  1. Integrated metabolomic analysis of the nano-sized copper particle-induced hepatotoxicity and nephrotoxicity in rats: A rapid invivo screening method for nanotoxicity

    SciTech Connect

    Lei Ronghui; Department of Public Health, Xi'an Jiaotong University, Xi'an 710061; Wu Chunqi

    2008-10-15

    lipidosis induced by nano-copper. The data generated from the current study completely supports the fact that an integrated metabolomic approach is promising for the development of a rapid invivo screening method for nanotoxicity.« less

  2. Methods of in-vivo mouse lung micro-CT

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Nixon, Earl; Thiesse, Jacqueline; McLennan, Geoffrey; Ross, Alan; Hoffman, Eric

    2005-04-01

    Micro-CT will have a profound influence on the accumulation of anatomical and physiological phenotypic changes in natural and transgenetic mouse models. Longitudinal studies will be greatly facilitated, allowing for a more complete and accurate description of events if in-vivo studies are accomplished. The purpose of the ongoing project is to establish a feasible and reproducible setup for in-vivo mouse lung micro-computed tomography (μCT). We seek to use in-vivo respiratory-gated μCT to follow mouse models of lung disease with subsequent recovery of the mouse. Methodologies for optimizing scanning parameters and gating for the in-vivo mouse lung are presented. A Scireq flexiVent ventilated the gas-anesthetized mice at 60 breaths/minute, 30 cm H20 PEEP, 30 ml/kg tidal volume and provided a respiratory signal to gate a Skyscan 1076 μCT. Physiologic monitoring allowed the control of vital functions and quality of anesthesia, e.g. via ECG monitoring. In contrary to longer exposure times with ex-vivo scans, scan times for in-vivo were reduced using 35μm pixel size, 158ms exposure time and 18μm pixel size, 316ms exposure time to reduce motion artifacts. Gating via spontaneous breathing was also tested. Optimal contrast resolution was achieved at 50kVp, 200μA, applying an aluminum filter (0.5mm). There were minimal non-cardiac related motion artifacts. Both 35μm and 1μm voxel size images were suitable for evaluation of the airway lumen and parenchymal density. Total scan times were 30 and 65 minutes respectively. The mice recovered following scanning protocols. In-vivo lung scanning with recovery of the mouse delivered reasonable image quality for longitudinal studies, e.g. mouse asthma models. After examining 10 mice, we conclude μCT is a feasible tool evaluating mouse models of lung pathology in longitudinal studies with increasing anatomic detail available for evaluation as one moves from in-vivo to ex-vivo studies. Further developments include automated

  3. Application of laser-induced autofluorescence spectra detection system in human colorectal cancer in-vivo screening

    NASA Astrophysics Data System (ADS)

    Chia, Teck Chee; Fu, Sheng; Chia, Yee Hong; Kwek, Leong Chuan; Tang, Choong Leong

    2005-09-01

    This study aimed at applying Laser induced-autofluorescence (LIAF) diagnostics method as an in-vivo screening of colorectal polyplcancer. The spectrum algorithm based on the ratio of autofluorescence intensity was used to identify the diseased tissues from the normal tissues as it was generally performed better than an algorithm based only simply on the intensity of the spectrum. Histopathological biopsy results were compared with the detected AF spectra characteristics for different kinds of polyps. 73 patients had been examined via the LIAF spectroscopy detection system during their colonoscopy screening in Endoscopy Center, Singapore General Hospital. The autofluorescence from the surface of the colorectal tissues under 405 nm laser light excitation was detected using our detecting system. In the experimental investigation two groups of patients were involved. One group was "abnormal" group. There were 25 patients belonging to this group since polyps or carcinoma was found in their colorectal tract during colonoscopy. The histopathology reports confirm the group classification. Total 36 polyps' AF spectra and 9 carcinoma' AF spectra were detected from 25 patients of the abnormal group during their regular endoscopy examination. The intensity ratios RI-680/I-500 and RI-630/I-500 of polyps/cancerous AF spectra and intensity ratios of corresponding normal colorectal AF spectra were calculated. Two critical intensity ratios for separating the AF intensity ratios RI-680/I-500 and RI-630/I-500 of normal and abnormal colorectal tissues were defined as 0.5 and 0.6 respectively. Using the critical intensity ratio values, 48 "normal" group patients' rectums were checked via the LIAF detection system. There were 20 patients (41.7%) whose AF spectra of colorectal tract mucosa belonging to abnormal spectra. However, these 20 patients had not been found under white light via traditional endoscopy. For small diseased area like small plat polyp disease and carcinoma, it was

  4. A Novel Method to Assess Wear Rates of Retrieved Tibial Inserts Following in-vivo Use

    NASA Astrophysics Data System (ADS)

    Paniogue, Tanille J.

    Ultra-high molecular weight polyethylene (UHMWPE) on cobalt chrome is the bearing couple of choice for total knee arthroplasty. The number of patients undergoing total knee arthroplasty has been steadily growing and is projected to continue increasing rapidly in the near future. Many of these patients are younger and more active and therefore need a longer lasting device. However, many of these devices fail prematurely and often the primary reason for failure and ultimately revision is due to wear related issues. Therefore, examining how wear rates of the UHMWPE tibial insert change during in-vivo use can help elucidate the mechanisms of accelerated wear and hopefully aid in finding solutions to combat wear related failures. Different crosslinking treatments have been employed by manufacturers to improve wear resistance of the polyethylene. While this has been shown to be an effective way to reduce wear, crosslinking has led to other issues such as oxidative instability and a decline in mechanical properties. The purpose of this body of work is to examine how changes in oxidation, after in-vivo use, affect wear resistance. A novel testing method was developed to test the native articular surface from retrieved tibial inserts in a laboratory Pin-on-Disk (POD) simulator. The method was validated using short-duration implant articular surfaces and non-articular control pins. In the absence of high surface oxidation or severe surface damage, the articular surface pins had comparable steady state wear rates to their bulk counterparts. Tests of devices with longer in-vivo service show chemical changes consistent with a free-radical mediated oxidation mechanism. Tribological assessment of the articular surfaces shows increasing wear rates as a function of oxidation. While this relationship has been hypothesized in the literature, these experiments represent the first physical demonstration of the phenomenon. The wear mechanism is further explored through infrared

  5. Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements

    SciTech Connect

    Bentefour, El H., E-mail: hassan.bentefour@iba-group.com; Prieels, Damien; Tang, Shikui

    Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification inmore » the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time

  6. Automation and uncertainty analysis of a method for in-vivo range verification in particle therapy.

    PubMed

    Frey, K; Unholtz, D; Bauer, J; Debus, J; Min, C H; Bortfeld, T; Paganetti, H; Parodi, K

    2014-10-07

    We introduce the automation of the range difference calculation deduced from particle-irradiation induced β(+)-activity distributions with the so-called most-likely-shift approach, and evaluate its reliability via the monitoring of algorithm- and patient-specific uncertainty factors. The calculation of the range deviation is based on the minimization of the absolute profile differences in the distal part of two activity depth profiles shifted against each other. Depending on the workflow of positron emission tomography (PET)-based range verification, the two profiles under evaluation can correspond to measured and simulated distributions, or only measured data from different treatment sessions. In comparison to previous work, the proposed approach includes an automated identification of the distal region of interest for each pair of PET depth profiles and under consideration of the planned dose distribution, resulting in the optimal shift distance. Moreover, it introduces an estimate of uncertainty associated to the identified shift, which is then used as weighting factor to 'red flag' problematic large range differences. Furthermore, additional patient-specific uncertainty factors are calculated using available computed tomography (CT) data to support the range analysis. The performance of the new method for in-vivo treatment verification in the clinical routine is investigated with in-room PET images for proton therapy as well as with offline PET images for proton and carbon ion therapy. The comparison between measured PET activity distributions and predictions obtained by Monte Carlo simulations or measurements from previous treatment fractions is performed. For this purpose, a total of 15 patient datasets were analyzed, which were acquired at Massachusetts General Hospital and Heidelberg Ion-Beam Therapy Center with in-room PET and offline PET/CT scanners, respectively. Calculated range differences between the compared activity distributions are reported in a

  7. Automation and uncertainty analysis of a method for in-vivo range verification in particle therapy

    NASA Astrophysics Data System (ADS)

    Frey, K.; Unholtz, D.; Bauer, J.; Debus, J.; Min, C. H.; Bortfeld, T.; Paganetti, H.; Parodi, K.

    2014-10-01

    We introduce the automation of the range difference calculation deduced from particle-irradiation induced β+-activity distributions with the so-called most-likely-shift approach, and evaluate its reliability via the monitoring of algorithm- and patient-specific uncertainty factors. The calculation of the range deviation is based on the minimization of the absolute profile differences in the distal part of two activity depth profiles shifted against each other. Depending on the workflow of positron emission tomography (PET)-based range verification, the two profiles under evaluation can correspond to measured and simulated distributions, or only measured data from different treatment sessions. In comparison to previous work, the proposed approach includes an automated identification of the distal region of interest for each pair of PET depth profiles and under consideration of the planned dose distribution, resulting in the optimal shift distance. Moreover, it introduces an estimate of uncertainty associated to the identified shift, which is then used as weighting factor to ‘red flag’ problematic large range differences. Furthermore, additional patient-specific uncertainty factors are calculated using available computed tomography (CT) data to support the range analysis. The performance of the new method for in-vivo treatment verification in the clinical routine is investigated with in-room PET images for proton therapy as well as with offline PET images for proton and carbon ion therapy. The comparison between measured PET activity distributions and predictions obtained by Monte Carlo simulations or measurements from previous treatment fractions is performed. For this purpose, a total of 15 patient datasets were analyzed, which were acquired at Massachusetts General Hospital and Heidelberg Ion-Beam Therapy Center with in-room PET and offline PET/CT scanners, respectively. Calculated range differences between the compared activity distributions are reported in

  8. Novel methods of time-resolved fluorescence data analysis for in-vivo tissue characterization: application to atherosclerosis.

    PubMed

    Jo, J A; Fang, Q; Papaioannou, T; Qiao, J H; Fishbein, M C; Dorafshar, A; Reil, T; Baker, D; Freischlag, J; Marcu, L

    2004-01-01

    This study investigates the ability of new analytical methods of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data to characterize tissue in-vivo, such as the composition of atherosclerotic vulnerable plaques. A total of 73 TR-LIFS measurements were taken in-vivo from the aorta of 8 rabbits, and subsequently analyzed using the Laguerre deconvolution technique. The investigated spots were classified as normal aorta, thin or thick lesions, and lesions rich in either collagen or macrophages/foam-cells. Different linear and nonlinear classification algorithms (linear discriminant analysis, stepwise linear discriminant analysis, principal component analysis, and feedforward neural networks) were developed using spectral and TR features (ratios of intensity values and Laguerre expansion coefficients, respectively). Normal intima and thin lesions were discriminated from thick lesions (sensitivity >90%, specificity 100%) using only spectral features. However, both spectral and time-resolved features were necessary to discriminate thick lesions rich in collagen from thick lesions rich in foam cells (sensitivity >85%, specificity >93%), and thin lesions rich in foam cells from normal aorta and thin lesions rich in collagen (sensitivity >85%, specificity >94%). Based on these findings, we believe that TR-LIFS information derived from the Laguerre expansion coefficients can provide a valuable additional dimension for in-vivo tissue characterization.

  9. Method for in-vivo synthetic aperture B-flow imaging

    NASA Astrophysics Data System (ADS)

    Jensen, Jorgen A.

    2004-04-01

    B-flow techniques introduced in commercial scanners have been useful is visualizing places of flow. The method is relatively independent of flow angle and can give a good perception of vessel location and turbulence. This paper introduces a technique for making a synthetic aperture B-flow system. Data is acquired over a number of pulse emissions, where a set of elements synthesizes a spherical wave and the received signal on all elements are acquired. The sequence is repeated and a full new image can always be formed from the last set of emissions, thus making the frame rate very high. The data is continuously available at all places in the image and any kind of echo canceling filter can therefore be used without the usual initialization problems. The B-flow images are then formed by displaying the gray level image after echo canceling. A fast moving scatterer will give a bright echo and slower moving scatterers will yield a dark echo. The approach is demonstrated through in-vivo images. A 128 elements 7 MHz probe with lambda pitch is used together with the RASMUS experimental scanner. Eleven elements are used per emission and the eight emissions are spread evenly over the 128 elements of the array. The signal received by the 64 elements closets to the emission are sampled at 40 MHz and 12 bits at a pulse repetition frequency of 3 kHz. A full second of data is acquired from a healthy 29 years old male volunteer from the carotid artery. The data is beamformed, combined, and echo canceled off-line. High-pass filters designed by the Remez exchange algorithm, have been used for the B-flow processing. The image is displayed after each set of emissions yielding 375 frames per second. Both the flow in the carotid artery and the jugular vein can be seen along with an indication of the acceleration and spatial variation of the velocity.

  10. Experimental method of in-vivo dosimetry without build-up device on the skin for external beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Jeon, Hosang; Nam, Jiho; Lee, Jayoung; Park, Dahl; Baek, Cheol-Ha; Kim, Wontaek; Ki, Yongkan; Kim, Dongwon

    2015-06-01

    Accurate dose delivery is crucial to the success of modern radiotherapy. To evaluate the dose actually delivered to patients, in-vivo dosimetry (IVD) is generally performed during radiotherapy to measure the entrance doses. In IVD, a build-up device should be placed on top of an in-vivo dosimeter to satisfy the electron equilibrium condition. However, a build-up device made of tissue-equivalent material or metal may perturb dose delivery to a patient, and requires an additional laborious and time-consuming process. We developed a novel IVD method using a look-up table of conversion ratios instead of a build-up device. We validated this method through a monte-carlo simulation and 31 clinical trials. The mean error of clinical IVD is 3.17% (standard deviation: 2.58%), which is comparable to that of conventional IVD methods. Moreover, the required time was greatly reduced so that the efficiency of IVD could be improved for both patients and therapists.

  11. Correlation Between An In-vitro Method And An In-vivo Method In Assessing Bioavailable Arsenic In Two Pesticide-Amended Soils

    NASA Astrophysics Data System (ADS)

    Quazi, S.; Sarkar, D.; Sylvia, V.; Datta, R.

    2006-05-01

    Health risk assessment of Arsenic (As) enriched soil requires the estimation of bioavailable fraction of total metal. Research has been conducted to gain a better understanding of the relationship between metal availability and risk assessment. Some baseline risk assessments developed for contaminated sites have used the conservative assumption that all (i.e. 100%) of the As present in soils and wastes is bioavailable, due to tremendous cost associated with in-vivo bioavailability studies. This potentially overestimates the actual health risk, elevating the expenses associated with site cleanup. Health risk from direct exposure to soil-As via the hand-to-mouth exposure route is restricted only to those fractions of As in the soil that are available to the human gastrointestinal system. A reasonable approach is to develop in-vitro methods that simulate the complex and dynamic human gastrointestinal system and correlate well with the results of in-vivo method. Thus this study aims in addressing the potential of one such in-vitro method developed by our research group in assessing the bioavailability of soil-As. Two soils with drastically different chemical characteristics in regards to As reactivity (Immokalee-low As retention capacity; Millhopper-high As retention capacity) spiked with a pesticide (sodium arsenate) were used. Soils were amended at two rates representing concentrations typically found at Superfund sites: 675 and 1500 mg/kg of As. In-vitro bioavailability experiments were performed in order to obtain an estimate of the amount of As likely to be available in the human gastrointestinal system as well as the fraction potentially absorbed onto the intestinal linings. Following the in-vitro study selective in-vivo bioavailability studies using As-contaminated soils were conducted on male and female mice to validate the in-vitro results via comparison with the in-vivo data. Soils were administered orally to the BALB/c mice immediately after spiking

  12. An Optical Method for the In-Vivo Characterization of the Biomechanical Response of the Right Ventricle.

    PubMed

    Soltani, A; Lahti, J; Järvelä, K; Curtze, S; Laurikka, J; Hokka, M; Kuokkala, V-T

    2018-05-01

    The intraoperative in-vivo mechanical function of the left ventricle has been studied thoroughly using echocardiography in the past. However, due to technical and anatomical issues, the ultrasound technology cannot easily be focused on the right side of the heart during open-heart surgery, and the function of the right ventricle during the intervention remains largely unexplored. We used optical imaging and digital image correlation for the characterization of the right ventricle motion and deformation during open-heart surgery. This work is a pilot study focusing on one patient only with the aim of establishing the framework for long term research. These experiments show that optical imaging and the analysis of the images can be used to obtain similar parameters, and partly at higher accuracy, for describing the mechanical functioning of the heart as the ultrasound technology. This work describes the optical imaging based method to characterize the mechanical response of the heart in-vivo, and offers new insight into the mechanical function of the right ventricle.

  13. Allergic sensitization: screening methods

    PubMed Central

    2014-01-01

    Experimental in silico, in vitro, and rodent models for screening and predicting protein sensitizing potential are discussed, including whether there is evidence of new sensitizations and allergies since the introduction of genetically modified crops in 1996, the importance of linear versus conformational epitopes, and protein families that become allergens. Some common challenges for predicting protein sensitization are addressed: (a) exposure routes; (b) frequency and dose of exposure; (c) dose-response relationships; (d) role of digestion, food processing, and the food matrix; (e) role of infection; (f) role of the gut microbiota; (g) influence of the structure and physicochemical properties of the protein; and (h) the genetic background and physiology of consumers. The consensus view is that sensitization screening models are not yet validated to definitively predict the de novo sensitizing potential of a novel protein. However, they would be extremely useful in the discovery and research phases of understanding the mechanisms of food allergy development, and may prove fruitful to provide information regarding potential allergenicity risk assessment of future products on a case by case basis. These data and findings were presented at a 2012 international symposium in Prague organized by the Protein Allergenicity Technical Committee of the International Life Sciences Institute’s Health and Environmental Sciences Institute. PMID:24739743

  14. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2002-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

  15. The interdependence between screening methods and screening libraries.

    PubMed

    Shelat, Anang A; Guy, R Kiplin

    2007-06-01

    The most common methods for discovery of chemical compounds capable of manipulating biological function involves some form of screening. The success of such screens is highly dependent on the chemical materials - commonly referred to as libraries - that are assayed. Classic methods for the design of screening libraries have depended on knowledge of target structure and relevant pharmacophores for target focus, and on simple count-based measures to assess other properties. The recent proliferation of two novel screening paradigms, structure-based screening and high-content screening, prompts a profound rethink about the ideal composition of small-molecule screening libraries. We suggest that currently utilized libraries are not optimal for addressing new targets by high-throughput screening, or complex phenotypes by high-content screening.

  16. An imaged-based inverse finite element method to determine in-vivo mechanical properties of the human trabecular meshwork.

    PubMed

    Pant, Anup D; Kagemann, Larry; Schuman, Joel S; Sigal, Ian A; Amini, Rouzbeh

    2017-01-01

    Previous studies have shown that the trabecular meshwork (TM) is mechanically stiffer in glaucomatous eyes as compared to normal eyes. It is believed that elevated TM stiffness increases resistance to the aqueous humor outflow, producing increased intraocular pressure (IOP). It would be advantageous to measure TM mechanical properties in vivo , as these properties are believed to play an important role in the pathophysiology of glaucoma and could be useful for identifying potential risk factors. The purpose of this study was to develop a method to estimate in-vivo TM mechanical properties using clinically available exams and computer simulations. Inverse finite element simulation. A finite element model of the TM was constructed from optical coherence tomography (OCT) images of a healthy volunteer before and during IOP elevation. An axisymmetric model of the TM was then constructed. Images of the TM at a baseline IOP level of 11, and elevated level of 23 mmHg were treated as the undeformed and deformed configurations, respectively. An inverse modeling technique was subsequently used to estimate the TM shear modulus ( G ). An optimization technique was used to find the shear modulus that minimized the difference between Schlemm's canal area in the in-vivo images and simulations. Upon completion of inverse finite element modeling, the simulated area of the Schlemm's canal changed from 8,889 µm 2 to 2,088 µm 2 , similar to the experimentally measured areal change of the canal (from 8,889 µm 2 to 2,100 µm 2 ). The calculated value of shear modulus was found to be 1.93 kPa, (implying an approximate Young's modulus of 5.75 kPa), which is consistent with previous ex-vivo measurements. The combined imaging and computational simulation technique provides a unique approach to calculate the mechanical properties of the TM in vivo without any surgical intervention. Quantification of such mechanical properties will help us examine the mechanistic role of TM biomechanics in

  17. SU-F-T-229: A Novel Method for EPID-Based In-Vivo Exit Dose Verification for Intensity Modulated Radiotherapy

    SciTech Connect

    Wu, Z; Wang, J; Peng, J

    Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), andmore » can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.« less

  18. Digital transillumination in caries detection versus radiographic and clinical methods: an in-vivo study

    PubMed Central

    Lara-Capi, Cynthia; Lingström, Peter; Lai, Gianfranco; Cocco, Fabio; Simark-Mattsson, Charlotte; Campus, Guglielmo

    2017-01-01

    Objectives: This article aimed to evaluate: (a) the agreement between a near-infrared light transillumination device and clinical and radiographic examinations in caries lesion detection and (b) the reliability of images captured by the transillumination device. Methods: Two calibrated examiners evaluated the caries status in premolars and molars on 52 randomly selected subjects by comparing the transillumination device with a clinical examination for the occlusal surfaces and by comparing the transillumination device with a radiographic examination (bitewing radiographs) for the approximal surfaces. Forty-eight trained dental hygienists evaluated and reevaluated 30 randomly selected images 1-month later. Results: A high concordance between transillumination method and clinical examination (kappa = 0.99) was detected for occlusal caries lesions, while for approximal surfaces, the transillumination device identified a higher number of lesions with respect to bitewing (kappa = 0.91). At the dentinal level, the two methods identified the same number of caries lesions (kappa = 1), whereas more approximal lesions were recorded using the transillumination device in the enamel (kappa = 0.24). The intraexaminer reliability was substantial/almost perfect in 59.4% of the participants. Conclusions: The transillumination method showed a high concordance compared with traditional methods (clinical examination and bitewing radiographs). Caries detection reliability using the transillumination device images showed a high intraexaminer agreement. Transillumination showed to be a reliable method and as effective as traditional methods in caries detection. PMID:28191797

  19. Continuous Shear Wave Elastography: a New Method to Measure in-vivo Viscoelastic Properties of Tendons

    PubMed Central

    Cortes, Daniel H.; Suydam, Stephen M.; Silbernagel, Karin Grävare; Buchanan, Thomas S.; Elliott, Dawn M.

    2015-01-01

    Viscoelastic mechanical properties are frequently altered after tendon injuries and during recovery. Therefore, non-invasive measurements of shear viscoelastic properties may help evaluate tendon recovery and compare the effectiveness of different therapies. The objectives of this study are to present an elastography method to measure localized viscoelastic properties of tendon and to present initial results in healthy and injured human Achilles and semitendinosus tendons. The technique used an external actuator to generate the shear waves in the tendon at different frequencies and plane wave imaging to measure shear wave displacements. For each of the excitation frequencies, maps of direction specific wave speeds were calculated using Local Frequency Estimation. Maps of viscoelastic properties were obtained using a pixel wise curve-fit of wave speed and frequency. The method was validated by comparing measurements of wave speed in agarose gels to those obtained using magnetic resonance elastography. Measurements in human healthy Achilles tendons revealed a pronounced increase in wave speed as function of frequency that highlights the importance of tendon viscoelasticity. Additionally, the viscoelastic properties of the Achilles tendon were larger than those reported for other tissues. Measurements in a tendinopathic Achilles tendon showed that it is feasible to quantify local viscoeasltic properties. Similarly, measurement in the semitendinosus tendon showed a substantial differences in viscoelastic properties between the healthy and contralateral tendons. Consequently, this technique has the potential of evaluating localized changes in tendon viscoelastic properties due to injury and during recovery in a clinical setting. PMID:25796414

  20. LANL seismic screening method for existing buildings

    SciTech Connect

    Dickson, S.L.; Feller, K.C.; Fritz de la Orta, G.O.

    1997-01-01

    The purpose of the Los Alamos National Laboratory (LANL) Seismic Screening Method is to provide a comprehensive, rational, and inexpensive method for evaluating the relative seismic integrity of a large building inventory using substantial life-safety as the minimum goal. The substantial life-safety goal is deemed to be satisfied if the extent of structural damage or nonstructural component damage does not pose a significant risk to human life. The screening is limited to Performance Category (PC) -0, -1, and -2 buildings and structures. Because of their higher performance objectives, PC-3 and PC-4 buildings automatically fail the LANL Seismic Screening Method andmore » will be subject to a more detailed seismic analysis. The Laboratory has also designated that PC-0, PC-1, and PC-2 unreinforced masonry bearing wall and masonry infill shear wall buildings fail the LANL Seismic Screening Method because of their historically poor seismic performance or complex behavior. These building types are also recommended for a more detailed seismic analysis. The results of the LANL Seismic Screening Method are expressed in terms of separate scores for potential configuration or physical hazards (Phase One) and calculated capacity/demand ratios (Phase Two). This two-phase method allows the user to quickly identify buildings that have adequate seismic characteristics and structural capacity and screen them out from further evaluation. The resulting scores also provide a ranking of those buildings found to be inadequate. Thus, buildings not passing the screening can be rationally prioritized for further evaluation. For the purpose of complying with Executive Order 12941, the buildings failing the LANL Seismic Screening Method are deemed to have seismic deficiencies, and cost estimates for mitigation must be prepared. Mitigation techniques and cost-estimate guidelines are not included in the LANL Seismic Screening Method.« less

  1. DHAD variants and methods of screening

    DOEpatents

    Kelly, Kristen J.; Ye, Rick W.

    2017-02-28

    Methods of screening for dihydroxy-acid dehydratase (DHAD) variants that display increased DHAD activity are disclosed, along with DHAD variants identified by these methods. Such enzymes can result in increased production of compounds from DHAD requiring biosynthetic pathways. Also disclosed are isolated nucleic acids encoding the DHAD variants, recombinant host cells comprising the isolated nucleic acid molecules, and methods of producing butanol.

  2. Evaluation of hydrate-screening methods.

    PubMed

    Cui, Yong; Yao, Erica

    2008-07-01

    The purpose of this work is to evaluate the effectiveness and reliability of several common hydrate-screening techniques, and to provide guidelines for designing hydrate-screening programs for new drug candidates. Ten hydrate-forming compounds were selected as model compounds and six hydrate-screening approaches were applied to these compounds in an effort to generate their hydrate forms. The results prove that no screening approach is universally effective in finding hydrates for small organic compounds. Rather, a combination of different methods should be used to improve screening reliability. Among the approaches tested, the dynamic water vapor sorption/desorption isotherm (DVI) method and storage under high humidity (HH) yielded 60-70% success ratios, the lowest among all techniques studied. The risk of false negatives arises in particular for nonhygroscopic compounds. On the other hand, both slurry in water (Slurry) and temperature cycling of aqueous suspension (TCS) showed high success rates (90%) with some exceptions. The mixed solvent systems (MSS) procedure also achieved high success rates (90%), and was found to be more suitable for water-insoluble compounds. For water-soluble compounds, MSS may not be the best approach because recrystallization is difficult in solutions with high water activity. Finally, vapor diffusion (VD) yielded a reasonably high success ratio in finding hydrates (80%). However, this method suffers from experimental difficulty and unreliable results for either highly water-soluble or water-insoluble compounds. This study indicates that a reliable hydrate-screening strategy should take into consideration the solubility and hygroscopicity of the compounds studied. A combination of the Slurry or TCS method with the MSS procedure could provide a screening strategy with reasonable reliability.

  3. A Screening Method for Assessing Cumulative Impacts

    PubMed Central

    Alexeeff, George V.; Faust, John B.; August, Laura Meehan; Milanes, Carmen; Randles, Karen; Zeise, Lauren; Denton, Joan

    2012-01-01

    The California Environmental Protection Agency (Cal/EPA) Environmental Justice Action Plan calls for guidelines for evaluating “cumulative impacts.” As a first step toward such guidelines, a screening methodology for assessing cumulative impacts in communities was developed. The method, presented here, is based on the working definition of cumulative impacts adopted by Cal/EPA [1]: “Cumulative impacts means exposures, public health or environmental effects from the combined emissions and discharges in a geographic area, including environmental pollution from all sources, whether single or multi-media, routinely, accidentally, or otherwise released. Impacts will take into account sensitive populations and socio-economic factors, where applicable and to the extent data are available.” The screening methodology is built on this definition as well as current scientific understanding of environmental pollution and its adverse impacts on health, including the influence of both intrinsic, biological factors and non-intrinsic socioeconomic factors in mediating the effects of pollutant exposures. It addresses disparities in the distribution of pollution and health outcomes. The methodology provides a science-based tool to screen places for relative cumulative impacts, incorporating both the pollution burden on a community- including exposures to pollutants, their public health and environmental effects- and community characteristics, specifically sensitivity and socioeconomic factors. The screening methodology provides relative rankings to distinguish more highly impacted communities from less impacted ones. It may also help identify which factors are the greatest contributors to a community’s cumulative impact. It is not designed to provide quantitative estimates of community-level health impacts. A pilot screening analysis is presented here to illustrate the application of this methodology. Once guidelines are adopted, the methodology can serve as a screening

  4. Apparatus and method for radioactive waste screening

    DOEpatents

    Akers, Douglas W.; Roybal, Lyle G.; Salomon, Hopi; Williams, Charles Leroy

    2012-09-04

    An apparatus and method relating to screening radioactive waste are disclosed for ensuring that at least one calculated parameter for the measurement data of a sample falls within a range between an upper limit and a lower limit prior to the sample being packaged for disposal. The apparatus includes a radiation detector configured for detecting radioactivity and radionuclide content of the of the sample of radioactive waste and generating measurement data in response thereto, and a collimator including at least one aperture to direct a field of view of the radiation detector. The method includes measuring a radioactive content of a sample, and calculating one or more parameters from the radioactive content of the sample.

  5. 42 CFR 455.452 - Other State screening methods.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Other State screening methods. 455.452 Section 455....452 Other State screening methods. Nothing in this subpart must restrict the State Medicaid agency from establishing provider screening methods in addition to or more stringent than those required by...

  6. 42 CFR 455.452 - Other State screening methods.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Other State screening methods. 455.452 Section 455....452 Other State screening methods. Nothing in this subpart must restrict the State Medicaid agency from establishing provider screening methods in addition to or more stringent than those required by...

  7. In-vitro and in-vivo study of amorphous spironolactone prepared by adsorption method using supercritical CO2.

    PubMed

    Jiang, Qikun; Li, Yuanyuan; Fu, Qiang; Geng, Yajie; Zhao, Juanhang; Ma, Panqin; Zhang, Tianhong

    2015-02-01

    The aim of this study was to improve the oral bioavailability of spironolactone (SP). SP was adsorbed on the fumed silica using supercritical CO2 (scCO2) technology and further compressed into tablets. The morphology was observed by scanning electron microscopy (SEM), and the crystalline form was investigated by differential scanning calorimetry (DSC) and powder X-ray diffraction (PXRD). The dissolution test was performed in water, 0.1 M HCl solution, pH 4.5 acetate buffers and pH 6.8 phosphate buffers using the paddle method. The pharmacokinetics was undertaken in six dogs in a crossover fashion. SP was successfully prepared into tablets and presented in amorphous state. SP-silica scCO2 tablets displayed higher dissolution profiles than SP-silica physical mixtures tablets in different media. The AUC0-t and Cmax of SP-silica supercritical CO2 was 1.61- and 1.52-fold greater than those of SP-silica physical mixtures (p < 0.05), respectively. It is a promising method in improving dissolution and bioavailability by adsorbing SP, a poorly soluble drug, on the fumed silica using rapid expansion of supercritical solutions.

  8. Tools and methods for experimental in-vivo measurement and biomechanical characterization of an Octopus vulgaris arm.

    PubMed

    Margheri, Laura; Mazzolai, Barbara; Cianchetti, Matteo; Dario, Paolo; Laschi, Cecilia

    2009-01-01

    This work illustrates new tools and methods for an in vivo and direct, but non-invasive, measurement of an octopus arm mechanical properties. The active elongation (longitudinal stretch) and the pulling force capability are measured on a specimen of Octopus vulgaris in order to quantitatively characterize the parameters describing the arm mechanics, for biomimetic design purposes. The novel approach consists of observing and measuring a living octopus with minimally invasive methods, which allow the animal to move with its complete ability. All tools are conceived in order to create a collaborative interaction with the animal for the acquisition of active measures. The data analysis is executed taking into account the presence of an intrinsic error due to the mobility of the subject and the aquatic environment. Using a system of two synchronized high-speed high-resolution cameras and purpose-made instruments, the maximum elongation of an arm and its rest length (when all muscles fibres are relaxed during propulsion movement) are measured and compared to define the longitudinal stretch, with the impressive average result of 194%. With a similar setup integrated with a force sensor, the pulling force capability is measured as a function of grasp point position along the arm. The measured parameters are used as real specifications for the design of an octopus-like arm with a biomimetic approach.

  9. Poster — Thur Eve — 25: Sensitivity to inhomogeneities for an in-vivo EPID dosimetry method

    SciTech Connect

    Peca, Stefano; Brown, Derek; Department of Physics and Astronomy, University of Calgary, Calgary, AB

    2014-08-15

    Introduction: The electronic portal imaging device (EPID) has the potential to be used for in vivo dosimetry during radiotherapy as an additional dose delivery check. We recently proposed a simple method of using the EPID for 2D-IVD based on correlation ratios. In this work we have investigated the sensitivity of our EPID-IVD to inhomogeneities. Methods: We used slab phantoms that simulate water, bone, and lung, arranged in various geometries. To simulate body contours non-orthogonal to the field, we used a water wedge. CT data of these phantoms was imported into MATLAB, in conjunction with EPID images acquired during irradiation, tomore » calculate dose inside the phantom in isocenter plane. Each phantom was irradiated using a linear accelerator while images were acquired with the EPID (cine mode). Comparisons between EPID-calculated and TPS dose maps were: pixel-by-pixel dose difference, and 3%,3mm gamma evaluation. Results: In the homogeneous case, CAX dose difference was <1%, and 3%,3mm gamma analysis yielded 99% of points with gamma<1. For the inhomogeneous phantoms, agreement decreased with increasing inhomogeneity reaching up to 10% CAX dose difference with 10cm of lung. Results from the water wedge phantom suggest that the EPID-calculated dose can account for surface irregularities of approximately ±3cm. Conclusions: The EPID-based IVD investigated has limitations in the presence of large inhomogeneities. Nonetheless, CAX doses never differed by >15% from the TPS. This suggests that this EPID-IVD is capable of detecting gross dose delivery errors even in the presence of inhomogeneities, supporting its utility as an additional patient safety device.« less

  10. Methylene blue dyeing of cellular nuclei during salpingoscopy, a new in-vivo method to evaluate vitality of tubal epithelium.

    PubMed

    Marconi, G; Quintana, R

    1998-12-01

    The Fallopian tube can be damaged by different noxious substances that may change cellular ultrastructure and function. Alteration of the cell membrane allows the passage of certain aniline dyes, which can stain the nucleus. A total of 310 Fallopian tubes from 163 patients who underwent a surgical or diagnostic laparoscopy during fertility studies was analysed by salpingoscopy. Cellular nuclei were stained by injection of 20 ml of a 10% solution of methylene blue in saline solution (NaCl 10%) through the cervical cannula prior to salpingoscopy. Evaluation of nuclear staining with methylene blue, adhesions, vascular alterations, and the flattening of folds in relation to pregnancy outcome was undertaken. Quantification of salpingoscopic findings was carried out according to a score. Flattening of folds and vascular alterations showed no difference in the pregnant and non-pregnant groups. On the other hand, adhesions and nuclear dyeing were significantly greater in the non-pregnant group (adhesions 13.6 versus 26.8%, P < 0.004, and nuclear dyeing: 25 versus 41.7%, P < 0.009, pregnant versus non-pregnant). Methylene blue dye is a new tool to evaluate in vivo cyto-histological tubal damage, and is a useful and simple method to provide a prognosis of salpingean function.

  11. Screening system and method of using same

    DOEpatents

    Jones, David A; Gresham, Christopher A; Basiliere, Marc L; Spates, James J; Rodacy, Philip J

    2014-04-15

    An integrated apparatus and method for screening an object for a target material is provided. The integrated apparatus comprises a housing and an integrated screener. The housing is positionable adjacent the object, and has a channel therethrough. The integrated screener is positionable in the housing, and comprises a fan, at least one filter, a heater and an analyzer. The fan is for drawing air carrying particles and vapor through the channel of the housing. The filter(s) is/are positionable in the channel of the housing for passage of the air therethrough. The filter(s) comprise(s) at least one metal foam having a plurality of pores therein for collecting and adsorbing a sample from the particles and vapor passing therethrough. The heater is for applying heat to the at least one metal foam whereby the collected sample is desorbed from the metal foam. The analyzer detects the target material from the desorbed sample.

  12. Laguerre-based method for analysis of time-resolved fluorescence data: application to in-vivo characterization and diagnosis of atherosclerotic lesions.

    PubMed

    Jo, Javier A; Fang, Qiyin; Papaioannou, Thanassis; Baker, J Dennis; Dorafshar, Amir H; Reil, Todd; Qiao, Jian-Hua; Fishbein, Michael C; Freischlag, Julie A; Marcu, Laura

    2006-01-01

    We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability.

  13. Laguerre-based method for analysis of time-resolved fluorescence data: application to in-vivo characterization and diagnosis of atherosclerotic lesions

    NASA Astrophysics Data System (ADS)

    Jo, Javier A.; Fang, Qiyin; Papaioannou, Thanassis; Baker, J. Dennis; Dorafshar, Amir; Reil, Todd; Qiao, Jianhua; Fishbein, Michael C.; Freischlag, Julie A.; Marcu, Laura

    2006-03-01

    We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability.

  14. Laguerre-based method for analysis of time-resolved fluorescence data: application to in-vivo characterization and diagnosis of atherosclerotic lesions

    PubMed Central

    Jo, Javier A.; Fang, Qiyin; Papaioannou, Thanassis; Baker, J. Dennis; Dorafshar, Amir H.; Reil, Todd; Qiao, Jian-Hua; Fishbein, Michael C.; Freischlag, Julie A.; Marcu, Laura

    2007-01-01

    We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability. PMID:16674179

  15. A systems wide mass spectrometric based linear motif screen to identify dominant in-vivo interacting proteins for the ubiquitin ligase MDM2.

    PubMed

    Nicholson, Judith; Scherl, Alex; Way, Luke; Blackburn, Elizabeth A; Walkinshaw, Malcolm D; Ball, Kathryn L; Hupp, Ted R

    2014-06-01

    Linear motifs mediate protein-protein interactions (PPI) that allow expansion of a target protein interactome at a systems level. This study uses a proteomics approach and linear motif sub-stratifications to expand on PPIs of MDM2. MDM2 is a multi-functional protein with over one hundred known binding partners not stratified by hierarchy or function. A new linear motif based on a MDM2 interaction consensus is used to select novel MDM2 interactors based on Nutlin-3 responsiveness in a cell-based proteomics screen. MDM2 binds a subset of peptide motifs corresponding to real proteins with a range of allosteric responses to MDM2 ligands. We validate cyclophilin B as a novel protein with a consensus MDM2 binding motif that is stabilised by Nutlin-3 in vivo, thus identifying one of the few known interactors of MDM2 that is stabilised by Nutlin-3. These data invoke two modes of peptide binding at the MDM2 N-terminus that rely on a consensus core motif to control the equilibrium between MDM2 binding proteins. This approach stratifies MDM2 interacting proteins based on the linear motif feature and provides a new biomarker assay to define clinically relevant Nutlin-3 responsive MDM2 interactors. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2001-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen is disclosed. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. The prescreen is preferably formed by a collection of light transmitting and refracting elements, preferably spheres 80, partially embedded in a light blocking layer. Toward the back of the spheres 80 are effective apertures 82 where the light blocking layer 81 is absent or at least thinner than in other regions toward the side of the spheres. The projected image enters spheres 80 through the effective apertures 82, and exits the spheres 80 centered orientationally about the normal to the lens axis. The re-oriented light rays then enter the diffusion screen for viewing.

  17. Wafer screening device and methods for wafer screening

    DOEpatents

    Sopori, Bhushan; Rupnowski, Przemyslaw

    2014-07-15

    Wafer breakage is a serious problem in the photovoltaic industry because a large fraction of wafers (between 5 and 10%) break during solar cell/module fabrication. The major cause of this excessive wafer breakage is that these wafers have residual microcracks--microcracks that were not completely etched. Additional propensity for breakage is caused by texture etching and incomplete edge grinding. To eliminate the cost of processing the wafers that break, it is best to remove them prior to cell fabrication. Some attempts have been made to develop optical techniques to detect microcracks. Unfortunately, it is very difficult to detect microcracks that are embedded within the roughness/texture of the wafers. Furthermore, even if such detection is successful, it is not straightforward to relate them to wafer breakage. We believe that the best way to isolate the wafers with fatal microcracks is to apply a stress to wafers--a stress that mimics the highest stress during cell/module processing. If a wafer survives this stress, it has a high probability of surviving without breakage during cell/module fabrication. Based on this, we have developed a high throughput, noncontact method for applying a predetermined stress to a wafer. The wafers are carried on a belt through a chamber that illuminates the wafer with an intense light of a predetermined intensity distribution that can be varied by changing the power to the light source. As the wafers move under the light source, each wafer undergoes a dynamic temperature profile that produces a preset elastic stress. If this stress exceeds the wafer strength, the wafer will break. The broken wafers are separated early, eliminating cost of processing into cell/module. We will describe details of the system and show comparison of breakage statistics with the breakage on a production line.

  18. Simultaneous determination of domperidone and Itopride in pharmaceuticals and human plasma using RP-HPLC/UV detection: Method development, validation and application of the method in in-vivo evaluation of fast dispersible tablets.

    PubMed

    Khan, Amjad; Iqbal, Zafar; Khadra, Ibrahim; Ahmad, Lateef; Khan, Abad; Khan, Muhammad Imran; Ullah, Zia; Ismail

    2016-03-20

    Domperidone and Itopride are pro-kinetic agents, regulating the gastric motility and are commonly prescribed as anti emetic drugs. In the present study a simple, rapid and sensitive RP-HPLC/UV method was developed for simultaneous determination of Domperidone and Itopride in pharmaceutical samples and human plasma, using Tenofavir as internal standard. Experimental conditions were optimized and method was validated according to the standard guidelines. Combination of water (pH 3.0) and acetonitrile (65:35 v/v) was used as mobile phase, pumped at the flow rate of 1.5 ml/min. Detector wavelength was set at 210 nm and column oven temperature was 40oC. Unlike conventional liquid-liquid extraction, simple precipitation technique was applied for drug extraction from human plasma using acetonitrile for deprotienation. The method showed adequate separation of both the analytes and best resolution was achieved using Hypersil BDS C8 column (150 mm × 4.6 mm, 5 μm). The method was quite linear in the range of 20-600 ng/ml. Recovery of the method was 92.31% and 89.82% for Domperidone and Itopride, respectively. Retention time of both the analytes and internal standard was below 15 min. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) for Domperidone were 5 and 10 ng/ml while for Itopride was 12 and 15 ng/ml, respectively. The developed method was successfully applied for in-vivo analysis of fast dispersible tablets of Domperidone in healthy human volunteer. The proposed method was a part of formulation development study and was efficiently applied for determination of the two drugs in various pharmaceutical products and human plasma. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Improvement of screening methods for silicon planar semiconductor devices

    NASA Technical Reports Server (NTRS)

    Berger, W. M.

    1972-01-01

    The results of the program for the development of a more sensitive method for selecting silicon planar semiconductor devices for long life applications are reported. The manufacturing technologies (MOS and Bipolar) are discussed along with the screening procedures developed as a result of the tests and evaluations, and the effectiveness of the MOS and Bilayer screening procedures are evaluated.

  20. A Triangulation Method for Identifying Hydrostratigraphic Locations of Well Screens

    SciTech Connect

    Whiteside, T. S.

    2015-01-31

    A method to identify the hydrostratigraphic location of well screens was developed using triangulation with known locations. This method was applied to all of the monitor wells being used to develop the new GSA groundwater model. Results from this method are closely aligned with those from an alternate method which uses a mesh surface.

  1. FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - INNOVATIVE TECHNOLOGY REPORT

    EPA Science Inventory

    This innovative technology evaluation report (ITER) presents information on the demonstration of the U.S. Environmental Protection Agency (EPA) Region 7 Superfund Field Analytical Screening Program (FASP) method for determining polychlorinated biphenyl (PCB) contamination in soil...

  2. The evolving role of new imaging methods in breast screening.

    PubMed

    Houssami, Nehmat; Ciatto, Stefano

    2011-09-01

    The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Effect of micro-environment modification and polymer type on the in-vitro dissolution behavior and in-vivo performance of amorphous solid dispersions.

    PubMed

    Sun, Weiwei; Pan, Baoliang

    2017-06-15

    This study investigates the effects of micro-environment modification and polymer type on the in-vitro dissolution behavior and in-vivo performance of micro-environment pH modifying solid dispersions (pH M -SD) for the poorly water-soluble model drug Toltrazuril (TOL). Various pH M -SDs were prepared using Ca(OH) 2 as a pH-modifier in hydrophilic polymers, including polyethylene glycol 6000 (PEG6000), polyvinylpyrrolidone k30 (PVPk30) and hydroxypropyl methylcellulose (HPMC). Based on the results of physicochemical characterizations and in-vitro dissolution testing, the representative ternary (Ca(OH) 2 :TOL:PEG6000/HPMC/PVPk30=1:8:24, w/w/w) and binary (TOL:PVPk30=1:3, w/w) solid dispersions were selected and optimized to perform in-vivo pharmacokinetic study. The micro-environment pH modification improved the in-vitro water-solubility and in-vivo bioavailability of parent drug TOL. Furthermore, the addition of alkalizers not only enhanced the release and absorption of prototype drug, but also promoted the generation of active metabolites, including toltrazuril sulfoxide (TOLSO) and toltrazuril sulfone (TOLSO 2 ). The in-vitro dissolution profiles and in-vivo absorption, distribution and metabolism behaviors of the pH M -SDs varied with polymer type. Moreover, in-vivo bioavailability of three active pharmaceutical ingredients increased with an increase in in-vitro dissolution rates of the drug from the pH M -SDs prepared with various polymers. Therefore, a non-sink in-vitro dissolution method can be used to predict the in-vivo performance of pH M -SDs formulated with various polymers with trend consistency. In-vitro and in-vivo screening procedures revealed that the pH M -SD composed of Ca(OH) 2 , TOL and PVPk30 at a weight ratio of 1:8:24, of which the safety was adequately proved via histopathological examination, may be a promising candidate for providing better clinical outcomes. Copyright © 2017. Published by Elsevier B.V.

  4. Method For Screening Microcrystallizations For Crystal Formation

    DOEpatents

    Santarsiero, Bernard D. , Stevens, Raymond C. , Schultz, Peter G. , Jaklevic, Joseph M. , Yegian, Derek T. , Cornell, Earl W. , Nordmeyer, Robert A.

    2003-10-07

    A method is provided for performing array microcrystallizations to determine suitable crystallization conditions for a molecule, the method comprising: forming an array of microcrystallizations, each microcrystallization comprising a drop comprising a mother liquor solution whose composition varies within the array and a molecule to be crystallized, the drop having a volume of less than 1 microliter; storing the array of microcrystallizations under conditions suitable for molecule crystals to form in the drops in the array; and detecting molecule crystal formation in the drops by taking images of the drops.

  5. EVALUATION OF POHC AND PIC SCREENING METHODS

    EPA Science Inventory

    A recurring theme in environmental work is the need to characterize emissions to the maximum extent at the minimum cost. Unfortunately, many projects have been carried out In the past with little thought or planning concerning the optimum application of analytical methods availab...

  6. NEW METHODS TO SCREEN FOR DEVELOPMENTAL NEUROTOXICITY.

    EPA Science Inventory

    The development of alternative methods for toxicity testing is driven by the need for scientifically valid data (i.e. predictive of a toxic effect) that can be obtained in a rapid and cost-efficient manner. These predictions will enable decisions to be made as to whether further ...

  7. Intersection of Screening Methods High Quantile

    EPA Pesticide Factsheets

    This layer combines the high quantiles of the CES, CEVA, and EJSM layers so that viewers can see the overlap of 00e2??hot spots00e2?? for each method. This layer was created by James Sadd of Occidental College of Los Angeles

  8. Rational Methods for the Selection of Diverse Screening Compounds

    PubMed Central

    Huggins, David J.; Venkitaraman, Ashok R.; Spring, David R.

    2016-01-01

    Traditionally a pursuit of large pharmaceutical companies, high-throughput screening assays are becoming increasingly common within academic and government laboratories. This shift has been instrumental in enabling projects that have not been commercially viable, such as chemical probe discovery and screening against high risk targets. Once an assay has been prepared and validated, it must be fed with screening compounds. Crafting a successful collection of small molecules for screening poses a significant challenge. An optimized collection will minimize false positives whilst maximizing hit rates of compounds that are amenable to lead generation and optimization. Without due consideration of the relevant protein targets and the downstream screening assays, compound filtering and selection can fail to explore the great extent of chemical diversity and eschew valuable novelty. Herein, we discuss the different factors to be considered and methods that may be employed when assembling a structurally diverse compound screening collection. Rational methods for selecting diverse chemical libraries are essential for their effective use in high-throughput screens. PMID:21261294

  9. Diagnostic methods for platelet bacteria screening: current status and developments.

    PubMed

    Störmer, Melanie; Vollmer, Tanja

    2014-02-01

    Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes.

  10. Diagnostic Methods for Platelet Bacteria Screening: Current Status and Developments

    PubMed Central

    Störmer, Melanie; Vollmer, Tanja

    2014-01-01

    Summary Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes. PMID:24659944

  11. FIELD ANALYTICAL SCREENING PROGRAM: PCP METHOD - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The Field Analytical Screening Program (FASP) pentachlorophenol (PCP) method uses a gas chromatograph (GC) equipped with a megabore capillary column and flame ionization detector (FID) and electron capture detector (ECD) to identify and quantify PCP. The FASP PCP method is design...

  12. Screening-Level Ecological Risk Assessment Methods, Revision 3

    SciTech Connect

    Mirenda, Richard J.

    2012-08-16

    This document provides guidance for screening-level assessments of potential adverse impacts to ecological resources from release of environmental contaminants at the Los Alamos National Laboratory (LANL or the Laboratory). The methods presented are based on two objectives, namely: to provide a basis for reaching consensus with regulators, managers, and other interested parties on how to conduct screening-level ecological risk investigations at the Laboratory; and to provide guidance for ecological risk assessors under the Environmental Programs (EP) Directorate. This guidance promotes consistency, rigor, and defensibility in ecological screening investigations and in reporting those investigation results. The purpose of the screening assessmentmore » is to provide information to the risk managers so informed riskmanagement decisions can be made. This document provides examples of recommendations and possible risk-management strategies.« less

  13. Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system.

    PubMed

    Hanson, Ian M; Hansen, Vibeke N; Olaciregui-Ruiz, Igor; van Herk, Marcel

    2014-10-07

    Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients.The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min.The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7  ±  3.2)%.EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.

  14. Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system

    NASA Astrophysics Data System (ADS)

    Hanson, Ian M.; Hansen, Vibeke N.; Olaciregui-Ruiz, Igor; van Herk, Marcel

    2014-10-01

    Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients. The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min. The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7  ±  3.2)%. EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.

  15. Using the Screened Coulomb Potential to Illustrate the Variational Method

    ERIC Educational Resources Information Center

    Zuniga, Jose; Bastida, Adolfo; Requena, Alberto

    2012-01-01

    The screened Coulomb potential, or Yukawa potential, is used to illustrate the application of the single and linear variational methods. The trial variational functions are expressed in terms of Slater-type functions, for which the integrals needed to carry out the variational calculations are easily evaluated in closed form. The variational…

  16. Screening Methods for Metal-Containing Nanoparticles in Water

    EPA Science Inventory

    Screening-level analysis of water for metal-containing nanoparticles is achieved with single particle-inductively coupled plasma mass spectrometry (SP-ICPMS). This method measures both the concentration of nanoparticles containing an analyte metal and the mass of the metal in eac...

  17. FIELD SCREENING METHODS FOR HAZARDOUS WASTES AND TOXIC CHEMICALS

    EPA Science Inventory

    The purpose of this document is to present the technical papers that were presented at the Second International Symposium on Field Screening Methods for Hazardous Wastes and Toxic Chemicals. ixty platform presentations were made and included in one of ten sessions: hemical sensor...

  18. A screening method for biotinidase deficiency in newborns.

    PubMed

    Heard, G S; Secor McVoy, J R; Wolf, B

    1984-01-01

    We describe a method for neonatal screening for biotinidase (EC 3.5.1.12) deficiency. Biotinidase activity is assessed colorimetrically from dried samples of whole blood spotted on the same filter papers as used in the neonatal screening for phenylketonuria. After the reaction, samples from normal infants are characteristically purple, whereas those from affected individuals are straw-colored. To confirm the deficiency, the enzyme is quantitatively assayed in additional blood spots or serum. A pilot study has been initiated with samples obtained by the Commonwealth of Virginia for phenylketonuria testing.

  19. A deep learning method for early screening of lung cancer

    NASA Astrophysics Data System (ADS)

    Zhang, Kunpeng; Jiang, Huiqin; Ma, Ling; Gao, Jianbo; Yang, Xiaopeng

    2018-04-01

    Lung cancer is the leading cause of cancer-related deaths among men. In this paper, we propose a pulmonary nodule detection method for early screening of lung cancer based on the improved AlexNet model. In order to maintain the same image quality as the existing B/S architecture PACS system, we convert the original CT image into JPEG format image by analyzing the DICOM file firstly. Secondly, in view of the large size and complex background of CT chest images, we design the convolution neural network on basis of AlexNet model and sparse convolution structure. At last we train our models on the software named DIGITS which is provided by NVIDIA. The main contribution of this paper is to apply the convolutional neural network for the early screening of lung cancer and improve the screening accuracy by combining the AlexNet model with the sparse convolution structure. We make a series of experiments on the chest CT images using the proposed method, of which the sensitivity and specificity indicates that the method presented in this paper can effectively improve the accuracy of early screening of lung cancer and it has certain clinical significance at the same time.

  20. A spectrophotometric screening method for avermectin oxidizing microorganisms.

    PubMed

    Wang, Yuan-Shan; Hu, Qi-Wei; Zheng, Xing-Chang; Zhang, Jian-Fen; Zheng, Yu-Guo

    2017-04-01

    A spectrophotometric screening method for avermectin oxidizing microbes by determination of 4″-oxo-avermectin was established based on the reaction between 4″-oxo-avermectin and 2,4-dinitrophenylhydrazine. Combined with a gradient HPLC assay, microorganisms capable of regioselectively oxidizing avermectin to 4″-oxo-avermectin were successfully obtained by this method. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Diagnostic methods of TSH in thyroid screening tests.

    PubMed

    Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J

    2013-01-01

    Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.

  2. [Screening methods for mild cognitive impairment in primary care].

    PubMed

    Freire Pérez, Alberto

    2017-06-01

    Diagnosis of mild cognitive impairment (MCI) is always clinical and screening methods only indicate that the patient has a higher risk of this condition. In MCI, there is a slight decline in some cognitive abilities that does not affect activities of daily living and therefore does not produce social or occupational disability. The definitive diagnosis of MCI requires a considerable time investment that is very rarely possible to provide in primary care (PC) consultations. Hence the need for PC physicians to employ rapid and simple screening methods (brief cognitive assessment -BCA-) that allow objective identification of patients likely to have MCI in a few minutes. This article reviews the BCA tools that can truly be applied in less than 10 minutes. The phototest is a brief screening tool that is easy to use and interpret by physicians and is well accepted by patients. Consequently, it is one of the most useful tests in PC for screening of both MCI and dementia. In addition to BCA, instrumental activities of daily living scales should also be applied to differentiate MCI from dementia. Copyright © 2017 Sociedad Española de Geriatría y Gerontología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. A novel accelerated oxidative stability screening method for pharmaceutical solids.

    PubMed

    Zhu, Donghua Alan; Zhang, Geoff G Z; George, Karen L S T; Zhou, Deliang

    2011-08-01

    Despite the fact that oxidation is the second most frequent degradation pathway for pharmaceuticals, means of evaluating the oxidative stability of pharmaceutical solids, especially effective stress testing, are still lacking. This paper describes a novel experimental method for peroxide-mediated oxidative stress testing on pharmaceutical solids. The method utilizes urea-hydrogen peroxide, a molecular complex that undergoes solid-state decomposition and releases hydrogen peroxide vapor at elevated temperatures (e.g., 30°C), as a source of peroxide. The experimental setting for this method is simple, convenient, and can be operated routinely in most laboratories. The fundamental parameter of the system, that is, hydrogen peroxide vapor pressure, was determined using a modified spectrophotometric method. The feasibility and utility of the proposed method in solid form selection have been demonstrated using various solid forms of ephedrine. No degradation was detected for ephedrine hydrochloride after exposure to the hydrogen peroxide vapor for 2 weeks, whereas both anhydrate and hemihydrate free base forms degraded rapidly under the test conditions. In addition, both the anhydrate and the hemihydrate free base degraded faster when exposed to hydrogen peroxide vapor at 30°C under dry condition than at 30°C/75% relative humidity (RH). A new degradation product was also observed under the drier condition. The proposed method provides more relevant screening conditions for solid dosage forms, and is useful in selecting optimal solid form(s), determining potential degradation products, and formulation screening during development. Copyright © 2011 Wiley-Liss, Inc.

  4. Circling motion and screen edges as an alternative input method for on-screen target manipulation.

    PubMed

    Ka, Hyun W; Simpson, Richard C

    2017-04-01

    To investigate a new alternative interaction method, called circling interface, for manipulating on-screen objects. To specify a target, the user makes a circling motion around the target. To specify a desired pointing command with the circling interface, each edge of the screen is used. The user selects a command before circling the target. To evaluate the circling interface, we conducted an experiment with 16 participants, comparing the performance on pointing tasks with different combinations of selection method (circling interface, physical mouse and dwelling interface) and input device (normal computer mouse, head pointer and joystick mouse emulator). A circling interface is compatible with many types of pointing devices, not requiring physical activation of mouse buttons, and is more efficient than dwell-clicking. Across all common pointing operations, the circling interface had a tendency to produce faster performance with a head-mounted mouse emulator than with a joystick mouse. The performance accuracy of the circling interface outperformed the dwelling interface. It was demonstrated that the circling interface has the potential as another alternative pointing method for selecting and manipulating objects in a graphical user interface. Implications for Rehabilitation A circling interface will improve clinical practice by providing an alternative pointing method that does not require physically activating mouse buttons and is more efficient than dwell-clicking. The Circling interface can also work with AAC devices.

  5. A Quantum-Based Similarity Method in Virtual Screening.

    PubMed

    Al-Dabbagh, Mohammed Mumtaz; Salim, Naomie; Himmat, Mubarak; Ahmed, Ali; Saeed, Faisal

    2015-10-02

    One of the most widely-used techniques for ligand-based virtual screening is similarity searching. This study adopted the concepts of quantum mechanics to present as state-of-the-art similarity method of molecules inspired from quantum theory. The representation of molecular compounds in mathematical quantum space plays a vital role in the development of quantum-based similarity approach. One of the key concepts of quantum theory is the use of complex numbers. Hence, this study proposed three various techniques to embed and to re-represent the molecular compounds to correspond with complex numbers format. The quantum-based similarity method that developed in this study depending on complex pure Hilbert space of molecules called Standard Quantum-Based (SQB). The recall of retrieved active molecules were at top 1% and top 5%, and significant test is used to evaluate our proposed methods. The MDL drug data report (MDDR), maximum unbiased validation (MUV) and Directory of Useful Decoys (DUD) data sets were used for experiments and were represented by 2D fingerprints. Simulated virtual screening experiment show that the effectiveness of SQB method was significantly increased due to the role of representational power of molecular compounds in complex numbers forms compared to Tanimoto benchmark similarity measure.

  6. New screening methods for donor eye-bank eyes.

    PubMed

    Terry, M A; Ousley, P J

    1999-07-01

    Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening. Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results. The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD. Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.

  7. Methods for external event screening quantification: Risk Methods Integration and Evaluation Program (RMIEP) methods development

    SciTech Connect

    Ravindra, M.K.; Banon, H.

    1992-07-01

    In this report, the scoping quantification procedures for external events in probabilistic risk assessments of nuclear power plants are described. External event analysis in a PRA has three important goals; (1) the analysis should be complete in that all events are considered; (2) by following some selected screening criteria, the more significant events are identified for detailed analysis; (3) the selected events are analyzed in depth by taking into account the unique features of the events: hazard, fragility of structures and equipment, external-event initiated accident sequences, etc. Based on the above goals, external event analysis may be considered as amore » three-stage process: Stage I: Identification and Initial Screening of External Events; Stage II: Bounding Analysis; Stage III: Detailed Risk Analysis. In the present report, first, a review of published PRAs is given to focus on the significance and treatment of external events in full-scope PRAs. Except for seismic, flooding, fire, and extreme wind events, the contributions of other external events to plant risk have been found to be negligible. Second, scoping methods for external events not covered in detail in the NRC's PRA Procedures Guide are provided. For this purpose, bounding analyses for transportation accidents, extreme winds and tornadoes, aircraft impacts, turbine missiles, and chemical release are described.« less

  8. Methods for external event screening quantification: Risk Methods Integration and Evaluation Program (RMIEP) methods development

    SciTech Connect

    Ravindra, M.K.; Banon, H.

    1992-07-01

    In this report, the scoping quantification procedures for external events in probabilistic risk assessments of nuclear power plants are described. External event analysis in a PRA has three important goals; (1) the analysis should be complete in that all events are considered; (2) by following some selected screening criteria, the more significant events are identified for detailed analysis; (3) the selected events are analyzed in depth by taking into account the unique features of the events: hazard, fragility of structures and equipment, external-event initiated accident sequences, etc. Based on the above goals, external event analysis may be considered as amore » three-stage process: Stage I: Identification and Initial Screening of External Events; Stage II: Bounding Analysis; Stage III: Detailed Risk Analysis. In the present report, first, a review of published PRAs is given to focus on the significance and treatment of external events in full-scope PRAs. Except for seismic, flooding, fire, and extreme wind events, the contributions of other external events to plant risk have been found to be negligible. Second, scoping methods for external events not covered in detail in the NRC`s PRA Procedures Guide are provided. For this purpose, bounding analyses for transportation accidents, extreme winds and tornadoes, aircraft impacts, turbine missiles, and chemical release are described.« less

  9. METHOD FOR SIMULTANEOUS 90SR AND 137CS IN-VIVO MEASUREMENTS OF SMALL ANIMALS AND OTHER ENVIRONMENTAL MEDIA DEVELOPED FOR THE CONDITIONS OF THE CHERNOBYL EXCLUSION ZONE

    SciTech Connect

    Farfan, E.; Jannik, T.

    To perform in vivo simultaneous measurements of the {sup 90}Sr and {sup 137}Cs content in the bodies of animals living in the Chernobyl Exclusion Zone (ChEZ), an appropriate method and equipment were developed and installed in a mobile gamma beta spectrometry laboratory. This technique was designed for animals of relatively small sizes (up to 50 g). The {sup 90}Sr content is measured by a beta spectrometer with a 0.1 mm thick scintillation plastic detector. The spectrum processing takes into account the fact that the measured object is 'thick-layered' and contains a comparable quantity of {sup 137}Cs, which is a characteristicmore » condition of the ChEZ. The {sup 137}Cs content is measured by a NaI scintillation detector that is part of the combined gamma beta spectrometry system. For environmental research performed in the ChEZ, the advantages of this method and equipment (rapid measurements, capability to measure live animals directly in their habitat, and the capability of simultaneous {sup 90}Sr and {sup 137}Cs measurements) far outweigh the existing limitations (considerations must be made for background radiation and the animal size, skeletal shape and body mass). The accuracy of these in vivo measurements is shown to be consistent with standard spectrometric and radiochemical methods. Apart from the in vivo measurements, the proposed methodology, after a very simple upgrade that is also described in the article, works even more accurately with samples of other media, such as soil and plants.« less

  10. In-vivo singlet oxygen threshold doses for PDT

    PubMed Central

    Zhu, Timothy C.; Kim, Michele M.; Liang, Xing; Finlay, Jarod C.; Busch, Theresa M.

