the Mediterranean and Middle East populations. PMID:23936717
A new transform for the analysis of complex fractionated atrial electrograms
2011-01-01
Background Representation of independent biophysical sources using Fourier analysis can be inefficient because the basis is sinusoidal and general. When complex fractionated atrial electrograms (CFAE) are acquired during atrial fibrillation (AF), the electrogram morphology depends on the mix of distinct nonsinusoidal generators. Identification of these generators using efficient methods of representation and comparison would be useful for targeting catheter ablation sites to prevent arrhythmia reinduction. Method A data-driven basis and transform is described which utilizes the ensemble average of signal segments to identify and distinguish CFAE morphologic components and frequencies. Calculation of the dominant frequency (DF) of actual CFAE, and identification of simulated independent generator frequencies and morphologies embedded in CFAE, is done using a total of 216 recordings from 10 paroxysmal and 10 persistent AF patients. The transform is tested versus Fourier analysis to detect spectral components in the presence of phase noise and interference. Correspondence is shown between ensemble basis vectors of highest power and corresponding synthetic drivers embedded in CFAE. Results The ensemble basis is orthogonal, and efficient for representation of CFAE components as compared with Fourier analysis (p ≤ 0.002). When three synthetic drivers with additive phase noise and interference were decomposed, the top three peaks in the ensemble power spectrum corresponded to the driver frequencies more closely as compared with top Fourier power spectrum peaks (p ≤ 0.005). The synthesized drivers with phase noise and interference were extractable from their corresponding ensemble basis with a mean error of less than 10%. Conclusions The new transform is able to efficiently identify CFAE features using DF calculation and by discerning morphologic differences. Unlike the Fourier transform method, it does not distort CFAE signals prior to analysis, and is relatively robust to jitter in periodic events. Thus the ensemble method can provide a useful alternative for quantitative characterization of CFAE during clinical study. PMID:21569421
Selective management of embolized intracardiac missiles.
Gandhi, S K; Marts, B C; Mistry, B M; Brown, J W; Durham, R M; Mazuski, J E
1996-07-01
Intracardiac projectiles are occasionally found in stable patients who have sustained penetrating trauma. These missiles may arise from embolization from a peripheral injury site. We describe 3 patients with embolized intracardiac projectiles. The diagnosis was suggested by the presence of a foreign body within the cardiac silhouette on chest roentgenograms and was confirmed using fluoroscopy, echocardiography, or computed tomography. The management of embolized intracardiac missiles should be individualized to each patient. All of our patients had fixed intracavitary right-sided missiles and were successfully managed expectantly.
21 CFR 870.4430 - Cardiopulmonary bypass intracardiac suction control.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass intracardiac suction control. 870.4430 Section 870.4430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4430 Cardiopulmonary bypass intracardiac suction control. (a) Identification. A cardiopulmonary bypass...
21 CFR 870.4430 - Cardiopulmonary bypass intracardiac suction control.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass intracardiac suction control. 870.4430 Section 870.4430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4430 Cardiopulmonary bypass intracardiac suction control. (a) Identification. A cardiopulmonary bypass...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M
1995-01-01
Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.
Behavior of an Automatic Pacemaker Sensing Algorithm for Single-Pass VDD Atrial Electrograms
2001-10-25
830- s lead (Medico), during several different body postures, deep respiration, and walking. The algorithm had a pre - determined sensing dynamic range...SINGLE-PASS VDD ATRIAL ELECTROGRAMS J. Kim1, S.H. Lee1, S.Y.Yang2, B. S . Cho2, and W. Huh1 1Department of Electronics Engineering, Myongji...University, Yongin, Korea 2Department of Information and Communication, Dongwon College, Kwangju, Korea S T = 5 0 % x ( B + C ) / 2 S T = 5 0 % x ( A + B
Neic, Aurel; Campos, Fernando O; Prassl, Anton J; Niederer, Steven A; Bishop, Martin J; Vigmond, Edward J; Plank, Gernot
2017-10-01
Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames. In this study we report on the development of a novel computationally efficient reaction-eikonal (R-E) model for modeling extracellular potential maps and electrograms. Using a biventricular human electrophysiology model, which incorporates a topologically realistic His-Purkinje system (HPS), we demonstrate by comparing against a high-resolution reaction-diffusion (R-D) bidomain model that the R-E model predicts extracellular potential fields, electrograms as well as ECGs at the body surface with high fidelity and offers vast computational savings greater than three orders of magnitude. Due to their efficiency R-E models are ideally suitable for forward simulations in clinical modeling studies which attempt to personalize electrophysiological model features.
NASA Astrophysics Data System (ADS)
Neic, Aurel; Campos, Fernando O.; Prassl, Anton J.; Niederer, Steven A.; Bishop, Martin J.; Vigmond, Edward J.; Plank, Gernot
2017-10-01
Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames. In this study we report on the development of a novel computationally efficient reaction-eikonal (R-E) model for modeling extracellular potential maps and electrograms. Using a biventricular human electrophysiology model, which incorporates a topologically realistic His-Purkinje system (HPS), we demonstrate by comparing against a high-resolution reaction-diffusion (R-D) bidomain model that the R-E model predicts extracellular potential fields, electrograms as well as ECGs at the body surface with high fidelity and offers vast computational savings greater than three orders of magnitude. Due to their efficiency R-E models are ideally suitable for forward simulations in clinical modeling studies which attempt to personalize electrophysiological model features.
Balaji, Seshadri; Daga, Ankana; Bradley, David J; Etheridge, Susan P; Law, Ian H; Batra, Anjan S; Sanatani, Shubayan; Singh, Anoop K; Gajewski, Kelly K; Tsao, Sabrina; Singh, Harinder R; Tisma-Dupanovic, Svjetlana; Tateno, Shigeru; Takamuro, Motoki; Nakajima, Hiromichi; Roos-Hesselink, Jolien W; Shah, Maully
2014-08-01
The study objective was to determine whether the extracardiac conduit Fontan confers an arrhythmia advantage over the intracardiac lateral tunnel Fontan. This multicenter study of 1271 patients compared bradyarrhythmia (defined as need for pacing) and tachyarrhythmia (defined as needing antiarrhythmic therapy) between 602 patients undergoing the intracardiac Fontan and 669 patients undergoing the extracardiac Fontan. The median age at the time of the Fontan procedure was 2.1 years (interquartile range, 1.6-3.2 years) for the intracardiac group and 3.0 years (interquartile range, 2.4-3.9) for the extracardiac group (P < .0001). The median follow-up was 9.2 years (interquartile range, 5-12.8) for the intracardiac group and 4.7 years (interquartile range, 2.8-7.7) for the extracardiac group (P < .0001). Early postoperative (<30 days) bradyarrhythmia occurred in 24 patients (4%) in the intracardiac group and 73 patients (11%) in the extracardiac group (P < .0001). Early postoperative (<30 days) tachyarrhythmia occurred in 32 patients (5%) in the intracardiac group and 53 patients (8%) in the extracardiac group (P = not significant). Late (>30 days) bradyarrhythmia occurred in 105 patients (18%) in the intracardiac group and 63 patients (9%) in the extracardiac group (P < .0001). Late (>30 days) tachyarrhythmia occurred in 58 patients (10%) in the intracardiac group and 23 patients (3%) in the extracardiac group (P < .0001). By multivariate analysis factoring time since surgery, more patients in the extracardiac group had early bradycardia (odds ratio, 2.9; 95% confidence interval, 1.8-4.6), with no difference in early tachycardia, late bradycardia, or late tachycardia. Overall arrhythmia burden is similar between the 2 groups, but the extracardiac Fontan group had a higher incidence of early bradyarrhythmias. There was no difference in the incidence of late tachyarrhythmias over time between the 2 operations. Therefore, the type of Fontan performed should be based on factors other than an anticipated reduction in arrhythmia burden from the extracardiac conduit. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Linte, Cristian A; Moore, John; Wedlake, Chris; Bainbridge, Daniel; Guiraudon, Gérard M; Jones, Douglas L; Peters, Terry M
2009-03-01
An interventional system for minimally invasive cardiac surgery was developed for therapy delivery inside the beating heart, in absence of direct vision. A system was developed to provide a virtual reality (VR) environment that integrates pre-operative imaging, real-time intra-operative guidance using 2D trans-esophageal ultrasound, and models of the surgical tools tracked using a magnetic tracking system. Detailed 3D dynamic cardiac models were synthesized from high-resolution pre-operative MR data and registered within the intra-operative imaging environment. The feature-based registration technique was employed to fuse pre- and intra-operative data during in vivo intracardiac procedures on porcine subjects. This method was found to be suitable for in vivo applications as it relies on easily identifiable landmarks, and hence, it ensures satisfactory alignment of pre- and intra-operative anatomy in the region of interest (4.8 mm RMS alignment accuracy) within the VR environment. Our initial experience in translating this work to guide intracardiac interventions, such as mitral valve implantation and atrial septal defect repair demonstrated feasibility of the methods. Surgical guidance in the absence of direct vision and with no exposure to ionizing radiation was achieved, so our virtual environment constitutes a feasible candidate for performing various off-pump intracardiac interventions.
Survey of euthanasia practices in animal shelters in Canada
Caffrey, Niamh; Mounchili, Aboubakar; McConkey, Sandra; Cockram, Michael S.
2011-01-01
Questionnaires on methods of euthanasia used in Canadian animal shelters were sent to 196 Canadian animal shelters yielding 67 responses. Sodium pentobarbital injection was the only method of euthanasia used by 61% of establishments that euthanized dogs and 53% of the establishments that euthanized cats. Many of these establishments used pre-medication. Sodium pentobarbital was mostly administered intravenously but some establishments also used intracardiac and intraperitoneal routes, and some only used intracardiac administration for cats. T-61 injection was the only method of euthanasia used by 23% of the establishments that euthanized dogs and 35% of the establishments that euthanized cats. All of these establishments used pre-medication, but the percentages of establishments that only used the intravenous route for administration of T-61 in dogs and cats were 45% and 7%, respectively. Further studies on the use of T-61, and the training and provision of counselling services for staff are recommended. PMID:21461208
Survey of euthanasia practices in animal shelters in Canada.
Caffrey, Niamh; Mounchili, Aboubakar; McConkey, Sandra; Cockram, Michael S
2011-01-01
Questionnaires on methods of euthanasia used in Canadian animal shelters were sent to 196 Canadian animal shelters yielding 67 responses. Sodium pentobarbital injection was the only method of euthanasia used by 61% of establishments that euthanized dogs and 53% of the establishments that euthanized cats. Many of these establishments used pre-medication. Sodium pentobarbital was mostly administered intravenously but some establishments also used intracardiac and intraperitoneal routes, and some only used intracardiac administration for cats. T-61 injection was the only method of euthanasia used by 23% of the establishments that euthanized dogs and 35% of the establishments that euthanized cats. All of these establishments used pre-medication, but the percentages of establishments that only used the intravenous route for administration of T-61 in dogs and cats were 45% and 7%, respectively. Further studies on the use of T-61, and the training and provision of counselling services for staff are recommended.
Spiral waves characterization: Implications for an automated cardiodynamic tissue characterization.
Alagoz, Celal; Cohen, Andrew R; Frisch, Daniel R; Tunç, Birkan; Phatharodom, Saran; Guez, Allon
2018-07-01
Spiral waves are phenomena observed in cardiac tissue especially during fibrillatory activities. Spiral waves are revealed through in-vivo and in-vitro studies using high density mapping that requires special experimental setup. Also, in-silico spiral wave analysis and classification is performed using membrane potentials from entire tissue. In this study, we report a characterization approach that identifies spiral wave behaviors using intracardiac electrogram (EGM) readings obtained with commonly used multipolar diagnostic catheters that perform localized but high-resolution readings. Specifically, the algorithm is designed to distinguish between stationary, meandering, and break-up rotors. The clustering and classification algorithms are tested on simulated data produced using a phenomenological 2D model of cardiac propagation. For EGM measurements, unipolar-bipolar EGM readings from various locations on tissue using two catheter types are modeled. The distance measure between spiral behaviors are assessed using normalized compression distance (NCD), an information theoretical distance. NCD is a universal metric in the sense it is solely based on compressibility of dataset and not requiring feature extraction. We also introduce normalized FFT distance (NFFTD) where compressibility is replaced with a FFT parameter. Overall, outstanding clustering performance was achieved across varying EGM reading configurations. We found that effectiveness in distinguishing was superior in case of NCD than NFFTD. We demonstrated that distinct spiral activity identification on a behaviorally heterogeneous tissue is also possible. This report demonstrates a theoretical validation of clustering and classification approaches that provide an automated mapping from EGM signals to assessment of spiral wave behaviors and hence offers a potential mapping and analysis framework for cardiac tissue wavefront propagation patterns. Copyright © 2018 Elsevier B.V. All rights reserved.
An algorithm for verifying biventricular capture based on evoked-response morphology.
Diotallevi, Paolo; Ravazzi, Pier Antonio; Gostoli, Enrico; De Marchi, Giuseppe; Militello, Carmelo; Kraetschmer, Hannes
2005-01-01
Cardiac resynchronization therapy relies on consistent beat-by-beat myocardial capture in both ventricles. A pacemaker ensuring right (RV) and left ventricular (LV) capture through reliable capture verification and automatic output adjustment would contribute to patients' safety and quality of life. We studied the feasibility of an algorithm based on evoked-response (ER) morphology for capture verification in both the ventricles. RV and LV ER signals were recorded in 20 patients (mean age 72.5 years, range 64.3-80.4 years, 4 females and 16 males) during implantation of biventricular (BiV) pacing systems. Leads of several manufacturers were tested. Pacing and intracardiac electrogram (IEGM) recording were performed using an external pulse generator. IEGM and surface-lead electrocardiogram (ECG) signals were recorded under different pacing conditions for 10 seconds each: RV pacing only, LV pacing only, and BiV pacing with several interventricular delays. Based on morphology characteristics, ERs were classified manually for capture and failure to capture, and the validity of the classification was assessed by reference to the ECG. A total of 3,401 LV- and 3,345 RV-paced events were examined. In the RV and LV, the sensitivities of the algorithm were 95.6% and 96.1% in the RV and LV, respectively, and the corresponding specificities were 91.4% and 95.2%, respectively. The lower sensitivity in the RV was attributed to signal blanking in both channels during BiV pacing with a nonzero interventricular delay. The analysis revealed that the algorithm for identifying capture and failure to capture based on the ER-signal morphology was safe and effective in each ventricle with all leads tested in the study.
Chang, Gwo-Jyh; Chang, Chi-Jen; Chen, Wei-Jan; Yeh, Yung-Hsin; Lee, Hsiao-Yu
2013-02-28
Caffeic acid phenethyl ester (CAPE) is an active component of propolis that exhibits cardioprotective and antiarrhythmic effects. The detailed mechanisms underlying these effects, however, are not entirely understood. The aim of this study was to elucidate the electromechanical effects of CAPE in guinea-pig cardiac preparations. Intracardiac electrograms, left ventricular (LV) pressure, and the anti-arrhythmic efficacy were determined using isolated hearts. Action potentials of papillary muscles were assessed with microelectrodes, Ca(2+) transients were measured by fluorescence, and ion fluxes were measured by patch-clamp techniques. In a perfused heart model, CAPE prolonged the atrio-ventricular conduction interval, the Wenckebach cycle length, and the refractory periods of the AV node and His-Purkinje system, while shortening the QT interval. CAPE reduced the occurrence of reperfusion-induced ventricular fibrillation and decreased LV pressure in isolated hearts. In papillary muscles, CAPE shortened the action potential duration and reduced both the maximum upstroke velocity and contractile force. In fura-2-loaded single ventricular myocytes, CAPE decreased cell shortening and the Ca(2+) transient amplitude. Patch-clamp experiments revealed that CAPE produced a use-dependent decrease in L-type Ca(2+) current (ICa,L) (IC50=1.1 μM) and Na(+) current (INa) (IC50=0.43 μM), caused a negative-shift of the voltage-dependent inactivation and a delay of recovery from inactivation. CAPE decreased the delayed outward K(+) current (IK) slightly, without affecting the inward rectifier K(+) current (IK1). These results suggest that the preferential inhibition of Ca(2+) inward and Na(+) inward currents by CAPE may induce major electromechanical alterations in guinea-pig cardiac preparations, which may underlie its antiarrhythmic action. Copyright © 2013 Elsevier B.V. All rights reserved.
Luck, Christian; DeMarco, Vincent G; Mahmood, Abuzar; Gavini, Madhavi P; Pulakat, Lakshmi
2017-01-01
Diabetes is comorbid with cardiovascular disease and impaired immunity. Rapamycin improves cardiac functions and extends lifespan by inhibiting the mechanistic target of rapamycin complex 1 (mTORC1). However, in diabetic murine models, Rapamycin elevates hyperglycemia and reduces longevity. Since Rapamycin is an immunosuppressant, we examined whether Rapamycin (750 μ g/kg/day) modulates intracardiac cytokines, which affect the cardiac immune response, and cardiac function in male lean (ZL) and diabetic obese Zucker (ZO) rats. Rapamycin suppressed levels of fasting triglycerides, insulin, and uric acid in ZO but increased glucose. Although Rapamycin improved multiple diastolic parameters ( E / E ', E '/ A ', E / Vp ) initially, these improvements were reversed or absent in ZO at the end of treatment, despite suppression of cardiac fibrosis and phosphoSer473Akt. Intracardiac cytokine protein profiling and Ingenuity® Pathway Analysis indicated suppression of intracardiac immune defense in ZO, in response to Rapamycin treatment in both ZO and ZL. Rapamycin increased fibrosis in ZL without increasing phosphoSer473Akt and differentially modulated anti-fibrotic IL-10, IFN γ , and GM-CSF in ZL and ZO. Therefore, fundamental difference in intracardiac host defense between diabetic ZO and healthy ZL, combined with differential regulation of intracardiac cytokines by Rapamycin in ZO and ZL hearts, underlies differential cardiac outcomes of Rapamycin treatment in health and diabetes.
Luck, Christian; DeMarco, Vincent G.; Mahmood, Abuzar; Gavini, Madhavi P.
2017-01-01
Diabetes is comorbid with cardiovascular disease and impaired immunity. Rapamycin improves cardiac functions and extends lifespan by inhibiting the mechanistic target of rapamycin complex 1 (mTORC1). However, in diabetic murine models, Rapamycin elevates hyperglycemia and reduces longevity. Since Rapamycin is an immunosuppressant, we examined whether Rapamycin (750 μg/kg/day) modulates intracardiac cytokines, which affect the cardiac immune response, and cardiac function in male lean (ZL) and diabetic obese Zucker (ZO) rats. Rapamycin suppressed levels of fasting triglycerides, insulin, and uric acid in ZO but increased glucose. Although Rapamycin improved multiple diastolic parameters (E/E′, E′/A′, E/Vp) initially, these improvements were reversed or absent in ZO at the end of treatment, despite suppression of cardiac fibrosis and phosphoSer473Akt. Intracardiac cytokine protein profiling and Ingenuity® Pathway Analysis indicated suppression of intracardiac immune defense in ZO, in response to Rapamycin treatment in both ZO and ZL. Rapamycin increased fibrosis in ZL without increasing phosphoSer473Akt and differentially modulated anti-fibrotic IL-10, IFNγ, and GM-CSF in ZL and ZO. Therefore, fundamental difference in intracardiac host defense between diabetic ZO and healthy ZL, combined with differential regulation of intracardiac cytokines by Rapamycin in ZO and ZL hearts, underlies differential cardiac outcomes of Rapamycin treatment in health and diabetes. PMID:28408970
Rafael, Aldo Elmer; Keshavamurthy, Suresh; Sepulveda, Edgardo; Miranda, Cyndee Cruz; Okamoto, Toshihiro; Pettersson, Gosta Bengt
2014-06-01
Cutaneous fistula as a clinical presentation of intracardiac abscess of the right side is such an unusual occurrence that it has not until now been reported in the English-language medical literature. We present a rare case of right-sided infective endocarditis caused by Achromobacter xylosoxidans in which recurrent infection presented as sternal wound discharge. The infection was found to have an intracardiac origin and was successfully managed by radical débridement on cardiopulmonary bypass.
Keshavamurthy, Suresh; Sepulveda, Edgardo; Miranda, Cyndee Cruz; Okamoto, Toshihiro; Pettersson, Gosta Bengt
2014-01-01
Cutaneous fistula as a clinical presentation of intracardiac abscess of the right side is such an unusual occurrence that it has not until now been reported in the English-language medical literature. We present a rare case of right-sided infective endocarditis caused by Achromobacter xylosoxidans in which recurrent infection presented as sternal wound discharge. The infection was found to have an intracardiac origin and was successfully managed by radical débridement on cardiopulmonary bypass. PMID:24955054
Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N
2017-06-01
Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.
Ikeda, Atsushi; Nakagawa, Hiroshi; Lambert, Hendrik; Shah, Dipen C; Fonck, Edouard; Yulzari, Aude; Sharma, Tushar; Pitha, Jan V; Lazzara, Ralph; Jackman, Warren M
2014-12-01
Electrode-tissue contact force (CF) is believed to be a major factor in radiofrequency lesion size. The purpose of this study was to determine, in the beating canine heart, the relationship between CF and radiofrequency lesion size and the accuracy of predicting CF and lesion size by measuring electrogram amplitude, impedance, and electrode temperature. Eight dogs were studied closed chest. Using a 7F catheter with a 3.5 mm irrigated electrode and CF sensor (TactiCath, St. Jude Medical), radiofrequency applications were delivered to 3 separate sites in the right ventricle (30 W, 60 seconds, 17 mL/min irrigation) and 3 sites in the left ventricle (40 W, 60 seconds, 30 mL/min irrigation) at (1) low CF (median 8 g); (2) moderate CF (median 21 g); and (3) high CF (median 60 g). Dogs were euthanized and lesion size was measured. At constant radiofrequency and time, lesion size increased significantly with increasing CF (P<0.01). The incidence of a steam pop increased with both increasing CF and higher power. Peak electrode temperature correlated poorly with lesion size. The decrease in impedance during the radiofrequency application correlated well with lesion size for lesions in the left ventricle but less well for lesions in the right ventricle. There was a poor relationship between CF and the amplitude of the bipolar or unipolar ventricular electrogram, unipolar injury current, and impedance. Radiofrequencylesion size and the incidence of steam pop increase strikingly with increasing CF. Electrogram parameters and initial impedance are poor predictors of CF for radiofrequency ablation. © 2014 American Heart Association, Inc.
Bortone, Agustín; Brault-Noble, Guillaume; Appetiti, Anthony; Marijon, Eloi
2015-08-01
It has been experimentally shown that elimination of the negative component of the unipolar atrial electrogram (R morphology completion) during radiofrequency applications reflects transmural lesions creation. Subsequently, it has been clinically suggested that such a transmurality can be either irreversible or reversible. The present study is aimed to determine, at the histological level, whether transmural lesions, assessed by R morphology completion, might indeed be reversible in some circumstances or not. In 6 Mongrel hound dogs, superior and inferior vena cavae were isolated and individual lesions were created in the right atrium using radiofrequency energy (30 W/48°C/17 mL/min as presettings and 10g of force in average) under CARTO guidance. Five types of lesions were created; R+0: termination of ablation at the time of R morphology completion; R+5, R+10, or R+20: extension of ablation for 5, 10, or 20 seconds, respectively, after R morphology achievement; and conventional: radiofrequency applications lasting 30 seconds irrespective of the atrial electrogram modification. All conventional, R+5, R+10, and R+20 lesions were necrotic and transmural, whereas some R+0 lesions were not (comprising a part of necrosis and a part of reversible cell damage). Interestingly, surrounding organ injuries were observed after conventional, R+10, and R+20 radiofrequency applications but were not observed after R+0 and R+5 applications. Elimination of the negative component of the unipolar atrial electrogram reflects, in general, irreversible transmural necrosis creation. In some cases, however, it translates transmural lesion only (with potential reversibility) likely related to transient cell damage creation. © 2015 American Heart Association, Inc.
Challenges and Implementation of Radiation-Force Imaging with an Intracardiac Ultrasound Transducer
Hsu, Stephen J.; Fahey, Brian J.; Dumont, Douglas M.; Wolf, Patrick D.; Trahey, Gregg E.
2010-01-01
Intracardiac echocardiography (ICE) has been demonstrated to be an effective imaging modality for the guidance of several cardiac procedures, including radiofrequency ablation (RFA). However, assessing lesion size during the ablation with conventional ultrasound has been limited, as the associated changes within the B-mode images often are subtle. Acoustic radiation force impulse (ARFI) imaging is a promising modality to monitor RFAs as it is capable of visualizing variations in local stiffnesses within the myocardium. We demonstrate ARFI imaging with an intracardiac probe that creates higher quality images of the developing lesion. We evaluated the performance of an ICE probe with ARFI imaging in monitoring RFAs. The intracardiac probe was used to create high contrast, high resolution ARFI images of a tissue-mimicking phantom containing stiffer spherical inclusions. The probe also was used to examine an excised segment of an ovine right ventricle with a RFA-created surface lesion. Although the lesion was not visible in conventional B-mode images, the ARFI images were able to show the boundaries between the lesion and the surrounding tissue. ARFI imaging with an intracardiac probe then was used to monitor cardiac ablations in vivo. RFAs were performed within the right atrium of an ovine heart, and B-mode and ARFI imaging with the intracardiac probe was used to monitor the developing lesions. Although there was little indication of a developing lesion within the B-mode images, the corresponding ARFI images displayed regions around the ablation site that displaced less. PMID:17523564
Ulloa-Ricardez, Alfredo; Romero-Espinoza, Lizett; Estrada-Loza, María de Jesús; González-Cabello, Héctor Jaime; Núñez-Enríquez, Juan Carlos
2016-08-01
Central venous catheter (CVC) installation is essential for the treatment of critically ill neonates; however, it is associated with the development of neonatal intracardiac thrombosis, which is a complication that is associated with a poor prognosis. We aimed to identify specific risk factors for the development of intracardiac thrombosis in the right atrium (RA) and superior vena cava (SVC) related to the use of CVC in critically ill neonates. A case-control study was conducted at the tertiary referral neonatal intensive care unit of the Pediatric Hospital Siglo XXI in Mexico City, Mexico from 2008 to 2013. The included cases (n = 43) were de novo patients with intracardiac thrombosis in the RA and SVC diagnosed by echocardiography. The controls (n = 43) were neonates without intracardiac thrombosis or thrombosis at other sites. A logistic regression analysis was conducted, and odds ratios (ORs) and 95% confidence intervals (95% CIs) were calculated. The independent risk factors for intracardiac thrombosis in the RA and SVC were the surgical cut-down insertion technique (OR = 2.98; 95% CI: 1.18-9.10), a maternal history of gestational diabetes/diabetes mellitus (OR = 10.64; 95% CI: 1.13-121.41), Staphylococcus epidermidis infection (OR = 7.09; 95% CI: 1.09-45.92), and CVC placement in the SVC (OR = 5.77; 95% CI: 1.10-30.18). This study allowed us to identify several contributing factors to the development of intracardiac thrombosis in the RA and SVC related to the installation of a CVC in a subgroup of critically ill neonates. Multicenter and well-designed studies with a larger number of patients could help validate our findings and/or identify other risk factors that were not identified in the present study. Copyright © 2015. Published by Elsevier B.V.
Elective correction of intracardiac lesions resulting from penetrating wounds of the heart.
Morgan, S; Maturana, G; Urzua, J; Franck, R; Dubernet, J
1979-01-01
Controversy exists regarding the timing and technique of total correction of traumatic intracardiac lesions. Five patients with penetrating wounds of the heart received emergency treatment aimed at securing normal haemodynamics. No attempt was made to identify intracardiac lesions at this stage. Cineangiography two months to seven years later showed aorto-right ventricular fistulae in all patients, associated in two with aortic cusp laceration and in one with an aorto-left atrial fistula. The surgical approach for aorto-right ventricular fistula was through the right ventricle or aorta. Valvar injuries were treated by plastic reconstruction. All patients showed good clinical results when seen four to 11 years later. Traumatic intracardiac lesions in patients with stable haemodynamics after initial treatment should be operated on electively. The aortic approach is preferable for aorto-right ventricular fistulae. Conservative plastic repair of valvar injuries achieves long-term competence thus avoiding prosthetic replacement. PMID:505341
Joo, Jung-Chul; Seol, Myung Do; Yoon, Jin Won; Lee, Young Soo; Kim, Dong-Keun; Choi, Yong Hoon; Ahn, Hyo Seong; Cho, Wook Hyun
2013-03-01
Myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) is a multisystem clinical syndrome manifested by mitochondrial myopathy, encephalopathy, lactic acidosis and recurrent stroke-like episodes. A 27-year-old female with MELAS syndrome presented with cerebral infarction. Echocardiography revealed a thrombus attached to the apex of the hypertrophied left ventricle, with decreased systolic function. The embolism of the intracardiac thrombus might have been the cause of stroke. There should be more consideration given to the increased possibility of intracardiac thrombus formation when a MELAS patient with cardiac involvement is encountered.
Rababah, A S; Walsh, S J; Manoharan, G; Walsh, P R; Escalona, O J
2016-07-01
Intracardiac impedance (ICI) is a major determinant of success during internal cardioversion of atrial fibrillation (AF). However, there have been few studies that have examined the dynamic behaviour of atrial impedance during internal cardioversion in relation to clinical outcome. In this study, voltage and current waveforms captured during internal cardioversion of acute AF in ovine models using novel radiofrequency (RF) generated low-tilt rectilinear and conventional capacitor-discharge based shock waveforms were retrospectively analysed using a digital signal processing algorithm to investigate the dynamic behaviour of atrial impedance during cardioversion. The algorithm was specifically designed to facilitate the simultaneous analysis of multiple impedance parameters, including: mean intracardiac impedance (Z M), intracardiac impedance variance (ICIV) and impedance amplitude spectrum area (IAMSA) for each cardioversion event. A significant reduction in ICI was observed when comparing two successive shocks of increasing energy where cardioversion outcome was successful. In addition, ICIV and IAMSA variables were found to inversely correlate to the magnitude of energy delivered; with a stronger correlation found to the former parameter. In conclusion, ICIV and IAMSA have been evidenced as two key dynamic intracardiac impedance variables that may prove useful in better understanding of the cardioversion process and that could potentially act as prognostic markers with respect to clinical outcome.
Disruption of intracardiac flow patterns in the newborn infant.
Groves, Alan M; Durighel, Giuliana; Finnemore, Anna; Tusor, Nora; Merchant, Nazakat; Razavi, Reza; Hajnal, Jo V; Edwards, A David
2012-04-01
Consistent patterns of rotational intracardiac flow have been demonstrated in the healthy adult human heart. Intracardiac rotational flow patterns are hypothesized to assist in the maintenance of kinetic energy of inflowing blood, augmenting cardiac function. Newborn cardiac function is known to be suboptimal secondary to decreased receptor number and sympathetic innervation, increased afterload, and increased reliance on atrial contraction to support ventricular filling. Patterns of intracardiac flow in the newborn have not previously been examined. Whereas 5 of the 13 infants studied showed significant evidence of rotational flow within the right atrium, 8 infants showed little or no rotational flow. Presence or absence of rotational flow was not related to gestational age, birth weight, postnatal age, atrial size, or image quality. Despite absence of intra-atrial rotational flow, atrioventricular valve flow into the left and right ventricles later in the cardiac cycle could be seen, suggesting that visualization techniques were adequate. While further study is required to assess its exact consequences on cardiac mechanics and energetics, disruption to intracardiac flow patterns could be another contributor to the multifactorial sequence that produces newborn circulatory failure. We studied 13 newborn infants, using three-dimensional (3D) cardiac magnetic resonance phase-contrast imaging (spatial resolution 0.84 mm, temporal resolution 22.6 ms) performed without sedation/anesthesia.
Linton, Nick; O'Neill, Louisa; Harrison, James; Whitaker, John; Mukherjee, Rahul; Rinaldi, Christopher A.; Gill, Jaswinder; Niederer, Steven; Wright, Matthew; O'Neill, Mark
2017-01-01
Abstract Introduction Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. Methods and results LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4‐4‐4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak‐to‐peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or <1 mV (22 ± 15%), and voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or <1 mV (13 ± 8%). Electrograms showing bipolar voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P < 0.001). There was a small but significant increase in conduction delay between unipole pairs at sites showing bipolar voltage attenuation (P = 0.026). Conclusions Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate. PMID:28639747
An unusual case of metastatic intracardiac plasmacytoma.
Tak, T; Rashtian, M; De Tar, M; Chandraratna, P A; Gill, P
1994-10-01
The authors report the case of a 36-year-old male who, following investigations for dyspnea, othopnea and peripheral cyanosis, was found to have metastatic intracardiac plasmacytoma. Diagnosis was made initially with transesophageal echocardiography and emergent cardiac surgery was performed. Postoperative transthoracic and transesophageal echocardiograms revealed residual masses in the right and left atrium. The patient was subsequently treated with systemic chemotherapy and was symptom-free within three months of treatment, with rapid decline of paraproteins in the serum and urine. This case of intracardiac metastatic plasmacytoma is deemed unique because cardiac involvement with multiple myeloma has not been studied in detail, largely due to the rarity of such a presentation.
Fischer, Harald; Harper, Alexander A; Anderson, Colin R; Adams, David J
2005-01-01
The effects of γ-aminobutyric acid (GABA) on the electrophysiological properties of intracardiac neurones were investigated in the intracardiac ganglion plexus in situ and in dissociated neurones from neonatal, juvenile and adult rat hearts. Focal application of GABA evoked a depolarizing, excitatory response in both intact and dissociated intracardiac ganglion neurones. Under voltage clamp, both GABA and muscimol elicited inward currents at −60 mV in a concentration-dependent manner. The fast, desensitizing currents were mimicked by the GABAA receptor agonists muscimol and taurine, and inhibited by the GABAA receptor antagonists, bicuculline and picrotoxin. The GABAA0 antagonist (1,2,5,6-tetrahydropyridin-4-yl)methyl phosphonic acid (TPMPA), had no effect on GABA-induced currents, suggesting that GABAA receptor-channels mediate the response. The GABA-evoked current amplitude recorded from dissociated neurones was age dependent whereby the peak current density measured at −100 mV was ∼ 20 times higher for intracardiac neurones obtained from neonatal rats (P2–5) compared with adult rats (P45–49). The decrease in GABA sensitivity occurred during the first two postnatal weeks and coincides with maturation of the sympathetic innervation of the rat heart. Immunohistochemical staining using antibodies against GABA demonstrate the presence of GABA in the intracardiac ganglion plexus of the neonatal rat heart. Taken together, these results suggest that GABA and taurine may act as modulators of neurotransmission and cardiac function in the developing mammalian intrinsic cardiac nervous system. PMID:15731187
A rare but serious manifestation of Behçet's disease: intracardiac thrombus in 22 patients.
Emmungil, Hakan; Yaşar Bilge, N Şule; Küçükşahin, Orhan; Kılıç, Levent; Okutucu, Sercan; Gücenmez, Sercan; Kalyoncu, Umut; Kaşifoğlu, Timuçin; Turgay, Murat; Aksu, Kenan
2014-01-01
Behçet's disease (BD) is a chronic, multisystemic disorder characterised by recurrent oral aphtous ulcers, genital ulcers and ocular inflammation. Vasculitis and thrombotic events are the most important causes of mortality. Vena cava thrombosis, pulmonary artery aneurysms, Budd-Chiari syndrome, peripheral artery aneurysms, dural sinus thrombosis and abdominal aorta aneurysms are the other less common vascular manifestations of BD. Cardiac involvement in BD is a rare and life-threatening complication. The aim of this study was to assess the clinical characteristics and outcome of patients with BD who have intracardiac thrombus. The hospital files of BD patients followed by rheumatology clinics of four medical centres (Ankara University, Ege University, Hacettepe University and Eskişehir Osmangazi University Hospitals) were retrospectively evaluated. Data included patients' demographic and clinical features, laboratory findings and outcome. All patients fulfilled three or more of the International Study Group Criteria for BD. Twenty-two patients with intracardiac thrombus were evaluated. The mean age of patients with intracardiac thrombosis was 29.1 yrs (22-44) and there was a male predominance with a ratio of 20:2. Cardiac involvement was the first clinical manifestation of BD in 9 of the 22 patients. Initial symptoms of the patients were fever (n=18, 81%), dyspnea (n=9, 40%) chest pain (n=9, 40%) and haemoptysis (n=7, 31.8%). Sixteen patients (72%) had pulmonary arteritis and 10 (45%) patients had venous system lesions included deep vein, inferior vena cava and hepatic vein. Intra-cardiac thrombus were found only in the right cavities in 17 patients (77%), only in the left cavities in 2 patients (9%), and in both left and right cavities of the heart in 3 patients (13.6%). Once the cardiac lesion was diagnosed as a complication of BD, high dose (1mg/kg/d) prednisone (n=22, 100%) plus cyclophosphamide (n=18, 81%) or azathioprine (n=3, 13.6%) and warfarin (n=8, 36.3% (after the elimination of pulmonary aneurysm) therapy for anticoagulation was initiated. Four patients (18%) had high dose prednisone plus cyclophosphamide plus interferon-α (IFN-α) combination treatment and two patients (n=2, 9%) had high dose prednisone plus cyclophosphamide or plus azathioprine combination treatment. After treatment, the intra-cardiac thrombus disappeared in 13 cases and the size of the thrombus reduced in 7 cases. One patient died because of recurrent intra-cardiac thrombus and massive pulmonary arteritis in the emergency department. Intracardiac thrombus in BD is more common in young men. The right side of the heart is usually involved and cardiac involvement is often accompanied by pulmonary artery occlusion possibly due to pulmonary arteritis. Early and aggressive immunosuppressive and/or anticoagulation therapy are life-saving.
Maesato, Akira; Higa, Satoshi; Lin, Yenn-Jiang; Chinen, Ichiro; Ishigaki, Sugako; Yajima, Machiko; Masuzaki, Hiroaki; Chen, Shih-Ann
2011-01-01
Predictors of T wave oversensing with implantable cardioverter-defibrillator (ICD) systems remains to be clarified. Thirteen consecutive patients who underwent ICD implantations were included. The depolarization (R) and repolarization (T) of bipolar electrograms during baseline, AAI and DDD modes, and an isoproterenol (ISO) infusion were evaluated. The R wave amplitude during DDD was significantly lower as compared to that during the other conditions in all high-pass filter settings. In contrast, there was no significant difference in the T wave amplitude during the DDD as compared to the other conditions. With the DDD, there was a significantly higher incidence of a T/R ratio of greater than 0.25 as compared to that with the other conditions. T wave amplitude in Brugada syndrome was significantly higher than that in non-Brugada syndrome. The existence of Brugada syndrome and T/R ratio during the AAI with a high-pass filter setting of 10/20 Hz was an excellent predictor of T wave oversensing in the follow-up period. DDD had a significant impact on the R wave amplitude reduction and the T/R ratio during AAI can be predictors of T wave oversensing. These findings have important implications for inappropriate shocks due to T wave oversensing.
Wiegand, U K; Zhdanov, A; Stammwitz, E; Crozier, I; Claessens, R J; Meier, J; Bos, R J; Bode, F; Potratz, J
1999-06-01
The aim of this multicenter study was to investigate the performance of a new cardiac pacemaker lead with a titanium nitride cathode coated with a copolymer membrane. In particular, the electrophysiological effect of steroid dissolved in this ion-exchange membrane was evaluated by randomized comparison. Ninety-five patients were randomized either to the 1450 T (n = 51) or the 1451 T ventricular lead (n = 45) and received telemeteral VVI(R) pacemakers with identical diagnostic features. Both leads were bipolar, were passively affixed, and had a porous titanium nitride tip with a surface area of 3.5 mm2. The only difference between the two electrodes was 13 micrograms of dexamethasone added to the 1450 Ts membrane coating. Voltage thresholds (VTH) at pulse durations of 0.25, 0.37, and 0.5 ms, lead impedance, and sensing thresholds were measured at discharge, 2 weeks, 1 month, 3 months, and 6 months after implantation. Mean amplitude and the slew rate from three telemetered intracardiac electrograms, chronaxie-rheobase product, and minimum energy consumption were calculated. After a 6-month follow-up, mean voltage thresholds of 0.65 +/- 0.20 V and 0.63 +/- 0.34 were achieved for the 1450 T lead and 1451 T lead, respectively. As a result, a VTH < 1.0 V was obtained in all patients with 1450 T electrodes and in 97.7% of patients with 1451 T leads after 6 months follow-up. In both electrodes, stable VTH was reached 2 weeks after implantation, and no transient rise in threshold was observed. No differences were observed between the steroid and the nonsteroid group in respect to VTH, chronaxie-rheobase product, minimum energy consumption, and potential amplitude and slew rate. In conclusion, safe and efficient pacing at low pulse amplitudes were achieved with both leads. The tip design, independently of the steroid additive, prevented any energy-consuming increases in the voltage threshold.
Hanon, Sam; Shapiro, Michael; Schweitzer, Paul
2004-07-01
The following article presents an unusual case of atrial tachycardia, initially misdiagnosed due to a lack of clear P waves. The diagnosis was eventually confirmed using the atrial electrogram from the patient's pacemaker.
Effect of body repositioning after venous air embolism. An echocardiographic study
NASA Technical Reports Server (NTRS)
Geissler, H. J.; Allen, S. J.; Mehlhorn, U.; Davis, K. L.; Morris, W. P.; Butler, B. D.
1997-01-01
BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.
Morrison, Jennifer A; Pike, Laura A; Lund, Greg; Zhou, Qiong; Kessler, Brittelle E; Bauerle, Kevin T; Sams, Sharon B; Haugen, Bryan R; Schweppe, Rebecca E
2015-06-01
Thyroid cancer incidence has been increasing over time, and it is estimated that ∼1950 advanced thyroid cancer patients will die of their disease in 2015. To combat this disease, an enhanced understanding of thyroid cancer development and progression as well as the development of efficacious, targeted therapies are needed. In vitro and in vivo studies utilizing thyroid cancer cell lines and animal models are critically important to these research efforts. In this report, we detail our studies with a panel of authenticated human anaplastic and papillary thyroid cancer (ATC and PTC) cell lines engineered to express firefly luciferase in two in vivo murine cancer models-an orthotopic thyroid cancer model as well as an intracardiac injection metastasis model. In these models, primary tumor growth in the orthotopic model and the establishment and growth of metastases in the intracardiac injection model are followed in vivo using an IVIS imaging system. In the orthotopic model, the ATC cell lines 8505C and T238 and the PTC cell lines K1/GLAG-66 and BCPAP had take rates >90 % with final tumor volumes ranging 84-214 mm(3) over 4-5 weeks. In the intracardiac model, metastasis establishment was successful in the ATC cell lines HTh74, HTh7, 8505C, THJ-16T, and Cal62 with take rates ≥70 %. Only one of the PTC cell lines tested (BCPAP) was successful in the intracardiac model with a take rate of 30 %. These data will be beneficial to inform the choice of cell line and model system for the design of future thyroid cancer studies.
Conservative management of retained cardiac missiles: case report and literature review.
Lundy, Jonathan B; Johnson, Eric K; Seery, Jason M; Pham, Tach; Frizzi, James D; Chasen, Arthur B
2009-01-01
Intracardiac foreign bodies may be caused by direct penetrating trauma, embolization from injury to another area of the body, or iatrogenically from fragments of intravascular access devices. Penetrating cardiac trauma commonly presents with a hemodynamically unstable patient necessitating emergent life-saving procedures. Missile embolization to the heart can occur after injury to systemic and pulmonary veins. Central venous access devices may fracture after placement and embolize. Especially in the setting of penetrating cardiac trauma, these intracardiac foreign bodies require expeditious removal. Limited data exist regarding the conservative management of intracardiac material after trauma. We present the case of a 42-year-old male soldier injured in a mortar blast in Iraq who suffered multiple injuries to include a right hemopneumothorax and soft tissue injuries to the chest and both lower extremities that was found to have a 2-cm by 2-mm intracardiac metal fragment. Additional imaging revealed a metallic fragment localized to the interatrial septum. The patient suffered no adverse sequelae from nonoperative management. A review of the world literature regarding the subject of posttraumatic retained cardiac missiles (RCMs) is also included to help future surgeons in the management of this rare entity.
Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David
2009-01-01
A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850
Seo, Chi Hyung; Stephens, Douglas N.; Cannata, Jonathan; Dentinger, Aaron; Lin, Feng; Park, Suhyun; Wildes, Douglas; Thomenius, Kai E.; Chen, Peter; Nguyen, Tho; de La Rama, Alan; Jeong, Jong Seob; Mahajan, Aman; Shivkumar, Kalyanam; Nikoozadeh, Amin; Oralkan, Omer; Truong, Uyen; Sahn, David J.; Khuri-Yakub, Pierre T.; O’Donnell, Matthew
2011-01-01
A method is introduced to monitor cardiac ablative therapy by examining slope changes in the thermal strain curve caused by speed of sound variations with temperature. The sound speed of water-bearing tissue such as cardiac muscle increases with temperature. However, at temperatures above about 50°C, there is no further increase in the sound speed and the temperature coefficient may become slightly negative. For ablation therapy, an irreversible injury to tissue and a complete heart block occurs in the range of 48 to 50°C for a short period in accordance with the well-known Arrhenius equation. Using these two properties, we propose a potential tool to detect the moment when tissue damage occurs by using the reduced slope in the thermal strain curve as a function of heating time. We have illustrated the feasibility of this method initially using porcine myocardium in vitro. The method was further demonstrated in vivo, using a specially equipped ablation tip and an 11-MHz microlinear intracardiac echocardiography (ICE) array mounted on the tip of a catheter. The thermal strain curves showed a plateau, strongly suggesting that the temperature reached at least 50°C. PMID:21768025
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng-Ling, Jan; Hwang, Betau; Lee, P.-C.
Purpose: Accurate evaluation of the size, location and adjacent structure of an atrial septal defect (ASD) is very important in the selection of patients for further management. We directly compared the utility of transthoracic echocardiography, angiocardiography, balloon sizing, and intracardiac ultrasound (ICUS) in the detection of ASD.Methods: Twenty-one children underwent an ICUS study of ASD after routine clinical and laboratory studies. All patients had received transthoracic echocardiography (TTE), cardiac catheterization, cineangiography, and balloon sizing before the ICUS to evaluate the ASD.Results: There was a significant correlation between the ICUS-derived ASD diameter and the other methods (p < 0.001). The balloon-sizingmore » diameter was estimated by the equation: TTE diameter x 1.09 + 3.9 mm. There was a good correlation between the predicted and measured balloon-sizing diameter (r = 0.963; p < 0.001).Conclusion: It is worthwhile spending a few minutes to perform ICUS during cardiac catheterization since it will provide more detailed information on and high resolution images of atrial septal morphology, especially for patients undergoing transcatheter closure by device.« less
Iwaya, F; Tanji, M; Ono, T; Tsuda, A; Hoshino, S
1996-05-01
It is important to find a suitable vascular prosthesis as an intracardiac conduit for a total cavopulmonary connection because of the need for long-term patency. A 7-year-old girl with a double outlet of right ventricle, hypoplastic left ventricle, pulmonary atresia and single atrium with azygos connection underwent a total cavopulmonary connection using a knitted dacron prosthesis impregnated with gelatin (GELSEAL) as an intracardiac conduit. Her postoperative course was uneventful. GELSEAL is soft, easy to hand and effective at preventing blood loss. The conduit is also expected to have long-term patency because of good healing with thin and uniform pseudointimal formation. However, long-term patency especially in the right side of the heart is still unknown. She should be followed with close anticoagulant therapy and careful observation.
A Short History of Cardiac Inspection: A Quest "To See with a Better Eye".
Evans, William N
2015-08-01
Cardiac examination has evolved over centuries. The goal of cardiac evaluation, regardless the era, is to "see" inside the heart to diagnose congenital and acquired intra-cardiac structural and functional abnormalities. This article briefly reviews the history of cardiac examination and discusses contemporary best, evidence-based methods of cardiac inspection.
Wang, Gaopin; Liu, Renguang; Chang, Qinghua; Xu, Zhaolong; Zhang, Yingjie; Pan, Dianzhu
2017-03-15
The micro waveform of His bundle potential can't be recorded beat-to-beat on surface electrocardiogram yet. We have found that the micro-wavelets before QRS complex may be related to atrioventricular conduction system potentials. This study is to explore the possibility of His bundle potential can be noninvasively recorded on surface electrocardiogram. We randomized 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia (exclude overt Wolff-Parkinson-White syndrome) to receive "conventional electrocardiogram" and "new electrocardiogram" before the procedure. His bundle electrogram was collected during the procedure. Comparative analysis of PA s (PA interval recorded on surface electrocardiogram), AH s (AH interval recorded on surface electrocardiogram) and HV s (HV interval recorded on surface electrocardiogram) interval recorded on surface "new electrocardiogram" and PA, AH, HV interval recorded on His bundle electrogram was investigated. There was no difference (P > 0.05) between groups in HV s interval (49.63 ± 6.19 ms) and HV interval (49.35 ± 6.49 ms). Results of correlational analysis found that HV S interval was significantly positively associated with HV interval (r = 0.929; P < 0.01). His bundle potentials can be noninvasively recorded on surface electrocardiogram. Noninvasive His bundle potential tracing might represent a new method for locating the site of atrioventricular block and identifying the origin of a wide QRS complex.
[Multi-channel data collection and visualization system for intramyocardial electrograms].
Kastner, P; Wimmer, W; Hutten, H
2000-11-01
The aim of the project was to develop a multichannel data acquisition system for the recording and visualisation of intramyocardial electrograms (IEGM) from both the spontaneously beating and the artificially paced heart. Signal processing comprises multi-step amplification, filtering (0.05-800 Hz), and AD conversion (12 Bit max. 6.25 kHz). IEGMs can be obtained either in unipolar or bipolar mode. Stimulation of the heart is achieved by an incorporated programmable dual-chamber pacemaker that can be selectively switched to the input channels. A LabView-based graphical user interface permits the programming of all system parameters via a microcontroller, and supports data acquisition and visualisation. The system can be used in animal experiments to monitor the spread of excitation across the heart, to measure propagation velocity, or to measure the impact of drugs and pathological changes on the morphology of IEGMs.
Atrial electrogram interpretation improves after an innovative education program.
Preston, Julie L; Currey, Judy; Considine, Julie
2015-01-01
To avoid adverse patient outcomes from inappropriate treatment, it is recommended that an atrial electrogram (AEG) be recorded whenever atrial arrhythmias develop in patients after cardiac surgery. However, AEGs are not commonly performed because nurses lack knowledge about differentiating atrial rhythms on AEGs. To investigate whether completing a novel online evidence-based education program on interpreting AEGs would improve critical care nurses' AEG interpretation. Specialized critical care nurses were taught about obtaining and interpreting atrial rhythms on AEGs using a 42-minute online mini-movie. AEG interpretation was assessed pre and two and eight weeks post-intervention. AEG interpretation increased two weeks post intervention and was retained at eight weeks. Some participants used this newly acquired knowledge to interpret arrhythmias that were not taught during the education program. Accurate interpretation of AEGs is an easy skill for specialized critical care nurses to learn via an online education program.
On the precision of automated activation time estimation
NASA Technical Reports Server (NTRS)
Kaplan, D. T.; Smith, J. M.; Rosenbaum, D. S.; Cohen, R. J.
1988-01-01
We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.
A shot to the heart: a rare case of cardiac embolization
Elsisi, Islam Fathi Hussein Ali; Kidambi, Ananth
2018-01-01
Summary This is a case report of intracardiac foreign bodies that gained access to the heart by migration from a peripheral vein. The case report describes the diagnostic findings on cardiac imaging and summarizes different approaches to management. Learning points: Appearance of embolized cardiac missiles with reverberation and acoustic shadowing. Role of different imaging modalities in the diagnosis of intracardiac foreign bodies. Indications for surgical or transcatheter retrieval. PMID:29440229
Infective endocarditis: outcome in surviving patients with intracardiac complications.
Mocchegiani, Roberto; Pergolini, Martina; Nataloni, Maura
2007-03-01
The purpose of this study was to assess the outcome of 15 patients who survived infective endocarditis with abscesses and other intracardiac complications. Abscesses were associated with native valve endocarditis in seven patients and prosthetic valve endocarditis in eight patients; fistulas were observed in three patients, and subaortic perforation in three patients. Sensitivity for the detection of abscesses was 42.8% and 92.8% using transthoracic and transoesophageal echocardiography, respectively. Eleven patients underwent surgical treatment with no operative mortality, whereas four patients were only medically treated. During follow-up (mean 8.26 years), two patients died (13%) and six recurrences (five early and one late prosthetic valve endocarditis) required re-intervention for prosthesis dysfunction (40%); an improvement in New York Heart Association class in survivors and no changes in echocardiographic lesions were observed. Infective intracardiac complications do not seem to significantly reduce the overall survival (87%) of patients at long-term follow-up.
Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki
2017-11-01
The reconnection of left atrial-pulmonary vein (LA-PV) conduction after the initial procedure of pulmonary vein (PV) isolation is not rare, and is one of the main cause of atrial fibrillation (AF) recurrence after PV isolation. We investigated feasibility of a new ultrahigh-resolution mapping system using a 64-pole small basket catheter for the identification of LA-PV conduction gaps. This prospective study included 31 consecutive patients (20 with persistent AF) undergoing a second ablation after a PV isolation procedure with LA-PV reconnected conduction at any of the 4 PVs. An LA-PV map was created using the mapping system, and ablation was performed at the estimated gap location. The propagation map identified 54 gaps from 39 ipsilateral PV pairs, requiring manual electrogram reannotation for 23 gaps (43%). Gaps at the anterior and carinal regions of left and right ipsilateral PVs required manual electrogram reannotation more frequently than the other regions. The voltage map could identify the gap only in 19 instances (35%). Electrophysiological properties of the gaps (multiple gaps in the same ipsilateral PVs, conduction time, velocity, width, and length) did not differ between those needing and not needing manual electrogram reannotation. During the gap ablation, either the activation sequence alteration or elimination of PV potentials was observed using a circular catheter placed in the PV, suggesting that all the identified gaps were correct. This new electroanatomic mapping system visualized all the LA-PV gaps in patients undergoing a second AF ablation. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Sadrpour, Shervin A; Srinivasan, Deepa; Bhimani, Ashish A; Lee, Seungyup; Ryu, Kyungmoo; Cakulev, Ivan; Khrestian, Celeen M; Markowitz, Alan H; Waldo, Albert L; Sahadevan, Jayakumar
2015-12-01
Postoperative atrial fibrillation (POAF), new-onset AF after open heart surgery (OHS), is thought to be related to pericarditis. Based on AF studies in the canine sterile pericarditis model, we hypothesized that POAF in patients after OHS may be associated with a rapid, regular rhythm in the left atrium (LA), suggestive of an LA driver maintaining AF. The aim of this study was to test the hypothesis that in patients with POAF, atrial electrograms (AEGs) recorded from at least one of the two carefully selected LA sites would manifest a rapid, regular rhythm with AEGs of short cycle length (CL) and constant morphology, but a selected right atrial (RA) site would manifest AEGs with irregular CLs and variable morphology. In 44 patients undergoing OHS, AEGs recorded from the epicardial surface of the RA, the LA portion of Bachmann's bundle, and the posterior LA during sustained AF were analysed for regularity of CL and morphology. Sustained AF occurred in 15 of 44 patients. Atrial electrograms were recorded in 11 of 15 patients; 8 of 11 had rapid, regular activation with constant morphology recorded from at least one LA site; no regular AEG sites were present in 3 of 11 patients. Atrial electrograms recorded during sustained POAF frequently demonstrated rapid, regular activation in at least one LA site, consistent with a driver maintaining AF. Published by Oxford University Press on behalf of the European Society of Cardiology 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Polewczyk, Anna; Jacheć, Wojciech; Janion, Marianna; Podlaski, Rafał; Kutarski, Andrzej
2015-07-01
Lead-dependent infective endocarditis (LDIE) is a serious and insidious infective disease spreading along the leads to valve leaflets and endocardial surface. LDIE is still a lesser known disease with unclear risk factors, most often evaluated jointly for all infectious complications. Clinical data from 414 patients with the diagnosis of LDIE according to the Modified Duke Leads Criteria were analyzed. Patients with LDIE were identified in a population of 1,426 subjects submitted to transvenous lead extraction (TLE) in the Reference Center on Lead Extraction in Lublin, Poland, between March 2006 and July 2013 due to infectious (619 patients-43.4%) and noninfectious (807-56.6% of patients) reasons. During the period of 2006-2011, the analysis was conducted retrospectively; from early 2012 on, patients were enrolled prospectively. The effect of potential risk factors on the development of the disease was evaluated in a comparative analysis of clinical data from the LDIE patients and from 807 subjects with noninfectious indications for TLE. Additionally, in order to identify the factors predisposing to the development of LDIE, the population of infectious patients was divided into three subgroups: with isolated LDIE (157 patients), with LDIE and pocket infection (PI; 257 patients), and with isolated PI (205 patients). The groups and subgroups were analyzed for the presence of patient-dependent risk factors (age, gender, accompanying diseases, anticoagulation, or antiplatelet therapy) and procedure-related risk factors (the number and lead dwell time, pacing system, prior procedures, lead loops, and intracardiac abrasion of the leads). Furthermore, microbes' identification was conducted. The LDIE patients were older (67.3 vs 62.3; P = 0.001) and were more frequently male (68.6% vs 55.0%; P = 0.001) as compared with patients submitted to TLE for noninfectious reasons, but not in comparison with subjects diagnosed with isolated LDIE. In univariate analysis, the independent prognostic factors of LDIE were: type 2 diabetes-increase of risk by 37.7% (hazard ratio [HR] = 1,377; 95% confidence interval [CI] [1,088-1,742]), elevated above 2 mg% creatinine level-increase of risk by 61.5% (HR = 1,615; 95% CI [1,96-2,182]), antiplatelet therapy (HR = 1,285; 95% CI [1,052-1,057]), number of intracardiac leads prior to TLE (HR = 1,199; 95% CI [1,075-1,337]), intracardiac device with implantable cardioverter defibrillator (ICD) lead (HR = 1,909; 95% CI [1,492-2,444]), intracardiac device with coronary sinus lead (HR = 1,411; 95% CI [1,099-1,810]), number of procedures prior to TLE (HR = 1,092; 95% CI [1,017-1,172]), and abrasion of intracardiac leads (HR = 1,350; 95% CI [1,097-1,662]). Multivariate logistic regression demonstrated that the independent risk factors of LDIE were: chronic renal failure (HR = 1,406; 95% CI [1,033-1,915]), number of intracardiac leads prior to TLE (HR = 1,152; 95% CI [1,017-1,305]), intracardiac devices with ICD leads (HR = 1,719; 95% CI [1,330-2,223]), and presence of abrasion of intracardiac leads (HR = 1,405; 95% CI [1,129-1,750]). Microbiological analysis showed the domination of coagulase-negative staphylococci with relative advantage of Staphylococcus epidermidis in pathogenesis of LDIE. The factors predisposing to LDIE are mainly related to procedures performed on the patients. LDIE develops more frequently in patients with multiple leads, especially ICD. An important, until now lesser known, risk factor for LDIE is intracardiac abrasion of the leads strongly connected with procedural agents and properties of specific kind of bacteries. A new concept of the pathogenesis of LDIE was proposed on the basis of present analysis. ©2015 Wiley Periodicals, Inc.
2012-10-31
intrapulmonary and intracardiac shunt using saline contrast echocardiography to determine bubble/shunt scores. We will also use nuclear medicine imaging to...subjects have completed saline contrast echocardiography while breathing hypoxic gas mixtures. For Task #2 “10 hr hypoxic exposure and AMS... echocardiography while breathing an FIO2=0.14, will be susceptible or resistant to developing AMS after 10 hr hypoxic exposure. For Task #3 “Hypoxia
A systematic surgical approach to hepatoblastoma with intracardiac extension.
Sayed, Sajid; Prabhu, Sudesh; Fawcett, Jonathan; Choo, Kelvin; Alphonso, Nelson
2017-05-01
Hepatoblastoma is very uncommon in children, and intracardiac extension is rare. The SIOPEL-4 regime for metastatic hepatoblastoma has extended the surgical options with good results. We successfully treated a boy aged 2 years and 9 months with hepatoblastoma, using a multidisciplinary surgical strategy involving an extended left hepatectomy, left adrenalectomy, biopsy of the paraaortic and coeliac lymph nodes, and resection of the inferior vena caval-right atrial extension of the hepatoblastoma, under cardiopulmonary bypass and deep hypothermia.
Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing
Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.
2015-01-01
A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948
Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.
Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J
2008-07-01
A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.
Rowland, E; Evans, T; Krikler, D
1979-01-01
Intravenous nifedipine, a powerful calcium antagonist, had no obvious effect on atrioventricular conduction when administered to 11 patients during routine intracardiac electrophysiological studies. Verapamil on the other hand showed potent antiarrhythmic properties, depressing atrioventricular nodal conduction. Nifedipine thus appears safe in patients with angina pectoris who have disorders of atrioventricular nodal conduction, and in those receiving beta-adrenergic blocking drugs. There appear to be differential effects on the slow inward channels of cardiac cells with different 'calcium antagonists'. PMID:486272
Intracardiac heterotopia--mesenchymal and endodermal.