    2015-01-01

    Objective Dosimetry of singlet oxygen (1O2) is of particular interest because it is the major cytotoxic agent causing biological effects for type-II photosensitizers during photodynamic therapy (PDT). An in-vivo model to determine the singlet oxygen threshold dose, [1O2]rx,sh, for PDT was developed. Material and methods An in-vivo radiation-induced fibrosarcoma (RIF) tumor mouse model was used to correlate the radius of necrosis to the calculation based on explicit PDT dosimetry of light fluence distribution, tissue optical properties, and photosensitizer concentrations. Inputs to the model include five photosensitizer-specific photochemical parameters along with [1O2]rx,sh. Photosensitizer-specific model parameters were determined for benzoporphyrin derivative monoacid ring A (BPD) and compared with two other type-II photosensitizers, Photofrin® and m-tetrahydroxyphenylchlorin (mTHPC) from the literature. Results The mean values (standard deviation) of the in-vivo [1O2]rx,sh are approximately 0.56 (0.26) and 0.72 (0.21) mM (or 3.6×107 and 4.6×107 singlet oxygen per cell to reduce the cell survival to 1/e) for Photofrin® and BPD, respectively, assuming that the fraction of generated singlet oxygen that interacts with the cell is 1. While the values for the photochemical parameters (ξ, σ, g, β) used for BPD were preliminary and may need further refinement, there is reasonable confidence for the values of the singlet oxygen threshold doses. Discussion In comparison, the [1O2]rx,sh value derived from in-vivo mouse study was reported to be 0.4 mM for mTHPC-PDT. However, the singlet oxygen required per cell is reported to be 9×108 per cell per 1/e fractional kill in an in-vitro mTHPC-PDT study on a rat prostate cancer cell line (MLL cells) and is reported to be 7.9 mM for a multicell in-vitro EMT6/Ro spheroid model for mTHPC-PDT. A theoretical analysis is provided to relate the number of in-vitro singlet oxygen required per cell to reach cell killing of 1/e to

  11. Method for in vitro screening of aquatic fungicides

    USGS Publications Warehouse

    Bailey, T.A.

    1983-01-01

    Methods were developed for in vitro screening of candidate aquatic fungicides for efficacy against Achlya fiagellata, A. racemosa, Saprolegnia hypogyna and S. megasperma. Agar plugs containing fungal hyphae, removed from the edge of actively growing colonies, were placed in the depressions of spot plates containing 1a??0, 10a??0 and 100 mg/I of the candidate compounds for 15 or 60 min. After exposure, the plugs were transferred on to filter papers (0a??45-A?m pore) in a holder, rinsed, and then placed on cornmeal agar medium in tri-petri dishes. The plates were checked for mycelial growth after 48, 96 and 168 h of incubation in a lighted (400-800 A?m) environmental control chamber at 20A?2A?C. Criteria for the acceptance or rejection of candidate aquatic fungicides for further study were based on the antifungal spectrum index (ASI) comparisons between respective compounds and malachite green after 48 h and the concentration level producing complete growth inhibition. Candidate compounds whose ASI was less than 50% that of malachite green after 48 h or did not inhibit growth at levels less than 100 mg/l were rejected. This method provides a base from which in vivo and definitive test regimens can be developed. Preliminary in vitro screening of candidate fungicides reduces the need for costly in vivo tests on compounds that have low antifungal activity.

  12. SU-F-T-682: In-Vivo Simulation of the Relative Biological Effectiveness in Proton Therapy Using a Monte Carlo Method

    SciTech Connect

    Oesten, H; Massachusetts General Hospital, Boston, MA; Loeck, S

    2016-06-15

    Purpose: In proton therapy, the relative biological effectiveness (RBE) – compared with conventional photon therapy – is routinely set to 1.1. However, experimental in vitro studies indicate evidence for the variability of the RBE. To clarify the impact on patient treatment, investigation of the RBE in a preclinical case study should be performed. Methods: The Monte Carlo software TOPAS was used to simulate the radiation field of an irradiation setup at the experimental beamline of the proton therapy facility (OncoRay) in Dresden, Germany. Simulations were performed on cone beam CT-data (CBCT) of a xenogeneous mouse with an orthotopic lung carcinomamore » obtained by an in-house developed small animal image-guided radiotherapy device. A homogeneous physical fraction dose of 1.8Gy was prescribed for the contoured tumor volume. Simulated dose and linear energy transfer distributions were used to estimate RBE values in the mouse based on an RBE model by Wedenberg et al. To characterize radiation sensitivity of normal and tumor tissue, α/β-ratios were taken from the literature for NB1RGB (10.1Gy) and human squamous lung cancer (6.2Gy) cell lines, respectively. Results: Good dose coverage of the target volume was achieved with a spread-out Bragg peak (SOBP). The contra-lateral lung was completely spared from receiving radiation. An increase in RBE towards the distal end of the SOBP from 1.07 to 1.35 and from 1.05 to 1.3 was observed when considering normal tissue and tumor, respectively, with the highest RBE values located distal to the target volume. Conclusion: Modeled RBE values simulated on CBCT for experimental preclinical proton therapy varied with tissue type and depth in a mouse and differed therefore from a constant value of 1.1. Further translational work will include, first, conducting preclinical experiments and, second, analogous RBE studies in patients using experimentally verified simulation settings for our clinically used patient-specific beam

  13. Cognitive Change Questionnaire as a method for cognitive impairment screening

    PubMed Central

    Damin, Antonio Eduardo; Nitrini, Ricardo; Brucki, Sonia Maria Dozzi

    2015-01-01

    The Cognitive Change Questionnaire (CCQ) was created as an effective measure of cognitive change that is easy to use and suitable for application in Brazil. Objective To evaluate whether the CCQ can accurately distinguish normal subjects from individuals with Mild Cognitive Impairment (MCI) and/or early stage dementia and to develop a briefer questionnaire, based on the original 22-item CCQ (CCQ22), that contains fewer questions. Methods A total of 123 individuals were evaluated: 42 healthy controls, 40 patients with MCI and 41 with mild dementia. The evaluation was performed using cognitive tests based on individual performance and on questionnaires administered to informants. The CCQ22 was created based on a selection of questions that experts deemed useful in screening for early stage dementia. Results The CCQ22 showed good accuracy for distinguishing between the groups. Statistical models selected the eight questions with the greatest power to discriminate between the groups. The AUC ROC corresponding to the final version of the 8-item CCQ (CCQ8), demonstrated good accuracy in differentiating between groups, good correlation with the final diagnosis (r=0.861) and adequate internal consistency (Cronbach's α=0.876). Conclusion The CCQ8 can be used to accurately differentiate between normal subjects and individuals with cognitive impairment, constituting a brief and appropriate instrument for cognitive screening. PMID:29213967

  14. Screening portal, system and method of using same

    DOEpatents

    Linker, Kevin L.; Hunter, John A.; Brusseau, Charles A.

    2013-04-30

    A portal, system and method for screening an object for a target substance is provided. The portal includes an inflatable bladder expandable to form a test space for receiving the object and a plurality of nozzles positioned about the inflatable bladder. The nozzles are in fluid communication with a fluid source for directing air over the object whereby samples are removed from the object for examination. A collector is operatively connected to the inflatable bladder for collecting the samples removed from the object. A detector is operatively connected to the collector for examining the removed samples for the presence of the target substance. At least one preconcentrator may be operatively connected to the collector for concentrating the samples collected thereby.

  15. Display methods of electronic patient record screens: patient privacy concerns.

    PubMed

    Niimi, Yukari; Ota, Katsumasa

    2013-01-01

    To provide adequate care, medical professionals have to collect not only medical information but also information that may be related to private aspects of the patient's life. With patients' increasing awareness of information privacy, healthcare providers have to pay attention to the patients' right of privacy. This study aimed to clarify the requirements of the display method of electronic patient record (EPR) screens in consideration of both patients' information privacy concerns and health professionals' information needs. For this purpose, semi-structured group interviews were conducted of 78 medical professionals. They pointed out that partial concealment of information to meet patients' requests for privacy could result in challenges in (1) safety in healthcare, (2) information sharing, (3) collaboration, (4) hospital management, and (5) communication. They believed that EPRs should (1) meet the requirements of the therapeutic process, (2) have restricted access, (3) provide convenient access to necessary information, and (4) facilitate interprofessional collaboration. This study provides direction for the development of display methods that balance the sharing of vital information and protection of patient privacy.

  16. [Use of Plusoptix as a screening method for refractive ambliopia].

    PubMed

    Bogdănici, T; Tone, Silvia; Miron, Mihaela; Boboc, Mihaela; Bogdănici, Camelia

    2012-01-01

    Highlighting the differences in the objective refraction using the Plusoptix AO9 comparing them with the refraction performed with TOPCON KR-8900 autorefractor. Prospective study for 3 months held in the Ophthalmology Clinic in Iasi, Hospital Sf. Spiridon on a total of 39 children (21 girls and 18 boys) with mean age of 10.61 +/- 5.67 years. Clinical parameters: sex, age, objective refraction obtained with Plusoptix and with autorefractor corrected visual acuity (with different methods depending on each patient age), ortoptic examination (strabic deviation, binocular vision), the presence of symetry/asymetry while measuring with Plusoptix. The results were statistically processed by F-TEST calculating the correlation coefficient, standard deviation, significance level (using the spherical equivalent of the obtained values). Age limits of the studied cases ranged between 2-23 years. Visual acuity of children who had cooperate was between 0.2-1 with correction, achieving best values on right eye than left eye. 8 cases (20.51%) had large differences between measurements made with Plusoptix and autorefractor, half of that (4 cases) had strabismus. Three of these cases were with small hypermetropia and one with small myopia (Plusoptix shows a lower value). In 2 cases occurred higher differences (about 2-2,5D) between the 2 measurements, in patients with average hypermetropia. Plusoptix refraction was not possible at high hypermetropia or high myopia. This type of determining objective refraction using Plusoptix is a useful method of screening for discovery of refractive errors that can cause refractive amblyopia in young children and in those cases with a difficult collaboration. Because there are differences betweeti this 2 methods, for children with refractive errors are recommended further exploration to determine the appropriate optical correction. Plusoptix is a limited method because it cannot detect the exact values in those cases with high hypermetropia or high

  17. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Use of unbalanced laminates as a screening method for microcracking

    NASA Technical Reports Server (NTRS)

    Papadopoulos, Demetrios S.; Bowles, Kenneth J.

    1990-01-01

    State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.

  19. A screening method for cardiovascular active compounds in marine algae.

    PubMed

    Agatonovic-Kustrin, S; Kustrin, E; Angove, M J; Morton, D W

    2018-05-18

    The interaction of bioactive compounds from ethanolic extracts of selected marine algae samples, separated on chromatographic plates, with nitric/nitrous acid was investigated. The nature of bioactive compounds in the marine algae extracts was characterised using UV absorption spectra before and after reaction with diluted nitric acid, and from the characteristic colour reaction after derivatization with anisaldehyde. It was found that diterpenes from Dictyota dichotoma, an edible brown algae, and sterols from green algae Caulerpa brachypus, bind nitric oxide and may act as a nitric oxide carrier. Although the carotenoid fucoxanthin, found in all brown marine algae also binds nitric oxide, the bonds between nitrogen and the fucoxanthin molecule are much stronger. Further studies are required to evaluate the effects of diterpenes from Dictyota dichotoma and sterols from green algae Caulerpa brachypus to see if they have beneficial cardiovascular effects. The method reported here should prove useful in screening large numbers of algae species for compounds with cardiovascular activity. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Randomized Comparison of 3 Methods to Screen for Domestic Violence in Family Practice

    PubMed Central

    Chen, Ping-Hsin; Rovi, Sue; Washington, Judy; Jacobs, Abbie; Vega, Marielos; Pan, Ko-Yu; Johnson, Mark S.

    2007-01-01

    PURPOSE We undertook a study to compare 3 ways of administering brief domestic violence screening questionnaires: self-administered questionnaire, medical staff interview, and physician interview. METHODS We conducted a randomized trial of 3 screening protocols for domestic violence in 4 urban family medicine practices with mostly minority patients. We randomly assigned 523 female patients, aged 18 years or older and currently involved with a partner, to 1 of 3 screening protocols. Each included 2 brief screening tools: HITS and WAST-Short. Outcome measures were domestic violence disclosure, patient and clinician comfort with the screening, and time spent screening. RESULTS Overall prevalence of domestic violence was 14%. Most patients (93.4%) and clinicians (84.5%) were comfortable with the screening questions and method of administering them. Average time spent screening was 4.4 minutes. Disclosure rates, patient and clinician comfort with screening, and time spent screening were similar among the 3 protocols. In addition, WAST-Short was validated in this sample of minority women by comparison with HITS and with the 8-item WAST. CONCLUSIONS Domestic violence is common, and we found that most patients and clinicians are comfortable with domestic violence screening in urban family medicine settings. Patient self-administered domestic violence screening is as effective as clinician interview in terms of disclosure, comfort, and time spent screening. PMID:17893385

  1. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry

    SciTech Connect

    Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Cagnon, Chris H.

    Purpose: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. Methods: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for allmore » exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. Results: The calculated mean percent difference between TLD measurements and Monte Carlo simulations was −4.9% with standard deviation of 8.7% and a range of −22.7% to 5.7%. Conclusions: The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.« less

  2. Virtual screening methods as tools for drug lead discovery from large chemical libraries.

    PubMed

    Ma, X H; Zhu, F; Liu, X; Shi, Z; Zhang, J X; Yang, S Y; Wei, Y Q; Chen, Y Z

    2012-01-01

    Virtual screening methods have been developed and explored as useful tools for searching drug lead compounds from chemical libraries, including large libraries that have become publically available. In this review, we discussed the new developments in exploring virtual screening methods for enhanced performance in searching large chemical libraries, their applications in screening libraries of ~ 1 million or more compounds in the last five years, the difficulties in their applications, and the strategies for further improving these methods.

  3. An Efficient Variable Screening Method for Effective Surrogate Models for Reliability-Based Design Optimization

    DTIC Science & Technology

    2014-04-01

    surrogate model generation is difficult for high -dimensional problems, due to the curse of dimensionality. Variable screening methods have been...a variable screening model was developed for the quasi-molecular treatment of ion-atom collision [16]. In engineering, a confidence interval of...for high -level radioactive waste [18]. Moreover, the design sensitivity method can be extended to the variable screening method because vital

  4. [Possibilities of the TruScreen for screening of precancer and cancer of the uterine cervix].

    PubMed

    Zlatkov, V

    2009-01-01

    The classic approach of detection of pre-cancer and cancer of uterine cervix includes cytological examination, followed by colposcopy assessment of the detected cytological abnormalities. Real-time devices use in-vivo techniques for the measurement, computerized analysis and classifying of different types of cervical tissues. The aim of the present review is to present the technical characteristics and to discus the diagnostic possibilities of TruScreen-automated optical-electron system for cervical screening. The analysis of the presented in the literature diagnostic value of the method at different grades intraepithelial lesions shows that it has higher sensitivity (67-70%) and lower specificity (81%) in comparison to the Pap test with the following results (45-69% sensitivity and 95% specificity). This makes the method suitable for independent primary screening, as well as for adding the diagnostic assurance of the cytological method.

  5. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  6. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.

    PubMed

    Bostani, Maryam; Mueller, Jonathon W; McMillan, Kyle; Cody, Dianna D; Cagnon, Chris H; DeMarco, John J; McNitt-Gray, Michael F

    2015-02-01

    The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for all exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. The calculated mean percent difference between TLD measurements and Monte Carlo simulations was -4.9% with standard deviation of 8.7% and a range of -22.7% to 5.7%. The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.

  7. Barriers to Breast and Cervical Cancer Screening in Singapore: a Mixed Methods Analysis.

    PubMed

    Malhotra, Chetna; Bilger, Marcel; Liu, Joy; Finkelstein, Eric

    2016-01-01

    In order to increase breast and cervical cancer screening uptake in Singapore, women's perceived barriers to screening need to be identified and overcome. Using data from both focus groups and surveys, we aimed to assess perceived barriers and motivations for breast and cervical cancer screening. We conducted 8 focus groups with 64 women, using thematic analysis to identify overarching themes related to women's attitudes towards screening. Based on recurring themes from focus groups, several hypotheses regarding potential barriers and motivations to screen were generated and tested through a national survey of 801 women aged 25-64. Focus group participants had misconceptions related to screening, believing that the procedures were painful. Cost was an issue, as well as efficacy and fatalism. By identifying barriers to and motivators for screening through a mixed-method design that has both nuance and external validity, this study offers valuable suggestions to policymakers to improve breast and cervical cancer screening uptake in Singapore.

  8. Noninvasive methods for haemoglobin screening in prospective blood donors.

    PubMed

    Belardinelli, A; Benni, M; Tazzari, P L; Pagliaro, P

    2013-08-01

    The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening. Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (n = 445 donors) and by the Pronto-7 (Masimo) test (n = 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter). Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0.29 g/dl, the standard deviation of the differences (SDD) of 0.98 and 95% limits of agreement from -1.64 to 2.21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of -0.53 g/dl, SDD of 1.04 and 95% limits of agreement from -2.57 to 1.51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0.83 g/dl, SDD of 0.70 and 95% limits of agreement from -0.54 to 2.20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99.5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively. Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity. © 2013 International Society of Blood Transfusion.

  9. In-vivo imaging of retinal nerve fiber layer vasculature: imaging - histology comparison

    PubMed Central

    Scoles, Drew; Gray, Daniel C; Hunter, Jennifer J; Wolfe, Robert; Gee, Bernard P; Geng, Ying; Masella, Benjamin D; Libby, Richard T; Russell, Stephen; Williams, David R; Merigan, William H

    2009-01-01

    Background Although it has been suggested that alterations of nerve fiber layer vasculature may be involved in the etiology of eye diseases, including glaucoma, it has not been possible to examine this vasculature in-vivo. This report describes a novel imaging method, fluorescence adaptive optics (FAO) scanning laser ophthalmoscopy (SLO), that makes possible for the first time in-vivo imaging of this vasculature in the living macaque, comparing in-vivo and ex-vivo imaging of this vascular bed. Methods We injected sodium fluorescein intravenously in two macaque monkeys while imaging the retina with an FAO-SLO. An argon laser provided the 488 nm excitation source for fluorescence imaging. Reflectance images, obtained simultaneously with near infrared light, permitted precise surface registration of individual frames of the fluorescence imaging. In-vivo imaging was then compared to ex-vivo confocal microscopy of the same tissue. Results Superficial focus (innermost retina) at all depths within the NFL revealed a vasculature with extremely long capillaries, thin walls, little variation in caliber and parallel-linked structure oriented parallel to the NFL axons, typical of the radial peripapillary capillaries (RPCs). However, at a deeper focus beneath the NFL, (toward outer retina) the polygonal pattern typical of the ganglion cell layer (inner) and outer retinal vasculature was seen. These distinguishing patterns were also seen on histological examination of the same retinas. Furthermore, the thickness of the RPC beds and the caliber of individual RPCs determined by imaging closely matched that measured in histological sections. Conclusion This robust method demonstrates in-vivo, high-resolution, confocal imaging of the vasculature through the full thickness of the NFL in the living macaque, in precise agreement with histology. FAO provides a new tool to examine possible primary or secondary role of the nerve fiber layer vasculature in retinal vascular disorders and

  10. Magneto acoustic tomography with short pulsed magnetic field for in-vivo imaging of magnetic iron oxide nanoparticles.

    PubMed

    Mariappan, Leo; Shao, Qi; Jiang, Chunlan; Yu, Kai; Ashkenazi, Shai; Bischof, John C; He, Bin

    2016-04-01

    Nanoparticles are widely used as contrast and therapeutic agents. As such, imaging modalities that can accurately estimate their distribution in-vivo are actively sought. We present here our method Magneto Acoustic Tomography (MAT), which uses magnetomotive force due to a short pulsed magnetic field to induce ultrasound in the magnetic nanoparticle labeled tissue and estimates an image of the distribution of the nanoparticles in-vivo with ultrasound imaging resolution. In this study, we image the distribution of superparamagnetic iron oxide nanoparticles (IONP) using MAT method. In-vivo imaging was performed on live, nude mice with IONP injected into LNCaP tumors grown subcutaneously within the hind limb of the mice. Our experimental results indicate that the MAT method is capable of imaging the distribution of IONPs in-vivo. Therefore, MAT could become an imaging modality for high resolution reconstruction of MNP distribution in the body. Many magnetic nanoparticles (MNPs) have been used as contrast agents in magnetic resonance imaging. In this study, the authors investigated the use of ultrasound to detect the presence of MNPs by magneto acoustic tomography. In-vivo experiments confirmed the imaging quality of this new approach, which hopefully would provide an alternative method for accurate tumor detection. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Advancement of Analysis Method for Electromagnetic Screening Effect of Mountain Tunnel

    NASA Astrophysics Data System (ADS)

    Okutani, Tamio; Nakamura, Nobuyuki; Terada, Natsuki; Fukuda, Mitsuyoshi; Tate, Yutaka; Inada, Satoshi; Itoh, Hidenori; Wakao, Shinji

    In this paper we report advancement of an analysis method for electromagnetic screening effect of mountain tunnel with a multiple conductor circuit model. On A.C. electrified railways it is a great issue to manage the influence of electromagnetic induction caused by feeding circuits. Tunnels are said to have a screening effect to reduce the electromagnetic induction because a large amount of steel is used in the tunnels. But recently the screening effect is less expected because New Austrian Tunneling Method (NATM), in which the amount of steel used is less than in conventional methods, is adopted as the standard tunneling method for constructing mountain tunnels. So we measured and analyzed the actual screening effect of mountain tunnels constructed with NATM. In the process of the analysis we have advanced a method to analyze the screening effect more precisely. In this method we can adequately model tunnel structure as a part of multiple conductor circuit.

  12. Equity and practice issues in colorectal cancer screening: Mixed-methods study.

    PubMed

    Buchman, Sandy; Rozmovits, Linda; Glazier, Richard H

    2016-04-01

    To investigate overall colorectal cancer (CRC) screening rates, patterns in the use of types of CRC screening, and sociodemographic characteristics associated with CRC screening; and to gain insight into physicians' perceptions about and use of fecal occult blood testing [FOBT] and colonoscopy for patients at average risk of CRC. Mixed-methods study using cross-sectional administrative data on patient sociodemographic characteristics and semistructured telephone interviews with physicians. Toronto, Ont. Patients aged 50 to 74 years and physicians in family health teams in the Toronto Central Local Health Integration Network. Rates of CRC screening by type; sociodemographic characteristics associated with CRC screening; thematic analysis using constant comparative method for semistructured interviews. Ontario administrative data on CRC screening showed lower overall screening rates among those who were younger, male patients, those who had lower income, and recent immigrants. Colonoscopy rates were especially low among those with lower income and those who were recent immigrants. Semistructured interviews revealed that physician opinions about CRC screening for average-risk patients were divided: one group of physicians accepted the evidence and recommendations for FOBT and the other group of physicians strongly supported colonoscopy for these patients, believing that the FOBT was an inferior screening method. Physicians identified specialist recommendations and patient expectations as factors that influenced their decisions regarding CRC screening type. There was considerable variation in CRC screening by sociodemographic characteristics. A key theme that emerged from the interviews was that physicians were divided in their preference for FOBT or colonoscopy; factors that influenced physician preference included the health care system, recommendations by other specialists, and patient characteristics. Providing an informed choice of screening method to patients

  13. [Computerized monitoring for integrated cervical screening. Rationale, methods and indicators of participation].

    PubMed

    Bucchi, L; Pierri, C; Caprara, L; Cortecchia, S; De Lillo, M; Bondi, A

    2003-02-01

    This paper presents a computerised system for the monitoring of integrated cervical screening, i.e. the integration of spontaneous Pap smear practice into organised screening. The general characteristics of the system are described, including background and rationale (integrated cervical screening in European countries, impact of integration on monitoring, decentralised organization of screening and levels of monitoring), general methods (definitions, sections, software description, and setting of application), and indicators of participation (distribution by time interval since previous Pap smear, distribution by screening sector--organised screening centres vs public and private clinical settings--, distribution by time interval between the last two Pap smears, and movement of women between the two screening sectors). Also, the paper reports the results of the application of these indicators in the general database of the Pathology Department of Imola Health District in northern Italy.

  14. Evaluation of a standard test method for screening fuels in soils

    SciTech Connect

    Sorini, S.S.; Schabron, J.F.

    1996-12-31

    A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less

  15. Three screening methods for cognitive dysfunction using the Mini-Mental State Examination and Korean Dementia Screening Questionnaire.

    PubMed

    Choi, Seong Hye; Park, Moon Ho

    2016-02-01

    To screen for and determine cognitive dysfunction, cognitive tests and/or informant reports are commonly used. However, these cognitive tests and informant reports are not always available. The present study investigated three screening methods using the Mini-Mental State Examination (MMSE) as the cognitive test, and the Korean dementia screening questionnaire (KDSQ) as the informant report. Participants were recruited from the Korea Clinical Research Center for Dementia of South Korea, and included 2861 patients with Alzheimer's disease (dementia), 3519 patients with mild cognitive impairment and 1375 controls with no cognitive dysfunction. Three screening methods were tested: (i) MMSE alone (MMSE(cut-off) ); (ii) a conventional combination of MMSE and KDSQ (MMSE+KDSQ(cut-off) ); and (iii) a decision tree with MMSE and KDSQ (MMSE+KDSQ(decision tree) ). For discriminating any cognitive dysfunction from controls, MMSE+KDSQ(cut-off) had the highest area under the receiver operating characteristic curve (0.784). For discriminating dementia from controls, MMSE+KDSQ(cut-off) had the highest area under the receiver operating characteristic curve (0.899). For discriminating mild cognitive impairment from controls, MMSE(cut-off) had the highest area under the receiver operating characteristic curve (0.683). MMSE+KDSQ(decision tree) showed the highest sensitivity for all discriminations. For overall classification accuracy, MMSE+KDSQ(decision tree) had the highest value (70.0%). These three methods had different advantageous properties for screening and staging cognitive dysfunction. As there might be different availability across clinical settings, these three methods can be selected and used according to situational needs. © 2015 Japan Geriatrics Society.

  16. DEMONSTRATION BULLETIN: FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - U.S. ENVIRONMENTAL PROTECTION AGENCY

    EPA Science Inventory

    The field analytical screening program (FASP) polychlorinated biphenyl (PCB) method uses a temperature-programmable gas chromatograph (GC) equipped with an electron capture detector (ECD) to identify and quantify PCBs. Gas chromatography is an EPA-approved method for determi...

  17. High-throughput method for optimum solubility screening for homogeneity and crystallization of proteins

    DOEpatents

    Kim, Sung-Hou [Moraga, CA; Kim, Rosalind [Moraga, CA; Jancarik, Jamila [Walnut Creek, CA

    2012-01-31

    An optimum solubility screen in which a panel of buffers and many additives are provided in order to obtain the most homogeneous and monodisperse protein condition for protein crystallization. The present methods are useful for proteins that aggregate and cannot be concentrated prior to setting up crystallization screens. A high-throughput method using the hanging-drop method and vapor diffusion equilibrium and a panel of twenty-four buffers is further provided. Using the present methods, 14 poorly behaving proteins have been screened, resulting in 11 of the proteins having highly improved dynamic light scattering results allowing concentration of the proteins, and 9 were crystallized.

  18. Precision of a dry-chemistry method of lipid screening.

    PubMed

    Bowden, Rodney G; Kingery, Paul M; Long, Lindsey

    2006-06-01

    The purpose of this study was to compare total capillary cholesterol values acquired using the Reflotron with a venous sample taken simultaneously, to determine if the Reflotron meets the guidelines of the National Cholesterol Education Program (NCEP) for accuracy. An announcement and a registration form for a cholesterol screening programme were distributed with employee pay slips at a large southern university. Approximately 15 employees were scheduled for each screening date, with walk-ins allowed at the health assessment site as space allowed. Capillary and venous samples were collected from screening participants (n=285). Approximately 20 ml of blood was collected from each participant, after fasting for 12 h, using standardized venepuncture techniques in the antecubital vein in the bend of the elbow. In order to overcome technician error, two drops of blood (30 microl) were collected immediately from the previously drawn venous sample by drawing blood into the capillary tube from the opening in the top of the venous tube before centrifuging the venous sample, rather than 'sticking' the finger. A Kolmogorov-Smirnov (KS) test of normality was calculated for total capillary cholesterol (KS=1.27, P=0.79) and total venous cholesterol (KS=0.99, P=0.28), which revealed insufficient evidence that the distributions were not normal. Participants' total capillary cholesterol values averaged 213.27 mg/dl [standard deviation (SD)=44.66 mg/dl)] when analysed on the Reflotron, and slightly higher (228.86 mg/dl, SD=40.50 mg/dl) for venepuncture. A paired t-test for variance between groups revealed significant differences in total capillary and total venous cholesterol values (t=-41.93, P<0.0001). A mean centered coefficient of variation was performed, revealing a 3.3% error rate, i.e. greater than the 3% allowable by the NCEP III guidelines. The mean percent bias was -7.28% (SD=3.10%) and the absolute mean percent bias was 7.46% (SD=2.64%). The percentage of participants

  19. Evaluation of Quantitative Environmental Stress Screening (ESS) Methods. Volume 1

    DTIC Science & Technology

    1991-11-01

    required information on screening strength from the curvefitting parameters. The underlying theory and approach taken are discussed in Appendix A. To...in field 1020 arm St.,Vas AJ Ptr 0.4i Currpnt. c- ugt ~ing DU?/SYS 2.7264 Wll/IY.3 at Factory Stress- NaxiLMw outgoing W?is’ys 0.288 DrW/5?S at Field...182 125 K.W.Fertig and V.X. Murthy, Models for Reliability Growth During Burn-in: Theory and Applicat’ons,Proceedings 1978 Annual Reliability and

  20. Comparative analysis of machine learning methods in ligand-based virtual screening of large compound libraries.

    PubMed

    Ma, Xiao H; Jia, Jia; Zhu, Feng; Xue, Ying; Li, Ze R; Chen, Yu Z

    2009-05-01

    Machine learning methods have been explored as ligand-based virtual screening tools for facilitating drug lead discovery. These methods predict compounds of specific pharmacodynamic, pharmacokinetic or toxicological properties based on their structure-derived structural and physicochemical properties. Increasing attention has been directed at these methods because of their capability in predicting compounds of diverse structures and complex structure-activity relationships without requiring the knowledge of target 3D structure. This article reviews current progresses in using machine learning methods for virtual screening of pharmacodynamically active compounds from large compound libraries, and analyzes and compares the reported performances of machine learning tools with those of structure-based and other ligand-based (such as pharmacophore and clustering) virtual screening methods. The feasibility to improve the performance of machine learning methods in screening large libraries is discussed.

  1. Low-power adiabatic sequences for in-vivo localized two-dimensional chemical shift correlated MR spectroscopy

    PubMed Central

    Andronesi, Ovidiu C.; Ramadan, Saadallah; Mountford, Carolyn E.; Sorensen, A. Gregory

    2011-01-01

    Novel low-power adiabatic sequences are demonstrated for in-vivo localized two-dimensional (2D) correlated MR spectroscopy, such as COSY (Correlated Spectroscopy) and TOCSY (Total Correlated Spectroscopy). The design is based on three new elements for in-vivo 2D MRS: the use of gradient modulated constant adiabaticity GOIA-W(16,4) pulses for i) localization (COSY and TOCSY) and ii) mixing (TOCSY), and iii) the use of longitudinal mixing (z-filter) for magnetization transfer during TOCSY. GOIA-W(16,4) provides accurate signal localization, and more importantly, lowers the SAR for both TOCSY mixing and localization. Longitudinal mixing improves considerably (five-folds) the efficiency of TOCSY transfer. These are markedly different from previous 1D editing TOCSY sequences using spatially non-selective pulses and transverse mixing. Fully adiabatic (adiabatic mixing with adiabatic localization) and semi-adiabatic (adiabatic mixing with non-adiabatic localization) methods for 2D TOCSY are compared. Results are presented for simulations, phantoms, and in-vivo 2D spectra from healthy volunteers and patients with brain tumors obtained on 3T clinical platforms equipped with standard hardware. To the best of our knowledge this is the first demonstration of in-vivo adiabatic 2D TOCSY and fully adiabatic 2D COSY. It is expected that these methodological developments will advance the in-vivo applicability of multi(spectrally)dimensional MRS to reliably identify metabolic biomarkers. PMID:20890988

  2. Time-resolved luminescence screening method for enrofloxacin in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods currently used in the U.S. for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay ...

  3. Terbium-sensitized luminescence screening method for fluoroquinolones in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods commonly used for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay was developed...

  4. In-vivo analysis of ankle joint movement for patient-specific kinematic characterization.

    PubMed

    Ferraresi, Carlo; De Benedictis, Carlo; Franco, Walter; Maffiodo, Daniela; Leardini, Alberto

    2017-09-01

    In this article, a method for the experimental in-vivo characterization of the ankle kinematics is proposed. The method is meant to improve personalization of various ankle joint treatments, such as surgical decision-making or design and application of an orthosis, possibly to increase their effectiveness. This characterization in fact would make the treatments more compatible with the specific patient's joint physiological conditions. This article describes the experimental procedure and the analytical method adopted, based on the instantaneous and mean helical axis theories. The results obtained in this experimental analysis reveal that more accurate techniques are necessary for a robust in-vivo assessment of the tibio-talar axis of rotation.

  5. Automatic segmentation of vessels in in-vivo ultrasound scans

    NASA Astrophysics Data System (ADS)

    Tamimi-Sarnikowski, Philip; Brink-Kjær, Andreas; Moshavegh, Ramin; Arendt Jensen, Jørgen

    2017-03-01

    Ultrasound has become highly popular to monitor atherosclerosis, by scanning the carotid artery. The screening involves measuring the thickness of the vessel wall and diameter of the lumen. An automatic segmentation of the vessel lumen, can enable the determination of lumen diameter. This paper presents a fully automatic segmentation algorithm, for robustly segmenting the vessel lumen in longitudinal B-mode ultrasound images. The automatic segmentation is performed using a combination of B-mode and power Doppler images. The proposed algorithm includes a series of preprocessing steps, and performs a vessel segmentation by use of the marker-controlled watershed transform. The ultrasound images used in the study were acquired using the bk3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) with two transducers "8L2 Linear" and "10L2w Wide Linear" (BK Ultrasound, Herlev, Denmark). The algorithm was evaluated empirically and applied to a dataset of in-vivo 1770 images recorded from 8 healthy subjects. The segmentation results were compared to manual delineation performed by two experienced users. The results showed a sensitivity and specificity of 90.41+/-11.2 % and 97.93+/-5.7% (mean+/-standard deviation), respectively. The amount of overlap of segmentation and manual segmentation, was measured by the Dice similarity coefficient, which was 91.25+/-11.6%. The empirical results demonstrated the feasibility of segmenting the vessel lumen in ultrasound scans using a fully automatic algorithm.

  6. Method for screening inhibitors of the toxicity of Bacillus anthracis

    DOEpatents

    Cirino, Nick M.; Jackson, Paul J.; Lehnert, Bruce E.

    2001-01-01

    The protective antigen (PA) of Bacillus anthracis is integral to the mechanism of anthrax poisoning. The cloning, expression and purification of a 32 kDa B. anthracis PA fragment (PA32) is described. This fragment has also been expressed as a fusion construct to stabilized green fluorescent protein (EGFP-PA32). Both proteins were capable of binding to specific cell surface receptors as determined by fluorescent microscopy and a flow cytometric assay. To confirm binding specificity in the flow cytometric assay, non-fluorescent PA83 or PA32 was used to competitively inhibit fluorescent EGFP-PA32 binding to cell receptors. This assay can be employed as a rapid screen for compounds which disrupts binding of PA to cells. Additionally, the high intracellular expression levels and ease of purification make this recombinant protein an attractive vaccine candidate or therapeutic treatment for anthrax poisoning.

  7. Optical method for the screening of doping substances

    NASA Astrophysics Data System (ADS)

    Lademann, J.; Shevtsova, J.; Patzelt, A.; Richter, H.; Gladkowa, N. D.; Gelikonov, V. M.; Gonchukov, S. A.; Sterry, W.; Blume-Peytavi, U.

    2008-12-01

    During the last years, an increased misuse of doping substances in sport has been observed. The action of doping substances characterized by the stimulation of blood flow and metabolic processes is also reflected in the hair structure. In the present study it was demonstrated that optical coherent tomography is well suited for the analysis of hair parameters influenced by doping. Analyzing 20 patients, systemically treated with steroids which also represent doping substances, it was found that in all cases a significant increase in the cross-section of the hairs could be detected. The results obtained in the study are not only important for the screening of doping substances but also for medical diagnostics and control of compliance of patients.

  8. Correction for specimen movement and rotation errors for in-vivo Optical Projection Tomography

    PubMed Central

    Birk, Udo Jochen; Rieckher, Matthias; Konstantinides, Nikos; Darrell, Alex; Sarasa-Renedo, Ana; Meyer, Heiko; Tavernarakis, Nektarios; Ripoll, Jorge

    2010-01-01

    The application of optical projection tomography to in-vivo experiments is limited by specimen movement during the acquisition. We present a set of mathematical correction methods applied to the acquired data stacks to correct for movement in both directions of the image plane. These methods have been applied to correct experimental data taken from in-vivo optical projection tomography experiments in Caenorhabditis elegans. Successful reconstructions for both fluorescence and white light (absorption) measurements are shown. Since no difference between movement of the animal and movement of the rotation axis is made, this approach at the same time removes artifacts due to mechanical drifts and errors in the assumed center of rotation. PMID:21258448

  9. EVALUATION OF A FLUOROMETRIC SCREENING METHOD FOR PREDICTING TOTAL PAH CONCENTRATIONS IN CONTAMINATED SEDIMENTS

    EPA Science Inventory

    A flurorometric screening method was used to estimate total polycyclic aromatic hydrocarbon concentrations in sediments collected from the St. Louis River Area of Concern in northeastern Minnesota. Sediments were collected as part of a Regional Environmental Monitoring and Asses...

  10. Rapid automated method for screening of enteric pathogens from stool specimens.

    PubMed Central

    Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C

    1987-01-01

    A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230

  11. Using pre-screening methods for an effective and reliable site characterization at megasites.

    PubMed

    Algreen, Mette; Kalisz, Mariusz; Stalder, Marcel; Martac, Eugeniu; Krupanek, Janusz; Trapp, Stefan; Bartke, Stephan

    2015-10-01

    This paper illustrates the usefulness of pre-screening methods for an effective characterization of polluted sites. We applied a sequence of site characterization methods to a former Soviet military airbase with likely fuel and benzene, toluene, ethylbenzene, and xylene (BTEX) contamination in shallow groundwater and subsoil. The methods were (i) phytoscreening with tree cores; (ii) soil gas measurements for CH4, O2, and photoionization detector (PID); (iii) direct-push with membrane interface probe (MIP) and laser-induced fluorescence (LIF) sensors; (iv) direct-push sampling; and (v) sampling from soil and from groundwater monitoring wells. Phytoscreening and soil gas measurements are rapid and inexpensive pre-screening methods. Both indicated subsurface pollution and hot spots successfully. The direct-push sensors yielded 3D information about the extension and the volume of the subsurface plume. This study also expanded the applicability of tree coring to BTEX compounds and tested the use of high-resolution direct-push sensors for light hydrocarbons. Comparison of screening results to results from conventional soil and groundwater sampling yielded in most cases high rank correlation and confirmed the findings. The large-scale application of non- or low-invasive pre-screening can be of help in directing and focusing the subsequent, more expensive investigation methods. The rapid pre-screening methods also yielded useful information about potential remediation methods. Overall, we see several benefits of a stepwise screening and site characterization scheme, which we propose in conclusion.

  12. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    DOEpatents

    Warner, Benjamin P [Los Alamos, NM; Havrilla, George J [Los Alamos, NM; Miller, Thomasin C [Bartlesville, OK; Lewis, Cris [Los Alamos, NM; Mahan, Cynthia A [Los Alamos, NM; Wells, Cyndi A [Los Alamos, NM

    2009-04-14

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  13. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    DOEpatents

    Warner, Benjamin P [Los Alamos, NM; Havrilla, George J [Los Alamos, NM; Miller, Thomasin C [Bartlesville, OK; Lewis, Cris [Los Alamos, NM; Mahan, Cynthia A [Los Alamos, NM; Wells, Cyndi A [Los Alamos, NM

    2011-04-26

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  14. A Method for Screening Climate Change-Sensitive Infectious Diseases

    PubMed Central

    Wang, Yunjing; Rao, Yuhan; Wu, Xiaoxu; Zhao, Hainan; Chen, Jin

    2015-01-01

    Climate change is a significant and emerging threat to human health, especially where infectious diseases are involved. Because of the complex interactions between climate variables and infectious disease components (i.e., pathogen, host and transmission environment), systematically and quantitatively screening for infectious diseases that are sensitive to climate change is still a challenge. To address this challenge, we propose a new statistical indicator, Relative Sensitivity, to identify the difference between the sensitivity of the infectious disease to climate variables for two different climate statuses (i.e., historical climate and present climate) in non-exposure and exposure groups. The case study in Anhui Province, China has demonstrated the effectiveness of this Relative Sensitivity indicator. The application results indicate significant sensitivity of many epidemic infectious diseases to climate change in the form of changing climatic variables, such as temperature, precipitation and absolute humidity. As novel evidence, this research shows that absolute humidity has a critical influence on many observed infectious diseases in Anhui Province, including dysentery, hand, foot and mouth disease, hepatitis A, hemorrhagic fever, typhoid fever, malaria, meningitis, influenza and schistosomiasis. Moreover, some infectious diseases are more sensitive to climate change in rural areas than in urban areas. This insight provides guidance for future health inputs that consider spatial variability in response to climate change. PMID:25594780

  15. A method for screening climate change-sensitive infectious diseases.

    PubMed

    Wang, Yunjing; Rao, Yuhan; Wu, Xiaoxu; Zhao, Hainan; Chen, Jin

    2015-01-14

    Climate change is a significant and emerging threat to human health, especially where infectious diseases are involved. Because of the complex interactions between climate variables and infectious disease components (i.e., pathogen, host and transmission environment), systematically and quantitatively screening for infectious diseases that are sensitive to climate change is still a challenge. To address this challenge, we propose a new statistical indicator, Relative Sensitivity, to identify the difference between the sensitivity of the infectious disease to climate variables for two different climate statuses (i.e., historical climate and present climate) in non-exposure and exposure groups. The case study in Anhui Province, China has demonstrated the effectiveness of this Relative Sensitivity indicator. The application results indicate significant sensitivity of many epidemic infectious diseases to climate change in the form of changing climatic variables, such as temperature, precipitation and absolute humidity. As novel evidence, this research shows that absolute humidity has a critical influence on many observed infectious diseases in Anhui Province, including dysentery, hand, foot and mouth disease, hepatitis A, hemorrhagic fever, typhoid fever, malaria, meningitis, influenza and schistosomiasis. Moreover, some infectious diseases are more sensitive to climate change in rural areas than in urban areas. This insight provides guidance for future health inputs that consider spatial variability in response to climate change.

  16. Investigation of in-vivo skin autofluorescence lifetimes under long-term cw optical excitation

    SciTech Connect

    Lihachev, A; Ferulova, I; Vasiljeva, K

    2014-08-31

    The main results obtained during the last five years in the field of laser-excited in-vivo human skin photobleaching effects are presented. The main achievements and results obtained, as well as methods and experimental devices are briefly described. In addition, the impact of long-term 405-nm cw low-power laser excitation on the skin autofluorescence lifetime is experimentally investigated. (laser biophotonics)

  17. In-vivo measurement of lithium in the brain and other organs

    DOEpatents

    Vartsky, D.; Wielopolski, L.; LoMonte, A.F.; Ellis, K.J.; Cohn, S.H.

    1983-08-26

    An in-vivo method of measurement of the amount of lithium present in tissue and organs of breathing animals is described. The basis for the technique is the lithium-1 neutron interaction - /sup 6/Li(n,..cap alpha..)T. The lithium is irradiated with thermal neutrons to produce tritium atoms. The tritium diffuses into the tissues and is exhaled. By measuring the amount of tritium exhaled, the lithium concentration in the irradiated zone is determined.

  18. Cost-effectiveness analysis of colorectal cancer screening methods in Iran.

    PubMed

    Allameh, Zahra; Davari, Majid; Emami, Mohammad Hasan

    2011-03-01

    Screening can prevent colorectal cancer from becoming advanced by early detection of precancerous lesions. Cost-effectiveness analysis of colorectal cancer screening methods is highly necessary due to increased prevalence, decreased age at onset and the limited budget in Iran. Methods of screening currently available in Iran were selected. A systematic search revealed the sensitivity and specificity of each method. For this study, a model for a 20 year screening period of a population of 100,000 apparently healthy persons of ages 45-65 years in Isfahan Province was used. The cost-effectiveness of each method and the ratio of cost-effectiveness were calculated based on this model. The most and the least effective methods were CT colonography and fecal occult blood test, respectively. The highest and lowest expenditures in the governmental sector were related to fecal occult blood test and flexible sigmoidoscopy and in the private sector, to CT colonography and fecal occult blood test, respectively. The cost per cancer detected in 20 years of screening in the governmental sector was 0.28, 0.22 and 0.42 billion Rials, respectively for screening by colonoscopy, flexible sigmoidoscopy and fecal occult blood test. In the private sector, these were 1.54 (colonoscopy), 1.68 (flexible sigmoidoscopy), and 1.60 (fecal occult blood test) billion and 2.58 billion Rials for CT colonography, respectively. Although CT colonography is the most effective method, it needs a budget of 2.58 billion Rials for each screened patient. If costs in the governmental sector are considered, flexible sigmoidoscopy would be the most cost-effective method for screening the 45 - 65-year-old population in Iran.

  19. Development and evaluation of nursing user interface screens using multiple methods.

    PubMed

    Hyun, Sookyung; Johnson, Stephen B; Stetson, Peter D; Bakken, Suzanne

    2009-12-01

    Building upon the foundation of the Structured Narrative Electronic Health Record (EHR) model, we applied theory-based (combined Technology Acceptance Model and Task-Technology Fit Model) and user-centered methods to explore nurses' perceptions of functional requirements for an electronic nursing documentation system, design user interface screens reflective of the nurses' perspectives, and assess nurses' perceptions of the usability of the prototype user interface screens. The methods resulted in user interface screens that were perceived to be easy to use, potentially useful, and well-matched to nursing documentation tasks associated with Nursing Admission Assessment, Blood Administration, and Nursing Discharge Summary. The methods applied in this research may serve as a guide for others wishing to implement user-centered processes to develop or extend EHR systems. In addition, some of the insights obtained in this study may be informative to the development of safe and efficient user interface screens for nursing document templates in EHRs.

  20. Chemical Safety Alert: Identifying Chemical Reactivity Hazards Preliminary Screening Method

    EPA Pesticide Factsheets

    Introduces small-to-medium-sized facilities to a method developed by Center for Chemical Process Safety (CCPS), based on a series of twelve yes-or-no questions to help determine hazards in warehousing, repackaging, blending, mixing, and processing.

  1. Overview of Non-Volatile Testing and Screening Methods

    NASA Technical Reports Server (NTRS)

    Irom, Farokh

    2001-01-01

    Testing methods for memories and non-volatile memories have become increasingly sophisticated as they become denser and more complex. High frequency and faster rewrite times as well as smaller feature sizes have led to many testing challenges. This paper outlines several testing issues posed by novel memories and approaches to testing for radiation and reliability effects. We discuss methods for measurements of Total Ionizing Dose (TID).

  2. Continuous monitoring of haemoglobin concentration after in-vivo adjustment in patients undergoing surgery with blood loss.

    PubMed

    Frasca, D; Mounios, H; Giraud, B; Boisson, M; Debaene, B; Mimoz, O

    2015-07-01

    Non-invasive monitoring of haemoglobin concentration provides real-time measurement of haemoglobin concentration (SpHb) using multi-wavelength pulse co-oximetry. We hypothesised that in-vivo adjustment using the mean of three haemoglobinometer (HemoCue®) measurements from an arterial blood sample at the first SpHb measurement (HCueART) would increase the accuracy of the monitor. The study included 41 adults for a total of 173 measurements of haemoglobin concentration. In-vivo adjusted SpHb was automatically calculated by the following formula: in-vivo adjusted SpHb = unadjusted SpHb - (SpHb - HCueART). The accuracy of in-vivo adjusted SpHb was compared with SpHb retrospectively adjusted using the same formula, except for haemoglobin level which was assessed at the central laboratory and then compared with all other available invasive methods of haemoglobin measurement (co-oximetry, HbSAT; arterial HemoCue, HCueART; capillary HemoCue, HCueCAP). Compared with laboratory measurement of haemoglobin concentration, bias (precision) for unadjusted SpHb, in-vivo adjusted SpHb, retrospectively adjusted SpHb, HbSAT, HCueART and HCueCAP were -0.4 (1.4), -0.3 (1.1), -0.3 (1.1), -0.6 (0.7), 0.0 (0.4) and -0.5 (1.2) g.dl(-1) , respectively. In-vivo adjustment of SpHb values using the mean of three arterial HemoCue measurements improved the accuracy of the device similar to those observed after a retrospective adjustment using central laboratory haemoglobin level. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  3. Leaf water dynamics of Arabidopsis thaliana monitored in-vivo using terahertz time-domain spectroscopy

    NASA Astrophysics Data System (ADS)

    Castro-Camus, E.; Palomar, M.; Covarrubias, A. A.

    2013-10-01

    The declining water availability for agriculture is becoming problematic for many countries. Therefore the study of plants under water restriction is acquiring extraordinary importance. Botanists currently follow the dehydration of plants comparing the fresh and dry weight of excised organs, or measuring their osmotic or water potentials; these are destructive methods inappropriate for in-vivo determination of plants' hydration dynamics. Water is opaque in the terahertz band, while dehydrated biological tissues are partially transparent. We used terahertz spectroscopy to study the water dynamics of Arabidopsis thaliana by comparing the dehydration kinetics of leaves from plants under well-irrigated and water deficit conditions. We also present measurements of the effect of dark-light cycles and abscisic acid on its water dynamics. The measurements we present provide a new perspective on the water dynamics of plants under different external stimuli and confirm that terahertz can be an excellent non-contact probe of in-vivo tissue hydration.

  4. Who Gets the Job? First-Generation College Students' Perceptions of Employer Screening Methods

    ERIC Educational Resources Information Center

    Parks-Yancy, Rochelle; Cooley, Delonia

    2018-01-01

    What are first-generation college students' (FGCS) perspectives of employment screening methods? The authors investigate which methods FGCS believe are likely to cause an employer to extend a job offer and which methods yield the best pool of job applicants. Survey data were collected from undergraduate business majors. They were analyzed using…

  5. Eliciting women's cervical screening preferences: a mixed methods systematic review protocol.

    PubMed

    Wood, Brianne; Van Katwyk, Susan Rogers; El-Khatib, Ziad; McFaul, Susan; Taljaard, Monica; Wright, Erica; Graham, Ian D; Little, Julian

    2016-08-11

    With the accumulation of evidence regarding potential harms of cancer screening in recent years, researchers, policy-makers, and the public are becoming more critical of population-based cancer screening. Consequently, a high-quality cancer screening program should consider individuals' values and preferences when determining recommendations. In cervical cancer screening, offering women autonomy is considered a "person-centered" approach to health care services; however, it may impact the effectiveness of the program should women choose to not participate. As part of a larger project to investigate women's cervical screening preferences and correlates of these preferences, this systematic review will capture quantitative and qualitative investigations of women's cervical screening preferences and the methods used to elicit them. This mixed methods synthesis will use a thematic analysis approach to synthesize qualitative, quantitative, and mixed methods evidence. This protocol describes the methods that will be used in this investigation. A search strategy has been developed with a health librarian and peer reviewed using PRESS. Based on this strategy, five databases and the gray literature will be searched for studies that meet the inclusion criteria. The quality of the included individual studies will be examined using the Mixed Methods Appraisal Tool. Three reviewers will extract data from the primary studies on the tools or instruments used to elicit women's preferences regarding cervical cancer screening, theoretical frameworks used, outcomes measured, the outstanding themes from quantitative and qualitative evidence, and the identified preferences for cervical cancer screening. We will describe the relationships between study results and the study population, "intervention" (e.g., tool or instrument), and context. We will follow the PRISMA reporting guideline. We will compare findings across studies and between study methods (e.g., qualitative versus

  6. Measurement of Assertive Behavior: Construct and Predictive Validity of Self-Report, Role-Playing, and In-Vivo Measures.

    ERIC Educational Resources Information Center

    Burkhart, Barry R.

    1979-01-01

    Seventy-five subjects, who spanned the range of assertiveness, completed two self-report measures of assertiveness, eight role-playing situations involving positive and negative assertiveness, and a telephone in-vivo task. Correlations between the three measurement methods were examined. (Author/SJL)

  7. TINS, target immobilized NMR screening: an efficient and sensitive method for ligand discovery.

    PubMed

    Vanwetswinkel, Sophie; Heetebrij, Robert J; van Duynhoven, John; Hollander, Johan G; Filippov, Dmitri V; Hajduk, Philip J; Siegal, Gregg

    2005-02-01

    We propose a ligand screening method, called TINS (target immobilized NMR screening), which reduces the amount of target required for the fragment-based approach to drug discovery. Binding is detected by comparing 1D NMR spectra of compound mixtures in the presence of a target immobilized on a solid support to a control sample. The method has been validated by the detection of a variety of ligands for protein and nucleic acid targets (K(D) from 60 to 5000 muM). The ligand binding capacity of a protein was undiminished after 2000 different compounds had been applied, indicating the potential to apply the assay for screening typical fragment libraries. TINS can be used in competition mode, allowing rapid characterization of the ligand binding site. TINS may allow screening of targets that are difficult to produce or that are insoluble, such as membrane proteins.

  8. Field Screening Method for 2,4-Dinitrotoluene in Soil

    DTIC Science & Technology

    1991-10-01

    to be used for advertising or promotional purposes. Citation of brand names doesnot constitute an official endorsement or approval of the use of such... processed according to the tions of the protocols and results are shown in Table 8. method. After colordevelopment, four individuals were ANOVA...repeat process througho.: 30-minute pe- again for I minute. The solutions are filtered and the riod. absorbance read again at 570 nm. If 2,4-DNT is

  9. Intersection of Hazards and Pollution for Screening Methods

    EPA Pesticide Factsheets

    This layer combines the highest values of the CES, CEVA, and EJSM layers for hazard and pollution which is the burden component of the models. These models combine burden and vulnerability. This will allow viewers to see the overlap of hazard and pollution 00e2??hot spots00e2?? for each method without community figured in. This layer was created by James Sadd of Occidental College of Los Angeles

  10. Structural and optical characterization of NiSe film grown by screen-printing method

    NASA Astrophysics Data System (ADS)

    Sharma, Kapil; Sharma, D. K.; Dwivedi, D. K.; Kumar, Vipin

    2018-05-01

    In present investigation NiSe films were grown by economical screen-printing method. Optimum conditions for growing good quality screen-printed films were found. The films were characterized for their structural and optical properties. The polycrystalline nature of films with hexagonal structure was confirmed through XRD analysis. Direct type of optical band gap of 1.75 eV for the NiSe film was confirmed by optical characterization.

  11. A Comparison of Protein Kinases Inhibitor Screening Methods Using Both Enzymatic Activity and Binding Affinity Determination

    PubMed Central

    Rudolf, Amalie Frederikke; Skovgaard, Tine; Knapp, Stefan; Jensen, Lars Juhl; Berthelsen, Jens

    2014-01-01

    Binding assays are increasingly used as a screening method for protein kinase inhibitors; however, as yet only a weak correlation with enzymatic activity-based assays has been demonstrated. We show that the correlation between the two types of assays can be improved using more precise screening conditions. Furthermore a marked improvement in the correlation was found by using kinase constructs containing the catalytic domain in presence of additional domains or subunits. PMID:24915177

  12. A new mass screening method for methylmercury poisoning using mercury-volatilizing bacteria from Minamata Bay.

    PubMed

    Nakamura, K; Naruse, I; Takizawa, Y

    1999-09-01

    A simplified mass screening method for methylmercury exposure was developed using methylmercury-volatilizing bacteria from Minamata Bay. Some bacteria can transform methylmercury into mercury vapor. Most mercury in the hair is methylmercury, which is readily extracted with HCl solution. Black spots are formed on X-ray film due to the reduction of Ag(+) emulsion with mercury vapor produced by methylmercury-volatilizing bacteria. By exploiting these characteristics, a screening method was developed, whereby the fur of rats injected with methylmercury chloride formed clear black spots on X-ray film, whereas the fur of rats injected with saline did not. Subsequently, 50 human hair samples were examined using this mass screening method. The method identified people who had high mercury concentration, over 20 microg/g. A few thousand hair samples may be screened in a day using this method because it is rapid, simple, and economical. This method, therefore, enables screening of persons with methylmercury poisoning in mercury-polluted areas. Copyright 1999 Academic Press.

  13. Gastric Cancer Screening by Combined Determination of Serum Helicobacter pylori Antibody and Pepsinogen Concentrations: ABC Method for Gastric Cancer Screening.

    PubMed

    Chen, Xian-Zhe; Huang, Cheng-Zhi; Hu, Wei-Xian; Liu, Ying; Yao, Xue-Qing

    2018-05-20

    Gastroscopy combined with gastric mucosa biopsies is currently regarded as a gold standard for diagnosis of gastric cancer. However, its application is restricted in clinical practice due to its invasive property. A new noninvasive population screening process combining the assay of anti-Helicobacter pylori antibody and serum pepsinogen (PG) (ABC method) is adopted to recognize the high-risk patients for further endoscopy examination, avoiding the unnecessary gastroscopy for most population and saving the cost consumption for mass screening annually. Nevertheless, controversies exist for the grouping of ABC method and the intervals of gastroscopy surveillance for each group. In this review, we summarized these popular concerned topics for providing useful references to the healthcare practitioner in clinical practice. The PubMed databases were systematically searched from the inception dates to November 22, 2017, using the keywords "Helicobacter pylori," "Pepsinogens," and "Stomach Neoplasms." Original articles and reviews on the topics were selected. Anti-H. pylori antibody and serum PG concentration showed significant changes under the different status of H. pylori infection and the progression of atrophic gastritis, which can be used for risk stratification of gastric cancer in clinic. In addition, anti-H. pylori antibody titer can be used for further risk stratification of gastric cancer contributing to determine better endoscopy surveillance interval. The early detection and diagnosis of gastric cancer benefit from the risk stratification, but the cutoff values for H. pylori antibody and serum PG concentration require further modification.

  14. Recruitment methods employed in the prostate, lung, colorectal, and ovarian cancer screening trial

    PubMed Central

    Gren, Lisa; Broski, Karen; Childs, Jeffery; Cordes, Jill; Engelhard, Deborah; Gahagan, Betsy; Gamito, Eduard; Gardner, Vivien; Geisser, Mindy; Higgins, Darlene; Jenkins, Victoria; Lamerato, Lois; Lappe, Karen; Lowery, Heidi; McGuire, Colleen; Miedzinski, Mollie; Ogden, Sheryl; Tenorio, Sally; Watt, Gavin; Wohlers, Bonita; Marcus, Pamela

    2015-01-01

    Background The Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial (PLCO) is a US National Cancer Institute (NCI)-funded randomized controlled trial designed to evaluate whether certain screening tests reduce mortality from prostate, lung, colorectal, and ovarian cancer. To obtain adequate statistical power, it was necessary to enroll over 150,000 healthy volunteers. Recruitment began in 1993 and ended in 2001. Purpose Our goal is to evaluate the success of recruitment methods employed by the 10 PLCO screening centers. We also provide estimates of recruitment yield and cost for our most successful strategy, direct mail. Methods Each screening center selected its own methods of recruitment. Methods changed throughout the recruitment period as needed. For this manuscript, representatives from each screening center provided information on methods utilized and their success. Results In the United States between 1993 and 2001, ten screening centers enrolled 154,934 study participants. Based on participant self-report, an estimated 95% of individuals were recruited by direct mail. Overall, enrollment yield for direct mail was 1.0%. Individual center enrollment yield ranged from 0.7% to 3.8%. Cost per enrolled participant was $9.64–35.38 for direct mail, excluding personnel costs. Limitations Numeric data on recruitment processes were not kept consistently at individual screening centers. Numeric data in this manuscript are based on the experiences of 5 of the 10 centers. Conclusions Direct mail, using rosters of names and addresses from profit and not-for-profit (including government) organizations, was the most successful and most often used recruitment method. Other recruitment strategies, such as community outreach and use of mass media, can be an important adjunct to direct mail in recruiting minority populations. PMID:19254935

  15. A method for screening of plant species for space use

    NASA Technical Reports Server (NTRS)

    Goeschl, J. D.; Sauer, R. L.; Scheld, H. W.

    1986-01-01

    A cost-effective methodology which monitors numerous dynamic aspects of carbon assimilation and allocation kinetics in live, intact plants is discussed. Analogous methods can apply to nitrogen uptake and allocation. This methodology capitalizes on the special properties of the short-lived, positron-gamma emitting isotope C-11 especially when applied as CO2-11 in a special extended square wave (ESW) pattern. The 20.4 minute half-life allows for repeated or continuous experiments on the same plant over periods of minutes, hours, days, or weeks. The steady-state isotope equilibrium approached during the ESW experiments, and the parameters which can be analyzed by this technique are also direct results of that short half-life. Additionally, the paired .511 MeV gamma rays penetrate any amount of tissue and their 180 deg opposite orientation provides good collimation and allows coincidence counting which nearly eliminates background.

  16. A NOVEL WEARABLE PUMP-LUNG DEVICE: IN-VITRO AND ACUTE IN-VIVO STUDY

    PubMed Central

    Zhang, Tao; Wei, Xufeng; Bianchi, Giacomo; Wong, Philip M.; Biancucci, Brian; Griffith, Bartley P.; Wu, Zhongjun J.

    2011-01-01

    Background To provide long-term ambulatory cardiopulmonary and respiratory support for adult patients, a novel wearable artificial pump-lung device has been developed. The design features, in-vitro and acute in-vivo performance of this device are reported in this paper. Methods This device features a uniquely designed hollow fiber membrane bundle integrated with a magnetically levitated impeller together to form one ultra-compact pump-lung device, which can be placed like current paracorporeal ventricular assist devices to allow ambulatory support. The device is 117 mm in length and 89 mm in diameter and has a priming volume of 115 ml. In-vitro hydrodynamic, gas transfer and biocompatibility experiments were carried out in mock flow loops using ovine blood. Acute in-vivo characterization was conducted in ovine by surgically implanting the device between right atrium and pulmonary artery. Results The in-vitro results showed that the device with a membrane surface area of 0.8 m2 was capable of pumping blood from 1 to 4 L/min against a wide range of pressures and transferring oxygen at a rate of up to 180 ml/min at a blood flow of 3.5 L/min. Standard hemolysis tests demonstrated low hemolysis at the targeted operating condition. The acute in-vivo results also confirmed that the device can provide sufficient oxygen transfer with excellent biocompatibility. Conclusions Base on the in-vitro and acute in-vivo study, this highly integrated wearable pump-lung device can provide efficient respiratory support with good biocompatibility and it is ready for long-term evaluation. PMID:22014451

  17. Novel method for screening of enteric film coatings properties with magnetic resonance imaging.

    PubMed

    Dorożyński, Przemysław; Jamróz, Witold; Niwiński, Krzysztof; Kurek, Mateusz; Węglarz, Władysław P; Jachowicz, Renata; Kulinowski, Piotr

    2013-11-18

    The aim of the study is to present the concept of novel method for fast screening of enteric coating compositions properties without the need of preparation of tablets batches for fluid bed coating. Proposed method involves evaluation of enteric coated model tablets in specially designed testing cell with application of MRI technique. The results obtained in the testing cell were compared with results of dissolution studies of mini-tablets coated in fluid bed apparatus. The method could be useful in early stage of formulation development for screening of film coating properties that will shorten and simplify the development works. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. A virtual screening method for inhibitory peptides of Angiotensin I-converting enzyme.