Ariza, S; Rafel, E; Castillo, J A; Garcia-Canton, J A
1978-01-01
A case is reported of an intracardiac 'epithelial heterotopia' with a predominant mesenchymal component. This is thought to have resulted from the differentiation of aberrant primitive cell(s) displaced into the heart during its development. Though microscopically resembling a myxoma, this lesion is clearly distinguished by the presence of glandular structures. The myxoid component exhibited a startling invasiveness which resulted in occlusion of the superior vena cava, causing symptoms very early in life and death at the age of 6 months. Images PMID:637987
Approaches to catheter ablation for persistent atrial fibrillation.
Verma, Atul; Jiang, Chen-yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan
2015-05-07
Catheter ablation is less successful for persistent atrial fibrillation than for paroxysmal atrial fibrillation. Guidelines suggest that adjuvant substrate modification in addition to pulmonary-vein isolation is required in persistent atrial fibrillation. We randomly assigned 589 patients with persistent atrial fibrillation in a 1:4:4 ratio to ablation with pulmonary-vein isolation alone (67 patients), pulmonary-vein isolation plus ablation of electrograms showing complex fractionated activity (263 patients), or pulmonary-vein isolation plus additional linear ablation across the left atrial roof and mitral valve isthmus (259 patients). The duration of follow-up was 18 months. The primary end point was freedom from any documented recurrence of atrial fibrillation lasting longer than 30 seconds after a single ablation procedure. Procedure time was significantly shorter for pulmonary-vein isolation alone than for the other two procedures (P<0.001). After 18 months, 59% of patients assigned to pulmonary-vein isolation alone were free from recurrent atrial fibrillation, as compared with 49% of patients assigned to pulmonary-vein isolation plus complex electrogram ablation and 46% of patients assigned to pulmonary-vein isolation plus linear ablation (P=0.15). There were also no significant differences among the three groups for the secondary end points, including freedom from atrial fibrillation after two ablation procedures and freedom from any atrial arrhythmia. Complications included tamponade (three patients), stroke or transient ischemic attack (three patients), and atrioesophageal fistula (one patient). Among patients with persistent atrial fibrillation, we found no reduction in the rate of recurrent atrial fibrillation when either linear ablation or ablation of complex fractionated electrograms was performed in addition to pulmonary-vein isolation. (Funded by St. Jude Medical; ClinicalTrials.gov number, NCT01203748.).
A novel intra-operative, high-resolution atrial mapping approach.
Yaksh, Ameeta; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Oei, Frans B S; van de Woestijne, Pieter C; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S
2015-12-01
A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.
Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof
2018-03-27
Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.
Lee, Seungyup; Sahadevan, Jayakumar; Khrestian, Celeen M; Cakulev, Ivan; Markowitz, Alan; Waldo, Albert L
2015-12-01
The mechanism(s) of persistent and long-standing persistent (LSP) atrial fibrillation (AF) is/are poorly understood. We performed high-density, simultaneous, biatrial, epicardial mapping of persistent and LSP AF in patients undergoing open heart surgery (1) to test the hypothesis that persistent and LSP AF are due to ≥ 1 drivers, either focal or reentrant, and (2) to characterize associated atrial activation. Twelve patients with persistent and LSP AF (1 month to 9 years duration) were studied at open heart surgery. During AF, electrograms were recorded from both atria simultaneously for 1 to 5 minutes from 510 to 512 epicardial electrodes with ECG lead II. Thirty-two consecutive seconds of activation sequence maps were produced per patient. During AF, multiple foci (QS unipolar atrial electrograms) of different cycle lengths (mean, 175 ± 18 ms) were present in both atria in 11 of 12 patients. Foci (2-4 per patient, duration 5-32 s) were either sustained or intermittent, were predominantly found in the lateral left atrial free wall, and likely acted as drivers. Random and nonrandom breakthrough activation sites (initial r or R in unipolar atrial electrograms) were also found. In 1 of 12 patients, only breakthrough sites were found. All wave fronts emanated from foci and breakthrough sites, and largely either collided or merged with each other at variable sites. Repetitive focal QS activation occasionally generated repetitive wannabe reentrant activation in 5 of 12 patients. No actual reentry was found. During persistent and LSP AF in 12 patients, wave fronts emanating from foci and breakthrough sites maintained AF. No reentry was demonstrated. © 2015 American Heart Association, Inc.
Chik, William W B; Barry, M A; Malchano, Zach; Wylie, Bryan; Pouliopoulos, Jim; Huang, Kaimin; Lu, Juntang; Thavapalachandran, Sujitha; Robinson, David; Saadat, Vahid; Thomas, Stuart P; Ross, David L; Kovoor, Pramesh; Thiagalingam, Aravinda
2012-01-01
Radiofrequency (RF) ablation utilizing direct endocardial visualization (DEV) requires a "virtual electrode" to deliver RF energy while preserving visualization. This study aimed to: (1) examine the virtual electrode RF ablation efficacy; (2) determine the optimal power and duration settings; and (3) evaluate the utility of virtual electrode unipolar electrograms. The DEV catheter lesions were compared to lesions formed using a 3.5 mm open irrigated tip catheter within the right atria of 12 sheep. Generator power settings for DEV were titrated from 12W, 14W and 16W for 20, 30 and 40 seconds duration with 25 mL/min saline irrigation. Standard irrigated tip catheter settings of 30W, 50°C for 30 seconds and 30 mL/min were used. The DEV lesions were significantly greater in surface area and both major and minor axes compared to irrigated tip lesions (surface area 19.43 ± 9.09 vs 10.88 ± 4.72 mm, P<0.01) with no difference in transmurality (93/94 vs 46/47) or depth (1.86 ± 0.75 vs 1.85 ± 0.57 mm). Absolute electrogram amplitude reduction was greater for DEV lesions (1.89 ± 1.31 vs 1.49 ± 0.78 mV, P = 0.04), but no difference in percentage reduction. Pre-ablation pacing thresholds were not different between DEV (0.79 ± 0.36 mA) and irrigated tip (0.73 ± 0.25 mA) lesions. There were no complications noted during ablation with either catheter. Virtual electrode ablation consistently created wider lesions at lower power compared to irrigated tip ablation. Virtual electrode electrograms showed a comparable pacing and sensing efficacy in detecting local myocardial electrophysiological changes. © 2011 Wiley Periodicals, Inc.
Oron, Liron; Bruchim, Yaron; Klainbart, Sigal; Kelmer, Efrat
2017-03-01
To describe the use of an ultrasound-guided intracardiac xenotransfusion of canine packed red blood cells (pRBC) to the left ventricle of a severely anemic cat during cardiopulmonary resuscitation (CPR). An 8-year-old previously healthy neutered female cat was presented with severe weakness after she had disappeared for 1 month. On presentation, the cat was in hypovolemic shock, laterally recumbent, and severely anemic with massive flea infestation. Within minutes of admission, the cat became agonal and suffered cardiopulmonary arrest. CPR was immediately initiated; however, attempts to gain IV access during CPR were unsuccessful. As the cat's blood type was yet unknown, 10 mL of canine pRBC was transfused directly into the left ventricular chamber using ultrasound guidance, as well as 0.02 mg/kg of epinephrine using a similar technique. The cat regained cardiac activity and once the jugular vein was cannulated it received 20 additional mL of canine pRBC intravenously. The packed cell volume and total plasma protein following the intracardiac transfusion were 0.09 L/L [9%] and 30 g/L [3.0 g/dL], respectively. Subsequent blood typing revealed the cat had type B blood. The cat was discharged 3 days post-CPR and was alive and doing well 3 months following discharge. This is the first reported case of ultrasound-guided intracardiac canine-to-feline xenotransfusion during CPR. © Veterinary Emergency and Critical Care Society 2017.
Rao, Liyun; Ling, Yuesheng; He, Renjie; Gilbert, April L; Frangogiannis, Nikolaos G; Wang, Jianwen; Nagueh, Sherif F; Khoury, Dirar S
2008-02-01
Multiple imaging modalities are employed independent of one another while managing complex cardiac arrhythmias. To combine electrical, anatomical, and functional imaging in a single catheter system, we developed a balloon catheter that carried 64 electrodes on its surface and an intracardiac echocardiography (ICE) catheter through a central lumen. The catheter system was inserted, and the balloon was inflated inside the left ventricle (LV) of eight dogs with 6-wk-old infarction, created by occlusion in the left anterior descending coronary artery. Anatomy was constructed by ICE imaging (9 MHz) through the balloon. Single-beat noncontact mapping (NCM) was performed via the multielectrode array to reconstruct unipolar endocardial electrograms during sinus rhythm. Standard contact mapping (CM) of the endocardium was also carried out for reference. Myocardial infarction in anterior LV extending from the middle to apical regions was localized both by ICE and NCM and validated by CM and pathology. The overall difference in the activation times between NCM and CM was 3 +/- 1 ms. Unipolar voltage in infarcted middle anterior LV was smaller than the voltage in normal middle inferior LV both by NCM (11 +/- 4 vs. 16 +/- 3 mV; P = 0.002) and CM (11 +/- 3 vs. 20 +/- 4 mV; P < 0.001). Unipolar voltage was also inversely related to infarct transmurality, both by NCM (r = -0.87; P = 0.005) and CM (r = -0.94; P < 0.001). The infarct area by ICE (7.7 +/- 2.9 cm(2)) was in agreement with CM (bipolar voltage, <1 mV; and area, 7.6 +/- 3.3 cm(2); r = 0.80; P = 0.016). Meanwhile, the voltage threshold that depicted the infarct area by NCM was directly related to the smallest unipolar voltage reconstructed within the infarct (r = 0.96; P < 0.001). In conclusion, combining NCM and ICE imaging in a single catheter system is feasible. The preclinical development of such an integrated system and its evaluation in experimental myocardial infarction demonstrate capabilities for single-beat mapping at multiple sites as well as the online assessment of anatomy and myocardial function.
Dowling, Michael M; Quinn, Charles T; Ramaciotti, Claudio; Kanter, Julie; Osunkwo, Ifeyinwa; Inusa, Baba; Iyer, Rathi; Kwiatkowski, Janet L; Johnson, Clarissa; Rhodes, Melissa; Owen, William; Strouse, John J; Panepinto, Julie A; Neumayr, Lynne; Sarnaik, Sharada; Plumb, Patricia A; Dlamini, Nomazulu; Kirkham, Fenella; Hynan, Linda S
2017-01-01
'Paradoxical' embolization via intracardiac or intrapulmonary right-to-left shunts (RLS) is an established cause of stroke. Hypercoagulable states and increased right heart pressure, which both occur in sickle cell anaemia (SCA), predispose to paradoxical embolization. We hypothesized that children with SCA and overt stroke (SCA + stroke) have an increased prevalence of potential RLS. We performed contrasted transthoracic echocardiograms on 147 children (aged 2-19 years) with SCA + stroke) mean age 12·7 ± 4·8 years, 54·4% male) and a control group without SCA or stroke (n = 123; mean age 12·1 ± 4·9 years, 53·3% male). RLS was defined as any potential RLS detected by any method, including intrapulmonary shunting. Echocardiograms were masked and adjudicated centrally. The prevalence of potential RLS was significantly higher in the SCA+stroke group than controls (45·6% vs. 23·6%, P < 0·001). The odds ratio for potential RLS in the SCA + stroke group was 2·7 (95% confidence interval: 1·6-4·6) vs controls. In post hoc analyses, the SCA + stroke group had a higher prevalence of intrapulmonary (23·8% vs. 5·7%, P < 0·001) but not intracardiac shunting (21·8% vs. 18·7%, P = 0·533). SCA patients with potential RLS were more likely to report headache at stroke onset than those without. Intrapulmonary and intracardiac shunting may be an overlooked, independent and potentially modifiable risk factor for stroke in SCA. © 2016 John Wiley & Sons Ltd.
Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.
Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y
2004-03-01
Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.
Järverud, K; Ollmar, S; Brodin, L A
2002-09-01
Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.
Park, Jin-Sung; Kim, Jaedong; Lee, Yonggu; Gwon, Jun-Gyo; Park, Ye-Soo
2018-05-07
Percutaneous vertebroplasty (PVP) is a minimally invasive surgical treatment for patients with osteoporotic vertebral compression fracture (OVCF) and can rapidly alleviate pain, improve mobility, and stabilize the vertebrae. However, it has the potential to cause complications such as cement embolism. A 55-year-old female presented with pain in the lumbar region as a chief complaint. PVP was performed after diagnosis of acute OVCFs at L4 and L5. No abnormal symptoms were reported after surgery, but a large cement embolism was observed in her right atrium and ventricle. After discussion in a multi-disciplinary team, the large cement embolism was successfully removed by a combination of endovascular procedure and an inferior vena cava exploration. Surgeons must consider the possibility of intra-cardiac cement embolism after PVP. A hybrid approach of an endovascular procedure and a vascular surgery may be a reasonable treatment option to minimize the surgical procedure in cases of a large intra-cardiac cement embolism.
Spatial Resolution Requirements for Accurate Identification of Drivers of Atrial Fibrillation
Roney, Caroline H.; Cantwell, Chris D.; Bayer, Jason D.; Qureshi, Norman A.; Lim, Phang Boon; Tweedy, Jennifer H.; Kanagaratnam, Prapa; Vigmond, Edward J.; Ng, Fu Siong
2017-01-01
Background— Recent studies have demonstrated conflicting mechanisms underlying atrial fibrillation (AF), with the spatial resolution of data often cited as a potential reason for the disagreement. The purpose of this study was to investigate whether the variation in spatial resolution of mapping may lead to misinterpretation of the underlying mechanism in persistent AF. Methods and Results— Simulations of rotors and focal sources were performed to estimate the minimum number of recording points required to correctly identify the underlying AF mechanism. The effects of different data types (action potentials and unipolar or bipolar electrograms) and rotor stability on resolution requirements were investigated. We also determined the ability of clinically used endocardial catheters to identify AF mechanisms using clinically recorded and simulated data. The spatial resolution required for correct identification of rotors and focal sources is a linear function of spatial wavelength (the distance between wavefronts) of the arrhythmia. Rotor localization errors are larger for electrogram data than for action potential data. Stationary rotors are more reliably identified compared with meandering trajectories, for any given spatial resolution. All clinical high-resolution multipolar catheters are of sufficient resolution to accurately detect and track rotors when placed over the rotor core although the low-resolution basket catheter is prone to false detections and may incorrectly identify rotors that are not present. Conclusions— The spatial resolution of AF data can significantly affect the interpretation of the underlying AF mechanism. Therefore, the interpretation of human AF data must be taken in the context of the spatial resolution of the recordings. PMID:28500175
Andrews, Christopher M; Srinivasan, Neil T; Rosmini, Stefania; Bulluck, Heerajnarain; Orini, Michele; Jenkins, Sharon; Pantazis, Antonis; McKenna, William J; Moon, James C; Lambiase, Pier D; Rudy, Yoram
2017-07-01
Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a significant cause of sudden cardiac death in the young. Improved noninvasive assessment of ARVC and better understanding of the disease substrate are important for improving patient outcomes. We studied 20 genotyped ARVC patients with a broad spectrum of disease using electrocardiographic imaging (a method for noninvasive cardiac electrophysiology mapping) and advanced late gadolinium enhancement cardiac magnetic resonance scar imaging. Compared with 20 healthy controls, ARVC patients had longer ventricular activation duration (median, 52 versus 42 ms; P =0.007) and prolonged mean epicardial activation-recovery intervals (a surrogate for local action potential duration; median, 275 versus 241 ms; P =0.014). In these patients, we observed abnormal and varied epicardial activation breakthrough locations and regions of nonuniform conduction and fractionated electrograms. Nonuniform conduction and fractionated electrograms were present in the early concealed phase of ARVC. Electrophysiological abnormalities colocalized with late gadolinium enhancement scar, indicating a relationship with structural disease. Premature ventricular contractions were common in ARVC patients with variable initiation sites in both ventricles. Premature ventricular contraction rate increased with exercise, and within anatomic segments, it correlated with prolonged repolarization, electric markers of scar, and late gadolinium enhancement (all P <0.001). Electrocardiographic imaging reveals electrophysiological substrate properties that differ in ARVC patients compared with healthy controls. A novel mechanistic finding is the presence of repolarization abnormalities in regions where ventricular ectopy originates. The results suggest a potential role for electrocardiographic imaging and late gadolinium enhancement in early diagnosis and noninvasive follow-up of ARVC patients. © 2017 American Heart Association, Inc.
Voltage gradient mapping and electrophysiologically guided cryoablation in children with AVNRT.
Drago, Fabrizio; Battipaglia, Irma; Russo, Mario Salvatore; Remoli, Romolo; Pazzano, Vincenzo; Grifoni, Gino; Allegretti, Greta; Silvetti, Massimo Stefano
2018-04-01
Recently, voltage gradient mapping of Koch's triangle to find low-voltage connections, or 'voltage bridges', corresponding to the anatomic position of the slow pathway, has been introduced as a method to ablate atrioventricular nodal reentry tachycardia (AVNRT) in children. Thus, we aimed to assess the effectiveness of voltage mapping of Koch's triangle, combined with the search for the slow potential signal in 'low-voltage bridges', to guide cryoablation of AVNRT in children. From June 2015 to May 2016, 35 consecutive paediatric patients (mean age 12.1 ± 4.5 years) underwent 3D-guided cryoablation of AVNRT at our Institution. Fifteen children were enrolled as control group (mean age 14 ± 4 years). A voltage gradient mapping of Koch's triangle was obtained in all patients, showing low-voltage connections in all children with AVNRT but not in controls. Prior to performing cryoablation, we looked for the typical 'hump and spike' electrogram, generally considered to be representative of slow pathway potential within a low-voltage bridge. In all patients the 'hump and spike' electrogram was found inside bridges of low voltage. Focal or high-density linear lesions, extended or not, were delivered guided by low-voltage bridge visualization. Acute success rate was 100%, and no recurrence was reported at a mean follow-up of 8 ± 3 months. Voltage gradient mapping of Koch's triangle, combined with the search for the slow potential signal in low-voltage bridges, is effective in guiding cryoablation of AVNRT in paediatric patients, with a complete acute success rate and no AVNRT recurrences at mid-term follow-up.
Papafaklis, M I; Ligthart, J M R; Vaina, S; Witsenburg, M; Bogers, A J J C; Serruys, P W
2005-01-01
In this case report, we present the use of intracardiac echocardiography (ICE) for guiding the cardiac catheterization and subsequent hemodynamic investigation in an unusual patient case with multiple congenital abnormalities (bicuspid aortic valve, left cervical aortic arch, two aortic coarctations) and two aortic valve replacement operations in the past. The ICE catheter (AcuNav) permitted us to accurately and safely puncture the interatrial septum and place the Swan-Ganz catheter in the left ventricle; additionally, visualization of the aortic coarctation in the ascending aorta was also achieved.
Diagnostic dilemma: Intracardiac mass in a woman with Behçet's syndrome.
Núñez-Cabarcas, Edilberto; López-Ruiz, Nilson; Ramírez-Rincón, Alex
2014-01-01
Intracardiac thrombosis is a rare manifestation of cardiac involvement in Behçet's disease, and it may be mistaken for a heart tumor. In this letter we present the case of a patient diagnosed with Behçet's disease who was incidentally found to have a mass in the right atrium suspicious of a cardiac tumor. Nevertheless, cardiac magnetic resonance showed a cardiac thrombus. Immunosuppressive therapy and anticoagulation were effective for thrombus resolution. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
Stopyra, Jason P; Winslow, James E; Fitzgerald, David M; Bozeman, William P
2017-11-01
Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead. Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled. Sterile subcutaneous electrodes were placed at the right sternoclavicular junction and the left lower costal margin at the midclavicular line. A standard police issue TASER Model X26 CEW was attached to the subcutaneous electrodes and a 5 s discharge was delivered. Continuous surface and intracardiac EKG monitoring was performed. A total of 157 subjects were reviewed for possible inclusion and 21 were interviewed. Among these, 4 subjects agreed and completed the study protocol. All subjects tolerated the 5 s CEW discharge without clinical complications. There were no significant changes in mean heart rate or blood pressure. Interrogation of the devices after CEW discharge revealed no ventricular pacing, dysrhythmias, damage or interference with the implanted devices. In this pilot study, we have successfully navigated the regulatory hurdles and demonstrated the feasibility of performing intracardiac EKG recording during intentional precordial CEW discharges in humans. While no CEW-associated dysrhythmias were noted, the size of this preliminary dataset precludes making conclusions about the risk of such events. Larger studies are warranted and should consider exploring variations of the CEW electrode position in relation to the cardiac silhouette. Copyright © 2017. Published by Elsevier Ltd.
Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea
2008-11-01
Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.
Cardiac arrhythmias from a malpositioned Greenfield filter in a traumatic quadriplegic.
Bach, J R; Zaneuski, R; Lee, H
1990-10-01
A case study is presented of premature Greenfield filter discharge with intracardiac migration and resulting life-threatening arrhythmias. These arrhythmias also interfered with the patient's transition from ventilatory support via orotracheal intubation to noninvasive positive airway pressure ventilatory support methods. The patient's arrhythmias were controlled by a demand cardiac pacemaker and cardiac glycoside therapy. No anticoagulants were used. She had no further filter migration nor significant complications for 16 months after hospital discharge.
Lin, Yenn-Jiang; Lo, Men-Tzung; Chang, Shih-Lin; Lo, Li-Wei; Hu, Yu-Feng; Chao, Tze-Fan; Chung, Fa-Po; Liao, Jo-Nan; Lin, Chin-Yu; Kuo, Huan-Yu; Chang, Yi-Chung; Lin, Chen; Tuan, Ta-Chuan; Vincent Young, Hsu-Wen; Suenari, Kazuyoshi; Dan Do, Van Buu; Raharjo, Suunu Budhi; Huang, Norden E; Chen, Shih-Ann
2016-11-01
This prospective study compared the efficacy of atrial substrate modification guided by a nonlinear phase mapping technique with that of conventional substrate ablation. The optimal ablation strategy for persistent atrial fibrillation (AF) was unknown. In phase 1 study, we applied a cellular automation technique to simulate the electrical wave propagation to improve the phase mapping algorithm, involving analysis of high-similarity electrogram regions. In addition, we defined rotors and focal AF sources, using the physical parameters of the divergence and curvature forces. In phase 2 study, we enrolled 68 patients with persistent AF undergoing substrate modification into 2 groups, group-1 (n = 34) underwent similarity index (SI) and phase mapping techniques; group-2 (n = 34) received complex fractionated atrial electrogram ablation with commercially available software. Group-1 received real-time waveform similarity measurements in which a phase mapping algorithm was applied to localize the sources. We evaluated the single-procedure freedom from AF. In group-1, we identified an average of 2.6 ± 0.89 SI regions per chamber. These regions involved rotors and focal sources in 65% and 77% of patients in group-1, respectively. Group-1 patients had shorter ablation procedure times, higher termination rates, and significant reduction in AF recurrence compared to group-2 and a trend toward benefit for all atrial arrhythmias. Multivariate analysis showed that substrate mapping using nonlinear similarity and phase mapping was the independent predictor of freedom from AF recurrence (hazard ratio: 0.26; 95% confidence interval: 0.09 to 0.74; p = 0.01). Our study showed that for persistent AF ablation, a specified substrate modification guided by nonlinear phase mapping could eliminate localized re-entry and non-pulmonary focal sources after pulmonary vein isolation. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Lai, L P; Lin, J L; Lien, W P; Tseng, Y Z; Huang, S K
2000-05-01
This study was undertaken to assess the effects of sotalol on the transthoracic cardioversion energy requirement for chronic atrial fibrillation (AF) and on the atrial electrograms during AF recorded by two basket electrodes. The effects of sotalol infusion on transthoracic electrical cardioversion for chronic atrial fibrillation in humans have not been well investigated. We included 18 patients with persistent AF for more than three months. Atrial electrograms were recorded by two basket electrodes positioned in each atrium respectively. Transthoracic cardioversion was performed before and after sotalol 1.5 mg/kg i.v. infusion. In the 14 patients whose AF could be terminated by cardioversion before sotalol infusion, the atrial defibrillation energy was significantly reduced after sotalol infusion (236 +/- 74 jules [J] vs. 186 +/- 77 J; p < 0.01). Atrial fibrillation was refractory to cardioversion in four patients at baseline and was converted to sinus rhythm by cardioversion after sotalol infusion in two of them. We further divided the patients into two groups. Group A consisted of 10 patients in whom the energy requirement was decreased by sotalol while group B consisted of eight patients in whom the energy requirement was not decreased. The mean A-A (atrial local electrogram) intervals during AF were significantly increased after sotalol infusion in both groups, but the increment of A-A interval was significantly larger in group A than it was in group B patients (36 +/- 13 ms vs. 22 +/- 8 ms for the right atrium; 19 +/- 7 ms vs. 9 +/- 7 ms for the left atrium; both p < 0.05). The spatial and temporal dispersions of A-A intervals were not significantly changed after sotalol infusion in both atria in both groups. Sotalol decreases the atrial defibrillation energy requirement by increasing atrial refractoriness but not by decreasing the dispersion of refractoriness.
Williams, Steven E; Linton, Nick; O'Neill, Louisa; Harrison, James; Whitaker, John; Mukherjee, Rahul; Rinaldi, Christopher A; Gill, Jaswinder; Niederer, Steven; Wright, Matthew; O'Neill, Mark
2017-09-01
Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4-4-4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak-to-peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or <1 mV (22 ± 15%), and voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or <1 mV (13 ± 8%). Electrograms showing bipolar voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P < 0.001). There was a small but significant increase in conduction delay between unipole pairs at sites showing bipolar voltage attenuation (P = 0.026). Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate. © 2017 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.
Samanta, Rahul; Kumar, Saurabh; Chik, William; Qian, Pierre; Barry, Michael A; Al Raisi, Sara; Bhaskaran, Abhishek; Farraha, Melad; Nadri, Fazlur; Kizana, Eddy; Thiagalingam, Aravinda; Kovoor, Pramesh; Pouliopoulos, Jim
2017-10-01
Recent studies have demonstrated that intramyocardial adipose tissue (IMAT) may contribute to ventricular electrophysiological remodeling in patients with chronic myocardial infarction. Using an ovine model of myocardial infarction, we aimed to determine the influence of IMAT on scar tissue identification during endocardial contact mapping and optimal voltage-based mapping criteria for defining IMAT dense regions. In 7 sheep, left ventricular endocardial and transmural mapping was performed 84 weeks (15-111 weeks) post-myocardial infarction. Spearman rank correlation coefficient was used to assess the relationship between endocardial contact electrogram amplitude and histological composition of myocardium. Receiver operator characteristic curves were used to derive optimal electrogram thresholds for IMAT delineation during endocardial mapping and to describe the use of endocardial mapping for delineation of IMAT dense regions within scar. Endocardial electrogram amplitude correlated significantly with IMAT (unipolar r =-0.48±0.12, P <0.001; bipolar r =-0.45±0.22, P =0.04) but not collagen (unipolar r =-0.36±0.24, P =0.13; bipolar r =-0.43±0.31, P =0.16). IMAT dense regions of myocardium reliably identified using endocardial mapping with thresholds of <3.7 and <0.6 mV, respectively, for unipolar, bipolar, and combined modalities (single modality area under the curve=0.80, P <0.001; combined modality area under the curve=0.84, P <0.001). Unipolar mapping using optimal thresholding remained significantly reliable (area under the curve=0.76, P <0.001) during mapping of IMAT, confined to putative scar border zones (bipolar amplitude, 0.5-1.5 mV). These novel findings enhance our understanding of the confounding influence of IMAT on endocardial scar mapping. Combined bipolar and unipolar voltage mapping using optimal thresholds may be useful for delineating IMAT dense regions of myocardium, in postinfarct cardiomyopathy. © 2017 American Heart Association, Inc.
Kohl, T; Müller, A; Tchatcheva, K; Achenbach, S; Gembruch, U
2005-12-01
Because of insufficient imaging by maternal transabdominal fetal echocardiography (TAE) in a human fetus with aortic atresia, imperforate atrial septum and progressive cardiac failure, we assessed the feasibility of fetal transesophageal echocardiography (TEE) as a monitoring tool during fetal cardiac intervention at 24 + 6 weeks of gestation. Percutaneous fetoscopic intraesophageal deployment of the ultrasound catheter was achieved and did not result in any maternal or fetal complications. Fetal TEE permitted substantially clearer definition of fetal cardiac anatomy and intracardiac device manipulations than conventional maternal TAE. Despite the employment of various devices, no sufficiently large opening could be achieved within the atrial septum. Although the fetus tolerated the procedure remarkably well and satisfactory fetoplacental flow could be documented at the end of the procedure, the fetus died from progressive cardiac failure 3 days after the intervention. Fetoscopic TEE is feasible in the human fetus and permits substantially clearer definition of fetal cardiac anatomy and intracardiac manipulations than conventional maternal TAE. Based on the observation of spontaneous closure of multiple iatrogenic perforations of the atrial septum, specialized devices are required in order to improve the technical success rate of septoplasty methods and hence the survival odds of these high-risk patients.
NASA Technical Reports Server (NTRS)
Hohnloser, S. H.; Klingenheben, T.; Li, Y. G.; Zabel, M.; Peetermans, J.; Cohen, R. J.
1998-01-01
INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.
Efficient Removal of Retained Intracardiac Air Utilizing Buoyancy.
Orihashi, Kazumasa
2016-12-01
Retained intracardiac air has been an important issue in cardiac surgery. Although echo visualization has allowed detection of air and guided deairing procedures, adequate air removal is not always attained. Actually it has been attempted in each surgeon's manner without solid standard or evidence. Basically buoyancy is responsible for air retention as well as difficult deairing. This paper is aimed to present the author's current measures of deairing, which turn this property of air into efficient removal, as test bed for discussion on this long-standing but pending issue. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.
Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa
2016-03-01
A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.
Nikoozadeh, Amin; Wygant, Ira O.; Lin, Der-Song; Oralkan, Ömer; Ergun, A. Sanlı; Stephens, Douglas N.; Thomenius, Kai E.; Dentinger, Aaron M.; Wildes, Douglas; Akopyan, Gina; Shivkumar, Kalyanam; Mahajan, Aman; Sahn, David J.; Khuri-Yakub, Butrus T.
2009-01-01
Minimally invasive catheter-based electrophysiological (EP) interventions are becoming a standard procedure in diagnosis and treatment of cardiac arrhythmias. As a result of technological advances that enable small feature sizes and a high level of integration, nonfluoroscopic intracardiac echocardiography (ICE) imaging catheters are attracting increasing attention. ICE catheters improve EP procedural guidance while reducing the undesirable use of fluoroscopy, which is currently the common catheter guidance method. Phased-array ICE catheters have been in use for several years now, although only for side-looking imaging. We are developing a forward-looking ICE catheter for improved visualization. In this effort, we fabricate a 24-element, fine-pitch 1-D array of capacitive micromachined ultrasonic transducers (CMUT), with a total footprint of 1.73 mm × 1.27 mm. We also design a custom integrated circuit (IC) composed of 24 identical blocks of transmit/receive circuitry, measuring 2.1 mm × 2.1 mm. The transmit circuitry is capable of delivering 25-V unipolar pulses, and the receive circuitry includes a transimpedance preamplifier followed by an output buffer. The CMUT array and the custom IC are designed to be mounted at the tip of a 10-Fr catheter for high-frame-rate forward-looking intracardiac imaging. Through-wafer vias incorporated in the CMUT array provide access to individual array elements from the back side of the array. We successfully flip-chip bond a CMUT array to the custom IC with 100% yield. We coat the device with a layer of polydimethylsiloxane (PDMS) to electrically isolate the device for imaging in water and tissue. The pulse-echo in water from a total plane reflector has a center frequency of 9.2 MHz with a 96% fractional bandwidth. Finally, we demonstrate the imaging capability of the integrated device on commercial phantoms and on a beating ex vivo rabbit heart (Langendorff model) using a commercial ultrasound imaging system. PMID:19126489
REAL TIME MRI GUIDED RADIOFREQUENCY ATRIAL ABLATION AND VISUALIZATION OF LESION FORMATION AT 3-TESLA
Vergara, Gaston R.; Vijayakumar, Sathya; Kholmovski, Eugene G.; Blauer, Joshua J.E.; Guttman, Mike A.; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W.; Daccarett, Marcos; McGann, Christopher J.; MacLeod, Rob S.; Marrouche, Nassir F.
2011-01-01
Background MRI allows visualization of location and extent of RF ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT-MRI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. Objective To develop of a 3-Tesla RT-MRI based catheter ablation and lesion visualization system. Methods RF energy was delivered to six pigs under RT-MRI guidance. A novel MRI compatible mapping and ablation catheter was used. Under RT-MRI this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bi-polar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2w) HASTE sequence during ablation. Results Real-time visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement (LGE) MRI and macroscopic tissue examination. Conclusion MRI compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT-MRI guidance. It is also feasible to record electrograms during RT imaging. Real-time visualization of lesion as it forms during delivery of RF energy is possible and was demonstrated using T2w HASTE imaging. PMID:21034854
Faurie, Julia; Baudet, Mathilde; Assi, Kondo Claude; Auger, Dominique; Gilbert, Guillaume; Tournoux, Francois; Garcia, Damien
2017-02-01
Recent studies have suggested that intracardiac vortex flow imaging could be of clinical interest to early diagnose the diastolic heart function. Doppler vortography has been introduced as a simple color Doppler method to detect and quantify intraventricular vortices. This method is able to locate a vortex core based on the recognition of an antisymmetric pattern in the Doppler velocity field. Because the heart is a fast-moving organ, high frame rates are needed to decipher the whole blood vortex dynamics during diastole. In this paper, we adapted the vortography method to high-frame-rate echocardiography using circular waves. Time-resolved Doppler vortography was first validated in vitro in an ideal forced vortex. We observed a strong correlation between the core vorticity determined by high-frame-rate vortography and the ground-truth vorticity. Vortography was also tested in vivo in ten healthy volunteers using high-frame-rate duplex ultrasonography. The main vortex that forms during left ventricular filling was tracked during two-three successive cardiac cycles, and its core vorticity was determined at a sampling rate up to 80 duplex images per heartbeat. Three echocardiographic apical views were evaluated. Vortography-derived vorticities were compared with those returned by the 2-D vector flow mapping approach. Comparison with 4-D flow magnetic resonance imaging was also performed in four of the ten volunteers. Strong intermethod agreements were observed when determining the peak vorticity during early filling. It is concluded that high-frame-rate Doppler vortography can accurately investigate the diastolic vortex dynamics.
A preliminary study on atrial epicardial mapping signals based on Graph Theory.
Sun, Liqian; Yang, Cuiwei; Zhang, Lin; Chen, Ying; Wu, Zhong; Shao, Jun
2014-07-01
In order to get a better understanding of atrial fibrillation, we introduced a method based on Graph Theory to interpret the relations of different parts of the atria. Atrial electrograms under sinus rhythm and atrial fibrillation were collected from eight living mongrel dogs with cholinergic AF model. These epicardial signals were acquired from 95 unipolar electrodes attached to the surface of the atria and four pulmonary veins. Then, we analyzed the electrode correlations using Graph Theory. The topology, the connectivity and the parameters of graphs during different rhythms were studied. Our results showed that the connectivity of graphs varied from sinus rhythm to atrial fibrillation and there were parameter gradients in various parts of the atria. The results provide spatial insight into the interaction between different parts of the atria and the method may have its potential for studying atrial fibrillation. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Rocha, B. M.; Toledo, E. M.; Barra, L. P. S.; dos Santos, R. Weber
2015-01-01
Heart failure is a major and costly problem in public health, which, in certain cases, may lead to death. The failing heart undergo a series of electrical and structural changes that provide the underlying basis for disturbances like arrhythmias. Computer models of coupled electrical and mechanical activities of the heart can be used to advance our understanding of the complex feedback mechanisms involved. In this context, there is a lack of studies that consider heart failure remodeling using strongly coupled electromechanics. We present a strongly coupled electromechanical model to study the effects of deformation on a human left ventricle wedge considering normal and hypertrophic heart failure conditions. We demonstrate through a series of simulations that when a strongly coupled electromechanical model is used, deformation results in the thickening of the ventricular wall that in turn increases transmural dispersion of repolarization. These effects were analyzed in both normal and failing heart conditions. We also present transmural electrograms obtained from these simulations. Our results suggest that the waveform of electrograms, particularly the T-wave, is influenced by cardiac contraction on both normal and pathological conditions. PMID:26550570
A Clinical Feasibility Study of Atrial and Ventricular Electromechanical Wave Imaging
Provost, Jean; Gambhir, Alok; Vest, John; Garan, Hasan; Konofagou, Elisa E.
2014-01-01
Background Cardiac Resynchronization Therapy (CRT) and atrial ablation currently lack a noninvasive imaging modality for reliable treatment planning and monitoring. Electromechanical Wave Imaging (EWI) is an ultrasound-based method that has previously been shown to be capable of noninvasively and transmurally mapping the activation sequence of the heart in animal studies by estimating and imaging the electromechanical wave, i.e., the transient strains occurring in response to the electrical activation, at both very high temporal and spatial resolution. Objective Demonstrate the feasibility of noninvasive transthoracic EWI for mapping the activation sequence during different cardiac rhythms in humans. Methods EWI was performed in CRT patients with a left bundle-branch block (LBBB), during sinus rhythm, left-ventricular pacing, and right-ventricular pacing and in atrial flutter (AFL) patients before intervention and correlated with results from invasive intracardiac electrical mapping studies during intervention. Additionally, the feasibility of single-heartbeat EWI at 2000 frames/s, is demonstrated in humans for the first time in a subject with both AFL and right bundle-branch-block. Results The electromechanical activation maps demonstrated the capability of EWI to localize the pacing sites and characterize the LBBB activation sequence transmurally in CRT patients. In AFL patients, the propagation patterns obtained with EWI were in agreement with results obtained from invasive intracardiac mapping studies. Conclusion Our findings demonstrate the potential capability of EWI to aid in monitoring and follow-up of patients undergoing CRT pacing therapy and atrial ablation with preliminary validation in vivo. PMID:23454060
Papaioannou, Vasilios E; Verkerk, Arie O; Amin, Ahmed S; de Bakker, Jaques MT
2013-01-01
Heart rate variability (HRV) is an indirect estimator of autonomic modulation of heart rate and is considered a risk marker in critical illness, particularly in heart failure and severe sepsis. A reduced HRV has been found in critically ill patients and has been associated with neuro-autonomic uncoupling or decreased baroreflex sensitivity. However, results from human and animal experimental studies indicate that intracardiac mechanisms might also be responsible for interbeat fluctuations. These studies have demonstrated that different membrane channel proteins and especially the so-called ‘funny’ current (If), an hyperpolarization-activated, inward current that drives diastolic depolarization resulting in spontaneous activity in cardiac pacemaker cells, are altered during critical illness. Furthermore, membrane channels kinetics seem to have significant impact upon HRV, whose early decrease might reflect a cellular metabolic stress. In this review article we present research findings regarding intracardiac origin of HRV, at the cellular level and in both isolated sinoatrial node and whole ex vivo heart preparations. In addition, we will review results from various experimental studies that support the interrelation between If and HRV during endotoxemia. We suggest that reduced HRV during sepsis could also be associated with altered pacemaker cell membrane properties, due to ionic current remodeling. PMID:22920474
Noszczyk-Nowak, Agnieszka; Cepiel, Alicja; Janiszewski, Adrian; Pasławski, Robert; Gajek, Jacek; Pasławska, Urszula; Nicpoń, Józef
2016-01-01
Swine are a well-recognized animal model for human cardiovascular diseases. Despite the widespread use of porcine model in experimental electrophysiology, still no reference values for intracardiac electrical activity and conduction parameters determined during an invasive electrophysiology study (EPS) have been developed in this species thus far. The aim of the study was to develop a set of normal values for intracardiac electrical activity and conduction parameters determined during an invasive EPS of swine. The study included 36 healthy domestic swine (24-40 kg body weight). EPS was performed under a general anesthesia with midazolam, propofol and isoflurane. The reference values for intracardiac electrical activity and conduction parameters were calculated as arithmetic means ± 2 standard deviations. The reference values were determined for AH, HV and PA intervals, interatrial conduction time at its own and imposed rhythm, sinus node recovery time (SNRT), corrected sinus node recovery time (CSNRT), anterograde and retrograde Wenckebach points, atrial, atrioventricular node and ventricular refractory periods. No significant correlations were found between body weight and heart rate of the examined pigs and their electrophysiological parameters. The hereby presented reference values can be helpful in comparing the results of various studies, as well as in more accurately estimating the values of electrophysiological parameters that can be expected in a given experiment.
Risk of cerebrovascular events in patients with patent foramen ovale and intracardiac devices.
Poddar, Kanhaiya L; Nagarajan, Vijaiganesh; Krishnaswamy, Amar; Bajaj, Navkaranbir S; Kumari, Meera; Bdair, Hazem; Modi, Dhruv; Agarwal, Shikhar; Goel, Sachin S; Parashar, Akhil; Tuzcu, E Murat; Kapadia, Samir R
2014-11-01
This study investigated whether patients with patent foramen ovale (PFO) have an increased risk of stroke due to permanent pacemaker (PPM)/implantable cardioverter-defibrillator (ICD) implantation. Data are lacking on the risk of stroke in patients with PFO and implantable intracardiac devices, either a PPM or an ICD. We investigated whether patients with PFO have increased risk of stroke due to PPM/ICD implantation. Between 2001 and 2008, 2,921 consecutive patients with PFO (67.5 ± 16.4 years of age, 52.2% male) were identified from our echocardiography database. These patients were divided into a device group (patients had PPM/ICD implantation for any reason after receiving a diagnosis of PFO) and a no device group (patients did not have PPM or ICD implantation). Patients who had PFO closure during follow-up were excluded. Both groups were matched for baseline characteristics and medications. The incidence of ischemic stroke was assessed in each group after propensity score matching (case:control ratio of 1:1 yielding 231 pairs). All patients completed at least 4 years of follow-up until May 2012. There were 2,690 patients in the n device group (67.3 ± 16.4 years of age, 51.6% male) and 231 patients in the device group (75.4 ± 14.6 years of age, 59.3% male). Six patients (2.6%) in the no device group and 6 (2.6%) in the device group had a stroke during the follow-up period. No difference in the rate of stroke, transient ischemic stroke, or stroke/transient ischemic stroke was observed between the 2 groups. The risk of stroke in patients with PFO and an implantable intracardiac device is similar to those without an intracardiac device. In patients with PFO, without a history of stroke, device implantation might not be considered a risk factor for future stroke occurrence. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Prenatal diagnosis of prevalence of the right heart: associated anomalies and outcome predictors.
Peng, Ruan; Xie, Hong-Ning; Zhu, Yun-Xiao; Li, Li-Juan; Du, Liu; Zheng, Ju
2014-07-01
To analyze the characteristics, associations, and outcomes of prevalence of the right heart and to evaluate the use of sonography to predict the risk of a poor prognosis in fetuses with this condition. We conducted a retrospective cohort study of 182 fetuses with prevalence of the right heart. At the initial evaluation, the left ventricle (LV) and right ventricle (RV) sizes, left atrium and right atrium sizes, great artery diameters, appearance of the aortic arch and ductus arteriosus arch, and flow direction across the foramen ovale and aortic arch were documented. Malformations were documented in fetuses with intracardiac anomalies, who were divided into groups with and without coexisting extracardiac defects. The RV-LV diameter ratio and main pulmonary artery-to-aortic root diameter ratio were calculated and compared. The following variables were analyzed: coexisting intracardiac anomalies, associated extracardiac anomalies, diagnosis before 24 gestational weeks, fetal growth restriction, reversed flow across the foramen ovale, reversed flow in the aortic arch, and RV-LV ratio greater than 2.0. Relationships between these sonographic findings and the prognosis were evaluated by multivariable logistic regression. Of the 182 fetuses, 1 (0.5%) had intrauterine death, and 25 (13.7%) had neonatal death; 1 (0.5%) had selective reduction, and 106 (58.2%) underwent termination of pregnancy; 49 (26.9%) survived at this writing. The mean RV-LV ratio was 1.67. Multivariable logistic regression revealed that only 2 sonographic parameters, coexisting intracardiac anomalies (odds ratio, 17.75; 95% confidence interval, 4.18-75.26) and diagnosis before 24 weeks (odds ratio, 17.26; 95% confidence interval, 1.80-165.39) were significantly associated with a poor prognosis. The sonographic parameters of coexisting intracardiac anomalies and diagnosis before 24 gestational weeks are significant independent predictors of a poor prognosis in fetuses with prevalence of the right heart. Combinations of these risk factors may be useful in prenatal consultation. © 2014 by the American Institute of Ultrasound in Medicine.
Impact of Pulmonary Flow Study Pressure on Outcomes After One-Stage Unifocalization.
Trezzi, Matteo; Albanese, Sonia B; Albano, Antonio; Rinelli, Gabriele; D'Anna, Carolina; Polito, Angelo; Cetrano, Enrico; Carotti, Adriano
2017-12-01
The purpose of this study was to evaluate the accuracy of the pulmonary flow study in (1) predicting the feasibility of concomitant intracardiac repair after one-stage unifocalization; and in (2) predicting long-term survival and the onset of right ventricular dysfunction after surgery. Between October 1996 and July 2015, a flow study was obtained in 95 patients undergoing complete one-stage unifocalization for pulmonary atresia with ventricular septal defect and major aortopulmonary collaterals. The ability to achieve 100% flow (approximately 2.5 L · min -1 · m -2 ) into the pulmonary bed at a mean pressure of 30 mm Hg or less was utilized as an indicator for acceptability of ventricular septal defect closure. Overall survival was 78% ± 6% at 15 years. Sixty-four patients underwent successful one-stage intracardiac repair. The flow study accurately predicted suitability for VSD closure (area under the curve = 0.855). After one-stage ventricular septal defect closure, no difference in survival was observed after stratification according to flow study pressures (25 mm Hg or less versus greater than 25 mm Hg, log rank p = 0.20). At a median follow-up of 7 years, no association was found between flow study pressure and the onset of right ventricular dysfunction (p = 0.21). Overall, the inability to achieve final intracardiac repair was a strong predictor of death (hazard ratio 9.14, 95% confidence interval: 1.98 to 42.07, p < 0.0001). Suitability for ventricular septal defect closure is reliably defined by the flow study with a cutoff of 30 mm Hg. Flow study pressure values do not affect long-term outcomes. The ability to obtain intracardiac repair (in either one or more stages) is the strongest predictor of survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Prenatal diagnosis of atrial isomerism in the Korean population
Lee, Mi-Young; Shim, Jae-Yoon; Lee, Pil-Ryang; Lee, Byong Sop; Kim, Ellen Ai-Rhan; Kim, Young-Hwue; Park, Jeong-Jun; Yun, Tae-Jin; Kim, Ahm
2014-01-01
Objective To report our experiences in the prenatal diagnosis of atrial isomerism and postnatal outcomes. Methods A total of 80 fetuses prenatally diagnosed with atrial isomerism were retrospectively analyzed between 1999 and 2011 at a single institution. Results Of 43 fetuses with prenatally diagnosed right atrial isomerism (RAI), 40 cases were analyzed. The diagnostic accuracy was 93%. The main intracardiac anomalies in RAI were atrioventricular septal defect (AVSD), abnormal pulmonary venous connection, bilateral superior vena cava (BSVC), and pulmonary atresia. Among 28 live births, three infants were lost to follow up, and the overall survival rate was 60%. Of 37 fetuses with prenatally diagnosed left atrial isomerism (LAI), 35 were evaluated. The diagnostic accuracy was 97%. The main intracardiac anomalies in LAI were ventricular septal defect, BSVC, AVSD, double outlet right ventricle, and bradyarrhythmia. Among seven patients with bradyarrhythmia, only one showed a complete atrioventricular block. All fetuses had an interrupted inferior vena cava with azygous continuation. The overall survival rate was 90%. Conclusion Our study confirms the previous findings of fetal atrial isomerism. We also demonstrates a much lower prevalence of AVSD and complete heart block in LAI and a better survival rate in RAI. Although the postnatal outcomes for RAI were worse than those for LAI, successful postnatal surgery with active management improved the survival rate. PMID:24883290
Chen, Ying; Wu, Zhong; Yang, Cuiwei; Shao, Jun; Wong, Kelvin Kian Loong; Abbott, Derek
2012-09-01
Atrial fibrillation (AF) can result in life-threatening arrhythmia, and a clinically convenient means for detecting vulnerability remains elusive. We investigated atrial vulnerability by analyzing the sinus electrogram (EG) from AF animal models using a phase synchronization method. Using acetylcholine (ACh)-induced acute canine AF models (n= 4), a total of 128 electrical leads were attached to the surface of the anterior and posterior atria, and the pulmonary veins to form an electrocardiological mapping system. ACh was injected at varying concentrations with ladder-type adjustments. Sinus EGs and induced AF EGs that pertain to specific ACh concentrations were recorded.We hypothesize that the atrial vulnerability may be correlated with the Shannon entropy (SE) of the phase difference matrix that is extracted from the sinus EG. Our research suggests that the combination of SE with the synchronization method enables the sinus node EG to be analyzed and used to estimate atrial vulnerability.
Mechanistic Comparison of "Nearly Missed" Versus "On-Target" Rotor Ablation.
Yamazaki, Masatoshi; Avula, Uma Mahesh R; Berenfeld, Omer; Kalifa, Jérôme
2015-08-01
This study used advanced optical mapping techniques to examine atrial fibrillation (AF) dynamics before and after 2 distinct electrogram-based ablation strategies: complex fractionated atrial electrograms (CFAEs) and DFmax/rotor ablation. Among the electrogram analytical features proposed to unravel the atrial regions that perpetuate AF, CFAEs, highest dominant frequency sites (DFmax), and, more recently, phase analysis-enabled rotor mapping have received the largest attention. Still, the mechanisms by which these approaches modulate AF dynamics and lead to AF termination are unknown. In Langendorff-perfused sheep hearts, AF was maintained by the continuous perfusion of acetylcholine and high-resolution endocardial-epicardial optical videos were recorded from the left atrial free wall and the posterior left atrium. Then, DFmax/rotor regions (n = 7), or CFAE regions harboring the highest wavebreak density (HWD) (n = 5), were targeted with a 4F ablation catheter (5 to 15 W, 30 to 60 s/point). Thereafter, we examined the changes in AF dynamics and whether AF terminated. DFmax/rotor point ablation resulted in a significant decrease in DFmax values. In 2 animals AF terminated, whereas in the remaining 5 animals the post-ablation DFmax domain remained in the vicinity of its pre-ablation location. However, after HWD/CFAEs density ablation, DFmax values did not change, AF did not terminate, and post-ablation DFmax domains relocated from the left atrial free wall to the pulmonary vein-posterior left atrium region. In another group of hearts (n = 12), we observed that upon a progressive increase in acetylcholine concentration-mimicking the acute electrophysiological changes occurring after ablation-3-dimensional rotors drifted from one atrial region to another along large gradients of myocardial thickness. "On-target" DFmax/rotor ablation leads to the annihilation of the fibrillation-driving rotor. This translates into large decreases in AF frequency or AF termination. In contrast, "nearly missed" HWD/CFAEs ablation spares the fibrillation-driving rotor, and set the stage for rotor drift along large myocardial thickness gradients. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai
2016-10-01
The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.
Kyu, Kyu; Seow, Swee Chong; Wong, Raymond; Kojodjojo, Pipin
2016-03-17
An elderly Chinese man with moderately impaired left ventricular function, left bundle branch block and ST-elevation myocardial infarction complicated by ventricular septal rupture had class IV heart failure symptoms refractory to medical and surgical interventions. As a treatment of last resort, a cardiac resynchronisation therapy (CRT) pacemaker was implanted apprehensively, as preoperative concerns were raised whether CRT could exacerbate left-to-right shunting, hence negating the potential benefits of CRT. Introduction of CRT significantly improved the patient's haemodynamic status and symptoms, allowing for successful discharge home. To the best of our knowledge, this is the first report of a patient with severely symptomatic acute heart failure, widened QRS and active left-to-right intracardiac shunting, treated successfully with CRT. 2016 BMJ Publishing Group Ltd.
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
Aslan, Hamide; Dey, Ranadhir; Meneses, Claudio; Castrovinci, Philip; Jeronimo, Selma Maria Bezerra; Oliva, Gætano; Fischer, Laurent; Duncan, Robert C.; Nakhasi, Hira L.; Valenzuela, Jesus G.; Kamhawi, Shaden
2013-01-01
Background. Visceral leishmaniasis (VL) is transmitted by sand flies. Protection of needle-challenged vaccinated mice was abrogated in vector-initiated cutaneous leishmaniasis, highlighting the importance of developing natural transmission models for VL. Methods. We used Lutzomyia longipalpis to transmit Leishmania infantum or Leishmania donovani to hamsters. Vector-initiated infections were monitored and compared with intracardiac infections. Body weights were recorded weekly. Organ parasite loads and parasite pick-up by flies were assessed in sick hamsters. Results. Vector-transmitted L. infantum and L. donovani caused ≥5-fold increase in spleen weight compared with uninfected organs and had geometric mean parasite loads (GMPL) comparable to intracardiac inoculation of 107–108 parasites, although vector-initiated disease progression was slower and weight loss was greater. Only vector-initiated L. infantum infections caused cutaneous lesions at transmission and distal sites. Importantly, 45.6%, 50.0%, and 33.3% of sand flies feeding on ear, mouth, and testicular lesions, respectively, were parasite-positive. Successful transmission was associated with a high mean percent of metacyclics (66%–82%) rather than total GMPL (2.0 × 104–8.0 × 104) per midgut. Conclusions. This model provides an improved platform to study initial immune events at the bite site, parasite tropism, and pathogenesis and to test drugs and vaccines against naturally acquired VL. PMID:23288926
Salinet, João L; Masca, Nicholas; Stafford, Peter J; Ng, G André; Schlindwein, Fernando S
2016-03-08
Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based approach to generate the three-dimensional dominant frequency (3D DF) maps during electrophysiology (EP) procedures but literature is restricted on using alternative spectral estimation techniques that can have a better frequency resolution that FFT-based spectral estimation. Autoregressive (AR) model-based spectral estimation techniques, with emphasis on selection of appropriate sampling rate and AR model order, were implemented to generate high-density 3D DF maps of atrial electrograms (AEGs) in persistent atrial fibrillation (persAF). For each patient, 2048 simultaneous AEGs were recorded for 20.478 s-long segments in the left atrium (LA) and exported for analysis, together with their anatomical locations. After the DFs were identified using AR-based spectral estimation, they were colour coded to produce sequential 3D DF maps. These maps were systematically compared with maps found using the Fourier-based approach. 3D DF maps can be obtained using AR-based spectral estimation after AEGs downsampling (DS) and the resulting maps are very similar to those obtained using FFT-based spectral estimation (mean 90.23 %). There were no significant differences between AR techniques (p = 0.62). The processing time for AR-based approach was considerably shorter (from 5.44 to 5.05 s) when lower sampling frequencies and model order values were used. Higher levels of DS presented higher rates of DF agreement (sampling frequency of 37.5 Hz). We have demonstrated the feasibility of using AR spectral estimation methods for producing 3D DF maps and characterised their differences to the maps produced using the FFT technique, offering an alternative approach for 3D DF computation in human persAF studies.
Intracardiac electrophysiology study (EPS)
... rhythm Determine whether you are at risk for future heart events, especially sudden cardiac death See if ... patient with suspected arrhythmia. In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: ...
2014-01-01
Background It is important to understand the relationship between electrical and mechanical ventricular activation in CRT patients. By measuring local electrical activation at multiple locations within the coronary veins and myocardial contraction at the same locations in the left ventricle, we determined the relationship between electrical and mechanical activation at potential left ventricular pacing locations. Methods In this study, mechanical contraction times were computed using high temporal resolution cine cardiovascular magnetic resonance (CMR) data, while electrical activation times were derived from intra-procedural local electrograms. Results In our cohort, there was a strong correlation between electrical and mechanical delay times within each patient (R2 = 0.78 ± 0.23). Additionally, the latest electrically activated location corresponded with the latest mechanically contracting location in 91% of patients. Conclusions This study provides initial evidence that our method of obtaining non-invasive mechanical activation patterns accurately reflects the underlying electromechanical substrate of intraventricular dyssynchrony. PMID:24393383
Recurrent left ventricular myxoma presenting as cerebrovascular accidents in a teenage girl.
Vermeulen, Tom; Conraads, Viviane M; Vrints, Christiaan; Rodrigus, Inez E
2009-12-01
Myxoma cordis is the most frequent primary cardiac tumour in adults. Paediatric primary cardiac tumours are rare, the most common type being rhabdomyoma. Atrial and ventricular myxomas occur infrequently in the paediatric age group. Intracardiac myxomas are seen with an estimated incidence of 0.5 per million population per year. Approximately 70% of the affected patients are of female gender. Recurrences are rare (1.3%). Asymptomatic recurrences are observed in young patients who have a familial history of tumour or multifocal myxomas. Although rare, cardiac aetiology (atrial fibrillation, intracardiac thrombi, patent foramen ovale, myxoma, endocarditis) should be considered. In children presenting with central neurological symptoms, a cardiac aetiology has to be considered. We describe a rare case of an 18-year-old girl presenting with a recurrent left ventricular myxoma, accompanied by neurological deficits.
Lesizza, Pierluigi; Prosdocimo, Giulia; Martinelli, Valentina; Sinagra, Gianfranco; Zacchigna, Serena; Giacca, Mauro
2017-04-14
Recent evidence indicates that a few human microRNAs (miRNAs), in particular hsa-miR-199a-3p and hsa-miR-590-3p, stimulate proliferation of cardiomyocytes and, once expressed in the mouse heart using viral vectors, induce cardiac regeneration after myocardial infarction. Viral vectors, however, are not devoid of safety issues and, more notably, drive expression of the encoded miRNAs for indefinite periods of time, which might not be desirable in light of human therapeutic application. As an alternative to the use of viral vectors, we wanted to assess the efficacy of synthetic miRNA mimics in inducing myocardial repair after single intracardiac injection using synthetic lipid formulations. We comparatively analyzed the efficacy of different lipid formulations in delivering hsa-miR-199a-3p and hsa-miR-590-3p both in primary neonatal mouse cardiomyocytes and in vivo. We established a transfection protocol allowing persistence of these 2 mimics for at least 12 days after a single intracardiac injection, with minimal dispersion to other organs and long-term preservation of miRNA functional activity, as assessed by monitoring the expression of 2 mRNA targets. Administration of this synthetic formulation immediately after myocardial infarction in mice resulted in marked reduction of infarct size and persistent recovery of cardiac function. A single administration of synthetic miRNA-lipid formulations is sufficient to stimulate cardiac repair and restoration of cardiac function. © 2017 American Heart Association, Inc.
Kato, Hirohito; Dokai, Momoko; Katagiri, Ryuichi; Arima, Akihiro; Ooshima, Yojiro
2013-03-01
Japan Association for Laboratory Animal Medicine (JALAM) recommends humane handling of rat fetuses. However, it is a challenge to accept proposed euthanizing methods such as cervical dislocation, decapitation and/or intracardiac injection of potassium chloride, because these methods would damage fetal specimens for skeletal and visceral examinations in developmental toxicity studies. The present study aimed at seeking better methodologies for fetal euthanasia and anesthesia. We were unable to accomplish fetal euthanasia directly, but instead, we could euthanize fetuses under pain-controlled anesthesia. It is recommended that hypothermia by immersion in cold physiological saline is an appropriate method for anesthesia. Moreover, we recommend that the anesthetized fetuses should be euthanized immediately by removal of the vital organs or immersion in appropriate fixatives. © 2012 The Authors. Congenital Anomalies © 2012 Japanese Teratology Society.
NASA Astrophysics Data System (ADS)
Kaburaki, Kaori; Mozumi, Michiya; Hasegawa, Hideyuki
2018-07-01
Methods for the estimation of two-dimensional (2D) velocity and displacement of physiological tissues are necessary for quantitative diagnosis. In echocardiography with a phased array probe, the accuracy in the estimation of the lateral motion is lower than that of the axial motion. To improve the accuracy in the estimation of the lateral motion, in the present study, the coordinate system for ultrasonic beamforming was changed from the conventional polar coordinate to the Cartesian coordinate. In a basic experiment, the motion velocity of a phantom, which was moved at a constant speed, was estimated by the conventional and proposed methods. The proposed method reduced the bias error and standard deviation in the estimated motion velocities. In an in vivo measurement, intracardiac blood flow was analyzed by the proposed method.
Vandersickel, Nele; Bossu, Alexandre; De Neve, Jan; Dunnink, Albert; Meijborg, Veronique M F; van der Heyden, Marcel A G; Beekman, Jet D M; De Bakker, Jacques M T; Vos, Marc A; Panfilov, Alexander V
2017-12-26
This study investigated the arrhythmogenic mechanisms responsible for torsade de pointes (TdP) in the chronic atrioventricular block dog model, known for its high susceptibility for TdP. The mechanism of TdP arrhythmias has been under debate for many years. Focal activity as well as re-entry have both been mentioned in the initiation and the perpetuation of TdP. In 5 TdP-sensitive chronic atrioventricular block dogs, 56 needle electrodes were evenly distributed transmurally to record 240 unipolar local electrograms simultaneously. Nonterminating (NT) episodes were defibrillated after 10 s. Software was developed to automatically detect activation times and to create 3-dimensional visualizations of the arrhythmia. For each episode of ectopic activity (ranging from 2 beats to NT episodes), a novel methodology was created to construct directed graphs of the wave propagation and detect re-entry loops by using an iterative depth-first-search algorithm. Depending on the TdP definition (number of consecutive ectopic beats), we analyzed 29 to 54 TdP: 29 were longer than 5 beats. In the total group, 9 were NT and 45 were self-terminating. Initiation and termination were always based on focal activity. Re-entry becomes more important in the longer-lasting episodes (>14 beats), whereas in all NT TdP, re-entry was the last active mechanism. During re-entry, excitation fronts were constantly present in the heart, while during focal TdP, there was always a silent interval between 2 consecutive waves (142 ms) during which excitation fronts were absent. Interbeat intervals were significantly smaller for re-entry episodes-220 versus 310 ms in focal. Electrograms recorded in particular areas during NT TdP episodes had significantly smaller amplitude (0.38) than during focal episodes (0.59). TdP can be driven by focal activity as well as by re-entry depending on the duration of the episode. NT episodes are always maintained by re-entry, which can be identified in local unipolar electrograms by shorter interbeat intervals and smaller deflection amplitude. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lynn, W. D.; Escalona, O. J.; McEneaney, D. J.
2013-06-01
This study addresses an important question in the development of a ECG device that enables long term monitoring of cardiac rhythm. This device would utilise edge sensor technologies for dry, non-irritant skin contact suitable for distal limb application and would be supported by embedded ECG denoising processes. Contemporary ECG databases including those provided by MIT-BIH and Physionet are focused on interpretation of cardiac disease and rhythm tracking. The data is recorded using chest leads as in standard clinical practise. For the development of a peripherally located heart rhythm monitor, such data would be of limited use. To provide a useful database adequate for the development of the above mentioned cardiac monitoring device a unipolar body surface potential map from the left arm and wrist was gathered in 37 volunteer patients and characterized in this study. For this, the reference electrode was placed at the wrist. Bipolar far-field electrogram leads were derived and analysed. Factors such as skin variability, 50Hz noise interference, electrode contact noise, motion artifacts and electromyographic noise, presented a challenge. The objective was quantify the signal-to-noise ratio (SNR) at the far-field locations. Preliminary results reveal that an electrogram indicative of the QRS complex can be recorded on the distal portion of the left arm when denoised using signal averaging techniques.
Mianserin, maprotiline and intracardiac conduction
Edwards, J. Guy; Goldie, Ann
1983-01-01
1 High speed surface electrocardiograms were recorded in 35 patients during the baseline and after four weeks' treatment in a placebo-controlled trial of mianserin and maprotiline in primary depressive illness. 2 Measurements of the RR, PR and QT intervals, QRS width and T wave height were made blind to patient, drug and treatment interval and compared with plasma drug concentrations. The presence or absence of cardiac arrhythmias was recorded. 3 The only significant findings were an increased heart rate and PR interval and decreased QTc interval in the maprotiline group. Only one patient receiving maprotiline had a cardiac arrhythmia. There was no significant correlation between measurements of ECG parameters and plasma drug levels. 4 The results confirm the lack of cardiac effects of mianserin and show both anticholinergic activity and effects of an intracardiac conduction in the case of maprotiline. The mechanisms of these effects are discussed. PMID:6824556
[Results of the use of pumpan preparation in the treatment of severe forms of angina pectoris].
Parshina, S S; Golovacheva, T V; Afanas'eva, T N; Panchenko, O V; Baldina, A A; Starostina, N V; Lial'chenko, I F; Egorova, L P
2000-01-01
To assess validity of adjuvant use of pumpan, a homeopathic compound, in patients with unstable angina pectoris and angina of effort (functional class III-IV) receiving conventional treatment. A direct open controlled trial for 15 months performed initially in hospital, then outpatiently, covered 49 patients with severe angina. Examination of the patients included evaluation of clinical condition and the disease course, lipid metabolism, hemostasis, blood plasma electrolytes, aminotransferases, echo-CG, bicycle exercise, rheoencephalography, ultrasonic dopplerography of head and neck vessels. Pumpan produced a positive effect total nonspecific systemic resistance improved, number of hospitalizations reduced, intracardiac hemodynamics improved in some cases with severe angina. Homeopathic compound pumpan can be recommended in the treatment of severe angina to reinforce antianginal effect, improve the disease clinical course, to obtain a hypocoagulative and hypocholesterolemic effect, to normalize intracardiac hemodynamics, to raise myocardial performance and intracoronary reserve as well as nonspecific resistance of the body.
Pericardiectomy as a diagnostic and therapeutic procedure.
Konik, Ewa; Geske, Jeffrey; Edwards, William; Gersh, Bernard
2016-11-14
A 70-year-old man presented with recent onset, predominantly right-sided heart failure. Echocardiogram demonstrated features of hypertensive heart disease and was suggestive of, but non-diagnostic for, constrictive pericarditis (CP). CT demonstrated mild pericardial thickening. Right heart catheterisation showed elevation and equalisation of diastolic pressures in all cardiac chambers with early rapid filling, minimal ventricular interdependence, and no dissociation of intrathoracic and intracardiac pressures. While several features pointed towards CP, the minimal ventricular interdependence and no dissociation of intrathoracic and intracardiac pressures suggested other pathology. Diagnostic pericardiectomy was performed, after which the central venous pressure decreased from 22 to 12 mm Hg. Pathology revealed pericardial fibrosis. The patient experienced sustained resolution of his heart failure. A potential explanation for lack of CP criteria was the presence of hypertensive heart disease. CP needs to be considered when approaching patients with heart failure as diagnostic evaluation can be multifaceted and treatment curative. 2016 BMJ Publishing Group Ltd.
Brenner, L D; Caputo, G R; Mostbeck, G; Steiman, D; Dulce, M; Cheitlin, M D; O'Sullivan, M; Higgins, C B
1992-11-01
The purpose of this study was to evaluate the ability of velocity-encoded nuclear magnetic resonance (NMR) imaging to quantify left to right intracardiac shunts in patients with an atrial septal defect. Quantification of intracardiac shunts is clinically important in planning therapy. Velocity-encoded NMR imaging was used to quantify stroke flow in the aorta and in the main pulmonary artery in a group of patients who were known to have an increased pulmonary to systemic flow ratio (Qp/Qs). The velocity-encoded NMR flow data were used to calculate Qp/Qs, and these values were compared with measurements of Qp/Qs obtained with oximetric data derived from cardiac catheterization and from stroke volume measurements of the two ventricles by using volumetric data from biphasic spin echo and cine NMR images obtained at end-diastole and end-systole. Two independent observers measured Qp/Qs by using velocity-encoded NMR imaging in 11 patients and found Qp/Qs ranging from 1.4:1 to 3.9:1. These measurements correlated well with both oximetric data (r = 0.91, SEE = 0.35) and ventricular volumetric data (r = 0.94, SEE = 0.30). Interobserver reproducibility for Qp/Qs by velocity-encoded NMR imaging was good (r = 0.97, SEE = 0.20). Velocity-encoded NMR imaging is an accurate and reproducible method for measuring Qp/Qs in left to right shunts. Because it is completely noninvasive, it can be used to monitor shunt volume over time.
Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.
Schmidt, Ehud J; Tse, Zion T H; Reichlin, Tobias R; Michaud, Gregory F; Watkins, Ronald D; Butts-Pauly, Kim; Kwong, Raymond Y; Stevenson, William; Schweitzer, Jeffrey; Byrd, Israel; Dumoulin, Charles L
2014-03-01
Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner. An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI. Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C. An MRI-compatible VDT system is feasible. Copyright © 2013 Wiley Periodicals, Inc.
Nicogossian, A; Hoffler, G W; Johnson, R L; Gowen, R J
1976-04-01
A simple method to estimate cardiac size from single frontal plane chest roentgenograms has been described. Pre- and postflight chest X-rays from Apollo 17, and Skylab 2 and 3 have been analyzed for changes in the cardiac silhouette size. The data obtained from the computed cardiothoracic areal ratios compared well with the clinical cardiothoracic diametral ratios (r = .86). Though an overall postflight decrease in cardiac size is evident, the mean difference was not statistically significant (n = 8). The individual decreases in the cardiac silhouette size postflight are thought to be due to decrements in intracardiac chamber volumes rather than in myocardial muscle mass.
NASA Technical Reports Server (NTRS)
Nicogossian, A.; Hoffler, G. W.; Johnson, R. L.; Gowen, R. J.
1976-01-01
A simple method to estimate cardiac size from single frontal plane chest roentgenograms has been described. Pre- and postflight chest X-rays from Apollo 17, and Skylab 2 and 3 have been analyzed for changes in the cardiac silhouette size. The data obtained from the computed cardiothoracic areal ratios compared well with the clinical cardiothoracic diametral ratios (r = .86). Though an overall postflight decrease in cardiac size is evident, the mean difference was not statistically significant (n = 8). The individual decreases in the cardiac silhouette size postflight are thought to be due to decrements in intracardiac chamber volumes rather than in myocardial muscle mass.
Comparison of spectral estimators for characterizing fractionated atrial electrograms
2013-01-01
Background Complex fractionated atrial electrograms (CFAE) acquired during atrial fibrillation (AF) are commonly assessed using the discrete Fourier transform (DFT), but this can lead to inaccuracy. In this study, spectral estimators derived by averaging the autocorrelation function at lags were compared to the DFT. Method Bipolar CFAE of at least 16 s duration were obtained from pulmonary vein ostia and left atrial free wall sites (9 paroxysmal and 10 persistent AF patients). Power spectra were computed using the DFT and three other methods: 1. a novel spectral estimator based on signal averaging (NSE), 2. the NSE with harmonic removal (NSH), and 3. the autocorrelation function average at lags (AFA). Three spectral parameters were calculated: 1. the largest fundamental spectral peak, known as the dominant frequency (DF), 2. the DF amplitude (DA), and 3. the mean spectral profile (MP), which quantifies noise floor level. For each spectral estimator and parameter, the significance of the difference between paroxysmal and persistent AF was determined. Results For all estimators, mean DA and mean DF values were higher in persistent AF, while the mean MP value was higher in paroxysmal AF. The differences in means between paroxysmals and persistents were highly significant for 3/3 NSE and NSH measurements and for 2/3 DFT and AFA measurements (p<0.001). For all estimators, the standard deviation in DA and MP values were higher in persistent AF, while the standard deviation in DF value was higher in paroxysmal AF. Differences in standard deviations between paroxysmals and persistents were highly significant in 2/3 NSE and NSH measurements, in 1/3 AFA measurements, and in 0/3 DFT measurements. Conclusions Measurements made from all four spectral estimators were in agreement as to whether the means and standard deviations in three spectral parameters were greater in CFAEs acquired from paroxysmal or in persistent AF patients. Since the measurements were consistent, use of two or more of these estimators for power spectral analysis can be assistive to evaluate CFAE more objectively and accurately, which may lead to improved clinical outcome. Since the most significant differences overall were achieved using the NSE and NSH estimators, parameters measured from their spectra will likely be the most useful for detecting and discerning electrophysiologic differences in the AF substrate based upon frequency analysis of CFAE. PMID:23855345
Havranek, Stepan; Palecek, Tomas; Kovarnik, Tomas; Vitkova, Ivana; Psenicka, Miroslav; Linhart, Ales; Wichterle, Dan
2015-03-10
Left dominant arrhythmogenic cardiomyopathy (LDAC) is a rare condition characterised by progressive fibrofatty replacement of the myocardium of the left ventricle (LV) in combination with ventricular arrhythmias of LV origin. A thirty-five-year-old male was referred for evaluation of recurrent sustained monomorphic ventricular tachycardia (VT) of 200 bpm and right bundle branch block (RBBB) morphology. Cardiac magnetic resonance imaging showed late gadolinium enhancement distributed circumferentially in the epicardial layer of the LV free wall myocardium including the rightward portion of the interventricular septum (IVS). The clinical RBBB VT was reproduced during the EP study. Ablation at an LV septum site with absence of abnormal electrograms and a suboptimum pacemap rendered the VT of clinical morphology noninducible. Three other VTs, all of left bundle branch block (LBBB) pattern, were induced by programmed electrical stimulation. The regions corresponding to abnormal electrograms were identified and ablated at the mid-to-apical RV septum and the anteroseptal portion of the right ventricular outflow tract. No abnormalities were found at the RV free wall including the inferolateral peritricuspid annulus region. Histological examination confirmed the presence of abnormal fibrous and adipose tissue with myocyte reduction in endomyocardial samples taken from both the left and right aspects of the IVS. LDAC rarely manifests with sustained monomorphic ventricular tachycardia. In this case, several VTs of both RBBB and LBBB morphology were amenable to endocardial radiofrequency catheter ablation.
Rosman, Jonathan; Hanon, Sam; Shapiro, Michael; Evans, Steven J; Schweitzer, Paul
2006-04-01
The mechanisms underlying the initiation of sustained ventricular tachycardia (VT) have not been fully elucidated. The extent to which reentry, abnormal automaticity, and triggered activity play a role in VT differs depending on the etiology of left ventricular dysfunction. By analyzing electrograms from implantable cardioverter defibrillator (ICD), we sought to determine whether there were differences in VT initiation patterns between patients with ischemic and nonischemic cardiomyopathy. We analyzed ICD electrograms in patients with ejection fractions < 40% who had sustained VT over a 27-month period. The trigger for VT onset was classified as a ventricular premature beat (VPB), supraventricular tachycardia, or of "sudden onset." The baseline cycle length, VT cycle length, coupling interval, and prematurity ratio were recorded for each event. The prematurity ratio was calculated as the coupling interval of the VT initiator divided by the baseline cycle length. Sixty-three VT events in 14 patients met the inclusion criteria. A VPB initiated the VT in 58 episodes (92%), 1 episode (2%) was initiated by a supraventricular tachycardia, and 4 episodes (6%) were sudden onset. The prematurity ratio was significantly higher (P < 0.05) in patients with ischemic cardiomyopathy (0.751 +/- 0.068) as compared to patients with nonischemic cardiomyopathy (0.604 +/- 0.139). VPBs initiated most sustained VT episodes. A significantly higher prematurity ratio was observed in the ischemic heart disease group. This may represent different mechanisms of VT initiation in patients with ischemic versus nonischemic heart disease.
Leite, Luiz R; Santos, Simone N; Maia, Henrique; Henz, Benhur D; Giuseppin, Fábio; Oliverira, Anderson; Zanatta, André R; Peres, Ayrton K; Novakoski, Clarissa; Barreto, Jose R; Vassalo, Fabrício; d'Avila, Andre; Singh, Sheldon M
2011-04-01
Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patients undergoing atrial fibrillation ablation. Forty-five consecutive patients undergoing an atrial fibrillation ablation procedure followed by esophageal endoscopy were included in this prospective observational pilot study. LET monitoring was performed with a 7F deflectable ablation catheter that was positioned as close as possible to the site of left atrial ablation using the deflectable component of the catheter guided by visualization of its position on intracardiac echocardiography. Ablation in the posterior left atrial was limited to 25 W and terminated when the LET increased 2°C from baseline. Endoscopy was performed 1 to 2 days after the procedure. All patients had at least 1 LET elevation >2°C necessitating cessation of ablation. Deflection of the LET probe was needed to accurately measure LET in 5% of patients when ablating near the left pulmonary veins, whereas deflection of the LET probe was necessary in 88% of patients when ablating near the right pulmonary veins. The average maximum increase in LET was 2.5±1.5°C. No patients had esophageal thermal injury on follow-up endoscopy. A strategy of optimal LET probe placement using a deflectable LET probe and intracardiac echocardiography guidance, combined with cessation of radiofrequency ablation with a 2°C rise in LET, may reduce esophageal thermal injury during left atrial ablation procedures.
Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François
2017-01-01
Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Berti, Sergio; Paradossi, Umberto; Meucci, Francesco; Trianni, Giuseppe; Tzikas, Apostolos; Rezzaghi, Marco; Stolkova, Miroslava; Palmieri, Cataldo; Mori, Fabio; Santoro, Gennaro
2014-09-01
This dual-center study sought to demonstrate the utility and safety of intracardiac echocardiography (ICE) in providing adequate imaging guidance as an alternative to transesophageal echocardiography (TEE) during Amplatzer Cardiac Plug device implantation. Over 90% of intracardiac thrombi in atrial fibrillation originate from the left atrial appendage (LAA). Patients with contraindications to anticoagulation are potential candidates for LAA percutaneous occlusion. TEE is typically used to guide implantation. ICE-guided percutaneous LAA closure was performed in 121 patients to evaluate the following tasks typically achieved by TEE: assessment of the LAA dimension for device sizing; guidance of transseptal puncture; verification of the delivery sheath position; confirmation of location and stability of the device before and after release and continuous monitoring to detect procedural complications. In 51 consecutive patients, we compared the measurements obtained by ICE and fluoroscopy to choose the size of the device. The device was successfully implanted in 117 patients, yielding a technical success rate of 96.7%. Procedural success was achieved in 113 cases (93.4%). Four major adverse events (3 cardiac tamponades and 1 in-hospital transient ischemic attack) occurred. There was significant correlation in the measurements for device sizing assessed by angiography and ICE (r = 0.94, p < 0.0001). ICE imaging was able to perform the tasks typically provided by TEE during implantation of the Amplatzer Cardiac Plug device for LAA occlusion. Therefore, we provide evidence that the use of ICE offered accurate measurements of LAA dimension in order to select the correct device sizes. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Complications of intra-cardial placement of silastic central venous catheter in pediatric patients.
Soong, W J; Jeng, M J; Hwang, B
1996-01-01
A three-year prospective study was undertaken to determine the incidence and early complications from intra-cardiac placement of percutaneous central venous catheter (CVC). CVC was inserted by using "Catheter-through-needle" technique, and the insertion length was measured by body surface landmark. CVC course and tip location were routinely checked by roentgenography. Echocardiography was performed in case of arrhythmia. After analysis of 784 CVCs, 104 (13.3%) were proved to be intra-cardial, as located by either roentgenography or echocardiography. However, catheters passed via the upper trunk (14.5%) were significantly (p < 0.05) more intra-cardially located than those via the lower trunk (4.8%). Catheters which passed via the right upper trunk veins (basilic, cephalic, or external jugular veins) were also more intra-cardially located than those via their left veins counterparts, but the finding was not statistically significant (p > 0.05). The mean body weight (3.1 +/- 2.4 kg) in the intra-cardial placement group was significantly (p < 0.05) less than that in the non-intracardial placement group (7.9 +/- 4.5 kg). In intra-cardial placement patients, 32 cases (30.8%) had episode(s) of cardiac arrhythmia including 31 premature ventricular depolarization and 1 supra-ventricular tachycardia. All cases showed the presence of intra-ventricular catheter. All arrhythmias ceased abruptly after the catheters were pulled from the hearts. No other early complications were observed. the incidence of the intracardiac placement of CVC is high, especially in small infants or when the insertion via the upper trunk. Short term intra-cardiac catheter placement has a benign clinical course except that the intraventricular catheter may cause arrhythmia. However, this kind of arrhythmia can be resolved spontaneously by withdrawing the catheter.
Sorensen, Sherman G; Spruance, Spotswood L; Smout, Randall; Horn, Susan
2012-06-01
Percutaneous, mechanical closure of defects of the atrial septum fails to completely resolve shunting in up to 20% of cases. Little is known about the factors associated with device failure. We measured the left atrial opening (X), right atrial opening (Z), tunnel length (Y), septum secundum, device-septum primum separation, and tunnel compressibility of the patent foramen ovale (PFO) in 301 patients with cryptogenic neurological events, PFO anatomy, and severe Valsalva shunting (Spencer Grade 5-5+). All patients then underwent percutaneous closure with the GORE®HELEX Septal Occluder device and were evaluated at 3 months for residual shunt by transcranial Doppler (TCD). Severe residual Valsalva shunt (TCD Grade 5-5+) was found at 3 months in 21 of 301 (7%) patients. X, Y, and Z were associated with failure with a high degree of statistical significance, whereas the width of the septum secundum, device-septum primum separation, and tunnel compressibility were not. An unanticipated finding was that 14 of 35 (40%) patients sized with a large balloon failed compared with 9 of 280 (3%) sized with a small balloon (P < 0.0001). In the multivariate logistic regression model, X (P = < 0.0001) and balloon size (P < 0.0001) were both strong predictors of failure. In an intracardiac echocardiography-defined PFO population, characterized by severe baseline Valsalva shunt and a high incidence of persistent (rest) shunting, association of six intracardiac measurements to closure device failure by multivariate logistic regression showed that the width of the left atrial opening was a strong predictor of residual shunting. An unanticipated finding was that use of a large sizing balloon was also strongly associated with failure. ©2012, Wiley Periodicals, Inc.
Durães, André Rodrigues; de Souza Roriz, Pollianna; de Almeida Nunes, Bianca; Albuquerque, Felipe Pinho E; de Bulhões, Fábio Vieira; de Souza Fernandes, Andre Mauricio; Aras, Roque
2016-06-01
Dabigatran is a direct thrombin inhibitor shown to be an effective alternative to warfarin in patients with non-valvular atrial fibrillation (AF). We evaluated the use of dabigatran in patients with bioprosthetic mitral and/or aortic valve replacement and AF. We selected 34 and randomized 27 patients in a 1:1 ratio to receive dabigatran or warfarin. The primary endpoint was the presence of a new intracardiac thrombus at 90 days, by transesophageal echocardiogram (TEE). Secondary endpoints included the development of dense spontaneous echo contrast (SEC) and incidence of stroke (ischemic or hemorrhagic), myocardium infarction, valve thrombosis and peripheral embolic events. The trial was terminated prematurely because of low enrollment. There were 27 patients in total: 15 patients placed in the dabigatran group and 12 in the warfarin group. After 90 days, one patient (8.3 %) in the warfarin group and none in the dabigatran group had developed a new intracardiac thrombus. In the dabigatran group, two patients (13.3 %) developed dense SEC versus one patient (8.3 %) in the warfarin group. In the warfarin group, one patient (8.3 %) presented ischemic stroke, and none did in the dabigatran group. We observed no cases of hemorrhagic stroke, valve thrombosis, embolic events or myocardial infarction in either group throughout the study. However, one patient (6.7 %) in the dabigatran group had a fully recovered transient ischemic attack and one patient in the warfarin group died of heart failure. The use of dabigatran appears to be similar to warfarin in preventing the formation of intracardiac thrombus. Clinicaltrials.gov NCT01868243.
Joyce, William; Axelsson, Michael; Altimiras, Jordi; Wang, Tobias
2016-07-15
The ventricles of non-crocodilian reptiles are incompletely divided and provide an opportunity for mixing of oxygen-poor blood and oxygen-rich blood (intracardiac shunting). However, both cardiac morphology and in vivo shunting patterns exhibit considerable interspecific variation within reptiles. In the present study, we develop an in situ double-perfused heart approach to characterise the propensity and capacity for shunting in five reptile species: the turtle Trachemys scripta, the rock python Python sebae, the yellow anaconda Eunectes notaeus, the varanid lizard Varanus exanthematicus and the bearded dragon Pogona vitticeps To simulate changes in vascular bed resistance, pulmonary and systemic afterloads were independently manipulated and changes in blood flow distribution amongst the central outflow tracts were monitored. As previously demonstrated in Burmese pythons, rock pythons and varanid lizards exhibited pronounced intraventricular flow separation. As pulmonary or systemic afterload was raised, flow in the respective circulation decreased. However, flow in the other circulation, where afterload was constant, remained stable. This correlates with the convergent evolution of intraventricular pressure separation and the large intraventricular muscular ridge, which compartmentalises the ventricle, in these species. Conversely, in the three other species, the pulmonary and systemic flows were strongly mutually dependent, such that the decrease in pulmonary flow in response to elevated pulmonary afterload resulted in redistribution of perfusate to the systemic circuit (and vice versa). Thus, in these species, the muscular ridge appeared labile and blood could readily transverse the intraventricular cava. We conclude that relatively minor structural differences between non-crocodilian reptiles result in the fundamental changes in cardiac function. Further, our study emphasises that functionally similar intracardiac flow separation evolved independently in lizards (varanids) and snakes (pythons) from an ancestor endowed with the capacity for large intracardiac shunts. © 2016. Published by The Company of Biologists Ltd.
Muscarinic receptor-mediated excitation of rat intracardiac ganglion neurons.
Hirayama, Michiko; Ogata, Masanori; Kawamata, Tomoyuki; Ishibashi, Hitoshi
2015-08-01
Modulation of the membrane excitability of rat parasympathetic intracardiac ganglion neurons by muscarinic receptors was studied using an amphotericin B-perforated patch-clamp recording configuration. Activation of muscarinic receptors by oxotremorine-M (OxoM) depolarized the membrane, accompanied by repetitive action potentials. OxoM evoked inward currents under voltage-clamp conditions at a holding potential of -60 mV. Removal of extracellular Ca(2+) markedly increased the OxoM-induced current (IOxoM). The inward IOxoM in the absence of extracellular Ca(2+) was fully inhibited by removal of extracellular Na(+), indicating the involvement of non-selective cation channels. The IOxoM was inhibited by organic cation channel antagonists including SKF-96365 and ML-204. The IOxoM was antagonized by muscarinic receptor antagonists with the following potency: 4-DAMP > pirenzepine = darifenacin > methoctramine. Muscarinic toxin 7 (MT-7), a highly selective inhibitor for M1 receptor, produced partial inhibition of the IOxoM. In the presence of MT-7, concentration-inhibition curve of the M3-preferring antagonist darifenacin was shifted to the left. These results suggest the contribution of M1 and M3 receptors to the OxoM response. The IOxoM was inhibited by U-73122, a phospholipase C inhibitor. The membrane-permeable IP3 receptor blocker xestospongin C also inhibited the IOxoM. Furthermore, pretreatment with thapsigargin and BAPTA-AM inhibited the IOxoM, while KN-62, a blocker of Ca(2+)/calmodulin-dependent protein kinase II, had no effect. These results suggest that the activation mechanism involves a PLC pathway, release of Ca(2+) from intracellular Ca(2+) stores and calmodulin. The cation channels activated by muscarinic receptors may play an important role in neuronal membrane depolarization in rat intracardiac ganglion neurons. Copyright © 2015 Elsevier Ltd. All rights reserved.
A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography.
Lee, Warren; Griffin, Weston; Wildes, Douglas; Buckley, Donald; Topka, Terry; Chodakauskas, Thaddeus; Langer, Mark; Calisti, Serge; Bergstøl, Svein; Malacrida, Jean-Pierre; Lanteri, Frédéric; Maffre, Jennifer; McDaniel, Ben; Shivkumar, Kalyanam; Cummings, Jennifer; Callans, David; Silvestry, Frank; Packer, Douglas
2011-07-01
We developed prototype real-time 3-D intracardiac echocardiography catheters with integrated micromotors, allowing internal oscillation of a low-profile 64-element, 6.2-MHz phased-array transducer in the elevation direction. Components were designed to facilitate rotation of the array, including a low-torque flexible transducer interconnect and miniature fixtures for the transducer and micromotor. The catheter tip prototypes were integrated with two-way deflectable 10-Fr catheters and used in in vivo animal testing at multiple facilities. The 4-D ICE catheters were capable of imaging a 90° azimuth by up to 180° elevation field of view. Volume rates ranged from 1 vol/sec (180° elevation) to approximately 10 vol/sec (60° elevation). We successfully imaged electrophysiology catheters, atrial septal puncture procedures, and detailed cardiac anatomy. The elevation oscillation enabled 3-D visualization of devices and anatomy, providing new clinical information and perspective not possible with current 2-D imaging catheters.
Synergistic nonuniform shortening of atrial refractory period induced by autonomic stimulation.
Takei, M; Furukawa, Y; Narita, M; Ren, L M; Karasawa, Y; Murakami, M; Chiba, S
1991-12-01
We investigated the nonuniform effects of autonomic nerve stimulation of the effective refractory period (ERP) of the right atrium in the anesthetized dog. Stimulation of the discrete intracardiac sympathetic nerves to the sinoatrial (SA) nodal region uniformly shortened ERPs at three sites in the right atrium after administration of atropine. Right ansa subclavia (RS) stimulation similarly shortened ERPs in the absence of atropine. Stimulation of the discrete intracardiac parasympathetic nerves to the SA nodal region (SAP stimulation) shortened ERPs of the right atrium in a nonuniform manner. Simultaneous RS and SAP stimulation additively shortened ERPs at each site and decreased sinus rate much more than SAP stimulation alone. Shortening of ERP induced by SAP stimulation was greater than that induced by RS stimulation at similar absolute changes in heart rate. These results suggest that simultaneous activation of sympathetic and parasympathetic nerves nonuniformly shortens the ERP in the right atrium as the algebraic sum of the individual responses to each stimulation. However, parasympathetics exert the principal neural control over atrial ERP.
A flash from the past: a case on long term follow-up of a "corridor" operation.
Ricciardi, Danilo; Sarkozy, Andrea; Wauters, Kristel; Brugada, Pedro
2013-01-01
An electrophysiological study in a patient with a previous corridor operation was performed because of syncope. The atrial electrograms showed the persistence of the sinus rhythm in the right atrial corridor despite an organized atrial fibrillation in the left atrium. The first case described of a long term follow-up in a corridor operation, one of the first described surgical approach for the treatment of atrial fibrillation, that gave the beginning to the non-pharmacological approach of this arrhythmia. Copyright © 2013 Elsevier Inc. All rights reserved.
Undersensing of VF in a patient with optimal R wave sensing during sinus rhythm.
Dekker, Lukas R C; Schrama, Tim A M; Steinmetz, Frans H L; Tukkie, Raymond
2004-06-01
We describe a case of potentially fatal undersensing of VF by a third generation ICD with predetermined automatic gain control. In this patient, ventricular sensing was optimal, as R wave amplitudes during sinus rhythm were at least 16 mV. Cyclical, high amplitude signals during VF elevated the sensing floor to such an extent that complete undersensing of subsequent lower amplitude local electrograms occurred. This led to bradypacing and complete ICD therapy failure. Therefore, high R wave amplitudes during sinus rhythm do not warrant flawless sensing during VF.
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker electrode function tester. 870.3720... electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is... measuring the patient's pacing threshold and intracardiac R-wave potential. (b) Classification. Class II...
Nascimento, Clarissa R.; Andrade, Daniele; Carvalho-Pinto, Carla Eponina; Serra, Rafaela Rangel; Vellasco, Lucas; Brasil, Guilherme; Ramos-Junior, Erivan Schnaider; da Mota, Julia Barbalho; Almeida, Larissa Nogueira; Andrade, Marcus V.; Correia Soeiro, Maria de Nazaré; Juliano, Luiz; Alvarenga, Patrícia Hessab; Oliveira, Ana Carolina; Sicuro, Fernando Lencastre; de Carvalho, Antônio C. Campos; Svensjö, Erik; Scharfstein, Julio
2017-01-01
During the course of Chagas disease, infectious forms of Trypanosoma cruzi are occasionally liberated from parasitized heart cells. Studies performed with tissue culture trypomastigotes (TCTs, Dm28c strain) demonstrated that these parasites evoke neutrophil/CXCR2-dependent microvascular leakage by activating innate sentinel cells via toll-like receptor 2 (TLR2). Upon plasma extravasation, proteolytically derived kinins and C5a stimulate immunoprotective Th1 responses via cross-talk between bradykinin B2 receptors (B2Rs) and C5aR. Awareness that TCTs invade cardiovascular cells in vitro via interdependent activation of B2R and endothelin receptors [endothelin A receptor (ETAR)/endothelin B receptor (ETBR)] led us to hypothesize that T. cruzi might reciprocally benefit from the formation of infection-associated edema via activation of kallikrein–kinin system (KKS). Using intravital microscopy, here we first examined the functional interplay between mast cells (MCs) and the KKS by topically exposing the hamster cheek pouch (HCP) tissues to dextran sulfate (DXS), a potent “contact” activator of the KKS. Surprisingly, although DXS was inert for at least 30 min, a subtle MC-driven leakage resulted in factor XII (FXII)-dependent activation of the KKS, which then amplified inflammation via generation of bradykinin (BK). Guided by this mechanistic insight, we next exposed TCTs to “leaky” HCP—forged by low dose histamine application—and found that the proinflammatory phenotype of TCTs was boosted by BK generated via the MC/KKS pathway. Measurements of footpad edema in MC-deficient mice linked TCT-evoked inflammation to MC degranulation (upstream) and FXII-mediated generation of BK (downstream). We then inoculated TCTs intracardiacally in mice and found a striking decrease of parasite DNA (quantitative polymerase chain reaction; 3 d.p.i.) in the heart of MC-deficient mutant mice. Moreover, the intracardiac parasite load was significantly reduced in WT mice pretreated with (i) cromoglycate (MC stabilizer) (ii) infestin-4, a specific inhibitor of FXIIa (iii) HOE-140 (specific antagonist of B2R), and (iv) bosentan, a non-selective antagonist of ETAR/ETBR. Notably, histopathology of heart tissues from mice pretreated with these G protein-coupled receptors blockers revealed that myocarditis and heart fibrosis (30 d.p.i.) was markedly and redundantly attenuated. Collectively, our study suggests that inflammatory edema propagated via activation of the MC/KKS pathway fuels intracardiac parasitism by generating infection-stimulatory peptides (BK and endothelins) in the edematous heart tissues. PMID:28824610
A system and method for online high-resolution mapping of gastric slow-wave activity.
Bull, Simon H; O'Grady, Gregory; Du, Peng; Cheng, Leo K
2014-11-01
High-resolution (HR) mapping employs multielectrode arrays to achieve spatially detailed analyses of propagating bioelectrical events. A major current limitation is that spatial analyses must currently be performed "off-line" (after experiments), compromising timely recording feedback and restricting experimental interventions. These problems motivated development of a system and method for "online" HR mapping. HR gastric recordings were acquired and streamed to a novel software client. Algorithms were devised to filter data, identify slow-wave events, eliminate corrupt channels, and cluster activation events. A graphical user interface animated data and plotted electrograms and maps. Results were compared against off-line methods. The online system analyzed 256-channel serosal recordings with no unexpected system terminations with a mean delay 18 s. Activation time marking sensitivity was 0.92; positive predictive value was 0.93. Abnormal slow-wave patterns including conduction blocks, ectopic pacemaking, and colliding wave fronts were reliably identified. Compared to traditional analysis methods, online mapping had comparable results with equivalent coverage of 90% of electrodes, average RMS errors of less than 1 s, and CC of activation maps of 0.99. Accurate slow-wave mapping was achieved in near real-time, enabling monitoring of recording quality and experimental interventions targeted to dysrhythmic onset. This work also advances the translation of HR mapping toward real-time clinical application.
[Pressure sensors to prevent cardiac decompensation].
Klug, Didier
2017-11-01
Most cases of hospitalisation for heart failure are preceded by episodes of cardiac decompensation. Preventing these episodes would improve quality of life and reduce mortality and treatment costs. The monitoring of intracardiac pressures, using innovative sensors, coupled with telemedicine, offers interesting perspectives. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
Murray, D. M.
1971-01-01
NASA contributions to cardiovascular monitoring are described along with innovations in intracardiac blood pressure monitoring. A brief overview of the process of NASA technology transfer in patient monitoring is presented and a list of bioinstrumentation tech briefs and the number of requests for technical support is included.
The left atrial catheter: its uses and complications.
Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I
1992-11-01
The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.
Potential fields on the ventricular surface of the exposed dog heart during normal excitation.
Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S; Taccardi, B
1983-06-01
We studied the normal spread of excitation on the anterior and posterior ventricular surface of open-chest dogs by recording unipolar electrograms from an array of 1124 electrodes spaced 2 mm apart. The array had the shape of the ventricular surface of the heart. The electrograms were processed by a computer and displayed as epicardial equipotential maps at 1-msec intervals. Isochrone maps also were drawn. Several new features of epicardial potential fields were identified: (1) a high number of breakthrough points; (2) the topography, apparent widths, velocities of the wavefronts and the related potential drop; (3) the topography of positive potential peaks in relation to the wavefronts. Fifteen to 24 breakthrough points were located on the anterior, and 10 to 13 on the posterior ventricular surface. Some were in previously described locations and many others in new locations. Specifically, 3 to 5 breakthrough points appeared close to the atrioventricular groove on the anterior right ventricle and 2 to 4 on the posterior heart aspect; these basal breakthrough points appeared when a large portion of ventricular surface was still unexcited. Due to the presence of numerous breakthrough points on the anterior and posterior aspect of the heart which had not previously been described, the spread of excitation on the ventricular surface was "mosaic-like," with activation wavefronts spreading in all directions, rather than radially from the two breakthrough points, as traditionally described. The positive potential peaks which lay ahead of the expanding wavefronts moved along preferential directions which were probably related to the myocardial fiber direction.
Ariyarathna, Nilshan; Kumar, Saurabh; Thomas, Stuart P; Stevenson, William G; Michaud, Gregory F
2018-06-01
Adequate catheter-tissue contact facilitates efficient heat energy transfer to target tissue. Tissue contact is thus critical to achieving lesion transmurality and success of radiofrequency (RF) ablation procedures, a fact recognized more than 2 decades ago. The availability of real-time contact force (CF)-sensing catheters has reinvigorated the field of ablation biophysics and optimized lesion formation. The ability to measure and display CF came with the promise of dramatic improvement in safety and efficacy; however, CF quality was noted to have just as important an influence on lesion formation as absolute CF quantity. Multiple other factors have emerged as key elements influencing effective lesion formation, including catheter stability, lesion contiguity and continuity, lesion density, contact homogeneity across a line of ablation, spatiotemporal dynamics of contact governed by cardiac and respiratory motion, contact directionality, and anatomic wall thickness, in addition to traditional ablation indices of power and RF duration. There is greater appreciation of surrogate markers as a guide to lesion formation, such as impedance fall, loss of pace capture, and change in unipolar electrogram morphology. In contrast, other surrogates such as tactile feedback, catheter motion, and electrogram amplitude are notably poor predictors of actual contact and lesion formation. This review aims to contextualize the role of CF sensing in lesion formation with respect of the fundamental principles of biophysics of RF ablation and summarize the state-of-the-art evidence behind the role of CF in optimizing lesion formation. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Porter, Michael; Spear, William; Akar, Joseph G; Helms, Ray; Brysiewicz, Neil; Santucci, Peter; Wilber, David J
2008-06-01
Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 +/- 18 sites/patient were identified (20 +/- 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow-up was 1 year. One-year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long-term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.
Zaman, Junaid A B; Sauer, William H; Alhusseini, Mahmood I; Baykaner, Tina; Borne, Ryan T; Kowalewski, Christopher A B; Busch, Sonia; Zei, Paul C; Park, Shirley; Viswanathan, Mohan N; Wang, Paul J; Brachmann, Johannes; Krummen, David E; Miller, John M; Rappel, Wouter Jan; Narayan, Sanjiv M; Peters, Nicholas S
2018-01-01
The mechanisms by which persistent atrial fibrillation (AF) terminates via localized ablation are not well understood. To address the hypothesis that sites where localized ablation terminates persistent AF have characteristics identifiable with activation mapping during AF, we systematically examined activation patterns acquired only in cases of unequivocal termination by ablation. We recruited 57 patients with persistent AF undergoing ablation, in whom localized ablation terminated AF to sinus rhythm or organized tachycardia. For each site, we performed an offline analysis of unprocessed unipolar electrograms collected during AF from multipolar basket catheters using the maximum -dV/dt assignment to construct isochronal activation maps for multiple cycles. Additional computational modeling and phase analysis were used to study mechanisms of map variability. At all sites of AF termination, localized repetitive activation patterns were observed. Partial rotational circuits were observed in 26 of 57 (46%) cases, focal patterns in 19 of 57 (33%), and complete rotational activity in 12 of 57 (21%) cases. In computer simulations, incomplete segments of partial rotations coincided with areas of slow conduction characterized by complex, multicomponent electrograms, and variations in assigning activation times at such sites substantially altered mapped mechanisms. Local activation mapping at sites of termination of persistent AF showed repetitive patterns of rotational or focal activity. In computer simulations, complete rotational activation sequence was observed but was sensitive to assignment of activation timing particularly in segments of slow conduction. The observed phenomena of repetitive localized activation and the mechanism by which local ablation terminates putative AF drivers require further investigation. © 2018 American Heart Association, Inc.
Model study of imaging myocardial infarction by intracardiac electrical impedance tomography.
Li, Ying; Rao, Liyun; Ling, Yuesheng; He, Renjie; Khoury, Dirar S
2008-01-01
Electrical impedance tomography (EIT) detects tissue composition inside a medium by determining its resistive properties, and uses various electrode configurations to pass a small electric current and measure corresponding potential. We investigated the feasibility of reconstructing scarred tissue inside the heart wall by employing EIT on the basis of a catheter carrying a plurality of electrodes and placed inside the blood-filled heart cavity. We built a computer model of the biological medium, and reconstructed the resistivity distribution using the finite element method and Tikhonov regularization. The results established the successful implementation of the numeric methods and the possibility of localizing and quantifying scarred myocardium. Novel application of EIT from inside the heart cavity could be useful during catheterization and may complement other diagnostic modalities. Further research is necessary to assess the impact of several factors on the accuracy of the reconstruction and include number of electrodes, catheter location, and scar size.
Stephens, Douglas N.; Truong, Uyen T.; Nikoozadeh, Amin; Oralkan, Ömer; Seo, Chi Hyung; Cannata, Jonathan; Dentinger, Aaron; Thomenius, Kai; de la Rama, Alan; Nguyen, Tho; Lin, Feng; Khuri-Yakub, Pierre; Mahajan, Aman; Shivkumar, Kalyanam; O’Donnell, Matt; Sahn, David J.
2012-01-01
Objectives The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. Methods The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. Results The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. Conclusions Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures. PMID:22298868
Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.; He, Bin
2011-01-01
Background Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. Objective This study aims to rigorously assess the imaging performance of a three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE) induced ventricular tachycardia (VT) in the rabbit heart. Methods Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computer tomography images were obtained to construct geometry model. Results The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72±0.04, and a relative error of 0.30±0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from imaged site of initial activation to pacing site or site of arrhythmias determined from intra-cardiac mapping was ~5mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. Conclusion 3-DCEI can non-invasively delineate important features of focal or multi-focal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequence of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. PMID:21397046
Nakamura, Kohki; Naito, Shigeto; Kaseno, Kenichi; Nakatani, Yosuke; Sasaki, Takehito; Anjo, Naofumi; Yamashita, Eiji; Kumagai, Koji; Funabashi, Nobusada; Kobayashi, Yoshio; Oshima, Shigeru
2017-02-01
We aimed to optimize the acquisition of the left atrial (LA) and pulmonary vein (PV) ultrasound contours for more accurate integration of intracardiac echocardiography (ICE) and computed tomography (CT) using the CARTO ® 3 system during atrial fibrillation (AF) ablation. Eighty-five AF patients underwent integration of ICE and CT using (1) the LA roof and posterior wall contours acquired from the right atrium (RA), (2) all LA/PV contours from the RA (Whole-RA-integration), (3) the LA roof/posterior wall contours from the RA and right ventricular outflow tract (RVOT) (Posterior-RA/RV-integration), and (4) all LA/PV contours from the RA and RVOT (Whole-RA/RV-integration). The integration accuracy was compared using the (1) surface registration error, (2) distances between the three-dimensional CT and eight specific sites on the anterior, posterior, superior, and inferior aspects of the right and left circumferential PV isolation lines, and (3) registration score: a score of 0 or 1 was assigned for whether or not each specific site was visually aligned with the CT, and summed for each method (0 best, 8 worst). Posterior-RA/RV-integration revealed a significantly lower surface registration error (1.30±0.15mm) than Whole-RA- and Whole-RA/RV-integration (p<0.001). The mean distances of the eight specific sites and the registration score for Posterior-RA/RV-integration (median 1.26mm and 2, respectively) were significantly smaller than those for the other integration approaches (p<0.001). Image integration with the LA roof and posterior wall contours acquired from the RA and RVOT may provide greater accuracy for catheter navigation with three-dimensional CT during AF ablation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Karabinis, Andreas; Saranteas, Theodosios; Karakitsos, Dimitrios; Lichtenstein, Daniel; Poularas, John; Yang, Clifford; Stefanadis, Christodoulos
2008-01-01
Introduction We conducted an ultrasound study to investigate echocardiographic artifacts in mechanically ventilated patients with lung pathology. Methods A total of 205 mechanically ventilated patients who exhibited lung atelectasis and/or pleural effusion were included in this 36-month study. The patients underwent lung echography and transthoracic echocardiography, with a linear 5 to 10 MHz and with a 1.5 to 3.6 MHz wide-angle phased-array transducer, respectively. Patients were examined by two experienced observers who were blinded to each other's interpretation. Results A total of 124 patients (60,48%) were hospitalized because of multiple trauma; 60 patients (29,26%) because of respiratory insufficiency, and 21 (10,24%) because of recent postoperative surgery. The mean duration ( ± standard deviation) of hospitalization was 35 ± 27 days. An intracardiac artifact was documented in 17 out of 205 patients (8.29%) by echocardiography. It was visible only in the apical views, whereas subsequent transesophageal echocardiography revealed no abnormalities. The artifact consisted of a mobile component that exhibited, on M-mode, a pattern of respiratory variation similar to the lung 'sinusoid sign'. Lung echography revealed lung atelectasis and/or pleural effusion adjacent to the heart, and a similar M-mode pattern was observed. The artifact was recorded within the left cardiac chambers in 11 cases and within the right cardiac chambers in six. Conclusions Lung atelectasis and/or pleural effusion may create a mirror image, intracardiac artifact in mechanically ventilated patients. The latter was named the 'cardiac-lung mass' artifact to underline the important diagnostic role of both echocardiography and lung echography in these patients. Trial registration This trial is ISRCTN registered: ISRCTN 49216096. PMID:18826590
Robotic cardiac surgery: an anaesthetic challenge.
Wang, Gang; Gao, Changqing
2014-08-01
Robotic cardiac surgery with the da Vinci robotic surgical system offers the benefits of a minimally invasive procedure, including a smaller incision and scar, reduced risk of infection, less pain and trauma, less bleeding and blood transfusion requirements, shorter hospital stay and decreased recovery time. Robotic cardiac surgery includes extracardiac and intracardiac procedures. Extracardiac procedures are often performed on a beating heart. Intracardiac procedures require the aid of peripheral cardiopulmonary bypass via a minithoracotomy. Robotic cardiac surgery, however, poses challenges to the anaesthetist, as the obligatory one-lung ventilation (OLV) and CO2 insufflation may reduce cardiac output and increase pulmonary vascular resistance, potentially resulting in hypoxaemia and haemodynamic compromise. In addition, surgery requires appropriate positioning of specialised cannulae such as an endopulmonary vent, endocoronary sinus catheter, and endoaortic clamp catheter under the guidance of transoesophageal echocardiography. Therefore, cardiac anaesthetists should have a working knowledge of these systems, OLV and haemodynamic support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Diagnostic value of imaging in infective endocarditis: a systematic review.
Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu
2017-01-01
Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhou, Heling; Zhao, Dawen
2014-03-06
Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.
Ker, James
2012-07-12
During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Weber, Martin; Motin, Leonid; Gaul, Simon; Beker, Friederike; Fink, Rainer H A; Adams, David J
2004-01-01
The effects of intravenous (i.v.) anaesthetics on nicotinic acetylcholine receptor (nAChR)-induced transients in intracellular free Ca2+ concentration ([Ca2+]i) and membrane currents were investigated in neonatal rat intracardiac neurons. In fura-2-loaded neurons, nAChR activation evoked a transient increase in [Ca2+]I, which was inhibited reversibly and selectively by clinically relevant concentrations of thiopental. The half-maximal concentration for thiopental inhibition of nAChR-induced [Ca2+]i transients was 28 μM, close to the estimated clinical EC50 (clinically relevant (half-maximal) effective concentration) of thiopental. In fura-2-loaded neurons, voltage clamped at −60 mV to eliminate any contribution of voltage-gated Ca2+ channels, thiopental (25 μM) simultaneously inhibited nAChR-induced increases in [Ca2+]i and peak current amplitudes. Thiopental inhibited nAChR-induced peak current amplitudes in dialysed whole-cell recordings by ∼ 40% at −120, −80 and −40 mV holding potential, indicating that the inhibition is voltage independent. The barbiturate, pentobarbital and the dissociative anaesthetic, ketamine, used at clinical EC50 were also shown to inhibit nAChR-induced increases in [Ca2+]i by ∼40%. Thiopental (25 μM) did not inhibit caffeine-, muscarine- or ATP-evoked increases in [Ca2+]i, indicating that inhibition of Ca2+ release from internal stores via either ryanodine receptor or inositol-1,4,5-trisphosphate receptor channels is unlikely. Depolarization-activated Ca2+ channel currents were unaffected in the presence of thiopental (25 μM), pentobarbital (50 μM) and ketamine (10 μM). In conclusion, i.v. anaesthetics inhibit nAChR-induced currents and [Ca2+]i transients in intracardiac neurons by binding to nAChRs and thereby may contribute to changes in heart rate and cardiac output under clinical conditions. PMID:15644873
Floré, Vincent; Claus, Piet; Symons, Rolf; Smith, Godfrey L; Sipido, Karin R; Willems, Rik
2013-08-01
There is convincing experimental evidence that cellular action potential duration (APD) alternans is arrhythmogenic but its relationship with body surface microvolt T-wave alternans (MTWA) remains unclear. We investigated the relationship between MTWA and APD alternans induced by alternating cycle length (CL) pacing in a pig model. In 10 pigs, catheters in the right atrium (RA) and right (RV) and left ventricle (LV) allowed pacing and recording of monophasic action potentials (MAP). During RA pacing at stable 500-ms CL, LV was paced at alternating CL (505 ms and 495 ms). Changing the alternating LV (A-LV) pacing delay changes the size of the region with alternating ventricular activation. Spectral analysis of intracardiac MAP was correlated with body surface MTWA. In a similar setup (during alternating pacing in RV and LV), we investigated concordant versus discordant APD alternans. Pacing the LV with subtle alternating cycle lengths at short A-LV delay leads to broad QRS (97 ± 10 ms), body surface MTWA (mean Valt 4.2 ± 1.8 µV), and positive RR-interval alternans. At longer A-LV delay, not resulting in QRS widening (68 ± 5 ms), body surface RR alternans was absent but MTWA remained detectable and was even more pronounced (8.7 ± 5.1 µV, P < 0.01). During both concordant and discordant pacing MTWA was present. The precordial leads were better for detecting discordant APD alternans (8.0 ± 2.9 µV and 12.8 ± 4.52 µV, P = 0.02). MTWA is a potent technique to detect subtle and isolated intracardiac APD alternans that is artificially induced by alternating pacing. In the same model, discordant activation alternans can only be discriminated from concordant when using a quantifying approach of MTWA analysis. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.
Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.
Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan
2014-01-01
Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.
Steding-Ehrenborg, K; Arvidsson, P M; Töger, J; Rydberg, M; Heiberg, E; Carlsson, M; Arheden, H
2016-01-01
The kinetic energy (KE) of intracardiac blood may play an important role in cardiac function. The aims of the present study were to 1) quantify and investigate the determinants of KE, 2) compare the KE expenditure of intracardiac blood between athletes and control subjects, and 3) quantify the amount of KE inside and outside the diastolic vortex. Fourteen athletes and fourteen volunteers underwent cardiac MRI, including four-dimensional phase-contrast sequences. KE was quantified in four chambers, and energy expenditure was calculated by determining the mean KE/cardiac index. Left ventricular (LV) mass was an independent predictor of diastolic LVKE (R(2) = 0.66, P < 0.001), whereas right ventricular (RV) end-diastolic volume was important for diastolic RVKE (R(2) = 0.76, P < 0.001). The mean KE/cardiac index did not differ between groups (control subjects: 0.53 ± 0.14 mJ·l(-1)·min·m(2) and athletes: 0.56 ± 0.21 mJ·l(-1)·min·m(2), P = 0.98). Mean LV diastolic vortex KE made up 70 ± 1% and 73 ± 2% of total LV diastolic KE in athletes and control subjects (P = 0.18). In conclusion, the characteristics of the LV as a pressure pump and the RV as a volume pump are demonstrated as an association between LVKE and LV mass and between RVKE and end-diastolic volume. This also suggests different filling mechanisms where the LV is dependent on diastolic suction, whereas the RV fills with a basal movement of the atrioventricular plane over "stationary" blood. Both groups had similar energy expenditure for intracardiac blood flow, indicating similar pumping efficiency, likely explained by the lower heart rate that cancels the higher KE per heart beat in athletes. The majority of LVKE is found within the LV diastolic vortex, in contrast to earlier findings. Copyright © 2016 the American Physiological Society.
Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery.
Horiuchi, Tetsuya; Masamune, Ken; Iwase, Yuki; Ymashita, Hiromasa; Tsukihara, Hiroyuki; Motomura, Noboru; Ohta, Yuji; Dohi, Takeyoshi
2011-07-01
To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries. We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip. However, some areas could not be observed with simple flushing of the liquid because the flushed liquid mixed with blood. Further, a large amount of liquid had to be flushed, which posed a risk of cardiac damage caused by excess volume. Therefore, to safely capture high-resolution images of the interior of the heart, an endoscope with a coaxial round jet nozzle through which plasma is flushed has been developed. And to reduce the volume of flushed liquid, the synchronization system of heartbeat and the endoscope system with plasma flushing has been developed. We conducted an in vivo experiment to determine whether we could observe intracardiac tissues in swine without the use of a heart-lung machine. As a result, we successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. Moreover, we were able to save up to 30% of the flushed liquid by replacing the original system with a synchronization system. And we evaluated the performance of the endoscope with the coaxial round jet nozzle by conducting fluid analysis and an in vitro experiment. We successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. And by replacing an original system to a synchronization system, we were able to save up to 30% of the flushed liquid. As a follow-up study, we plan to create a surgical flexible device for valve disease that can grasp, staple, and repair cardiac valves by endoscopic visualization.
A System and Method for Online High-Resolution Mapping of Gastric Slow-Wave Activity
Bull, Simon H.; O’Grady, Gregory; Du, Peng
2015-01-01
High-resolution (HR) mapping employs multielectrode arrays to achieve spatially detailed analyses of propagating bioelectrical events. A major current limitation is that spatial analyses must currently be performed “off-line” (after experiments), compromising timely recording feedback and restricting experimental interventions. These problems motivated development of a system and method for “online” HR mapping. HR gastric recordings were acquired and streamed to a novel software client. Algorithms were devised to filter data, identify slow-wave events, eliminate corrupt channels, and cluster activation events. A graphical user interface animated data and plotted electrograms and maps. Results were compared against off-line methods. The online system analyzed 256-channel serosal recordings with no unexpected system terminations with a mean delay 18 s. Activation time marking sensitivity was 0.92; positive predictive value was 0.93. Abnormal slow-wave patterns including conduction blocks, ectopic pacemaking, and colliding wave fronts were reliably identified. Compared to traditional analysis methods, online mapping had comparable results with equivalent coverage of 90% of electrodes, average RMS errors of less than 1 s, and CC of activation maps of 0.99. Accurate slow-wave mapping was achieved in near real-time, enabling monitoring of recording quality and experimental interventions targeted to dysrhythmic onset. This work also advances the translation of HR mapping toward real-time clinical application. PMID:24860024
Ajijola, Olujimi A.; Yagishita, Daigo; Patel, Krishan J.; Vaseghi, Marmar; Zhou, Wei; Yamakawa, Kentaro; So, Eileen; Lux, Robert L.; Mahajan, Aman
2013-01-01
Myocardial infarction (MI) induces neural and electrical remodeling at scar border zones. The impact of focal MI on global functional neural remodeling is not well understood. Sympathetic stimulation was performed in swine with anteroapical infarcts (MI; n = 9) and control swine (n = 9). A 56-electrode sock was placed over both ventricles to record electrograms at baseline and during left, right, and bilateral stellate ganglion stimulation. Activation recovery intervals (ARIs) were measured from electrograms. Global and regional ARI shortening, dispersion of repolarization, and activation propagation were assessed before and during sympathetic stimulation. At baseline, mean ARI was shorter in MI hearts than control hearts (365 ± 8 vs. 436 ± 9 ms, P < 0.0001), dispersion of repolarization was greater in MI versus control hearts (734 ± 123 vs. 362 ± 32 ms2, P = 0.02), and the infarcted region in MI hearts showed longer ARIs than noninfarcted regions (406 ± 14 vs. 365 ± 8 ms, P = 0.027). In control animals, percent ARI shortening was greater on anterior than posterior walls during right stellate ganglion stimulation (P = 0.0001), whereas left stellate ganglion stimulation showed the reverse (P = 0.0003). In infarcted animals, this pattern was completely lost. In 50% of the animals studied, sympathetic stimulation, compared with baseline, significantly altered the direction of activation propagation emanating from the intramyocardial scar during pacing. In conclusion, focal distal anterior MI alters regional and global pattern of sympathetic innervation, resulting in shorter ARIs in infarcted hearts, greater repolarization dispersion, and altered activation propagation. These conditions may underlie the mechanisms by which arrhythmias are initiated when sympathetic tone is enhanced. PMID:23893167
Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F
2011-02-01
Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
A reliability analysis of cardiac repolarization time markers.
Scacchi, S; Franzone, P Colli; Pavarino, L F; Taccardi, B
2009-06-01
Only a limited number of studies have addressed the reliability of extracellular markers of cardiac repolarization time, such as the classical marker RT(eg) defined as the time of maximum upslope of the electrogram T wave. This work presents an extensive three-dimensional simulation study of cardiac repolarization time, extending the previous one-dimensional simulation study of a myocardial strand by Steinhaus [B.M. Steinhaus, Estimating cardiac transmembrane activation and recovery times from unipolar and bipolar extracellular electrograms: a simulation study, Circ. Res. 64 (3) (1989) 449]. The simulations are based on the bidomain - Luo-Rudy phase I system with rotational fiber anisotropy and homogeneous or heterogeneous transmural intrinsic membrane properties. The classical extracellular marker RT(eg) is compared with the gold standard of fastest repolarization time RT(tap), defined as the time of minimum derivative during the downstroke of the transmembrane action potential (TAP). Additionally, a new extracellular marker RT90(eg) is compared with the gold standard of late repolarization time RT90(tap), defined as the time when the TAP reaches 90% of its resting value. The results show a good global match between the extracellular and transmembrane repolarization markers, with small relative mean discrepancy (
Nakahara, Shiro; Yamaguchi, Takanori; Hori, Yuichi; Anjo, Naofumi; Hayashi, Akiko; Kobayashi, Sayuki; Komatsu, Takaaki; Sakai, Yoshihiko; Fukui, Akira; Tsuchiya, Takeshi; Taguchi, Isao
2016-05-01
Atrial low-voltage zones (LVZs) may be related to maintenance of atrial fibrillation (AF). The influence of left atrial (LA) contact areas (CoAs) on reentrant or rotor-like sources maintaining AF has not been investigated. Forty patients with persistent AF (PsAF) were analyzed. Three representative CoA regions in the LA (ascending aorta: anterior wall; descending aorta: left inferior pulmonary vein; and vertebrae: posterior wall) were visualized by enhanced CT. Using circular catheters, the LVZs (<0.5 mV) were assessed after restoration of SR, and local activation mapping and frequency domain analyses were performed after induction of AF. Circular activation during AF was visually defined as sites with ≥2 rotations by serial electrograms encompassing >80% of the mean AF cycle length. A pivot was defined as the core of the localized circular activation. Anterior (39/40 patients, 98%), left pulmonary vein antrum (27/40, 68%), and posterior (19/40, 48%) CoAs were identified, and 80% (68/85) of those sites were overlapped by or close (<3 mm) to LVZs. Thirty-six (90%) patients demonstrated circular activation (3.1±1.7 sites/patients) along with significantly higher organized dominant frequencies (6.3 ± 0.5 Hz, regularity-index: 0.26 [0.23-0.41]) within the LA, and the average electrogram amplitude of those pivots was 0.30 mV (0.18-0.52). Of those sites, 55% (66/120) were located at or close to CoA regions. Catheter ablation including of LVZs neighboring CoAs terminated AF in 9 (23%) patients. External anatomical structures contacting the LA may be related to unique conduction properties in diseased myocardium necessary for PsAF maintenance. © 2016 Wiley Periodicals, Inc.