    PubMed

    Wu, Hongxi; Liu, Yalan; Guo, Mingrong; Xie, Jingli; Jiang, XiaMin

    2014-09-01

    Natural small peptides from foods have been proven to be efficient inhibitors of Angiotensin I-converting enzyme (ACE) for the regulation of blood pressure. The traditional ACE inhibitory peptides screening method is both time consuming and money costing, to the contrary, virtual screening method by computation can break these limitations. We establish a virtual screening method to obtain ACE inhibitory peptides with the help of Libdock module of Discovery Studio 3.5 software. A significant relationship between Libdock score and experimental IC(50) was found, Libdock score = 10.063 log(1/IC(50)) + 68.08 (R(2) = 0.62). The credibility of the relationship was confirmed by testing the coincidence of the estimated log(1/IC(50)) and measured log(1/IC(50)) (IC(50) is 50% inhibitory concentration toward ACE, in μmol/L) of 5 synthetic ACE inhibitory peptides, which was virtual hydrolyzed and screened from a kind of seafood, Phascolosoma esculenta. Accordingly, Libdock method is a valid IC(50) estimation tool and virtual screening method for small ACE inhibitory peptides. © 2014 Institute of Food Technologists®

  19. Hazard Screening Methods for Nanomaterials: A Comparative Study

    PubMed Central

    Murphy, Finbarr; Mullins, Martin; Furxhi, Irini; Costa, Anna L.; Simeone, Felice C.

    2018-01-01

    Hazard identification is the key step in risk assessment and management of manufactured nanomaterials (NM). However, the rapid commercialisation of nano-enabled products continues to out-pace the development of a prudent risk management mechanism that is widely accepted by the scientific community and enforced by regulators. However, a growing body of academic literature is developing promising quantitative methods. Two approaches have gained significant currency. Bayesian networks (BN) are a probabilistic, machine learning approach while the weight of evidence (WoE) statistical framework is based on expert elicitation. This comparative study investigates the efficacy of quantitative WoE and Bayesian methodologies in ranking the potential hazard of metal and metal-oxide NMs—TiO2, Ag, and ZnO. This research finds that hazard ranking is consistent for both risk assessment approaches. The BN and WoE models both utilize physico-chemical, toxicological, and study type data to infer the hazard potential. The BN exhibits more stability when the models are perturbed with new data. The BN has the significant advantage of self-learning with new data; however, this assumes all input data is equally valid. This research finds that a combination of WoE that would rank input data along with the BN is the optimal hazard assessment framework. PMID:29495342

  20. Fingerprints: A simple method for Screening Hemophilic Patients.

    PubMed

    Jamalian, M; Mesri, M; Vishteh, H R K; Solhi, H; Salehpour, R

    2014-08-01

    The present study aims to compare hemophilic patients' fingerprint types with the normal people to help diagnose the disease, particularly new occurrences of the disease. This case-control study was conducted in 2012. Sixty two patients with hemophilia type A and 62 normal healthy people were selected. The type of fingerprint was determined by a forensic specialist who was kept unaware of the participants' group. Using advanced Henry method, the main types of fingerprints were classified as arch, loop, whorl, as well as other types. In the control group, loop type (65%) and in the case group the whorl type (34%) were the most frequent fingerprint type (p < 0.001) and there was a significant difference of fingerprint in each finger between two groups. In addition, the average number of whorl type in the patients with mild disease was significantly higher and the average number of arch and other types of fingerprints was significantly lower than patients with moderate or severe disease. The findings of the present study indicated that not only are the fingerprints of normal and hemophilic people different, but also a difference was observed between hemophilic patients with the mild factor level and patients with moderate or severe one.

  1. A small-bolt method for screening tree protectants against bark beetles (coleoptera: curculionidae)

    Treesearch

    B.L. Strom; L.M. Roton

    2009-01-01

    A simple, small-bolt method was developed and refi ned for evaluating and screening treatments being considered as prophylactics against bark beetles (Coleoptera: Curculionidae: Scolytinae). Using this method, 4 insecticide products (3 active ingredients) were evaluated against the southern pine beetle, Dendroctonus frontalis Zimmermann, intermittently during a period...

  2. Recommendations for Developing Alternative Test Methods for Screening and Prioritization of Chemicals for Developmental Neurotoxicity

    EPA Science Inventory

    Developmental neurotoxicity testing (DNT) is perceived by many stakeholders to be an area in critical need of alternative methods to current animal testing protocols and gUidelines. An immediate goal is to develop test methods that are capable of screening large numbers of chemic...

  3. Disposable Fluidic Actuators for Miniature In-Vivo Surgical Robotics.

    PubMed

    Pourghodrat, Abolfazl; Nelson, Carl A

    2017-03-01

    Fusion of robotics and minimally invasive surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems to miniature in-vivo robotics. However, with miniaturization of electric-motor-driven surgical robots, there comes a trade-off between the size of the robot and its capability. Slow actuation, low load capacity, sterilization difficulties, leaking electricity and transferring produced heat to tissues, and high cost are among the key limitations of the use of electric motors in in-vivo applications. Fluid power in the form of hydraulics or pneumatics has a long history in driving many industrial devices and could be exploited to circumvent these limitations. High power density and good compatibility with the in-vivo environment are the key advantages of fluid power over electric motors when it comes to in-vivo applications. However, fabrication of hydraulic/pneumatic actuators within the desired size and pressure range required for in-vivo surgical robotic applications poses new challenges. Sealing these types of miniature actuators at operating pressures requires obtaining very fine surface finishes which is difficult and costly. The research described here presents design, fabrication, and testing of a hydraulic/pneumatic double-acting cylinder, a limited-motion vane motor, and a balloon-actuated laparoscopic grasper. These actuators are small, seal-less, easy to fabricate, disposable, and inexpensive, thus ideal for single-use in-vivo applications. To demonstrate the ability of these actuators to drive robotic joints, they were modified and integrated in a robotic arm. The design and testing of this surgical robotic arm are presented to validate the concept of fluid-power actuators for in-vivo applications.

  4. Disposable Fluidic Actuators for Miniature In-Vivo Surgical Robotics

    PubMed Central

    Pourghodrat, Abolfazl; Nelson, Carl A.

    2017-01-01

    Fusion of robotics and minimally invasive surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems to miniature in-vivo robotics. However, with miniaturization of electric-motor-driven surgical robots, there comes a trade-off between the size of the robot and its capability. Slow actuation, low load capacity, sterilization difficulties, leaking electricity and transferring produced heat to tissues, and high cost are among the key limitations of the use of electric motors in in-vivo applications. Fluid power in the form of hydraulics or pneumatics has a long history in driving many industrial devices and could be exploited to circumvent these limitations. High power density and good compatibility with the in-vivo environment are the key advantages of fluid power over electric motors when it comes to in-vivo applications. However, fabrication of hydraulic/pneumatic actuators within the desired size and pressure range required for in-vivo surgical robotic applications poses new challenges. Sealing these types of miniature actuators at operating pressures requires obtaining very fine surface finishes which is difficult and costly. The research described here presents design, fabrication, and testing of a hydraulic/pneumatic double-acting cylinder, a limited-motion vane motor, and a balloon-actuated laparoscopic grasper. These actuators are small, seal-less, easy to fabricate, disposable, and inexpensive, thus ideal for single-use in-vivo applications. To demonstrate the ability of these actuators to drive robotic joints, they were modified and integrated in a robotic arm. The design and testing of this surgical robotic arm are presented to validate the concept of fluid-power actuators for in-vivo applications. PMID:28070227

  5. [Screening for risk of child abuse and neglect. A practicable method?].

    PubMed

    Kindler, H

    2010-10-01

    Selective primary prevention programs for child abuse and neglect depend on risk screening instruments that have the goal of systematically identifying families who can profit most from early help. Based on a systematic review of longitudinal studies, a set of established risk factors for early child abuse and neglect is presented. Nearly half of the items included in screening instruments can be seen as validated. Available studies indicate a high sensitivity of risk screening instruments. Positive predictive values, however, are low. Overall, the use of risk screening instruments in the area of primary prevention for families at risk represents a feasible method, as long as stigmatizing effects can be avoided and participating families also benefit beyond preventing endangerment.

  6. Anthropometric methods for obesity screening in schoolchildren: the Ouro Preto Study.

    PubMed

    Cándido, A P C; Alosta, J P S; Oliveira, C T; Freitas, R N; Freitas, S N; Machado-Coelho, G L L

    2012-01-01

    Childhood obesity is increasing dramatically in last decades. To evaluate the usefulness of body mass index (BMI), skinfold thickness (ST), waist circumference (WC), and foot-to-foot bioelectrical impedance (BIA-FF) for screening for obesity in mixed-race population, using the tetrapolar bioelectrical impedance (BIA-T) technique as reference method. A cross-sectional-based population study was performed in the city of Ouro Preto, Brazil, in 2006. Schoolchildren aged 6-15 years (n = 788) was randomly selected according to age and sex stratified by the proportion of students in each schools of the city. Nonparametric receiver operating characteristic (ROC) analysis was used to define the sensitivity and specificity for each method studied using the tetrapolar method as reference. The BMI and the BIA-FF were the most suitable for adiposity screening in pre-pubertal and pubertal stages because they present a better balance between sensitivity and specificity, and smaller misclassification. For post-pubertal boys, the BF-ST-D was the best body fat assessment method. The results suggest that BIA-FF and BMI are choice methods for obesity screening in mixed population and that the method choice for body fat screening must be done according to sexual maturity of boys and girls. The present study demonstrates the need to perform studies in wider mixed-race population to determine anthropometric parameters and to examine the predictive ability of methods and cut-offs here elucidated in the development of obesity.

  7. Comparative Evaluation of Preliminary Screening Methods for Colorectal Cancer in a Mass Program.

    PubMed

    Ye, Ding; Huang, Qiuchi; Li, Qilong; Jiang, Xiyi; Mamat, Mayila; Tang, Mengling; Wang, Jianbing; Chen, Kun

    2017-09-01

    The fecal immunochemical test (FIT) has been widely used in preliminary screening for colorectal cancer (CRC). The high-risk factor questionnaire (HRFQ) and quantitative risk-assessment method (QRAM) are recommended for estimating the risk of CRC qualitatively and quantitatively in China. We aimed to prospectively compare the diagnostic values of CRC preliminary screening methods to identify which method is preferable as a screening strategy. Individuals aged 40-74 years old were enrolled in a mass CRC screening program from January 1, 2007 to December 31, 2014, in Jiashan County, Zhejiang Province, China. FIT of two stool specimens at 1-week intervals was performed by laboratory personnel and face-to-face interviews were conducted by trained investigators. Screening data in the program were linked to a CRC surveillance and registry system, and CRC cases reported in the system were regarded as true patients. A total of 96,043 subjects were included. The sensitivity and specificity of FIT for detecting CRC cases were 75.49% (95% CI 69.84-80.39) and 90.36% (95% CI 90.17-90.54), respectively. QRAM was more sensitive (p < 0.001) and less specific (p < 0.001) than HRFQ. The sensitivity and specificity of FIT along with HRFQ were 86.56% (95% CI 81.81-90.22) and 81.37% (95% CI 81.12-81.62), and those of FIT along with QRAM were 88.93% (95% CI 84.47-92.23) and 73.95% (95% CI 73.67-74.23). Our findings suggest that CRC preliminary screening with FIT and QRAM in parallel has high sensitivity and satisfactory specificity, and is a useful strategy in mass screening programs.

  8. Experimental cocrystal screening and solution based scale-up cocrystallization methods.

    PubMed

    Malamatari, Maria; Ross, Steven A; Douroumis, Dennis; Velaga, Sitaram P

    2017-08-01

    Cocrystals are crystalline single phase materials composed of two or more different molecular and/or ionic compounds generally in a stoichiometric ratio which are neither solvates nor simple salts. If one of the components is an active pharmaceutical ingredient (API), the term pharmaceutical cocrystal is often used. There is a growing interest among drug development scientists in exploring cocrystals, as means to address physicochemical, biopharmaceutical and mechanical properties and expand solid form diversity of the API. Conventionally, coformers are selected based on crystal engineering principles, and the equimolar mixtures of API and coformers are subjected to solution-based crystallization that are commonly employed in polymorph and salt screening. However, the availability of new knowledge on cocrystal phase behaviour in solid state and solutions has spurred the development and implementation of more rational experimental cocrystal screening as well as scale-up methods. This review aims to provide overview of commonly employed solid form screening techniques in drug development with an emphasis on cocrystal screening methodologies. The latest developments in understanding and the use of cocrystal phase diagrams in both screening and solution based scale-up methods are also presented. Final section is devoted to reviewing the state of the art research covering solution based scale-up cocrystallization process for different cocrystals besides more recent continuous crystallization methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Reverse screening methods to search for the protein targets of chemopreventive compounds

    NASA Astrophysics Data System (ADS)

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-05-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and

  10. Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds

    PubMed Central

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-01-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn

  11. Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds.

    PubMed

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-01-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn

  12. Screening methods for post-stroke visual impairment: a systematic review.

    PubMed

    Hanna, Kerry Louise; Hepworth, Lauren Rachel; Rowe, Fiona

    2017-12-01

    assess all potential post-stroke visual impairments. The current tools screen for only a number of potential stroke-related impairments, which means many visual defects may be missed. The sensitivity of those which screen for all impairments is significantly lowered when patients are unable to report their visual symptoms. Future research is required to develop a tool capable of assessing stroke patients which encompasses all potential visual deficits and can also be easily performed by both the patients and administered by health care professionals in order to ensure all stroke survivors with visual impairment are accurately identified and managed. Implications for Rehabilitation Over 65% of stroke survivors will suffer from a visual impairment, whereas 45% of stroke units do not assess vision. Visual impairment significantly reduces the quality of life, such as being unable to return to work, driving and depression. This review outlines the available screening methods to accurately identify stroke survivors with visual impairments. Identifying visual impairment after stroke can aid general rehabilitation and thus, improve the quality of life for these patients.

  13. In-Vivo Human Skin to Textiles Friction Measurements

    NASA Astrophysics Data System (ADS)

    Pfarr, Lukas; Zagar, Bernhard

    2017-10-01

    We report on a measurement system to determine highly reliable and accurate friction properties of textiles as needed for example as input to garment simulation software. Our investigations led to a set-up that allows to characterize not just textile to textile but also textile to in-vivo human skin tribological properties and thus to fundamental knowledge about genuine wearer interaction in garments. The method of test conveyed in this paper is measuring concurrently and in a highly time resolved manner the normal force as well as the resulting shear force caused by a friction subject intending to slide out of the static friction regime and into the dynamic regime on a test bench. Deeper analysis of various influences is enabled by extending the simple model following Coulomb's law for rigid body friction to include further essential parameters such as contact force, predominance in the yarn's orientation and also skin hydration. This easy-to-use system enables to measure reliably and reproducibly both static and dynamic friction for a variety of friction partners including human skin with all its variability there might be.

  14. Evaluation of Nurses' Acceptance of Screen Display Methods with Temporarily Non-Display for Privacy Protection.

    PubMed

    Niimi, Yukari; Ota, Katsumasa; Ikegami, Chikako

    2018-01-01

    The purpose of this study was to explore nurses' acceptance of a screen display method that temporarily hides patient information for privacy protection. Using a questionnaire, we asked nurses to evaluate the display method from the viewpoints of safety and efficiency with respect to 22 personal information items. The nurses were favorably interested in introducing the display method into their hospital system; however, their acceptance varied.

  15. Proposal of Screening Method of Sleep Disordered Breathing Using Fiber Grating Vision Sensor

    NASA Astrophysics Data System (ADS)

    Aoki, Hirooki; Nakamura, Hidetoshi; Nakajima, Masato

    Every conventional respiration monitoring technique requires at least one sensor to be attached to the body of the subject during measurement, thereby imposing a sense of restraint that results in aversion against measurements that would last over consecutive days. To solve this problem, we developed a respiration monitoring system for sleepers, and it uses a fiber-grating vision sensor, which is a type of active image sensor to achieve non-contact respiration monitoring. In this paper, we verified the effectiveness of the system, and proposed screening method of the sleep disordered breathing. It was shown that our system could equivalently measure the respiration with thermistor and accelerograph. And, the respiratory condition of sleepers can be grasped by our screening method in one look, and it seems to be useful for the support of the screening of sleep disordered breathing.

  16. A comparative rapid and sensitive method to screen l-asparaginase producing fungi.

    PubMed

    Dhale, Mohan A; Mohan-Kumari, H Puttananjaiah

    2014-07-01

    Fungi are well known to produce various industrial enzymes and secondary metabolites with different colours. Fungi producing l-asparaginase enzyme are conventionally screened on medium containing phenol red (PR). The contrast between enzyme-hydrolysed zone and unhydrolysed l-asparagine is not very evident and distinct in medium containing PR and bromothymol blue (BB) due to coloured secondary metabolite production. Thus, PR and BB limit and affect the detection and screening method. In the present investigation, an improved method for screening is reported by comparing with PR and BB, wherein methyl red (MR) is incorporated as pH indicator. The enzyme activity was distinctly observed (red and light-yellow) in MR incorporated medium compared to PR and BB. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. A new screening method for amphetamine and methamphetamine using dansyl chloride derivatization and cartridge fluorescence.

    PubMed

    Yamada, H; Ikeda-Wada, S; Oguri, K

    1998-07-01

    A new screening method for amphetamines was developed. It consists of derivatization with dansyl chloride, extraction of the derivative using a Sep-Pak C18 or a Bond Elut C18, solid phase extraction columns, and visualization of the fluorescence of the cartridge. A control test using drug-free urine showed no fluorescence. Amphetamine, methamphetamine and the methylenedioxy derivatives exhibited strong fluorescence, while related compounds, such as N-ethylamphetamine and fenetylline, were negative or weakly positive. The disadvantage of the present method is that it is a multi-step procedure and 20-30 min is required for screening. However, since it has a different specificity from the widely used immunochemical technique, it is suggested to be a useful screen for amphetamines.

  18. Newborn screening for cystic fibrosis in Wisconsin: comparison of biochemical and molecular methods.

    PubMed

    Gregg, R G; Simantel, A; Farrell, P M; Koscik, R; Kosorok, M R; Laxova, A; Laessig, R; Hoffman, G; Hassemer, D; Mischler, E H; Splaingard, M

    1997-06-01

    To evaluate neonatal screening for cystic fibrosis (CF), including study of the screening procedures and characteristics of false-positive infants, over the past 10 years in Wisconsin. An important objective evolving from the original design has been to compare use of a single-tier immunoreactive trypsinogen (IRT) screening method with that of a two-tier method using IRT and analyses of samples for the most common cystic fibrosis transmembrane regulator (CFTR) (DeltaF508) mutation. We also examined the benefit of including up to 10 additional CFTR mutations in the screening protocol. From 1985 to 1994, using either the IRT or IRT/DNA protocol, 220 862 and 104 308 neonates, respectively, were screened for CF. For the IRT protocol, neonates with an IRT >/=180 ng/mL were considered positive, and the standard sweat chloride test was administered to determine CF status. For the IRT/DNA protocol, samples from the original dried-blood specimen on the Guthrie card of neonates with an IRT >/=110 ng/mL were tested for the presence of the DeltaF508 CFTR allele, and if the DNA test revealed one or two DeltaF508 alleles, a sweat test was obtained. Both screening procedures had very high specificity. The sensitivity tended to be higher with the IRT/DNA protocol, but the differences were not statistically significant. The positive predictive value of the IRT/DNA screening protocol was 15.2% compared with 6.4% if the same samples had been screened by the IRT method. Assessment of the false-positive IRT/DNA population revealed that the two-tier method eliminates the disproportionate number of infants with low Apgar scores and also the high prevalence of African-Americans identified previously in our study of newborns with high IRT levels. We found that 55% of DNA-positive CF infants were homozygous for DeltaF508 and 40% had one DeltaF508 allele. Adding analyses for 10 more CFTR mutations has only a small effect on the sensitivity but is likely to add significantly to the cost of

  19. Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.

    PubMed

    Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G

    2017-08-01

    Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.

  20. One Question, Multiple Answers: Biochemical and Biophysical Screening Methods Retrieve Deviating Fragment Hit Lists.

    PubMed

    Schiebel, Johannes; Radeva, Nedyalka; Köster, Helene; Metz, Alexander; Krotzky, Timo; Kuhnert, Maren; Diederich, Wibke E; Heine, Andreas; Neumann, Lars; Atmanene, Cedric; Roecklin, Dominique; Vivat-Hannah, Valérie; Renaud, Jean-Paul; Meinecke, Robert; Schlinck, Nina; Sitte, Astrid; Popp, Franziska; Zeeb, Markus; Klebe, Gerhard

    2015-09-01

    Fragment-based lead discovery is gaining momentum in drug development. Typically, a hierarchical cascade of several screening techniques is consulted to identify fragment hits which are then analyzed by crystallography. Because crystal structures with bound fragments are essential for the subsequent hit-to-lead-to-drug optimization, the screening process should distinguish reliably between binders and non-binders. We therefore investigated whether different screening methods would reveal similar collections of putative binders. First we used a biochemical assay to identify fragments that bind to endothiapepsin, a surrogate for disease-relevant aspartic proteases. In a comprehensive screening approach, we then evaluated our 361-entry library by using a reporter-displacement assay, saturation-transfer difference NMR, native mass spectrometry, thermophoresis, and a thermal shift assay. While the combined results of these screening methods retrieve 10 of the 11 crystal structures originally predicted by the biochemical assay, the mutual overlap of individual hit lists is surprisingly low, highlighting that each technique operates on different biophysical principles and conditions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. An extension of the Coconut Cream Agar method to screen Penicillium citrinum isolates for citrinin production.

    PubMed

    Mohamed, S; Flint, S; Palmer, J; Fletcher, G C; Pitt, J I

    2013-09-01

    A simple and rapid screening method was developed for the detection of citrinin in fungal cultures using Coconut Cream Agar (CCA) described previously for detecting aflatoxin and ochratoxin A. Fifteen isolates of Penicillium citrinum were inoculated onto CCA and incubated at 25 and 30°C for 10 days. All isolates produced a distinct yellow green fluorescence on CCA when the reverse side of the agar plates were viewed under long wavelength UV light. Detection was optimal at 25°C after four to 5 days of incubation. Isolates positive by the CCA method also tested positive for citrinin production by the TLC agar plug method after growth on CCA, Czapek yeast extract agar and yeast extract sucrose agar. Control cultures were negative by both methods, indicating that the CCA Petri dish method was suitable for screening cultures for citrinin production. © 2013 The Society for Applied Microbiology.

  2. WE-E-18A-04: Precision In-Vivo Dosimetry Using Optically Stimulated Luminescence Dosimeters and a Pulsed-Stimulating Dose Reader

    SciTech Connect

    Chen, Q; Herrick, A; Hoke, S

    Purpose: A new readout technology based on pulsed optically stimulating luminescence is introduced (microSTARii, Landauer, Inc, Glenwood, IL60425). This investigation searches for approaches that maximizes the dosimetry accuracy in clinical applications. Methods: The sensitivity of each optically stimulated luminescence dosimeter (OSLD) was initially characterized by exposing it to a given radiation beam. After readout, the luminescence signal stored in the OSLD was erased by exposing its sensing area to a 21W white LED light for 24 hours. A set of OSLDs with consistent sensitivities was selected to calibrate the dose reader. Higher order nonlinear curves were also derived from themore » calibration readings. OSLDs with cumulative doses below 15 Gy were reused. Before an in-vivo dosimetry, the OSLD luminescence signal was erased with the white LED light. Results: For a set of 68 manufacturer-screened OSLDs, the measured sensitivities vary in a range of 17.3%. A sub-set of the OSLDs with sensitivities within ±1% was selected for the reader calibration. Three OSLDs in a group were exposed to a given radiation. Nine groups were exposed to radiation doses ranging from 0 to 13 Gy. Additional verifications demonstrated that the reader uncertainty is about 3%. With an external calibration function derived by fitting the OSLD readings to a 3rd-order polynomial, the dosimetry uncertainty dropped to 0.5%. The dose-luminescence response curves of individual OSLDs were characterized. All curves converge within 1% after the sensitivity correction. With all uncertainties considered, the systematic uncertainty is about 2%. Additional tests emulating in-vivo dosimetry by exposing the OSLDs under different radiation sources confirmed the claim. Conclusion: The sensitivity of individual OSLD should be characterized initially. A 3rd-order polynomial function is a more accurate representation of the dose-luminescence response curve. The dosimetry uncertainty specified by the

  3. Intrinsic fluorescence based in-vivo detection of cervical precancer with hand held prototype device

    NASA Astrophysics Data System (ADS)

    Meena, Bharat Lal; Raikwar, Akanksha; Pandey, Kiran; Agarwal, Asha; Pantola, Chayanika; Pradhan, Asima

    2018-02-01

    A prototype device (hand held probe) designed and fabricated in the lab has been tested for cervical precancer detection using intrinsic fluorescence. The intrinsic fluorescence gets strongly modulated by the interplay of scattering and absorption. This masks valuable biochemical information which is present in the intrinsic fluorescence. These distortion effects can be minimized by normalizing the polarized fluorescence spectra by the polarized elastic scattering spectra. The measurements have been made with a in-house fabricated device using a 405 nm diode laser and white light source respectively. 166 sites of different grades of cervical pre-cancer biopsy samples (CIN I and CIN II) (CIN: cervical intraepithelial neoplastic) have been discriminated from 29 sites of normal biopsy samples using principal component analysis (PCA) based linear discriminant analysis (LDA). The sensitivity and specificity for discrimination of normal samples from CIN I are found to be 99% and 96% respectively. Further the normal samples can be discriminated from CIN II samples with 96% sensitivity and 96% specificity. Based on these promising ex-vivo results an in-vivo study on patients has been initiated in the hospital. The hand held device built in-house shows promise as a useful tool for in vivo cervical precancer detection by polarized fluorescence. Preliminary in-vivo results on 10 patients indicate the efficacy of the hand held device for screening cervical precancers using intrinsic fluorescence.

  4. An investigation of a PRESAGE® in-vivo dosimeter for brachytherapy

    PubMed Central

    Vidovic, A K; Juang, T; Meltsner, S; Adamovics, J; Chino, J; Steffey, B; Craciunescu, O; Oldham, M

    2014-01-01

    Determining accurate in-vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in-vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm x 20 mm) tissue equivalent radiochromic dosimeter PRESAGE® In-Vivo (PRESAGE®-IV) is investigated. Two readout methods of the radiation induced change in optical density (OD) were investigated: (i) volume-averaged readout by spectrophotometer, and (ii) a line profile readout by 2D projection imaging utilizing a high-resolution (50 micron) telecentric optical system. Method (i) is considered the gold standard when applied to PRESAGE® in optical cuvettes. The feasibility of both methods was evaluated by comparison to standard measurements on PRESAGE® in optical cuvettes via spectrophotometer. An end-to-end feasibility study was performed by a side-by-side comparison with TLDs in an 192Ir HDR delivery. 7 and 8 Gy was delivered to PRESAGE®-IV and TLDs attached to the surface of a vaginal cylinder. Known geometry enabled direct comparison of measured dose with commissioned treatment planning system. A high-resolution readout study under a steep dose gradient region showed 98.9% (5%/1 mm) agreement between PRESAGE®-IV and Gafchromic® EBT2 Film. Spectrometer measurements exhibited a linear dose response between 0–15 Gy with sensitivity of 0.0133 ± 0.0007 ΔOD/(Gy·cm) at the 95% confidence interval. Method (ii) yielded a linear response with sensitivity of 0.0132 ± 0.0006 (ΔOD/Gy), within 2% of method (i). Method (i) has poor spatial resolution due to volume averaging. Method (ii) has higher resolution (~1mm) without loss of sensitivity or increased noise. Both readout methods are shown to be feasible. The end-to-end comparison revealed a 2.5% agreement between PRESAGE®-IV and treatment plan in regions of uniform high dose. PRESAGE®-IV shows promise for in-vivo dose verification, although

  5. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    PubMed Central

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  6. Screening methods for assessment of biodegradability of chemicals in seawater--results from a ring test

    SciTech Connect

    Nyholm, N.; Kristensen, P.

    1992-04-01

    An international ring test involving 14 laboratories was organized on behalf of the Commission of the European Economic Communities (EEC) with the purpose of evaluating two proposed screening methods for assessment of biodegradability in seawater: (a) a shake flask die-away test based primarily on analysis of dissolved organic carbon and (b) a closed bottle test based on determination of dissolved oxygen. Both tests are performed with nutrient-enriched natural seawater as the test medium and with no inoculum added other than the natural seawater microflora. The test methods are seawater versions of the modified OECD screening test and the closed bottlemore » test, respectively, adopted by the Organization for Economic Cooperation and Development (OECD) and by the EEC as tests for ready biodegradability.' The following five chemicals were examined: sodium benzoate, aniline, diethylene glycol, pentaerythritol, and 4-nitrophenol. Sodium benzoate and aniline, which are known to be generally readily biodegradable consistently degraded in practically all tests, thus demonstrating the technical feasibility of the methods. Like in previous ring tests with freshwater screening methods variable results were obtained with the other three compounds, which is believed primarily to be due to site-specific differences between the microflora of the different seawater samples used and to some extent also to differences in the applied concentrations of test material. A positive result with the screening methods indicates that the test substance will most likely degrade relatively rapidly in seawater from the site of collection, while a negative test result does not preclude biodegradability under environmental conditions where the concentrations of chemicals are much lower than the concentrations applied for analytical reasons in screening tests.« less

  7. A review on EEG-based methods for screening and diagnosing alcohol use disorder.

    PubMed

    Mumtaz, Wajid; Vuong, Pham Lam; Malik, Aamir Saeed; Rashid, Rusdi Bin Abd

    2018-04-01

    The screening test for alcohol use disorder (AUD) patients has been of subjective nature and could be misleading in particular cases such as a misreporting the actual quantity of alcohol intake. Although the neuroimaging modality such as electroencephalography (EEG) has shown promising research results in achieving objectivity during the screening and diagnosis of AUD patients. However, the translation of these findings for clinical applications has been largely understudied and hence less clear. This study advocates the use of EEG as a diagnostic and screening tool for AUD patients that may help the clinicians during clinical decision making. In this context, a comprehensive review on EEG-based methods is provided including related electrophysiological techniques reported in the literature. More specifically, the EEG abnormalities associated with the conditions of AUD patients are summarized. The aim is to explore the potentials of objective techniques involving quantities/features derived from resting EEG, event-related potentials or event-related oscillations data.

  8. The effectiveness of scoliosis screening programs: methods for systematic review and expert panel recommendations formulation

    PubMed Central

    2013-01-01

    Background Literature on scoliosis screening is vast, however because of the observational nature of available data and methodological flaws, data interpretation is often complex, leading to incomplete and sometimes, somewhat misleading conclusions. The need to propose a set of methods for critical appraisal of the literature about scoliosis screening, a comprehensive summary and rating of the available evidence appeared essential. Methods To address these gaps, the study aims were: i) To propose a framework for the assessment of published studies on scoliosis screening effectiveness; ii) To suggest specific questions to be answered on screening effectiveness instead of trying to reach a global position for or against the programs; iii) To contextualize the knowledge through expert panel consultation and meaningful recommendations. The general methodological approach proceeds through the following steps: Elaboration of the conceptual framework; Formulation of the review questions; Identification of the criteria for the review; Selection of the studies; Critical assessment of the studies; Results synthesis; Formulation and grading of recommendations in response to the questions. This plan follows at best GRADE Group (Grades of Recommendation, Assessment, Development and Evaluation) requirements for systematic reviews, assessing quality of evidence and grading the strength of recommendations. Conclusions In this article, the methods developed in support of this work are presented since they may be of some interest for similar reviews in scoliosis and orthopaedic fields. PMID:23883346

  9. Barrier screens: a method to sample blood-fed and host-seeking exophilic mosquitoes

    PubMed Central

    2013-01-01

    Background Determining the proportion of blood meals on humans by outdoor-feeding and resting mosquitoes is challenging. This is largely due to the difficulty of finding an adequate and unbiased sample of resting, engorged mosquitoes to enable the identification of host blood meal sources. This is particularly difficult in the south-west Pacific countries of Indonesia, the Solomon Islands and Papua New Guinea where thick vegetation constitutes the primary resting sites for the exophilic mosquitoes that are the primary malaria and filariasis vectors. Methods Barrier screens of shade-cloth netting attached to bamboo poles were constructed between villages and likely areas where mosquitoes might seek blood meals or rest. Flying mosquitoes, obstructed by the barrier screens, would temporarily stop and could then be captured by aspiration at hourly intervals throughout the night. Results In the three countries where this method was evaluated, blood-fed females of Anopheles farauti, Anopheles bancroftii, Anopheles longirostris, Anopheles sundaicus, Anopheles vagus, Anopheles kochi, Anopheles annularis, Anopheles tessellatus, Culex vishnui, Culex quinquefasciatus and Mansonia spp were collected while resting on the barrier screens. In addition, female Anopheles punctulatus and Armigeres spp as well as male An. farauti, Cx. vishnui, Cx. quinquefasciatus and Aedes species were similarly captured. Conclusions Building barrier screens as temporary resting sites in areas where mosquitoes were likely to fly was an extremely time-effective method for collecting an unbiased representative sample of engorged mosquitoes for determining the human blood index. PMID:23379959

  10. Thin-Film Thermoelectric Module for Power Generator Applications Using a Screen-Printing Method

    NASA Astrophysics Data System (ADS)

    Lee, Heon-Bok; Yang, Hyun Jeong; We, Ju Hyung; Kim, Kukjoo; Choi, Kyung Cheol; Cho, Byung Jin

    2011-05-01

    A new process for fabricating a low-cost thermoelectric module using a screen-printing method has been developed. Thermoelectric properties of screen-printed ZnSb films were investigated in an effort to develop a thermoelectric module with low cost per watt. The screen-printed Zn x Sb1- x films showed a low carrier concentration and high Seebeck coefficient when x was in the range of 0.5 to 0.57 and the annealing temperature was kept below 550°C. When the annealing temperature was higher than 550°C, the carrier concentration of the Zn x Sb1- x films reached that of a metal, leading to a decrease of the Seebeck coefficient. In the present experiment, the optimized carrier concentration of screen-printed ZnSb was 7 × 1018/cm3. The output voltage and power density of the ZnSb film were 10 mV and 0.17 mW/cm2, respectively, at Δ T = 50 K. A thermoelectric module was produced using the proposed screen-printing approach with ZnSb and CoSb3 as p-type and n-type thermoelectric materials, respectively, and copper as the pad metal.

  11. Cost and effectiveness comparison of two methods for screening potential blood donors for anaemia in Vietnam.

    PubMed

    Tyrrell, A; Worrall, E; Que, T N; Bates, I

    2011-06-01

    To compare the cost and effectiveness of Copper Sulphate (CS) and HemoCue (HC) methods for screening blood donors for anaemia. Robust information from developing countries about cost and effectiveness of anaemia screening methods for blood donors is scarce. In such countries there are widespread shortages of blood, so the most cost-effective method should maximise blood supply without compromising donor safety. Economic data (e.g. staff time, equipment and buildings) were collected from direct observation of procedures and purchase data from Hanoi's Central Blood Bank administrative department. A framework for comparing the cost and effectiveness of anaemia screening methods was developed and a cost per effective (i.e. usable and accurate) test was generated for each method. Samples from 100 potential donors from the Hanoi Central Blood Bank (static) and 198 from two mobile units were tested. The mean probability of an ineffective anaemia test was 0·1 (0·05-0·2). The average cost of an HC test was $0·75 (static $0·61 and mobile $0·89) and a CS test was $0·31 (static $0·17 and mobile $0·45). The difference between static and mobile units was predominantly due to transport costs; the difference between the two methods was predominantly due to the HC microcuvettes. In this setting the CS yields greater value for money than the HC method for screening blood donors. The relative cost and effectiveness of CS and HC may be different in places with higher staff turnover, lower test accuracy, higher anaemia prevalence or lower workload than in Vietnam. © 2010 Liverpool School of Tropical Medicine. Transfusion Medicine © 2010 British Blood Transfusion Society.

  12. New Method of Screening Young Children for Defects in Visual Acuity*

    PubMed Central

    Withnell, Allan; Wilson, H. E.

    1968-01-01

    The methods used at present for screening young children's vision have disadvantages, such as that the child's intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed. PMID:5681052

  13. New method of screening young children for defects in visual acuity.

    PubMed

    Withnell, A; Wilson, H E

    1968-10-19

    The methods used at present for screening young children's vision have disadvantages, such as that the child's intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed.

  14. Rapid screening of guar gum using portable Raman spectral identification methods.

    PubMed

    Srivastava, Hirsch K; Wolfgang, Steven; Rodriguez, Jason D

    2016-01-25

    Guar gum is a well-known inactive ingredient (excipient) used in a variety of oral pharmaceutical dosage forms as a thickener and stabilizer of suspensions and as a binder of powders. It is also widely used as a food ingredient in which case alternatives with similar properties, including chemically similar gums, are readily available. Recent supply shortages and price fluctuations have caused guar gum to come under increasing scrutiny for possible adulteration by substitution of cheaper alternatives. One way that the U.S. FDA is attempting to screen pharmaceutical ingredients at risk for adulteration or substitution is through field-deployable spectroscopic screening. Here we report a comprehensive approach to evaluate two field-deployable Raman methods--spectral correlation and principal component analysis--to differentiate guar gum from other gums. We report a comparison of the sensitivity of the spectroscopic screening methods with current compendial identification tests. The ability of the spectroscopic methods to perform unambiguous identification of guar gum compared to other gums makes them an enhanced surveillance alternative to the current compendial identification tests, which are largely subjective in nature. Our findings indicate that Raman spectral identification methods perform better than compendial identification methods and are able to distinguish guar gum from other gums with 100% accuracy for samples tested by spectral correlation and principal component analysis. Published by Elsevier B.V.

  15. Design of multifunctional nanoparticles for combined in-vivo imaging and advanced drug delivery

    NASA Astrophysics Data System (ADS)

    Leary, James F.

    2018-02-01

    Design of multifunctional nanoparticles for multimodal in-vivo imaging and advanced targeting to diseased single cells for massive parallel processing nanomedicine approaches requires careful overall design and a multilayered approach. Initial core materials can include non-toxic metals which not only serve as an x-ray contrast agent for CAT scan imaging, but can contain T1 or T2 contrast agents for MRI imaging. One choice is superparamagnetic iron oxide NPs which also allow for convenient magnetic manipulation during manufacturing but also for re-positioning inside the body and for single cell hyperthermia therapies. To permit real-time fluorescence-guided surgery, fluorescence molecules can be included. Advanced targeting can be achieved by attaching antibodies, peptides, aptamers, or other targeting molecules to the nanoparticle in a multilayered approach producing "programmable nanoparticles" whereby the "programming" means controlling a sequence of multi-step targeting methods. Addition of membrane permeating peptides can facilitate uptake by the cell. Addition of "stealth" molecules (e.g. PEG or chitosan) to the outer surfaces of the nanoparticles can permit greatly enhanced circulation times in-vivo which in turn lead to lower amounts of drug exposure to the patient which can reduce undesirable side effects. Nanoparticles with incomplete layers can be removed by affinity purification methods to minimize mistargeting events in-vivo. Nanoscale imaging of these manufactured, multifunctional nanoparticles can be achieved either directly through superresolution microscopy or indirectly through single nanoparticle zeta-sizing or x-ray correlation microscopy. Since these multifunctional nanoparticles are best analyzed by technologies permitting analysis in aqueous environments, superresolution microscopy is, in most cases, the preferred method.

  16. School Locations and Traffic Emissions — Environmental (In)Justice Findings Using a New Screening Method

    PubMed Central

    Gaffron, Philine; Niemeier, Deb

    2015-01-01

    It has been shown that the location of schools near heavily trafficked roads can have detrimental effects on the health of children attending those schools. It is therefore desirable to screen both existing school locations and potential new school sites to assess either the need for remedial measures or suitability for the intended use. Current screening tools and public guidance on school siting are either too coarse in their spatial resolution for assessing individual sites or are highly resource intensive in their execution (e.g., through dispersion modeling). We propose a new method to help bridge the gap between these two approaches. Using this method, we also examine the public K-12 schools in the Sacramento Area Council of Governments Region, California (USA) from an environmental justice perspective. We find that PM2.5 emissions from road traffic affecting a school site are significantly positively correlated with the following metrics: percent share of Black, Hispanic and multi-ethnic students, percent share of students eligible for subsidized meals. The emissions metric correlates negatively with the schools’ Academic Performance Index, the share of White students and average parental education levels. Our PM2.5 metric also correlates with the traffic related, census tract level screening indicators from the California Communities Environmental Health Screening Tool and the tool’s tract level rate of asthma related emergency department visits. PMID:25679341

  17. School-based BMI and body composition screening and parent notification in California: methods and messages.

    PubMed

    Madsen, Kristine A; Linchey, Jennifer

    2012-06-01

    School-based body mass index (BMI) or body composition screening is increasing, but little is known about the process of parent notification. Since 2001, California has required annual screening of body composition via the FITNESSGRAM, with optional notification. This study sought to identify the prevalence of parental notification when screening is required but notification is optional, and the methods and messages used. Researchers conducted phone interviews with 851 school districts (89%) in California and reviewed notification materials from 54 districts. As of 2008, 53% of California districts notified parents of screening results. Many districts (24%) did not know the reason for their notification policy. Most districts notified parents via a letter mailed home (70%) or sent home with the child (18%). Whereas 79% of sample letters provided students' BMI, only 12% provided an explanation of BMI, and only half provided tips on what parents should do if concerned about their child's results. In California, where body composition screening is required but parent notification is not, approximately half of school districts elect to notify parents of results, most commonly via letter. Most letters do not explain BMI or percent body fat scores, nor do they suggest what parents should do for a child identified as at-risk. Further research to identify interpretable and actionable notification messages for parents will be critical if school-based BMI and body composition screening and notification is to reduce childhood obesity. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.

  18. A Novel Approach for Efficient Pharmacophore-based Virtual Screening: Method and Applications

    PubMed Central

    Dror, Oranit; Schneidman-Duhovny, Dina; Inbar, Yuval; Nussinov, Ruth; Wolfson, Haim J.

    2009-01-01

    Virtual screening is emerging as a productive and cost-effective technology in rational drug design for the identification of novel lead compounds. An important model for virtual screening is the pharmacophore. Pharmacophore is the spatial configuration of essential features that enable a ligand molecule to interact with a specific target receptor. In the absence of a known receptor structure, a pharmacophore can be identified from a set of ligands that have been observed to interact with the target receptor. Here, we present a novel computational method for pharmacophore detection and virtual screening. The pharmacophore detection module is able to: (i) align multiple flexible ligands in a deterministic manner without exhaustive enumeration of the conformational space, (ii) detect subsets of input ligands that may bind to different binding sites or have different binding modes, (iii) address cases where the input ligands have different affinities by defining weighted pharmacophores based on the number of ligands that share them, and (iv) automatically select the most appropriate pharmacophore candidates for virtual screening. The algorithm is highly efficient, allowing a fast exploration of the chemical space by virtual screening of huge compound databases. The performance of PharmaGist was successfully evaluated on a commonly used dataset of G-Protein Coupled Receptor alpha1A. Additionally, a large-scale evaluation using the DUD (directory of useful decoys) dataset was performed. DUD contains 2950 active ligands for 40 different receptors, with 36 decoy compounds for each active ligand. PharmaGist enrichment rates are comparable with other state-of-the-art tools for virtual screening. Availability The software is available for download. A user-friendly web interface for pharmacophore detection is available at http://bioinfo3d.cs.tau.ac.il/PharmaGist. PMID:19803502

  19. In-vivo dark-field and phase-contrast x-ray imaging

    NASA Astrophysics Data System (ADS)

    Bech, M.; Tapfer, A.; Velroyen, A.; Yaroshenko, A.; Pauwels, B.; Hostens, J.; Bruyndonckx, P.; Sasov, A.; Pfeiffer, F.

    2013-11-01

    Novel radiography approaches based on the wave nature of x-rays when propagating through matter have a great potential for improved future x-ray diagnostics in the clinics. Here, we present a significant milestone in this imaging method: in-vivo multi-contrast x-ray imaging of a mouse using a compact scanner. Of particular interest is the enhanced contrast in regions related to the respiratory system, indicating a possible application in diagnosis of lung diseases (e.g. emphysema).

  20. Nanoliter microfluidic hybrid method for simultaneous screening and optimization validated with crystallization of membrane proteins

    PubMed Central

    Li, Liang; Mustafi, Debarshi; Fu, Qiang; Tereshko, Valentina; Chen, Delai L.; Tice, Joshua D.; Ismagilov, Rustem F.

    2006-01-01

    High-throughput screening and optimization experiments are critical to a number of fields, including chemistry and structural and molecular biology. The separation of these two steps may introduce false negatives and a time delay between initial screening and subsequent optimization. Although a hybrid method combining both steps may address these problems, miniaturization is required to minimize sample consumption. This article reports a “hybrid” droplet-based microfluidic approach that combines the steps of screening and optimization into one simple experiment and uses nanoliter-sized plugs to minimize sample consumption. Many distinct reagents were sequentially introduced as ≈140-nl plugs into a microfluidic device and combined with a substrate and a diluting buffer. Tests were conducted in ≈10-nl plugs containing different concentrations of a reagent. Methods were developed to form plugs of controlled concentrations, index concentrations, and incubate thousands of plugs inexpensively and without evaporation. To validate the hybrid method and demonstrate its applicability to challenging problems, crystallization of model membrane proteins and handling of solutions of detergents and viscous precipitants were demonstrated. By using 10 μl of protein solution, ≈1,300 crystallization trials were set up within 20 min by one researcher. This method was compatible with growth, manipulation, and extraction of high-quality crystals of membrane proteins, demonstrated by obtaining high-resolution diffraction images and solving a crystal structure. This robust method requires inexpensive equipment and supplies, should be especially suitable for use in individual laboratories, and could find applications in a number of areas that require chemical, biochemical, and biological screening and optimization. PMID:17159147

  1. Real-time and online screening method for materials emitting volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Kim, Changhyuk; Sul, Yong Tae; Pui, David Y. H.

    2016-09-01

    In the semiconductor industry, volatile organic compounds (VOCs) in the cleanroom air work as airborne molecular contamination, which reduce the production yield of semiconductor chips by forming nanoparticles and haze on silicon wafers and photomasks under ultraviolet irradiation during photolithography processes. Even though VOCs in outdoor air are removed by gas filters, VOCs can be emitted from many kinds of materials used in cleanrooms, such as organic solvents and construction materials (e.g., adhesives, flame retardants and sealants), threatening the production of semiconductors. Therefore, finding new replacements that emit lower VOCs is now essential in the semiconductor industry. In this study, we developed a real-time and online method to screen materials for developing the replacements by converting VOCs into nanoparticles under soft X-ray irradiation. This screening method was applied to measure VOCs emitted from different kinds of organic solvents and adhesives. Our results showed good repeatability and high sensitivity for VOCs, which come from aromatic compounds, some alcohols and all tested adhesives (Super glue and cleanroom-use adhesives). In addition, the overall trend of measured VOCs from cleanroom-use adhesives was well matched with those measured by a commercial thermal desorption-gas chromatography-mass spectrometry, which is a widely used off-line method for analyzing VOCs. Based on the results, this screening method can help accelerate the developing process for reducing VOCs in cleanrooms.

  2. Electrochemical estrogen screen method based on the electrochemical behavior of MCF-7 cells.

    PubMed

    Li, Jinlian; Song, Jia; Bi, Sheng; Zhou, Shi; Cui, Jiwen; Liu, Jiguang; Wu, Dongmei

    2016-08-05

    It was an urgent task to develop quick, cheap and accurate estrogen screen method for evaluating the estrogen effect of the booming chemicals. In this study, the voltammetric behavior between the estrogen-free and normal fragmented MCF-7 cell suspensions were compared, and the electrochemical signal (about 0.68V attributed by xanthine and guanine) of the estrogen-free fragmented MCF-7 cell suspension was obviously lower than that of the normal one. The electrochemistry detection of ex-secretion purines showed that the ability of ex-secretion purines of cells sharp decreased due to the removing of endogenous estrogen. The results indicated that the electrochemical signal of MCF-7 cells was related to the level of intracellular estrogen. When the level of intracellular estrogen was down-regulated, the concentrations of the xanthine and hypoxanthine decreased, which led to the electrochemical signal of MCF-7 cells fall. Based on the electrochemical signal, the electrochemical estrogen screen method was established. The estrogen effect of estradiol, nonylphenol and bisphenol A was evaluated with the electrochemical method, and the result was accordant with that of MTT assay. The electrochemical estrogen screen method was simple, quickly, cheap, objective, and it exploits a new way for the evaluation of estrogenic effects of chemicals. Copyright © 2016. Published by Elsevier B.V.

  3. Optimal Methods to Screen Men and Women for Intimate Partner Violence: Results from an Internal Medicine Residency Continuity Clinic

    ERIC Educational Resources Information Center

    Kapur, Nitin A.; Windish, Donna M.

    2011-01-01

    Contradictory data exist regarding optimal methods and instruments for intimate partner violence (IPV) screening in primary care settings. The purpose of this study was to determine the optimal method and screening instrument for IPV among men and women in a primary-care resident clinic. We conducted a cross-sectional study at an urban, academic,…

  4. A Novel Two-Step Method for Screening Shade Tolerant Mutant Plants via Dwarfism

    PubMed Central

    Li, Wei; Katin-Grazzini, Lorenzo; Krishnan, Sanalkumar; Thammina, Chandra; El-Tanbouly, Rania; Yer, Huseyin; Merewitz, Emily; Guillard, Karl; Inguagiato, John; McAvoy, Richard J.; Liu, Zongrang; Li, Yi

    2016-01-01

    When subjected to shade, plants undergo rapid shoot elongation, which often makes them more prone to disease and mechanical damage. Shade-tolerant plants can be difficult to breed; however, they offer a substantial benefit over other varieties in low-light areas. Although perennial ryegrass (Lolium perenne L.) is a popular species of turf grasses because of their good appearance and fast establishment, the plant normally does not perform well under shade conditions. It has been reported that, in turfgrass, induced dwarfism can enhance shade tolerance. Here we describe a two-step procedure for isolating shade tolerant mutants of perennial ryegrass by first screening for dominant dwarf mutants, and then screening dwarf plants for shade tolerance. The two-step screening process to isolate shade tolerant mutants can be done efficiently with limited space at early seedling stages, which enables quick and efficient isolation of shade tolerant mutants, and thus facilitates development of shade tolerant new cultivars of turfgrasses. Using the method, we isolated 136 dwarf mutants from 300,000 mutagenized seeds, with 65 being shade tolerant (0.022%). When screened directly for shade tolerance, we recovered only four mutants from a population of 150,000 (0.003%) mutagenized seeds. One shade tolerant mutant, shadow-1, was characterized in detail. In addition to dwarfism, shadow-1 and its sexual progeny displayed high degrees of tolerance to both natural and artificial shade. We showed that endogenous gibberellin (GA) content in shadow-1 was higher than wild-type controls, and shadow-1 was also partially GA insensitive. Our novel, simple and effective two-step screening method should be applicable to breeding shade tolerant cultivars of turfgrasses, ground covers, and other economically important crop plants that can be used under canopies of existing vegetation to increase productivity per unit area of land. PMID:27752260

  5. Using stable isotopes to monitor forms of sulfur during desulfurization processes: A quick screening method

    USGS Publications Warehouse

    Liu, Chao-Li; Hackley, Keith C.; Coleman, D.D.; Kruse, C.W.

    1987-01-01

    A method using stable isotope ratio analysis to monitor the reactivity of sulfur forms in coal during thermal and chemical desulfurization processes has been developed at the Illinois State Geological Survey. The method is based upon the fact that a significant difference exists in some coals between the 34S/32S ratios of the pyritic and organic sulfur. A screening method for determining the suitability of coal samples for use in isotope ratio analysis is described. Making these special coals available from coal sample programs would assist research groups in sorting out the complex sulfur chemistry which accompanies thermal and chemical processing of high sulfur coals. ?? 1987.

  6. Ultra-high-throughput screening method for the directed evolution of glucose oxidase.

    PubMed

    Ostafe, Raluca; Prodanovic, Radivoje; Nazor, Jovana; Fischer, Rainer

    2014-03-20

    Glucose oxidase (GOx) is used in many industrial processes that could benefit from improved versions of the enzyme. Some improvements like higher activity under physiological conditions and thermal stability could be useful for GOx applications in biosensors and biofuel cells. Directed evolution is one of the currently available methods to engineer improved GOx variants. Here, we describe an ultra-high-throughput screening system for sorting the best enzyme variants generated by directed evolution that incorporates several methodological refinements: flow cytometry, in vitro compartmentalization, yeast surface display, fluorescent labeling of the expressed enzyme, delivery of glucose substrate to the reaction mixture through the oil phase, and covalent labeling of the cells with fluorescein-tyramide. The method enables quantitative screening of gene libraries to identify clones with improved activity and it also allows cells to be selected based not only on the overall activity but also on the specific activity of the enzyme. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. A method of measuring and correcting tilt of anti - vibration wind turbines based on screening algorithm

    NASA Astrophysics Data System (ADS)

    Xiao, Zhongxiu

    2018-04-01

    A Method of Measuring and Correcting Tilt of Anti - vibration Wind Turbines Based on Screening Algorithm is proposed in this paper. First of all, we design a device which the core is the acceleration sensor ADXL203, the inclination is measured by installing it on the tower of the wind turbine as well as the engine room. Next using the Kalman filter algorithm to filter effectively by establishing a state space model for signal and noise. Then we use matlab for simulation. Considering the impact of the tower and nacelle vibration on the collected data, the original data and the filtering data are classified and stored by the Screening algorithm, then filter the filtering data to make the output data more accurate. Finally, we eliminate installation errors by using algorithm to achieve the tilt correction. The device based on this method has high precision, low cost and anti-vibration advantages. It has a wide range of application and promotion value.

  8. Application of a screening method in assessing occupational safety and health of computer workstations.

    PubMed

    Niskanen, Toivo; Lehtelä, Jouni; Länsikallio, Riina

    2014-01-01

    Employers and workers need concrete guidance to plan and implement changes in the ergonomics of computer workstations. The Näppärä method is a screening tool for identifying problems requiring further assessment and corrective actions. The aim of this study was to assess the work of occupational safety and health (OSH) government inspectors who used Näppärä as part of their OSH enforcement inspections (430 assessments) related to computer work. The modifications in workstation ergonomics involved mainly adjustments to the screen, mouse, keyboard, forearm supports, and chair. One output of the assessment is an index indicating the percentage of compliance items. This method can be considered as exposure assessment and ergonomics intervention used as a benchmark for the level of ergonomics. Future research can examine whether the effectiveness of participatory ergonomics interventions should be investigated with Näppärä.

  9. Methods for efficient high-throughput screening of protein expression in recombinant Pichia pastoris strains.

    PubMed

    Camattari, Andrea; Weinhandl, Katrin; Gudiminchi, Rama K

    2014-01-01

    The methylotrophic yeast Pichia pastoris is becoming one of the favorite industrial workhorses for protein expression. Due to the widespread use of integration vectors, which generates significant clonal variability, screening methods allowing assaying hundreds of individual clones are of particular importance. Here we describe methods to detect and analyze protein expression, developed in a 96-well format for high-throughput screening of recombinant P. pastoris strains. The chapter covers essentially three common scenarios: (1) an enzymatic assay for proteins expressed in the cell cytoplasm, requiring cell lysis; (2) a whole-cell assay for a fungal cytochrome P450; and (3) a nonenzymatic assay for detection and quantification of tagged protein secreted into the supernatant.

  10. Cocrystal screening of hydroxybenzamides with benzoic acid derivatives: a comparative study of thermal and solution-based methods.

    PubMed

    Manin, Alex N; Voronin, Alexander P; Drozd, Ksenia V; Manin, Nikolay G; Bauer-Brandl, Annette; Perlovich, German L

    2014-12-18

    The main problem occurring at the early stages of cocrystal search is the choice of an effective screening technique. Among the most popular techniques of obtaining cocrystals are crystallization from solution, crystallization from melt and solvent-drop grinding. This paper represents a comparative analysis of the following screening techniques: DSC cocrystal screening method, thermal microscopy and saturation temperature method. The efficiency of different techniques of cocrystal screening was checked in 18 systems. Benzamide and benzoic acid derivatives were chosen as model systems due to their ability to form acid-amide supramolecular heterosynthon. The screening has confirmed the formation of 6 new cocrystals. The screening by the saturation temperature method has the highest screen-out rate but the smallest range of application. DSC screening has a satisfactory accuracy and allows screening over a short time. Thermal microscopy is most efficient as an additional technique used to interpret ambiguous DSC screening results. The study also included an analysis of the influence of solvent type and component solubility on cocrystal formation. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Method for screening prevention and control measures and technologies based on groundwater pollution intensity assessment.

    PubMed

    Li, Juan; Yang, Yang; Huan, Huan; Li, Mingxiao; Xi, Beidou; Lv, Ningqing; Wu, Yi; Xie, Yiwen; Li, Xiang; Yang, Jinjin

    2016-05-01

    This paper presents a system for determining the evaluation and gradation indices of groundwater pollution intensity (GPI). Considering the characteristics of the vadose zone and pollution sources, the system decides which anti-seepage measures should be implemented at the contaminated site. The pollution sources hazards (PSH) and groundwater intrinsic vulnerability (GIV) are graded by the revised Nemerow Pollution Index and an improved DRTAS model, respectively. GPI is evaluated and graded by a double-sided multi-factor coupling model, which is constructed by the matrix method. The contaminated sites are categorized as prior, ordinary, or common sites. From the GPI results, we develop guiding principles for preventing and removing pollution sources, procedural interruption and remediation, and end treatment and monitoring. Thus, we can select appropriate prevention and control technologies (PCT). To screen the technological schemes and optimize the traditional analytical hierarchy process (AHP), we adopt the technique for order preference by the similarity to ideal solution (TOPSIS) method. Our GPI approach and PCT screening are applied to three types of pollution sites: the refuse dump of a rare earth mine development project (a potential pollution source), a chromium slag dump, and a landfill (existing pollution sources). These three sites are identified as ordinary, prior, and ordinary sites, respectively. The anti-seepage materials at the refuse dump should perform as effectively as a 1.5-m-thick clay bed. The chromium slag dump should be preferentially treated by soil flushing and in situ chemical remediation. The landfill should be treated by natural attenuation technology. The proposed PCT screening approach was compared with conventional screening methods results at the three sites and proved feasible and effective. The proposed method can provide technical support for the monitoring and management of groundwater pollution in China. Copyright © 2015

  12. Methods for Effective Virtual Screening and Scaffold-Hopping in Chemical Compounds

    DTIC Science & Technology

    2007-04-04

    contains color images. 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 12 19a...Opterons with 4 GB of memory . We used the descriptor- spaces GF, ECZ3, and ErG (described in Section 4) for the evaluating the methods introduced in...screening: Use of data fusion and machine learning to enchance the effectiveness of sim- ilarity searching. J. Chem. Info. Model., (46):462–470, 2006. [18] J

  13. On the Use of Accelerated Aging Methods for Screening High Temperature Polymeric Composite Materials

    NASA Technical Reports Server (NTRS)

    Gates, Thomas S.; Grayson, Michael A.

    1999-01-01

    A rational approach to the problem of accelerated testing of high temperature polymeric composites is discussed. The methods provided are considered tools useful in the screening of new materials systems for long-term application to extreme environments that include elevated temperature, moisture, oxygen, and mechanical load. The need for reproducible mechanisms, indicator properties, and real-time data are outlined as well as the methodologies for specific aging mechanisms.

  14. Statistical studies of animal response data from USF toxicity screening test method

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Machado, A. M.

    1978-01-01

    Statistical examination of animal response data obtained using Procedure B of the USF toxicity screening test method indicates that the data deviate only slightly from a normal or Gaussian distribution. This slight departure from normality is not expected to invalidate conclusions based on theoretical statistics. Comparison of times to staggering, convulsions, collapse, and death as endpoints shows that time to death appears to be the most reliable endpoint because it offers the lowest probability of missed observations and premature judgements.

  15. Microengineering methods for cell-based microarrays and high-throughput drug-screening applications.

    PubMed

    Xu, Feng; Wu, JinHui; Wang, ShuQi; Durmus, Naside Gozde; Gurkan, Umut Atakan; Demirci, Utkan

    2011-09-01

    Screening for effective therapeutic agents from millions of drug candidates is costly, time consuming, and often faces concerns due to the extensive use of animals. To improve cost effectiveness, and to minimize animal testing in pharmaceutical research, in vitro monolayer cell microarrays with multiwell plate assays have been developed. Integration of cell microarrays with microfluidic systems has facilitated automated and controlled component loading, significantly reducing the consumption of the candidate compounds and the target cells. Even though these methods significantly increased the throughput compared to conventional in vitro testing systems and in vivo animal models, the cost associated with these platforms remains prohibitively high. Besides, there is a need for three-dimensional (3D) cell-based drug-screening models which can mimic the in vivo microenvironment and the functionality of the native tissues. Here, we present the state-of-the-art microengineering approaches that can be used to develop 3D cell-based drug-screening assays. We highlight the 3D in vitro cell culture systems with live cell-based arrays, microfluidic cell culture systems, and their application to high-throughput drug screening. We conclude that among the emerging microengineering approaches, bioprinting holds great potential to provide repeatable 3D cell-based constructs with high temporal, spatial control and versatility.

  16. Microengineering Methods for Cell Based Microarrays and High-Throughput Drug Screening Applications

    PubMed Central

    Xu, Feng; Wu, JinHui; Wang, ShuQi; Durmus, Naside Gozde; Gurkan, Umut Atakan; Demirci, Utkan

    2011-01-01

    Screening for effective therapeutic agents from millions of drug candidates is costly, time-consuming and often face ethical concerns due to extensive use of animals. To improve cost-effectiveness, and to minimize animal testing in pharmaceutical research, in vitro monolayer cell microarrays with multiwell plate assays have been developed. Integration of cell microarrays with microfluidic systems have facilitated automated and controlled component loading, significantly reducing the consumption of the candidate compounds and the target cells. Even though these methods significantly increased the throughput compared to conventional in vitro testing systems and in vivo animal models, the cost associated with these platforms remains prohibitively high. Besides, there is a need for three-dimensional (3D) cell based drug-screening models, which can mimic the in vivo microenvironment and the functionality of the native tissues. Here, we present the state-of-the-art microengineering approaches that can be used to develop 3D cell based drug screening assays. We highlight the 3D in vitro cell culture systems with live cell-based arrays, microfluidic cell culture systems, and their application to high-throughput drug screening. We conclude that among the emerging microengineering approaches, bioprinting holds a great potential to provide repeatable 3D cell based constructs with high temporal, spatial control and versatility. PMID:21725152

  17. Parallel production and verification of protein products using a novel high-throughput screening method.

    PubMed

    Tegel, Hanna; Yderland, Louise; Boström, Tove; Eriksson, Cecilia; Ukkonen, Kaisa; Vasala, Antti; Neubauer, Peter; Ottosson, Jenny; Hober, Sophia

    2011-08-01

    Protein production and analysis in a parallel fashion is today applied in laboratories worldwide and there is a great need to improve the techniques and systems used for this purpose. In order to save time and money, a fast and reliable screening method for analysis of protein production and also verification of the protein product is desired. Here, a micro-scale protocol for the parallel production and screening of 96 proteins in plate format is described. Protein capture was achieved using immobilized metal affinity chromatography and the product was verified using matrix-assisted laser desorption ionization time-of-flight MS. In order to obtain sufficiently high cell densities and product yield in the small-volume cultivations, the EnBase® cultivation technology was applied, which enables cultivation in as small volumes as 150 μL. Here, the efficiency of the method is demonstrated by producing 96 human, recombinant proteins, both in micro-scale and using a standard full-scale protocol and comparing the results in regard to both protein identity and sample purity. The results obtained are highly comparable to those acquired through employing standard full-scale purification protocols, thus validating this method as a successful initial screening step before protein production at a larger scale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Condorcet and borda count fusion method for ligand-based virtual screening.