Itoh, Taihei; Kimura, Masaomi; Sasaki, Shingo; Owada, Shingen; Horiuchi, Daisuke; Sasaki, Kenichi; Ishida, Yuji; Takahiko, Kinjo; Okumura, Ken
2014-04-01
Low conduction velocity (CV) in the area showing low electrogram amplitude (EA) is characteristic of reentry circuit of atypical atrial flutter (AFL). The quantitative relationship between CV and EA remains unclear. We characterized AFL reentry circuit in the right atrium (RA), focusing on the relationship between local CV and bipolar EA on the circuit. We investigated 26 RA AFL (10 with typical AFL; 10 atypical incisional AFL; 6 atypical nonincisional AFL) using CARTO system. By referring to isochronal and propagation maps delineated during AFL, points activated faster on the circuit were selected (median, 7 per circuit). At the 196 selected points obtained from all patients, local CV measured between the adjacent points and bipolar EA were analyzed. There was a highly significant correlation between local CV and natural logarithm of EA (lnEA) (R(2) = 0.809, P < 0.001). Among 26 AFL, linear regression analysis of mean CV, calculated by dividing circuit length (152.3 ± 41.7 mm) by tachycardia cycle length (TCL) (median 246 msec), and mean lnEA, calculated by dividing area under curve of lnEA during one tachycardia cycle by TCL, showed y = 0.695 + 0.191x (where: y = mean CV, x = lnEA; R(2) = 0.993, P < 0.001). Local CV estimated from EA with the use of this formula showed a highly significant linear correlation with that measured by the map (R(2) = 0.809, P < 0.001). The lnEA and estimated local CV show a highly positive linear correlation. CV is possibly estimated by EA measured by CARTO mapping. © 2013 Wiley Periodicals, Inc.
Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y
2016-05-21
Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. ClinicalTrials.gov number: NCT01014741. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Randomized ablation strategies for the treatment of persistent atrial fibrillation: RASTA study.
Dixit, Sanjay; Marchlinski, Francis E; Lin, David; Callans, David J; Bala, Rupa; Riley, Michael P; Garcia, Fermin C; Hutchinson, Mathew D; Ratcliffe, Sarah J; Cooper, Joshua M; Verdino, Ralph J; Patel, Vickas V; Zado, Erica S; Cash, Nancy R; Killian, Tony; Tomson, Todd T; Gerstenfeld, Edward P
2012-04-01
The single-procedure efficacy of pulmonary vein isolation (PVI) is less than optimal in patients with persistent atrial fibrillation (AF). Adjunctive techniques have been developed to enhance single-procedure efficacy in these patients. We conducted a study to compare 3 ablation strategies in patients with persistent AF. Subjects were randomized as follows: arm 1, PVI + ablation of non-PV triggers identified using a stimulation protocol (standard approach); arm 2, standard approach + empirical ablation at common non-PV AF trigger sites (mitral annulus, fossa ovalis, eustachian ridge, crista terminalis, and superior vena cava); or arm 3, standard approach + ablation of left atrial complex fractionated electrogram sites. Patients were seen at 6 weeks, 6 months, and 1 year; transtelephonic monitoring was performed at each visit. Antiarrhythmic drugs were discontinued at 3 to 6 months. The primary study end point was freedom from atrial arrhythmias off antiarrhythmic drugs at 1 year after a single-ablation procedure. A total of 156 patients (aged 59±9 years; 136 males; AF duration, 47±50 months) participated (arm 1, 55 patients; arm 2, 50 patients; arm 3, 51 patients). Procedural outcomes (procedure, fluoroscopy, and PVI times) were comparable between the 3 arms. More lesions were required to target non-PV trigger sites than a complex fractionated electrogram (33±9 versus 22±9; P<0.001). The primary end point was achieved in 71 patients and was worse in arm 3 (29%) compared with arm 1 (49%; P=0.04) and arm 2 (58%; P=0.004). These data suggest that additional substrate modification beyond PVI does not improve single-procedure efficacy in patients with persistent AF. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00379301.
Navara, Rachita; Leef, George; Shenasa, Fatemah; Kowalewski, Christopher; Rogers, Albert J; Meckler, Gabriela; Zaman, Junaid A B; Baykaner, Tina; Park, Shirley; Turakhia, Mintu P; Zei, Paul; Viswanathan, Mohan; Wang, Paul J; Narayan, Sanjiv M
2018-01-29
To investigate mechanisms by which atrial fibrillation (AF) may terminate during ablation near the pulmonary veins before the veins are isolated (PVI). It remains unstudied how AF may terminate during ablation before PVs are isolated, or how patients with PV reconnection can be arrhythmia-free. We studied patients in whom PV antral ablation terminated AF before PVI, using two independent mapping methods. We studied patients with AF referred for ablation, in whom biatrial contact basket electrograms were studied by both an activation/phase mapping method and by a second validated mapping method reported not to create false rotational activity. In 22 patients (age 60.1 ± 10.4, 36% persistent AF), ablation at sites near the PVs terminated AF (77% to sinus rhythm) prior to PVI. AF propagation revealed rotational (n = 20) and focal (n = 2) patterns at sites of termination by mapping method 1 and method 2. Both methods showed organized sites that were spatially concordant (P < 0.001) with similar stability (P < 0.001). Vagal slowing was not observed at sites of AF termination. PV antral regions where ablation terminated AF before PVI exhibited rotational and focal activation by two independent mapping methods. These data provide an alternative mechanism for the success of PVI, and may explain AF termination before PVI or lack of arrhythmias despite PV reconnection. Mapping such sites may enable targeted PV lesion sets and improved freedom from AF. © 2018 Wiley Periodicals, Inc.
Baspinar, Osman; Sahin, Derya A; Yildirim, Ali
2016-04-01
We present the case report of a war victim child with severe burn scars, orthopnoea, and dyspnoea due to diffuse pulmonary thromboembolism. During ICU stay, a central venous catheter's 45-mm wire embolised into the heart. The embolised wire was successfully removed via transhepatic access through the creation of an artificial simple snare.
Neonatal atrial flutter after insertion of an intracardiac umbilical venous catheter
de Almeida, Marcos Moura; Tavares, Wládia Gislaynne de Sousa; Furtado, Maria Mônica Alencar Araripe; Fontenele, Maria Marcia Farias Trajano
2016-01-01
Abstract Objective: To describe a case of neonatal atrial flutter after the insertion of an intracardiac umbilical venous catheter, reporting the clinical presentation and reviewing the literature on this subject. Case description: A late-preterm newborn, born at 35 weeks of gestational age to a diabetic mother and large for gestational age, with respiratory distress and rule-out sepsis, required an umbilical venous access. After the insertion of the umbilical venous catheter, the patient presented with tachycardia. Chest radiography showed that the catheter was placed in the position that corresponds to the left atrium, and traction was applied. The patient persisted with tachycardia, and an electrocardiogram showed atrial flutter. As the patient was hemodynamically unstable, electric cardioversion was successfully applied. Comments: The association between atrial arrhythmias and misplaced umbilical catheters has been described in the literature, but in this case, it is noteworthy that the patient was an infant born to a diabetic mother, which consists in another risk factor for heart arrhythmias. Isolated atrial flutter is a rare tachyarrhythmia in the neonatal period and its identification is essential to establish early treatment and prevent systemic complications and even death. PMID:26525686
3D and 4D echo--applications in EP laboratory procedures.
Kautzner, Josef; Peichl, Petr
2008-08-01
3D echocardiography allows imaging and analysis of cardiovascular structures as they move in time and space, thus creating possibility for creation of 4D datasets (3D + time). Intracardiac echocardiography (ICE) further broadens the spectrum of echocardiographic techniques by allowing detailed imaging of intracardiac anatomy with 3D reconstructions. The paper reviews the current status of development of 3D and 4D echocardiography in electrophysiology. In ablation area, 3D echocardiography can enhance the performance of catheter ablation for complex arrhythmias such as atrial fibrillation. Currently, several strategies to obtain 3D reconstructions from ICE are available. One involves combination with electroanatomical mapping system; others create reconstruction from standard phased-array or single-element ICE catheter using special rotational or pull-back devices. Secondly, 3D echocardiography may be used for precise assessment of cardiac dyssynchrony before cardiac resynchronization therapy. Its reliable detection is expected to minimize number of non-responders to this treatment and optimize left ventricular lead positioning to get maximum hemodynamic benefit. The main potential benefit of 3D and 4D echocardiography in electrophysiology lie in real-time guidance of complex ablation procedures and precise assessment of cardiac dyssynchrony.
Peters, Bjoern; Ewert, Peter; Berger, Felix
2009-01-01
Intravascular or intracardiac stenoses occur in many forms of congenital heart disease (CHD). Therefore, the implantation of stents has become an accepted interventional procedure for stenotic lesions in pediatric cardiology. Furthermore, stents are know to be used to exclude vessel aneurysm or to ensure patency of existing or newly created intracardiac communications. With the further refinement of the first generation of devices, a variety of “modern” stents with different design characteristics have evolved. Despite the tremendous technical improvement over the last 20 years, the “ideal stent” has not yet been developed. Therefore, the pediatric interventionalist has to decide which stent is suitable for each lesion. On this basis, currently available stents are discussed in regard to their advantages and disadvantages for common application in CHD. New concepts and designs developed to overcome some of the existing problems, like the failure of adaptation to somatic growth, are presented. Thus, in the future, biodegradable or growth stents might replace the currently used generation of stents. This might truly lead to widening indications for the use of stents in the treatment of CHD. PMID:20300265
Wavelet-sparsity based regularization over time in the inverse problem of electrocardiography.
Cluitmans, Matthijs J M; Karel, Joël M H; Bonizzi, Pietro; Volders, Paul G A; Westra, Ronald L; Peeters, Ralf L M
2013-01-01
Noninvasive, detailed assessment of electrical cardiac activity at the level of the heart surface has the potential to revolutionize diagnostics and therapy of cardiac pathologies. Due to the requirement of noninvasiveness, body-surface potentials are measured and have to be projected back to the heart surface, yielding an ill-posed inverse problem. Ill-posedness ensures that there are non-unique solutions to this problem, resulting in a problem of choice. In the current paper, it is proposed to restrict this choice by requiring that the time series of reconstructed heart-surface potentials is sparse in the wavelet domain. A local search technique is introduced that pursues a sparse solution, using an orthogonal wavelet transform. Epicardial potentials reconstructed from this method are compared to those from existing methods, and validated with actual intracardiac recordings. The new technique improves the reconstructions in terms of smoothness and recovers physiologically meaningful details. Additionally, reconstruction of activation timing seems to be improved when pursuing sparsity of the reconstructed signals in the wavelet domain.
NASA Astrophysics Data System (ADS)
Sun, Deyu; Rettmann, Maryam E.; Holmes, David R.; Linte, Cristian A.; Packer, Douglas; Robb, Richard A.
2014-03-01
In this work, we propose a method for intraoperative reconstruction of a left atrial surface model for the application of cardiac ablation therapy. In this approach, the intraoperative point cloud is acquired by a tracked, 2D freehand intra-cardiac echocardiography device, which is registered and merged with a preoperative, high resolution left atrial surface model built from computed tomography data. For the surface reconstruction, we introduce a novel method to estimate the normal vector of the point cloud from the preoperative left atrial model, which is required for the Poisson Equation Reconstruction algorithm. In the current work, the algorithm is evaluated using a preoperative surface model from patient computed tomography data and simulated intraoperative ultrasound data. Factors such as intraoperative deformation of the left atrium, proportion of the left atrial surface sampled by the ultrasound, sampling resolution, sampling noise, and registration error were considered through a series of simulation experiments.
Lipscomb, K
1980-01-01
Biplane cineradiography is a potentially powerful tool for precise measurement of intracardiac dimensions. The most systematic approach to these measurements is the creation of a three-dimensional coordinate system within the x-ray field. Using this system, interpoint distances, such as between radiopaque clips or coronary artery bifurcations, can be calculated by use of the Pythagoras theorem. Alternatively, calibration factors can be calculated in order to determine the absolute dimensions of a structure, such as a ventricle or coronary artery. However, cineradiography has two problems that have precluded widespread use of the system. These problems are pincushion distortion and variable image magnification. In this paper, methodology to quantitate and compensate for these variables is presented. The method uses radiopaque beads permanently mounted in the x-ray field. The position of the bead images on the x-ray film determine the compensation factors. Using this system, measurements are made with a standard deviation of approximately 1% of the true value.
Defibrillation of the Heart With Low Tension Currents in Experimental Conditions.
1960-05-04
the coronary vessels. It became clear with the accumulation of subsequent ob- servations that chemical preparations in themselves are not im...the recommended chemopharmaceutical means against difibrillation were directed towards a decrease of the excitability Of the hearti numerous...Intracardiac Conductivity. "Klin. Med." (Clinical Medicine), No 3, 1956. Litman, N., Surgical Treatment of Heart Diseases . Works of the 26th Congress of
Miquel, M E; Hill, D L G; Baker, E J; Qureshi, S A; Simon, R D B; Keevil, S F; Razavi, R S
2003-06-01
The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2-3 mm apart) were acquired during breath holding. Depending on image quality, T1- or T2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.
Danhier, Pierre; Magat, Julie; Levêque, Philippe; De Preter, Géraldine; Porporato, Paolo E; Bouzin, Caroline; Jordan, Bénédicte F; Demeur, Gladys; Haufroid, Vincent; Feron, Olivier; Sonveaux, Pierre; Gallez, Bernard
2015-03-01
Cell tracking could be useful to elucidate fundamental processes of cancer biology such as metastasis. The aim of this study was to visualize, using MRI, and to quantify, using electron paramagnetic resonance (EPR), the entrapment of murine breast cancer cells labeled with superparamagnetic iron oxide particles (SPIOs) in the mouse brain after intracardiac injection. For this purpose, luciferase-expressing murine 4 T1-luc breast cancer cells were labeled with fluorescent Molday ION Rhodamine B SPIOs. Following intracardiac injection, SPIO-labeled 4 T1-luc cells were imaged using multiple gradient-echo sequences. Ex vivo iron oxide quantification in the mouse brain was performed using EPR (9 GHz). The long-term fate of 4 T1-luc cells after injection was characterized using bioluminescence imaging (BLI), brain MRI and immunofluorescence. We observed hypointense spots due to SPIO-labeled cells in the mouse brain 4 h after injection on T2 *-weighted images. Histology studies showed that SPIO-labeled cancer cells were localized within blood vessels shortly after delivery. Ex vivo quantification of SPIOs showed that less than 1% of the injected cells were taken up by the mouse brain after injection. MRI experiments did not reveal the development of macrometastases in the mouse brain several days after injection, but immunofluorescence studies demonstrated that these cells found in the brain established micrometastases. Concerning the metastatic patterns of 4 T1-luc cells, an EPR biodistribution study demonstrated that SPIO-labeled 4 T1-luc cells were also entrapped in the lungs of mice after intracardiac injection. BLI performed 6 days after injection of 4 T1-luc cells showed that this cell line formed macrometastases in the lungs and in the bones. Conclusively, EPR and MRI were found to be complementary for cell tracking applications. MRI cell tracking at 11.7 T allowed sensitive detection of isolated SPIO-labeled cells in the mouse brain, whereas EPR allowed the assessment of the number of SPIO-labeled cells in organs shortly after injection. Copyright © 2015 John Wiley & Sons, Ltd.
Comparison of Echo and MRI in the Imaging Evaluation of Intracardiac Masses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gulati, G., E-mail: gulatigurpreet@rediffmail.com; Sharma, S.; Kothari, S.S.
We compared the efficacy of echocardiography (ECHO) and magnetic resonance imaging (MRI) for evaluating intracardiac masses. Over an 8-yr period, 28 patients, 21 males, 7 females, 16 days-60 years of age (mean 25 years) with a suspected intracardiac mass on ECHO (transthoracic in all; transesophageal in 9) underwent an MRI examination. Five patients had a contrast-enhanced MRI. ECHO and MRI were compared with respect to their technical adequacy, ability to detect and suggest the likely etiology of the mass, and provide additional information (masses not seen with the other technique, inflow or outflow obstruction, and intramural component of an intracavitarymore » mass). With MRI, the image morphology (including signal intensity changes on the various sequences) and extracardiac manifestations were also evaluated. The diagnosis was confirmed by histopathology in 18, surgical inspection in 4, by follow- up imaging on conservative management in 5, and by typical extracardiac manifestations of the disease in 1 patient.Fifteen (54%) patients had tumors (benign 12, malignant 3), 5 had a thrombus or hematoma, and 4 each had infective or vascular lesions. Thirty-four masses (13 in ventricle, 11 septal, 7 atrial, 2 on valve and 1 in pulmonary artery) were seen on MRI, 28 of which were detected by ECHO. Transthoracic ECHO (TTE) and MRI were technically optimal in 82% and 100% of cases, respectively. Nine patients needed an additional transesophageal ECHO (TEE). Overall, MRI showed a mass in all patients, whereas ECHO missed it in 2 cases. In cases with a mass on both modalities, MRI detected 4 additional masses not seen on ECHO. MRI suggested the etiology in 21 (75%) cases, while the same was possible with ECHO (TTE and TEE) in 8 (29%) cases. Intramural component, extension into the inflow or outflow, outflow tract obstruction, and associated pericardial or extracardiac masses were better depicted on MRI. We conclude that MRI is advantageous over a combination of TTE and TEE for the detection and complete morphological and functional evaluation (hemodynamic effects) of cardiac masses.« less
Ouweneel, Dagmar M; Sjauw, Krischan D; Wiegerinck, Esther M A; Hirsch, Alexander; Baan, Jan; de Mol, Bas A J M; Lagrand, Wim K; Planken, R Nils; Henriques, José P S
2016-10-01
The use of intracardiac assist devices is expanding, and correct position of these devices is required for optimal functioning. The aortic valve is an important landmark for positioning of those devices. It would be of great value if the device position could be easily monitored on plain supine chest radiograph in the ICU. We introduce a ratio-based tool for determination of the aortic valve location on plain supine chest radiograph images, which can be used to evaluate intracardiac device position. Retrospective observational study. Large academic medical center. Patients admitted to the ICU and supported by an intracardiac assist device. We developed a ratio to determine the aortic valve location on supine chest radiograph images. This ratio is used to assess the position of a cardiac assist device and is compared with echocardiographic findings. Supine anterior-posterior chest radiographs of patients with an aortic valve prosthesis (n = 473) were analyzed to determine the location of the aortic valve. We calculated several ratios with the potential to determine the position of the aortic valve. The aortic valve location ratio, defined as the distance between the carina and the aortic valve, divided by the thoracic width, was found to be the best performing ratio. The aortic valve location ratio determines the location of the aortic valve caudal to the carina, at a distance of 0.25 ± 0.05 times the thoracic width for male patients and 0.28 ± 0.05 times the thoracic width for female patients. The aortic valve location ratio was validated using CT images of patients with angina pectoris without known valvular disease (n = 95). There was a good correlation between cardiac device position (Impella) assessed with the aortic valve location ratio and with echocardiography (n = 53). The aortic valve location ratio enables accurate and reproducible localization of the aortic valve on supine chest radiograph. This tool is easily applicable and can be used for assessment of cardiac device position in patients on the ICU.
Jang, Sung-Won; Kim, Dong-Bin; Kwon, Bum-Jun; Cho, Eun-Joo; Shin, Woo-Seung; Kim, Ji-Hoon; Jin, Seung-Won; Oh, Yong-Seog; Lee, Man-Young; Kim, Jae-Hyung
2009-01-01
Posteroseptal accessory pathways are often associated with coronary sinus diverticula. These diverticula contain myocardial coats which serve as a bypass tract. We report a 54-year-old woman who underwent radiofrequency (RF) catheter ablation for Wolff-Parkinson-White (WPW) syndrome. The surface electrocardiography (ECG) demonstrated pre-excitation, indicating a posteroseptal accessory pathway. A catheter ablation via a transaortic approach failed to ablate the accessory pathway. Coronary sinus venography revealed the presence of a diverticulum near the ostium. An electrogram in the neck of the diverticulum showed the coronary sinus myocardial extension potential, which was successfully ablated by delivery of RF energy. PMID:19949625
Segmentation of left atrial intracardiac ultrasound images for image guided cardiac ablation therapy
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Stephens, T.; Holmes, D. R.; Linte, C.; Packer, D. L.; Robb, R. A.
2013-03-01
Intracardiac echocardiography (ICE), a technique in which structures of the heart are imaged using a catheter navigated inside the cardiac chambers, is an important imaging technique for guidance in cardiac ablation therapy. Automatic segmentation of these images is valuable for guidance and targeting of treatment sites. In this paper, we describe an approach to segment ICE images by generating an empirical model of blood pool and tissue intensities. Normal, Weibull, Gamma, and Generalized Extreme Value (GEV) distributions are fit to histograms of tissue and blood pool pixels from a series of ICE scans. A total of 40 images from 4 separate studies were evaluated. The model was trained and tested using two approaches. In the first approach, the model was trained on all images from 3 studies and subsequently tested on the 40 images from the 4th study. This procedure was repeated 4 times using a leave-one-out strategy. This is termed the between-subjects approach. In the second approach, the model was trained on 10 randomly selected images from a single study and tested on the remaining 30 images in that study. This is termed the within-subjects approach. For both approaches, the model was used to automatically segment ICE images into blood and tissue regions. Each pixel is classified using the Generalized Liklihood Ratio Test across neighborhood sizes ranging from 1 to 49. Automatic segmentation results were compared against manual segmentations for all images. In the between-subjects approach, the GEV distribution using a neighborhood size of 17 was found to be the most accurate with a misclassification rate of approximately 17%. In the within-subjects approach, the GEV distribution using a neighborhood size of 19 was found to be the most accurate with a misclassification rate of approximately 15%. As expected, the majority of misclassified pixels were located near the boundaries between tissue and blood pool regions for both methods.
Fowler, Vance G.; Rieg, Siegbert; Peyerl-Hoffmann, Gabriele; Birkholz, Hanna; Hellmich, Martin; Kern, Winfried V.; Seifert, Harald
2011-01-01
(see the editorial commentary and Soriano and Mensa, on pages 10–12.) Background. Infective endocarditis (IE) is a severe complication in patients with nosocomial Staphylococcus aureus bacteremia (SAB). We sought to develop and validate criteria to identify patients at low risk for the development of IE in whom transesophageal echocardiography (TEE) might be dispensable. Methods. Consecutive patients with nosocomial SAB from independent cohorts in Europe (Invasive S. aureus Infection Cohort [INSTINCT]) and North America (S. aureus Bacteremia Group [SABG]) were evaluated for the presence of clinical criteria predicting an increased risk for the development of IE (ie, prolonged bacteremia of >4 days' duration, presence of a permanent intracardiac device, hemodialysis dependency, spinal infection, and nonvertebral osteomyelitis). Patients were observed closely for clinical signs and symptoms of IE during hospitalization and a 3-month follow-up period. Results. IE was present in 13 (4.3%) of 304 patients in the INSTINCT cohort and in 40 (9.3%) of 432 patients in the SABG cohort. Within 14 days after the first positive blood culture result, echocardiography was performed in 39.8% and 57.4% of patients in the INSTINCT and SABG cohorts, respectively. In patients with IE, the most common clinical prediction criteria present were prolonged bacteremia (69.2% vs 90% for INSTINCT vs SABG, respectively) and presence of a permanent intracardiac device (53.8% vs 32.5%). In total, 13 of 13 patients in the INSTINCT cohort and 39 of 40 patients in the SABG cohort with documented IE fulfilled at least 1 criterion (sensitivity, 100% vs. 97.5%; negative predictive value, 100% vs 99.2%). Conclusions. A simple criteria set for patients with nosocomial SAB can identify patients at low risk of IE. Patients who meet these criteria may not routinely require TEE. PMID:21653295
Kim, Se-Chan; Heinze, Ingo; Schmiedel, Alexandra; Baumgarten, Georg; Knuefermann, Pascal; Hoeft, Andreas; Weber, Stefan
2015-01-01
Visualisation of a central venous catheter (CVC) with ultrasound is restricted to the internal jugular vein (IJV). CVC tip position is confirmed by chest radiography, intracardiac ECG or transoesophageal/transthoracic echocardiography (TEE/TTE). We explored the feasibility, safety and accuracy of a right supraclavicular view for visualisation of the lower superior vena cava (SVC) and the right pulmonary artery (RPA) as an ultrasound landmark for real-time ultrasound-guided CVC tip positioning via the right IJV. Ultrasound was then compared with chest radiography. An observational pilot study. Bonn, University Hospital, Germany. From July to October 2012. Fifty-one patients scheduled for elective surgery. Reasons for exclusion were emergency procedure, thrombosis or small IJV lumen and mechanical obstacle to guidewire advancement. In 48 patients, CVC insertion via the right IJV and progress of the guidewire into the lower SVC were continuously guided by an ultrasound transducer in the right supraclavicular fossa. CVC tip position in lower SVC and tip-to-carina distance were assessed with chest radiography as a reference method and additionally with TEE in cardiothoracic patients. Insertion depth was compared with intracardiac ECG and body-height formula. The guidewire tip was seen in the SVC of all patients. In four patients, the tip was not visible in proximity of the RPA. Chest radiography and TEE confirmed CVC tip position in the lower SVC (zone A). Bland-Altman analysis revealed an average of difference of 1.6 cm for ultrasound versus ECG (95% limit of agreement -2 to 5 cm) and an average of difference of 1 cm for ultrasound versus body-height formula (95% limit of agreement -2 to 4 cm). Ultrasound via a right supraclavicular view is a feasible, well tolerated and accurate approach and should be further explored. Chest radiography confirmed CVC position in the lower SVC.
Management of asymptomatic intracardiac missiles using echocardiography.
Robison, R J; Brown, J W; Caldwell, R; Stone, K S; King, H
1988-09-01
A child sustained a low-velocity airgun pellet injury to the left ventricle. No cardiovascular compromise was produced. The foreign body was localized by two-dimensional echocardiography to the left ventricular chamber near the mitral valve, and subsequently removed through a left atriotomy incision. In asymptomatic patients, missiles clearly embedded within a chamber wall may be observed; all others should be removed. Two-dimensional echocardiography is recommended for localization.
Post-Mortem Magnetic Resonance Imaging Appearances of Feticide in Perinatal Deaths.
Shelmerdine, Susan C; Hickson, Melissa; Sebire, Neil J; Arthurs, Owen J
2018-06-06
The aim of this study was to characterise the imaging features seen in fetuses having undergone feticide by intracardiac potassium chloride injection compared to those of non-terminated fetuses at post-mortem magnetic resonance imaging (PMMRI). A case-control study was performed comparing PMMRI findings between two groups of patients - those having undergone feticide were matched to a control group of miscarried/stillborn fetuses. The groups were matched according to gestational age, weight, and time since death. Two independent readers reviewed the PMMRI for thoracic, abdominal, and musculoskeletal imaging features. The Fishers exact test was conducted for differences between the patient groups. Twenty-six cases of feticide (mean gestation 25 weeks [20-36]) and 75 non-terminated fetuses (mean gestation 26.7 weeks [19-36]) were compared. There was a higher proportion of feticide cases demonstrating pneumothorax (23.1 vs. 1.3%, p = 0.001), haemothorax (42.3 vs. 4%, p = 0.001), pneumopericardium (30.8 vs. 5.3%, p = 0.002), and haemopericardium (34.6 vs. 0%, p = 0.0001). Intracardiac gas and intra-abdominal findings were higher in the feticide group, but the differences were not statistically significant. Characteristic PMMRI features of feticide can help improve reporter confidence in differentiating iatrogenic from physiological/pathological processes. © 2018 S. Karger AG, Basel.
Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.
Basman, Craig; Parmar, Yuvrajsinh J; Kronzon, Itzhak
2017-09-06
With an increasing number of interventional procedures performed for structural heart disease and cardiac arrhythmias each year, echocardiographic guidance is necessary for safe and efficient results. The purpose of this review article is to overview the principles of intracardiac echocardiography (ICE) and describes the peri-interventional role of ICE in a variety of structural heart disease and electrophysiological interventions. Both transthoracic (TTE) and transesophageal echocardiography have limitations. ICE provides the advantage of imaging from within the heart, providing shorter image distances and higher resolution. ICE may be performed without sedation and avoids esophageal intubation as with transesophageal echocardiography (TEE). Limitations of ICE include the need for additional venous access with possibility of vascular complications, potentially higher costs, and a learning curve for new operators. Data supports the use of ICE in guiding device closure of interatrial shunts, transseptal puncture, and electrophysiologic procedures. This paper reviews the more recent reports that ICE may be used for primary guidance or as a supplement to TEE in patients undergoing left atrial appendage (LAA) closure, interatrial shunt closure, transaortic valve implantation (TAVI), percutaneous mitral valve repair (PMVR), paravalvular leak (PVL) closure, aortic interventions, transcatheter pulmonary valve replacement (tPVR), ventricular septal defect (VSD), and patent ductus arteriosus (PDA) closure. ICE imaging technology will continue to expand and help improve structural heart and electrophysiology interventions.
Statistical Segmentation of Surgical Instruments in 3D Ultrasound Images
Linguraru, Marius George; Vasilyev, Nikolay V.; Del Nido, Pedro J.; Howe, Robert D.
2008-01-01
The recent development of real-time 3D ultrasound enables intracardiac beating heart procedures, but the distorted appearance of surgical instruments is a major challenge to surgeons. In addition, tissue and instruments have similar gray levels in US images and the interface between instruments and tissue is poorly defined. We present an algorithm that automatically estimates instrument location in intracardiac procedures. Expert-segmented images are used to initialize the statistical distributions of blood, tissue and instruments. Voxels are labeled through an iterative expectation-maximization algorithm using information from the neighboring voxels through a smoothing kernel. Once the three classes of voxels are separated, additional neighboring information is combined with the known shape characteristics of instruments in order to correct for misclassifications. We analyze the major axis of segmented data through their principal components and refine the results by a watershed transform, which corrects the results at the contact between instrument and tissue. We present results on 3D in-vitro data from a tank trial, and 3D in-vivo data from cardiac interventions on porcine beating hearts, using instruments of four types of materials. The comparison of algorithm results to expert-annotated images shows the correct segmentation and position of the instrument shaft. PMID:17521802
Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin
2011-01-01
Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.
Electrical storms and their prognostic implications.
Awan, Zahid Aslam; ul Hassan, Mahmood; Bangash, Kamran; Shah, Bakhtawar; Noor, Lubna
2009-01-01
Prevention of sudden cardiac death has always been a challenge for electrophysiologists and to date, automatic implantable cardiovertor defibrillator (AICD) is found to be the only remedy. This device delivers an intracardiac shock whenever it senses a fatal ventricular arrhythmia in order to achieve sinus rhythm. If the delivery of these intracardiac shocks becomes frequent, the situation is declared as an electrical storm. This article deals with the frequency, precipitating factors and prevention of electrical storms. One hundred and ten episodes of electrical storms (a total of 668 shocks) were retrospectively analysed in 25 recipients of automatic implantable cardioverter defibrillators. ECG, echocardiography, serum electrolytes, urea and creatinine were done for all the patients, and they were hospitalized for a minimum of 24 hours. During the 3 year study period, all the 25 patients with an implantable cardiovertor defibrillator, on an average, received one shock per two years. However, 12 out of these 25 patients (50%) had more than two shocks within 24 hours. Most of these patients with electrical storms were having active ischemia, electrolytes imbalances or renal failure. Electrical storms are common in patients with coronary artery disease with impaired left ventricular functions. Ischemia, electrolytes imbalances and renal failure predispose to the electrical storms. Electrical Storms are predictors of poor prognosis.
Tazzioli, Giovanni; Gargaglia, Eleonora; Vecchioni, Ilaria; Papi, Simona; Di Blasio, Petronilla; Rossi, Rosario
2015-01-01
Central venous catheters are often required in oncologic patients for long-term safe administration of chemotherapeutic agents, antibiotics, and parenteral nutrition. Rupture of these devices and intracardiac migration is a rare complication. We report one spontaneous rupture and embolization of a totally implantable vascular access device (TIVAD) in an asymptomatic patient. A 50-year-old woman received a TIVAD silicone catheter 8 FR for adjuvant chemotherapy. After 3 years of port time in situ, during a follow-up control, a catheter malfunction was found and radiologic investigations showed a rupture and migration of the catheter to the right ventricle. The attempt to remove the fragment under fluoroscopic control using the femoral route was unsuccessful. We did not try a surgical approach because of the complete absence of symptomatology and hemodynamic impairment. The catheter rupture and intracardiac embolization is a rare complication associated with totally implantable or tunneled central venous catheters. When such an event happens, the patient should be managed by expert hemodynamists or interventional radiologists making an effort to remove the fragment without surgical measures. When the intravascular percutaneous route fails, the possibility to leave the fragmented catheter in heart chambers should be evaluated, being surgery questionable in asymptomatic patients.
Mirza, Fadi G; Ghulmiyyah, Labib; Tamim, Hani; Bou Hamdan, Farah; Breidy, Juliana; Geagea, Sandra; Usta, Ihab; Adra, Abdallah; Nassar, Anwar H
2016-01-01
The association between echogenic intracardiac focus (EIF) and trisomy 21 is well established, with a recognized ethnic variation. Our study aimed to determine the prevalence of EIF in a Middle Eastern population and to examine its association with trisomy 21 and other adverse pregnancy outcomes. Retrospective case-control study of second-trimester obstetric sonograms (16-28 weeks) performed at a tertiary care center over a 5-year period. Cases with EIF were retrieved, and a matched control group with no EIF was identified. The incidence of trisomy 21 and other adverse pregnancy outcomes was compared. A total of 9270 obstetric sonograms were examined, with an EIF prevalence of 2.5% (95% CI: 2.2-2.8%). Of patients with available outcome data, EIF was not associated with trisomy 21 (0/163 versus 1/163; p value = 1.00). Additionally, EIF was not associated with trisomy 18, trisomy 13, small for gestational age, preterm birth, fetal demise, cesarean delivery, operative vaginal delivery, or admission to the neonatal intensive care unit. In a contemporary Middle Eastern population, EIF is a rare occurrence. As an isolated finding, it is not associated with aneuploidy or other adverse pregnancy outcomes. EIF appears to be incidental with no impact on clinical practice.
Filogonio, Renato; Costa Leite, Cléo Alcantara; Wang, Tobias
2017-06-01
Our meta-analysis (Filogonio et al., 2017) on central vascular blood flows in a snake (Crotalus durissus) and a turtle (Trachemys scripta) was motivated by Hillman et al.'s (2014) analysis on amphibians to investigate whether cardiac shunt patterns depend on cardiac output and vascular distensibilities. In contrast to Hillman et al. (2014), we did not uncover a general trend that supports the notion that cardiac shunts in reptiles are dictated by vascular distensibilities. In addition to our response to the criticism raised by Hillman et al. (2017), we suggest that future experiments should consider (i) both compliance and distensibility of the major arteries; (ii) differences in volume of the systemic and pulmonary circuits to account for the accommodation of stroke volume; and (iii) an evaluation of the pulsatile pressures in both the ventricle and the major arteries to consider the timing of the ventricular ejection provided by opening of the ventricular valves. We hope these suggestions may help future clarification of the relative importance of passive arterial mechanical properties compared to autonomic regulation in determining intracardiac shunts in both amphibians and reptiles. Copyright © 2017 Elsevier GmbH. All rights reserved.
Kapral, M K; Silver, F L
1999-01-01
OBJECTIVE: To develop guidelines for the use of echocardiography in the investigation of patients with stroke. OPTIONS: (1) Routine transthoracic echocardiography (TTE); (2) routine transesophageal echocardiography (TEE); (3) routine TTE followed by TEE if the TTE findings are noncontributory; (4) selective TTE or TEE in patients with cardiac disease who would not otherwise receive anticoagulant therapy. OUTCOMES: This article reviews the available evidence on the yield of TTE and TEE in detecting cardiac sources of cerebral emboli in patients with stroke, the effectiveness of treatment for cardiac sources of emboli and the effectiveness of screening echocardiography for secondary stroke prevention. EVIDENCE: MEDLINE was searched for relevant articles published from January 1966 to April 1998; also reviewed were additional articles identified from the bibliographies and citations obtained from experts. BENEFITS, HARMS AND COSTS: Echocardiography can detect intracardiac masses (thrombus, vegetation or tumour) in about 4% (with TTE) to 11% (with TEE) of stroke patients. The yield is lower among patients without clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (less than 2%) than among patients with clinical evidence of cardiac disease (less than 19%). The risks of echocardiography to patients are small. TTE has virtually no risks, and TEE is associated with cardiac, pulmonary and bleeding complications in 0.18%. Patients with an identified intracardiac thrombus are at increased risk for embolic events (absolute risk uncertain, range 0%-38%), and this appears to be reduced with anticoagulant therapy (absolute risk reduction uncertain). Anticoagulant therapy carries a risk of major hemorrhage of 1% to 3% per year. The overall effectiveness of echocardiography in the prevention of recurrent stroke is unknown. VALUES: The strength of evidence was evaluated using the methods of the Canadian Task Force on Preventive Health Care. RECOMMENDATIONS: There is fair evidence to recommend echocardiography in patients with stroke and clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (grade B recommendation). There is insufficient evidence to recommend for or against TEE in patients with normal results of TTE (grade C recommendation). There is insufficient evidence to recommend for or against routine echocardiography in patients (including young patients) without clinical cardiac disease (grade C recommendation). Routine echocardiography is not recommended for patients with clinical cardiac disease who have independent indications for or contraindications to anticoagulant therapy (grade D recommendation). There is fair evidence to recommend anticoagulant therapy in patients with stroke and intracardiac thrombus (grade B recommendation). There is insufficient (no) evidence to recommend for or against any specific therapy for patent foramen ovale (grade C recommendation). VALIDATION: The findings of this analysis were reviewed through an iterative process by the members of the Canadian Task Force on Preventive Health Care. PMID:10551199
Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D
2000-02-29
To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length <300 ms). Intermittent sensing of far-field R waves during sinus tachycardia caused 27 inappropriate AT/AF detections; these detections lasted 2.6+/-2.0 minutes. AT/AF was detected continuously in 27 of 28 patients who had spontaneous episodes of AT/AF (96%). The device memory recorded 90 appropriate AT/AF episodes lasting >1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.
Quantifying the determinants of decremental response in critical ventricular tachycardia substrate.
Beheshti, Mohammadali; Nayyar, Sachin; Magtibay, Karl; Massé, Stéphane; Porta-Sanchez, Andreu; Haldar, Shouvik; Bhaskaran, Abhishek; Vigmond, Edward; Nanthakumar, Kumaraswamy
2018-05-28
Decremental response evoked with extrastimulation (DEEP) is a useful tool for determining diastolic return path of ventricular tachycardia (VT). Though a targeted VT ablation is feasible with this approach, determinants of DEEP response have not been studied OBJECTIVES: To elucidate the effects of clinically relevant factors, specifically, the proximity of the stimulation site to the arrhythmogenic scar, stimulation wave direction, number of channels open in the scar, size of the scar and number of extra stimuli on decrement and entropy of DEEP potentials. In a 3-dimensional bi-domain simulation of human ventricular tissue (TNNP cell model), an irregular subendocardial myopathic region was generated. An irregular channel of healthy tissue with five potential entry branches was shaped into the myopathic region. A bipolar electrogram was derived from two electrodes positioned in the centre of the myopathic region. Evoked delays between far-field and local Electrogram (EGM) following an extrastimulus (S1-S2, 500-350 ms) were measured as the stimulation site, channel branches, and inexcitable tissue size were altered. Stimulation adjacent to the inexcitable tissue from the side opposite to the point-of-entry produces longest DEEP delay. The DEEP delay shortens when the stimulation point is farther away from the scar, and it decreases maximally when stimulation is done from a site beside a conduction barrier. Entropy increases with S2 when stimulation site is from farther away. An unprotected channel structure with multiple side-branch openings had shorter DEEP delay compared to a protected channel structure with a paucity of additional side-branch openings and a point-of-entry on the side opposite to the pacing source. Addition of a second shorter extrastimulus did not universally lead to higher DEEP delay CONCLUSIONS: Location and direction of the wavefront in relation to scar entry and size of scar determine the degree of evoked response while the number of extrastimuli has a small additional decremental effect. Copyright © 2018 Elsevier Ltd. All rights reserved.
Luther, Vishal; Linton, Nick W F; Jamil-Copley, Shahnaz; Koa-Wing, Michael; Lim, Phang Boon; Qureshi, Norman; Ng, Fu Siong; Hayat, Sajad; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa
2016-06-01
Post-infarct ventricular tachycardia is associated with channels of surviving myocardium within scar characterized by fractionated and low-amplitude signals usually occurring late during sinus rhythm. Conventional automated algorithms for 3-dimensional electro-anatomic mapping cannot differentiate the delayed local signal of conduction within the scar from the initial far-field signal generated by surrounding healthy tissue. Ripple mapping displays every deflection of an electrogram, thereby providing fully informative activation sequences. We prospectively used CARTO-based ripple maps to identify conducting channels as a target for ablation. High-density bipolar left ventricular endocardial electrograms were collected using CARTO3v4 in sinus rhythm or ventricular pacing and reviewed for ripple mapping conducting channel identification. Fifteen consecutive patients (median age 68 years, left ventricular ejection fraction 30%) were studied (6 month preprocedural implantable cardioverter defibrillator therapies: median 19 ATP events [Q1-Q3=4-93] and 1 shock [Q1-Q3=0-3]). Scar (<1.5 mV) occupied a median 29% of the total surface area (median 540 points collected within scar). A median of 2 ripple mapping conducting channels were seen within each scar (length 60 mm; initial component 0.44 mV; delayed component 0.20 mV; conduction 55 cm/s). Ablation was performed along all identified ripple mapping conducting channels (median 18 lesions) and any presumed interconnected late-activating sites (median 6 lesions; Q1-Q3=2-12). The diastolic isthmus in ventricular tachycardia was mapped in 3 patients and colocated within the ripple mapping conducting channels identified. Ventricular tachycardia was noninducible in 85% of patients post ablation, and 71% remain free of ventricular tachycardia recurrence at 6-month median follow-up. Ripple mapping can be used to identify conduction channels within scar to guide functional substrate ablation. © 2016 American Heart Association, Inc.
Yamabe, Hiroshige; Kanazawa, Hisanori; Ito, Miwa; Kaneko, Shozo; Ogawa, Hisao
2016-12-01
It remains unclear whether atrial fibrillation (AF) is maintained by the rotor. We evaluated the role of the rotor and examined its mechanism. Among 75 patients with AF (60 paroxysmal, 15 persistent AF) who underwent 3-dimensional noncontact left atrial mapping during AF, we examined the prevalence and location of rotor activation and elucidated its mechanism. Catheter ablation was performed in a stepwise fashion (linear roof lesion and complex fractionated atrial electrogram ablation after pulmonary vein [PV) isolation) until AF termination. Rotor activation was observed in 11 patients (14.7%; 10 paroxysmal and 1 persistent AF) (tachycardia cycle length 160.0 ± 19.8 ms). Rotors were observed transiently (duration 6128 ± 9094 ms) during AF at the roof (n = 5), septum (n = 3), and ostium of the left superior PV (n = 3). Five rotors circulated in clockwise and 6 in counterclockwise directions. The length of the block line at the center of the rotor was 15.2 ± 6.9 mm. The electrograms at the block line showed low-amplitude multiple deflections (n = 7) or double potentials (n = 4), and the amplitudes during rotor activation were significantly lower than those during sinus rhythm (0.27 ± 0.18 mV vs 1.22 ± 0.92 mV; P < .01). No conduction disturbances were found during sinus rhythm, suggesting that the central line of block was formed functionally. AF was terminated by PV isolation alone without additional lesions in patients with rotors. Functionally formed rotor activation was observed during AF in a limited number of patients. These rotor activations may not be related to AF maintenance, but rather may reflect a transient organization of random propagation. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
MR-based real time path planning for cardiac operations with transapical access.
Yeniaras, Erol; Navkar, Nikhil V; Sonmez, Ahmet E; Shah, Dipan J; Deng, Zhigang; Tsekos, Nikolaos V
2011-01-01
Minimally invasive surgeries (MIS) have been perpetually evolving due to their potential high impact on improving patient management and overall cost effectiveness. Currently, MIS are further strengthened by the incorporation of magnetic resonance imaging (MRI) for amended visualization and high precision. Motivated by the fact that real-time MRI is emerging as a feasible modality especially for guiding interventions and surgeries in the beating heart; in this paper we introduce a real-time path planning algorithm for intracardiac procedures. Our approach creates a volumetric safety zone inside a beating heart and updates it on-the-fly using real-time MRI during the deployment of a robotic device. In order to prove the concept and assess the feasibility of the introduced method, a realistic operational scenario of transapical aortic valve replacement in a beating heart is chosen as the virtual case study.
Snake spectacle vessel permeability to sodium fluorescein.
Bellhorn, Roy W; Strom, Ann R; Motta, Monica J; Doval, John; Hawkins, Michelle G; Paul-Murphy, Joanne
2018-03-01
Assess vascular permeability of the snake spectacle to sodium fluorescein during resting and shedding phases of the ecdysis cycle. Ball python (Python regius). The snake was anesthetized, and spectral domain optic coherence tomography was performed prior to angiographic procedures. An electronically controlled digital single-lens reflex camera with a dual-head flash equipped with filters suitable for fluorescein angiography was used to make images. Sodium fluorescein (10%) solution was administered by intracardiac injection. Angiographic images were made as fluorescein traversed the vasculature of the iris and spectacle. Individually acquired photographic frames were assessed and sequenced into pseudovideo image streams for further evaluation CONCLUSIONS: Fluorescein angiograms of the snake spectacle were readily obtained. Vascular permeability varied with the phase of ecdysis. Copious leakage of fluorescein occurred during the shedding phase. This angiographic method may provide diverse opportunities to investigate vascular aspects of snake spectacle ecdysis, dysecdysis, and the integument in general. © 2017 American College of Veterinary Ophthalmologists.
Intracardiac Penetrating Injury with Right Femoral Artery Embolism due to Blast Injury
Abuzaid, Ahmed Abdulaziz; Al-Abbasi, Thamer; Arekat, Zaid
2016-01-01
Embolization due to blast injury with projectiles entering the bloodstream from the heart is a rare event that is unlikely to be suspected during the initial assessment of trauma patients. We report a case in which a missile penetrating the heart chambers managed to embolize and occlude the right common femoral artery. This was successfully managed by means of a multidisciplinary approach that included exploration, cardiorrhaphy, and embolectomy. PMID:28400939
Intracardiac Penetrating Injury with Right Femoral Artery Embolism due to Blast Injury.
Abuzaid, Ahmed Abdulaziz; Al-Abbasi, Thamer; Arekat, Zaid
2016-01-01
Embolization due to blast injury with projectiles entering the bloodstream from the heart is a rare event that is unlikely to be suspected during the initial assessment of trauma patients. We report a case in which a missile penetrating the heart chambers managed to embolize and occlude the right common femoral artery. This was successfully managed by means of a multidisciplinary approach that included exploration, cardiorrhaphy, and embolectomy.
Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack
Abbasi Teshnizi, Mohammad; Ghorbanzadeh, Atefeh; Zirak, Nahid; Manafi, Babak
2017-01-01
Cardiac calcified amorphous tumors (CATs) are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal. PMID:28194283
Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack.
Abbasi Teshnizi, Mohammad; Ghorbanzadeh, Atefeh; Zirak, Nahid; Manafi, Babak; Moeinipour, Aliasghar
2017-01-01
Cardiac calcified amorphous tumors (CATs) are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal.
A Noninvasive Imaging Modality for Cardiac Arrhythmias
Burnes, John E.; Taccardi, Bruno; Rudy, Yoram
2007-01-01
Background The last decade witnessed an explosion of information regarding the genetic, molecular, and mechanistic basis of heart disease. Translating this information into clinical practice requires the development of novel functional imaging modalities for diagnosis, localization, and guided intervention. A noninvasive modality for imaging cardiac arrhythmias is not yet available. Present electrocardiographic methods cannot precisely localize a ventricular tachycardia (VT) or its key reentrant circuit components. Recently, we developed a noninvasive electrocardiographic imaging modality (ECGI) that can reconstruct epicardial electrophysiological information from body surface potentials. Here, we extend its application to image reentrant arrhythmias. Methods and Results Epicardial potentials were recorded during VT with a 490 electrode sock during an open chest procedure in 2 dogs with 4-day-old myocardial infarctions. Body surface potentials were generated from these epicardial potentials in a human torso model. Realistic geometry errors and measurement noise were added to the torso data, which were then used to noninvasively reconstruct epicardial isochrones, electrograms, and potentials with excellent accuracy. ECGI reconstructed the reentry pathway and its key components, including (1) the central common pathway, (2) the VT exit site, (3) lines of block, and (4) regions of slow and fast conduction. This allowed for detailed characterization of the reentrant circuit morphology. Conclusions ECGI can noninvasively image arrhythmic activation on the epicardium during VT to identify and localize key components of the arrhythmogenic pathway that can be effective targets for antiarrhythmic intervention. PMID:11044435
Iguchi, I; Kamiyama, K; Ohashi, T; Wang, X; Imanishi, J
1996-11-01
To establish a new method for evaluation of contact lens materials, we studied the porcine endothelial cell injury caused by dynamic contact (rotatory rubbing) with three kinds of hard contact lenses (HCL). The HCLs used were 1) PMMA HCL, 2) oxygen-permeable HCL composed of a graft copolymer of dextran derivative and methylmethacrylate (MMA) (Suncon Mild II, 12 Dk), and 3) oxygen-permeable-HCL composed of a copolymer of a monomer containing silicone, a monomer containing fluorine, and MMA (RGPL-A, 216 Dk). Cell injury rates were significantly different among these HCLs (Suncon Mild II < PMMA < RGPL-A) although there were no differences in rotatory rubbing forces. The smoothness of HCL surface, the qualities of injured cell layers observed by scanning electron microscopy, and the water wettability of HCLs were not correlated with cell injury rate. These results suggest that physicochemical properties of materials other than rotatory rubbing force, smoothness, and water wettability were involved in the cell injury. Our evaluation method for biomaterials that injure the corneal endothelial cells by dynamic contact should be very useful for the development of biomaterials or medical devices, including HCLs and intracardiac and urethral catheters.
Murine models of breast cancer bone metastasis
Wright, Laura E; Ottewell, Penelope D; Rucci, Nadia; Peyruchaud, Olivier; Pagnotti, Gabriel M; Chiechi, Antonella; Buijs, Jeroen T; Sterling, Julie A
2016-01-01
Bone metastases cause significant morbidity and mortality in late-stage breast cancer patients and are currently considered incurable. Investigators rely on translational models to better understand the pathogenesis of skeletal complications of malignancy in order to identify therapeutic targets that may ultimately prevent and treat solid tumor metastasis to bone. Many experimental models of breast cancer bone metastases are in use today, each with its own caveats. In this methods review, we characterize the bone phenotype of commonly utilized human- and murine-derived breast cell lines that elicit osteoblastic and/or osteolytic destruction of bone in mice and report methods for optimizing tumor-take in murine models of bone metastasis. We then provide protocols for four of the most common xenograft and syngeneic inoculation routes for modeling breast cancer metastasis to the skeleton in mice, including the intra-cardiac, intra-arterial, orthotopic and intra-tibial methods of tumor cell injection. Recommendations for in vivo and ex vivo assessment of tumor progression and bone destruction are provided, followed by discussion of the strengths and limitations of the available tools and translational models that aid investigators in the study of breast cancer metastasis to bone. PMID:27867497
Assessment of Xylazine for Euthanasia of Anoles (Anolis carolinensis and Anolis distichus)
Ascher, Jill M; Bates, Wendy; Ng, Julienne; Messing, Susan; Wyatt, Jeffrey
2012-01-01
Intracoelomic (IC) injection of xylazine was evaluated as a chemical euthanasia method for Anolis lizards (Anolis carolinensis or Anolis distichus). Lizards were allocated into 5 groups of 10 animals each. Each group was euthanized by one of these methods: 10 mg xylazine (100 mg/mL) IC; 10 mg xylazine and 0.5 mg acepromazine (10 mg/mL) IC; 10 mg xylazine IC followed by intracardiac injection of 0.1 mEq KCl (2 mEq/mL) once heart beats were no longer discernable by Doppler; 500 mg/kg 1% NaCO3-buffered MS222 solution IC followed by IC injection of 0.1 mL unbuffered 50% (v/v) MS222 solution (experimental groups); and 1.95 mg sodium pentobarbital, diluted 1:10 in sterile water (38.9 mg/mL) given IC (control group). Compared with those given sodium pentobarbital or MS222, lizards euthanized by using xylazine showed prolonged persistence of purposeful movement after cardiac arrest. Therefore, xylazine is not an acceptable alternative euthanasia agent for use in anoles. PMID:22330873
[Camera-cinematography of the heart (author's transl)].
Adam, W E; Meyer, G; Bitter, F; Kampmann, H; Bargon, G; Stauch, M
1975-07-01
By "camera-cinematography" of the heart, we mean an isotope method which permits detailed observation of cardiac mechanics without the use of a catheter. All that is necessary is an intravenous injection of 10 to 15 mCi 99mTc human serum albumen followed after ten minutes by a five to ten minute period of observation with a scintilation camera. At this time the isotope has become distributed in the blood. Variations in the precordial impulses correspond with intra-cardiac changes of blood volume during a cardiac cycle. Analysis of the R-wave provides adequate information of cyclical volume changes in limited portions of the heart. This is achieved by a monitor with a pseudo-3-dimensional display; contraction and relaxation of the myocardium can be shown for any chosen longitudinal or horizontal diameter of the heart. Our programme allows simultaneous presentation of the movement of any point on the myocardium as a time-activity curve. The method is recommended as an addition to chest radiography, heart screening or cardiac kymography before carrying out cardiac catheterisation.
Assessment of xylazine for euthanasia of anoles (Anolis carolinensis and Anolis distichus).
Ascher, Jill M; Bates, Wendy; Ng, Julienne; Messing, Susan; Wyatt, Jeffrey
2012-01-01
Intracoelomic (IC) injection of xylazine was evaluated as a chemical euthanasia method for Anolis lizards (Anolis carolinensis or Anolis distichus). Lizards were allocated into 5 groups of 10 animals each. Each group was euthanized by one of these methods: 10 mg xylazine (100 mg/mL) IC; 10 mg xylazine and 0.5 mg acepromazine (10 mg/mL) IC; 10 mg xylazine IC followed by intracardiac injection of 0.1 mEq KCl (2 mEq/mL) once heart beats were no longer discernable by Doppler; 500 mg/kg 1% NaCO(3)-buffered MS222 solution IC followed by IC injection of 0.1 mL unbuffered 50% (v/v) MS222 solution (experimental groups); and 1.95 mg sodium pentobarbital, diluted 1:10 in sterile water (38.9 mg/mL) given IC (control group). Compared with those given sodium pentobarbital or MS222, lizards euthanized by using xylazine showed prolonged persistence of purposeful movement after cardiac arrest. Therefore, xylazine is not an acceptable alternative euthanasia agent for use in anoles.
Jaumdally, R J; Lip, G Y H; Patel, J V; MacFadyen, R J; Varma, C
2009-06-01
Nonesterified fatty acids (NEFA) and insulin have been implicated in the pathogenesis of diabetes mellitus (Type 2 diabetes) and coronary artery disease (CAD). We hypothesized that intracardiac levels of insulin and NEFA within the aortic root, coronary sinus and systemic venous levels would be different in patients with coronary atherosclerosis and/or diabetes. We also studied the metabolic cardiac response following percutaneous coronary intervention (PCI). A total of 67 subjects (42 males; mean age 60 +/- 11 years) were recruited, of which three groups were identified: Group I - those with no CAD or Type 2 diabetes (n = 17); Group II - those with CAD but no Type 2 diabetes (n = 40); and Group III - patients with Type 2 diabetes and CAD (n = 10). Of the whole cohort, 34 patients (51%) proceeded to PCI. NEFA and insulin levels were analysed using enzymatic colorimetric and a monoclonal immuno-autoanalyser techniques, respectively. Subsequently, fractional extraction (FFE) of both variables was calculated. Nonesterified fatty acids and insulin concentrations were lower in the aortic root versus coronary sinus (both P < 0.05). FFE of NEFA was 2x higher in Group I (P < 0.01) with a sevenfold reduction in insulin FFE in Group III. Following PCI, systemic NEFA levels increased significantly (P < 0.05) with no significant change seen within the coronary sinus (P = NS), whilst a reduction in insulin concentrations at all three sites was observed (all P < 0.01). No significant difference in FFE of NEFA was seen after PCI when comparing Groups II and III. There was a drop in insulin extraction in Group II (nondiabetic subjects, from 12% to -4%, P = 0.04), compared with an increase seen in Group III (Type 2 diabetes patients, from -4% to 3%, P = 0.03). There is an intracardiac gradient of NEFA and insulin in Groups I-III. Cardiac NEFA metabolism was higher in those with mild CAD compared with those with obstructive CAD whereas intracardiac insulin extraction was lower in Group III (diabetic) patients. PCI was associated with a systemic rise in NEFA, with a reduction in insulin levels and cardiac utilization, but these effects were blunted in diabetic patients.
Jones, Aled R; Krummen, David E; Narayan, Sanjiv M
2013-09-01
To develop electrocardiogram (ECG) tools to quantify the number of sources for atrial fibrillation (AF), i.e. spatially stable rotors and focal impulses, and whether they lie in right or left atrium. Intracardiac mapping has recently shown that paroxysmal and persistent AF is sustained by rotors or focal sources that are stable in location and thus targets for limited ablation [focal impulse and rotor modulation (FIRM)] to eliminate AF. Importantly, the numbers and locations of concurrent sources determine both the complexity of AF and the approach for ablation. In 36 AF patients (n = 29 persistent, 63 ± 9 years) in the CONventional ablation with or without Focal Impulse and Rotor Modulation (CONFIRM) trial, we developed phase lock (PL) to quantify spatial repeatability of ECG 'F-waves' between leads over time. Phase lock spectrally quantifies the angle θ between F-wave voltages in planes formed by ECG leads I, aVF, and V1 at successive points in time. We compared PL with ECG spectral dominant frequency (DF) and organizational index (OI) to characterize stable rotors and focal sources validated by intracardiac FIRM mapping. Focal impulse and rotor modulation ablation alone at ≤3 sources acutely terminated and rendered AF non-inducible or substantially slowed AF in 31 of 36 patients. Receiver operating characteristics of PL for this endpoint had area under the curve (AUC) = 0.72, and the optimum cut-point (PL = 0.09) had 74% sensitivity, 92% positive predictive value (PPV). Receiver operating characteristics areas for OI and DF were 0.50 and 0.58, respectively. Left (n = 28) or right (n = 3) atrial sources were localized by PL with AUC = 0.85, sensitivity 100%, PPV 30%, and negative predictive value 100%. Spectral DF provided AUC = 0.79. Notably, PL did not comigrate with diagnosis of paroxysmal or persistent AF (P = NS), unlike ECG DF. The novel metric of ECG PL identifies patients with fewer (≤3) or greater numbers of stable rotors/focal sources for AF, validated by intracardiac FIRM mapping, and localized them to right or left atria. These data open the possibility of using 12-lead ECG analyses to classify AF mechanistically and plan procedures for right- or left-sided FIRM ablation.
2013-10-01
echocardiography to determine bubble/shunt scores. We will also use nuclear medicine imaging to determine shunt fractions following acute exposures to... echocardiography while breathing hypoxic gas mixtures. – TASK COMPLETED. For Task #1.3 “Quantify shunt during hypoxic exposure with SPECT CT – PFO...subjects.” 19 PFO+ subjects have completed saline contrast echocardiography while breathing hypoxic gas mixtures for 30 min. One PFO+ subject that had
Kemaloğlu Öz, Tuğba; Elsayed, Mahmoud; Nanda, Navin C; Kalenderoğlu, Koray; Akyüz, Şükrü; Atasoy, Işıl; Ösken, Altuğ; Onuk, Tolga; Eren, Mehmet
2016-09-01
Intracardiac tuberculomas are extremely rare, and cardiac involvement in tuberculosis accounts for only 0.5% of extrapulmonary tuberculosis. We report for the first time incremental value of live/real time three-dimensional transesophageal echocardiography over two-dimensional transesophageal echocardiography in the assessment of a tuberculoma involving the left atrium and left atrial appendage. © 2016, Wiley Periodicals, Inc.
Electromagnetic Interference in a Private Swimming Pool: Case report.
Iskandar, Sandia; Lavu, Madhav; Atoui, Moustapha; Lakkireddy, Dhanunjaya
2015-01-01
Although current lead design and filtering capabilities have greatly improved, Electromagnetic Interference (EMI) from environmental sources has been increasingly reported in patients with Cardiac Implantable Electronic Device (CIED) [1]. Few cases of inappropriate intracardiac Cardioverter Defibrillator (ICD) associated with swimming pool has been described [2]. Here we present a case of 64 year old male who presented with an interesting EMI signal that was subsequently identified to be related to AC current leak in his swimming pool.
Intercostal drainage tube or intracardiac drainage tube?
Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath
2016-01-01
Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.