    PubMed

    Ahmed, Ali; Saeed, Faisal; Salim, Naomie; Abdo, Ammar

    2014-01-01

    It is known that any individual similarity measure will not always give the best recall of active molecule structure for all types of activity classes. Recently, the effectiveness of ligand-based virtual screening approaches can be enhanced by using data fusion. Data fusion can be implemented using two different approaches: group fusion and similarity fusion. Similarity fusion involves searching using multiple similarity measures. The similarity scores, or ranking, for each similarity measure are combined to obtain the final ranking of the compounds in the database. The Condorcet fusion method was examined. This approach combines the outputs of similarity searches from eleven association and distance similarity coefficients, and then the winner measure for each class of molecules, based on Condorcet fusion, was chosen to be the best method of searching. The recall of retrieved active molecules at top 5% and significant test are used to evaluate our proposed method. The MDL drug data report (MDDR), maximum unbiased validation (MUV) and Directory of Useful Decoys (DUD) data sets were used for experiments and were represented by 2D fingerprints. Simulated virtual screening experiments with the standard two data sets show that the use of Condorcet fusion provides a very simple way of improving the ligand-based virtual screening, especially when the active molecules being sought have a lowest degree of structural heterogeneity. However, the effectiveness of the Condorcet fusion was increased slightly when structural sets of high diversity activities were being sought.

  20. Condorcet and borda count fusion method for ligand-based virtual screening

    PubMed Central

    2014-01-01

    Background It is known that any individual similarity measure will not always give the best recall of active molecule structure for all types of activity classes. Recently, the effectiveness of ligand-based virtual screening approaches can be enhanced by using data fusion. Data fusion can be implemented using two different approaches: group fusion and similarity fusion. Similarity fusion involves searching using multiple similarity measures. The similarity scores, or ranking, for each similarity measure are combined to obtain the final ranking of the compounds in the database. Results The Condorcet fusion method was examined. This approach combines the outputs of similarity searches from eleven association and distance similarity coefficients, and then the winner measure for each class of molecules, based on Condorcet fusion, was chosen to be the best method of searching. The recall of retrieved active molecules at top 5% and significant test are used to evaluate our proposed method. The MDL drug data report (MDDR), maximum unbiased validation (MUV) and Directory of Useful Decoys (DUD) data sets were used for experiments and were represented by 2D fingerprints. Conclusions Simulated virtual screening experiments with the standard two data sets show that the use of Condorcet fusion provides a very simple way of improving the ligand-based virtual screening, especially when the active molecules being sought have a lowest degree of structural heterogeneity. However, the effectiveness of the Condorcet fusion was increased slightly when structural sets of high diversity activities were being sought. PMID:24883114

  1. Evaluation of detection methods for screening meat and poultry products for the presence of foodborne pathogens.

    PubMed

    Bohaychuk, Valerie M; Gensler, Gary E; King, Robin K; Wu, John T; McMullen, Lynn M

    2005-12-01

    Rapid and molecular technologies such as enzyme-linked immunosorbent assay (ELISA), PCR, and lateral flow immunoprecipitation can reduce the time and labor involved in screening food products for the presence of pathogens. These technologies were compared with conventional culture methodology for the detection of Salmonella, Campylobacter, Listeria, and Escherichia coli O157:H7 inoculated in raw and processed meat and poultry products. Recommended protocols were modified so that the same enrichment broths used in the culture methods were also used in the ELISA, PCR, and lateral flow immunoprecipitation assays. The percent agreement between the rapid technologies and culture methods ranged from 80 to 100% depending on the pathogen detected and the method used. ELISA, PCR, and lateral flow immunoprecipitation all performed well, with no statistical difference, compared with the culture method for the detection of E. coli O157:H7. ELISA performed better for the detection of Salmonella, with sensitivity and specificity rates of 100%. PCR performed better for the detection of Campylobacter jejuni, with 100% agreement to the culture method. PCR was highly sensitive for the detection of all the foodborne pathogens tested except Listeria monocytogenes. Although the lateral flow immunoprecipitation tests were statistically different from the culture methods for Salmonella and Listeria because of false-positive results, the tests did not produce any false negatives, indicating that this method would be suitable for screening meat and poultry products for these pathogens.

  2. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    PubMed

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  3. Co-registration of In-Vivo Human MRI Brain Images to Postmortem Histological Microscopic Images

    PubMed Central

    Singh, M.; Rajagopalan, A.; Kim, T.-S.; Hwang, D.; Chui, H.; Zhang, X.-L.; Lee, A.-Y.; Zarow, C.

    2009-01-01

    Certain features such as small vascular lesions seen in human MRI are detected reliably only in postmortem histological samples by microscopic imaging. Co-registration of these microscopically detected features to their corresponding locations in the in-vivo images would be of great benefit to understanding the MRI signatures of specific diseases. Using non-linear Polynomial transformation, we report a method to co-register in-vivo MRIs to microscopic images of histological samples drawn off the postmortem brain. The approach utilizes digital photographs of postmortem slices as an intermediate reference to co-register the MRIs to microscopy. The overall procedure is challenging due to gross structural deformations in the postmortem brain during extraction and subsequent distortions in the histological preparations. Hemispheres of the brain were co-registered separately to mitigate these effects. Approaches relying on matching single-slices, multiple-slices and entire volumes in conjunction with different similarity measures suggested that using four slices at a time in combination with two sequential measures, Pearson correlation coefficient followed by mutual information, produced the best MRI-postmortem co-registration according to a voxel mismatch count. The accuracy of the overall registration was evaluated by measuring the 3D Euclidean distance between the locations of microscopically identified lesions on postmortem slices and their MRI-postmortem co-registered locations. The results show a mean 3D displacement of 5.1 ± 2.0 mm between the in-vivo MRI and microscopically determined locations for 21 vascular lesions in 11 subjects. PMID:19169415

  4. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    PubMed

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  5. Management of low-grade cervical abnormalities detected at screening: which method do women prefer?

    PubMed

    Whynes, D K; Woolley, C; Philips, Z

    2008-12-01

    To establish whether women with low-grade abnormalities detected during screening for cervical cancer prefer to be managed by cytological surveillance or by immediate colposcopy. TOMBOLA (Trial of Management of Borderline and Other Low-grade Abnormal smears) is a randomized controlled trial comparing alternative management strategies following the screen-detection of low-grade cytological abnormalities. At exit, a sample of TOMBOLA women completed a questionnaire eliciting opinions on their management, contingent valuations (CV) of the management methods and preferences. Within-trial quality of life (EQ-5D) data collected for a sample of TOMBOLA women throughout their follow-up enabled the comparison of self-reported health at various time points, by management method. Once management had been initiated, self-reported health in the colposcopy arm rose relative to that in the surveillance arm, although the effect was short-term only. For the majority of women, the satisfaction ratings and the CV indicated approval of the management method to which they had been randomized. Of the minority manifesting a preference for the method which they had not experienced, relatively more would have preferred colposcopy than would have preferred surveillance. The findings must be interpreted in the light of sample bias with respect to preferences, whereby enthusiasm for colposcopy was probably over-represented amongst trial participants. The study suggests that neither of the management methods is preferred unequivocally; rather, individual women have individual preferences, although many would be indifferent between methods.

  6. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan.

    PubMed

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-06-01

    A screening method for measuring (90)Sr in edible plant samples by focusing on (90)Y in equilibrium with (90)Sr is reported. (90)Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the (90)Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. (90)Sr ((90)Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Benchmarking Data Sets for the Evaluation of Virtual Ligand Screening Methods: Review and Perspectives.

    PubMed

    Lagarde, Nathalie; Zagury, Jean-François; Montes, Matthieu

    2015-07-27

    Virtual screening methods are commonly used nowadays in drug discovery processes. However, to ensure their reliability, they have to be carefully evaluated. The evaluation of these methods is often realized in a retrospective way, notably by studying the enrichment of benchmarking data sets. To this purpose, numerous benchmarking data sets were developed over the years, and the resulting improvements led to the availability of high quality benchmarking data sets. However, some points still have to be considered in the selection of the active compounds, decoys, and protein structures to obtain optimal benchmarking data sets.

  8. A method to screen and evaluate tissue adhesives for joint repair applications

    PubMed Central

    2012-01-01

    Background Tissue adhesives are useful means for various medical procedures. Since varying requirements cause that a single adhesive cannot meet all needs, bond strength testing remains one of the key applications used to screen for new products and study the influence of experimental variables. This study was conducted to develop an easy to use method to screen and evaluate tissue adhesives for tissue engineering applications. Method Tissue grips were designed to facilitate the reproducible production of substrate tissue and adhesive strength measurements in universal testing machines. Porcine femoral condyles were used to generate osteochondral test tissue cylinders (substrates) of different shapes. Viability of substrates was tested using PI/FDA staining. Self-bonding properties were determined to examine reusability of substrates (n = 3). Serial measurements (n = 5) in different operation modes (OM) were performed to analyze the bonding strength of tissue adhesives in bone (OM-1) and cartilage tissue either in isolation (OM-2) or under specific requirements in joint repair such as filling cartilage defects with clinical applied fibrin/PLGA-cell-transplants (OM-3) or tissues (OM-4). The efficiency of the method was determined on the basis of adhesive properties of fibrin glue for different assembly times (30 s, 60 s). Seven randomly generated collagen formulations were analyzed to examine the potential of method to identify new tissue adhesives. Results Viability analysis of test tissue cylinders revealed vital cells (>80%) in cartilage components even 48 h post preparation. Reuse (n = 10) of test substrate did not significantly change adhesive characteristics. Adhesive strength of fibrin varied in different test settings (OM-1: 7.1 kPa, OM-2: 2.6 kPa, OM-3: 32.7 kPa, OM-4: 30.1 kPa) and was increasing with assembly time on average (2.4-fold). The screening of the different collagen formulations revealed a substance with significant higher adhesive

  9. Pathophysiology, risk factors, and screening methods for prediabetes in women with polycystic ovary syndrome.

    PubMed

    Gourgari, Evgenia; Spanakis, Elias; Dobs, Adrian Sandra

    2016-01-01

    Polycystic ovary syndrome (PCOS) is a syndrome associated with insulin resistance (IR), obesity, infertility, and increased cardiometabolic risk. This is a descriptive review of several mechanisms that can explain the IR among women with PCOS, other risk factors for the development of diabetes, and the screening methods used for the detection of glucose intolerance in women with PCOS. Few mechanisms can explain IR in women with PCOS such as obesity, insulin receptor signaling defects, and inhibition of insulin-mediated glucose uptake in adipocytes. Women with PCOS have additional risk factors for the development of glucose intolerance such as family history of diabetes, use of oral contraceptives, anovulation, and age. The Androgen Society in 2007 and the Endocrine Society in 2013 recommended using oral glucose tolerance test as a screening tool for abnormal glucose tolerance in all women with PCOS. The approach to detection of glucose intolerance among women with PCOS varies among health care providers. Large prospective studies are still needed for the development of guidelines with strong evidence. When assessing risk of future diabetes in women with PCOS, it is important to take into account the method used for screening as well as other risk factors that these women might have.

  10. Pathophysiology, risk factors, and screening methods for prediabetes in women with polycystic ovary syndrome

    PubMed Central

    Gourgari, Evgenia; Spanakis, Elias; Dobs, Adrian Sandra

    2016-01-01

    Polycystic ovary syndrome (PCOS) is a syndrome associated with insulin resistance (IR), obesity, infertility, and increased cardiometabolic risk. This is a descriptive review of several mechanisms that can explain the IR among women with PCOS, other risk factors for the development of diabetes, and the screening methods used for the detection of glucose intolerance in women with PCOS. Few mechanisms can explain IR in women with PCOS such as obesity, insulin receptor signaling defects, and inhibition of insulin-mediated glucose uptake in adipocytes. Women with PCOS have additional risk factors for the development of glucose intolerance such as family history of diabetes, use of oral contraceptives, anovulation, and age. The Androgen Society in 2007 and the Endocrine Society in 2013 recommended using oral glucose tolerance test as a screening tool for abnormal glucose tolerance in all women with PCOS. The approach to detection of glucose intolerance among women with PCOS varies among health care providers. Large prospective studies are still needed for the development of guidelines with strong evidence. When assessing risk of future diabetes in women with PCOS, it is important to take into account the method used for screening as well as other risk factors that these women might have. PMID:27570464

  11. Novel microscopy-based screening method reveals regulators of contact-dependent intercellular transfer

    PubMed Central

    Michael Frei, Dominik; Hodneland, Erlend; Rios-Mondragon, Ivan; Burtey, Anne; Neumann, Beate; Bulkescher, Jutta; Schölermann, Julia; Pepperkok, Rainer; Gerdes, Hans-Hermann; Kögel, Tanja

    2015-01-01

    Contact-dependent intercellular transfer (codeIT) of cellular constituents can have functional consequences for recipient cells, such as enhanced survival and drug resistance. Pathogenic viruses, prions and bacteria can also utilize this mechanism to spread to adjacent cells and potentially evade immune detection. However, little is known about the molecular mechanism underlying this intercellular transfer process. Here, we present a novel microscopy-based screening method to identify regulators and cargo of codeIT. Single donor cells, carrying fluorescently labelled endocytic organelles or proteins, are co-cultured with excess acceptor cells. CodeIT is quantified by confocal microscopy and image analysis in 3D, preserving spatial information. An siRNA-based screening using this method revealed the involvement of several myosins and small GTPases as codeIT regulators. Our data indicates that cellular protrusions and tubular recycling endosomes are important for codeIT. We automated image acquisition and analysis to facilitate large-scale chemical and genetic screening efforts to identify key regulators of codeIT. PMID:26271723

  12. A new versatile microarray-based method for high throughput screening of carbohydrate-active enzymes.

    PubMed

    Vidal-Melgosa, Silvia; Pedersen, Henriette L; Schückel, Julia; Arnal, Grégory; Dumon, Claire; Amby, Daniel B; Monrad, Rune Nygaard; Westereng, Bjørge; Willats, William G T

    2015-04-03

    Carbohydrate-active enzymes have multiple biological roles and industrial applications. Advances in genome and transcriptome sequencing together with associated bioinformatics tools have identified vast numbers of putative carbohydrate-degrading and -modifying enzymes including glycoside hydrolases and lytic polysaccharide monooxygenases. However, there is a paucity of methods for rapidly screening the activities of these enzymes. By combining the multiplexing capacity of carbohydrate microarrays with the specificity of molecular probes, we have developed a sensitive, high throughput, and versatile semiquantitative enzyme screening technique that requires low amounts of enzyme and substrate. The method can be used to assess the activities of single enzymes, enzyme mixtures, and crude culture broths against single substrates, substrate mixtures, and biomass samples. Moreover, we show that the technique can be used to analyze both endo-acting and exo-acting glycoside hydrolases, polysaccharide lyases, carbohydrate esterases, and lytic polysaccharide monooxygenases. We demonstrate the potential of the technique by identifying the substrate specificities of purified uncharacterized enzymes and by screening enzyme activities from fungal culture broths. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  13. A New Versatile Microarray-based Method for High Throughput Screening of Carbohydrate-active Enzymes*

    PubMed Central

    Vidal-Melgosa, Silvia; Pedersen, Henriette L.; Schückel, Julia; Arnal, Grégory; Dumon, Claire; Amby, Daniel B.; Monrad, Rune Nygaard; Westereng, Bjørge; Willats, William G. T.

    2015-01-01

    Carbohydrate-active enzymes have multiple biological roles and industrial applications. Advances in genome and transcriptome sequencing together with associated bioinformatics tools have identified vast numbers of putative carbohydrate-degrading and -modifying enzymes including glycoside hydrolases and lytic polysaccharide monooxygenases. However, there is a paucity of methods for rapidly screening the activities of these enzymes. By combining the multiplexing capacity of carbohydrate microarrays with the specificity of molecular probes, we have developed a sensitive, high throughput, and versatile semiquantitative enzyme screening technique that requires low amounts of enzyme and substrate. The method can be used to assess the activities of single enzymes, enzyme mixtures, and crude culture broths against single substrates, substrate mixtures, and biomass samples. Moreover, we show that the technique can be used to analyze both endo-acting and exo-acting glycoside hydrolases, polysaccharide lyases, carbohydrate esterases, and lytic polysaccharide monooxygenases. We demonstrate the potential of the technique by identifying the substrate specificities of purified uncharacterized enzymes and by screening enzyme activities from fungal culture broths. PMID:25657012

  14. New multiplex PCR methods for rapid screening of genetically modified organisms in foods

    PubMed Central

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products. PMID:26257724

  15. New multiplex PCR methods for rapid screening of genetically modified organisms in foods.

    PubMed

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  16. Comparison of different screening methods for blood pressure disorders in children and adolescents.

    PubMed

    Mourato, Felipe Alves; Lima Filho, José Luiz; Mattos, Sandra da Silva

    2015-01-01

    To compare different methods of screening for blood pressure disorders in children and adolescents. A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  17. Use of the blue cotton screen method with endoscopy to detect occult esophageal foreign bodies

    PubMed Central

    Xia, Yan; Zhang, Fan; Xu, Weiran

    2017-01-01

    More than 20,000 cases of upper gastrointestinal foreign bodies (FBs) have been reported in the last 5 years in China. Early detection and treatment is vital in these patients. Differential diagnosis of esophageal injury and occult esophageal foreign bodies is challenging, particularly in the case of non-radio-opaque foreign bodies. A diagnostic technique with high accuracy and low risk is needed for clinical practice. We describe successful use of the “blue cotton screen method” to detect esophageal foreign bodies in 2 patients. The advantages and disadvantages of various diagnostic modalities in the management of patients with foreign body ingestion are presented. This technique is safer and more effective than traditional methods for foreign body impaction in the esophageal cavity. It could be applied for screening and in the differential diagnosis of esophageal injury and FBs in the esophageal lumen. PMID:29362659

  18. Analysis Of Volatile Fingerprints: A Rapid Screening Method For Antifungal Agents For Efficacy Against Dermatophytes

    NASA Astrophysics Data System (ADS)

    Naraghi, Kamran; Sahgal, Natasha; Adriaans, Beverley; Barr, Hugh; Magan, Naresh

    2009-05-01

    The potential of using an electronic nose (E. nose) for rapid screening dermatophytes to antifungal agents was studied. In vitro, the 50 and 90% effective concentration (EC) values of five antifungal agents for T. rubrum and T. mentagrophytes were obtained by mycelial growth assays. Then, the qualitative volatile production patterns of the growth responses of these fungi to these values were incorporated into solid medium were analysed after 96-120 hrs incubation at 25° C using headspace analyses. Overall, results, using PCA and CA demonstrated that it is possible to differentiate between various treatments within 96-120 hrs. This study showed that potential exists for using qualitative volatile patterns as a rapid screening method for antifungal agents for microorganism. This approach could also facilitate the monitoring of antimicrobial drug activities and infection control programmes and perhaps drug resistance build up in microbial species.

  19. From Classical to High Throughput Screening Methods for Feruloyl Esterases: A Review.

    PubMed

    Ramírez-Velasco, Lorena; Armendáriz-Ruiz, Mariana; Rodríguez-González, Jorge Alberto; Müller-Santos, Marcelo; Asaff-Torres, Ali; Mateos-Díaz, Juan Carlos

    2016-01-01

    Feruloyl esterases (FAEs) are a diverse group of hydrolases widely distributed in plants and microorganisms which catalyzes the cleavage and formation of ester bonds between plant cell wall polysaccharides and phenolic acids. FAEs have gained importance in biofuel, medicine and food industries due to their capability of acting on a large range of substrates for cleaving ester bonds and synthesizing highadded value molecules through esterification and transesterification reactions. During the past two decades extensive studies have been carried out on the production, characterization and classification of FAEs, however only a few reports of suitable High Throughput Screening assays for this kind of enzymes have been reported. This review is focused on a concise but complete revision of classical to High Throughput Screening methods for FAEs, highlighting its advantages and disadvantages, and finally suggesting future perspectives for this important research field.

  20. Preparation of superhydrophobic copper surface by a novel silk-screen printing aided electrochemical machining method

    NASA Astrophysics Data System (ADS)

    Yan, X. Y.; Chen, G. X.; Liu, J. W.

    2018-03-01

    A kind of superhydrophobic copper surface with micro-nanocomposite structure has been successfully fabricated by employing a silk-screen printing aided electrochemical machining method. At first silk-screen printing technology has been used to form a column point array mask, and then the microcolumn array would be fabricated by electrochemical machining (ECM) effect. In this study, the drop contact angles have been studied and scanning electron microscopy (SEM) has been used to study the surface characteristic of the workpiece. The experiment results show that the micro-nanocomposite structure with cylindrical array can be successfully fabricated on the metal surface. And the maximum contact angle is 151° when the fluoroalkylsilane ethanol solution was used to modify the machined surface in this study.

  1. Danish method study on cervical screening in women offered HPV vaccination as girls (Trial23): a study protocol.

    PubMed

    Thamsborg, Lise Holst; Andersen, Berit; Larsen, Lise Grupe; Christensen, Jette; Johansen, Tonje; Hariri, Jalil; Christiansen, Sanne; Rygaard, Carsten; Lynge, Elsebeth

    2018-05-26

    The first birth cohorts of women offered human papillomavirus (HPV) vaccination as girls are now entering cervical screening. However, there is no international consensus on how to screen HPV vaccinated women. These women are better protected against cervical cancer and could therefore be offered less intensive screening. Primary HPV testing is more sensitive than cytology, allowing for a longer screening interval. The aim of Trial23 is to investigate if primary HPV testing with cytology triage of HPV positive samples is a reasonable screening scheme for women offered HPV vaccination as girls. Trial23 is a method study embedded in the existing cervical screening programme in four out of five Danish regions. Without affecting the screening programme, women born in 1994 are randomised to present screening with liquid-based cytology every third year (present programme arm) or present screening plus an HPV test (HPV arm). The study started 1 February 2017 and will run over three screening rounds corresponding to 7-8 years. The primary endpoint is cervical intraepithelial neoplasia grade 3 or above. The trial is undertaken as a non-inferiority study including intention-to-treat and per-protocol analyses. The potential effect of primary HPV screening with a 6-year interval will be calculated from the observed data. The study protocol has been submitted to the ethical committee and deemed a method study. All women are screened according to routine guidelines. The study will contribute new evidence on the future screening of HPV vaccinated birth cohorts of women. All results will be published in open-access journal. NCT03049553; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Spectroscopic and Spectrometric Methods Used for the Screening of Certain Herbal Food Supplements Suspected of Adulteration

    PubMed Central

    Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena

    2017-01-01

    Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims. PMID:28761827

  3. A Rapid and Efficient Screening Method for Antibacterial Compound-Producing Bacteria.

    PubMed

    Hettiarachchi, Sachithra; Lee, Su-Jin; Lee, Youngdeuk; Kwon, Young-Kyung; De Zoysa, Mahanama; Moon, Song; Jo, Eunyoung; Kim, Taeho; Kang, Do-Hyung; Heo, Soo-Jin; Oh, Chulhong

    2017-08-28

    Antibacterial compounds are widely used in the treatment of human and animal diseases. The overuse of antibiotics has led to a rapid rise in the prevalence of drug-resistant bacteria, making the development of new antibacterial compounds essential. This study focused on developing a fast and easy method for identifying marine bacteria that produce antibiotic compounds. Eight randomly selected marine target bacterial species ( Agrococcus terreus, Bacillus algicola, Mesoflavibacter zeaxanthinifaciens, Pseudoalteromonas flavipulchra, P. peptidolytica, P. piscicida, P. rubra , and Zunongwangia atlantica ) were tested for production of antibacterial compounds against four strains of test bacteria ( B. cereus, B. subtilis, Halomonas smyrnensis , and Vibrio alginolyticus ). Colony picking was used as the primary screening method. Clear zones were observed around colonies of P. flavipulchra, P. peptidolytica, P. piscicida , and P. rubra tested against B. cereus, B. subtilis , and H. smyrnensis . The efficiency of colony scraping and broth culture methods for antimicrobial compound extraction was also compared using a disk diffusion assay. P. peptidolytica, P. piscicida , and P. rubra showed antagonistic activity against H. smyrnensis, B. cereus , and B. subtilis , respectively, only in the colony scraping method. Our results show that colony picking and colony scraping are effective, quick, and easy methods of screening for antibacterial compound-producing bacteria.

  4. Finite Temperature Densities via the S-Function Method with Application to Electron Screening in Plasmas

    NASA Astrophysics Data System (ADS)

    Watrous, Mitchell James

    1997-12-01

    A new approach to the Green's-function method for the calculation of equilibrium densities within the finite temperature, Kohn-Sham formulation of density functional theory is presented, which extends the method to all temperatures. The contour of integration in the complex energy plane is chosen such that the density is given by a sum of Green's function differences evaluated at the Matsubara frequencies, rather than by the calculation and summation of Kohn-Sham single-particle wave functions. The Green's functions are written in terms of their spectral representation and are calculated as the solutions of their defining differential equations. These differential equations are boundary value problems as opposed to the standard eigenvalue problems. For large values of the complex energy, the differential equations are further simplified from second to first-order by writing the Green's functions in terms of logarithmic derivatives. An asymptotic expression for the Green's functions is derived, which allows the sum over Matsubara poles to be approximated. The method is applied to the screening of nuclei by electrons in finite temperature plasmas. To demonstrate the method's utility, and to illustrate its advantages, the results of previous wave function type calculations for protons and neon nuclei are reproduced. The method is also used to formulate a new screening model for fusion reactions in the solar core, and the predicted reaction rate enhancements factors are compared with existing models.

  5. Survey of South African fruit juices using a fast screening HILIC-MS method.

    PubMed

    Stander, Marietjie A; Kühn, Wernich; Hiten, Nicholas F

    2013-01-01

    Adulteration of fruit juices--by the addition of sugar or other less expensive fruit juices as well as preservatives, artificial sweeteners and colours--was tested for by using a developed screening method. The method employs hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) using electrospray ionisation in the negative mode and ultraviolet light detection. Different fruit juices can be differentiated by the content of marker compounds like sorbitol, certain phenolic molecules and their saccharide profile. This method was used to test 46 fruit juice samples from the retail market as well as 12 control samples. The study focused on the main types of fruit juices consumed on the South African market including apple, orange, grape and blends of these juices with other fruits like mango, pear and guava. Overall, the 46 samples tested mostly agreed with label claims. One grape juice sample was adulterated, probably with apple juice. Natamycin above the legal limits was found in two samples. In addition, two samples contained natamycin and one sample benzoate without it being indicated on the label. The method is well suited as a quick screening method for fruit juice adulteration and if used routinely would reduce fruit juice adulteration without the cost of the current array of tests needed for authenticity testing.

  6. Spectroscopic and Spectrometric Methods Used for the Screening of Certain Herbal Food Supplements Suspected of Adulteration.

    PubMed

    Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena

    2017-06-01

    Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims.

  7. Screening of groundwater remedial alternatives for brownfield sites: a comprehensive method integrated MCDA with numerical simulation.

    PubMed

    Li, Wei; Zhang, Min; Wang, Mingyu; Han, Zhantao; Liu, Jiankai; Chen, Zhezhou; Liu, Bo; Yan, Yan; Liu, Zhu

    2018-06-01

    Brownfield sites pollution and remediation is an urgent environmental issue worldwide. The screening and assessment of remedial alternatives is especially complex owing to its multiple criteria that involves technique, economy, and policy. To help the decision-makers selecting the remedial alternatives efficiently, the criteria framework conducted by the U.S. EPA is improved and a comprehensive method that integrates multiple criteria decision analysis (MCDA) with numerical simulation is conducted in this paper. The criteria framework is modified and classified into three categories: qualitative, semi-quantitative, and quantitative criteria, MCDA method, AHP-PROMETHEE (analytical hierarchy process-preference ranking organization method for enrichment evaluation) is used to determine the priority ranking of the remedial alternatives and the solute transport simulation is conducted to assess the remedial efficiency. A case study was present to demonstrate the screening method in a brownfield site in Cangzhou, northern China. The results show that the systematic method provides a reliable way to quantify the priority of the remedial alternatives.

  8. SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

    SciTech Connect

    Samuel, D; Testa, M; Park, Y

    Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separablemore » into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.« less

  9. An in vitro screening method to evaluate chemicals as potential chemotherapeutants to control Aeromonas hydrophila infection in channel catfish

    USDA-ARS?s Scientific Manuscript database

    Using catfish gill cells G1B and four chemicals (hydrogen peroxide, sodium chloride, potassium permanganate, and D-mannose), the feasibility of using an in vitro screening method to identify potential effective chemotherapeutants was evaluated in this study. In vitro screening results revealed that,...

  10. Comparison of Instructional Methods for Screening, Brief Intervention, and Referral to Treatment for Substance Use in Nursing Education.

    PubMed

    Knopf-Amelung, Sarah; Gotham, Heather; Kuofie, Araba; Young, Pamela; Manney Stinson, Ronalda; Lynn, Jolene; Barker, Kendra; Hildreth, Jessica

    Most nursing programs lack curriculum on substance use. This project evaluated 3 didactic instructional methods for teaching baccalaureate nursing students about screening, brief intervention, and referral to treatment for substance use. In-person, asynchronous narrated slides and interactive online instructional methods were all effective in developing students' competency; however, active learning methods (in-person and interactive online course) were more effective in changing students' attitudes about their role in screening and intervening for drug use.

  11. A Systematic Evaluation of Field-Based Screening Methods for the Assessment of Anterior Cruciate Ligament (ACL) Injury Risk.

    PubMed

    Fox, Aaron S; Bonacci, Jason; McLean, Scott G; Spittle, Michael; Saunders, Natalie

    2016-05-01

    Laboratory-based measures provide an accurate method to identify risk factors for anterior cruciate ligament (ACL) injury; however, these methods are generally prohibitive to the wider community. Screening methods that can be completed in a field or clinical setting may be more applicable for wider community use. Examination of field-based screening methods for ACL injury risk can aid in identifying the most applicable method(s) for use in these settings. The objective of this systematic review was to evaluate and compare field-based screening methods for ACL injury risk to determine their efficacy of use in wider community settings. An electronic database search was conducted on the SPORTDiscus™, MEDLINE, AMED and CINAHL databases (January 1990-July 2015) using a combination of relevant keywords. A secondary search of the same databases, using relevant keywords from identified screening methods, was also undertaken. Studies identified as potentially relevant were independently examined by two reviewers for inclusion. Where consensus could not be reached, a third reviewer was consulted. Original research articles that examined screening methods for ACL injury risk that could be undertaken outside of a laboratory setting were included for review. Two reviewers independently assessed the quality of included studies. Included studies were categorized according to the screening method they examined. A description of each screening method, and data pertaining to the ability to prospectively identify ACL injuries, validity and reliability, recommendations for identifying 'at-risk' athletes, equipment and training required to complete screening, time taken to screen athletes, and applicability of the screening method across sports and athletes were extracted from relevant studies. Of 1077 citations from the initial search, a total of 25 articles were identified as potentially relevant, with 12 meeting all inclusion/exclusion criteria. From the secondary search, eight

  12. Isotonic Regression Based-Method in Quantitative High-Throughput Screenings for Genotoxicity

    PubMed Central

    Fujii, Yosuke; Narita, Takeo; Tice, Raymond Richard; Takeda, Shunich

    2015-01-01

    Quantitative high-throughput screenings (qHTSs) for genotoxicity are conducted as part of comprehensive toxicology screening projects. The most widely used method is to compare the dose-response data of a wild-type and DNA repair gene knockout mutants, using model-fitting to the Hill equation (HE). However, this method performs poorly when the observed viability does not fit the equation well, as frequently happens in qHTS. More capable methods must be developed for qHTS where large data variations are unavoidable. In this study, we applied an isotonic regression (IR) method and compared its performance with HE under multiple data conditions. When dose-response data were suitable to draw HE curves with upper and lower asymptotes and experimental random errors were small, HE was better than IR, but when random errors were big, there was no difference between HE and IR. However, when the drawn curves did not have two asymptotes, IR showed better performance (p < 0.05, exact paired Wilcoxon test) with higher specificity (65% in HE vs. 96% in IR). In summary, IR performed similarly to HE when dose-response data were optimal, whereas IR clearly performed better in suboptimal conditions. These findings indicate that IR would be useful in qHTS for comparing dose-response data. PMID:26673567

  13. Validation of a Method To Screen for Pulmonary Hypertension in Advanced Idiopathic Pulmonary Fibrosis*

    PubMed Central

    Zisman, David A.; Karlamangla, Arun S.; Kawut, Steven M.; Shlobin, Oksana A.; Saggar, Rajeev; Ross, David J.; Schwarz, Marvin I.; Belperio, John A.; Ardehali, Abbas; Lynch, Joseph P.; Nathan, Steven D.

    2008-01-01

    Background We have developed a method to screen for pulmonary hypertension (PH) in idiopathic pulmonary fibrosis (IPF) patients, based on a formula to predict mean pulmonary artery pressure (MPAP) from standard lung function measurements. The objective of this study was to validate this method in a separate group of IPF patients. Methods Cross-sectional study of 60 IPF patients from two institutions. The accuracy of the MPAP estimation was assessed by examining the correlation between the predicted and measured MPAPs and the magnitude of the estimation error. The discriminatory ability of the method for PH was assessed using the area under the receiver operating characteristic curve (AUC). Results There was strong correlation in the expected direction between the predicted and measured MPAPs (r = 0.72; p < 0.0001). The estimated MPAP was within 5 mm Hg of the measured MPAP 72% of the time. The AUC for predicting PH was 0.85, and did not differ by institution. A formula-predicted MPAP > 21 mm Hg was associated with a sensitivity, specificity, positive predictive value, and negative predictive value of 95%, 58%, 51%, and 96%, respectively, for PH defined as MPAP from right-heart catheterization > 25 mm Hg. Conclusions A prediction formula for MPAP using standard lung function measurements can be used to screen for PH in IPF patients. PMID:18198245

  14. Screening DNA chip and event-specific multiplex PCR detection methods for biotech crops.

    PubMed

    Lee, Seong-Hun

    2014-11-01

    There are about 80 biotech crop events that have been approved by safety assessment in Korea. They have been controlled by genetically modified organism (GMO) and living modified organism (LMO) labeling systems. The DNA-based detection method has been used as an efficient scientific management tool. Recently, the multiplex polymerase chain reaction (PCR) and DNA chip have been developed as simultaneous detection methods for several biotech crops' events. The event-specific multiplex PCR method was developed to detect five biotech maize events: MIR604, Event 3272, LY 038, MON 88017 and DAS-59122-7. The specificity was confirmed and the sensitivity was 0.5%. The screening DNA chip was developed from four endogenous genes of soybean, maize, cotton and canola respectively along with two regulatory elements and seven genes: P35S, tNOS, pat, bar, epsps1, epsps2, pmi, cry1Ac and cry3B. The specificity was confirmed and the sensitivity was 0.5% for four crops' 12 events: one soybean, six maize, three cotton and two canola events. The multiplex PCR and DNA chip can be available for screening, gene-specific and event-specific analysis of biotech crops as efficient detection methods by saving on workload and time. © 2014 Society of Chemical Industry. © 2014 Society of Chemical Industry.

  15. High prevalence of bacteriuria in pregnancy and its screening methods in north India.

    PubMed

    Bandyopadhyay, Sutapa; Thakur, J S; Ray, Pallab; Kumar, Rajesh

    2005-05-01

    The study aims at finding out the prevalence of bacteruria in pregnancy in an urban setting and ascertaining methods to screen them in primary care clinics. A total of 1 61 pregnant ladies visiting a primary care clinic were screened for bacteriuria based on the symptomatology. Urine culture was done to know the prevalence of bacteriuria. Sensitivities and specificities were calculated for each symptom and risk assessment. A score card was developed based on combination of positive risk assessment and constellation of symptoms. Prevalence of symptomatic and asymptomatic bacteriuria was found to be 19.87% and 4.34% respectively. Prevalence of bacteriuria was significantly high among those who had intercourse more frequently and those with less water intake. Those with a score of more than or equal to 4, as per score card were 60% more likely to suffer from bacteriuria. When combined with microscopic examination for leucocytes on positively screened, the positive predictive value was found to be 89%. It is concluded that prevalence of symptomatic bacteriuria is common among pregnant women. Syndromic management of cases on the basis of score card is helpful in resource constraint areas. This may be combined with microscopic examination of urine to entail rational use of antibiotics.

  16. Microplate-based method to screen inhibitors of isozymes of cyclic nucleotide phosphodiesterase fused to SUMO.

    PubMed

    Chen, Chunyan; Liu, Miaomiao; Wu, Jing; Yang, Xiaolan; Hu, Xiaolei; Pu, Jun; Long, Gaobo; Xie, Yanling; Jiang, Hairong; Yuan, Yonghua; Liao, Fei

    2014-12-01

    The feasibility for microplate-based screening of inhibitors of isozymes of cyclic nucleotide phosphodiesterase (PDE) was tested via the coupled action of a phosphatase on adenosine-5'-monophosphate and an improved malachite green assay of phosphate. Human full-length PDE4B2 and truncated mutant (152-528aa) were expressed in Escherichia coli via fusion to SUMO, which after purification through Ni-NTA column exhibited specific activities >0.017 U mg(-1). In the presence of proteins <30 mg L(-1), absorbance for 10 µΜ phosphate was measurable; a PDE isozyme of specific activity over 0.008 U mg(-1) after reaction for 20 min thus suited for microplate-based screening of inhibitors. By using Biotek ELX 800 microplate reader, affinities of two forms of PEDE4B2 for cAMP, rolipram and papaverine varied over three magnitudes and were consistent with those by routine assay, respectively. Hence, the proposed method was promising for high-throughput-screening of inhibitors of phosphate-releasing enzymes bearing specific activities over 0.008 U mg(-1).

  17. Flexible methods for segmentation evaluation: Results from CT-based luggage screening

    PubMed Central

    Karimi, Seemeen; Jiang, Xiaoqian; Cosman, Pamela; Martz, Harry

    2017-01-01

    BACKGROUND Imaging systems used in aviation security include segmentation algorithms in an automatic threat recognition pipeline. The segmentation algorithms evolve in response to emerging threats and changing performance requirements. Analysis of segmentation algorithms’ behavior, including the nature of errors and feature recovery, facilitates their development. However, evaluation methods from the literature provide limited characterization of the segmentation algorithms. OBJECTIVE To develop segmentation evaluation methods that measure systematic errors such as oversegmentation and undersegmentation, outliers, and overall errors. The methods must measure feature recovery and allow us to prioritize segments. METHODS We developed two complementary evaluation methods using statistical techniques and information theory. We also created a semi-automatic method to define ground truth from 3D images. We applied our methods to evaluate five segmentation algorithms developed for CT luggage screening. We validated our methods with synthetic problems and an observer evaluation. RESULTS Both methods selected the same best segmentation algorithm. Human evaluation confirmed the findings. The measurement of systematic errors and prioritization helped in understanding the behavior of each segmentation algorithm. CONCLUSIONS Our evaluation methods allow us to measure and explain the accuracy of segmentation algorithms. PMID:24699346

  18. In-vivo corneal pulsation in relation to in-vivo intraocular pressure and corneal biomechanics assessed in-vitro. An animal pilot study.

    PubMed

    Rogala, Maja M; Danielewska, Monika E; Antończyk, Agnieszka; Kiełbowicz, Zdzisław; Rogowska, Marta E; Kozuń, Marta; Detyna, Jerzy; Iskander, D Robert

    2017-09-01

    The aim was to ascertain whether the characteristics of the corneal pulse (CP) measured in-vivo in a rabbit eye change after short-term artificial increase of intraocular pressure (IOP) and whether they correlate with corneal biomechanics assessed in-vitro. Eight New Zealand white rabbits were included in this study and were anesthetized. In-vivo experiments included simultaneous measurements of the CP signal, registered with a non-contact method, IOP, intra-arterial blood pressure, and blood pulse (BPL), at the baseline and short-term elevated IOP. Afterwards, thickness of post-mortem corneas was determined and then uniaxial tensile tests were conducted leading to estimates of their Young's modulus (E). At the baseline IOP, backward stepwise regression analyses were performed in which successively the ocular biomechanical, biometric and cardiovascular predictors were separately taken into account. Results of the analysis revealed that the 3rd CP harmonic can be statistically significantly predicted by E and central corneal thickness (Models: R 2  = 0.662, p < 0.005 and R 2  = 0.832, p < 0.001 for the signal amplitude and power, respectively). The 1st CP harmonic can be statistically significantly predicted by the amplitude and power of the 1st BPL harmonic (Models: R 2  = 0.534, p = 0.015 and R 2  = 0.509, p < 0.018, respectively). For elevated IOP, non-parametric analysis indicated significant differences for the power of the 1st CP harmonic (Kruskal-Wallis test; p = 0.031) and for the mean, systolic and diastolic blood pressures (p = 0.025, p = 0.019, p = 0.033, respectively). In conclusion, for the first time, the association between parameters of the CP signal in-vivo and corneal biomechanics in-vitro was confirmed. In particular, spectral analysis revealed that higher amplitude and power of the 3rd CP harmonic indicates higher corneal stiffness, while the 1st CP harmonic correlates positively with the corresponding harmonic of the BPL

  19. Postal urine specimens: are they a feasible method for genital chlamydial infection screening?

    PubMed Central

    Macleod, J; Rowsell, R; Horner, P; Crowley, T; Caul, E O; Low, N; Smith, G D

    1999-01-01

    BACKGROUND: A United Kingdom (UK) screening programme for Chlamydia trachomatis has recently been announced. Pilot projects involving the opportunistic testing of women attending health facilities are due to commence in several sites. There is a danger that this approach will fail to obtain adequate population coverage. The alternative--true systematic population screening--is generally assumed to be unfeasible. Studies in Denmark using postal urine specimens have challenged this assumption. No such studies have been reported from the UK. AIM: To assess the potential of urine specimens sent by post as the basis for a UK population screening strategy for genital chlamydial infection. METHOD: Two hundred patients (100 men, 100 women) aged 18 to 45 years were randomly sampled from the list of one urban group practice. Subjects were mailed an explanatory letter, a urine sample container, a sexual lifestyle questionnaire, and a prepaid return envelope. Non-responders were contacted by telephone; persistent non-responders were visited at home. Samples were tested for Chlamydia by DNA amplification and enzyme immunoassay. RESULTS: Sixty-four (32%) subjects were no longer living at their GP registered address. Of the remaining 136, 126 (93%) responded to the survey and 113 (83%) accepted the request for a urine sample and completed a questionnaire. Acceptance rates were similar for men and women and across age groups. Four samples (3%) were Chlamydia positive. CONCLUSION: Home mailed urine specimen collection in conjunction with a self-completed postal questionnaire is feasible. This could provide a viable basis both for determining population Chlamydia prevalence and for a UK Chlamydia population screening strategy. Overall cost effectiveness of such a strategy will depend on the cost of the test used. Comparative performance characteristics of the different currently available tests in this setting have yet to be fully determined. PMID:10562745

  20. Using quality improvement methods to optimize resources and maximize productivity in an anesthesia screening and consultation clinic.

    PubMed

    Varughese, Anna M; Hagerman, Nancy; Townsend, Mari E

    2013-07-01

    The anesthesia preoperative screening and evaluation of a patient prior to surgery is a critical element in the safe and effective delivery of anesthesia care. In this era of increased focus on cost containment, many anesthesia practices are looking for ways to maximize productivity while maintaining the quality of the preoperative evaluation process by harnessing and optimizing all available resources. We sought to develop a Nurse Practitioner-assisted Preoperative Anesthesia Screening process using quality improvement methods with the goal of maintaining the quality of the screening process, while at the same time redirecting anesthesiologists time for the provision of nonoperating room (OR) anesthesia. The Nurse practitioner (NP) time (approximately 10 h per week) directed to this project was gained as a result of an earlier resource utilization improvement project within the Department of Anesthesia. The goal of this improvement project was to increase the proportion of patient anesthesia screens conducted by NPs to 50% within 6 months. After discussion with key stakeholders of the process, a multidisciplinary improvement team identified a set of operational factors (key drivers) believed to be important to the success of the preoperative anesthesia screening process. These included the development of dedicated NP time for daily screening, NP competency and confidence with the screening process, effective mentoring by anesthesiologists, standardization of screening process, and communication with stakeholders of the process, that is, surgeons. These key drivers focused on the development of several interventions such as (i) NP education in the preoperative anesthesia screening for consultation process by a series of didactic lectures conducted by anesthesiologists, and NP's shadowing an anesthesiologist during the screening process, (ii) Anesthesiologist mentoring and assessment of NP screenings using the dual screening process whereby both anesthesiologists

  1. Cost-effectiveness of lung cancer screening and treatment methods: a systematic review of systematic reviews.

    PubMed

    Azar, Farbod Ebadifard; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Mazdaki, Alireza; Rezapour, Aziz; Ebrahimi, Parvin; Yousefzadeh, Negar

    2017-06-19

    Due to extensive literature in the field of lung cancer and their heterogeneous results, the aim of this study was to systematically review of systematic reviews studies which reviewed the cost-effectiveness of various lung cancer screening and treatment methods. In this systematic review of systematic reviews study, required data were collected searching the following key words which selected from Mesh: "lung cancer", "lung oncology", "lung Carcinoma", "lung neoplasm", "lung tumors", "cost- effectiveness", "systematic review" and "Meta-analysis". The following databases were searched: PubMed, Cochrane Library electronic databases, Google Scholar, and Scopus. Two reviewers (RA and A-AS) evaluated the articles according to the checklist of "assessment of multiple systematic reviews" (AMSTAR) tool. Overall, information of 110 papers was discussed in eight systematic reviews. Authors focused on cost-effectiveness of lung cancer treatments in five systematic reviews. Targeted therapy options (bevacizumab, Erlotinib and Crizotinib) show an acceptable cost-effectiveness. Results of three studies failed to show cost-effectiveness of screening methods. None of the studies had used the meta-analysis method. The Quality of Health Economic Studies (QHES) tool and Drummond checklist were mostly used in assessing the quality of articles. Most perspective was related to the Payer (64 times) and the lowest was related to Social (11times). Most cases referred to Incremental analysis (82%) and also the lowest point of referral was related to Discounting (in 49% of the cases). The average quality score of included studies was calculated 9.2% from 11. Targeted therapy can be an option for the treatment of lung cancer. Evaluation of the cost-effectiveness of computerized tomographic colonography (CTC) in lung cancer screening is recommended. The perspective of the community should be more taken into consideration in studies of cost-effectiveness. Paying more attention to the topic of

  2. Non invasive diagnostic methods for better screening of peripheral arterial disease.

    PubMed

    Nirala, Neelamshobha; Periyasamy, R; Kumar, Awanish

    2018-05-16

    Peripheral arterial disease (PAD) is a common circulatory problem in which narrowed arteries reduce blood flow to extremities usually legs. It does not receive enough blood flow to keep up with demand. This causes symptoms, most notably leg pain while walking which is known as claudication. It is a common manifestation of type II Diabetes, but the relationship between other vascular diseases and lower limb (LL)-PAD has been poorly understood and investigated. When assessing a patient with clinically LLPAD, two questions are in order to establish a diagnosis: one is non-invasive testing and other is invasive. Invasive methods are painful and get so bad that some people need to have a leg surgery. People with Diabetes are at increased risk for amputation and it is used only when the damage is very severe. Diagnosis of LLPAD begins with a physical examination, patient history, certain questionnaire and non invasive mode of diagnosis is started for the screening of patients. Clinicians check for weak pulses in the legs and then decide for further diagnosis. Paper discusses the prevalence of LLPAD worldwide and in India along with the clinical effectiveness and limitations of these methods in case of Diabetes. The focus of this review is to discuss only those non invasive methods which are widely used for screening of LLPAD like Ankle brachial index (ABI), Toe brachial Index (TBI), and use of photoplethysmogram (PPG) specially in case of Diabetic patients. Also, this paper gives an overview of the work done using ABI, TBI, and PPG for detection of LLPAD. These tests are not painful and could be performed in a cost-effective manner to avoid delays in screening/diagnosis and also reduce costs. Copyright © 2018. Published by Elsevier Inc.

  3. Knowledge-Based Methods To Train and Optimize Virtual Screening Ensembles

    PubMed Central

    2016-01-01

    Ensemble docking can be a successful virtual screening technique that addresses the innate conformational heterogeneity of macromolecular drug targets. Yet, lacking a method to identify a subset of conformational states that effectively segregates active and inactive small molecules, ensemble docking may result in the recommendation of a large number of false positives. Here, three knowledge-based methods that construct structural ensembles for virtual screening are presented. Each method selects ensembles by optimizing an objective function calculated using the receiver operating characteristic (ROC) curve: either the area under the ROC curve (AUC) or a ROC enrichment factor (EF). As the number of receptor conformations, N, becomes large, the methods differ in their asymptotic scaling. Given a set of small molecules with known activities and a collection of target conformations, the most resource intense method is guaranteed to find the optimal ensemble but scales as O(2N). A recursive approximation to the optimal solution scales as O(N2), and a more severe approximation leads to a faster method that scales linearly, O(N). The techniques are generally applicable to any system, and we demonstrate their effectiveness on the androgen nuclear hormone receptor (AR), cyclin-dependent kinase 2 (CDK2), and the peroxisome proliferator-activated receptor δ (PPAR-δ) drug targets. Conformations that consisted of a crystal structure and molecular dynamics simulation cluster centroids were used to form AR and CDK2 ensembles. Multiple available crystal structures were used to form PPAR-δ ensembles. For each target, we show that the three methods perform similarly to one another on both the training and test sets. PMID:27097522

  4. Flexible methods for segmentation evaluation: results from CT-based luggage screening.

    PubMed

    Karimi, Seemeen; Jiang, Xiaoqian; Cosman, Pamela; Martz, Harry

    2014-01-01

    Imaging systems used in aviation security include segmentation algorithms in an automatic threat recognition pipeline. The segmentation algorithms evolve in response to emerging threats and changing performance requirements. Analysis of segmentation algorithms' behavior, including the nature of errors and feature recovery, facilitates their development. However, evaluation methods from the literature provide limited characterization of the segmentation algorithms. To develop segmentation evaluation methods that measure systematic errors such as oversegmentation and undersegmentation, outliers, and overall errors. The methods must measure feature recovery and allow us to prioritize segments. We developed two complementary evaluation methods using statistical techniques and information theory. We also created a semi-automatic method to define ground truth from 3D images. We applied our methods to evaluate five segmentation algorithms developed for CT luggage screening. We validated our methods with synthetic problems and an observer evaluation. Both methods selected the same best segmentation algorithm. Human evaluation confirmed the findings. The measurement of systematic errors and prioritization helped in understanding the behavior of each segmentation algorithm. Our evaluation methods allow us to measure and explain the accuracy of segmentation algorithms.

  5. Gravimetric screening method for fungal decay of paper: inoculation with Trametes versicolor.

    PubMed

    Råberg, Ulrika; Hafrén, Jonas

    2009-10-01

    The European standard test EN 113 for fungal degradation of solid wood has been adapted for degradation of paper by white rot fungus (Trametes versicolor). Fungal degradation of paper sheets may potentially be used for screening different wood preservatives on paper instead of solid wood. The paper samples showed higher relative mass losses compared to wood, and samples pretreated with boric acid, copper sulfate and polymerized linseed oil were successfully tested for biodegradation using the paper sheet method. The results on paper degradation were compared with wood, both as wood blocks (according to standard test) and wood cut in sections forming layered structures mimicking paper layers.

  6. Docking and scoring in virtual screening for drug discovery: methods and applications.

    PubMed

    Kitchen, Douglas B; Decornez, Hélène; Furr, John R; Bajorath, Jürgen

    2004-11-01

    Computational approaches that 'dock' small molecules into the structures of macromolecular targets and 'score' their potential complementarity to binding sites are widely used in hit identification and lead optimization. Indeed, there are now a number of drugs whose development was heavily influenced by or based on structure-based design and screening strategies, such as HIV protease inhibitors. Nevertheless, there remain significant challenges in the application of these approaches, in particular in relation to current scoring schemes. Here, we review key concepts and specific features of small-molecule-protein docking methods, highlight selected applications and discuss recent advances that aim to address the acknowledged limitations of established approaches.

  7. Chemical screening method for the rapid identification of microbial sources of marine invertebrate-associated metabolites.

    PubMed

    Berrue, Fabrice; Withers, Sydnor T; Haltli, Brad; Withers, Jo; Kerr, Russell G

    2011-03-21

    Marine invertebrates have proven to be a rich source of secondary metabolites. The growing recognition that marine microorganisms associated with invertebrate hosts are involved in the biosynthesis of secondary metabolites offers new alternatives for the discovery and development of marine natural products. However, the discovery of microorganisms producing secondary metabolites previously attributed to an invertebrate host poses a significant challenge. This study describes an efficient chemical screening method utilizing a 96-well plate-based bacterial cultivation strategy to identify and isolate microbial producers of marine invertebrate-associated metabolites.

  8. Studies with the USF/NASA toxicity screening test method - Exercise wheels and oxygen replenishment

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Continuing efforts to improve the University of San Francisco/NASA toxicity screening test method have included the addition of exercise wheels to provide a different measure of incapacitation, and oxygen replenishment to offset any effect of oxygen depletion by the test animals. The addition of exercise wheels limited the number of animals in each test and doubled the required number of tests without any significant improvement in reproducibility. Oxygen replenishment appears to have an effect on survival in the last 5 minutes of the 30-minute test, but the effect is expected to be similar for most materials.

  9. The novel measuring method for screening and assessing chromium content in clothes and shoes materials

    NASA Astrophysics Data System (ADS)

    Salerno-Kochan, R.

    2017-10-01

    The aim of this paper is to propose the bioindicative measuring method for screening and assessing the safety of textile and leather materials in relation to chemical threats. This method is based on toxicological assay in which Tetrahymena pyriformis, unicellular organism belonging to protozoans, is used as a test organism. For the realization of the research goal the sensitivity threshold of test organisms to chromium(VI) solutions was identified. The changes in cell development of test organisms in chromium solutions were registered by colorimetric measurements in the presence of alamarBlue® cell viability reagent. Empirical data enabled to fit logistic curves on the base of which the level of chromium toxicity was estimated. In the second step, harmfulness of aqueous extracts obtained from textile and leather samples containing chromium in relation to test organisms was evaluated. The performed research confirmed the high efficiency of the proposed method in screening and assessing chromium content in clothes and shoes materials and showed possibilities of using it in safety assessment of products with regard to chemical risks.

  10. Innovative approach for in-vivo ablation validation on multimodal images

    NASA Astrophysics Data System (ADS)

    Shahin, O.; Karagkounis, G.; Carnegie, D.; Schlaefer, A.; Boctor, E.

    2014-03-01

    Radiofrequency ablation (RFA) is an important therapeutic procedure for small hepatic tumors. To make sure that the target tumor is effectively treated, RFA monitoring is essential. While several imaging modalities can observe the ablation procedure, it is not clear how ablated lesions on the images correspond to actual necroses. This uncertainty contributes to the high local recurrence rates (up to 55%) after radiofrequency ablative therapy. This study investigates a novel approach to correlate images of ablated lesions with actual necroses. We mapped both intraoperative images of the lesion and a slice through the actual necrosis in a common reference frame. An electromagnetic tracking system was used to accurately match lesion slices from different imaging modalities. To minimize the liver deformation effect, the tracking reference frame was defined inside the tissue by anchoring an electromagnetic sensor adjacent to the lesion. A validation test was performed using a phantom and proved that the end-to-end accuracy of the approach was within 2mm. In an in-vivo experiment, intraoperative magnetic resonance imaging (MRI) and ultrasound (US) ablation images were correlated to gross and histopathology. The results indicate that the proposed method can accurately correlate invivo ablations on different modalities. Ultimately, this will improve the interpretation of the ablation monitoring and reduce the recurrence rates associated with RFA.

  11. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    NASA Astrophysics Data System (ADS)

    Rasmussen, Joachim H.; Hemmsen, Martin C.; Madsen, Signe S.; Hansen, Peter M.; Nielsen, Michael B.; Jensen, Jørgen A.

    2013-03-01

    A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequen- tial beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imag- ing (DRF-THI) in clinical scans. The scan sequence that was implemented on the UltraView system acquires both SASB-THI and DRF-THI simultaneously. Twenty-four simultaneously acquired video sequences of in-vivo abdominal SASB-THI and DRF-THI scans on 3 volunteers of 4 different sections of liver and kidney tissues were created. Videos of the in-vivo scans were presented in double blinded studies to two radiologists for image quality performance scoring. Limitations to the systems transmit stage prevented user defined transmit apodization to be applied. Field II simulations showed that side lobes in SASB could be improved by using Hanning transmit apodization. Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.

  12. Estimation of in-vivo neurotransmitter release by brain microdialysis: the issue of validity.

    PubMed

    Di Chiara, G.; Tanda, G.; Carboni, E.

    1996-11-01

    Although microdialysis is commonly understood as a method of sampling low molecular weight compounds in the extracellular compartment of tissues, this definition appears insufficient to specifically describe brain microdialysis of neurotransmitters. In fact, transmitter overflow from the brain into dialysates is critically dependent upon the composition of the perfusing Ringer. Therefore, the dialysing Ringer not only recovers the transmitter from the extracellular brain fluid but is a main determinant of its in-vivo release. Two types of brain microdialysis are distinguished: quantitative micro-dialysis and conventional microdialysis. Quantitative microdialysis provides an estimate of neurotransmitter concentrations in the extracellular fluid in contact with the probe. However, this information might poorly reflect the kinetics of neurotransmitter release in vivo. Conventional microdialysis involves perfusion at a constant rate with a transmitter-free Ringer, resulting in the formation of a steep neurotransmitter concentration gradient extending from the Ringer into the extracellular fluid. This artificial gradient might be critical for the ability of conventional microdialysis to detect and resolve phasic changes in neurotransmitter release taking place in the implanted area. On the basis of these characteristics, conventional microdialysis of neurotransmitters can be conceptualized as a model of the in-vivo release of neurotransmitters in the brain. As such, the criteria of face-validity, construct-validity and predictive-validity should be applied to select the most appropriate experimental conditions for estimating neurotransmitter release in specific brain areas in relation to behaviour.

  13. A non-contact time-domain scanning brain imaging system: first in-vivo results

    NASA Astrophysics Data System (ADS)

    Mazurenka, M.; Di Sieno, L.; Boso, G.; Contini, D.; Pifferi, A.; Dalla Mora, A.; Tosi, A.; Wabnitz, H.; Macdonald, R.

    2013-06-01

    We present results of first in-vivo tests of an optical non-contact scanning imaging system, intended to study oxidative metabolism related processes in biological tissue by means of time-resolved near-infrared spectroscopy. Our method is a novel realization of the short source-detector separation approach and based on a fast-gated single-photon avalanche diode to detect late photons only. The scanning system is built in quasi-confocal configuration and utilizes polarizationsensitive detection. It scans an area of 4×4 cm2, recording images with 32×32 pixels, thus creating a high density of source-detector pairs. To test the system we performed a range of in vivo measurements of hemodynamic changes in several types of biological tissues, i.e. skin (Valsalva maneuver), muscle (venous and arterial occlusions) and brain (motor and cognitive tasks). Task-related changes in hemoglobin concentrations were clearly detected in skin and muscle. The brain activation shows weaker, but yet detectable changes. These changes were localized in pixels near the motor cortex area (C3). However, it was found that even very short hair substantially impairs the measurement. Thus the applicability of the scanner is limited to hairless parts of body. The results of our first in-vivo tests prove the feasibility of non-contact scanning imaging as a first step towards development of a prototype for biological tissue imaging for various medical applications.

  14. Convenient, sensitive and high-throughput method for screening botanic origin.

    PubMed

    Yuan, Yuan; Jiang, Chao; Liu, Libing; Yu, Shulin; Cui, Zhanhu; Chen, Min; Lin, Shufang; Wang, Shu; Huang, Luqi

    2014-06-23

    In this work, a rapid (within 4-5 h), sensitive and visible new method for assessing botanic origin is developed by combining loop-mediated isothermal amplification with cationic conjugated polymers. The two Chinese medicinal materials (Jin-Yin-Hua and Shan-Yin-Hua) with similar morphology and chemical composition were clearly distinguished by gene SNP genotyping assays. The identification of plant species in Patented Chinese drugs containing Lonicera buds is successfully performed using this detection system. The method is also robust enough to be used in high-throughput screening. This new method is very helpful to identify herbal materials, and is beneficial for detecting safety and quality of botanic products.

  15. Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method

    NASA Astrophysics Data System (ADS)

    Doaei, Marjan; Tavallali, M. Sadegh

    2018-05-01

    The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.

  16. Convenient, Sensitive and High-Throughput Method for Screening Botanic Origin

    NASA Astrophysics Data System (ADS)

    Yuan, Yuan; Jiang, Chao; Liu, Libing; Yu, Shulin; Cui, Zhanhu; Chen, Min; Lin, Shufang; Wang, Shu; Huang, Luqi

    2014-06-01

    In this work, a rapid (within 4-5 h), sensitive and visible new method for assessing botanic origin is developed by combining loop-mediated isothermal amplification with cationic conjugated polymers. The two Chinese medicinal materials (Jin-Yin-Hua and Shan-Yin-Hua) with similar morphology and chemical composition were clearly distinguished by gene SNP genotyping assays. The identification of plant species in Patented Chinese drugs containing Lonicera buds is successfully performed using this detection system. The method is also robust enough to be used in high-throughput screening. This new method is very helpful to identify herbal materials, and is beneficial for detecting safety and quality of botanic products.

  17. Microbial screening for quinolones residues in cow milk by bio-optical method.

    PubMed

    Appicciafuoco, Brunella; Dragone, Roberto; Frazzoli, Chiara; Bolzoni, Giuseppe; Mantovani, Alberto; Ferrini, Anna Maria

    2015-03-15

    The use of antibiotics on lactating cows should be monitored for the possible risk of milk contamination with residues. Accordingly, Maximum Residue Levels (MRLs) are established by the European Commission to guarantee consumers safety. As pointed out by Dec 2002/657/EC, screening is the first step in the strategy for antibiotic residue control, thus playing a key role in the whole control procedure. However, current routine screening methods applied in milk chain still fail to detect residues of quinolones at concentrations of interest. This paper reports the findings of a new bio-optical method for the screening of quinolones residues in bovine milk, based on E. coli ATCC 11303 growth inhibition. The effect of blank and spiked cow milk samples (aliquots equivalents to 0.8%, v/v) is evaluated in Mueller Hinton Broth (MHb) and MHb enriched with MgSO4 2% (MHb-Mg) inoculated with the test strain at the concentration of 10(4)CFU/mL. The presence of quinolones inhibits the cellular growth in MHb, while this effect is neutralized in MHb-Mg allowing both detection and presumptive identification of quinolones. Growth of the test strain is monitored at 37 °C in a Bioscreen C automated system, and Optical Density (OD) at 600 nm is recorded every 10 min after shaking for 10s. Growth curves (OD vs. time) of E. coli ATCC 11303 are assessed in milk samples, with and without quinolones, and their differences in terms of ΔOD (ΔOD600nm=ODMHb-Mg-ODMHb) are calculated. The presence of quinolones is detected by the cellular growth inhibition (OD vs time, none increase in the value OD) and presumptively identified through the increase of the slope of ΔOD600nm curve (ΔOD vs. time), after about 3h of incubation. The detection limit for ciprofloxacin and enrofloxacin is at the level of MRL, for marbofloxacin is at 2-fold the MRL whereas for danofloxacin is at 4-fold the MRL. Although the sensitivity of the method could be further improved and the procedure automated, it is a

  18. An EEG-based machine learning method to screen alcohol use disorder.

    PubMed

    Mumtaz, Wajid; Vuong, Pham Lam; Xia, Likun; Malik, Aamir Saeed; Rashid, Rusdi Bin Abd

    2017-04-01

    Screening alcohol use disorder (AUD) patients has been challenging due to the subjectivity involved in the process. Hence, robust and objective methods are needed to automate the screening of AUD patients. In this paper, a machine learning method is proposed that utilized resting-state electroencephalography (EEG)-derived features as input data to classify the AUD patients and healthy controls and to perform automatic screening of AUD patients. In this context, the EEG data were recorded during 5 min of eyes closed and 5 min of eyes open conditions. For this purpose, 30 AUD patients and 15 aged-matched healthy controls were recruited. After preprocessing the EEG data, EEG features such as inter-hemispheric coherences and spectral power for EEG delta, theta, alpha, beta and gamma bands were computed involving 19 scalp locations. The selection of most discriminant features was performed with a rank-based feature selection method assigning a weight value to each feature according to a criterion, i.e., receiver operating characteristics curve. For example, a feature with large weight was considered more relevant to the target labels than a feature with less weight. Therefore, a reduced set of most discriminant features was identified and further be utilized during classification of AUD patients and healthy controls. As results, the inter-hemispheric coherences between the brain regions were found significantly different between the study groups and provided high classification efficiency ( Accuracy  = 80.8, sensitivity  = 82.5, and specificity  = 80, F - Measure  = 0.78). In addition, the power computed in different EEG bands were found significant and provided an overall classification efficiency as ( Accuracy  = 86.6, sensitivity  = 95, specificity  = 82.5, and F - Measure  = 0.88). Further, the integration of these EEG feature resulted into even higher results ( Accuracy  = 89.3 %, sensitivity  = 88.5 %, specificity  = 91 %, and F

  19. A screening method to distinguish syndromic from sporadic spinal extradural arachnoid cyst.

    PubMed

    Ogura, Yoji; Yabuki, Shoji; Fujibayashi, Shunsuke; Okada, Eijiro; Iwanami, Akio; Watanabe, Kota; Nakamura, Masaya; Matsumoto, Morio; Ishii, Ken; Ikegawa, Shiro

    2018-05-01

    Spinal extradural arachnoid cyst (SEDAC) is a cystic lesion that protrudes into the epidural space from a small dural defect. Early diagnosis of SEDAC is important because its expansion causes neurological damage. Two types of SEDAC, syndromic and sporadic, are present. Syndromic SEDAC is inherited as a part of lymphedema-distichiasis syndrome caused by mutations in the FOXC2 gene; however, it is often mistaken as sporadic because of low penetrance. It is not reasonable to conduct a genetic testing for all SEDAC patients and their family members. The aim of this study is to establish an effective screening method to distinguish syndromic SEDAC from sporadic SEDAC. We performed a retrospective review of medical records and imaging studies of 29 subjects who were diagnosed with SEDAC. Clinical features, family history and magnetic resonance imaging (MRI) were analyzed. Mutations in FOXC2 were examined by Sanger-sequencing of the entire coding region of the genes. SEDAC having a mutation in FOXC2 gene was defined with syndromic SEDAC. Eleven subjects had a heterozygous mutation in FOXC2. They were all familial and hence syndromic SEDAC. Only one proband had known family history of SEDAC at diagnosis. MRI findings and physical examinations, especially eye and leg examinations, were quite useful to screen syndromic SEDAC. Physical examination often showed accompanying lymphedema and distichiasis in syndromic SEDAC. Syndromic SEDAC tended to have multiple cysts out of the thoracolumbar area. We established an effective screening method based on physical examinations and MRI findings. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. Rapid screening method for male DNA by using the loop-mediated isothermal amplification assay.

    PubMed

    Kitamura, Masashi; Kubo, Seiji; Tanaka, Jin; Adachi, Tatsushi

    2017-08-12

    Screening for male-derived biological material from collected samples plays an important role in criminal investigations, especially those involving sexual assaults. We have developed a loop-mediated isothermal amplification (LAMP) assay targeting multi-repeat sequences of the Y chromosome for detecting male DNA. Successful amplification occurred with 0.5 ng of male DNA under isothermal conditions of 61 to 67 °C, but no amplification occurred with up to 10 ng of female DNA. Under the optimized conditions, the LAMP reaction initiated amplification within 10 min and amplified for 20 min. The LAMP reaction was sensitive at levels as low as 1-pg male DNA, and a quantitative LAMP assay could be developed because of the strong correlation between the reaction time and the amount of template DNA in the range of 10 pg to 10 ng. Furthermore, to apply the LAMP assay to on-site screening for male-derived samples, we evaluated a protocol using a simple DNA extraction method and a colorimetric intercalating dye that allows detection of the LAMP reaction by evaluating the change in color of the solution. Using this protocol, samples of male-derived blood and saliva stains were processed in approximately 30 min from DNA extraction to detection. Because our protocol does not require much hands-on time or special equipment, this LAMP assay promises to become a rapid and simple screening method for male-derived samples in forensic investigations.

  1. Chronic kidney disease screening methods and its implication for Malaysia: an in depth review.

    PubMed

    Almualm, Yasmin; Zaman Huri, Hasniza

    2015-01-01

    Chronic Kidney Disease has become a public health problem, imposing heath, social and human cost on societies worldwide. Chronic Kidney Disease remains asymptomatic till late stage when intervention cannot stop the progression of the disease. Therefore, there is an urgent need to detect the disease early. Despite the high prevalence of Chronic Kidney Disease in Malaysia, screening is still lacking behind. This review discusses the strengths and limitations of current screening methods for Chronic Kidney Disease from a Malaysian point of view. Diabetic Kidney Disease was chosen as focal point as Diabetes is the leading cause of Chronic Kidney Disease in Malaysia. Screening for Chronic Kidney Disease in Malaysia includes a urine test for albuminuria and a blood test for serum creatinine. Recent literature indicates that albuminuria is not always present in Diabetic Kidney Disease patients and serum creatinine is only raised after substantial kidney damage has occurred.  Recently, cystatin C was proposed as a potential marker for kidney disease but this has not been studied thoroughly in Malaysia.  Glomerular Filtration Rate is the best method for measuring kidney function and is widely estimated using the Modification of Diet for Renal Disease equation. Another equation, the Chronic Kidney Disease Epidemiology Collaboration Creatinine equation was introduced in 2009. The new equation retained the precision and accuracy of the Modification of Diet for Renal Disease equation at GFR < 60ml/min/1.73m2, showed less bias and improved precision at GFR>60ml/min/1.73m2. In Asian countries, adding an ethnic coefficient to the equation enhanced its performance. In Malaysia, a multi-ethnic Asian population, the Chronic Kidney Disease Epidemiology Collaboration equation should be validated and the Glomerular Filtration Rate should be reported whenever serum creatinine is ordered. Reporting estimated Glomerular Filtration Rate will help diagnose patients who would have been

  2. Chronic Kidney Disease Screening Methods and Its Implication for Malaysia: An in Depth Review

    PubMed Central

    Almualm, Yasmin; Huri, Hasniza Zaman

    2015-01-01

    Chronic Kidney Disease has become a public health problem, imposing heath, social and human cost on societies worldwide. Chronic Kidney Disease remains asymptomatic till late stage when intervention cannot stop the progression of the disease. Therefore, there is an urgent need to detect the disease early. Despite the high prevalence of Chronic Kidney Disease in Malaysia, screening is still lacking behind. This review discusses the strengths and limitations of current screening methods for Chronic Kidney Disease from a Malaysian point of view. Diabetic Kidney Disease was chosen as focal point as Diabetes is the leading cause of Chronic Kidney Disease in Malaysia. Screening for Chronic Kidney Disease in Malaysia includes a urine test for albuminuria and a blood test for serum creatinine. Recent literature indicates that albuminuria is not always present in Diabetic Kidney Disease patients and serum creatinine is only raised after substantial kidney damage has occurred. Recently, cystatin C was proposed as a potential marker for kidney disease but this has not been studied thoroughly in Malaysia. Glomerular Filtration Rate is the best method for measuring kidney function and is widely estimated using the Modification of Diet for Renal Disease equation. Another equation, the Chronic Kidney Disease Epidemiology Collaboration Creatinine equation was introduced in 2009. The new equation retained the precision and accuracy of the Modification of Diet for Renal Disease equation at GFR < 60ml/min/1.73m2, showed less bias and improved precision at GFR>60ml/min/1.73m2. In Asian countries, adding an ethnic coefficient to the equation enhanced its performance. In Malaysia, a multi-ethnic Asian population, the Chronic Kidney Disease Epidemiology Collaboration equation should be validated and the Glomerular Filtration Rate should be reported whenever serum creatinine is ordered. Reporting estimated Glomerular Filtration Rate will help diagnose patients who would have been

  3. In-vivo singlet oxygen threshold doses for PDT.

    PubMed

    Zhu, Timothy C; Kim, Michele M; Liang, Xing; Finlay, Jarod C; Busch, Theresa M

    2015-02-01

    Dosimetry of singlet oxygen ( 1 O 2 ) is of particular interest because it is the major cytotoxic agent causing biological effects for type-II photosensitizers during photodynamic therapy (PDT). An in-vivo model to determine the singlet oxygen threshold dose, [ 1 O 2 ] rx,sh , for PDT was developed. An in-vivo radiation-induced fibrosarcoma (RIF) tumor mouse model was used to correlate the radius of necrosis to the calculation based on explicit PDT dosimetry of light fluence distribution, tissue optical properties, and photosensitizer concentrations. Inputs to the model include five photosensitizer-specific photochemical parameters along with [ 1 O 2 ] rx,sh . Photosensitizer-specific model parameters were determined for benzoporphyrin derivative monoacid ring A (BPD) and compared with two other type-II photosensitizers, Photofrin ® and m-tetrahydroxyphenylchlorin (mTHPC) from the literature. The mean values (standard deviation) of the in-vivo [ 1 O 2 ] rx,sh are approximately 0.56 (0.26) and 0.72 (0.21) mM (or 3.6×10 7 and 4.6×10 7 singlet oxygen per cell to reduce the cell survival to 1/e) for Photofrin ® and BPD, respectively, assuming that the fraction of generated singlet oxygen that interacts with the cell is 1. While the values for the photochemical parameters (ξ, σ, g , β) used for BPD were preliminary and may need further refinement, there is reasonable confidence for the values of the singlet oxygen threshold doses. In comparison, the [ 1 O 2 ] rx,sh value derived from in-vivo mouse study was reported to be 0.4 mM for mTHPC-PDT. However, the singlet oxygen required per cell is reported to be 9×10 8 per cell per 1/ e fractional kill in an in-vitro mTHPC-PDT study on a rat prostate cancer cell line (MLL cells) and is reported to be 7.9 mM for a multicell in-vitro EMT6/Ro spheroid model for mTHPC-PDT. A theoretical analysis is provided to relate the number of in-vitro singlet oxygen required per cell to reach cell killing of 1/ e to in-vivo singlet

  4. Influence relevance voting: an accurate and interpretable virtual high throughput screening method.

    PubMed

    Swamidass, S Joshua; Azencott, Chloé-Agathe; Lin, Ting-Wan; Gramajo, Hugo; Tsai, Shiou-Chuan; Baldi, Pierre

    2009-04-01

    Given activity training data from high-throughput screening (HTS) experiments, virtual high-throughput screening (vHTS) methods aim to predict in silico the activity of untested chemicals. We present a novel method, the Influence Relevance Voter (IRV), specifically tailored for the vHTS task. The IRV is a low-parameter neural network which refines a k-nearest neighbor classifier by nonlinearly combining the influences of a chemical's neighbors in the training set. Influences are decomposed, also nonlinearly, into a relevance component and a vote component. The IRV is benchmarked using the data and rules of two large, open, competitions, and its performance compared to the performance of other participating methods, as well as of an in-house support vector machine (SVM) method. On these benchmark data sets, IRV achieves state-of-the-art results, comparable to the SVM in one case, and significantly better than the SVM in the other, retrieving three times as many actives in the top 1% of its prediction-sorted list. The IRV presents several other important advantages over SVMs and other methods: (1) the output predictions have a probabilistic semantic; (2) the underlying inferences are interpretable; (3) the training time is very short, on the order of minutes even for very large data sets; (4) the risk of overfitting is minimal, due to the small number of free parameters; and (5) additional information can easily be incorporated into the IRV architecture. Combined with its performance, these qualities make the IRV particularly well suited for vHTS.

  5. Multiple search methods for similarity-based virtual screening: analysis of search overlap and precision

    PubMed Central

    2011-01-01

    Background Data fusion methods are widely used in virtual screening, and make the implicit assumption that the more often a molecule is retrieved in multiple similarity searches, the more likely it is to be active. This paper tests the correctness of this assumption. Results Sets of 25 searches using either the same reference structure and 25 different similarity measures (similarity fusion) or 25 different reference structures and the same similarity measure (group fusion) show that large numbers of unique molecules are retrieved by just a single search, but that the numbers of unique molecules decrease very rapidly as more searches are considered. This rapid decrease is accompanied by a rapid increase in the fraction of those retrieved molecules that are active. There is an approximately log-log relationship between the numbers of different molecules retrieved and the number of searches carried out, and a rationale for this power-law behaviour is provided. Conclusions Using multiple searches provides a simple way of increasing the precision of a similarity search, and thus provides a justification for the use of data fusion methods in virtual screening. PMID:21824430

  6. Dioxins in beef samples from Mexico using a low resolution GC/MS screening method.

    PubMed

    Naccha, Lidia; Alanis, Guadalupe; Torres, Anabel; Abad, Esteban; Ábalos, Manuela; Rivera, Josep; Heyer, Lorenzo; Morales, Alberto; Waksman, Noemí

    2010-01-01

    Dioxins in beef were quantified by high resolution gas chromatography coupled to low-resolution mass spectrometry (GC/LRMS). The analyses were performed according to the minimum requirements described in the USEPA 1613 method with some minor modifications. Levels found in the samples were in the range 1.02-8.04 pg WHO-TEQ PCDDs/PCDFs g(-1) fat. For comparison purposes, the maximum level allowed by the European Union is 3 pg WHO-TEQ PCDDs/PCDFs g(-1) fat, and some of these samples surpassed the above-mentioned limit and can be considered as contaminated food. The results confirm that a preliminary screening of dioxins in beef can be performed by GC/LRMS. As far as we know, this is the first report of dioxins in beef in Mexico. After the appropriated tests, the applied methodology could be considered as an alternative screening method for the analysis of PCDD/Fs in other food products.

  7. A choice-based screening method for compulsive drug users in rats.

    PubMed

    Lenoir, Magalie; Augier, Eric; Vouillac, Caroline; Ahmed, Serge H

    2013-07-01

    We describe a protocol for screening compulsive drug users among cocaine self-administering rats, the most frequently used animal model in addiction research. Rats are first trained on several alternating days to self-administer either cocaine (i.v.) or saccharin-sweetened water (by mouth)--a potent, albeit nonessential, nondrug reward. Then rats are allowed to choose between the two rewards over several days until the preference stabilizes. Most rats choose to stop using cocaine and pursue the alternative reward. Only a minority of Wistar strain rats (generally 15%) persist in taking the drug, regardless of the severity of past cocaine use and even when made hungry and offered the possibility to relieve their physiological need. Persistence of cocaine use in the face of a high-stakes choice is a core defining feature of compulsion. This choice-based screening method for compulsive drug users is easy to implement, has several important applications, and compares well with other methods in the field. 2013 by John Wiley & Sons, Inc.

  8. Robust Microplate-Based Methods for Culturing and in Vivo Phenotypic Screening of Chlamydomonas reinhardtii

    PubMed Central

    Haire, Timothy C.; Bell, Cody; Cutshaw, Kirstin; Swiger, Brendan; Winkelmann, Kurt; Palmer, Andrew G.

    2018-01-01

    Chlamydomonas reinhardtii (Cr), a unicellular alga, is routinely utilized to study photosynthetic biochemistry, ciliary motility, and cellular reproduction. Its minimal culture requirements, unicellular morphology, and ease of transformation have made it a popular model system. Despite its relatively slow doubling time, compared with many bacteria, it is an ideal eukaryotic system for microplate-based studies utilizing either, or both, absorbance as well as fluorescence assays. Such microplate assays are powerful tools for researchers in the areas of toxicology, pharmacology, chemical genetics, biotechnology, and more. However, while microplate-based assays are valuable tools for screening biological systems, these methodologies can significantly alter the conditions in which the organisms are cultured and their subsequent physiology or morphology. Herein we describe a novel method for the microplate culture and in vivo phenotypic analysis of growth, viability, and photosynthetic pigments of C. reinhardtii. We evaluated the utility of our assay by screening silver nanoparticles for their effects on growth and viability. These methods are amenable to a wide assortment of studies and present a significant advancement in the methodologies available for research involving this model organism. PMID:29623083

  9. Robust Microplate-Based Methods for Culturing and in Vivo Phenotypic Screening of Chlamydomonas reinhardtii.

    PubMed

    Haire, Timothy C; Bell, Cody; Cutshaw, Kirstin; Swiger, Brendan; Winkelmann, Kurt; Palmer, Andrew G

    2018-01-01

    Chlamydomonas reinhardtii (Cr), a unicellular alga, is routinely utilized to study photosynthetic biochemistry, ciliary motility, and cellular reproduction. Its minimal culture requirements, unicellular morphology, and ease of transformation have made it a popular model system. Despite its relatively slow doubling time, compared with many bacteria, it is an ideal eukaryotic system for microplate-based studies utilizing either, or both, absorbance as well as fluorescence assays. Such microplate assays are powerful tools for researchers in the areas of toxicology, pharmacology, chemical genetics, biotechnology, and more. However, while microplate-based assays are valuable tools for screening biological systems, these methodologies can significantly alter the conditions in which the organisms are cultured and their subsequent physiology or morphology. Herein we describe a novel method for the microplate culture and in vivo phenotypic analysis of growth, viability, and photosynthetic pigments of C. reinhardtii . We evaluated the utility of our assay by screening silver nanoparticles for their effects on growth and viability. These methods are amenable to a wide assortment of studies and present a significant advancement in the methodologies available for research involving this model organism.

  10. Screening method for selecting semiconductor substrates having defects below a predetermined level in an oxide layer

    DOEpatents

    Warren, W.L.; Vanheusden, K.J.R.; Schwank, J.R.; Fleetwood, D.M.; Shaneyfelt, M.R.; Winokur, P.S.; Devine, R.A.B.

    1998-07-28

    A method is disclosed for screening or qualifying semiconductor substrates for integrated circuit fabrication. The method comprises the steps of annealing at least one semiconductor substrate at a first temperature in a defect-activating ambient (e.g. hydrogen, forming gas, or ammonia) for sufficient time for activating any defects within on oxide layer of the substrate; measuring a defect-revealing electrical characteristic of at least a portion of the oxide layer for determining a quantity of activated defects therein; and selecting substrates for which the quantity of activated defects is below a predetermined level. The defect-revealing electrical characteristic may be a capacitance-versus voltage (C-V) characteristic or a current-versus-voltage (I-V) characteristic that is dependent on an electrical charge in the oxide layer generated by the activated defects. Embodiments of the present invention may be applied for screening any type of semiconductor substrate or wafer having an oxide layer formed thereon or therein. This includes silicon-on-insulator substrates formed by a separation by the implantation of oxygen (SIMOX) process or the bond and etch back silicon-on-insulator (BESOI) process, as well as silicon substrates having a thermal oxide layer or a deposited oxide layer. 5 figs.

  11. Screening method for selecting semiconductor substrates having defects below a predetermined level in an oxide layer

    DOEpatents

    Warren, William L.; Vanheusden, Karel J. R.; Schwank, James R.; Fleetwood, Daniel M.; Shaneyfelt, Marty R.; Winokur, Peter S.; Devine, Roderick A. B.

    1998-01-01

    A method for screening or qualifying semiconductor substrates for integrated circuit fabrication. The method comprises the steps of annealing at least one semiconductor substrate at a first temperature in a defect-activating ambient (e.g. hydrogen, forming gas, or ammonia) for sufficient time for activating any defects within on oxide layer of the substrate; measuring a defect-revealing electrical characteristic of at least a portion of the oxide layer for determining a quantity of activated defects therein; and selecting substrates for which the quantity of activated defects is below a predetermined level. The defect-revealing electrical characteristic may be a capacitance-versus-voltage (C-V) characteristic or a current-versus-voltage (I-V) characteristic that is dependent on an electrical charge in the oxide layer generated by the activated defects. Embodiments of the present invention may be applied for screening any type of semiconductor substrate or wafer having an oxide layer formed thereon or therein. This includes silicon-on-insulator substrates formed by a separation by the implantation of oxygen (SIMOX) process or the bond and etch back silicon-on-insulator (BESOI) process, as well as silicon substrates having a thermal oxide layer or a deposited oxide layer.

  12. "Inject-mix-react-separate-and-quantitate" (IMReSQ) method for screening enzyme inhibitors.

    PubMed

    Wong, Edmund; Okhonin, Victor; Berezovski, Maxim V; Nozaki, Tomoyoshi; Waldmann, Herbert; Alexandrov, Kirill; Krylov, Sergey N

    2008-09-10

    Many regulatory enzymes are considered attractive therapeutic targets, and their inhibitors are potential drug candidates. Screening combinatorial libraries for enzyme inhibitors is pivotal to identifying hit compounds for the development of drugs targeting regulatory enzymes. Here, we introduce the first inhibitor screening method that consumes only nanoliters of the reactant solutions and is applicable to regulatory enzymes. The method is termed inject-mix-react-separate-and-quantitate (IMReSQ) and includes five steps. First, nanoliter volumes of substrate, candidate inhibitor, and enzyme solutions are injected by pressure into a capillary as separate plugs. Second, the plugs are mixed inside this capillary microreactor by transverse diffusion of laminar flow profiles. Third, the reaction mixture is incubated to form the enzymatic product. Fourth, the product is separated from the substrate inside the capillary by electrophoresis. Fifth, the amounts of the product and substrate are quantitated. In this proof-of-principle work, we applied IMReSQ to study inhibition of recently cloned protein farnesyltransferase from parasite Entamoeba histolytica. This enzyme is a potential therapeutic target for antiparasitic drugs. We identified three previously unknown inhibitors of this enzyme and proved that IMReSQ could be used for quantitatively ranking the potencies of inhibitors.

  13. Pharmacy diabetes care program: analysis of two screening methods for undiagnosed type 2 diabetes in Australian community pharmacy.

    PubMed

    Krass, I; Mitchell, B; Clarke, P; Brillant, M; Dienaar, R; Hughes, J; Lau, P; Peterson, G; Stewart, K; Taylor, S; Wilkinson, J; Armour, C

    2007-03-01

    To compare the efficacy and cost-effectiveness of two methods of screening for undiagnosed type 2 diabetes in Australian community pharmacy. A random sample of 30 pharmacies were allocated into two groups: (i) tick test only (TTO); or (ii) sequential screening (SS) method. Both methods used the same initial risk assessment for type 2 diabetes. Subjects with one or more risk factors in the TTO group were offered a referral to their general practitioner (GP). Under the SS method, patients with risk factors were offered a capillary blood glucose test and those identified as being at risk referred to a GP. The effectiveness and cost-effectiveness of these approaches was assessed. A total of 1286 people were screened over a period of 3 months. The rate of diagnosis of diabetes was significantly higher for SS compared with the TTO method (1.7% versus 0.2%; p=0.008). The SS method resulted in fewer referrals to the GP and a higher uptake of referrals than the TTO method and so was the more cost-effective screening method. SS is the superior method from a cost and efficacy perspective. It should be considered as the preferred option for screening by community based pharmacists in Australia.

  14. SPLICEFINDER – A Fast and Easy Screening Method for Active Protein Trans-Splicing Positions

    PubMed Central

    Eppmann, Simone; Busche, Alena; Dikovskaya, Dina; Dötsch, Volker; Mootz, Henning D.

    2013-01-01

    Split intein enabled protein trans-splicing (PTS) is a powerful method for the ligation of two protein fragments, thereby paving the way for various protein modification or protein function control applications. PTS activity is strongly influenced by the amino acids directly flanking the splice junctions. However, to date no reliable prediction can be made whether or not a split intein is active in a particular foreign extein context. Here we describe SPLICEFINDER, a PCR-based method, allowing fast and easy screening for active split intein insertions in any target protein. Furthermore we demonstrate the applicability of SPLICEFINDER for segmental isotopic labeling as well as for the generation of multi-domain and enzymatically active proteins. PMID:24023792

  15. Research on atmospheric transmission distortion of Gauss laser using multiple phase screen method

    NASA Astrophysics Data System (ADS)

    Zhang, Yizhuo; Wang, Qiushi; Gu, Haidong

    2018-02-01

    The laser beam is attenuated, broadened, defocused and may even be deflected from its initial propagation direction as it propagates through the atmosphere. It leads to the decrease of the laser intensity of the receiving surface. Gauss beam is the fundamental components of all possible laser waveforms. Therefore, research on the transmission of the Gauss laser has far-reaching consequences in optical communication, weaponry, target designation, ranging, remote sensing and other applications that require transmission of laser beams through the atmosphere. In this paper, we propose a laboratory simulation method using multi-phase screen to calculate the effects of atmospheric turbulence. Theoretical analysis of Gauss laser transmission in the atmosphere is given. By calculating the propagation of the Gauss beam TEM00, the far field intensity and phase distribution is shown. By the given method, the optical setup is presented and used for optimizing the adaptive optics algorithm.

  16. A simple screening method using ion chromatography for the diagnosis of cerebral creatine deficiency syndromes.

    PubMed

    Wada, Takahito; Shimbo, Hiroko; Osaka, Hitoshi

    2012-08-01

    Cerebral creatine deficiency syndromes (CCDS) are caused by genetic defects in L-arginine:glycine amidinotransferase, guanidinoacetate methyltransferase or creatine transporter 1. CCDS are characterized by abnormal concentrations of urinary creatine (CR), guanidinoacetic acid (GA), or creatinine (CN). In this study, we describe a simple HPLC method to determine the concentrations of CR, GA, and CN using a weak-acid ion chromatography column with a UV detector without any derivatization. CR, GA, and CN were separated clearly with the retention times (mean ± SD, n = 3) of 5.54 ± 0.0035 min for CR, 6.41 ± 0.0079 min for GA, and 13.53 ± 0.046 min for CN. This new method should provide a simple screening test for the diagnosis of CCDS.

  17. Implementing a method of screening one-well hydraulic barrier design alternatives.

    PubMed

    Rubin, Hillel; Shoemaker, Christine A; Köngeter, Jürgen

    2009-01-01

    This article provides details of applying the method developed by the authors (Rubin et al. 2008b) for screening one-well hydraulic barrier design alternatives. The present article with its supporting information (manual and electronic spreadsheets with a case history example) provides the reader complete details and examples of solving the set of nonlinear equations developed by Rubin et al. (2008b). It allows proper use of the analytical solutions and also depicting the various charts given by Rubin et al. (2008b). The final outputs of the calculations are the required position and the discharge of the pumping well. If the contaminant source is nonaqueous phase liquid (NAPL) entrapped within the aquifer, then the method provides an estimate of the aquifer remediation progress (which is a by-product) due to operating the hydraulic barrier.

  18. Experimental design and statistical methods for improved hit detection in high-throughput screening.

    PubMed

    Malo, Nathalie; Hanley, James A; Carlile, Graeme; Liu, Jing; Pelletier, Jerry; Thomas, David; Nadon, Robert

    2010-09-01

    Identification of active compounds in high-throughput screening (HTS) contexts can be substantially improved by applying classical experimental design and statistical inference principles to all phases of HTS studies. The authors present both experimental and simulated data to illustrate how true-positive rates can be maximized without increasing false-positive rates by the following analytical process. First, the use of robust data preprocessing methods reduces unwanted variation by removing row, column, and plate biases. Second, replicate measurements allow estimation of the magnitude of the remaining random error and the use of formal statistical models to benchmark putative hits relative to what is expected by chance. Receiver Operating Characteristic (ROC) analyses revealed superior power for data preprocessed by a trimmed-mean polish method combined with the RVM t-test, particularly for small- to moderate-sized biological hits.

  19. Characterization and in-vivo evaluation of potential probiotics of the bacterial flora within the water column of a healthy shrimp larviculture system

    NASA Astrophysics Data System (ADS)

    Xue, Ming; Liang, Huafang; He, Yaoyao; Wen, Chongqing

    2016-05-01

    A thorough understanding of the normal bacterial flora associated with shrimp larviculture systems contributes to probiotic screening and disease control. The bacterial community of the water column over a commercial Litopenaeus vannamei larval rearing run was characterized with both culture-dependent and culture-independent methods. A total of 27 phylotypes at the species level were isolated and identified based on 16S rDNA sequence analysis. Denaturing gradient gel electrophoresis (DGGE) analysis of the V3-V5 region of 16S rRNA genes showed a dynamic bacterial community with major changes occurred from stages zoea to mysis during the rearing run. The sequences retrieved were affiliated to four phyla, Proteobacteria, Actinobacteria, Bacteroidetes, and Firmicutes, with the family Rhodobacteraceae being the most frequently recovered one. Subsequently, 13 representative strains conferred higher larval survival than the control when evaluated in the in-vivo experiments; in particular, three candidates, assigned to Phaeobacter sp., Arthrobacter sp., and Microbacterium sp., significantly improved larval survival ( P < 0.05). Therefore, the healthy shrimp larviculture system harbored a diverse and favorable bacterial flora, which contribute to larval development and are of great importance in exploiting novel probiotics.

  20. Evaluation of Dried Urine Spot Method to Screen Cotinine among Tobacco Dependents: An Exploratory Study.

    PubMed

    Jain, Raka; Quraishi, Rizwana; Verma, Arpita

    2017-01-01

    Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.

  1. An efficient and rapid transgenic pollen screening and detection method using flow cytometry.

    PubMed

    Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal

    2011-01-01

    Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.

  2. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia.

    PubMed

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D; Smirnakis, Stelios; Aslanides, Ioannis M

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel

  3. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia

    PubMed Central

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D.; Smirnakis, Stelios; Aslanides, Ioannis M.

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel

  4. An Improved Nonradioactive Screening Method Identifies Genistein and Xanthohumol as Potent Inhibitors of Iodothyronine Deiodinases.

    PubMed

    Renko, Kostja; Schäche, Sonja; Hoefig, Carolin S; Welsink, Tim; Schwiebert, Christian; Braun, Doreen; Becker, Niels-Peter; Köhrle, Josef; Schomburg, Lutz

    2015-08-01

    enzymes were monitored with various nonradioactive substrates and confirmed by liquid chromatography-tandem mass spectrometry. The contrast agent and known DIO inhibitor iopanoic acid was characterized as readily accepted substrate by DIO2 and Dio3. In a screening approach using established endocrine disrupting compounds, the natural food ingredient genistein was identified as a further DIO1-specific inhibitor, while xanthohumol turned out to potently block the activity of all three isoenzymes. A rapid nonradioactive screening method based on the Sandell-Kolthoff reaction is suitable for identification of environmental, nutritive and pharmacological compounds modulating activities of human deiodinase enzymes.

  5. An effective method to screen sodium-based layered materials for sodium ion batteries

    NASA Astrophysics Data System (ADS)

    Zhang, Xu; Zhang, Zihe; Yao, Sai; Chen, An; Zhao, Xudong; Zhou, Zhen

    2018-03-01

    Due to the high cost and insufficient resource of lithium, sodium-ion batteries are widely investigated for large-scale applications. Typically, insertion-type materials possess better cyclic stability than alloy-type and conversion-type ones. Therefore, in this work, we proposed a facile and effective method to screen sodium-based layered materials based on Materials Project database as potential candidate insertion-type materials for sodium ion batteries. The obtained Na-based layered materials contains 38 kinds of space group, which reveals that the credibility of our screening approach would not be affected by the space group. Then, some important indexes of the representative materials, including the average voltage, volume change and sodium ion mobility, were further studied by means of density functional theory computations. Some materials with extremely low volume changes and Na diffusion barriers are promising candidates for sodium ion batteries. We believe that our classification algorithm could also be used to search for other alkali and multivalent ion-based layered materials, to accelerate the development of battery materials.

  6. OSO paradigm--A rapid behavioral screening method for acute psychosocial stress reactivity in mice.

    PubMed

    Brzózka, M M; Unterbarnscheidt, T; Schwab, M H; Rossner, M J

    2016-02-09

    Chronic psychosocial stress is an important environmental risk factor for the development of psychiatric diseases. However, studying the impact of chronic psychosocial stress in mice is time consuming and thus not optimally suited to 'screen' increasing numbers of genetically manipulated mouse models for psychiatric endophenotypes. Moreover, many studies focus on restraint stress, a strong physical stressor with limited relevance for psychiatric disorders. Here, we describe a simple and a rapid method based on the resident-intruder paradigm to examine acute effects of mild psychosocial stress in mice. The OSO paradigm (open field--social defeat--open field) compares behavioral consequences on locomotor activity, anxiety and curiosity before and after exposure to acute social defeat stress. We first evaluated OSO in male C57Bl/6 wildtype mice where a single episode of social defeat reduced locomotor activity, increased anxiety and diminished exploratory behavior. Subsequently, we applied the OSO paradigm to mouse models of two schizophrenia (SZ) risk genes. Transgenic mice with neuronal overexpression of Neuregulin-1 (Nrg1) type III showed increased risk-taking behavior after acute stress exposure suggesting that NRG1 dysfunction is associated with altered affective behavior. In contrast, Tcf4 transgenic mice displayed a normal stress response which is in line with the postulated predominant contribution of TCF4 to cognitive deficits of SZ. In conclusion, the OSO paradigm allows for rapid screening of selected psychosocial stress-induced behavioral endophenotypes in mouse models of psychiatric diseases. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  7. High-throughput behavioral screening method for detecting auditory response defects in zebrafish.

    PubMed

    Bang, Pascal I; Yelick, Pamela C; Malicki, Jarema J; Sewell, William F

    2002-08-30

    We have developed an automated, high-throughput behavioral screening method for detecting hearing defects in zebrafish. Our assay monitors a rapid escape reflex in response to a loud sound. With this approach, 36 adult zebrafish, restrained in visually isolated compartments, can be simultaneously assessed for responsiveness to near-field 400 Hz sinusoidal tone bursts. Automated, objective determinations of responses are achieved with a computer program that obtains images at precise times relative to the acoustic stimulus. Images taken with a CCD video camera before and after stimulus presentation are subtracted to reveal a response to the sound. Up to 108 fish can be screened per hour. Over 6500 fish were tested to validate the reliability of the assay. We found that 1% of these animals displayed hearing deficits. The phenotypes of non-responders were further assessed with radiological analysis for defects in the gross morphology of the auditory system. Nearly all of those showed abnormalities in conductive elements of the auditory system: the swim bladder or Weberian ossicles. Copyright 2002 Elsevier Science B.V.

  8. A robust screening method for dietary agents that activate tumour-suppressor microRNAs

    PubMed Central

    Hagiwara, Keitaro; Gailhouste, Luc; Yasukawa, Ken; Kosaka, Nobuyoshi; Ochiya, Takahiro

    2015-01-01

    Certain dietary agents, such as natural products, have been reported to show anti-cancer effects. However, the underlying mechanisms of these substances in human cancer remain unclear. We recently found that resveratrol exerts an anti-cancer effect by upregulating tumour-suppressor microRNAs (miRNAs). In the current study, we aimed to identify new dietary products that have the ability to activate tumour-suppressor miRNAs and that therefore may serve as novel tools for the prevention and treatment of human cancers. We describe the generation and use of an original screening system based on a luciferase-based reporter vector for monitoring miR-200c tumour-suppressor activity. By screening a library containing 139 natural substances, three natural compounds — enoxolone, magnolol and palmatine chloride — were identified as being capable of inducing miR-200c expression in breast cancer cells at 10 μM. Moreover, these molecules suppressed the invasiveness of breast cancer cells in vitro. Next, we identified a molecular pathway by which the increased expression of miR-200c induced by natural substances led to ZEB1 inhibition and E-cadherin induction. These results indicate that our method is a valuable tool for a fast identification of natural molecules that exhibit tumour-suppressor activity in human cancer through miRNA activation. PMID:26423775

  9. Benchmarking methods and data sets for ligand enrichment assessment in virtual screening.

    PubMed

    Xia, Jie; Tilahun, Ermias Lemma; Reid, Terry-Elinor; Zhang, Liangren; Wang, Xiang Simon

    2015-01-01

    Retrospective small-scale virtual screening (VS) based on benchmarking data sets has been widely used to estimate ligand enrichments of VS approaches in the prospective (i.e. real-world) efforts. However, the intrinsic differences of benchmarking sets to the real screening chemical libraries can cause biased assessment. Herein, we summarize the history of benchmarking methods as well as data sets and highlight three main types of biases found in benchmarking sets, i.e. "analogue bias", "artificial enrichment" and "false negative". In addition, we introduce our recent algorithm to build maximum-unbiased benchmarking sets applicable to both ligand-based and structure-based VS approaches, and its implementations to three important human histone deacetylases (HDACs) isoforms, i.e. HDAC1, HDAC6 and HDAC8. The leave-one-out cross-validation (LOO CV) demonstrates that the benchmarking sets built by our algorithm are maximum-unbiased as measured by property matching, ROC curves and AUCs. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Benchmarking Methods and Data Sets for Ligand Enrichment Assessment in Virtual Screening

    PubMed Central

    Xia, Jie; Tilahun, Ermias Lemma; Reid, Terry-Elinor; Zhang, Liangren; Wang, Xiang Simon

    2014-01-01

    Retrospective small-scale virtual screening (VS) based on benchmarking data sets has been widely used to estimate ligand enrichments of VS approaches in the prospective (i.e. real-world) efforts. However, the intrinsic differences of benchmarking sets to the real screening chemical libraries can cause biased assessment. Herein, we summarize the history of benchmarking methods as well as data sets and highlight three main types of biases found in benchmarking sets, i.e. “analogue bias”, “artificial enrichment” and “false negative”. In addition, we introduced our recent algorithm to build maximum-unbiased benchmarking sets applicable to both ligand-based and structure-based VS approaches, and its implementations to three important human histone deacetylase (HDAC) isoforms, i.e. HDAC1, HDAC6 and HDAC8. The Leave-One-Out Cross-Validation (LOO CV) demonstrates that the benchmarking sets built by our algorithm are maximum-unbiased in terms of property matching, ROC curves and AUCs. PMID:25481478

  11. An end-point method based on graphene oxide for RNase H analysis and inhibitors screening.

    PubMed

    Zhao, Chuan; Fan, Jialong; Peng, Lan; Zhao, Lijian; Tong, Chunyi; Wang, Wei; Liu, Bin

    2017-04-15

    As a highly conserved damage repair protein, RNase H can hydrolysis DNA-RNA heteroduplex endonucleolytically and cleave RNA-DNA junctions as well. In this study, we have developed an accurate and sensitive RNase H assay based on fluorophore-labeled chimeric substrate hydrolysis and the differential affinity of graphene oxide on RNA strand with different length. This end-point measurement method can detect RNase H in a range of 0.01 to 1 units /mL with a detection limit of 5.0×10 -3 units/ mL under optimal conditions. We demonstrate the utility of the assay by screening antibiotics, resulting in the identification of gentamycin, streptomycin and kanamycin as inhibitors with IC 50 of 60±5µM, 70±8µM and 300±20µM, respectively. Furthermore, the assay was reliably used to detect RNase H in complicated biosamples and found that RNase H activity in tumor cells was inhibited by gentamycin and streptomycin sulfate in a concentration-dependent manner. The average level of RNase H in serums of HBV infection group was similar to that of control group. In summary, the assay provides an alternative tool for biochemical analysis for this enzyme and indicates the feasibility of high throughput screening inhibitors of RNase H in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Screening and confirmatory methods for the analysis of macrocyclic lactone mycotoxins by CE with amperometric detection.

    PubMed

    Arribas, Alberto Sánchez; Bermejo, Esperanza; Zapardiel, Antonio; Téllez, Helena; Rodríguez-Flores, Juana; Zougagh, Mohammed; Ríos, Angel; Chicharro, Manuel

    2009-02-01

    A simple analytical scheme for the screening and quantification of zearalenone and its metabolites, alpha-zearalenol and beta-zearalenol, is reported. Extracts from maize flour samples were collected by supercritical fluid extraction and afterwards, they were analyzed by CE with amperometric detection. This scheme allowed a rapid and reliable identification of contaminated flour samples according to the reference value established for zearalenone by directive 2005/38/EC (200 microg/kg). The sample screening method was carried out by CZE using 25 mM borate separation buffer at pH 9.2 and 25.0 kV as separation voltage, monitoring the amperometric signal at +700 mV with a carbon paste electrode. In this way, total amount of mycotoxins was determined and samples were processed in 4 min with a detection limit of 12 microg/L, enough to discriminate between positive (more than 200 microg/L total mycotoxins) and negative samples (less than 200 microg/L total mycotoxins). Positive samples were then subjected to CZE separation and quantification of each analyte was done with 50 mM borate running buffer modified with 30% methanol at pH 9.7 and 17.5 kV as separation voltage. Under these conditions, separation was achieved in 15 min with detection limits from 20 to 35 microg/L for each analyte.

  13. Simplified methods for screening cowpea cultivars for manganese leaf-tissue tolerance. [Vigna unguiculata

    SciTech Connect

    Wissemeier, A.H.; Horst, W.J.

    In cowpea (Vigna unguiculata (L.) Walp.) dark brown speckles on old leaves are typical symptoms of Mn toxicity and indicate Mn sensitivity of leaf tissue. Induction and subsequent quantification of brown Mn speckles in leaf tissues were used to screen cowpea cultivars for Mn leaf-tissue tolerance using three different techniques: (i) leaf cuttings cultured for 22 days in solution culture with 20 {mu}M MnSO{sub 4}, (ii) leaf rings mounted on leaves of intact plants and filled with 500 {mu}M MnSO{sub 4} for 5 days, and (iii) leaf disks floated for 3 days on 500 {mu}M MnSO{sub 4}. Density of brownmore » speckles differed considerably among the six cultivars tested, and was not related to the Mn concentrations of the leaf tissues. There were close relationships between genotypic Mn-toxicity symptom expression and depression of dry matter production of the cultivars at high Mn supply in a long-term sand culture experiment. The floating leaf-disk method is particularly suited for screening large numbers of cowpea cultivars for Mn leaf-tissue tolerance because it requires only 3 days. The ranking of the cultivars for Mn tolerance was highly correlated to Mn tolerance of intact plants.« less

  14. Broth Microdilution In Vitro Screening: An Easy and Fast Method to Detect New Antifungal Compounds.

    PubMed

    de-Souza-Silva, Calliandra Maria; Guilhelmelli, Fernanda; Zamith-Miranda, Daniel; de Oliveira, Marco Antônio; Nosanchuk, Joshua Daniel; Silva-Pereira, Ildinete; Albuquerque, Patrícia

    2018-02-14

    Fungal infections have become an important medical condition in the last decades, but the number of available antifungal drugs is limited. In this scenario, the search for new antifungal drugs is necessary. The protocol reported here details a method to screen peptides for their antifungal properties. It is based on the broth microdilution susceptibility test from the Clinical and Laboratory Standards Institute (CLSI) M27-A3 guidelines with modifications to suit the research of antimicrobial peptides as potential new antifungals. This protocol describes a functional assay to evaluate the activity of antifungal compounds and may be easily modified to suit any particular class of molecules under investigation. Since the assays are performed in 96-well plates using small volumes, a large-scale screening can be completed in a short amount of time, especially if carried out in an automation setting. This procedure illustrates how a standardized and adjustable clinical protocol can help the bench-work pursuit of new molecules to improve the therapy of fungal diseases.

  15. Adaptive Chroma Subsampling-binding and Luma-guided Chroma Reconstruction Method for Screen Content Images.

    PubMed

    Chung, Kuo-Liang; Huang, Chi-Chao; Hsu, Tsu-Chun

    2017-09-04

    In this paper, we propose a novel adaptive chroma subsampling-binding and luma-guided (ASBLG) chroma reconstruction method for screen content images (SCIs). After receiving the decoded luma and subsampled chroma image from the decoder, a fast winner-first voting strategy is proposed to identify the used chroma subsampling scheme prior to compression. Then, the decoded luma image is subsampled as the identified subsampling scheme was performed on the chroma image such that we are able to conclude an accurate correlation between the subsampled decoded luma image and the decoded subsampled chroma image. Accordingly, an adaptive sliding window-based and luma-guided chroma reconstruction method is proposed. The related computational complexity analysis is also provided. We take two quality metrics, the color peak signal-to-noise ratio (CPSNR) of the reconstructed chroma images and SCIs and the gradient-based structure similarity index (CGSS) of the reconstructed SCIs to evaluate the quality performance. Let the proposed chroma reconstruction method be denoted as 'ASBLG'. Based on 26 typical test SCIs and 6 JCT-VC test screen content video sequences (SCVs), several experiments show that on average, the CPSNR gains of all the reconstructed UV images by 4:2:0(A)-ASBLG, SCIs by 4:2:0(MPEG-B)-ASBLG, and SCVs by 4:2:0(A)-ASBLG are 2.1 dB, 1.87 dB, and 1.87 dB, respectively, when compared with that of the other combinations. Specifically, in terms of CPSNR and CGSS, CSBILINEAR-ASBLG for the test SCIs and CSBICUBIC-ASBLG for the test SCVs outperform the existing state-of-the-art comparative combinations, where CSBILINEAR and CSBICUBIC denote the luma-aware based chroma subsampling schemes by Wang et al.

  16. A cost-effective screening method for pesticide residue analysis in fruits, vegetables, and cereal grains.

    PubMed

    Ambrus, A; Füzesi, I; Susán, M; Dobi, D; Lantos, J; Zakar, F; Korsós, I; Oláh, J; Beke, B B; Katavics, L

    2005-01-01

    This paper reports the results of studies performed to investigate the potential of applying thin layer chromatography (TLC) detection in combination with selected extraction and cleanup methods, for providing an alternative cost-effective analytical procedure for screening and confirmation of pesticide residues in plant commodities. The extraction was carried out with ethyl acetate and an on-line extraction method applying an acetone-dichloromethane mixture. The extracts were cleaned up with SX-3 gel, an adsorbent mixture of active carbon, magnesia, and diatomaceous earth, and on silica micro cartridges. The Rf values of 118 pesticides were tested in eleven elution systems with UV, and eight biotest methods and chemical detection reagents. Cabbage, green peas, orange, and tomatoes were selected as representative sample matrices for fruits and vegetables, while maize, rice, and wheat represented cereal grains. As an internal quality control measure, marker compounds were applied on each plate to verify the proper elution and detection conditions. The Rf values varied in the different elution systems. The best separation (widest Rf range) was achieved with silica gel (SG)--ethyl acetate (0.05-0.7), SG--benzene, (0.02-0.7) and reverse phase RP-18 F-254S layer with acetone: methanol: water/30:30:30 (v/v) (0.1-0.8). The relative standard deviation of Rf values (CV(Rf)) within laboratory reproducibility was generally less than 20%, except below 0.2 Rf, where the CVRf rapidly increased with decreasing Rf values. The fungi spore inhibition, chloroplast inhibition, and enzyme inhibition were found most suitable for detection of pesticides primarily for confirming their identity or screening for known substances. Their use for determination of pesticide residues in samples of unknown origin is not recommended.

  17. Screening for depression in epilepsy clinics. A comparison of conventional and visual-analog methods.

    PubMed

    Rampling, Jeremy; Mitchell, Alex J; Von Oertzen, Tim; Docker, James; Jackson, Jemima; Cock, Hannah; Agrawal, Niruj

    2012-10-01

    Depression is an important but underdiagnosed complication of epilepsy. This study compares potentially suitable screening tools head-to-head. We enrolled 266 attendees with a confirmed diagnosis of epilepsy at a specialized neurologic epilepsy service in London and compared verbal self-report and visual analog (VAS) screening methods for depression. These included two generic depression scales (Hospital Anxiety and Depression Scale [HADS], Beck Depression Inventory II [BDI-II]), one epilepsy specific scale (Neurological Disorders Depression Inventory for Epilepsy [NDDI-E]) and one new visual-analog scale (Emotional Thermometers [ET]). We used Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for major depression and International Classification of Diseases, Tenth Revision (ICD-10) criteria for depressive episode as the reference standard. Against ICD-10-defined depression the most accurate scales by receiver operating characteristic (ROC) curve area were HADS Total (HADS-T, 0.924), BDI-II (0.898) and NDDI-E (0.897). New visual-analog methods had similar accuracy measured either in combination or individually. Although no test performed well in a case-finding role, several performed well as a rule-out initial step, owing to high negative predictive value and specificity. In this role, the optimal performing conventional tools were the HADS depression subsscale (HADS-D) and the NDDI-E and the optimal single VAS were the depression thermometer (DepT) and the distress thermometer (DT). Against DSM-IV- defined major depression, results were similar with optimal performance by the HADS-T, BDI-II, and NDDI-E, but here the anxiety thermometer (AnxT) as well as DepT and DT also offered good performance. Given that no test performed well in a case-finding role, we suggest that these tests are used as an initial first step to rule out patients who are unlikely to have depression. We suggest that the six-item NDDI-E or seven-item HADS

  18. [Methicillin resistance detection in Staphylococcus aureus: comparison between conventional methods and MRSA-Screen latex agglutination technique].

    PubMed

    Soloaga, R; Corso, A; Gagetti, P; Faccone, D; Galas, M

    2004-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen that has emerged over the last four decades, causing both nosocomial and community-acquired infections. Rapid and accurate detection of methicillin resistance in S. aureus is important for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of MRSA strains. We evaluated the efficiency of conventional methods for detection of methicillin resistance such as the disk diffusion, agar dilution, oxacillin agar screen test, and the latex agglutination test MRSA-Screen latex, in 100 isolates of S. aureus, 79 mecA positive and 21 mecA negative. The MRSA-Screen latex (Denka Seiken, Niigata, Japón), is a latex agglutination method that detects the presence of PLP-2a, product of mecA gene in S. aureus. The PCR of the mecA gene was used as the "gold standard" for the evaluation of the different methods tested. The percentages of sensitivity and specificity were as follows: disk difusión 97 and 100%, agar dilution 97 and 95%, oxacillin agar screen test 100 and 100%, and MRSA-Screen latex, 100 and 100 %. All methods presented high sensitivity and specificity, but MRSA-Screen latex had the advantage of giving a reliable result, equivalent to PCR, in only 15 minutes.

  19. Real time monitoring in-vivo micro-environment through the wound heal mechanism

    NASA Astrophysics Data System (ADS)

    Yan, Jack

    2013-02-01

    One of the In-vivo system's challenge is real time display the sensing information. Usually Ultrasound, CT, MRI, PET are used to get the internal information, this thesis proposed another approach to address the display challenge. Special nano-particles are in-taken or injected to living subject (usually into blood circulation) to sense and collect psychological information when the active particles pass through the tissues of interest. Using the wound healing mechanism, these activated particles (Information collected) can be drifted out to the wound area and adhibited close to the skin, then skin can show different color if the activated particles are concentrated enough in the specific area to create a skin screen. The skin screen can display the blood status, internal organ's temperature, pressure depending the nano-particles' function and their pathway. This approach can also be used to display in-body video if the particles are sensitive and selective enough. In the future, the skin screen can be bio-computer's monitor. The wound healing in an animal model normally divides in four phase: Hemostasis, Inflammation, Proliferation and Maturation. Hemostasis phase is to form a stable clot sealing the damaged vessel. Inflammation phase causes the blood vessels to become leaky releasing plasma and PMN's (polymorphonucleocytes) into the surrounding tissue and provide the first line of defense against infection. Proliferation phase involves replacement of dermal tissues and sometimes subdermal tissues in deeper wounds as well as contraction of the wound. Maturation phase remodels the dermal tissues mainly by fibroblast to produce greater tensile strength. The skin screen wound will be carefully controlled to be triggered at dermis layer.

  20. A Mixed Methods Review of Education and Patient Navigation Interventions to Increase Breast and Cervical Cancer Screening for Rural Women.

    PubMed

    Falk, Derek

    2018-01-01

    Reviews have assessed studies of breast and cervical cancer screening access and utilization for rural women, but none analyze interventions to increase screening rates. A mixed methods literature search identified studies of breast and/or cervical cancer prevention education and patient navigation interventions for rural women. Rural areas need greater implementation and evaluation of screening interventions as these services address the challenges of delivering patient-centered cancer care to un-/underserved communities. The lack of intervention studies on breast and cervical cancer education and patient navigation programs compared to urban studies highlights the need for validation of these programs among diverse, rural populations.

  1. Comparison of Adsorbed Mercury Screening Method With Cold-Vapor Atomic Absorption Spectrophotometry for Determination of Mercury in Soil

    NASA Technical Reports Server (NTRS)

    Easterling, Donald F.; Hovanitz, Edward S.; Street, Kenneth W.

    2000-01-01

    A field screening method for the determination of elemental mercury in environmental soil samples involves the thermal desorption of the mercury from the sample onto gold and then the thermal desorption from the gold to a gold-film mercury vapor analyzer. This field screening method contains a large number of conditions that could be optimized for the various types of soils encountered. In this study, the conditions were optimized for the determination of mercury in silty clay materials, and the results were comparable to the cold-vapor atomic absorption spectrophotometric method of determination. This paper discusses the benefits and disadvantages of employing the field screening method and provides the sequence of conditions that must be optimized to employ this method of determination on other soil types.

  2. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    SciTech Connect

    Avonto, Cristina; Chittiboyina, Amar G.; Rua, Diego

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles aftermore » incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction

  3. A Novel Yeast Surface Display Method for Large-Scale Screen Inhibitors of Sortase A.

    PubMed

    Wu, Lin; Li, Huijun; Tang, Tianle

    2017-01-24

    Fluorescence resonance energy transfer substrates of sortase A are too expensive to be used to roughly screen high-throughput sortase A inhibitors. This makes therapeutic strategies difficult to realize in a clinical therapeutic use. Instead, we design here an LPETG-EGFP (leucine, proline, glutamic, threonine and glycine-enhanced green fluorescence) protein displayed on a yeast surface as a substrate by adaptively reducing the cost. We do this by optimizing the induction conditions of sortase A expression in Escherichia coli DE3(BL21) and catalyzing LPETG proteins, which are displayed on surface of Pichia pastoris . Different expression conditions of sortase A include: induction temperature (22 °C, 28 °C, 37 °C and 40 °C), induction time (4 h, 5 h, 6 h and 7 h) and induction concentration of isopropyl β-d-thiogalactoside IPTG (0.25 mmol/L, 0.5 mmol/L, 1 mmol/L, and 2 mmol/L). The fluorescence change of the LPETG-EGFP protein on the surface of P. pastoris over time was detected by flow cytometry and fluorescence spectrophotometry, and then the sensitivities of the two methods were compared. Using berberine chloride as an inhibitor, the activity of sortase A was investigated with the substrates of LPETG-EGFP protein, and compared to Dabcyl-QALPETGEE-Edans. A high yield of sortase A was achieved by inducing 1.0 mmol/L IPTG at 28 °C for 6 h. The intensity of green fluorescence of substrates displayed on the yeast surface was increased over time, while the stability was decreased slightly. Both fluorescence spectrophotometery and flow cytometry were fit for detection because of their high sensitivity. We utilized two different substrates of sortase A to investigate sortase A activity, which resulted in the increase of fluorescence intensity with respect to the increased time of growth. However, the method with Dabcyl-QALPETGEE-Edans as its substrate was more robust. Thus, the method described in this paper is a simple and cheap method which is very suitable for

  4. Fluorometric method for inorganic pyrophosphatase activity detection and inhibitor screening based on click chemistry.

    PubMed

    Xu, Kefeng; Chen, Zhonghui; Zhou, Ling; Zheng, Ou; Wu, Xiaoping; Guo, Longhua; Qiu, Bin; Lin, Zhenyu; Chen, Guonan

    2015-01-06

    A fluorometric method for pyrophosphatase (PPase) activity detection was developed based on click chemistry. Cu(II) can coordinate with pyrophosphate (PPi), the addition of pyrophosphatase (PPase) into the above system can destroy the coordinate compound because PPase catalyzes the hydrolysis of PPi into inorganic phosphate and produces free Cu(II), and free Cu(II) can be reduced by sodium ascorbate (SA) to form Cu(I), which in turn initiates the ligating reaction between nonfluorescent 3-azidocoumarins and terminal alkynes to produce a highly fluorescent triazole complex, based on which, a simple and sensitive turn on fluorometric method for PPase can be developed. The fluorescence intensity of the system has a linear relationship with the logarithm of the PPase concentration in the range of 0.5 and 10 mU with a detection limit down to 0.2 mU (S/N = 3). This method is cost-effective and convenient without any labels or complicated operations. The proposed system was applied to screen the potential PPase inhibitor with high efficiency. The proposed method can be applied to diagnosis of PPase-related diseases.

  5. A method for fast safety screening of explosives in terms of crystal packing and molecular stability.

    PubMed

    Hu, Xiaohua; Chen, Nana; Li, Weichen

    2016-07-01

    Safety prediction is crucial to the molecular design or the material design of explosives, and the predictions based on any single factor alone will cause much inaccuracy, leading to a desire for a method on multi-bases. The presented proposes an improved method for fast screening explosive safety by combining a crystal packing factor and a molecular one, that is, steric hindrance against shear slide in crystal and molecular stability, denoted by intermolecular friction symbol (IFS) and bond dissociation energy (BDE) of trigger linkage respectively. Employing this BDE-IFS combined method, we understand the impact sensitivities of 24 existing explosives, and predict those of two energetic-energetic cocrystals of the observed CL-20/BTF and the supposed HMX/TATB. As a result, a better understanding is implemented by the combined method relative to molecular stability alone, verifying its improvement of more accurate predictions and the feasibility of IFS to graphically reflect molecular stacking in crystals. Also, this work verifies that the explosive safety is strongly related with its crystal stacking, which determines steric hindrance and influences shear slide.

  6. Establishment of cocrystal cocktail grinding method for rational screening of pharmaceutical cocrystals.

    PubMed

    Yamamoto, Katsuhiko; Tsutsumi, Shunichirou; Ikeda, Yukihiro

    2012-11-01

    Cocrystals (CCs) used in the pharmaceutical industry are defined as complex crystals formed by reaction between an API and a cocrystal former (CCF); unlike salts, CCs do not show proton transfer. Recently, pharmaceutical CCs have been used to improve the drug-likeness of APIs, such as solubility and stability. Grinding is more effective for CC synthesis than crystallization from solution because in the former case, the API can predominantly interact with the CCF without being affected by solvents. However, this method is tedious because the API is ground with only one CCF at a time. We developed a cocktail cocrystal grinding (CCG) method, in which a mixture of CCFs having the same functional group was used. No false negatives/positives were observed in CCG when carbamazepine was used as the model compound. This method could be used to obtain CCs of piroxicam and spironolactone. False negatives were observed for only one compound from among three model compounds, indicating that CCG facilitates efficient CC detection and that it has higher throughput than does the conventional method. Further, CCG is fast and suitable for rational CC screening, and it helps identify the partial structure of CCFs that forms synthons with an API. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. A new screening method for flunitrazepam in vodka and tequila by fluorescence spectroscopy.

    PubMed

    Leesakul, Nararak; Pongampai, Sirintip; Kanatharana, Proespichaya; Sudkeaw, Pravit; Tantirungrotechai, Yuthana; Buranachai, Chittanon

    2013-01-01

    A new screening method for flunitrazepam in colourless alcoholic beverages based on a spectroscopic technique is proposed. Absorption and steady-state fluorescence of flunitrazepam and its protonated form with various acids were investigated. The redshift of the wavelength of maximum absorption was distinctively observed in protonated flunitrazepam. An emissive fluorescence at 472 nm was detected in colourless spirits (vodka and tequila) at room temperature. 2-M perchloric acid was the most appropriated proton source. By using electron ionization mass spectrometry and time-dependent density functional theory calculations, the possible structure of protonated flunitrazepam was identified to be 2-nitro-N-methylacridone, an acridone derivative as opposed to 2-methylamino-5-nitro-2'-fluorobenzophenone, a benzophenone derivative. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Directed differentiation of embryonic stem cells using a bead-based combinatorial screening method.

    PubMed

    Tarunina, Marina; Hernandez, Diana; Johnson, Christopher J; Rybtsov, Stanislav; Ramathas, Vidya; Jeyakumar, Mylvaganam; Watson, Thomas; Hook, Lilian; Medvinsky, Alexander; Mason, Chris; Choo, Yen

    2014-01-01

    We have developed a rapid, bead-based combinatorial screening method to determine optimal combinations of variables that direct stem cell differentiation to produce known or novel cell types having pre-determined characteristics. Here we describe three experiments comprising stepwise exposure of mouse or human embryonic cells to 10,000 combinations of serum-free differentiation media, through which we discovered multiple novel, efficient and robust protocols to generate a number of specific hematopoietic and neural lineages. We further demonstrate that the technology can be used to optimize existing protocols in order to substitute costly growth factors with bioactive small molecules and/or increase cell yield, and to identify in vitro conditions for the production of rare developmental intermediates such as an embryonic lymphoid progenitor cell that has not previously been reported.

  9. A High-Throughput Screening Method for Identification of Inhibitors of the Deubiquitinating Enzyme USP14

    PubMed Central

    Lee, Byung-Hoon; Finley, Daniel; King, Randall W.

    2013-01-01

    Deubiquitinating enzymes (DUBs) reverse the process of ubiquitination, and number nearly 100 in humans. In principle, DUBs represent promising drug targets, as several of the enzymes have been implicated in human diseases. The isopeptidase activity of DUBs can be selectively inhibited by targeting the catalytic site with drug-like compounds. Notably, the mammalian 26S proteasome is associated with three major DUBs: RPN11, UCH37 and USP14. Because the ubiquitin ‘chain-trimming’ activity of USP14 can inhibit proteasome function, inhibitors of USP14 can stimulate proteasomal degradation. We recently established a high-throughput screening (HTS) method to discover small-molecule inhibitors specific for USP14. The protocols in this article cover the necessary procedures for preparing assay reagents, performing HTS for USP14 inhibitors, and carrying out post-HTS analysis. PMID:23788557

  10. Directed Differentiation of Embryonic Stem Cells Using a Bead-Based Combinatorial Screening Method

    PubMed Central

    Tarunina, Marina; Hernandez, Diana; Johnson, Christopher J.; Rybtsov, Stanislav; Ramathas, Vidya; Jeyakumar, Mylvaganam; Watson, Thomas; Hook, Lilian; Medvinsky, Alexander; Mason, Chris; Choo, Yen

    2014-01-01

    We have developed a rapid, bead-based combinatorial screening method to determine optimal combinations of variables that direct stem cell differentiation to produce known or novel cell types having pre-determined characteristics. Here we describe three experiments comprising stepwise exposure of mouse or human embryonic cells to 10,000 combinations of serum-free differentiation media, through which we discovered multiple novel, efficient and robust protocols to generate a number of specific hematopoietic and neural lineages. We further demonstrate that the technology can be used to optimize existing protocols in order to substitute costly growth factors with bioactive small molecules and/or increase cell yield, and to identify in vitro conditions for the production of rare developmental intermediates such as an embryonic lymphoid progenitor cell that has not previously been reported. PMID:25251366

  11. Infrared thermography based on artificial intelligence as a screening method for carpal tunnel syndrome diagnosis.

    PubMed

    Jesensek Papez, B; Palfy, M; Mertik, M; Turk, Z

    2009-01-01

    This study further evaluated a computer-based infrared thermography (IRT) system, which employs artificial neural networks for the diagnosis of carpal tunnel syndrome (CTS) using a large database of 502 thermal images of the dorsal and palmar side of 132 healthy and 119 pathological hands. It confirmed the hypothesis that the dorsal side of the hand is of greater importance than the palmar side when diagnosing CTS thermographically. Using this method it was possible correctly to classify 72.2% of all hands (healthy and pathological) based on dorsal images and > 80% of hands when only severely affected and healthy hands were considered. Compared with the gold standard electromyographic diagnosis of CTS, IRT cannot be recommended as an adequate diagnostic tool when exact severity level diagnosis is required, however we conclude that IRT could be used as a screening tool for severe cases in populations with high ergonomic risk factors of CTS.