Transforming Growth Factor Beta Signaling in Growth of Estrogen-Insensitive Metastatic Bone Lesions
2012-01-01
survival [12]. These observations suggest that more aggressive basal- like breast cancers have the capacity to be stimulated by autocrine EGFR...EGF, and AREG, as well as Normal Goat IgG, were purchased from R&D Systems (Minneapolis, MN). PAR34 clone was a gift from PDL BioPharma , and was...found that many of the subclones had differing capacities to colonize various organs after intracardiac injection into mice (12, 119-123). Gene
Riedlbauchová, Lucie; Janoušek, Jan; Veselka, Josef
2013-06-01
Alcohol septal ablation and surgical myectomy represent accepted therapeutic options for treatment of symptomatic patients with hypertrophic obstructive cardiomyopathy. Long-term experience with radiofrequency ablation of arrhythmogenic substrates raised a question if this technique might be effective for left ventricular outflow tract (LVOT) gradient reduction. We report on a 63-year-old patient with recurrence of symptoms 1 year after alcohol septal ablation (ASA) leading originally to a significant reduction of both symptoms and gradient. Due to a new increase of gradient in the LVOT up to 200 mm Hg with corresponding worsening of symptoms and due to refusal of surgical myectomy by the patient, endocardial radiofrequency ablation of the septal hypertrophy (ERASH) was indicated. Radiofrequency ablation was performed in the LVOT using irrigated-tip ablation catheter; the target site was identified using intracardiac echocardiography and electroanatomical CARTO mapping. ERASH caused an immediate gradient reduction due to hypokinesis of the ablated septum. At 2-month follow-up exam, significant clinical improvement was observed, together with persistent gradient reduction assessed with Doppler echocardiography. Echocardiography and magnetic resonance revealed persistent septal hypokinesis and slight thinning of the ablated region. Septal ablation using radiofrequency energy may be a promising alternative or adjunct to the treatment of hypertrophic obstructive cardiomyopathy. Intracardiac echocardiography and electroanatomical CARTO mapping enable exact lesion placement and preservation of atrioventricular conduction.
Carpenter, Thomas M.; Rashid, M. Wasequr; Ghovanloo, Maysam; Cowell, David M. J.; Freear, Steven; Degertekin, F. Levent
2016-01-01
In real-time catheter based 3D ultrasound imaging applications, gathering data from the transducer arrays is difficult as there is a restriction on cable count due to the diameter of the catheter. Although area and power hungry multiplexing circuits integrated at the catheter tip are used in some applications, these are unsuitable for use in small sized catheters for applications like intracardiac imaging. Furthermore, the length requirement for catheters and limited power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper an alternative approach using Analog Time Division Multiplexing (TDM) is presented which addresses the cable restrictions of ultrasound catheters. A novel digital demultiplexing technique is also described which allows for a reduction in the number of analog signal processing stages required. The TDM and digital demultiplexing schemes are demonstrated for an intracardiac imaging system that would operate in the 4 MHz to 11 MHz range. A TDM integrated circuit (IC) with 8:1 multiplexer is interfaced with a fast ADC through a micro-coaxial catheter cable bundle, and processed with an FPGA RTL simulation. Input signals to the TDM IC are recovered with −40 dB crosstalk between channels on the same micro-coax, showing the feasibility of this system for ultrasound imaging applications. PMID:27116738
Rigatelli, Gianluca; Rigateli, Gianluca; Cardaioli, Paolo; Braggion, Gabriele; Aggio, Silvio; Giordan, Massimo; Magro, Beatrice; Nascimben, Alberto; Favaro, Alberto; Roncon, Loris; Rincon, Loris
2007-02-01
We sought to prospectively assess the role of transesophageal (TEE) and intracardiac echocardiography (ICE) in detecting potential technical difficulties or failures in patients submitted to interatrial shunts percutaneous closure. We prospectively enrolled 46 consecutive patients (mean age 35+/-28, 8 years, 30 female) referred to our center for catheter-based closure of interatrial shunts. All patients were screened with TEE before the intervention. Patients who met the inclusion criteria underwent ICE study before the closure attempt (40 patients). TEE detected potential technical difficulties in 22.5% (9/40) patients, whereas ICE detected technical difficulties in 32.5% (13/40 patients). In patients with positive TEE/ICE the procedural success (92.4% versus 100% and, P = ns) and follow-up failure rate (7.7% versus 0%, P = ns) were similar to patients with negative TEE/ICE, whereas the fluoroscopy time (7 +/- 1.2 versus 5 +/- 0.7 minutes, P < 0.03), the procedural time (41 +/- 4.1 versus 30 +/- 8.2 minutes, P +/- 0.03), and technical difficulties rate (23.1% versus 0%, P = 0.013) were higher. Differences between ICE and TEE in the evaluation of rims, measurement of ASD or fossa ovalis, and detection of venous valve and embryonic septal membrane remnants impacted on technical challenges and on procedural and fluoroscopy times but did not influence the success rate and follow-up failure rate.
Surgical treatment for infective endocarditis in elderly patients.
Ramírez-Duque, N; García-Cabrera, E; Ivanova-Georgieva, R; Noureddine, M; Lomas, J M; Hidalgo-Tenorio, C; Plata, A; Gálvez-Acebal, J; Ruíz-Morales, J; de la Torre-Lima, J; Reguera, J M; Martínez-Marcos, F J; de Alarcón, A
2011-08-01
We evaluate the clinical, echographic and prognostic characteristics of infective endocarditis (IE) in a large population of elderly patients, and the results of surgical approach. Multicentric, prospective, observational cohort study with 961 consecutive left-sided IE: 356 patients aged ≥65 years were compared with 605 younger. Indications for cardiac surgery, potential surgical risk, time and outcome, were compared. Hospital-acquired endocarditis, comorbidity, renal failure and septic shock were more frequent in elderly, but embolisms were less. Intracardiac destruction and ventricular failure were similar in both groups, but significantly fewer elderly patients underwent cardiac surgery (36% vs 51%; p < 0.01), and this group showed a worse outcome (43.2% of mortality vs 27% in younger; p < 0.01), resulting age as an independent predictor of mortality (OR: 1.02 CI95%: 1.01-1.03). Compared with medical treatment, surgery showed lower percentages of mortality compared with medical treatment (23.3% vs 31.3%; p = 0.03) in younger group, but a high mortality was observed with both procedures (47.6% vs 40.3%; p = 0.1) in the elderly. Although similar percentages of heart failure and intracardiac complications, increasing age is associated with higher mortality in IE. Lower rates of surgical treatment and a worse outcome after operation are common features in elderly patients. Copyright © 2011 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Jiang, Guo-ping; Ye, Jing-jing; He, Jin; Zhao, Lei; Peng, Xue-hui; He, Yu; Yang, Xiu-zhen
2006-07-01
To assess the accuracy of echocardiography in diagnosis of total anomalous pulmonary venous connection (TAPVC). A combination of suprasternal, parasternal, subcostal and apical views were employed to diagnose TAPVC and to trace the course of the anomalous pulmonary venous connection, the direction of the inter-atrial shunt, enlargement of right atrium (RA) and right ventricle (RV), superior and inferior vena cava. All pediatric patients underwent surgical repair. The results of echocardiography were compared with surgical findings. A total of 28 consecutive pediatric patients with suspected TAPVC were included in this study. The TAPVC diagnosis was confirmed in 26 cases after surgery, partial anomalous pulmonary venous connection (PAPVC) in one case, and Cor Triatriatum and possible TAPVC in another. The diagnostic accuracy of TAPVC by echocardiography in the study was 92.86%. There were 17 supracardiac TAPVC, 11 intracardiac TAPVC. In all patients, enlargement of the RA and RV, inter-atrial right-to-left shunt via atrial septal defects were documented in parasternal and subcostal views. Common pulmonary vein or four pulmonary vein direct to RA or via coronary sinus to RA were the draining sites of intracardiac TAPVC. The enlargement of left innominate vein-right superior vena cava draining to RA was seen in supracardiac TAPVC. A combination of suprasternal and subcostal multi-views in echocardiography can increase the diagnostic accuracy of TAPVC in pediatric patients.
Ikegami, Yukinori; Tanimoto, Kojiro; Inagawa, Kohei; Shiraishi, Yasuyuki; Fuse, Jun; Sakamoto, Munehisa; Momiyama, Yukihiko; Takatsuki, Seiji
2017-12-25
Intracardiac echocardiography (ICE) and cardiac computed tomography (CCT), in addition to standard transesophageal echocardiography (TEE), have been used to identify left atrial (LA) thrombi prior to ablation for atrial fibrillation (AF). The clinical advantages of this, however, remain unclear. This study therefore investigated the advantages of additional pre-procedural LA appendage (LAA) thrombus evaluation using ICE and the clinical value of CCT in persistent and long-standing persistent AF.Methods and Results:We analyzed data from 108 consecutive patients with persistent and long-standing persistent AF who were scheduled to undergo AF ablation. TEE was performed within 24 h prior to ablation. ICE was performed for 97 patients in whom a thrombus was not detected on TEE. CCT was performed in 95 patients. Thrombus or sludge was detected on TEE in 11 patients (10.3%), for whom ablation was cancelled. Four additional patients were diagnosed with LAA thrombus on ICE. When TEE and ICE were used as the reference for thrombus detection, the sensitivity, specificity, positive predictive value, and negative predictive value of CCT for identifying contrast defects in the LAA were 100%, 81.0%, 40.7%, and 100%, respectively. ICE combined with TEE increased the detection rate of LAA thrombi in patients with persistent and long-standing persistent AF. Moreover, CCT had high sensitivity and negative predictive value for LAA thrombus detection.
BMP7 Induces Dormancy of Prostatic Tumor Stem Cell in Bone
2012-10-01
the upper back of nude mice. Recombinant human BMP7 was peritumorally injected daily after implantation. Tumor growth was monitored weekly by...of BMP7 was administrated daily through i.v. after intracardiac injection of CSCs from PC3mm or C4-2B cells to the mice. As shown in Figure 5A...mice, and then BMP7 was administrated daily . BLI of representative mice in each group six weeks after implantation (A). Normalized BLI signals
Stoliarchuk, A A; Storozhuk, B G; Briskin, V R
1985-01-01
The authors studied the antiarrhythmic and antifibrillatory effects of the known antiarrhythmic agents and the new Soviet coronaroactive drug phenicaberan exhibiting an antiarrhythmic action. All the drugs were examined for side effects and the action on the central and intracardiac hemodynamics in patients with acute myocardial infarction. Recommendations have been given as to the choice of effective drugs for the prophylaxis of arrhythmias depending on the pattern of heart rhythm abnormality and the hemodynamics.
Ethanol and Mesolimbic Serotonin/Dopamine Interactions via 5-HT-1B Receptors
2005-03-01
finished with After completion of the dialysis, the animals were given infusion of 50 [tM of baclofen , a GABAB receptor agonist, an intracardiac...in the quickly, and 40-[tm-thick coronal sections were cut on a ipsilateral NACC after perfusion with baclofen was consid- freezing microtome, stained...triethylamine, 11.5% and appropriate accumbal DA responses to perfusion of the acetonitrile and 11.5% methanol (pH 5.6 with H3 PO4 ), VTA with baclofen were
Goldman, A P; Kotler, M N; Goldberg, S E; Parameswaran, R; Parry, W
1985-12-01
Doppler echocardiography was used to determine the site and size of a ventricular septal defect in a patient with a penetrating wound of the heart. Additional physiological measurements by Doppler study, including pulmonary artery pressure and degree of left-to-right shunting, were helpful in deciding on surgical closure of the defect as the definitive therapy in this patient. Associated intracardiac defects (e.g., mitral or tricuspid regurgitation) can be excluded by Doppler echocardiography.
Intracardiac tromboembolism during liver transplantation.
Longo, S; Palacios, M; Tinti, M E; Siri, J; de Brahi, J I; Cabrera Shulmeyer, M C
2018-03-20
We describe a case of intraoperative cardiac trombosis during orthotopic liver transplant surgery that resulted in intraoperative death. By using transesophageal echocardiography, the cause of the descompensation of the patient could be determined and the mechanism of trombus migration from thrombi from the venous circulation to the left heart was accurately observed. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Severe right ventricular hypertrophy in a patient with extracardiac and intracardiac shunt.
Pahuja, Mohit; Abidov, Aiden
2018-06-10
Cardiac MRI is a complementary and confirmatory modality to a clinical echocardiography in diagnosing patients with complex adult congenital heart disease, especially in presence of great vessel abnormalities. We present a unique case of a patient with pulmonary hypertension (PH), severe right ventricular hypertrophy, Gerbode defect, and a large patent ductus arteriosus (PDA). The diagnosis of PDA was not visualized on prior serial echocardiograms and discovered on a comprehensive cardiac MRI/Chest MR angiogram. © 2018 Wiley Periodicals, Inc.
Right Ventricular Thrombus with Behçet's Syndrome
Dogan, Sait M.; Birdane, Alparslan; Korkmaz, Cengiz; Ata, Necmi; Timuralp, Bilgin
2007-01-01
Behçet's syndrome is a chronic multisystem disease that presents with recurrent oral and genital ulceration and recurrent uveitis. Cardiac involvement is an extremely rare manifestation of this disorder. A 33-year-old man with Behçet's syndrome was admitted to our department with a history of cough, fever, chest pain, hemoptysis, and weight loss. Transthoracic and transesophageal echocardiography revealed a right ventricular thrombus. After 1 month of treatment with warfarin, cyclophosphamide, and corticosteroid, the intracardiac thrombus resolved. PMID:17948088
Dogan, Sait M; Birdane, Alparslan; Korkmaz, Cengiz; Ata, Necmi; Timuralp, Bilgin
2007-01-01
Behçet's syndrome is a chronic multisystem disease that presents with recurrent oral and genital ulceration and recurrent uveitis. Cardiac involvement is an extremely rare manifestation of this disorder. A 33-year-old man with Behçet's syndrome was admitted to our department with a history of cough, fever, chest pain, hemoptysis, and weight loss. Transthoracic and transesophageal echocardiography revealed a right ventricular thrombus. After 1 month of treatment with warfarin, cyclophosphamide, and corticosteroid, the intracardiac thrombus resolved.
Stöckigt, Florian; Brixius, Klara; Lickfett, Lars; Andrié, René; Linhart, Markus; Nickenig, Georg; Schrickel, Jan Wilko
2012-01-01
Introduction Beta-adrenoceptors (β-AR) play an important role in the neurohumoral regulation of cardiac function. Three β-AR subtypes (β1, β2, β3) have been described so far. Total deficiency of these adrenoceptors (TKO) results in cardiac hypotrophy and negative inotropy. TKO represents a unique mouse model mimicking total unselective medical β-blocker therapy in men. Electrophysiological characteristics of TKO have not yet been investigated in an animal model. Methods In vivo electrophysiological studies using right heart catheterisation were performed in 10 TKO mice and 10 129SV wild type control mice (WT) at the age of 15 weeks. Standard surface ECG, intracardiac and electrophysiological parameters, and arrhythmia inducibility were analyzed. Results The surface ECG of TKO mice revealed a reduced heart rate (359.2±20.9 bpm vs. 461.1±33.3 bpm; p<0.001), prolonged P wave (17.5±3.0 ms vs. 15.1±1.2 ms; p = 0.019) and PQ time (40.8±2.4 ms vs. 37.3±3.0 ms; p = 0.013) compared to WT. Intracardiac ECG showed a significantly prolonged infra-Hisian conductance (HV-interval: 12.9±1.4 ms vs. 6.8±1.0 ms; p<0.001). Functional testing showed prolonged atrial and ventricular refractory periods in TKO (40.5±15.5 ms vs. 21.3±5.8 ms; p = 0.004; and 41.0±9.7 ms vs. 28.3±6.6 ms; p = 0.004, respectively). In TKO both the probability of induction of atrial fibrillation (12% vs. 24%; p<0.001) and of ventricular tachycardias (0% vs. 26%; p<0.001) were significantly reduced. Conclusion TKO results in significant prolongations of cardiac conduction times and refractory periods. This was accompanied by a highly significant reduction of atrial and ventricular arrhythmias. Our finding confirms the importance of β-AR in arrhythmogenesis and the potential role of unspecific beta-receptor-blockade as therapeutic target. PMID:23133676
Wilkoff, B L; Kühlkamp, V; Volosin, K; Ellenbogen, K; Waldecker, B; Kacet, S; Gillberg, J M; DeSouza, C M
2001-01-23
One of the perceived benefits of dual-chamber implantable cardioverter-defibrillators (ICDs) is the reduction in inappropriate therapy due to new detection algorithms. It was the purpose of the present investigation to propose methods to minimize bias during such comparisons and to report the arrhythmia detection clinical results of the PR Logic dual-chamber detection algorithm in the GEM DR ICD in the context of these methods. Between November 1997 and October 1998, 933 patients received the GEM DR ICD in this prospective multicenter study. A total of 4856 sustained arrhythmia episodes (n=311) with stored electrogram and marker channel were classified by the investigators; 3488 episodes (n=232) were ventricular tachycardia (VT)/ventricular fibrillation (VF), and 1368 episodes (n=149) were supraventricular tachycardia (SVT). The overall detection results were corrected for multiple episodes within a patient with the generalized estimating equations (GEE) method with an exchangeable correlation structure between episodes. The relative sensitivity for detection of sustained VT and/or VF was 100.0% (3488 of 3488, n=232; 95% CI 98.3% to 100%), the VT/VF positive predictivity was 88.4% uncorrected (3488 of 3945, n=278) and 78.1% corrected (95% CI 73.3% to 82.3%) with the GEE method, and the SVT positive predictivity was 100.0% (911 of 911, n=101; 95% CI 96% to 100%). A structured approach to analysis limits the bias inherent in the evaluation of tachycardia discrimination algorithms through the use of relative VT/VF sensitivity, VT/VF positive predictivity, and SVT positive predictivity along with corrections for multiple tachycardia episodes in a single patient.
GPU-Based Real-Time Volumetric Ultrasound Image Reconstruction for a Ring Array
Choe, Jung Woo; Nikoozadeh, Amin; Oralkan, Ömer; Khuri-Yakub, Butrus T.
2014-01-01
Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense computational load required in synthetic beamforming. For fast imaging with a ring array, we developed graphics processing unit (GPU)-based, real-time image reconstruction software that exploits massive data-level parallelism in beamforming operations. The GPU-based software reconstructs and displays three cross-sectional images at 45 frames per second (fps). This frame rate is 4.5 times higher than that for our previously-developed multi-core CPU-based software. In an alternative imaging mode, it shows one B-mode image rotating about the axis and its maximum intensity projection (MIP), processed at a rate of 104 fps. This paper describes the image reconstruction procedure on the GPU platform and presents the experimental images obtained using this software. PMID:23529080
Leopaldi, Alberto M; Wrobel, Krzysztof; Speziali, Giovanni; van Tuijl, Sjoerd; Drasutiene, Agne; Chitwood, W Randolph
2018-01-01
Previously, cardiac surgeons and cardiologists learned to operate new clinical devices for the first time in the operating room or catheterization laboratory. We describe a biosimulator that recapitulates normal heart valve physiology with associated real-time hemodynamic performance. To highlight the advantages of this simulation platform, transventricular extruded polytetrafluoroethylene artificial chordae were attached to repair flail or prolapsing mitral valve leaflets. Guidance for key repair steps was by 2-dimensional/3-dimensional echocardiography and simultaneous intracardiac videoscopy. Multiple surgeons have assessed the use of this biosimulator during artificial chordae implantations. This simulation platform recapitulates normal and pathologic mitral valve function with associated hemodynamic changes. Clinical situations were replicated in the simulator and echocardiography was used for navigation, followed by videoscopic confirmation. This beating heart biosimulator reproduces prolapsing mitral leaflet pathology. It may be the ideal platform for surgeon and cardiologist training on many transcatheter and beating heart procedures. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zanchetta, Mario, E-mail: emodinacit@ulss15.pd.it; Rigatelli, Gianluca; Pedon, Luigi
To assess the accuracy and efficacy of intravascular ultrasound guidance obtained by an intracardiac ultrasound probe during complex aortic endografting. Between November 1999 and July 2002, 19 patients (5 female, 14 male; mean age 73.5 {+-} 2.1 years) underwent endovascular repair of thoracic (n = 10), complex abdominal (n = 6) and concomitant thoraco-abdominal (n = 3) aortic aneurysm. The most suitable size and configuration of the stent-graft were chosen on the basis of preoperative computed tomographic angiography (CTA) or magnetic resonance angiography (MRA). Intraoperative intravascular ultrasound imaging was obtained using a 9 Fr, 9 MHz intracardiac echocardiography (ICE) probe,more » 110 cm in length, inserted through a 10 Fr precurved long sheath. The endografts were deployed as planned by CTA or MRA. Before stent-graft deployment, the ICE probe allowed us to view the posterior aortic arch and descending thoraco-abdominal aorta without position-related artifacts, and to identify both sites of stent-graft positioning. After stent-graft deployment, the ICE probe allowed us to detect the need for additional modular components to internally reline the aorta in 11 patients, and to discover 2 incomplete graft expansions subsequently treated with adjunctive balloon angioplasty. In 1 patient, the ICE probe supported the decision that the patient was ineligible for the endovascular exclusion procedure. The ICE probe provides accurate information on the anatomy of the posterior aortic arch and thoracic and abdominal aortic aneurysms and a rapid identification of attachment sites and stent-graft pathology, allowing refinement and improvement of the endovascular strategy.« less
Vörös, Károly; Hetyey, Csaba; Reiczigel, Jeno; Czirok, Gábor Nagy
2009-06-01
The aim of the study was to establish normal reference echocardiographic values for three Hungarian dog breeds, and to determine the potential dependence of intracardiac parameters on body weight, age and gender. M-mode and two-dimensional echocardiography were performed on 95 clinically healthy dogs including 45 Hungarian Vizslas, 28 Mudis and 22 Hungarian Greyhounds. Linear intracardiac measurements included interventricular septal thickness (IVS), left ventricular internal diameter (LVID), left ventricular posterior wall thickness (LVPW) both in systole and diastole, as well as left atrial internal diameter (LAD), and aortic diameter (AOD) in early diastole. Fractional shortening (FS), end-diastolic and end-systolic left ventricular volumes (EDV and ESV), as well as LAD:AOD ratio were calculated from the linear parameters. Mean, range and standard deviation of measurements were calculated for each breed. Body weight positively correlated in all three breeds with all left ventricular dimensions, such as IVS d , IVS s , LVID d , LVIDD s , LVPW d and LVPW s parameters. LA values showed positive correlations to body weight in all three breeds. AOD and LA demonstrated a positive correlation with body weight in Hungarian Vizslas and Mudis, whilst the LAD:AOD ratio was related to body weight only in Mudis. Gender did not correlate with any of the measured echocardiographic parameters in any breeds. In Mudis, a positive correlation was found between the LAD: AOD ratio and age, as well as between the LAD: AOD ratio and E point to septal separation (EPSS).
Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.
Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam
2006-11-01
Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.
Zebrafish heart as a model to study the integrative autonomic control of pacemaker function
Stoyek, Matthew R.; Quinn, T. Alexander; Croll, Roger P.
2016-01-01
The cardiac pacemaker sets the heart's primary rate, with pacemaker discharge controlled by the autonomic nervous system through intracardiac ganglia. A fundamental issue in understanding the relationship between neural activity and cardiac chronotropy is the identification of neuronal populations that control pacemaker cells. To date, most studies of neurocardiac control have been done in mammalian species, where neurons are embedded in and distributed throughout the heart, so they are largely inaccessible for whole-organ, integrative studies. Here, we establish the isolated, innervated zebrafish heart as a novel alternative model for studies of autonomic control of heart rate. Stimulation of individual cardiac vagosympathetic nerve trunks evoked bradycardia (parasympathetic activation) and tachycardia (sympathetic activation). Simultaneous stimulation of both vagosympathetic nerve trunks evoked a summative effect. Effects of nerve stimulation were mimicked by direct application of cholinergic and adrenergic agents. Optical mapping of electrical activity confirmed the sinoatrial region as the site of origin of normal pacemaker activity and identified a secondary pacemaker in the atrioventricular region. Strong vagosympathetic nerve stimulation resulted in a shift in the origin of initial excitation from the sinoatrial pacemaker to the atrioventricular pacemaker. Putative pacemaker cells in the sinoatrial and atrioventricular regions expressed adrenergic β2 and cholinergic muscarinic type 2 receptors. Collectively, we have demonstrated that the zebrafish heart contains the accepted hallmarks of vertebrate cardiac control, establishing this preparation as a viable model for studies of integrative physiological control of cardiac function by intracardiac neurons. PMID:27342878
2012-01-01
Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875
Interatrial septum pacing guided by three-dimensional intracardiac echocardiography.
Szili-Torok, Tamas; Kimman, Geert Jan P; Scholten, Marcoen F; Ligthart, Jurgen; Bruining, Nico; Theuns, Dominic A M J; Klootwijk, Peter J; Roelandt, Jos R T C; Jordaens, Luc J
2002-12-18
Currently, the interatrial septum (IAS) pacing site is indirectly selected by fluoroscopy and P-wave analysis. The aim of the present study was to develop a novel approach for IAS pacing using intracardiac echocardiography (ICE). Interatrial septum pacing may be beneficial for the prevention of paroxysmal atrial fibrillation. Cross-sectional images are acquired during a pull-back of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram- and respiration-gated technique. Both atria are then reconstructed using three-dimensional (3D) imaging. Using an "en face" view of the IAS, the desired pacing site is selected. Following lead placement and electrical testing, another 3D reconstruction is performed to verify the final lead position. Twelve patients were included in this study. The IAS pacing was achieved in all patients including six suprafossal (SF) and six infrafossal (IF) lead locations all confirmed by 3D imaging. The mean duration times of atrial lead implantation and fluoroscopy were 70 +/- 48.9 min and 23.7 +/- 20.6 min, respectively. The IAS pacing resulted in a significant reduction of the P-wave duration as compared to sinus rhythm (98.9 +/- 19.3 ms vs. 141.3 +/- 8.6 ms; p < 0.002). The SF pacing showed a greater reduction of the P-wave duration than IF pacing (59.4 +/- 6.6 ms vs. 30.2 +/- 13.6 ms; p < 0.004). Three-dimensional ICE is a feasible tool for guiding IAS pacing.
Prabhu, Sandeep; Voskoboinik, Aleksandr; McLellan, Alex J A; Peck, Kah Y; Pathik, Bhupesh; Nalliah, Chrishan J; Wong, Geoff R; Azzopardi, Sonia M; Lee, Geoffrey; Mariani, Justin; Ling, Liang-Han; Taylor, Andrew J; Kalman, Jonathan M; Kistler, Peter M
2017-10-01
The right atrium (RA) is readily accessible; however, it is unclear whether changes in the RA are representative of the LA. We performed detailed biatrial electroanatomic mapping to determine the electrophysiological relationship between the atria. Consecutive patients with persistent AF underwent biatrial electroanatomical mapping with a contact force catheter acquiring points with a CF >10 g prior to ablation. Points were analyzed for tissue voltage, complex electrograms, low voltage (<0.5 mV), scar (<0.05 mV), and conduction velocity (CV). Forty patients (mean age 59 ± 9.2 years, AF duration 12.9 ± 9.2 months, LA area: 28 ± 5.2, RA area: 25 ± 6.4 mm 2 , LVEF: 44 ± 15%) underwent mapping during CS pacing. Bipolar voltage (R = 0.57, P <0.001), unipolar voltage (R = 0.68, P <0.001), low voltage (<0.5 nV) (R = 0.48, P = 0.002), fractionation (R = 0.73, P <0.001), and CV (R = 0.49, P = 0.001) correlated well between atria. There was no difference in global bipolar voltage (LA 1.89 ± 0.77 vs. RA 1.77 ± 0.57 mV, P = 0.57); complex electrograms (LA 20% vs. RA 20%, P = 0.99) or low voltage (LA 15% vs. RA 16%, P = 0.84). Global unipolar voltage was significantly higher in the LA compared to the RA (2.95 ± 1.14 vs. 2.28 ± 0.65 mV, P = 0.002) and CV was significantly slower in the RA compared to the LA (0.93 ± 0.15 m/s vs. 1.01 ± 0.19 m/s, P = 0.001). AF is associated with remodeling processes affecting both atria. The more accessible RA provides an insight into the biatrial process associated with AF in various disease states without trans-septal access. © 2017 Wiley Periodicals, Inc.
Pathik, Bhupesh; Lee, Geoffrey; Sacher, Frédéric; Haïssaguerre, Michel; Jaïs, Pierre; Massoullié, Grégoire; Derval, Nicolas; Sanders, Prashanthan; Kistler, Peter; Kalman, Jonathan M
2017-08-01
Evidence for epicardial-endocardial breakthrough (EEB) is derived from mapping inferences in patients with atrial fibrillation who may also have focal activations. The purpose of this study was to investigate whether EEB could be discerned during stable right atrial (RA) macroreentry using high-density high-spatial resolution 3-dimensional mapping. Macroreentry was diagnosed using 3-dimensional mapping and entrainment. Bipolar maps were reviewed for EEB defined as (1) presence of focal endocardial activation with radial spread unaccounted for by an endocardial wavefront and (2) present with the same timing on every tachycardia cycle. The EEB site was always in proximity to a line of endocardial conduction slowing or block. Distance and conduction velocity from the line of block to the EEB site was calculated. Electrograms at EEB sites were individually analyzed for morphology and to confirm direction of activation. Entrainment was performed at EEB sites. Twenty-six patients were studied. Fourteen examples of EEB were seen: 11 at the posterior RA (4 at the superior portion of the posterior wall and 7 at the inferior section) and 1 each at the cavotricuspid isthmus postablation, RA septum, and inferolateral RA. The mean area of the EEB site was 0.6 ± 0.2 cm 2 . A mean of 79.5% ± 18.6% of unipolar electrograms at the EEB site demonstrated an rS morphology. The mean distance and conduction velocity from the line of endocardial block to the EEB site at the posterior RA was 13.6 ± 2.3 mm and 59.3 ± 12.3 cm/s, respectively. In 4 patients, entrainment demonstrated that EEB sites were within the circuit and in 1 of these patients critical to arrhythmia maintenance. Activation maps during tachycardia and coronary sinus pacing demonstrated EEB at the same anatomic site. EEB sites were demonstrated in stable atrial macroreentry supported by systematic entrainment confirmation and demonstration of the same phenomenon during pacing. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Fink, Thomas; Schlüter, Michael; Heeger, Christian-Hendrik; Lemes, Christine; Maurer, Tilman; Reissmann, Bruno; Riedl, Johannes; Rottner, Laura; Santoro, Francesco; Schmidt, Boris; Wohlmuth, Peter; Mathew, Shibu; Sohns, Christian; Ouyang, Feifan; Metzner, Andreas; Kuck, Karl-Heinz
2017-07-01
Pulmonary vein isolation (PVI) for persistent atrial fibrillation is associated with limited success rates and often requires multiple procedures to maintain stable sinus rhythm. In the prospective and randomized Alster-Lost-AF trial (Ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation), we sought to assess, in patients with symptomatic persistent or long-standing persistent atrial fibrillation, the outcomes of initial ablative strategies comprising either stand-alone PVI (PVI-only approach) or a stepwise approach of PVI followed by complex fractionated atrial electrogram ablation and linear ablation (Substrate-modification approach). Patients were randomized 1:1 to stand-alone PVI or PVI plus substrate modification. The primary study end point was freedom from recurrence of any atrial tachyarrhythmia, outside a 90-day blanking period, at 12 months. A total of 124 patients were enrolled, with 118 patients included in the analysis (61 in the PVI-only group, 57 in the Substrate-modification group). Atrial tachyarrhythmias recurred in 28 PVI-only group patients and 24 Substrate-modification group patients, for 1-year freedom from tachyarrhythmia recurrence after a single ablation procedure of 54% (95% confidence interval, 43%-68%) in the PVI-only and 57% (95% confidence interval, 46%-72%) in the Substrate-modification group ( P =0.86). Twenty-four patients in the PVI-only group (39%) and 18 in the Substrate-modification group (32%) were without arrhythmia recurrence and off antiarrhythmic drug therapy at the end of the 12-month follow-up. In patients with persistent and long-standing persistent atrial fibrillation, no significant difference was observed in 12-month freedom from atrial tachyarrhythmias between an index ablative approach of stand-alone PVI and a stepwise approach of PVI plus complex fractionated atrial electrogram and linear ablation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00820625. © 2017 American Heart Association, Inc.
4D MUSIC CMR: value-based imaging of neonates and infants with congenital heart disease.
Nguyen, Kim-Lien; Han, Fei; Zhou, Ziwu; Brunengraber, Daniel Z; Ayad, Ihab; Levi, Daniel S; Satou, Gary M; Reemtsen, Brian L; Hu, Peng; Finn, J Paul
2017-04-03
4D Multiphase Steady State Imaging with Contrast (MUSIC) acquires high-resolution volumetric images of the beating heart during uninterrupted ventilation. We aim to evaluate the diagnostic performance and clinical impact of 4D MUSIC in a cohort of neonates and infants with congenital heart disease (CHD). Forty consecutive neonates and infants with CHD (age range 2 days to 2 years, weight 1 to 13 kg) underwent 3.0 T CMR with ferumoxytol enhancement (FE) at a single institution. Independently, two readers graded the diagnostic image quality of intra-cardiac structures and related vascular segments on FE-MUSIC and breath held FE-CMRA images using a four-point scale. Correlation of the CMR findings with surgery and other imaging modalities was performed in all patients. Clinical impact was evaluated in consensus with referring surgeons and cardiologists. One point was given for each of five key outcome measures: 1) change in overall management, 2) change in surgical approach, 3) reduction in the need for diagnostic catheterization, 4) improved assessment of risk-to-benefit for planned intervention and discussion with parents, 5) accurate pre-procedural roadmap. All FE-CMR studies were completed successfully, safely and without adverse events. On a four-point scale, the average FE-MUSIC image quality scores were >3.5 for intra-cardiac structures and >3.0 for coronary arteries. Intra-cardiac morphology and vascular anatomy were well visualized with good interobserver agreement (r = 0.46). Correspondence between the findings on MUSIC, surgery, correlative imaging and autopsy was excellent. The average clinical impact score was 4.2 ± 0.9. In five patients with discordant findings on echo/MUSIC (n = 5) and catheter angiography/MUSIC (n = 1), findings on FE-MUSIC were shown to be accurate at autopsy (n = 1) and surgery (n = 4). The decision to undertake biventricular vs univentricular repair was amended in 2 patients based on FE-MUSIC findings. Plans for surgical approaches which would have involved circulatory arrest were amended in two of 28 surgical cases. In all 28 cases requiring procedural intervention, FE-MUSIC provided accurate dynamic 3D roadmaps and more confident risk-to-benefit assessments for proposed interventions. FE-MUSIC CMR has high clinical impact by providing accurate, high quality, simple and safe dynamic 3D imaging of cardiac and vascular anatomy in neonates and infants with CHD. The findings influenced patient management in a positive manner.
Comparison of tissue processing methods for microvascular visualization in axolotls.
Montoro, Rodrigo; Dickie, Renee
2017-01-01
The vascular system, the pipeline for oxygen and nutrient delivery to tissues, is essential for vertebrate development, growth, injury repair, and regeneration. With their capacity to regenerate entire appendages throughout their lifespan, axolotls are an unparalleled model for vertebrate regeneration, but they lack many of the molecular tools that facilitate vascular imaging in other animal models. The determination of vascular metrics requires high quality image data for the discrimination of vessels from background tissue. Quantification of the vasculature using perfused, cleared specimens is well-established in mammalian systems, but has not been widely employed in amphibians. The objective of this study was to optimize tissue preparation methods for the visualization of the microvascular network in axolotls, providing a basis for the quantification of regenerative angiogenesis. To accomplish this aim, we performed intracardiac perfusion of pigment-based contrast agents and evaluated aqueous and non-aqueous clearing techniques. The methods were verified by comparing the quality of the vascular images and the observable vascular density across treatment groups. Simple and inexpensive, these tissue processing techniques will be of use in studies assessing vascular growth and remodeling within the context of regeneration. Advantages of this method include: •Higher contrast of the vasculature within the 3D context of the surrounding tissue •Enhanced detection of microvasculature facilitating vascular quantification •Compatibility with other labeling techniques.
Acute renal infarction from a cardiac thrombus.
Nasser, Nicola J; Abadi, Sobhi; Azzam, Zaher S
2007-11-01
A 53-year-old man presented to hospital 2 hours after the abrupt onset of left upper abdominal pain. He was treated with analgesics and discharged after 4 hours of observation, but presented to another hospital 2 hours later with severe left abdominal pain. His past medical history included ischemic dilated cardiomyopathy due to recurrent myocardial infarction. Physical examination, electrocardiography, laboratory investigations, contrast-enhanced computed tomography, and transesophageal echocardiography. Renal artery thromboembolism resulting from dilated cardiomyopathy, severely reduced cardiac function and an intracardiac thrombus. Anticoagulation with unfractionated heparin followed by enoxaparin and warfarin.
Transcatheter intervention for the treatment of congenital cardiac defects.
Grifka, R G
1997-01-01
Cardiac catheterization has an illustrious history, originating in 1929 when Werner Forsmann, a surgical resident, performed a heart catheterization on himself. Transcatheter interventional procedures have been performed since the 1960s. The 1st intracardiac procedure to become standard therapy was a balloon atrial septostomy. Skeptics attacked this innovative procedure. However, the balloon septostomy procedure soon became the standard emergency procedure for certain congenital heart defects, and was the impetus for other investigators in the field of transcatheter intervention. We will discuss transcatheter treatment for congenital vascular stenoses and vascular occlusion. Images PMID:9456482
[Ultrasound scattering properties of Albunex microspheres].
Takamoto, T; Shiina, T
1998-04-01
In Japan, clinical and basic investigations of Albunex were started from 1989, and was firstly approved by the government as a commercially available contrast agent for the cardiovascular disorders. Although it has recently evacuated from the market, its acoustic properties proven by the many investigators were valuable for preparation of the second generation of contrast agents. Therefore, we summarized our data of the ultrasonic properties of Albunex both in vitro and experimental dog studies using RF signals. In conclusion, Albunex was a extremely sensitive blood flow tracer in evaluating intracardiac blood flow as well as intramyocardial perfusion.
Interventional Cardiology: What's New?
Scansen, Brian A
2017-09-01
Interventional cardiology in veterinary medicine continues to expand beyond the standard 3 procedures of patent ductus arteriosus occlusion, balloon pulmonary valvuloplasty, and transvenous pacing. Opportunities for fellowship training; advances in equipment, including high-resolution digital fluoroscopy, real-time 3-dimensional transesophageal echocardiography, fusion imaging, and rotational angiography; ultrasound-guided access and vascular closure devices; and refinement of techniques, including cutting and high-pressure ballooning, intracardiac and intravascular stent implantation, septal defect occlusion, transcatheter valve implantation, and hybrid approaches, are likely to transform the field over the next decade. Copyright © 2017 Elsevier Inc. All rights reserved.
Khuri-Yakub, B T; Oralkan, Omer; Nikoozadeh, Amin; Wygant, Ira O; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O'Donnell, Matthew; Truong, Uyen; Sahn, David J
2010-01-01
Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics.
Bethune, M
2007-08-01
Echogenic intracardiac focus and choroid plexus cysts are common findings at the midtrimester ultrasound. These findings have been linked with an increased risk of Down syndrome and trisomy 18. Most fetuses with these findings will, however, not have chromosomal abnormalities, especially when these findings are isolated. Patients experience considerable anxiety when informed of these findings and require extensive counselling in order to minimize anxiety not only about aneuploidy but also about the structure and development of the heart and brain. Although early studies showed an association with aneuploidies, several recent studies have cast doubt on this association. Many of the early studies were carried out in high-risk populations or in populations that had not had the benefit of other screening tests. Many Australian and New Zealand patients will access screening tests designed to detect these aneuploidies before presenting for a midtrimester ultrasound. Patients who have been screened by nuchal translucency, maternal serum screening or some combination of the two will already have had most cases of Down syndrome and trisomy 18 detected, and any soft marker found will almost certainly be a false positive. It is time to rethink the management of these markers. Recent evidence indicates that if these markers are found in isolation in an otherwise low-risk pregnancy, then there is minimal or no increase in the risk of Down syndrome or trisomy 18: these markers should be considered normal variants. The Australian Association of Obstetrical and Gynaecological Ultrasonologists consensus statement on these markers is included.
Schlundt, Jennifer; Tzanova, Irene; Werner, Christian
2012-05-01
Since certain surgical procedures still require a sitting or reverse Trendelenburg position, it remains important to evaluate the risk for paradoxical embolization. Intracardiac shunting, the most common cause being a patent foramen ovale, can be excluded by contrast-enhanced transesophageal echocardiography. There are, however, less described cases which result from patency of intrapulmonary functional arteriovenous anastomoses and lead to extra-cardiac paradoxical air embolism during anesthesia. We report a unique case to increase awareness of this real and potentially dangerous complication. A 52-yr-old male was scheduled for resection of a tumour at the cerebellopontine angle. Preoperative evaluation excluded intracardiac shunts. During a craniotomy in the sitting position, recurrent venous air emboli entered the patient's right heart, leading to a sudden decline in end-tidal CO(2), an increase in PaCO(2), and a reduction of PaO(2). The exact source of surgical entrance could not be identified; therefore, the surgical wound was closed provisionally and the patient was repositioned supine to prevent further venous air emboli. During transition to the supine position, we observed clinically significant crossover of air into the left heart originating from the left pulmonary vein, as detected by transesophageal echocardiography. In all likelihood, the etiology was an opening of intrapulmonary right-to-left anastomoses. The patient recovered without neurological or pulmonary sequelae. In the presence of massive venous air emboli, intrapulmonary right-to-left paradoxical air emboli can occur while intraoperatively transitioning a patient from the sitting to the supine position.
Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott
2016-02-01
We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.
Stapf, Daniel; Franke, Andreas; Schreckenberg, Marcus; Schummers, Georg; Mischke, Karl; Marx, Nikolaus; Schauerte, Patrick; Knackstedt, Christian
2013-04-01
Three-dimensional (3D)-imaging provides important information on cardiac anatomy during electrophysiological procedures. Real-time updates of modalities with high soft-tissue contrast are particularly advantageous during cardiac procedures. Therefore, a beat to beat 3D visualization of cardiac anatomy by intracardiac echocardiography (ICE) was developed and tested in phantoms and animals. An electronic phased-array 5-10 MHz ICE-catheter (Acuson, AcuNav/Siemens Medical Solutions USA/64 elements) providing a 90° sector image was used for ICE-imaging. A custom-made mechanical prototype controlled by a servo motor allowed automatic rotation of the ICE-catheter around its longitudinal axis. During a single heartbeat, the ICE-catheter was rotated and 2D-images were acquired. Reconstruction into a 3D volume and rendering by a prototype software was performed beat to beat. After experimental validation using a rigid phantom, the system was tested in an animal study and afterwards, for quantitative validation, in a dynamic phantom. Acquisition of beat to beat 3D-reconstruction was technically feasible. However, twisting of the ICE-catheter shaft due to friction and torsion was found and rotation was hampered. Also, depiction of catheters was not always ensured in case of parallel alignment. Using a curved sheath for depiction of cardiac anatomy there was no congruent depiction of shape and dimension of static and moving objects. Beat to beat 3D-ICE-imaging is feasible. However, shape and dimension of static and moving objects cannot always be displayed with necessary steadiness as needed in the clinical setting. As catheter depiction is also limited, clinical use seems impossible.
Effects of septal pacing on P wave characteristics: the value of three-dimensional echocardiography.
Szili-Torok, Tamas; Bruining, Nico; Scholten, Marcoen; Kimman, Geert-Jan; Roelandt, Jos; Jordaens, Luc
2003-01-01
Interatrial septum (IAS) pacing has been proposed for the prevention of paroxysmal atrial fibrillation. IAS pacing is usually guided by fluoroscopy and P wave analysis. The authors have developed a new approach for IAS pacing using intracardiac echocardiography (ICE), and examined its effects on P wave characteristics. Cross-sectional images are acquired during pullback of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram- and respiration-gated technique. The right atrium and IAS are then three-dimensionally reconstructed, and the desired pacing site is selected. After lead placement and electrical testing, another three-dimensional reconstruction is performed to verify the final lead position. The study included 14 patients. IAS pacing was achieved at seven suprafossal (SF) and seven infrafossal (IF) lead locations, all confirmed by three-dimensional imaging. IAS pacing resulted in a significant reduction of P wave duration as compared to sinus rhythm (99.7 +/- 18.7 vs 140.4 +/- 8.8 ms; P < 0.01). SF pacing was associated with a greater reduction of P wave duration than IF pacing (56.1 +/- 9.9 vs 30.2 +/- 13.6 ms; P < 0.01). P wave dispersion remained unchanged during septal pacing as compared to sinus rhythm (21.4 +/- 16.1 vs 13.5 +/- 13.9 ms; NS). Three-dimensional intracardiac echocardiography can be used to guide IAS pacing. SF pacing was associated with a greater decrease in P wave duration, suggesting that it is a preferable location to decrease interatrial conduction delay.
Enriquez, Andres; Saenz, Luis C; Rosso, Raphael; Silvestry, Frank E; Callans, David; Marchlinski, Francis E; Garcia, Fermin
2018-05-22
The indications for catheter-based structural and electrophysiological procedures have recently expanded to more complex scenarios, in which an accurate definition of the variable individual cardiac anatomy is key to obtain optimal results. Intracardiac echocardiography (ICE) is a unique imaging modality able to provide high-resolution real-time visualization of cardiac structures, continuous monitoring of catheter location within the heart, and early recognition of procedural complications, such as pericardial effusion or thrombus formation. Additional benefits are excellent patient tolerance, reduction of fluoroscopy time, and lack of need for general anesthesia or a second operator. For these reasons, ICE has largely replaced transesophageal echocardiography as ideal imaging modality for guiding certain procedures, such as atrial septal defect closure and catheter ablation of cardiac arrhythmias, and has an emerging role in others, including mitral valvuloplasty, transcatheter aortic valve replacement, and left atrial appendage closure. In electrophysiology procedures, ICE allows integration of real-time images with electroanatomic maps; it has a role in assessment of arrhythmogenic substrate, and it is particularly useful for mapping structures that are not visualized by fluoroscopy, such as the interatrial or interventricular septum, papillary muscles, and intracavitary muscular ridges. Most recently, a three-dimensional (3D) volumetric ICE system has also been developed, with potential for greater anatomic information and a promising role in structural interventions. In this state-of-the-art review, we provide guidance on how to conduct a comprehensive ICE survey and summarize the main applications of ICE in a variety of structural and electrophysiology procedures. © 2018 American Heart Association, Inc.
Development of Mitral Stenosis After Mitral Valve Repair: Importance of Mitral Valve Area.
Chan, Kwan Leung; Chen, Shin-Yee; Mesana, Thierry; Lam, Buu Khanh
2017-12-01
The development of mitral stenosis (MS) is not uncommon after mitral valve (MV) repair for degenerative mitral regurgitation (MR), but the significance of MS in this setting has not been defined. We prospectively studied 110 such patients who underwent supine bicycle exercise testing to assess intracardiac hemodynamics at rest and at peak exercise. B-type natriuretic peptide (BNP) levels were measured at rest and after the exercise test. The patients also performed the 6-minute walk test and completed the 36-Item Short Form Survey (SF-36). Follow-up was performed by a review of the medical record and telephone interview. Of 110 patients, 22 had MS defined by a mitral valve area (MVA) ≤ 1.5 cm 2 . The resting and peak exercise mitral gradients and pulmonary artery systolic pressure were significantly higher in patients with MS compared with patients with an MVA > 1.5 cm 2 . BNP levels at rest and after exercise were also higher in the patients with MS, who also had lower exercise capacity and worse perception of well-being in 3 domains (physical function, vitality, and social function) on the SF-36. MVA had higher specificity and positive predictive value in predicting outcome events compared with a mean gradient of 3 or 5 mm Hg. In patients who had MV repair for degenerative MR, an MVA ≤ 1.5 cm 2 occurs in about one-fifth of patients and is associated with adverse intracardiac hemodynamics, lower exercise capacity, and adverse outcomes. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Faber, Thomas S; Gradinger, Robert; Treusch, Sven; Morkel, Carsten; Brachmann, Johannes; Bode, Christoph; Zehender, Manfred
2007-09-01
Current studies found an incidence of 12-31% ventricular tachyarrhythmias and sudden cardiac death during cardiac pacing months or even years after pacemaker insertion. MADIT(12) and MUSTT(13) demonstrated that patients with poor LV function after Myocardial infarction (MI) showing non-sustained ventricular tachycardia (nsVT) and inducibility during electrophysiologic testing benefit from an ICD. The present study was dedicated to assess the global incidence of non-sustained ventricular arrhythmias in a general population of pacemaker patients. Special regard was on patients with a potential ICD indication, e.g. those matching the MADIT/MUSTT criteria. Two hundred and thirty-one patients (72 +/- 11 years; 134 men) with an indication for dual chamber pacing entered the study. In all patients pacemaker systems capable of automatic storing of intracardiac electrocardiograms were implanted (Pulsar, Discovery, Guidant). Follow-up time was 15 months after inclusion. In 54 (25.7%) of 210 patients with at least one follow-up, episodes of nsVT were documented by stored electrocardiograms (up to >30 beats, >200 b.p.m.). Multiple-up to nine-episodes of ventricular tachycardia were retrieved in 31 of these patients. Three out of 14 patients with an LVEF <40% after MI presented nsVT during the follow-up. One of these patients received an ICD. A significant number of pacemaker patients present with ventricular tachycardia. Intracardiac electrocardiograms and alert functions from pacemakers may enhance physicians' awareness of the patient's intrinsic arrhythmic profile and help uncover underlying mechanisms of arrhythmias by storing the initiation of the arrhythmia.
Bhatla, Puneet; Tretter, Justin T; Ludomirsky, Achi; Argilla, Michael; Latson, Larry A; Chakravarti, Sujata; Barker, Piers C; Yoo, Shi-Joon; McElhinney, Doff B; Wake, Nicole; Mosca, Ralph S
2017-01-01
Rapid prototyping facilitates comprehension of complex cardiac anatomy. However, determining when this additional information proves instrumental in patient management remains a challenge. We describe our experience with patient-specific anatomic models created using rapid prototyping from various imaging modalities, suggesting their utility in surgical and interventional planning in congenital heart disease (CHD). Virtual and physical 3-dimensional (3D) models were generated from CT or MRI data, using commercially available software for patients with complex muscular ventricular septal defects (CMVSD) and double-outlet right ventricle (DORV). Six patients with complex anatomy and uncertainty of the optimal management strategy were included in this study. The models were subsequently used to guide management decisions, and the outcomes reviewed. 3D models clearly demonstrated the complex intra-cardiac anatomy in all six patients and were utilized to guide management decisions. In the three patients with CMVSD, one underwent successful endovascular device closure following a prior failed attempt at transcatheter closure, and the other two underwent successful primary surgical closure with the aid of 3D models. In all three cases of DORV, the models provided better anatomic delineation and additional information that altered or confirmed the surgical plan. Patient-specific 3D heart models show promise in accurately defining intra-cardiac anatomy in CHD, specifically CMVSD and DORV. We believe these models improve understanding of the complex anatomical spatial relationships in these defects and provide additional insight for pre/intra-interventional management and surgical planning.
Age-related location of manifest accessory pathway and clinical consequences.
Brembilla-Perrot, Béatrice; Huttin, Olivier; Olivier, Arnaud; Sellal, Jean Marc; Villemin, Thibaut; Manenti, Vladimir; Moulin-Zinsch, Anne; Marçon, François; Simon, Gauthier; Andronache, Marius; Beurrier, Daniel; de Chillou, Christian; Girerd, Nicolas
2015-01-01
Accessory pathway (AP) ablation is not always easy. Our purpose was to assess the age-related prevalence of AP location, electrophysiological and prognostic data according to this location. Electrophysiologic study (EPS) was performed in 994 patients for a pre-excitation syndrome. AP location was determined on a 12 lead ECG during atrial pacing at maximal preexcitation and confirmed at intracardiac EPS in 494 patients. AP location was classified as anteroseptal (AS)(96), right lateral (RL)(54), posteroseptal (PS)(459), left lateral (LL)(363), nodoventricular (NV)(22). Patients with ASAP or RLAP were younger than patients with another AP location. Poorly-tolerated arrhythmias were more frequent in patients with LLAP than in other patients (0.009 for ASAP, 0.0037 for RLAP, <0.0001 for PSAP). Maximal rate conducted over AP was significantly slower in patients with ASAP and RLAP than in other patients. Malignant forms at EPS were more frequent in patients with LLAP than in patients with ASAP (0.002) or PSAP (0.001). Similar data were noted when AP location was confirmed at intracardiac EPS. Among untreated patients, poorly-tolerated arrhythmia occurred in patients with LLAP (3) or PSAP (6). Failures of ablation were more frequent for AS or RL AP than for LL or PS AP. AS and RLAP location in pre-excitation syndrome was more frequent in young patients. Maximal rate conducted over AP was lower than in other locations. Absence of poorly-tolerated arrhythmias during follow-up and higher risk of ablation failure should be taken into account for indications of AP ablation in children with few symptoms.
Slow adaptation of ventricular repolarization as a cause of arrhythmia?
Bueno-Orovio, A; Hanson, B M; Gill, J S; Taggart, P; Rodriguez, B
2014-01-01
This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". Adaptation of the QT-interval to changes in heart rate reflects on the body-surface electrocardiogram the adaptation of action potential duration (APD) at the cellular level. The initial fast phase of APD adaptation has been shown to modulate the arrhythmia substrate. Whether the slow phase is potentially proarrhythmic remains unclear. To analyze in-vivo human data and use computer simulations to examine effects of the slow APD adaptation phase on dispersion of repolarization and reentry in the human ventricle. Electrograms were acquired from 10 left and 10 right ventricle (LV/RV) endocardial sites in 15 patients with normal ventricles during RV pacing. Activation-recovery intervals, as a surrogate for APD, were measured during a sustained increase in heart rate. Observed dynamics were studied using computer simulations of human tissue electrophysiology. Spatial heterogeneity of rate adaptation was observed in all patients. Inhomogeneity in slow APD adaptation time constants (Δτ(s)) was greater in LV than RV (Δτ(s)(LV) = 31.8 ± 13.2, Δτ(s)(RV) = 19.0 ± 12.8 s , P< 0.01). Simulations showed that altering local slow time constants of adaptation was sufficient to convert partial wavefront block to block with successful reentry. Using electrophysiological data acquired in-vivo in human and computer simulations, we identify heterogeneity in the slow phase of APD adaptation as an important component of arrhythmogenesis.
Fatemi, Marjaneh; Le Gal, Grégoire; Blanc, Jean-Jacques; Mansourati, Jacques; Etienne, Yves
2011-01-01
Cardiac resynchronization therapy (CRT) has been demonstrated to improve symptoms and survival in patients with left ventricular (LV) systolic dysfunction and dyssynchrony. To achieve this goal, the LV lead should be positioned in a region of delayed contraction. We hypothesized that pacing at the site of late electrical activation was also associated with long-term response to CRT. We conducted a retrospective study on 72 CRT patients. For each patient, we determined the electrical delay (ED) from the onset of QRS to the epicardial EGM and the ratio of ED to QRS duration (ED/QRS duration). After a followup of 30 ± 20 months, 47 patients responded to CRT. Responders had a significantly longer ED and greater ratio of ED/QRS duration than nonresponders. An ED/QRS duration ≥0.38 predicted a response to CRT with 89% specificity and 53% sensitivity. PMID:21403903
Macedo, Paula G; Kapa, Suraj; Mears, Jennifer A; Fratianni, Amy; Asirvatham, Samuel J
2010-07-01
Ablation procedures for atrial fibrillation have become an established and increasingly used option for managing patients with symptomatic arrhythmia. The anatomic structures relevant to the pathogenesis of atrial fibrillation and ablation procedures are varied and include the pulmonary veins, other thoracic veins, the left atrial myocardium, and autonomic ganglia. Exact regional anatomic knowledge of these structures is essential to allow correlation with fluoroscopy and electrograms and, importantly, to avoid complications from damage of adjacent structures within the chest. We present this information as a series of 2 articles. In a prior issue, we have discussed the thoracic vein anatomy relevant to paroxysmal atrial fibrillation. In the present article, we focus on the atria themselves, the autonomic ganglia, and anatomic issues relevant for minimizing complications during atrial fibrillation ablation.
Petrovskiĭ, P F; Torbina, A M; Klemborskiĭ, A A
1988-09-01
A combined analysis of ventricular contractility and intracardiac hemodynamic compensatory mechanisms was carried out, on the basis of angiocardiographic findings, in 37 patients with rheumatic mitral incompetence. Atrial fibrillation aggravates essentially the defect's hemodynamics, while added tricuspid incompetence is accompanied by a certain off-loading in the lesser circulation network. A grossly perversed phasic structure of intramyocardial stress was noted, apparently being a compensatory mechanism. Reduced specific coronary flow and diastolic perfusion gradient in intact coronary arteries are shown to be causes of clinical angina.
Goldschmidt, P; Luyckx, J
1996-04-01
LOD, DSCG and NAAGA eye-drops were evaluated on experimentally-induced ocular active anaphylaxis in guinea pigs. Twelve animals per group were sensitized with egg albumin i.p. and challenged on the surface of the eye 14 days later. Two days before challenge, animals were treated with LOD, DSCG or NAAGA 4 times a day. Permeability indexes were calculated after intracardiac injection of Evans Blue. No effect on ocular active anaphylaxis was found with LOD nor with DSCG. NAAGA was able to significantly reduce blood-eye permeability indexes.
Two cases of scimitar variant.
Takeda, S; Imachi, T; Arimitsu, K; Minami, M; Hayakawa, M
1994-01-01
The scimitar sign is characteristic of partial anomalous pulmonary venous drainage into the inferior vena cava (IVC). We encountered two variant cases of scimitar sign. In one case, the scimitar vein entered both the IVC and the left atrium (LA) without any intracardiac shunts. Surgical repair was made by simple ligation of the scimitar vein to correct the left to right shunt. Retrograde balloon occlusion angiography of the scimitar vein was diagnostic. In the other case, the scimitar vein showed a meandering course, and then drained into the LA without any connection with the IVC, and surgical intervention was not required.
Yeo, H; Doyle, T; Saynor, R; Smith, G H
1986-01-01
After observations of cloudiness in the perfusion circuit at open intracardiac operations, laboratory experiments showed a precipitate in a Hartmann's solution (compound sodium lactate solution, Ringer-lactate) and sodium bicarbonate based priming fluid used for cardiopulmonary bypass. The precipitate was found to consist of calcium carbonate crystals. The crystals were not dissolved by adding plasma proteins, nor were they sufficiently cleared from the extracorporeal circuit by a 40 microns filter in the arterial line. The crystals may embolise in microvascular beds and thus be a cause of postoperative morbidity. The practice of adding sodium bicarbonate to the pump prime may be unnecessary. Images PMID:3010485
Khuri-Yakub, B. (Pierre) T.; Oralkan, Ömer; Nikoozadeh, Amin; Wygant, Ira O.; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N.; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O’Donnell, Matthew; Truong, Uyen; Sahn, David J.
2010-01-01
Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics. PMID:21097106
Dexmedetomidine Pharmacology in Neonates and Infants After Open Heart Surgery.
Su, Felice; Gastonguay, Marc R; Nicolson, Susan C; DiLiberto, MaryAnn; Ocampo-Pelland, Alanna; Zuppa, Athena F
2016-05-01
Dexmedetomidine is a highly selective α2-agonist with hypnotic, analgesic, and anxiolytic properties. Despite off-label administration, dexmedetomidine has found a niche in critically ill neonates and infants with congenital heart disease because of its minimal effects on respiratory function at sedative doses, facilitating early extubation and fast-track postoperative care. There are little pharmacokinetic data regarding newborns who have immature drug metabolizing capacity and who are at risk for reduced dexmedetomidine clearance and drug toxicity. The aim of this study was to determine the pharmacokinetics of dexmedetomidine in neonates and infants after open heart surgery. This study included 23 evaluable neonates (age, 1 day-1 month) and 36 evaluable infants (age, 1 month-24 months) after open heart surgery. Full-term neonates and infants requiring mechanical ventilation after open heart surgery received dexmedetomidine in a dose-escalation study. Dexmedetomidine was administered as a loading dose over 10 minutes followed by a continuous IV infusion up to 24 hours. Cohorts of 12 infants were enrolled sequentially to receive 0.35, 0.7, or 1 μg/kg dexmedetomidine followed by 0.25, 0.5, or 0.75 μg/kg/h dexmedetomidine, respectively. Cohorts of 9 neonates received 0.25, 0.35, or 0.5 μg/kg dexmedetomidine followed by 0.2, 0.3, or 0.4 μg/kg/h dexmedetomidine, respectively. Plasma dexmedetomidine concentrations were determined using a validated high-performance liquid chromatography-tandem mass spectrometry assay. A population nonlinear mixed effects modeling approach was used to characterize dexmedetomidine pharmacokinetics. Pharmacokinetic parameters of dexmedetomidine were estimated using a 2-compartment disposition model with weight allometrically scaled as a covariate on drug clearance, intercompartmental clearance, central and peripheral volume of distributions and age, total bypass time, and intracardiac shunting on clearance. Dexmedetomidine demonstrated a plasma drug clearance of 657 × (weight/70) mL/min, intercompartmental clearance of 6780 × (weight/70) mL/min, central volume of distribution of 88 × (weight/70) L and peripheral volume of distribution of 112 × (weight/70) L for a typical subject with age >1 month with a cardiopulmonary bypass time of 60 minutes and without right-to-left intracardiac shunt. Dexmedetomidine pharmacokinetics may be influenced by age during the neonatal period, weight, total bypass time, and presence of intracardiac shunt. Dexmedetomidine clearance is significantly diminished in full-term newborns and increases rapidly in the first few weeks of life. The dependence of clearance on age during the first few weeks of life reflects the relative immaturity of metabolic processes during the newborn period. Continuous infusions of up to 0.3 μg/kg/h in neonates and 0.75 μg/kg/h in infants were well tolerated after open heart surgery.