  12. A fast boosting-based screening method for large-scale association study in complex traits with genetic heterogeneity.

    PubMed

    Wang, Lu-Yong; Fasulo, D

    2006-01-01

    Genome-wide association study for complex diseases will generate massive amount of single nucleotide polymorphisms (SNPs) data. Univariate statistical test (i.e. Fisher exact test) was used to single out non-associated SNPs. However, the disease-susceptible SNPs may have little marginal effects in population and are unlikely to retain after the univariate tests. Also, model-based methods are impractical for large-scale dataset. Moreover, genetic heterogeneity makes the traditional methods harder to identify the genetic causes of diseases. A more recent random forest method provides a more robust method for screening the SNPs in thousands scale. However, for more large-scale data, i.e., Affymetrix Human Mapping 100K GeneChip data, a faster screening method is required to screening SNPs in whole-genome large scale association analysis with genetic heterogeneity. We propose a boosting-based method for rapid screening in large-scale analysis of complex traits in the presence of genetic heterogeneity. It provides a relatively fast and fairly good tool for screening and limiting the candidate SNPs for further more complex computational modeling task.

  13. In-vivo Reflectance Measurements from Human Skin

    NASA Astrophysics Data System (ADS)

    Delgado, J. A.; Cornejo, A.; Cunill, M.; Báez, J. J.; Matos, R.; Anasagasti, L.; Santiago, C.

    2006-09-01

    We evaluate the potential of using a standard commercial spectrophotometer, specifically designed to meet the growing requirement for color control in the digital-imaging application field, to perform in-vivo diffuse reflectance measurements from adult human skin. We report and discuss diffuse reflectance spectra for three practical situations: a) reflectance versus skin type, b) reflectance from normal skin with different grade of solar exposition, c) reflectance from normal skin versus reflectance from seborrheic keratosis. Results show, that using the above spectrophotometer we can easily differentiate two sites of different solar exposition. Besides, significant differences are found in the normal skin diffuse reflectance for patients with different skin types.

  14. Noninvasive Assessment of Excessive Erythrocytosis as a Screening Method for Chronic Mountain Sickness at High Altitude.

    PubMed

    Vyas, Kaetan J; Danz, David; Gilman, Robert H; Wise, Robert A; León-Velarde, Fabiola; Miranda, J Jaime; Checkley, William

    2015-06-01

    Vyas, Kaetan J., David Danz, Robert H. Gilman, Robert A. Wise, Fabiola León-Velarde, J. Jaime Miranda, and William Checkley. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt Med Biol 16:162-168, 2015.--Globally, over 140 million people are at risk of developing chronic mountain sickness, a common maladaptation to life at high altitude (>2500 meters above sea level). The diagnosis is contingent upon the identification of excessive erythrocytosis (EE). Current best practices to identify EE require a venous blood draw, which is cumbersome for large-scale surveillance. We evaluated two point-of-care biomarkers to screen for EE: noninvasive spot-check tests of total hemoglobin and oxyhemoglobin saturation (Pronto-7, Masimo Corporation). We conducted paired evaluations of total serum hemoglobin from a venous blood draw and noninvasive, spot-check testing of total hemoglobin and oxyhemoglobin saturation with the Pronto-7 in 382 adults aged ≥35 years living in Puno, Peru (3825 meters above sea level). We used the Bland-Altman method to measure agreement between the noninvasive hemoglobin assessment and the gold standard lab hemoglobin analyzer. Mean age was 58.8 years and 47% were male. The Pronto-7 test was unsuccessful in 21 (5%) participants. Limits of agreement between total hemoglobin measured via venous blood draw and the noninvasive, spot-check test ranged from -2.8 g/dL (95% CI -3.0 to -2.5) to 2.5 g/dL (95% CI 2.2 to 2.7), with a bias of -0.2 g/dL (95% CI -0.3 to -0.02) for the difference between total hemoglobin and noninvasive hemoglobin concentrations. Overall, the noninvasive spot-check test of total hemoglobin had a better area under the receiver operating characteristic curve compared to oxyhemoglobin saturation for the identification of EE as measured by a gold standard laboratory hemoglobin analyzer (0.96 vs. 0.82; p<0.001). Best cut-off values to screen for EE with

  15. Computer screening for palliative care needs in primary care: a mixed-methods study.

    PubMed

    Mason, Bruce; Boyd, Kirsty; Steyn, John; Kendall, Marilyn; Macpherson, Stella; Murray, Scott A

    2018-05-01

    Though the majority of people could benefit from palliative care before they die, most do not receive this approach, especially those with multimorbidity and frailty. GPs find it difficult to identify such patients. To refine and evaluate the utility of a computer application (AnticiPal) to help primary care teams screen their registered patients for people who could benefit from palliative care. A mixed-methods study of eight GP practices in Scotland, conducted in 2016-2017. After a search development cycle the authors adopted a mixed-methods approach, combining analysis of the number of people identified by the search with qualitative observations of the computer search as used by primary care teams, and interviews with professionals and patients. The search identified 0.8% of 62 708 registered patients. A total of 27 multidisciplinary meetings were observed, and eight GPs and 10 patients were interviewed. GPs thought the search identified many unrecognised patients with advanced multimorbidity and frailty, but were concerned about workload implications of assessment and care planning. Patients and carers endorsed the value of proactive identification of people with advanced illness. GP practices can use computer searching to generate lists of patients for review and care planning. The challenges of starting a conversation about the future remain. However, most patients regard key components of palliative care (proactive planning, including sharing information with urgent care services) as important. Screening for people with deteriorating health at risk from unplanned care is a current focus for quality improvement and should not be limited by labelling it solely as 'palliative care'. © British Journal of General Practice 2018.

  16. Who benefit from school doctors' health checks: a prospective study of a screening method.

    PubMed

    Nikander, Kirsi; Kosola, Silja; Kaila, Minna; Hermanson, Elina

    2018-06-27

    School health services provide an excellent opportunity for the detection and treatment of children at risk of later health problems. However, the optimal use of school doctors' skills and expertise remains unknown. Furthermore, no validated method for screening children for school doctors' assessments exists. The aims of the study are 1) to evaluate the benefits or harm of school doctors' routine health checks in primary school grades 1 and 5 (at ages 7 and 11) and 2) to explore whether some of the school doctors' routine health checks can be omitted using study questionnaires. This is a prospective, multicenter observational study conducted in four urban municipalities in Southern Finland by comparing the need for a school doctor's assessment to the benefit gained from it. We will recruit a random sample of 1050 children from 21 schools from primary school grades 1 and 5. Before the school doctor's health check, parents, nurses and teachers fill a study questionnaire to identify any potential concerns about each child. Doctors, blinded to the questionnaire responses, complete an electronic report after the appointment, including given instructions and follow-up plans. The child, parent, doctor and researchers assess the benefit of the health check. The researchers compare the need for a doctor's appointment to the benefit gained from it. At one year after the health check, we will analyze the implementation of the doctors' interventions and follow-up plans. The study will increase our knowledge of the benefits of school doctors' routine health checks and assess the developed screening method. We hypothesize that targeting the health checks to the children in greatest need would increase the quality of school health services. ClinicalTrials.gov Identifier: NCT03178331 , date of registration June 6 th 2017.

  17. A novel tandem mass spectrometry method for first-line screening of mainly beta-thalassemia from dried blood spots.

    PubMed

    Yu, Chaowen; Huang, Shuodan; Wang, Ming; Zhang, Juan; Liu, Hao; Yuan, Zhaojian; Wang, Xingbin; He, Xiaoyan; Wang, Jie; Zou, Lin

    2017-02-10

    Traditional methods for thalassemia screening are time-consuming and easily affected by cell hemolysis or hemoglobin degradation in stored blood samples. Tandem mass spectrometry (MS/MS) proved to be an effective technology for sickle cell disorders (SCD) screening. Here, we developed a novel MS/MS method for β-thalassemia screening from dried blood spots (DBS). Stable isotopic-labeled peptides were used as internal standards for quantification and calculation of the α:β-globin ratios. We used the α:β-globin ratio cutoffs to differentiate between normal individuals and patients with thalassemia. About 781 patients and 300 normal individuals were analyzed. The α:β-globin ratios showed significant difference between normal and β-thalassemia patients (P<0.01), particularly when the disease was homozygous or double heterozygous with another α- or β-thalassemia mutation. In the parallel study, all cases screened for suspected thalassemia from six hundred DBS samples by using this MS/MS method were successfully confirmed by genotyping. The intra-assay and inter-assay CVs of the ratios ranged from 2.4% to 3.9% and 4.7% to 7.1%, and there was no significant sample carryover or matrix effect for this MS/MS method. Combined with SCD screening, this MS/MS method could be used as a first-line screening assay for both structural and expression abnormalities of human hemoglobin. Traditional methods for thalassemia screening were depending on the structural integrity of tetramers and could be affected by hemolysis and degradation of whole blood samples, especially when stored. We used proteospecific peptides produced by the tryptic digestion of each globin to evaluate the production ratio between α- and β-globin chains, which turned out to be quite stable even when stored for more than two months. Though most of the peptides were specific to α-globin or β-globin, we only chose four most informative peptides and its stable isotopic-labeled peptides as internal

  18. Anti-cancer effects of baicalein in non-small cell lung cancer in-vitro and in-vivo.

    PubMed

    Cathcart, Mary-Clare; Useckaite, Zivile; Drakeford, Clive; Semik, Vikki; Lysaght, Joanne; Gately, Kathy; O'Byrne, Kenneth J; Pidgeon, Graham P

    2016-09-01

    Baicalein is a widely used Chinese herbal medicine derived from Scutellaria baicalenesis, which has been traditionally used as anti-inflammatory and anti-cancer therapy. In this study we examined the anti-tumour pathways activated following baicalein treatment in non-small cell lung cancer (NSCLC), both in-vitro and in-vivo. The effect of baicalein treatment on H-460 cells in-vitro was assessed using both BrdU assay (cell proliferation) and High Content Screening (multi-parameter apoptosis assay). A xenograft nude mouse model was subsequently established using these cells and the effect of baicalein on tumour growth and survival assessed in-vivo. Tumours were harvested from these mice and histological tissue analysis carried out. VEGF, 12-lipoxygenase and microvessel density (CD-31) were assessed by immunohistochemistry (IHC), while H and E staining was carried out to assess mitotic index. Gene expression profiling was carried out on corresponding RNA samples using Human Cancer Pathway Finder Arrays and qRT-PCR, with further gene expression analysis carried out using qRT-PCR. Baicalein significantly decreased lung cancer proliferation in H-460 cells in a dose dependent manner. At the functional level, a dose-dependent induction in apoptosis associated with decreased cellular f-actin content, an increase in nuclear condensation and an increase in mitochondrial mass potential was observed. Orthotopic treatment of experimental H-460 tumours in athymic nude mice with baicalein significantly (p < 0.05) reduced tumour growth and prolonged survival. Histological analysis of resulting tumour xenografts demonstrated reduced expression of both 12-lipoxygenase and VEGF proteins in baicalein-treated tumours, relative to untreated. A significant (p < 0.01) reduction in both mitotic index and micro-vessel density was observed following baicalein treatment. Gene expression profiling revealed a reduction (p < 0.01) in both VEGF and FGFR-2 following baicalein treatment

  19. Rapid, convenient method for screening imidazole-containing compounds for heme oxygenase inhibition.

    PubMed

    Vlahakis, Jason Z; Rahman, Mona N; Roman, Gheorghe; Jia, Zongchao; Nakatsu, Kanji; Szarek, Walter A

    2011-01-01

    Sensitive assays for measuring heme oxygenase activity have been based on the gas-chromatographic detection of carbon monoxide using elaborate, expensive equipment. The present study describes a rapid and convenient method for screening imidazole-containing candidates for inhibitory activity against heme oxygenase using a plate reader, based on the spectroscopic evaluation of heme degradation. A PowerWave XS plate reader was used to monitor the absorbance (as a function of time) of heme bound to purified truncated human heme oxygenase-1 (hHO-1) in the individual wells of a standard 96-well plate (with or without the addition of a test compound). The degradation of heme by heme oxygenase-1 was initiated using l-ascorbic acid, and the collected relevant absorbance data were analyzed by three different methods to calculate the percent control activity occurring in wells containing test compounds relative to that occurring in control wells with no test compound present. In the cases of wells containing inhibitory compounds, significant shifts in λ(max) from 404 to near 412 nm were observed as well as a decrease in the rate of heme degradation relative to that of the control. Each of the three methods of data processing (overall percent drop in absorbance over 1.5h, initial rate of reaction determined over the first 5 min, and estimated pseudo first-order reaction rate constant determined over 1.5h) gave similar and reproducible results for percent control activity. The fastest and easiest method of data analysis was determined to be that using initial rates, involving data acquisition for only 5 min once reactions have been initiated using l-ascorbic acid. The results of the study demonstrate that this simple assay based on the spectroscopic detection of heme represents a rapid, convenient method to determine the relative inhibitory activity of candidate compounds, and is useful in quickly screening a series or library of compounds for heme oxygenase inhibition

  20. FMM-Yukawa: An adaptive fast multipole method for screened Coulomb interactions

    NASA Astrophysics Data System (ADS)

    Huang, Jingfang; Jia, Jun; Zhang, Bo

    2009-11-01

    A Fortran program package is introduced for the rapid evaluation of the screened Coulomb interactions of N particles in three dimensions. The method utilizes an adaptive oct-tree structure, and is based on the new version of fast multipole method in which the exponential expansions are used to diagonalize the multipole-to-local translations. The program and its full description, as well as several closely related packages are also available at http://www.fastmultipole.org/. This paper is a brief review of the program and its performance. Catalogue identifier: AEEQ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEQ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GPL 2.0 No. of lines in distributed program, including test data, etc.: 12 385 No. of bytes in distributed program, including test data, etc.: 79 222 Distribution format: tar.gz Programming language: Fortran77 and Fortran90 Computer: Any Operating system: Any RAM: Depends on the number of particles, their distribution, and the adaptive tree structure Classification: 4.8, 4.12 Nature of problem: To evaluate the screened Coulomb potential and force field of N charged particles, and to evaluate a convolution type integral where the Green's function is the fundamental solution of the modified Helmholtz equation. Solution method: An adaptive oct-tree is generated, and a new version of fast multipole method is applied in which the "multipole-to-local" translation operator is diagonalized. Restrictions: Only three and six significant digits accuracy options are provided in this version. Unusual features: Most of the codes are written in

  1. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers.

    PubMed

    Avonto, Cristina; Chittiboyina, Amar G; Rua, Diego; Khan, Ikhlas A

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, 'HTS-DCYA assay', is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  3. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    PubMed

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Screening possible solid electrolytes by calculating the conduction pathways using Bond Valence method

    NASA Astrophysics Data System (ADS)

    Gao, Jian; Chu, Geng; He, Meng; Zhang, Shu; Xiao, RuiJuan; Li, Hong; Chen, LiQuan

    2014-08-01

    Inorganic solid electrolytes have distinguished advantages in terms of safety and stability, and are promising to substitute for conventional organic liquid electrolytes. However, low ionic conductivity of typical candidates is the key problem. As connective diffusion path is the prerequisite for high performance, we screen for possible solid electrolytes from the 2004 International Centre for Diffraction Data (ICDD) database by calculating conduction pathways using Bond Valence (BV) method. There are 109846 inorganic crystals in the 2004 ICDD database, and 5295 of them contain lithium. Except for those with toxic, radioactive, rare, or variable valence elements, 1380 materials are candidates for solid electrolytes. The rationality of the BV method is approved by comparing the existing solid electrolytes' conduction pathways we had calculated with those from experiments or first principle calculations. The implication for doping and substitution, two important ways to improve the conductivity, is also discussed. Among them Li2CO3 is selected for a detailed comparison, and the pathway is reproduced well with that based on the density functional studies. To reveal the correlation between connectivity of pathways and conductivity, α/ γ-LiAlO2 and Li2CO3 are investigated by the impedance spectrum as an example, and many experimental and theoretical studies are in process to indicate the relationship between property and structure. The BV method can calculate one material within a few minutes, providing an efficient way to lock onto targets from abundant data, and to investigate the structure-property relationship systematically.

  5. Methods for transforming and expression screening of filamentous fungal cells with a DNA library

    DOEpatents

    Teter, Sarah; Lamsa, Michael; Cherry, Joel; Ward, Connie

    2015-06-02

    The present invention relates to methods for expression screening of filamentous fungal transformants, comprising: (a) isolating single colony transformants of a DNA library introduced into E. coli; (b) preparing DNA from each of the single colony E. coli transformants; (c) introducing a sample of each of the DNA preparations of step (b) into separate suspensions of protoplasts of a filamentous fungus to obtain transformants thereof, wherein each transformant contains one or more copies of an individual polynucleotide from the DNA library; (d) growing the individual filamentous fungal transformants of step (c) on selective growth medium, thereby permitting growth of the filamentous fungal transformants, while suppressing growth of untransformed filamentous fungi; and (e) measuring activity or a property of each polypeptide encoded by the individual polynucleotides. The present invention also relates to isolated polynucleotides encoding polypeptides of interest obtained by such methods, to nucleic acid constructs, expression vectors, and recombinant host cells comprising the isolated polynucleotides, and to methods of producing the polypeptides encoded by the isolated polynucleotides.

  6. Screening and identification of radical scavengers from Neo-Taraxacum siphonanthum by online rapid screening method and nuclear magnetic resonance experiments.

    PubMed

    Shi, Shu Yun; Zhang, Yu Ping; Zhou, Hong Hao; Huang, Ke Long; Jiang, Xin Yu

    2010-01-01

    An online rapid screening method, the high-performance liquid chromatography (HPLC)-diode array detector (DAD)-radical scavenging detection (RSD)-electrospray ionization (ESI)-mass spectroscopy (MS)/MS system, was developed for the screening and identification of radical scavengers from Neo-Taraxacum siphonanthum, a new species found in China in 1989. For further characterization, the target compounds were isolated by silica column chromatography, preparative high-performance liquid chromatography (HPLC), HSCCC, and Sephadex LH-20 column chromatography and elucidated on the basis of ultraviolet (UV), ESI-MS/MS, and nuclear magnetic resonance (NMR) spectroscopy, as well as the chemical analysis. Eighteen antioxidative polyphenols (5 caffeic acid derivatives and 13 flavonoid derivatives) were characterized from Neo-T. siphonanthum. The distribution of all compounds was discussed in a chemosystematic context, which suggested that the genera Neo-Taraxacum and Taraxacum might relate chemosystematically.

  7. From CBCL to DSM: A Comparison of Two Methods to Screen for DSM-IV Diagnoses Using CBCL Data

    ERIC Educational Resources Information Center

    Krol, Nicole P. C. M.; De Bruyn, Eric E. J.; Coolen, Jolanda C.; van Aarle, Edward J. M.

    2006-01-01

    The screening efficiency of 2 methods to convert Child Behavior Checklist (CBCL) assessment data into Diagnostic and Statistical Manual of Mental Disorders (4th ed. [DSM-IV]; American Psychiatric Association, 1994) diagnoses was compared. The Machine-Aided Diagnosis (MAD) method converts CBCL input data directly into DSM-IV symptom criteria. The…

  8. Constraint factor graph cut-based active contour method for automated cellular image segmentation in RNAi screening.

    PubMed

    Chen, C; Li, H; Zhou, X; Wong, S T C

    2008-05-01

    Image-based, high throughput genome-wide RNA interference (RNAi) experiments are increasingly carried out to facilitate the understanding of gene functions in intricate biological processes. Automated screening of such experiments generates a large number of images with great variations in image quality, which makes manual analysis unreasonably time-consuming. Therefore, effective techniques for automatic image analysis are urgently needed, in which segmentation is one of the most important steps. This paper proposes a fully automatic method for cells segmentation in genome-wide RNAi screening images. The method consists of two steps: nuclei and cytoplasm segmentation. Nuclei are extracted and labelled to initialize cytoplasm segmentation. Since the quality of RNAi image is rather poor, a novel scale-adaptive steerable filter is designed to enhance the image in order to extract long and thin protrusions on the spiky cells. Then, constraint factor GCBAC method and morphological algorithms are combined to be an integrated method to segment tight clustered cells. Compared with the results obtained by using seeded watershed and the ground truth, that is, manual labelling results by experts in RNAi screening data, our method achieves higher accuracy. Compared with active contour methods, our method consumes much less time. The positive results indicate that the proposed method can be applied in automatic image analysis of multi-channel image screening data.

  9. Telediagnostic 3D school screening of back curvatures and posture using structured light method - pilot study.

    PubMed

    Glinkowski, Wojciech; Michoński, Jakub; Glinkowska, Bożena; Zukowska, Agnieszka; Sitnik, Robert; Górecki, Andrzej

    2012-01-01

    Several studies consider the school scoliosis screening as controversial. Many authors postulate to improve its clinical effectiveness. Authors assumed that three dimensional telediagnostic surface topography measurements allowing measuring several postural deformity indexes and angles of curvatures in sagittal plane may enhance current practice. The study was designed to determine usefulness of school screening back evaluation performed utilizing the three dimensional telediagnostic measurement system. The measurement module is based on structured light method using "3D Orthoscreen" system. The technique for 3D image acquisition of back shape is based on temporal phase shifting and Gray codes. Measurement data was securely archived for remote access by investigator over the secure Internet connection. Acquired "images" were transferred to Telediagnostic Center for clinical evaluation. Spine parameters and deformation indexes like Posterior Trunk Symmetry Index (POTSI), Deformity in the Axial Plane Index (DAPI), kyphosis and lordosis angle were measured. The preliminary study was performed in 2 selected schools (basic and middle schools). The study was approved by Bioethical Committee. Clouds of points representing back topography of assessed subjects were acquired at schools in March and May 2011 and stored for remote evaluation and analysis. 758 children averagely aged 11.1 years (from 5 to 16), 387 females and 371 males, were examined. Their average body mass was 45.13 kg [16-105; STD 16.4] and average height was 151.43 cm, [110-192; STD 18.3]. The average values of back assessment parameters were as follows: POTSI 15.97% [0-73.4; STD 10.3]; DAPI 0.88% [0-5.9; STD 0.76]; kyphosis angle 10.19° [0-32; STD 5.82]; and lordosis angle 32,82° [0-56; STD 9.86]. Technical and clinical issues of the practical implementation allowed to elaborate preliminary protocol for cohort studies addressed to subject (i.e. parents acceptance of examination of undressed back) and

  10. Comparative effectiveness study on human papillomavirus detection methods used in the cervical cancer screening programme

    PubMed Central

    Nygård, Mari; Røysland, Kjetil; Campbell, Suzanne; Dillner, Joakim

    2014-01-01

    Objectives To compare the short-term and long-term effectiveness of human papillomavirus (HPV) tests in Norwegian Cervical Cancer Screening Programme (NCCSP). Design Nationwide register-based prospective follow-up study. Setting In 2005, the NCCSP implemented HPV testing in follow-up of unsatisfactory, atypical squamous cells of undetermined significance (ASC-US) and low-grade squamous intraepithelial lesion (LSIL) cytology. Participants 19 065 women with repeat cytology and HPV test after unsatisfactory ASC-US or LSIL screening result in 2005–2009. Interventions Through individual registry linkages we observed how women were treated in the regular medical care. Main outcome measures We estimated cumulative incidence of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) in 6 months and 3 years after repeat cytology and HPV test. Patients diagnosed with CIN2+ in 6 months and 3 years were assessed for initial HPV positivity. Results 5392 had ASC-US/LSIL and 13 673 had normal/unsatisfactory repeat cytology; for HPV detection 4715 used AMPLICOR HPV Test (Roche Diagnostics, Basel, Switzerland), 9162 Hybrid Capture 2 (HC2) High-Risk HPV DNA Test (QIAGEN, Gaithersburg, Maryland, USA) and 5188 PreTect HPV-Proofer (NorChip, Klokkarstua, Norway). Among those with ASC-US/LSIL repeat cytology, 3-year risk of CIN2+ was 15-fold in Amplicor/HC2-positives compared with Amplicor/HC2-negatives and sevenfold in Proofer-positives compared with Proofer-negatives; a 3-year risk of CIN2+ was 2.1% (95% CI 0.7% to 3.4%) in Amplicor-negatives and 7.2% (95% CI 5.4% to 8.9%) in Proofer-negatives. Close to 100% of patients with CIN2+ diagnosed within 6 months tested positive to HPV (all methods). Considering all patients diagnosed with CIN2+ in 3-year follow-up, 97% were initially positive in the Amplicor group and more than 94% in the HC2 group, compared with less than 80% in the Proofer group. Conclusions While the long-term evaluation of new screening routines

  11. Evaluation of four rapid methods for hemoglobin screening of whole blood donors in mobile collection settings.

    PubMed

    Gómez-Simón, Antonia; Navarro-Núñez, Leyre; Pérez-Ceballos, Elena; Lozano, María L; Candela, María J; Cascales, Almudena; Martínez, Constantino; Corral, Javier; Vicente, Vicente; Rivera, José

    2007-06-01

    Predonation hemoglobin measurement is a problematic requirement in mobile donation settings, where accurate determination of venous hemoglobin by hematology analyzers is not available. We have evaluated hemoglobin screening in prospective donors by the semiquantitative copper sulphate test and by capillary blood samples analyzed by three portable photometers, HemoCue, STAT-Site MHgb, and the CompoLab HB system. Capillary blood samples were obtained from 380 donors and tested by the copper sulphate test and by at least one of the named portable photometers. Predonation venous hemoglobin was also determined in all donors using a Coulter Max-M analyzer. The three photometers provided acceptable reproducibility (CV below 5%), and displayed a significant correlation between the capillary blood samples and the venous hemoglobin (R2 0.5-0.8). HemoCue showed the best agreement with venous hemoglobin determination, followed by STAT-Site MHgb, and the CompoLab HB system. The copper sulphate test provided the highest rate of donors acceptance (83%) despite unacceptable hemoglobin levels, and the lowest rate for donor deferral (1%) despite acceptable hemoglobin levels. The percentage of donors correctly categorized for blood donation by the portable hemoglobinometers was 85%, 82%, and 76% for CompoLab HB system, HemoCue and STAT-Site, respectively. Our data suggest that hemoglobin determination remains a conflictive issue in donor selection in the mobile setting. Without appropriate performance control, capillary hemoglobin screening by either the copper sulphate method or by the novel portable hemoglobinometers could be inaccurate, thus potentially affecting both donor safety and the blood supply.

  12. Utilization of breast cancer screening methods in a developing nation: results from a nationally representative sample of Malaysian households.

    PubMed

    Dunn, Richard A; Tan, Andrew K G

    2011-01-01

    As is the case in many developing nations, previous studies of breast cancer screening behavior in Malaysia have used relatively small samples that are not nationally representative, thereby limiting the generalizability of results. Therefore, this study uses nationally representative data from the Malaysia Non-Communicable Disease Surveillance-1 to investigate the role of socio-economic status on breast cancer screening behavior in Malaysia, particularly differences in screening behaviour between ethnic groups. The decisions of 816 women above age 40 in Malaysia to screen for breast cancer using mammography, clinical breast exams (CBE), and breast self-exams (BSE) are modeled using logistic regression. Results indicate that after adjusting for differences in age, education, household income, marital status, and residential location, Malay women are less likely than Chinese and Indian women to utilize mammography, but more likely to perform BSE. Education level and urban residence are positively associated with utilization of each method, but these relationships vary across ethnicity. Higher education levels are strongly related to using each screening method among Chinese women, but have no statistically significant relationship to screening among Malays. © 2011 Wiley Periodicals, Inc.

  13. In-Vivo Fluorescence Spectroscopy Of Normal And Atherosclerotic Arteries

    NASA Astrophysics Data System (ADS)

    Deckelbaum, Lawrence I.; Sarembock, Ian J.; Stetz, Mark L.; O'Brien, Kenneth M.; Cutruzzola, Francis W.; Gmitro, Arthur F.; Ezekowitz, Michael D.

    1988-06-01

    Laser-induced fluorescence spectroscopy can discriminate atherosclerotic from normal arteries in-vitro and may thus potentially guide laser angioplasty. To evaluate the feasibility of laser-induced fluorescence spectroscopy in a living blood-filled arterial system we performed fiberoptic laser-induced fluorescence spectroscopy in a rabbit model of focal femoral atherosclerosis. A laser-induced fluorescence spectroscopy score was derived from stepwise linear regression analysis of in-vitro spectra to distinguish normal aorta (score>0) from atherosclerotic femoral artery (score<0). A 400 u silica fiber, coupled to a helium cadmium laser and optical multichannel analyzer, was inserted through a 5F catheter to induce and record in-vivo fluorescence from femoral and aortoiliac arteries. Arterial spectra could be recorded in all animals (n=10: 5 occlusions, 5 stenoses). Blood spectra were of low intensity and were easily distinguished from arterial spectra. The scores (mean ± SEM) for the in-vivo spectra were -0.69 +/- 0.29 for artherosclerotic femoral, and +0.54 ±. 0.15 for normal aorta (p<.01 p=NS compared to in-vitro spectra). In-vitro, a fiber tip to tissue distance <50 u was necessary for adequate arterial LIFS in blood. At larger distances low intensity blood spectra were recorded (1/20 the intensity of tissue spectra). Thus, fiberoptic laser-induced fluorescence spectroscopy can be sucessfully performed in a blood filled artery provided the fiber tip is approximated to the tissue.

  14. In-vivo digital wavefront sensing using swept source OCT

    PubMed Central

    Kumar, Abhishek; Wurster, Lara M.; Salas, Matthias; Ginner, Laurin; Drexler, Wolfgang; Leitgeb, Rainer A.

    2017-01-01

    Sub-aperture based digital adaptive optics is demonstrated in a fiber based point scanning optical coherence tomography system using a 1060 nm swept source laser. To detect optical aberrations in-vivo, a small lateral field of view of ~150×150 μm2 is scanned on the sample at a high volume rate of 17 Hz (~1.3 kHz B-scan rate) to avoid any significant lateral and axial motion of the sample, and is used as a “guide star” for the sub-aperture based DAO. The proof of principle is demonstrated using a micro-beads phantom sample, wherein a significant root mean square wavefront error (RMS WFE) of 1.48 waves (> 1μm) is detected. In-vivo aberration measurement with a RMS WFE of 0.33 waves, which is ~5 times higher than the Marechal’s criterion of 1/14 waves for the diffraction limited performance, is shown for a human retinal OCT. Attempt has been made to validate the experimental results with the conventional Shack-Hartmann wavefront sensor within reasonable limitations. PMID:28717573

  15. HIM-herbal ingredients in-vivo metabolism database.

    PubMed

    Kang, Hong; Tang, Kailin; Liu, Qi; Sun, Yi; Huang, Qi; Zhu, Ruixin; Gao, Jun; Zhang, Duanfeng; Huang, Chenggang; Cao, Zhiwei

    2013-05-31

    Herbal medicine has long been viewed as a valuable asset for potential new drug discovery and herbal ingredients' metabolites, especially the in vivo metabolites were often found to gain better pharmacological, pharmacokinetic and even better safety profiles compared to their parent compounds. However, these herbal metabolite information is still scattered and waiting to be collected. HIM database manually collected so far the most comprehensive available in-vivo metabolism information for herbal active ingredients, as well as their corresponding bioactivity, organs and/or tissues distribution, toxicity, ADME and the clinical research profile. Currently HIM contains 361 ingredients and 1104 corresponding in-vivo metabolites from 673 reputable herbs. Tools of structural similarity, substructure search and Lipinski's Rule of Five are also provided. Various links were made to PubChem, PubMed, TCM-ID (Traditional Chinese Medicine Information database) and HIT (Herbal ingredients' targets databases). A curated database HIM is set up for the in vivo metabolites information of the active ingredients for Chinese herbs, together with their corresponding bioactivity, toxicity and ADME profile. HIM is freely accessible to academic researchers at http://www.bioinformatics.org.cn/.

  16. How to benchmark methods for structure-based virtual screening of large compound libraries.

    PubMed

    Christofferson, Andrew J; Huang, Niu

    2012-01-01

    Structure-based virtual screening is a useful computational technique for ligand discovery. To systematically evaluate different docking approaches, it is important to have a consistent benchmarking protocol that is both relevant and unbiased. Here, we describe the designing of a benchmarking data set for docking screen assessment, a standard docking screening process, and the analysis and presentation of the enrichment of annotated ligands among a background decoy database.

  17. Efficacy of ACL injury risk screening methods in identifying high-risk landing patterns during a sport-specific task.

    PubMed

    Fox, A S; Bonacci, J; McLean, S G; Saunders, N

    2017-05-01

    Screening methods sensitive to movement strategies that increase anterior cruciate ligament (ACL) loads are likely to be effective in identifying athletes at-risk of ACL injury. Current ACL injury risk screening methods are yet to be evaluated for their ability to identify athletes' who exhibit high-risk lower limb mechanics during sport-specific maneuvers associated with ACL injury occurrences. The purpose of this study was to examine the efficacy of two ACL injury risk screening methods in identifying high-risk lower limb mechanics during a sport-specific landing task. Thirty-two female athletes were screened using the Landing Error Scoring System (LESS) and Tuck Jump Assessment. Participants' also completed a sport-specific landing task, during which three-dimensional kinematic and kinetic data were collected. One-dimensional statistical parametric mapping was used to examine the relationships between screening method scores, and the three-dimensional hip and knee joint rotation and moment data from the sport-specific landing. Higher LESS scores were associated with reduced knee flexion from 30 to 57 ms after initial contact (P = 0.003) during the sport-specific landing; however, no additional relationships were found. These findings suggest the LESS and Tuck Jump Assessment may have minimal applicability in identifying athletes' who exhibit high-risk landing postures in the sport-specific task examined. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Reliability of Phase Velocity Measurements of Flexural Acoustic Waves in the Human Tibia In-Vivo.

    PubMed

    Vogl, Florian; Schnüriger, Karin; Gerber, Hans; Taylor, William R

    2016-01-01

    Axial-transmission acoustics have shown to be a promising technique to measure individual bone properties and detect bone pathologies. With the ultimate goal being the in-vivo application of such systems, quantification of the key aspects governing the reliability is crucial to bring this method towards clinical use. This work presents a systematic reliability study quantifying the sources of variability and their magnitudes of in-vivo measurements using axial-transmission acoustics. 42 healthy subjects were measured by an experienced operator twice per week, over a four-month period, resulting in over 150000 wave measurements. In a complementary study to assess the influence of different operators performing the measurements, 10 novice operators were trained, and each measured 5 subjects on a single occasion, using the same measurement protocol as in the first part of the study. The estimated standard error for the measurement protocol used to collect the study data was ∼ 17 m/s (∼ 4% of the grand mean) and the index of dependability, as a measure of reliability, was Φ = 0.81. It was shown that the method is suitable for multi-operator use and that the reliability can be improved efficiently by additional measurements with device repositioning, while additional measurements without repositioning cannot improve the reliability substantially. Phase velocity values were found to be significantly higher in males than in females (p < 10-5) and an intra-class correlation coefficient of r = 0.70 was found between the legs of each subject. The high reliability of this non-invasive approach and its intrinsic sensitivity to mechanical properties opens perspectives for the rapid and inexpensive clinical assessment of bone pathologies, as well as for monitoring programmes without any radiation exposure for the patient.

  19. Frailty screening methods for predicting outcome of a comprehensive geriatric assessment in elderly patients with cancer: a systematic review.

    PubMed

    Hamaker, Marije E; Jonker, Judith M; de Rooij, Sophia E; Vos, Alinda G; Smorenburg, Carolien H; van Munster, Barbara C

    2012-10-01

    Comprehensive geriatric assessment (CGA) is done to detect vulnerability in elderly patients with cancer so that treatment can be adjusted accordingly; however, this process is time-consuming and pre-screening is often used to identify fit patients who are able to receive standard treatment versus those in whom a full CGA should be done. We aimed to assess which of the frailty screening methods available show the best sensitivity and specificity for predicting the presence of impairments on CGA in elderly patients with cancer. We did a systematic search of Medline and Embase, and a hand-search of conference abstracts, for studies on the association between frailty screening outcome and results of CGA in elderly patients with cancer. Our search identified 4440 reports, of which 22 publications from 14 studies, were included in this Review. Seven different frailty screening methods were assessed. The median sensitivity and specificity of each screening method for predicting frailty on CGA were as follows: Vulnerable Elders Survey-13 (VES-13), 68% and 78%; Geriatric 8 (G8), 87% and 61%; Triage Risk Screening Tool (TRST 1+; patient considered frail if one or more impairments present), 92% and 47%, Groningen Frailty Index (GFI) 57% and 86%, Fried frailty criteria 31% and 91%, Barber 59% and 79%, and abbreviated CGA (aCGA) 51% and 97%. However, even in case of the highest sensitivity, the negative predictive value was only roughly 60%. G8 and TRST 1+ had the highest sensitivity for frailty, but both had poor specificity and negative predictive value. These findings suggest that, for now, it might be beneficial for all elderly patients with cancer to receive a complete geriatric assessment, since available frailty screening methods have insufficient discriminative power to select patients for further assessment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Choosing the optimal method in programmatic colorectal cancer screening: current evidence and controversies

    PubMed Central

    2015-01-01

    Colorectal cancer (CRC) is an important health problem all over the world, being the third most common cancer and the second leading cause of cancer-related death in Western countries. The most important strategy for CRC prevention is screening (i.e. secondary prevention). Since it is widely accepted that adenomas and serrated polyps are the precursors of the vast majority of CRC, early detection and removal of these lesions is associated with a reduction of CRC incidence and, consequently, mortality. Moreover, cancers detected by screening are usually diagnosed at early stages and, therefore, curable by endoscopic or surgical procedures. This review will be address CRC screening strategies in average-risk population, which is defined by those individuals, men and women, 50 years of age or older, without any additional personal or familial predisposing risk factor. In order to maximize the impact of screening and ensure high coverage and equity of access, only organized screening programs (i.e. programmatic screening) should be implemented, as opposed to case-finding or opportunistic screening. For that reason and considering that the optimal approach for colorectal screening may differ depending on the scenario, this review will be focused on the advantages and limitations of each screening strategy in an organized setting. PMID:26136839

  1. A rapid sample screening method for authenticity control of whiskey using capillary electrophoresis with online preconcentration.

    PubMed

    Heller, Melina; Vitali, Luciano; Oliveira, Marcone Augusto Leal; Costa, Ana Carolina O; Micke, Gustavo Amadeu

    2011-07-13

    The present study aimed to develop a methodology using capillary electrophoresis for the determination of sinapaldehyde, syringaldehyde, coniferaldehyde, and vanillin in whiskey samples. The main objective was to obtain a screening method to differentiate authentic samples from seized samples suspected of being false using the phenolic aldehydes as chemical markers. The optimized background electrolyte was composed of 20 mmol L(-1) sodium tetraborate with 10% MeOH at pH 9.3. The study examined two kinds of sample stacking, using a long-end injection mode: normal sample stacking (NSM) and sample stacking with matrix removal (SWMR). In SWMR, the optimized injection time of the samples was 42 s (SWMR42); at this time, no matrix effects were observed. Values of r were >0.99 for the both methods. The LOD and LOQ were better than 100 and 330 mg mL(-1) for NSM and better than 22 and 73 mg L(-1) for SWMR. The CE-UV reliability in the aldehyde analysis in the real sample was compared statistically with LC-MS/MS methodology, and no significant differences were found, with a 95% confidence interval between the methodologies.

  2. Antioxidant activity, total phenolics and flavonoids contents: Should we ban in vitro screening methods?

    PubMed

    Granato, Daniel; Shahidi, Fereidoon; Wrolstad, Ronald; Kilmartin, Paul; Melton, Laurence D; Hidalgo, Francisco J; Miyashita, Kazuo; Camp, John van; Alasalvar, Cesarettin; Ismail, Amin B; Elmore, Stephen; Birch, Gordon G; Charalampopoulos, Dimitris; Astley, Sian B; Pegg, Ronald; Zhou, Peng; Finglas, Paul

    2018-10-30

    As many studies are exploring the association between ingestion of bioactive compounds and decreased risk of non-communicable diseases, the scientific community continues to show considerable interest in these compounds. In addition, as many non-nutrients with putative health benefits are reducing agents, hydrogen donors, singlet oxygen quenchers or metal chelators, measurement of antioxidant activity using in vitro assays has become very popular over recent decades. Measuring concentrations of total phenolics, flavonoids, and other compound (sub)classes using UV/Vis spectrophotometry offers a rapid chemical index, but chromatographic techniques are necessary to establish structure-activity. For bioactive purposes, in vivo models are required or, at the very least, methods that employ distinct mechanisms of action (i.e., single electron transfer, transition metal chelating ability, and hydrogen atom transfer). In this regard, better understanding and application of in vitro screening methods should help design of future research studies on 'bioactive compounds'. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Cost-effectiveness of Colorectal Cancer Screening and Treatment Methods: Mapping of Systematic Reviews.

    PubMed

    Abdolahi, Hossein Mashhadi; Asiabar, Ali Sarabi; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Rezapour, Aziz

    2018-01-01

    Due to extensive literature on colorectal cancer and their heterogeneous results, this study aimed to summarize the systematic reviews which review the cost-effectiveness studies on different aspects of colorectal cancer. The required data were collected by searching the following key words according to MeSH: "colorectal cancer," "colorectal oncology," "colorectal carcinoma," "colorectal neoplasm," "colorectal tumors," "cost-effectiveness," "systematic review," and "meta-analysis." The following databases were searched: PubMed, Cochrane, Google Scholar, and Scopus. Two reviewers evaluated the articles according to the checklist of "assessment of multiple systematic reviews" (AMSTAR) tool. Finally, eight systematic reviews were included in the study. The Drummond checklist was mostly used for assessing the quality of the articles. The main perspective was related to the payer and the least was relevant to the social. The majority of the cases referred to sensitivity analysis (in 76% of the cases) and the lowest point also was allocated to discounting (in 37% of cases). The Markov model was used most widely in the studies. Treatment methods examined in the studies were not cost-effective in comparison with the studied units. Among the screening methods, computerized tomographic colonography and fecal DNA were cost-effective. The average score of the articles' qualities was high (9.8 out of 11). The community perspective should be taken into consideration at large in the studies. It is necessary to pay more attention to discounting subject in studies. More frequent application of the Markov model is recommended.

  4. Spatial screening methods for evaluating environmental contaminant hazards and exposure vulnerability

    NASA Astrophysics Data System (ADS)

    Jones, D. K.

    2016-12-01

    Human and biotic communities are becoming increasingly vulnerable to sea-level rise and severe storms due to climate change. These events enhance the dispersion and concentration of natural and anthropogenic chemicals and pathogenic microorganisms, which could adversely impact the health and resilience of coastal communities and ecosystems in coming years. The U.S. Geological Survey (USGS) has developed spatial screening methods to identify and map contaminant sources and potential exposure pathways for human and ecological receptors. These methods have been applied within the northeastern U.S. to document contaminants of emerging concern, highlight vulnerable communities, and prioritize locations for future sampling campaigns. Integration of this information provides a means to better assess the baseline status of a complex system and the significance of changes in contaminant hazards due to storm-induced (episodic) and sea-level rise (incremental) disturbances. This presentation will provide an overview of a decision support tool developed by the USGS to document contaminants in the environment relative to key receptor populations and historic storm vulnerabilities. The support tool is designed to accommodate a broad array of geologic, land-use, and climatic variables and utilizes public, nationally available data sources to define contaminant sources and storm vulnerabilities. By employing a flexible and adaptable strategy built upon publicly available data, the method can readily be applied to other site selection or landscape evaluation efforts. Examples will be presented including the Sediment-bound Contaminant Resiliency and Response pilot study (see http://toxics.usgs.gov/scorr/), and investigations of endocrine disruption in the Chesapeake Bay. Key limitations and future applications will be discussed in addition to ongoing method developments to accommodate non-coastal disaster scenarios and more refined contaminant definitions.

  5. GC/MS screening method for phthalate esters in children's toys.

    PubMed

    Ting, Keh-Chuh; Gill, Modan; Garbin, Orlando

    2009-01-01

    Phthalate esters are commonly added into polyvinyl chloride (PVC) as softeners to make the plastic material flexible. Phthalates are suspected cancer-causing agents and possible teratogens; they have been linked to liver and kidney damage, as well as the underdevelopment of reproductive organs in humans and animals. Public safety concerns about human exposure to phthalates are on the rise because they do not chemically bond to PVC and leach from the material over time. Following the lead of the European Union and Japan in restricting the use of certain phthalates, a legal limit of 0.1% in children's toys was established by the California State Legislature (AB-1108). In addition to its mission to protect public health and the environment from toxic harm, the California Department of Toxic Substances Control (DTSC) has been delegated the role of lead agency for consumer product safety. To support DTSC's Green Chemistry activities, the Environmental Chemistry Laboratory Mobile Laboratory Team has developed an on-site screening method to monitor phthalates in children's toys. This method is simple, fast, and effective, with ample sensitivity to quantify the 6 restricted phthalates in children's toys at 100 ppm (limit of quantitation = 100 microg/g) which is 10 times lower than the legal allowable level of 0.1%. Additionally, the method has a high throughput capability and enables testing of approximately 6-10 samples per day, depending on the complexity of the sample matrix and concentration. This method is designed to survey the 6 phthalates in children's toys and other consumer products for compliance with the threshold of 0.1% (1000 ppm).

  6. In-Vivo Imaging of Cell Migration Using Contrast Enhanced MRI and SVM Based Post-Processing.

    PubMed

    Weis, Christian; Hess, Andreas; Budinsky, Lubos; Fabry, Ben

    2015-01-01

    The migration of cells within a living organism can be observed with magnetic resonance imaging (MRI) in combination with iron oxide nanoparticles as an intracellular contrast agent. This method, however, suffers from low sensitivity and specificty. Here, we developed a quantitative non-invasive in-vivo cell localization method using contrast enhanced multiparametric MRI and support vector machines (SVM) based post-processing. Imaging phantoms consisting of agarose with compartments containing different concentrations of cancer cells labeled with iron oxide nanoparticles were used to train and evaluate the SVM for cell localization. From the magnitude and phase data acquired with a series of T2*-weighted gradient-echo scans at different echo-times, we extracted features that are characteristic for the presence of superparamagnetic nanoparticles, in particular hyper- and hypointensities, relaxation rates, short-range phase perturbations, and perturbation dynamics. High detection quality was achieved by SVM analysis of the multiparametric feature-space. The in-vivo applicability was validated in animal studies. The SVM detected the presence of iron oxide nanoparticles in the imaging phantoms with high specificity and sensitivity with a detection limit of 30 labeled cells per mm3, corresponding to 19 μM of iron oxide. As proof-of-concept, we applied the method to follow the migration of labeled cancer cells injected in rats. The combination of iron oxide labeled cells, multiparametric MRI and a SVM based post processing provides high spatial resolution, specificity, and sensitivity, and is therefore suitable for non-invasive in-vivo cell detection and cell migration studies over prolonged time periods.

  7. A marine bacterial adhesion microplate test using the DAPI fluorescent dye: a new method to screen antifouling agents.

    PubMed

    Leroy, C; Delbarre-Ladrat, C; Ghillebaert, F; Rochet, M J; Compère, C; Combes, D

    2007-04-01

    To develop a method to screen antifouling agents against marine bacterial adhesion as a sensitive, rapid and quantitative microplate fluorescent test. Our experimental method is based on a natural biofilm formed by mono-incubation of the marine bacterium Pseudoalteromonas sp. D41 in sterile natural sea water in a 96-well polystyrene microplate. The 4'6-diamidino-2-phenylindole dye was used to quantify adhered bacteria in each well. The total measured fluorescence in the wells was correlated with the amount of bacteria showing a detection limit of one bacterium per 5 microm(2) and quantifying 2 x 10(7) to 2 x 10(8) bacteria adhered per cm(2). The antifouling properties of three commercial surface-active agents and chlorine were tested by this method in the prevention of adhesion and also in the detachment of already adhered bacteria. The marine bacterial adhesion inhibition rate depending on the agent concentration showed a sigmoid shaped dose-response curve. This test is well adapted for a rapid and quantitative first screening of antifouling agents directly in seawater in the early steps of marine biofilm formation. In contrast to the usual screenings of antifouling products which detect a bactericidal activity, this test is more appropriate to screen antifouling agents for bacterial adhesion removal or bacterial adhesion inhibition activities. This screening test focuses on the antifouling properties of the products, especially the initial steps of marine biofilm formation.

  8. Optically Based Rapid Screening Method for Proven Optimal Treatment Strategies Before Treatment Begins

    DTIC Science & Technology

    to rapidly test /screen breast cancer therapeutics as a strategy to streamline drug development and provide individualized treatment. The results...system can therefore be used to streamline pre-clinical drug development, by reducing the number of animals , cost, and time required to screen new drugs

  9. School-Based BMI and Body Composition Screening and Parent Notification in California: Methods and Messages

    ERIC Educational Resources Information Center

    Madsen, Kristine A.; Linchey, Jennifer

    2012-01-01

    Background: School-based body mass index (BMI) or body composition screening is increasing, but little is known about the process of parent notification. Since 2001, California has required annual screening of body composition via the FITNESSGRAM, with optional notification. This study sought to identify the prevalence of parental notification…

  10. Robust statistical methods for hit selection in RNA interference high-throughput screening experiments.

    PubMed

    Zhang, Xiaohua Douglas; Yang, Xiting Cindy; Chung, Namjin; Gates, Adam; Stec, Erica; Kunapuli, Priya; Holder, Dan J; Ferrer, Marc; Espeseth, Amy S

    2006-04-01

    RNA interference (RNAi) high-throughput screening (HTS) experiments carried out using large (>5000 short interfering [si]RNA) libraries generate a huge amount of data. In order to use these data to identify the most effective siRNAs tested, it is critical to adopt and develop appropriate statistical methods. To address the questions in hit selection of RNAi HTS, we proposed a quartile-based method which is robust to outliers, true hits and nonsymmetrical data. We compared it with the more traditional tests, mean +/- k standard deviation (SD) and median +/- 3 median of absolute deviation (MAD). The results suggested that the quartile-based method selected more hits than mean +/- k SD under the same preset error rate. The number of hits selected by median +/- k MAD was close to that by the quartile-based method. Further analysis suggested that the quartile-based method had the greatest power in detecting true hits, especially weak or moderate true hits. Our investigation also suggested that platewise analysis (determining effective siRNAs on a plate-by-plate basis) can adjust for systematic errors in different plates, while an experimentwise analysis, in which effective siRNAs are identified in an analysis of the entire experiment, cannot. However, experimentwise analysis may detect a cluster of true positive hits placed together in one or several plates, while platewise analysis may not. To display hit selection results, we designed a specific figure called a plate-well series plot. We thus suggest the following strategy for hit selection in RNAi HTS experiments. First, choose the quartile-based method, or median +/- k MAD, for identifying effective siRNAs. Second, perform the chosen method experimentwise on transformed/normalized data, such as percentage inhibition, to check the possibility of hit clusters. If a cluster of selected hits are observed, repeat the analysis based on untransformed data to determine whether the cluster is due to an artifact in the data

  11. Current and emerging screening methods to identify post-head-emergence frost adaptation in wheat and barley.

    PubMed

    Frederiks, T M; Christopher, J T; Harvey, G L; Sutherland, M W; Borrell, A K

    2012-09-01

    Cereal crops can suffer substantial damage if frosts occur at heading. Identification of post-head-emergence frost (PHEF) resistance in cereals poses a number of unique and difficult challenges. Many decades of research have failed to identify genotypes with PHEF resistance that could offer economically significant benefit to growers. Research and breeding gains have been limited by the available screening systems. Using traditional frost screening systems, genotypes that escape frost injury in trials due to spatial temperature differences and/or small differences in phenology can be misidentified as resistant. We believe that by improving techniques to minimize frost escapes, such 'false-positive' results can be confidently identified and eliminated. Artificial freezing chambers or manipulated natural frost treatments offer many potential advantages but are not yet at the stage where they can be reliably used for frost screening in breeding programmes. Here we describe the development of a novel photoperiod gradient method (PGM) that facilitates screening of genotypes of different phenology under natural field frosts at matched developmental stages. By identifying frost escapes and increasing the efficiency of field screening, the PGM ensures that research effort can be focused on finding genotypes with improved PHEF resistance. To maximize the likelihood of identifying PHEF resistance, we propose that the PGM form part of an integrated strategy to (i) source germplasm;(ii) facilitate high throughput screening; and (iii) permit detailed validation. PGM may also be useful in other studies where either a range of developmental stages and/or synchronized development are desired.

  12. The effect of in-vivo intravenous administration of sodium meglumine diatrizoate on some haematological parameters.

    PubMed

    Agwu, K K; Mgbor, S; Ogbu, S O I; Okeji, M

    2007-01-01

    To investigate the in-vivo effects of intravenous administration of sodium meglumine diatrizoate on some haematological parameters in a Nigerian population. Blood samples were collected before and one hour after intravenous injection of sodium-meglumine diatrizoate from 50 subjects undergoing intravenous urography examinations who had no history of and laboratory confirmed diseases that may affect haematological parameters. Standard laboratory methods were used to assay the haemoglobin concentration (Hb), packed cell volume (PCV), total white blood cell (WBC) count and differentials and blood film for any morphological changes in the red blood cells (RBC). Comparisons were made between the mean values of these haematological parameters before and one hour post injection using paired t-test for any statistically significant differences. There were statistically significant reductions in the mean values of Hb concentration and the neutrophil count one hour post injection compared with their pretest values (p < 0.05). The lymphocytes were also significantly increased post injection compared to the pretest values whereas 70% of the erythrocytes were morphologically altered from their approximately 100% normocytic shape at pre-test. Intravenous administration of sodium-meglumine diatrizoate causes in-vivo reduction in Hb concentration and neutrophil count in humans as well as poikilocytosis of the erythrocytes. Some of these effects have the potential of triggering or exacerbating crisis in a sickle cell anaemia subject which is endemic in our locality. Caution should therefore be exercised in the choice and administration of radiological contrast agents to sickle cell subjects. Preparations that are iso-osmolar with plasma and have less probability in precipitating crises should be preferred instead.

  13. In-vivo fluorescence lifetime imaging for monitoring the efficacy of the cancer treatment

    PubMed Central

    Ardeshirpour, Yasaman; Chernomordik, Victor; Hassan, Moinuddin; Zielinski, Rafal; Capala, Jacek; Gandjbakhche, Amir

    2015-01-01

    Purpose Advances in tumor biology created a foundation for targeted therapy aimed at inactivation of specific molecular mechanisms responsible for cell malignancy. In this paper, we used in-vivo fluorescence lifetime imaging with HER2 targeted fluorescent probes as an alternative imaging method to investigate the efficacy of targeted therapy with 17-DMAG (an HSP90 inhibitor) on tumors with high expression of HER2 receptors. Experimental Design HER2-specific Affibody, conjugated to Alexafluor 750, was injected into nude mice, bearing HER2-positive tumor xenograft. The fluorescence lifetime was measured before treatment and monitored after the probe injections at 12 hours after the last treatment dose, when the response to the 17-DMAG therapy was the most pronounced as well as a week after the last treatment when the tumors grew back almost to their pre-treatment size. Results Imaging results showed significant difference between the fluorescence lifetimes at the tumor and the contralateral site (~0.13ns) in the control group (before treatment) and 7 days after the last treatment when the tumors grew back to their pretreatment dimensions. However, at the time frame that the treatment had its maximum effect (12 hours after the last treatment) the difference between the fluorescence lifetime at the tumor and contralateral site decreased to 0.03ns. Conclusions The results showed a good correlation between fluorescence lifetime and the efficacy of the treatment. These findings show that in-vivo fluorescence lifetime imaging can be used as a promising molecular imaging tool for monitoring the treatment outcome in preclinical models and potentially in patients. PMID:24671949

  14. The Importance of Context in Screening in Occupational Health Interventions in Organizations: A Mixed Methods Study.

    PubMed

    Vignoli, Michela; Nielsen, Karina; Guglielmi, Dina; Tabanelli, Maria C; Violante, Francesco S

    2017-01-01

    In occupational health interventions, there is a debate as to whether standardized or tailored measures should be used to identify which aspects of the psychosocial work environment should be targeted in order to improve employees' well-being. Using the Job Demands-Resources model, the main aim of the present study is to demonstrate how a mixed methods approach to conducting screening enables the identification of potential context-dependent demands and resources in the workplace, which should to be targeted by the intervention. Specifically, we used a mixed methods exploratory sequential research design. First, we conducted four focus groups ( N = 37) in a sample of employees working in grocery stores in Italy. The qualitative results allowed to identify one possible context-specific job demand: the use of a work scheduling IT software, whose implementation resulted in a high rotation between different market's departments. From the qualitative results, this context-specific demand seemed to be related to workers' well-being. Thus, in a subsequent questionnaire survey ( N = 288), we included this demand together with generic measures of social support and psychological well-being. Results confirmed that this context-specific job demand was related to emotional exhaustion. Furthermore, it was found that social support moderated the relationship between this specific job demand and emotional exhaustion showing among employees whose activities depended on the IT software, employees that perceived higher levels of social support from colleagues experienced lower levels of emotional exhaustion with respect to their colleagues who perceived lower levels of social support. The present study confirms that mixed methods approach is useful in occupational health intervention research and offers a way forward on helping organizations prioritize their intervention activities.

  15. A Droplet Digital PCR Method for Severe Combined Immunodeficiency Newborn Screening.

    PubMed

    Vidal-Folch, Noemi; Milosevic, Dragana; Majumdar, Ramanath; Gavrilov, Dimitar; Matern, Dietrich; Raymond, Kimiyo; Rinaldo, Piero; Tortorelli, Silvia; Abraham, Roshini S; Oglesbee, Devin

    2017-09-01

    Severe combined immunodeficiency (SCID) benefits from early intervention via hematopoietic cell transplantation to reverse T-cell lymphopenia (TCL). Newborn screening (NBS) programs use T-cell receptor excision circle (TREC) levels to detect SCID. Real-time quantitative PCR is often performed to quantify TRECs in dried blood spots (DBSs) for NBS. Yet, real-time quantitative PCR has inefficiencies necessitating normalization, repeat analyses, or standard curves. To address these issues, we developed a multiplex, droplet digital PCR (ddPCR) method for measuring absolute TREC amounts in one DBS punch. TREC and RPP30 levels were simultaneously measured with a Bio-Rad AutoDG and QX200 ddPCR system. DBSs from 610 presumed-normal, 29 lymphocyte-profiled, and 10 clinically diagnosed infants (1 X-linked SCID, 1 RAG1 Omenn syndrome, and other conditions) were tested. Control infants showed 14 to 474 TREC copies/μL blood. SCID infants, and other TCL conditions, had ≤15 TREC copies/μL. The ddPCR lower limit of quantitation was 14 TREC copies/μL, and the limit of detection was 4 TREC copies/μL. Intra-assay and interassay imprecision was <20% CV for DBSs at 54 to 60 TREC copies/μL. Testing 29 infants with known lymphocyte profiles resulted in a sensitivity of 88.9% and a specificity of 100% at TRECs <20 copies/μL. We developed a multiplex ddPCR method for the absolute quantitation of DBS TRECs that can detect SCID and other TCL conditions associated with absent or low TRECs and validated this method for NBS. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  16. The Importance of Context in Screening in Occupational Health Interventions in Organizations: A Mixed Methods Study

    PubMed Central

    Vignoli, Michela; Nielsen, Karina; Guglielmi, Dina; Tabanelli, Maria C.; Violante, Francesco S.

    2017-01-01

    In occupational health interventions, there is a debate as to whether standardized or tailored measures should be used to identify which aspects of the psychosocial work environment should be targeted in order to improve employees’ well-being. Using the Job Demands-Resources model, the main aim of the present study is to demonstrate how a mixed methods approach to conducting screening enables the identification of potential context-dependent demands and resources in the workplace, which should to be targeted by the intervention. Specifically, we used a mixed methods exploratory sequential research design. First, we conducted four focus groups (N = 37) in a sample of employees working in grocery stores in Italy. The qualitative results allowed to identify one possible context-specific job demand: the use of a work scheduling IT software, whose implementation resulted in a high rotation between different market’s departments. From the qualitative results, this context-specific demand seemed to be related to workers’ well-being. Thus, in a subsequent questionnaire survey (N = 288), we included this demand together with generic measures of social support and psychological well-being. Results confirmed that this context-specific job demand was related to emotional exhaustion. Furthermore, it was found that social support moderated the relationship between this specific job demand and emotional exhaustion showing among employees whose activities depended on the IT software, employees that perceived higher levels of social support from colleagues experienced lower levels of emotional exhaustion with respect to their colleagues who perceived lower levels of social support. The present study confirms that mixed methods approach is useful in occupational health intervention research and offers a way forward on helping organizations prioritize their intervention activities. PMID:28848468

  17. Rapid Screening Method for Detecting Ethinyl Estradiol in Natural Water Employing Voltammetry

    PubMed Central

    2016-01-01

    17α-Ethinyl estradiol (EE2), which is used worldwide in the treatment of some cancers and as a contraceptive, is often found in aquatic systems and is considered a pharmaceutically active compound (PhACs) in the environment. Current methods for the determination of this compound, such as chromatography, are expensive and lengthy and require large amounts of toxic organic solvents. In this work, a voltammetric procedure is developed and validated as a screening tool for detecting EE2 in water samples without prior extraction, clean-up, or derivatization steps. Application of the method we elaborate here to EE2 analysis is unprecedented. EE2 detection was carried out using differential pulse adsorptive cathodic stripping voltammetry (DP AdCSV) with a hanging mercury drop electrode (HMDE) in pH 7.0 Britton-Robinson buffer. The electrochemical process of EE2 reduction was investigated by cyclic voltammetry at different scan rates. Electroreduction of the hormone on a mercury electrode exhibited a peak at −1.16 ± 0.02 V versus Ag/AgCl. The experimental parameters were as follows: −0.7 V accumulation potential, 150 s accumulation time, and 60 mV s−1 scan rate. The limit of detection was 0.49 μg L−1 for a preconcentration time of 150 s. Relative standard deviations were less than 13%. The method was applied to the detection of EE2 in water samples with recoveries ranging from 93.7 to 102.5%. PMID:27738548

  18. Cost-effectiveness of Colorectal Cancer Screening and Treatment Methods: Mapping of Systematic Reviews

    PubMed Central

    Abdolahi, Hossein Mashhadi; Asiabar, Ali Sarabi; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Rezapour, Aziz

    2018-01-01

    Objective: Due to extensive literature on colorectal cancer and their heterogeneous results, this study aimed to summarize the systematic reviews which review the cost-effectiveness studies on different aspects of colorectal cancer. Methods: The required data were collected by searching the following key words according to MeSH: “colorectal cancer,” “colorectal oncology,” “colorectal carcinoma,” “colorectal neoplasm,” “colorectal tumors,” “cost-effectiveness,” “systematic review,” and “meta-analysis.” The following databases were searched: PubMed, Cochrane, Google Scholar, and Scopus. Two reviewers evaluated the articles according to the checklist of “assessment of multiple systematic reviews” (AMSTAR) tool. Results: Finally, eight systematic reviews were included in the study. The Drummond checklist was mostly used for assessing the quality of the articles. The main perspective was related to the payer and the least was relevant to the social. The majority of the cases referred to sensitivity analysis (in 76% of the cases) and the lowest point also was allocated to discounting (in 37% of cases). The Markov model was used most widely in the studies. Treatment methods examined in the studies were not cost-effective in comparison with the studied units. Among the screening methods, computerized tomographic colonography and fecal DNA were cost-effective. The average score of the articles’ qualities was high (9.8 out of 11). Conclusions: The community perspective should be taken into consideration at large in the studies. It is necessary to pay more attention to discounting subject in studies. More frequent application of the Markov model is recommended. PMID:29379836

  19. Noninvasive Assessment of Excessive Erythrocytosis as a Screening Method for Chronic Mountain Sickness at High Altitude

    PubMed Central

    Vyas, Kaetan J.; Danz, David; Gilman, Robert H.; Wise, Robert A.; León-Velarde, Fabiola; Jaime Miranda, J.

    2015-01-01

    Abstract Vyas, Kaetan J., David Danz, Robert H. Gilman, Robert A. Wise, Fabiola León-Velarde, J. Jaime Miranda, and William Checkley. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt Med Biol 16:162–168, 2015.—Globally, over 140 million people are at risk of developing chronic mountain sickness, a common maladaptation to life at high altitude (>2500 meters above sea level). The diagnosis is contingent upon the identification of excessive erythrocytosis (EE). Current best practices to identify EE require a venous blood draw, which is cumbersome for large-scale surveillance. We evaluated two point-of-care biomarkers to screen for EE: noninvasive spot-check tests of total hemoglobin and oxyhemoglobin saturation (Pronto-7, Masimo Corporation). We conducted paired evaluations of total serum hemoglobin from a venous blood draw and noninvasive, spot-check testing of total hemoglobin and oxyhemoglobin saturation with the Pronto-7 in 382 adults aged ≥35 years living in Puno, Peru (3825 meters above sea level). We used the Bland-Altman method to measure agreement between the noninvasive hemoglobin assessment and the gold standard lab hemoglobin analyzer. Mean age was 58.8 years and 47% were male. The Pronto-7 test was unsuccessful in 21 (5%) participants. Limits of agreement between total hemoglobin measured via venous blood draw and the noninvasive, spot-check test ranged from −2.8 g/dL (95% CI −3.0 to −2.5) to 2.5 g/dL (95% CI 2.2 to 2.7), with a bias of −0.2 g/dL (95% CI −0.3 to −0.02) for the difference between total hemoglobin and noninvasive hemoglobin concentrations. Overall, the noninvasive spot-check test of total hemoglobin had a better area under the receiver operating characteristic curve compared to oxyhemoglobin saturation for the identification of EE as measured by a gold standard laboratory hemoglobin analyzer (0.96 vs. 0.82; p<0.001). Best cut-off values

  20. Provision of information about newborn screening antenatally: a sequential exploratory mixed-methods project.

    PubMed

    Ulph, Fiona; Wright, Stuart; Dharni, Nimarta; Payne, Katherine; Bennett, Rebecca; Roberts, Stephen; Walshe, Kieran; Lavender, Tina

    2017-10-01

    Participation in the UK Newborn Bloodspot Screening Programme (NBSP) requires parental consent but concerns exist about whether or not this happens in practice and the best methods and timing to obtain consent at reasonable cost. To collate all possible modes of prescreening communication and consent for newborn (neonatal) screening (NBS); examine midwives', screening professionals' and users' views about the feasibility, efficiency and impact on understanding of each; measure midwives' and parents' preferences for information provision; and identify key drivers of cost-effectiveness for alternative modes of information provision. Six study designs were used: (1) realist review - to generate alternative communication and consent models; (2) qualitative interviews with parents and health professionals - to examine the implications of current practice for understanding and views on alternative models; (3) survey and observation of midwives - to establish current costs; (4) stated preference surveys with midwives, parents and potential future parents - to establish preferences for information provision; (5) economic analysis - to identify cost-effectiveness drivers of alternative models; and (6) stakeholder validation focus groups and interviews - to examine the acceptability, views and broader impact of alternative communication and consent models. Providers and users of NBS in England. Study 2: 45 parents and 37 health professionals; study 3: 22 midwives and eight observations; study 4: 705 adults aged 18-45 years and 134 midwives; and study 6: 12 health-care professionals and five parents. The realist review identified low parental knowledge and evidence of coercive consent practices. Interview, focus group and stated preference data suggested a preference for full information, with some valuing this more than choice. Health professionals preferred informed choice models but parents and health professionals queried whether or not current consent was fully informed

  1. Evaluation of a Rapid Method for Screening Heat Stress Tolerance Using Three Korean Wheat (Triticum aestivum L.) Cultivars.

    PubMed

    Truong, Hai An; Jeong, Chan Young; Lee, Won Je; Lee, Byung Cheon; Chung, Namhyun; Kang, Chon-Sik; Cheong, Young-Keun; Hong, Suk-Whan; Lee, Hojoung

    2017-07-19

    Thermotolerance in plants is a topic of concern given the current trends in global warming. Here, we aimed to develop a rapid and reproducible screening method for selection of heat stress-tolerant wheat varieties to expedite the breeding process. We tested the robustness of the screen in three Korean wheat cultivars, "BackJung", "KeumKang", and "ChoKyeong". We showed that 4-day-old seedlings of "KeumKang" had the highest survival rates after a 45 °C treatment for 20 h. Moreover, the ability to retain chlorophyll and antioxidant activity was also highest in "KeumKang". The increase in malondialdehyde content in "ChoKyeong" indicated that this cultivar showed the greatest damage after heat stress. Collectively, our results showed that "KeumKang" is the most heat-tolerant cultivar of the three examined. In conclusion, the most reliable and rapid screening method in our investigation was survival rate examined at lethal temperature.

  2. aSi EPIDs for the in-vivo dosimetry of static and dynamic beams

    NASA Astrophysics Data System (ADS)

    Piermattei, A.; Cilla, S.; Azario, L.; Greco, F.; Russo, M.; Grusio, M.; Orlandini, L.; Fidanzio, A.

    2015-10-01

    Portal imaging by amorphous silicon (aSi) photodiode is currently the most applied technology for in-vivo dosimetry (IVD) of static and dynamic radiotherapy beams. The strategy, adopted in this work to perform the IVD procedure by aSi EPID, is based on: in patient reconstruction of the isocenter dose and day to day comparison between 2D-portal images to verify the reproducibility of treatment delivery. About 20.000 tests have been carried out in this last 3 years in 8 radiotherapy centers using the SOFTDISO program. The IVD results show that: (i) the procedure can be implemented for linacs of different manufacturer, (ii) the IVD analysis can be obtained on a computer screen, in quasi real time (about 2 min after the treatment delivery) and (iii) once the causes of the discrepancies were eliminated, all the global IVD tests for single patient were within the acceptance criteria defined by: ±5% for the isocenter dose, and Pγ<1≥90% of the checked points for the 2D portal image γ-analysis. This work is the result of a project supported by the Istituto Nazionale di Fisica Nucleare (INFN) and Università Cattolica del S.Cuore (UCSC).

  3. Screening method for detection of immediate amino acid decarboxylases--producing bacteria implicated in food poisoning.

    PubMed

    Hussain, Husniza; Mohd Fuat, A R; Vimala, B; Ghazali, H M

    2011-08-01

    Assessment of amino acid decarboxylase activity can be conducted using tubed broth or plated agar. In this study, the test was carried out in microtitre plates containing lysine, ornithine, arginine, tyrosine, tryptophan, phenylalanine or histidine as biogenic amine precursors. Møller decarboxylase base broth (MDB) with or without 1% of a known amino acid were added to wells of a 96 well-microtitre plate. The wells were inoculated with Escherichia coli, Klebsiella pneumoniae, Acinetobacter anitratus or Staphylococcus aureus to the final concentration of 6.0 x 10(7) cfu/ml and incubated at 35ºC. The absorbance of the culture broth was read at 570 nm at 0, 1.0, 2.0, 3.0, 4.0, 5.5, 6.5 and 7.5 hour. Comparison of means of A'(570) between 0 hour and a specified incubation time was determined statistically. Positive decarboxylase activities were detected in the media inoculated with E. coli and K. pneumoniae in less than 6 hours. The current method is suitable for immediate producers of amino acid decarboxylase enzymes. It costs less as it uses less amino acid and it has the potential to be used for screening aliquots of food materials for amino acid decarboxylase activities.

  4. Development of RNAi method for screening candidate genes to control emerald ash borer, Agrilus planipennis.

    PubMed

    Rodrigues, Thais B; Rieske, Lynne K; J Duan, Jian; Mogilicherla, Kanakachari; Palli, Subba R

    2017-08-07

    The ingestion of double-strand RNAs (dsRNA) targeting essential genes in an insect could cause mortality. Based on this principle, a new generation of insect control methods using RNA interference (RNAi) are being developed. In this work, we developed a bioassay for oral delivery of dsRNA to an invasive forest and urban tree pest, the emerald ash borer (EAB, Agrilus planipennis). EAB feeds and develops beneath the bark, killing trees rapidly. This behavior, coupled with the lack of a reliable artificial diet for rearing larvae and adults, make them difficult to study. We found that dsRNA is transported and processed to siRNAs by EAB larvae within 72 h after ingestion. Also, feeding neonate larvae with IAP (inhibitor of apoptosis) or COP (COPI coatomer, β subunit) dsRNA silenced their target genes and caused mortality. Both an increase in the concentration of dsRNA fed and sequential feeding of two different dsRNAs increased mortality. Here we provide evidence for successful RNAi in EAB, and demonstrate the development of a rapid and effective bioassay for oral delivery of dsRNA to screen additional genes.

  5. Photoionization study of the F2+ ion via the screening constant by unit nuclear charge method

    NASA Astrophysics Data System (ADS)

    Dieng, M.; Tine, M.; Sow, M.; Diop, B.; Guèye, M.; Faye, M.; Sakho, I.; Biaye, M.; Wagué, A.

    2014-03-01

    In this paper, we have tabulated energy resonances of the 2s22p2 (1D)nd (2L), 2s22p2 (1S)nd (2L) and 2s22p3 (3D)np Rydberg series originating from the 2s22p3(2Po) and from the 2s22p3 (2Do) metastable states of F2+. In addition, energy resonances of the 2s2p3(5So)np (4P) Rydberg series originating from the 2s22p3 (4So) ground-state of F2+are also reported. Calculations are performed using the Screening constant by unit nuclear charge (SCUNC) method. Analysis of the present data is achieved by calculating the quantum defects and the effective nuclear charges for each series. The present results agree very well with the Advanced Light Source experiments on F2+ (Aguilar et al., 2005). Upto n=30, the present quantum defects are almost constant and the effective charge decreases regularly toward the electric charge of the F3+ core ion along each series.

  6. Device and method for screening crystallization conditions in solution crystal growth

    NASA Technical Reports Server (NTRS)

    Carter, Daniel C. (Inventor)

    1995-01-01

    A device and method for detecting optimum protein crystallization conditions and for growing protein crystals in either 1g or microgravity environments comprising a housing, defining at least one pair of chambers for containing crystallization solutions is presented. The housing further defines an orifice therein for providing fluid communication between the chambers. The orifice is adapted to receive a tube which contains a gelling substance for limiting the rate of diffusive mixing of the crystallization solutions. The solutions are diffusively mixed over a period of time defined by the quantity of gelling substance sufficient to achieve equilibration and to substantially reduce density driven convection disturbances therein. The device further includes endcaps to seal the first and second chambers. One of the endcaps includes a dialysis chamber which contains protein solution in which protein crystals are grown. Once the endcaps are in place, the protein solution is exposed to the crystallization solutions wherein the solubility of the protein solution is reduced at a rate responsive to the rate of diffusive mixing of the crystallization solutions. This allows for a controlled approach to supersaturation and allows for screening of crystal growth conditions at preselected intervals.

  7. Device and Method for Screening Crystallization Conditions in Solution Crystal Growth

    NASA Technical Reports Server (NTRS)

    Carter, Daniel C. (Inventor)

    1997-01-01

    A device and method for detecting optimum protein crystallization conditions and for growing protein crystals in either 1 g or microgravity environments comprising a housing defining at least one pair of chambers for containing crystallization solutions. The housing further defines an orifice therein for providing fluid communication between the chambers. The orifice is adapted to receive a tube which contains a gelling substance for limiting the rate of diffusive mixing of the crystallization solutions. The solutions are diffusively mixed over a period of time defined by the quantity of gelling substance sufficient to achieve equilibration and to substantially reduce density driven convection disturbances therein. The device further includes endcaps to seal the first and second chambers. One of the endcaps includes a dialysis chamber which contains protein solution in which protein crystals are grown. Once the endcaps are in place. the protein solution is exposed to the crystallization solutions wherein the solubility of the protein solution is reduced at a rate responsive to the rate of diffusive mixing of the crystallization solutions. This allows for a controlled approach to supersaturation and allows for screening of crystal growth conditions at preselected intervals.

  8. Robust high-throughput batch screening method in 384-well format with optical in-line resin quantification.

    PubMed

    Kittelmann, Jörg; Ottens, Marcel; Hubbuch, Jürgen

    2015-04-15

    High-throughput batch screening technologies have become an important tool in downstream process development. Although continuative miniaturization saves time and sample consumption, there is yet no screening process described in the 384-well microplate format. Several processes are established in the 96-well dimension to investigate protein-adsorbent interactions, utilizing between 6.8 and 50 μL resin per well. However, as sample consumption scales with resin volumes and throughput scales with experiments per microplate, they are limited in costs and saved time. In this work, a new method for in-well resin quantification by optical means, applicable in the 384-well format, and resin volumes as small as 0.1 μL is introduced. A HTS batch isotherm process is described, utilizing this new method in combination with optical sample volume quantification for screening of isotherm parameters in 384-well microplates. Results are qualified by confidence bounds determined by bootstrap analysis and a comprehensive Monte Carlo study of error propagation. This new approach opens the door to a variety of screening processes in the 384-well format on HTS stations, higher quality screening data and an increase in throughput. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Estimation of effectiveness of interventions for malaria control in pregnancy using the screening method.

    PubMed

    Msyamboza, K; Senga, E; Tetteh-Ashong, E; Kazembe, P; Brabin, B J

    2007-04-01

    The evaluation of the effectiveness of antimalarial drugs and bed net use in pregnant women is an important aspect of monitoring and surveillance of malaria control in pregnancy. In principle the screening method for assessing vaccine efficacy can be applied in non-vaccine settings for assessing interventions for malaria control in pregnancy. In this analysis field data on the proportion of placental malaria cases treated with two doses of sulphadoxine-pyrimethamine (SP) and the uptake of two doses of SP in the antenatal clinic was used in a case-coverage method to assess the protective effectiveness (PE) of intermittent preventive treatment with SP for malaria control in pregnancy. PE was assessed using placental malaria, low birthweight and maternal anaemia at delivery as outcome variables. The method was also applied to an evaluation of the protective effectiveness of self-reported use of impregnated bed nets (ITNs). Effectiveness was highest for reduction of low birthweight in multigravidae (87.2%, 95% CI, 83.2-91.3%). PE was lower for placental malaria (61.6% primigravidae, 28.5% multigravidae), and maternal anaemia (Hb < 8.0 g/dl, 37.8% primigravidae, 29.6% multigravidae). Estimates for PE of self-reported use of ITNs gave values for all three outcome parameters that were much lower than for SP use. For women of all parties effectiveness estimates for reduction of low birthweight were 22% (95% CI, 17.7-26.4), prevention of placental malaria (all types) 7.1% (95% CI, 4.4-9.8), prevention of active placental infection 38.9% (95% CI, 27.4-50.4), and for maternal anaemia 8.8% (95% CI, 0-20.0). The case-coverage method could provide a useful and practical approach to routine monitoring and evaluation of drug interventions to control malaria in pregnancy and has potentially wide applications. Effectiveness estimates related to reported ITN use in pregnancy may be less reliable. The method should be further evaluated using currently available data sets.

  10. A Simple Method for High Throughput Chemical Screening in Caenorhabditis Elegans

    PubMed Central

    Lucanic, Mark; Garrett, Theo; Gill, Matthew S.; Lithgow, Gordon J.

    2018-01-01

    Caenorhabditis elegans is a useful organism for testing chemical effects on physiology. Whole organism small molecule screens offer significant advantages for identifying biologically active chemical structures that can modify complex phenotypes such as lifespan. Described here is a simple protocol for producing hundreds of 96-well culture plates with fairly consistent numbers of C. elegans in each well. Next, we specified how to use these cultures to screen thousands of chemicals for effects on the lifespan of the nematode C. elegans. This protocol makes use of temperature sensitive sterile strains, agar plate conditions, and simple animal handling to facilitate the rapid and high throughput production of synchronized animal cultures for screening. PMID:29630057

  11. Breast cancer amelioration by Butea monosperma in-vitro and in-vivo.

    PubMed

    Karia, Prachi; Patel, Kirti V; Rathod, Shri S P

    2018-05-10

    Butea monosperma belonging to family Fabaceae is used in the Indian traditional medicine (Ayurveda) for various ailments including abdominal tumors and possess anti-estrogenic activity. The present study is aimed at investigating the chemo-preventive potential of Butea monosperma in breast cancer and elucidating it's mechanism of action by assessing its effect on key processes like apoptosis, angiogenesis and metastasis. Cytotoxic potential of methanol extract of Butea monosperma flower (MEBM) was tested in MCF-7 (estrogen receptor positive), MDA-MB-231 (triple negative) and MDA-MB-453 (HER2 positive) human breast cancer cells by MTT assay. Chemo-preventive potential was evaluated in-vivo in Methylnitrosourea (MNU) induced mammary cancer in nulliparous Sprague-Dawley rats. The mechanism for anticancer potential was screened by in-vitro studies involving Annexin V- FITC assay (apoptosis), Chick Chorioallantoic Membrane assay (angiogenesis) and Migration assay (metastasis). Statistical analysis was done by one way and two way ANOVA (for Growth Rate and feed consumption efficiency) followed by post hoc Bonferroni's test with P value < 0.05. It is observed that the exposure of MEBM, at various concentrations and time intervals to different cell lines, resulted in decreased cell proliferation. The IC 50 value of MCF-7 cells was found significantly less than that of MDA-MB-231 and MDA-MB-453 cells, which indicated that the extract of said medicinal plant were more potent inhibitors of estrogen positive breast cancer cells than other types of breast cancer cells in vitro. Corroborative evidences were acquired in MNU actuated mammary carcinogenesis where MEBM constricted tumor parameters, decreased expression of estrogen and progesterone, nucleic acid content and increased latency period. MEBM also induced apoptosis, inhibited angiogenesis and metastasis in-vitro. Selective cytotoxic activity in MCF-7 estrogen positive breast cancer cells and inhibition of growth of

  12. Phene Plate (PhP) biochemical fingerprinting. A screening method for epidemiological typing of enterococcal isolates.

    PubMed

    Saeedi, B; Tärnberg, M; Gill, H; Hällgren, A; Jonasson, J; Nilsson, L E; Isaksson, B; Kühn, I; Hanberger, H

    2005-09-01

    Pulsed-field gel electrophoresis (PFGE) is currently considered the gold standard for genotyping of enterococci. However, PFGE is both expensive and time-consuming. The purpose of this study was to investigate whether the PhP system can be used as a reliable clinical screening method for detection of genetically related isolates of enterococci. If so, it should be possible to minimize the number of isolates subjected to PFGE typing, which would save time and money. Ninety-nine clinical enterococcal isolates were analysed by PhP (similarity levels 0.90-0.975) and PFGE (similarity levels < or =3 and < or =6 bands) and all possible pairs of isolates were cross-classified as matched or mismatched. We found that the probability that a pair of isolates (A and B) belonging to the same type according to PhP also belong to the same cluster according to PFGE, i.e. p(A(PFGE)=B(PFGE) * A(PhP)=B(PhP)), and the probability that a pair of isolates of different types according to PhP also belong to different clusters according to PFGE, i.e. p(A(PFGE) not equalB(PFGE) * A(PhP) not equalB(PhP)), was relatively high for E. faecalis (0.86 and 0.96, respectively), but was lower for E. faecium (0.51 and 0.77, respectively). The concordance which shows the probability that PhP and PFGE agree on match or mismatch was 86%-93% for E. faecalis and 54%-66% for E. faecium, which indicates that the PhP method may be useful for epidemiological typing of E. faecalis in the current settings but not for E. faecium.

  13. A simple phenotypic method for screening of MCR-1-mediated colistin resistance.

    PubMed

    Coppi, M; Cannatelli, A; Antonelli, A; Baccani, I; Di Pilato, V; Sennati, S; Giani, T; Rossolini, G M

    2018-02-01

    To evaluate a novel method, the colistin-MAC test, for phenotypic screening of acquired colistin resistance mediated by transferable mcr-1 resistance determinants, based on colistin MIC reduction in the presence of dipicolinic acid (DPA). The colistin-MAC test consists in a broth microdilution method, in which colistin MIC is tested in the absence or presence of DPA (900 μg/mL). Overall, 74 colistin-resistant strains of Enterobacteriaceae (65 Escherichia coli and nine other species), including 61 strains carrying mcr-1-like genes and 13 strains negative for mcr genes, were evaluated with the colistin-MAC test. The presence of mcr-1-like and mcr-2-like genes was assessed by real-time PCR and end-point PCR. For 20 strains, whole-genome sequencing data were also available. A ≥8-fold reduction of colistin MIC in the presence of DPA was observed with 59 mcr-1-positive strains, including 53 E. coli of clinical origin, three E. coli transconjugants carrying MCR-1-encoding plasmids, one Enterobacter cloacae complex and two Citrobacter spp. Colistin MICs were unchanged, increased or at most reduced by twofold with the 13 mcr-negative colistin-resistant strains (nine E. coli and four Klebsiella pneumoniae), but also with two mcr-1-like-positive K. pneumoniae strains. The colistin-MAC test could be a simple phenotypic test for presumptive identification of mcr-1-positive strains among isolates of colistin-resistant E. coli, based on a ≥8-fold reduction of colistin MIC in the presence of DPA. Evaluation of the test with a larger number of strains, species and mcr-type resistance determinants would be of interest. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Determination of Tolerance to Internal Shorts and Its Screening in Lithium-ion Cells NASA - JSC Method

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith

    2009-01-01

    This slide presentation reviews the method developed by the NASA Johnson Space Center (JSC) to determine tolerances to internal shorts and screening for problems in commercial off the shelf (COTS) Lithium-ion batteries. The test apparatus is shown and several examples of the usage and results of the test are discussed.

  15. Assessment of Knowledge of Breast Cancer and Screening Methods among Nurses in University Hospitals in Addis Ababa, Ethiopia, 2011

    PubMed Central

    Lemlem, Semarya Berhe; Sinishaw, Worknish; Hailu, Mignote; Abebe, Mesfin; Aregay, Alemseged

    2013-01-01

    Background. According to the American Cancer Society, about 1.3 million women will be diagnosed with breast cancer annually worldwide and about 465,000 will die from the disease. In Ethiopia breast cancer is the second most often occurring cancer among women. Early diagnosis is especially important for breast cancer because the disease responds best to treatment before it has spread. Objective. To assess knowledge of breast cancer and screening methods among nurses in university hospitals. Method. This cross-sectional descriptive study used simple random sampling on sample of 281 nurses. Structured questionnaires draw out responses about knowledge and screening method of nurses in regard to breast cancer. Bivariate analysis was used principally and variables were then entered to multiple logistic regressions model for controlling the possible effect of confounders and the variables which have significant association were identified on the basis of OR, with 95% CI and P value. Results. The findings of this study revealed that only 156 (57.8%) of them were knowledgeable about breast cancer and its screening and 114 (42.2%) were not. Knowledge of breast cancer was found to be significantly associated with regular course in nursing, family history of respondents, and unit of work. Conclusion and Recommendation. The results of this study indicate that the knowledge of nurses is not satisfying and highlight the need to improve the content in the nursing curriculum and to undergo more workplace training in the area of breast cancer and screening methods. PMID:23986873

  16. Development of a Novel Screening Method for the Isolation of “Cronobacter” spp. (Enterobacter sakazakii)▿

    PubMed Central

    Iversen, Carol; Druggan, Patrick; Schumacher, Sandra; Lehner, Angelika; Feer, Claudia; Gschwend, Karl; Joosten, Han; Stephan, Roger

    2008-01-01

    A differential medium, “Cronobacter” screening broth, has been designed to complement agars based on hydrolysis of chromogenic α-glucopyranoside substrates. The broth was evaluated using 329 Enterobacteriaceae strains (229 target isolates), spiked/naturally contaminated samples, and a parallel comparison with current methods for raw materials, line/end products, and factory environment samples. PMID:18310415

  17. Multi-spectral confocal microendoscope for in-vivo imaging

    NASA Astrophysics Data System (ADS)

    Rouse, Andrew Robert

    The concept of in-vivo multi-spectral confocal microscopy is introduced. A slit-scanning multi-spectral confocal microendoscope (MCME) was built to demonstrate the technique. The MCME employs a flexible fiber-optic catheter coupled to a custom built slit-scan confocal microscope fitted with a custom built imaging spectrometer. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The design and performance of the miniature objective and focus assembly are discussed. The 3mm diameter catheter may be used on its own or routed though the instrument channel of a commercial endoscope. The confocal nature of the system provides optical sectioning with 3mum lateral resolution and 30mum axial resolution. The prism based multi-spectral detection assembly is typically configured to collect 30 spectral samples over the visible chromatic range. The spectral sampling rate varies from 4nm/pixel at 490nm to 8nm/pixel at 660nm and the minimum resolvable wavelength difference varies from 7nm to 18nm over the same spectral range. Each of these characteristics are primarily dictated by the dispersive power of the prism. The MCME is designed to examine cellular structures during optical biopsy and to exploit the diagnostic information contained within the spectral domain. The primary applications for the system include diagnosis of disease in the gastro-intestinal tract and female reproductive system. Recent data from the grayscale imaging mode are presented. Preliminary multi-spectral results from phantoms, cell cultures, and excised human tissue are presented to demonstrate the potential of in-vivo multi-spectral imaging.

  18. Toward a systems-level analysis of infection biology: a new method for conducting genetic screens in human cells.

    PubMed

    Stanley, Sarah A; Hung, Deborah T

    2009-12-16

    Loss-of-function genetic screens have facilitated great strides in our understanding of the biology of model organisms but have not been possible in diploid human cells. A recent report by Brummelkamp's group in Science describes the use of insertional mutagenesis to generate loss-of-function alleles in a largely haploid human cell line and demonstrates the versatility of this method in screens designed to investigate the host/pathogen interaction. This approach has strengths that are complementary to existing strategies and will facilitate progress toward a systems-level understanding of infectious disease and ultimately the development of new therapeutics.

  19. Development and interlaboratory validation of quantitative polymerase chain reaction method for screening analysis of genetically modified soybeans.

    PubMed

    Takabatake, Reona; Onishi, Mari; Koiwa, Tomohiro; Futo, Satoshi; Minegishi, Yasutaka; Akiyama, Hiroshi; Teshima, Reiko; Kurashima, Takeyo; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2013-01-01

    A novel real-time polymerase chain reaction (PCR)-based quantitative screening method was developed for three genetically modified soybeans: RRS, A2704-12, and MON89788. The 35S promoter (P35S) of cauliflower mosaic virus is introduced into RRS and A2704-12 but not MON89788. We then designed a screening method comprised of the combination of the quantification of P35S and the event-specific quantification of MON89788. The conversion factor (Cf) required to convert the amount of a genetically modified organism (GMO) from a copy number ratio to a weight ratio was determined experimentally. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDR), respectively. The determined RSDR values for the method were less than 25% for both targets. We consider that the developed method would be suitable for the simple detection and approximate quantification of GMO.

  20. Offering fragile X syndrome carrier screening: a prospective mixed-methods observational study comparing carrier screening of pregnant and non-pregnant women in the general population

    PubMed Central

    Martyn, M; Anderson, V; Archibald, A; Carter, R; Cohen, J; Delatycki, M; Donath, S; Emery, J; Halliday, J; Hill, M; Sheffield, L; Slater, H; Tassone, F; Younie, S; Metcalfe, S

    2013-01-01

    Introduction Fragile X syndrome (FXS) is the leading cause of inherited intellectual and developmental disability. Policy development relating to carrier screening programmes for FXS requires input from large studies examining not only test uptake but also psychosocial aspects. This study will compare carrier screening in pregnant and non-pregnant populations, examining informed decision-making, psychosocial issues and health economics. Methods and Analysis Pregnant and non-pregnant women are being recruited from general practices and obstetric services. Women receive study information either in person or through clinic mail outs. Women are provided pretest counselling by a genetic counsellor and make a decision about testing in their own time. Data are being collected from two questionnaires: one completed at the time of making the decision about testing and the second 1 month later. Additional data are gathered through qualitative interviews conducted at several time points with a subset of participating women, including all women with a positive test result, and with staff from recruiting clinics. A minimum sample size of 500 women/group has been calculated to give us 88% power to detect a 10% difference in test uptake and 87% power to detect a 10% difference in informed choice between the pregnant and non-pregnant groups. Questionnaire data will be analysed using descriptive statistics and multivariate logistic regression models. Interview data will be thematically analysed. Willingness-to-pay and cost effectiveness analyses will also be performed. Recruitment started in July 2009 and data collection will be completed by December 2013. Ethics and Dissemination Ethics approval has been granted by the Universities of Melbourne and Western Australia and by recruiting clinics, where required. Results will be reported in peer-reviewed publications, conference presentations and through a website http://www.fragilexscreening.net.au. The results of this study will

  1. Evaluation of a QuECHERS-like extraction approach for the determination of PBDEs in mussels by immuno-assay-based screening methods

    USDA-ARS?s Scientific Manuscript database

    A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. A simple sample preparation in conjunction with a rapid screening method possesses the desired c...

  2. Development of a cloud-screening method for MAX-DOAS measurements

    NASA Astrophysics Data System (ADS)

    Gielen, Clio; Van Roozendael, Michel; Hendrik, Francois; Fayt, Caroline; Hermans, Christian; Pinardi, Gaia; Vlemmix, Tim

    2013-04-01

    is easily detectable. Additional information is derived from the O4 DSCD measurements, since they are quite sensitive to the change of the light paths due to scattering at different altitudes. For example, thick clouds at low altitude show a very strong increase in the DSCD values due to scattering, combined with a low colour index value due to the intensity screening. In general, our method shows promising results to qualify the sky and cloud conditions of MAX- DOAS measurements, without the need for other external cloud-detection systems such as Brewer instruments or pyrheliometers.

  3. In-vivo quantification of primary microRNA processing by Drosha with a luciferase based system

    SciTech Connect

    Allegra, Danilo; Cooperation Unit 'Mechanisms of Leukemogenesis', B061, DKFZ, Im Neuenheimer Feld 280, 69120 Heidelberg; Mertens, Daniel, E-mail: daniel.mertens@uniklinik-ulm.de

    2011-03-25

    Research highlights: {yields} Posttranscriptional regulation of miRNA processing is difficult to quantify. {yields} Our in-vivo processing assay can quantify Drosha cleavage in live cells. {yields} It is based on luciferase reporters fused with pri-miRNAs. {yields} The assay validates the processing defect caused by a mutation in pri-16-1. {yields} It is a sensitive method to quantify pri-miRNA cleavage by Drosha in live cells. -- Abstract: The RNAse III Drosha is responsible for the first step of microRNA maturation, the cleavage of primary miRNA to produce the precursor miRNA. Processing by Drosha is finely regulated and influences the amount of mature microRNAmore » in a cell. We describe in the present work a method to quantify Drosha processing activity in-vivo, which is applicable to any microRNA. With respect to other methods for measuring Drosha activity, our system is faster and scalable, can be used with any cellular system and does not require cell sorting or use of radioactive isotopes. This system is useful to study regulation of Drosha activity in physiological and pathological conditions.« less

  4. Performance evaluation of structure based and ligand based virtual screening methods on ten selected anti-cancer targets.

    PubMed

    Ramasamy, Thilagavathi; Selvam, Chelliah

    2015-10-15

    Virtual screening has become an important tool in drug discovery process. Structure based and ligand based approaches are generally used in virtual screening process. To date, several benchmark sets for evaluating the performance of the virtual screening tool are available. In this study, our aim is to compare the performance of both structure based and ligand based virtual screening methods. Ten anti-cancer targets and their corresponding benchmark sets from 'Demanding Evaluation Kits for Objective In silico Screening' (DEKOIS) library were selected. X-ray crystal structures of protein-ligand complexes were selected based on their resolution. Openeye tools such as FRED, vROCS were used and the results were carefully analyzed. At EF1%, vROCS produced better results but at EF5% and EF10%, both FRED and ROCS produced almost similar results. It was noticed that the enrichment factor values were decreased while going from EF1% to EF5% and EF10% in many cases. Published by Elsevier Ltd.

  5. LC-MS based screening and targeted profiling methods for complex plant: coffee a case study.

    PubMed

    da Rosa, Jeane Santos; Freitas-Silva, Otniel; Pacheco, Sidney; de Oliveira Godoy, Ronoel Luiz; de Rezende, Claudia Moraes

    2012-11-01

    In the recent years the way of thinking about human health necessarily passes by human food. Recent discoveries are not only concerned about valuable biomolecules but also contaminants. Thus, the screening of substances in animal and vegetable matrices by analytical techniques is focused on the presence and absence of target substance. In both cases, the majority of these substances are present as traces or in very low levels. Contaminants could be naturally present in the food, inserted on it or even developed on it as a consequence of food processing or cooking. Pesticides, mycotoxins, dioxins, acrylamide, Sudan red, melamine and now 4(5)-methylimidazole can be, at present, be listed as some of the world big problems related to food contaminants and adulterants. With the development of liquid chromatography coupled to mass spectrometry (LC-MS-MS), in the last few decades, analysis of some food contaminants in trace levels trace become less laborious, more accurate and precise. The multiple approach of those techniques make possible to obtain many results in one single run. On the other hand, European Union (2002/657/EC) established regulations for analytical methods regarding mass spectrometry as detection tool, showing the importance of this technique in food quality control. The EU criteria uses identification points (IPs) that could be achieved basically with four product ions (including molecular ion) or reduced with the use of high resolution equipments. This kind of mass spectrometers made the IPs criteria more accessible, as the exact mass information is a differential tool. In view of this the aim of this review is to present the actual scenario for mass spectrometry analysis in a complex vegetable food matrix such as roasted coffee, with emphasis on needs and challenges regarding the LC-MS technique in order to meet and contribute to food safety standards in this complex matrix.

  6. A mutant screening method by critical annealing temperature-PCR for site-directed mutagenesis.

    PubMed

    Liu, Ying; Wu, Ting; Song, Jian; Chen, Xuelian; Zhang, Yu; Wan, Yu

    2013-03-11

    Distinguishing desired mutants from parental templates and undesired mutants is a problem not well solved in Quikchange™ mutagenesis. Although Dpn I digestion can eliminate methylated parental (WT) DNA, the efficiency is not satisfying due to the existence of hemi-methylated DNA in the PCR products, which is resistant to Dpn I. The present study designed a novel critical annealing temperature (T(c))-PCR to replace Dpn I digestion for more perfect mutant distinguishing, in which part-overlapping primers containing mutation(s) were used to reduce initial concentration of template DNA in mutagenic PCR. A T(c)-PCR with the same mutagenic primers was performed without Dpn I digestion. The T(c) for each pair of the primers was identified by gradient PCR. The relationship between PCR-identified T(c) and T(m) of the primers was analyzed and modeled with correlation and regression. Gradient PCR identified a T(c) for each of 14 tested mutagenic primers, which could discriminate mismatched parental molecules and undesired mutants from desired mutants. The PCR-identified T(c) was correlated to the primer's T(m) (r = 0.804, P<0.0001). Thus, in practical applications, the T(c) can be easily calculated with a regression equation, T(c)= 48.81 + 0.253*T(m). The new protocol introduced a novel T(c)-PCR method for mutant screening which can more efficiently and accurately select against parental molecules and undesired mutations in mutagenic sequence segments.

  7. Screening method for inhibitors against formosan subterranean termite beta-glucosidases in vivo.

    PubMed

    Zhu, Betty C R; Henderson, Gregg; Laine, Roger A

    2005-02-01

    Cellulose, a main structural constituent of plants, is the major nutritional component for wood-feeding termites. Enzymatic hydrolysis of cellulose to glucose occurs by the action of cellulases, a mixture of the three major classes of enzymes including endo-1,4-beta-glucanases, exo-1,4-beta-glucanases, and beta-glucosidase. Lower termites, such as the Formosan subterranean termite, Coptotermes formosanus Shiraki, require cellulolytic protozoa to efficiently digest cellulose for survival. Inhibitors developed against any of these cellulase system enzymes would be a potential termite treatment avenue. Our effort was to develop a screening system to determine whether termites could be controlled by administration of cellulase system inhibitors. Some reported compounds such as gluconolactone, conduritol B epoxide, and 1-deoxynojirimycin are potential beta-glucosidase inhibitors, but they have only been tested in vitro. We describe an in vivo method to test the inhibitory ability of the designated chemicals to act on beta-1,4-glucosidases, one member of the cellulase system that is the key step that releases glucose for use as an energy and carbon source for termites. Inhibition in releasing glucose from cellooligosaccharides might be sufficient to starve termites. Fluorescein di-beta-D-glucopyranoside was used as the artificial enzyme substrate and the fluorescent intensity of the reaction product (fluorescein) quantified with an automated fluorescence plate reader. Several known in vitro beta-1,4-glucosidase inhibitors were tested in vivo, and their inhibitory potential was determined. Endogenous and protozoan cellulase activities are both assumed to play a role.

  8. Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model.

    PubMed

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2018-04-01

    Tracheobronchial stents are used to restore patency to stenosed airways. However, these devices are associated with many complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. Of these, granulation tissue formation is the complication that most frequently requires costly secondary interventions. In this study a biomechanical lung modelling framework recently developed by the authors to capture the lung in-vivo stress state under physiological loading is employed in conjunction with ovine pre-clinical stenting results and device experimental data to evaluate the effect of stent interaction on granulation tissue formation. Stenting is simulated using a validated model of a prototype covered laser-cut tracheobronchial stent in a semi-specific biomechanical lung model, and physiological loading is performed. Two computational methods are then used to predict possible granulation tissue formation: the standard method which utilises the increase in maximum principal stress change, and a newly proposed method which compares the change in contact pressure over a respiratory cycle. These computational predictions of granulation tissue formation are then compared to pre-clinical stenting observations after a 6-week implantation period. Experimental results of the pre-clinical stent implantation showed signs of granulation tissue formation both proximally and distally, with a greater proximal reaction. The standard method failed to show a correlation with the experimental results. However, the contact change method showed an apparent correlation with granulation tissue formation. These results suggest that this new method could be used as a tool to improve future device designs.

  9. A comparison of two visual inspection methods for cervical cancer screening among HIV-infected women in Kenya

    PubMed Central

    Sneden, Jennifer; Leslie, Hannah H; Abdulrahim, Naila; Maloba, May; Bukusi, Elizabeth; Cohen, Craig R

    2014-01-01

    Abstract Objective To determine the optimal strategy for cervical cancer screening in women with human immunodeficiency virus (HIV) infection by comparing two strategies: visual inspection of the cervix with acetic acid (VIA) and VIA followed immediately by visual inspection with Lugol’s iodine (VIA/VILI) in women with a positive VIA result. Methods Data from a cervical cancer screening programme embedded in two HIV clinic sites in western Kenya were evaluated. Women at a central site underwent VIA, while women at a peripheral site underwent VIA/VILI. All women positive for cervical intraepithelial neoplasia grade 2 or worse (CIN 2+) on VIA and/or VILI had a confirmatory colposcopy, with a biopsy if necessary. Overall test positivity, positive predictive value (PPV) and the CIN 2+ detection rate were calculated for the two screening methods, with biopsy being the gold standard. Findings Between October 2007 and October 2010, 2338 women were screened with VIA and 1124 with VIA/VILI. In the VIA group, 26.4% of the women tested positive for CIN 2+; in the VIA/VILI group, 21.7% tested positive (P < 0.01). Histologically confirmed CIN 2+ was detected in 8.9% and 7.8% (P = 0.27) of women in the VIA and VIA/VILI groups, respectively. The PPV of VIA for biopsy-confirmed CIN 2+ in a single round of screening was 35.2%, compared with 38.2% for VIA/VILI (P = 0.41). Conclusion The absence of any differences between VIA and VIA/VILI in detection rates or PPV for CIN 2+ suggests that VIA, an easy testing procedure, can be used alone as a cervical cancer screening strategy in low-income settings. PMID:24700979

  10. Using geographic methods to inform cancer screening interventions for South Asians in Ontario, Canada.

    PubMed

    Lofters, Aisha K; Gozdyra, Piotr; Lobb, Rebecca

    2013-04-26

    Literature suggests that South Asians in Ontario, Canada are under-screened for breast, cervical and colorectal cancer. Accordingly, we are involved in a community-engaged multi-phase study aimed at increasing cancer screening for this vulnerable group. In the work described in this manuscript, we aimed to use visual displays of spatial analyses to identify the most appropriate small geographic areas in which to pilot targeted cancer screening interventions for Ontario's South Asian community. We used Geographic Information Systems (GIS), including Local Indicators of Spatial Association (LISA) using GeoDa software, and population-level administrative data to create multi-layered maps of: i) rates of appropriate cancer screening, ii) the percentage of residents of South Asian ethnicity, and iii) the locations of primary care practices and community health centres by census tract in the Peel Region of Ontario (population: 1.2 million). The maps were shared with partner health service and community service organizations at an intervention development workgroup meeting to examine face validity. The lowest rates of appropriate cancer screening for census tracts across the region were 51.1% for cervical cancer, 48.5% for breast cancer, and 42.5% for colorectal cancer. We found marked variation both in screening rates and in the proportion of South Asians residents by census tract but lower screening rates in the region were consistently associated with larger South Asian populations. The LISA analysis identified a high-risk area consisting of multiple neighbouring census tracts with relatively low screening rates for all three cancer types and with a relatively large South Asian population. Partner organizations recognized and validated the geographic location highlighted by the LISA analysis. Many primary care practices are located in this high-risk area, with one community health centre located very nearby. In this populous region of Ontario, South Asians are more

  11. Comparison of Cardiovascular Risk Screening Methods and Mortality Data among Hungarian Primary Care Population: Preliminary Results of the First Government-Financed Managed Care Program.

    PubMed

    Móczár, Csaba; Rurik, Imre

    2015-09-01

    Besides participation in the primary prevention, screening as secondary prevention is an important requirement for primary care services. The effect of this work is influenced by the characteristics of individual primary care practices and doctors' screening habits, as well as by the regulation of screening processes and available financial resources. Between 1999 and 2009, a managed care program was introduced and carried out in Hungary, financed by the government. This financial support and motivation gave the opportunity to increase the number of screenings. 4,462 patients of 40 primary care practices were screened on the basis of SCORE risk assessment. The results of the screening were compared on the basis of two groups of patients, namely: those who had been pre-screened (pre-screening method) for known risk factors in their medical history (smoking, BMI, age, family cardiovascular history), and those randomly screened. The authors also compared the mortality data of participating primary care practices with the regional and national data. The average score was significantly higher in the pre-screened group of patients, regardless of whether the risk factors were considered one by one or in combination. Mortality was significantly lower in the participating primary practices than had been expected on the basis of the national mortality data. This government-financed program was a big step forward to establish a proper screening method within Hungarian primary care. Performing cardiovascular screening of a selected target group is presumably more appropriate than screening within a randomly selected population. Both methods resulted in a visible improvement in regional mortality data, though it is very likely that with pre-screening a more cost-effective selection for screening may be obtained.

  12. Development of a method for efficient cost-effective screening of Aspergillus niger mutants having increased production of glucoamylase.

    PubMed

    Zhu, Xudong; Arman, Bessembayev; Chu, Ju; Wang, Yonghong; Zhuang, Yingping

    2017-05-01

    To develop an efficient cost-effective screening process to improve production of glucoamylase in Aspergillus niger. The cultivation of A. niger was achieved with well-dispersed morphology in 48-deep-well microtiter plates, which increased the throughput of the samples compared to traditional flask cultivation. There was a close negative correlation between glucoamylase and its pH of the fermentation broth. A novel high-throughput analysis method using Methyl Orange was developed. When compared to the conventional analysis method using 4-nitrophenyl α-D-glucopyranoside as substrate, a correlation coefficient of 0.96 by statistical analysis was obtained. Using this novel screening method, we acquired a strain with an activity of 2.2 × 10 3  U ml -1 , a 70% higher yield of glucoamylase than its parent strain.

  13. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  14. Development of Ultrasound to Measure In-Vivo Dynamic Cervical Spine Intervertebral Disc Mechanics

    DTIC Science & Technology

    2016-01-01

    Award Number: W81XWH-13-1-0050 TITLE: Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc Mechanics PRINCIPAL...CONTRACT NUMBER W81XWH-13-1-0050 Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc Mechanics 5b. GRANT NUMBER 5c...elasticity during compression or tension. As a portable, low cost imaging modality, the dual ultrasound system quantified cervical spine IVD displacement and

  15. Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc Mechanics

    DTIC Science & Technology

    2015-01-01

    1 AD_________ Award Number: W81XWH-13-1-0050 TITLE: Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc...COVERED 27 Dec 2013 - 26 Dec 2014 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine...Approved for Public Release; Distribution Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Neck pain is pervasive problems in military population

  16. Overview of a workshop on screening methods for detecting potential (anti-) estrogenic/androgenic chemicals in wildlife

    USGS Publications Warehouse

    Ankley, Gerald T.; Mihaich, Ellen; Stahl, Ralph G.; Tillitt, Donald E.; Colborn, Theo; McMaster, Suzzanne; Miller, Ron; Bantle, John; Campbell, Pamela; Denslow, Nancy; Dickerson, Richard L.; Folmar, Leroy C.; Fry, Michael; Giesy, John P.; Gray, L. Earl; Guiney, Patrick; Hutchinson, Thomas; Kennedy, Sean W.; Kramer, Vincent; LeBlanc, Gerald A.; Mayes, Monte; Nimrod, Alison; Patino, Reynaldo; Peterson, Richard; Purdy, Richard; Ringer, Robert; Thomas, Peter C.; Touart, Les; Van Der Kraak, Glen; Zacharewski, Tim

    1998-01-01

    The U.S. Congress has passed legislation requiring the U.S. Environmental Protection Agency (U.S. EPA) to develop, validate, and implement screening tests for identifying potential endocrine-disrupting chemicals within 3 years. To aid in the identification of methods suitable for this purpose, the U.S. EPA, the Chemical Manufacturers Association, and the World Wildlife Fund sponsored several workshops, including the present one, which dealt with wildlife species. This workshop was convened with 30 international scientists representing multiple disciplines in March 1997 in Kansas City, Missouri, USA. Participants at the meeting identified methods in terms of their ability to indicate (anti-) estrogenic/androgenic effects, particularly in the context of developmental and reproductive processes. Data derived from structure-activity relationship models and in vitro test systems, although useful in certain contexts, cannot at present replace in vivo tests as the sole basis for screening. A consensus was reached that existing mammalian test methods (e.g., with rats or mice) generally are suitable as screens for assessing potential (anti-) estrogenic/ androgenic effects in mammalian wildlife. However, due to factors such as among-class variation in receptor structure and endocrine function, it is uncertain if these mammalian assays would be of broad utility as screens for other classes of vertebrate wildlife. Existing full and partial life-cycle tests with some avian and fish species could successfully identify chemicals causing endocrine disruption; however, these long-term tests are not suitable for routine screening. However, a number of short-term tests with species from these two classes exist that could serve as effective screening tools for chemicals inducing (anti-) estrogenic/androgenic effects. Existing methods suitable for identifying chemicals with these mechanisms of action in reptiles and amphibians are limited, but in the future, tests with species from

  17. An efficient screening method for the isolation of heterotrophic bacteria influencing growth of diatoms under photoautotrophic conditions.

    PubMed

    Zecher, Karsten; Jagmann, Nina; Seemann, Philipp; Philipp, Bodo

    2015-12-01

    Interactions between photoautotrophic diatoms and heterotrophic bacteria are important for the biogeochemical C-cycle in the oceans. Additionally, biofilms formed by diatoms and bacteria are the initiating step of biofouling processes, which causes high costs in shipping. Despite this ecological and economical importance, the knowledge about biochemical and molecular mechanisms underlying these interkingdom interactions is relatively small. For analyzing these mechanisms, laboratory model systems are required. In this study, an efficient screening method for isolating bacteria influencing photoautotrophic diatom growth was established. First, diatom cultures of Phaeodactylum tricornutum and Thalassiosira pseudonana were made axenic by applying β-lactam antibiotics. Second, a non-invasive method for measuring growth of multiple parallel diatom cultures by chlorophyll fluorescence was established. This method allowed semi-quantitative chlorophyll determination of cultures with up to 3 μg (chlorophyll) ml(-1). Axenic diatom cultures were then used for enriching bacteria and led to the isolation of 24 strains influencing growth of both diatom strains in various ways. For example, Rheinheimera sp. strain Tn16 inhibited growth of T. pseudonana, while it stimulated growth and cell aggregation of P. tricornutum. Thus, this screening method is appropriate for isolating heterotrophic bacteria showing different interactions with different diatom species ranging from synergistic to antagonistic. In consecutive applications, this method will be useful to screen for bacterial mutants with altered phenotypes regarding the influence on diatom growth. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Taguchi's technique: an effective method for improving X-ray medical radiographic screen performance.

    PubMed

    Vlachogiannis, J G

    2003-01-01

    Taguchi's technique is a helpful tool to achieve experimental optimization of a large number of decision variables with a small number of off-line experiments. The technique appears to be an ideal tool for improving the performance of X-ray medical radiographic screens under a noise source. Currently there are very many guides available for improving the efficiency of X-ray medical radiographic screens. These guides can be refined using a second-stage parameter optimization. based on Taguchi's technique, selecting the optimum levels of controllable X-ray radiographic screen factors. A real example of the proposed technique is presented giving certain performance criteria. The present research proposes the reinforcement of X-ray radiography by Taguchi's technique as a novel hardware mechanism.

  19. Mammogram screening in Chile: Using mixed methods to implement health policy planning at the primary care level

    PubMed Central

    Puschel, Klaus; Thompson, Beti

    2011-01-01

    Summary Breast cancer has the highest incidence of all cancers among women in Chile. In 2005, a national health program progressively introduced free mammography screening for women aged 50 and older; however, three years later the rates of compliance with mammographic screening was only 12% in Santiago, the capital city of Chile. This implementation article combines the findings of two previous studies that applied qualitative and quantitative methods to improve mammography screening in an area of Santiago. Socio-cultural and accessibility factors were identified as barriers and facilitators during the qualitative phase of the study and then applied to the design of a quantitative randomized clinical trial. After six months of intervention, 6% of women in the standard care group, 51.8% in the low intensity intervention group, and 70.1% in the high intensity intervention group had undergone a screening mammogram. This review discusses how the utilization of mixed methods research can contribute to the improvement of the implementation of health policies in local communities. PMID:21334897

  20. Virtual screening applications: a study of ligand-based methods and different structure representations in four different scenarios.

    PubMed

    Hristozov, Dimitar P; Oprea, Tudor I; Gasteiger, Johann

    2007-01-01

    Four different ligand-based virtual screening scenarios are studied: (1) prioritizing compounds for subsequent high-throughput screening (HTS); (2) selecting a predefined (small) number of potentially active compounds from a large chemical database; (3) assessing the probability that a given structure will exhibit a given activity; (4) selecting the most active structure(s) for a biological assay. Each of the four scenarios is exemplified by performing retrospective ligand-based virtual screening for eight different biological targets using two large databases--MDDR and WOMBAT. A comparison between the chemical spaces covered by these two databases is presented. The performance of two techniques for ligand--based virtual screening--similarity search with subsequent data fusion (SSDF) and novelty detection with Self-Organizing Maps (ndSOM) is investigated. Three different structure representations--2,048-dimensional Daylight fingerprints, topological autocorrelation weighted by atomic physicochemical properties (sigma electronegativity, polarizability, partial charge, and identity) and radial distribution functions weighted by the same atomic physicochemical properties--are compared. Both methods were found applicable in scenario one. The similarity search was found to perform slightly better in scenario two while the SOM novelty detection is preferred in scenario three. No method/descriptor combination achieved significant success in scenario four.

  1. Incorporating Virtual Reactions into a Logic-based Ligand-based Virtual Screening Method to Discover New Leads

    PubMed Central

    Reynolds, Christopher R; Muggleton, Stephen H; Sternberg, Michael J E

    2015-01-01

    The use of virtual screening has become increasingly central to the drug development pipeline, with ligand-based virtual screening used to screen databases of compounds to predict their bioactivity against a target. These databases can only represent a small fraction of chemical space, and this paper describes a method of exploring synthetic space by applying virtual reactions to promising compounds within a database, and generating focussed libraries of predicted derivatives. A ligand-based virtual screening tool Investigational Novel Drug Discovery by Example (INDDEx) is used as the basis for a system of virtual reactions. The use of virtual reactions is estimated to open up a potential space of 1.21×1012 potential molecules. A de novo design algorithm known as Partial Logical-Rule Reactant Selection (PLoRRS) is introduced and incorporated into the INDDEx methodology. PLoRRS uses logical rules from the INDDEx model to select reactants for the de novo generation of potentially active products. The PLoRRS method is found to increase significantly the likelihood of retrieving molecules similar to known actives with a p-value of 0.016. Case studies demonstrate that the virtual reactions produce molecules highly similar to known actives, including known blockbuster drugs. PMID:26583052

  2. Development of a small-molecule screening method for inhibitors of cellular response to myostatin and activin A.

    PubMed

    Cash, Jennifer N; Angerman, Elizabeth B; Kirby, R Jason; Merck, Lisa; Seibel, William L; Wortman, Matthew D; Papoian, Ruben; Nelson, Sandra; Thompson, Thomas B

    2013-08-01

    Myostatin, a member of the transforming growth factor (TGF)-β family of secreted ligands, is a strong negative regulator of muscle growth. As such, therapeutic inhibitors of myostatin are actively being investigated for their potential in the treatment of muscle-wasting diseases such as muscular dystrophy and sarcopenia. Here, we sought to develop a high-throughput screening (HTS) method for small-molecule inhibitors that target myostatin. We created a HEK293 stable cell line that expresses the (CAGA)12-luciferase reporter construct and robustly responds to signaling of certain classes of TGF-β family ligands. After optimization and miniaturization of the assay to a 384-well format, we successfully screened a library of compounds for inhibition of myostatin and the closely related activin A. Selection of some of the tested compounds was directed by in silico screening against myostatin, which led to an enrichment of target hits as compared with random selection. Altogether, we present an HTS method that will be useful for screening potential inhibitors of not only myostatin but also many other ligands of the TGF-β family.

  3. Comparison of the Modified-Hodge test, Carba NP test, and carbapenem inactivation method as screening methods for carbapenemase-producing Enterobacteriaceae.

    PubMed

    Yamada, Kageto; Kashiwa, Machiko; Arai, Katsumi; Nagano, Noriyuki; Saito, Ryoichi

    2016-09-01

    We compared three screening methods for carbapenemase-producing Enterobacteriaceae. While the Modified-Hodge test and Carba NP test produced false-negative results for OXA-48-like and mucoid NDM producers, the carbapenem inactivation method (CIM) showed positive results for these isolates. Although the CIM required cultivation time, it is well suited for general clinical laboratories. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Colonoscopy screening for colorectal cancer: the outcomes of two recruitment methods.

    PubMed

    Corbett, Mike; Chambers, Sharon L; Shadbolt, Bruce; Hillman, Lybus C; Taupin, Doug

    2004-10-18

    To determine the response to colorectal cancer (CRC) screening by colonoscopy, through direct invitation or through invitation by general practitioners. Two-way comparison of randomised population sampling versus cluster sampling of a representative general practice population in the Australian Capital Territory, May 2002 to January 2004. Invitation to screen, assessment for eligibility, interview, and colonoscopy. 881 subjects aged 55-74 years were invited to screen: 520 from the electoral roll (ER) sample and 361 from the general practice (GP) cluster sample. Response rate, participation rate, and rate of adenomatous polyps in the screened group. Participation was similar in the ER arm (35.1%; 95% CI, 30.2%-40.3%) and the GP arm (40.1%; 95% CI, 29.2%-51.0%) after correcting for ineligibility, which was higher in the ER arm. Superior eligibility in the GP arm was offset by the labour of manual record review. Response rates after two invitations were similar for the two groups (ER arm: 78.8%; 95% CI, 75.1%-82.1%; GP arm: 81.7%; 95% CI, 73.8%-89.6%). Overall, 53.4% ineligibility arose from having a colonoscopy in the past 10 years (ER arm, 98/178; GP arm, 42/84). Of 231 colonoscopies performed, 229 were complete, with 32% of subjects screened having adenomatous polyps. Colonoscopy-based CRC screening yields similar response and participation rates with either random population sampling or general practice cluster sampling, with population sampling through the electoral roll providing greater ease of recruitment.

  5. Revision of FMM-Yukawa: An adaptive fast multipole method for screened Coulomb interactions

    NASA Astrophysics Data System (ADS)

    Zhang, Bo; Huang, Jingfang; Pitsianis, Nikos P.; Sun, Xiaobai

    2010-12-01

    FMM-YUKAWA is a mathematical software package primarily for rapid evaluation of the screened Coulomb interactions of N particles in three dimensional space. Since its release, we have revised and re-organized the data structure, software architecture, and user interface, for the purpose of enabling more flexible, broader and easier use of the package. The package and its documentation are available at http://www.fastmultipole.org/, along with a few other closely related mathematical software packages. New version program summaryProgram title: FMM-Yukawa Catalogue identifier: AEEQ_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEQ_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU GPL 2.0 No. of lines in distributed program, including test data, etc.: 78 704 No. of bytes in distributed program, including test data, etc.: 854 265 Distribution format: tar.gz Programming language: FORTRAN 77, FORTRAN 90, and C. Requires gcc and gfortran version 4.4.3 or later Computer: All Operating system: Any Classification: 4.8, 4.12 Catalogue identifier of previous version: AEEQ_v1_0 Journal reference of previous version: Comput. Phys. Comm. 180 (2009) 2331 Does the new version supersede the previous version?: Yes Nature of problem: To evaluate the screened Coulomb potential and force field of N charged particles, and to evaluate a convolution type integral where the Green's function is the fundamental solution of the modified Helmholtz equation. Solution method: The new version of fast multipole method (FMM) that diagonalizes the multipole-to-local translation operator is applied with the tree structure adaptive to sample particle locations. Reasons for new version: To handle much larger particle ensembles, to enable the iterative use of the subroutines in a solver, and to remove potential contention in assignments for parallelization. Summary of revisions: The software package FMM-Yukawa has been

  6. A novel automatic quantification method for high-content screening analysis of DNA double strand-break response.

    PubMed

    Feng, Jingwen; Lin, Jie; Zhang, Pengquan; Yang, Songnan; Sa, Yu; Feng, Yuanming

    2017-08-29

    High-content screening is commonly used in studies of the DNA damage response. The double-strand break (DSB) is one of the most harmful types of DNA damage lesions. The conventional method used to quantify DSBs is γH2AX foci counting, which requires manual adjustment and preset parameters and is usually regarded as imprecise, time-consuming, poorly reproducible, and inaccurate. Therefore, a robust automatic alternative method is highly desired. In this manuscript, we present a new method for quantifying DSBs which involves automatic image cropping, automatic foci-segmentation and fluorescent intensity measurement. Furthermore, an additional function was added for standardizing the measurement of DSB response inhibition based on co-localization analysis. We tested the method with a well-known inhibitor of DSB response. The new method requires only one preset parameter, which effectively minimizes operator-dependent variations. Compared with conventional methods, the new method detected a higher percentage difference of foci formation between different cells, which can improve measurement accuracy. The effects of the inhibitor on DSB response were successfully quantified with the new method (p = 0.000). The advantages of this method in terms of reliability, automation and simplicity show its potential in quantitative fluorescence imaging studies and high-content screening for compounds and factors involved in DSB response.

  7. From molecular engineering to process engineering: development of high-throughput screening methods in enzyme directed evolution.

    PubMed

    Ye, Lidan; Yang, Chengcheng; Yu, Hongwei

    2018-01-01

    With increasing concerns in sustainable development, biocatalysis has been recognized as a competitive alternative to traditional chemical routes in the past decades. As nature's biocatalysts, enzymes are able to catalyze a broad range of chemical transformations, not only with mild reaction conditions but also with high activity and selectivity. However, the insufficient activity or enantioselectivity of natural enzymes toward non-natural substrates limits their industrial application, while directed evolution provides a potent solution to this problem, thanks to its independence on detailed knowledge about the relationship between sequence, structure, and mechanism/function of the enzymes. A proper high-throughput screening (HTS) method is the key to successful and efficient directed evolution. In recent years, huge varieties of HTS methods have been developed for rapid evaluation of mutant libraries, ranging from in vitro screening to in vivo selection, from indicator addition to multi-enzyme system construction, and from plate screening to computation- or machine-assisted screening. Recently, there is a tendency to integrate directed evolution with metabolic engineering in biosynthesis, using metabolites as HTS indicators, which implies that directed evolution has transformed from molecular engineering to process engineering. This paper aims to provide an overview of HTS methods categorized based on the reaction principles or types by summarizing related studies published in recent years including the work from our group, to discuss assay design strategies and typical examples of HTS methods, and to share our understanding on HTS method development for directed evolution of enzymes involved in specific catalytic reactions or metabolic pathways.

  8. Cost Analysis of Cot-Side Screening Methods for Neonatal Hypoglycaemia.

    PubMed

    Glasgow, Matthew J; Harding, Jane E; Edlin, Richard

    2018-06-12

    Babies at risk of neonatal hypoglycaemia are often screened using cot-side glucometers, but non-enzymatic glucometers are inaccurate, potentially resulting in over-treatment and under-treatment, and low values require laboratory confirmation. More accurate enzymatic glucometers are available but at apparently higher costs. Our objective was to compare the cost of screening for neonatal hypoglycaemia using point-of-care enzymatic and non-enzymatic glucometers. We used a decision tree to model costs, including consumables and staff time. Sensitivity analyses assessed the impact of staff time, staff costs, probability that low results are confirmed via laboratory testing, false-positive and false-negative rates of non-enzymatic glucometers, and the blood glucose concentration threshold. In the primary analysis, screening using an enzymatic glucometer cost NZD 86.94 (USD 63.47) while using a non-enzymatic glucometer cost NZD 97.08 (USD 70.87) per baby. Sensitivity analyses showed that using an enzymatic glucometer is cost saving with wide variations in staff time and costs, irrespective of the false-positive level of non-enzymatic glucometers, and where ≥78% of low values are laboratory confirmed. Where non-enzymatic glucometers may be less costly (e.g., false-negative rate exceeds 15%), instances of hypoglycaemia will be missed. Reducing the blood glucose concentration threshold to 1.94 mmol/L reduced the incidence of hypoglycaemia from 52 to 13%, and the cost of screening using a non-enzymatic glucometer to NZD 47.71 (USD 34.83). In view of their lower cost in most circumstances and greater accuracy, enzymatic glucometers should be routinely utilised for point-of-care screening for neonatal hypoglycaemia. © 2018 S. Karger AG, Basel.

  9. Developing and validating a perinatal depression screening tool in Kenya blending Western criteria with local idioms: A mixed methods study.