Marín Rodríguez, C; Sánchez Alegre, M L; Lancharro Zapata, Á; Alarcón Rodríguez, J
2015-01-01
Cardiac magnetic resonance imaging (cMRI) provides abundant morphological and functional information in the study of congenital heart disease. The functional information includes pulmonary output and systemic output; the ratio between these two (Qp/Qs) is the shunt fraction. After birth, in normal conditions the pulmonary output is practically identical to the systemic output, so Qp/Qs = 1. In patients with « shunts » between the systemic and pulmonary circulations, the ratio changes, and the interpretation of these findings varies in function of the location of the shunt (intracardiac or extracardiac) and of the associated structural or postsurgical changes. We review the concept of Qp/Qs; the methods to calculate it, with special emphasis on cMRI; and the meaning of the results obtained. We place special emphasis on the relevance of these findings depending on the underlying disease and the treatment the patient has undergone. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Cardiovascular applications of magnetic resonance imaging
Pflugfelder, Peter W.; Wisenberg, Gerald; Prato, Frank S.
1985-01-01
Magnetic resonance (MR) imaging is a unique imaging modality that is gaining rapid acceptance for a variety of medical indications. Diagnostic information is obtained noninvasively, without the potential hazards of ionizing radiation. The spatial resolution and anatomic detail of MR imaging rival those of other currently available imaging methods. By gating to an electrocardiographic signal cardiac imaging is possible. Since March 1983 the authors have had experience with cardiac MR imaging in both animals and humans. Cardiac anatomy is well shown by this technique, which allows detection and characterization of intracardiac masses, congenital heart disease and anomalies of the great vessels. Myocardial infarction has been detected in both animals and humans without the use of contrast agents, and acute cardiac transplant rejection has been visualized in an animal model. Limitations of MR imaging primarily have been lengthy imaging times and the sensitivity of the images to motion. With further investigation and experience this technique may become useful for studying a wide variety of cardiovascular disorders. ImagesFig. 2Fig. 3Fig. 4Fig. 5Fig. 6 PMID:3904969
Benefits and limitations of multimodality imaging in the diagnosis of a primary cardiac lymphoma.
Nijjar, Prabhjot Singh; Masri, Sofia Carolina; Tamene, Ashenafi; Kassahun, Helina; Liao, Kenneth; Valeti, Uma
2014-12-01
Primary cardiac tumors are far rarer than tumors metastatic to the heart. Angiosarcoma is the primary cardiac neoplasm most frequently detected; lymphomas constitute only 1% of primary cardiac tumors. We present the case of a 55-year-old woman with a recently diagnosed intracardiac mass who was referred to our institution for consideration of urgent orthotopic heart transplantation. Initial images suggested an angiosarcoma; however, a biopsy specimen of the mass was diagnostic for diffuse large B-cell lymphoma. The patient underwent chemotherapy rather than surgery, and she was asymptomatic 34 months later. We use our patient's case to discuss the benefits and limitations of multiple imaging methods in the evaluation of cardiac masses. Certain features revealed by computed tomography, cardiac magnetic resonance, and positron emission tomography can suggest a diagnosis of angiosarcoma rather than lymphoma. Cardiac magnetic resonance and positron emission tomography enable reliable distinction between benign and malignant tumors; however, the characteristics of different malignant tumors can overlap. Despite the great usefulness of multiple imaging methods for timely diagnosis, defining the extent of spread and the hemodynamic impact, and monitoring responses to treatment, we think that biopsy analysis is still warranted in order to obtain a correct histologic diagnosis in cases of suspected malignant cardiac tumors.
Price, Kenneth C.; Weiss, Jules M.; Hata, Daikichi; Smith, John R.
1955-01-01
Our experience with needle biopsy of the heart in dogs indicates that myocardial tissue can be sampled one or more times in each animal with comparative safety. Tamponade, pericarditis, serious arrhythmias, or myocardial infarction due to the interruption of coronary vessels was not observed. Excellent specimens were obtained for critical study by light and electron microscopy. Casten and Marsh (1) have used biochemical techniques to study myocardial tissue obtained in similar fashion. Histochemical methods would also be applicable. Although limited to animal studies at present, the technique may conceivably be adapted to the study of human disease. Myocardial puncture has been carried out (20–22) in patients for the recording of intracardiac pressures and for other diagnostic purposes without apparent harm. Our study of the myocardium of dogs by electron microscopy generally confirms the observations of other workers, except that presence of significant numbers of red blood cells in the extravascular spaces of the heart had not been previously described (and is possibly an artifact). Nevertheless, it is notable that the tissue cells, cellular membranes, and intracellular structures appeared to be intact and undistorted in the tissue specimens which were obtained, fixed, and examined by these methods. PMID:14367689
Volumetric real-time imaging using a CMUT ring array.
Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N; O'Donnell, Matthew; Sahn, David J; Khuri-Yakub, Butrus T
2012-06-01
A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device. This paper presents simulated and experimental imaging results for the described CMUT ring array. Three different imaging methods--flash, classic phased array (CPA), and synthetic phased array (SPA)--were used in the study. For SPA imaging, two techniques to improve the image quality--Hadamard coding and aperture weighting--were also applied. The results show that SPA with Hadamard coding and aperture weighting is a good option for ring-array imaging. Compared with CPA, it achieves better image resolution and comparable signal-to-noise ratio at a much faster image acquisition rate. Using this method, a fast frame rate of up to 463 volumes per second is achievable if limited only by the ultrasound time of flight; with the described system we reconstructed three cross-sectional images in real-time at 10 frames per second, which was limited by the computation time in synthetic beamforming.
Dyavanapalli, Jhansi; Rimmer, Katrina
2010-01-01
We have investigated the effects of the reactive oxygen species (ROS) donors hydrogen peroxide (H2O2) and tert-butyl hydroperoxide (t-BHP) on the intrinsic electrophysiological characteristics: ganglionic transmission and resting [Ca2+]i in neonate and adult rat intracardiac ganglion (ICG) neurons. Intracellular recordings were made using sharp microelectrodes filled with either 0.5 M KCl or Oregon Green 488 BAPTA-1, allowing recording of electrical properties and measurement of [Ca2+]i. H2O2 and t-BHP both hyperpolarized the resting membrane potential and reduced membrane resistance. In adult ICG neurons, the hyperpolarizing action of H2O2 was reversed fully by Ba2+ and partially by tetraethylammonium, muscarine, and linopirdine. H2O2 and t-BHP reduced the action potential afterhyperpolarization (AHP) amplitude but had no impact on either overshoot or AHP duration. ROS donors evoked an increase in discharge adaptation to long depolarizing current pulses. H2O2 blocked ganglionic transmission in most ICG neurons but did not alter nicotine-evoked depolarizations. By contrast, t-BHP had no significant action on ganglionic transmission. H2O2 and t-BHP increased resting intracellular Ca2+ levels to 1.6 ( ± 0.6, n = 11, P < 0.01) and 1.6 ( ± 0.3, n = 8, P < 0.001), respectively, of control value (1.0, ∼60 nM). The ROS scavenger catalase prevented the actions of H2O2, and this protection extended beyond the period of application. Superoxide dismutase partially shielded against the action of H2O2, but this was limited to the period of application. These data demonstrate that ROS decreases the excitability and ganglionic transmission of ICG neurons, attenuating parasympathetic control of the heart. PMID:20445155
Blanche, Coralie; Noble, Stéphane; Roffi, Marco; Testuz, Ariane; Müller, Hajo; Meyer, Philippe; Bonvini, John M; Bonvini, Robert F
2013-12-01
Platypnea-orthodeoxia syndrome (POS) is a rare clinical phenomenon, associating normal oxygen saturation in a supine position and arterial hypoxemia in an upright position. This pathology can be secondary to an intracardiac shunt, a pulmonary vascular shunt or a ventilation-perfusion mismatch. Cardiac POS occurs in the presence of a right-to-left cardiac shunt, most commonly through a patent foramen ovale (PFO). From our single-center prospective database of percutaneous PFO closure we identified five patients (4 females, mean age: 77 ± 11 years) out of 224 (2.2%) patients with a PFO who presented with a POS of cardiac origin. Transthoracic and transoesophageal echocardiographic examinations revealed the underlying mechanisms of POS and the diagnosis was confirmed by right-and-left cardiac catheterization (RLC) and by measuring serial blood oxygen saturation in the pulmonary veins and left atrium in supine and upright positions. PFO was associated with atrial septal aneurysm and a persistent prominent Eustachian valve in 3 patients. All patients underwent a successful percutaneous PFO closure without any immediate or subsequent complications (mean follow-up of 24 ± 18 months). Immediately after the procedure, mean arterial oxygen saturation improved from 83% ± 3 to 93% ± 2 in an upright position and symptoms disappeared. POS is a rare and under-diagnosed pathology that must be actively investigated in the presence of position-dependent hypoxemia. The diagnostic work-up must exclude other causes of hypoxemia and confirm the intracardiac shunt using either contrast echocardiography or RLC. For cardiac POS, percutaneous PFO closure is a safe and effective technique that immediately relieves orthodeoxia and patient symptoms. © 2013.
Ramaswamy, Prema; Rafii, Daniela; Osmolovsky, Marina; Agarwal, Arpit; Amirtharaj, Cynthia
2016-12-01
Evidence suggests an association between left heart obstructive lesions and dilated coronary sinus (DCS), but this has not been studied in fetuses. A retrospective review of fetal echocardiograms (FE) over an 8-year period was conducted, and patients with DCS were identified and confirmed postnatally. There were 5840 FE performed on 4920 women during this period. Of 49 patients with DCS, 22 had normal intracardiac anatomy and 27 patients had congenital heart disease (CHD) yielding an incidence of 4.6 % in the presence of CHD (27/584). Of 27 patients with DCS and CHD, approximately a third had either hypoplastic left ventricles and/or coarctations (10/27, 37 %). The incidence of left heart obstructive lesions was much higher in the presence of a DCS (37 % vs 45/557, 8 %, p < 0.0001). The odds ratio of left heart hypoplasia in fetuses with CHD and a DCS was 6.6 (95 % CI 2.8-15.3). Comparison of patients with postnatally confirmed coarctation with those with normal intracardiac anatomy with DCS, revealed that in the former, the right ventricle (p = 0.005), pulmonic valve annulus (p = 0.0001) and the tricuspid inflow were larger (p = 0.001) compared to corresponding left-sided structures. The size of the DCS was not significantly different between the two groups, but in the former, the DCS was more closely related to the posterior leaflet of the mitral valve and caused a significant diminution of the mitral inflow. Our study suggests a strong association, possibly causal, between left heart obstructive lesions and DCS in utero.
Stretched size of atrial septal defect predicted by intracardiac echocardiography.
Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Ho, Chi-Lin; Hwang, Betau
2010-01-01
The stretched size of an atrial septal defect (ASD) is important for device selection during transcatheter closure. However, balloon sizing carries potential risks such as hypotension, bradycardia, or laceration of the atrial septum. The aim of the present study was to investigate the accuracy of the predicted stretched size of ASD by intracardiac echocardiography (ICE). From December 2004 to November 2007, 136 consecutive patients with single secundum type ASD undergoing transcatheter closure of their defect using the Amplatzer septal occluder under ICE guidance were enrolled for analysis. There were 43 males and 93 females. The age ranged from 2.2 to 79.1 years with a median age of 13.4 years. The body weight ranged from 12.1 to 93.2 kg with a median body weight of 45.8 kg. The stretched size of ASD measured by a sizing plate was considered as the standard. ASD sizes measured by ICE in bicaval and short-axis views predicted the stretched size by formulae derived from linear regressions. The predicted stretched sizes obtained using 2 formulae, 1.34 x radicalbicaval xshort axis (formula 1) and 1.22 x larger diameter (formula 2), exhibited good agreement with the standard stretched size with Kappa values of 0.91 and 0.90, respectively. The accuracy rate of predicted stretched sizes within 2 mm, 3 mm, and 4 mm range of the standard size were 32.8%, 45.4%, and 57.7% (formula 1) and 33.1%, 50%, and 63.2% (formula 2). The stretched size of ASD predicted by ICE exhibited good agreement with the standard stretched size. This prediction provides helpful information, especially if balloon sizing cannot be adequately performed.
Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin
2011-08-01
Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando
2016-04-01
Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.
Cardiac function and exercise adaptation in 8 children with LPIN1 mutations.
Legendre, Antoine; Khraiche, Diala; Ou, Phalla; Mauvais, François-Xavier; Madrange, Marine; Guemann, Anne-Sophie; Jais, Jean-Philippe; Bonnet, Damien; Hamel, Yamina; de Lonlay, Pascale
2018-03-01
Lipin-1 deficiency is a major cause of rhabdomyolysis that are precipitated by febrile illness. The prognosis is poor, with one-third of patients dying from cardiac arrest during a crisis episode. Apart from acute rhabdomyolysis, most patients are healthy, showing normal clinical and cardiac ultrasound parameters. We report cardiac and exercise examinations of 8 children carrying two LPIN1 mutations. The examinations were performed outside of a myolysis episode, but one patient presented with fever during one examination. All but one patient displayed normal resting cardiac function, as determined by echocardiography. One patient exhibited slight left ventricular dysfunction at rest and a lack of increased stroke volume during cycle ramp exercise. During exercise, peripheral muscle adaptation was impaired in 2 patients compared to healthy controls: they presented an abnormal increase in cardiac output relative to oxygen uptake: dQ/dVO 2 =8.2 and 9.5 (>2DS of controls population). One patient underwent 2 exercise tests; during one test, the patient was febrile, leading to acute rhabdomyolysis in the following hours. He exhibited changes in recovery muscle reoxygenation parameters and an increased dQ/dVO 2 during exercise compared with that under normothermia (7.9 vs 6), which did not lead to acute rhabdomyolysis. The four patients assessed by cardiac 1 H-magnetic resonance spectroscopy exhibited signs of intracardiac steatosis. We observed abnormal haemodynamic profiles during exercise in 3/8 patients with lipin-1 deficiency, suggesting impaired muscle oxidative phosphorylation during exercise. Fever appeared to be an aggravating factor. One patient exhibited moderate cardiac dysfunction, which was possibly related to intracardiac stored lipid toxicity. Copyright © 2018 Elsevier Inc. All rights reserved.
Intracardiac ultrasound scanner using a micromachine (MEMS) actuator.
Zara, J M; Bobbio, S M; Goodwin-Johansson, S; Smith, S W
2000-01-01
Catheter-based intracardiac ultrasound offers the potential for improved guidance of interventional cardiac procedures. The objective of this research is the development of catheter-based mechanical sector scanners incorporating high frequency ultrasound transducers operating at frequencies up to 20 MHz. The authors' current transducer assembly consists of a single 1.75 mm by 1.75 mm, 20 MHz, PZT element mounted on a 2 mm by 2 mm square, 75 mum thick polyimide table that pivots on 3-mum thick gold plated polyimide hinges. The hinges also serve as the electrical connections to the transducer. This table-mounted transducer is tilted using a miniature linear actuator to produce a sector scan. This linear actuator is an integrated force array (IFA), which is an example of a micromachine, i.e., a microelectromechanical system (MEMS). The IFA is a thin (2.2 mum) polyimide membrane, which consists of a network of hundreds of thousands of micron scale deformable capacitors made from pairs of metallized polyimide plates. IFAs contract with an applied voltage of 30-120 V and have been shown to produce strains as large as 20% and forces of up to 8 dynes. The prototype transducer and actuator assembly was fabricated and interfaced with a GagePCI analog to digital conversion board digitizing 12 bit samples at a rate of 100 MSamples/second housed in a personal computer to create a single channel ultrasound scanner. The deflection of the table transducer in a low viscosity insulating fluid (HFE 7100, 3M) is up to +/-10 degrees at scan rates of 10-60 Hz. Software has been developed to produce real-time sector scans on the PC monitor.
Retrospectively gated intracardiac 4D flow MRI using spiral trajectories.
Petersson, Sven; Sigfridsson, Andreas; Dyverfeldt, Petter; Carlhäll, Carl-Johan; Ebbers, Tino
2016-01-01
To develop and evaluate retrospectively gated spiral readout four-dimensional (4D) flow MRI for intracardiac flow analysis. Retrospectively gated spiral 4D flow MRI was implemented on a 1.5-tesla scanner. The spiral sequence was compared against conventional Cartesian 4D flow (SENSE [sensitivity encoding] 2) in seven healthy volunteers and three patients (only spiral). In addition to comparing flow values, linear regression was used to assess internal consistency of aortic versus pulmonary net volume flows and left ventricular inflow versus outflow using quantitative pathlines analysis. Total scan time with spiral 4D flow was 44% ± 6% of the Cartesian counterpart (13 ± 3 vs. 31 ± 7 min). Aortic versus pulmonary flow correlated strongly for the spiral sequence (P < 0.05, slope = 1.03, R(2) = 0.88, N = 10), whereas the linear relationship for the Cartesian sequence was not significant (P = 0.06, N = 7). Pathlines analysis indicated good data quality for the spiral (P < 0.05, slope = 1.02, R(2) = 0.90, N = 10) and Cartesian sequence (P < 0.05, slope = 1.10, R(2) = 0.93, N = 7). Spiral and Cartesian peak flow rate (P < 0.05, slope = 0.96, R(2) = 0.72, N = 14), peak velocity (P < 0.05, slope = 1.00, R(2) = 0.81, N = 14), and pathlines flow components (P < 0.05, slope = 1.04, R(2) = 0.87, N = 28) correlated well. Retrospectively gated spiral 4D flow MRI permits more than two-fold reduction in scan time compared to conventional Cartesian 4D flow MRI, while maintaining similar data quality. © 2015 Wiley Periodicals, Inc.
Novel Surgical Technique for Coronary Fistulas With Proximal Origin.
Uchida, Tetsuro; Hamasaki, Azumi; Kuroda, Yoshinori; Ohba, Eiichi; Yamashita, Atsushi; Sadahiro, Mitsuaki
2017-09-01
Postoperative residual shunting is a significant concern in patients with coronary arteriovenous fistulas, especially in fistulas originating from the proximal left coronary artery, because of the limited surgical field. We report a case of fistulas originating from the proximal coronary artery in a 63-year-old woman in whom the ascending aorta and pulmonary artery were transected to obtain good surgical exposure. After complete transection of both great arteries, fistulas arising from the left main trunk were ligated externally, and their intracardiac openings were closed internally. Postoperative examination revealed no residual shunt flow. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Vascular plugs - A key companion to Interventionists - 'Just Plug it'.
Ramakrishnan, Sivasubramanian
2015-01-01
Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.
Arai, Marina; Fukamizu, Seiji; Kawamura, Iwanari; Miyazawa, Satoshi; Hojo, Rintaro; Sakurada, Harumizu; Hiraoka, Masayasu
2018-04-01
The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.
Aslan, Eyüp; Tanıdır, İbrahim Cansaran; Saygı, Murat; Onan, Sertaç Hanedan; Güzeltaş, Alper
2015-03-01
Scimitar syndrome is a rare disease associated with a right lung sequestration vascularised by arteries arising from the abdominal aorta and abnormal venous drainage into the inferior vena cava. The infantile form is generally presented with severe heart failure, pulmonary hypertension and respiratory distress. It may be associated with various intracardiac defects, including atrial septal defects, ventricular septal defects, patent ductus arteriosus or more complicated structural congenital heart defects. Here, we present a 2-month-old girl with Scimitar syndrome whose pulmonary arterial pressure decreased after transcatheter patent ductus arteriosus closure and embolization of the anomalous systemic arterial supply.
NASA Technical Reports Server (NTRS)
Katkov, V. Y.; Chesturkhin, V. V.; Zybin, O. K.; Sukhotskiy, S. S.; Abrosimov, S. V.; Utkin, V. N.
1981-01-01
The right parts of the heart and the radial artery were catheterized in healthy male volunteers before and 5 days after strict bedrest in antiorthostatic position of the body (-4.5 deg). After immobilization, most values of central circulation showed no essential changes; the only exceptions were indicates characterizing the inotropic myocardial condition. A shift in the direction of acidosis of a mixed character was noted in mixed venous blood, the beta lipoprotein content increased. A decrease in the arteriovenous difference in oxygen was encountered in blood draining from the heart (from the coronary sinus).
Kuroki, Kenji; Nogami, Akihiko; Igarashi, Miyako; Masuda, Keita; Kowase, Shinya; Kurosaki, Kenji; Komatsu, Yuki; Naruse, Yoshihisa; Machino, Takeshi; Yamasaki, Hiro; Xu, Dongzhu; Murakoshi, Nobuyuki; Sekiguchi, Yukio; Aonuma, Kazutaka
2018-04-01
Several conducting channels of ventricular tachycardia (VT) can be identified using voltage limit adjustment (VLA) of substrate mapping. However, the sensitivity or specificity to predict a VT isthmus is not high by using VLA alone. This study aimed to evaluate the efficacy of the combined use of VLA and fast-Fourier transform analysis to predict VT isthmuses. VLA and fast-Fourier transform analyses of local ventricular bipolar electrograms during sinus rhythm were performed in 9 postinfarction patients who underwent catheter ablation for a total of 13 monomorphic VTs. Relatively higher voltage areas on an electroanatomical map were defined as high voltage channels (HVCs), and relatively higher fast-Fourier transform areas were defined as high-frequency channels (HFCs). HVCs were classified into full or partial HVCs (the entire or >30% of HVC can be detectable, respectively). Twelve full HVCs were identified in 7 of 9 patients. HFCs were located on 7 of 12 full HVCs. Five VT isthmuses (71%) were included in the 7 full HVC+/HFC+ sites, whereas no VT isthmus was found in the 5 full HVC+/HFC- sites. HFCs were identical to 9 of 16 partial HVCs. Eight VT isthmuses (89%) were included in the 9 partial HVC+/HFC+ sites, whereas no VT isthmus was found in the 7 partial HVC+/HFC- sites. All HVC+/HFC+ sites predicted VT isthmus with a sensitivity of 100% and a specificity of 80%. Combined use of VLA and fast-Fourier transform analysis may be a useful method to detect VT isthmuses. © 2018 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.
2017-02-01
Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.
Shivkumar, Kalyanam; Ellenbogen, Kenneth A.; Hummel, John D.; Miller, John M.; Steinberg, Jonathan S.
2012-01-01
Catheter ablation of atrial fibrillation (AF) currently relies on eliminating triggers, and no reliable method exists to map the arrhythmia itself to identify ablation targets. The aim of this multicenter study was to define the use of Focal Impulse and Rotor Modulation (FIRM) for identifying ablation targets. METHODS We prospectively enrolled the first (n=14, 11 males) consecutive patients undergoing FIRM guided ablation for persistent (n=11) and paroxysmal AF at 5 centers. A 64 pole basket catheter was used for panoramic right and left atrial mapping during AF. AF electrograms were analyzed using a novel system to identify sustained rotors (spiral waves), or focal beats (centrifugal activation to surrounding atrium). Ablation was performed first at identified sources. The primary endpoints were acute AF termination or organization (>10 % cycle length prolongation). Conventional ablation was performed only after FIRM guided ablation. RESULTS 12/14 cases were mapped. AF sources were demonstrated in all patients (average of 1.9±0.8 per patient). Sources were left atrial in 18 cases, and right atrial in 5 cases, and 21/23 were rotors. FIRM guided ablation achieved the acute endpoint in all patients, consisting of AF termination in n=8 (4.9±3.9 min at the primary source), and organization in n=4. Total FIRM time for all patients was 12.3±8.6 min. CONCLUSIONS FIRM guided ablation revealed localized AF rotors/focal sources in patients with paroxysmal, persistent and longstanding persistent AF. Brief targeted FIRM guided ablation at a priori identified sites terminated or substantially organized AF in all cases prior to any other ablation. PMID:23130890
A CLINICAL METHOD FOR MAPPING AND QUANTIFYING BLOOD STASIS IN THE LEFT VENTRICLE
Rossini, Lorenzo; Martinez-Legazpi, Pablo; Vu, Vi; Fernández-Friera, Leticia; del Villar, Candelas Pèrez; Rodríguez-López, Sara; Benito, Yolanda; Borja, María-Guadalupe; Pastor-Escuredo, David; Yotti, Raquel; Ledesma-Carbayo, María J.; Kahn, Andrew M.; Ibáñez, Borja; Fernández-Avilès, Francisco; May-Newman, Karen; Bermejo, Javier; del Álamo, Juan C.
2015-01-01
In patients at risk of intraventricular thrombosis, the benefits of chronic anticoagulation therapy need to be balanced with the pro-hemorrhagic effects of therapy. Blood stasis in the cardiac chambers is a recognized risk factor for intracardiac thrombosis and potential cardiogenic embolic events. In this work, we present a novel flow image-based method to assess the location and extent of intraventricular stasis regions inside the left ventricle (LV) by digital processing flow-velocity images obtained either by phase-contrast magnetic resonance (PCMR) or 2D color-Doppler velocimetry (echo-CDV). This approach is based on quantifying the distribution of the blood Residence Time (TR) from time-resolved blood velocity fields in the LV. We tested the new method in illustrative examples of normal hearts, patients with dilated cardiomyopathy and one patient before and after the implantation of a left ventricular assist device (LVAD). The method allowed us to assess in-vivo the location and extent of the stasis regions in the LV. Original metrics were developed to integrate flow properties into simple scalars suitable for a robust and personalized assessment of the risk of thrombosis. From a clinical perspective, this work introduces the new paradigm that quantitative flow dynamics can provide the basis to obtain subclinical markers of intraventricular thrombosis risk. The early prediction of LV blood stasis may result in decrease strokes by appropriate use of anticoagulant therapy for the purpose of primary and secondary prevention. It may also have a significant impact on LVAD device design and operation set-up. PMID:26680013
Bansal, Neha; Kobayashi, Daisuke; Karpawich, Peter P
2017-11-11
A 14-year-old female was referred for severe pulmonary valve insufficiency after undergoing radiofrequency ablation for a right ventricular outflow tract tachycardia that originated in the proximal pulmonary artery at 10 years of age. Clinical records indicated that ablation was guided solely by electrograms and electroanatomical mapping. Due to myocardial tissue extensions, mapping failed to identify the level of the pulmonary valve annulus, which resulted in delivery of energy on the valve proper and into the pulmonary artery. She developed severe pulmonary valve insufficiency and moderate proximal pulmonary artery stenosis necessitating intravascular stent placement 4 years later with an associated transcatheter valve. Although the nonfluoroscopic approach during ablation has gained wide acceptance for use in children, this report highlights the benefits of adjunctive imaging to identify the precise location of the pulmonary valve when ablation therapy is contemplated in the right ventricle outflow tract. © 2017 Wiley Periodicals, Inc.
Periodontal Disease Is an Independent Predictor of Intracardiac Calcification
Pressman, Gregg S.; Qasim, Atif; Verma, Nitin; Arishiro, Kumiko; Notohara, Yasuhiro; Crudu, Vitalie; Figueredo, Vincent M.
2013-01-01
Background. Periodontitis is the most common chronic inflammatory condition worldwide and is associated with incident coronary disease. Hypothesis. We hypothesized that periodontal disease would also be associated with cardiac calcification, a condition which shares many risk factors with atherosclerosis and is considered a marker of subclinical atherosclerosis. Methods. Cross-sectional study at two sites (USA and Japan) involving subjects with both clinical echocardiograms and detailed dental examinations. Semiquantitative scoring systems were used to assess severity of periodontal disease and echocardiographic calcification. Results. Fifty-six of 73 subjects (77%) had cardiac calcifications, and 51% had moderate to severe periodontal disease (score > 2). In unadjusted analysis, a significant relationship between periodontal score and cardiac calcification (Spearman rho = 0.4, P = 0.001) was noted, with increases in mean calcification score seen across increasing levels of periodontal disease. On multivariate logistic regression, adjusted for age, gender, race, glomerular filtration rate, and traditional risk factors, this association remained significant (P = 0.024). There was no significant interaction by study site, race, or gender. Conclusions. In a multiracial population, we found a significant association between the degree of periodontal disease, a chronic inflammatory condition, and cardiac calcification. Further, higher periodontal scores were associated with greater degrees of calcification. PMID:24106721
[Traumatic tricuspid insufficiency. Apropos of 2 cases].
Ventre, F; Bertinchant, J P; Noblet, D; Frapier, J M; Carabasse, D; Nigond, J; Ledermann, B; Cohen, S; Joubert, P; Grolleau-Raoux, R
1995-06-01
The authors report two cases of tricuspid regurgitation by a ruptured anterior papillary muscle secondary to non-penetrating thoracic trauma. In the presence of suggestive clinical and electrocardiographic abnormalities (systolic murmur, right heart failure, right bundle branch block), echocardiography confirmed the tricuspid regurgitation, showed its mechanism and excluded any other intracardiac lesions. Tricuspid annuloplasty was performed in both cases because of the persistence of failure or degradation of the patient's clinical condition. Peroperative echocardiography was used to judge the quality of the surgical repair in both cases. Traumatic tricuspid regurgitation is a rare condition and the diagnosis is often delayed. Echocardiography is the investigation of choice and guides treatment which is essentially valvular repair in symptomatic patients.
Adult Wilms tumor: Case report.
Morabito, V; Guglielmo, N; Melandro, F; Mazzesi, G; Alesini, F; Bosco, S; Berloco, P B
2015-01-01
Wilms tumor (WT) occurs infrequently in adults. Even rarer is adult WT with extension by direct intravascular spread into the right side of the heart. The present report describes a WT with intracaval and intracardiac extension in a 38-year-young man. In addition, thrombus extension above the infrahepatic IVC represents a major technical topic for surgeons because of the possible occurrence of uncontrollable hemorrhages and tumor fragmentation. We report the results of a surgical approach to caval thrombosis including the isolation of the IVC from the liver as routinely performed during liver harvesting. The morphologic and immune-histochemical findings confirmed the diagnosis. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Shiose, Akira; Desai, Parag; Criner, Gerard J; Pai, Sheela; Steiner, Robert M; Kaiser, Larry R; Guy, T Sloane; Toyoda, Yoshiya
2014-01-01
A 77-year-old woman presented with shortness of breath 1 year after a right upper lobectomy for lung cancer. She showed a possible intracardiac metastasis on positron emission tomography scan. There was no other evidence of recurrence. The large right ventricular mass was associated with the right ventricle free wall, the apex, the papillary muscle, and the chordae to the tricuspid valve. After mass resection of the right ventricle, a one-and-a-half ventricular repair was performed with tricuspid valve replacement and defect closure. The patient was discharged on postoperative day 14 without complications and has been well for the first 3 months after the surgery.
Dilemma in clinical diagnosis of right ventricular masses.
Sušić, Livija; Baraban, Vedrana; Vincelj, Josip; Maričić, Lana; Ćatić, Jasmina; Blažeković, Robert; Manojlović, Spomenka
2017-07-08
Detection of an intracardiac mass always represents a clinical challenge. We present a 61-year-old female patient with symptoms of New York Heart Association class III. Two-dimensional transthoracic echocardiography revealed a hypoechogenic mass in the cavity of the dilated right ventricle (RV). Cardiac MRI described a pathologic structure of the RV free wall with pedunculated tumor in its cavity. Three months later, on a repeated echocardiography, there were three individual masses. The patient underwent surgery and the pathohistologic report demonstrated thrombotic masses. During the postoperative period, after reviewing all medical records, the conclusion was arrhythmogenic RV cardiomyopathy. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:362-369, 2017. © 2016 Wiley Periodicals, Inc.
Lyme carditis. Electrophysiologic and histopathologic study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reznick, J.W.; Braunstein, D.B.; Walsh, R.L.
1986-11-01
To further define the nature of Lyme carditis, electrophysiologic study and endomyocardial biopsy were performed in a patient with Lyme disease, whose principal cardiac manifestation was high-degree atrioventricular block. Intracardiac recording demonstrated supra-Hisian block and complete absence of an escape mechanism. Gallium 67 scanning demonstrated myocardial uptake, and right ventricular endomyocardial biopsy revealed active lymphocytic myocarditis. A structure compatible with a spirochetal organism was demonstrated in one biopsy specimen. It is concluded that Lyme disease can produce active myocarditis, as suggested by gallium 67 imaging and confirmed by endomyocardial biopsy. Furthermore, the presence of high-grade atrioventricular block in this diseasemore » requires aggressive management with temporary pacemaker and corticosteroid therapy.« less
Origins of Cardiovascular Surgery at the Mayo Clinic.
Arghami, Arman; Dearani, Joseph A; Schaff, Hartzell V; Puga, Francisco J; Daly, Richard C
2016-01-01
Sixty years ago, at the Mayo Clinic in Rochester, Minnesota, an ambitious group of pioneers, led by Dr John W. Kirklin and supported by a multidisciplinary team of physicians and technicians embarked on a planned series of surgical cases using a heart-lung machine to allow direct visualization of the inside of the opened human heart to repair otherwise fatal congenital intracardiac defects. Their success sparked the beginning of a new era of open-heart surgery. In this historical article, we discuss the contributions of a few key figures of this revolution and also share the story of the first successful cardiac surgery operation using cardiopulmonary bypass performed at Mayo Clinic. Copyright © 2016 Elsevier Inc. All rights reserved.
Cyanosis and Stroke due to Functional Cor Triatriatum Dexter in a Neonate.
León, Rachel L; Zaban, Nicholas B; Schamberger, Marcus S; Ho, Chang Y; Mietzsch, Ulrike
2018-01-01
Small remnants of the right valve of the sinus venosus are commonly found in adults, but the incidence and risk associated with these embryonic remnants in neonates are not well studied. The following report describes a cyanotic neonate with a large Eustachian valve remnant creating a functional cor triatriatum dexter who was initially diagnosed with persistent pulmonary hypertension of the newborn. The cyanosis in this infant improved over the first postnatal week with conservative management, but she suffered multifocal subcortical stroke, likely related to her intracardiac shunt. The clinical presentation and questions regarding long-term management of this rare diagnosis are explored. © 2018 S. Karger AG, Basel.
Total Artificial Heart as Rescue Therapy for Primary Graft Failure in an Infant.
Ziegler, Luke A; Sainathan, Sandeep; Morell, Victor O; Sharma, Mahesh S
2018-04-01
An infant unable to be weaned from cardiopulmonary bypass after orthotopic heart transplantation was cannulated for extracorporeal membrane oxygenation. During the next 3 days, allograft failure and intracardiac thrombosis necessitated cardiectomy. To provide acute mechanical circulatory support, artificial atrial chambers were constructed with Gore-Tex conduits and PediMag centrifugal pumps were connected to each by Berlin Heart EXCOR cannulae. The PediMag pumps were subsequently exchanged for 10-mL Berlin Heart EXCOR pumps. After 60 days of support by total artificial heart, the patient was bridged successfully to a second heart transplant. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ribo, Tang; Jianzeng, Dong; Xiaohui, Liu; Meisheng, Shang; Ronghui, Yu; Deyong, Long; Xin, Du; Junping, Kang; Jiahui, Wu; Man, Ning; Caihua, Sang; Chenxi, Jiang; Rong, Bai; Songnan, Li; Yan, Yao; Songnan, Wen; Changsheng, Ma
2015-08-01
To explore if CHA2DS2 VASc score can predict substrate for persistent atrial fibrillation ( AF) and outcome post catheter ablation of AF. From January 2011 to December 2012,116 patients underwent catheter ablation of persistent AF in our department and were enrolled in this study. CHA2DS2VASc score was calculated as follows: two points were assigned for a history of stroke or transient ischemic attack and age ≥ 75 and 1 point each was assigned for age ≥ 65, a history of hypertension, diabetes,recent cardiac failure, vessel disease, female. Left atrial geometry ( LA) was reconstructed with a 3.5 mm tip ablation catheter with fill-in threshold 10 in CARTO system. The mapping catheter was stabled at each endocardial location for at least 3 seconds for recording. The electrogram recordings at each endocardial location were analyzed with a custom software embedded in the CARTO mapping system. Interval confidence level (ICL) was used to characterize complex fractionated atrial electrograms (CFAEs) . As the default setting of the software, ICL more than or equal to 7 was considered sites with a highly repetitive CFAEs complex. CFAEs index was defined as the fraction of area of ICL more than or equal to 7 to the left atrial surface. The CFAEs index and outcome of catheter ablation among different CHA2DS2VASc groups were compared. Of the 116 patients, CHA2DS2VASc was 0 in 33 patients, 1 in 31 patients and ≥ 2 in 52 patients. Left atrial surface ((121.2 ± 18.9) cm2, (133.6 ± 23.8) cm2, (133.9 ± 16.1) cm2, P = 0.008), left atrial volume ((103.6 ± 24.8) ml, (118.3 ± 27.8) ml, (120.9 ± 20.9) ml, P = 0.005) and CFAEs index (44.6% ± 22.4%, 54.2% ± 22.2%, 58.7% ± 23.1%, P = 0.023) increased in proportion with increasing CHA2DS2VASc. ICLmax, ICLmin and CFAEs spatial distribution were similar among the three groups. During the mean follow-up of (13 ± 8) months, the recurrence rate were 36.4%, 35.5%, 55.8% among the three groups (P = 0.025). A high CHA2DS2VASc score is associated with extensive AF substrate and higher recurrence rate post catheter ablation of persistent AF.
Velasco, Alejandro; Siddiqui, Mohammed; Kreps, Eric; Kolakalapudi, Pavani; Dudenbostel, Tanja; Arora, Garima; Judd, Eric K; Prabhu, Sumanth D; Lloyd, Steven G; Oparil, Suzanne; Calhoun, David A
2018-06-04
Refractory hypertension (RfHTN) is an extreme phenotype of antihypertensive treatment failure defined as lack of blood pressure control with ≥5 medications, including a long-acting thiazide and a mineralocorticoid receptor antagonist. RfHTN is a subgroup of resistant hypertension (RHTN), which is defined as blood pressure >135/85 mm Hg with ≥3 antihypertensive medications, including a diuretic. RHTN is generally attributed to persistent intravascular fluid retention. It is unknown whether alternative mechanisms are operative in RfHTN. Our objective was to determine whether RfHTN is characterized by persistent fluid retention, indexed by greater intracardiac volumes determined by cardiac magnetic resonance when compared with controlled RHTN patients. Consecutive patients evaluated in our institution with RfHTN and controlled RHTN were prospectively enrolled. Exclusion criteria included advanced chronic kidney disease and masked or white coat hypertension. All enrolled patients underwent biochemical testing and cardiac magnetic resonance. The RfHTN group (n=24) was younger (mean age, 51.7±8.9 versus 60.6±11.5 years; P =0.003) and had a greater proportion of women (75.0% versus 43%; P =0.02) compared with the controlled RHTN group (n=30). RfHTN patients had a greater left ventricular mass index (88.3±35.0 versus 54.6±12.5 g/m 2 ; P <0.001), posterior wall thickness (10.1±3.1 versus 7.7±1.5 mm; P =0.001), and septal wall thickness (14.5±3.8 versus 10.0±2.2 mm; P <0.001). There was no difference in B-type natriuretic peptide levels and left atrial or ventricular volumes. Diastolic dysfunction was noted in RfHTN. Our findings demonstrate greater left ventricular hypertrophy without chamber enlargement in RfHTN, suggesting that antihypertensive treatment failure is not attributable to intravascular volume retention. © 2018 American Heart Association, Inc.
Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C
2018-01-01
Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.
Ferns, Sunita; Komarlu, Rukmini; Van Bergen, Andrew; Multani, Kanwar; Cui, Vivian Wei; Roberson, David A
2012-08-01
Multiple barriers to transthoracic echocardiography are present in critically ill infants immediately after surgery. Transesophageal echocardiography (TEE) is sometimes needed to obtain specific important information that transthoracic echocardiography fails to demonstrate. Formerly, the investigators used the AcuNav intracardiac echocardiographic (ICE) intravascular ultrasound transducer (8 Fr, 2.5 mm, 64-element crystal array, multifrequency [5.5-10 MHz], single longitudinal plane, linear phased array [Siemens Medical Solutions USA, Inc., Mountain View, CA]). Recently, the investigators have also used the microTEE transducer (8-mm transducer tip, 5.2-mm shaft, multifrequency [3-8 MHz], multiplane phased array, 32-element probe [Philips Medical Systems, Andover, MA]). Both transducers have two-dimensional, M-mode, color Doppler, and pulsed-wave and continuous-wave Doppler capabilities. The aim of this study was to compare the efficacy, safety, ease of insertion, capabilities, utilization, and cost of the AcuNav ICE transducer versus those of the microTEE transducer. A retrospective review of all 50 postoperative critically ill infants who underwent TEE using the AcuNav and microTEE in the past 5 years was conducted. TEE was performed as ordered by the attending physician to answer a specific question not answered by transthoracic echocardiography. In all cases, the clinical information sought was obtained. The AcuNav ICE transducer was safe, easy to insert through the transnasal route, and did not require paralysis; however, it had a limited number of echocardiographic views and had greater sterilization cost. The microTEE transducer had greater echocardiographic capabilities and lower sterilization cost; however, it was slightly more difficult to insert, had a few manageable complications, and required more sedation and paralysis. TEE in this setting has increased because of demonstrated efficacy and safety. Both the AcuNav ICE and microTEE transducers are useful and effective in this critical clinical scenario. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Gonzalez-Ruiz, Armando; Gargalianos-Kakolyris, Panayiotis; Timerman, Artur; Sarma, Jayanta; José González Ramallo, Víctor; Bouylout, Kamel; Trostmann, Uwe; Pathan, Rashidkhan; Hamed, Kamal
2015-06-01
The aim of this study was to evaluate the clinical outcomes and safety of daptomycin therapy in patients with serious Gram-positive infections. Patients were enrolled in the European Cubicin(®) Outcomes Registry and Experience (EU-CORE(SM)), a non-interventional, multicenter, observational registry. The real-world data were collected across 18 countries (Europe, Latin America, and Asia) for patients who had received at least one dose of daptomycin between January 2006 and April 2012. Two-year follow-up data were collected until 2014 for patients with endocarditis, intracardiac/intravascular device infection, osteomyelitis, or orthopedic device infection. A total of 6075 patients were enrolled. The most common primary infections were complicated skin and soft tissue infection (31.7%) and bacteremia (20.7%). Staphylococcus aureus was the most frequently reported pathogen (42.9%; methicillin-resistant S. aureus [MRSA], 23.2%), followed by Staphylococcus epidermidis and other coagulase-negative staphylococci (CoNS, 28.5%). The most commonly prescribed dose of daptomycin was 6 mg/kg/day (43.6%), and the median duration of therapy was 11 (range 1-300) days. Overall clinical success rate was 80.5%, and was similar whether daptomycin was used as first-line (82.9%) or second-line (79.2%) therapy. Clinical success rates were high in patients with S. aureus (83.9%; MRSA 83.0%) and CoNS (including S. epidermidis, 82.5%) infections. The majority of patients with endocarditis or intracardiac/intravascular device infection (86.7%) or osteomyelitis/orthopedic device infection (85.9%) had a sustained response during the 2-year follow-up period. There were no new or unexpected safety findings. Results from real-world clinical experience showed that daptomycin is a valuable therapeutic option in the management of various difficult-to-treat Gram-positive infections. This study was funded by Novartis Pharma AG.
Intracardiac thrombi in extracardiac disorders: an autopsy study.
Vaideeswar, Pradeep; Divate, Smita; Harke, Megha
2012-01-01
Intracardiac thrombi (ICT), more commonly encountered at autopsy, are well documented with underlying cardiovascular disease. Occurrence of ICT in systemic diseases without an intrinsic cardiac disorder is rare. The aim of this autopsy study was to highlight such an occurrence. From 1996 to 2010, cases with ICT unrelated to primary cardiac disorders were selected at autopsy and analyzed. Clinical and investigational data were obtained from the medical records. The location, morphology, size, and histological appearance of the thrombi were noted. The thrombi were then classified on the basis of their location, nature, and histology (fresh and/or organized); this was correlated with the clinical setting. Among a total of 11,724 autopsies performed in 15 years, 276 patients (2.4%) had ICT. Of these, 45 patients (0.4%) had ICT that were unrelated to primary cardiac diseases. There were 25 men and 20 women with a mean age of 46.1 years. Antemortem diagnosis was not made in any of these patients. Eight patients each (35.6%) showed isolated left-sided and multichambered involvement, while the rest of the hearts (64.4%) had thrombi in the right-sided chamber(s). The recognizable risk factors were underlying cancers (24.4%), prolonged immobilization (20%), systemic lupus erythematosus (6.7%), pregnancy (4.4%), nephropathy (4.4%), primary antiphospholipid antibody syndrome (2.2%), and ulcerative colitis (2.2%). However, 16 patients (35.7%) had no obvious predisposing factor, although investigations for prothrombotic markers had not been done. Diabetes mellitus, chronic alcoholism, and deep vein thrombosis of the lower limbs had been clinically documented in some of them. The cause of death in most patients (73.3%) had been related to pulmonary and/or systemic thromboembolism. This autopsy study emphasizes the great need for a higher index of suspicion of in situ thrombosis in the heart in hypercoagulable states so as to curtail the morbidity and mortality of the primary disease process. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mory, Cyril, E-mail: cyril.mory@philips.com; Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes; Auvray, Vincent
2014-02-15
Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method,more » which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.« less
[Aneurism of the subclavian artery associated with Turner's syndrome].
Lacombe, M; Esteva, B; Tillous-Borde, I; Lesèche, G
2004-04-01
Arterial aneurysms associated with Turner's syndrome are rare. We report a case of aneurysm of the left subclavian artery in a 16-year-old girl with Turner's syndrome. This patient was operated on: resection of the aneurysm, suture of the aortic arch and reimplantation of the subclavian artery in the left common carotid were performed. At 3-year follow-up, the evolution is favourable. Cardiovascular anomalies are observed in 50% of subjects with Turner's syndrome. This justifies complementary cardiac investigations in these patients. Congenital malformations (bicuspid aortic valve, aortic coarctation, intracardiac communications, valvular lesions) or acquired anomalies (arterial hypertension, aortic dissection) are frequent. Only one similar case of subclavian artery aneurysm has been reported until now. The risk of rupture justifies the surgical treatment.
Cardiac thrombosis as a manifestation of Behçet syndrome.
Louali, Fedoua El; Tamdy, Asmae; Soufiani, Aida; Oukerraj, Latifa; Omari, Driss; Bounjoum, Fadwa; Mekouar, Fadwa; Tazi-Mezalek, Zoubida; Bouhouch, Rachida; Zarzur, Jamila; Cherti, Mohamed
2010-01-01
Herein, we report 3 cases of Behçet syndrome that were accompanied by intracardiac thrombus. The 1st patient was a 30-year-old man who presented with dyspnea; a right atrial thrombus was identified upon transthoracic echocardiography. The 2nd patient was a 52-year-old man who was admitted for dyspnea; transthoracic echocardiography revealed an echogenic mass in the right ventricle. The 3rd patient was a 23-year-old man who was hospitalized for hemoptysis; the diagnosis of pulmonary embolism was made, and right ventricular thrombosis was found.Because these patients had no hemodynamic compromise, medical management consisting of immunosuppressive and anticoagulative therapy was adopted. This treatment resulted in complete dissolution of the thrombi.
Cardiac Thrombosis as a Manifestation of Behçet Syndrome
louali, Fedoua El; Tamdy, Asmae; Soufiani, Aida; Oukerraj, Latifa; Omari, Driss; Bounjoum, Fadwa; Mekouar, Fadwa; Tazi-Mezalek, Zoubida; Bouhouch, Rachida; Zarzur, Jamila; Cherti, Mohamed
2010-01-01
Herein, we report 3 cases of Behçet syndrome that were accompanied by intracardiac thrombus. The 1st patient was a 30-year-old man who presented with dyspnea; a right atrial thrombus was identified upon transthoracic echocardiography. The 2nd patient was a 52-year-old man who was admitted for dyspnea; transthoracic echocardiography revealed an echogenic mass in the right ventricle. The 3rd patient was a 23-year-old man who was hospitalized for hemoptysis; the diagnosis of pulmonary embolism was made, and right ventricular thrombosis was found. Because these patients had no hemodynamic compromise, medical management consisting of immunosuppressive and anticoagulative therapy was adopted. This treatment resulted in complete dissolution of the thrombi. PMID:20978571
Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system
NASA Technical Reports Server (NTRS)
Popp, R. L.; Brown, O. R.; Harrison, D. C.
1975-01-01
An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.
Alternative Etiologies for Stroke In Sickle Cell Anemia
Dowling, Michael Morgan; Quinn, Charles T.; Rogers, Zora R.; Journeycake, Janna M.
2009-01-01
Stroke is common in children with sickle cell anemia but is rarely attributed to the traditional causes of stroke identified in other children. We report an 11 year-old girl with sickle cell anemia who presented with severe headache and was found to have recurrent bilateral multifocal strokes in a cardioembolic pattern. Evaluation revealed the presence of a patent foramen ovale, antiphospholipid antibodies, and elevations in factor VIII and lipoprotein a. Sickle cell anemia is itself a hypercoaguable state with potential for increased right heart pressures, both of which predispose to paradoxical embolization via right-to-left intracardiac shunting of emboli causing stroke. This case suggests that the more traditional etiologies for pediatric stroke may also cause stroke in children with sickle cell anemia. PMID:19589461
Singh, M. P.; Bentall, H. H.; Oakley, C. M.
1970-01-01
Successful surgical correction of the complex anomaly of interruption of the aortic arch and intracardiac ventricular septal defect is reported. The patient was a boy 5 years old when he first came under treatment. The total correction was performed in two stages. At the first operation, at the age of 7 years, continuity of the aortic arch was achieved by insertion of a Teflon graft, employing left heart bypass. The ventricular septal defect was closed at the age of 13 years on total cardiopulmonary bypass. Two and half years after the total correction the boy is alive and well. The difficulties in diagnosing the condition are discussed. The role of left heart bypass is emphasized. Images PMID:5489187
Robotics in invasive cardiac electrophysiology.
Shurrab, Mohammed; Schilling, Richard; Gang, Eli; Khan, Ejaz M; Crystal, Eugene
2014-07-01
Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation system (Hansen Medical Inc., Mountain View, CA) have an established platform with at least 10 years of clinical studies looking at their efficacy and safety. AMIGO Remote Catheter System (Catheter Robotics, Inc., Mount Olive, NJ) and Catheter Guidance Control and Imaging (Magnetecs, Inglewood, CA) are in the earlier phases of implementations with ongoing feasibility and some limited clinical studies. This review discusses the advantages and limitations related to each existing system and highlights the ideal futuristic robotic system that may include the most promising features of the current ones.
Hamatani, Yasuhiro; Amaki, Makoto; Kanzaki, Hideaki; Yamashita, Kizuku; Nakashima, Yasuteru; Shibata, Atsushi; Okada, Atsushi; Takahama, Hiroyuki; Hasegawa, Takuya; Shimahara, Yusuke; Sugano, Yasuo; Fujita, Tomoyuki; Shiraishi, Isao; Yasuda, Satoshi; Kobayashi, Junjiro
2017-01-01
Abstract Both surgical myectomy and percutaneous transluminal septal myocardial ablation are effective treatments for drug‐refractory symptomatic hypertrophic obstructive cardiomyopathy (HOCM). However, in some cases, it is not easy to elucidate the abnormal structure of left ventricular outflow obstruction to adopt these treatments. Here, we presented a young female patient with drug‐refractory symptomatic HOCM. In this case, contrast‐enhanced computed tomography enabled us to assess the suitability of percutaneous transluminal septal myocardial ablation. By creating three‐dimensional printed models using computed tomography data, we could also visualize intracardiac structure and simulate the surgical procedure. A multimodality assessment strategy is useful for evaluating patients complicated with drug‐refractory symptomatic HOCM. PMID:29154429
Connexin43 Gene Transfer Reduces Ventricular Tachycardia Susceptibility After Myocardial Infarction
Greener, Ian D.; Sasano, Tetsuo; Wan, Xiaoping; Igarashi, Tomonori; Strom, Maria; Rosenbaum, David S.; Donahue, J. Kevin
2012-01-01
Objectives The aim of this study was to evaluate the links between connexin43 (Cx43) expression, myocardial conduction velocity, and ventricular tachycardia in a model of healed myocardial infarction. Background Post-infarction ventricular arrhythmias frequently cause sudden death. Impaired myocardial conduction has previously been linked to ventricular arrhythmias. Altered connexin expression is a potential source of conduction slowing identified in healed scar border tissues. The functional effect of increasing border-zone Cx43 has not been previously evaluated. Methods Twenty-five Yorkshire pigs underwent anterior infarction by transient left anterior descending coronary artery occlusion, followed by weekly testing for arrhythmia inducibility. Twenty animals with reproducibly inducible sustained monomorphic ventricular tachycardia were randomized 2:1:1 to receive AdCx43, Adβgal, or no gene transfer. One week later, animals underwent follow-up electrophysiologic study and tissue assessment for several functional and molecular measures. Results Animals receiving AdCx43 had less electrogram fractionation and faster conduction velocity in the anterior-septal border zone. Only 40% of AdCx43 animals remained inducible for ventricular tachycardia, while 100% of controls were inducible after gene transfer. AdCx43 animals had 2-fold higher Cx43 protein levels in the anterior-septal infarct border, with similar percents of phosphorylated and intercalated disk-localized Cx43 compared with controls. Conclusions These data mechanistically link Cx43 expression to slow conduction and arrhythmia susceptibility in the healed scar border zone. Targeted manipulation of Cx43 levels improved conduction velocity and reduced ventricular tachycardia susceptibility. Cx43 gene transfer represents a novel treatment strategy for post-infarction arrhythmias. PMID:22883636
NASA Astrophysics Data System (ADS)
Gan, Yu; Tsay, David; Amir, Syed B.; Marboe, Charles C.; Hendon, Christine P.
2016-03-01
Remodeling of the myocardium is associated with increased risk of arrhythmia and heart failure. Our objective is to automatically identify regions of fibrotic myocardium, dense collagen, and adipose tissue, which can serve as a way to guide radiofrequency ablation therapy or endomyocardial biopsies. Using computer vision and machine learning, we present an automated algorithm to classify tissue compositions from cardiac optical coherence tomography (OCT) images. Three dimensional OCT volumes were obtained from 15 human hearts ex vivo within 48 hours of donor death (source, NDRI). We first segmented B-scans using a graph searching method. We estimated the boundary of each region by minimizing a cost function, which consisted of intensity, gradient, and contour smoothness. Then, features, including texture analysis, optical properties, and statistics of high moments, were extracted. We used a statistical model, relevance vector machine, and trained this model with abovementioned features to classify tissue compositions. To validate our method, we applied our algorithm to 77 volumes. The datasets for validation were manually segmented and classified by two investigators who were blind to our algorithm results and identified the tissues based on trichrome histology and pathology. The difference between automated and manual segmentation was 51.78 +/- 50.96 μm. Experiments showed that the attenuation coefficients of dense collagen were significantly different from other tissue types (P < 0.05, ANOVA). Importantly, myocardial fibrosis tissues were different from normal myocardium in entropy and kurtosis. The tissue types were classified with an accuracy of 84%. The results show good agreements with histology.
Long-term biatrial recordings in post-operative atrial fibrillation.
Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F
2010-01-01
Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.
Messier, Erik
2016-08-01
A Multichannel Systems (MCS) microelectrode array data acquisition (DAQ) unit is used to collect multichannel electrograms (EGM) from a Langendorff perfused rabbit heart system to study sudden cardiac death (SCD). MCS provides software through which data being processed by the DAQ unit can be displayed and saved, but this software's combined utility with MATLAB is not very effective. MCSs software stores recorded EGM data in a MathCad (MCD) format, which is then converted to a text file format. These text files are very large, and it is therefore very time consuming to import the EGM data into MATLAB for real-time analysis. Therefore, customized MATLAB software was developed to control the acquisition of data from the MCS DAQ unit, and provide specific laboratory accommodations for this study of SCD. The developed DAQ unit control software will be able to accurately: provide real time display of EGM signals; record and save EGM signals in MATLAB in a desired format; and produce real time analysis of the EGM signals; all through an intuitive GUI.
Koneru, Jayanthi N; Swerdlow, Charles D; Ploux, Sylvain; Sharma, Parikshit S; Kaszala, Karoly; Tan, Alex Y; Huizar, Jose F; Vijayaraman, Pugazhendi; Kenigsberg, David; Ellenbogen, Kenneth A
2017-02-01
Implantable cardioverter defibrillators (ICDs) must establish a balance between delivering appropriate shocks for ventricular tachyarrhythmias and withholding inappropriate shocks for lead-related oversensing ("noise"). To improve the specificity of ICD therapy, manufacturers have developed proprietary algorithms that detect lead noise. The SecureSense TM RV Lead Noise discrimination (St. Jude Medical, St. Paul, MN, USA) algorithm is designed to differentiate oversensing due to lead failure from ventricular tachyarrhythmias and withhold therapies in the presence of sustained lead-related oversensing. We report 5 patients in whom appropriate ICD therapy was withheld due to the operation of the SecureSense algorithm and explain the mechanism for inhibition of therapy in each case. Limitations of algorithms designed to increase ICD therapy specificity, especially for the SecureSense algorithm, are analyzed. The SecureSense algorithm can withhold appropriate therapies for ventricular arrhythmias due to design and programming limitations. Electrophysiologists should have a thorough understanding of the SecureSense algorithm before routinely programming it and understand the implications for ventricular arrhythmia misclassification. © 2016 Wiley Periodicals, Inc.
Magnetic Resonance Imaging Evaluation of Cardiac Masses
Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André
2013-01-01
Background Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. Objective To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Methods Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Results Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). Conclusion CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility. PMID:23887734
Video-assisted thoracic surgical procedures in children.
Decampli, William M.
1998-01-01
The general principles and current applications of pediatric video-assisted cardiothoracic surgery (PVACTS) are reviewed. The purpose of PVACTS is to improve surgical quality and precision in selected operations. In the 1990s PVACTS has expanded to include the management of a variety of pulmonary, mediastinal, and cardiac lesions. Currently, PVACTS is carried out using a video camera connected to a low-profile scope and a specialized set of surgical instruments. PVACTS is an accepted modality for the diagnosis (by biopsy) of pleuropulmonary and mediastinal disease, and the treatment of pediatric empyema, spontaneous pneumothorax, and mediastinal cysts. Diaphragmatic plication, repair of chylous leak, and ligation of collateral vessels have all been done using PVACTS. PVACTS patent ductus arteriosus (PDA) ligation and vascular ring repair are being successfully carried out in several institutions. The technique at The Children's Hospital of Philadelphia is described. Indications and techniques for PVACTS lobectomy and pneumonectomy are less well established. Suggested anecdotal methods are described. Cardioscopy carries the hope of improving intracardiac repair, and has been applied to several lesions. The future of PVACTS depends on the surgeon's willingness to master it, industry's willingness to customize instruments for pediatric use, and developments in the fields of virtual imaging and augmented reality. Copyright 1998 by W.B. Saunders Company
Volumetric Real-Time Imaging Using a CMUT Ring Array
Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N.; O’Donnell, Matthew; Sahn, David J.; Khuri-Yakub, Butrus T.
2012-01-01
A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device. This paper presents simulated and experimental imaging results for the described CMUT ring array. Three different imaging methods—flash, classic phased array (CPA), and synthetic phased array (SPA)—were used in the study. For SPA imaging, two techniques to improve the image quality—Hadamard coding and aperture weighting—were also applied. The results show that SPA with Hadamard coding and aperture weighting is a good option for ring-array imaging. Compared with CPA, it achieves better image resolution and comparable signal-to-noise ratio at a much faster image acquisition rate. Using this method, a fast frame rate of up to 463 volumes per second is achievable if limited only by the ultrasound time of flight; with the described system we reconstructed three cross-sectional images in real-time at 10 frames per second, which was limited by the computation time in synthetic beamforming. PMID:22718870
Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.
Long, K J; Bonagura, J D; Darke, P G
1992-05-01
Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.
Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin
2003-12-25
In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged MAPD of all the three layers of the myocardium (P<0.05) with the character that mid-layer MAPD was the longest and subepicardial MAPD was the shortest following subendocardial MAPD. At the same time, TDR prolonged from 26.75 ms at RV-Endo pacing to 37.54 ms at BiV pacing and to 47.16 ms at LV-Epi pacing (P<0.001). Meanwhile in surface ECG, BiV and LV-Epi pacing resulted in a longer Tp-Te) interval compared with RV-Endo pacing (P<0.01), without parallel QT interval prolongation. Furthermore, all the DCM-CHF model dogs showed manifestations of congestive heart failure and enlargement of left ventricles. Based on the lengthening of mid-layer MAPD from 257.35 ms to 276.30 ms (P<0.0001) and increase of TDR from 27.58 ms to 33.80 ms (P equals;0.002) in DCM-CHF model due to the structural disorders of myocardium compared with the normal dog, LV-Epi and BiV pacing also led to the effect of prolonging MAPD of three layers of the myocardium and enlarging TDR. From these results we make the conclusions that prolongation of MAPD of subendocardial, subepicardial and mid-layer myocardium and increase in TDR during pacing participating of LV (LV-Epi, BiV) may contribute to the formation of unidirectional block and reentry, which play roles or at least are the high risk factors in the development of malignant ventricular arrhythmia, especially in case of structural disorders of myocardium. These findings must be considered seriously when ventricular resynchronization therapy is performed to congestive heart failure patients.
Carbon dioxide field flooding: a retrospective study.
Frados, A
2001-05-01
The carbon dioxide surgical field flooding technique has long been tried with varying degrees of success. A recent revival of the technique that began over 40 years ago in cardiac surgery, has brought promise as well as improved results attributable to improved technology. Studies at JFK Medical Center have been very successful using the carbon dioxide surgical field-flooding technique. Establishing new guidelines will assist other institutions in attempting this "old" technique with renewed success. Modern, more efficient equipment make use of carbon dioxide to displace intracardiac gases a safe procedure. The carbon dioxide field-flooding technique is safer, easier, and more efficacious than traditional de-airing techniques. This study shows that a long-standing procedure is valuable by observing the results, and, retrospectively evaluating stroke rates among cardiac valve cases at the hospital.
Protective effect of pulmonary hypertension against right-sided tamponade in pericardial effusion.
Khan, M Usman; Khouzam, Rami N
2015-01-01
Patients with pericardial effusion are susceptible to cardiac tamponade. A compressing circumferential pericardial effusion typically results in an equalization of intracardiac and pericardial pressure during diastole and a progressive collapse of the right atrium and ventricle. Pulmonary hypertension that increases the afterload of the right ventricle may result in elevated pressures initially in the right ventricle and subsequently in the right atrium. This may lead to right ventricular hypertrophy and a pathologic structural and functional remodeling of both right heart chambers. Conversely, elevated pressures within the right heart chambers caused by longstanding pulmonary hypertension may resist and protect against tamponade of these chambers in the setting of a coexisting pericardial effusion. In such cases, a sudden reduction in pulmonary arterial pressures may result in tamponade of the right heart chambers.
Limited access atrial septal defect closure and the evolution of minimally invasive surgery.
Izzat, M B; Yim, A P; El-Zufari, M H
1998-04-01
While minimizing the "invasiveness" in general surgery has been equated with minimizing "access", what constitutes minimally invasive intra-cardiac surgery remains controversial. Many surgeons doubt the benefits of minimizing access when the need for cardiopulmonary bypass cannot be waived. Recognizing that median sternotomy itself does entail significant morbidity, we investigated the value of alternative approaches to median sternotomy using atrial septal defect closure as our investigative model. We believe that some, but not all minimal access approaches are associated with reduced postoperative morbidity and enhanced recovery. Our current strategy is to use a mini-sternotomy approach in adult patients, whereas conventional median sternotomy remains our standard approach in the pediatric population. Considerable clinical experiences coupled with documented clinical benefits are fundamental before a certain approach is adopted in routine practice.
[Rhythm disorders and cardiac crypto-malformations].
Davy, J M; Raczka, F; Cung, T T; Combes, N; Bortone, A; Gaty, D
2005-12-01
Faced with a cardiac arrhythmia occuring in an apparently healthy heart, it is necessary to perform an anatomical investigation to detect any unsuspected anomalies. Congenital cardiopathy must certainly be excluded, as this is often responsible for rhythm disorders and/or cardiac conduction defects. Similarly, any acquired conditions, cardiomyopathy, or cardiac tumour must be sought. However, the possibility should always be considered of a minimal congenital malformation, which could be repsonsible for: any type of cardiac arrhythmia: rhythm disorder or conduction defect at the atrial, junctional or ventricular level, with a benign or serious prognosis. Unexpected therapeutic difficulties during radiofrequency ablation procedures or at implantation of pacemakers or defibrillators. Together with rhythm studies, the investigation of choice is high quality imaging, either the classic left or right angiography or the more modern cardiac CT or intracardiac mapping.
Noji, S; Kitamura, N; Yamaguchi, A; Otaki, M; Miki, T; Tamura, H
1991-08-01
We present a surgical case of 41-year-old woman with Scimitar syndrome. Preoperative catheterization showed azygos connection and L-R shunt ratio of 45% without intracardiac malformations. To our knowledge, this combination has not been previously reported. At operation the right single pulmonary vein was found and drained into the inferior vena cava below the diaphragm. Because of counter clockwise rotation of the heart the distance of the scimitar vein and the left atrium was too long for direct anastomosis, a polytetrafluoroethylene tube (10 mm in diameter) was utilized for an extracardiac conduit using cardiopulmonary bypass. Postoperative course was uneventful. We conclude that this technique is effective for this syndrome with a large amount of L-R shunt and a sufficient patency is expected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ch'ng, Julie; Chan, William; Lee, Paul
2003-06-01
Staphylococcus aureus is a leading cause of septicaemia and infective endocarditis. The overall incidence of staphylococcal bacteraemia is increasing, contributing to 16% of all hospital-acquired bacteraemias. The use of cardiac pacemakers has revolutionized the management of rhythm disturbances, yet this has also resulted in a group of patients at risk of pacemaker lead endocarditis and seeding in the range of 1% to 7%. We describe a 26-year-old man with transposition of the great arteries who had a pacemaker implanted and presented with S. aureus septicaemia 2 years postpacemaker implantation and went on to develop pacemaker lead endocarditis. This report illustratesmore » the risk of endocarditis in the population with congenital heart disease and an intracardiac device.« less
Opotowsky, Alexander R; Landzberg, Michael J; Kimmel, Stephen E; Webb, Gary D
2009-05-01
Percutaneous closure of patent foramen ovale/atrial septal defect (PFO/ASD) is an increasingly common procedure perceived as having minimal risk. There are no population-based estimates of in-hospital adverse event rates of percutaneous PFO/ASD closure. We used nationally representative data from the 2001-2005 Nationwide Inpatient Sample to identify patients >or-=20 years old admitted to an acute care hospital with an International Classification of Diseases, Ninth Revision code designating percutaneous PFO/ASD closure on the first or second hospital day. Variables analyzed included age, sex, number of comorbidities, year, same-day use of intracardiac or other echocardiography, same-day left heart catheterization, hospital size and teaching status, PFO/ASD procedural volume, and coronary intervention volume. Outcomes of interest included length of stay, charges, and adverse events. The study included 2,555 (weighted to United States population: 12,544 +/- 1,987) PFO/ASD closure procedures. Mean age was 52.0 +/- 0.4 years, and 57.3% +/- 1.0% were women. Annual hospital volume averaged 40.8 +/- 7.7 procedures (range, 1-114). Overall, 8.2 +/- 0.8% of admissions involved an adverse event. Older patients and those with comorbidities were more likely to sustain adverse events. Use of intracardiac echocardiography was associated with fewer adverse events. The risk of adverse events was inversely proportional to annual hospital volume (odds ratio [OR] 0.91, 95% confidence interval [CI] 0.86-0.96, per 10 procedures), even after limiting the analysis to hospitals performing >or=10 procedures annually (OR 0.91, 95% CI 0.85-0.98). Adverse events were more frequent at hospitals in the lowest volume quintile as compared with the highest volume quintile (13.3% vs 5.4%, OR 2.42, 95% CI 1.55-3.78). The risk of adverse events of percutaneous PFO/ASD closure is inversely correlated with hospital volume. This relationship applies even to hospitals meeting the current guidelines, performing >or=10 procedures annually.
Femnou, Armel N; Kuzmiak-Glancy, Sarah; Covian, Raul; Giles, Abigail V; Kay, Matthew W; Balaban, Robert S
2017-12-01
Absorbance spectroscopy of intrinsic cardiac chromophores provides nondestructive assessment of cytosolic oxygenation and mitochondria redox state. Isolated perfused heart spectroscopy is usually conducted by collecting reflected light from the heart surface, which represents a combination of surface scattering events and light that traversed portions of the myocardium. Reflectance spectroscopy with complex surface scattering effects in the beating heart leads to difficulty in quantitating chromophore absorbance. In this study, surface scattering was minimized and transmural path length optimized by placing a light source within the left ventricular chamber while monitoring transmurally transmitted light at the epicardial surface. The custom-designed intrachamber light catheter was a flexible coaxial cable (2.42-Fr) terminated with an encapsulated side-firing LED of 1.8 × 0.8 mm, altogether similar in size to a Millar pressure catheter. The LED catheter had minimal impact on aortic flow and heart rate in Langendorff perfusion and did not impact stability of the left ventricule of the working heart. Changes in transmural absorbance spectra were deconvoluted using a library of chromophore reference spectra to quantify the relative contribution of specific chromophores to the changes in measured absorbance. This broad-band spectral deconvolution approach eliminated errors that may result from simple dual-wavelength absorbance intensity. The myoglobin oxygenation level was only 82.2 ± 3.0%, whereas cytochrome c and cytochrome a + a 3 were 13.3 ± 1.4% and 12.6 ± 2.2% reduced, respectively, in the Langendorff-perfused heart. The intracardiac illumination strategy permits transmural optical absorbance spectroscopy in perfused hearts, which provides a noninvasive real-time monitor of cytosolic oxygenation and mitochondria redox state. NEW & NOTEWORTHY Here, a novel nondestructive real-time approach for monitoring intrinsic indicators of cardiac metabolism and oxygenation is described using a catheter-based transillumination of the left ventricular free wall together with complete spectral analysis of transmitted light. This approach is a significant improvement in the quality of cardiac optical absorbance spectroscopic metabolic analyses.
Feridooni, Tiam; Hotchkiss, Adam; Baguma-Nibasheka, Mark; Zhang, Feixiong; Allen, Brittney; Chinni, Sarita; Pasumarthi, Kishore B S
2017-05-01
β-Adrenergic receptors (β-ARs) and catecholamines are present in rodents as early as embryonic day (E)10.5. However, it is not known whether β-AR signaling plays any role in the proliferation and differentiation of ventricular cells in the embryonic heart. Here, we characterized expression profiles of β-AR subtypes and established dose-response curves for the nonselective β-AR agonist isoproterenol (ISO) in the developing mouse ventricular cells. Furthermore, we investigated the effects of ISO on cell cycle activity and differentiation of cultured E11.5 ventricular cells. ISO treatment significantly reduced tritiated thymidine incorporation and cell proliferation rates in both cardiac progenitor cell and cardiomyocyte populations. The ISO-mediated effects on DNA synthesis could be abolished by cotreatment of E11.5 cultures with either metoprolol (a β 1 -AR antagonist) or ICI-118,551 (a β 2 -AR antagonist). In contrast, ISO-mediated effects on cell proliferation could be abolished only by metoprolol. Furthermore, ISO treatment significantly increased the percentage of differentiated cardiomyocytes compared with that in control cultures. Additional experiments revealed that β-AR stimulation leads to downregulation of Erk and Akt phosphorylation followed by significant decreases in cyclin D1 and cyclin-dependent kinase 4 levels in E11.5 ventricular cells. Consistent with in vitro results, we found that chronic stimulation of recipient mice with ISO after intracardiac cell transplantation significantly decreased graft size, whereas metoprolol protected grafts from the inhibitory effects of systemic catecholamines. Collectively, these results underscore the effects of β-AR signaling in cardiac development as well as graft expansion after cell transplantation. NEW & NOTEWORTHY β-Adrenergic receptor (β-AR) stimulation can decrease the proliferation of embryonic ventricular cells in vitro and reduce the graft size after intracardiac cell transplantation. In contrast, β 1 -AR antagonists can abrogate the antiproliferative effects mediated by β-AR stimulation and increase graft size. These results highlight potential interactions between adrenergic drugs and cell transplantation. Copyright © 2017 the American Physiological Society.
Gerelli, Sébastien; van Steenberghe, Mathieu; Murtuza, Bari; Bojan, Mirela; Harding, Ekoué Diana; Bonnet, Damien; Vouhé, Pascal R; Raisky, Olivier
2014-02-01
Right ventricle to pulmonary artery connection (RVPA connection) without prosthetic material has been our ideal strategy to palliate pulmonary atresia with ventricular septal defect (VSD) or severe tetralogy of Fallot for the last decade. We speculate that RVPA connection ensures adequate postoperative haemodynamics for symptomatic neonates and promotes pulmonary artery rehabilitation. The present study was undertaken to assess the outcome of this strategy. Between 2000 and 2010, among 107 patients who benefited from an RVPA connection, 57 were neonates. Forty-eight of these underwent autologous tissue reconstruction, 5 using left atrial appendage. Median weight was 2.9 kg (range 1.8-4.4). Median Nakata index was 100 mm2/m2 (range 17-185 mm2/m2); 12% had major aortopulmonary collaterals. All patients were reviewed retrospectively. End-points were death or complete repair; reintervention for restrictive pulmonary blood flow was considered as failure. At follow-up, we evaluated reintervention after complete repair, and quality of life. There were 2 early deaths (RV hypoplasia and RV failure) and 3 late sudden deaths (range 3-6 months). Pulmonary blood flow required to be increased in 8 patients: 4 underwent shunt after a median delay of 1 month; RVPA connection enlargement was needed in 3; 1 patient had percutaneous angioplasty. Finally, 47 patients (81%) had a complete repair, of which 70% were performed without prosthetic material at a median age of 7 months (range 2-53), with a median Nakata index of 221 mm2/m2 (range 102-891). One patient died early and 1 was a failure with opening of the VSD after intracardiac repair. At last follow-up, 4 patients were still awaiting repair, with 1 late death and 5 who had required reintervention after intracardiac repair; there were 3 conduit replacements and 2 balloon dilatation patch enlargements. The neonatal RVPA connection approach (i) provides an acceptable survival rate with a satisfactory haemodynamic adaptation, (ii) facilitates rehabilitation of PAs and (iii) avoids the use of prosthetic graft at correction.
Frangieh, Antonio H; Alibegovic, Jasmina; Templin, Christian; Gaemperli, Oliver; Obeid, Slayman; Manka, Robert; Holy, Erik W; Maier, Willibald; Lüscher, Thomas F; Binder, Ronald K
2017-08-01
Left atrial appendage occlusion (LAAO) is mostly performed by transesophageal echocardiography (TEE) guidance. Intracardiac echocardiography (ICE) may be an alternative imaging modality for LAAO that precludes the need for general anesthesia or sedation. All consecutive single center, single operator LAAO candidates were analyzed. Baseline clinical and procedural characteristics and in-hospital outcomes were compared between patients in whom a Watchman was implanted with ICE vs. TEE guidance. In 76 consecutive patients the Watchman device was deployed under ICE in 32 patients (42%) and under TEE guidance in 44 patients (58%). Baseline characteristics were comparable between groups, except that patients in the TEE group were older (81 [75-85] years vs. 75 [68-80] years, P = 0.007). Total injected contrast media as well as fluoroscopy time were comparable between groups (90 ml [54-140] vs. 85 ml [80-110], P = 0.86 and 7.9 min [6.4-15.5] vs. 9.8 min [7.0-13.2], P = 0.51, for TEE vs. ICE, respectively). However, time from femoral venous puncture to transseptal puncture and to closure was longer in the ICE group (14 min [7.3-20] vs. 6 min [3.3-11], P = 0.007 and 48 min [40-60] vs. 34.5 min [27-44], P = 0.003, respectively). In the TEE group one patient suffered esophageal erosion with bleeding, which was managed conservatively and one non-LAAO related in-hospital mortality occurred in an 88-year-old patient. Device implantation success rate was 100% in both groups. No device embolization, no significant peri-device leak, no tamponade, no stroke, and no access site bleeding occurred in any patient. Total hospital stay for stand-alone LAAO was comparable between groups (2 days [2-2] vs. 2 days [2-3.3], P = 0.17, in ICE vs. TEE, respectively). ICE guidance for LAAO with the Watchman device is feasible and comparable to TEE and may become the preferred imaging modality for LAAO. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Mukhopadhyay, Keya De; Bandyopadhyay, Abhik; Chang, Ting-Tung A; Elkahloun, Abdel G; Cornell, John E; Yang, Junhua; Goins, Beth A; Yeh, I-Tien; Sun, Lu-Zhe
2011-01-01
The origin and the contribution of breast tumor heterogeneity to its progression are not clear. We investigated the effect of a growing orthotopic tumor formed by an aggressive estrogen receptor (ER)-negative breast cancer cell line on the metastatic potential of a less aggressive ER-positive breast cancer cell line for the elucidation of how the presence of heterogeneous cancer cells might affect each other's metastatic behavior. ER positive ZR-75-1/GFP/puro cells, resistant to puromycin and non-tumorigenic/non-metastatic without exogenous estrogen supplementation, were injected intracardiacally into mice bearing growing orthotopic tumors, formed by ER negative MDA-MB-231/GFP/Neo cells resistant to G418. A variant cell line B6, containing both estrogen-dependent and -independent cells, were isolated from GFP expressing cells in the bone marrow and re-inoculated in nude mice to generate an estrogen-independent cell line B6TC. The presence of ER negative orthotopic tumors resulted in bone metastasis of ZR-75-1 without estrogen supplementation. The newly established B6TC cell line was tumorigenic without estrogen supplementation and resistant to both puromycin and G418 suggesting its origin from the fusion of MDA-MB-231/GFP/Neo and ZR-75-1/GFP/puro in the mouse bone marrow. Compared to parental cells, B6TC cells were more metastatic to lung and bone after intracardiac inoculation. More significantly, B6TC mice also developed brain metastasis, which was not observed in the MDA-MB-231/GFP/Neo cell-inoculated mice. Low expression of ERα and CD24, and high expression of EMT-related markers such as Vimentin, CXCR4, and Integrin-β1 along with high CD44 and ALDH expression indicated stem cell-like characteristics of B6TC. Gene microarray analysis demonstrated a significantly different gene expression profile of B6TC in comparison to those of parental cell lines. Spontaneous generation of the novel hybrid cell line B6TC, in a metastatic site with stem cell-like properties and propensity to metastasize to brain, suggest that cell fusion can contribute to tumor heterogeneity.
Zhang, Dongze; Tu, Huiyin; Cao, Liang; Zheng, Hong; Muelleman, Robert L; Wadman, Michael C; Li, Yu-Long
2018-01-15
Attenuated cardiac vagal activity is associated with ventricular arrhythmogenesis and related mortality in patients with chronic heart failure. Our recent study has shown that expression of N-type Ca 2+ channel α-subunits (Ca v 2.2-α) and N-type Ca 2+ currents are reduced in intracardiac ganglion neurons from rats with chronic heart failure. Rat intracardiac ganglia are divided into the atrioventricular ganglion (AVG) and sinoatrial ganglion. Ventricular myocardium receives projection of neuronal terminals only from the AVG. In this study we tested whether a decrease in N-type Ca 2+ channels in AVG neurons contributes to ventricular arrhythmogenesis. Lentiviral Ca v 2.2-α shRNA (2 μL, 2×10 7 pfu/mL) or scrambled shRNA was in vivo transfected into rat AVG neurons. Nontransfected sham rats served as controls. Using real-time single-cell polymerase chain reaction and reverse-phase protein array, we found that in vivo transfection of Ca v 2.2-α shRNA decreased expression of Ca v 2.2-α mRNA and protein in rat AVG neurons. Whole-cell patch-clamp data showed that Ca v 2.2-α shRNA reduced N-type Ca 2+ currents and cell excitability in AVG neurons. The data from telemetry electrocardiographic recording demonstrated that 83% (5 out of 6) of conscious rats with Ca v 2.2-α shRNA transfection had premature ventricular contractions ( P <0.05 versus 0% of nontransfected sham rats or scrambled shRNA-transfected rats). Additionally, an index of susceptibility to ventricular arrhythmias, inducibility of ventricular arrhythmias evoked by programmed electrical stimulation, was higher in rats with Ca v 2.2-α shRNA transfection compared with nontransfected sham rats and scrambled shRNA-transfected rats. A decrease in N-type Ca 2+ channels in AVG neurons attenuates vagal control of ventricular myocardium, thereby initiating ventricular arrhythmias. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
A Leadless Intracardiac Transcatheter Pacing System.
Reynolds, Dwight; Duray, Gabor Z; Omar, Razali; Soejima, Kyoko; Neuzil, Petr; Zhang, Shu; Narasimhan, Calambur; Steinwender, Clemens; Brugada, Josep; Lloyd, Michael; Roberts, Paul R; Sagi, Venkata; Hummel, John; Bongiorni, Maria Grazia; Knops, Reinoud E; Ellis, Christopher R; Gornick, Charles C; Bernabei, Matthew A; Laager, Verla; Stromberg, Kurt; Williams, Eric R; Hudnall, J Harrison; Ritter, Philippe
2016-02-11
A leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead. In a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies. The device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001). In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).
Kanski, Mikael; Arvidsson, Per M; Töger, Johannes; Borgquist, Rasmus; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan
2015-12-20
Measurement of intracardiac kinetic energy (KE) provides new insights into cardiac hemodynamics and may improve assessment and understanding of heart failure. We therefore aimed to investigate left ventricular (LV) KE time curves in patients with heart failure and in controls. Patients with heart failure (n = 29, NYHA class I-IV) and controls (n = 12) underwent cardiovascular magnetic resonance (CMR) including 4D flow. The vortex-ring boundary was computed using Lagrangian coherent structures. The LV endocardium and vortex-ring were manually delineated and KE was calculated as ½mv(2) of the blood within the whole LV and the vortex ring, respectively. The systolic average KE was higher in patients compared to controls (2.2 ± 1.4 mJ vs 1.6 ± 0.6 mJ, p = 0.048), but lower when indexing to EDV (6.3 ± 2.2 μJ/ml vs 8.0 ± 2.1 μJ/ml, p = 0.025). No difference was seen in diastolic average KE (3.2 ± 2.3 mJ vs 2.0 ± 0.8 mJ, p = 0.13) even when indexing to EDV (9.0 ± 4.4 μJ/ml vs 10.2 ± 3.3 μJ/ml, p = 0.41). In patients, a smaller fraction of diastolic average KE was observed inside the vortex ring compared to controls (72 ± 6% vs 54 ± 9%, p < 0.0001). Three distinctive KE time curves were seen in patients which were markedly different from findings in controls, and with a moderate agreement between KE time curve patterns and degree of diastolic dysfunction (Cohen's kappa = 0.49), but unrelated to NYHA classification (p = 0.12), or 6-minute walk test (p = 0.72). Patients with heart failure exhibit higher systolic average KE compared to controls, suggesting altered intracardiac blood flow. The different KE time curves seen in patients may represent a conceptually new approach for heart failure classification.
Mandel, Yael; Weissman, Amir; Schick, Revital; Barad, Lili; Novak, Atara; Meiry, Gideon; Goldberg, Stanislav; Lorber, Avraham; Rosen, Michael R; Itskovitz-Eldor, Joseph; Binah, Ofer
2012-02-21
The sinoatrial node is the main impulse-generating tissue in the heart. Atrioventricular conduction block and arrhythmias caused by sinoatrial node dysfunction are clinically important and generally treated with electronic pacemakers. Although an excellent solution, electronic pacemakers incorporate limitations that have stimulated research on biological pacing. To assess the suitability of potential biological pacemakers, we tested the hypothesis that the spontaneous electric activity of human embryonic stem cell-derived cardiomyocytes (hESC-CMs) and induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) exhibit beat rate variability and power-law behavior comparable to those of human sinoatrial node. We recorded extracellular electrograms from hESC-CMs and iPSC-CMs under stable conditions for up to 15 days. The beat rate time series of the spontaneous activity were examined in terms of their power spectral density and additional methods derived from nonlinear dynamics. The major findings were that the mean beat rate of hESC-CMs and iPSC-CMs was stable throughout the 15-day follow-up period and was similar in both cell types, that hESC-CMs and iPSC-CMs exhibited intrinsic beat rate variability and fractal behavior, and that isoproterenol increased and carbamylcholine decreased the beating rate in both hESC-CMs and iPSC-CMs. This is the first study demonstrating that hESC-CMs and iPSC-CMs exhibit beat rate variability and power-law behavior as in humans, thus supporting the potential capability of these cell sources to serve as biological pacemakers. Our ability to generate sinoatrial-compatible spontaneous cardiomyocytes from the patient's own hair (via keratinocyte-derived iPSCs), thus eliminating the critical need for immunosuppression, renders these myocytes an attractive cell source as biological pacemakers.
Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam
2016-01-01
Background Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Methods Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. Results 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Conclusion Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF. PMID:26909492
Madhavan, Malini; Venkatachalam, K. L.; Swale, Matthew J.; DeSimone, Christopher V.; Gard, Joseph J.; Johnson, Susan B.; Suddendorf, Scott H.; Mikell, Susan B.; Ladewig, Dorothy J.; Nosbush, Toni Grabinger; Danielsen, Andrew J.; Knudson, Mark; Asirvatham, Samuel J.
2016-01-01
Background Endocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters. Methods Phase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n=10). Phase 2: Percutaneous epicardial ablation of GP was done in 6 dogs using the most efficacious modality identified in phase 1 using 2 novel catheters. Results Phase 1: DC in varying doses [blocking (7 -12μA), electroporation (300-500μA), ablation (3000- 7500μA)], radiofrequency ablation (25–50 W), ultrasound (1.5MHz), and alcohol (2-5ml) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5 and 5/7 GP sites. DC (500–5000μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation (VF) during DC ablation at 5000 μA. Programmed stimulation induced AF in 6 dogs pre-ablation and no atrial arrhythmia in 3, flutter in 1 and AF in 1 post-ablation. Heart rate, blood pressure, effective atrial refractory period and local atrial electrogram amplitude did not change significantly post-ablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium. Conclusion Percutaneous epicardial ablation of GP using direct current and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of atrial fibrillation in order to minimize additional atrial myocardial ablation. PMID:26854009
Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O’Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter
2014-01-01
Background Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Methods and Results Activation recovery intervals (ARI) measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady state pacing while subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Haemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (p=0.001). APD decreased during the stressful parts of the film clip, eg for global RV ARI at end of film clip 193.8ms (SD 14) vs 198.0ms (SD13) during the matched breathing control (end film LV 199.8ms (SD16) vs control 201.6ms (SD15), p=0.004. Respiration rate increased during the stressful part of the film clip (by 2 breaths/minute), and was well matched in the respective control period without any haemodynamic or ARI changes. Conclusions Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular action potential duration in conscious humans. The effect of mental challenge on APD was not secondary to emotionally-induced altered respiration or heart rate. PMID:24833641
Tricuspid valve chordal rupture due to airbag injury and review of pathophysiological mechanisms.
Thekkudan, Joyce; Luckraz, Heyman; Ng, Alex; Norell, Mike
2012-09-01
Blunt trauma to the chest is associated with significant morbidity and mortality. The latter is usually due to an aortic transection, whereas the former is related to myocardial contusion, cardiac valve injury, coronary artery disruption and intracardiac shunts due to the formation of septal defects. The main mechanisms causing these injuries are due to the sudden deceleration force and compression within the chest cavity. Moreover, there is also the sudden increase in intravascular pressure due to a mechanical compression effect and a hormonal adrenergic surge during the event. We report a case of a tricuspid valve injury caused by the deployment of the airbag during a high-speed impact car accident and the subsequent damage to the tricuspid valve chordal mechanism. The patient's management and the pathophysiological mechanisms involved in the injury are reviewed.
Buchan, Iris; Covvey, H. Dominic; Rakowski, Harry
1985-01-01
A program has been developed for left ventricular (LV) border tracking on ultrasound images. For each frame, forty border points at equally-spaced angles around the LV center are found gradually during three passes. Pass 1 uses adaptive thresholding to find the most obvious border points. Pass 2 then uses an artificial intelligence technique of finding possible border path segments, associating a score with each, and, from paths with superior scores, obtaining more of the border points. Pass 3 closes any remaining gaps by interpolation. The program tracks the LV border quite well in spite of dropout and interference from intracardiac structures, except during end-systole. Multi-level passes provide a very useful structure for border tracking, with increasingly slow but more sophisticated algorithms possible at higher levels for use when earlier passes recognise failure.
Marchesi, Matteo; Battistini, Alessio; Pellegrinelli, Moira; Gentile, Guendalina; Zoja, Riccardo
2016-01-01
Fatal air embolism related to endoscopic retrograde cholangiopancreatography is a very rare phenomenon. The authors describe the case of a 51-year-old female patient who developed this mortal complication; a computed tomography (CT) examination was performed in articulo mortis by the physicians. Autopsy was unreliable because of bizarre post-mortem changes (reabsorption of intra-cardiac gas vs. conservation of intra-cranial gas) and a lack of strong diagnostic value of histological findings. The right diagnosis was possible thanks only to the CT examination that permitted the assumption of this possible cause of death before the autopsy and to prepare the necessary procedures to recognise and probe air embolism. This case exemplifies how early post-mortem imaging can be crucial to avoid a wrong diagnosis. © The Author(s) 2015.
Robotics in Cardiac Surgery: Past, Present, and Future
Bush, Bryan; Nifong, L. Wiley; Chitwood, W. Randolph
2013-01-01
Robotic cardiac operations evolved from minimally invasive operations and offer similar theoretical benefits, including less pain, shorter length of stay, improved cosmesis, and quicker return to preoperative level of functional activity. The additional benefits offered by robotic surgical systems include improved dexterity and degrees of freedom, tremor-free movements, ambidexterity, and the avoidance of the fulcrum effect that is intrinsic when using long-shaft endoscopic instruments. Also, optics and operative visualization are vastly improved compared with direct vision and traditional videoscopes. Robotic systems have been utilized successfully to perform complex mitral valve repairs, coronary revascularization, atrial fibrillation ablation, intracardiac tumor resections, atrial septal defect closures, and left ventricular lead implantation. The history and evolution of these procedures, as well as the present status and future directions of robotic cardiac surgery, are presented in this review. PMID:23908867
Bartoletti, Stefano; Santangeli, Pasquale; DI Biase, Luigi; Natale, Andrea
2013-01-01
Patients with mechanical "hardware" in the heart, such as those with mechanical cardiac valves or atrial septal closure devices, represent a population at high risk of developing AF. Catheter ablation of AF in these subjects might represent a challenge, due to the perceived higher risk of complications associated with the presence of intracardiac mechanical devices. Accordingly, such patients were excluded or poorly represented in major trials proving the benefit of catheter ablation for the rhythm-control of AF. However, recent evidence supports the concept that catheter ablation procedures might be equally effective in these patients, without a significant increase in the risk of procedural complications. This review will summarize the current state-of-the-art on catheter ablation of AF in patients with mechanical "hardware" in the heart.
Tang, Hong; Ruan, Chengjie; Qiu, Tianshuang; Park, Yongwan; Xiao, Shouzhong
2013-08-01
The relationships between the amplitude of the first heart sound (S1) and the rising rate of left ventricular pressure (LVP) concluded in previous studies were not consistent. Some researchers believed the relationship was positively linear; others stated the relationship was only positively correlated. To further investigate this relationship, this study simultaneously sampled the external phonocardiogram, electrocardiogram, and intracardiac pressure in the left ventricle in three anesthetized dogs, while invoking wide hemodynamic changes using various doses of epinephrine. The relationship between the maximum amplitude of S1 and the maximum rising rate of LVP and the relationship between the amplitude of dominant peaks/valleys and the corresponding rising rate of LVP were examined by linear, quadratic, cubic, and exponential models. The results showed that the relationships are best fit by nonlinear exponential models.
Tanimura, Kazuki; Miura, Yukiko; Ishii, Hisanari
2016-02-01
An 18-year-old female patinet with Ebstein anomaly underwent surgical repair of scoliosis under total intravenous anesthesia. In addtition to normal monitors, we used transesophageal echocardiography (TEE) and EV1000 (Edwards Lifesciences, Irvine, USA), which show stroke volume variation and stroke volume index simultaneously in a rectangular coordinates. TEE detected reversal of intracardiac shunt which caused SpO2 decrease during fixing screws at thoracic vertebrae, then manual ventilation with oxygen unproved SpO2. Because of a high venous pressure due to Ebstein anomaly, surgical bleeding seemed to be larger than usual. By using EV1000, volume status and cardiac contractility were estimated and adequate volume loading and inoptrope injection were performed to stabilize circulatory condition. The operation was completed without any cardiac and respiratory complications.
The role of flow in the morphodynamics of embryonic heart
NASA Astrophysics Data System (ADS)
Gharib, Morteza
2017-11-01
Nature has shown us that some hearts do not require valves to achieve unidirectional flow. In its earliest stages, the vertebrate heart consists of a primitive tube that drives blood through a simple vascular network nourishing tissues and other developing organ systems. We have shown that in the case of the embryonic zebrafish heart, an elastic wave resonance mechanism based on impedance mismatches at the boundaries of the heart tube is the likely mechanism responsible for the valveless pumping behavior. When functioning normally, mature heart valves prevent intracardiac retrograde blood flow; before valves develop there is considerable regurgitation, resulting in oscillatory flow between the atrium and ventricle. We show that reversing flows are particularly strong stimuli to endothelial cells and that heart valves form as a developmental response to oscillatory blood flow through the maturing heart.
Prenatal exposure to methyldopa leading to hypertensive crisis and cardiac failure in a neonate.
Su, Jennifer A; Tang, William; Rivero, Niurka; Bar-Cohen, Yaniv
2014-05-01
A 2-week-old infant with normal intracardiac anatomy presented to the emergency department in a hypertensive crisis with acute cardiac failure. Despite extensive evaluation, no underlying disease was found. The patient's hypertension and cardiac dysfunction resolved after 1 week of supportive care in the PICU, and she was discharged within 2 weeks of presentation. The patient's history revealed transplacental exposure to the α-adrenergic agonist methyldopa for 10 weeks before delivery. Her age at presentation and the self-limited nature of cardiac sequelae with complete resolution of cardiac dysfunction suggest withdrawal effects from this exposure. Whereas the rebound hypertensive effects of α-adrenergic agonists are well established in the adult population, this report shows an unusual adverse outcome of in utero exposure to methyldopa. Copyright © 2014 by the American Academy of Pediatrics.
Relating Venous Gas Emboli (VGE) Scores to Altitude Decompression Sickness (DCS) Symptoms
NASA Technical Reports Server (NTRS)
Pilmanis, A. A.; Kannan, N.; Krause, K. M.; Webb, J. T.
1999-01-01
Purpose. It is generally accepted that DCS symptoms are caused by gas bubbles in tissues. However, current technology of bubble detection only permits monitoring of circulating bubbles, primarily intracardiac. Since the majority of DCS symptoms appear to be caused by extravascular bubbles, it has been suggested that current bubble detection techniques target bubbles that are of importance in only a minority of DCS cases. The purpose of this study is to determine the relationships between measured VGE and DCS symptoms in human subjects exposed to altitude. Methods. The AFRL DCS Research Database contains records on 2044 subject-exposures to simulated altitudes in a hypobaric chamber. VGE monitoring was accomplished using Doppler/Echo Imaging techniques. The Spencer Scale was used to score the VGE. Reporting of DCS symptoms by the subject was the primary end-point of the exposures. Results: The Mantel- Haenzel test indicated a strong correlation between DCS and bubble grade (p-value =0.001). Conclusions. A positive correlation between increasing VGE scores and DCS symptoms, does not imply causatinn. If all non-zero VGE grades are considered, 45.9% of the cases had VGE, but no DCS symptoms. Conversely, almost 1 in 5 subject-exposures resulted in DCS with NO VGE detected. VGE scores are not . good predictors of altitude DCS symptoms and field use of bubble detection for DCS prevention is not supported by this study.
Kaseno, Kenichi; Hisazaki, Kaori; Nakamura, Kohki; Ikeda, Etsuko; Hasegawa, Kanae; Aoyama, Daisetsu; Shiomi, Yuichiro; Ikeda, Hiroyuki; Morishita, Tetsuji; Ishida, Kentaro; Amaya, Naoki; Uzui, Hiroyasu; Tada, Hiroshi
2018-04-14
Intracardiac echocardiographic (ICE) imaging might be useful for integrating three-dimensional computed tomographic (CT) images for left atrial (LA) catheter navigation during atrial fibrillation (AF) ablation. However, the optimal CT image integration method using ICE has not been established. This study included 52 AF patients who underwent successful circumferential pulmonary vein isolation (CPVI). In all patients, CT image integration was performed after the CPVI with the following two methods: (1) using ICE images of the LA derived from the right atrium and right ventricular outflow tract (RA-merge) and (2) using ICE images of the LA directly derived from the LA added to the image for the RA-merge (LA-merge). The accuracy of these two methods was assessed by the distances between the integrated CT image and ICE image (ICE-to-CT distance), and between the CT image and actual ablated sites for the CPVI (CT-to-ABL distance). The mean ICE-to-CT distance was comparable between the two methods (RA-merge = 1.6 ± 0.5 mm, LA-merge = 1.7 ± 0.4 mm; p = 0.33). However, the mean CT-to-ABL distance was shorter for the LA-merge (2.1 ± 0.6 mm) than RA-merge (2.5 ± 0.8 mm; p < 0.01). The LA, especially the left-sided PVs and LA roof, was more sharply delineated by direct LA imaging, and whereas the greatest CT-to-ABL distance was observed at the roof portion of the left superior PV (3.7 ± 2.8 mm) after the RA-merge, it improved to 2.6 ± 1.9 mm after the LA-merge (p < 0.01). Additional ICE images of the LA directly acquired from the LA might lead to a greater accuracy of the CT image integration for the CVPI.
Censi, F; Barbaro, V; Bartolini, P; Calcagnini, G; Michelucci, A; Gensini, G F; Cerutti, S
2000-01-01
The aim of this study was to determine the presence of organization of atrial activation processes during atrial fibrillation (AF) by assessing whether the activation sequences are wholly random or are governed by deterministic mechanisms. We performed both linear and nonlinear analyses based on the cross correlation function (CCF) and recurrence plot quantification (RPQ), respectively. Recurrence plots were quantified by three variables: percent recurrence (PR), percent determinism (PD), and entropy of recurrences (ER). We recorded bipolar intra-atrial electrograms in two atrial sites during chronic AF in 19 informed subjects, following two protocols. In one, both recording sites were in the right atrium; in the other protocol, one site was in the right atrium, the other one in the left atrium. We extracted 19 episodes of type I AF (Wells' classification). RPQ detected transient recurrent patterns in all the episodes, while CCF was significant only in ten episodes. Surrogate data analysis, based on a cross-phase randomization procedure, decreased PR, PD, and ER values. The detection of spatiotemporal recurrent patterns together with the surrogate data results indicate that during AF a certain degree of local organization exists, likely caused by deterministic mechanisms of activation.
A microcomputer system for on-line study of atrioventricular node accommodation.
Jenkins, J R; Clemo, H F; Belardinelli, L
1987-11-01
An automated on-line programmable stimulator and interval measurement system was developed to study atrioventricular node (AVN) accommodation. This dedicated microcomputer system measures and stores the stimulus-to-His bundle (S-H) interval from His bundle electrogram (HBE) recordings. Interval measurements for each beat are accurate to within 500 microsecond. This user-controlled system has been used to stimulate at any rate up to 6.5 Hz and to measure intervals up to 125 ms in isolated perfused guinea pig hearts. A built-in timer-reset mechanism prevents failure of the system in the absence of a His potential (i.e., 2:1 AV block). It may be modified for use in clinical studies or other experimental systems and has the ability to measure other physiological intervals. The system provides the precision in pacing and accuracy in the measurement of AVN conduction time that is necessary for meaningful analysis of AVN accommodation and has the simplicity of design and use that is not available in previously described systems. Furthermore, this computer system can be used not only in studies involving AV conduction, but also in any setting where programmed stimulation and interval measurement and recording need to be performed simultaneously.
Kong, Wei; Huang, Jian; Rollins, Dennis L; Ideker, Raymond E; Smith, William M
2007-03-01
We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and coronary artery blood flow and arterial blood pressure that are suitable for use with the system. The telemetry system consists of a front end, a backpack and a host PC. The front end is a watertight stainless steel case with all sensor electronics sealed inside; it acquires dimension, flow, pressure and five cardiac electrograms from selected locations on the heart. The backpack includes a control unit, Bluetooth radio, and batteries. The control unit digitizes eight channels of data from the front end and forwards them to the host PC via Bluetooth link. The host PC has a receiving Bluetooth radio and Labview programs to store and display data. The whole system was successfully tested on the bench and in an animal model. This telemetry system will greatly enhance the ability to study events leading to spontaneous sudden cardiac arrest.
Monigatti-Tenkorang, Joanna; Jousset, Florian; Pascale, Patrizio; Vesin, Jean-Marc; Ruchat, Patrick; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne
2014-04-01
Paroxysmal atrial fibrillation (AF) may be triggered by intermittent atrial tachycardia, and ultimately lead to persistent AF. However, the mechanisms by which intermittent atrial tachycardia promotes sustained AF are not well understood. Eight sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms, and for the delivery of electrophysiological stimulation protocols and intermittent right atrial tachycardia. Right atrial kinetics of activation recovery interval (ARI) as a surrogate for action potential duration, of conduction time and velocity, and of repolarization alternans were analyzed at incremental pacing rates during the remodeling process induced by weeks of intermittent atrial tachycardia until the development of sustained AF. Intermittent atrial tachycardia decreased ARI and blunted its rate adaptation, facilitated atrial capture, and slowed conduction at high rates, and increased susceptibility to pacing-induced AF. In spite of blunted ARI rate adaptation, right atrial repolarization alternans was maintained during remodeling, and further increased in magnitude just before rapid pacing-induced AF. This study suggests that weeks of intermittent right atrial tachycardia result in a gradual electrical remodeling favorable for wavebreaks and reentry that may facilitate fibrillation. © 2014 Wiley Periodicals, Inc.
Quaini, A; Canic, S; Glowinski, R; Igo, S; Hartley, C J; Zoghbi, W; Little, S
2012-01-10
This work presents a validation of a fluid-structure interaction computational model simulating the flow conditions in an in vitro mock heart chamber modeling mitral valve regurgitation during the ejection phase during which the trans-valvular pressure drop and valve displacement are not as large. The mock heart chamber was developed to study the use of 2D and 3D color Doppler techniques in imaging the clinically relevant complex intra-cardiac flow events associated with mitral regurgitation. Computational models are expected to play an important role in supporting, refining, and reinforcing the emerging 3D echocardiographic applications. We have developed a 3D computational fluid-structure interaction algorithm based on a semi-implicit, monolithic method, combined with an arbitrary Lagrangian-Eulerian approach to capture the fluid domain motion. The mock regurgitant mitral valve corresponding to an elastic plate with a geometric orifice, was modeled using 3D elasticity, while the blood flow was modeled using the 3D Navier-Stokes equations for an incompressible, viscous fluid. The two are coupled via the kinematic and dynamic conditions describing the two-way coupling. The pressure, the flow rate, and orifice plate displacement were measured and compared with numerical simulation results. In-line flow meter was used to measure the flow, pressure transducers were used to measure the pressure, and a Doppler method developed by one of the authors was used to measure the axial displacement of the orifice plate. The maximum recorded difference between experiment and numerical simulation for the flow rate was 4%, the pressure 3.6%, and for the orifice displacement 15%, showing excellent agreement between the two. Copyright © 2011 Elsevier Ltd. All rights reserved.
Barbiturate euthanasia solution-induced tissue artifact in nonhuman primates.
Grieves, J L; Dick, E J; Schlabritz-Loutsevich, N E; Butler, S D; Leland, M M; Price, S E; Schmidt, C R; Nathanielsz, P W; Hubbard, G B
2008-06-01
Barbiturate euthanasia solutions are a humane and approved means of euthanasia. Overdosing causes significant tissue damage in a variety of laboratory animals. One hundred seventeen non-human primates (NHP) representing 7 species including 12 fetuses euthanized for humane and research reasons by various vascular routes with Euthasol, Sodium Pentobarbital, Fatal Plus, Beuthanasia D, or Euthanasia 5 were evaluated for euthanasia-induced tissue damage. Lungs and livers were histologically graded for hemolysis, vascular damage, edema, and necrosis. Severity of tissue damage was analyzed for differences on the basis of agent, age, sex, dose, and injection route. Severity of tissue damage was directly related to dose and the intracardiac injection route, but did not differ by species, sex, and agent used. When the recommended dose of agent was used, tissue damage was generally reduced, minimal, or undetectable. Barbiturate-induced artifacts in NHPs are essentially the same as in other laboratory species.
Intracardiac metastasis originated from chondrosarcoma.
Maurea, Nicola; Ragone, Gianluca; Coppola, Carmela; Caronna, Antonietta; Tocchetti, Carlo G; Agozzino, Lucio; Apice, Gaetano; Iaffaioli, Rosario V
2017-05-01
Primary cardiac tumors are extremely rare. By comparison, metastatic involvement of the heart is over 20 times more common and has been reported in autopsy series in up to one in five patients dying of cancer. Cardiac metastasis of chondrosarcoma is absolutely not frequent. In the recent literature, a cardiac metastasis from chondrosarcoma has never been described. We report the case of an 18-year-old man with a diagnosis of cardiac metastasis that originated from a left scapular chondrosarcoma. Chondrosarcoma is a skeletal tumor with various grades of malignancy, rapidly evolving, and with a strong tendency to metastasize, with low responsiveness to chemotherapy. The onset of characteristic systemic symptoms in the late stage of the disease led to the diagnosis of a mass localized in the right atrium. Management and differential diagnosis of infective heart lesions were also very complex in a rapidly evolving life-threatening condition.
Determination of cardiac size from chest roentgenograms following Skylab missions
NASA Technical Reports Server (NTRS)
Nicogossian, A. E.; Hoffler, G. W.; Johnson, R. L.; Gowen, R. J.
1974-01-01
Decreased cardiothoracic transverse diameter ratios following Mercury, Gemini and Apollo space flights have been reported previously. To evaluate further changes in cardiac size, standard posteroanterior chest films in systole and diastole were obtained before flight and within a few hours after recovery on each of the Skylab astronauts. Postflight chest X-rays were visually compared to the preflight roentgenograms for possible changes in pulmonary vasculature, lung parenchyma, bony or soft tissue structures. From these roentgenograms the following measurements were obtained: cardiac and thoracic transverse diameters, cardiothoracic transverse diameter ratio, cardiac area from the product of both diagonal diameters, cardiac silhouette area by planimetry, thoracic cage area and cardiothoracic area ratio. The postflight frontal cardiac silhouette sizes were significantly decreased when compared with the respective preflight values (P0.05 or 0.01). The observed changes are thought to be related to postflight decrease in the intracardiac chamber volume.
Hussein, Nabil; Qamar, Sombul; Abid, Qamar
2015-01-01
Aspergillus infections such as Aspergillus endocarditis were once relatively rare occurrences, however, due to the increased use of intracardiac devices, the incidence has grown. With mortality rates close to 100%, in medically treated cases, it is paramount that early diagnosis and treatment are performed. An immunocompetent aviculturist presented 8 months post aortic root replacement for severe aortic regurgitation with a composite graft, with central crushing chest pain. Investigations confirmed ST elevation inferior myocardial infarction due to stenosis of the origin of the right coronary artery, which was stented. Echocardiogram demonstrated a mobile mass posterior to the left ventricular outflow tract. Following referral to our cardiothoracic surgeons, a polypoidal mass covering the right ostial button was noted along with systemic complications of the disease. Emergency redo aortic valve replacement with a homograft and coronary artery bypass was performed. Histological analysis confirmed A. fumigatus and the patient was started on intravenous voriconazole. PMID:26025972
Ouellette, Christopher P; Joshi, Sarita; Texter, Karen; Jaggi, Preeti
2017-05-01
Two children with congenital heart disease status post surgical correction presented with prolonged constitutional symptoms, hepatosplenomegaly and pancytopenia. Concern for malignancy prompted bone marrow biopsies that were without evidence thereof. In case 1, echocardiography identified a multilobulated vegetation on the conduit valve. In case 2, transthoracic, transesophageal and intracardiac echocardiography were performed and were without evidence of cardiac vegetations; however, pulmonic emboli raised concern for infective endocarditis. Both patients underwent surgical resection of the infected material and had histopathologic evidence of infective endocarditis. Further diagnostics identified elevated cytoplasmic antineutrophil cytoplasmic antibodies and antiproteinase 3 antibodies in addition to acute kidney injury with crescentic glomerulonephritis on renal biopsy. Serologic evidence of infection with Bartonella henselae was observed in both patients. These 2 cases highlight the potential multiorgan involvement that may confound the diagnosis of culture-negative infective endocarditis caused by B. henselae.
Thali, Michael J; Schweitzer, Wolf; Yen, Kathrin; Vock, Peter; Ozdoba, Christoph; Spielvogel, Elke; Dirnhofer, Richard
2003-03-01
The goal of this study was the full-body documentation of a gunshot wound victim with multislice helical computed tomography for subsequent comparison with the findings of the standard forensic autopsy. Complete volume data of the head, neck, and trunk were acquired by use of two acquisitions of less than 1 minute of total scanning time. Subsequent two-dimensional multiplanar reformations and three-dimensional shaded surface display reconstructions helped document the gunshot-created skull fractures and brain injuries, including the wound track, and the intracerebral bone fragments. Computed tomography also demonstrated intracardiac air embolism and pulmonary aspiration of blood resulting from bullet wound-related trauma. The "digital autopsy," even when postprocessing time was added, was more rapid than the classic forensic autopsy and, based on the nondestructive approach, offered certain advantages in comparison with the forensic autopsy.
Transient right-to-left shunt in massive pulmonary embolism.
Panoutsopoulos, G; Ilias, L; Christakopoulou, I
2000-06-01
A 56-yr-old man, two months after an operation for an acoustic neurinoma, gradually developed dyspnea. Massive pulmonary embolism (MPE), with a significant right-to-left (R-L) shunt, was seen in a perfusion scan of the lungs with Tc-99m MAA. Radioactivity was noted in the thyroid, spleen, kidneys and brain. A cardiac ultrasound study did not reveal intracardiac shunting. A few days later, when the patient's condition improved, another perfusion scan of the lungs did not show the shunt, whereas a subsequent digital subtraction angiographic study confirmed the diagnosis of MPE but failed to reveal the cause of the shunt. In the absence of any possible pathophysiological mechanism, to explain the observed R-L shunt, we deduce that the particles of Tc-99m MAA might have passed through the precapillary pulmonary arteriovenous anastomoses and/or through dilated pulmonary capillaries, as a result of highly increased pulmonary vascular pressure due to MPE.
Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools
Gosline, Andrew H; Vasilyev, Nikolay V; Butler, Evan J; Folk, Chris; Cohen, Adam; Chen, Rich; Lang, Nora; del Nido, Pedro J; Dupont, Pierre E
2013-01-01
Achieving superior outcomes through the use of robots in medical applications requires an integrated approach to the design of the robot, tooling and the procedure itself. In this paper, this approach is applied to develop a robotic technique for closing abnormal communication between the atria of the heart. The goal is to achieve the efficacy of surgical closure as performed on a stopped, open heart with the reduced risk and trauma of a beating-heart catheter-based procedure. In the proposed approach, a concentric tube robot is used to percutaneously access the right atrium and deploy a tissue approximation device. The device is constructed using a metal microelectromechanical system (MEMS) fabrication process and is designed to both fit the manipulation capabilities of the robot as well as to reproduce the beneficial features of surgical closure by suture. The effectiveness of the approach is demonstrated through ex vivo and in vivo experiments. PMID:23750066
Reich, H; Czer, L; Bannykh, S; De Robertis, M; Wolin, E; Amersi, F; Moriguchi, J; Kobashigawa, J; Arabia, F
2015-09-01
Malignancy is the leading cause of long-term morbidity and mortality after heart and other solid organ transplantation; therefore, great emphasis is placed on pre- and post-transplantation cancer screening. Even with meticulous screening during evaluation for heart transplant candidacy, an occult cancer may not be apparent. Here, we share the case of a 51-year-old man with refractory heart failure who underwent total artificial heart implantation as a bridge to transplantation with the surprise finding of an isolated deposit of metastatic carcinoid tumor nested within a left ventricular papillary muscle in his explanted heart. The primary ileal carcinoid tumor was identified and resected completely. After remaining cancer-free for 14 months, he was listed for heart transplantation and was transplanted 2 months later. He is currently 3.5 months out from heart transplantation and doing well, without evidence of recurring malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.
Review: Intracardiac intracellular angiotensin system in diabetes
Kumar, Rajesh; Yong, Qian Chen; Thomas, Candice M.
2012-01-01
The renin-angiotensin system (RAS) has mainly been categorized as a circulating and a local tissue RAS. A new component of the local system, known as the intracellular RAS, has recently been described. The intracellular RAS is defined as synthesis and action of ANG II intracellularly. This RAS appears to differ from the circulating and the local RAS, in terms of components and the mechanism of action. These differences may alter treatment strategies that target the RAS in several pathological conditions. Recent work from our laboratory has demonstrated significant upregulation of the cardiac, intracellular RAS in diabetes, which is associated with cardiac dysfunction. Here, we have reviewed evidence supporting an intracellular RAS in different cell types, ANG II's actions in cardiac cells, and its mechanism of action, focusing on the intracellular cardiac RAS in diabetes. We have discussed the significance of an intracellular RAS in cardiac pathophysiology and implications for potential therapies. PMID:22170614
Mancuso, G; Tomasello, F; von Hunolstein, C; Orefici, G; Teti, G
1994-01-01
Previous studies suggested that circulating tumor necrosis factor alpha (TNF-alpha) may have a pathophysiologic role in experimental neonatal sepsis induced by group B streptococci (GBS). This study was undertaken to investigate the ability of the type III and group-specific polysaccharides of GBS to induce TNF-alpha production and TNF-alpha-dependent lethality in neonatal rats. The cytokine was detected in plasma samples by the L929 cytotoxicity assay. Intracardiac injections of either polysaccharide induced dose-dependent, transient elevations in plasma TNF-alpha levels that returned to baseline values after 5 h. The group-specific antigen induced significantly higher mean peak TNF-alpha levels than the type III antigen (125 +/- 47 versus 44 +/- 15 U/ml with 70 mg/kg of body weight). Glycogen (70 mg/kg), used as a negative control, did not induce TNF-alpha. The lipopolysaccharide-neutralizing agent polymyxin B did not decrease TNF-alpha levels induced by either polysaccharide, ruling out contamination with endotoxin as a possible cause of TNF-alpha induction. Fifty percent lethal doses of the type III and group-specific antigens given as intracardiac injections were 105 and 16 mg/kg, respectively. Salmonella endotoxin, used as a positive control, had a 50% lethal dose of 0.1 mg/kg. The lethal activities of GBS polysaccharides, as well as endotoxin, were completely prevented by pretreatment of neonatal rats with the respective specific antibodies or anti-murine TNF-alpha serum. To assess the relative importance of the type-specific substance in TNF-alpha induction by whole bacteria, two unrelated GBS transposon mutants devoid of only the type-specific capsular polysaccharide (COH1-13 and COH31-15) were employed. Each of the heat-killed unencapsulated mutants was able to produce plasma TNF-alpha level elevations or TNF-alpha-dependent lethality but was significantly less efficient in these activities than the corresponding encapsulated wild-type strain. These data suggest that the presence of type-specific material on GBS is not necessary for the stimulation of TNF-alpha production. Type III capsular polysaccharide, however, can significantly increase the ability of GBS to induce TNF-alpha. Further studies will be needed to assess the importance of TNF-alpha induction by the group- and type-specific antigens in the pathophysiology of GBS disease. PMID:8005664
Patel, Angira; Cao, Qi-Ling; Koenig, Peter R; Hijazi, Ziyad M
2006-08-01
Intracardiac echocardiography (ICE) is increasingly replacing transesophageal echocardiography (TEE) as the primary imaging technique to guide device closure of atrial septal defects (ASD). Owing to the length of the procedure, the use of TEE requires general anesthesia. Investigators have reported the usefulness of ICE in adults and children. However, little is known about the use of ICE in children whose weight is <15 kg. Therefore, this study examines the use of ICE guided secundum ASD closure in children <15 kg. Nineteen patients with a median age of 3.1 years (range 1.8-4.8), and median weight of 13.2 kg (range 8.0-14.4) underwent transcatheter occlusion (Amplatzer occluder) of a secundum ASD using ICE guidance. ICE was performed using an Acunav catheter. The ICE catheter (10 F shaft) was introduced into an 11 F sheath in a contralateral femoral vein. Diagnostic as well as periprocedure imaging was obtained. Sixteen patients had single, and three had multiple defects. Median defect size as measured by ICE was 16 mm (range 2.5-25). The median balloon stretched diameter (obtained in eight patients) was 18 mm (range 10-21); the median size of the defect for these eight patients was 15 mm (range of 8-20). Both techniques for measuring the defect correlated well with r = 0.94. The ASD occluder size ranged from 7 to 26 mm with a median of 18 mm. The procedure was successful in 16 patients who had a device implanted and no residual shunt. ASD occlusion was not attempted in two patients due to deficient rims and in one patient, the attempt failed due to left atrial disk prolapse through the ASD. Four patients experienced transient complications during the catheter procedure, including supra ventricular tachycardia, sinus bradycardia, and two with complete heart block (resolving with device removal); all had subsequent successful device placement. No complications were attributed to the use of ICE and specifically, no vascular injury was noted. Comparable to results with larger patients, ICE provides adequate imaging (preprocedure diagnosis and periprocedure guidance) during device occlusion of secundum ASDs with no significant complications. Thus, ICE can successfully be used in the closure of ASD in smaller patients (<15 kg) and eliminate the need for endotracheal intubation.
Development of glia and blood vessels in the internal capsule of rats.
Earle, K L; Mitrofanis, J
1998-02-01
We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified microglia are seen in the thalamus. In summary, our results indicate that all three types of glia in the internal capsule are associated closely with the vasculature, suggesting they may play a role in the development of the blood-brain barrier among the vessels in this white matter region of the forebrain.
Development of Novel Patient-Derived Xenografts from Breast Cancer Brain Metastases
Contreras-Zárate, María J.; Ormond, D. Ryan; Gillen, Austin E.; Hanna, Colton; Day, Nicole L.; Serkova, Natalie J.; Jacobsen, Britta M.; Edgerton, Susan M.; Thor, Ann D.; Borges, Virginia F.; Lillehei, Kevin O.; Graner, Michael W.; Kabos, Peter; Cittelly, Diana M.
2017-01-01
Brain metastases are an increasing burden among breast cancer patients, particularly for those with HER2+ and triple negative (TN) subtypes. Mechanistic insight into the pathophysiology of brain metastases and preclinical validation of therapies has relied almost exclusively on intracardiac injection of brain-homing cells derived from highly aggressive TN MDA-MB-231 and HER2+ BT474 breast cancer cell lines. Yet, these well characterized models are far from representing the tumor heterogeneity observed clinically and, due to their fast progression in vivo, their suitability to validate therapies for established brain metastasis remains limited. The goal of this study was to develop and characterize novel human brain metastasis breast cancer patient-derived xenografts (BM-PDXs) to study the biology of brain metastasis and to serve as tools for testing novel therapeutic approaches. We obtained freshly resected brain metastases from consenting donors with breast cancer. Tissue was immediately implanted in the mammary fat pad of female immunocompromised mice and expanded as BM-PDXs. Brain metastases from 3/4 (75%) TN, 1/1 (100%) estrogen receptor positive (ER+), and 5/9 (55.5%) HER2+ clinical subtypes were established as transplantable BM-PDXs. To facilitate tracking of metastatic dissemination using BM-PDXs, we labeled PDX-dissociated cells with EGFP-luciferase followed by reimplantation in mice, and generated a BM-derived cell line (F2-7). Immunohistologic analyses demonstrated that parental and labeled BM-PDXs retained expression of critical clinical markers such as ER, progesterone receptor, epidermal growth factor receptor, HER2, and the basal cell marker cytokeratin 5. Similarly, RNA sequencing analysis showed clustering of parental, labeled BM-PDXs and their corresponding cell line derivative. Intracardiac injection of dissociated cells from BM-E22-1, resulted in magnetic resonance imaging-detectable macrometastases in 4/8 (50%) and micrometastases (8/8) (100%) mice, suggesting that BM-PDXs remain capable of colonizing the brain at high frequencies. Brain metastases developed 8–12 weeks after ic injection, located to the brain parenchyma, grew around blood vessels, and elicited astroglia activation characteristic of breast cancer brain metastasis. These novel BM-PDXs represent heterogeneous and clinically relevant models to study mechanisms of brain metastatic colonization, with the added benefit of a slower progression rate that makes them suitable for preclinical testing of drugs in therapeutic settings. PMID:29164052
Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak
2009-08-01
Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and (2) the ability to ability to demonstrate certain structures in an "en face" view, which is not offered by any other currently available real-time imaging technique, enabling appreciation of the exact nature of the lesion that is undergoing intervention. RT3D TEE is a powerful new imaging tool that may become the technique of choice and the standard of care for guidance of selected percutaneous catheter-based procedures.
Dezfulian, Cameron; Shiva, Sruti; Alekseyenko, Aleksey; Pendyal, Akshay; Beiser, DG; Munasinghe, Jeeva P.; Anderson, Stasia A.; Chesley, Christopher F.; Hoek, TL Vanden; Gladwin, Mark T.
2009-01-01
Background Three-fourths of cardiac arrest survivors die prior to hospital discharge or suffer significant neurological injury. Excepting therapeutic hypothermia and revascularization, no novel therapies have been developed that improve survival or cardiac and neurological function after resuscitation. Nitrite (NO2−) increases cellular resilience to focal ischemia-reperfusion injury in multiple organs. We hypothesized that nitrite therapy may improve outcomes after the unique global ischemia-reperfusion insult of cardiopulmonary arrest. Methods and Results We developed a mouse model of cardiac arrest characterized by 12-minutes of normothermic asystole and a high cardiopulmonary resuscitation (CPR) rate. In this model, global ischemia and CPR was associated with blood and organ nitrite depletion, reversible myocardial dysfunction, impaired alveolar gas exchange, neurological injury and an approximate 50% mortality. A single low dose of intravenous nitrite (50 nmol=1.85 μmol/kg=0.13 mg/kg) compared to blinded saline placebo given at CPR initiation with epinephrine improved cardiac function, survival and neurological outcomes. From a mechanistic standpoint, nitrite treatment restored intracardiac nitrite and increased S-nitrosothiol levels, decreased pathological cardiac mitochondrial oxygen consumption due to reactive oxygen species formation and prevented oxidative enzymatic injury via reversible specific inhibition of respiratory chain complex I. Conclusion Nitrite therapy after resuscitation from 12-minutes of asystole rapidly and reversibly modulated mitochondrial reactive oxygen species generation during early reperfusion, limiting acute cardiac dysfunction and death, as well as neurological impairment in survivors. PMID:19704094
Robotic mitral valve surgery: overview, methodology, results, and perspective
2016-01-01
Robotic mitral valve repair began in 1998 and has advanced remarkably. It arose from an interest in reducing patient trauma by operating through smaller incisions with videoscopic assistance. In the United States, following two clinical trials, the FDA approved the daVinci Surgical System in 2002 for intra-cardiac surgery. This device has undergone three iterations, eventuating in the current daVinci XI. At present it is the only robotic device approved for mitral valve surgery. Many larger centers have adopted its use as part of their routine mitral valve repair armamentarium. Although these operations have longer perfusion and arrest times, complications have been either similar or less than other traditional methods. Preoperative screening is paramount and leads to optimal patient selection and outcomes. There are clear contraindications, both relative and absolute, that must be considered. Three-dimensional (3D) echocardiographic studies optimally guide surgeons in operative planning. Herein, we describe the selection criteria as well as our operative management during a robotic mitral valve repair. Major complications are detailed with tips to avoid their occurrence. Operative outcomes from the author’s series as well as those from the largest experiences in the United States are described. They show that robotic mitral valve repair is safe and effective, as well as economically reasonable due to lower costs of hospitalization. Thus, the future of this operative technique is bright for centers adopting the “heart team” approach, adequate clinical volume and a dedicated and experienced mitral repair surgeon. PMID:27942486
Functional health status of adolescents after the Fontan procedure – comparison with their siblings
Manlhiot, Cedric; Knezevich, Stevan; Radojewski, Elizabeth; Cullen-Dean, Geraldine; Williams, William G; McCrindle, Brian W
2009-01-01
BACKGROUND: Studies have suggested that patients who have undergone the Fontan procedure experience lower functional health status and diminished exercise capacity compared with other children. OBJECTIVES: To compare the functional health status of Fontan patients with and without siblings, assess whether there are any differences between Fontan patients and their siblings, and determine associated factors. METHODS: A cross-sectional, single-centre, observational study was performed on Fontan patients 10 to 20 years of age, and their sibling closest in age, followed in a tertiary pediatric hospital. Functional health status was measured by the Child Health Questionnaire Child Form and the Pediatric Quality of Life Inventory. RESULTS: A total of 68 patients and 38 siblings were enrolled. Patients with siblings scored significantly lower on numerous domains of physical functional status than those without siblings. Compared with their matched siblings, Fontan patients reported significantly lower scores in all domains of the Pediatric Quality of Life Inventory and on physical (but not psychosocial) domains of the Child Health Questionnaire Child Form. Factors associated with increased patient-sibling differences included younger patient age, female sex, intracardiac lateral tunnel Fontan connection and lower ejection fraction at the time of study enrollment. CONCLUSIONS: Adolescents with Fontan physiology reported a lower functional health status in physical domains than their siblings, but had similar status in psychosocial domains. Having a sibling was associated with lower reported functional health status, suggesting an important effect of self-perceived physical limitations over true limitations. PMID:19746247
Transatrial Intrapericardial Tricuspid Annuloplasty
Rogers, Toby; Ratnayaka, Kanishka; Sonmez, Merdim; Franson, Dominique N.; Schenke, William H.; Mazal, Jonathan R.; Kocaturk, Ozgur; Chen, Marcus Y.; Faranesh, Anthony Z.; Lederman, Robert J.
2015-01-01
OBJECTIVES This study sought to demonstrate transcatheter deployment of a circumferential device within the pericardial space to modify tricuspid annular dimensions interactively and to reduce functional tricuspid regurgitation (TR) in swine. BACKGROUND Functional TR is common and is associated with increased morbidity and mortality. There are no reported transcatheter tricuspid valve repairs. We describe a transcatheter extracardiac tricuspid annuloplasty device positioned in the pericardial space and delivered by puncture through the right atrial appendage. We demonstrate acute and chronic feasibility in swine. METHODS Transatrial intrapericardial tricuspid annuloplasty (TRAIPTA) was performed in 16 Yorkshire swine, including 4 with functional TR. Invasive hemodynamics and cardiac magnetic resonance imaging (MRI) were performed at baseline, immediately after annuloplasty and at follow-up. RESULTS Pericardial access via a right atrial appendage puncture was uncomplicated. In 9 naïve animals, tricuspid septal-lateral and anteroposterior dimensions, the annular area and perimeter, were reduced by 49%, 31%, 59%, and 24% (p < 0.001), respectively. Tricuspid leaflet coaptation length was increased by 53% (p < 0.001). Tricuspid geometric changes were maintained after 9.7 days (range, 7 to 14 days). Small effusions (mean, 46 ml) were observed immediately post-procedure but resolved completely at follow-up. In 4 animals with functional TR, severity of regurgitation by intracardiac echocardiography was reduced. CONCLUSIONS Transatrial intrapericardial tricuspid annuloplasty is a transcatheter extracardiac tricuspid valve repair performed by exiting the heart from within via a transatrial puncture. The geometry of the tricuspid annulus can interactively be modified to reduce severity of functional TR in an animal model. PMID:25703872
Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors
Khoury, Dirar S.; Naware, Mihir; Siou, Jeff; Blomqvist, Andreas; Mathuria, Nilesh S.; Wang, Jianwen; Shih, Hue-Teh; Nagueh, Sherif F.; Panescu, Dorin
2009-01-01
Objectives To investigate properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy (CRT) system. Background Monitoring of CHF has relied mainly on right-heart sensors. Methods Fifteen normal dogs underwent implantation of CRT systems using standard leads. An additional left atrial (LA) pressure lead-sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathorcaic and intracardiac vectors, were measured via ring (r), coil (c), and device Can electrodes. Results All animals developed CHF after 2–4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LVr-Can, −17%; LVr-RVr, −15%; LVr-RAr, −11%; RVr-Can, −12%; RVc-Can, −7%; RAr-Can, −5%. The LVr-Can vector reflected both the fastest and largest change in impedance in comparison to vectors employing only right-heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired via different lead-electrodes, have variable responses to CHF. Impedance vectors employing a LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. PMID:19298923
Savard, P; Cardinal, R; Nadeau, R A; Armour, J A
1991-06-01
Sixty-three ventricular epicardial electrograms were recorded simultaneously in 8 atropinized dogs during stimulation of acutely decentralized intrathoracic autonomic ganglia or cardiopulmonary nerves. Three variables were measured: (1) isochronal maps representing the epicardial activation sequence, (2) maps depicting changes in areas under the QRS complex and T wave (regional inhomogeneity of repolarization), and (3) local and total QT intervals. Neural stimulations did not alter the activation sequence but induced changes in the magnitude and polarity of the ST segments and T waves as well as in QRST areas. Stimulation of the same neural structure in different dogs induced electrical changes with different amplitudes and in different regions of the ventricles, except for the ventral lateral cardiopulmonary nerve which usually affected the dorsal wall of the left ventricle. Greatest changes occurred when the right recurrent, left intermediate medial, left caudal pole, left ventral lateral cardiopulmonary nerves and stellate ganglia were stimulated. Local QT durations either decreased or did not change, whereas total QT duration as measured using a root-mean-square signal did not change, indicating the regional nature of repolarization changes. Taken together, these data indicate that intrathoracic efferent sympathetic neurons can induce regional inhomogeneity of repolarization without prolonging the total QT interval.
Kulboka, Arūnas; Veikutis, Vincentas; Pauza, Dainius Haroldas; Lekas, Raimundas
2003-01-01
The aims of present study were to verify the topography of the intracardiac nerve subplexuses (INS) by using electrophysiological methods, its relations with sinoatrial (SA) node function and to investigate possibility of selective surgical SA node denervation. Fifteen mongrel dogs of either sex weighing 8 to 15 kg were used for electrophysiological studies. Both cervical vagosympathetic trunks were isolated and crushed by tight ligatures. Nervus subplexuses destructions were performed by cryocoagulation in three zones located around the right superior vena cava: ventral, lateral and dorsal. The sinus rhythm, SA node function recovery time, AV node conductivity, AV node and atrial effective refractory period were measured. Five experiments in each of three zones were performed. Experimental data show that destruction of the epicardial nerves has different effect on electrophysiological parameters. After destruction of the anterior zone of the right atrium the sinus rhythm decreased on an average by 11.6%; SA node function recovery time prolonged by 7.2%; AV node conductivity decreased by 13.1%; AV node effective refractory period prolonged by 12.9% and atrial effective refractory period, by 10.9 %. Measurements of electrophysiological parameters after intravenous injection of atropine sulphate show that sinus rhythm decreased on an average by 23.4%; SA node function recovery time increased by 9.1%; the conductivity of AV node decreased by 10.2%; AV node effective refractory period prolonged by 15.4% and atrial effective refractory period, by 13.2%. After destruction of the intracardiac nerves of the lateral zone, the sinus rhythm decreased by 15.7%; SA node function recovery time increased by 16.3%; AV node conductivity decreased by 8.3%; AV node effective refractory period and atrial effective refractory period prolonged by 11.9% and 10.0%, respectively. After the atropine sulphate intravenous injection, the sinus rhythm decreased on an average by 7.1%, SA node function recovery time prolonged by 7.1%, AV conductivity decreased by 9.1%, AV node effective refractory period increased by 12.4%, and atrial effective refractory period prolonged by 12.5%. After destruction of the nerves in the dorsal zone the changes of electrophysiological parameters were opposite to those obtained after destruction of the nerve tracts in the anterior or lateral zones: the sinus rhythm increased on an average by 4.3%; SA node function recovery time shortened by 8.8%; AV conductivity increased by 9.7%; AV node and atrial effective refractory period decreased by 12.3% and 12.1%, respectively. After intravenous atropine sulphate infusion, sinus rhythm decreased on an average by 8.3%; SA node function recovery time prolonged by 9.6%; AV node conductivity decreased by 5%; AV node and atrial effective refractory period prolonged by 4.2% and 5.2%, respectively. The average changes of electrophysiological parameters before and after INS destruction shows that cryocoagulation of ventral and lateral zones eliminates the effects of sympathetic tone to SA and AV nodal activity. Cryocoagulation of dorsal zone eliminates the effects of nervus vagus to both nodal structures. These findings shows the possibility alter or correct SA node function by making selective surgical SA node denervation.
Software algorithm and hardware design for real-time implementation of new spectral estimator
2014-01-01
Background Real-time spectral analyzers can be difficult to implement for PC computer-based systems because of the potential for high computational cost, and algorithm complexity. In this work a new spectral estimator (NSE) is developed for real-time analysis, and compared with the discrete Fourier transform (DFT). Method Clinical data in the form of 216 fractionated atrial electrogram sequences were used as inputs. The sample rate for acquisition was 977 Hz, or approximately 1 millisecond between digital samples. Real-time NSE power spectra were generated for 16,384 consecutive data points. The same data sequences were used for spectral calculation using a radix-2 implementation of the DFT. The NSE algorithm was also developed for implementation as a real-time spectral analyzer electronic circuit board. Results The average interval for a single real-time spectral calculation in software was 3.29 μs for NSE versus 504.5 μs for DFT. Thus for real-time spectral analysis, the NSE algorithm is approximately 150× faster than the DFT. Over a 1 millisecond sampling period, the NSE algorithm had the capability to spectrally analyze a maximum of 303 data channels, while the DFT algorithm could only analyze a single channel. Moreover, for the 8 second sequences, the NSE spectral resolution in the 3-12 Hz range was 0.037 Hz while the DFT spectral resolution was only 0.122 Hz. The NSE was also found to be implementable as a standalone spectral analyzer board using approximately 26 integrated circuits at a cost of approximately $500. The software files used for analysis are included as a supplement, please see the Additional files 1 and 2. Conclusions The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra. The algorithm may be helpful to guide radiofrequency catheter ablation in real time. PMID:24886214
Luther, Vishal; Qureshi, Norman; Lim, Phang Boon; Koa-Wing, Michael; Jamil-Copley, Shahnaz; Ng, Fu Siong; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa; Linton, Nick
2018-03-01
Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P = 0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach. © 2018 Wiley Periodicals, Inc.
T-wave loop area from a pre-implant 12-lead ECG is associated with appropriate ICD shocks
Hnatkova, Katerina; Friede, Tim; Malik, Marek; Zabel, Markus
2017-01-01
Aims In implantable cardioverter-defibrillator (ICD) patients, predictors of ICD shocks and mortality are needed to improve patient selection. Electrocardiographic (ECG) markers are simple to obtain and have been demonstrated to predict mortality. We aimed to assess the association of T-wave loop area and circularity with ICD shocks. Methods The study investigated patients with ICDs implanted between 1998 and 2010 for whom digital 12-lead ECGs (Schiller CS200 ECG-Network) of sufficient quality were obtained within 1 month prior to the implantation. T-wave loop area and circularity were calculated. Follow-up data of appropriate shocks were obtained during ICD clinic visits that included reviews of device stored electrograms. Results A total of 605 patients (82% males) were included; 68% had ischemic cardiomyopathy and 72% were treated for primary prevention. Over 3.8±1.4 years of follow-up, 114 patients (19%) experienced appropriate shock(s). Those with smaller T-wave loop area received fewer shocks (TLA, hazard ratio, HR, per increase of 1 technical unit, 0.71; [95% confidence interval, 0.53–0.94]; P = 0.02) and those with larger T-wave loop circularity (TLC) representing rounder T wave loop received more shocks (HR per 1% TLC increase 2.96; [0.85–10.36]; P = 0.09). When the quartile containing the largest TLA and TLC values, respectively, were compared to the remaining cases, TLA remained significantly associated with fewer and TLC with more frequent shocks also after multivariate adjustment for clinical variables (HR, 0.59 [0.35–0.99], P = 0.044; and 1.64 [1.08–2.49], P = 0.021, respectively). Conclusions The size and shape of the T-wave loop calculated from pre-implantation 12-lead ECGs are associated with appropriate ICD shocks. PMID:28291831
A Blood-Resistant Surgical Glue for Minimally Invasive Repair of Vessels and Heart Defects
Lang, Nora; Pereira, Maria J.; Lee, Yuhan; Friehs, Ingeborg; Vasilyev, Nikolay V.; Feins, Eric N.; Ablasser, Klemens; O'Cearbhaill, Eoin D.; Xu, Chenjie; Fabozzo, Assunta; Padera, Robert; Wasserman, Steve; Freudenthal, Franz; Ferreira, Lino S.; Langer, Robert
2014-01-01
Currently, there are no clinically approved surgical glues that are nontoxic, bind strongly to tissue, and work well within wet and highly dynamic environments within the body. This is especially relevant to minimally invasive surgery that is increasingly performed to reduce postoperative complications, recovery times, and patient discomfort. We describe the engineering of a bioinspired elastic and biocompatible hydrophobic light-activated adhesive (HLAA) that achieves a strong level of adhesion to wet tissue and is not compromised by preexposure to blood. The HLAA provided an on-demand hemostatic seal, within seconds of light application, when applied to high-pressure large blood vessels and cardiac wall defects in pigs. HLAA-coated patches attached to the interventricular septum in a beating porcine heart and resisted supraphysiologic pressures by remaining attached for 24 hours, which is relevant to intracardiac interventions in humans. The HLAA could be used for many cardiovascular and surgical applications, with immediate application in repair of vascular defects and surgical hemostasis. PMID:24401941
Cárdenas Medellín, M L; Serna Saldívar, S O; Velazco de la Garza, J
1998-12-01
Two different concentrations (approx. 6 and 12%) and two presentations (raw and cooked) of dehydrated nopal were fed to laboratory rats and growth and serum total cholesterol, lipoprotein profile and glucose determined. Samples of raw and cooked nopal were chemically characterized for moisture, protein, ash, crude fiber, ether extract, total dietary fiber, reducing sugars, amino acids, minerals and gross energy. Cooking slightly affected some of the nutrients analyzed. After one month feeding, blood was withdrawn via intracardiac puncture and serum glucose, total cholesterol, HDL, LDL, and VLDL were determined. Rats fed 12% nopal had lower weight gains (P < 0.05) when compared with counterparts fed 6% nopal or the control diet. Consumption of nopal did not affect (P > 0.05) glucose, total cholesterol and HDL cholesterol levels. However, rats fed raw nopal at the 12% concentration level had a 34% reduction in LDL cholesterol levels; thus, it was concluded that raw nopal had a potentially beneficial effect for hypercholesterolemic individuals.
Smetnev, A S; Islam, M N; Sokolov, S F; Golitsyn, S P; Bankuzov, V A; Malakhov, V I
1990-02-01
27 patients underwent serial electrophysiological studies by using transesophageal atrial stimulation. A-V nodal reciprocal tachycardia was documented by intracardiac electrophysiological examinations. Sustained tachycardia was induced in all the patients before drug administration. On day 4 after oral verapamil, 320 mg/day, ethmosine, 800 mg/day, and ethacizine, 150 mg/day, the patients were subjected to transesophageal atrial stimulation. An antiarrhythmic effect was regarded to be reached if the authors failed to induced sustained tachycardias again. Verapamil, ethmosine, and ethacizine were found to be beneficial in 21 (78%), 13 (48%) and 21 (78%) patients, respectively. A comparative analysis demonstrated that ethacisine was not inferior to verapamil, but ethmosine produced less effects than verapamil and ethacizine. The crossover and individual efficacy shown by each drug suggests that it is necessary to use the technique of serial testing and to choose beneficial drugs from a possibly wide range of medicaments for each patient.
Ben-Or, Sharon; Nifong, L Wiley; Chitwood, W Randolph
2013-01-01
In July 2000, the da Vinci Surgical System (Intuitive Surgical, Inc) received Food and Drug Administration approval for intracardiac applications, and the first mitral valve repair was done at the East Carolina Heart Institute in May 2000. The system is now approved and used in many surgical specialties. With this disruptive technology and accepted use, surgeons and hospitals are seeking the most efficacious training pathway leading to safe use and responsible credentialing.One of the most important issues related to safe use is assembling the appropriate team of professionals involved with patient care. Moreover, proper patient selection and setting obtainable goals are also important.Creation and maintenance of a successful program are discussed in the article focusing on realistic goals. This begins with a partnership between surgeon leaders, hospital administrators, and industry support. Through this partnership, an appropriate training pathway and clinical pathway for success can be outlined. A timeline can then be created with periods of data analysis and adjustments as necessary. A successful program is attainable by following this pathway and attending to every detail along the journey.
Managing Chemotherapy-Related Cardiotoxicity in Survivors of Childhood Cancers
Lipshultz, Steven E.; Diamond, Melissa B.; Franco, Vivian I.; Aggarwal, Sanjeev; Leger, Kasey; Santos, Maria Verônica; Sallan, Stephen E.; Chow, Eric J.
2015-01-01
In the US, children diagnosed with cancer are living longer, but not without consequences from the same drugs that cured their cancer. In these patients, cardiovascular disease is the leading cause of non-cancer-related morbidity and mortality. Although this review focuses on anthracycline-related cardiomyopathy in childhood cancer survivors, the global lifetime risk of other cardiovascular diseases such as atherosclerosis, arrhythmias and intracardiac conduction abnormalities, hypertension, and stroke also are increased. Besides anthracyclines, newer molecularly targeted agents, such as vascular endothelial growth factor receptor and tyrosine kinase inhibitors, also have been associated with acute hypertension, cardiomyopathy, increased risk of ischemic cardiac events and arrhythmias, and are summarized here. This review also covers other risk factors for chemotherapy-related cardiotoxicity (including both modifiable and non-modifiable factors), monitoring strategies (including both blood and imaging-based biomarkers) during and following cancer treatment, and discusses the management of cardiotoxicity (including prevention strategies such as cardioprotection by use of dexrazoxane). PMID:25134924
Implantable Hemodynamic Monitoring for Heart Failure Patients.
Abraham, William T; Perl, Leor
2017-07-18
Rates of heart failure hospitalization remain unacceptably high. Such hospitalizations are associated with substantial patient, caregiver, and economic costs. Randomized controlled trials of noninvasive telemedical systems have failed to demonstrate reduced rates of hospitalization. The failure of these technologies may be due to the limitations of the signals measured. Intracardiac and pulmonary artery pressure-guided management has become a focus of hospitalization reduction in heart failure. Early studies using implantable hemodynamic monitors demonstrated the potential of pressure-based heart failure management, whereas subsequent studies confirmed the clinical utility of this approach. One large pivotal trial proved the safety and efficacy of pulmonary artery pressure-guided heart failure management, showing a marked reduction in heart failure hospitalizations in patients randomized to active pressure-guided management. "Next-generation" implantable hemodynamic monitors are in development, and novel approaches for the use of this data promise to expand the use of pressure-guided heart failure management. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Feasibility Study on Cardiac Arrhythmia Ablation Using High-Energy Heavy Ion Beams
NASA Astrophysics Data System (ADS)
Lehmann, H. Immo; Graeff, Christian; Simoniello, Palma; Constantinescu, Anna; Takami, Mitsuru; Lugenbiel, Patrick; Richter, Daniel; Eichhorn, Anna; Prall, Matthias; Kaderka, Robert; Fiedler, Fine; Helmbrecht, Stephan; Fournier, Claudia; Erbeldinger, Nadine; Rahm, Ann-Kathrin; Rivinius, Rasmus; Thomas, Dierk; Katus, Hugo A.; Johnson, Susan B.; Parker, Kay D.; Debus, Jürgen; Asirvatham, Samuel J.; Bert, Christoph; Durante, Marco; Packer, Douglas L.
2016-12-01
High-energy ion beams are successfully used in cancer therapy and precisely deliver high doses of ionizing radiation to small deep-seated target volumes. A similar noninvasive treatment modality for cardiac arrhythmias was tested here. This study used high-energy carbon ions for ablation of cardiac tissue in pigs. Doses of 25, 40, and 55 Gy were applied in forced-breath-hold to the atrioventricular junction, left atrial pulmonary vein junction, and freewall left ventricle of intact animals. Procedural success was tracked by (1.) in-beam positron-emission tomography (PET) imaging; (2.) intracardiac voltage mapping with visible lesion on ultrasound; (3.) lesion outcomes in pathohistolgy. High doses (40-55 Gy) caused slowing and interruption of cardiac impulse propagation. Target fibrosis was the main mediator of the ablation effect. In irradiated tissue, apoptosis was present after 3, but not 6 months. Our study shows feasibility to use high-energy ion beams for creation of cardiac lesions that chronically interrupt cardiac conduction.
The rodent liver undergoes weaning-induced involution and supports breast cancer metastasis
Goddard, Erica T.; Hill, Ryan C.; Nemkov, Travis; D’Alessandro, Angelo; Hansen, Kirk C.; Maller, Ori; Mongoue-Tchokote, Solange; Mori, Motomi; Partridge, Ann H.; Borges, Virginia F.; Schedin, Pepper
2017-01-01
Postpartum breast cancer patients are at increased risk for metastasis compared to age-matched nulliparous or pregnant patients. Here, we address whether circulating tumor cells have a metastatic advantage in the postpartum host and find the post-lactation rodent liver preferentially supports metastasis. Upon weaning, we observed liver weight loss, hepatocyte apoptosis, ECM remodeling including deposition of collagen and tenascin-C, and myeloid cell influx, data consistent with weaning-induced liver involution and establishment of a pro-metastatic microenvironment. Using intracardiac and intraportal metastasis models, we observed increased liver metastasis in post-weaning Balb/c mice compared to nulliparous controls. Human relevance is suggested by a ~3-fold increase in liver metastasis in postpartum breast cancer patients (n=564) and by liver-specific tropism (n=117). In sum, our data reveal a previously unknown biology of the rodent liver, weaning-induced liver involution, which may provide insight into the increased liver metastasis and poor prognosis of women diagnosed with postpartum breast cancer. PMID:27974414
NSG Mice Provide a Better Spontaneous Model of Breast Cancer Metastasis than Athymic (Nude) Mice
Puchalapalli, Madhavi; Zeng, Xianke; Mu, Liang; Anderson, Aubree; Hix Glickman, Laura; Zhang, Ming; Sayyad, Megan R.; Mosticone Wangensteen, Sierra; Clevenger, Charles V.; Koblinski, Jennifer E.
2016-01-01
Metastasis is the most common cause of mortality in breast cancer patients worldwide. To identify improved mouse models for breast cancer growth and spontaneous metastasis, we examined growth and metastasis of both estrogen receptor positive (T47D) and negative (MDA-MB-231, SUM1315, and CN34BrM) human breast cancer cells in nude and NSG mice. Both primary tumor growth and spontaneous metastases were increased in NSG mice compared to nude mice. In addition, a pattern of metastasis similar to that observed in human breast cancer patients (metastases to the lungs, liver, bones, brain, and lymph nodes) was found in NSG mice. Furthermore, there was an increase in the metastatic burden in NSG compared to nude mice that were injected with MDA-MB-231 breast cancer cells in an intracardiac experimental metastasis model. This data demonstrates that NSG mice provide a better model for studying human breast cancer metastasis compared to the current nude mouse model. PMID:27662655
In Situ Optical Mapping of Voltage and Calcium in the Heart
Ewart, Paul; Ashley, Euan A.; Loew, Leslie M.; Kohl, Peter; Bollensdorff, Christian; Woods, Christopher E.
2012-01-01
Electroanatomic mapping the interrelation of intracardiac electrical activation with anatomic locations has become an important tool for clinical assessment of complex arrhythmias. Optical mapping of cardiac electrophysiology combines high spatiotemporal resolution of anatomy and physiological function with fast and simultaneous data acquisition. If applied to the clinical setting, this could improve both diagnostic potential and therapeutic efficacy of clinical arrhythmia interventions. The aim of this study was to explore this utility in vivo using a rat model. To this aim, we present a single-camera imaging and multiple light-emitting-diode illumination system that reduces economic and technical implementation hurdles to cardiac optical mapping. Combined with a red-shifted calcium dye and a new near-infrared voltage-sensitive dye, both suitable for use in blood-perfused tissue, we demonstrate the feasibility of in vivo multi-parametric imaging of the mammalian heart. Our approach combines recording of electrophysiologically-relevant parameters with observation of structural substrates and is adaptable, in principle, to trans-catheter percutaneous approaches. PMID:22876327
Hillman, Stanley S; Hedrick, Michael S; Kohl, Zachary F
2017-06-01
The recent study by Filogonio et al. (2017) suggested that net cardiac shunt patterns in two species of reptiles (Trachemys scripta and Crotalus durissus) were not significantly influenced by the vascular distensibilities of the systemic and pulmonary vasculatures. This is in contrast to a previously published study (Hillman et al., 2014) in the toad (Rhinella marina) in which net cardiac shunts were predicted primarily by the physical properties of vascular distensibility rather than physiological control of resistance of the systemic and pulmonary vasculature. We analyze the data and conclusions reached by Filogonio et al. (2017) regarding the role of vascular distensibilities in determining net cardiac shunt patterns in reptiles in comparison with toads. In our view, the conclusions reached by Filogonio et al. (2017) are not supported by the data primarily because vascular distensibilities were not measured in the reptiles analyzed in their study. Copyright © 2017 Elsevier GmbH. All rights reserved.
Santiago, Justo; Acuña, Manuel; Arispe, Elizabeth; Camargo, Ronaldo; Neves, Juliana; Arnoni, Daniel; Fontes, Valmir F; Pedra, Carlos A
2007-03-01
The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the defects using Amplatzer devices. In two patients, although angiography demonstrated the presence of type-A patent ductus arteriosus, it was not possible to determine the minimum diameter accurately and it was necessary to measure it using a sizing balloon. An Amplatzer duct occluder was used in two patients and an Amplatzer muscular ventricular septal defect occluder, in the other. In all patients, full closure was confirmed in the catheterization laboratory and the patients were discharged on the same day with no complications. Percutaneous closure of a right patent ductus arteriosus associated with a right aortic arch is feasible, safe and effective.
Single Center Experience with the AngioVac Aspiration System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salsamendi, Jason, E-mail: jsalsamendi@med.miami.edu; Doshi, Mehul, E-mail: mdoshi@med.miami.edu; Bhatia, Shivank, E-mail: sbhatia1@med.miami.edu
2015-08-15
PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and themore » patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.« less
Accuracy Considerations in Image-guided Cardiac Interventions: Experience and Lessons Learned
Linte, Cristian A.; Lang, Pencilla; Rettmann, Maryam E.; Cho, Daniel S.; Holmes, David R.; Robb, Richard A.; Peters, Terry M.
2014-01-01
Motivation Medical imaging and its application in interventional guidance has revolutionized the development of minimally invasive surgical procedures leading to reduced patient trauma, fewer risks, and shorter recovery times. However, a frequently posed question with regards to an image guidance system is “how accurate is it?” On one hand, the accuracy challenge can be posed in terms of the tolerable clinical error associated with the procedure; on the other hand, accuracy is bound by the limitations of the system’s components, including modeling, patient registration, and surgical instrument tracking, all of which ultimately impact the overall targeting capabilities of the system. Methods While these processes are not unique to any interventional specialty, this paper discusses them in the context of two different cardiac image-guidance platforms: a model-enhanced ultrasound platform for intracardiac interventions and a prototype system for advanced visualization in image-guided cardiac ablation therapy. Results Pre-operative modeling techniques involving manual, semi-automatic and registration-based segmentation are discussed. The performance and limitations of clinically feasible approaches for patient registration evaluated both in the laboratory and operating room are presented. Our experience with two different magnetic tracking systems for instrument and ultrasound transducer localization is reported. Ultimately, the overall accuracy of the systems is discussed based on both in vitro and preliminary in vivo experience. Conclusion While clinical accuracy is specific to a particular patient and procedure and vastly dependent on the surgeon’s experience, the system’s engineering limitations are critical to determine whether the clinical requirements can be met. PMID:21671097
All-optical pulse-echo ultrasound probe for intravascular imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
Colchester, Richard J.; Noimark, Sacha; Mosse, Charles A.; Zhang, Edward Z.; Beard, Paul C.; Parkin, Ivan P.; Papakonstantinou, Ioannis; Desjardins, Adrien E.
2016-02-01
High frequency ultrasound probes such as intravascular ultrasound (IVUS) and intracardiac echocardiography (ICE) catheters can be invaluable for guiding minimally invasive medical procedures in cardiology such as coronary stent placement and ablation. With current-generation ultrasound probes, ultrasound is generated and received electrically. The complexities involved with fabricating these electrical probes can result in high costs that limit their clinical applicability. Additionally, it can be challenging to achieve wide transmission bandwidths and adequate wideband reception sensitivity with small piezoelectric elements. Optical methods for transmitting and receiving ultrasound are emerging as alternatives to their electrical counterparts. They offer several distinguishing advantages, including the potential to generate and detect the broadband ultrasound fields (tens of MHz) required for high resolution imaging. In this study, we developed a miniature, side-looking, pulse-echo ultrasound probe for intravascular imaging, with fibre-optic transmission and reception. The axial resolution was better than 70 microns, and the imaging depth in tissue was greater than 1 cm. Ultrasound transmission was performed by photoacoustic excitation of a carbon nanotube/polydimethylsiloxane composite material; ultrasound reception, with a fibre-optic Fabry-Perot cavity. Ex vivo tissue studies, which included healthy swine tissue and diseased human tissue, demonstrated the strong potential of this technique. To our knowledge, this is the first study to achieve an all-optical pulse-echo ultrasound probe for intravascular imaging. The potential for performing all-optical B-mode imaging (2D and 3D) with virtual arrays of transmit/receive elements, and hybrid imaging with pulse-echo ultrasound and photoacoustic sensing are discussed.
Cevik, Ozge Selin; Sahin, Leyla; Tamer, Lulufer
2018-05-01
The type and duration of exposure to stress is an important influence on emotional and cognitive functions. Learning is the adaptive response of the central nervous system that occurs in hippocampus which affects from environmental factors like exercise. In this study, we investigated effects of long term treadmill exercise on learning and behavior on chronic social isolated rat. Male Wistar rats (n = 32) randomly assigned into four groups: control, exercised, social isolation, social isolation + exercise during postnatal days (PNDs) 21-34. Social isolation protocol was applied during 14 days by placing rat in a cage one by one. Rats were exercised during 5 days, days were chosen randomly for overall 4 weeks (20, 30, 50, 60 min respectively). Finally, learning performance was evaluated by Morris water maze (MWM). Anxiety behavior was evaluated by Open field and elevated plus maze test. At the end of learning and behavior tests, the rats were decapitated to collect blood samples via intracardiac puncture and corticosterone analysis was performed with ELISA method. Animal weights and water consumption did not change significantly but food intake differed among groups. Corticosterone level did not change between groups. The frequency of entering to the target quadrant increased in exercised rat significantly. However, there was no difference in learning and memory in rats. Treadmill exercise reduced anxiety behavior significantly. Taken together these findings may point out that, long term treadmill exercise did not change learning and memory but reduced anxiety level of rat without changing corticosterone level. Copyright © 2018 Elsevier Inc. All rights reserved.
Focused Cardiac Ultrasound Using a Pocket-Size Device in the Emergency Room
Mancuso, Frederico José Neves; Siqueira, Vicente Nicoliello; Moisés, Valdir Ambrósio; Gois, Aécio Flavio Teixeira; de Paola, Angelo Amato Vincenzo; Carvalho, Antonio Carlos Camargo; Campos, Orlando
2014-01-01
Background Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions. Objective To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care. Methods One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated. Results The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection. Conclusion The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy. PMID:25590933
Transapical endovascular implantation of neochordae using a suction and suture device.
Maisano, Francesco; Michev, Iassen; Rowe, Stanton; Addis, Alessandro; Campagnol, Marino; Guidotti, Andrea; Colombo, Antonio; Alfieri, Ottavio
2009-07-01
Neochordae implantation is a standard method for treatment of mitral valve prolapse. We describe a transcatheter technology enabling transapical endovascular chordal implantation. Six adult pigs were anesthetized. Two 10F sheaths were introduced in the femoral vessels for monitoring and intracardiac echo. After midline sternotomy, the pericardium was opened, the apex was punctured inside two 2-0 polypropylene purse strings. A 0.035 in J tipped guidewire was introduced in the left ventricle and an ultra stiff 14F sheath (guide catheter) inserted through the apex. A suction-and-suture device was introduced in the left ventricle. The mitral valve was crossed under echo guidance. Using suction, either the anterior (two cases) or posterior (four cases) leaflet was captured and a loop of 4-0 polypropylene was thrown at the edge of the leaflet. The loop, with a pledget, was exteriorized through the introducer. The introducer was removed and the purse-string tied. Under echo guidance, the neochordae suture was pulled and tied over a pledget to evoke leaflet tethering. The animals were sacrificed and gross anatomy reviewed. Leaflet capture was feasible in the intended location in all cases. Following suture tethering, variable degrees of MR were obtained. At gross anatomy, the neochordae were positioned at 1-4mm from the leaflet free edge, and were firmly attached to the leaflets. Transcatheter endovascular neochordae implantation is feasible. A prolapse model is needed to further demonstrate feasibility under pathologic conditions. The apical approach allows easy and direct route to transcatheter beating heart minimally invasive mitral repair.
Pasipoularides, Ares
2015-01-01
Epigenetic mechanisms are fundamental in cardiac adaptations, remodeling, reverse remodeling, and disease. This 2-article series proposes that variable forces associated with diastolic RV/LV rotatory intraventricular flows can exert physiologically and clinically important, albeit still unappreciated, epigenetic actions influencing functional and morphological cardiac adaptations and/or maladaptations. Taken in-toto, the 2-part survey formulates a new paradigm in which intraventricular diastolic filling vortex-associated forces play a fundamental epigenetic role, and examines how heart cells react to these forces. The objective is to provide a perspective on vortical epigenetic effects, to introduce emerging ideas and suggest directions of multidisciplinary translational research. The main goal is to make pertinent biophysics and cytomechanical dynamic systems concepts accessible to interested translational and clinical cardiologists. I recognize that the diversity of the epigenetic problems can give rise to a diversity of approaches and multifaceted specialized research undertakings. Specificity may dominate the picture. However, I take a contrasting approach. Are there concepts that are central enough that they should be developed in some detail? Broadness competes with specificity. Would however this viewpoint allow for a more encompassing view that may otherwise be lost by generation of fragmented results? Part 1 serves as a general introduction, focusing on background concepts, on intracardiac vortex imaging methods, and on diastolic filling vortex-associated forces acting epigenetically on RV/LV endocardium and myocardium. Part 2 will describe pertinent available pluridisciplinary knowledge/research relating to mechanotransduction mechanisms for intraventricular diastolic vortex forces and myocardial deformations and to their epigenetic actions on myocardial and ventricular function and adaptations. PMID:25624114
Utility of a super-flexible three-dimensional printed heart model in congenital heart surgery.
Hoashi, Takaya; Ichikawa, Hajime; Nakata, Tomohiro; Shimada, Masatoshi; Ozawa, Hideto; Higashida, Akihiko; Kurosaki, Kenichi; Kanzaki, Suzu; Shiraishi, Isao
2018-05-28
The objective of this study was to assess the utility of 3D printed heart models of congenital heart disease for preoperative surgical simulation. Twenty patient-specific 3D models were created between March 2015 and August 2017. All operations were performed by a young consultant surgeon who had no prior experience with complex biventricular repair. All 15 patients with balanced ventricles had outflow tract malformations (double-outlet right ventricle in 7 patients, congenitally corrected transposition of great arteries in 5, transposition of great arteries in 1, interrupted aortic arch Type B in 1, tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries in 1). One patient had hypoplastic left heart complex, and the remaining 4 patients had a functional single ventricle. The median age at operation was 1.4 (range 0.1-5.9) years. Based on a multislice computed tomography data set, the 3D models were made of polyurethane resins using stereolithography as the printing technology and vacuum casting as the manufacturing method. All but 4 patients with a functional single ventricle underwent complete biventricular repair. The median cardiopulmonary bypass time and aortic cross-clamp time were 345 (110-570) min and 114 (35-293) min, respectively. During the median follow-up period of 1.3 (0.1-2.5) years, no mortality was observed. None of the patients experienced surgical heart block or systemic ventricular outflow tract obstruction. Three-dimensional printed heart models showed potential utility, especially in understanding the relationship between intraventricular communications and great vessels, as well as in simulation for creating intracardiac pathways.
Cardiac myxoma: diagnostic approach, surgical treatment and follow-up. A twenty years experience.
Jelic, J; Milicić, D; Alfirević, I; Anić, D; Baudoin, Z; Bulat, C; Corić, V; Dadić, D; Husar, J; Ivanćan, V; Korda, Z; Letica, D; Predrijevac, M; Ugljen, R; Vućemilo, I
1996-12-01
At the University Department of Cardiovascular Surgery in Zagreb, Croatia, we treated 81 patients with primary intracardiac myxoma, in a period from January 1975 to December 1994. There were 55 female and 26 male pts, in age from 1 month to 80 years, mean 46+/-15 years. Clinical manifestations varied from no symptoms and very poor or no clinical signs to various manifestations of chronic or acute congestive heart failure, syncope and arrhythmias with or without systemic findings such as high erythrocyte sedimentation rate, anaemia, leucocytosis, elevated gamma globulin, thrombocytopenia or low grade fever, as well as cerebrovascular accidents due to tumour embolization. Cardiac symptoms were predominant in 54 pts (66.6%) and cerebrovascular in 20 pts (24.7%). Seven pts (8.6%) were symptomless and discovered accidentally, mostly regarding on an unexplained heart murmur. In almost all the patients preoperative diagnosis of intracardiac myxoma was sufficiently established by echocardiography. The tumour was located in the left atrium in 62 pts (76.5%) and in the right atrium in 19 pts (23.5%). Delay from the onset of symptoms to the diagnosis was 6 months in average (range 10 days to 25 months). The average waiting for the operation was 9 days (range from 1 to 60 days). The echocardiographic diagnosis was confirmed during intraoperative examination followed by histological analysis. All pts underwent excision of myxoma using cardiopulmonary bypass with core and topical hypothermia and cold crystaloid cardioplegia. According to the additional preoperative and intraoperative findings, in 6 pts sinchronous mitral valve reconstruction, in 3 pts artificial mitral valve implantation and in 2 pts atrial wall reconstruction was performed. There was no perioperative mortality. After the operation, we could not evaluate all the patients long enough, mostly because of some paramedical circumstancies, such as war, migrations, etc. Twenty two pts undevent evaluation for at least 5 years after the operation. Among them there was no evidence of the tumour recurrence, 15 pts were asymptomatic and 7 had NYHA II class symptoms. For 17 pts with a left atrial myxoma preoperative and postoperative echocardiographic data were available for comparison, showing a significant reduction of the left atrial diameter (p<0.001) during the postoperative follow-up. Our data, presenting one of the biggest reports concerning cardiac myxomas, showed a broad spectrum of their clinical presentation, importance of echocardiography in diagnosing and postoperative follow-up and efficacy of a proper surgical intervention as a definite, curative therapy since there were no deaths and no significant cardiac dysfunction neither tumour reccurrence as well.
Transcatheter umbrella closure of valvular and paravalvular leaks.
Hourihan, M; Perry, S B; Mandell, V S; Keane, J F; Rome, J J; Bittl, J A; Lock, J E
1992-11-15
Our aim was to adapt the technique of transcatheter umbrella closure of intracardiac defects for closure of valvular and paravalvular defects. The double-umbrella device developed by Rashkind and Cuaso has been safely and effectively delivered across a host of intracardiac defects, but transcatheter closure of valvular and paravalvular leaks has not been reported. Between February 1987 and September 1990, eight patients who were believed to be poor operative candidates were taken to the catheterization laboratory for transcatheter double-umbrella closure of a valvular or a paravalvular leak. Four patients had a paravalvular leak around a prosthetic aortic valve. The other four patients had a valvular leak: one patient with a regurgitant native aortic valve after a Stansel procedure and three patients with a regurgitant porcine valve in a left ventricular apex to descending aorta conduit. Placement of a double-umbrella device was attempted in seven of the eight patients and was successful in all seven. Device placement was not attempted in one patient because of the crescentic shape of his defect. Two patients required two devices for each closure; the other five required only one device each. Angiography, performed on six patients after device closure, demonstrated that three patients had a completely occluded defect, two had trivial residual flow and one patient had mild residual flow through the device. All significant complications occurred in one patient who had hemolysis and oliguria that resolved when the initial umbrella was replaced by a larger device. In addition, two devices migrated to the patient's pulmonary arteries but were retrieved in the catheterization laboratory without difficulty. No other early or late complications occurred in 21 to 50 months of follow-up. Of the four patients with a paravalvular leak, the one who did not receive a device died at operation, one patient died at operation for an associated defect (in the operating room the umbrella was found securely in place across the paraaortic defect) and two patients are clinically well at home after 21 and 32 months, respectively. Of the four patients with closure of a valvular leak, one patient remains well at home 50 months later, one patient died at operation for associated defects and two patients had additional successful surgical treatment and remain well 29 months after device placement. Transcatheter umbrella closure appears to be a reasonable alternative for closure of a valvular or paravalvular leak in patients who are poor operative candidates.
Schmid, Isabelle; Didier, Dominique; Pfammatter, Thomas; Garachemani, Ali; Fleisch, Martin; Kirchin, Miles A; Meier, Bernhard
2007-06-12
To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.
Ganji, Yusof; Janabi-Sharifi, Farrokh; Cheema, Asim N
2011-12-01
Despite the recent advances in catheter design and technology, intra-cardiac navigation during electrophysiology procedures remains challenging. Incorporation of imaging along with magnetic or robotic guidance may improve navigation accuracy and procedural safety. In the present study, the in vivo performance of a novel remote controlled Robot Assisted Cardiac Navigation System (RACN) was evaluated in a porcine model. The navigation catheter and target sensor were advanced to the right atrium using fluoroscopic and intra-cardiac echo guidance. The target sensor was positioned at three target locations in the right atrium (RA) and the navigation task was completed by an experienced physician using both manual and RACN guidance. The navigation time, final distance between the catheter tip and target sensor, and variability in final catheter tip position were determined and compared for manual and RACN guided navigation. The experiments were completed in three animals and five measurements recorded for each target location. The mean distance (mm) between catheter tip and target sensor at the end of the navigation task was significantly less using RACN guidance compared with manual navigation (5.02 ± 0.31 vs. 9.66 ± 2.88, p = 0.050 for high RA, 9.19 ± 1.13 vs. 13.0 ± 1.00, p = 0.011 for low RA and 6.77 ± 0.59 vs. 15.66 ± 2.51, p = 0.003 for tricuspid valve annulus). The average time (s) needed to complete the navigation task was significantly longer by RACN guided navigation compared with manual navigation (43.31 ± 18.19 vs. 13.54 ± 1.36, p = 0.047 for high RA, 43.71 ± 11.93 vs. 22.71 ± 3.79, p = 0.043 for low RA and 37.84 ± 3.71 vs. 16.13 ± 4.92, p = 0.003 for tricuspid valve annulus. RACN guided navigation resulted in greater consistency in performance compared with manual navigation as evidenced by lower variability in final distance measurements (0.41 vs. 0.99 mm, p = 0.04). This study demonstrated the safety and feasibility of the RACN system for cardiac navigation. The results demonstrated that RACN performed comparably with manual navigation, with improved precision and consistency for targets located in and near the right atrial chamber. Copyright © 2011 John Wiley & Sons, Ltd.
Bun, Sok-Sithikun; Ayari, Anis; Latcu, Decebal Gabriel; Errahmouni, Abdelkarim; Saoudi, Nadir
2017-07-01
Remote magnetic navigation (RMN) and contact force (CF) sensing catheters are available technologies for radiofrequency (RF) catheter ablation of atrial fibrillation (AF). Our purpose was to compare time to electrogram (EGM) modification suggesting transmural lesions between RMN and CF-guided AF ablation. A total of 1,008 RF applications were analyzed in 21 patients undergoing RMN (n = 11) or CF-guided ablation (n = 10) for paroxysmal AF. All procedures were performed in sinus rhythm during general anesthesia. Time to EGM modification was measured until transmurality criteria were fulfilled: (1) complete disappearance of R if initial QR morphology; (2) diminution > 75% of R if initial QRS morphology; (3) complete disappearance of R' of initial RSR' morphology. Impedance drop as well as force time integral (FTI) were also assessed for each application. Mean CF at the beginning of each RF application in the CF group was 11 ± 2 g and mean FTI per application was 488 ± 163 gs. Time to EGM modification was significantly shorter in the RMN group (4.52 ± 0.1 seconds vs. 5.6 ± 0.09 seconds; P < 0.00001). There was no significant difference between other procedural parameters. Remote magnetic AF ablation is associated with faster EGM modification suggesting transmurality than optimized CF and FTI-guided catheter ablation. © 2017 Wiley Periodicals, Inc.
Taccardi, B; Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S
1987-01-01
An olive-shaped probe (25 X 12 mm) with 41 evenly distributed recording electrodes on its surface was introduced into the left ventricles of seven open-chest dogs via the left atrium. In two other dogs a cylindrical probe (40 X 3 mm) was used. Electrical stimuli were delivered at 66 endocardial, midwall, or epicardial sites in the left and right ventricular walls and the septum. Mechanical stimuli were also applied at various epicardial sites. On-line mapping of equipotential contour lines on the surface of the probe invariably revealed a clear-cut potential minimum on the electrode that faced the pacing site. Time of appearance of potential minimum was 3 to 5 msec after endocardial stimuli, 10 to 25 msec for midwall and epicardial pacing, and 30 msec or more for right ventricular stimulation. Simultaneous stimulation at two sites 1.2 cm apart gave rise to two separate minima on the maps. "Pseudoisochrones" derived from electrograms recorded by the new probe were slightly less accurate in indicating the site of origin of extrasystoles. We conclude that equipotential and "isochrone" contour maps recorded from an array of semidirect electrodes, regularly distributed on the surface of an intraventricular probe, provide information on the site of origin (location and intramural depth) of ectopic paced beats in a normal dog heart.
Hayat, Sajad A; Kojodjojo, Pipin; Mason, Anthony; Benfield, Ann; Wright, Ian; Whinnett, Zachary; Lim, Phang Boon; Davies, D Wyn; Lefroy, David; Peters, Nicholas S; Kanagaratnam, Prapa
2013-03-01
Implantable cardioverter defibrillator (ICD) implantation has increased significantly over the last 10 years. Concerns about the safety and reliability of ICD systems have been raised, with premature lead failure and battery malfunctions accounting for the majority of reported adverse events. We describe the unique mode of presentation, diagnosis, and management of cardiac resynchronization therapy defibrillators (CRT-D) malfunctions that were caused by weakened bonding between the generator and header. Between June 2008 and December 2009, 22 Teligen™ ICDs and 24 Cognis™ CRT-Ds were implanted subpectorally at our institution, until a product advisory was issued. Of 24 Cognis™ CRT-D implants, 3 patients presented with CRT-D malfunctions. All our cases presented with initially intermittent and then persisting increases in shock lead impedance, associated with nonphysiological noise in the shock electrogram channels. These issues were rectified by generator change. Postexplant laboratory analysis confirmed inadequate bonding between device header and titanium casing in all cases, resulting in loosening and rocking of the header followed by fatigue-induced fracture of the shock circuitry. Weakened bonding between the header and generator casing of subpectorally implanted CRT-Ds can result in fractures and malfunction of the HV circuit. Physicians monitoring patients with devices affected by the product advisory should remain vigilant in order to diagnose and manage similar device malfunction expediently. © 2012 Wiley Periodicals, Inc.
Vulnerability to ventricular fibrillation
NASA Astrophysics Data System (ADS)
Janse, Michiel J.
1998-03-01
One of the factors that favors the development of ventricular fibrillation is an increase in the dispersion of refractoriness. Experiments will be described in which an increase in dispersion in the recovery of excitability was determined during brief episodes of enhanced sympathetic nerve activity, known to increase the risk of fibrillation. Whereas in the normal heart ventricular fibrillation can be induced by a strong electrical shock, a premature stimulus of moderate intensity only induces fibrillation in the presence of regional ischemia, which greatly increases the dispersion of refractoriness. One factor that is of importance for the transition of reentrant ventricular tachycardia to ventricular fibrillation during acute regional ischemia is the subendocardial Purkinje system. After selective destruction of the Purkinje network by lugol, reentrant tachycardias still develop in the ischemic region, but they do not degenerate into fibrillation. Finally, attempts were made to determine the minimal mass of thin ventricular myocardium required to sustain fibrillation induced by burst pacing. This was done by freezing of subendocardial and midmural layers. The rim of surviving epicardial muscle had to be larger than 20 g. Extracellular electrograms during fibrillation in both the intact and the "frozen" left ventricle were indistinguishable, but activation patterns were markedly different. In the intact ventricle epicardial activation was compatible with multiple wavelet reentry, in the "frozen" heart a single, or at most two wandering reentrant waves were seen.
Lei, Bei; Cao, Jie; Shen, Jie; Zhao, Lanxiang; Liang, Sheng; Meng, Qinggang; Xie, Wenhui; Yang, Shunfang
2013-08-20
Lung cancer is the leading cause of cancer-related death in men and women. It is also the most common cause of brain metastases. A brain metastasis model is difficult to be established because of the presence of the blood-brain barrier (BBB) and the lack of optimal methods for detecting brain metastasis in nude mice. Thus, the establishment of a Chinese lung adenocarcinoma cell line and its animal model with brain metastasis potency and in vivo research is of great significance. CPA-Yang1 cells were obtained from a patient with human lung adenocarcinoma by lentiviral vector-mediated transfection of green fluorescence protein. Intracardiac inoculation of the cells was performed in nude mice, and brain metastatic lesions were detected using micro ¹⁸F FDG-PET/CT scanners, small animal in vivo imaging system for fluorescence, radionuclide and X ray fused imaging, magnetic resonance imaging (MRI) with sense body detection, and resection. The samples were divided into two parts for cell culture and histological diagnosis. The process was repeated in vivo and in vitro for four cycles to obtain a novel cell clone, CPA-Yang1-BR. A novel cell clone, CPA-Yang1-BR, was obtained with a brain metastatic rate of 50%. The use of MRI for the detection of brain metastases has obvious advantages. An experimental Chinese lung adenocarcinoma cell clone (CPA-Yang1-BR) and its animal model with brain metastasis potency in nude mice were established. MRI with sense body or micro MRI may be used as a sensitive, accurate, and noninvasive method to detect experimental brain metastases in intact live immunodeficient mice. The results of this study may serve as a technical platform for brain metastases from lung adenocarcinoma.
Monitoring tumor metastases and osteolytic lesions with bioluminescence and micro CT imaging.
Lim, Ed; Modi, Kshitij; Christensen, Anna; Meganck, Jeff; Oldfield, Stephen; Zhang, Ning
2011-04-14
Following intracardiac delivery of MDA-MB-231-luc-D3H2LN cells to Nu/Nu mice, systemic metastases developed in the injected animals. Bioluminescence imaging using IVIS Spectrum was employed to monitor the distribution and development of the tumor cells following the delivery procedure including DLIT reconstruction to measure the tumor signal and its location. Development of metastatic lesions to the bone tissues triggers osteolytic activity and lesions to tibia and femur were evaluated longitudinally using micro CT. Imaging was performed using a Quantum FX micro CT system with fast imaging and low X-ray dose. The low radiation dose allows multiple imaging sessions to be performed with a cumulative X-ray dosage far below LD50. A mouse imaging shuttle device was used to sequentially image the mice with both IVIS Spectrum and Quantum FX achieving accurate animal positioning in both the bioluminescence and CT images. The optical and CT data sets were co-registered in 3-dimentions using the Living Image 4.1 software. This multi-mode approach allows close monitoring of tumor growth and development simultaneously with osteolytic activity.
Nieschlag, Eberhard; Vorona, Elena
2015-09-01
Since the 1970s anabolic androgenic steroids (AAS) have been abused at ever increasing rates in competitive athletics, in recreational sports and in bodybuilding. Exceedingly high doses are often consumed over long periods, in particular by bodybuilders, causing acute or chronic adverse side effects frequently complicated by additional polypharmacy. This review summarizes side effects on non-reproductive organs and functions; effects on male and female reproduction have been recently reviewed in a parallel paper. Among the most striking AAS side effects are increases in haematocrit and coagulation causing thromboembolism, intracardiac thrombosis and stroke as well as other cardiac disturbances including arrhythmias, cardiomyopathies and possibly sudden death. 17α-alkylated AAS are liver toxic leading to cholestasis, peliosis, adenomas and carcinomas. Hyperbilirubinaemia can cause cholemic nephrosis and kidney failure. AAS abuse may induce exaggerated self-confidence, reckless behavior, aggressiveness and psychotic symptoms. AAS withdrawal may be accompanied by depression and suicidal intentions. Since AAS abuse is not or only reluctantly admitted physicians should be aware of the multitude of serious side effects when confronted with unclear symptoms.
Marulasiddappa, Vinay; Raghavavendra, B S
2015-07-01
Children with uncorrected cyanotic congenital heart diseases can present for non cardiac surgeries. They pose several challenges to the Anaesthesiologist, especially when they are posted for emergency surgery, due to the complex haemodynamic changes secondary to the heart disease. Pentalogy of Fallot (POF) is a rare form of congenital heart disease characterized by the association of Tetralogy of Fallot (TOF) with an atrial septal defect (ASD). TOF is the leading cause of intracardiac right to left shunt and is the commonest type of cyanotic congenital heart disease to cause a brain abscess. Children with POF presenting with brain abscess pose several challenges to the anaesthesiologist due to the altered haemodynamics and warrant a meticulous anaesthetic plan. There are very few case reports of Anaesthesia management of a child with Pentalogy of Fallot (POF) presenting for non cardiac surgery. We report the anaesthetic management of a rare case of a 5-year-old child with uncorrected POF, who presented to our Superspeciality hospital with a brain abscess and underwent an emergency craniotomy with drainage of the brain abscess successfully.
Behçet syndrome: the vascular cluster.
Yazıcı, Hasan; Seyahi, Emire
2016-11-17
Although skin-mucosa lesions are common in almost all patients with Behçet syndrome (BS), clinical properties may differ from one patient to another. Within BS, there are subsets with different organ involvement and hence probably different pathological pathways. These subsets can be described as a) solo skin-mucosa disease with no major organ involvement, b) eye disease, c) seronegative spondyloarthropathy-like disease (arthritis, enthesopathy, and folliculitis), d) Crohn-like disease, and finally the topic of this chapter: e) vascular disease. In the vascular disease subset, not surprisingly, several types of vascular involvement may be observed in the same individual. These subsets may make up the total clinical picture all at the same time or step by step with each relapse. Significant correlations exist between cerebral vascular thrombosis and pulmonary artery involvement, intracardiac thrombi and pulmonary artery involvement, Budd-Chiari syndrome, and inferior vena cava syndrome. Lower extremity vein thrombosis is often present in these associations and even precedes them. The recognition of these clusters is not only important in diagnosis and management but also in basic science, including genetic studies.
Heart Transplantation in Congenital Heart Disease: In Whom to Consider and When?
Attenhofer Jost, Christine H.; Schmidt, Dörthe; Huebler, Michael; Balmer, Christian; Noll, Georg; Caduff, Rosmarie; Greutmann, Matthias
2013-01-01
Due to impressive improvements in surgical repair options, even patients with complex congenital heart disease (CHD) may survive into adulthood and have a high risk of end-stage heart failure. Thus, the number of patients with CHD needing heart transplantation (HTx) has been increasing in the last decades. This paper summarizes the changing etiology of causes of death in heart failure in CHD. The main reasons, contraindications, and risks of heart transplantation in CHD are discussed and underlined with three case vignettes. Compared to HTx in acquired heart disease, HTx in CHD has an increased risk of perioperative death and rejection. However, outcome of HTx for complex CHD has improved over the past 20 years. Additionally, mechanical support options might decrease the waiting list mortality in the future. The number of patients needing heart-lung transplantation (especially for Eisenmenger's syndrome) has decreased in the last years. Lung transplantation with intracardiac repair of a cardiac defect is another possibility especially for patients with interatrial shunts. Overall, HTx will remain an important treatment option for CHD in the near future. PMID:23577237
⁶⁸Ga-DOTA-TOC-PET/CT detects heart metastases from ileal neuroendocrine tumors.
Calissendorff, Jan; Sundin, Anders; Falhammar, Henrik
2014-09-01
Metastases from ileal neuroendocrine tumors (NETs) to the myocardium are rare and generally seen in patients with widespread metastatic NET disease. The objectives of this investigation were to describe the frequency of intracardiac metastases in ileal NET patients examined by (68)Ga-DOTA-TOC-PET/CT and to describe the cases in detail. All (68)Ga-DOTA-TOC-PET/CT examinations performed at the Karolinska University Hospital since 2010 until April 2012 were reviewed. In all, 128 out of 337 examinations were in patients with ileal NETs. Four patients had seven myocardiac metastases, yielding a frequency of 4.3 % in patients with ileal NETs. One patient had cardiac surgery while three were treated with somatostatin analogs. The cardiac metastases did not affect the patients' activity of daily life. (68)Ga-DOTA-TOC-PET/CT is an established imaging modality in identifying cardiac metastases in ileal NETs. Prospective studies are needed to confirm the true clinical value of (68)Ga-DOTA-TOC-PET/CT in detecting cardiac metastases in both ileal and non-ileal NETs.
18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.
Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S
2017-02-01
This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.
Minimally invasive paediatric cardiac surgery.
Bacha, Emile; Kalfa, David
2014-01-01
The concept of minimally invasive surgery for congenital heart disease in paediatric patients is broad, and has the aim of reducing the trauma of the operation at each stage of management. Firstly, in the operating room using minimally invasive incisions, video-assisted thoracoscopic and robotically assisted surgery, hybrid procedures, image-guided intracardiac surgery, and minimally invasive cardiopulmonary bypass strategies. Secondly, in the intensive-care unit with neuroprotection and 'fast-tracking' strategies that involve early extubation, early hospital discharge, and less exposure to transfused blood products. Thirdly, during postoperative mid-term and long-term follow-up by providing the children and their families with adequate support after hospital discharge. Improvement of these strategies relies on the development of new devices, real-time multimodality imaging, aids to instrument navigation, miniaturized and specialized instrumentation, robotic technology, and computer-assisted modelling of flow dynamics and tissue mechanics. In addition, dedicated multidisciplinary co-ordinated teams involving congenital cardiac surgeons, perfusionists, intensivists, anaesthesiologists, cardiologists, nurses, psychologists, and counsellors are needed before, during, and after surgery to go beyond apparent technological and medical limitations with the goal to 'treat more while hurting less'.