    PubMed

    Green, Eric P; Tuli, Hawa; Kwobah, Edith; Menya, D; Chesire, Irene; Schmidt, Christina

    2018-03-01

    Routine screening for perinatal depression is not common in most primary health care settings. The U.S. Preventive Services Task Force only recently updated their recommendation on depression screening to specifically recommend screening during the pre- and postpartum periods. While practitioners in high-income countries can respond to this new recommendation by implementing one of several existing depression screening tools developed in Western contexts, such as the Edinburgh Postnatal Depression Scale (EPDS) or the Patient Health Questionnaire-9 (PHQ-9), these tools lack strong evidence of cross-cultural equivalence, validity for case finding, and precision in measuring response to treatment in developing countries. Thus, there is a critical need to develop and validate new screening tools for perinatal depression that can be used by lay health workers, primary health care personnel, and patients. Working in rural Kenya, we used free listing, card sorting, and item analysis methods to develop a locally-relevant screening tool that blended Western psychiatric concepts with local idioms of distress. We conducted a validation study with a random sample of 193 pregnant women and new mothers to test the diagnostic accuracy of this scale along with the EPDS and PHQ-9. The sensitivity/specificity of the EPDS and PHQ-9 was estimated to be 0.70/0.72 and 0.70/0.73, respectively. This compared to sensitivity/specificity of 0.90/0.90 for a new 9-item locally-developed tool called the Perinatal Depression Screening (PDEPS). Across these three tools, internal consistency reliability ranged from 0.77 to 0.81 and test-retest reliability ranged from 0.57 to 0.67. The prevalence of depression ranges from 5.2% to 6.2% depending on the clinical reference standard. The EPDS and PHQ-9 are valid and reliable screening tools for perinatal depression in rural Western Kenya, the PDEPS may be a more useful alternative. At less than 10%, the prevalence of depression in this region appears

  10. Establishing high resolution melting analysis: method validation and evaluation for c-RET proto-oncogene mutation screening.

    PubMed

    Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina

    2011-10-06

    Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.

  11. Comparative Analysis of Chemical Profile, Antioxidant, In-vitro and In-vivo Antidiabetic Activities of Juniperus foetidissima Willd. and Juniperus sabina L.

    PubMed Central

    Orhan, Nilüfer; Deliorman Orhan, Didem; Gökbulut, Alper; Aslan, Mustafa; Ergun, Fatma

    2017-01-01

    Fruit and leaves of junipers are commonly used internally as tea and pounded fruits are eaten to lower blood glucose levels in Anatolia. Thus, we aimed to evaluate antidiabetic and antioxidant potential and the chemical profile of Juniperus foetidissima Willd. and J. sabina L. in this study. In-vitro antidiabetic activities of leaf and fruit extracts were examined by their inhibitory activity on α-glucosidase and α-amylase enzymes. Then, in-vivo antidiabetic activities of leaf and fruit extracts of Juniperus species were investigated on streptozotocin-induced diabetic rats. Additionally, antioxidant activities (phosphomolybdenum, ferric-reducing antioxidant power and ABTS radical scavenging activity assays), phytochemical screening tests and high performance liquid chromatography analysis (HPLC) were done. In-vitro enzyme inhibitory effects of the extracts were supported by the results of in-vivo antidiabetic activity studies. Phytochemical screening tests indicated presence of flavonoids, tannins, terpenoids and carbohydrates in the extracts. Amentoflavone was identified as the major compound in the extracts and content of amentoflavone was determined. As a result, Juniperus extracts and its active constituents might be beneficial for diabetes and its complications. PMID:29844777

  12. Toxicology screen

    MedlinePlus

    ... Analgesics - screen; Antidepressants - screen; Narcotics - screen; Phenothiazines - screen; Drug abuse screen; Blood alcohol test ... poisoning) Complicated alcohol abstinence (delirium tremens) Delirium ... Fetal alcohol syndrome Intentional overdose Seizures Stroke ...

  13. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment

    PubMed Central

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-01-01

    Digital PCR has developed rapidly since it was first reported in the 1990s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products. PMID:26239916

  14. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    PubMed

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  15. Species identification in meat products: A new screening method based on high resolution melting analysis of cyt b gene.

    PubMed

    Lopez-Oceja, A; Nuñez, C; Baeta, M; Gamarra, D; de Pancorbo, M M

    2017-12-15

    Meat adulteration by substitution with lower value products and/or mislabeling involves economic, health, quality and socio-religious issues. Therefore, identification and traceability of meat species has become an important subject to detect possible fraudulent practices. In the present study the development of a high resolution melt (HRM) screening method for the identification of eight common meat species is reported. Samples from Bos taurus, Ovis aries, Sus scrofa domestica, Equus caballus, Oryctolagus cuniculus, Gallus gallus domesticus, Meleagris gallopavo and Coturnix coturnix were analyzed through the amplification of a 148 bp fragment from the cyt b gene with a universal primer pair in HRM analyses. Melting profiles from each species, as well as from several DNA mixtures of these species and blind samples, allowed a successful species differentiation. The results demonstrated that the HRM method here proposed is a fast, reliable, and low-cost screening technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Development and application of hybrid structure based method for efficient screening of ligands binding to G-protein coupled receptors

    NASA Astrophysics Data System (ADS)

    Kortagere, Sandhya; Welsh, William J.

    2006-12-01

    G-protein coupled receptors (GPCRs) comprise a large superfamily of proteins that are targets for nearly 50% of drugs in clinical use today. In the past, the use of structure-based drug design strategies to develop better drug candidates has been severely hampered due to the absence of the receptor's three-dimensional structure. However, with recent advances in molecular modeling techniques and better computing power, atomic level details of these receptors can be derived from computationally derived molecular models. Using information from these models coupled with experimental evidence, it has become feasible to build receptor pharmacophores. In this study, we demonstrate the use of the Hybrid Structure Based (HSB) method that can be used effectively to screen and identify prospective ligands that bind to GPCRs. Essentially; this multi-step method combines ligand-based methods for building enriched libraries of small molecules and structure-based methods for screening molecules against the GPCR target. The HSB method was validated to identify retinal and its analogues from a random dataset of ˜300,000 molecules. The results from this study showed that the 9 top-ranking molecules are indeed analogues of retinal. The method was also tested to identify analogues of dopamine binding to the dopamine D2 receptor. Six of the ten top-ranking molecules are known analogues of dopamine including a prodrug, while the other thirty-four molecules are currently being tested for their activity against all dopamine receptors. The results from both these test cases have proved that the HSB method provides a realistic solution to bridge the gap between the ever-increasing demand for new drugs to treat psychiatric disorders and the lack of efficient screening methods for GPCRs.

  17. Efficient method for high-throughput virtual screening based on flexible docking: discovery of novel acetylcholinesterase inhibitors.

    PubMed

    Mizutani, Miho Yamada; Itai, Akiko

    2004-09-23

    A method of easily finding ligands, with a variety of core structures, for a given target macromolecule would greatly contribute to the rapid identification of novel lead compounds for drug development. We have developed an efficient method for discovering ligand candidates from a number of flexible compounds included in databases, when the three-dimensional (3D) structure of the drug target is available. The method, named ADAM&EVE, makes use of our automated docking method ADAM, which has already been reported. Like ADAM, ADAM&EVE takes account of the flexibility of each molecule in databases, by exploring the conformational space fully and continuously. Database screening has been made much faster than with ADAM through the tuning of parameters, so that computational screening of several hundred thousand compounds is possible in a practical time. Promising ligand candidates can be selected according to various criteria based on the docking results and characteristics of compounds. Furthermore, we have developed a new tool, EVE-MAKE, for automatically preparing the additional compound data necessary for flexible docking calculation, prior to 3D database screening. Among several successful cases of lead discovery by ADAM&EVE, the finding of novel acetylcholinesterase (AChE) inhibitors is presented here. We performed a virtual screening of about 160 000 commercially available compounds against the X-ray crystallographic structure of AChE. Among 114 compounds that could be purchased and assayed, 35 molecules with various core structures showed inhibitory activities with IC(50) values less than 100 microM. Thirteen compounds had IC(50) values between 0.5 and 10 microM, and almost all their core structures are very different from those of known inhibitors. The results demonstrate the effectiveness and validity of the ADAM&EVE approach and provide a starting point for development of novel drugs to treat Alzheimer's disease.

  18. A Systematic Protein Refolding Screen Method using the DGR Approach Reveals that Time and Secondary TSA are Essential Variables.

    PubMed

    Wang, Yuanze; van Oosterwijk, Niels; Ali, Ameena M; Adawy, Alaa; Anindya, Atsarina L; Dömling, Alexander S S; Groves, Matthew R

    2017-08-24

    Refolding of proteins derived from inclusion bodies is very promising as it can provide a reliable source of target proteins of high purity. However, inclusion body-based protein production is often limited by the lack of techniques for the detection of correctly refolded protein. Thus, the selection of the refolding conditions is mostly achieved using trial and error approaches and is thus a time-consuming process. In this study, we use the latest developments in the differential scanning fluorimetry guided refolding approach as an analytical method to detect correctly refolded protein. We describe a systematic buffer screen that contains a 96-well primary pH-refolding screen in conjunction with a secondary additive screen. Our research demonstrates that this approach could be applied for determining refolding conditions for several proteins. In addition, it revealed which "helper" molecules, such as arginine and additives are essential. Four different proteins: HA-RBD, MDM2, IL-17A and PD-L1 were used to validate our refolding approach. Our systematic protocol evaluates the impact of the "helper" molecules, the pH, buffer system and time on the protein refolding process in a high-throughput fashion. Finally, we demonstrate that refolding time and a secondary thermal shift assay buffer screen are critical factors for improving refolding efficiency.

  19. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in-vivo studies

    PubMed Central

    Petibon, Yoann; Rakvongthai, Yothin; Fakhri, Georges El; Ouyang, Jinsong

    2017-01-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves -TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in-vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans - each containing 1/8th of the total number of events - were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard Ordered Subset Expectation Maximization (OSEM) reconstruction algorithm on one side, and the One-Step Late Maximum a Posteriori (OSL-MAP) algorithm on the other

  20. Large-scale systematic analysis of 2D fingerprint methods and parameters to improve virtual screening enrichments.

    PubMed

    Sastry, Madhavi; Lowrie, Jeffrey F; Dixon, Steven L; Sherman, Woody

    2010-05-24

    A systematic virtual screening study on 11 pharmaceutically relevant targets has been conducted to investigate the interrelation between 8 two-dimensional (2D) fingerprinting methods, 13 atom-typing schemes, 13 bit scaling rules, and 12 similarity metrics using the new cheminformatics package Canvas. In total, 157 872 virtual screens were performed to assess the ability of each combination of parameters to identify actives in a database screen. In general, fingerprint methods, such as MOLPRINT2D, Radial, and Dendritic that encode information about local environment beyond simple linear paths outperformed other fingerprint methods. Atom-typing schemes with more specific information, such as Daylight, Mol2, and Carhart were generally superior to more generic atom-typing schemes. Enrichment factors across all targets were improved considerably with the best settings, although no single set of parameters performed optimally on all targets. The size of the addressable bit space for the fingerprints was also explored, and it was found to have a substantial impact on enrichments. Small bit spaces, such as 1024, resulted in many collisions and in a significant degradation in enrichments compared to larger bit spaces that avoid collisions.

  1. CORALINA: a universal method for the generation of gRNA libraries for CRISPR-based screening.

    PubMed

    Köferle, Anna; Worf, Karolina; Breunig, Christopher; Baumann, Valentin; Herrero, Javier; Wiesbeck, Maximilian; Hutter, Lukas H; Götz, Magdalena; Fuchs, Christiane; Beck, Stephan; Stricker, Stefan H

    2016-11-14

    The bacterial CRISPR system is fast becoming the most popular genetic and epigenetic engineering tool due to its universal applicability and adaptability. The desire to deploy CRISPR-based methods in a large variety of species and contexts has created an urgent need for the development of easy, time- and cost-effective methods enabling large-scale screening approaches. Here we describe CORALINA (comprehensive gRNA library generation through controlled nuclease activity), a method for the generation of comprehensive gRNA libraries for CRISPR-based screens. CORALINA gRNA libraries can be derived from any source of DNA without the need of complex oligonucleotide synthesis. We show the utility of CORALINA for human and mouse genomic DNA, its reproducibility in covering the most relevant genomic features including regulatory, coding and non-coding sequences and confirm the functionality of CORALINA generated gRNAs. The simplicity and cost-effectiveness make CORALINA suitable for any experimental system. The unprecedented sequence complexities obtainable with CORALINA libraries are a necessary pre-requisite for less biased large scale genomic and epigenomic screens.

  2. Fluorophore Absorption Size Exclusion Chromatography (FA-SEC): An Alternative Method for High-Throughput Detergent Screening of Membrane Proteins.

    PubMed

    Lin, Sung-Yao; Sun, Xing-Han; Hsiao, Yu-Hsuan; Chang, Shao-En; Li, Guan-Syun; Hu, Nien-Jen

    2016-01-01

    Membrane proteins play key roles in many fundamental functions in cells including ATP synthesis, ion and molecule transporter, cell signalling and enzymatic reactions, accounting for ~30% genes of whole genomes. However, the hydrophobic nature of membrane proteins frequently hampers the progress of structure determination. Detergent screening is the critical step in obtaining stable detergent-solubilized membrane proteins and well-diffracting protein crystals. Fluorescence Detection Size Exclusion Chromatography (FSEC) has been developed to monitor the extraction efficiency and monodispersity of membrane proteins in detergent micelles. By tracing the FSEC profiles of GFP-fused membrane proteins, this method significantly enhances the throughput of detergent screening. However, current methods to acquire FSEC profiles require either an in-line fluorescence detector with the SEC equipment or an off-line spectrofluorometer microplate reader. Here, we introduce an alternative method detecting the absorption of GFP (FA-SEC) at 485 nm, thus making this methodology possible on conventional SEC equipment through the in-line absorbance spectrometer. The results demonstrate that absorption is in great correlation with fluorescence of GFP. The comparably weaker absorption signal can be improved by using a longer path-length flow cell. The FA-SEC profiles were congruent with the ones plotted by FSEC, suggesting FA-SEC could be a comparable and economical setup for detergent screening of membrane proteins.

  3. [Working overseas and cardiovascular diseases: application of a screening method on Oil&Gas employees].

    PubMed

    Cappelli, M I; Macchione, M; Pulini, S; Aquilina, T; Cancanelli, G

    2012-01-01

    Working overseas is a reality for decades in the Oil&Gas Industry and many noxae impact on the cardiovascular system. In fitness to work evaluation the physician should consider besides the conventional risk factors, the presence of cardiovascular diseases, and prevent their evolution. A cardiovascular screening and follow up after 2 years was carried out on 42 Oil&Gas employees, over 45 of age, during medical fitness to work. The main tests were ECG, exercise tolerance test (ETT) and echocardiocolordoppler, completed with other instrumental tests. Cardiovascular diseases causing unfitness to working overseas occurred in 7%, blood hypertension in 23%. The screening permitted to diagnose and correct acute cardiovascular diseases, that caused unfitness to work, and disease that can get worse related to occupational risk. Moreover it was fundamental for evaluation of fitness and timing of health surveillance.

  4. A Proposed Method to Predict Preterm Birth Using Clinical Data, Standard Maternal Serum Screening, and Cholesterol

    PubMed Central

    ALLEMAN, Brandon W.; SMITH, Amanda R.; BYERS, Heather M.; BEDELL, Bruce; RYCKMAN, Kelli K.; MURRAY, Jeffrey C.; BOROWSKI, Kristi S.

    2013-01-01

    Objective To create a predictive model for preterm birth (PTB) from available clinical data and serum analytes. Study Design Serum analytes, routine pregnancy screening plus cholesterol and corresponding health information were linked to birth certificate data for a cohort of 2699 Iowa women with serum sampled in the first and second trimester. Stepwise logistic regression was used to select the best predictive model for PTB. Results Serum screening markers remained significant predictors of PTB even after controlling for maternal characteristics. The best predictive model included maternal characteristics, first trimester total cholesterol (TC), TC change between trimesters and second trimester alpha-fetoprotein and inhibin A. The model showed better discriminatory ability than PTB history alone and performed similarly in subgroups of women without past PTB. Conclusions Using clinical and serum screening data a potentially useful predictor of PTB was constructed. Validation and replication in other populations, and incorporation of other measures that identify PTB risk, like cervical length, can be a step towards identifying additional women who may benefit from new or currently available interventions. PMID:23500456

  5. A Study on the Knowledge, Perception, and Use of Breast Cancer Screening Methods and Quality of Care Among Women from Central Mexico.

    PubMed

    Cruz-Castillo, Andrea B; Hernández-Valero, María A; Hovick, Shelly R; Campuzano-González, Martha Elva; Karam-Calderón, Miguel Angel; Bustamante-Montes, L Patricia

    2015-09-01

    Studies on health behaviors have observed several barriers to breast cancer screening, including lack of breast cancer knowledge, distrust of health care providers, and long waiting times to be screened or to receive screening results. We conducted a nested case-control study among a subsample of 200 women 21 years of age and older [100 patients (cases)], who had been diagnosed with breast cancer, and 100 controls, who were screened and found to be free of breast cancer), all residing in the Toluca metropolitan area in central Mexico. We examined how knowledge of breast cancer screening guidelines, perceptions of screening methods, and quality of health care influenced the use of breast cancer screening among study participants. Our study found that the most important factor associated with the decision to have breast cancer screenings was having a positive perception of the quality of care provided by the local health care centers, such as having competent clinic personnel, sufficient screening equipment, and reasonable waiting times to receive screening and to receive the screening results. Therefore, individual health care centers need to focus on the patients' perception of the services received by optimizing the care provided and, in so doing, increase the rates of early diagnosis and reduce the rate of mortality from breast cancer as well as its associated treatment costs.

  6. A Study on the knowledge, perception and use of breast cancer screening methods and quality of care among women from central Mexico

    PubMed Central

    Cruz-Castillo, Andrea B.; Hernández-Valero, María A.; Hovick, Shelly R.; Campuzano-González, Martha Elva; Karam-Calderón, Miguel Angel; Bustamante-Montes, L. Patricia

    2014-01-01

    Studies on health behaviors have observed several barriers to breast cancer screening, including lack of breast cancer knowledge, distrust of health care providers, long waiting times to be screened or to receive screening results. We conducted a nested case-control study among a subsample of 200 women 21 years of age and older (100 cases, who had been diagnosed with breast cancer, and 100 controls, who were screened and found to be free of breast cancer), all residing in the Toluca metropolitan area in central Mexico. We examined how knowledge of breast cancer screening guidelines, perceptions of screening methods, and quality of health care influenced the use of breast cancer screening among study participants. Our study found that the most important factors associated with the decision to have breast cancer screenings was having a positive perception of the quality of care provided by the local health care centers, such as having competent clinic personnel, sufficient screening equipment, and reasonable waiting times to receive screening and to receive the screening results. Therefore, individual health care centers need to focus on the patients’ perception of the services received by optimizing the care provided, and in so doing increase the rates of early diagnosis, reduce the rate of mortality from breast cancer as well as its associated treatment costs. PMID:25182506

  7. A multi-element screening method to identify metal targets for blood biomonitoring in green sea turtles (Chelonia mydas).

    PubMed

    Villa, C A; Finlayson, S; Limpus, C; Gaus, C

    2015-04-15

    Biomonitoring of blood is commonly used to identify and quantify occupational or environmental exposure to chemical contaminants. Increasingly, this technique has been applied to wildlife contaminant monitoring, including for green turtles, allowing for the non-lethal evaluation of chemical exposure in their nearshore environment. The sources, composition, bioavailability and toxicity of metals in the marine environment are, however, often unknown and influenced by numerous biotic and abiotic factors. These factors can vary considerably across time and space making the selection of the most informative elements for biomonitoring challenging. This study aimed to validate an ICP-MS multi-element screening method for green turtle blood in order to identify and facilitate prioritisation of target metals for subsequent fully quantitative analysis. Multi-element screening provided semiquantitative results for 70 elements, 28 of which were also determined through fully quantitative analysis. Of the 28 comparable elements, 23 of the semiquantitative results had an accuracy between 67% and 112% relative to the fully quantified values. In lieu of any available turtle certified reference materials (CRMs), we evaluated the use of human blood CRMs as a matrix surrogate for quality control, and compared two commonly used sample preparation methods for matrix related effects. The results demonstrate that human blood provides an appropriate matrix for use as a quality control material in the fully quantitative analysis of metals in turtle blood. An example for the application of this screening method is provided by comparing screening results from blood of green turtles foraging in an urban and rural region in Queensland, Australia. Potential targets for future metal biomonitoring in these regions were identified by this approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. The SOBANE risk management strategy and the Déparis method for the participatory screening of the risks.

    PubMed

    Malchaire, J B

    2004-08-01

    The first section of the document describes a risk-prevention strategy, called SOBANE, in four levels: screening, observation, analysis and expertise. The aim is to make risk prevention faster, more cost effective, and more effective in coordinating the contributions of the workers themselves, their management, the internal and external occupational health (OH) practitioners and the experts. These four levels are: screening, where the risk factors are detected by the workers and their management, and obvious solutions are implemented; observation, where the remaining problems are studied in more detail, one by one, and the reasons and the solutions are discussed in detail; analysis, where, when necessary, an OH practitioner is called upon to carry out appropriate measurements to develop specific solutions; expertise, where, in very sophisticated and rare cases, the assistance of an expert is called upon to solve a particular problem. The method for the participatory screening of the risks (in French: Dépistage Participatif des Risques), Déparis, is proposed for the first level screening of the SOBANE strategy. The work situation is systematically reviewed and all the aspects conditioning the easiness, the effectiveness and the satisfaction at work are discussed, in search of practical prevention measures. The points to be studied more in detail at level 2, observation, are identified. The method is carried out during a meeting of key workers and technical staff. The method proves to be simple, sparing in time and means and playing a significant role in the development of a dynamic plan of risk management and of a culture of dialogue in the company.

  9. A Freehand Ultrasound Elastography System with Tracking for In-vivo Applications

    PubMed Central

    Foroughi, Pezhman; Kang, Hyun-Jae; Carnegie, Daniel A.; van Vledder, Mark G.; Choti, Michael A.; Hager, Gregory D.; Boctor, Emad M.

    2012-01-01

    Ultrasound transducers are commonly tracked in modern ultrasound navigation/guidance systems. In this paper, we demonstrate the advantages of incorporating tracking information into ultrasound elastography for clinical applications. First, we address a common limitation of freehand palpation: speckle decorrelation due to out-of-plane probe motion. We show that by automatically selecting pairs of radio frequency (RF) frames with minimal lateral and out-of-plane motions combined with a fast and robust displacement estimation technique greatly improves in-vivo elastography results. We also use tracking information and image quality measure to fuse multiple images with similar strain that are taken roughly from the same location to obtain a high quality elastography image. Finally, we show that tracking information can be used to give the user partial control over the rate of compression. Our methods are tested on tissue mimicking phantom and experiments have been conducted on intra-operative data acquired during animal and human experiments involving liver ablation. Our results suggest that in challenging clinical conditions, our proposed method produces reliable strain images and eliminates the need for a manual search through the ultrasound data in order to find RF pairs suitable for elastography. PMID:23257351

  10. In-vivo characterization of 2D residence time maps in the left ventricle

    NASA Astrophysics Data System (ADS)

    Rossini, Lorenzo; Martinez-Legazpi, Pablo; Bermejo, Javier; Benito, Yolanda; Alhama, Marta; Yotti, Raquel; Perez Del Villar, Candelas; Gonzalez-Mansilla, Ana; Barrio, Alicia; Fernandez-Aviles, Francisco; Shadden, Shawn; Del Alamo, Juan Carlos

    2014-11-01

    Thrombus formation is a multifactorial process involving biology and hemodynamics. Blood stagnation and wall shear stress are linked to thrombus formation. The quantification of residence time of blood in the left ventricle (LV) is relevant for patients affected by ventricular contractility dysfunction. We use a continuum formulation to compute 2D blood residence time (TR) maps in the LV using in-vivo 2D velocity fields in the apical long axis plane obtained from Doppler-echocardiography images of healthy and dilated hearts. The TR maps are generated integrating in time an advection-diffusion equation of a passive scalar with a time-source term. This equation represents the Eulerian translation of DTR / D t = 1 and is solved numerically with a finite volume method on a Cartesian grid using an immersed boundary for the LV wall. Changing the source term and the boundary conditions allows us to track blood transport (direct and retained flow) in the LV and the topology of early (E) and atrial (A) filling waves. This method has been validated against a Lagrangian Coherent Structures analysis, is computationally inexpensive and observer independent, making it a potential diagnostic tool in clinical settings.

  11. A powerful nonparametric method for detecting differentially co-expressed genes: distance correlation screening and edge-count test.

    PubMed

    Zhang, Qingyang

    2018-05-16

    Differential co-expression analysis, as a complement of differential expression analysis, offers significant insights into the changes in molecular mechanism of different phenotypes. A prevailing approach to detecting differentially co-expressed genes is to compare Pearson's correlation coefficients in two phenotypes. However, due to the limitations of Pearson's correlation measure, this approach lacks the power to detect nonlinear changes in gene co-expression which is common in gene regulatory networks. In this work, a new nonparametric procedure is proposed to search differentially co-expressed gene pairs in different phenotypes from large-scale data. Our computational pipeline consisted of two main steps, a screening step and a testing step. The screening step is to reduce the search space by filtering out all the independent gene pairs using distance correlation measure. In the testing step, we compare the gene co-expression patterns in different phenotypes by a recently developed edge-count test. Both steps are distribution-free and targeting nonlinear relations. We illustrate the promise of the new approach by analyzing the Cancer Genome Atlas data and the METABRIC data for breast cancer subtypes. Compared with some existing methods, the new method is more powerful in detecting nonlinear type of differential co-expressions. The distance correlation screening can greatly improve computational efficiency, facilitating its application to large data sets.

  12. Accessibility of standardized information of a national colorectal cancer screening program for low health literate screening invitees: A mixed method study.

    PubMed

    Fransen, Mirjam P; Dekker, Evelien; Timmermans, Daniëlle R M; Uiters, Ellen; Essink-Bot, Marie-Louise

    2017-02-01

    To explore the accessibility of standardized printed information materials of the national Dutch colorectal cancer screening program among low health literate screening invitees and to assess the effect of the information on their knowledge about colorectal cancer and the screening program. Linguistic tools were used to analyze the text and design characteristics. The accessibility, comprehensibility and relevance of the information materials were explored in interviews and in observations (n=25). The effect of the information on knowledge was assessed in an online survey (n=127). The materials employed a simple text and design. However, respondents expressed problems with the amount of information, and the difference between screening and diagnostic follow-up. Knowledge significantly increased in 10 out of 16 items after reading the information but remained low for colorectal cancer risk, sensitivity of testing, and the voluntariness of colorectal cancer screening. Despite intelligible linguistic and design characteristics, screening invitees with low health literacy had problems in accessing, comprehending and applying standard information materials on colorectal cancer screening, and lacked essential knowledge for informed decision-making about participation. To enable equal access to informed decision-making, information strategies need to be adjusted to the skills of low health literate screening invitees. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Screening for Asymptomatic Clostridium difficile Among Bone Marrow Transplant Patients: A Mixed-Methods Study of Intervention Effectiveness and Feasibility.

    PubMed

    Barker, Anna K; Krasity, Benjamin; Musuuza, Jackson; Safdar, Nasia

    2018-02-01

    OBJECTIVE To identify facilitators and barriers to implementation of a Clostridium difficile screening intervention among bone marrow transplant (BMT) patients and to evaluate the clinical effectiveness of the intervention on the rate of hospital-onset C. difficile infection (HO-CDI). DESIGN Before-and-after trial SETTING A 505-bed tertiary-care medical center PARTICIPANTS All 5,357 patients admitted to the BMT and general medicine wards from January 2014 to February 2017 were included in the study. Interview participants included 3 physicians, 4 nurses, and 4 administrators. INTERVENTION All BMT patients were screened within 48 hours of admission. Colonized patients, as defined by a C. difficile-positive polymerase chain reaction (PCR) stool result, were placed under contact precautions for the duration of their hospital stay. METHODS Interview responses were coded according to the Systems Engineering Initiative for Patient Safety conceptual framework. We compared pre- and postintervention HO-CDI rates on BMT and general internal medicine units using time-series analysis. RESULTS Stakeholder engagement, at both the person and organizational level, facilitates standardization and optimization of intervention protocols. While the screening intervention was generally well received, tools and technology were sources of concern. The mean incidence of HO-CDI decreased on the BMT service postintervention (P<.0001). However, the effect of the change in the trend postintervention was not significantly different on BMT compared to the control wards (P=.93). CONCLUSIONS We report the first mixed-methods study to evaluate a C. difficile screening intervention among the BMT population. The positive nature by which the intervention was received by front-line clinical staff, laboratory staff, and administrators is promising for future implementation studies. Infect Control Hosp Epidemiol 2018;39:177-185.

  14. A combined enrichment/polymerase chain reaction based method for the routine screening of Streptococcus agalactiae in pregnant women.

    PubMed

    Munari, F M; De-Paris, F; Salton, G D; Lora, P S; Giovanella, P; Machado, A B M P; Laybauer, L S; Oliveira, K R P; Ferri, C; Silveira, J L S; Laurino, C C F C; Xavier, R M; Barth, A L; Echeverrigaray, S; Laurino, J P

    2012-01-01

    Group B Streptococcus (GBS) is the most common cause of life-threatening infection in neonates. Guidelines from CDC recommend universal screening of pregnant women for rectovaginal GBS colonization. The objective of this study was to compare the performance of a combined enrichment/PCR based method targeting the atr gene in relation to culture using enrichment with selective broth medium (standard method) to identify the presence of GBS in pregnant women. Rectovaginal GBS samples from women at ≥36 weeks of pregnancy were obtained with a swab and analyzed by the two methods. A total of 89 samples were evaluated. The prevalence of positive results for GBS detection was considerable higher when assessed by the combined enrichment/PCR method than with the standard method (35.9% versus 22.5%, respectively). The results demonstrated that the use of selective enrichment broth followed by PCR targeting the atr gene is a highly sensitive, specific and accurate test for GBS screening in pregnant women, allowing the detection of the bacteria even in lightly colonized patients. This PCR methodology may provide a useful diagnostic tool for GBS detection and contributes for a more accurate and effective intrapartum antibiotic and lower newborn mortality and morbidity.

  15. Pre-screening method for somatic cell contamination in human sperm epigenetic studies.

    PubMed

    Jenkins, Timothy G; Liu, Lihua; Aston, Kenneth I; Carrell, Douglas T

    2018-04-01

    Sperm epigenetic profiles are frequently studied and are of great interest in many fields. One major technical concern when assessing these marks is the potential for somatic cell contamination. Because somatic cells have dramatically different epigenetic signatures, even small levels of contamination can result in significant problems in analysis and interpretation of data. In this study we evaluate an assay, which we designed to offer a reliable 'pre-screen' for somatic cell contamination that directly assesses the DNA being used in the study to determine tissue purity. In brief, we designed an inexpensive and simple assay that utilizes the strong differential methylation between sperm and somatic cells at four genomic loci to assess the general purity of samples prior to performing expensive and time intensive assays. The assay is able to reliably detect contamination qualitatively by running the sample on an agarose gel, or quantitatively with the use of a bioanalyzer. With this technique we have found that we can detect potentially contaminating signals in samples of many different types, including those from patients with poor sperm phenotypes (oligozoospermia, asthenozoospermia, and teratozoospermia). We also have found that the use of multiple sites to determine potential contamination is key, as some conditions (asthenozoospermia specifically) appear at one site to reflect a somatic-like profile, while at all other sites it appears to have very typical sperm DNA methylation signatures. Taken together, the use of the assay described herein was effective at identifying contamination and could be implemented in many labs to quickly and inexpensively pre-screen samples prior to performing far more expensive and labor intensive procedures. Additionally, the principles applied to the development of this assay could be easily adapted for the development of other assays to pre-screen different tissue/cell types or model organisms.

  16. Improved method of screening for aflatoxin with a coconut agar medium.

    PubMed Central

    Davis, N D; Iyer, S K; Diener, U L

    1987-01-01

    Nine isolates of Aspergillus flavus and Aspergillus parasiticus were screened for aflatoxin production on a coconut extract agar medium. Aflatoxin-producing colonies were detected under long-wave UV light (365 nm) by blue fluorescence on the reverse side after 2 to 5 days of growth. Aflatoxin production was verified by chemical analysis. Several types of shredded coconut available in the United States were tested and found to be satisfactory. No additives were required. Various parameters affecting the test were investigated. PMID:3116928

  17. Screening of various botanical extracts for antioxidant activity using DPPH free radical method.

    PubMed

    Waqas, Muhammad Khurram; Saqib, Najam-Us; Rashid, Saeed-Ur; Shah, Pervaiz Akhtar; Akhtar, Naveed; Murtaza, Ghulam

    2013-01-01

    Aiming at the exploration of herbal use by society, crude extracts of the seeds of some commonly used medicinal plants (Vitis vinifera, Tamarindus indica and Glycin max) were screened for their free radical scavenging properties using ascorbic acid as standard antioxidant. Free radical scavenging activity was evaluated using 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical. The overall antioxidant activity of grape seeds (Vitis vinifera) was the strongest, followed in descending order by soybean (Glycin max) and tamarind (Tamarindus indica). The seeds extract of Vitis vinifera, Glycin max and Tamarindus indica showed 85.61%, 83.45% and 79.26%, DPPH scavenging activity respectively.

  18. Development of a screening method for the determination of 49 priority pollutants in soil

    SciTech Connect

    Kiang, P.H.; Grob, R.L.

    1986-01-01

    A screening procedure was develop for the determination of 49 priority pollutants in soil. An extraction procedure followed by the capillary gas chromatographic technique was used. Dual pH solutions with methylene chloride were used as extraction solvent system; no sample clean-up procedure was applied. Both base/neutral and acid fractions were analyzed on the same capillary column (SPB-1). The relative standard deviation for 5.1 ppm (51 ..mu..g/ 10 g) concentration in zero soil was less than 25%.

  19. Application of the stochastic tunneling method to high throughput database screening

    NASA Astrophysics Data System (ADS)

    Merlitz, H.; Burghardt, B.; Wenzel, W.

    2003-03-01

    The stochastic tunneling technique is applied to screen a database of chemical compounds to the active site of dihydrofolate reductase for lead candidates in the receptor-ligand docking problem. Using an atomistic force field we consider the ligand's internal rotational degrees of freedom. It is shown that the natural ligand (methotrexate) scores best among 10 000 randomly chosen compounds. We analyze the top scoring compounds to identify hot-spots of the receptor. We mutate the amino acids that are responsible for the hot-spots of the receptor and verify that its specificity is lost upon modification.

  20. Terminate Lung Cancer (TLC) Study - A mixed-methods population approach to increase lung cancer screening awareness and low-dose computed tomography in Eastern Kentucky

    PubMed Central

    Cardarelli, Roberto; Reese, David; Roper, Karen L.; Cardarelli, Kathryn; Feltner, Frances J.; Studts, Jamie L.; Knight, Jennifer R.; Armstrong, Debra; Weaver, Anthony; Shaffer, Dana

    2017-01-01

    For low dose CT lung cancer screening to be effective in curbing disease mortality, efforts are needed to overcome barriers to awareness and facilitate uptake of the current evidence-based screening guidelines. A sequential mixed-methods approach was employed to design a screening campaign utilizing messages developed from community focus groups, followed by implementation of the outreach campaign intervention in two high-risk Kentucky regions. This study reports on rates of awareness and screening in intervention regions, as compared to a control region. PMID:27866066

  1. A Digital PCR-Based Method for Efficient and Highly Specific Screening of Genome Edited Cells

    PubMed Central

    Berman, Jennifer R.; Postovit, Lynne-Marie

    2016-01-01

    The rapid adoption of gene editing tools such as CRISPRs and TALENs for research and eventually therapeutics necessitates assays that can rapidly detect and quantitate the desired alterations. Currently, the most commonly used assay employs “mismatch nucleases” T7E1 or “Surveyor” that recognize and cleave heteroduplexed DNA amplicons containing mismatched base-pairs. However, this assay is prone to false positives due to cancer-associated mutations and/or SNPs and requires large amounts of starting material. Here we describe a powerful alternative wherein droplet digital PCR (ddPCR) can be used to decipher homozygous from heterozygous mutations with superior levels of both precision and sensitivity. We use this assay to detect knockout inducing alterations to stem cell associated proteins, NODAL and SFRP1, generated using either TALENs or an “all-in-one” CRISPR/Cas plasmid that we have modified for one-step cloning and blue/white screening of transformants. Moreover, we highlight how ddPCR can be used to assess the efficiency of varying TALEN-based strategies. Collectively, this work highlights how ddPCR-based screening can be paired with CRISPR and TALEN technologies to enable sensitive, specific, and streamlined approaches to gene editing and validation. PMID:27089539

  2. Adapting High-Throughput Screening Methods and Assays for Biocontainment Laboratories

    PubMed Central

    Tigabu, Bersabeh; White, E. Lucile; Bostwick, Robert; Tower, Nichole; Bukreyev, Alexander; Rockx, Barry; LeDuc, James W.; Noah, James W.

    2015-01-01

    Abstract High-throughput screening (HTS) has been integrated into the drug discovery process, and multiple assay formats have been widely used in many different disease areas but with limited focus on infectious agents. In recent years, there has been an increase in the number of HTS campaigns using infectious wild-type pathogens rather than surrogates or biochemical pathogen-derived targets. Concurrently, enhanced emerging pathogen surveillance and increased human mobility have resulted in an increase in the emergence and dissemination of infectious human pathogens with serious public health, economic, and social implications at global levels. Adapting the HTS drug discovery process to biocontainment laboratories to develop new drugs for these previously uncharacterized and highly pathogenic agents is now feasible, but HTS at higher biosafety levels (BSL) presents a number of unique challenges. HTS has been conducted with multiple bacterial and viral pathogens at both BSL-2 and BSL-3, and pilot screens have recently been extended to BSL-4 environments for both Nipah and Ebola viruses. These recent successful efforts demonstrate that HTS can be safely conducted at the highest levels of biological containment. This review outlines the specific issues that must be considered in the execution of an HTS drug discovery program for high-containment pathogens. We present an overview of the requirements for HTS in high-level biocontainment laboratories. PMID:25710545

  3. A semi high-throughput method for screening small bispecific antibodies with high cytotoxicity.

    PubMed

    Sugiyama, Aruto; Umetsu, Mitsuo; Nakazawa, Hikaru; Niide, Teppei; Onodera, Tomoko; Hosokawa, Katsuhiro; Hattori, Shuhei; Asano, Ryutaro; Kumagai, Izumi

    2017-06-06

    Small bispecific antibodies that induce T-cell-mediated cytotoxicity have the potential to damage late-stage tumor masses to a clinically relevant degree, but their cytotoxicity is critically dependent on their structural and functional properties. Here, we constructed an optimized procedure for identifying highly cytotoxic antibodies from a variety of the T-cell-recruiting antibodies engineered from a series of antibodies against cancer antigens of epidermal growth factor receptor family and T-cell receptors. By developing and applying a set of rapid operations for expression vector construction and protein preparation, we screened the cytotoxicity of 104 small antibodies with diabody format and identified some with 10 3 -times higher cytotoxicity than that of previously reported active diabody. The results demonstrate that cytotoxicity is enhanced by synergistic effects between the target, epitope, binding affinity, and the order of heavy-chain and light-chain variable domains. We demonstrate the importance of screening to determine the critical rules for highly cytotoxic antibodies.

  4. Novel method for high-throughput colony PCR screening in nanoliter-reactors

    PubMed Central

    Walser, Marcel; Pellaux, Rene; Meyer, Andreas; Bechtold, Matthias; Vanderschuren, Herve; Reinhardt, Richard; Magyar, Joseph; Panke, Sven; Held, Martin

    2009-01-01

    We introduce a technology for the rapid identification and sequencing of conserved DNA elements employing a novel suspension array based on nanoliter (nl)-reactors made from alginate. The reactors have a volume of 35 nl and serve as reaction compartments during monoseptic growth of microbial library clones, colony lysis, thermocycling and screening for sequence motifs via semi-quantitative fluorescence analyses. nl-Reactors were kept in suspension during all high-throughput steps which allowed performing the protocol in a highly space-effective fashion and at negligible expenses of consumables and reagents. As a first application, 11 high-quality microsatellites for polymorphism studies in cassava were isolated and sequenced out of a library of 20 000 clones in 2 days. The technology is widely scalable and we envision that throughputs for nl-reactor based screenings can be increased up to 100 000 and more samples per day thereby efficiently complementing protocols based on established deep-sequencing technologies. PMID:19282448

  5. An Unbiased Method To Build Benchmarking Sets for Ligand-Based Virtual Screening and its Application To GPCRs

    PubMed Central

    2015-01-01

    Benchmarking data sets have become common in recent years for the purpose of virtual screening, though the main focus had been placed on the structure-based virtual screening (SBVS) approaches. Due to the lack of crystal structures, there is great need for unbiased benchmarking sets to evaluate various ligand-based virtual screening (LBVS) methods for important drug targets such as G protein-coupled receptors (GPCRs). To date these ready-to-apply data sets for LBVS are fairly limited, and the direct usage of benchmarking sets designed for SBVS could bring the biases to the evaluation of LBVS. Herein, we propose an unbiased method to build benchmarking sets for LBVS and validate it on a multitude of GPCRs targets. To be more specific, our methods can (1) ensure chemical diversity of ligands, (2) maintain the physicochemical similarity between ligands and decoys, (3) make the decoys dissimilar in chemical topology to all ligands to avoid false negatives, and (4) maximize spatial random distribution of ligands and decoys. We evaluated the quality of our Unbiased Ligand Set (ULS) and Unbiased Decoy Set (UDS) using three common LBVS approaches, with Leave-One-Out (LOO) Cross-Validation (CV) and a metric of average AUC of the ROC curves. Our method has greatly reduced the “artificial enrichment” and “analogue bias” of a published GPCRs benchmarking set, i.e., GPCR Ligand Library (GLL)/GPCR Decoy Database (GDD). In addition, we addressed an important issue about the ratio of decoys per ligand and found that for a range of 30 to 100 it does not affect the quality of the benchmarking set, so we kept the original ratio of 39 from the GLL/GDD. PMID:24749745

  6. An unbiased method to build benchmarking sets for ligand-based virtual screening and its application to GPCRs.

    PubMed

    Xia, Jie; Jin, Hongwei; Liu, Zhenming; Zhang, Liangren; Wang, Xiang Simon

    2014-05-27

    Benchmarking data sets have become common in recent years for the purpose of virtual screening, though the main focus had been placed on the structure-based virtual screening (SBVS) approaches. Due to the lack of crystal structures, there is great need for unbiased benchmarking sets to evaluate various ligand-based virtual screening (LBVS) methods for important drug targets such as G protein-coupled receptors (GPCRs). To date these ready-to-apply data sets for LBVS are fairly limited, and the direct usage of benchmarking sets designed for SBVS could bring the biases to the evaluation of LBVS. Herein, we propose an unbiased method to build benchmarking sets for LBVS and validate it on a multitude of GPCRs targets. To be more specific, our methods can (1) ensure chemical diversity of ligands, (2) maintain the physicochemical similarity between ligands and decoys, (3) make the decoys dissimilar in chemical topology to all ligands to avoid false negatives, and (4) maximize spatial random distribution of ligands and decoys. We evaluated the quality of our Unbiased Ligand Set (ULS) and Unbiased Decoy Set (UDS) using three common LBVS approaches, with Leave-One-Out (LOO) Cross-Validation (CV) and a metric of average AUC of the ROC curves. Our method has greatly reduced the "artificial enrichment" and "analogue bias" of a published GPCRs benchmarking set, i.e., GPCR Ligand Library (GLL)/GPCR Decoy Database (GDD). In addition, we addressed an important issue about the ratio of decoys per ligand and found that for a range of 30 to 100 it does not affect the quality of the benchmarking set, so we kept the original ratio of 39 from the GLL/GDD.

  7. Comparing different methods for fast screening of microbiological quality of beach sand aimed at rapid-response remediation.

    PubMed

    Testolin, Renan C; Almeida, Tito C M; Polette, Marcus; Branco, Joaquim O; Fischer, Larissa L; Niero, Guilherme; Poyer-Radetski, Gabriel; Silva, Valéria C; Somensi, Cleder A; Corrêa, Albertina X R; Corrêa, Rogério; Rörig, Leonardo R; Itokazu, Ana Gabriela; Férard, Jean-François; Cotelle, Sylvie; Radetski, Claudemir M

    2017-05-15

    There is scientific evidence that beach sands are a significant contributor to the pathogen load to which visitors are exposed. To develop beach quality guidelines all beach zones must be included in microbiological evaluations, but monitoring methods for beach sand quality are relatively longstanding, expensive, laborious and require moderate laboratory infrastructure. This paper aimed to evaluate the microorganism activity in different beach zones applying and comparing a classical method of membrane filtration (MF) with two colorimetric screening methods based on fluorescein (FDA) and tetrazolium (TTC) salt biotransformation to evaluate a new rapid and low-cost method for beach sand microbiological contamination assessments. The colorimetric results can help beach managers to evaluate rapidly and at low cost the microbiological quality of different beach zones in order to decide whether remedial actions need to be adopted to prevent exposure of the public to microbes due to beach sand and/or water contamination. Copyright © 2017. Published by Elsevier Ltd.

  8. Virtual screening and rational drug design method using structure generation system based on 3D-QSAR and docking.

    PubMed

    Chen, H F; Dong, X C; Zen, B S; Gao, K; Yuan, S G; Panaye, A; Doucet, J P; Fan, B T

    2003-08-01

    An efficient virtual and rational drug design method is presented. It combines virtual bioactive compound generation with 3D-QSAR model and docking. Using this method, it is possible to generate a lot of highly diverse molecules and find virtual active lead compounds. The method was validated by the study of a set of anti-tumor drugs. With the constraints of pharmacophore obtained by DISCO implemented in SYBYL 6.8, 97 virtual bioactive compounds were generated, and their anti-tumor activities were predicted by CoMFA. Eight structures with high activity were selected and screened by the 3D-QSAR model. The most active generated structure was further investigated by modifying its structure in order to increase the activity. A comparative docking study with telomeric receptor was carried out, and the results showed that the generated structures could form more stable complexes with receptor than the reference compound selected from experimental data. This investigation showed that the proposed method was a feasible way for rational drug design with high screening efficiency.

  9. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    PubMed

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  10. In-vivo dynamic characterization of microneedle skin penetration using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Enfield, Joey; O'Connell, Marie-Louise; Lawlor, Kate; Jonathan, Enock; O'Mahony, Conor; Leahy, Martin

    2010-07-01

    The use of microneedles as a method of circumventing the barrier properties of the stratum corneum is receiving much attention. Although skin disruption technologies and subsequent transdermal diffusion rates are being extensively studied, no accurate data on depth and closure kinetics of microneedle-induced skin pores are available, primarily due to the cumbersome techniques currently required for skin analysis. We report on the first use of optical coherence tomography technology to image microneedle penetration in real time and in vivo. We show that optical coherence tomography (OCT) can be used to painlessly measure stratum corneum and epidermis thickness, as well as microneedle penetration depth after microneedle insertion. Since OCT is a real-time, in-vivo, nondestructive technique, we also analyze skin healing characteristics and present quantitative data on micropore closure rate. Two locations (the volar forearm and dorsal aspect of the fingertip) have been assessed as suitable candidates for microneedle administration. The results illustrate the applicability of OCT analysis as a tool for microneedle-related skin characterization.

  11. In-vivo RGB marking and multicolour single-cell tracking in the adult brain

    PubMed Central

    Gomez-Nicola, Diego; Riecken, Kristoffer; Fehse, Boris; Perry, V. Hugh

    2014-01-01

    In neuroscience it is a technical challenge to identify and follow the temporal and spatial distribution of cells as they differentiate. We hypothesised that RGB marking, the tagging of individual cells with unique hues resulting from simultaneous expression of the three basic colours red, green and blue, provides a convenient toolbox for the study of the CNS anatomy at the single-cell level. Using γ-retroviral and lentiviral vector sets we describe for the first time the in-vivo multicolour RGB marking of neurons in the adult brain. RGB marking also enabled us to track the spatial and temporal fate of neural stem cells in the adult brain. The application of different viral envelopes and promoters provided a useful approach to track the generation of neurons vs. glial cells at the neurogenic niche, allowing the identification of the prominent generation of new astrocytes to the striatum. Multicolour RGB marking could serve as a universal and reproducible method to study and manipulate the CNS at the single-cell level, in both health and disease. PMID:25531807

  12. Rapid and direct detection of Invivo kinetics of pathogenic bacterial infection from mouse blood and urine.

    PubMed

    Gopal, Judy; Lee, Chia-Hsun; Wu, Hui-Fen

    2012-06-06

    This study demonstrates the first use of matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to trace the Invivo infection kinetics of the well known deadly pathogen Staphylococcus aureus in Swiss albino mice. The growth curve of the bacteria from the point of injection (200μL of bacterial suspension (10(8)cfu/mL)) into the mouse blood till mortality (death) was periodically analyzed using the plate counting method and MALDI-MS. Bacterial counts of 10(3)cfu/mL were observed in the log phase of the growth curve in the blood and 10(2)cfu/mL were observed in the urine samples. Death occurred in the log phase of the growth curve, where the bacterial counts showed steady increase. In other cases, the bacteria counts started decreasing after 48h and by 96h the bacteria got totally eliminated from the mouse and these mice survived. Direct MALDI-MS was not feasible for tracking the bacteria in the infected blood. However, ionic liquid 1-Butyl-3-methylimidazolium tetrafluoroborate was successful in enabling bacterial detection amidst the strong blood peaks. But, in the case of the urine analysis, it was observed that direct MALDI-MS was adequate to enable detection. The results obtained prove the efficacy of MALDI-MS for analyzing pathogenic bacteria in clinical samples. This article is part of a Special Issue entitled: Proteomics: The clinical link. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Development of a Test of Suprathreshold Acuity in Noise in Brazilian Portuguese: A New Method for Hearing Screening and Surveillance

    PubMed Central

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: “a hearing check is recommended” (red light), “a hearing check would be advisable” (yellow light), and “no hearing difficulties” (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention. PMID:25247181

  14. An exposure:activity profiling method for interpreting high-throughput screening data for estrogenic activity--proof of concept.

    PubMed

    Becker, Richard A; Friedman, Katie Paul; Simon, Ted W; Marty, M Sue; Patlewicz, Grace; Rowlands, J Craig

    2015-04-01

    Rapid high throughput in vitro screening (HTS) assays are now available for characterizing dose-responses in assays that have been selected for their sensitivity in detecting estrogen-related endpoints. For example, EPA's ToxCast™ program recently released endocrine assay results for more than 1800 substances and the interagency Tox21 consortium is in the process of releasing data for approximately 10,000 chemicals. But such activity measurements alone fall short for the purposes of priority setting or screening because the relevant exposure context is not considered. Here, we extend the method of exposure:activity profiling by calculating the exposure:activity ratios (EARs) using human exposure estimates and AC50 values for a range of chemicals tested in a suite of seven estrogenic assays in ToxCast™ and Tox21. To provide additional context, relative estrogenic exposure:activity quotients (REEAQ) were derived by comparing chemical-specific EARs to the EAR of the ubiquitous dietary phytoestrogen, genistein (GEN). Although the activity of a substance in HTS-endocrine assays is not a measure of health hazard or risk, understanding how such a dose compares to human exposures provides a valuable additional metric that can be used in decision-making; substances with small EARs and REEAQs would indicate low priority for further endocrine screening or testing. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Nontargeted Screening Method for Illegal Additives Based on Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry.

    PubMed

    Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang

    2016-09-06

    Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.

  16. Development of a test of suprathreshold acuity in noise in Brazilian Portuguese: a new method for hearing screening and surveillance.

    PubMed

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: "a hearing check is recommended" (red light), "a hearing check would be advisable" (yellow light), and "no hearing difficulties" (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  17. Assessing local capacity to expand rural breast cancer screening and patient navigation: An iterative mixed-method tool.

    PubMed

    Inrig, Stephen J; Higashi, Robin T; Tiro, Jasmin A; Argenbright, Keith E; Lee, Simon J Craddock

    2017-04-01

    Despite federal funding for breast cancer screening, fragmented infrastructure and limited organizational capacity hinder access to the full continuum of breast cancer screening and clinical follow-up procedures among rural-residing women. We proposed a regional hub-and-spoke model, partnering with local providers to expand access across North Texas. We describe development and application of an iterative, mixed-method tool to assess county capacity to conduct community outreach and/or patient navigation in a partnership model. Our tool combined publicly-available quantitative data with qualitative assessments during site visits and semi-structured interviews. Application of our tool resulted in shifts in capacity designation in 10 of 17 county partners: 8 implemented local outreach with hub navigation; 9 relied on the hub for both outreach and navigation. Key factors influencing capacity: (1) formal linkages between partner organizations; (2) inter-organizational relationships; (3) existing clinical service protocols; (4) underserved populations. Qualitative data elucidate how our tool captured these capacity changes. Our capacity assessment tool enabled the hub to establish partnerships with county organizations by tailoring support to local capacity and needs. Absent a vertically integrated provider network for preventive services in these rural counties, our tool facilitated a virtually integrated regional network to extend access to breast cancer screening to underserved women. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. SU-F-BRE-13: Replacing Pre-Treatment Phantom QA with 3D In-Vivo Portal Dosimetry for IMRT Breast Cancer

    SciTech Connect

    Stroom, J; Vieira, S; Greco, C

    Purpose: Pre-treatment QA of individual treatment plans requires costly linac time and physics effort. Starting with IMRT breast treatments, we aim to replace pre-treatment QA with in-vivo portal dosimetry. Methods: Our IMRT breast cancer plans are routinely measured using the ArcCheck device (SunNuclear). 2D-Gamma analysis is performed with 3%/3mm criteria and the percentage of points with gamma<1 (nG1) is calculated within the 50% isodose surface. Following AAPM recommendations, plans with nG1<90% are approved; others need further inspection and might be rejected. For this study, we used invivo portal dosimetry (IPD) to measure the 3D back-projected dose of the first threemore » fractions for IMRT breast plans. Patient setup was online corrected before for all measured fractions. To reduce patient related uncertainties, the three IPD results were averaged and 3D-gamma analysis was applied with abovementioned criteria . For a subset of patients, phantom portal dosimetry (PPD) was also performed on a slab phantom. Results: Forty consecutive breast patients with plans that fitted the EPID were analysed. The average difference between planned and IPD dose in the reference point was −0.7+/−1.6% (1SD). Variation in nG1 between the 3 invivo fractions was about 6% (1SD). The average nG1 for IPD was 89+/−6%, worse than ArcCheck (95+/−3%). This can be explained by patient related factors such as changes in anatomy and/or model deficiencies due to e.g. inhomogeneities. For the 20 cases with PPD, mean nG1 was equal to ArcCheck values, which indicates that the two systems are equally accurate. These data therefore suggest that proper criteria for 3D invivo verification of breast treatments should be nG1>80% instead of nG1>90%, which, for our breast cases, would result in 5% (2/40) further inspections. Conclusion: First-fraction in-vivo portal dosimetry using new gamma-evaluation criteria will replace phantom measurements in our institution, saving resources and

  19. Method for formation of high quality back contact with screen-printed local back surface field

    DOEpatents

    Rohatgi, Ajeet; Meemongkolkiat, Vichai

    2010-11-30

    A thin silicon solar cell having a back dielectric passivation and rear contact with local back surface field is described. Specifically, the solar cell may be fabricated from a crystalline silicon wafer having a thickness from 50 to 500 micrometers. A barrier layer and a dielectric layer are applied at least to the back surface of the silicon wafer to protect the silicon wafer from deformation when the rear contact is formed. At least one opening is made to the dielectric layer. An aluminum contact that provides a back surface field is formed in the opening and on the dielectric layer. The aluminum contact may be applied by screen printing an aluminum paste having from one to 12 atomic percent silicon and then applying a heat treatment at 750 degrees Celsius.

  20. Buccal swab, a minimally invasive method for the screening of oral cancer in active smokers

    NASA Astrophysics Data System (ADS)

    Suyatmi; Subiyantoro, P.; Indrakila, S.

    2018-05-01

    Smoking is the main risk factor for developing oral cancer. The previous study showed that there was a strong correlation between the length of smoking with the risk to develop oral cancer. Early detection of epithelial changes of oral mucosa will be a good prevention of the incidence of oral cancer among active smokers. This study evaluated the potential use of buccal swab for the screening of early signs of malignancy in active smokers. This study involved 80 participants including those who were smokers and non smokers. The buccal swab was conducted using sterile cytobrush. An epithelial smear was made from the buccal swab and stained with Papanicolaou’s technique. An cytomorphometric analysis was conducted by comparing the ratio of nuclear cell to cytoplasmic diameter (ND/CD) between the two groups. The mean of ND observed in this study were 8.963µ for active smokers and 7.991µ for non smokers groups. While the mean of CD were 58.249µ and 63.473µ for active smoker and non-smoker respectively. The mean of ND/CD ratio were 0.156 for active smokers and 0.129 for non smokers groups. This study detected a significant difference on the ND/CD ratio among active smokers vs non smokers (p<0.0001 95% CI = -0.040 – -0.014). In conclusion buccal swab could be a routine procedure to obtain sample for identification of changes in cells morphology to screen an early development of oral cancer.

  1. MOSFET dosimetry in-vivo at superficial and orthovoltage x-ray energies.

    PubMed

    Cheung, T; Butson, M J; Yu, P K N

    2003-06-01

    This note investigates in-vivo dosimetry using a Metal Oxide Semiconductor Field Effect Transistor (MOSFET) for radiotherapy treatment at superficial and orthovoltage x-ray energies. This was performed within one fraction of the patients treatment. Standard measurements along with energy response of the detector are given. Results showed that the MOSFET measurements in-vivo agreed with calculated results on average within +/- 5.6% over all superficial and orthovoltage energies. These variations were slightly larger than TLD results with variations between measured and calculated results being +/- 5.0% for the same patient measurements. The MOSFET device provides adequate in-vivo dosimetry for superficial and orthovoltage energy treatments with the accuracy of the measurements seeming to be relatively on par with TLD in our case. The MOSFET does have the advantage of returning a relatively immediate dosimetric result after irradiation.

  2. Solvent shift method for anti-precipitant screening of poorly soluble drugs using biorelevant medium and dimethyl sulfoxide.

    PubMed

    Yamashita, Taro; Ozaki, Shunsuke; Kushida, Ikuo

    2011-10-31

    96-well plate based anti-precipitant screening using bio-relevant medium FaSSIF (fasted-state simulated small intestinal fluid) is a useful technique for discovering anti-precipitants that maintain supersaturation of poorly soluble drugs. In a previous report, two disadvantages of the solvent evaporation method (solvent casting method) were mentioned: precipitation during the evaporation process and the use of volatile solvents to dissolve compounds. In this report, we propose a solvent shift method using DMSO (dimethyl sulfoxide). Initially, the drug substance was dissolved in DMSO at a high concentration and diluted with FaSSIF that contained anti-precipitants. To evaluate the validity of the method, itraconazole (ITZ) was used as the poorly soluble model drug. The solvent shift method resolved the disadvantages of the evaporation method, and AQOAT (HPMC-AS) was found as the most appropriate anti-precipitant for ITZ in a facile and expeditious manner when compared with the solvent evaporation method. In the large scale JP paddle method, AQOAT-based solid dispersion maintained a higher concentration than Tc-5Ew (HPMC)-based formulation; this result corresponded well with the small scale of the solvent shift method. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Microplate-Based Method for High-Throughput Screening (HTS) of Chromatographic Conditions Studies for Recombinant Protein Purification.

    PubMed

    Carvalho, Rimenys J; Cruz, Thayana A

    2018-01-01

    High-throughput screening (HTS) systems have emerged as important tools to provide fast and low cost evaluation of several conditions at once since it requires small quantities of material and sample volumes. These characteristics are extremely valuable for experiments with large number of variables enabling the application of design of experiments (DoE) strategies or simple experimental planning approaches. Once, the capacity of HTS systems to mimic chromatographic purification steps was established, several studies were performed successfully including scale down purification. Here, we propose a method for studying different purification conditions that can be used for any recombinant protein, including complex and glycosylated proteins, using low binding filter microplates.

  4. Interlaboratory validation of quantitative duplex real-time PCR method for screening analysis of genetically modified maize.

    PubMed

    Takabatake, Reona; Koiwa, Tomohiro; Kasahara, Masaki; Takashima, Kaori; Futo, Satoshi; Minegishi, Yasutaka; Akiyama, Hiroshi; Teshima, Reiko; Oguchi, Taichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2011-01-01

    To reduce the cost and time required to routinely perform the genetically modified organism (GMO) test, we developed a duplex quantitative real-time PCR method for a screening analysis simultaneously targeting an event-specific segment for GA21 and Cauliflower Mosaic Virus 35S promoter (P35S) segment [Oguchi et al., J. Food Hyg. Soc. Japan, 50, 117-125 (2009)]. To confirm the validity of the method, an interlaboratory collaborative study was conducted. In the collaborative study, conversion factors (Cfs), which are required to calculate the GMO amount (%), were first determined for two real-time PCR instruments, the ABI PRISM 7900HT and the ABI PRISM 7500. A blind test was then conducted. The limit of quantitation for both GA21 and P35S was estimated to be 0.5% or less. The trueness and precision were evaluated as the bias and reproducibility of the relative standard deviation (RSD(R)). The determined bias and RSD(R) were each less than 25%. We believe the developed method would be useful for the practical screening analysis of GM maize.

  5. Screening of a new cadmium hyperaccumulator, Galinsoga parviflora, from winter farmland weeds using the artificially high soil cadmium concentration method.

    PubMed

    Lin, Lijin; Jin, Qian; Liu, Yingjie; Ning, Bo; Liao, Ming'an; Luo, Li

    2014-11-01

    A new method, the artificially high soil cadmium (Cd) concentration method, was used to screen for Cd hyperaccumulators among winter farmland weeds. Galinsoga parviflora was the most promising remedial plant among 5 Cd accumulators or hyperaccumulators. In Cd concentration gradient experiments, as soil Cd concentration increased, root and shoot biomass decreased, and their Cd contents increased. In additional concentration gradient experiments, superoxide dismutase and peroxidase activities increased with soil Cd concentrations up to 75 mg kg(-1) , while expression of their isoenzymes strengthened. Catalase (CAT) activity declined and CAT isoenzyme expression weakened at soil Cd concentrations less than 50 mg kg(-1) . The maxima of Cd contents in shoots and roots were 137.63 mg kg(-1) and 105.70 mg kg(-1) , respectively, at 100 mg kg(-1) Cd in soil. The root and shoot bioconcentration factors exceeded 1.0, as did the translocation factor. In a field experiment, total extraction of Cd by shoots was 1.35 mg m(-2) to 1.43 mg m(-2) at soil Cd levels of 2.04 mg kg(-1) to 2.89 mg kg(-1) . Therefore, the artificially high soil Cd concentration method was effective for screening Cd hyperaccumulators. Galinsoga parviflora is a Cd hyperaccumulator that could be used to efficiently remediate Cd-contaminated farmland soil. © 2014 SETAC.

  6. Discovery of potent KIFC1 inhibitors using a method of integrated high-throughput synthesis and screening.

    PubMed

    Yang, Bin; Lamb, Michelle L; Zhang, Tao; Hennessy, Edward J; Grewal, Gurmit; Sha, Li; Zambrowski, Mark; Block, Michael H; Dowling, James E; Su, Nancy; Wu, Jiaquan; Deegan, Tracy; Mikule, Keith; Wang, Wenxian; Kaspera, Rüdiger; Chuaqui, Claudio; Chen, Huawei

    2014-12-11

    KIFC1 (HSET), a member of the kinesin-14 family of motor proteins, plays an essential role in centrosomal bundling in cancer cells, but its function is not required for normal diploid cell division. To explore the potential of KIFC1 as a therapeutic target for human cancers, a series of potent KIFC1 inhibitors featuring a phenylalanine scaffold was developed from hits identified through high-throughput screening (HTS). Optimization of the initial hits combined both design-synthesis-test cycles and an integrated high-throughput synthesis and biochemical screening method. An important aspect of this integrated method was the utilization of DMSO stock solutions of compounds registered in the corporate compound collection as synthetic reactants. Using this method, over 1500 compounds selected for structural diversity were quickly assembled in assay-ready 384-well plates and were directly tested after the necessary dilutions. Our efforts led to the discovery of a potent KIFC1 inhibitor, AZ82, which demonstrated the desired centrosome declustering mode of action in cell studies.

  7. TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors

    SciTech Connect

    Ford, E; Phillips, M; Bojechko, C

    Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo).